Agilent PXI and AXIe Modular Products Catalog

Agilent PXI and AXIe Modular Products Catalog
Agilent
PXI and AXIe
Modular Products
Catalog
September 2013
Challenge the Boundaries of Test
Agilent Modular Products
A Letter from our President
Dear Valued Customer,
I am pleased to present this new edition of the Agilent PXI and AXIe
Modular Instruments catalog. Agilent’s modular instruments portfolio
gives you expert measurement science in the PXI and AXIe form factors.
As you look through it I hope you’ll find the measurement modules and
companion software required for your test needs. They are optimized for
testing applications that require high-performance, high-speed and highthroughput, and enable new capabilities that were not previously available
across analog, digital, RF, microwave and lightwave technologies.
Agilent Technologies’ Electronic Measurement Group is committed
to be your measurement partner on applications that require modular
instrumentation.
Give us your feedback; we count on it to ensure that we continue to meet
your requirements. I hope you will look to Agilent’s innovative products
and solutions to help you achieve your business results.
Sincerely,
Guy Séné
Senior Vice President, Agilent Technologies, Inc.
President, Electronic Measurement Group
2
t able o f c ont ent s
SECT ION
Product Category Index
1
The Modular Advantage
2
Modular Software Environment
3
Chassis and Controllers
4
Bit Error Rate Testers
5
Data Acquisition and Switching
6
Digital Input Output
7
Digital Multimeters
8
Digitizers
9
Digital to Analog Converters
10
Function and Arbitrary Waveform Generators
11
Logic Analysis and Protocol Test
12
Optical Extenders
13
Signal Analyzers nnd Signal Conditioning
14
Signal Generators (Sources)
15
AXIe Modular Products
16
Programming Environment
17
Recommended/Tested Computer List
18
Become a Partner
19
Customer Support and Warranty Information, Specification Definitions
20
Indexes
21
3
Pro du c t c a t eg ory i nd e x
m o del
descriptio n
page
PXI chassis a n d co n trollers
M9018A
PXIe Chassis: 18-slot, 3U, 8 GB/s
19
M9021A
PCIe Cable Interface: x8
20
M9036A
PXIe Controller
21
M9045B
PCIe Laptop Adapter: x1
22
M9048A
PCIe Desktop PC Adapter: Gen 2, Clock Isolation
23
®
PXI BIT E RROR RA T E T ES T ERS ( B ERT S )
N2099A
PXI RF Synthesizer
27
N2100B
PXI Digital Communication Analyzer
28
N2101B
PXI Bit Error Rate Tester
29
N2102B
PXI Pattern Generator
30
PXI DA TA A C QU I S I T I O N A N D S W I T CH I N G
1
M9101A
PXI High Density Multiplexer: 64-ch, 2-wire, 100 Vdc/1A, Reed Relays
37
M9102A
PXI High Density Multiplexer: 128-ch, 1-wire, 100 Vdc/1A, Reed Relays
37
M9103A
PXI High Density Multiplexer: 99-ch, 2-wire, 100 Vdc/1A, EM Relays
37
M9120A
PXI Matrix Switch: 4x34, 2-wire, 100 Vdc/2A, EM Relays
38
M9121A
PXI Matrix Switch: 4x64, 2-wire, 100 Vdc/.5A, Reed Relays
38
M9122A
PXI Matrix Switch: 8x32, 1-wire, 100 Vdc/2A, EM Relays
38
M9128A
PXI RF Matrix Switch: 300 MHz, 8x12, 50 Ω
39
M9130A
PXI SPDT Switch: 26-ch, 100 Vdc/2A, EM Relays
40
M9131A
PXI SPDT Switch: 64-ch, 100 Vdc/2A, Reed Relays
40
M9132A
PXI SPST Switch: 50-ch, 100 Vdc/1A, Reed Relays
40
M9133A
PXI SPST Switch: 100-ch, 10 Vdc/1A, Reed Relays
40
M9135A
PXI SPST Power Relay, 20-ch, 10 A @ 250 Vac, 300 W
40
M9146A
PXI RF Multiplexer: 3 GHz, Dual 1x4, 50 Ω, Terminated
39
M9147A
PXI RF Multiplexer: 3 GHz, Dual 1x4, 50 Ω, Terminated Common
39
M9148A
PXI RF Multiplexer: 3 GHz, 1x8, 50 Ω
39
M9149A
PXI RF High Density RF Multiplexer: 3 GHz, Dual 1x16, 50 Ω
39
M9150A
PXI RF Multiplexer: 3 GHz, Dual 1x4, 75 Ω
39
M9151A
PXI RF Multiplexer: 3 GHz, Quad 1x4, 75 Ω
39
M9152A
PXI RF Multiplexer: 3 GHz, 1x8, 75 Ω
39
M9153A
PXI RF Multiplexer: 3 GHz, 1x16, 75 Ω
39
M9155C
PXI Hybrid Dual SPDT Coaxial Switch, DC to 26.5 GHz
41
M9156C
PXI Hybrid Dual Transfer Switch, DC to 26.5 GHz
41
M9157C
PXI Hybrid Single SP6T Switch, DC to 26.5 GHz
41
M9155CH40
NEW
PXI Hybrid Dual SPDT Coaxial Switch, DC to 40 GHz
42
M9156CH40
NEW
PXI Hybrid Dual Transfer Switch, DC to 40 GHz
42
M9157CH40
NEW
PXI Hybrid Single SP6T Switch, DC to 40 GHz
42
M9170A
PXI Attenuator/Switch Driver module
43
M9216A
PXI 32-Channel High Voltage Data Acquisition Module
44
PXI Digital input output
M9187A
PXI Digital IO: 32-ch, 0.3 to 50 V
46
PXI Digital M U LT I MET ERS
4
M9181A
PXI Basic Features DMM
49
M9182A
PXI Digital Multimeter: 6½ digit
50
M9183A
PXI Digital Multimeter: 6½ digit, Enhanced Performance
50
Pro du c t c a t eg ory IN d e x
m o del
descriptio n
page
PXI DIGITIZE RS
M9202A
PXIe IF Digitizer: 12-bit, 1 GHz
53
M9210A
PXI-H Digitizing Scope: 10-bit, 2-4 GS/s
54
M9211A
PXI-H UWB IF Digitizer: 10-bit, 4 GS/s, 3 GHz
55
PXI Digital to a n alog co n verters
M9185A
PXI 8/16-Channel Isolated D/A Converter
59
M9186A
PXI Isolated Single Channel Voltage/Current Source, 100 V
60
PXI F un ctio n a n d A RB I T RA RY W A V EFO RM G E N E R A T O R S
M9330A
PXI-H Arbitrary Waveform Generator: 15-bit, 1.25 GS/s
63
M9331A
PXI-H Arbitrary Waveform Generator: 10-bit, 1.25 GS/s
64
pxi LOGIC ANALYSIS AND PROTOCOL TEST
M9252A
NEW
DigRF Host Adapter
66
pxie optical exte n ders
M9403A
M9403A PXIe Optical Transmitter: 300 kHz to 26.5 GHz or 50 GHz
68
M9404A
M9404A PXIe Optical Receiver: 300 kHz to 26.5 GHz or 50 GHz
68
M9405A
M9405A PXIe Optical Amplifier: 300 kHz to 26.5 GHz or 50 GH
68
M9406A
M9406A PXIe Optical to USB 2.0
68
M9407A
M9407A PXIe Optical to 4 Port USB 2.0 Hub
68
M9408A
M9408A PXIe Optical Remote RF Reflectometer
68
1
PXI SIGNA L A N A Ly Z ERS A N D S I G N A L CO N DI T I ON E R S
X-Series Apps
NEW
X-Series Measurement Applications for Modular Instruments software
72
89601B
89600 VSA software
73
W1461BP
SystemVue software
74
M9391A
PXIe Vector Signal Analyzer: 1 MHz to 6 GHz
75
Dual Channel System
PXI Dual Channel Vector Signal Analyzer
76
M9392A
PXI Vector Signal Analyzer: 50 MHz to 26.5 GHz
77
MIMO System
PXI Wideband MIMO Vector Signal Analyzer
78
M9362A-D01
PXIe Quad Downconverter
79
M9168C
PXI Programmable Step Attenuator
80
M9202A
PXIe IF Digitizer: 12 bit, 1 GHz
81
M9302A
PXI Local Oscillator: 3 GHz to 10 GHz
82
M9351A
PXI Downconverter: 50 MHz to 2.9 GHz
83
M9352A
PXI Hybrid Amplifier Attenuator
84
M9360A
PXI Attenuator/Preselector: 100 kHz to 26.5 GHz
85
M9361A
PXI Downconverter: 2.75 GHz to 26.5 GHz
86
NEW
PXIe SIGNAL GENERATORS (SOURCES)
M9099
Waveform Creator software
89
W1461BP
SystemVue software
90
Signal Studio
Signal Studio software
91
M9381A
PXIe Vector Signal Generator
92
M9380A
PXIe CW Source
93
M9300A
PXIe Frequency Reference
94
M9502A
AXIe 2-slot Chassis
97
M9505A
AXIe 5-slot Chassis
97
M9536A
AXIe Embedded PC Controller
98
M9703A
AXIe Digitizer 12-bit, 8 Channels
99
NEW
AXIe MODULES
5
Pro du c t c a t eg ory IN d e x
m o del
descriptio n
page
AXIe MODULES (cont'd)
M8190A
AXIe Arbitrary Waveform Generator
U4154A
AXIe Logic Analyzer 4 Gb/s
101
U4301A
AXIe Protocol Analyzer PCI Express® 3.0
102
AXIe Protocol Analyzer and Exerciser for MIPI™ D-PHY Interfaces
103
AXIe Protocol Analyzer for MIPI™ M-PHY Interfaces
104
U4998A
AXIe Protocol Analyzer HDMI 1.4b
105
M9045B
PCIe Laptop Adapter: x1
106
M9048A
PCIe Desktop PC Adapter: Gen 2, Clock Isolation
107
U4421A
U4431A
NEW
100
PROGRA MMING ENV I RO N MEN T
1
6
E2094
IO Libraries Suite 16 software
110
E2300
Command Expert software
111
N6171A
Matlab software
112
TH E MODULAR ADVANTAGE
High performance and easy test system design...
For your data acquisition or automated test applications, your range of choices is
getting bigger and better.
2
Agilent modular instrumentation extends Agilent’s measurement expertise into
modular form factors, such as PXI and AXIe. In these form factors, Agilent helps
you benefit from a large portfolio of chassis and measurement modules integrated
with world-class software applications to get the most trusted measurements in
the DC, analog, digital, RF, microwave and lightwave domains.
Our offering includes a new PXI RF vector signal analyzer/generator enhanced by
software applications including the X-Series measurement applications for modular instruments. Products also include a
modular microwave vector signal analyzer, digitizers, waveform generators, digital multimeters, voltage/current sources
(V/I), and a broad range of multiplexers, matrices and general purpose switching products that cover from DC to 40 GHz.
Architecture
Software
High performance, flexible architecture
Open development software platform
To ensure that you get the best performance from your
test platform, the entire path from the controller to the
instrument has been designed for speed.
Because a single software platform is rarely the right
answer for every test scenario, Agilent provides modules
with a comprehensive portfolio of instrument drivers, documentation, examples, and software tools to help you quickly
develop test systems with your software platform of choice.
• PCI Express® IO path from the controller to the
instrument enables high-speed connectivity from faster,
less-expensive remote controllers.
• High-speed memory-mapped registers reduce firmware
overhead and communication latency.
• Optimized software drivers.
Agilent also develops application software for design
automation, verification, measurement and analysis capabilities. Applications such as SystemVue, X-Series measurement applications for modular instruments, 89600 VSA
software, Waveform Creator, Signal Studio and MATLAB
support a number of Agilent modular products.
www.agilent.com/find/modular
7
TH E MODULAR ADVANTAGE
Why choose Agilent modular products?
Agilent has been a pioneer in developing and supporting advanced modular platforms. From the early days of leveraging
VMEbus and integrating timing and synchronization to create VXI to the popular 34970 and 34980 switching and data
acquisition platforms, Agilent is taking its modular expertise to furthering advancements in PXI and AXIe.
Measurement expertise
Automation optimized software and hardware
Measurement consistency and efficiency from R&D to manufacturing
Open SW platform supporting MATLAB, VEE, LabVIEW, VisualStudio
2
Worldwide support and calibration and 3 year standard warranty
Measurement expertise
Agilent's long tradition of investing in advanced research
furthers the foundation of measurement science through
Agilent’s Technology Leadership Organization and Agilent
Research Labs. Our products integrate decades of unique
signal and measurement algorithms to bring the most
advanced hardware and software solutions to market. You
benefit from this expertise in the early stages of product
design to manufacturing.
Software and hardware optimized for test
automation applications
Agilent developed PXI measurement hardware, software
applications and drivers, optimized for test automation, to
give users the lowest latency solutions. This translates
directly to lower measurement times and higher test
throughput.
Measurement consistency and efficiency from R&D
to manufacturing
Reduce design cycle times through use of common
software applications and measurement algorithms
from design to manufacturing. Implement a platform for
modeling, implementing and validating next generation
communications systems. Use the same measurement
applications in the lab and in your manufacturing environment to generate consistent test results.
8
Open software platform supporting MATLAB, VEE,
LabVIEW, VisualStudio
With Agilent’s modular open software platform, you have
the largest choice of software applications and programming environments with complete support of MATLAB,
VEE, LabVIEW, and Microsoft VisualStudio software.
Furthermore, Agilent provides IVI-COM and IVI-C support
for integration into almost any software environment.
Comprehensive worldwide support and calibration
- 3 year standard warranty
From instrument maintenance and repair, to calibration and
software solutions or consulting and education, Agilent
offers services and a 3 year warranty to lower your total
cost of ownership.
Agilent performs calibrations at its owned service centers
and offers the highest number of RF parameter accreditations. There are over 50 locations in Agilent's global
network to service your needs around the globe.
TH E MODULAR ADVANTAGE
Is PXI the right choice for your application?
Summarized below are some of the unique benefits offered by an Agilent modular PXI platform.
Modular platform benefits
Higher measurement throughput
Technology innovations embedded in our PXI products
enable fast tests and measurements. By leveraging computer-based technology, PXI also takes advantage of the
latest advances in processors, reducing post-processing
time. The PXIe backplane bus utilizes the PC industry’s
PCI Express® Gen2 technology, greatly increasing throughput and reducing latency. This technology helps transfer
information between modules and controller at higher
speeds, and will reduce test time, especially for data and
transaction intensive test applications. In addition, Agilent
PXI systems include a built-in streamlined driver architecture with direct memory access, and the measurement
science used to take the measurement.
Greater flexibility and scalability
PXI is an open, multi-vendor standard that is governed by
the PXI Systems Alliance (www.pxisa.org). This ensures
that modules and infrastructure from different vendors can
be used together. In addition, by integrating the bus into
the backplane of the chassis, it is possible to continue
scaling systems using PXI timing and synchronization
methods.
Integrated systems
PXI easily integrates into hybrid systems where a test
platform is a combination of standalone benchtop, proprietary modular, GPIB, USB, VXI, LXI or even the new AXIe
modular form factor. Agilent’s IO library suite makes the
integration faster, by offering easy connection to both PXI
and traditional instruments and reducing system setup and
configuration time to mere minutes.
2
Smaller footprint
The biggest contributing factor aside from taking advantage of Moore’s Law of integration and miniaturization
is the removal of redundant functions in a integrated
system. By abstracting the measurement technology from
the processing and user interface functions, PXI removes
redundancy and can save up to 80% of the space of a
traditional system.
Lower power consumption
By virtue of taking advantage of advances in miniaturization and integration, PXI can limit slot power to 30W and
still meet many of the needs of higher-end measurements.
This means that a fully loaded 18-slot chassis still uses
less than 1000W.
9
TH E MODULAR ADVANTAGE
Is AXIe the right choice for your application?
What is AXIe?
AXIe is a next-generation open standard based on Advanced Telecom Computing Architecture
(AdvancedTCA®) with extensions for instrumentation and test. This standard is governed by the AXIe
Consortium, a group of leading organizations in the test and measurement industry and is designed to
provide users with popular PC interfaces such as TCP/IP and PCI Express® to modular configuration slots
which provide resources for advanced instrumentation (www.axiestandard.org).
AXIe’s key attributes
As a standard, AXIe shares many characteristics with
PXI but was designed to supplement the automated
test platform standard.
2
A quick look at a few details reveals the underlying
similarities and differences offered by AXIe. As the
table shows, AXIe and PXI offer similar latency and
transfer speeds because both use PCI Express as the
backplane fabric.
Discover the Agilent...
Feature
AXIe
PXIe
Chassis base
AdvancedTCA
cPCI, cPCIe
PCIe maximum data bandwidth (Gen2)
Single peripheral slot to backplane
All peripheral slots to system slot
2 GB/s
10 GB/s (5-slot chassis)
4 GB/s
8 GB/s
PCIe fabric
Yes
Yes
LAN backplane
Yes
No
Local bus
18 pairs required
62 pairs optional
1 line (13 PXI)
Triggers
Bi-directional star trigger
13-signal MLVDS bus
Star trigger (1x TTL, 3x diff per slot)
Eight-signal TTL bus
Frequency reference and sync
100 MHz; Yes
10 MHz, 100 MHz; Yes
Power per slot
200 W
30 W
Board space per slot
900 cm²
160 cm²
Modules available
Dozens and growing
>1,000
AXIe and PXI Difference
10
TH E MODULAR ADVANTAGE
Is AXIe the right choice for your application?
How is AXIe different than PXI?
AXIe Interoperability
While PXI has made a name for itself in automated validation and manufacturing test applications on the strengths
of its compact size, low power draw, and best in low-cost
commercial off-the-shelf ASICs and technologies, AXIe
balances PXI by providing the complement of these aforementioned features.
AXIe is built on the same PCI Express® backplane fabric
as PXI and the same LAN connectivity as LXI. This allows
the three platforms to co-exist in the same system quite
seamlessly.
Powerful
Truly advanced and cutting edge
measurement technologies previously
unavailable to modular instrumentation
In addition, the PXI and AXIe platforms will share the
same software architecture both taking advantage of IVI
and other elements of the driver software stack. AXIe
also supports embedded controllers running user familiar
operating systems such as Microsoft Windows. All of this
makes AXIe seamless to develop for and integrate into an
advanced measurement platform.
Seamless
By increasing the power available to each slot from 30 W to
200 W, loosening board space constraints from 160 cm² to
900 cm², and increasing the headroom of each slot, leading
test and measurement providers can now use AXIe as a
platform for truly advanced and cutting edge measurement
technologies previously unavailable to modular instrumentation. The additional power now supports extreme ASICs
with switching speeds in the tens of gigahertz and power
draws greater than 30 W. The additional board space will
allow the development of complex measurement architectures with their supporting circuits all on a single card.
Additionally, the extra slot headroom will allow mezzanine
circuits for increased densities per slot or additional shielding to support very sensitive circuits. In brief, AXIe finally
supports the development of cutting edge instrumentation
in a modular form factor.
PXI and AXIe share the same software
architecture and familiar operating systems
AXIe Products
The AXIe product portfolio includes mainframes, a controller and new modules that offer leading performance in
their categories.
Interconnected
Systems designers are now limited only by
their imagination
Another subtle difference between the two platforms is the
augmented local bus which allows communications and
synchronization between instrumentation slots. With over
600 GB/s of throughput, local bus now facilitates complex
multi-instrument configurations for channel expansion,
data storage and co-processing as well as internal
synchronization and triggering. System designers are now
limited only by their imagination.
Agilent M8190A Arbitrary Waveform Generator
11
2
mo du la r s oft w a re e n vi r o n m e n t
PXI & AXIe - Easy setup and configuration
Modular test systems require a variety of hardware
and software components. When configuring your
systems you need to ensure compatibility between the
mechanical, electrical and software aspects and achieve
successful operation. Agilent provides a wide variety
of tools to accelerate your system setup and give you
confidence in its operation.
S ta r tu p A s si st ance
An Agilent Technologies applications engineer can help
you get started quickly by installing the modules in a
chassis, configuring the controller, loading software and
making your first measurements.
3
Easy M odule Setup
Soft Front Panels
A c h i e v e I n st r um e nt C o nne ct i o n
Agilent modules come with a Soft Front Panel - a Graphical
User Interface (GUI), which guides you through module
setup, helps you configure the instrument parameters,
verifies connectivity to a module and explores its
functionality.
Agilent IO Library
The free Agilent IO Libraries Suite
offers fast and easy connection to
modular and traditional instruments. It
automatically finds interfaces, chassis
and instruments, explores your configuration and
updates IVI instrument drivers.
Agilent’s SFP enhances the out-of-box experience by
providing measurement capabilities right away. The SFP
utility is enriched with a code-generation functionality
that automatically generates the code you can directly
copy from the SFP setup into your system software. This
is useful during software development and debug, and
used to perform benchtop measurements with one or more
modular devices.
Already have multiple vendor I/O software installed?
Agilent’s open IO Libraries Suite provides system
interoperability by automatically detecting National
Instrument’s software and safely installing the Suite in
a side-by-side mode allowing the existing I/O software
and Agilent software to work together.
Please see more details at page 110 or
www.agilent.com/find/iosuite
Q u i c k l y D i sco v e r and Manag e
Mo d ul e s
Agilent Connection Expert
The Agilent Connection Expert, included
in the free Agilent IO Library suite,
allows you to search for, verify, and
update IVI instrument and soft front panel drivers. This
saves you time and ensures that the most up-to-date
drivers are being used within your application.
If your test system is a combination of modular and
traditional instruments, the Agilent Connection Expert
also identifies instruments connected though AXIe,
GPIB, Ethernet/LAN and more.
Please see more details at page 110 or
www.agilent.com/find/iosuite
12
Agilent Vector Signal Analyzer soft front panel
MODULAR SOFTW ARE EN V I RON M ENT
PXI & AXIe - Accelerate system development
S o f tw a r e . . . Yo u C ho o se !
To support your software choice, every Agilent module
includes the IVI-COM, IVI-C, LabVIEW and MATLAB
software drivers that work in the most popular T&M
development environments including, Visual Studio (VB.
NET, C#, C/C++), VEE, LabVIEW, LabWindows/CVI, and
MATLAB. The instrument drivers provide context sensitive
help such as Microsoft IntelliSense and LabVIEW hoverhelp complete documentation, and examples to decrease
startup time on complex tasks.
If you work with multi-module instruments, Agilent’s
integrated drivers help you easily control instrument functions.
S e a ml e s s Co nt r o l and P r o g r am m ing
Command Expert
Traditional T&M development enviroments
typically do not offer assistance in finding
the right instrument commands, setting
the correct parameters, passing data
and variables. Agilent’s free Command
Expert combines instrument commands,
documentation, syntax checking and command execution
all in one simple interface. It helps you run and debug
command sequences before integrating them into other
programming environments, such as MATLAB, Microsoft
Excel, Agilent VEE, and LabVIEW.
Please see more details at page 111 or
www.agilent.com/find/commandexpert
A g i l e n t’ s Me asur e m e nt Sci e nce
Agilent’s PXI modular products are an extension of Agilent
measurement science in the PXI form factor. You can
benefit from the same signal generation and analysis
software that is currently used with Agilent benchtop
instruments and get consistent measurements throughout
the entire design and test flow.
A g i l e n t' s Wo r l d - C l ass So ft war e
A p p l i c a ti o ns
SystemVue
When used with Agilent modular products, SystemVue
creates an expandable platform for modeling, implementing
and validating next generation communications systems.
A modular approach enables you to create a virtual system
to be verified from the first day of the project - beginning
with simulation models.
www.agilent.com/find/systemvue
Agilent's World-Class Softw are
Applic ations (c ont'd)
X-Series Measurement Applications
for Modular Instruments
NEW
Expand the capabilities of your
M9391A PXIe Vector Signal Analyzer
with Agilent's library of measurement
applications - the same applications used
by its X-Series signal analyzers. Agilent’s
X-Series Measurement Applications for
Modular Instruments transform PXIe VSAs into standards
based RF transmitter testers, enabling you to test more
products in less time while ensuring measurement
continuity from design to manufacturing.
www.agilent.com/find/pxi-X-Series_apps
3
Vector Signal Analysis Software
Agilent’s industry-leading 89600 VSA
software is a comprehensive set of
tools for demodulation and vector signal
analysis. These tools enable you to
explore virtually every facet of a signal and
optimize your advanced designs.
www.agilent.com/find/vsa
Waveform Creator Software
NEW
Easily create complex, customized
waveforms with this new "drag and
drop" graphical user interface and
plug-in to Vector Signal Generators or
Arbitrary Waveform Generators. Create
multi-format, multi-track waveforms with
wave segments displaced in frequency and time.
www.agilent.com/find/m9099
Signal Studio Software
Whether you’re working on a single radio
format or integrating multiple formats
into a single device, easy access to the
right test signals streamlines validation
and helps ensure interoperability.
Signal Studio is a flexible suite of signal-creation tools
that reduces the time you spend on signal simulation. Its
performance-optimized reference signals—validated by
Agilent—enhance the characterization and verification of
your devices.
www.agilent.com/find/signalstudio
13
ACHIEVE LOW ER COST OF O WNERS H I P
Calibration and repair can significantly influence the cost
of owning a system. Agilent modular products are designed
to maximize uptime through easy module exchange for
maintenance, repair and calibration that helps keep your
test systems operational.
Fast Repair Times
Core Exchange Program
Benefit from fast repair times, whether your repair strategy
is return to Agilent, on-site repair, or self-maintainer.
3
For selected modular products, Agilent’s replacement Core
Exchange program allows fast and easy module repairs.
A replacement core assembly is a fully functioning precalibrated module replacement that is updated with the
defective module serial number, allowing the replacement
module to retain the original serial number.
Standard Global Warranty - 3 years
NEW
We take pride in our product quality, as evidenced by our
3 year standard warranty. Our standard repair turnaround
time averages less than 14 days. You have the option to
extend the warranty to 5 years.
Express Warranty - 5 day turnaround
For selected modular products, reduce downtime with the
fastest repair service in the industry. The express warranty
upgrades the global warranty to provide:
• 5 day typical turnaround repair service in the US, Japan,
China and many EU countries or up to a 10 day
improvement in turnaround time in the rest of the world.
• Priority return shipment.
Calibration and Traceability - Providing the
Highest Confidence in Test
Agilent’s modular products are factory calibrated and most
modules are shipped with an ISO-9002, NIST-traceable
calibration certificate and a UK certification may be
available upon request. Agilent performs calibrations at its
owned service centers and offers the highest number of
RF parameter accreditations. Calibration services can be
performed:
• At one of Agilent's 46 worldwide service locations
• At your site by an Agilent expert
For some products, the calibration procedure used at the
Agilent service centers is also available in the N7800A
Calibration and Adjustment Software. It automates
calibration to save time, reduce cost and ensure consistent
quality results. The software also includes automated
adjustments whenever measurement performance is
outside acceptable limits.
The calibration status is maintained through the
"electronic calibration sticker" which can be accessed
programmatically or via the soft front panel. This utility
helps ensure your instrument is calibrated by managing
the calibration interval and providing messages regarding
instrument and module calibration status.
Easily Upgrade Your Equipment Capability
With selected modular products, you may upgrade options
such as memory, frequency range or modulation bandwidth
through a license key. This means you can upgrade your
equipment without shipping it to an Agilent facility. Simply
place an order for the upgrade which can be activated
online and installed via the instrument's soft front panel.
Self Test
A self test utility runs a set of internal tests which verifies
the health of the modules and reports their status.
14
PXI & AX Ie - INDUSTRY A W ARDS
Agilent's portfolio of PXI and AXIe chassis and modules received multiple industry awards since its introduction in
September 2010. The most recent awards, shown below, confirm that Agilent's modular portfolio is receiving marketplace
recognition and demonstrates excellence in creating value for customers.
Winners and finalists for these awards are considered the best in the industry. They set the pace through their innovation,
vision and technology leadership.
3
Test & Measurement World's
2011
15
PXI CHASS IS AND CONTROLLERS
To better fit with your footprint and performance needs, you have the choice between external desktop, laptop, or embedded Agilent controllers.
Product features
Chassis functionality
• 18 total slots including PXIe controller and timing module
slots
• 16 PXIe hybrid slots
• Up to 867 W total power and 42 W/slot cooling
Agilent M9018A PXIe Chassis
Chassis performance characteristics
• Advanced PCIe® switch fabric that operates up to Gen 2 speeds
• Twelve x4 and four x8 links to module slots
• Backplane speeds of up to a 4 GB/s data rate from external controller to PXIe module slots
• Innovative cooling design that allows chassis to fit into 4U of rack space in most cases
Multi-chassis configurations
NEW
The M9021A can be used with the M9018A PXIe Chassis to build multi-chassis systems. Up to four chassis can be connected
together depending on the controller and operating system used. Many different topologies are possible including cascade
and star. Two examples are shown below.
For more detailed configuration information, see: www.agilent.com/find/pxie-multichassis
Figure 1. Star configuration with M9036A Embedded Controller
and M9021A PCIe interface
Figure 2. Cascade configuration with External Controller and
M9021A PCIe interface
www.agilent.com/find/pxi-chassis
P XI ch assis a n d c o n tro lle rs
Select Agilent’s PXIe chassis when you require high-performance and configurability. The M9018A PXIe chassis has unparalleled performance and flexibility including PCI Express® Gen 2 performance, 16 PXI hybrid slots, x8 links to peripheral
slots, and an innovative cooling design that saves rack space and has lower maintenance costs.
PXI cha s s i s a nd c ont r o l l e r s
P XI ch assis a n d c o n tro lle rs
Chassis
M9018A
Description
Height
Type
# of slots
Number of
slots
Maximum data
bandwidth
System slot
interface
Power supply
Power per slot
PXIe Gen 2.0
Chassis
4U
PXIe 3U
18-slots
1 system
1 timing
16 hybrid
Module-to-module: 4
GB/s
System-to-backplane:
8 GB/s
Configurable:
1x8,
2x8,
4x4
867.5 W
System 140 W
PXI hybrid 42 W
PXI I/O and Computer Modules
Description
Type
# of slots
Processor
RAM (min/max)
HDD
Maximum data
bandwidth
Cable interface
System slot
interface
M9021A
PCIe® Cable
Interface
3U PXIe
1-slot
NA
NA
NA
4 GB/s
x8 Gen 2 PCIe
x8 Gen 2 PCIe
M9036A
PXIe Controller
3U PXIe
3-slots
Intel i5 520E
2.4 GHz
4 GB
8 GB option
160 GB
SSD
4 GB/s
N/A
2x8 or 4x4
PCIe Gen 2
External PC cards
Description
Type
# of slots
Maximum data
bandwidth
Cable interface
PC host interface
M9045B
PCIe ExpressCard Adapter: Gen 1
ExpressCard 34
1-slot
250 MB/s
x1 Gen 1 PCIe
x1 Gen 1 PCIe
M9048A
PCIe desktop PC Adapter: Gen 2,
Clock Isolation
PCIe x8 or x16
1-slot
4 GB/s
x8 Gen 2 PCIe
x8 Gen 2 PCIe
Driver information
Supported operating systems
M9018A: Microsoft Windows 7 (32/64-bit), Windows Vista (32/64-bit), Windows XP (32-bit)
M9036A: Microsoft Windows 7 (32/64-bit), Windows XP (32-bit)
Standard compliant drivers
IVI-COM, IVI-C, LabVIEW
Supported application development environments
(ADE)
M9018A: Visual Studio (VB.NET, C#, C/C++), LabVIEW, LabWindows/CVI, VEE
M9036A: Visual Studio (VB.NET, C#, C/C++), LabVIEW, LabWindows/CVI, MATLAB
Agilent IO Libraries
Includes: VISA Libraries, Agilent Connection Expert, IO Monitor
www.agilent.com/find/pxi-chassis
M9018A
Agilent M9018A
18-Slot PXIe Chassis
www.agilent.com/find/m9018a
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations (c ont'd)
• Aerospace and defense communications
Power supply output
• Electronics test
220-240VAC input - 867.5 W
100-120VAC input - 717.5 W
Power dissipation
System slot - 140 W max
User slot - 42 W max 1
• Semiconductor testing
System slot link configuration (selectable)
P r o d u c t D escr i p t i o n
The M9018A chassis delivers the ultimate flexibility,
compatibility, and performance. With 16 PXIe hybrid slots,
it allows the system designer to mix and match the number
and location of PXIe and hybrid PXIe-compatible modules.
The advanced PCIe® switch fabric can operate up to Gen
2 speeds and can be configured for optimal performance
with any PXIe controller. The innovative cooling design
allows the chassis to fit in 4U of rack space. When combined with the latest 1U rack-mounted computer, you can
build a powerful system using only 5U of rack space.
M a i n F e a tur e s and B e ne fi t s
2-link config for M9021A
1x8 (link 2 inactive)
2-link configuration
2x8
4-link configuration
4x4
Data bandwidth (max)
Slot-to-slot - 4 GB/s
System slot-to-user slots - 8 GB/s
1. Maximum per slot power dissipation at 55˚C with 15˚C temperature rise; requires:
a) that the chassis bottom is not blocked (1U rack space below or sitting on bench
with feet extended) or b) two air inlet modules in slots 9, 10, or 11, and a slot
blocker in empty controller slots. Module cooling can be impacted by each module’s
resistance to air flow.
Ordering Information
Model
Description
M9018A
PXIe chassis: 18-slot, 3U, 8 GB/s
Opt 900-932
Power cord options
Product features
Your benefit
16 hybrid slots
Eases system integration with
flexibility and compatibility
Gen 2 speeds as well as four x8 and
12 x4 links to module slots
Large data rate supports highperformance applications
Related products
Advanced PCIe switching
Provides configuration flexibility
M9021A
PCIe cable interface: Gen 2, x8
Innovative cooling design
Saves rack space and lowers
maintenance cost
M9036A
Embedded PXIe PC controller
M9045B
PCIe ExpressCard adaptor: Gen 1
867.5 W power supply
Provides power to spare for
application requirements
Y1200B
PCIe cable: x1 to x8, 2.0m (used with
M9045B)
M9048A
PCIe desktop PC adapter: Gen 2, x8
Y1202A
PCIe cable: x8, 2.0m (used with M9048A)
S p e c i f i c a ti o ns and C har act e r i st i cs
4
Accessories
Hardware
Y1212A
Slot blocker kit: 5 single slot
Size
4U
Y1213A
PXI EMC filler panel kit
Number of slots
18 total, 16 hybrid-compatible
PXI-1 and cPCI (J1 only), PXIe, PXI-H
Y1214A
Air inlet module kit
Y1215A
Chassis rack mount kit for M9018A
19
M9021A
Agilent M9021A
PCIe® Cable Interface
www.agilent.com/find/m9021a
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations and Charac teristic s
Hardware
• Aerospace and defense
• Communications
Size
1-slot 3U
PCIe link configuration
Gen 2 x8 link to primary M9018A
Gen 1 x8 link to secondary M9018A
or M9502A/M9505A in multi-chassis
configurations
Data bandwidth (max)
4 GB/s to external controller
4 GB/s to primary M9018A backplane
2 GB/s between chassis in multi-chassis
configurations
Front panel connector
x8 PCIe cable connector
Front panel indicators
LEDs for PCIe lane status
Power consumption
5 W (typical)
Cable length
Up to a 2 meter passive cable supported
• Electronics test
• Semiconductor testing
4
P r o d u c t D e scr i p t i o n
The M9021A PCIe cable interface provides a link between
the M9018A PXIe chassis and an external host computer.
It can also be used to link multiple M9018A together or
to link an AXIe chassis to the M9018A. Once installed in
the chassis and connected to the computer via a standard
PCIe cable, the M9021A provides a very high bandwidth
serial link between the devices. This link is transparent to
computer applications and allows direct control of PXI and
PXIe modules. The M9021A utilizes special features built
into the M9018A PXIe chassis and is not compatible with
the PXIe system slot in other PXIe chassis.
Ma i n F e a tur e s and B e ne fi t s
Ordering Information
Model
Description
M9021A
PCIe cable interface: Gen 2, x8
Related products
M9018A
PXIe chassis: 18-slot, 3U, 8GB/s
Product features
Your benefit
M9045B
PCIe ExpressCard adaptor: Gen 1
Gen 2 speeds and x8 PCIe links
Large data rate supports highperformance applications
Y1200B
PCIe cable: x1 to x8, 2.0m (used with M9045B)
M9048A
PCIe desktop PC adapter: Gen 2, x8
Standard PCIe over cable
Use with any computer with an
x8 PCIe interface
Y1202A
PCIe cable: x8, 2.0m (used with M9048A)
Transparent operation with
application software
Provides ease of installation
Target and Host modes
Enables large PXIe systems or
mixed PXIe-AXIe systems with a
single controller
20
Connector compatibility: M9018A
M9036A
Agilent M9036A
PXIe Embedded PC Controller
www.agilent.com/find/m9036a
I n d u s tr i e s and A p p l i cat i o ns
Hardware
• Aerospace/defense
• Communications
• General purpose applications
• Electronic functional test
P r o d u c t D e scr i p t i o n
The Agilent M9036A is an embedded PXIe PC controller
which enables a compact platform solution. With the
2-link, 2x8 Gen 2 backplane configuration, it is an ideal
match for the Agilent M9018A PXIe chassis. This three-slot
module easily integrates into hybrid test systems using
GPIB, USB, and LAN with the built-in front panel interfaces. Built upon a mid-performance Intel Core i5 dual-core
processor with Hyper-Threading Technology, the M9036A is
designed for applications in multi-tasking environments.
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefits
Gen 2 PCIe backplane switches
Enables high-speed peer-to-peer
data transfers between M9018A
peripheral slots
®
Spec ific ations and Charac teristic s
Intel Core I5 dual-core processor
Ideal for applications in multitasking environments
Preloaded with Agilent I/O libraries
and operating system
Reduces test system
development time
Designed for PXIe systems
Provides choice between
embedded and external
controllers
Solid-state drive (SSD)
Improves mechanical reliability
Size
3-slot, PXIe system module
CPU
Intel i5-520E dual-core at 2.4 GHz
Storage
Type
Size
2.5” SATA II SSD
160 GB
Memory
4 GB standard, 8 GB optional
8 GB maximum
PXIe PCIe link
configuration
2x8 or 4x4 (automatically configured based
on chassis configuration)
PXIe PCIe data
bandwidth (max)
2 GB/s max to/from the processor
4 GB/s max between PCIe backplane links
(2-link mode)
Front panel
connections
USB (4), 10/100/1000 LAN (2), VGA
2028x1536 @75 Hz (requires DVI-VGA
adapter), DVI-I up to 1920x1200 @60 Hz,
GPIB (Micro-D 25-pin), ExpressCard 34 mm
slot, PXI trigger in/out (SMB)
4
Ordering Information
Model
Description
M9036A
PXIe embedded PC controller, 4 GB RAM
M9036A-M08
Memory upgrade from 4 GB RAM to 8 GB
RAM
M9036A-WE6
Windows Embedded Standard 7 Operating
System (64-bit)
M9018A
18-slot PXIe chassis
Other options
M9036A-WE3
Windows Embedded Standard 7
Operating System (32-bit)
M9036A-WXP
Downgrade to Windows XP Operating
System (32-bit)
Chassis slot compatibility: PXIe system module slot
(with two or more controller expansion slots)
21
M9045B
Agilent M9045B
PCIe® ExpressCard Adapter
www.agilent.com/find/m9045b
I n d u s tr i e s and A p p l i cat i o ns
Hardware
• Aerospace and defense
• Communications
• Electronics test
• Semiconductor testing
4
P r o d u c t D e scr i p t i o n
The M9045B is a PCIe interface card that can be used
with an Agilent AXIe chassis, such as the M9502A/5A, or
a PCIe cable interface, such as the M9021A.
®
This adapter uses the ExpressCard 34 format typically
found in laptop computers. It provides a x1 Gen 1 link to
the computer (One Stop OSS-PCIE-HIB2-EC-x1).
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefit
ExpressCard format and low power
consumption
Provides a transportable
solution
Standard PCIe over cable
Transparent operation with
application software
22
Spec ific ations and Charac teristic s
Allows use with any computer
with PCIe ExpressCard
interfaces
Delivers ease of installation
Card format
PCIe ExpressCard 34
Dimensions
34 mm (1.34 in) x 110.8 mm (4.36 in)
Number of PC slots
1
Data bandwidth (max)
250 MB/s
Connector
x1 PCIe cable connector
Cable length
Up to a 7-meter passive cable supported
For more complete specifications and manuals, visit the OSS Web
site: http://www.onestopsystems.com/
This product comes with a one year warranty and can be returned
to either Agilent or OSS for warranty service.
Ordering Information
Model
Description
M9045B
PCIe ExpressCard adapter: Gen 1
Related Products
M9021A
PCIe cable interface: Gen 2, x8
M9502A
2-slot AXIe chassis
M9505A
5-slot AXIe chassis
Accessories
Y1200B
PCIe cable: x1 to x8, 2.0m (used with
M9045B)
M9048A
Agilent M9048A
PCIe® Desktop PC Adapter
www.agilent.com/find/m9048a
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations and Charac teristic s
• Aerospace and defense
Hardware
• Wireless communications
Card format
PCIe half-card format
(half-height and half-width)
Computer expansion
slot compatibility
x8 and x16, Gen 1, 2, or 3*
Dimensions
55 mm (2.2 in) x 114 mm (4.5 in)
Number of PC slots
1
Data bandwidth (max)
4 GB/s (Gen 2 x8 PC slot)
Connector
x8 PCIe IPASS cable connector
Card indicators
LEDs for link status and transport mode
Power consumption
7 W (typ)
Cable length
Up to 2-meter passive cable
PCI bracket
Includes both low profile and standard
profile brackets
Operating temperature
0 C - 55 C
• Electronics test
• Semiconductor testing
P r o d u c t D escr i p t i o n
The M9048A PCIe® desktop PC adapter provides a highperformance (Gen 2 x8) link between a host PC and PXIe or
AXIe chassis.
The M9048A utilizes a PCIe switch and clock isolation to
provide a high-quality clock source driven down the PCIe
cable to the PXIe or AXIe chassis. As a result, the adapter
always provides the same, high-performance Gen 2 link,
independent of the PC. It can also operate in most Gen 3
PC slots because the PC can train to Gen 2. The adapter
is compatible with desktop or rackmount computers that
have either x8 or x16 PCIe expansion slots (mechanical). It
connects directly to the M9502A/5A AXIe or M9018A PXIe
chassis with a Y1202A PCIe cable.
M a i n F e a tur e s and B e ne fi t s
* The M9048A is designed to be compatible with most Gen 3 PCIe PC
slots, but the PC will train to Gen 2.
O r d er in g I n fo r m a t io n
Model
Description
M9048A
PCIe desktop PC adapter: Gen 2, x8, clock
isolation
Related products
Product features
Your benefit
M9018A
PXIe chassis: 18-slot, 3U, 8GB/s
PC host clock isolation
Provides superior computer
compatibility
M9021A
PCIe cable interface: Gen 2, x8
M9045B
PCIe ExpressCard adapter
M9502A
AXIe chassis: 2-slot with integrated system
module
M9505A
AXIe chassis: 5-slot with integrated system
module
IDT PCIe switch
Compatibility with PCs that
have Gen 3 PCIe slots
Gen 2 x8 PCIe capability
Enables high-performance applications
Standard PCIe over cable
Connects a PXIe or AXIe chassis to
PCs with expansion slots
Transparent operation with
application software
Delivers ease of installation
4
Accessories
Y1202A
PCIe cable: x8, 2.0m
23
PXI Bit E rror R a t e t es t e r s ( b e r t s )
Product features and your benefits
• Eye diagram, mask analysis and jitter testing in a single instrument
• Low cost and high throughput–ideal for manufacturing test environments
• Significantly smaller than a conventional BERT
• Jitter bathtub display
• Error injection: single error or error rate injection
• Differential data generation and analysis
Agilent PXIT Family of Modules
Agilent N2100B Digital Communication
Analyzer soft front panels
www.agilent.com/find/pxi-ber
P XI bit e r r or ra t e t e s t e rs
The Agilent PXI modules address the test of photonic and conventional components in the telecommunications, data communications and computing markets for bit error rate, eye diagram analysis, mask and jitter
testing. For the manufacturing industry, this unique test solution combines a modular Bit Error Ratio Tester
(BERT) and a Digital Communications Analyzer (DCA), providing a very wide bit rate coverage and excellent
performance. Products include a Bit Error Ratio Tester, a Digital Communications Analyzer, a Pattern Generator,
and a PXI Synthesizer all suitable for bitrates up to 10.3125 Gb/s.
PXI bit error ra t e t es t e r s
P XI b it er ro r r a t e t e s t e rs
RF Signal Generators (Signal Source)
Description
N2099A
Type
# of slots
Frequency
range
Output power
Phase noise
(20 kHz offset)
Switching
speed
Output Power
accuracy
Software
applications
PXI-H
2-slot
Optional
5.25 ± 1 GHz or
10.5 ± 1 GHz
Min +8 dBm
(4, 5, 6 GHz);
min +6 dBm
(9, 10, 11 GHz)
500 MHz
100 ms
±3 dB
variation over
temperature,
frequency
N/A
RF Synthesizer
and Clock
Source for
N2102B, N2101B
Digital Communication Analyzer (DCA)
N2100B
Description
Type
# of slots
Digital
Communication
Analyzer
PXI-H
4-slot
Electrical input
bandwidth
Optial input
Sample
rate
1 channel,
single ended AC
coupled,
9.5 GHz (char)
62.5/125 µm fiber,
750–1650 nm,
10.3125 Gb/s
160 MS/s
Clock input
Clock
recovery
10 MHz –
11.318 GHz
(char.),
0.5 to 1 V pp
<2.7 Gb/s
Clock input
voltage
range
500 mV to
1 V pp
Bit Error Rate Testers (BERTS)
N2101B
Description
Type
# of slots
Bit rate
PRBS patterns
Data patterns
Output voltage
range
Outputs
External clock
input
Bit Error
Ratio Tester
PXI-H
3-slot
155 Mb/s to
10.3125 Gb/s
2n - 1, n = 7, 9, 11,
15, 23, 31
K28.5, K28.7,
CRPAT,
user-loadable
2 kbits
250 mV to
1 V pp
1x
differential
ports
500 MHz to
10.7 GHz
Pattern Generator
N2102B
Description
Type
# of slots
Bit rate
range
PRBS patterns
Data patterns
Output voltage
range
Outputs
Clock input
voltage range
Pattern
Generator
PXI-H 2-slot
622 Mb/s
to
10.3125 Gb/s
2n - 1, n = 7, 9,
11, 15, 23, 31
K28.5, K28.7,
CRPAT, userloadable 2 kbits
250 mV to 1
V pp
1x
differential
ports
500 mV to
1 V pp
Driver information
Supported operating systems
Microsoft Windows 7 (32/64-bit), Windows XP (32-bit)
Standard compliant drivers
IVI-COM, IVI-C, LabVIEW, MATLAB
Supported application development environments (ADE)
Visual Studio (VB.NET, C#, C/C++), VEE, LabVIEW, LabWindows/CVI, MATLAB
Agilent IO Libraries
Includes: VISA Libraries, Agilent Connection Expert, IO Monitor
The N2099B, N2100B, N2101B, N2102B and their accompanying software fully comply with PXI specifications. The included Windows application
enables the user to control the instrument without any software development required. An ActiveX Control makes integration into custom applications
easy. The software suite provided with the N2102B enables easy setup and accelerates the time to first measurement.
www.agilent.com/find/pxi-ber
N2099A
Agilent N2099A
Synthesizer
www.agilent.com/find/pxi-ber
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations and Charac teristic s
• Transceiver Test
Hardware
• Telecommunication Equipment Test
Size
2-slot module
• Fibre Channel, Ethernet, PON, Parallel Optics
Output center frequency
• Multi-port system testing
5.25 GHz (option N2099A-052),
10.5 GHz (option N2099A-105)
Frequency tuning range
±1.0 GHz
• High port count burn-in test
Output power
+8 dBm
(4, 5 and 6 GHz, characteristic)
+6 dBm
(9, 10 and 11 GHz,
characteristic)
P r o d u c t D escr i p t i o n
The N2099A PXI synthesizer is tunable over a 2 GHz range
and includes synchronous dual RF outputs. There are two
options available that cover different frequency ranges
depending on the required application.
The N2099A is the ideal clock source for the N2102B.
Power variation over
temperature/frequency
±3 dB
Switching speed, 100 MHz
step
100 ms typical
External reference oscillator
output frequency (TCXO)
10 MHz
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefit
Two frequency ranges available
between 4.25 and 11.5 GHz
Coverage of an extended
range of test applications
10 MHz clock output and two
synchronous RF outputs
Provide clock or reference
signals to multiple other
modules, e.g. BERTs or
Pattern Generators
Permanent magnet YIG
(PMYTO)
based synthesizer
Excellent phase noise
performance
Non-volatile storage of set
frequency – unit powers up at
previously set frequency
Avoids operator errors
Connector compatibility: cPCI, PXI-H, PXI-1
Ordering Information
Model
Description
N2099A
PXI Synthesizer
N2099A-052
4.25 GHz to 6.25 GHz
N2099A-105
9.5 GHz to 11.5 GHz
Related products
N2100B
PXI Digital Communication Analyzer
N2101B
PXI Bit Error Ratio Tester
N2102B
PXI Pattern Generator
27
5
N2100B
Agilent N2100B
Digital Communication Analyzer
www.agilent.com/find/pxi-ber
I n d u s tr i e s and A p p l i cat i o ns
• Test of Optical and Electrical Transceivers
• Telecommunication Equipment Test
• Fibre Channel, Ethernet, PON, Parallel Optics
• Multi-port system testing
• High port count burn-in test
5
P r o d u c t D escr i p t i o n
The N2100B PXI DCA combines the benefits and measurement capabilities of a real time scope with the bandwidth
of a sampling scope, using a coherent patented vector
undersampling technique. The N2100B performs accurate
eye diagram analysis to characterize the quality of transmitters from 155 Mb/s to 10.3125 Gb/s.
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefit
PON and 10 GigE filters
available
Extended test capabilities
Smart Post Processing
Allows optical transceiver
manufacturers increase
throughput
ER Correction Factor
Enables even tighter
correlation with other
instruments
Eye diagram, mask and jitter
testing in a single instrument
Wide optical bandwidth
coverage from 750 nm to
1650 nm
Allowing DUT’s quality
assessment, control and
binning
Cover test of optical
transmitters for
telecommunication and data
communication use
Connector compatibility: cPCI, PXI-H, PXI-1
28
Spec ific ations and Charac teristic s
Hardware
Size
4-slot module
Electrical input
1 channel, single ended
AC coupled, 1 V pp (max)
BW of electrical input
9.5 GHz (characteristic)
Optical input
62.5/125 μm fiber,
750—1650 nm
BW of optical input
10.3125 Gb/s (option 210)
Sample rate
160 Ms/s
Waveform acquisition
1024 points per acquisition,
max. 1024 acquisitions
Pattern acquisition mode
Max. 2047 bits pattern length,
128 points per bit, fixed
Clock recovery
<2.7 Gb/s
Clock input frequency range
10 MHz to 11.318 GHz (char.)
Clock input voltage range
0.5 to 1 V pp
Ordering Information
Model
Description
N2100B
PXI Digital Communication Analyzer
Must choose any 4 different filter rates:
N2100B-300
PXI DCA 155 Mb/s to 10.3125 Gb/s
Options
Option 110
155 Mb/s
Option 120
622 Mb/s
Option 130
1.063 Gb/s
Option 140
1.25 Gb/s
Option 150
2.125 Gb/s
Option 160
2.488/2.5 Gb/s
Option 180
3.125 Gb/s
Option 190
4.25 Gb/s
Option 193
5.0 Gb/s
Option 195
6.25 Gb/s
Option 197
8.5 Gb/s
Option 210
9.95/10.3125 Gb/s
Related products
N2101B
PXI Bit Error Ratio Tester
N2102B
PXI Pattern Generator
N2099A
PXI Synthesizer
N2101B
Agilent N2101B
10.3125 Gb/s Bit Error Ratio Tester
www.agilent.com/find/pxi-ber
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations and Charac teristic s
• Transceiver Test
Hardware
• Telecommunication Equipment Test
Size
3-slot module
• Fibre Channel, Ethernet, PON, Parallel Optics
Pattern generator output
Jitter
2.5 ps RMS (max),
1.5 ps RMS (characteristic)
Pattern generator output
voltage range
250 mV to 1 V
Rise/ Fall times (20-80%)
25 ps (max),
22 ps (characteristic)
P r o d u c t D escr i p t i o n
Error detector input
(differential)
50 mV to 2 V range,
50 mV sensitivity
The N2101B PXI 10.3125 Gb/s BERT consists of a high
accuracy clock source, data pattern generator, and error
detector. It will automatically perform bit error ratio analysis to characterize the quality of devices at 12 standard
internal rates from 155 Mb/s to 8.5 Gb/s.
In conjunction with a synthesizer such as the Agilent
N2099A, the N2101B BERT can operate at any rate up to
10.3125 Gb/s.
External clock input
500 mV to 1 V (characteristic),
500 MHz to 10.3125 GHz
Divided clock rate outputs
1, 2, 4, 8 & 128
(output on separate port)
Pattern generation
PRBS 2n -1, (n=7, 9, 11, 15, 23, 31);
K28.5, K28.7 and CR Pat;
User defined patterns with 2048
bits max length or 16 KB if pattern
length is divisible by 64.
• Multi-port system testing
• High port count burn-in test
M a i n F e a tur e s and B e ne fi t s
Ordering Information
Model
Description
PXI Bit Error Ratio Tester
N2101B-300
155 Mb/s to 10.3125 Gb/s module
Product features
Your benefit
N2101B
Significantly smaller than a
conventional BERT
Fits well in space constrained
test environments
Related products
Easily combined with DCA,
Complete, integrated, modular
Synthesizer, Pattern Generator PXI transceiver test solution
or multiple BERT modules in a
PXI chassis
Pattern generation and BER
measurements for rates from
155 Mb/s to 8.5 Gb/s
Same test platform for a wide
number of formats, including
Fibre Channel, GbE, Xaui, PCI
Express®, OC196/STM64
5
N2100B
PXI Digital Communication Analyzer
N2102B
PXI Pattern Generator
N2099A
PXI Synthesizer
Connector compatibility: cPCI, PXI-H, PXI-1
29
N2102B
Agilent N2102B
Pattern Generator
www.agilent.com/find/pxi-ber
I n d u s tr i e s and A p p l i cat i o ns
5
Spec ific ations and Charac teristic s
• Transceiver Test
Hardware
• Telecommunication Equipment Test
Size
2-slot module
• Fibre Channel, Ethernet, PON, Parallel Optics
Bit rate operation
622 Mb/s to 10.3125 Gb/s
• Multi-port system testing
Output rise/fall time
(20% - 80%)
25 ps (max),
22 ps (characteristic)
• High port count burn-in test
Output intrinsic jitter
2.5 ps RMS (max),
1.5 ps RMS (characteristic)
Output voltage range
250 mV to 1 V pp
Output voltage resolution
5 mV
Pattern trigger/clock output
voltage
1 V pp (characteristic)
Clock input voltage range
500 mV to 1 V pp
(characteristic)
P r o d u c t D e scr i p t i o n
The N2102B PXI Pattern Generator is capable of
generating a number of low jitter patterns at rates up to
10.3125 Gb/s using an externally supplied clock. ActiveX
Controls allow for easy software development and a
graphical user interface is provided for manual operation of
the module.
M a i n F e a tur e s and B e ne fi t s
Product features
Ordering Information
Model
Description
N2102B
PXI Pattern Generator
N2102B-300
622 Mb/s to 10.3125 Gb/s
Related products
Your benefit
N2100B
PXI Digital Communication Analyzer
PRBS generations 2 – 1,
(n = 7, 9, 11, 15, 23, 31);
User defined patterns with
2048 bits max. length or
16 KBz if pattern length is
divisible by 64
Flexible, custom pattern
generation
N2101B
10.3125 Gb/s Bit Error Ratio Tester
N2099A
PXI Synthesizer
2-slot PXI module
Minimum rack space
Clock input
Driven by the N2101B’s clock
output, the N2102B serves as
a detached stimulus for the
BERT
n
30
Connector compatibility: cPCI, PXI-H, PXI-1
PXI d at a a c qui s i t i on a n d s wi t c hi n g
The PXI data acquisition and switch modules deliver modular, high-performance signal connections in the standard PXI
platform. Agilent offers a wide selection of performance such as high-speed, 500 usec multiplexer relays, high-power,
300 W general purpose switches and high-density 256 2-wire cross point matrix modules. Additionally, RF and microwave
switch technology delivers low insertion loss and VSWR for excellent RF signal integrity and dynamic range when routing
RF signals into your measurement equipment.
The new microwave PXI hybrid switch modules (product
numbers M9155CH40, M9156CH40 and M9157CH40)
operate from DC to 40 GHz and have a guaranteed 0.03 dB
insertion loss repeatability through the operating life of 5
million cycles (typical life of 10 million cycles).
NEW
The new 40 GHz PXI switches offer:
•
•
Reduced downtime for re-calibration for improved test
efficiency
Unmatched isolation: 65 dB at 40 GHz
Which Data Acquisition and Switch Module is right for you?
• Select and compare modules
• Define a switching solution
• Compare switch platforms
• Select and compare switch and control modules
www.agilent.com/find/pxi-switch
P XI D at a Acq ui si ti o n a nd S wi t chi ng
Whether you use switching to route signals for design verification applications or complex automated function test systems, Agilent has the data acquisition and switch platforms that will allow you to get the job done faster with confidence
in your measurement results.
PXI d at a a c qui s i t i on a n d s wi t c hi n g
P XI Dat a A cqu is i ti o n a nd S wi t ch ing
General Purpose Switches
The PXI general purpose switch modules deliver fast, reliable switching in a variety of configurations.
Key features
•
•
•
Independent, single-pole, double-throw (Form C) or single-pole, single-throw (form A) switches in a single module
High-speed , long-life reed relays
High-power electromechanical relay, handling up to 300 W/2500 VA
General Purpose Switches
Description
Type
# of slots
Channels
Switching
speed
(typical)
Max voltage
Current
switch & carry
Relay type
Connectors
M9130A
SPDT switch
PXI
1-slot
26 Form C
2.7 ms
250 Vrms
2 A/2 A
Armature
78D connector block or cable
M9131A
SPDT switch
PXI
1-slot
64 Form C
2 ms
100 Vrms
0.25 A/1 A
Reed
200LFH connector block or
cable
M9132A
SPST switch
PXI
1-slot
50 Form A
0.35 ms
100 Vrms
1 A/1 A
Reed
200LFH connector block or
cable
M9133A
SPST switch
PXI
1-slot
100 Form
A
0.35 ms
100 Vrms
1 A/1 A
Reed
200LFH connector block or
cable
M9135A
SPST power
relay
PXI
1-slot
20 Form A
10 ms
250 Vrms
125 Vdc
5 A/5 A
Armature
20MSM connector block or
cable
Matrix Switches
The PXI matrix switch modules deliver medium to high density switching of multiple channels in a single instance.
Key features
•
•
•
Up to 256 two-wire cross points can be configured in a single module
High-speed, long life, reed relays (up to 100 VDC/100 VAC, 20 W
Higher power electromechanical relays (up to 125 VDC/125 VAC, 60 W)
Matrix Switches
Description
Type
# of slots
Channels
Switching
speed
Max
voltage
Current
switch & carry
Relay type
Connectors
M9120A
Matrix
switch
PXI
1-slot
4 x 32, 2-wire
3 ms
100 Vrms
2 A/2 A
Armature
78 Dsub connector
block or cable
M9121A
High Density
Matrix
switch
PXI
1-slot
4 x 64, 2-wire
< 1 ms
100 Vrms
0.5/0.5 A
Reed
200 LFH connector
block or cable
M9122A
Matrix
switch
PXI
1-slot
8 x 32, 1-wire
3 ms
100 Vrms
2 A/2 A
Armature
50 Dsub connector
block or cable
32
www.agilent.com/find/pxi-switch
PXI d at a a c qui s i t i on a n d s wi t c hi n g
The PXI multiplexer modules deliver high-speed signal routing for many channels to a single point and are ideal for routing
multiple analog signals to a measurement device.
Key features
•
•
•
Available in 1-wire or 2-wire configurations
High-speed, long-life, reed relays (up to 100 VDC/100 VAC, 20 W)
Higher power electromechanical relays (up to 100 VDC/100 VAC, 60 W)
Multiplexers
Description
Type
# of slots
Channels
Switching
speed (typical)
Max
voltage
Current switch
and carry
Relay type
Connectors
M9101A
High-density
multiplexer
PXI
1-slot
64 channels,
2-wire
1,000 μs
100 Vrms
0.5 A/1.0 A
Reed
200LFH connector
block or cable
M9102A
High-density
multiplexer
PXI
1-slot
128 channels,
1-wire
1,000 μs
100 Vrms
0.5 A/1.0 A
Reed
200LFH connector
block or cable
M9103A
High-density
multiplexer
PXI
1-slot
99-channels,
2-Wire
4.5 ms
100 Vrms
1 A/1 A
Armature
200LFH connector
block or cable
Data Acquisition
The M9216A is a high voltage, high channel count data acquisition module. The M9216A High Voltage DAQ is capable of
parallel measurement of positive voltages that fluctuate between very low and very high levels.
Key features:
• High voltage range, high channel count
• Simultaneous dual measurement range for each channel
• Auxiliary outputs for additional measurement
Data Acquisition
Description
M9216A
High voltage DAQ
Type
# of slots
Channels
Scan Channel
Seconds
Min Voltage
Max Voltage
Max Current
PXI
2-slot
32 channels
250 kSa.s
1 mV
100 V
0.5 A
www.agilent.com/find/pxi-switch
33
P XI Dat a A cqu is i ti o n a nd S wi t ch ing
Multiplexer Modules
PXI d at a a c qui s i t i on a n d s wi t c hi n g
P XI Dat a A cqu is i ti o n a nd S wi t ch ing
RF Switches
The PXI RF switch modules deliver high-performance, high-density, switching of up to 3 GHz and are available in multiple
configurations.
Key features
•
•
•
Low insertion loss and VSWR
Excellent RF signal integrity and dynamic range
Repeatable RF performance
RF Switches
Description
Type
# of slots
Frequency
range
Insertion loss
(typical)
Isolation (typical)
VSWR
(typical)
Impedance
Connectors
M9128A 8 x 12
matrix switch
PXI
1-slot
300 Mhz
2 dB at 300 MHz
40 dB at
300 MHz
2:1 at 300 MHz
50 Ω
SMB male connectors
M9146A Dual 1 x 4
multiplexer
PXI
1-slot
3 GHz
0.8 dB at 3 GHz
45 dB at 3 GHz
< 1.3:1 at 3 GHz
50 Ω, off
channel
termination
SMB male connectors
M9147A Quad 1 x 4
multiplexer
PXI
1-slot
3 GHz
1 dB at 3 GHz
40 dB at 3 GHz
< 1.4:1 at 3 GHz
50 Ω
SMB male connectors
M9148A 1 x 8
multiplexer
PXI
1-slot
3 GHz
0.8 dB at 3 GHz
40 dB at 3 GHz
< 1.25:1 at 3 GHz
50 Ω
SMB male connectors
M9149A 1 x 16 high
density
multiplexer
PXI
1-slot
3 GHz
1.2 dB at 3 GHz
40 dB at 3 GHz
< 1.5:1 at 3 GHz
50 Ω
SMB male connectors
M9150A Dual 1 x 4
multiplexer
PXI
1-slot
3 GHz
1 dB at 3 GHz
45 dB at 3 GHz
< 1.55:1 at 3 GHz
75 Ω
SMB male connectors
M9151A Quad 1 x 4
multiplexer
PXI
1-slot
3 GHz
1.1 dB at 3 GHz
40 dB at 3 GHz
< 1.6:1 at 3 GHz
75 Ω
SMB male connectors
M9152A 1 x 8
multiplexer
PXI
1-slot
3 GHz
1 dB at 3 GHz
45 dB at 3 GHz
< 1.5:1 at 3 GHz
75 Ω
SMB male connectors
M9153A 1 x 16
multiplexer
PXI
1-slot
3 GHz
1.2 dB at 3 GHz
40 dB at 3 GHz
< 1.55:1 at 3 GHz
75 Ω
SMB male connectors
34
www.agilent.com/find/pxi-switch
PXI d at a a c qui s i t i on a n d s wi t c hi n g
The new Agilent PXI hybrid switch module series operate from a frequency range of DC to 40 GHz, and are used in applications where a rugged switching module is needed in high-density switching systems.
Key features
•
•
•
Exceptional guaranteed 0.03 dB insertion loss repeatability
High isolation, low SWR
Long operating life of up to 10 million cycles
Microwave Switches
Description
Type
# of slots
Frequency Insertion loss
range
Isolation
VSWR
Impedance Connectors
M9155C
Dual SPDT
switch
PXI-H
1-slot
DC to
26.5 GHz
0.25 dB + 0.027 x f
DC: 0.25 dB
8 GHz: 0.47 dB
12.4 GHz: 0.58 dB
18 GHz: 0.74 dB
26.5 GHz: 0.96 dB
DC: 110 dB
8 GHz: 92 dB
12.4 GHz: 82 dB
18 GHz: 70 dB
26.5 GHz: 50 dB
DC to 8 GHz: 1.25
8 to 18 GHz: 1.45
18 to 26.5 GHz: 1.70
50 Ω
3.5 mm (f)
M9156C
Dual transfer
switch
PXI-H
2-slots
DC to
26.5 GHz
0.2 dB + 0.025 x f
DC: 0.20 dB
8 GHz: 0.40 dB
12.4 GHz: 0.51 dB
18 GHz: 0.65 dB
26.5 GHz: 0.86 dB
DC: 110 dB
8 GHz: 94 dB
12.4 GHz: 85 dB
18 GHz: 74 dB
26.5 GHz: 57 dB
DC to 2 GHz: 1.10
2 to 4 GHz: 1.15
4 to 12.4 GHz: 1.25
12.4 to 20 GHz: 1.40
20 to 26.5 GHz: 1.65
50 Ω
SMA (f)
M9157C
Single SP6T
switch
PXI-H
3-slots
DC to
26.5 GHz
0.3 dB + 0.015 x f
DC: 0.3 dB
8 GHz: 0.42 dB
18 GHz: 0.57 dB
26.5 GHz: 0.70 dB
DC to 12 GHz: 90 dB
12 to 15 GHz: 70 dB
15 to 20 GHz: 65 dB
20 to 26.5 GHz: 60 dB
DC to 8 GHz: 1.35
8 to 18 GHz: 1.45
18 to 26.5 GHz: 1.70
50 Ω
SMA (f)
M9155CH40
Dual SPDT
switch
PXI-H
1-slot
DC to
40 GHz
DC to 26.5 GHz:
0.2 dB + 0.023 x f
26.5 GHz to 40 GHz:
0.75 dB + 0..23 x f
40 GHz: 1.67 dB
DC to 26.5 GHz:
110 - 2.25f
26.5 GHz to 40 GHz:
50 dB
DC to 4 GHz: <1.10
4 to 26.5 GHz: <1.30
26.5 to 40 GHz: <1.50
50 Ω
2.92 mm (f)
M9156CH40 Dual transfer
switch
PXI-H
2-slots
DC to
40 GHz
0.2 dB + 0.025 x f
DC to 26.5 GHz:
120 dB - 2 x f (GHz)
26.5 GHz to 40 GHz:
60 dB
DC to 12.4 GHz: 1.3
12.4 to 25 GHz: 1.4
25 to 40 GHz: 1.7
50 Ω
2.92 mm (f)
M9157CH40
PXI-H
3-slots
DC to
40 GHz
DC to 26.5 GHz:
0.3 dB + 0.015 x f
DC to 12 GHz: 100 dB
12 to 15 GHz: 80 dB
15 to 20 GHz: 70 dB
20 to 40 GHz: 65 dB
DC to 4 GHz: 1.3 max
4 to 12.4 GHz: 1.35 max
12.4 to 18 GHz: 1.5 max
18 to 26.5 GHz: 1.7 max
26.5 to 40 GHz: 1.95
max
50 Ω
2.92 mm (f)
Single SP6T
switch
40 GHz: 1.2 dB
26.5 to 40 GHz:
0.030 f - 0.1 dB
www.agilent.com/find/pxi-switch
35
P XI D at a Acq ui si ti o n a nd S wi t chi ng
Microwave Switches
PXI dat a a c qui s i t i on a n d s wi t c hi n g
P XI Dat a A cqu is i ti o n a nd S wi t ch ing
PXI Attenuator/Switch Drivers
Integrate your external programmable attenuators and switches into your test system, and maximize the PXI chassis slot
utilization using PXI switch drivers.
Key features
•
•
Dual voltage supply for compatibility with most switches
Soft front panel provides a dynamic view and control of the connected attenuators or switches
PXI Attenuator/Switch Drivers
Description
M9170A Attenuator/Switch Driver module
Type
Voltage
# of slots
Drive mode
PXI 1-slot 5V, 24 V
Pulsed and
continuous
Drive
# of Switches
Most switches/attenuators Up to 12 external
available today
SPDT switches
Cables
6 options
available
Driver information
Supported operating systems
Microsoft Windows 7 (32/64-bit), Windows Vista (32/64-bit), Windows XP (32-bit)
Standard compliant drivers
All except RF switches: IVI-COM, IVI-C, LabVIEW, MATLAB
RF switches: IVI-COM, IVI-C, LabVIEW
Supported application development environments (ADE)
Visual Studio (VB.NET, C#, C/C++), VEE, LabVIEW, LabWindows/CVI, MATLAB
Agilent IO Libraries
All except MW switches, M9170A & M9216A: VISA Libraries, Agilent Connection Expert,
IO Monitor
www.agilent.com/find/pxi-switch
Multiplexer
Switches
Agilent PXI
Multiplexer Switch Modules
www.agilent.com/find/pxi-switch
I n d u s tr i e s and A p p l i cat i o ns
• Aerospace and defense
Spec ific ations and Charac teristic s
Hardware
• Automotive
• Electronic test
• Medical
• Semiconductor
P r o d u c t D e scr i p t i o n
The PXI multiplexer modules deliver high-speed signal
routing of many different channels to a single point, and
are ideal for routing multiple analog signals to a measurement device in Automated Test Environments (ATE) or data
acquisition systems.
Ma i n F e a tur e s and B e ne fi t s
Product features
Your benefit
High-speed, long-life reed relays
or higher power EM relays
Get the performance you need
with 500 usec switches or up to
60W per channel
Modules operate in break-beforemake mode
Ensure no two points are
connected at the same time
Up to 128 channels in a single
module
Scan many points in a compact
space
Software drivers support the
most common programming
environments
Work in your environment of
choice and reduce development
time
Optional connector block,
soft front panels, and Agilent
Connection Expert
Fast and easy installation and
configuration
Chassis slot compatibility: cPCI (J1), PXI-1, PXIe Hybrid
M9101A
M9102A
M9103A
Channels
64
128
99
Switch type
2-wire, reed
1-wire,
reed
2-wire,
armature
Max volts
(CAT 1)
100 Vrms
Max current
switch/carry
0.5A/1.0A
0.5A/1.0A
1A
Max power (nom)
10 W
10 W
60 W
Bandwidth (nom)
5 MHz
5 MHz
1 MHz
Connectors
200 LFH
6
Ordering Information
Model
Description
M9101A
PXI high-density multiplexer: 64-ch, 2-wire,
100V/1.0A, reed relays
M9102A
PXI high-density multiplexer: 128-ch, 1-wire,
100Vrms/1.0A, reed relays
M9103A
PXI high-density multiplexer: 99-ch, 2-wire,
100Vrms/1A, armature relays
Related products
M9018A
18-slot PXIe chassis
M9021A
PCIe® cable interface
M9132A
50-ch SPST general purpose switch
M9187A
32-ch digital I/O
Accessories
Y1182A
PXI connector block: 200-pin, shielded, male
(recommended)
Y1189A
PXI connector cable: 200-pin, LFH male to four 50
pin Dtype female connectors, 1Meter
Y1190A
PXI connector cable: 200-pin, LFH male to four 50
pin Dtype female connectors, 2Meter
37
Matrix Switches
Agilent PXI
Matrix Switch Modules
www.agilent.com/find/pxi-switch
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations (c ont'd)
• Aerospace/defense
• Automotive
• Electronic test
• Medical
P r o d u c t D escr i p t i o n
The PXI matrix switch modules deliver medium- to highdensity switching of multiple channels in a single instance.
Any row can be connected to any column—ideal for
routing multiple signals between the device under test and
instruments.
Ma i n F e a tur e s and B e ne fi t s
Product features
Your benefit
Up to 256 1-wire crosspoints
Connect multiple points for highpin-count applications
Software drivers support the
most common programming
environments
Work in your environment of
choice and reduce development
time
Optional connector block,
soft front panels, and Agilent
Connection Expert
Fast and easy installation and
configuration
S p e c i f i c a ti o ns and C har act e r i st i cs
M9120A
M9121A
M9122A
Channels
4x32
4x64
8x32
Switch type
2-wire,
armature
100 Vrms
2-wire, reed
100 Vrms
1-wire,
armature
100 Vrms
Max current
switch/carry
2.0 A
0.5 A
2.0 A
Max power (nom)
60 W
10 W
60 W
Max volts
(CAT 1)
Chassis slot compatibility: cPCI (J1), PXI-1, PXIe Hybrid
38
M9121A
M9122A
7.5 MHz
10 MHz
5 MHz
Connectors
78 Dsub
block/cable
200 LFH
block/ cable
50 Dsub
block/cable
Ordering Information
• Semiconductor
6
M9120A
Bandwidth (nom)
Model
Description
M9120A
PXI matrix switch: 4x32, 2-wire, 100 V/2 A armature
relays
M9121A
PXI matrix switch: 4x64, 2-wire, 100 V/0.5 A, reed
relays
M9122A
PXI matrix switch: 8x32, 1-wire, 100 V/2 A armature
relays
Related products
M9018A
18-slot PXIe chassis
M9021A
PCIe® cable interface
M9102A
128-ch, 1-wire multiplexer switch
M9131A
64-ch SPDT general purpose switch
M9187A
32-ch digital I/O
Accessories for M9120A
Y1181A
PXI connector block: 78-pin, shielded, female DSub
(recommended)
Y1187A
PXI connector cable: 78-pin, male-to-female, 1Meter
Y1188A
PXI connector cable: 78-pin, male-to-female, 2Meter
Accessories for M9121A
Y1182A
PXI connector block: 200-pin, shielded, male
Y1189A
PXI connector cable: 200-pin, LFH male to four 50 pin
Dtype female connectors, 1 meter
Y1190A
PXI connector cable: 200-pin, LFH male to four 50 pin
Dtype female connectors, 2 meter
Accessories for M9122A
Y1180A
PXI connector block: 50-pin female DSub
(recommended)
Y1185A
PXI connector cable: 50-pin, male-to-female, 1Meter
Y1186A
PXI connector cable: 50-pin, male-to-female, 2Meter
RF Switches
Agilent PXI
RF Switch Modules
www.agilent.com/find/pxi-switch
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations (c ont'd)
Switch
• Aerospace/defense, semiconductor, medical
Configuration
Insertion loss (typ) Isolation (typ)
RF 3 GHz, 75 Ω multiplexer switches
• Automotive
• Electronic test
P r o d u c t D e scr i p t i o n
The PXI RF switch modules deliver high-performance,
bi-directional switching up to 3GHz, and are available in
multiple configurations to integrate into a variety of test
environments. Modern RF relay technology delivers low
insertion loss and VSWR for excellent RF signal integrity
and dynamic range when routing RF signals into your
measurement equipment. Each switch path is carefully
designed to ensure repeatable RF performance.
M a i n F e a tur e s and B e ne fi t s
M9150A
Dual 1x4
1 dB
45 dB
M9151A
1x4
1.1 dB
40 dB
M9152A
1x8
1 dB
45 dB
M9153A
1x16
1.2 dB
40 dB
2 dB1
40 dB
RF 300 MHz, 50Ω matrix switch
M9128A
8x12
Ordering Information
Model
Description
M9128A
PXI RF matrix switch: 300 MHz, 8x12, 50 Ω
M9146A
PXI RF multiplexer: 3 GHz, dual 1x4, 50 Ω,
terminated
M9147A
PXI RF multiplexer: 3 GHz, quad 1x4, 50 Ω,
terminated common
M9148A
PXI RF multiplexer: 3 GHz, 1x8, 50 Ω
M9149A
PXI high-density RF multiplexer: 3 GHz, 1x16, 50 Ω
PXI RF multiplexer: 3 GHz, dual 1x4, 75 Ω
Product features
Your benefit
Modern RF relay technology delivers
low insertion loss and VSWR
Excellent RF signal integrity and
dynamic range
Each switch path carefully designed
Repeatable RF performance
M9150A
Software drivers support the
most common programming
environments
Work in your environment of
choice and reduce
development time
M9151A
PXI RF multiplexer: 3 GHz, quad 1x4, 75 Ω
M9152A
PXI high-density RF multiplexer: 3 GHz, 1x8, 75 Ω
Snap-on SMB connections, soft
front panels, Connection Expert
Fast and easy installation and
configuration
M9153A
PXI high-density RF multiplexer: 3 GHz, 1x16, 75 Ω
R e l at e d p rod uct s
S p e c i f i c a ti ons and C har act e r i st i cs
Switch
Configuration
Insertion loss (typ) Isolation (typ)
RF 3 GHz, 50 Ω multiplexer switches
M9018A
18-slot PXIe chassis
M9021A
PCIe® cable interface
M9045B
PCIe ExpressCard adaptor: Gen 1
Y1200B
PCIe cable: x1 to x8, 2.0m (used with M9045B)
M9048A
PCIe desktop PC adapter
PCIe cable: x8, 2.0m (used with M9048B)
M9146A
Dual 1x4
0.8 dB
45 dB
M9147A
Quad 1x4
1 dB
40 dB
Y1202A
M9148A
1x8
0.8 dB
40 dB
M9122A
8x32, 1-wire matrix switch
M9149A
1x16
1.2 dB
40 dB
M9103A
99-ch, 1-wire multiplexer switch
M9133A
100-ch SPST general purpose switch
M9187A
32-ch digital I/O
Chassis compatibility: cPCI (J1), PXI-1 (J1), PXIe Hybrid
6
39
GP Switches
Agilent General
Purpose Switch Modules
www.agilent.com/find/pxi-switch
P r o d u c t D e scr i p t i o n
Ordering Information
The PXI general purpose switch modules deliver fast,
reliable switching in a variety of configurations. Cycle
power to products under test, control indicator, and status
lights, or actuate external power relays and solenoids with
independent, single-pole, double-throw (Form C) or
singlepole, single-throw (Form A) switches in a single PXI
module. The line also includes a module that can handle
up to 300W/1250W for switching heavy loads or power
supplies.
6
Model
Description
M9130A
PXI SPDT switch: 26-ch, 2A, armature relays
M9131A
PXI SPDT switch: 64-ch, 100 Vrms/1A, reed relays
M9132A
PXI SPST switch: 50-ch, 100 Vrms/1A, reed relays
M9133A
PXI SPST switch: 100-ch, 100 Vrms/1A, reed relays
M9135A
PXI SPST power relay: 20-ch, 5A, 300 W
Related products
M9018A
18-slot PXIe chassis
M9021A
PCIe® cable interface
Your benefit
M9120A
4x32, 2-wire matrix switch
Up to 100-channel general
purpose EM relays
High-density, general
purpose switching in a
compact module
M9101A
64-ch, 2-wire multiplexer switch
M9187A
32-ch digital I/O
Power relay module
Get the performance you
need to switch heavy loads
with up to 300W (DC resistive
load)/1250W (AC resistive load)
Software drivers support the
most common programming
environments
Work in your environment of
choice and reduce development
time
Optional connector block, soft front
panels, and Connection Expert
Fast and easy installation and
configuration
Ma i n F e a tur e s and B e ne fi t s
Product features
S p e c i f i c a ti o ns and C har act e r i st i cs
Modules
Max volts
(CAT 1)
(typ)
Max switch/
carry rating
(typ)
Max
power
(nom)
M9130A 26-ch SPDT,
Form C, armature
250 Vrms
2A/2A
M9131A 64-ch SPDT,
Form C, reed
100 Vrms
M9132A 50-ch SPST,
Form A, reed
Accessories for M9130A
Y1181A
PXI connector block: 78-pin, shielded,
female DSub (recommended)
Y1187A
PXI connector cable: 78-pin, male-to-female, 1 Meter
Y1188A
PXI connector cable: 78-pin, male-to-female, 2 Meter
Accessories for M9131A, M9132A, M9133A
Y1182A
PXI connector block: 200-pin, shielded, male
(recommended)
Y1189A
PXI connector cable: 200-pin, male-to-female, 1 Meter
Y1190A
PXI connector cable: 200-pin, male-to-female, 2 Meter
Accessories for M9135A
Y1191A
PXI power cable: 20-pin, female-tounterminated, 1 Meter
60 W
Y1192A
PXI power cable: 20-pin, female-tounterminated, 2 Meter
0.25A/1A
3W
Y1193A
PXI power connector: 20-pin, female
(universal), solder pin (recommended)
100 Vrms
1A/1A
25 W
M9133A 100-ch
SPST, Form A, reed
100 Vrms
1A/1A
25 W
M9135A 20-ch SPST,
Form A, armature
250 Vrms/
125Vdc
5A/5A
300 W
40
Chassis compatibility: cPCI (J1), PXI-1 (J1), PXIe Hybrid
26.5 GHz Switches
Agilent M9155/6/7C
PXI Hybrid Switches
DC to 26.5 GHz
www.agilent.com/find/pxi-switch
I n d u s tr i e s and A p p l i cat i o ns
•
•
•
•
•
Automatic Test Equipment (ATE)
RF communications
Engineering verification
RF parametric measurements
Mid and high density switching systems
P r o d u c t D e scr i p t i o n
M9155/6/7C is a series of PXI hybrid switch modules
based on the PXI Hybrid platform. Operating from DC to
26.5 GHz, these modules come with guaranteed 0.03 dB
insertion loss repeatability throughout the operating life.
Spec ific ations
Hardware
Size
M9155C
M9156C
M9157C
Frequency
DC to 26.5 GHz
Insertion loss*
0.42 dB at 8 GHz
0.57 dB at 18 GHz
0.70 dB at 26.5 GHz
Insertion loss repeatability
< 0.03 dB
Guaranteed operating life
5 million cycles for M9155C
2 million cycles for M9155/6/7C
Typical operating life
10 million cycles for M9155C
5 million cycles for M9155/6/7C
VSWR*
1.35 at 8 GHz
1.45 at 18 GHz
1.70 at 26.5 GHz
Impedance
50 Ω
RF connector
3.5 mm (f) for M9155C
SMA (f) for M9156/7C
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefit
A readily scaled integrated
switching solution to satisfy your
unique application platform needs Peace of mind in switch
technology from Agilent who
has a proven track record for
providing versatile, quality RF
and microwave switches
1 slot wide
2 slots wide
3 slots wide
Ordering Information
Guaranteed 0.03 dB insertion
loss repeatability throughout the
operating life of up to 10 million
cycles
Reduce downtime for
recalibration, improve testing
efficiency and hence maximize
throughput
Model
Description
M9018A
PXIe Chassis, 18- slots, 3U, 8 GB/s
M9155C
PXIh Coaxial Switch, DC-26.5 GHz, Dual SPDT,
Unterminated
Unmatched isolation of
60 dB at 26.5 GHz
Maximize measurement
accuracy and system flexibility
M9156C
PXIh Coaxial Switch, DC to 26.5 GHz, Dual Transfer
M9157C
PXIh Coaxial Switch, DC to 26.5 GHz, Single SP6T,
Terminated
Soft front panel is available
for each switch module
The embedded graphical user
interface ease the trouble-shooting
of your PXI systems
Connector compatibility: PXI-H, PXI-1, cPCI
6
Related products
M9392A
PXI Vector Signal Analyzer
M9302A
PXI Local Oscillator
M9351A
PXI Downconverter (50 MHz to 2.9 GHz)
M9360A
PXI Attenuator/Preselector
M9361A
PXI Downconverter (2.75 GHz to 26.5 GHz)
41
40 GHz Switches
NEW
Agilent
M9155/6/7 CH40
PXI Hybrid Switch Modules
DC to 40 GHz
www.agilent.com/find/pxi-switch
I n d u s tr i e s and A p p l i cat i o ns
•
•
•
•
•
Automatic Test Equipment (ATE)
RF communications
Engineering verification
RF parametric measurements
Mid and high density switching systems
Spec ific ations
Hardware
Size
M9155CH40
M9156CH40
M9157CH40
Frequency
DC to 40 GHz
Insertion loss*
0.42 dB at 8 GHz
0.57 dB at 18 GHz
0.70 dB at 26.5 GHz
1.1 dB at 40 GHz
Insertion loss repeatability
< 0.03 dB
Guaranteed operating life
5 million cycles
Typical operating life
10 million cycles
Isolation* (M9157CH40)
100 dB at 12 GHz
70 dB at 20 GHz
65 dB at 40 GHz
VSWR*
1.35 at 8 GHz
1.45 at 18 GHz
1.70 at 26.5 GHz
1.95 at 40 GHz
Impedance
50 Ω
RF connector
2.92 mm (f) for M9155/6/7CH40
P r o d u c t D escr i p t i o n
6
M9155/6/7CH40 is a series of PXI hybrid switch modules
based on the PXI Hybrid platform. Operating from DC to 40
GHz, these modules come with guaranteed 0.03 dB insertion loss repeatability throughout the operating life.
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefit
A readily scaled integrated
switching solution to satisfy your
unique application platform needs Peace of mind in switch
technology from Agilent who
has a proven track record for
providing versatile, quality RF
and microwave switches
Guaranteed 0.03 dB insertion
loss repeatability throughout the
operating life of up to 10 million
cycles
Reduce downtime for
recalibration, improve testing
efficiency and hence maximize
throughput
Unmatched isolation of
60 dB at 26.5 GHz
Maximize measurement
accuracy and system flexibility
Soft front panel is available
for each switch module
The embedded graphical user
interface ease the trouble-shooting
of your PXI systems
Connector compatibility: PXI-H, PXI-1, cPCI
42
1 slot wide
2 slots wide
3 slots wide
Ordering Information
Model
Description
M9155CH40
PXIh Coaxial Switch, DC to 40 GHz,
Dual SPDT, Unterminated
M9156CH40
PXIh Coaxial Switch, DC to 40 GHz,
Dual Transfer
M9157CH40
PXIh Coaxial Switch, DC to 40 GHz,
Single SP6T Switch, Terminated
Related products
M9392A
PXI Vector Signal Analyzer
M9302A
PXI Local Oscillator
M9351A
PXI Downconverter (50 MHz to 2.9 GHz)
M9360A
PXI Attenuator/Preselector
M9361A
PXI Downconverter (2.75 GHz to 26.5 GHz)
M9170A
Agilent M9170A
PXI Attenuator/Switch Driver
www.agilent.com/find/pxidriver
I n d u s tr i e s and A p p l i cat i o ns
•
•
•
•
Automatic Test Equipment (ATE)
RF communications
Engineering verification
RF parametric measurements
P r o d u c t D e scr i p t i o n
M9170A attenuator/switch driver module provides drive
control for programmable attenuators and electromechanical switches. It is a PXI-hybrid compliant module, that
comes with a full-featured graphical interface soft front
panel (SFP) for easy control and trigger.
Ma i n F e a tur e s and B e ne fi t s
Product features
Your benefit
Drive up to 12 external SPDT
switches, or 4 external SP4T/6T
switches, or 12 transfer switches, or
2 external attenuators1
Maximize the PXI chassis slot
utilization, which ultimately
improves testing efficiency
Dual voltage supply of 5V and 24V,
and dual driving mode of pulse and
continuous
Ensure biasing compatibility
with most switches on the
market and hence increase
system flexibility
Soft front panel provides a dynamic
dashboard view and control of the
connected attenuators or switches
Allows the selection of device
models and the subsequent
switch paths or attenuation
levels
Point-to-point interface cable
options available for connection
between driver and switching device
Intuitive configuration for
all Agilent switches and
attenuators
1. The amount of switches and attenuators that can be driven is
dependent on the type of switch configuration and attenuator section
configuration.
Connector compatibility: cPCI, PXI-H, PXI-1
Spec ific ations and Charac teristic s
Hardware
Size
1 slot wide module
Voltage
+3.3V
+5V
-12V
+12V
Current
0.5A
30 mA(min)
5.6 A (max)
0
30 mA(min)
0.8 A(max)
Attenuator types
Accepts most attenuators available today
Switch types
Accepts most switches available today
6
Ordering Information
Model
Description
M9170A
PXI-h Attenuator/Switch Driver Module
Options
001
Interface cable, 20 pin to 10 pin DIP (x6) for transfer
switch
002
Interface cable, 20 pin to 10 pin DIP for step
attenuator
003
Interface cable, 20 pin to 12 pin Viking connector for
step attenuator
201
Interface cable, 20 pin to 16 pin bare wire for solder
lug switch
501
Interface cable, 20 pin to 9 pin DSUB (x6) for N1810x
SPDT switch
601
Interface cable, 20 pin to 16 pin DIP (x2) for 8710x/
L710x switch Related products
M9018A
18-slot PXIe chassis
87106C
Multiport Coaxial Switch, DC to 26.5 GHz, SP6T
8765C
Coaxial Switch, DC to 26.5 GHz, SPDT
8496G
Programmable Attenuator, 4 GHz, 110 dB, 10 dB steps
43
M9216A
Agilent M9216A
PXI 32-Channel High Voltage
Data Acquisition Module
www.agilent.com/find/m9216a
I n d u s tr i e s and A p p l i cat i o ns
Har d war e
•
Automotive
•
Electronic test
P r o d u c t D e scr i p t i o n
6
The M9216A is a high voltage data acquisition module that
allows simultaneous measurement of eight channels of positive
voltages ranging from 1 mV to 100 V. Each channel in the module
comes with concurrent 5 V and 100 V measurement ranges each channel capable of acquiring digital signals that fluctuate
between very low and very high voltage levels without switching
ranges and doing separate measurements.
The built-in 32 to eight multiplexer enables 32 measurement ports
to be connected to the eight acquisition channels expanding it to
a full 32-channel acquisition module. These channels can also be
routed via an auxiliary output connector for additional measurements without requiring extra multiplexers or pin matrix cards.
The fast parallel voltage level measurements with guaranteed
accuracy is ideal for the automotive applications. The16-bit ADC
utilizes positive voltages for enhanced resolution, and accuracy.
Ma i n F e a tur e s and B e ne fi t s
P ro d uct f eat ure s
Yo u r be n e f i t
Large input range
with dual concurrent
measurement range
for each channel
Enables voltage level acquisition to be
done for very low and very high voltages without the need for switching
ranges
Built-in 32 to 8
multiplexer
Expanding to 32-channel high speed
voltage acquisition capability
Auxiliary outputs
from the acquisition
channels
Enables additional measurements to
be done without requiring external
multiplexers and pin matrix cards
44
Spec ific ations
Size
2 slots, 3 U
Resolution
16 bit
Accuracy
Zero offset: 5 V range – 200 uV, 100 V range – 1 mV
Gain (% of reading): 5 V range – 0.05%, 100 V range – 0.05%
Noise @ 3 sigma: 5 V range – 200 uV, 100 V range – 2 mV
Ordering Information
Mod e l
D e s cri p t i on
M9216A
M9216A PXI high voltage data acquisition module, 32-channel, 250KS/S,
16-BIT, 100 V input
Chassis slot compatibility: cPCI(J1, J2), PXI-1, PXIe Hybrid
PXI Di gi t a l Inp ut O ut p u t
Product Features and your Benefits
Applications
• For monitoring digital states and controlling external devices
Functionality
• 32 input channels with programmable thresholds of 0.3 V to 50 V
• 32 output channels with 0.5 A low sink/0.4 A high source
Performance characteristics
• 100 V input protection
• Fully protected outputs
• High-quality D-Sub connectors
Agilent M9187A Digital IO
Agilent M9187A Digital IO
www.agilent.com/find/pxi-dio
P XI Digit al I n pu t O u t put
Agilent Technologies offers digital IO modules to meet your needs for digital sensing and control of simple devices
and digital functional testing. In the PXI modular format, Agilent offers a PXI digital IO for system monitoring and
controlling devices such as external relays.
M9187A
Agilent M9187A
PXI Digital I/O Control Module
www.agilent.com/find/pxi-dio
I n d u s tr i e s and A p p l i cat i o ns
• Aerospace/defense, semiconductor, electronic test
• Automotive, medical
Spec ific ations (c ont'd)
Output specifications
Max voltage (typ)
+50Vpk
Max current
0.5A for low-side drivers
0.4A for high-side drivers
10A module total
Output states
Driven high, driven low, or off
Low-side driver output voltage
0.3V @ Isink = 0.5A
High-side driver output voltage
Vext – 1.5V @ Isource = 0.4A
P r o d u c t D escr i p t i o n
7
The M9187A digital I/O control module has 32 input/output
channels. The input channels can be used for comparing
inputs to user-defined thresholds between 0.3V and 50V,
with 12.5mV setting resolution. Each input is protected up to
100V. The 32 output channels can drive high or low outputs,
and are capable of sourcing 0.4A from the high-side or sink
0.5A from the low-side of each channel. These outputs are
protected against over-voltage or over-current conditions.
Ma i n F e a tur e s and B e ne fi t s
Ordering Information
Model
Description
M9187A
PXI digital I/O: 32 input/output channels 0.3V to 50V
Related products
M9018A
18-slot PXIe chassis
Product features
Your benefit
M9021A
PCIe® cable interface
32 input/output channels
Provides the flexibility to meet
your testing needs
M9120A
4x32, 2-wire matrix switch
M9103A
99-ch, 1-wire multiplexer switch
M9135A
20-ch SPST general purpose switch
100V input protection and fully
protected outputs
Reliable performance
Software drivers support the
most common programming
environments
Work in your environment of
choice and reduce development
time
Optional connector block, soft front
panels, and Agilent Connection
Expert
Fast and easy installation and
configuration
S p e c i f i c a ti ons and C har act e r i st i c s
Input specifications
PXI connector block: 78-pin, shielded, female DSub
(recommended)
Y1187A
PXI connector cable: 78-pin, male-to-female, 1Meter
Y1188A
PXI connector cable: 78-pin, male-to- female, 2Meter
Softw are Information
+50Vpk, with 100Vpk over voltage
protection
Microsoft Windows XP
Microsoft Windows Vista (32/64-bit)
Microsoft Windows 7 (32/64-bit)
Standard compliant drivers
IVI-COM, IVI-C, LabVIEW, MATLAB
Dual programmable 0.3 to 50V,
12.5mV resolution
Supported application
development environments
(ADE)
VisualStudio (C/C++,C#, VB.NET),
LabVIEW, LabWindows/CVI, MATLAB,
VEE
Agilent IO Libraries
Includes: VISA Libraries, Agilent
Connection Expert, IO Monitor
1 MΩ
Max input voltage (typ)
Chassis slot compatibility: cPCI (J1), PXI-1, PXIe Hybrid
46
Y1181A
Operating systems
Input impedance
Thresholds
Accessories
PXI digi t a l M ULTIM ETERS
The M9181A delivers a low cost PXI DMM with basic features. This DMM measures common parameters such as DCV,
DCI, ACV, ACI, 2 and 4-wire resistance. The M9181A also offers 90 ppm basic DCV accuracy and inputs up to 240 V.
Agilent’s family of PXI digital multimeters deliver results you can trust.
Product features and your benefits
Applications
• DMM measurements in automated systems
• DMM measurements in functional test systems
Functionality
• DCV, DCI, ACV, ACI, 2- and 4-wire resistance
• Frequency/period, capacitance, temperature
• Advanced triggering
Performance characteristics
• 40 ppm basic DCV 1-yr accuracy
• Measurement speeds up to
15,000 rdgs/s
• 6½ digits of resolution (22 bits)
• Floating isolation (CATII) for
inputs up to 300 V
Agilent Digital Multimeters M9181A, M9182A and M9183A
www.agilent.com/find/pxi-dmm
P XI D igit al Mul t i m e ter s
Agilent Technologies M9182A and M9183A Digital Multimeters (DMM) deliver market-leading speed at their price points.
These fast reading speeds translate into higher test system throughput and lower cost of test. These DMM modules
measure common parameters such as DCV, DCI, ACV, ACI, 2- and 4-wire resistance as well as capacitance, temperature
and frequency. Each offers 40 ppm basic DCV accuracy and inputs up to 300 volts.
PXI d igi t a l m ul t im et e r s
P XI Digit al M u lt i m e ter s
Digital Multimeters
Description
Type
# of slots
Resolution
Maximum
reading rate at
4 1/2 digits
Basic DCV
accuracy &
maximum
range
Resistance,
temperature,
capacitance
Measurements and
functions
DC source
M9181A
Basic features
PXI DMM
PXI
1-slot
6½ digits
150 rdgs/sec
90 ppm
200 V
2 & 4-wire Ω
DCV, ACV, DCI, ACI
n/a
M9182A
High-performance
PXI DMM
PXI-H
1-slot
6½ digits
4,500 rdgs/sec
40 ppm
300 V
2 & 4-wire Ω,
temperature
capacitance
DCV, ACV, DCI, ACI,
plus frequency/period,
temperature,
and capacitance
n/a
M9183A
Enhanced
performance
PXI DMM
PXI-H
1-slot
6½ digits
15,000 rdgs/sec
40 ppm
300 V
2 & 4-wire Ω,
temperature
capacitance
All of the above plus
duty cycle,
counter/totalizer, DC
source
± 10 V
± (1.2 µA
to 12 mA)
Driver information
Supported operating systems
Microsoft Windows 7 (32/64-bit), Windows Vista (32/64-bit), Windows XP (32-bit)
Supported application development environments (ADE)
M9181A: Visual Studio (VB.NET, C#, C/C++), LabVIEW, LabWindows/CVI, MATLAB
M9182A & M9183A: Visual Studio (VB.NET, C#, C/C++), VEE, LabVIEW, LabWindows/
CVI, MATLAB
Application code examples
VB.NET, C#, C/C++
www.agilent.com/find/pxi-dmm
M9181A
Agilent M9181A
Basic Features PXI DMM
www.agilent.com/find/pxi-dmm
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations (c ont'd)
Sensitivity
• Aerospace and defense
• Automotive
• Electronic test
P r o d u c t D escr i p t i o n
The Agilent M9181A 6½ digit PXI digital multimeter (DMM)
offers the most common measurement functions at an
affordable price. The M9181A provides six built-in
measurement types with all the reliability and stability you
would expect from an Agilent PXI DMM.
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefits
Basic DCV accuracy of
90 ppm
Measurements you can trust
Measurements:
DCV, ACV, DCI, ACI
2- & 4-wire Ω
Basic digital multimeter
measurements for the most
common measurement
applications
Software drivers to support the
most common programming
environments
Work in your environment of
choice and reduce development
time
Soft front panel and Agilent
Connection Expert
Fast and easy installation,
configuration, and calibration
Specifications and Characteristics
Resolution
6½ digit
DCV basic 1-year accuracy
90 ppm
Maximum reading rate
(4½ digits)
Floating Isolation (CAT II)
150 rdgs/s
240 V
Measurement ranges
DCV, ACV; 4 ranges
DCI, ACI; 4 ranges
2- and 4-wire resistance; 6 ranges
Function
Lowest range
Sensitivity
DCV
200.0000 mV
100 nV
ACV
200.0000 mV
100 nV
Resistance
20.0000 Ω
100 µΩ
DCI
2.000000 mA
10 nA
ACI
2.000000 mA
1 nA
Resolution vs. aperture and reading rate for DCV, DCI, Ω
Measurement
aperture
Maximum readings per
second
Resolution
1.28 s
0.8
6½ Digits (21 bits)
160 ms
6
6 Digits (20 bits)
20 ms
45
5½ Digits (18 bits)
10 ms
85
5 Digits (17 bits)
5 ms
150
4½ Digits (16 bits)
8
Ordering Information
Model
Description
M9181A
PXI digital multimeter, 6½ digit, basic features
Accessories
34138A
Test lead set
Related Products
M9018A
18 slot PXI chassis
M9021A
PXIe system interface
M9101A
PXI high-density multiplexer, 64 ch, reed relays
M9120A
PXI matrix switch, 4 x 32, armature relays
M9182A
PXI multimeter, 6½ digit, high performance
M9183A
PXI multimeter, 6½ digit, enhanced performance
200 mV to 200 V
2 mA to 2 A
200 Ω to 20 MΩ
Chassis slot compatibility: PXI-1, (J-1)
49
M9182A/M9183A
Agilent
M9182A/M9183A
High-Performance PXI DMMs
www.agilent.com/find/pxi-dmm
P r o d u c t D escr i p t i o n
Spec ific ations (c ont'd)
Agilent’s M9182A and M9183A 6½ digit high-performance
PXI digital multimeters offer fast development, fast operation, and reliable results. The M9182A provides nine builtin measurement types with all the accuracy and stability
you would expect from an Agilent 6½ digital multimeter
(DMM). The M9183A provides the same capabilities as
the M9182A plus market-leading measurement speed,
additional ranges, and advanced triggering.
M a i n F e a tur e s and B e ne fi t s
8
M9182A
M9183A
Temperature
Thermocouple (B, E, J, K, N, R, S, T), RTD
(6 types), Thermistor (2.25 kΩ, 5 kΩ, 10 kΩ)
Other measurements
n/a
Offset compensated
ohms, pulse width &
duty cycle, totalizer/
event counter
DC Source
n/a
± 10 V, ± 12 mA
Floating isolation (Cat-II)
300 Vrms
300 Vrms
Function
Lowest Range
Sensitivity
DCV
200.0000 mV
0.1 µV
ACV
200.0000 mV
0.1 µV
Resistance (M9183A)
20.00000 Ω
10 µΩ
Resistance (M9182A)
200.0000 Ω
100 µΩ
Sensitivity
Product features
Your benefits
Measurement speeds up to 15,000
readings/second; single reading
interval time: 66 µs
Fast single reading test
throughput saves functional test
time, especially when taking
several different measurements
with the DMM
Basic DCV accuracy of 40 ppm
Measurements you can trust
DCI (M9183A)
200.0000 nA
0.1 pA
Measurements: DCV, ACV, DCI, ACI,
2 & 4-wire Ω, frequency/period,
temperature, capacitance
Reduces instrumentation and
accessories required
DCI (M9182A)
2.000000 mA
10 nA
ACI
2.000000 mA
1 nA
Software drivers support the
most common programming
environments
Work in your environment of
choice and reduce development
time
Capacitance
1000.0 pF
0.1 pF
Soft front panels and Agilent
connection expert
Fast and easy installation and
configuration
S p e c i f i c a ti o ns and C har act e r i st i c s
Resolution vs. aperture and reading rate for DCV, DCI, Ω
Measurement
aperture
Maximum
readings per sec
Resolution
10 ms
98
6½ digits (22 bits)
625 µs
1,200
5½ digits (18 bits)
4,500
4½ digits (14 bits)
15,000
4½ digits (14 bits)
Hardware
M9182A
M9183A
130 µs
Resolution
61/2 digit
61/2 digit
2.5 µs (M9183A only)
DCV basic 1-year
accuracy
40 ppm
40 ppm
41/2 digit rdg/s
4,500
15,000
Triggering
External, threshold level, pre- or post-
Measurement ranges
DCV, ACV
200 mV to 300 V
200 mV to 300 V
DCI
2 mA to 2 A
200 nA to 2 A
ACI
2 mA to 2 A
2 mA to 2 A
2 & 4-wire resistance
200 Ω to 20 MΩ
20 Ω to 200 MΩ
Frequency/period
1 Hz to 300 kHz
1 Hz to 300 kHz
Capacitance
1 nF to 10 mF
1 nF to 10 mF
50
Ordering Information
Model
Description
M9182A
PXI Digital Multimeter-6½ Digit
M9183A
PXI Digital Multimeter-6½ Digit, Enhanced
Performance
Accessories
34138A
Test Lead Set
Chassis slot compatibility: PXI-1, (J-1)
PXI Di gi t i zers
Agilent’s portfolio of PXI high-speed digitizers address test and measurement applications in industries as widespread as RF/uW, ultrasonics, biotechnology, semiconductors, aerospace and high energy physics. These digitizers
provide very high-speed measurements on wideband signals while maintaining high acquisition quality.
Product features and your benefits
Applications
• Aerospace & defense: Research and design validation in
radar, satellite and microwave communications.
• Wireless communications: Research, design validation and
test in emerging standards including 802.11ac, LTE-A.
• Wideband and high-resolution signal measurements
Functionality
• Large number of phase coherent channels
• On-board real-time signal processing
Agilent M9202A PXIe IF Digitizer.
• Long signal capture time and streaming
• Various scope-like features (programmable full scale ranges, offsets, impedance, triggering functions, etc)
• Segmented acquisition
Performance characteristics
• Up to 3 GHz instantaneous analog bandwidth and 4 GS/s
sampling rate
• > 80 dB dynamic range (i.e., 50 MHz wide signals)
• Up to 500 MB/s data transfer speed
Agilent MD1 soft front panel
High-speed digitizers are also available in other form
factors such AXIe, PCI, PCIe®, cPCI and VME.
For further information on these products, visit
www.agilent.com/find/embedded-digitizers
www.agilent.com/find/pxi-digitizers
P XI Digit izer s
Agilent offers modular digitizers in PXI-1, PXI-H and PXIe formats. Agilent's digitizers are analog-to-digital converter versatile cards based on a modular architecture enabling an easy integration in customer application systems.
PXI digi t i zers
P XI D igit ize rs
Digitizing Scopes¹
Description
Type
# of slots
Resolution
Number of
channels
Max. sample
rate
Bandwidth
Memory
depth
On-board
processing
M9210A
Digitizing scope
PXI-H
1-slot
10-bit
2
2 to 4 GS/s
1.4 GHz
512 MS
N/A
N2100B
10.3125
Gb/s digital
communication
analyzer
PXI-H
4-slots
12-bit
1 optical,
1 electrical
160 MS/s
12 GHz
(electrical),
7.5 GHz
(optical,
unfiltered)
1 MS
N/A
Type
# of slots
Resolution
Number of
channels
Max. sample
rate
Bandwidth
Memory
depth
On-board
processing
IF Digitizer¹
Description
M9202A
Digitizer
PXIe
1-slot
12-bit
1
2 GS/s
1 GHz
256 MS
DDC, Virtex-6
FPGA
M9211A
Digitizer
PXI-H
1-slot
10-bit
1
4 GS/s
3 GHz
512 MS
N/A
1. High-speed digitizers are also available in other form factors such PCI, PCIe®, cPCI and VME. For more information visit: www.agilent.com/find/embedded-digitizers.
Driver information
Supported operating systems
Microsoft Windows 7 (32/64-bit), Windows Vista (32/64-bit), Windows XP (32-bit)
Standard compliant drivers
IVI-COM, IVI-C, LabVIEW, MATLAB
Supported application development environments (ADE)
Visual Studio (VB.NET, C#, C/C++), VEE, LabVIEW, LabWindows/CVI, MATLAB
Agilent IO Libraries
Includes: VISA Libraries, Agilent Connection Expert, IO Monitor
Soft Fron t Panel
Agilent high-speed PXI digitizers include the Agilent MD1 soft front panel (SFP) graphical interface. This simple software application can
be used to control, verify the functionality and explore the capabilities of your high-speed digitizers. The MD1 SFP contains two main
windows, a control window and a display window. The control window may be set in either Oscilloscope mode or in Transient Recorder
mode, and contains functions that allow you to manipulate the acquisition parameters of the card. The top display window shows
the full acquisition, and the lower display window may be configured to show either a zoom on part of the waveform or the FFT of the
acquired data. The Agilent MD1 SFP also provides several different display settings and standard pre-configured measurements, like
standard deviation, peak-peak/RMS value, overshoot, etc.
www.agilent.com/find/pxi-digitizers
M9202A
Agilent M9202A
PXI Express 12-bit
Wideband IF Digitizer
www.agilent.com/find/m9202a
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations and Charac teristic s
Hardware
• Aerospace and defense
• Wireless communications
• Radar and wideband signal capture
P r o d u c t D escr i p t i o n
The M9202A PXIe Wideband IF Digitizer runs at 2 GS/s,
with up to 1 GHz instantaneous analog bandwidth and
offers DDR3 memory. Through firmware options and
the Xilinx Virtex-6 FPGA, the M9202A provides different
functionalities. The BAS option provides basic digitizer
functionality (signal capture, storing of data, transfer of
data, etc). The DDC option additionally offers real-time
digital down-conversion (DDC) algorithm in the 300 MHz to
700 MHz band, enabling improved analog performance and
reducing data upload time.
M a i n F e a tur e s and B e ne fi t s
Size
1 slot 3U
Resolution
12 bits
Sample rate
2 GS/s
Bandwidth
30 MHz (nominal) to 1 GHz
Streamed analog bandwidth
up to 50 MHz, or up to 100 MHz
Impedance
50 Ω (nominal)
Coupling
AC
Full scale (FS) range
+4 dBm (1 V pk-pk in 50 Ω)
Spurious-free dynamic range
(SFDR)
60 dBc (typical) in basic digitizer mode
84 dBc (typical) after digital downconversion (with DDC option)1
Effective number of bits
(ENOB)
9 bits (typical)
Sample clock sources
Internal (with internal or external
100 MHz ref) or external
Model
Description
M9202A
PXIe IF Digitizer: 12-bit, 1 GHz
M9202A-C01
Single channel
M9202A-F02
Frequency range: 2 GS/s
Standard memory: 512 MB
Product features
Your benefit
2 GS/s sampling rate
Fastest 12-bit PXIe Digitizer
M9202A-M05
Up to 1 GHz bandwidth
Able to capture wide bandwidth
signals
For complete list of available options, please see datasheet.
Related products
512 MB DDR3 memory
Large on-board memory
M9302A
PXI Local Oscillator: 3 GHz to 10 GHz
Real-time digital down-conversion
(DDC) algorithm
Data decimation, analog
performance improvement
M9351A
PXI Downconverter: 50 MHz to 2.9 GHz
On-board Xilinx Virtex-6 FPGA
On-board processing capability
M9361A
PXI Downconverter: 2.75 GHz to 26.5 GHz
Software support for easy
integration
Reduced development time
M9362A-D01
PXIe MW Quad Downconverter: 10 MHz to 26.5 GHz
M9360A
PXI Attenuator/Preselector: 100 kHz to 26.5 GHz
PXIe backplane
Fastest digitized data upload,
continuous data steaming
M9392A
PXI Vector Signal Analyzer
M9211A
PXI-H UWB IF Digitizer: 10-bit, 4 GS/s, 3 GHz
M9018A
18-slot PXIe Chassis
M9021A
PCIe® Cable Interface
89601B
89600 VSA software
Chassis slot compatibility: PXIe Hybrid, PXIe
9
Ordering Information
53
M9210A
Agilent M9210A
PXI-H 10-bit Digitizing Scope
www.agilent.com/find/m9210a
I n d u s tr i e s and A p p l i cat i o ns
• Aerospace/defense
Hardware
• Wireless communication
Size
1 slot 3U
Resolution
10 bits
Sample rate
10 MS/s to 2 GS/s (4 GS/s interleaving)
Bandwidth
50 Ω : DC to 1.5 GHz (typical)
1 MΩ: DC to 300 MHz (typical)
Impedance
Selectable 50 Ω/1 MΩ (nominal)
Coupling
Selectable AC/DC
Full scale (FS) range
0.05, 0.1, 0.2, 0.5, 1, 2, 5 V peak-peak in 50 Ω
0.5, 1, 2, 5, 10, 20, 50 V peak-peak in 1 MΩ
Offset range
± 2 V for ≤ 500 mV full scale ranges
50 Ω: ± 5 V for 1 to 5 V full scale ranges
1 MΩ: ± 20 V for 1 to 5 V full scale ranges
1 MΩ: ± 200 V for 10 to 50 V full scale ranges
DC accuracy
± 2.5% FS in 50 mV full scale range
± 2% FS in full scale ranges ≥ 100 mV
Effective Number Of
Bits (ENOB)
7.2 in 50 Ω (typical)
7.0 in 1 MΩ (typical)
• UWB applications (e.g. radar)
• Semiconductor testing
P r o d u c t D escr i p t i o n
9
Spec ific ations and Charac teristic s
The M9210A is a single-slot 3U PXI-Hybrid high-speed
Digitizing Scope featuring 2 channels with 1.4 GHz/300
MHz (50 Ω/1 MΩ input) analog bandwidth and up to 4
GS/s real-time sampling rate. The M9210A Digitizing
Scope comes with on-board memory of up to 512
MSamples. Making it the best alternative to the Agilent
VXI E1428.
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefit
10-bit resolution
Best accuracy measurements
Up to 2-4 GS/s real-time sampling
rate
Fastest digitizing scope
> 1.4 GHz bandwidth in 50 Ω
> 300 MHz bandwidth in 1 MΩ
Measure the fastest signals
Selectable 50 Ω/1 MΩ input
Scope-like input feature
256 MSamples/channel memory
Large on-board memory
Auto-synchronous bus system with
picoseconds-level accuracy
Multi-module synchronization
Software support for easy
integration
Reduced development time
Chassis slot compatibility: cPCI(J1/J2), PXI-1, PXIe Hybrid
54
Ordering Information
Model
Description
M9210A
PXI-H high-speed Digitizing Scope:
10-bit, 2-4 GS/s
M9210A-M06
Memory: 64 Msample acquisition
For complete list of available options, please see datasheet.
Related products
M9211A
PXI-H UWB IF Digitizer: 10-bit, 4 GS/s, 3 GHz
M9362A-D01
PXIe Microwave Quad Downconverter:
10 MHz to 26.5 GHz
M9018A
18-slot PXIe Chassis
M9021A
PCIe® Cable Interface
Accessories
U1093A-AS5
AS bus 2 connector
M9211A
Agilent M9211A
PXI-H 10-bit UWB IF Digitizer
www.agilent.com/find/m9211a
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations and Charac teristic s
• Aerospace and defense
Hardware
• Wireless communications
Size
1 slot 3U
Resolution
10 bits
Sample rate
10 MS/s to 4 GS/s
Bandwidth
> 3 GHz
Impedance
50 Ω (nominal)
Coupling
DC
Full scale (FS) range
+4 dBm (1 V pk-pk in 50 Ω)
Spurious-Free Dynamic
Range (SFDR)
53 dB
• Radar and wideband signal capture
P r o d u c t D e scr i p t i o n
The M9211A is a single-slot 3U PXI-Hybrid single-channel
ultra-wideband IF Digitizer able to capture signals of up to 3 GHz and running at up to 4 GS/s. The M9211A comes
with on-board memory of up to 512 MSamples.
Ordering Information
Ma i n F e a tur e s and B e ne fi t s
Product features
Your benefit
Up to 4 GS/s real-time
sampling rate
Fastest IF Digitizer
3 GHz analog bandwidth
Measure the fastest signals
512 MSamples memory
Large on-board memory
Auto-synchronous bus system with
picoseconds-level accuracy
Multi-module synchronization
Software support for easy
integration
Reduced development time
Chassis slot compatibility: cPCI(J1/J2), PXI-1, PXIe Hybrid
Model
Description
M9211A
PXI-H high-speed UWB IF Digitizer:
10-bit, 4 GS/s, 3 GHz
M9211A-M51
M51 Memory, 512 Msample acquisition
9
For complete list of available options, please see datasheet.
Related products
M9302A
PXI Local Oscillator: 3 GHz to 10 GHz
M9361A
PXI Downconverter: 2.75 GHz to 26.5 GHz
M9360A
PXI Attenuator/Preselector:
100 kHz to 26.5 GHz
M9202A
PXIe IF Digitizer: 12-bit, 1 GHz
M9210A
PXI-H Digitizing Scope: 10-bit, 2-4 GS/s
M9018A
18-slot PXIe Chassis
M9021A
PCIe® Cable Interface
Accessories
U1093A-AS5
AS bus 2 connector
55
PXI DIGITAL TO ANALOG CON V ERTERS
Equipped with the ability of supplying a wide range of voltage and current levels, the modules suit perfectly for
the automotive industry where high input voltage or current ranges comes as a very common requirement for
functional testing.
Product Features and your Benefits
• Supply high-voltage levels in parallel of up to 16 channels
• Large voltage current range
• SENSE input for guaranteed accuracy
• High-voltage device protection
Agilent M9185 PXI 8/16-Channel
Isolated D/A Converter
Agilent M9186 PXI Isolated Single
Channel Voltage/Current Source
PXI Interface
+
Control
of
FPGA
Isolator
DCOM GND
Interlock
INTRLCK
SENSE
AMP
R
Amplitude
DAC
OUTPUT
+
AMP
R1
R2
R3
R4
M9186A system connections with SENSE input
www.agilent.com/find/pxi-converters
P XI DI GI T AL T O AN A LO G CO N VE R TE RS
Agilent’s PXI digital to analog converters and V/I sources are capable of supplying high and low voltages levels as
well as source currents on one or multiple channels.
PXI d igi t a l t o a na l og c o n v e r t e r s
P XI DI GI T AL T O AN A LO G CO N VE R TE RS
Applications
• I/O pin parametric leakage
• Bias current
• Impedance
• Threshold and clamp voltage
V/I Source
Description
M9185A
D/A converter
M9186A
V/I source
Type
# of slots
PXI 2-slot (8 channel)
PXI 3-slot (16 channel)
PXI
2-slots
Channels/
crosspoints
Scan channel/
second
Max voltage
Max current
Frequency
range
8 or 16
channels
N/A
16 V
20 mA
N/A
1
N/A
100 V at 20 mA
16 V at 200 mA
200 mA
N/A
Driver information
Supported operating systems
Microsoft Windows 7 (32/64-bit), Windows Vista (32/64-bit), Windows XP (32-bit)
Included device drivers
IVI-COM, IVI-C, LabVIEW G
Included GUI
Soft front panel
www.agilent.com/find/pxi-converters
M9185A
Agilent M9185A
PXI 8/16-Channel
Isolated D/A Converter
www.agilent.com/find/m9185a
I n d u s tr i e s and A p p l i cat i o ns
•
Automotive
•
Electronic test
P r o d u c t D escr i p t i o n
The M9185A is a fully independent, isolated digital/analog
converter (D/A converter) that is capable of supplying high voltage
levels in parallel of up to eight or 16 channels. Each channel is
able to output up to 16 V as stimulus signals to device under
tests (DUTs). The M9185A also provides a built-in SENSE
mechanism, which detects output voltage levels and feeds the
information to the circuitry of the converter to compensate for
the voltage drop at the receiving end of a DUT. This feature
ensures the accuracy of the stimulus signals being provided to
the DUT for better test performance.
Spec ific ations
Har d war e
Size
2-slot for 8-channel, 3-slot for 16-channel,
3U
DC Voltage
Range: ±16 V up to 10 mA
Resolution: 16-bit = 500 µV
DC Current
Temperature
range
Accuracy:
± (0.05% + 3.0 mV)
Range: ±20 mA
Resolution:
16-bit = 630 nA
Accuracy: ± (0.09% + 5.0 µA)
Operating: 0° C to 55° C
Storage: –40° C to 70° C
Relative humidity 80%, 0° C to 40° C (non condensing)
Physical
characteristics
The M9185A is an ideal module for automotive applications where
signal accuracy is of high importance.
Dimensions:
8-channel, 2-slot: 40.30 mm x 128.40 mm x
215.00 mm (1.59 in x 5.06 in x 8.46 in)
16-channel, 3-slot: 60.50 mm x 128.40 mm x
215.00 mm (2.38 in x 5.06 in x 8.46 in)
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefit
High output
voltage levels
Provides higher voltage levels as
stimulus without the need for a pull up
circuit
Built-in SENSE
mechanism
Enables an auto feedback feature to the
DAC compensation circuitry for voltage
output adjustments to guarantee better
accuracy
Chassis slot compatibility: cPCI (J1, J2), PXI-1, PXIe Hybrid
Weight:8-channel: 0.47 kg (1.04 lb)
16-channel: 0.6 kg (1.32 lb)
Output connector: Stacked VHDCI
receptacle
Ordering Information
Mod e l
D e s cri p t i on
M9185A
M9185A PXI D/A converter, 8/16-channel,
16-bit, ±16 V
M9185A-001
8-channel configuration for M9185A
M9185A-002
16-channel configuration for M9185A
59
10
M9186A
Agilent M9186A
PXI Isolated Single Channel
Voltage/Current Source
www.agilent.com/find/m9186a
I n d u s tr i e s and A p p l i cat i o ns
•
Automotive
•
Electronic test
H ar dwar e
Size
Resolution
P r o d u c t D e scr i p t i o n
The M9186A two-slot, PXI based V/I source module enables the
sourcing of a voltage or current to perform measurements on the
resultant current or voltage through another module. It consists of
two separate amplifiers - one low voltage and one high voltage that share a common output connection. Both amplifiers can sense
the amount of current flowing while forcing a constant voltage.
A unique safety interlock feature automatically disables the highvoltage amplifier and opens all relays when the interlock circuit
is broken, providing protection to the device under test during the
presence of high voltages.
10 Ma i n F e a tur e s and B e ne fi t s
Product features
Large voltage-current
range 16 V at 200 mA to
100 V at 20 mA
SENSE input
Safety interlock
Your Benefit
Enables device under test
characterization required in
parametric testing of device
under test I/O pin
Enables accurate power source
supply to device under test
Protects the device under test from
damage due to high voltages
Chassis slot compatibility: cPCI (J1, J2), PXI-1, PXIe Hybrid
60
Spec ific ations and Charac teristic s
Accuracy
2 slots, 3 U
16 bit
±16 V up to 200 mA: 0.02 % + 3 mV
–10 to + 100 V at up to 20 mA: 0.02 % + 40
mV
Voltage Source Accuracy (% of output + offset)
16 V Range
Up to 200 mA:
0.02 % + 3 mV
Current Sense using the SENSE pin with
respect to OUTPUT:
200 mA range: 1.5 % + 500 μA
20 mA range: 0.5 % +50 μA
2 mA range: 0.5 % + 10 μA
200 μA range: 0.3 % + 5 μA
–10 to + 100 Range Up to 20 mA: 0.02 % + 20 mV
Current Sense using the SENSE pin with
respect to OUTPUT: 0.75 % + 300 μA
Current Source Accuracy (% of output + offset)
± 200 mA Range
± 20 mA Range
± 2 mA Range
± 200 μA Range
± 20 mA Range
0.3 % + 500 μA (Over ± 16 V)
0.1 % + 50 μA
0.3 % + 5 μA
0.1 % + 0.5 μA
0.2 % + 200 μA (Over –10 to +100 Vdc)
Ordering Information
Model
D esc r i pt i on
M9186A
M9186A PXI isolated single channel voltage/
current source, 100 V
Agilent’s modular arbitrary waveform generators deliver unprecedented performance for creation of complex
wideband waveforms. High sampling rate and high bit resolution provided in a single instrument enable designers
to create ideal waveforms for accurate test of radar, satellite and frequency agile systems. Providing up to 500 MHz
of modulation bandwidths and over 65 dBc of spurious free dynamic range, modular arbitrary waveform generators can be combined with a wideband I/Q upconverter to achieve modulation bandwidth of 1 GHz at microwave
frequencies for authentic signal simulations for IF and RF subsystem test.
Product Features and your Benefits
Applications
• High resolution with wide bandwidth
• DDS and Dynamic sequencing options
Functionality
• Very high signal quality arbitrary waveform generator
• Wide bandwidth
Performance characteristics
• 10- or 15-bit resolution
• 1.25 GS/s sampling rate for 500 MHz of bandwidth per
channel
• Advanced sequencing engine
Agilent M9331A Arbitrary Waveform
Generator 10-bit 1.25 GS/s
Agilent M9331A soft front panel
www.agilent.com/find/pxi-awg
P XI F un ctio n an d A rb i t ra ry Wa vefo r m G ene rat or s
PXI Fu nc t i on a nd A rb i t r a r y W a v e f o r m
Ge nera t ors
Fu nct io n a nd a rbi t ra r y w a v e f o r m ge n e r a t o r s
P XI Fun ctio n an d A rb i t ra ry Wa vef orm G ene rat or s
Function and Arbitrary Waveform Generators
Description
Type
# of slots
Resolution
Number of
channels
Bandwidth
per channel
Modulation
bandwidth
Sampling
rate
Memory depth
M9330A
Arbitrary
waveform
generator
PXI-H
4-slots
15-bit
2 ch
500 MHz
1 GHz
1.25 GS/s
16 MS
M9331A
Arbitrary
waveform
generator
PXI-H
4-slots
10-bit
2 ch
500 MHz
1 GHz
1.25 GS/s
16 MS
Driver information
Supported operating systems
Microsoft Windows 7 (32/64-bit), Windows Vista (32/64-bit), Windows XP (32-bit)
Standard compliant drivers
IVI-COM, IVI-C, LabVIEW, MATLAB
Supported application development environments (ADE)
Visual Studio (VB.NET, C#, C/C++), VEE, LabVIEW, LabWindows/CVI, MATLAB
Agilent IO Libraries
Includes: VISA Libraries, Agilent Connection Expert, IO Monitor
www.agilent.com/find/pxi-awg
M9330A
Agilent M9330A
PXI-H Arbitrary Waveform
Generator
www.agilent.com/find/m9330a
I n d u s tr i e s and A p p l i cat i o ns
• Aerospace Defense, wireless
Spec ific ations (c ont'd)
Impedance
50 Ω (nominal)
Output spectral purity
P r o d u c t D escr i p t i o n
Harmonic distortion
–65 dBc for DC to 500 MHz (nominal)
Non-harmonic spurious
–75 dBc for 1 kHz to 500 MHz (nominal)
Phase noise
The M9330A is a high resolution, wide-bandwidth arbitrary
waveform generator (AWG) capable of creating the most
realistic waveforms for radar, satellite, and frequency
agile communication systems, thanks to its 15-bit vertical
resolution and 1.25 GS/s sampling rate.
1 kHz: –95 dBc/Hz (nominal)
10 kHz: –115 dBc/Hz (nominal)
100 kHz: –138 dBc/Hz (nominal)
1 MHz: –150 dBc/Hz (nominal)
Noise floor
–150 dBc/Hz (nominal)
Sample clock
Internal or external
• Radar & satellite test
• Semiconductor testing
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefit
1.25 GS/s and 15 bits of vertical
resolution per channel
Provides exceptionally
realistic wideband waveforms
Dual output channels
Can generate the I and Q
components for wideband signal
modulation
Ordering Information
Model
Description
M9330A
PXI-H arbitrary waveform generator:
1.25 GS/s, 15-bit
M9330A-M08
Memory: 8 MS per channel
M9330A-125
Clock operation, 1.25 GS/s
M9330A-200
Arbitrary waveform generator software
11
Extended waveform memory and
advanced sequencing engine
Offers long scenario simulations
Multiple module synchronization
Provides multi-emitter
simulations
Related products
Multiple programmatic interfaces
Enable easy integration into
existing test environments
E8267D
PSG vector signal generator
M9331A
PXI-H Arbitrary Waveform Generator: 10-bit, 1.25 GS/s
M9392A
PXI Vector Signal Analyzer
M9202A
PXIe IF Digitizer: 12-bit, 2 GS/s, 1 GHz
M9018A
18-slot PXIe Chassis
M9021A
PCIe® Cable Interface
N7509A
Waveform Generation for Wideband Signal Simulation
N7620B
Signal Studio for Pulse Building
N7621B
Signal Studio for Multitone Distortion
S p e c i f i c a ti o ns and C har act e r i st i cs
Size
4 slots, 3U
Resolution
15 bits
Maximum sample rate
1.25 GS/s
Bandwidth
500 MHz per channel, 1 GHz modulated
(nominal)
Chassis slot compatibility: cPCI(J1/J2), PXI-1, PXIe Hybrid
For a complete list of available options, please see product brochure
Accessories
Y1176A
Kit to synchronize two M933XA series AWG
63
M9331A
Agilent M9331A
PXI-H Arbitrary Waveform
Generator
www.agilent.com/find/m9331a
I n d u s tr i e s and A p p l i cat i o ns
• Telecommunication
Bandwidth
• T&M ATE
500 MHz per channel, 1 GHz modulated
(nominal)
Impedance
50 Ω (nominal)
• Aerospace Defense T&M
Output spectral
purity
Harmonic distortion
–50 dBc for DC to 500 MHz (nominal)
Non-harmonic spurious
–75 dBc for 1 kHz to 500 MHz (nominal)
Phase noise
1 kHz: –95 dBc/Hz (nominal)
10 kHz: –115 dBc/Hz (nominal)
100 kHz: –138 dBc/Hz (nominal)
1 MHz: –150 dBc/Hz (nominal)
Noise floor
–150 dBc/Hz (nominal)
Sample clock
Internal or external
• Semiconductor testing
P r o d u c t D escr i p t i o n
The M9331A is a wide-bandwidth arbitrary waveform generator (AWG) capable of creating the ideal waveforms for
compliance testing of digital radios targeted for use with
communication standards such as MB-OFDM ultra wideband, 802.11n, MIMO, and proprietary wideband formats.
M a i n F e a tur e s and B e ne fi t s
11
Spec ific ations (c ont'd)
Product features
Your benefit
1.25 GS/s and 10 bits of vertical
resolution per channel
Provides wideband waveforms
with high signal quality
Dual output channels
Can generate the I and Q
components for wideband
signal modulation
Ordering Information
Model
Description
M9331A
PXI-H arbitrary waveform generator:
1.25 GS/s, 10-bit
M9331A-M08
Memory: 8 MS per channel
M9331A-125
Clock operation, 1.25 GS/s
Arbitrary waveform generator software
Extended memory and advanced
sequencing engine
Allows for extended simulations
of complex waveform
propagation models
M9331A-200
Multiple module synchronization
Provides multi-emitter
simulations suitable for MIMO
applications
Related products
Multiple programmatic interfaces
Enable easy integration into
existing test environments
S p e c i f i c a ti o ns and C har act e r i st i cs
For a complete list of options, please see product brochure
E8267D
PSG vector signal generator
M9330A
PXI-H Arbitrary Waveform Generator: 15-bit, 1.25 GS/s
M9392A
PXI Vector Signal Analyzer
M9202A
PXIe IF Digitizer: 12-bit, 2 GS/s, 1 GHz
M9018A
18-slot PXIe Chassis
Size
4 slots, 3U
M9021A
PCIe® Cable Interface
Resolution
10 bits
Maximum sample
rate
1.25 GS/s
N7509A
Waveform Generation for Wideband Signal Simulation
N7620B
Signal Studio for Pulse Building
N7621B
Signal Studio for Multitone Distortion
Y1176A
Kit to synchronize two M933XA series AWG
Chassis slot compatibility: cPCI(J1/J2), PXI-1, PXIe Hybrid
64
PXI LOGIC ANALYSIS AND P ROTOCOL TEST
Product features
• For RFIC test, simulates a BB-IC
• RFIC prototype turn-on and characterization
• RFIC integration and troubleshooting
• Automated test
• Gear2 and multi-lane support
• Real-time DigRF stimulus and analysis
• Bit level to modulation level measurements for RF and
digital design teams
Software
Agilent M9252A DigRF Host Adapter
The Agilent M9252A supports configurable traffic generation with customizable headers, payloads, and framesequence control. The host adapter allows the user to characterize and analyze RFIC performance with LTEAdvanced transmit and receive waveforms.
• Automatic support of ARQ in hardware
• Precise control of timing for each DigRF frame sent
• Inject a group of DigRF frames under software (API) control
while transmission is active
• Control ‘clustering’ of multiple DLCs
• Create valid GSM symbols over the TX sublink
• Supports multiple (2) independent DLC channels
• Convert IQ data to DigRF from a variety of input formats such as ASCII files, Signal Studio, SystemVue and ADS.
Internal 128 MB data memory is used as transmit source
• Automatically extract the IQ data from the DigRF data stream in hardware. The data is written into the internal
256-MB DDR memory. The data can be evaluated using the 89600 VSA software
• Programmable IQ resolution per DLC and number of IQ samples in a DigRF frame per DLC
• Selectable sample rate per DLC on TX and RX sublink
• IQ samples and resolution automatic selection based on air-standard
Driver information
Supported operating systems
Standard compliant drivers
Microsoft Windows XP (32-bit)
Microsoft Windows 7 (32/64-bit)
IVI-COM, IVI-C, LabVIEW
www.agilent.com/find/m9252a
P XI LOG I C ANAL Y SI S A ND PRO TO CO L T EST
For designers and integrators of RFIC and BBIC chipsets using DigRF v4, Agilent´s PXI protocol test solution
enables comprehensive stimulus and analysis capabilities in the digital and RF domains as well as across domains.
See the RDX solution to enable RF physical domain stimulus and analysis across an RFIC chip. Our tools provide
the fastest insight into the performance of your mobile handset design from turn on through to integration and
verification.
NEW
Agilent M9252A
DigRF Host Adapter
www.agilent.com/find/m9252a
I n d u s tr i e s and A p p l i cat i o ns
DigRF is used in mobile terminals for Long Term Evolution
(LTE) and WiMAX™ communications, including:
• RFIC development test
• RFIC validation
P r o d u c t D e scr i p t i o n
The M9252A DigRF Host Adapter, part the Agilent RDX
family, provides the serial stimulus capabilities required
for the MIPITM Alliance DigRF v4-based RFIC evaluation
and characterization. A single module combines stimulus
and Rx side capture capabilities to generate configurable
control and data traffic and observe the response from the
Device Under Test (DUT). It allows engineers to work in the
domain (digital or RF) of their choice to quickly characterize the DUT’s digital and wireless behavior.
Ma i n F e a tur e s and B e ne fi t s
Product features
Your benefit
Gear 2 (HS2x) support
Test high throughput to the latest MIPI
specifications
Multi-link
Support for 1Rx/1Tx at low power or
4Rx/2Tx at Gear 2 high speed
Complete programmatic control
for complete production testing
requirements
Immediate access to the industry’s
broadest, most advanced standardsbased demodulation and signal analysis
For RFIC test, simulates a
BB-IC
Automation API
Seamless integration with
Agilent 89600 VSA software
Hardware
Size
DigRF v4
DUT connection
GPIO bus
Trigger Input/Output
• RFIC device integration
12
Spec ific ations and Charac teristic s
Control and configure the RFIC to match
the test setup
Link speeds
Link support
Lane configurations
66
Low power (LP)
High speed (HS1x) Gear 1
High speed (HS2x) Gear 2 (Option 001)
1 link
2 links (Option 002)
Primary and secondary lanes
1Tx/1Rx
1Tx/2Rx
2Tx/4Rx (Option 003)
Ordering Information
Model
M9252A
M9252A-001
M9252A-002
M9252A-003
Interface cable
Description
PXIe DigRF host adapter
Enable Gear 2 (HS2x)
Enable secondary link
Link extension (2Tx/4Rx lanes)
(cannot be used with Option 002)
M9255A
DUT connection cable Samtec 50-pin
ERF8-025-05.0-L-DV
M9256A
DigRF interface converter for M9255A to SMA
connectors
Upgrades
M9252AU-001
M9252AU-002
M9252AU-003
M9252A-112
M9252AU-112
Chassis slot compatibility: PXIe, PXIe Hybrid
1 slot 3U
Version 1.0 and 1.1
Samtec 50-pin ERF8-025-05.0-L-DV
A 6-pin-width GPIO bus can stimulate and
sense proprietary interfaces
MMCX connections for external device
synchronization
M9252AU-124
G2 speed enhancement license
Upgrade to 2 links (2Rx/1Tx each)
Link upgrade to 4Rx/2Tx license
Twelve month core software update subscription
service (Standard)
Twelve month M9252A core software update
subscription renewal
Twenty-four month core software update
subscription service renewal
PXIe Op ti c a l E x t ender s f o r I n s t r u m e n t s
Product family
M9403ARF to Optical Converter
M9404AOptical to RF Receiver
M9404A30dB RF Amplifier
M9406AUSB Optical to USB 2.0
M9407AOptical to 4 port USB 2.0 Hub
M9408ADual Reflectometer
Product features and your benefits
Typical link conversion loss using the Agilent
M9403A optical transmitter and M9404A optical
receiver without an amplifier.
Applications
• Antenna ranges
• Network analyzer port extender
• Isolated measurements
Performance characteristics
• 300 kHz to 26.5 or 50 GHz
• 5 dB of loss @ 13 GHz with preamp
• Achieve transmission lengths up to and beyond 1 Kilometer
• Full PNA port extension
Typical link performance using the Agilent M9403A
optical transmitter and M940A4 optical receiver with
the M9405A amplifier.
Agilent M9403A PXIe Optical Transmitter, M9404A PXIe Optical Receiver, M9405A PXIe
Amplifier, M9406A PXIe Optical to USB 2.0, M9407A PXIe Optical to 4 Port USB 2.0 Hub and
M9408A PXIe Remote RF Reflectometer.
www.agilent.com/find/pxi-opticalextenders
P XI e O pt ical E xt en de rs fo r In s t rume nts
Agilent’s Optical Extenders for Instruments can transmit your RF or Microwave signal without the power loss of
coaxial cables and undesired mixing products of downconversion techniques—and with the isolation of fiber for
extended distances up to and beyond 1000 meters. Adaptable to a broad range of applications requiring long RF
transmission paths, the modules are configurable to meet the requirements of your application.
OPTICAL EXTENDERS
Agilent PXIe
Optical Extenders for Instruments
www.agilent.com/find/pxi-opticalextenders
I n d u s tr i e s and A p p l i cat i o ns
• Antenna ranges, remote antennas, earth stations
M9406A USB Optical
• Network analyzer port extenders
Data Rate
1.5, (USB 1.0), 12, (USB 1.1) and 480 (USB 2.0) Mbps
• Isolated measurements
Optical Link RF Performance (M9403A, M9404A) (nominal)
Input Power
Unamplified (Opt H01)
P r o d u c t D escr i p t i o n
Min RF Input
Level
-120 dBm (based on PNA-X noise floor measurements)
Max Optimum
RF Input Level
7 dBm
Return Loss
300 kHz to 26.5 GHz (Opt F26) 300 kHz to 50 GHz (Opt F50)
RF Source
Return Loss
> 10 dB
> 6 dB
RF Receiver
Return Loss
> 8 dB
> 8 dB
Agilent’s Optical eXtenders for Instruments can deliver
your RF or Microwave signal without the power loss of
coaxial cables, without the unwanted mixing products of
downconversion techniques, and with the isolation of fiber
at distances up to and beyond 1000 meters. Choose the
combination of modules that best fits your requirements
today with the confidence that you can scale the solution
to meet the requirements of tomorrow by taking advantage
of the modularity, scalability and upgradability of PXI.
M a i n F e a tur e s and B e ne fi t s
13
Charac teristic (nominal) c ont'd
Product features
Your benefit
Minimal insertion loss
Transmit your signal over long
distances and make measurements of
large devices
Operate from 300 kHz to 26.5
or 50 GHz
Amplified (Opt H02)
-25 dBm
Ordering Information
Model
Description
Local Chassis
M9403A
Optical Transmitter, Unamplified (H01)
300 kHz to 26.5 GHz (F26) or 50 GHz (F50)
Eliminate the need for expensive down
conversion equipment
M9406A
USB to Optical
Remote systems without
the need for a controller or
software development
Install your cards, connect your cables
and power up. It’s that simple.
M9404A
Optical Receiver, with Unamplified (H01)
300 kHz to 26.5 GHz (F26) or 50 GHz (F50)
Flexible system
configurations
Select the combination of modules
that meets your requirements
M9407A
Optical to 4 Port USB 2.0 Hub
Ability to add USB keyboard,
mouse, power sensor, e-Cal
and USB-to-VGA converter
Full remote control
Ch a r a c te r i st i c P e r fo r m ance ( no m inal)
Frequency Range
Option F26: 300 kHz to 26.5 GHz
Option F50: 300 kHz to 50 GHz
Spurious Free
Dynamic Range
> 90 dB/Hz
> 110 dB/Hz
Noise Figure:
Opt H01 (unamp): 26.5 GHz, 34 dB, 50 GHz, 42 dB
Opt H02 (amp): 26.5 GHz, 8 dB, 50 GHz, 12 dB
Link Gain
Option H01: > -30 dB
Option H02: > -4 dB
68
Remote Chassis
Related products
N5242A
PNA-X Network Analyzer, 26.5 GHz
N5245A
PNA-X Network Analyzer, 50 GHz
M9155C
PXI Hybrid Dual SPDT Coaxial Switch, 26.5 GHz
U2002A
USB Power Sensor, 50 MHz to 24 GHz, 3.5mm
N4691B
Electronic Calibration Module, 26.5 GHz, 2-port
M9018A
18-slot PXIe Chassis
Chassis slot compatibility: PXIe, PXIe Hybrid
PXI signa l A na l y zers a n d Si gn a l c o n d i t i o n i n g
RF requirements keep growing while timelines keep shrinking. To help ease the technical and business pressures, the right
test solution provides continuity in measurements and longevity in capability. The new M9391A PXIe RF Vector Signal
Analyzer (PXI VSA) is the next logical step in RF signal analysis. The PXI VSA combined with the M9381A PXIe RF Vector
Signal Generator - the new VSA/G - provides fast and high quality measurements optimized for RF manufacturing test environments. Agilent's broad portfolio of software applications enable use of the same measurement algorithms from design
to manufacturing.
NEW
Product features and your benefits
• The M9391A PXIe RF Vector Signal Analyzer for frequencies
from 1 MHz to 6 GHz works seamlessly with the M9381A
PXIe RF Vector Signal Generator for fast, high quality RF
measurements. To help you get proven results even faster,
Agilent's X-Series Measurement Applications for Modular
Instruments, 89600 VSA and SystemVue software enable
you to investigate, validate and test your RF communications
designs.
• The M9392A PXI Microwave Vector Signal Analyzer
Agilent M9391A PXIe RF Vector Signal Analyzer
combined with the Agilent 89600 VSA software, delivers a
complete microwave vector signal analyzer solution enabling analysis of signals from 50 MHz to 26.5 GHz with 250 MHz
of instantaneous bandwidth.
• The Dual Channel PXI Vector Signal Analyzer configuration,
based on two M9392A PXI vector signal analyzers, delivers
simultaneous, independently tuned, wide bandwidth analysis
of two RF/uW signals. Typical applications include gapless
recording over long durations and multichannel streaming.
• The Wideband MIMO PXI Vector Signal Analyzer configuration
delivers simultaneous bandwidth analysis up to 800 MHz on
four channels. For engineers working on 802.11ac applications,
this PXI configuration provides analysis capabilities for up to
4x4 MIMO and is ideal for 80 + 80 MHz SISO and 80 MHz or
160 MHz MIMO 802.11ac measurements.
Agilent M9073A X-Series Measurement Application for
W-CDMA/HSPA+
Agilent Dual Channel PXI Vector Signal Analyzer
Agilent Wideband MIMO PXI Vector Signal Analyzer
www.agilent.com/find/pxi-vsa
P XI sig na l A na lyze r s a n d S i gn a l co nditio ning
Be ready for tomorrow - today
PXI Si gn a l A na l y zers a n d Si gn a l c o n d i t i o n i n g
P XI Sig na l A na lyze r s a n d S i gn a l co nditio ning
Achieve continuity in measurements
Agilent's broad portfolio of world-class software applications accelerate your project's design to manufacturing cycle.
From model-based system level design validation, to detailed measurement data analysis of complex devices to RF standard conformance measurements, Agilent provides ways to achieve more confidence and continuity in measurements from
R&D to manufacturing.
Software application features and your benefits
• SystemVue system-level design automation software enables you to create model-based design validation from design
concept to hardware manufacturing. SystemVue can be used with the M9391A PXI VSA.
• Accelerate development with a consistent set of tools using the 89600 VSA software to characterize complex signals
in the time, frequency and modulation domains. The 89600 VSA software ensures comparable measurement results
across all stages of design with support for more than 40 Agilent hardware platforms.
• The X-Series measurement applications for modular instruments transforms the M9391A PXI VSA into standards
based RF transmitter testers. They provide fast RF conformance measurements to help quickly test components and
devices in high volume manufacturing.
X-Series measurement applications for modular instruments, pictured with
the Agilent M9391A and M9381A PXI VSA/G.
Software Applications for PXI Vector Signal Analyzers
Model
Description
Modular Instruments Supported
89601B
89600 VSA software
M9391A PXIe RF Vector Signal Analyzer
M9392A PXI Microwave Vector Signal Analyzer
M9071A M9082A
X-Series Measurement Applications for
Modular Instruments
M9391A PXIe RF Vector Signal Analyzer
W1461BP
SystemVue
M9381A PXIe Vector Signal Generator
M9391A PXIe Vector Signal Analyzer
www.agilent.com/find/pxi-vsa
PXI Si gna l A na l y zers a n d Si gn a l c o n d i t i o n i n g
Description
Type
# of slots
Frequency
range
Phase noise
(10 kHz offset)
DANL at 1
GHz
3rd order intercept
(TOI) at 1 GHz
Analysis
bandwidth
Software
applications
40 MHz
100 MHz or
160 MHz
X-Series
Meas App
SystemVue
89600 VSA
M9391A
PXIe RF Vector
Signal Analyzer
PXI
PXIe
4-slot
1 MHz to
6 GHz
< -120 dBc/Hz
(at 1 GHz, 20
kHz offset)
M9392A
PXIe MW
Vector Signal
Analyzer
PXI
PXIe
8-slot
50 MHz to
26.5 GHz
-115 dBc/Hz
(at 10 GHz)
nominal
-158 dBm/Hz
nominal
-10 dBm
(two -40 dB tones,
1 MHz apart)
250 MHz
(≥ 2.75 GHz)
89600 VSA
M9302A
Local Oscillator
PXI
2-slot
3 GHz to
10 GHz
-115 dBc/Hz
(at 10 GHz)
nominal
N/A
N/A
N/A
N/A
M9351A
Downconverter
PXI
1-slot
50 MHz to
2.9 GHz
N/A
N/A
-10 dBm
(two -40 dB tones,
1 MHz apart)
40 MHz
N/A
M9360A
Attenuator/
Preselector
PXI
3-slot
100 KHz to
26.5 GHz
N/A
N/A
N/A
40 MHz min
(3 dB BW,
YIG-tuned
filter YTF)
N/A
M9361A
Downconverter
PXI
1-slot
2.75 GHz to
26.5 GHz
N/A
N/A
-10 dBm
(two -40 dB tones,
1 MHz apart)
250 MHz
N/A
M9202A
IF Digitizer
PXIe
1-slot
2 GS/s
(sampling rate)
N/A
-144 dBm/
Hz (noise
density)
N/A
30 MHz to
1 GHz
N/A
M9362A-D01
Quad
Downconverter
PXI
3-slot
10 MHz to
26.5 GHz
N/A
N/A
N/A
1.5 GHz/
Channel
N/A
Signal Conditioning Modules
Description
Type
# of slots
Frequency
range
Bandwidth
Noise figure
TOI
IF center
frequency
Min/max
power
M9168C
Attenuator
PXI
2-slot
DC to 26.5
GHz
DC to 26.5 GHz
N/A
N/A
N/A
+30 dBm
(max)
M9351A
Downconverter
PXI
1-slot
50 MHz to
2.9 GHz
40 MHz
10 dB max
-10 dBm
(two -40 dB
tones,
1 MHz apart)
500 MHz
-160 dBm/
-30 dBm
M9352A
PXI Hybrid
Amplifier/
Attenuator
PXI
1-slot
10 MHz to 1
GHz
Analog
Bandwidth (3dB)
1 GHz
3 dB
+43 dBm
n/a
n/a
M9361A
Downconverter
PXI
1-slot
2.75 GHz to
26.5 GHz
250 MHz
30 dB at
26.5 GHz
-10 dBm
(two -40 dB
tones,
1 MHz apart)
500 MHz
-30 dBm (max)
M9360A
Attenuator/
Preselector
PXI
3-slot
100 kHz to
26.5 GHz
35 MHz to
120 MHz
(3 dB BW, YTF)
N/A
N/A
N/A
+30 dBm
(max)
M9362A-D01
Quad
Downconverter
PXI
3-slot
10 MHz to
26.5 GHz
1.5 GHz
N/A
N/A
N/A
N/A
Driver information
Supported operating systems
Microsoft Windows 7 (32/64-bit), Windows Vista (32/64-bit), Windows XP (32-bit)
M9168C does not support Windows Vista
Standard compliant drivers
IVI-COM, IVI-C, LabVIEW, MATLAB
Supported application development environments (ADE)
Visual Studio (VB.NET, C#, C/C++), VEE, LabVIEW, LabWindows/CVI, MATLAB
Agilent IO Libraries
All except M9168C: VISA Libraries, Agilent Connection Expert, IO Monitor
www.agilent.com/find/pxi-vsa
P XI sig na l A na lyze r s a n d S i gn a l co nditio ning
Spectrum and Signal Analyzers
X-SERIES MEASUREMENT APPLICATIONS
NEW
Agilent X-Series
Measurement Applications for
Modular Instruments
www.agilent.com/find/pxi-x-series_apps
I n d u s tr i e s and A p p l i cat i o ns
Resourc e M anager
• LTE-FDD, LTE-TDD
Agilent's X-Series measurement applications for modular
instruments include a unique resource manager that
provides direct access to PXI VSA hardware drivers for the
fastest power and spectrum-based measurements while
simultaneously using fast modulation quality measurements provided in the X-Series measurement applications.
Time spent switching between different applications is also
significantly faster, thanks to the resource manager.
• WCDMA/TD-SCDMA/HSPA, HSPA+
• GSM/EDGE/EVO
• 1xEV-DO, cdma2000®/cdmaOne
• WLAN 802.11a/b/g/n/ac
P r o d u c t D e scr i p t i o n
Eight of Agilent's popular X-Series measurement applications
- the same applications used with the X-Series signal analyzers - expand the capabilities of the M9391A PXIe Vector
Signal Analyzer (PXI VSA). Combining these applications
with the raw hardware speed of the PXI VSA enables faster
measurements and lowers the cost of test, while ensuring
measurement continuity from design to manufacturing.
X-Series measurement applications for modular instruments transform PXI VSAs into standards based RF transmitter testers. They provide fast RF conformance measurements to help quickly test components and devices in high
volume manufacturing.
14
72
Ma i n F e a tur e s and B e ne fi t s
Product features
Your benefit
Shared SCPI programming
commands
Minimizes effort and cost of
creating new test systems.
Unique resource manager
in X-Series measurement
applications for modular
instruments
Provides fast switching between
raw data measurements and
standards based measurements.
Proven measurement algorithms
and results
Consistent test results from
design to manufacturing
Standards-based measurements
Confidence that tests meet
required standards
Transportable license
Supports up to four PXI VSA
measurement channels in one PXI
chassis.
Ordering Information
Model
Description
M9071A
GSM/EDGE/EVO Measurement Application
M9072A
cdma2000/cdmaOne Measurement Application
M9073A
W-CDMA/HSPA+ Measurement Application
M9076A
1xEV-DO Measurement Application
M9077A
WLAN 802.11a/b/g/n/ac Measurement
Application
M9079A
TD-SCDMA/HSPA Measurement Application
M9080A
LTE FDD Measurement Application
M9082A
LTE TDD Measurement Application
Softw are Information
Software operating
systems
Microsoft Windows XP (32-bit)
Microsoft Windows 7 (32/64-bit) Microsoft
Windows Vista SP1 and SP2 (32/64-bit)
3rd party applications
and development
environment integrated
with X-Series Apps
VisualStudio (C/C++, C#, VB.NET), LabVIEW,
LabWindows/CVI, MATLAB, VEE
89600 VSA SOFTWARE
Agilent
89600 VSA Software
www.agilent.com/find/89600
I n d u s tr i e s and A p p l i cat i o ns
• Cellular communications
Ordering Information
Model
Description
89601B
89600 VSA software, transportable license
89601B-200
Basic vector signal analysis
89601B-300
Hardware connectivity
89601B-AYA
Vector modulation analysis
89601B-B7T
cdma2000®/1xEV-DO
Development becomes more complex when faster data
rates intersect with today’s crowded spectral environment.
Finding a signal problem is essential --but achieving the
clarity to pinpoint the answer is the crucial challenge. The
89600 VSA software is a comprehensive set of tools for demodulation and vector signal analysis. These tools enable
you to explore virtually every facet of a signal and optimize
your most advanced designs. As you assess the tradeoffs,
the 89600 VSA helps you see through the complexity.
89601B-B7U
W-CDMA/HSPA+
89601B-B7R
WLAN 802.11a/b/g
89601B-B7Z
WLAN 802.11n
89601B-BHJ
WLAN 802.11ac
89601B-B7X
TD-SCDMA/HSPDA GSM/EDGE/Evo
89601B-BHD
LTE FDD
89601B-BHG
LTE - Advanced FDD
89601B-BHE
LTE TDD
89601B-BHH
LTE - Advanced TDD
Ma i n F e a tur e s and B e ne fi t s
89601B-BHF
Custom OFDM
89601B-BHC
RFID
• Wireless connectivity
• Aerospace/defense
P r o d u c t D e scr i p t i o n
Product features
Your benefits
Supports more than 75 signal
standards and modulation types.
Measure your signal
Multiple simultaneous views in
time, frequency and modulation
domains.
View signal performance quickly.
Consistent measurement science
from baseband to RF.
Accelerate development with
consistent measurements across
broad frequency range from R&D
to manufacturing.
Softw are Information
Software operating
systems
Microsoft Windows XP (32-bit)
Microsoft Windows 7 (32/64-bit) Microsoft
Windows Vista SP1 and SP2 (32/64-bit)
Agilent software
applications that are
tightly integrated with
SystemVue
Agilent test software: I/O Libraries,
Command Expert
Agilent EDA software: Advanced Design
System, SystemVue
3rd party applications
and development
environments
integrated with 89600
VSA software
VisualStudio (C/C++, C#, VB.NET), LabVIEW,
LabWindows/CVI, MATLAB, VEE
14
73
SYSTEMVUE
Agilent SystemVue
System Level Design & Verification
www.agilent.com/find/systemvue
T y p i c a l A p p l i cat i o ns
• Signal generation with fading & impairments
• Early standards support
• Wideband system validation
P r o d u c t D escr i p t i o n
Agilent SystemVue is a system-level EDA environment
that accelerates design and verification of defense and
communications systems at the physical layer, where
advanced digital signal processing meets RF. SystemVue
brings together baseband algorithm modeling, accurate
RF, trusted Reference IP, and measurement automation
in a single environment for high-performance RF/DSP
co-design.
Agilent SystemVue combines with Agilent Modular
Products to create an expandable platform for modeling,
implementing, and validating next-generation communications systems and defense systems. A modular approach
enables a virtual system to be verified from the first day of
the project - beginning with simulation models and incorporating measurements as the project progresses.
Ordering Information
Recommended Products & Environments
Core Environment
• W1461BP SystemVue Comms Architect
People who use Agilent Modular Instruments often buy:
• W1716EP Digital Pre-Distortion Builder
• W1905EP Radar Model Library
• W1902EP Digital Modem Library
• W1918EP LTE-Advanced Baseband Verification Library
Softw are Information
M a i n F e a tur e s and B e ne fi t s
14
74
Product features
Your benefits
Popular modeling languages: C++,
MATLAB .m, HDL, or graphical
dataflow schematics
Open, vendor-neutral formats
reduce costs and connect Agilent
Test with Enterprise EDA tools
Superior RF simulation speed &
accuracy, with links to RF EDA
Virtualize RF/MIMO components
for earliest system validation with
high confidence
World-class IP references for LTEAdvanced, 802.11ac/ad, Radar,
and other standards
Create and re-use TX/RX and
MIMO verification suites with
confidence across the whole
lifecycle from design to test
Superior integration of Simulation
with Test & Measurement
Bring “Drive Test” accuracy into
4G design, while creating custom
personalities around test
Interoperates with a wide
variety of Agilent equipment and
software, including 89600 VSA
and Command Expert
Makes highest use of best-incategory assets, while unifying
DSP and RF design lifecycles into
a coherent flow
Software operating
systems
Microsoft Windows 8 (32/64-bit)
Microsoft Windows 7 (32/64-bit)
Microsoft Windows XP (32-bit)
Available Addon Applications
and Design Flow
Personalities
Fixed-point models, HDL Code-Generation,
C++ Code Generation, Adaptive EQ, DPD
Builder, MIMO Channel Builder, RF System
Architectures
Available Standards
Reference Libraries
Comms: LTE-Advanced, LTE, HSPA+,
WCDMA, cdma2000® , CDMA, WiMAX™,
802.11a/ac/ad, DVB-S2/T2, Custom OFDM,
Bluetooth, Zigbee, and nearly 40 general
purpose formats for Milcomm/Satcomm.
Radar: Doppler, UWB, SAR, DAR,
FMCW, Phased Array, Beamforming
Agilent software
applications that are
tightly integrated with
SystemVue
Agilent test software: 89600 VSA,
FlexDCA, I/O Libraries, Command Expert,
Waveform Creator.
Agilent EDA software: Advanced Design
System, GoldenGate
3rd party applications
and development
environments that are
integrated with
SystemVue
Microsoft VisualC++,MATLAB, VHDL/
Verilog, FPGA Hardware-in-Loop, (HIL), STK
(Analytical Graphics) and more.
M9391A
NEW
Agilent M9391A
PXIe Vector Signal Analyzer
www.agilent.com/find/m9391a
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations and Charac teristic s
• Cellular picocell and femtocell test
Hardware
• RF component manufacturing test
Frequency range
1 MHz to 3 GHz or 6 GHz
fastune switching speed
Frequency switching up to 15 µs, nominal
Phase noise
< -120 dBc/Hz (1 GHz, 20 kHz offset)
Repeatability
<0.05 dB, nominal
Amplitude accuracy
±0.45 dB, typical
Analysis bandwidth
40 MHz (flatness: ±0.08 dB, nominal)
100 MHz (flatness: ±0.09 dB, nominal)
160 MHz (flatness: ±0.17 dB, nominal)
WLAN 802.11ac
-47.5 dB,
5.8 GHz, 160 MHz BW
nominal
W-CDMA -68.1 dBc, typical (adjacent)
W-CDMA -70.7 dBc, typical (alternate)
4-slot
• Wireless transceiver design validation
• WLAN production test
• Military radio test
• Public safety and homeland security radio test
P r o d u c t D e scr i p t i o n
The Agilent M9391A PXIe vector signal analyzer (PXI VSA)
is a modular solution that provides frequency coverage
from 1 MHz to 6 GHz and works seamlessly with the
M9381A PXI VSG. The combined PXI VSA/G provides a
complete solution for fast, high quality measurements
optimized for RF manufacturing test environments.
In addition to the raw hardware speed enabled by Agilent's
exclusive technology innovations, the PXI VSA produces
high quality measurements. Agilent's industry leading
software applications further increase the efficiency of the
PXI VSA, including X-series measurement applications.
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefit
Fast amplitude and frequency
switching speed with fastune
Accelerate test throughput
Embedded power measurement
mode
Reduces test times from 3s to
less than 600 ms with outstanding
linearity
Unique resource manager
in X-Series Measurement
Applications for modular
instruments
Provides fast switching between
raw data measurements and
standards-based measurements.
Chassis slot compatibility: PXIe, PXIe Hybrid
EVM
ACLR
Size
Ordering Information
Model
Description
M9391A
PXIe vector signal analyzer: 1 MHz to 3 or 6 GHz
Includes: M9301A PXIe synthesizer, M9350A
PXIe downconverter, M9214A PXIe IF digitizer
Base Configuration
M9391A-F03
Frequency range: 1 MHz to 3 GHz
M9391A-B04
Analysis bandwidth: 40 MHz
M9391A-M01
Memory: 128 MSa
M9391A-300
Required for
warranted
specifications
PXIe frequency reference: 10 MHz and 100 MHz
Adds M9300A PXIe frequency reference: 10
MHz and 100 MHz (M9300A module can support
multiple M9391A modular instruments)
14
Other Options
M9391A-F06
Frequency range: 1 MHz to 6 GHz
M9391A-UNZ
Fast switching
M9391A-B10
Analysis bandwidth: 100 MHz
M9391A-B16
Analysis bandwidth: 160 MHz
M9391A-M05
Memory: 512 MSa
M9391A-M10
Memory: 1024 MSa
75
DUAL CH VSA
Agilent
Dual Channel PXI
Vector Signal Analyzer
www.agilent.com/find/pxi-vsa-dualchannel
I n d u s tr i e s and A p p l i cat i o ns
• Aerospace and defense
Hardware
• Wireless communications
Channel
Up to 2 channels in a single chassis
Frequency range
50 MHz to 26.5 GHz
Sample rate
2 GS/s
3 dB Bandwidth
35 MHz min (preselected, < 3 GHz)
40 MHz min (preselected, ≥ 3 GHz)
40 MHz min (< 2.75 GHz, bypass)
250 MHz min (≥ 2.75 GHz, bypass)
Up to 100 MHz streamed analog bandwidth
on each channel
• Radar and wideband signal capture
• Electronic test
P r o d u c t D e scr i p t i o n
The Dual Channel PXI Vector Signal Analyzer is designed
to deliver simultaneous, wide bandwidth analysis of two
RF/Microwave signals. For applications requiring gapless
recording over long durations, this configuration enables
simultaneous streaming of each channel—at up to 100
MHz analog bandwidth—to a local drive or large capacity
RAID storage device. Streaming detects elusive problems
that may be missed by single capture analysis to find the
root cause of intermittent issues.
M a i n F e a tur e s and B e ne fi t s
14
Spec ific ations and Charac teristic s
Product features
Your benefit
Multichannel analysis
Detect and identify sources of
interference
100 MHz streaming capability
Capture and analyze intermittent
problems at high frequencies and
bandwidths.
Real-time digital
downconversion (DDC)
algorithm
Data decimation, analog
performance improvement
Seamless integration with
Agilent 89600 VSA software
Immediate access to the
industry’s broadest, most
advanced standards-based
demodulation and signal
analysis
Chassis slot compatibility: PXIe, PXIe Hybrid
76
Maximum streamed
analog bandwidth
(config dependent)
EVM
DANL
Absolute amplitude
accuracy
< -40 dB at 80 MHz BW, 5.8 GHz
(nominal)
-158 dBm/Hz, ≤ 9.5 GHz, (nominal)
-147 dBm/Hz, > 9.5 GHz, (nominal)
± 0.6 dB, < 2.75 GHz, (nominal), after
field calibration (corrected)
± 0.5 dB, ≥ 2.75 GHz, (nominal), after
field calibration (corrected)
± 2 dB, (nominal), without field
calibration (uncorrected)
Ordering Information
Model
Description
M9392A
PXI microwave vector signal analyzer
(1 for each channel)
Optional Modules
M9351A
PXI downconverter: 50 MHz to 2.9 GHz
(1 for each channel)
89600 VSA Software
89601B
89600 VSA software, transportable license
89601B-200
Basic vector signal analysis
89601B-300
Hardware connectivity
89601B-AYA
Vector modulation analysis
For more detailed configuration information, please see the M9392A
Configuration Guide, literature no. 5990-8254EN.
M9392A
Agilent M9392A
PXI Vector Signal Analyzer
50 MHz to 26.5 GHz
www.agilent.com/find/m9392a
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations
• Aerospace and defense
Hardware
• Wireless communications
Frequency range
50 MHz to 26.5 GHz
• Digital pre-distortion (DPD)
Size
7 or 8 slots-wide multiple modules
Sample rate
2 GS/s
3 dB bandwidth
35 MHz min (preselected, < 3 GHz)
P r o d u c t D escr i p t i o n
The Agilent M9392A1 is a PXI Vector Signal Analyzer
with frequency coverage from 50 MHz to 26.5 GHz with
250 MHz of instantaneous bandwidth and up to 100
MHz streamed analog bandwidth. Achieve multichannel
analysis capability by combining 2 PXI vector signal
analyzers--Agilent M9392A--in one chassis. Combine with
the Agilent 89600 VSA software, for a complete Microwave
Vector Signal Analyzer solution enabling analysis of
communications, radar, and avionics signals in a modular,
open-system standard.
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefit
12-bit, 2 GS/s digitizer
Measure broadband
communications and radar signals
Multichannel analysis
Detect and identify sources of
interference. Measure 80+80 MHz
802.11ac devices
Real-time digital downconversion (DDC) algorithm
Data decimation, analog
performance improvement
Seamless integration with
Agilent 89600 VSA software
Immediate access to the industry’s
broadest, most advanced standardsbased demodulation and signal
analysis
Chassis slot compatibility: cPCI (J1), PXI-1, PXI Hybrid
40 MHz min (preselected, ≥ 3 GHz)
40 MHz min (< 2.75 GHz, bypass)
250 MHz min (≥ 2.75 GHz, bypass)
Maximum streamed
analog bandwidth (config
dependant)
up to 50 MHz (with V05 option)
up to 100 MHz (with V10 option)
EVM
< -40 dB at 80 MHz BW, 5.8 GHz (nominal)
DANL
-158 dBm/Hz, ≤ 9.5 GHz, (nominal)
-147 dBm/Hz, > 9.5 GHz, (nominal)
Absolute amplitude
accuracy
± 0.6 dB, < 2.75 GHz, (nominal), after field
calibration (corrected)
± 0.5 dB, ≥ 2.75 GHz, (nominal), after field
calibration (corrected)
± 2 dB, (nominal), without field calibration
(uncorrected)
Ordering Information
14
Model
Description
M9392A
PXI Vector Signal Analyzer 50 MHz to 26.5 GHz
Includes: M9202A PXIe IF digitizer, M9302A PXI
local oscillator, M9360A PXI attenuator/preselector,
M9351A and M9361A PXI downconverters
M9018A
18-slot PXIe Chassis
M9036A
PXIe Embedded Controller
89601B
89600 VSA software, transportable License
89601B-200
Basic vector signal analysis
89601B-300
Hardware connectivity
89601B-AYA
Vector modulation analysis
77
WIDEBND MIMO
Agilent Wideband
MIMO PXI Vector Signal Analyzer
www.agilent.com/find/pxi-vsa-mimo
I n d u s tr i e s and A p p l i cat i o ns
• 802.11ac applications
Hardware
• Wireless device test
Channel
Up to 4 channels in a single chassis
Frequency Range
10 MHz to 26.5 GHz
• Wireless transceiver design validation
Analysis Bandwidth
Up to 800 MHz
• WLAN production test
Error Vector Magnitude
< - 42 dB Exceeds 802.11ac standards
IF Digitizer resolution
12-bits
Sample Rate
2 GS/s
Size
4U rack space for 3 channel configuration
P r o d u c t D escr i p t i o n
The wideband MIMO PXI Vector Signal Analyzer delivers
simultaneous, wide bandwidth analysis on up to 4 channels. For engineers working on 802.11ac applications, this
PXI configuration provides analysis capabilities for up to
4x4 MIMO, and is ideal for 80 + 80 MHz SISO, and 80 MHz
or 160 MHz MIMO 802.11ac measurements. Additionally,
it provides up to 800 MHz analysis bandwidth to address
current and future wireless standards.
M a i n F e a tur e s and B e ne fi t s
14
Spec ific ations and Charac teristic s
Product features
Your benefit
Flexible 2 to 4 channels
Analysis capabilities for up to 4x4
MIMO
800 MHz Analysis Bandwidth
Supports current and future
wireless standards
Seamless integration with Agilent
89600 VSA software
Immediate access to the
industry’s most advanced
standards based demodulation
and signal analysis
Support of 802.11ac format
Standards-based measurements
Physical layer parametric
measurements
Analyze EVM by symbol, carrier
or burst, measure I/Q parameters,
center frequency, bandwidth, power,
ACPR, demodulate to bit level
Chassis slot compatibility: PXIe, PXIe Hybrid
78
Ordering Information
Model
Description
M9018A
PXIe 18 slot chassis
M9036A
PXIe embedded controller
M9202A
12-bit 2 GSa/s IF digitizer ( 1 module per channel)
M9362A-001
4-channel downconverter
M9352A
4-channel IF amplifier/attenuator
M9302A
Local oscillator (1 module for 1 to 3 channels)
M9168C
PXIe attenuator (1 module per channel)
89600 VSA Software
89601B
89600 VSA software, transportable license
89601B-200
Basic vector signal analysis
89601B-300
Hardware connectivity
89601B-AYA
Vector modulation analysis
89601B-B7Z
WLAN 802.11n modulation analysis
89601B-BHJ
WLAN 802.11ac modulation analysis
Cables
Y1240A Option 001
2-Channel trigger distribution kit
Y1240A Option 002
3 and 4-channel trigger distribution kit
Y1240A Option 003
3 and 4-channel 100 MHz distribution kit
Y1240A Option 004
LO distribution kit
Y1240A Option 005
2-channel RF distribution kit
For detailed configuration information, please see the M9362A-D01
Configuration Guide, literature no. 5990-9968EN.
M9362A-D01
Agilent M9362A-D01
PXIe Microwave Quad
Downconverter
www.agilent.com/find/m9362a-d01
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations
Hardware
• Aerospace and defense
• Wireless communications
• Radar and wideband signal capture
P r o d u c t D e scr i p t i o n
The Agilent M9362A-D01, option F26, is a PXIe 3-slot,
4-channel, coherent microwave downconverter with
frequency coverage from 10 MHz to 26.5 GHz, along with
1.5 GHz of instantaneous bandwidth per channel. The
M9362A-D01 is well suited for wideband signal capture
where multiple channels are required for applications such
as multi-channel coherent signal analysis, radar, SIGNIT,
ELINT, MASINT, EW signal capture and analysis, and RF
and microwave recording and analysis.
When combined with an Agilent M9302A Local Oscillator
and one or more Agilent M9210A 4GS/s Digitizers, the
M9362A-D01 Downconverter can be used to synchronously
capture up to 4 signals in up to 1.4 GHz bandwidth, with
10-bit resolution.
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefit
Frequency range
10 MHz to 26.5 GHz
Four-channel synchronous
downconversion
Multi-channel coherent signal
analysis
PXIe form-factor
Conforms to Modular Open
Systems Approach (MOSA)
Software support for easy
integration
Reduced development time
Size
3-slot
Operating Range
10 MHz to 26.5 GHz
Bandwidth
1.5 GHz per channel
Noise Figure
24 dB, (nominal)
Impedance
50 Ω, (nominal)
Ordering Information
Model
Description
M9362A-D01
PXIe Quad Downconverter:
M9362AD01-F26
10 MHz to 26.5 GHz
M9362AD01-CA1
IF Jumper Cables for use with 4-M9202A
Single CH Digitizers
M9362AD01-CA2
IF Jumper Cables for use with 2-M9202A Dual
CH Digitizers
M9362AD01-CA3
IF Jumper Cables for use with the M9210A
M9362AD01-CA4
LO Interconnect Kit for use with the M9302A
Related Products
M9302A
PXI Local Oscillator: 3 GHz to 10 GHz
M9210A
PXI-H High-speed Digitizing Scope: 10-bit, 2-4
GS/s
M9018A
18-slot PXIe chassis
M9036A
PXIe Embedded Controller
14
Chassis slot compatibility: PXIe, PXIe hybrid 79
M9168C
Agilent M9168C
PXI Programmable Step
Attenuator Module
www.agilent.com/find/pxiattenuator
I n d u s tr i e s and A p p l i cat i o ns
•
•
•
•
RF signal path attenuation simulation
Engineering verification
RF receiver sensitivity test
Adjacent channel interference
P r o d u c t D escr i p t i o n
M9168C is a programmable step attenuator module based
on the PXI hybrid platform, operating from DC to 26.5 GHz
with a guaranteed 0.03 dB insertion loss repeatability for
each section throughout the 5 million cycles operating life.
Its excellent attenuation accuracy across a wide operating
temperature range, ensures precise measurement.
M9168C is a signal conditioning module that enhances the
measurement accuracy and flexibility of PXI based RF and
microwave test systems.
M a i n F e a tur e s and B e ne fi t s
14
Product features
Your benefit
Guaranteed 0.03 dB insertion
loss repeatability throughout the
operating life of up to 5 million
cycles
Reduce downtime for recalibration,
improve testing efficiency,
therefore maximizing throughput
Broad attenuation range of 0 to
101 dB with 1 dB step
Maximize measurement accuracy
and system flexibility
High attenuation accuracy and
flatness of +/- 0.4 dB at 26.5 GHz
Superior attenuation accuracy
ensures precise measurements,
across a wide temperature range
Chassis slot compatibility:
80
cPCI, PXI-H, PXI-1
Spec ific ations
Hardware
Size
2 slots wide module
Frequency
DC to 26.5 GHz
Attenuation
resolution
1 dB, 5 dB and 10 dB step
Attenuation
accuracy
Refer to Table 1 on page 2. Specified across
operating frequency of 0°C to 50°C
Repeatability
0.03 dB guaranteed
Life cycle
5 million cycles per section (guaranteed)
Maximum input
power
1 W (+30 dBm) avg. 50 W peak, (10 μs max)
Maximum reverse
power
1 W avg. 50 W peak (10 μs max)
RF connector
3.5 mm (f), SMA compatible
Ordering Information
Model
Description
M9168C
PXI-h Programmable Attenuator Module,
DC to 26.5 GHz
Typical product configuration
M9018A
PXIe Chassis, 18- slots, 3U, 8 GB/s
M9202A
PXIe IF Digitizer: 12-Bit, 1 GHz
M9361A
PXI Downconverter: 2.75 to 26.5 GHz
M9168C
PXI-h Programmable Attenuator Module,
DC to 26.5 GHz
Related products
M9392A
PXI Vector Signal Analyzer
M9351A
PXI Downconverter (50 MHz to 2.9 GHz)
M9360A
PXI Attenuator/Preselector
M9155/6/7C
PXI Switch Modules, DC to 26.5 GHz
M9202A
Agilent M9202A
PXI Express 12-bit
Wideband IF Digitizer
www.agilent.com/find/m9202a
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations and Charac teristic s
Hardware
• Aerospace and defense
• Wireless communications
• Radar and wideband signal capture
P r o d u c t D escr i p t i o n
The M9202A PXIe Wideband IF Digitizer runs at 2 GS/s,
with up to 1 GHz instantaneous analog bandwidth and
offers DDR3 memory. Through firmware options and
the Xilinx Virtex-6 FPGA, the M9202A provides different
functionalities. The BAS option provides basic digitizer
functionality (signal capture, storing of data, transfer of
data, etc). The DDC option additionally offers real-time
digital down-conversion (DDC) algorithm in the 300 MHz to
700 MHz band, enabling improved analog performance and
reducing data upload time.
M a i n F e a tur e s and B e ne fi t s
Size
1 slot 3U
Resolution
12 bits
Sample rate
2 GS/s
Bandwidth
30 MHz (nominal) to 1 GHz
Streamed analog bandwidth
up to 50 MHz, or up to 100 MHz
Impedance
50 Ω (nominal)
Coupling
AC
Full scale (FS) range
+4 dBm (1 V pk-pk in 50 Ω)
Spurious-free dynamic range
(SFDR)
60 dBc (typical) in basic digitizer mode
84 dBc (typical) after digital downconversion (with DDC option)1
Effective number of bits
(ENOB)
9 bits (typical)
Sample clock sources
Internal (with internal or external
100 MHz ref) or external
Ordering Information
Model
Description
M9202A
PXIe IF Digitizer: 12-bit, 1 GHz
M9202A-C01
Single channel
M9202A-F02
Frequency range: 2 GS/s
M9202A-M05
Standard memory: 512 MB
Product features
Your benefit
2 GS/s sampling rate
Fastest 12-bit PXIe Digitizer
Up to 1 GHz bandwidth
Able to capture wide bandwidth
signals
Related products
512 MB DDR3 memory
Large on-board memory
M9302A
PXI Local Oscillator: 3 GHz to 10 GHz
Real-time digital down-conversion
(DDC) algorithm
Data decimation, analog
performance improvement
M9351A
PXI Downconverter: 50 MHz to 2.9 GHz
On-board Xilinx Virtex-6 FPGA
On-board processing capability
M9361A
PXI Downconverter: 2.75 GHz to 26.5 GHz
Software support for easy
integration
Reduced development time
M9362A-D01
PXIe MW Quad Downconverter: 10 MHz to 26.5 GHz
M9360A
PXI Attenuator/Preselector: 100 kHz to 26.5 GHz
M9392A
PXI Vector Signal Analyzer
M9211A
PXI-H UWB IF Digitizer: 10-bit, 4 GS/s, 3 GHz
M9018A
18-slot PXIe Chassis
M9021A
PCIe® Cable Interface
89601B
89600 VSA software
PXIe backplane
Fastest digitized data upload,
continuous data steaming
Chassis slot compatibility: PXIe Hybrid, PXIe
For complete list of available options, please see datasheet.
14
81
M9302A
Agilent M9302A
PXI Local Oscillator
www.agilent.com/find/m9302a
I n d u s tr i e s and A p p l i cat i o ns
• Aerospace and defense
Hardware
• Wireless communications
Size
2 slot 3U
Phase noise
-115 dBc/Hz at 10 GHz, 10 kHz offset
Frequency switching
speed
1 ms, 500 µs, typical
Power
+16 dBm ± 2 dB
Frequency output
REF OUT: 10 MHz, (nominal)
• Radar and wideband signal capture
P r o d u c t D escr i p t i o n
The Agilent M9302A PXI Local Oscillator (LO) is a VCObased 3 GHz to 10 GHz LO optimized for fast settling time
to allow for fast frequency down conversion applications.
The fast switching time and low phase noise of this LO
make it an ideal component of a microwave vector signal
analyzer.
M a i n F e a tur e s and B e ne fi t s
14
Spec ific ations
Product features
Your benefit
Frequency range
3 GHz to 10 GHz
0.1 Hz tuning resolution
Greater frequency accuracy
1 ms settling time
Speeds up your test time
Multiple programmatic interfaces
Easy integration into existing
test environments and reduced
development time
PXI form-factor
Conforms to Modular Open
Systems Approach (MOSA)
Chassis slot compatibility: cPCI (J1), PXI-1, PXI Hybrid
82
REF 1 OUT: 100 MHz, (nominal)
REF 2 OUT: 100 MHz, (nominal)
Amplitude
REF OUT: 0 dBm ± 3 dB (at 25 °C ± 5 °C)
REF 1 OUT: 0 dBm ± 3 dB (at 25 °C ± 5 °C)
REF 2 OUT: 0 dBm ± 3 dB (at 25 °C ± 5 °C)
Frequency
± 0.5 ppm (over 0 °C to 50 °C)
temperature stability
Aging (after 30 days
of operation)
± 1.0 ppm/year
Ordering Information
Model
Description
M9302A
PXI Local Oscillator: 3 GHz to 10 GHz
Related products
M9202A
PXIe IF Digitizer: 12-bit, 2 GS/s
M9360A
PXI Attenuator/Preselector:
100 kHz to 26.5 GHz
M9361A
PXI Downconverter:
2.75 MHz to 26.5 GHz
M9351A
PXI Downconverter: 50 MHz to 2.9 GHz
M9392A
PXI Vector Signal Analyzer:
50 MHz to 26.5 GHz
M9036A
PXIe Embedded Controller
M9351A
Agilent M9351A
PXI Downconverter
www.agilent.com/find/m9351a
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations
• Aerospace and defense
Hardware
• Wireless communication
Size
1 slot 3U
Frequency range
50 MHz to 2.9 GHz
• Radar and wideband signal capture
P r o d u c t D escr i p t i o n
The Agilent M9351A is a one-slot 3U PXI Downconverter
that converts RF signals from 50 MHz to 2.9 GHz into
baseband frequency signals for use with Agilent’s newest
generation of PXI digitizers. The built-in pre-amp enables
very low level signal measurements, down to -160 dBm,
and the built-in calibration simplifies system power budget
calculations.
M a i n F e a tur e s and B e ne fi t s
50 MHz to 625 MHz (usable to 1 MHz)
(bypass mode)
Operating range
-160 dBm to -30 dBm, (nominal)
Bandwidth (3 dB)
40 MHz, min
RF to IF Gain
38 dB, (nominal)
Center frequency
(user adjustable)
500 MHz, (nominal)
Residuals, RF and LO input
terminated
-75 dBm
LO input frequency range
3.5 GHz to 6.4 GHz
LO input power
+15 dBm ± 2 dB
Impedance
50 Ω, (nominal)
Ordering Information
Product features
Your benefit
Built-in pre-amp
Able to acquire low-level signals
Image protected conversion
No need for a preselector
Model
Description
Bypass path
Route specific signals directly to
the digitizer
M9351A
PXI Downconverter: 50 MHz to 2.9 GHz
40 dB solid state IF attenuator with
0.5 dB steps
Fast IF power control
Related products
M9302A
PXI Local Oscillator: 3 GHz to 10 GHz
Multiple programmatic interfaces
Easy integration into existing
test environments and reduced
development time
M9202A
PXIe IF Digitizer: 12-bit, 2 GS/s
M9360A
PXI Attenuator/Preselector: 100 kHz to 26.5 GHz
M9361A
PXI Downconverter: 2.75 MHz to 26.5 GHz
M9392A
PXI Vector Signal Analyzer: 50 MHz to 26.5 GHz
M9018A
18-slot PXIe Chassis
M9036A
PXIe Embedded Controller
Chassis slot compatibility: cPCI (J1), PXI-1, PXI Hybrid
14
83
M9352A
Agilent M9352A
PXI Hybrid Amplifier/Attenuator
www.agilent.com/find/m9352a
I n d u s tr i e s and A p p l i cat i o ns
• Aerospace/defense
Hardware
• Wireless communications
Size
One-slot
Channels
4
Bandwidth
1 GHz analog
Attenuation Range
31.5 dB in .5 dB steps
Minimum Gain:
Maximum Gain:
≥ 5 dB
≥ 36 dB
Noise Figure
3 dB
Input TOI
+43 dBm
• Radar and wideband signal capture
P r o d u c t D escr i p t i o n
The Agilent M9352A is a one-slot, 4-channel, PXI Hybrid IF
Amplifier/Attenuator with 1 GHz analog bandwidth providing excellent IF signal conditioning for use in multi-channel
modular solutions.
Combine with the M9362A-D01 PXI Quad Downconverter,
up to four M9202A IF Digitizers, and a local oscillator for
wideband signal capture where multiple channels are
required for applications such as multi-channel coherent
signal analysis.
Ma i n F e a tur e s and B e ne fi t s
14
Charac teristic Performanc e
Ordering Information
Model
Description
M9352A
PXI Amplifier/Attenuator Module: 1 GHz
Related Products
M9018A
18-slot PXIe Chassis
M9036A
PXIe Embedded PC Controller
M9202A
PXIe IF Digitizer: 12-bit, 2 GS/s (with options
CO1, FO2, MO5, DDC)
M9202A-V05
50 MHz BW Streaming
Product features
Your benefits
Frequency range
10 MHz to 1 GHz
M9202A-V10
100 MHz BW Streaming
Multiple programmatic interfaces
Easy integration into existing
test environments and reduced
development time
M9302A
PXI Local Oscillator: 3 GHz to 10 GHz
M9362A-D01
PXIe Quad Downconverter: 10 MHz to 26.5 GHz
M9362AD01-CA1
IF Jumper Cables for use with 4-M9202A Single
CH Digitizers
M9362AD01-CA2
IF Jumper Cables for use with 2-M9202A Dual CH
Digitizers
M9362AD01-CA3
IF Jumper Cables for use with the M9210A
M9362AD01-CA4
LO Interconnect Kit for use with the M9302A
PXI form-factor
Conforms to Modular Open
Systems Approach
Chassis slot compatibility: cPCI (J1), PXI-1, PXIe hybrid
84
M9360A
Agilent M9360A
PXI Attenuator/Preselector
www.agilent.com/find/m9360a
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations
• Aerospace and defense
Hardware
• Wireless communications
Frequency range
100 kHz to 26.5 GHz
• Radar and wideband signal capture
Size
3 slot 3U
Tuning speed
< 5 ms @ 50 MHz step, (nominal)
P r o d u c t D escr i p t i o n
Maximum power
RF IN: +30 dBm
The M9360A PXI Attenuator/Preselector is a 3-slot 3U,
combination module providing attenuation and preselection signal conditioning for numerous system applications
with an electronically tuneable, 4-stage, YIG-tuned filter
based RF-input pre-selector, and broadband switches for
signal distribution.
3 dB bandwidth
LO IN: +20 dBm
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefit
Bypass path
Automatically route signals around
the band limited preselector for
additional bandwidth
35 MHz to 120 MHz bandwidth
(preselected, < 3 GHz)
40 MHz to 120 MHz bandwidth
(preselected, ≥ 3 GHz)
35 MHz min, 120 MHz max (preselected,
< 3 GHz)
40 MHz min, 120 MHz max (preselected,
≥ 3 GHz)
Attenuator
0 dB to 70 dB in 10 dB steps
Switches
SP2T mechanical type
Ordering Information
Model
Description
M9360A
PXI Attenuator/Preselector:
100 kHz to 26.5 GHz
Related products
Allows you to analyze large
bandwidth signals
70 dB input step attenuator
Increased dynamic range
Multiple programmatic interfaces
Easy integration into existing
test environments and reduced
development time
Chassis slot compatibility: cPCI (J1), PXI-1, PXI Hybrid
M9202A
PXIe IF Digitizer: 12-bit, 2 GS/s
M9302A
PXI Local Oscillator: 3 GHz to 10 GHz
M9361A
PXI Downconverter: 2.75 MHz to 26.5 GHz
M9351A
PXI Downconverter: 50 MHz to 2.9 GHz
M9392A
PXI Vector Signal Analyzer:
50 MHz to 26.5 GHz
M9018A
18-slot PXIe Chassis
M9036A
PXIe Embedded Controller
14
85
M9361A
Agilent M9361A
PXI Downconverter
www.agilent.com/find/m9361a
I n d u s tr i e s and A p p l i cat i o ns
• Aerospace and defense
Hardware
• Wireless communications
Size
1 slot 3U
Frequency range
2.75 GHz to 26.5 GHz
Operating range
< 9.5 GHz: -160 dBm to -30 dBm, (nominal)
• Radar and wideband signal capture
9.5 GHz to 26.5 GHz: -146 dBm to -30 dBm,
(nominal)
P r o d u c t D e scr i p t i o n
The M9361A is a one-slot 3U PXI Downconverter that
converts microwave signals from 2.75 GHz to 26.5 GHz into
baseband frequency signals centered at an IF frequency
of 500 MHz. The built-in pre-amp enables very low level
signal measurements, down to -160 dBm, and built-in
calibration simplifies system power budget calculations.
M a i n F e a tur e s and B e ne fi t s
14
Spec ific ations
Product features
Your benefit
250 MHz bandwidth
Able to capture wide bandwidth
signals
Built-in pre-amp
Able to acquire low-level signals
40 dB solid state IF attenuator
with 0.5 dB steps
Fast IF power control
Auxiliary input/switch for signal
routing
Effectively gives you the option to
route signals directly from other
downconverters to a digitizer
without external switching
Multiple programmatic interfaces
Easy integration into existing
test environments and reduced
development time
Chassis slot compatibility: cPCI (J1), PXI-1, PXI Hybrid
86
Bandwidth (3 dB)
250 MHz, min
Impedance
50 Ω, (nominal)
RF to IF Gain
38 dB, (nominal)
Center frequency
(user adjustable)
500 MHz, (nominal)
Residuals, RF and
LO input terminated
-75 dBm
LO input frequency
range
3 GHz to 10 GHz
LO input power
+15 dBm ± 2 dB
Impedance
50 Ω, (nominal)
Ordering Information
Model
Description
M9361A
PXI Downconverter: 2.75 GHz to 26.5 GHz
Related products
M9302A
PXI Local Oscillator: 3 GHz to 10 GHz
M9202A
PXIe IF Digitizer: 12-bit, 2 GS/s
M9360A
PXI Attenuator/Preselector:
100 kHz to 26.5 GHz
M9351A
PXI Downconverter: 50 MHz to 2.9 GHz
M9392A
PXI Vector Signal Analyzer:
50 MHz to 26.5 GHz
M9018A
18-slot PXIe Chassis
M9036A
PXIe Embedded Controller
PXI SIGNAL GENERATORS ( SOURCE)
Achieve confidence and continuity in measurements
Agilent's modular products combined with its broad portfolio of world-class software applications accelerate your
project's design to manufacturing cycle. From model-based system level design validation, to detailed measurement data analysis of complex devices to RF standard conformance measurements, Agilent provides ways to
achieve more confidence and continuity in measurements from R&D to manufacturing.
Features and benefits
Reduce your RF test time and accelerate test throughput with the M9381A PXIe Vector Signal Generator's fast
amplitude and frequency switching speeds. The one-step software installation, integrated soft front panel and
one day start up assistance service provided by an Agilent expert will help you get started quickly making your first
measurements. The M9381A PXIe VSG, M9380A PXIe CW Source and M9300A PXIe Frequency Reference are all
backed by Agilent’s 3 year warranty and worldwide technical support organization.
SystemVue is a focused electronic design automation (EDA) environment
for electronic system level (ESL) design. It enables system architects and
algorithm developers to innovate the physical layer (PHY) of wireless and
aerospace/defense communication systems. Superior integration with
PXI modular instruments accelerates real-world maturity and streamlines
your model-based design flow from architectures to verification
Signal Studio is a flexible suite of easy to use signal creation tools
that reduce the time spent on signal creation and simulation. With
Signal Studio you can create performance optimized reference signals
validated by Agilent, supporting a wide variety of communications
standards including LTE, W-CDMA, and WLAN 802.11ac.
Waveform Creator provides easy development of complex
NEW
baseband and vector signals used in the validation and
test of digital communications products. It supports multiple
waveform types and instruments to be "plugged in" for design
validation.
www.agilent.com/find/pxi-vsg
P XI SI G NA L G ENE RA TO RS (S OU RCE )
Agilent's growing family of PXIe RF Signal Generators and Signal Analyzers includes the recently released M9381A
PXIe Vector Signal Generator, which provides fast, high quality measurements with an exclusive baseband tuning technology innovation. The M9381A PXIe VSG works seamlessly with the new M9391A PXIe Vector Signal
Analyzer to provide a complete solution that includes software, programming examples and services aimed at
reducing the cost of RF manufacturing test.
PXI SIGNAL GENERATORS ( SOURCE)
P XI S I G NAL GENE RA TO RS (S OU RCE )
PXI Signal Generator Modules
Model
Description
Type
# of slots
Frequency
range
Frequency
switching
speed
Output power
Level
accuracy
SSB phase noise
(1 GHz, 20 kHz
offset)
Harmonics
Internal
baseband
generator
RF BW
M9300A
PXIe
Frequency
Reference
PXIe,
PXI Hybrid
1-slot
100 MHz
(Out 1 to 5)
10 MHz
n/a
≥ 10 dBm
(100 MHz out)
n/a
< -168 dBc/Hz
(nominal)
n/a
n/a
M9380A
PXIe CW
Source
PXIe,
PXI Hybrid
3-slot
1 MHz to 6
GHz
5 ms
(nominal)
+18 dBm
(1 MHz to 5 GHz)
+19 dBm
(> 5 to 6 GHz)
±0.4 to
1 dB
< –122 dBc/Hz
(typical)
< -29 dBc
n/a
M9381A
PXIe
Vector
Signal
Generator
PXIe,
PXI Hybrid
5-slot
1 MHz to 6
GHz
< 10 μs
to 240 μs
(nominal)
+18 dBm
(1 MHz to 5 GHz)
+19 dBm
(> 5 to 6 GHz)
±0.4 to
1 dB
< –122 dBc/Hz
(typical)
< -35 dBc
160 MHz
Software Applications for PXI Signal Generators
Model
Description
Modular Instruments Supported
M9099
Waveform Creator
M9381A PXIe Vector Signal Generator
W1461BP
SystemVue
M9381A PXIe Vector Signal Generator
M9391A PXIe Vector Signal Analyzer
N7600B N7625B
Signal Studio
M9381A PXIe Vector Signal Generator
Driver information
Supported operating systems
Microsoft Windows 7 (32/64-bit), Windows Vista (32/64-bit), Windows XP (32-bit)
Standard compliant drivers
IVI-COM, IVI-C, LabVIEW, MATLAB
Supported application development environments (ADE)
Visual Studio (VB.NET, C#, C/C++), VEE, LabVIEW, LabWindows/CVI, MATLAB
Agilent IO Libraries
Includes: VISA Libraries, Agilent Connection Expert, IO Monitor
www.agilent.com/find/pxi-vsg
WAVEFORM CREATOR
NEW
Agilent M9099
Waveform Creator Software
www.agilent.com/find/m9099
I n d u s tr i e s and A p p l i cat i o ns
• Satellite communcations
Ordering Information
Model
Description
M9099T
Waveform Creator software - transportable,
perpetual license
M9099T-LIC
Core product w/utility & multi-tone plug-ins
(required)
P r o d u c t D escr i p t i o n
M9099T-LIC-12M
Premium support program - 1 year
Waveform Creator is a modular software application
focused on easy development of complex baseband and
vector signals used in the validation and test of digital
communications products. Built around a drag and drop
graphical user interface, Waveform Creator allows quick
development of multi-format, multi-track waveforms with
waveform segments displaced in frequency and time. Its
modularity supports multiple waveform types and VSG/
AWG instruments to be "plugged in" for current and future
waveform types and instruments.
M9099T-AYA
Digital modulation plug-in
M9099T-AYA-12M
Premium support program - 1 year
M9099T-SVM
SystemVue plug-in licenses (requires SystemVue
software)
M9099T-SVM-12M
Premium support program - 1 year
M9099T-DFW
File-based write (unencrypted waveform license)
M9099T-DFW-12M
Premium support program - 1 year
M9099T-MED
Software & documentation media (DVD)
• Military communications and secure backhaul
• Component validation with wideband test equipment
Premium support program renewals available
Softw are Information
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefits
Plug in capability supporting
popular digital modulation and
custom waveforms
Saves you time and effort to
create and manage complex
waveforms
Simple interface to set desired
signal parameters and compose
waveform segments
Powerful capabilities delivered in
easy to use, intuitive interface
List of functional waveform plugins or develop your own
Starting points provided to easily
customize waveforms
Playback waveforms on M9381A
PXIe Vector Signal Generator
Standard output plug-in for quick
deployment
Software operating
systems
Microsoft Windows 7 (32/64-bit)
Agilent software
applications that are
tightly integrated with
Waveform Creator
Agilent test software: 89600 VSA, I/O
Libraries, Command Expert, Signal Studio.
Agilent EDA software: SystemVue
3rd party applications
and development
environments that are
integrated with
Waveform Creator
Microsoft VisualC++,MATLAB, VHDL/
Verilog, FPGA Hardware-in-Loop, (HIL), STK
(Analytical Graphics) and more.
15
89
SYSTEMVUE
Agilent SystemVue
System Level Design & Verification
www.agilent.com/find/systemvue
T y p i c a l A p p l i cat i o ns
• Signal generation with fading & impairments
• Early standards support
• Wideband system validation
P r o d u c t D escr i p t i o n
Agilent SystemVue is a system-level EDA environment
that accelerates design and verification of defense and
communications systems at the physical layer, where
advanced digital signal processing meets RF. SystemVue
brings together baseband algorithm modeling, accurate
RF, trusted Reference IP, and measurement automation
in a single environment for high-performance RF/DSP
co-design.
Agilent SystemVue combines with Agilent Modular
Products to create an expandable platform for modeling,
implementing, and validating next-generation communications systems and defense systems. A modular approach
enables a virtual system to be verified from the first day of
the project - beginning with simulation models and incorporating measurements as the project progresses.
Ordering Information
Recommended Products & Environments
Core Environment
• W1461BP SystemVue Comms Architect
People who use Agilent Modular Instruments often buy:
• W1716EP Digital Pre-Distortion Builder
• W1905EP Radar Model Library
• W1902EP Digital Modem Library
• W1918EP LTE-Advanced Baseband Verification Library
Softw are Information
M a i n F e a tur e s and B e ne fi t s
15
90
Product features
Your benefits
Popular modeling languages: C++,
MATLAB .m, HDL, or graphical
dataflow schematics
Open, vendor-neutral formats
reduce costs and connect Agilent
Test with Enterprise EDA tools
Superior RF simulation speed &
accuracy, with links to RF EDA
Virtualize RF/MIMO components
for earliest system validation with
high confidence
World-class IP references for LTEAdvanced, 802.11ac/ad, Radar,
and other standards
Create and re-use TX/RX and
MIMO verification suites with
confidence across the whole
lifecycle from design to test
Superior integration of Simulation
with Test & Measurement
Bring “Drive Test” accuracy into
4G design, while creating custom
personalities around test
Interoperates with a wide
variety of Agilent equipment and
software, including 89600 VSA
and Command Expert
Makes highest use of best-incategory assets, while unifying
DSP and RF design lifecycles into
a coherent flow
Software operating
systems
Microsoft Windows 8 (32/64-bit)
Microsoft Windows 7 (32/64-bit)
Microsoft Windows XP (32-bit)
Available Addon Applications
and Design Flow
Personalities
Fixed-point models, HDL Code-Generation,
C++ Code Generation, Adaptive EQ, DPD
Builder, MIMO Channel Builder, RF System
Architectures
Available Standards
Reference Libraries
Comms: LTE-Advanced, LTE, HSPA+,
WCDMA, cdma2000® , CDMA, WiMAX™,
802.11a/ac/ad, DVB-S2/T2, Custom OFDM,
Bluetooth, Zigbee, and nearly 40 general
purpose formats for Milcomm/Satcomm.
Radar: Doppler, UWB, SAR, DAR,
FMCW, Phased Array, Beamforming
Agilent software
applications that are
tightly integrated with
SystemVue
Agilent test software: 89600 VSA,
FlexDCA, I/O Libraries, Command Expert,
Waveform Creator.
Agilent EDA software: Advanced Design
System, GoldenGate
3rd party applications
and development
environments that are
integrated with
SystemVue
Microsoft VisualC++,MATLAB, VHDL/
Verilog, FPGA Hardware-in-Loop, (HIL), STK
(Analytical Graphics) and more.
SIGNAL STUDIO
Agilent
Signal Studio Software
www.agilent.com/find/SignalStudio
I n d u s tr i e s and A p p l i cat i o ns
• Cellular communications
Ordering Information 1
Model
Description
N7600B
W-CDMA/HSPA+
N7601B
cdma2000®/1xEV-DO
N7602B
GSM/EDGE/Evo
N7606B
Global Navigation Satelite Systems (GNSS)
N7609B
Bluetooth
Signal Studio is a flexible suite of easy to use signal
creation tools that reduce the time spent on signal creation
and simulation. It offers performance optimized reference
signals validated by Agilent, supporting a wide variety of
communications standards including LTE, W-CDMA, and
WLAN 802.11ac.
N7611B
Broadcast Radio
N7612B
TD-SCDMA/HSPDA
N7615B
Mobile WiMAX™
N7617B
WLAN 802.11a/b/g/n/ac
N7623B
Digital Video
• Create reference signals for mobile communications,
wireless connectivity and digital broadcast standards
N7624B
LTE/LTE-Advanced FDD
N7625B
LTE/LTE-Advanced TDD
• Wireless connectivity
• Audio/video broadcasting
P r o d u c t D e scr i p t i o n
• Create test patterns for advanced detection, positioning, tracking and navigation systems
• Create virtually distortion free test signals for component analysis.
Ma i n F e a tur e s and B e ne fi t s
Product features
Your benefits
Application-specific test signals
at baseband, RF and MW
frequencies
Reduce the time you spend on
signal simulation
Download capability to benchtop
or modular signal generators
Apply your signals in real world
testing
Waveform playback and real-time
modes
Create and customize waveform
files needed to test components
and receivers. Perform advanced
testing with real-time mode.
Signal Studio waveforms can be
programatically initiated with SCPI
commands or through soft front
panels.
Accelerate testing on production
line
1. List of Signal Studio software products which connect to M9381A PXI
VSG. Playback on up to four channels per license
•
N76xxB-9TP transportable perpetual license
•
N76xxB-9FP fixed perpetual license
•
N7650B-2xx provides 5/50 waveform pack licenses
Softw are Information
Software operating
systems
Microsoft Windows 7 (32/64-bit)
Microsoft Windows XP (32-bit)
Agilent software
applications that are
tightly integrated with
Signal Studio
Agilent test software: 89600 VSA, I/O
Libraries, Command Expert, Waveform
Creator.
Agilent EDA software: SystemVue,
GoldenGate
3rd party applications
and development
environments that are
integrated with
Signal Studio
Microsoft VisualC++,MATLAB, FPGA
Hardware-in-Loop, (HIL), STK (Analytical
Graphics) and more.
15
91
M9381A
Agilent M9381A
PXIe Vector Signal Generator
www.agilent.com/find/m9381a
I n d u s tr i e s and A p p l i cat i o ns
• Cellular picocell and femtocell test
• RF component manufacturing test
• Wireless transceiver design validation
• WLAN production test
• Military radio & public safety radio test
P r o d u c t D escr i p t i o n
The Agilent M9381A PXIe vector signal generator provides
frequency coverage from 1 MHz to 6 GHz. The M9381A
accelerates test throughput with with fastune, an exclusive baseband tuning technology innovation, enabling you
to switch amplitude and frequency in less than 10 µs.
The M9381A works seamlessly with the M9391A PXIe
VSA, and Agilent's world class software applications
including Waveform Creator, Signal Studio and SystemVue.
M a i n F e a tur e s and B e ne fi t s
15
Product features
Your benefit
Fast amplitude and frequency
switching speed
Accelerate test throughput
fastune
Reduce test time
Accurate power linearity
Improve ability for servo loop to
converge in fewer steps
License-key based upgrades
without returning modules
Purchase what you need today
and easily upgrade later
Calibrated Core Exchange
Strategy
Fast repair and turnaround time
Chassis slot compatibility: PXIe, PXIe Hybrid
92
Spec ific ations and Charac teristic s
1 MHz to 3.0 GHz or 6.0 GHz
Frequency range
• 240 µs for frequency and amplitude
• 105 µs for amplitude-only changes
fastune switching speed ≤ 10 µs for frequency and amplitude
changes within RF modulation bandwidth
(nominal)
RF switching speed (nom)
Phase noise (typical)
< -122 dBc/Hz (1 GHz, 20 kHz offset)
Output power (at 1 GHz)
+18 dBm across the frequency range
+19 dBm from 1 MHz to 5 GHz
Amplitude accuracy
±0.4 to 1 dB
RF modulation bandwidth
40 MHz (flatness: < ±0.2 dB, typical)
100 MHz (flatness: < ±0.3 dB, typical)
160 MHz (flatness: < ±0.5 dB, typical)
AM, FM, PM, Pulse, Multitone
Modulation
≤-70 dBc ACLR for W-CDMA 64 DPCH
<0.5% EVM for WLAN 160 MHz 802.11ac
Modulation quality
Ordering Information
Model
Description
M9381A
PXIe vector signal generator: 1 MHz to 3 or 6 GHz
Includes: M9301A PXIe synthesizer, M9310A PXIe
source output, M9311A PXIe digital vector modulator
Base Configuration
M9381A-F03
Frequency range: 1 MHz to 3 GHz
M9381A-B04
RF modulation bandwidth: 40 MHz
M9381A-M01
Memory: 32 MSa
M9381A-300
for warranted
specifications
PXIe frequency reference: 10 MHz and 100 MHz
Adds M9300A PXIe frequency reference -M9300A
module can support multiple M9381A instruments
Configurable Options
M9381A-F06
Frequency range: 1 MHz to 6 GHz
M9381A-1EA
High output power
M9381A-UNZ
Fast switching
M9381A-B10
RF modulation bandwidth: 100 MHz
M9381A-B16
RF modulation bandwidth: 160 MHz
M9381A-M05
Memory: 512 MSa
M9381A-M10
Memory: 1024 MSa
M9381A-UNT
Analog modulation
M9380A
Agilent M9380A
PXIe CW Source
www.agilent.com/find/m9380a
I n d u s tr i e s and A p p l i cat i o ns
• Cellular picocell and femtocell test
• RF component manufacturing test
• Wireless transceiver design validation
• WLAN production test
• Military radio & public safety radio test
P r o d u c t D escr i p t i o n
The Agilent M9380A PXIe CW source provides frequency
coverage from 1 MHz to 6.0 GHz. A typical M9380A configuration includes three individual PXIe modules—the
M9310A source output, M9301A synthesizer and M9300A
frequency reference—designed for fast data interfaces and
high-speed automated test systems. Instrument control
is provided through a soft front panel and programmatic
interfaces tuned to your application development
environment of choice.
Ma i n F e a tur e s and B e ne fi t s
Product features
Your benefit
License-key based upgrades
without returning modules
Purchase what you need today
and easily upgrade later
One-step software install and
integrated soft front panel
Reduce startup time
Spec ific ations and Charac teristic s
Hardware
Frequency range
1 MHz to 3.0 GHz or 6.0 GHz
Output power
Phase noise (typical)
+18 dBm across the frequency range
+19 dBm from 1 MHz to 5 GHz
< -122 dBc/Hz (1 GHz, 20 kHz offset )
Amplitude accuracy
±0.4 to 1 dB
Size
3-slot
Ordering Information
Model
Description
M9380A
PXIe CW source: 1 MHz to 3 or 6 GHz
Includes: M9301A PXIe synthesizer, M9310A PXIe
source output
Base Configuration
M9380A-F03
Frequency range: 1 MHz to 3 GHz
M9380A-300
Required for
warranted
specifications
PXIe frequency reference:
10 MHz and 100 MHz
Adds M9300A PXIe frequency reference - M9300A
module can support multiple M9380A instruments
Configurable Options
M9380A-F06
Frequency range: 1 MHz to 6 GHz
M9380A-1EA
High output power
Related Products
M9036A
PXIe embedded controller
18-Slot PXIe chassis
Multiple programmatic
interfaces
Easy integration into test
environments and reduced
development time
M9018A
Calibrated Core Exchange
Strategy
Fast repair and turnaround time
Chassis slot compatibility: PXIe, PXIe Hybrid
15
93
M9300A
Agilent M9300A
PXIe Frequency Reference
www.agilent.com/find/m9300a
I n d u s tr i e s and A p p l i cat i o ns
• Cellular picocell and femtocell test
• RF component manufacturing test
Spec ific ations and Charac teristic s
Hardware
Outputs
• Wireless transceiver design validation
100 MHz Output:
• WLAN production test
• Military radio & public safety radio test
The M9300A PXIe frequency reference is a PXIe compatible compact modular instrument that can be configured as
part of the M9391A PXIe Vector Signal Analyzer, M9381A
PXIe Vector Signal Generator, M9380A CW Source or other
PXI solutions. One M9300A can support multiple modular
instruments.
Ma i n F e a tur e s and B e ne fi t s
Product features
Your benefit
Five 100 MHz outputs
Use a common module with
multiple vector signal generators
Locks to another reference with a
value from 1 to 110 MHz.
Flexible module synchronization
Calibrated Core Exchange
Strategy
Fast repair and turn-around time
Chassis slot compatibility: PXIe, PXIe Hybrid
94
Amplitude
Connectors
Impedance
≥ 10 dBm
5 SMB snap-on
50 Ω, (nominal)
10 MHz Output:
P r o d u c t D escr i p t i o n
15
• Five 100 MHz outputs
• One 10 MHz output
• Internal 10 MHz OCXO timebase
output
Amplitude
Connectors
Impedance
9.5 dBm, (nominal)
1 SMB snap-on
50 Ω, (nominal)
OCXO Output:
Amplitude
Connectors
Impedance
11.5 dBm, (nominal)
1 SMB snap-on
50 Ω, (nominal)
Size
1-slot
Ordering Information
Model
Description
M9300A
PXIe Frequency Reference
Includes:
Software, example programs and
product information on CD
Return to Agilent Warranty—3 Years
Related products
M9381A
PXIe Vector Signal Generator
M9380A
PXIe CW Source
M9018A
18-slot PXIe Chassis
M9036A
PXIe Embedded Controller 1
AXIe MODULAR P RODUCTS
• Chassis and Controllers
• Multi-Channel Digitizers
• Arbitrary Waveform Generators
• Logic Analyzers
• PCI Express® Protocol Analyzers
• HDMI Protocol Analyzers
• MIPI M-PHY and D-PHY Protocal Analyzers
NEW
Agilent U4431A AXIe Protocol Analyzer for
MIPI™ M-PHY Interfaces
Agilent M9703A AXIe Digitizers in the
M9505A 5-slot AXIe Chassis
Agilent M8190A AXIe Arbitrary Waveform
Generator in the M9502A 2-slot AXIe chassis
Chassis
Model
Description
Height
Number of
slots
Type
of slots
Maximum data
bandwidth
System slot
Inut power
Consumption
Power per slot
M9502A
2-slot AXIe
Chassis
2U
2
AXIe 1.0
2 GBps module
to module
ESM module
included
800 VA
200 W
M9505A
5-slot AXIe
Chassis
4U
5
AXIe 1.0
2 GBps module
to module
ESM module
included
1280 VA
200 W
Controllers
Model
Description
Type
# of slots
Processor
RAM
(min/max)
HDD
Maximum data
bandwidth
Cable
interface
Front panel
connections
M9536A
AXIe
Embedded
PC Controller
AXIe 1.0
1-slot
Intel Xeon EP
Quad Core
L5518 at 2.13
GHz
8 GB standard,
16 GB optional
24 GB maximum
2.5” SATA II
SSD 160 GB
2GB/s to AXIe
backplane
N/A
USB (3),
10/100/1000
LAN (2), VGA
(up to 1600x1200),
RS-232
www.agilent.com/find/axie
AX I e MOD UL AR PR OD U CTS
AXIe modular products are designed for high-performance, scalable instrumentation and offer fast data transfers to
the host controller. AXIe’s product portfolio includes:
AXIe MODULES
AX I e MOD UL AR PR OD U CTS
Digitizers
Model
Description
Type
# of slots
Resolution
Number of
channels
Max sample
rate
Bandwidth
Memory depth
On-Board
processing
M9703A
AXIe Digitizer
AXIe 1.0
1-slot
12-bit
8-4
1.6 GS/s 3.2 GS/s
DC - 1 GHz
Up to 4 GB
(256 MSamples/ch)
Four Xilinx
Virtex-6
FPGAs
Arbitrary Waveform Generators (AWG)
Model
Description
Type
# of slots
Resolution
Number of
channels
Bandwidth
per
channel
Modulation
bandwidth
Sampling
rate
Memory
depth
M8190A
AXIe
Arbitrary
Waveform
Generator
AXIe 1.0
2-slot
12-bits up
to 12 GSa/s
14-bits up
to 8 GSa/s
Up to 2
channels
5 GHz
5 GHz
125 MSa/s
to 12 GS/s
2 GSa
Logic Analyzer
Model
Description
Type
# of slots
Number of
channels
Supported Signal
Types
Max state
data rate
Max state
clock
Minimum
State clock
frequency
Minimum
data valid
window
U4154A
AXIe Logic
Analyzer
Module
AXIe 1.0
1-slot
136 (Full
Channel
mode)
Single ended
and differential
2.5 Gb/s on
136 channels
4 Gb/s on 68
channels
2.5 GHz
12.5 MHz
(single edge)
6.25 MHz
(both edges)
100 ps
Protocol Analyzers
Model
Description
Type
# of slots
Protocol
Supported
Bus
Configuration
Speed
Memory
Depth
Trigger
Sequencer
Test Modes
U4301A
PCIe® Gen3
Protocol Analyzer
AXIe 1.0
1-slot
136 (Full
Channel
mode)
x8 lanes per
module
2.5 GT/s
(Gen1) 5.0 GT/s
(Gen2) 8.0 GT/s
(Gen3)
4 GB
4 states
Analyzer
U4421A
MIPI™ D-PHY
Protocol Analyzer/
Exerciser
AXIe 1.0
1-slot
MIPI™
D-PHY DSI
& CSI
1, 2, 4
channels
1.5 Gbps
up to 16 GB
8 states
Analyzer/
Exerciser
U4431A
MIPI™ M-PHY
Protocol Analyzer
AXIe 1.0
1-slot
MIPI™
M-PHY
U4998A
HDMI 1.4b
Analyzer/Generator
AXIe 1.0
1-slot
HDMI 1.4b
up to 16 GB
1 source
1 sink port
3.4 Gbps
4 GB
Analyzer
N/A
Analyzer
Generator
Compliance
Connectivity External PC cards¹
Description
M9045B
PCIe ExpressCard adapter: Gen 1
Type
# of slots
Maximum data
bandwidth
Cable interface
PC host interface
ExpressCard 34
1-slot
250 MB/s
x1 Gen 1 PCIe
x1 Gen 1 PCIe
x 8 Gen 2 PCIe
x 8 Gen 2 PCIe
M9048A
PCIe desktop PC Adapter: Gen 2,
PCIe x 8 or x 16
4 GB/s
Clock Isolation
1-slot
¹ Detailed product information for the connectivity modules is available in section 5 of this catalog.
Driver information
Supported operating systems
Microsoft Windows 7 (32/64-bit), Windows Vista (32/64-bit), Windows XP (32-bit)
Standard compliant drivers
IVI-COM, IVI-C, LabVIEW, MATLAB
Supported application development environments (ADE)
Visual Studio (VB.NET, C#, C/C++), VEE, LabVIEW, LabWindows/CVI, MATLAB
Agilent IO Libraries
Includes: VISA Libraries, Agilent Connection Expert, IO Monitor
M9502A / M9505A
Agilent M9502A
and M9505A AXIe Chassis
www.agilent.com/find/axie-chassis
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations (c ont'd)
• Aerospace and defense, communications
• Electronics, semiconductor test
Input power consumption
P r o d u c t D escr i p t i o n
System module type
The M9502A and M9505A AXIe chassis are fully compatible with the AXIe 1.0 specification. They provide 2 or 5
slots for AXIe instrument modules, and have an embedded
system module that does not take up an instrument slot.
The embedded system module provides Gigabit LAN and
x8 PCIe® interfaces for connecting the chassis to an external controller. To minimize rack space, the instrument
module slots are arranged horizontally. In addition, both
the power supply and fan tray can be removed while the
chassis remains in the rack for maintenance.
M a i n F e a tur e s and B e ne fi t s
Product features
Your benefit
Compact size
2-slot chassis is ideal for
transportable applications, while
5-slot saves rack space
Gen 2 x4 links to module slots and
62 local bus pairs
Enables high-performance
applications
Embedded AXIe system module
System module does not take
up a slot, resulting in a smaller
chassis
High cooling capacity
Provides cooling for highperformance modules
S p e c i f i c a ti o ns and C har act e r i st i cs
System module front
panel connectors
M9502A
M9505A
800 VA
1280 VA
Embedded
X8 Gen 2 PCIe, multiframe in/out, trigger
in/out, clock in/out, and Gbit LAN
Maximum power
dissipation per slot
200 W
Local bus pairs
62 pairs between adjacent slots
Data bandwidth
2 GB/s user slot-to-system slot
4 GB/s system slot-to-host
Ordering Information
Model
Description
M9502A
AXIe chassis: 2-slot with embedded system module
M9505A
AXIe chassis: 5-slot with embedded system module
Opt 900-932
Power cord options
Opt U20
ESM with USB 2.0 includes USB cable
USB port is only supported for a limited set of Agilent AXIe modules. Go
to: www.agilent.com/find/axie-chassisusb for compatibility information
Related products
M9536A
Embedded AXIe PC controller
M9045B
PCIe ExpressCard adaptor: Gen 1
Y1200B
PCIe cable: x1 to x8, 2m
M9048A
PCIe PC adapter
Y1202A
PCIe cable: x8, 2.0m (used with M9048A)
16
Accessories
M9502A
M9505A
Y1225A
Rack mount kit for M9502A
Size
2U
4U
Y1226A
Rack mount kit for M9505A
Number of slots
2
5
Y1223A
AXIe multi-frame cable: 0.5m
Power supply output
voltage, (nominal)
50 VDC
52 VDC
Y1224A
AXIe multi-frame cable: 3m
Y1232A
Soft carry bag for M9502A
Total DC module power
400 W
1000 W
N5650-00080
Single-slot AXIe filler module
97
M9536A
Agilent M9536A
AXIe Embedded PC Controller
www.agilent.com/find/m9536a
I n d u s tr i e s and A p p l i cat i o ns
• Aerospace/defense
Hardware
• Communications
Size
1-slot, AXIe module
• Computation
CPU
Intel Xeon EP L5518 processor at
2.13 GHz
• Electronic test
Storage
Type
Size
• Semiconductor testing
• High-energy physics
P r o d u c t D escr i p t i o n
The Agilent M9536A is an AXIe-compatible, embedded PC
controller which provides a high-performance PCIe® Gen2
link to the AXIe backplane. It is the first AXIe embedded
controller available on the market. The M9536A provides
a powerful, one-slot computer that can be used to build
compact AXIe systems while also integrating easily with
LXI instruments with the built-in Gigabit LAN interface.
M a i n F e a tur e s and B e ne fi t s
16
Spec ific ations and Charac teristic s
2.5” SATA II SSD
160 GB
Memory
8 GB standard, 16 GB optional
24 GB maximum
AXIe PCIe link
configuration
x4, Gen 2
AXIe PCIe data
bandwidth (max)
2GB/s to AXIe backplane
AXIe Ethernet fabric
channel
10/100/1000BASE-T
Front panel
connections
USB (3), 10/100/1000 LAN (2), VGA (up to
1600x1200), RS-232
Ordering Information
Model
Description
M9536A
AXIe embedded PC controller
M9536A-M16
Memory upgrade from 8GB RAM to 16 GB
RAM
Product features
Your benefits
Gen 2 PCIe link to backplane
Faster data transfer rates across
the backplane
M9536A-WE6
Intel Xeon EP Quad Core L5518
processor
Faster system performance for
multi-threaded applications
Microsoft Windows Embedded Standard 7
Operating System (64-bit)
M9505A
5-slot AXIe chassis
16 GB RAM option
Support for large, data-intensive
tasks
Related Products
Preloaded with Agilent I/O libraries
and operating system
Reduced test system
development time
Designed for AXIe systems
Provides choice between
embedded and external
controllers
Solid-state drive (SSD)
98
Improved reliability
M9536A-WE3
Microsoft Windows Embedded Standard 7
Operating System (32-bit)
M9502A
2-slot AXIe chassis
Chassis slot compatibility: AXIe 1.0 secondary hub-slot
(slot #1 in the M9502A and M9505A)
M9703A
Agilent M9703A
High-Speed AXIe Digitizer
www.agilent.com/find/m9703a
I n d u s tr i e s and A p p l i cat i o ns
• Large scale applied physics experiments such as
hydrodynamics or plasma fusion
• Radar and satellite communication applications such as
multi-antenna calibration/test or beam-forming
P r o d u c t D e scr i p t i o n
The M9703A is a revolutionary 8-channel digitizer, able
to capture signals from DC to 2 GHz at 1.6 GS/s with
12-bit resolution. An interleaving capability allows
signal acquisition at 3.2 GS/s on four channels with
the best measurement accuracy. The Agilent M9703A
internal FPGAs can feature an optional real-time digital
downconverter (DDC) allowing tuning and zooming on the
analyzed signal. This allows improving the dynamic range,
extending the capture time, and accelerating measurement
speed for your application. Combine with the Agilent 89600
VSA software for advanced measurement analysis.
M a i n F e a tur e s and B e ne fi t s
Spec ific ations (c ont'd)
Channels
8
Sample rate
-SR1
-SR2
1 GS/s
(2 GS/s when interleaved)
1.6 GS/s
(3.2 GS/s when interleaved)
Input frequency range
(–3 dB bandwidth)
DC to 2 GHz
(non-interleaved mode)
Full scale (FS) range
1V/2V
Spurious-free dynamic range (SFDR)
60 dBc (typical)
Effective number of bits (ENOB)
8.8 bits (typical)
Signal-to-noise ratio (SNR)
57 dB (typical)
DDC analysis bandwidth
300 MHz, then 160 MHz/2N,
N = 0, 1, 2, … 18
Ordering Information
Model
Description
M9703A
AXIe 12-bit Digitizer
M9703A-SR1
1 GS/s sampling rate
M9703A-SR2
1.6 GS/s sampling rate
M9703A-INT
Interleaved channel sampling functionality
Input frequency: DC to 650 MHz
Product features
Your benefit
M9703A-F051
8 channels
(4 if interleaving is enabled)
Easily build large scale acquisition
systems
M9703A-F10
Input frequency: DC to 2 GHz (not interleaved)
DC to 1 GHz (interleaved)
12-bit resolution
High dynamic range at GHz speed
M9703A-M101
1 GB (64 MS/ch) acquisition memory
Up to 3.2 GS/s sampling rate
Digitize wideband very fast signals
M9703A-M20
2 GB (128 MS/ch) acquisition memory
DC to 2 GHz input frequency range
Fast and wide signals capture
M9703A-M40
4 GB (256 MS/ch) acquisition memory
Real-time digital downconverter
Tune and zoom on signals for
reduced test time
M9703A-DDC
Digital down-converter firmware
Up to 4 GB (256 MSamples/ch) onboard memory
Long data acquisition time
S p e c i f i c a ti o ns and C har act e r i st i cs
16
These options are included in the default configuration of the M9703A
Related products
M9502A
2-slot AXIe chassis
M9505A
5-slot AXIe chassis
M9536A
Embedded AXIe controller
Size
1 slot
U1092A
AcqirisMAQS Multichannel Acquisition Software
Resolution
12 bits
89601B
89600 VSA software, transportable license
99
M8190A
Agilent M8190A
Arbitrary Waveform Generator
www.agilent.com/find/m8190a
I n d u s tr i e s and A p p l i cat i o ns
• Aerospace and defense
Hardware
• Radar and satellite testing
Size
2-slot AXIe module
Sample rate
125 MSa/s to 12 GSa/s
Resolution
12 bits up to 12 GSa/s
14 bits up to 8 GSa/s
Analog Bandwidth
5 GHz
Spurious-free-dynamic range
(SFDR)
Up to 80 dBc typical
Harmonic distortion (HD)
Up to -72 dBc typical
Transition times
50 ps (20/80)
Memory depth
2 GSa
Type of output
Single-ended or differential,
DC-coupled
Impedance
50 Ω (nom)
• Wideband signal generation
• Wireless communications
• Consumer and computation
• Education and research
P r o d u c t D e scr i p t i o n
From low-observable systems to high-density communications, testing is more realistic with precision arbitrary
waveform generation. Now you can take reality to the
extreme. An Agilent AWG is the source of greater fidelity,
delivering high resolution and wide bandwidth—simultaneously. This unique combination lets you create signal
scenarios that push your designs to the limit and bring
new insights to your analysis. Get bits and bandwidth—
enhance your reality.
Ma i n F e a tur e s and B e ne fi t s
16
Spec ific ations and Charac teristic s
Ordering Information
Model
Description
M8190A
Product only with required accessories
M8190A-001
M8190A-002
1 channel
2 channel
Product features
Your benefits
M8190A-14B
14 bit, 8 GSa/s
5 GHz analog bandwidth
The modulation bandwidth meets
market requirements today and
tomorrow
M8190A-12G
12 GSa/s, 12 bit
M8190A-02G
2048 MSa per channel
50-ch SPST general purpose switch
14 bit with 8 GSa/s
Best SFDR in the market
M9132A
Switchable between 12 bit, 12
GSa/s and 14 bit and 8 GSa/s
Adopt the application to your
needs
2 GSa memory
Test your application with realistic
scenarios over long periods of
time
Related products
Digial upconversion
Change parameters on the fly
Streaming for download
Modify waveforms while playing
them, for infinite playtime
Chassis compatibility: AXIe
100
M8190A requires 2-slot or 5-slot chassis with PCIe® card adapter & cable
M8192A
Synchronization module for up to 12 M8190A
channels
M9045B
PCIe ExpressCard adaptor
M9048A
PCIe desktop adaptor
M9502A
2-slot AXIe chassis
M9505A
5-slot AXIe chassis
M9536A
AXIe controller
U4154A
Agilent U4154A
4Gb/s AXIe Logic Analyzer
Module
www.agilent.com/find/u4154a
I n d u s tr i e s and A p p l i cat i o ns
• Digital debug and logic analysis
Spec ific ations and Charac teristic s
Hardware
Size
1-slot AXIe module
Number of channels
(multiple modules can be
merged)
136 (full channel mode)
per module
Supported signal types
Single-ended and
differential
P r o d u c t D escr i p t i o n
Max state data rate
2.5 Gb/s on 136 channels
4 Gb/s on 68 channels
The Agilent U4154A AXIe logic analyzer system
combines reliable data capture up to 136 channels with
powerful analysis and validation tools to enable you to
quickly and confidently validate and debug high-speed digital designs operating at speeds up to 4 Gb/s. Confidence
in the state mode captures, and bus-level signal integrity
insight, make the U4154A logic analyzer the ideal tool for
DDR memory measurement and debug work.
Max state clock
2.5 GHz
Minimum state clock frequency
12.5 MHz (single edge)
6.25 MHz (both edges)
Minimum data valid window
100 ps
Minimum eye height
100 mV
Timing sample rate
2.5 GHz (full channel mode)
5 GHz (half channel mode)
Timing zoom sampling rate
12.5 GHz
Max trigger sequence speed
2500 MHz (400ps)
• High Speed DDR memory applications
• Analog to digital converter verification
• High-speed ASIC/FPGA debug and validation
Ma i n F e a tur e s and B e ne fi t s
Ordering Information
Product features
Your benefits
Up to 4 Gb/s state speed
Real time capture on high speed busses
100 ps data valid window
Reliable data capture even with small eye
diagrams
12.5 GHz timing zoom
Get simultaneous state and highresolution timing measurements
Dual sample mode
Sample DDR reads and writes
simultaneously
Achieves highest data rates
200 M sample memory
depth
Debug problems where the cause and
symptoms are separated by several
seconds
U4201A
Logic analyzer probe cable (4 per U4154A)
2.5 Gb/s trigger
sequencer
Enabling accurate and precise triggering—
even on complex burst events
Application SW
tools and Probes
Refer to ordering information in data sheet
5990-7513EN
M9502A /
M9505A
2-slot AXIe chassis
2-slot AXIe chassis
Chassis compatibility: AXIe
Model
Description
U4154A
U4154A-02G
Logic analyzer module
State speed 136-channel, 2.5 Gb/s state
68 channel, 4Gb/s state
(Other State speed option is –01G
136-channel, 1.4 Gb/s state
68 channel, 2.8 Gb/s state)
16M memory (other options: 2M, 4M, 8M, 32M,
64M, 128M, 200M)
101
16
U4301A
Agilent U4301A
PCI Express® 3.0
Protocol Analyzer Module
www.agilent.com/find/u4301a
I n d u s tr i e s and A p p l i cat i o ns
• PCI Express Chipset turn-on, Debug and Validation
Hardware
• Root Complex and End-point Debug and validation
Size
1-slot AXIe module
Number of lanes
x16 single direction lanes per
module or bi-direction up to x8
lanes per module
Memory depth
4 GB per module
(8 GB for x16 lanes)
Supported speeds
2.5 GT/s (Gen1)
5.0 GT/s (Gen2)
8.0 GT/s (Gen3)
Speed detection
Automatic among Gen1, Gen2,
Gen 3
Trigger sequencer states
4 states
P r o d u c t D escr i p t i o n
The U4301A helps test engineers and validation labs
address the challenges of transitioning to PCIe® 3.0 by
addressing the high speeds, new encoding scheme, and
advanced protocol features.
The U4301A protocol analyzer module supports all
PCI Express 3.0 speeds, including 2.5 GT/s and 5.0 GT/s
through PCIe 8 GT/s with x1 through x16 support.
Ma i n F e a tur e s and B e ne fi t s
16
Spec ific ations and Charac teristic s
Ordering Information
Product features
Your benefits
Model
Description
Support for Gen1/Gen2/
Gen3, x1 through x16 link
width
Support all modes of operation and all
generations of PCI Express
U4301A
Analyzer module for PCIe 8Gbps
Trace capture mode with lane
view and triggering
Ensure data visibility even in the face
of significant PHY layer issues
U4301A-A08
or
U4301A-A16
4 GB of capture buffer per
module
Debug problems where the cause and
symptoms are separated by large time
gaps
Analyzer linkwidth x8
or
Analyzer linkwidth x16
(2 modules required for x16 analysis)
U4301A-AN3
Analyzer software license for PCIe 8 Gbps
U4301A-AN2
Analyzer software license for PCIe 5 Gbps
Non-intrusive probing that
leverages ESP technology
Reliable capture even with small eye
diagrams
U4321A-A08
Slot interposer 3.0 for PCIe 8 Gbps x8
Mid-bus, Slot Interposer, and
Flying Lead probe, x1 to x16
support
Variety of probing to meet your
specific needs
U4322A
Mid-bus probe 3.0 for PCIe 8 Gbps
(bi-directional x8)
Chassis compatibility: AXIe
102
Related products
M9502A
2-slot AXIe chassis
M9505A
5-slot AXIe chassis
M9536A
AXIe controller
U4421A
Agilent U4421A
Protocol Analyzer and Exerciser
for MIPI™ D-PHY Interfaces
www.agilent.com/find/dphy_analyzer
I n d u s tr i e s and A p p l i cat i o ns
• Mobile chipset debug and test
• Mobile embedded systems
• MIPI™ D-PHY design protocol test
Spec ific ations and Charac teristic s
Lane Width
Up to 4 lanes
Memory Depth
Up to 16 GB (4GB standard)
Display Protocol
Support
Display Serial Interface (DSI) v1.1
Display Serial Interface (DSI) v1.02.00
Display Serial Interface Version 1.01.00
Display Command Set (DCS) v1.1
Display Command Set (DCS) v1.02.00
Display Command Set v1.01.00
Stereoscopic Display Formats (SDF) v1.0
Camera Serial Interface 2 v1.01.00
Camera Serial Interface 2 v1.00 (CSI-2)
• CSI and DSI prototype debug
• D-PHY camera and display test
P r o d u c t D escr i p t i o n
The U4421A MIPI D-PHY Analyzer/Exerciser for CSI-2 and
DSI provides deep insight into mobile computing designs.
The U4421A MIPI D-PHY Exerciser option for CSI-2 and DSI
provides the record length necessary to stimulate designs
with high-definition images and video that best simulates
traffic from a wide variety of device busses of varying
signal performance.
Ma i n F e a tur e s and B e ne fi t s
Camera Protocol
Support
High speed mode
Low power mode
Max Bit rate
1.5 Gbps data rate
10 Mbps
Min Bit rate
80 Mbps
800 Kbps
Ordering Information
Model
Description
U4421A
Exerciser/analyzer
U4421A-601
Analyzer only
U4421A-602
Exerciser only
U4421A-603
Analyzer/exerciser
U4421A-402
2-lane analysis/stimulus option
Product features
Your benefit
MIPI D-PHY Exerciser
Simulate missing devices in your
design, and test it to the corners
of the specification
U4421A-404
4-lane analysis/stimulus option
MIPI D-PHY protocol analyzer for
DSI and CSI-2 traffic, including
trigger and filters
Deep insight into your mobile
computing designs
U4421A-701
CSI-2 protocol
U4421A-702
DSI protocol
Flexible probing solution
Facilitate reliable capture of high
speed MIPI D-PHY signals
U4421A-703
CSI-2 and DSI protocol
U4421A-M04
4GB memory depth
Image level pattern generation
and analysis
Simulate real world conditions
U4421A-M16
16 GB memory depth
Deep memory
Record and generate long duration
events
U4421A-001
Image extractor (requires option 601 or 603)
U4421A-002
Image inserter (requires option 602)
Change signal data rate
Slew rate and lane timing
Bring the “plug fest” experience
to your bench
Chassis compatibility: AXIe
16
Probing and Accessories
U4201A
Analyzer logic cable (required)
E5381A
Analyzer flying lead adapter
E5405A
Analyzer soft touch adapter
U4422A
Exerciser SMA cable, MIPI D-PHY,13 leads/1.5Gbps
103
U4431A
NEW
Agilent U4431A
Protocol Analyzer
MIPI™ M-PHY Interfaces
www.agilent.com/find/mphy_analyzer
I n d u s tr i e s and A p p l i cat i o ns
Hardware
• High resolution cameras
Minimum Vdiff
100 mV
Input impedance (DC)
•
U4433A + N5426A
•
U4432A
700 Ω, typical
128 Ω, typical
Lane width
Up to 4 with option 414
Clocking architecture
Type 1
Analysis direction
Tx or Rx (both with option 612)
The increasing demand for bandwidth has driven the
expansion of the MIPI™ M-PHY specification, the
backbone of next generation mobile computing designs,
to include 4 lane, 6.0 Gbs options. The U4431A offers
up to 16 GB of analysis memory on each lane, allowing
designers to capture tens of seconds of system traffic,
even at high speeds. The U4431A also offers "raw mode",
a feature that enables viewing of time-correlated 8b/10b
data underlying each protocol.
Lane remapping
User selectable
Lane polarity
User selectable
Multiple blade support
Up to 5 time-corrected blades in one frame
HS modes supported
G1 to G3
PWM modes supported
G0 to G7
Rate series supported
A and B
Symbol lock time
•
Fast (HS-G1)
•
Slow (HS-G2, HS-G3)
1 symbol, typical
< 128 symbols
Supported (with no RSE-PO-TX support)
M a i n F e a tur e s and B e ne fi t s
Auto speed detection and
tracking
Memory
1 GB standard, (4GB & 16 GB, optional)
• High-speed peripherals
• Advanced graphics adapters
• Massive memory buffers
P r o d u c t D e scr i p t i o n
16
Spec ific ations and Charac teristic s
Product features
Your benefit
Up to gear 3 HS data rates, 16 GB
trace depth & 4 data lanes
Power to meet the needs of
today's and tomorrow's designs
Track multiple M-PHY busses from
the PHY to application layer. Raw
mode 8b/10b data views
Deep insight into your complex,
mobile computing designs
Infiniium Oscilloscope integration
Integrate your other instruments
Powerful user interface with
customization of system views
Easily customize the solution to
meet your needs
N-way if/then/else trigger
branching with and/or logic
Sophisticated, powerful triggers
PHY and protocol error triggers,
50 macros, event timers and more
104
Ordering Information
Model
Description
U4431A
Protocol analyzer
Analyzer Probes
U4433A
Probe, ZIF flying leads, MIPI M-PHY (one probe both directions)
U4432A
SMA cable, MIPI, M-PHY (one probe both directions)
N5426A
ZIF tip, 12 GHz InfiniMax - Kit of 10
Chassis compatibility: AXIe
U4998A
Agilent U4998A
HDMI 1.4b Protocol
Analyzer and Generator Module
www.agilent.com/find/u4998a
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations and Charac teristic s
• HDMI Authorized Test Centers (ATCs)
Hardware
• HDMI chipset debug and validation
Size
1-slot AXIe module
• Consumer computer video devices incorporating
HDMI debug and validation
Maximum data rate
3.4 Gbps
Memory depth
4 GB
HDMI 1.4b compliance test
support
Source Tests:
7-16 through 7-19,
7-23 through 7-40
Sink Tests:
8-16, 8-21, 8-23, 8-25*, 8-29,
8-30*, 8,31,
(*with E4887A Signal Generator)
HPD (Hot Plug Detect)
Emulate removal and connection of
HDMI cable between tests
Internal frequency counter
Automatically detects clock frequency
without external equipment
Operating modes
Capture/compliance
Generate/compliance
Passive Monitoring
(pass-through/mirror)
P r o d u c t D e scr i p t i o n
The Agilent U4998A HDMI 1.4b Protocol Audio Video
analyzer and generator module enables you to test your
devices to ensure they are HDMI 1.4b CTS compliant. The
module supports source and sink compliance testing of
video formats, including 4K x 2K, 3D, and deep color, up
to the maximum data rate of 3.4 Gbps. The U4998A also
enables test of legal codes, basic protocol, packet type,
pixel encoding, video format timing, AVI Infoframe, ACR,
audio sample packet jitter, deep color, 3D video format and
more.
Ma i n F e a tur e s and B e ne fi t s
Ordering Information
Model
Description
HDMI 1.4b Protocol Analyzer & Generator
Product features
Your benefits
U4998A
Maximum data rate of
3.4 Gbps
Most complete coverage of HDMI data
rates. Supports 4K x 2K, 3D and deep
color video formats
U4998A-PSV
Passive monitoring (pass through/mirror)
M9502A
HDMI 1.4b capture and
generation with compliance
tests
Gain confidence in obtaining CTS
certification of HDMI source and sink
devices
2-slot AXIe chassis
(Requires either external host PC or
M9536A AXIe embedded PC controller)
Passive monitoring with
pass-through and mirror
capabilities (optional)
Monitor the output of a source device
so you can debug and troubleshoot
source and sink issues.
M9536A
AXIe embedded PC controller
N5998U-DBG
Remote control via COM
commands
Automate your HDMI testing and
remotely control the U4998A using
the COM server embedded in the
application software
Software license. Export HDMI captured data for
further evaluation/analysis
Connect to:
Desktop PC
M9048A
Y1202A
PC adapter Gen2, x8
PCIe® cable: x8, 2.0m
Chassis compatibility: AXIe
Related products
M9045B
Y1200B
16
Laptop PC
PCIe ExpressCard
adaptor: Gen 1
PCIe cable: x4 to x8, 2.0m
105
M9045B
Agilent M9045B
PCIe® ExpressCard Adapter
www.agilent.com/find/m9045b
I n d u s tr i e s and A p p l i cat i o ns
• Aerospace and defense
Hardware
• Communications
Card format
PCIe ExpressCard 34
Dimensions
34 mm (1.34 in) x 110.8 mm (4.36 in)
Number of PC slots
1
Data bandwidth (max)
250 MB/s
Connector
x1 PCIe cable connector
Cable length
Up to a 7-meter passive cable supported
• Electronics test
• Semiconductor testing
P r o d u c t D e scr i p t i o n
The M9045B is a PCIe® interface card that can be used
with an Agilent AXIe chassis, such as the M9502A/5A, or
a PCIe cable interface, such as the M9021A.
This adapter uses the ExpressCard 34 format typically
found in laptop computers. It provides a x1 Gen 1 link to
the computer (One Stop OSS-PCIE-HIB2-EC-x1).
Ma i n F e a tur e s and B e ne fi t s
Product features
Your benefit
ExpressCard format and low power
consumption
Provides a transportable
solution
Standard PCIe over cable
16
Spec ific ations and Charac teristic s
Transparent operation with
application software
106
Allows use with any computer
with PCIe ExpressCard
interfaces
Delivers ease of installation
For more complete specifications and manuals, visit the OSS Web
site: http://www.onestopsystems.com/
This product comes with a one year warranty and can be returned
to either Agilent or OSS for warranty service.
Ordering Information
Model
Description
M9045B
PCIe ExpressCard adapter: Gen 1
Related Products
M9021A
PCIe cable interface: Gen 2, x8
M9502A
2-slot AXIe chassis
M9505A
5-slot AXIe chassis
Accessories
Y1200B
PCIe cable: x1 to x8, 2.0m (used with
M9045B)
M9048A
Agilent M9048A
PCIe® Desktop PC Adapter
www.agilent.com/find/m9048a
I n d u s tr i e s and A p p l i cat i o ns
Spec ific ations and Charac teristic s
• Aerospace and defense
Hardware
• Wireless communications
Card format
PCIe half-card format
(half-height and half-width)
Computer expansion
slot compatibility
x8 and x16, Gen 1, 2, or 3*
Dimensions
55 mm (2.2 in) x 114 mm (4.5 in)
Number of PC slots
1
Data bandwidth (max)
4 GB/s (Gen 2 x8 PC slot)
Connector
x8 PCIe IPASS cable connector
Card indicators
LEDs for link status and transport mode
Power consumption
7 W (typ)
Cable length
Up to 2-meter passive cable
PCI bracket
Includes both low profile and standard
profile brackets
Operating temperature
0 C - 55 C
• Electronics test
• Semiconductor testing
P r o d u c t D escr i p t i o n
The M9048A PCIe® desktop PC adapter provides a highperformance (Gen 2 x8) link between a host PC and PXIe or
AXIe chassis.
The M9048A utilizes a PCIe switch and clock isolation to
provide a high-quality clock source driven down the PCIe
cable to the PXIe or AXIe chassis. As a result, the adapter
always provides the same, high-performance Gen 2 link,
independent of the PC. It can also operate in most Gen 3
PC slots because the PC can train to Gen 2. The adapter
is compatible with desktop or rackmount computers that
have either x8 or x16 PCIe expansion slots (mechanical). It
connects directly to the M9502A/5A AXIe or M9018A PXIe
chassis with a Y1202A PCIe cable.
M a i n F e a tur e s and B e ne fi t s
* The M9048A is designed to be compatible with most Gen 3 PCIe PC
slots, but the PC will train to Gen 2.
O r d er in g I n fo r m a t io n
Model
Description
M9048A
PCIe desktop PC adapter: Gen 2, x8, clock
isolation
Related products
Product features
Your benefit
M9018A
PXIe chassis: 18-slot, 3U, 8GB/s
PC host clock isolation
Provides superior computer
compatibility
M9021A
PCIe cable interface: Gen 2, x8
IDT PCIe switch
Compatibility with PCs that
have Gen 3 PCIe slots
M9045B
PCIe ExpressCard adapter
M9502A
Gen 2 x8 PCIe capability
Enables high-performance applications
AXIe chassis: 2-slot with integrated system
module
Standard PCIe over cable
Connects a PXIe or AXIe chassis to
PCs with expansion slots
M9505A
AXIe chassis: 5-slot with integrated system
module
Transparent operation with
application software
Delivers ease of installation
16
Accessories
Y1202A
PCIe cable: x8, 2.0m
107
PROGRAM M ING ENVIRON M ENT
•
A single entry point - the Agilent IO Libraries Suite - for access to instrument control and programming software of
your choice.
•
Programming assistance through Agilent's Command Expert
•
Access to Agilent's Measurement Science and latest measurement algorithms
Agilent IO Libraries Suite offers fast and easy connection to PXI modular instruments and traditional instruments and
reduces system setup and configuration time to mere minutes.
Agilent's Command Expert provides fast and easy instrument control with combined instrument commands,
documentation, syntax checking and command execution all in one simple interface. Instrument command sets are
available for instruments that use IVI-COM drivers or Standard Commands for Programmable Instrumentation (SCPI).
P RO GR AM MI NG EN V I RO NM EN T
Agilent's modular products benefit from multiple software advantages:
Agilent IO
Libraries Suite 16
www.agilent.com/find/iosuite
I n d u s tr i e s and A p p l i cat i o ns
• Aerospace and defense, wireless communications,
electronic test
• Radar and Wideband Signal Capture
Model
Agilent IO Libraries
Suite 16
Free software download at:
www.agilent.com/find/iosuite
Related Products
Agilent Command
Expert:
P r o d u c t D escr i p t i o n
www.agilent.com/find/commandexpert
The Agilent IO Libraries Suite 16 provides all of the software needed to quickly detect and connect to instruments
of all types and manage the communication between the
PC and chassis and instruments for PXI instruments as
well as GPIB, USB, LAN, RS-232 and VXI.
Supported development environments and supported I/O software
Agilent VISA and Connection Expert support PXI, PXIe, and
PCIe® devices. Instrument drivers and soft front panels
can be updated and launched from Connection Expert. The
PXI Resource Manager will discover and display chassis
and modules. New interfaces and new capabilities continue to be added to the connectivity software to provide
users with an improved connection experience.
M a i n F e a tur e s and B e ne fi t s
17
Ordering Information
Product features
Your benefit
Automatically detects chassis and
instruments connected to the PC.
Simplifies the connection process.
Automatically configures interfaces
after detecting chassis and
instruments.
Accelerates development
process decreasing time to first
measurement.
Compatible with all interfaces:
PXI, GPIB, USB, Ethernet/LAN,
RS-232 and VXI test instruments
from a variety of vendors.
Supports mixed systems and
maintains investments as well as
future changes.
Enables instrument
communication for a variety
of development environments
including Agilent VEE Pro,
MATLAB, NI LabVIEW, Microsoft
Visual Studio and more.
Flexibility for integration into
the development environment of
choice.
Automatic notification of updates.
Be confident that you are using
the latest version of the software
110
VB6
VISA COM, VISA, SICL, Agilent 488, Excel VBA
C/C++, Managed
C++
VISA COM, VISA, Agilent 488
.NET languages (VB.
NET, C#)
VISA COM, VISA, Agilent 488
LabVIEW
VISA, Agilent 488
MATLAB
VISA
Note: Agilent IO Libraries Suite supports VEE Pro program development
with drivers and/or Direct I/O.
Softw are Information
Agilent IO Libraries Suite 16 is a Windows-based software package that can be downloaded for free from the Agilent website.
Supported operating systems
Microsoft Windows XP (32-bit)
Microsoft Windows 8 (32/64-bit)
Microsoft Windows 7 (32/64-bit)
Standard compliant drivers
IVI-COM, IVI-C, LabVIEW, MATLAB
Supported application
development environments
(ADE)
Visual Studio (C/C++, C#, VB.NET),
LabVIEW, LabWindows/CVI, MATLAB,
VEE
Agilent
Command Expert
www.agilent.com/find/commandexpert
I n d u s tr ies a n d A p p l i c a t i o n s
• Aerospace and Defense
• Electronic Test
• Wireless Communications
• Radar and Wideband Signal Capture
• And others….
P r o d u c t D e scr i p t i o n
Agilent’s Command Expert is FREE software that provides
fast and easy instrument control in PC application
environments.
Command Expert combines instrument commands,
documentation, syntax checking and command execution
all in one simple interface. Instrument Command Sets
are available for instruments that use IVI-COM drivers or
Standard Commands for Programmable Instrumentation
(SCPI).
• Find instrument commands
• Access command documentation
• Verify command syntax
• Build instrument command sequences
• Execute instrument command sequences
• Integrate sequences into PC application environments
Main Features and Benefits
Product features
Your benefits
Access all IVI-COM
commands and
documentation in one
interface.
Spend less time searching for
the right command.
Rapid prototyping of
instrument commands within
the interface.
Quickly create the right
sequence to perform the
measurements needed.
Put together sequences
before the hardware is
available.
Save development time by
working Off-Line to build
the commands then test the
results once the hardware is
available.
Integration with Visual
Studio, Excel, VEE,
SystemVue, and LabVIEW.
Save time and minimize
rework with syntax checking
available within the program.
Write the sequence once and
reuse in other programming
environments.
Save time and maximize reuse
of code generated.
Ordering Information
Free Software Download
www.agilent.com/find/commandexpert
Related Products
Agilent IO Libraries
www.agilent.com/find/iosuite
Software Information
Software operating systems
Microsoft Windows 7 (32/64-bit),
Standard compliant drivers
IVI-COM
Supported application
development environments
(ADE)
VisualStudio 2005, 2008, 2010
and above
VEE Pro 9.2.2, LabVIEW 8.2.1 or
above, Excel 2007 or Excel 2010
Agilent IO Libraries
Required
111
17
Agilent N6171A
MATLAB Software
www.agilent.com/find/matlab
I n d u s tr i e s and A p p l i cat i o ns
• Aerospace and defense
Operating systems
Microsoft Windows
• Wireless communications
Instrument interfaces
• Radar and Wideband Signal Generation and Capture
GPIB, LAN, and USB through VISA using
Instrument Control Toolbox
Standard compliant
drivers
Supports IVI-COM, IVI-C, and MATLAB
instrument drivers using Instrument Control
Toolbox
P r o d u c t D e scr i p t i o n
Agilent IO Libraries
Includes VISA Libraries, Agilent Connection
Expert, IO Monitor
MATLAB is a popular software environment and language
used by over 1,000,000 engineers and scientists today.
MATLAB is now available for purchase directly from Agilent
as your application development environment for PXI and
AXIe modular hardware.
MATLAB software extends the capabilities of Agilent
modular hardware enabling you to create GUI-based
applications, create custom measurement routines,
generate arbitrary waveforms and more. Three MATLAB
configurations are available from basic MATLAB
capabilities that allow acquisition and analysis of data to
full support for signal processing, communications, filter
design and automated testing.
M a i n F e a tur e s and B e ne fi t s
17
Softw are Information
Product features
Your benefit
Develop GUI-based applications
in MATLAB for your PXI and AXIe
hardware
Easily execute repetitive data
analysis, verification or test
routines
Create arbitrary or standard
waveforms mathematically (multitones, pulsed radar, multi-carrier,
etc.)
Generate the signals necessary
to operate your device
Interface to your modular and
bench top hardware using GPIB,
LAN, USB, VISA, and through IVI or
MATLAB drivers
Acquire and analyze your
data in a single software
environment
Access MATLAB libraries for
creating filters and to demodulate
signals
Perform the needed data
analysis to successfully test or
verify your device
112
Ordering Information
Model
Description
N6171A
The MATLAB software option from Agilent:
Order the -M01, -M02, or -M03 option
N6171A-M01
Basic configuration includes the MATLAB
software environment and Instrument Control
Toolbox
N6171A-M02
Standard configuration includes the MATLAB
software environment, Instrument Control
Toolbox, Communications System Toolbox
DSP System Toolbox, and Signal Processing
Toolbox
N6171A-M03
Advanced configuration includes the MATLAB
software environment, Instrument Control
Toolbox, Communications System Toolbox
DSP System Toolbox, Signal Processing
Toolbox, and RF Toolbox
TESTED COM P UTER L IST
Overview
This personal computer and controller technical note has
been prepared to provide the system designer with a list of
tested computers that are compatible with Agilent Technologies PXI and AXIe chassis. Both AXIe and PXIe chassis are
compatible with each computer unless otherwise noted. The testing in this guide covers both the PCIe® link and enumeration of the chassis. Compatibility can be impacted by many factors including computer BIOS and signal path within the
computer and cable.
Agilen t Te c h n o l o g i e s m o d u l ar c has s i s tested :
• Agilent M9018A PXIe Chassis
• Agilent M9502A AXIe Chassis
• Agilent M9505A AXIe Chassis
TE S TE D C O MP UTE R LI S T
M9018A PXIe Chassis
M9502A AXIe Chassis
M9505A AXIe Chassis
Per s on a l c o m p u t i n g d e v i c e s tested :
• Laptop PC
• Desktop PC
• Tested rack mount PCs
• Tested PXIe embedded PCs
M9018A PXIe 18-slot chassis
18
M9502A AXIe 2-slot chassis
113
TESTING CONF IGURATIONS
Testing configurations
Agilent M9018A
PXIe chassis
• Tested using cabled PCI Express® link with the M9021A PCIe® cable interface and PXIe embedded
controllers.
• Testing was performed with only a graphics card in its standard slot and Agilent-recommended PCIe host
cable card installed ¹
• Laptop testing utilized the M9045B ExpressCard and Y1200B PCIe cable
• Desktop/rack-mounted PC testing utilized the M9048A PCIe interface and Y1202A PCIe cable
• Tested with Microsoft Windows 7 (32/64 bits)
Agilent M9502A
AXIe chassis
• Tested using: cabled PCI Express link,
• Testing was performed with only a graphics card in its standard slot and Agilent-recommended PCIe host
cable card installed ¹
• Laptop testing utilized the M9045B ExpressCard and Y1200B PCIe cable
• Desktop/rack-mounted PC testing utilized the M9048A PCIe interface and Y1202A PCIe cable
• Tested with Microsoft Windows 7 (32/64 bits)
Agilent M9505A
AXIe chassis
1. Applies to desktop and rackmount computers only. In some cases, the graphics card must also be removed (see computer
comments)
Laptop personal computers 2
Manufacturer
Model
BIOS
PCIe Link
Number of
chassis ³
Comments
Dell Precision
M6700
A08
x1 Gen 1
1
AXIe only in Gen 1 mode
Hewlett Packard
Elite Book 8470P
68ICF Ver F.31
x1 Gen 1
1
Select Gen 1 BIOS
setting for ExpressCard
Hewlett Packard
Elite Book 8570P
68ICF Ver F.31
x1 Gen 1
1
Select Gen 1 BIOS
setting for ExpressCard
Hewlett Packard
Elite Book 8570W
68IAV Ver F.31
x1 Gen 1
1
Select Gen 1 BIOS
setting for ExpressCard
Note: The following models are supported, but have been discontinued by the manufacturer (they may still be available though
distribution channels).
18
Dell
Precision M4600
A.08
x1 Gen 1
1
Dell
Precision M6600
A.07
x1 Gen 1
1
Hewlett Packard
Elite Book 8460P
68SCF Ver F.22
x1 Gen 1
1
Hewlett Packard
Elite Book 8540P
68CVD Ver F.0A
x1 Gen 1
1
Hewlett Packard
Elite Book 8560P
68SCF Ver F.08
x1 Gen 1
1
Select Gen 1 BIOS setting for
ExpressCard
Hewlett Packard
Elite Book 8560W
68SVD Ver. F.26
x1 Gen 1
1
Early models had an
ExpressCard mechanical
compatbility issue
Lenovo
ThinkPad X220
8DET58WW (1.28)
x1 Gen 1
1
Select Gen 1 BIOS setting for
ExpressCard
Lenovo
ThinkPad T420
83ET63WW (1.33)
x1 Gen 1
1
Select Gen 1 BIOS setting for
ExpressCard
Select Gen 1 BIOS
setting for ExpressCard
2. Laptops require the use of ExpressCard® x1 interface cards and therefore will exhibit lower performance than desktop links; however,
the advantage is a thinner cable and added portability.
3. Number of chassis which are supported when connected to the computer.
114
TESTING CONF IGURATIONS ( c on t' d)
Desktop personal computers
Manufacturer
Model
BIOS
PCIe® slots 1
# of
chassis 2
Comments
Acer
Aspire M1
P01-A1
One x16 Gen 2
1
Acer
Aspire M3970
P03-A1
One x16 Gen 2
1
Use GPU slot (remove video card and use
onboard VGA)
Dell Precision
Optiplex 390
A08
One x16 Gen 2
1
Use GPU slot (remove video card and use
onboard VGA)
Dell
T3600
A09
Two x 16 Gen 3
4
Only one slot (M9048A) supported. Move
PERC RAID card to Gen 3 x16 (x4) to install
M9048A. For multiple chassis, set "Bus
Number" field in the BIOS to 256.
Dell
T5600
A09
Two x 16 Gen3
2
Move PERC RAID card to Gen 3 x16 (x4) to
install M9048A. Move GPU to Gen 2 x16 (x4)
slot if second M9048A is required. For multiple
chassis, set "Bus Number" field in BIOS to 256.
Dell
T7600
A07
Two/Four x 16 Gen
4
More than two PCIe® slots requires second
CPU. May have to move RAID and GPU
cards to other slots. For multiple chassis,
set "Bus Number" field in BIOS to 256.
Hewlett Packard
Z420
03.18 Rev A
Two x16 and One x8
Gen 3
2
Only two slots supported the third can be
used for graphics
Hewlett Packard
Z620
03.18 Rev A
Two x16 and One x8
Gen 3
2
Only two slots supported the third can be
used for graphics
Hewlett Packard
Z820
03.16 Rev A
Two/three x16 Gen 3
One x16 (x8) Gen 3
2
Second CPU required for third x16 and x16
(x8) slots.
The following models are supported, but have been discontinued by the manufacturer (may be available though distribution channels).
Dell
T3500
From ftp.
agilent.com
Two x8 (x4) and two
x16 graphics Gen 2
1
Check ftp://ftp.agilent.com/pub/ mpusup/
BIOS for latest information including
supported BIOS versions
Dell
T5500
From ftp.
agilent.com
Two x16 (x8) and two
x16 graphics Gen 2
3
Check ftp://ftp.agilent.com/pub/mpusup/
BIOS for latest information including
supported BIOS versions
Dell
T7500
From ftp.
agilent.com
Two x16 (x8) and two
x16 graphics Gen 2
4
Check ftp://ftp.agilent.com/pub/mpusup/
BIOS for latest information including supported
BIOS versions Move GPU to x16 (x8) slot
Dell
XPS 8300
A06
One x16 graphics
Gen 2
1
M9048A only--use GPU slot (remove video
card and use onboard VGA)
Hewlett Packard
ProLiant M11067 J01
One x16 Gen 2
1
Hewlett Packard
Compaq 8200
01 v.02.09
One x16 Gen 2
1
Hewlett Packard
ML150G6 Server
O21
One x16 Gen 2
1
Hewlett Packard
Z400
3.54 Rev A
Two x16 Gen 2
1
Only one slot supported. The second can be
used for graphics
Lenovo
ThinkStation D20
61KT48AUS
Two x16 Gen 2
1
Only one slot supported. The second can be
used for graphics
Lenovo
ThinkStation S20
60KT44US
Two x16 Gen 2
1
Only one slot supported. The second can be
used for graphics
1. Tested PCIe slots in the PC. There may be additional slots in the PC which are not tested/supported. First number is mechanical
connection, number in parenthesis is electrical connection. For example, x8 (x4) is a x8 slot wired as a x4. PCIe slots without a
second number are the same mechanical/electrical
2. Number of chassis which are supported when connected to the computer. For more information see: www.agilent.com/find/pxiemultichassis. Available slots may depend on graphics used. More than two chassis requires a 64-bit OS
115
18
TESTING CONF IGURATIONS ( c on t' d)
Rackmount personal computers
Manufacturer
Model
SuperLogic
SL-4U-Q67SW-WB
Dell
R5500
Kontron
KISS IPC 760
BIOS
SWQ6710H.86A.0060.
2011.1220.1805
PCIe® Slots 1
Number of
chassis 2
One x16
Gen2
1
I01
Up to two x16
(x8) and three
x16 graphics
Gen2
4
08.00.15
One x16
Gen2
1
Comments
Check ftp://ftp.agilent.com/
pub/mpusup/BIOS
for latest information including
supported versions
1. Tested PCIe slots in the PC. There may be additional slots in the PC which are not tested/supported. First number is mechanical
connection, number in parenthesis is electrical connection. For example, x8 (x4) is a x8 slot wired as a x4. PCIe slots without a
second number are the same mechanical/electrical.
2. Number of chassis which are supported when connected to the computer. For more information see www.agilent.com/find/pxiemultichassis. Available slots may depend on graphics used. More than two chassis requires a 64-bit OS.
PXIe embedded personal computers
Model
BIOS
System Slot
PCIe Links
Number of
chassis 3
Comments
M9036A
AG20 or
AG20-M
4x4 Gen 2 and
2x8 Gen 2
4
No restrictions
National
Instruments
PXIe-8108
4.6.3
4x1 Gen 1
1
No restrictions
National
Instruments
PXIe-8133
4.6.3
4x4 Gen 1
1
No restrictions
National
Instruments
PXIe-8135
1.0.0f4
4x4 or 2x8 Gen 2
1
No restrictions
Manufacturer
Agilent
Note: The following models are supported, but have been discontinued by the manufacturer (they may still be available though
distribution channels).
National
Instruments
PXIe-8101
4.6.3
4x1 Gen 1
1
No restrictions
National
Instruments
PXIe-8105
1.3.3
Four link: 1x1 and
3x4 Gen 1
1
No restrictions
3. Number of chassis which are supported when connected to the computer. More than two chassis requires a 64-bit OS. For more
information see www.agilent.com/find/pxie-multichassis.
AXIe embedded personal computers
Manufacturer
Agilent
18
116
Model
BIOS
System Slot PCIe Links
Comments
M9536A
AG10
AXIe PCIe Link
x4 Gen 2
AXIe slot one only
Be co me a P a rt ner
Agilent’s Solution Partners can create an optimized modular test system for you
Modular products have the inherent power and flexibility to
provide the building blocks for any test system. However,
when time is of the essence and you need a test system
that addresses your measurement needs – and fast –
Agilent has an extensive network of premier partners to
develop systems from Aerospace and Defense to ZigBee.
Agilent’s Solutions Partner Program recruits and supports
mature, stable companies with the complementary skills
to fulfill this role for you. Our Solutions Partners enjoy a
preferential relationship and work closely with Agilent to
develop systems that take advantage of all the measurement capabilities of our instruments. When you tap into
the resources of our partners, you also benefit from this
knowledge and experience.
Partner Value
Become a Partner...
•
Software to control the system and manage test flow
•
Fixturing to interface to the device under test
•
Racking systems to house instrumentation and switching
•
Environmental or anechoic chambers
•
Services to integrate elements into a complete system
•
Training for customers’, operators, and engineers
•
Services to install and support the test system in use
Worldwide, there are already over 200 companies
involved in the Agilent Solutions Partner Program, but
we are always looking for partners who can provide
additional solutions for our customers. If you have the
skills and expertise that can help expand our modular
solutions portfolio, we want to hear from you.
As a first step, simply follow the “Become a Partner”
link at www.agilent.com/find/solutionspartners,
complete and submit the form.
19
www.agilent.com/find/solutionspartners
117
Sp e cific a t i ons D efi ni t i o n s
Specifications describe the warranted performance of calibrated instruments that have been stored for a minimum of two
hours within the operating temperature range of 0 °C to 55 °C, unless otherwise stated, and after a 45 minute warm-up
period. Data represented in this document are specifications unless otherwise noted.
Characteristics describe product performance that is useful in the application of the product, but that is not covered by the
product warranty. Characteristics are often referred to as Typical or Nominal values and represented in italics.
Typical describes characteristic performance, which 80% of instruments will meet when operated over a 20 °C to 30 °C
temperature range. Typical performance is not warranted.
Nominal describes representative performance that is useful in the application of the product when operated over a
20 °C to 30 °C temperature range. Nominal performance is not warranted.
Note: All graphs contain measured data from several units at room temperature unless otherwise noted.
20
118
cu st om er SUP P ORT AND w a r r a n t y i n f o r m a t i o n
Customer Support
For your ease of ordering, the product information pages within this catalog come complete with product descriptions and
model numbers. In addition, the ordering information includes: typical product configuration, typical system configuration,
related products and accessories.
Product Information: www.agilent.com/find/contactus
or call 1 800 829-4444 US
Repair and Calibration: www.agilent.com/find/infoline
Parts and Accessories: www.parts.agilent.com
Email updates: www.agilent.com/find/emailupdate
For all modular products: www.agilent.com/find/modular
Advantage Services: Calibration and Warranty
What is covered by warranty?
Standard 3-year Global Warranty
Warranty Coverage
Agilent Technologies provides the peace-of-mind that
today’s high-tech industry requires. Your investment is protected by Agilent’s global reach in more than 100 countries
(either directly or through distributors). Convenient, the
warranty gives you standard coverage for the country in
which the product is in use, eliminating the need to ship
equipment back to the country of purchase. Agilent warranty services provide:
Agilent warrants Agilent hardware products against
defects in materials and workmanship and that Agilent
hardware products conform to Agilent published specifications. Warranty does not cover visible abuse, negligence
or shipping damage, nor does it apply to defects resulting
from improper or inadequate maintenance or calibration
by Customer or unauthorized parties, Customer-supplied
software, interfacing or supplies, unauthorized modification or improper use of Product, operation outside of the
published environmental specifications for the Product, or
improper site preparation or maintenance by Customer. For
specific operation environment specifications, refer to the
product manual.
• All parts and labor necessary to return your instrument
to full specified performance
• Recalibration for products supplied originally with a
calibration certificate
• Return shipment
Advantage Services: Calibration and Warranty
Agilent Advantage Services is committed to your success throughout
your equipment’s lifetime.
R1282A
Annual calibration
Standard
Return-to-Agilent warranty 3 years
R-51B-001-5C
3 year return-to-Agilent warranty extended to 5 years
20
www.agilent.com/find/advantageservices
119
Index by M ODEL num b e r
21
m o del
descriptio n
Page
Dual Channel System
PXI Dual Channel Vector Signal Analyzer
E2300
Command Expert Software
111
E2094
IO Libraries Suite
110
MIMO System
PXI Wideband MIMO Vector Signal Analyzer
M8190A
AXIe Arbitrary Waveform Generator
M9018A
PXIe Chassis: 18 slot, 3U, 8 GB/s
19
20
76
78
100
M9021A
PCIe Cable Interface: x8
M9036A
PXIe Controller
M9045B
PCIe® Laptop Adapter: x1
22, 106
M9048A
PCIe® Desktop PC Adapter: Gen 2, Clock Isolation
23, 107
M9099
Waveform Creator software
89
M9101A
PXI High Density Multiplexer: 64-ch, 2-wire, 100 Vdc/1 A, Reed Relays
37
M9102A
PXI High Density Multiplexer: 128-ch, 1-wire, 100 Vdc/1 A, Reed Relays
37
M9103A
PXI High Density Multiplexer: 99-ch, 2-wire, 100 Vdc/1 A, EM Relays
37
M9120A
PXI Matrix Switch: 4x34, 2-wire, 100 Vdc/2 A, EM Relays
38
M9121A
PXI Matrix Switch: 4x64, 2-wire, 100 Vdc/.5A, Reed Relays
38
M9122A
PXI Matrix Switch: 8x32, 1-wire, 100 Vdc/2A, EM Relays
38
M9128A
PXI RF Matrix Switch: 300 MHz, 8x12, 50 Ω
39
M9130A
PXI SPDT Switch: 26-ch, 100 Vdc/2 A, EM Relays
40
M9131A
PXI SPDT Switch: 64-ch, 100 Vdc/2 A, Reed Relays
40
M9132A
PXI SPST Switch: 50-ch, 100 Vdc/1 A, Reed Relays
40
M9133A
PXI SPST Switch: 100-ch, 10 Vdc/1 A, Reed Relays
40
M9135A
PXI SPST Power Relay, 20-ch, 10 A @ 250 Vac, 300 W
40
M9146A
PXI RF Multiplexer: 3 GHz, Dual 1x4, 50 Ω, Terminated
39
M9147A
PXI RF Multiplexer: 3 GHz, Dual 1x4, 50 Ω, Terminated Common
39
M9148A
PXI RF Multiplexer: 3 GHz, 1x8, 50 Ω
39
M9149A
PXI RF High Density RF Multiplexer: 3 GHz, Dual 1x16, 50 Ω
39
M9150A
PXI RF Multiplexer: 3 GHz, Dual 1x4, 75 Ω
39
M9151A
PXI RF Multiplexer: 3 GHz, Quad 1x4, 75 Ω
39
M9152A
PXI RF Multiplexer: 3 GHz, 1x8, 75 Ω
39
M9153A
PXI RF Multiplexer: 3 GHz, 1x16, 75 Ω
39
M9155C
PXI Hybrid Dual SPDT Coaxial Switch, DC to 26.5 GHz
41
M9156C
PXI Hybrid Dual Transfer Switch, DC to 26.5 GHz
41
M9157C
PXI Hybrid Single SP6T Switch, DC to 26.5 GHz
41
M9155CH40
PXI Hybrid Dual SPDT Coaxial Switch, DC to 40 GHz
42
M9156CH40
PXI Hybrid Dual Transfer Switch, DC to 40 GHz
42
M9157CH40
PXI Hybrid Single SP6T Switch, DC to 40 GHz
42
M9168C
PXI Programmable Step Attenuator Module
80
M9170A
PXI Attenuator/Switch Driver module
43
M9181A
Basic Features PXI DMM
49
120
®
21
index BY M ODEL NU M BER ( c o n t I NUED)
m o del
descriptio n
M9182A
PXI Digital Multimeter: 6½ digit
50
M9183A
PXI Digital Multimeter: 6½ digit, Enhanced Performance
50
M9185A
PXI 8/16-Channel Isolated D/A Converter
59
M9186A
PXI Isolated Single Channel Voltage/Current Source, 100V
60
M9187A
PXI Digital IO: 32-ch, 0.3 to 50 V
46
M9202A
PXIe IF Digitizer: 12 bit, 1 GHz
M9210A
PXI-H Digitizing Scope: 10-bit, 2-4 GS/s
54
M9211A
PXI-H UWB IF Digitizer: 10-bit, 4 GS/s, 3 GHz
55
M9216A
PXI 32-Channel High Voltage Data Acquisition Module
44
M9252A
PXIe DigRF Host Adapter
66
M9300A
PXIe Frequency Reference
94
M9302A
PXI Local Oscillator: 3 GHz to 10 GHz
82
M9330A
PXI-H Arbitrary Waveform Generator: 15-bit, 1.25 GS/s
63
M9331A
PXI-H Arbitrary Waveform Generator: 10-bit, 1.25 GS/s
64
M9351A
PXI Downconverter: 50 MHz to 2.9 GHz
83
M9352A
PXI Hybrid Amplifier Attenuator
84
M9360A
PXI Attenuator/Preselector: 100 kHz to 26.5 GHz
85
M9361A
PXI Downconverter: 2.75 GHz to 26.5 GHz
86
M9362A-D01
PXIe Quad Downconverter
79
M9380A
PXIe CW Source
93
M9381A
PXIe Vector Signal Generator
92
M9391A
PXIe Vector Signal Analyzer
75
M9392A
PXI Vector Signal Analyzer: 50 MHz to 26.5 GHz
77
M9403A
PXIe Optical Transmitter: 300 kHz to 26.5 GHz or 50 GHz
68
M9404A
PXIe Optical Receiver: 300 kHz to 26.5 GHz or 50 GHz
68
M9405A
PXIe Optical Amplifier: 300 kHz to 26.5 GHz or 50 GH
68
M9406A
PXIe Optical to USB 2.0
68
M9407A
PXIe Optical to 4 Port USB 2.0 Hub
68
M9408A
PXIe Remote RF Reflectometer
68
M9502A
AXIe 2-slot Chassis
97
M9505A
AXIe 5-slot Chassis
97
M9536A
AXIe Embedded PC Controller
98
M9703A
AXIe Digitizer 12-bit, 8 Channels
99
N2099A
PXI RF Synthesizer
27
N2100B
PXI Digital Communication Analyzer
28
N2101B
PXI Bit Error Rate Tester
29
N2102B
PXI Pattern Generator
30
U4154A
AXIe Logic Analyzer 4 Gb/s
101
U4301A
AXIe Protocol Analyzer PCI Express® 3.0
102
U4421A
AXIe Protocol Analyzer and Exerciser for MIPI™ D-PHY Interfaces
103
U4431A
AXIe Protocol Analyzer for MIPI™ M-PHY Interfaces
104
U4998A
AXIe Protocol Analyzer HDMI 1.4b
105
89601B
89600 VSA software, transportable license
N6171A
Matlab software
Signal Studio
Signal Studio software
W1461BP
SystemVue Software
X-Series
X-Series Measurement Applications for Modular Instruments
Page
53, 81
73
112
91
74, 90
72
121
21
Index by p roduc t des c r ip t i o n
pr o duct descriptio n
model
21
Page
Adaptor (PCIe desktop PC Adapter: Gen 2, Clock Isolation)
M9048A
23, 107
Adaptor (PCIe Laptop Adaptor: x1)
M9045B
22, 106
Amplifier/Attenuator (PXI Hybrid)
M9352A
84
Attenuator (PXI Programmable Step Attenuator Module)
M9168C
80
Attenuator/Preselector (PXI 100 kHz to 26.5 GHz (PXI)
M9360A
85
Attenuator (PXI Switch Driver module)
M9170A
43
AWG (AXIe Arbitrary Waveform Generator)
M8190A
100
AWG (PXI-H Arbitrary Waveform Generator: 10-bit, 1.25 GS/s)
M9331A
64
AWG (PXI-H Arbitrary Waveform Generator: 15-bit, 1.25 GS/s)
M9330A
63
Bit Error Rate Tester (PXI)
N2101B
29
Chassis (AXIe 5-slot)
M9505A
97
Chassis (AXIe 2-slot)
M9502A
97
Chassis (PXIe Chassis: 18-slot, 3U, 8 GB/s)
M9018A
19
Controller (AXIe Embedded PC)
M9536A
98
Controller (PXIe)
M9036A
21
D/A Converter (PXI 8/16-Channel Isolated)
M9185A
59
Data Acquisition Module (PXI 32-Channel High Voltage)
M9216A
44
DCA (PXI Digital Communication Analyzer)
N2100B
28
Digital IO (PXI: 32-ch, 0.3 to 50 V)
M9187A
46
Digitizer (AXIe 12-bit, 8 Channels)
M9703A
99
Digitizer (PXIe IF Digitizer: 12-bit, 1 GHz)
M9202A
53, 81
Digitizer (PXI-H UWB IF Digitizer: 10-bit, 4 GS/s, 3 GHz)
M9211A
55
DigRF Host Adapter
M9252A
66
DMM (PXI Digital Multimeter: 6½ digit)
M9182A
50
DMM (PXI Digital Multimeter: 6½ digit, Enhanced Performance)
M9183A
50
DMM (PXI)
M9181A
49
Downconverter: 2.75 GHz to 26.5 GHz (PXI)
M9361A
86
Downconverter: 50 MHz to 2.9 GHz (PXI)
M9351A
83
Frequency Reference (PXIe Frequency Reference)
M9300A
94
IO Libraries Suite
E2094
LO (PXI Local Oscillator: 3 GHz to 10 GHz)
M9302A
82
Logic Analyzer 4 Gb/s (AXIe)
U4154A
101
Matlab software
N6171A
112
Multiplexer (PXI High Density : 128-ch, 1-wire, 100 Vdc/1 A, Reed Relays)
M9102A
37
Multiplexer (PXI High Density : 64-ch, 2-wire, 100 Vdc/1 A, Reed Relays)
M9101A
37
Multiplexer (PXI High Density : 99-ch, 2-wire, 100 Vdc/1 A, EM Relays)
M9103A
37
Multiplexer (PXI RF Multiplexer: 3 GHz, 1x16, 75 Ω)
M9153A
39
Multiplexer (PXI RF Multiplexer: 3 GHz, 1x8, 50 Ω)
M9148A
39
Multiplexer (PXI RF Multiplexer: 3 GHz, 1x8, 75 Ω
M9152A
39
Multiplexer (PXI RF Multiplexer: 3 GHz, Dual 1x4, 50 Ω, Terminated Common)
M9147A
39
Multiplexer (PXI RF Multiplexer: 3 GHz, Dual 1x4, 50 Ω, Terminated)
M9146A
39
Multiplexer (PXI RF Multiplexer: 3 GHz, Dual 1x4, 75 Ω)
M9150A
39
Multiplexer (PXI RF Multiplexer: 3 GHz, Quad 1x4, 75 Ω)
M9151A
39
®
122
110
index BY P RODUCT DESCR I P T I ON ( c o n t I NUED)
pr o duct descriptio n
model
Page
Optical Amplifier (PXIe 300 kHz to 26.5 GHz or 50 GH)
M9405A
68
Optical Receiver (PXIe 300 kHz to 26.5 GHz or 50 GHz)
M9404A
68
Optical Reflectometer (PXIe Remote RF)
M9408A
68
Optical Transmitter (PXI 300 kHz to 26.5 GHz or 50 GHz)
M9403A
68
Optical USB (PXIe USB 2.0)
M9406A
68
Optical USB ( PXIe 4 Port USB 2.0 Hub)
M9407A
68
Pattern Generator (PXI)
N2102B
30
Power Relay (PXI SPST Power Relay, 20-ch, 10 A @ 250 Vac, 300 W)
M9135A
40
Protocol Analyzer HDMI 1.4 (AXIe)
U4998A
105
Protocol Analyzer (AXIe Analyzer Exerciser for MIPI™ D-PHY Interfaces)
U4421A
103
Protocol Analyzer (AXIe Analyzer for MIPI™ M-PHY Interfaces)
U4431A
104
Protocol Analyzer PCI Express® 3.0 (AXIe)
U4301A
102
PXI-H Digitizing Scope: 10-bit, 2-4 GS/s
M9210A
54
Quad Downconverter (PXIe)
M9362A-D01
79
RF Multiplexer (PXI RF High Density RF Multiplexer: 3 GHz, Dual 1x16, 50 Ω)
M9149A
39
RF Synthesizer (PXI)
N2099A
Software (Command Expert)
E2300
Software (Signal Studio)
Signal Studio
Software (SystemVue)
W1461BP
Software (X-Series Measurement Applications for Modular Instruments)
X-Series
72
Software (Waveform Creator)
M9099
89
Software (89600 VSA)
89601B
73
Source (PXIe CW Source)
M9380A
93
Switch (PXI Hybrid Dual SPDT Coaxial Switch, DC to 26.5 GHz)
M9155C
41
Switch (PXI Hybrid Dual Transfer Switch, DC to 26.5 GHz)
M9156C
41
Switch (PXI Hybrid Single SP6T Switch, DC to 26.5 GHz)
M9157C
41
Switch (PXI Hybrid Dual SPDT Coaxial Switch, DC to 40 GHz)
M9155CH40
42
Switch (PXI Hybrid Dual Transfer Switch, DC to 40 GHz)
M9156CH40
42
Switch (PXI Hybrid Single SP6T Switch, DC to 40 GHz)
M9157CH40
42
Switch (PXI Matrix Switch: 4x34, 2-wire, 100 Vdc/2 A, EM Relays)
M9120A
38
Switch (PXI Matrix Switch: 4x64, 2-wire, 100 Vdc/.5A, Reed Relays)
M9121A
38
Switch (PXI Matrix Switch: 8x32, 1-wire, 100 Vdc/2A, EM Relays)
M9122A
38
Switch (PXI RF Matrix Switch: 300 MHz, 8x12, 50 Ω)
M9128A
39
Switch (PXI SPDT Switch: 26-ch, 100 Vdc/2 A, EM Relays)
M9130A
40
Switch (PXI SPDT Switch: 64-ch, 100 Vdc/2 A, Reed Relays)
M9131A
40
Switch (PXI SPST Switch: 100-ch, 10 Vdc/1 A, Reed Relays)
M9133A
40
27
111
91
74, 90
Switch (PXI SPST Switch: 50-ch, 100 Vdc/1 A, Reed Relays)
M9132A
40
System Interface x8 (PCIe® cable interface)
M9021A
20
VI Source (PXI Isolated Single Channel Voltage/Current Source, 100 V)
M9186A
60
Vector Signal Analyzer (PXI Dual Channel)
Dual Channel
76
Vector Signal Analyzer (PXI Vector Signal Analyzer: 50 MHz to 26.5 GHz)
M9392A
77
Vector Signal Analyzer (PXI Wideband MIMO)
MIMO System
78
Vector Signal Analyzer (PXIe)
M9391A
75
Vector Signal Generator (PXIe)
M9381A
92
21
www.agilent.com/find/modular
123
T h e Mo d u l a r Tang r am
www.agilent.com
The four-sided geometric symbol that appears in this document is called a tangram. The goal of this seven-piece puzzle
is to create identifiable shapes—from simple to complex.
As with a tangram, the possibilities may seem infinite as
you begin to create a new test system. With a set of clearly
defined elements—hardware, software—Agilent can help
you create the system you need, from simple to complex.
www.agilent.com/find/modular
Challenge the Boundaries of Test
Agilent Modular Products
www.pxisa.org
www.axiestandard.org
myAgilent
myAgilent
www.agilent.com/find/myagilent
Agilent Advantage Services
www.agilent.com/find/advantageservices
Three-Year Warranty
www.agilent.com/find/ThreeYearWarranty
www.agilent.com/quality
Agilent Solutions Partners
www.agilent.com/find/solutionspartners
PICMG and the PICMG logo, CompactPCI and the CompactPCI logo,
AdvancedTCA and the AdvancedTCA logo are US registered trademarks
of the PCI Industrial Computers Manufacturers Group. “PCIe” and “PCI
EXPRESS” are registered trademarks and/or service marks of PCI-SIG. MIPI™
is a licensed trademark of MIPI, Inc. in the U.S. and other jurisdictions.
cdma2000 is a registered certification mark of the Telecommunications
Industry Association. Used under license. WiMAX™ is a trademark of the
WiMAX Forum®.
For more information on Agilent Technologies’ products,
applications or services, please contact your local Agilent office.
The complete list is available at: www.agilent.com/find/contactus
Americas
Canada
Brazil Mexico
United States
(877) 894 4414
(11) 4197 3500
01800 5064 800
(800) 829 4444
Asia Pacific
Australia China
Hong Kong India Japan
Korea
Malaysia Singapore Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 375 8100
Europe & Middle East
Belgium 32 (0) 2 404 93 40
Denmark
45 70 13 15 15
Finland
358 (0) 10 855 2100
France
0825 010 700*
*0.125 €/minute
Germany
49 (0) 7031 464 6333
Ireland
1890 924 204
Israel972-3-9288-504/544
Italy
39 02 92 60 8484
Netherlands
31 (0) 20 547 2111
Spain
34 (91) 631 3300
Sweden
0200-88 22 55
United Kingdom
44 (0) 118 9276201
For other unlisted Countries:
www.agilent.com/find/contactus
(BP-3-1-13)
Product specifications and descriptions in this document subject
to change without notice.
© Agilent Technologies, Inc. 2013
Printed in USA, September 3, 2013
5990-7367EN
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising