PHANTOM Battery Unit
PHANTOM Battery Unit
Recessed cabinet,
Emmergency Lighting System
Features
Fully automatic operation: the unit door opens upon
loss of AC power and closes when the power is back
or at the end of battery discharge
Input: Standard AC input 120/347Vac, 0.25/0.09
Amps; optional 120/277Vac
Battery: maintenance-free, sealed Lead-acid battery,
with a 10-year design life
Typical Specification
Charger: micro-controller driven, temperature
compensated, high-precision, fast recharge
Back-box (self-powered unit): made of heavy-duty,
galvanized steel
Remote fixture: version available in 12Vdc or 24Vdc;
no back box, no AC wires are required
Certification: CSA C22.2 No.141
Made in Canada
Supply and install Lumacell Series Phantom. The unit
shall be designed to be concealed in walls or ceilings
with a cavity, including T-bar suspended ceilings. Bar
hanger brackets shall be provided with the self-powered
unit. The equipment shall consist of a metal back box
containing the batteries, the lamp assembly and a
charging circuitry. The back box shall be constructed of
heavy-duty galvanized steel. The unit components:
battery assembly, charger circuitry and lamp assembly
shall have a modular design and come standard with
quick connect plugs for easy installation in the back box.
The unit equipment shall be completely concealed in the
wall or ceiling during normal power conditions. Upon a
power failure the unit will expose the emergency heads
by rotating its door 180° and then power the lamps. At
the restoration of the AC power or at the end of the
battery discharge, the lamps will turn off and the unit will
retract the heads in the wall (ceiling) by rotating the door
by 180°. Under normal conditions, the only visible parts
of the unit shall be the flat door and trim plate, coated
with a high-quality off-white finish that can be
customized on site with paint or other suitable wall
covering. The light source shall be 12V MR16 halogen
lamps of specified wattage and light output. The unit
shall supply the rated load for a minimum of 30 minutes
or until the battery is discharged to 87 ½% of its nominal
voltage (whichever duration is longer). The charger
circuitry shall utilize a micro-controller IC that samples
the battery in relation to the ambient temperature, state
of charge, and input voltage fluctuations. The charger
shall be current limited, temperature compensated,
short-circuit proof, and reverse-polarity protected. The
circuit will charge in accordance with the CSA C22.2 –
141 requirements. The unit shall be furnished with a
recessed, illuminated push button serving as test switch
and status indicator light.
Auto-test and diagnostic: the unit will come complete
with the LumacellTM series of auto-test micro-controller
circuitry that will ensure the equipment readiness and
reliability by continuously monitoring every critical
function of the unit. If a problem occurs, the pilot light
located on the front of the unit, will change color from
green to red and will flash indicating a fault. A detailed
diagnostic legend shall be available on the door back
side and shall provide fault identification (battery,
charger circuitry, lamps) for the maintenance personnel.
The auto-test shall simulate a power loss for one minute
monthly, 10 minutes every sixth months, and a full 30minute test every 12 months.
The equipment shall be Lumacell model: __________.
In the same family...
PHANTOM
Remote Fixtures
114
p. 172 - 173
www.lumacell.com
Project/Location
Date
Contractor
Prepared by
LUMACELL Model
Opened
Closed
PHANTOM SERIES
Dimensions
9 1/8“ (23.2 cm)
3 3/8“ (8.7 cm)
7 7/8“ (19.9 cm)
Power Consumption
and Unit Rating
Model
PH75
7“ (17.8 cm)
23 7/8“ (60.5 cm)
PH150
AC Specs
120/347
Vac
0.25/0.09
Amp
Wattage Capacity
30min 1h00 1h30 2h00 4h00
75
40
30
24
15
150
80
60
48
30
Replacement Lamps
Model
Lamp Type
Voltage-Wattage
580.0080-L
580.0064-L
580.0083-L
580.0076-L
580.0068-L
580.0090-L
580.0089-L
580.0084-L
580.0070-L
580.0077-L
580.0078-L
MR16 12W Flood
MR16 20W Flood
MR16 35W Flood
MR16 50W Flood
MR16 IR* 20W Flood
MR16 IR* 35W Flood
MR16 IR* 50W Flood
MR16
MR16
MR16
MR16
12V-12W
12V-20W
12V-35W
12V-50W
12V-20W
12V-35W
12V-50W
24V-35W
24V-12W
24V-20W
24V-50W
* High-output (H).
See the complete list p. 196 to 199.
Ordering Information
Series
PH
Unit Capacity
75= 12V, 75W
150= 12V, 150W
Lamp Wattage
12W= 2x 12 watts MR16
20W= 2x 20 watts MR16
35W= 2x 35 watts MR16
50W= 2x 50 watts MR16
20WH= 2x 20 watts MR16,
High lumen-output lamp
35WH= 2x 35 watts MR16,
High lumen-output lamp
50WH= 2x 50 watts MR16,
High lumen-output lamp
AC Voltage
Options
Blank= 120/347Vac
ZC= 120/277Vac
AT= Auto-Test
ATN= Auto-Test,
non-audible
T3= Time delay
(15 minutes)
EXAMPLE: PH15012WAT