Imove 250sw

Imove 250sw
IM-250SW
User Guide
Innovation , Quality , Performance
Please read these instructions carefully before use
1-
TABLE OF CONTENTS
1.Safety Instruction
2.Technical Specification
3.Lamp
4.How To Set The Unit
4.1 Control Panel
4.2 Main Function
4.3 Home Position Adjustment
5.How To Control The Unit
5.1 Master/Slave Built-In Preprogrammed Function
5.2 Easy Controller
5.3 DMX Controller
5.4 DMX 512 Configuration
5.5 DMX 512 Connection
6.Troubleshooting
7.Maintenance and Cleaning
2-
1. Safety Instruction
Please read carefully the instruction, which includes important
information about the installation, usage and maintenance.
WARNING
z
Please keep this User Guide for future consultation. If you sell the unit to another user,
be sure that they also receive this instruction booklet.
z
Unpack and check carefully there is no transportation damage before using the unit.
z
Before operating, ensure that the voltage and frequency of power supply match the
EC Declaration of Conformity
power requirements of the unit.
z
It’s important to ground the yellow/green conductor to earth in order to avoid electric
shock.
z
The unit is for indoor use only. Use only in a dry location.
z
The unit must be installed in a location with adequate ventilation, at least 50cm from
adjacent surfaces. Be sure that no ventilation slots are blocked.
z
Disconnect main power before fuse/lamp replacement or servicing.
z
Replace fuse/lamp only with the same type.
z
Make sure there are no flammable materials close to the unit while operating, as it is fire
hazard.
z
Use safety chain when fixes this unit. Don’t handle the unit by taking its head only, but
We declare that our products (lighting equipments) comply with the following
specification and bears CE mark in accordance with the provision of the
Electromagnetic Compatibility (EMC) Directive 89/336/EEC.
EN 55103-1:1996, EN 55103-2:1996, EN 61000-3-2:2006,
EN 61000-3-3:1995+A1:2001+A2:2005
&
Harmonized Standard
always by taking its base.
z
Maximum ambient temperature is Ta : 40℃. Don’t operate it where the temperature is
higher than this.
z
EN 60598-2-17:1989+A2:1991, EN 60598-1:2008
EN62471:2008
Unit surface temperature may reach up to 85℃. Don’t touch the housing bare-hand
during its operation, and allow about 15 minutes to cool down before replacing bulb or
Part 1:General requirements and test
serving, as the unit could be very hot.
z
In the event of serious operating problem, stop using the unit immediately. Never try to
repair the unit by yourself. Repairs carried out by unskilled people can lead to damage
or malfunction. Please contact the nearest authorized technical assistance center.
Always use the same type spare parts.
z
Don’t connect the device to any dimmer pack.
z
Do not touch any wire during operation as there might be a hazard of electric shock.
3-
Following the provisions of the low voltage directive 73/23/EEC and 93/68/EEC
Warning
7. Maintenance and Cleaning
z
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
moisture.
Maintenance:
z
Never touch bulb with bare fingers, as it is very hot after using.
z
Hot lamp explosion hazard. Do not open the unit within five minutes after switching off.
z
Do not start on the unit without bulb enclosure or when housing is damaged.
z
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
damaged.
z
Anti-interference plate
Ignitor
Do not look directly at the light while the bulb is on.
Caution
There are no user serviceable parts inside the unit. Do not open the housing or attempt any
repairs by yourself. In the unlikely event your unit may require service, please contact your
nearest dealer.
Installation
The unit should be mounted via its screw holes on the bracket (please refer to the drawing
Ballast
below). Always ensure that the unit is firmly fixed to avoid vibration and slipping while
A. As the pictures shown above, if the cable or cable joints turned yellow or black, please
replace the cable or cable joints immediately.
B. Do maintain the fixtures every two months and make sure that all the screws and
terminals have been locked firmly to make sure the normal performance of the fixtures.
Negligence of maintenance would cause malfunction of the fixture.
operating. Always ensure that the structure to which you are attaching the unit is secure and
is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable
that can hold 12 times of the weight of the unit when installing the fixture.
The equipment must be fixed by professionals. And it must be fixed at a place where is out
of the touch of people and has no one pass by or under it.
Cleaning:
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimize light output. Cleaning frequency depends on the environment in
which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater
accumulation of dirt on the unit’s optics.
y Clean with soft cloth using normal glass cleaning fluid.
y Always dry the parts carefully.
y Clean the external optics at least every 20 days. Clean the internal optics at least every
30/60 days.
23-
4-
2. Technical Specification
Pay attention to the belt tension when install the belt.
Power supply
- AC 120V~60Hz or AC 230/240/250V~50/60Hz
Please refer to the photos below:
Light Source
- MSD 250W/ NSD 250/2 W
- LED: Total 12pcs, Red: 4pcs, Green: 4pcs, Blue: 4pcs
Optical system
- High efficiency optical system
- High quality optical lens and dichroic colors
- Beam angle: 13°
Shutter/Dimmer
- Blackout, 0~100 smooth dimming and strobe speed variable(1~10 flashes per
second).
Color wheel
- Independent color wheel with 9 trapezoid dichroic colors plus white.
- Color wheel rotates with variable speed, giving rainbow effect.
Gobo wheel
- Independent gobo wheel with 7 rotating, interchangeable gobos plus open: 5 metal
gobos, 2 glass gobos are included.
- Gobo wheel rotates with variable speed, giving shaking effect.
Photo 1
Effect Wheel
- Prism/Rotating Prism
Movement
- Pan: 540° in 2.8 second.
- Tilt: 270° in 1.6 second.
DMX Channels
Channel 1 = Pan
Channel 12 = Prism Rotation
Channel 2 = Tilt
Channel 13 = Focus
Channel 3 = Pan/Tilt Speed selection
Channel 14 = Pan 16 bit
Channel 4 = Dimmer
Channel 15 = Tilt 16 bit
Channel 5 = Shutter/Shaking
Channel 16 = Reset/Lamp on/off
Channel 6 = Color
Channel 17 = Red LED
Channel 7 = No Function
Channel 18 = Green LED
Channel 8 = No Function
Channel 19 = Blue LED
Channel 9 = Gobo
Channel 20 = LED Color Macro
Channel 10 = Gobo Rotation
Channel 21 = Dimmer/Strobe
Channel 11 = Prism
Photo 2
5-
22-
Luminous intensity:
F. If The tilt belt is broken
1. Turn off the main power.
2. Unscrew all the screws (A) and open the right arm cover (B).
3. Unscrew the screws (C), the screws (D) and screws (E) that fix the bridge.
4. Change a new belt (F). Please adjust the tension of the belt properly. Note: do not fix
Dimension: 428 x 369 x 466 mm (L x W x H)
belt too tight as it is easy to rupture.
5. Reverse the procedures from point 3 to 2.
Weight: 23 kg
2.1. Inserting/Exchanging rotating gobos
DANGER!
Install the gobos with the device switched off only.
Unplug from mains before changing gobos!
Open the cover by loosening the fastening screw at the sides of the cover.
If you wish to use other forms and patterns as the standard-gobos, or if the gobos are to be
exchanged, remove the fixation ring with an appropriate tool. Remove the gobo and insert
the new gobo. Press the fixation-ring together and insert it in the front of the gobo.
21-
6-
CAUTION!
Never unscrew the screws of the rotating gobo as the ball bearing
will otherwise be opened!
G. If The pan belt is broken
1. Turn off the main power.
2. Unscrew all the screws (A) and open the base-housing cover (B).
3. Unscrew all the screws (C) and open the arm cover (D).
4. Unplug all the connect wires that from the arm to the bottom.
3. Lamp
5. Unscrew the screws (E) and remove the fixture head.
In case of replacement of the lamp or maintenance, do not open the
fixture within 15 minutes until the unit cools down after switching off.
WARNING
Because of its high internal pressure, there might be a risk that the Discharge lamp
would explode during operation. The lamp emits intense UV radiation which is harmful
6. Loose the screws (F), then loose the screws (G).
7. Change a new belt (H) , put the belt around the axis gear and motor gear.
8. Screwed the screws (G), install the new belt and adjust the belt tension properly. Note: do
not fix belt too tight as it is easy to rupture.
to the eyes and skin. The high luminance of the arc can cause severe damage to the
9. Plug all the connect wires back that form the bottom to the arm.
retina if looks directly at the lamp.
10. Reverse the procedures from point 5 to point 2.
MSD 250W/ NSD 250/2 W
1. Always switch off the main supply and never
handle the lamp or luminaire when it is hot.
2. Do not touch the bulb with bare hands. If this
happens, clean the lamp with denatured
alcohol and wipe it with a lint free cloth
before installation.
3. The lamp generates UV radiation. Never
operate the lamp without appropriate shielding.
4. When burning, the lamp operates at high
pressure and there is a slight risk of arc tube rupture. The risk increases with age,
temperature and improper handling of the lamp. Do not use the lamp any longer than its
specified life.
5. Make sure the lamp is located in the center of the reflector for the best spot.
7-
20-
6. Troubleshooting
4. How To Set The Unit
Following are a few common problems that may occur during operation. Here are
some suggestions for easy troubleshooting:
4.1. Control Panel
A. The unit does not work, no light and the fan does not work
1.
Check the connect power and main fuse.
2.
Measure the mains voltage on the main connector.
3.
Check the power on LED.
B. Not responding to DMX controller
1.
DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
2.
If the DMX LED is on and no response to the channel, check the address settings and
DMX polarity.
3.
If you have intermittent DMX signal problems, check the pins on connectors or on PCB of
the unit or the previous one.
Display
4.
Try to use another DMX controller.
To show the various menus and the selected functions
5.
Check to see if the DMX cables run near or run alongside to high voltage cables that may
LED
cause damage or interference to DMX interface circuit.
C. Some units don’t respond to the easy controller
1. You may have a break in the DMX cabling. Check the LED for the response of the master/
slave mode signal.
2. Wrong DMX address in the unit. Set the proper address.
DMX
On
DMX input present
MASTER
On
Master mode
SLAVE
On
Slave mode
SOUND
Flashing
Sound activation
MENU
To select the programming functions
Button
D. No response to the sound
DOWN
To go backward in the selected functions
1.
Make sure the unit is not receiving DMX signal.
UP
To go forward in the selected functions
2.
Check microphone to see if it is good by tapping the microphone.
ENTER
To confirm the selected functions
E. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is broken.
2. The motor’s drive IC on the PCB might be out of condition.
Remote controller input
By connecting to CA-8 to control the unit for Stand by, Function, and Mode function.
Sensitivity
F. The lamp is cutting out intermittently
1. The lamp is not working well. Check the main voltage either too high or too low.
2. Internal temperature may be too high. Check and if necessary replace the fan on the
To adjust the sound-input sensitivity
DMX input/output
For DMX512 operation, use 3-pin XLR plug cable to link the unit together.
head.
19-
8-
4.2. Main Function
5.5. DMX512 Connection
To select any of the pre-set functions, press the MENU button up to when the required one
is shown on the display. Select the function by ENTER button and the display will blink. Use
DOWN and UP button to change the mode. Once the required mode has been selected,
The DMX512 is widely used in intelligent lighting control, with a maximum of 512
channels.
press the ENTER button to setup or it will automatically return to the main functions without
any change after idling 8 seconds. To go back to the functions without any change press the
MENU button. The main functions are shown below:
1.
If you use a controller with 5 pins DMX connector, you need to use a 5 to 3 pin adapter.
2.
At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm
1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it
in the DMX-output of the last unit.
3.
Connect the unit together in a “daisy chain” by XLR plug cable from the output of the
unit to the input of the next unit. The cable cannot be branched or split to a “Y” cable.
DMX512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or
corroded connectors can easily distort the signal and shut down the system.
4.
DMX512 Address Setting
The DMX output and input connectors are pass-through to maintain the DMX circuit,
when power is disconnected to the unit.
Press the MENU button up to when the
is shown on the display. Pressing ENTER
5.
button and the display will blink. Use DOWN and UP button to change the DMX512 address.
Once the address has been selected, press the ENTER button to setup. Idling 8 seconds
automatically exit menu mode. Back to the functions without any change press MENU
button.
Each lighting unit needs to have an address set to receive the data sent by the
controller. The address number is between 0-511 (usually 0 & 1 are equal to 1).
6.
The end of the DMX512 system should be terminated to reduce signal errors.
7.
3 pin XLR connectors are more popular than 5 pins XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
9-
18-
Show Mode
Press the MENU button up to when the
is showing on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the
(show 1) or
(show 2) or
(show 3) or
(show 4) mode. Once the
mode has been selected, press the ENTER button to setup. Idling 8 seconds automatically
exit menu mode. Back to the functions without any change press MENU button.
Show 1 mode - Fixture is placed on the floor. Tilt movement angle 210°.
Show 2 mode - Fixture is fixed under ceiling. Tilt movement angle 90°.
Show 3 mode - Fixture is placed on the speaker, The spot is always projecting
to the audience’s direction; i.e in front of the stage. Pan movement angle ( left to
right to left ): 160°. Tilt movement angle:
90° ( 60° above horizon; 30° below
horizon).
Show 4 mode - Fixture is fixed under ceiling. The spot is mainly projecting in
front of the stage. Pan movement angle (left to right to left) :160°.
Tilt
movement angle: 90° ( vertically, front 75°; back 15° ) .
Slave Mode
Press the MENU button up to when the
i.) For DMX reset, put DMX value of CH-8 & CH-16 to 255, the unit will reset after about five
seconds.
is shown on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the
or
(normal)
(2 light show) mode. Once the mode has been selected, press the ENTER
For lamp on, put DMX value of CH-8 to 247 & CH-16 to 255.
button to setup. Idling 8 seconds automatically exit menu mode. Back to the functions
For lamp off, put DMX value of CH-8 to 239 & CH-16 to 255.
without any change press MENU button.
ii.) For color sound activated, put DMX value of CH-6 to 248-255.
Blackout Mode
For gobo sound activated, put DMX value of CH-9 to 248-255.
is shown on the display. Pressing ENTER
Press the MENU button up to when the
button and the display will blink. Use DOWN and UP button to select the
blackout) or
(yes
(no blackout) mode. Once the mode has been selected, press the
ENTER button to setup. Idling 8 seconds automatically exit menu mode. Back to the
functions without any change press MENU button.
Pan Inversion
Press the MENU button up to when the
17-
is shown on the display. Pressing ENTER
10-
(normal)
Once the address has been selected, press and keep ENTER button pressed up to when
(pan inversion) mode. Once the mode has been selected, press the ENTER
the display stops blinking or storing automatically 8 seconds later. To go back to the
button and the display will blink. Use DOWN and UP button to select the
or
button to setup. Idling 8 seconds automatically exit menu mode. Back to the functions
functions without any change press the MENU button again.
without any change press MENU button.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
Tilt Inversion
Press the MENU button up to when the
is shown on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the
or
(normal)
5.4. DMX 512 Configuration
(tilt inversion) mode. Once the mode has been selected, press the ENTER
button to setup. Idling 8 seconds automatically exit menu mode. Back to the functions
without any change press MENU button.
Led Display
Press the MENU button up to when the
is showing on the display. Pressing
ENTER button and the display will blink. Use DOWN and UP button to select the
(Led on) or
(Led off) mode. Once the mode has been selected, press the ENTER
button to setup. Idling 8 seconds automatically exit menu mode. Back to the functions
without any change press MENU button.
White Balance
Press the MENU button up to when the
ENTER button and
is showing on the display. Pressing
will blink on the display, use DOWN and UP button to adjust
the value from 125 to 255, press ENTER button to store and
will blink on the
display, use DOWN and UP button to adjust the value from 125 to 255, press ENTER button
to store and
will blink on the display, use DOWN and UP button to adjust the value,
press ENTER button to store. Idling 8 seconds automatically exit menu mode. Back to the
functions without any change press MENU button.
Display Inversion
It is good for you to install the unit on the floor or under ceiling. Press the MENU button up to
when the
is blinking on the display. Use the ENTER button to change to the mode
(display inversion), It will automatically store after 8 seconds. Or press the ENTER
button again return to the mode
(display normal). To go back to the functions press
the MENU button.
11-
16-
5.1. Master/Slave Built-In Preprogrammed Function
Display normal mode for the fixture putting on the floor.
Once you control the unit by Built-In program, be sure the unit is setting on
mode
Display inversion mode for the fixture fixing under ceiling.
via menu.
Focus Adjust
By linking the units in master/slave connection, the first unit will control the other units to
give an automatic, sound activated, synchronized light show. This function is good when you
Press the MENU button up to when the
want an instant show. You have to select show (show 1, 2, 3, 4) modes for the first unit
button, the unit will focus on tilt 90°, and then the unit will focus on tilt 0°, pan 0°, pan 90°,
(master). Its DMX input jack will have nothing plugged into it, and Its master LED will be
pan 180°, pan 270° in every pressing ENTER button. To go back to the functions press the
constantly on and sound LED will flash to the music. The other units will have to set in slave
MENU button again.
mode
and select
(normal) or
(2 light show) mode, Their DMX
Self-Test
cables plugged into the DMX input jacks (daisy chain) and the slave LED lights will
constantly on.
Press the MENU button up to when the
is blinking on the display. Pressing ENTER
button and the unit will run self-test by built-in program. To go back to the functions press the
2-light show
In
is blinking on the display. Pressing ENTER
(slave mode),
means the unit works normally and
2-light show. In order to create a great light show, you can set
means
MENU button again.
on the second unit
Ambient temperature of lamp
to get contrast movement to each other, even if you have two units only.
Press the MENU button up to when the
5.2. Easy Controller
is blinking on the display. Pressing
ENTER button and the ambient temperature of lamp will show on the display. To go back to
The easy remote control is used only in master/slave mode. By
the functions press the MENU button again.
connecting to the 1/4” microphone jack of the first unit, you will find
Fixture Hours
that the remote control on the first unit will control all the other units for
Stand by, Function and Mode.
Press the MENU button up to when the
is blinking on the display. Pressing ENTER
button and the display will show the number of working hours of the unit. To go back to the
functions press the MENU button again.
Stand by
Function
Mode
Blackout the unit
Strobe
1. Color sync. strobe
2. Sync. strobe
3. Two-light strobe
Sound 1
(LED off )
X/Y moving show pattern Gobo/Color selection
X/Y moving setting
selection
1.Hold on for gobo 1.Macro(sound active)
( Show 1 ~ Show 4 )
selection
2.Fade (sound invalid)
Please refer to 4.2. Main 2.Press for color change
Functions- Show mode
Sound 2
(LED slow blinking)
Slow/Sound 3
(LED on)
Position/ Latch
(LED fast blinking)
Lamp ON/OFF
Press the MENU button up to when the
is blinking on the display. Pressing ENTER
button and the display will blink. Use DOWN and UP button to select the
or
(Lamp on)
(Lamp off) mode. Once the mode has been selected, press the ENTER button
to setup. Idling 8 seconds automatically exit menu mode. Back to the functions without any
change press MENU button.
5.3. DMX Controller
If you use a universal DMX controller to control the units, you have to set DMX address from
1 to 512 channel so that the units can receive DMX signal.
Press the MENU button up to when the
is shown on the display. Pressing ENTER
Reset
Press the MENU button up to when the
is blinking on the display. Pressing ENTER
button and all channels of the unit will return to their standard position. It will cost about 20
button and the display will blink. Use DOWN and UP button to change the DMX512 address.
15-
12-
seconds and then automatically exit menu mode.
up to when the
is shown on the display. Pressing ENTER button and the display
will blink. Use DOWN and UP button to adjust the tilt home position. Once the position has
DMX RESET :
Set DMX value of channel 8 and channel 16 to 255, then all channels of the unit will return to
been selected, press the ENTER button to setup or automatically return to the offset
their standard home position.
functions without any change press the MENU button again, To go back to the main
functions without any change after 8 seconds.
4.3 Home Position Adjustment
Gobo offset
Press MENU button for at least 5 seconds into offset mode to adjust the home position,
when you want to adjust pan and tilt home position, you should be run
mode first ,
the functions are shown below:
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
up to when the
is shown on the display. Pressing ENTER button and the display
will blink. Use DOWN and UP button to adjust the gobo home position. Once the gobo has
been selected, press the ENTER button to setup or automatically return to the offset
functions without any change press the MENU button again, To go back to the main
functions without any change after 8 seconds.
Color offset
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
up to when the
Focus Adjust
is shown on the display. Pressing ENTER button and the display
will blink. Use DOWN and UP button to adjust the color home position. Once the color has
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
been selected, press the ENTER button to setup or automatically return to the offset
is shown on the display. Pressing ENTER button, the unit will focus
functions without any change press the MENU button again, To go back to the main
up to when the
on the center position. Use DOWN and UP button to adjust focus, this settings only for offset
functions without any change after 8 seconds.
mode to adjust home position. To go back to the main functions without any change after 8
5. How To Control The Unit
seconds
You can operate the unit in three ways:
Pan offset
1. By master/slave built-in preprogrammed function
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
up to when the
is shown on the display. Pressing ENTER button and the display
2. By easy controller
3. By universal DMX controller
will blink. Use DOWN and UP button to adjust the pan home position. Once the position has
No need to turn the unit off when you change the DMX address, as new DMX address
been selected, press the ENTER button to setup or automatically return to the offset
setting will be effected at once. Every time you turn the unit on, it will show I250 on the
functions without any change press the MENU button again, To go back to the main
display and move all the motors to their ‘home’ position and you may hear some noises for
functions without any change after 8 seconds.
about 20 seconds. After that the unit will be ready to receive DMX signal or run the built-in
programs.
Tilt offset
Press the MENU button for at least 5 seconds into offset mode, use DOWN and UP button
13-
14-
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF