AquaCal TC1000 TropiCool® Manual 20 Pages
Aquacal TC500 is an advanced chiller system designed to provide efficient and precise temperature control for pools or spas. It features a user-friendly control panel with a digital display, allowing you to easily set and monitor the desired water temperature. Choose between Celsius or Fahrenheit for temperature display, and enable the display lock to prevent unintended setting changes. The TC500 also includes a user lock option with a passcode to restrict unauthorized access to temperature adjustments.
advertisement
AquaCal
®
Operation Manual
Important
Read this document before operating / installing this product
For additional product manuals and operation / installation procedures, please visit www.AquaCal.com
LTM0884 REV 1
Table of Contents
Section 1 - Contacting AquaCal AutoPilot, Inc.
3.10 Selecting Celsius or Fahrenheit
3.11 User Lock Option (Enable)
3.12 User Lock Option (Entering Pass Code)
3.13 User Lock Option (Disable)
4.1.c Irrigation and Storm Run-Off
6.1 Identifying Model Specifications
6.2 Initial Cooling Recommendations
i
SECTION 1 - CONTACTING AQUACAL AUTOPILOT, INC.
For further assistance, please contact the installing dealer or contact AquaCal AutoPilot, Inc. for a service
"Identifying Model Specifications" on page 17.
Website www.AquaCal.com
Request Service Online
Phone
Hours www.AquaCal.com/request-heat-pump-service/
(1) 727-823-5642
8-5 pm, Eastern M-F
SECTION 2 - SAFETY
l l l
For personal safety, and to avoid damage to equipment, follow all safety instructions displayed on the equipment and within this manual. Repair and service of chiller must be performed by an authorized service center.
Warranties may be voided if the equipment has been improperly installed, maintained or serviced.
If service is deemed necessary, please contact the installing dealer. Or contact AquaCal ® your area.
See "Contacting AquaCal AutoPilot, Inc." on page 1.
for a service partner in
SAFETY SIGNALS
Throughout this document, safety signals have been placed where particular attention is required.
WARNING - signals relate to personal safety.
CAUTION - signals promote avoiding damage to the equipment.
When installing and using your chiller basic safety precautions must always be followed, including the following: l l l l l l
WARNING - Failure to heed the following may result in injury or death.
Installation and repairs must be performed by a qualified technician.
The chiller contains refrigerant under pressure. Repairs to the refrigerant circuit must not be attempted by untrained and / or unqualified individuals. Service must be performed only by qualified HVAC technicians.
Recover refrigerant before opening the system.
The chiller utilizes high voltage and rotating equipment. Use caution when servicing.
Electrical installation and service should be performed by a Licensed Electrician only.
Improper water chemistry can present a serious health hazard. To avoid possible hazards, maintain pool / spa water per standards detailed in this document.
Prolonged immersion in water colder than normal body temperature may cause a condition known as
Hypothermia. The symptoms of Hypothermia include shivering (although as hypothermia worsens, shivering stops), clumsiness or lack of coordination, slurred speech or mumbling, confusion and poor decision-making, drowsiness or low energy, lack of concern about personal welfare, progressive loss of consciousness, weak pulse and slow or shallow breathing. In addition, persons having an adverse medical history, or pregnant women, should consult a physician before immersing in a cold body of water. Children and the extreme elderly should be supervised by a responsible adult.
l l
CAUTION - Failure to heed the following may result in equipment damage.
Maintain proper water chemistry in order to avoid damage to pump, filter, pool shell, etc.
Water flow exceeding maximum flow rate requires a bypass. Damage due to excessive water flow will void warranty.
SAVE THESE INSTRUCTIONS
Page - 1
SECTION 3 - OPERATION
3.1 Energizing Chiller
Turn power on at external fuse box or breaker disconnect.
l l
Controller performs a lamp test.
The display reads 888.
l
Controller then displays as normal.
3.2 Display Lock
The chiller has a display lock to protect against inadvertent setting changes. To activate display and controls, slide finger across the controls as shown from left to right.
l
The code UnL will briefly appear, then the set temperature l or mode will display.
This is different than a user-lock which requires a pass code.
See "User Lock Option (Enable)" on page 5.
3.3 Control Panel
The following information outlines the operation for a standard installation.
Control Panel
3.4 Buttons
Buttons
Display Lock
Pool / Spa
Up Arrow
Down Arrow
Mode
3.5 Indicator Lights
Indicators
Pool
Spa
Cooling
Water Temp
Desired Temp
Page - 2
Description
Sliding your finger across the buttons from left to right will temporarily disable the display lock.
Select either the pool or the spa thermostat.
Used to increase temperature set point and navigate though menu options.
Used to decrease temperature set point and navigate though menu options.
Select chiller's operating mode.
Description
The Chiller is referencing the pool thermostat.
The Chiller is referencing the spa thermostat.
Indicates the unit is cooling the water.
Please note - the compressor must be operating before this light will illuminate.
Indicates current water temperature.
Indicates temperature set point is displayed. This is displayed when "UP" or "DOWN" is selected.
3.6 Display
75
FLO
OFF
888
CF1
Display Description
The chiller is on and displaying the current water temperature. In this example 75° F is displayed.
No water flow is detected. The filter pump is off or chiller is not receiving correct water flow.
The chiller has been turned off via the mode selector button or the temperature set point has been lowered below 45° F.
The control program is initializing. This displays only as power is applied to the chiller. The program version number will then be displayed.
Select water temperature format (in either Celsius or
Fahrenheit).
ULC
ELC
Enable chiller lockout feature.
Select passcode to lock the keyboard.
LOC
This is a Service Entry Point (not intended for use by the owner). The LOC code permits service personnel to enter a factory passcode to access adjustable calibration and site dependent setup parameters. Service adjustments are available to authorized installation and service personnel, only.
3.7 Factory Defaults
Certain programming options have been preset at the factory. These options can be overwritten for sitespecific conditions.
l l l
CAUTION - Failure to heed the following may result in equipment damage.
Service Level Programming must only be attempted by authorized service centers.
Unauthorized adjustments in the Service Menu (beyond the LOC menu) may void chiller's warranty.
If the issue reoccurs, please contact the installing dealer. Or contact AquaCal ®
See "Contacting AquaCal AutoPilot, Inc." on page 1.
for a service partner in your area.
Table 1 - Factory Defaults
CODE DESCRIPTION
DEFAULT
VALUE
OFF
Chiller is deactivated.
HEA
COO
ACH
This is not an active feature on this equipment.
Set to cool water to point set on thermostat.
This is not an
OFF
RANGE
Page - 3
CODE DESCRIPTION
DEFAULT
VALUE
CF1
ELC active feature on this equipment.
Celsius /
Fahrenheit
Selection
1
Enter Lock Code 0
0 = Celsius
1 = Fahrenheit
RANGE
ULC User Lock Code
3.8 Setting Operating Mode
0
0 - 99
0 = "User Lock Disabled"
1 = "User Lock Enabled"
PLEASE NOTE
Do not attempt to operate chiller in heat modes HEA or ACH. This is not an active feature on this equipment.
Cool
Mode
Deactivate
Chiller
Heating / Cooling modes only available on select equipment. Confirm chiller features before setting a mode.
3.9 Setting Thermostats
Select "POOL" or
"SPA"
Press "UP" or
"DOWN" to the desired temperature.
l
The cooling indicator will illuminate when cooling the water.
Page - 4
3.10 Selecting Celsius or Fahrenheit
Hold "UP" and
"DOWN" until
CF1 displays.
"0" - Celsius
"1" - Fahrenheit
3.11 User Lock Option (Enable)
The user-lock feature allows the chiller control panel to be "locked"; preventing unauthorized temperature adjustments.
l l
Do not confuse a user-lock with the display lock.
If LOC is briefly displayed, followed by a "0", the chiller is already locked.
Hold "UP" and
"DOWN" until
CF1 displays.
Press "POOL /
SPA" button until
ELC is displayed.
Press "UP or
"DOWN" button to change or add a numerical password
Press "POOL /
SPA" button to lock in the password.
Press "POOL /
SPA" button until
ULC is displayed.
Press "Up" button till "1" is displayed to enable.
3.12 User Lock Option (Entering Pass Code)
If LOC is briefly displayed when attempting to change a chiller's settings followed by a "0", the chiller is in a user-lock mode. A numerical passcode is required to proceed.
Page - 5
Press "UP" or
"DOWN" arrow to enter user lock code.
Press "POOL /
SPA" button again to unlock.
NOTE l l
After three seconds of inactivity, the chiller's slide lock will activate.
If the user-lock code has been misplaced, the chiller must be reset to default factory settings.
See "Reset to Factory Defaults Settings" on page 1.
3.13 User Lock Option (Disable)
Use "UP" button to enter existing password.
Press "Pool / Spa" button to unlock.
Hold "UP" and
"DOWN" buttons until CF1 is displayed.
Press "POOL /
SPA" button until
ULC is displayed
Press "DOWN" button until "0" is displayed.
SECTION 4 - MAINTENANCE
4.1 Monitoring Conditions
4.1.a Water Chemistry
Check water chemistry regularly and maintain within recommended levels. Standards for commercial applications vary in different areas. Follow all local applicable codes.
Page - 6
l l
CAUTION - Failure to heed the following may result in equipment damage.
Do not allow water to flow through chiller when refinishing or acid washing a pool. Either use an installed bypass to route water away from chiller or deactivate filter pump.
To avoid damage to equipment, monitor and maintain chemistry within recommended levels.
CHEMISTRY LEVEL CHART
(RESIDENTIAL)
CHEMICAL POOLS SPAS
Chlorine 1.0 – 3.0 ppm 3.0 – 5.0 ppm
Bromine
Cyanuric
Acid pH
Total
Alkalinity
Calcium
Hardness
Total
Dissolved
Solids
•
2.0 – 6.0 ppm 2.0 – 6.0 ppm
30 - 50 ppm
7.4 – 7.6 ppm
80 – 120 ppm
200 – 400 ppm
0 – 1,500 ppm
30 - 50 ppm
7.4 – 7.6 ppm
80 – 120 ppm
150 – 250 ppm
1,500 ppm above start-up total dissolved solids in spas
•
Salt from a chlorine generator is not included in Total Dissolved Solids.
4.1.b Water Flow Rates
Maintain water flow rates as indicated. Please note, these specifications relate to the chiller only. Codespecified whole system turnover rates must be satisfied.
l
CAUTION - Failure to heed the following may result in equipment damage.
Water flow exceeding maximum flow rate may damage heat exchanger; such damage will not be covered under the equipment warranty
MODEL
FLOW RATES
HEAT EXCHANGER TYPE
MINIMUM MAXIMUM
TC500 Titanium Tube-in-Tube 20 GPM 45 GPM
TC1000 Titanium ThermoLink ® 30 GPM 70 GPM
If water flow through the chiller is reduced, performance will suffer and internal safety devices may deactivate the chiller with error codes LP or LP5.
l l l
Operate water filtration devices per manufacturer's specifications. Dirty filters can cause reduced water flow to the chiller. An increase of 7-10 psi higher than the clean filter pressure typically reduces flow rates. This requires the filter to be cleaned or back-washed
Keep baskets free of debris. Similar to a dirty filter, large volumes of debris in the pump and skimmer baskets can reduce water flow.
Check for improper valve settings. A partially closed valve after the filter, or a full-open bypass around the chiller, will cause insufficient water flow through the chiller.
Page - 7
l
The maximum static (or operating pressure) is 50 pounds-per-square-inch (PSI) unless a special "high-pressure" unit has been ordered. These specifications relate to the chiller only. Code-specified whole system turnover rates must be satisfied.
4.1.c Irrigation and Storm Run-Off l l
Corrosive irrigation water may damage chiller components. Have irrigation water directed away from the chiller.
The chiller will withstand normal rainfall. Do not allow a roof slope to direct rainwater onto the chiller. Have a gutter installed on the roof edge to direct this water away from the chiller. Or install the chiller in another location.
4.1.d Clearances l l
Proper air circulation is required for the chiller to operate efficiently. Avoid placing objects near or on top of the chiller. This includes shrubbery and lawn furniture. These objects will also hinder maintenance access.
Avoid storing chemical containers near the heat pump. The chemicals can cause equipment damage.
Overhead Clearance
(not including SideWinder ™ )
Page - 8
TropiCool ™ (Top View)
4.2 Cleaning Equipment
Cleaning and polishing your chiller regularly can protect its appearance longevity. More frequent servicing may be required for chillers located in sandy or coastal areas where sand and salt spray can become detrimental factors to equipment.
l
WARNING - Failure to heed the following may result in injury or death.
Possible electric shock hazard - Deactivate power to all electrical devices on the pad when washing chiller. Do not restore electrical power until equipment is completely dry.
l l l
CAUTION - Failure to heed the following may result in equipment damage.
Do not use a pressure cleaner to wash chiller. Damage to chiller components may result. If using a hose-end spray nozzle adjust spray pattern to low strength only.
Do not spray water directly into the interior of the chiller; damage to components may result.
Do not use chemicals on the control panel.
Cleaning
1. Wash outside cabinet using a low-pressure water hose. A high-pressure water stream will cause damage to the aluminum fins of the chiller This damage is not covered under product warranty.
2. While the chiller is still wet, use an approved cleaning agent to clean the exterior of the chiller. Do not use chemicals on the control panel.
3. Use a detergent-dampened cloth to wipe the chiller's exterior cabinet.
4. Flush all exterior with fresh water using a low-pressure water hose.
5. Dry the exterior cabinet using a soft cloth being careful not to damage condenser fins.
APPROVED CLEANING AGENTS
•
Fantastic
®
Formula 409
®
Cascade
®
All Power Plain Detergent (3% Solution)
Table 2 - Cleaning Agents
Polishing
1. Polish the chiller’s cabinet panels using an approved polishing agent and following the manufacturer’s instructions. Do not use chemicals on the control panel.
2. Rinse the chiller panels with fresh water, wipe, and buff panels using a dry soft cloth.
3. Allow chiller interior and surrounding equipment to "air-dry" for several hours prior to restoring electrical power.
APPROVED POLISHING AGENTS
•
Simoniz
®
Wax
AeroWax
®
Glo-Coat
®
Armor All
®
Protectant
Table 3 - Polishing Agents
•
The trademarks used in approved cleaning and polishing agents are property of their owners and are not related to AquaCal ® .
Page - 9
4.3 Planned Maintenance
An annual inspection and maintenance program is strongly recommended starting no longer than one year after installation of the chiller. See recommended annual inspection checklist.
AquaCal ® can perform this service in limited areas. Contact Customer Support for more information.
l
WARNING - Failure to heed the following may result in injury or death.
Annual inspection and service must be performed by a qualified chiller specialist in order to prevent physical injury or damage to equipment.
RECOMMENDED INSPECTION CHECKLIST: l l
Check Air Temperature Change through Evaporator
Check and Clean Condensate Drains l l l l l l l l l l l l l l
Check Capacitor Value
Check Compressor Amperage Draw
Check Electrical Connections
Check Flow / Pressure Switch
Check Operating Controls and Temperature Sensors
Check Water Chemistry
Check Proper Voltage to Unit
Check Refrigerant Levels
Check Relay Contacts
Check Water Flow
Check filter pump Amperage Draw
Check Water Temperature Change through Heat Exchanger
Clean Condenser's Coil
Clean Chiller's Cabinet
4.4 Winterizing l
WARNING - Failure to heed the following may result in injury or death.
Deactivate all electrical power to chiller before performing hard freeze procedures.
l l
CAUTION - Failure to heed the following may result in equipment damage.
Failure to winterize chiller may result in serious equipment damage. Freeze damage is not covered under the chiller warranty.
While the plumbing connections are in the winterized condition (not fully tightened), it is imperative the pool and spa water not be circulated through the chiller. Loss of water through loose plumbing connections may result in damage to circulating pump, pool and spa structures, and other equipment.
Light Freeze Conditions
There are two freeze conditions requiring chiller attention. A light freeze is when the ambient air temperature falls below 32 degrees Fahrenheit for less than 8 hours. Typically during light freeze conditions circulating (moving) water will not freeze. Override time clocks and allow filtration system to run continuously during light freeze conditions.
Hard Freeze Conditions
A hard freeze is when the ambient air temperature falls below 32 degrees Fahrenheit for more than 8 hours.
In areas where this condition is prevalent and sustained, the chiller MUST be winterized for hard freeze conditions. Follow the correct procedure depending on the type of heat exchanger found in the chiller.
Identify Exchanger:
1. Deactivate all electrical power to chiller.
2. Deactivate filter pump.
3. Remove front access panel.
4. Identify chiller exchanger from illustrations in this section. Then follow procedure for that chiller's exchanger.
Page - 10
Titanium ThermoLink ® Exchanger (with no Drain)
1. Reinstall front access panel.
2. Disconnect the plumbing to the chiller at connection unions (removal is counter-clockwise).
3. Allow water to drain completely from the chiller. Expect to see a lot of water drain out at first, and then a small amount to continue to drain out over a long period.
4. After chiller is fully drained, reinstall front access panel.
5. Partially reconnect plumbing connection unions.
6. Winterizing is complete.
7. When ready to use chiller again, hand-tighten connection unions. Reconnect electrical power, and set the operating mode on the chiller. Activate filter pump.
No Drain
Cupronickel Tube in Tube Exchanger
1. Reinstall front access panel.
2. Disconnect the plumbing to the chiller at connection unions (removal is counter-clockwise).
3. Place a garden hose into the inlet side of the chiller; wrap a clean rag around the hose to
Cupronickel
(Orientation form a temporary seal.
4. Turn on the garden hose water supply.
5. Allow water to run through the heat exchanger for 2-3 minutes; fresh water should be seen exiting the pool’s out-port.
6. Place a garden hose into the outlet side inlet of the chiller; wrap a clean rag around the hose depends on model) to form a temporary seal.
7. Turn on the garden hose water supply.
8. Allow water to run through the heat exchanger for 2-3 minutes; fresh water should be seen exiting the pool’s in-port.
9. Place an air hose into the pool inlet of the chiller; wrap a clean rag around the hose to form a temporary seal.
10. Push all water from the water circuit using compressed air at approximately 50 psig. The residual water should be forced out of the chiller pool outlet.
11. Allow compressed air to blow into the chiller inlet for at least 15-20 seconds after the water stops coming out.
12. Repeat process on the outlet side.
13. Partially reconnect plumbing connection unions.
14. Winterizing is complete.
15. When ready to use chiller again, hand-tighten connection unions. Reconnect electrical power, and set the operating mode on the chiller. Activate filter pump.
Page - 11
Titanium Tube-in-Tube Exchanger
1. Disconnect the plumbing to the chiller at connection unions (removal is counter-clockwise).
2. Allow water to drain completely from the chiller. Expect to see a lot of water drain out at first, and then a small amount to continue to drain out over a long period.
3. Place an air hose into the pool inlet of the chiller; wrap a clean rag around the hose to form a temporary seal.
4. Push all water from the water circuit using compressed air no stronger than 50 psig. The residual water should be forced out of the pool outlet. Allow compressed air to blow into
Titanium
Tube-in-
Tube the chiller inlet for at least 15-20 seconds after the water stops coming out.
5. Repeat process on the outlet side of the chiller.
6. Partially reconnect plumbing connection unions.
7. Winterizing is complete.
8. When ready to use chiller again, hand-tighten connection unions. Reconnect electrical power, and set the operating mode on the chiller. Activate filter pump.
SECTION 5 - TROUBLESHOOTING
5.1 Fault Codes
A fault code indicates a specific issue or condition that will require action before the equipment can resume operating.
Please perform the following troubleshooting.
If the issue reoccurs, please contact the installing dealer. Or contact AquaCal ® for a service
partner in your area. See "Contacting AquaCal AutoPilot, Inc." on page 1.
l l
WARNING - Failure to heed the following may result in injury or death.
Repairs must not be attempted by untrained or unqualified individuals.
The chiller contains refrigerant under high pressure. Repairs to the refrigerant circuit must not be attempted by untrained or unqualified individuals. Service must be performed only by qualified HVAC technicians. Recover refrigerant before opening the system.
l
CAUTION - Failure to heed the following may result in equipment damage.
Service by unauthorized personnel will void the chiller warranty.
FLO Indicator
ISSUE
Low or no water detected.
RESOLUTION
1. Confirm the filter pump is on.
2. If a multiple-speed filter pump is being used, run at a higher speed to determine if the error persists. Do not exceed maximum flow rate for your model.
3. Confirm water is not being diverted away from the chiller.
l l
See "Water Flow Rates" on page 7.
See "Adjusting Water Flow Using ΔT (Delta-T)" for more information.
Page - 12
CEr Indicator
ISSUE
This can indicate a loose or damaged communication cable.
RESOLUTION
A qualified technician should check the cable from control board to display assembly for a loose connection or visible damage.
CSE Indicator
ISSUE
This is a control system error.
RESOLUTION
1. Deactivate then reactivate power to reset controls.
2. If the issue reoccurs, please contact the installing dealer. Or contact AquaCal ® for a service partner in your area.
See "Contacting AquaCal AutoPilot, Inc." on page 1.
DpC or DpO Indicator
ISSUE
Shorted or open defrost sensor.
RESOLUTION
A qualified technician should replace the defrost sensor.
pC or pO Indicator
ISSUE
Shorted or open water sensor.
RESOLUTION
A qualified technician should replace the defrost sensor.
HP Indicator
ISSUE
The refrigerant system’s high-pressure switch is showing as open.
RESOLUTION
1. Determine if an insufficient amount of water is being supplied to the equipment.
a. Confirm the filter pump is on.
b. If a multiple-speed filter pump is being used, run filter pump at a higher speed. Do not exceed maximum flow rate for your model.
c. Confirm water is not being diverted away from the chiller.
l
See "Water Flow Rates" on page 7.
l
See "Adjusting Water Flow Using ΔT (Delta-T)" for more information.
2. If the issue reoccurs, please contact the installing dealer. Or contact AquaCal ® for a service partner in your area.
See "Contacting AquaCal AutoPilot, Inc." on page 1.
Page - 13
HP5 Indicator
ISSUE
The chiller has locked due to five HP (high-pressure) faults during one call for heating or cooling.
RESOLUTION
1. Deactivate then reactivate power to the chiller to clear error.
2. Troubleshoot the high-pressure issue causing the error. See "HP Indicator" on page 13.
3. If the issue reoccurs, please contact the installing dealer. Or contact AquaCal ® for a service partner in your area.
See "Contacting AquaCal AutoPilot, Inc." on page 1.
LP Indicator
ISSUE
The refrigerant system’s low-pressure switch is showing as open.
RESOLUTION
1. Check for obstructed air flow around the heater. See "Clearances" on page 8.
2. Check for dirty or blocked evaporator coil. See "Cleaning Equipment" on page 9.
3. Check for signs of ice buildup on the coil.
4. For further assistance, please contact the installing dealer. Or contact AquaCal ® for a service partner in your area.
See "Contacting AquaCal AutoPilot, Inc." on page 1.
LP5 Indicator
ISSUE
The chiller has locked due to five LP (low-pressure) faults during one call for heating or cooling.
RESOLUTION
1. Deactivate then reactivate power to the chiller to clear error.
2. Troubleshoot the low-pressure issue causing the error. See "LP Indicator" on page 14.
OtA Indicator
ISSUE
Incoming water temperature exceeded 110° F and the unit is locked with an OtA over temperature alarm.
The chiller will not operate until incoming water temperature drops to 100° F or lower.
RESOLUTION
1. Rule out an incorrect reading from the water temperature sensor. Verify existing water temperature with an accurate thermometer. If chiller’s sensor is inaccurate, the water temperature sensor may require replacement.
5.2 Issues and Resolutions l l
WARNING - Failure to heed the following may result in injury or death.
Repairs must not be attempted by untrained or unqualified individuals.
The chiller contains refrigerant under pressure. Repairs to the refrigerant circuit must not be attempted by untrained or unqualified individuals. Service must be performed only by qualified HVAC technicians. Recover refrigerant before opening the system.
l
CAUTION - Failure to heed the following may result in equipment damage.
Service by unauthorized personnel will void the factory warranty.
Please perform the following troubleshooting.
For further assistance, please contact the installing dealer. Or contact AquaCal ® for a
service partner in your area. See "Contacting AquaCal AutoPilot, Inc." on page 1.
Page - 14
Control Panel Not Responding
1. If the chiller is controlled be an external controller, confirm the external controller settings. See "Operating
Chiller (With an External Controller)" on page 1.
2. If the issue is still occurring, contact the manufacturer of the external control device.
3. For further assistance, please contact the installing dealer. Or contact AquaCal ® for a service partner in your area.
See "Contacting AquaCal AutoPilot, Inc." on page 1.
Chillers Not Running
1. Confirm equipment is receiving power. Is the chiller display illuminated?
l
If not, confirm the main breaker (located at the power supply panel) and the disconnect switch (located l near the chiller) are both turned on.
If the display still does not illuminate, it is recommended that the chiller installer or electrician confirms chiller is receiving power.
2. Confirm correct mode is selected. See "Setting Operating Mode" on page 4.
3. Confirm thermostat is set correctly. See "Setting Thermostats" on page 4.
l
If cooling the water, the thermostat should be set below the current water temperature.
5. For further assistance, please contact the installing dealer. Or contact AquaCal ® for a service partner in your area.
See "Contacting AquaCal AutoPilot, Inc." on page 1.
Chillers Tripping Breaker
1. Have an electrician confirm breakers are in good condition and properly sized for the chiller.
2. Multiple chillers installed at the same site may benefit from special automatic sequencing controllers to avoid excessive power drops at start-up.
See "Automatic Sequencing Controller" on page 18.
3. If a fault occurs immediately when the compressor starts, a qualified technician should evaluate the system.
Chiller Won’t Shut Off
Chiller Is Running, Not Cooling (Reversing Models)
1. Confirm the chiller mode is set to COO operating mode.
2. Confirm the thermostat is set below the current water temperature.
3. Confirm chiller is transferring heat out of the water.
l
Measure the temperature of air discharge coming out of chiller fan. If discharge air is between 8° to 10° warmer than outside ambient air (not coming out of chiller), then the chiller is moving heat out of the water.
5. Confirm valves are correctly positioned to cool the correct body of water (either the pool or the spa). If cooling a spa that overflows into a pool, confirm the spa is isolated when being cooled (not flowing into the pool).
6. Confirm that filter pump has a sufficient run-time. The chiller will not run (or cool the water) without water flow.
See "Initial Cooling Recommendations" on page 18.
Page - 15
Water Coming From Chiller
The water may be normal condensation produced as a by-product of the chiller's refrigeration process. The chiller can produce 8 to 10 gallons of condensation per day depending on the humidity of the ambient air.
Determine if the water is condensation or a possible leak.
1. If using chlorine or bromine as a pool / spa sanitizer, use a test strip in the water at chiller to determine if sanitizer is present. If sanitizer is present, a leak may exist.
2. Deactivate chiller, leaving the filter pump on. After several hours, determine if water is still coming from the chiller.
3. If the issue reoccurs, please contact the installing dealer. Or contact AquaCal ® for a service partner in your area.
See "Contacting AquaCal AutoPilot, Inc." on page 1.
Page - 16
SECTION 6 - APPENDIX
6.1 Identifying Model Specifications
1. Find Data Plate - The data plate is usually posted on the side of the equipment or on the control panel access plate.
2. Find the model number on the data plate. The first letters and numbers indicate the model type.
3. The complete model number identifies the equipment's specifications.
Data Plate Example
Model Number Example
Page - 17
6.2 Initial Cooling Recommendations
The following recommendations will reduce the amount of time required to cool a pool or cold plunge
Model Specifications" on page 17.
1. Confirm chiller mode has been set to COO.
2. Set thermostat to desired water temperature.
3. Temporarily override the filter pump's time-clock for continuous operation.
l l
This will allow the Chiller the time required to cool the water at start-up.
After the water has reached the desired temperature, the time-clock can be reset to normal operating time-frames.
6.3 Available Accessories
Automatic Sequencing Controller l
An Automatic Sequencing Controller (ASC) provides easy control of all units from one lead unit and prevents the l l simultaneous start-up of multiple chillers.
Site voltage drop is minimized and utilities are not subjected to large in-rush demands of electrical current.
Part number is based on number of chiller's to be controlled. Call AquaCal ® Customer Support for assistance with correct configuration.
5 lb Bypass Valve Kit (Kit STK0135) l
When high flow rates are outside recommended tolerances, please use this kit or an alternative bypass valve l system.
This kit can be used to control excessive water flow through the chiller. It provides automatic flow adjustments for most applications.
External Flow Relay (Grid Flow) Switch Kit (0040s) l l
Used when the pool / spa elevation is higher than the chiller.
Used when a variable two-speed filter pump set on low-speed mode does not provide enough water pressure to l activate a chiller’s water pressure switch.
Also used for automatic pool / spa thermostat switching.
Remote Control Kit (STK0070) l
A remote (wired) control kit allows for full control of the chiller from up to 100 feet from the equipment.
Plumbing Unions:
SIZE PART NUMBER
2 INCH 2627
Page - 18