Installation

Add to my manuals
29 Pages

advertisement

Installation | Manualzz

TELDAT C/S/G

ROUTERS FAMILY

Installation Manual

Doc. Dm274-I Rev. 5.0

September, 2003

I Chapter. Router Installation.....................................................................I-1

I - 1.

Introduction...............................................................................I-1

I - 2.

Connections...............................................................................I-2

I - 2.1.

Power Source Connection ............................................I-3

I - 2.1.1.

Devices with internal power supply sources..........I-3

I - 2.2.

Data Connections .........................................................I-4

I - 2.2.1.

ADSL Connection..................................................I-7

I - 2.2.2.

ISDN Connection...................................................I-9

I - 2.2.3.

Antenna connection..............................................I-10

I - 2.2.4.

POS Specific Interface Connections....................I-10

I - 2.2.5.

Configuration connection.....................................I-11

I - 3.

Installing the SIM card............................................................I-12

I - 4.

Installation in rack...................................................................I-12

I - 5.

Meaning of the LEDs ..............................................................I-14

I - 6.

Microswitches programming ..................................................I-17

I - 6.1.1.

Procedure for ignoring the configuration.............I-17

II Chapter. Appendix..................................................................................II-19

II - 1.

Trouble shooting ....................................................................II-19

II - 2.

Software updating ..................................................................II-20

II - 3.

Connectors .............................................................................II-21

II - 3.1.

LAN Connector.........................................................II-21

II - 3.2.

DSL Connector..........................................................II-21

II - 3.3.

ISDN Connector........................................................II-21

II - 3.4.

DTE/DCE Connector................................................II-22

II - 3.5.

POS Connector..........................................................II-23

II - 3.6.

ANT Connector.........................................................II-23

II - 3.7.

Configuration Connector...........................................II-23

II - 4.

Technical Specifications........................................................II-24 i

The manufacturer reserves the right to make changes and improvements in the appropriate features in either software or hardware of this product, modifying the specifications of this manual without prior notice.

The images presented on the front and back panels of the devices are provided as an information guideline. Some small modification can exist in the actual device.

ii

I - Chapter.

Router Installation

I - 1. Introduction

The

TELDAT C/S/G

routers family is composed of a range of IP routers for general purposes with a wide application area: personal environments, SOHO/SME and corporative; they are perfectly adaptable to a wide variety of IP scenarios: from providing simultaneous access to Internet for private LAN users to the adaptation of teleprocess networks and SNA support and the support of POS (Point of Sale terminals – dataphones).

The

TELDAT C/S/G

family covers the access needs for ADSL (both over

PSTN and ISDN), SHDSL, GSM/GPRS, ISDN and serial line (connection to an external telephone modem, Frame Relay, X.25 etc.).

This manual is the installation and device connection guide.

Illustration 1.1: External aspect for the Teldat C/S/G routers (excepting C6)

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-1

Doc. Dm274-I

Rev. 5.0

Illustration 1.2: External aspect for the Teldat C6 routers

(with rack adaptors)

I - 2. Connections

BEFORE INSTALLING THE ROUTER PLEASE READ THE FOLLOWING

INSTRUCTIONS CAREFULLY

Workplace Conditions. Main Characteristics

Excessive cold and heat should be avoided, as should humidity and dust.

Direct exposure to sunlight should be avoided as well as other heat sources. The device should not be placed amongst papers, magazines or other elements that could hinder natural air circulation.

The device should not be placed very close to strong electromagnetic fields such as speakers, engines, etc.

Knocks and/or strong vibrations should be avoided during transport, operation and storage.

WARNING: Electric supply current, tele phone and communication cables are dangerous. To prevent electric shock while installing, moving or opening the device covers, cables should be disconnected and connected as follows:

To Connect

Turn the device’s power supply OFF

Check that the power supply is not connected to either the main electricity supply or the device

Connect all data cables

Connect the power supply to the device

Connect the power supply to the main electricity supply

Turn the switch ON

To Disconnect

Turn the switch OFF

Disconnect the power supply from the main electricity supply

Disconnect the power supply from the device

Disconnect the data cables

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-2

Doc. Dm274-I

Rev. 5.0

NOTE: In cases of devices with internal power supply sources, these are permanently connected to the devices and therefore the steps relative to the said connection should be omitted, as they are impossible to carry out.

I - 2.1. Power Source Connection

Power

ANT DSL LAN DTE ISDN

TERM

Illustration 1.3: Connection to the power supply

The

TELDAT C/S/G

routers family (except for the Teld at C6 model) is powered with an external AC/DC source. (For details, consult the appendix).

To connect the power source to the device, follow the steps listed in the earlier table: ensure that the switch is OFF (0) and the power supply is not connected to the main electricity supply; find the POWER plug, located on the rear panel of the device and plug it into the power source. You must take care that the grooves of the plug are correctly plugged in to the POWER source. These grooves on the plug prevent the incorrect insertion of this plug.

For subsequent connection of the power source to the main electricity supply, use the grounded cable provided for this purpose.

I - 2.1.1. Devices with internal power supply sources

To connect the power source to the device: check that the power switch in the

OFF position (0) and that the device is not connected to the main electricity supply; locate the power connector situated on the rear of the device and insert the power cable with the ground provided for this (the shape of the connector prevents incorrect insertion).

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-3

Doc. Dm274-I

Rev. 5.0

Illustration 1.4: Connecting the power with the internal source

To avoid electric shocks, residual current circulation and other unwanted effects, also affecting communications, the fo llowing is recommended:

It is highly recommended that all interconnected communication devices are plugged to THE SAME GROUNDED POWER OUTLET, which should at the same time be of good quality (lower than 10ohms).

Whether the workplace is provided with an uninterrupted power supply system (UPS), regulated supply or it is independent from the rest (such as lighting, etc.); it is highly recommended that all data devices should be connected to the same power source. This will avoid operating and premature aging problems of drivers and other components.

I - 2.2. Data Connections

The

TELDAT C/S/G

router family has the following connectors available.

Some of these connectors may not be available depending on the model:

LAN:

Ethernet Interface 10BaseT for LAN connection; a LED (LNK) is provided indicating the establishment of the physical level and an RxD LED indicating frame reception (excepting Teldat C6).

Available in all models (excepting models with switch).

ANT DSL LAN

DTE

ISDN

Power

TERM

Illustration 1.5: LAN Connector, LNK led and RxD led

Illustration 1.6: LED LINK and LAN connector in the Teldat C6 model

SWITCH:

4 port switch 10/100BaseT with automatic MDI/MDIX for local area network

(LAN) connection: this has a 100 LED indicating connection at 100 Mbps, and a 10

LED indicating connection at 10 Mbps.

Please pay close attention to the labeling. This is important in order to avoid confusing the switch with the four asynchronous ports.

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-4

Doc. Dm274-I

Rev. 5.0

Available depending on model.

Illustration 1.7: Switch LAN Connector, LEDs 100 and LEDs 10

DTE / DCE:

Multistandard serial interface for connection to an external modem, POS or for connection to an X.25 type WAN, Frame Relay, PPP, etc. (among other functions).

Requires an insertable driver (V.24, V.35, V.36, X.21) and software license for operating purposes.

ANT DSL LAN DTE ISDN

Power

TERM

Illustration 1.8: DTE/DCE Connector

Illustration 1.9: DTE/DCE Connector in the Teldat C6 model

DSL: xDSL interface (ADSL over PSTN, ADSL over ISDN, SHDSL, etc.)

In cases of model C6, only ADSL over PSTN.

Requires an xDSL plug-in card and software license for operating purposes.

ANT DSL LAN

DTE

ISDN

Power

TERM

Illustration 1.10: ADSL Connector

Illustration 1.11: ADSL Connector in the Teldat C6 model

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-5

Doc. Dm274-I

Rev. 5.0

ISDN:

Basic ISDN 2B+D interface; a switch (TERM) is available in order to introduce the S bus termination load.

Requires a software license for operating purposes.

ANT DSL LAN DTE ISDN

Power

TERM

Illustration 1.12: ISDN Connector and TERM pushbutton

Illustration 1.13: ISDN Connector and TERM pushbutton in the Teldat C6 model

ANT.:

RF antenna connector.

Requires an xDSL plug-in card and software license for operating purposes.

ANT DSL LAN

DTE

ISDN

Power

TERM

Illustration 1.14: Connector for the RF antenna

ASYNCHRONOUS SERIAL INTERFACES:

Asynchronous serial interfaces for connecting modems -point of sale terminals

(POS), etc.

Available depending on model.

Illustration 1.15: Specific asynchronous POS connectors

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-6

Doc. Dm274-I

Rev. 5.0

I - 2.2.1. ADSL Connection

The ADSL interface has a female RJ11 connector with 4 wires of which the

central pair is used for data transmission/reception.

In order for connection you can use the telephone cable with male

RJ11connectors that are provided with the device.

The splitter

The Full Rate ADSL (ITU G.dmt or G. 922.1) operating mode uses a higher transmission capacity which does not allow the use of telephones directly connected to the same line; it is necessary to use a mechanism known as “splitter” in charge of separating the band frequencies for voice telephony from those used for the ADSL connection for transmission of data, in this way avoiding interferences between the telephone service and ADSL service and vice-versa.

A typical installation with a splitter is shown in Illustration 1.16.

The micro-filter

The G. Lite (ITU G.922.2) operating mode uses reduced transmission power which permits the use of telephones directly connected to the same line by using a device known as a “micro -filter”. This device ensures that the ADSL signal does not reach the telephone and that undesired signals generated by the telephone do not interfere with the ADSL signal.

A typical installation with a splitter is shown in Illustration 1.17.

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-7

Doc. Dm274-I

Rev. 5.0

ADSL PHONE

SPLITTER

POTS

Telephone Network

Illustration 1.16: ADSL installation with a splitter

Micro-filter

Micro-filter

Telephone Network

Illustration 1.17: ADSL installation with splitter

In cases of ADSL over ISDN, the above information for operations over PSTN is applicable. However you must bear in mind that the frequency bands used are

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-8

Doc. Dm274-I

Rev. 5.0

different and therefore you must use splitters and microfilters specifically for ADSL over ISDN.

I - 2.2.2. ISDN Connection

The ISDN interface has a female RJ45 connector in order to connect to the S bus with 4 wires that arrives from the ISDN (NT1 or TR1) network terminator.

For this connectio n you can use the cable with male RJ45 connectors, provided with the device.

Passive-Bus termination resistors

The

TELDAT C/S/G

has a pushbutton (labeled TERM.) permitting you to connect the BUS-S termination resistors. It is very important that the placement of the termination resistors is correct. If the location is not correct, this can cause errors in data (or voice), especially if the bus “S” is long.

Single or last terminal in the ISDN “S” bus

The TERM. pushbutton must be in the ON position if the router is the only element connected to the network (NT1, TR1, etc.) terminator or it is the last in the

ISDN “S” bus. By default, the device is configured in this position.

FAX

S BUS (4 wires)

NT1 / TR1

U Interface

(2 wires)

ISDN

ROUTER TELDAT C

Telephone

Illustration 1.18: Single or last terminal

Intermediate position in the ISDN “S” bus

The TERM pushbutton must be in the OFF position if the router occupies an intermediate position in the ISDN “S” bus.

FAX

S BUS (4 wires)

NT1 / TR1

U Interface

(2 wires)

ISDN

ROUTER TELDAT C

Telephone

Illustration 1.19. Intermediate position in the bus

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-9

Doc. Dm274-I

Rev. 5.0

I - 2.2.3. Antenna connection

The

TELDAT G

routers have a connector to connect an external antenna which will improve the quality of the signal received and transmitted by the GSM/GPRS module.

I - 2.2.4. POS Specific Interface Connections

In order to connect a POS to the router (in general, although this depends on the type of POS connector) you must use a male -male pin -to-pin RJ45 to RJ45 cable.

The router interfaces behave in DCE mode.

Illustration 1.20: POSs Installation

Depending on the manufacturer of the sale terminals , you may need specific cables or use the internal jumpers which permit you to short circuit the appropriate

DSR and DTR signals, when the DTR flow control signal is not provided by the terminal.

The jumpers are located next to the POS connectors (you will need to open the device’s chassis in order to access the mentioned jumpers) and these are labeled as

P16, P15, P14 and P13, corresponding respectively to the T1, T2, T3 and T4 connectors.

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-10

Doc. Dm274-I

Rev. 5.0

I - 2.2.5. Configuration connection

The

TELDAT C/S/G

routers have a female RJ45 connector in the front panel referred to as “Conf.” which provides access to the device’s local console. For configuration, you must connect to the “Conf.” port to an asynchronous terminal (or to a PC with terminal emulation).

Configuration

Port

Illustration 1.21: Configuration connector

Illustration 1.22: Configuration connector in the Teldat C6 model

The configuration of the terminal must be:

- Speed: 9600 bps

- Eight data bits

- One stop bit

- No bit parity

- No type of flow control

The connection to the configuration port can be carried out with RJ45 cable connectors provided with the device together with the Female RJ45-Female DB9 adapter, also provided with the device or with the serial cable with DB9 male/DB9 female connectors in the case of the Teldat C6 model. In cases where the terminal has

DB25 connectors, you must use an additional adapter.

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-11

Doc. Dm274-I

Rev. 5.0

Configuration

Port

TERMINAL

RJ45F-DB9F

Adapter

Illustration 1.23: Connection for Configuration

I - 3. Installing the SIM card

The

TELDAT G

models have a GSM/GPRS interface which requires a SIM card to be inserted in order to function.

Please see the plug-in cards installation manual for Teldat Compact Modular routers for further instructions on how to insert the SIM.

I - 4. Installation in rack

In order to install the

TELDAT C

C6 model router in a 19-inch rack, you require two plastic strips as can be seen in the figure. The strips and the associated screws are not included in the basic packet and need to be acquired separately.

Both s trips are attached to the device through four screws, two at each side as shown in the Illustration 1.24.

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-12

Doc. Dm274-I

Rev. 5.0

Illustration 1.24: Rack adaptation

The spaces for the screws leave the factory protected by covers. These can be removed by using a sharp tool (such as a small flat screwdriver). We recommend removing the upper cover in order to carry this out more easily.

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-13

Doc. Dm274-I

Rev. 5.0

I - 5. Meaning of the LEDs

Teldat

Access Router

o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o

ISDN ISDN

S LAN DSL/RF DTE B2 A B

ON

B1

CONF.

o o

DTE

A

B

Illustration 1.25. Front panel of the Teldat C routers (without specific POS asynchronous interfaces or switch)

ON

S

LAN

DSL / RF

ISDN

B1

ISDN

B2

POWER-ON INDICATOR, It lights when connected to the power.

Router operation

OFF:

GREEN

:

YELLOW

:

System off.

System initialized and operating.

System with established Telnet session.

Ethernet LAN Interface:

OFF:

RED

:

LAN interface does not send data.

ERROR: Interface not available either because it is not enabled or has failed test.

YELLOW

:

GREEN

:

Interface initialization in progress.

Interface available.

Flashing: “heartbeat”.

DSL or RF Interface

OFF:

RED

:

YELLOW

:

GREEN

:

Interface not available (not support).

Interface is not established, without data connection. xDSL or RF connecting. xDSL / RF communication established.

Flashing : Traffic through the interface.

Multistandard serial interface

OFF:

Port not initialized.

RED

:

YELLOW

:

GREEN

:

Port initialized.

In process of establishing link.

Communication established.

ISDN Interface Channel B1:

OFF:

Physical level unavailable.

RED

:

YELLOW

:

GREEN

:

ERROR: Line errors (physical level) or call in progress.

Physical level established.

Call established through B1 channel (B1 channel from the network).

Light flashing green / off: Switched channel.

Light flashing green / yellow: Permanent channel.

ISDN Interface Channel B2:

OFF:

RED

:

YELLOW

:

GREEN

:

Physical level unavailable.

ERROR: Line errors (physical level) or call in progress.

Physical level established.

Call established through B2 channel (B2 channel from the network

Light flashing green / off: Switched channel.

Light flashing green / yellow: Permanent channel.

Reserved

Reserved

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-14

Doc. Dm274-I

Rev. 5.0

Teldat

Access Router

o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o

S LAN DSL/RF ISDN T1 T2 T3 T4

ON

CONF.

o o

Illustration 1.26 Front panel of the Teldat C/S/G routers

(with specific POS asynchronous interfaces)

ON

S

LAN

DSL / RF

ISDN

T1, T2

T3, T4

POWER-ON INDICATOR. It lights up when connected to the power.

Router operations

OFF:

GREEN:

YELLOW:

System off.

System initialized and operating.

System with established Telnet session.

Ethernet LAN Interface:

OFF:

RED:

LAN interface does not send data.

ERROR: Interface not available either because it is not enabled or has failed test.

YELLOW:

GREEN:

Interface initialization in process.

Interface available.

Flashing: Maintenance frame.

ADSL Interface:

OFF:

RED:

YELLOW:

GREEN:

ISDN Interface:

Off:

RED

:

YELLOW:

GREEN:

Interface not available (not support).

Interface is not established, without data connection. xDSL / RF Connecting. xDSL / RF communication established.

Flashing: Traffic through the interface.

Physical level unavailable.

ERROR: Errors in line (physical level) or call in progress.

Physical level established.

Call established.

POS Interfaces:

OFF:

RED

:

YELLOW

:

GREEN

:

Port not initialized.

Port initialized in stand-by.

In process of establishing link.

Communication established.

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-15

Doc. Dm274-I

Rev. 5.0

Teldat

Access Router

o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o

ON

S LAN 1 LAN 2 LAN 3 LAN 4 DSL / RF

ISDN

B1

ISDN

B2

CONF.

ON

S

LANx

DSL / RF

ISDN

B1

ISDN

B2

Illustration 1.27. Teldat C/S/G front panel with switch

Device ON switch. This lights up on being connected to the power supply.

Router operation

OFF:

GREEN

:

YELLOW

:

System stopped.

System up and running.

System with Telnet session established.

Ethernet LAN Interface:

OFF:

LAN interface does not send data.

RED

:

YELLOW

:

GREEN

:

ERROR: Interface unavailable due to not being enabled or test failure.

Interface initialization process.

Interface available.

Intermittent: “heartbeat”.

DSL or RF Interface

OFF:

RED

:

YELLOW

:

GREEN

:

Interface unavailable (not supported).

Interface not established, without data connection.

Intermittent: in cases of xDSL, problems with the interface firmware. xDSL or RF is connecting. xDSL / RF communication established.

Intermittent: Traffic through the interface.

ISDN interface B1 channel:

OFF:

Physical layer unavailable.

RED

:

YELLOW

:

GREEN

:

ERROR: Line errors (physical layer) or call in progress.

Physical layer established.

Call established through B1 channel (network B1 channel).

Intermittent green / off: Switch channel.

Intermittent green / yellow: Permanent channel.

ISDN interface B2 channel:

OFF:

RED

:

YELLOW

GREEN

:

:

Physical layer unavailable.

ERROR: Line errors (physical layer) or call in progress.

Physical layer established.

Call established through B2 channel (network B2 channel).

Intermittent green / off: Switch channel.

Intermittent green / yellow: Permanent channel.

In the case of the Teldat C6 model, the meaning of the LEDs coincides with that described for the Teldat C routers without specific asynchronous interfaces with the exception that this has two DSL LEDs and does not have the B LED.

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-16

Doc. Dm274-I

Rev. 5.0

I - 6. Microswitches programming

A row of microswitches that activate test, software loading functions, etc., can be found on the lower part of the

TELDAT C /S/G

routers. These should not be handled by the user unless it is necessary to re establish the default configurations.

All the microswitches must be in the OFF position to ensure it is functioning correctly.

I - 6.1.1. Procedure for ignoring the configuration

This procedure is applied if you have to reject the whole configuration of the device, for example, you cannot remember the password for it.

The procedure is as follows:

Turn off the device through the ON/OFF switch.

Using a screwdriver move the microswitch (number 5) to the ON position.

Turn the device on with the ON/OFF switch.

When the device is switched, on a message similar to the one shown below will appear on the configuration console:

**************************************************

******************* Router Teldat ****************

**************************************************

BOOT CODE VERSION: 1.1.0B

STARTING FROM FLASH

BOOT 22/02/00 11:51

GZIP 18/02/00 19:02

BIOS CODE DUMP.........

BIOS DATA DUMP..

End of BIOS dump

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-17

Doc. Dm274-I

Rev. 5.0

=======================================================

ROUTER TELDAT C (c)Teldat

=======================================================

Bios's version: 1.1.0B

CPU: MPC860 CLK=49152 KHz BUSCLK=49152 KHz

Date: 29/02/00, Wednesday Time: 15:34:34

SDRAM size: 16 Megabytes

SIMM 0: 16 Megabytes (detected)

Caches: ON Write-Back

FLASH: 8 Mb.

NVRAM: 128 Kb.

EEPROM: 2048 Bytes.

WAN: DTE

ADSL

UTOPIA

LAN SCC1

Current production date: 00 06

Current software license: 20 4

Current serial number: 359/00011

........

TRYING APP CODE DUMP

(CONFIGURED)

B0080000............................................

APP DATA DUMP....................

Running application

Default configuration used

Initializing

Teldat (c)1996-2000

Modem model TELDAT C 20 4 CPU M80860 S/N: 359/00011

1 LAN, 1 WAN Line , 0 ISDN Lines, 1 ADSL Line

*

On reaching this point, you can set microswitch 5 in the OFF position (it is not necessary to turn off the device), in this way, the next time you restart the device, the saved configuration is respected.

TELDAT C/S/G ROUTERS FAMILY

- Installation

I-18

Doc. Dm274-I

Rev. 5.0

II - Chapter.

Appendix

II - 1. Trouble shooting

Below, you will find a table that will aid you in solving problems during the installation of the device. If you cannot resolve the problem, consult your distributor for additional information.

Problem

Solution

None of the LEDs lights up on the device.

Check the power supply to the device (power source, ON/OFF switch, main power outlet).

The S LED does not light up. Check that all the microswitches are in the OFF position.

The LAN LED never lights up in green.

Check that the LED following the LINK is ON; if this is not the case, check the Ethernet cable and the connection to the network (you may need a crossover cable).

The DSL LED never lights up in green.

If the device has an xDSL interface available, check the connection to the telephone network or to the splitter and make sure that the telephone line you are connected to supports xDSL service.

The DSL LED persistently flashes in red.

If your device has an xDSL interface, check that the necessary firmware has been loaded for the said interface.

The DTE LED never lights up green. If the device has a DTE/DCE interface available, make sure the cable being used is the correct one, the driver is inserted correctly

(DTE or DCE), and the configuration is correct

(speed, protocol, etc).

The ISDN LEDS never light up in yellow or green.

If the device has an ISDN interface available, check that the connection to the bus is correct and the termination switch from the S bus is in the correct position.

TELDAT C/S/G ROUTERS FAMILY

- Appendix

II-19

Doc. Dm274-I

Rev. 5.0

Problem Solution

The LEDS indicate the interfaces are established but there is no connectivity at the data levels.

Check the configuration (routes, IP addresses, ATM VPIs/VCIs, encapsulated

ATM, serial interface speed, etc).

The “Ti” LED is red after trying to make a transaction.

The device is not receiving data from the

POS connected to the i port. Check the speed configured in the interface and the cable connecting the device to the POS.

The “Ti” LED is yellow after trying to make a transaction and does not pass to green.

IP connectivity has not been achieved between the router and the host. Check the configuration and if the problem persists consult your supplier.

II - 2. Software updating

The

TELDAT C/S/G

routers can be updated to the new releases. Please consult your distributor for new releases.

There are various ways to update a Teldat router: please see the software upgrading manual for further information.

The software required to update the Teldat routers is provided in a format known as distribution. This consists of a single file containing all the necessary files to update your device as well as detailed information on the content.

TELDAT C/S/G ROUTERS FAMILY

- Appendix

II-20

Doc. Dm274-I

Rev. 5.0

II - 3. Connectors

II - 3.1. LAN Connector

RJ45 LAN

RJ45 PIN

5

6

7

8

1

2

3

4

LAN

Tx+(input)

Tx -(input)

Rx+(output)

--

--

Rx -(output)

--

--

II - 3.2. DSL Connector

RJ11 ADSL

RJ11 PIN

1

2

3

4

DSL

Joined to 2

Line

Line

Joined to 3

II - 3.3. ISDN Connector

RJ45 ISDN

RJ45 PIN

5

6

7

8

1

2

3

4

ISDN

--

--

Tx+ (output)

Rx+(input)

Rx -(input)

Tx -(output)

--

--

TELDAT C/S/G ROUTERS FAMILY

- Appendix

II-21

Doc. Dm274-I

Rev. 5.0

II - 3.4. DTE/DCE Connector

DB25 DTE/DCE

DB25

Connector

Pin

18

19

20

24

7

8

5

6

3

4

1

2

9

14

15

16

17

V.24

STANDARD

V.35 X.21

Signal ITU Signal V.35 Signal DB15

Ground 101

TxD 103

RxD 104

RTS 105

CTS 106

DSR 107

GND 102

DCD 109

TxC 114

RxC 115

Ground

TxD (A)

RxD (A)

RTS

CTS

DSR

GND

DCD

TxD (B)

TxC (A)

D

E

B

F

A Ground

P TxD (A)

R RxD (A)

C CONT(B)

ExTxC (B) W

GND

S TxD (B)

Y IND(A)

RxD (B)

RxC (A)

T

V

RxD (B)

CLK(A)

TxC (B)

RxC (B)

AA

X

IND(B)

CLK(B)

DTR 108

ExTxC 113

DTR

ExTxC (A)

H CONT(A)

U

12

13

3

8

1

2

4

10

9

5

11

6

TELDAT C/S/G ROUTERS FAMILY

- Appendix

II-22

Doc. Dm274-I

Rev. 5.0

II - 3.5. POS Connector

RJ45 TPV

II - 3.6. ANT Connector

PIN

Internal

External

5

6

7

8

1

2

3

4

RJ45 PIN POS

DCE

TxD (input)

CTS (output)

RTS(input)

GND

DTR (input)

DSR (output)

--

RxD (output)

ANT

RF in/out

GND

II - 3.7. Configuration Connector

RJ45 CONFIGURATION

RJ45 PIN

5

6

7

8

1

2

3

4

CONF

--

RxD

--

GND

--

GND

TxD

--

TELDAT C/S/G ROUTERS FAMILY

- Appendix

II-23

Doc. Dm274-I

Rev. 5.0

DB9 CONFIGURATION

RJ45 PIN

5

6

7

8

1

2

3

4

CONF

--

RxD

TxD

--

GND

--

--

--

II - 4. Technical Specifications

Hardware Architecture

PROCESSORS

MEMORY

STORAGE UNIT

Motorola MPC8xx (Different versions: SAR, T, EN...) 50 MHz

32/64 Mbytes in SDRAM.

FLASH Memory (4 Mbytes / 8 Mbytes)

EEPROM 2 Kbytes, NVRAM 128 Kbytes.

LAN Interface

PROTOCOLS

SPEED

CONNECTOR

DTE/DCE* Interface

PROTOCOLS

INTERFACES

SPEED

CONNECTOR

DSL* Interface

STANDARDS

SPEED

CONNECTOR

Ethernet (802.3).

10 Mbps (10BaseT) or SWITCH* 10/100 Mbps (BaseT).

RJ45 female.

FRAME RELAY, X.25, PPP, SDLC, X.28, POS-DATAPHONE

Insertable drivers V.24 / V.35 / V.36 / X.21 DTE/DCE.

200 to 2048 Kbps.

DB25 Female

Please see our manual on plug-in cards.

Please see our manual on plug-in cards.

RJ11 female.

TELDAT C/S/G ROUTERS FAMILY

- Appendix

II-24

Doc. Dm274-I

Rev. 5.0

RF Interface*

STANDARDS

SPEED

CONECTOR

ISDN* Interface

ACCESS

SPEED

CONNECTOR

Please see our manual on plug-in cards

Please see our manual on plug-in cards

Please see our manual on plug-in cards

Basic 2B+D

2 x 64 Kbps (B channels)

RJ45 female

POS* Interface

CONNECTOR

INTERFACES

SPEED

PROTOCOLS

* According to the version

Config Interface

LOCAL TERMINAL

CONNECTOR

RJ45 female

V.24 (RS232-C) DCE

300 to 64000 bps

Dataphone DOV, PPP

V.24 9.600-8-N-1- without flow control.

RJ45 female, located on the front panel of the device.

DB9 female on the rear part of the C6 model.

Power Source

INPUT VOLTAGE

OUTPUT VOLTAGE

MAXIMUM POWER

+5V,+15V,-15V DC.

2000 mA (to +5V DC) and 200 mA (to +15V, -15V DC).

20 W.

External power supply

INPUT VOLTAGE

INPUT CURRENT

INPUT FREQUENCY

MAXIMUM POWER

100-240V AC

600 mA

50-60 Hz

45 VA

TELDAT C/S/G ROUTERS FAMILY

- Appendix

II-25

Doc. Dm274-I

Rev. 5.0

Teldat C6 model Power Source

INPUT VOLTAGE

INPUT CURRENT

INPUT FREQUENCY

MAXIMUM POWER

100-240V AC

1400 mA

47-63 Hz

45 W

Dimensions and weight

TYPE

LENGTH x WIDTH x HEIGHT

WEIGHT

Desktop

220 x 220 x 30 mm.

0.9 Kg.

Teldat C6 model dimensions and weight

TYPE

LENGTH x WIDTH x HEIGHT

WEIGHT

Desktop box.

310 x 415 x 43 mm

3.25 Kg.

Environmental Specifications

AMBIENT TEMPERATURE

RELATIVE HUMDITY

On: 5º to 45ºC.

On: 8% to 85%.

Off: -20º to 60ºC.

Off: 5% to 90%.

TELDAT C/S/G ROUTERS FAMILY

- Appendix

II-26

Doc. Dm274-I

Rev. 5.0

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement