Wind Instrumentation Catalog
WIND
T H E
W O R L D
O F
W E A T H E R
D A T A
THE WORLD OF WEATHER DATA
Measurement and Documentation:
Thies’ range of service for meteorolgy,
environmental protection and industry
Today more than ever, the
measurement, processing and
analysis of meteorological data
requires a high degree of measurement instrument precision
and an optimal adaption of the
data acquired to the task at
hand.
For more than 50 years, we
have been developing, producing and supplying practical
instruments and systems for
the analysis of weather data.
Today we are one of the
world’s largest suppliers of
such equipment.
Our close cooperation with
scientific institutions and
governmental agencies in
many countries guarantees a
constant and up-to-date flow of
information about all aspects
of individual national problems
and projects and the rapid
implementation of state-ofthe-art developments and
measurement techniques.
Our instruments and systems
fulfill in all respects both to
the requirements of national
weather services as well as
those of the World
Meteorological Organization
in Geneva.
Meteorological observations
without computer-aided measurement and documentation
systems are unthinkable today.
THIES develops complete
ready-for-use-systems which
include precision data transmitters, data loggers, power
supply units and personal computers with adapted software.
Wind
Glossary
Damping coefficient
The damping coefficient characterises the oscillations of the wind vane. It
is an important characteristic quantity for the qualitative evaluation of the
wind vane. The damping coefficient is determined from the amplitudes of
two successive excursions and is calculated by means of an equation.
Damping ratio
Measure for the damping of wind vanes. It represents the ratio between
the consecutive damped deflection amplitudes (for example 3rd amplitude to 1st amplitude) in one direction.
Wind run
The path covered by the wind for a certain period of time.
Gray-Code
A digital code for wind direction whereby the codes for consecutive
numbers differ by only one bit.
Delay distance
The path covered by the wind which is reached when, after a sudden
change in wind speed, the speed reaches 63% of its end value.
Stress
Maximum allowable wind speed at which no damage occurs on the wind
measuring instruments.
Wind force
»Beaufort« (bft) classes for certain wind speed ranges.
bft
0
1
2
3
4
5
6
7
8
m/s
0 - 0,2
0,3 - 1,5
1,6 - 3,3
3,4 - 5,4
5,5 - 7,9
8,0 - 10,7
10,8- 13,8
13,9 - 17,1
17,2 - 20,7
bft
9
10
11
12
13
14
15
16
17
m/s
20,8 - 24,4
24,5 - 28,4
28,5 - 32,6
32,7 - 36,9
37,0 - 41,4
41,5 - 46,1
46,2 - 50,9
51,0 - 56,0
56,1 - 61,2
Wind speed
The most common units of measurement are: 1 m/s = 3.6 km/h
= 1.9455 knots
Wind direction
Information on the direction from which the wind is coming.
Information appears clockwise from North to East (90°), South (180°) and
West (270°) and North (360°).
Starting value
The wind speed at which a cup anemometer respectively the wind vane
starts to move.
Detection limit
The lowest value of wind speed and wind direction at which a stable
value sets in.
Variation
The range within which wind direction has changed within the preceding
10 minutes (in accordance with ICAO).
Gliding mean value
The mean value which is updated as the mean value time at short time
intervals.
(for example the 10 min.-mean value is updated once a second )
Arithmetic mean value
The quotient from the sum of all the individual values and the number of
values within the mean value time.
Vectorial mean value
Method of calculation: The individual vectors, measured as wind speed
and direction, are decomposed into rectangular components. The components are averaged arithmetically, these mean values are then composed
into a vectorial mean value.
Vectorial mean value
with standard vectors
Only used for wind direction. A constant wind speed is assumed for the
individual vectors.
Wind
Ultrasonic
System Examples:
The Ultrasonic Anemometer
2D with acoustic measuring
principle allows a high precision measurement of running
variable wind dimensions and
an inertia-free peak value
acquisition.
ultrasonic
anemometer 2D
Applications:
■ Meteorology
■ Climatic Network
■ Research
■ Development
power supply unit
connection box
standard input
for example:
0 ... 20 mA
displays
■ visualisation
■ recording
pc-software
»Online-Wind«
datalogger
■ recording
■ controlling
■ data processing
THIES projects, configures,
and supplies your individual
system. Of course, your
measurement tasks and the
existing system pre-conditions
will be in our focus.
2
Please do not hesitate to
contact us for a detailed
information.
Wind
Ultrasonic
Description
Order-No.
Technical Data
Anemometer
Ultrasonic 2D
4.3800.00.XXX
Wind Speed
Meas. range
Resolution
Accuracy
The Ultrasonic-Anemometer
serves for the acquisition of
the horizontal components
of the wind speed, wind
direction, and virtual
temperature.
Wind direction
Meas. range
Resolution
Accuracy
Virtual Temp
Meas. range
Resolution
Accuracy
Data output
digital
Interface
Baud rate
output
The measuring values are
output in digital and analogue
form. The analogue values are
available as voltage- or current
signals for wind speed and
wind direction.
The measuring values can be
output alternatively as instantaneous values or as gliding
mean values of 1s, 10 s,
1, 2 and 10 minutes.
output rate
The output formats of the data
telegrams and analogue
signals as well as the userspecific parameters such as
north correction, are selectable
via the serial interface.
Status signal
Data output analogue
Electr. output
only WS and WD
The sensor arms are automatically heated in case of critical
ambient temperatures, so that
the function is guaranteed
even with snow and icing rain.
Output
Output rate
Resolution
General
Internal meas. rate
Averaging for WS and
WD
Operating voltage
w/o heating
with heating Electr.
connection
Housing material
Protection
Dimensions
Weight
The instrument can be mounted onto a mast of ø 50 mm.
Anemometer
Ultrasonic 2D
4.3800.20.XXX
0 - 65 m/s
0,1 m/s
± 0,1 m/s (0 - 5 m/s)
± 2% rms ( > 5 m/s )
1 - 360°
1°
± 1°
- 40 - + 70 °C
0,1 K
± 0,5 K
RS 485 / 422
1200…19200
selectable
instantaneous value
or gliding mean value
1 per 100 m/sec. up to
1 per 25 sec.
selectable
heating, meas.
distance error, T
distance temp.
0 - 10 V (>1 k) or
0/4 - 20 mA (< 250 )
Instantaneous value or
gliding mean value
1 pro 100 msec.
12 bit
400 Hz at 25°
vectorial or scalar
12 - 24 V AC/DC , 3 VA
24 V AC/DC, 70 VA
16 pole plug
stainless steel, V4A
IP 65
420 x 270 mm
2.5 kg
Techn. Data
see above
Thanks to the additionally
installed US transducer heating
the anemometer is especially
suited for the difficult use in
high mountains or other critical
measuring places where you
have to reckon on snow or
icing.
Accessories
Connection Cable, compl. 506702
(not depicted)
Shielded cable with plug to the
transmitter and multi-core
cable end.
506872
506883
Software Meteo- Online
9.1700.98.XXX
Cable length
15 m
25 m
30 m
see page 28
For other accessories such as masts, lightning rods, power supply etc. please refer to pages 32 - 36
5
Wind
Ultrasonic, Advance
Model Brief Description
Order-No.
Technical Data
Anemometer
Ultrasonic 2D a
4.3810.00.xxx
Wind speed
Measuring range
Resolution
The Ultrasonic-Anemometer
serves for the acquisition of
the horizontal components of
the wind speed, wind direction,
and virtual temperature.
More efficient instrument
compared with Ultrasonic
4.3800 due to broaden technology. Therefore especially
suited for the use in the
domain of science.
- configurations acc. to customer or factory requirements
with many alternatives for
commands .
- other pre-defined data
telegrams, for ex. scientific
diagnosis telegram, error
telegram.
The measuring values can
be output as digital and/or
analogue values.
Digital output:
An interface RS485/422 is
available for serial communication. It can be operated in
full- or semi-duplex mode.
For the output of measuring
values are available: some
pre-defined telegrams or a
user-defined telegram
(for ex. WS, WD, virtual-temp.,
standard deviation, status
information, NMEA etc.)
Analogue outputs:
Wind speed and direction are
output alternatively as current
or voltage signal.
The scaling of measuring range
of the analogue outputs are
selectable for WS and WD.
The analogue outputs can
be connected optionally
as analogue voltage inputs
(max. 3 units.) Output via
serial interface with userdefined telegram.
The sensor arms are automatically heated in case of critical
ambient temperatures, so that
the function is guaranteed even
with snow and icing rain.
The instrument can be
mounted onto a mast of
Ø 50 mm.
4
Accuracy
Wind direction
Measuring range
Resolution
Accuracy
Virtual Temp.
Measuring range
Resolution
Accuracy
Data output digital
Interface
Baud rate
Output
Output rate
Status signal
0 - 65 m/s
0,1 m/s ( standard )
0,01 ( user-defined )
± 0,1 m/s rms
(0 - 5 m/s)
± 2% rms ( > 5 m/s )
0 - 360°
(0-540°, 0-720°)
1°
± 1°
- 40 - + 70 °C
0,1 K
± 0,5 K
RS 485 / 422
1200…921600
selectable
instantaneous values
or
gliding mean values
of 0,5 sec.- 100 min.
1 per 1 msec. to
1 per 60 sec.
selectable
heating, meas.
distance error, T
distance temp.
Data output analogue
Electr. output
(only WS and WD)
0- 20 mA / 0 - 10 V or
4 - 20 mA / 2 – 10 V
Load
Current output
Voltage output
max. 400 min. 4000 or as:
Data input
0...10 V
Output
Output rate
Resolution
General
Internal meas.rate
Averaging for WS
and WD
Operating voltage
w/o heating
with heating
Electr. connection
Housing material
dimensions
Weight
EMC
instantaneous values
or gliding mean values
of 0,5 sec.- 100 min.
1 per 100 msec.
12 bit
max. 1500 Hz at 25°
vectorial or scalar
12 - 24 V AC/DC , 3 VA
24 V AC/DC,
max. 70 VA
8 pole plug
stainless steel, V4A
420 x 270 mm
2,5 kg
EN 55022 5/95 B
EN 50082-2 2/96
Wind
Ultrasonic, Advance
Model Brief Description
Order-No.
Technical Data
Anemometer
Ultrasonic 2D a
4.3810.20.XXX
Techn. Data
See above
Thanks to the additionally
installed US transducer heating
the anemometer is especially
suited for the difficult use in
high mountains or other critical
measuring places where you
have to reckon on snow or
icing.
Device to Refuse Birds
507245
The device to refuse birds
prevents the birds from sitting
on, thus avoiding possible
damages at the instrument.
Suitable for:
Ultrasonic Anemometer
4.3800.... u. 4.3810....
For other accessories such as masts, lightning rods, power supply etc. please refer to pages 30 - 34
5
Wind
Classic
System Examples:
wind
transmitter
combined
wind transmitter
wind direction
transmitter
traverse
power supply unit
connection box
standard input
for example:
0 ... 20 mA
displays
■ visualisation
■ recording
6
pc-software
»Online-Wind«
datalogger
■ data processing
■ controlling
■ recording
Wind
Classic
Description
Order-No.
Technical Data
4.3303.22.xxx
.000
Meas. range
Electr. output
Wind Speed Transmitters
Wind Transmitter
The wind transmitters is
designed for the directionindependent measurement of
the horizontal air-flow.
.007
Load
Delay distance
Accuracy
The wind transmitter is
equipped with a contact-free
opto-electronic scanner, which
causes an extremely low starting speed. At the output the
measuring value is available
as digital signal.
Operating voltage
Electronics
Heating
General
Ambient temp.
Electr. connection
with x.xxxx.xx.000
with x.xxxx.xx.007
The heating is electronically
controlled. A plug-connection
is situated in the shaft of the
instrument. The instrument is
mounted preferably onto a
mast or traverse. All essential
parts are made of anodised
aluminium, and are additionally varnished.
Wind Transmitter
This wind transmitter is
designed for high wind
speeds.
(for datalogger)
4.3303.22.0xx
008
018
4.3303.22.xxx
.0xx
.6xx
.x40
.x41
.x60
.x61
.x73
0.5 … 75 m/s
0 … 754 Hz (live zero)
0 … 754 Hz
(no live zero)
± 0.5 m/s / ± 2%
of m.v.
Meas. range
Electr. output
Operating voltage
Electronics
Heating
Electr. connection
This wind transmitter is
equipped with a DC-generator
which produces a d.c-voltage
with the rotation of the cup
star. It is able to operate a
respective display instrument
directly (without current
supply).
4.3105.22.000
5-pole plug connection
7-pole plug connection
Meas. range
Electr. output
Accuracy
Wind Transmitter
-35 ... +80°C
onto mast tube 1 1/2”
Ø 50 x 50 mm
Ø 315 x 230 mm
IP 55
1 kg
Operating voltage
Electronics
Heating
Electr. connection
The wind transmitter is
equipped with a contact-free
opto-electronic scanner.
A connected electronics
converts the speed-dependent
frequency into an analogue
output signal.
4...18 V DC
24 V AC/DC ; 20 W
Mounting
Fixing boring
Dimensions
Protection
Weight
Accuracy
Wind Transmitter
0.3 ... 50 m/s
3 ... 1042 Hz
(live zero)
3 ... 1042 Hz
(no live zero)
max. 60 m/s
5m
± 0.3 m/s / ± 2%
of m.v.
Meas. range
Electr. output
Load
Accuracy
Heating
Electr. connection
4...18 V DC
24 V AC/DC ; 20 W
5-pole plug connection
0,3 ... 50 m/s
0,3 ... 60 m/s
0 ... 20 mA
4 ... 20 mA
0 ... 1 V
0 ... 10 V
0 ... 5 V
± 0,4 m/s / ± 2,5%
v. Mw.
15...24 V DC
24 V AC/DC ; 20 W
5-pole plug connection
0.5 ... 35 m/s
0 ... 4.67 mA DC,
linear Ra = 400 max. 60 m/s
± 0.5 m/s/ ± 2% v. Mw.
24 V AC/DC; 20 W
5-pole plug connection
7
Wind
Classic
Description
Order-No.
Technical Data
4.3120.22.xxx
.012
.018
Potentiometer
0 - 2000 0 - 400 Measuring range
Resolution
Accuracy
Operating voltage
Potentiometer
Heating
Load
Starting value
Damping coefficient
Ambient temperature
Electr. connection
Mounting
Dimensions
Protection
Weight
Wind Direction
Transmitter
Wind Direction
Transmitter
Measuring value transmitter
for measuring the direction
of the horizontal air flow.
Potentiometer-wind-directiontransmitters are equipped with
a sliding potentiometer which
offers a theoretically unlimited
resolution.
The heating is electronically
controlled. A plug-connection
is situated in the shaft of the
instrument. The instrument is
mounted preferably onto a
mast or traverse. All main
parts are made of anodised
aluminium, and are additionally varnished.
Wind Direction
Transmitter
Measuring value transmitter
for measuring the direction
of the horizontal air flow.
4.3125.32.xxx
.040
.041
.060
.061
.073
The wind direction transmitter
is equipped with an optoelectronic scanner (code disc),
which causes an extremely low
starting speed, and operates
in wear-resistant manner. The
digital measuring signals are
transformed by an internal
measuring transformer.
The output is available as
analogue current- or voltage
signal.
Measuring value transmitter
for measuring the direction
of the horizontal air flow.
The position of the wind vane
is detected opto-electronically
by a code disc, which causes
an extremely low starting
speed, and operates in wearresistant manner.
The output is available as serial
or as parallel digital signal.
4.3121.32.000
4.3125.32.100
0 - 20 mA
4 - 20 mA
0- 1V
0 - 10 V
0- 5V
Measuring range
Resolution
Accuracy
Load
Starting value
Damping coefficient
Operating voltage
Heating
Ambient temperature
Electr. connection
Mounting
0 - 360°
2,5°
± 2,5°
max. 60 m/s
< 0.6 m/s at 90°
0.2 ... 0,3
14 - 18 V DC
24 V AC/DC, max. 20 W
- 35 ... + 80 °C
5-pole plug connection
onto a mast tube
1 1/2”
415 mm high
1,8 kg
Digital Output
Measuring range
Resolution
Accuracy
Load
Starting value
Damping coefficient
Operating voltage
Electronics
Heating
Ambient temperature
Electr. connection
with xx.xxxx.000
with xx.xxxx.100
Mounting
10
12 V DC, max 1.5 W
24 V AC/DC, max.20W
max. 60 m/s
0.5 m/s at 90°
0.2 ... 0.3
- 35 ... + 80 °C
8-pole plug connection
onto mast tube 1 1/2”
415 mm high
IP 55
1.8 kg
Analogue Output
Dimensions
Weight
Wind Direction
Transmitter
Measuring Range
358 ° ( ± 3° ) 5
-lead circuit
0 - 360°
1°
± 1.5°
Dimensions
Weight
8-bit parallel
8-bit THIES serial
0 - 360°
2.5°
± 2.5°
max. 60 m/s
< 0.6 m/s at 90°
0.2 ... 0.3
5 / 3.5 - 18 V DC
24 V AC/DC, max. 20W
- 35 ... + 80 °C
19 pole plug
connection
7-pole plug connection
onto a mast tube
1 1/2”
415 mm high
1.8 kg
Wind
Classic
Desription
Order-No.
Technical Data
Combined Wind
Transmitter
Combined Wind
Transmitter
Measuring value transmitter for
the measurement of the wind
speed and wind direction of
the horizontal air flow.
4.3324.31.xxx
.0xx
.6xx
.x40
.x41
.x61
.x73
The cup star revolution is
scanned opto-electronically in
contact-free and wear-resistant
manner. It has an extremely
low starting speed.
Electr. output
Meas. range WD
Accuracy
Load
Delay distance
Responsiveness
Damping coefficient
Operating voltage
The position of the wind vane
is detected opto-electronically
by a code disc.
The digital measuring signals
are transformed by an internal
measuring transformer.
Heating
Ambient temp.
Electr. connection
Fixing boring
Mounting
Total height
Protection
Weight
The output signals are
available as current or voltage
signals.
The heating is controlled
electronically. A plug connection is situated in the shaft of
the instrument. The instrument
is mounted preferably onto a
mast.
All main parts are made of
anodised aluminium, and are
additionally varnished.
Combined
Wind Transmitter
Meas. range WS
4.3324.31.000
.001
Model
Measuring value transmitter
for the measurement of the
wind speed and wind direction
of the horizontal air flow.
Meas. range
The cup star revolution is
scanned opto-electronically in
contact-free and wear-resistant
manner.
It has an extremely low starting
speed.
Resolution
Accuracy
The position of the wind vane
is detected opto-electronically
by a code disc.
The output signals are
available as frequency for wind
speed, and as 8-bit-Gray-code
(parallel) for wind direction.
The ship-version is equipped
with a strengthened cup star
and a smaller wind vane.
Electr. output
Operating voltage
Load
Delay distance
Responsiveness
Damping coefficient
Heating
Ambient temp.
Electr. connection
Fixing boring
Mounting
Total height
Weight
0.3 ... 50 m/s
0.3 ... 60 m/s
0 - 20 mA
4 - 20 mA
0 - 10 V
0-5V
0 - 360°
±0.5 m/s or
±2.0 % of meas. value
±2.5°
max. 60 m/s
5m
< 0,6 m/s at 90°
0.2 … 0.3
14 … 18 V DC or
24 V AC/DC w. heating
max. 40 W
-35 ... +80°C
multi-pole plug
Ø 50 x 50 mm
onto mast tube 1 1/2”
620 mm
IP 55
3.4 kg
Standard land version
Ship version
0.3 ... 50 m/s
0 ... 360°
3 ... 1042 Hz
8-bit-Gray-code
(parallel)
0.05 m ; 2.5°
±0,3 m/s or
±2 % of meas. value
±1,5°
15 V DC (5 … 18 V) or
24 AC/DC, w. heating
max. 60 m/s
5m
< 0.6 m/s at 90°
0.2 ... 0.3
max. 40 W
-35 ... +80°C
multi-pole plug
Ø 50 x 50 mm
onto mast tube 1 1/2”
620 mm
3,4 kg
9
Wind
Classic
Desription
Order-No.
Technical Data
Combined Wind
Transmitter
4.3336.21.000
4.3336.31.000
.001
Model
Measuring value transmitter
for the measurement of the
wind speed and wind direction
of the horizontal air flow.
The cup star revolution is
scanned opto-electronically in
contact-free and wear-resistant
manner.
It has an extremely low starting
speed.
The position of the wind vane
is detected opto-electronically
by a code disc.
The output signals are
available as frequency for the
wind speed and as serialsynchronous 8-bit for wind
direction.
Meas. range ws
Meas. range wd
Electr. output ws
Electr. output wd
Resolution
Accuracy
Load
Delay distance
Starting value
Damping coefficient
Operating voltage
Heating
Ambient temp.
Electr. connection
Fixing boring
Mounting
Total height
Protection
Weight
for data logger
standard land
ship version
0.3 ... 50 m/s
0 ... 360°
3 ... 1042 Hz
serial synchron. 16 bit
0.05 m ; 2.5°
± 0.3 m/s or ± 2 %
of meas. value
± 1.5°
max. 60 m/s
5m
< 0.6 m/s at 90°
0.2 … 0.3
4 … 18 V DC
40 W, 24 V AC/DC
-35 ... +80°C
multi-pole plug
Ø 50 x 50 mm
onto mast tube 1 1/2”
620 mm
IP 55
3.4 kg
The ship-version is equipped
with a strengthened cup star
and a smaller wind vane.
10
For other accessories such as masts, lightning rods, power supply etc. please refer to pages 30 - 34
Wind
First Class
Description
Order-No.
Technical Data
4.3350.00.000
.10.
With heating
W/o heating
Wind Speed Transmitter
Wind Transmitter
“First Class”
The wind transmitter is
designed for the acquisition
of the horizontal component
of the wind speed in the field
of meteorology and environmental measuring technology,
evaluation of location, and
measurement of capacity
characteristics of wind power
systems. In the plain country
the wind transmitter meets
all requirements of
IEC 61400.121-CD for a
1. class instrument. Special
characters are a defined and
optimised, dynamic behaviour
also at high turbulence intensity, minimal over-speeding,
and a low starting value.
The measuring value is
available at the output as
digital signal. It can be transmitted to display instruments,
recording instruments, data
loggers as well as to process
control systems. For winter
operation the instrument is
equipped with an electronically
regulated heating, which
guarantees a smooth running
of the ball bearings, and
prevents the shaft and slot
from icing-up
Measuring range
Accuracy
0,3 ... 50 m/s
50 ... 75 m/s
Linearity
0.3...75 m/s
< 3% of meas. value
or < 0.3 m/s
< 6% of meas. value
r > 0.999 95 (4..20m/s)
Inclined flow
...mean deviation
1% (in the range ±20°)
from the cosinus line
Turbulence effect
Electr. output
Load
Delay distance
Operating voltage
Electronics
Heating
Ambient temp.
Electr. connection
Mounting
Fixing boring
Dimensions
Protection
Weight
Material
Housing
Cup star
<1% (in the range up
to 30%turbulence
intensity)
1000 Hz at 50 m/s
max. 85 m/s
<3m
3.3 … 42 V DC
24 V AC/DC; 25 W
-50 ..+ 80°C
8-pole plug connection
onto mast tube R 1”
Ø 35 x 25 mm
290 x 240 mm
IP 55
0.5 kg
alu, anodised
carbon-fibre-reinforced
plastic
Wind Direction
Transmitter
Wind Direction
Transmitter “First Class”
The wind transmitter is designed for the acquisition of the
horizontal component of the
wind direction in the field of
meteorology and environmental
measuring technology, evaluation of location, and measurement of capacity characteristics
of wind power systems.
Special characters are a defined and optimised, dynamic
behaviour.
Depending on the transmitter
model the measuring value is
available at the output as digital or analogue signal. The output signal can be transmitted
to display instruments, recording instruments, data loggers
as well as to process control
systems. For winter operation
the instrument is equipped
with an electronically regulated
heating.
4.3150.x0.0xx
.10.
.000
With heating
W/o heating
Meas. range
Accuracy
Electr. output
.110
Resolution
Electr. output
Resolution
General
Operating voltage
Electronics
Potentiometer
Heating
Ambient temp.
Starting value
Damping coefficient
Electr. connection
Mounting
Fixing boring
Dimensions
Protection
Weight
Material
0...360°
1.5°
digital, 9- bit Thies
serial synchronous
1°
Potentiom.
0 ... 10 000 W
1°
3,3 … 42 V DC
max. 0.5 W
24 V AC/DC; 25 W
-50 ..+ 80°C
0.5 m/s at 10° (acc. to
ASTM D5366-96)
≥ 0.4
8-pole plug connection
onto a mast tube R 1”
Ø 35 x 25 mm
390 x 240 mm
IP 55
0.5 kg
alu, anodised
For other accessories such as masts, lightning rods, power supply etc. please refer to pages 30 - 34
11
Wind
Compact
System Examples:
Wind Sensor and Wind
Direction Sensor for
qualified technical
Requirements.
wind
transmitter
wind direction transmitter
Applications:
■ Building Control Technology
■ Industry
■ Wind Power Systems
■ Environmental
Protection Sector
■ Wind Warning Systems
traverse
power supply unit
connection box
standard input
for example:
0/4 ... 20 mA
displays
■ visualisation
■ recording
pc-software
»Online-Wind«
datalogger
■ recording
■ controlling
■ data processing
THIES projects, configures,
and supplies your individual
system. Of course, your
measurement tasks and the
existing system pre-conditions
will be in our focus.
12
Please do not hesitate to
contact us for a detailed
information.
Wind
Compact
Description
Order-No.
Technical Data
4.3518.00.000
4.3520.00.000
4.3520.10.000
With heating
With heating
W/o heating
open collector sink
open collector source
open collector source
Measuring range
Accuracy
0.5 ... 50 m/s
± 3 % of meas. value
or ± 0.5 m/s
< 0.1 m/s
2 ... 573 Hz
12 - 24 V DC
20 mA
max. 20 W ; 24 V
AC/DC
- 30 ... + 70 °C
5m, LiYCY
5 x 0.25 mm2
Ø 135 x 165 mm
IP 55
0.4 kg
Wind Speed Transmitters
Wind Transmitter
compact
Measuring transmitter for the
measurement of the horizontal
wind speed with digital output
signal (open collector).
The cup-star consists of
plastic, the housing is made
of anodised aluminium and
plastic.
The instrument has a threaded
pin PG 21 with 2 nuts for
mounting.
Resolution
Electr. output
Operating voltage
Current supply
Heating
Ambient temp.
Cable
Dimensions
Protection
Weight
Wind Transmitter
compact
4.3519.00.000
Measuring transmitter for the
measurement of the horizontal
wind speed with digital output
signal (active signal).
Suitable for data loggers.
The cup-star consists of plastic,
the housing is made of anodised aluminium and plastic.
The instrument has a threaded
pin PG 21 with 2 nuts for
mounting.
Wind Transmitter
compact
Measuring transmitter for the
measurement of the horizontal
wind speed with analogue
output signals.
The cup-star consists of plastic,
the housing is made of anodised aluminium and plastic.
The instrument has a threaded
pin PG 21 with 2 nuts for
mounting
Measuring range
Accuracy
Resolution
Electr. output
Operating voltage
Current consumpt.
Heating
Ambient temp.
Cable
Dimensions
Weight
4.3519.00.xxx
.140
Electr. Output
0 - 20 mA
Dimensions
Weight:
Load (with operat. volt.)
max. 500 ;
(>13 V DC )
max. 500 ;
(>13 V DC )
min. 1 k
min. 1 k
min. 1 k
0.5 ... 50 m/s
± 3 % of meas. value
or ± 0.5 m/s
< 0.1 m/s
9 - 30 V DC or
24 V AC/DC
13 - 30 V DC
approx. 10 mA,
unloaded
max. 20 W ; 24 V
AC/DC
- 30 ... + 70 °C
12 m, LiYCY
6 x 0.25 mm2
Ø 135 x 165 mm
0.75 kg
Plug connection
Weight
Multi-pole
0.4 kg
.141
4 - 20 mA
.161
.167
.173
0 - 10 V
0- 2V
0- 5V
Measuring range
Accuracy
Resolution
Operating voltage
for 0 - 10 V output.
Current supply
Heating
Ambient Temp.
Cable
Wind Transmitter
compact
Model with plug connection
(without cable)
4.3518.00.700
4.3519.00.700
4.3519.00.741
4.3519.00.761
0.5 ... 50 m/s
± 3 % of meas. value
or ± 0.5 m/s
< 0.1 m/s
2 ... 630 Hz
4 - 18 V DC
< 1 mA
max. 20 W ; 24 V
AC/DC
- 30 ... + 70 °C
12m , LiYCY
6 x 0.25 mm2
Ø 135 x 165 mm
0.75 kg
Other technical data
see above
Wind
Compact
Description
Order-No.
Technical Data
4.3128.xx.000
.00...
With heating
Wind Direction
Transmitters
Wind Direction
Transmitter compact
Measuring transmitter for the
measurement of the horizontal
wind direction with digital
output signal (Gray-code).
.10...
The wind vane consists of
plastic, the housing is made
of anodised aluminium and
plastic.
The instrument has a threaded
pin PG 21 with 2 nuts for
mounting.
Without heating
Measuring range
Accuracy
Resolution
Electr. output
Starting value
Operating voltage
Current supply
Ambient temp.
Cable
Dimensions
Protection
Weight
Wind Direction
Transmitter compact
4.3129.00.000
Measuring transmitter for the
measurement of the horizontal
wind direction with digital
output signal (Gray-code).
Suited for data logger
operation.
Operating voltage
Current supply
Heating
The wind vane consists of
plastic, the housing is made
of anodised aluminium and
plastic.
The instrument has a threaded
pin PG 21 with 2 nuts for
mounting.
Wind Direction
Transmitter compact
Measuring transmitter for the
measurement of the horizontal
wind direction with analogue
output signals.
The wind vane consists of
plastic, the housing is made
of anodised aluminium and
plastic.
The instrument has a threaded
pin PG 21 with 2 nuts for
mounting.
Measuring range
Accuracy
Resolution
Electr. output
Ambient temp.
Cable
Dimensions
Weight
4.3129.00.xxx
.140
Electr. output
0 - 20 mA
.141
4 - 20 mA
.161
.167
.173
0 - 10 V
0- 2V
0- 5V
Measuring range
Resolution
Accuracy
Operating voltage
Model with plug connection
(without cable)
0 ... 360°
± 5°
11.25°
serial synchronous
5 bit Gray-code
5 - 18 V DC
standby < 15 mA (5 V )
active approx.
500 mA (5 V)
max. 20 W ;
24 V AC/DC
- 30 ... + 70 °C
12 m, LiYCY
6 x 0.25 mm2
50 x 220 mm
1.1 kg
Load (operat. Volt.)
max. 500 ;
(>13 V DC )
max. 500 ;
(>13 V DC )
min. 1 k
min. 1 k
min. 1 k
Dimensions
Weight
Plug connection
Weight
Multi-pole
0.4 kg
Ambient temp.
Cable
4.3129.00.700
4.3129.00.741
4.3129.00.761
4.3129.00.767
0 ... 360°
± 5°
90° , 45° , 22,5°
2 , 3 , 4 bit Gray-code
0.3 m/s at 90°
18 ... 27 V DC
20 mA
- 30 ... + 70 °C
5 m, LiYCY
8 x 0.25 mm2
50 x 220 mm
IP 55
0.6 kg
0 ... 360°
11.25°
± 5°
9 - 30 V DC or
24 V AC/DC
13 - 30 V DC
max. 20 W ;
24 V AC/DC
- 30 ... + 70 °C
12m, LiYCY
6 x 0.25 mm2
50 x 220 mm
1.1 kg
for 0 - 10 V-output
Heating
Wind Transmitter
compact
max. 20 W ;
24 V AC/DC
Other technical
data see above
Wind
Small Wind Transmitter
Technical Data
Description
Order-No.
Wind Speed Transmitters
Small Wind Transmitter
4.3400.30.000
Measuring instrument for
the direction-independent
measurement of the horizontal
air flow in the open.
The sensor is a small construction with a DC-generator, which
is moved by the revolution of
the cup-star.
The transmitter is made of
synthetic material
Small Wind Transmitter
Measuring range
Accuracy
Electr. output
Load
Fixing boring
Mounting
Ambient temp.
Cable
Dimensions
Protection
Weight
4.3515.30.000
Measuring instrument for the
direction-independent measurement of the horizontal air
flow in the open.
The sensor is a small construction with a Reed-contact,
which is activated by the
revolution of the cup-star.
The transmitter is made of
synthetic material
Measuring range
Accuracy
0.5 ... 40 m/s
± 5% of meas. range
or ± 0.5 m/s
Electr. output
Resolution
Load
Contact load
RV
Fixing boring
Mounting
Ambient temp.
Cable
50 Hz at 40 m/s
0.8 m wind run
max. 60 m/s
max. 24 V DC
0.5 W, 100 Ø 35 x 35 mm
onto a mast tube 1"
-25 ... +60°C, ice-free
20 m, LiYY
2 x 0.25 mm2
Ø 134 x 175 mm
IP 54
0.3 kg
Dimensions
Protection
Weight
Small Wind Transmitter
Measuring instrument for the
direction-independent measurement of the horizontal air
flow in the open.
The sensor is a small construction with a Reed-contact,
which is activated by the
revolution of the cup-star.
The housing is made of
synthetic material.
4.3515.xx.xxx
.50.xxx
.51.xxx
.0xx
.1xx
.x00
.x61
With heating
Without heating
Instrument colour
max. 24 V DC; 24 W
white
black
Electr. output
0 … 100 Hz
0 … 10 V
Measuring range
Accuracy
Resolution
Load
Contact load
Fixing boring
Mounting
Ambient temp.
Cable
Dimension
Protection
Weight
Small Wind Transmitters are ideal measuring transmitters
with best price/performance-ratio for standard requirements.
Applications:
■ Control technique
■ Building control system
0.5 ... 35 m/s
± 5% of meas.range
or ± 0.5 m/s
0 ... 1 mA DC
Ra = 800 max. 60 m/s
Ø 35 x 35 mm
onto a mast tube 1"
-25 ... +60°C, ice-free
20 m, LiYY
2 x 0.25 mm2
Ø 134 x 175 mm
IP 54
0.3 kg
1 ... 40 m/s
± 5% of meas. range
or ± 0.5 m/s
0.4 m wind run (..x00)
max. 60 m/s
10 VA, max. 42 V DC
max. 0.4 A
Ø 35 x 35 mm
on mounting angle
-25 ... +60°C
3 m; LiYY 4 x 0.5 mm2
or 2 x 0.5 mm2
Ø 134 x 160 mm
IP 54
0.3 kg
Wind
Small Wind Transmitter
Description
Order-No.
Technical Data
4.3124.30.018
Electr. output
Resolution
0 - 400 (358°)
0.5°, 5-lead circuit
4.3127.40.000
Electr. output
Resolution
8 Reed contacts
22.5°
Measuring range
Potentiometer load
0 ... 358° / 0 ... 360°
max. 100 ma,
24 V, 2.5 W
0.5 W, max. 60 V DC
max. 60 m/s
-25 ... + 60° C, ice-free
20 m; LiYY
5 x 0.25 mm2
or 9 x 0.14 mm2
onto a mast tube 1”
210 mm high
IP 54
0.55 kg
Wind Direction
Transmitters
Wind Direction
Transmitter
Measuring sensor for the
measurement of the horizontal
wind direction in the open.
The instrument is a small construction with a potentiometer
or Reed-contact, which are
activated in correspondence to
the position of the wind vane.
The instrument is made of
synthetic material.
Contact load
Load
Ambient temp.
Cable
Mounting
Dimension
Protection
Weight
Wind Direction
Transmitter
Measuring transmitter for the
measurement of the horizontal
wind direction. The measuring
values are output as ohmic
resistance-signals. The wind
direction is detected by a wind
vane, and is then transmitted
to a potentiometer.
The outer parts of the instrument are made of corrosionresistant materials (plastic).
Labyrinth gaskets protect the
parts inside the instrument
against humidity.
16
4.3140.51.010
Measuring range
Electr. output
Responsiveness
Potentiometer load
Ambient temperature
Electr. connection
Dimensions
Protection
Weight
10°... 350°
(20° dead-zone
in the north)
Potentiometer
0 ... 1 K (±3%)
1 m/s
max. 1.5 W
-25 ... + 60° C, ice-free
3 m cable
210 mm high
IP 54
0.3 kg
For other accessories such as masts, lightning rods, power supply etc. please refer to pages 30 - 34
Wind
Direction-dependent
Description
Order-No.
Technical Data
Anemometer
Ultrasonic 1D
4.3860.00.340
Flow Speed
Meas. range
Resolution
Accuracy
The Ultrasonic Anemometer 1D
serves for the acquisition of
the horizontal air flow and
direction in tunnels, tubes or
similar applications. Due to
the high measuring rate the
instrument can be used also
for the inertia-free measurement of gust- and peak-values.
Direction detecting
Meas. range
Virtual Temp.
Meas. range
Resolution
Accuracy
Data output digital
Interface
Baud rate
Output
The measuring values are
available as analogue signals
and/or data telegram.
Status identification
The analogue output of the
flow speed is effected with or
without direction detecting.
1° / 181°
- 40 - + 70 °C
0,1 K
± 0.5 K
RS 485 / 422
9600
10 sec. gliding
mean value
heating, path
disturbance
Data output analogue
0 - 20 mA (< 250 W)
Electr. output
only WS and WD
10 sec. gliding
output
mean value
Operating voltage
12 - 24 V AC/DC, 3 VA
w/o heating
24 V AC/DC, 70 VA
with heating
3 m cable
Electr. connection
stainless steel, V4A
Housing material
420 x 270 mm
Dimensions
IP 66
Protection
2.5 kg
Weight
The digital output of the
flow speed is effected with
direction detecting, and
virtual-temperature.
If necessary, the sensor
branches are automatically
heated with critical ambient
temperatures. Thus, the function is guaranteed also with
negative temperatures.
Wind Transmitter
0 - 20 m/s
0.1 m/s
± 0.1 m/s (0 - 5 m/s)
± 2% rms ( > 5 m/s )
4.3308.10.000
for tunnel application
For the measurement of directional air flows especially in
tunnels. Instrument sends
frequency signals, depending
on speed and related to the
flow direction.
Instrument is equipped with a
mounting bar.
Suitable for connection to the
Measuring Transducer TW,
order-no. 4.3348.xx.xxx
Measuring range
Resolution
Delay distance
Electr. output
Propeller type
Dimension
Operating voltage
Current supply
Ambient temp.
Cable
Dimensions
Weight
Measuring transmitter for directional air flows.
Applications:
■ Air Channels Shafts
■ Climatic Ducts
■ Street and Railway Tunnels
0.3 ... 20 m/s
approx. 0,05 m
wind run
3.3 m
0 ... 410 Hz
resp. 418 Hz
4-blade,
polypropylene
Ø 180 mm
15 V DC (10 - 16 V DC)
approx.. 15 mA
-20 ... +70 °C, ice-free
3 m, LiYCY
4 x 0.25 mm2
Ø 200 x 350 mm
5 kg
Wind
Direction-dependent
Description
Order-No.
Technical Data
Wind Transmitter
4.3311.30.000
Operating voltage
for duct application
4.3311.32.000
A fan wheel to determine the
directional air flow in ducts.
Mounting on a mast tube.
The fan wheel revolutions are
scanned opto-electronically by
a reflective light barrier in a
contact-free manner, thus causing a low starting speed.
Measuring range
Resolution
Electr. output
Fan wheel type
dimensions
Ambient temp.
Cable
Fixing boring
Dimensions
Weight
See also :
Measuring Transducer WG,
order-no.. 4.3339.xx.xxx
Measuring transmitter for directional air flows.
Applications:
■ Air Channels Shafts
■ Climatic Ducts
■ Street and Railway Tunnels
15 V DC /
approx. 0.3 mA
24 V DC
< 0.25 ... 20 m/s
0.083 m wind run
0 ... 240 Hz
8-blade aluminium
Ø 100 mm
-20 ... +80°C, ice-free
1 m long
Ø 37 x 20 mm
108 x 148 x 65 mm
0.9 kg
Wind
Hand Instruments, Mech. Anemometer, Wind Measuring Systems
Description
Order-No.
Technical Data
Cup-Anemometer
4.3008.01.000
Measuring range
Dimensions
Weight
0 ... 120 km/h
0 ... 12 Beaufort
0 ... 35 m/s
0 ... 70 kn
ø 100 x 205 mm
0.32 kg
4.3008.01.005
Material
Dimensions
Weight
wood
155 x 145 x 135 mm
1.15 kg
4.3018.10.000
Counting range
Resolution
Digit height
Inclination of counter
Operating range
Load
Delay distance
Ambient temp.
Mounting
0 ... 999 999.9 km
100 m wind run
7 mm
50 °
0.5 - 60 m/s
max. 60 m/s
5m
- 35 ... + 80 °C
onto a mast tube 1 1/2”
acc.to DIN 2441
ø 50 x 50 mm
318 x 260 mm
1.3 kg
A measuring instrument
designed for hand use to take
direct wind speed readings.
Made of plastic.
Instrument case
(not depicted)
Transport and storage
case for the above-mentioned
anemometer.
Wind Run Meter
Mechanical measuring instrument for direction-independent
measurement of the horizontal
air flow and display of the wind
run. The display count cumulatively the wind run.
Instrument is mounted on the
top of a mast.
All main parts are made of anodised or varnished aluminium
Mechanical
Wind Recorder
Fixing boring
Dimensions
Weight
4.3900.20.000
Dimensions
Weight
0 ... 10 km wind run
0 ... 360°
1 km ; 30°
50 mm = 10 km
36 mm = 360°
31 days
10 mm/h.
0,5 ... 60 m/s
- 35 ... + 60 °C
onto a mast tube,
ø 48 mm
155 x 200 x 725 mm
10.5 kg
205242
Paper length
Width of roll
sufficient for 31 days
120 mm
4.3905.20.000
Material
Dimension
Weight
wood, unvarnished
710 x 320 x 290 mm
12.5 kg
Scale division
Recording width ws
wd
Period of registration
Paper advance
Operating range
Ambient temp.
Mounting
A mechanical instrument
designed to measure and
record wind run and direction.
A reading rule to determine
both instantaneous and mean
wind speed values is included
in the shipment.
The paper transport is carried
out by a band mechanism with
spring wound drive.
Recording Roll
(not depicted.)
Wax coated paper for abovementioned wind recorder.
Instrument Case
(not depicted.)
For a safe transport of the
above instrument to varying
measuring places.
Measuring range
19
Wind
Hand Instruments, Mech. Anemometer, Wind Measuring Systems
Description
Order-No.
Technical Data
Wind Direction
Measuring Instrument
4.3019.21.000
Measuring range
Division
Alignment
Stand, telescopic
Dim. of case
Weight
0 ... 360°
10° and N-NW-W ...N
by compass
28 to 115 cm
395 x 285 x 120 mm
1 kg
Measuring value
wind direction
wind speed
temperature
wind-chill
min.- and max.-values
of the past 24 h.
4.3329.00.000
Operating voltage
Ambient temp.
Cable
Mounting
Dimensions
Weight
from display unit
-30 ... + 60 °C
20 m long, with plug
on pin ø 30 mm
200 x 450 mm
1 kg
9.3229.00.000
Display ws
Resolution
m/s ; km/h ; Bft
0.1 m/s ; 1 km/h ;
1 Bft
0 ... 360°
22.5°
-30 ... + 60 °C
-22 ... + 140 °F
0.1 K ; 0.1 °F
RS 232/V.24, serial
9 V DC / max. 500 mA
-30 ... + 60 °C, ice-free
Simple portable instrument,
consisting of a mechanical
wind vane, and a telescopic
tripod stand.
There is a built-in compass to
align the instrument to “North”.
Supplied in a carrying case
METEO comp
Complete measuring instrument, ready for connection,
consisting of the following
components:
Comb. Wind Transmitter
Small combined measuring
transmitter for acquisition of
the wind speed and wind direction as well as of the ambient
temperature.
Display Instrument
Digital LED-indicator inclusive
power supply unit, with plug
for the display of the abovementioned measuring values.
The changing-over to the
single values is carried out
via keypad.
Plug-connection of wind
sensor, power supply unit
and serial data output.
Housing is suited for wall
mounting.
Software Meteo-Online
20
Display wd
Resolution
Display temp.
Resolution
Electr. output
Operating voltage
Ambient temp.
Dimensions
Display
Power supply unit
Weight
9.1700.98.000
See page 28
95 x 155 x 35 mm
65 x 100 x 55 mm
0.23 kg; 0.51 kg
Wind
Precipitation, Brightness, Temperature, Air humidity
Description
Order-No.
Clima Sensor 2000
Technical Data
Clima Sensor 2000
WNHTF
4.9010.00.061
X
Precipitation
X
Clima Sensor 2000
WNH
4.9000.00.061
X
X
X
Clima Sensor 2000
NHTF
4.9011.00.061
X
X
Clima Sensor 2000
NH
4.9001.00.061
X
X
The Clima Sensor 2000
serves for the measurement of
important environmental data.
Depending on the type of
task it is available as combined
measuring instrument.
The analogue outputs are
configured as standard signals
so that they can be used for
the coupling on commercially
available bus systems.
Wind
Measuring range
Accuracy
Electr. output
Load
1 ... 40 m/s
± 0.5 m/s res. ± 5% of mr.
0 ... 10 V (= 0..40 m/s)
> 10 k
Precipitation
Measuring range
Electr. output
rain yes / no
0 V for rain,
10 V with dryness
fine drizzle
> 100 kW
approx. 3 rain particles
approx. 2 minutes
Wind
A cup star, the revolution-no.
of which is linear-proportional
to the wind speed, supplies
a frequency through a Reedcontact to a connected
frequency-voltage-converter.
The frequency is dependent
on the revolution number.
Wind
Sensitivity
Load
Switch-on-delay
Switch-off-delay
Brightness
Brightness
X
TempeAir
rature humidity
X
X
X
X
Load
0 ... 100 k Lux
700 ... 1050 nm
± 10 % of measuring
value
3 x 0 ... 10 V, Eastern
Southern and Western
direction
> 10 k
Measuring range
Spectral range
Accuracy
Electr. output
Precipitation
The detection is carried
out optically acc. to the reflection-method with modulated
infrared-light on precipitation
particles.
Temperature
Measuring range
Measuring
element
Accuracy
Electr. output
Load
- 20 ... + 60 °C
Pt100 acc. to IEC 751
1/3 DIN class B
± 0.15 °C at 0 °C
0 ... 10 V
> 10 k
Brightness
The brightness is detected by
means of three independent
photo-diodes which are arranged in 90°-segments. Three
independent output voltages
are linear to the brightness.
Air humidity
Measuring range
Accuracy
0 ... 100 % rel. humidity
± 3 % in the range
10 ... 90 % rel. F.
0 ... 10 V
> 10 k
Temperature
The temperature sensor
is a standardised resistance
thermometer – Pt 100 – of
long-term stability.
Air humidity
The measurement is carried
out with a capacitive humidity
sensor changing its capacity
according to the relative
humidity.
Electr. output
Load
General
Operating voltage 24 V AC ±15%
24 V DC ±25%
Current consumpt. < 100 mA
- 40 °C... + 60 °C
Ambient temp.
Connecting cable 10 m ; LiYCY
12 x 0.14 mm2,
uv-resistant
max. 100 m at a supply
with nominal 24 V
Mounting
retaining clamp, stainless
steel, for mast or wall
Weight
max. 1.5 kg
21
Wind
Measuring Transformers
Description
Order-No.
Technical Data
Measuring Transformers
Measuring
Transformer WS
Instantaneous value
The speed-dependent frequency generated by the wind
transmitters is converted into a
current or voltage signal. This
allows the control of connected
recording, display or switching
devices.
Suitable for wind transmitters
4.331.3x.000
4.3303.22.000 / 007
4:3303.22.008 / 018
4.3339.xx.xxx
4.3340.xx.xxx
.00...
.10...
.040
Electr. output
0 ... 240 Hz, 15V
3... 1042 Hz, 15V
Model
Electr. output
.041
.060
.061
.080
.081
.100
.101
Measuring value
Operating voltage
Ambient temp.
Protection
Dimensions
Wall mount. case
PC-board
Weight
Wall mount. case
PC-board
Measuring
Transformer WSM
Mean value
The speed-dependent frequency generated by the wind
transmitters is totalled up over
the selected integration time
and, as a mean value, converted into a current or voltage
signal. This allows the control
of connected recording, display
or switching devices.
Suitable for the wind transmitters of the classic-line with
frequency output
4.3303.22.000 / 007
4.3303.22.008 / 018
4.3341.xx.xxx
.00...
.10...
.040
Model
Electr. output
.041
.060
.061
.080
.081
.100
.101
Electr. input
Measuring value
Measuring range
Time of integration
Operating voltage
Ambient temp.
Protection
Dimensions
Wall mount. case
PC-board
Weight
Wall mount. case
PC-board
22
Measuring range
0 ... 20 m/s
0 ... 40/50/75 m/s
wall mounting case
pc-board
0 - 20 mA
(max. 600 )
4 - 20 mA
(max. 600 )
0 - 1 V (max. 10 mA)
0 - 10 V (max. 10 mA)
0 - 20 mA / 0 - 1 V
0 - 20 mA / 0 - 10 V
4 - 20 mA / 0 - 1 V
4 - 20 mA / 0 - 10 V
instantaneous value
230 V / 50 Hz
0 ... +40°C
IP 65
(wall mounting case)
200 x 120 x 75 mm
170 x 100 x 30 mm
0.65 kg
0.25 kg
Wall mounting case
PC-board
0 - 20 mA
(max. 600 )
4 - 20 mA
(max. 600 )
0 - 1 V (max. 10 mA)
0 - 10 V (max. 10 mA)
0 - 20 mA / 0 - 1 V
0 - 20 mA / 0 - 10 V
4 - 20 mA / 0 - 1 V
4 - 20 mA / 0 - 10 V
0 ... 1042 Hz (50 m/s)
mean value
selectable in 5 m/ssteps up to 50 m/s
2.5/ 5 / 10 / 15 /
30 / 60 / 120 min,
selectable
230 V / 50 Hz
0 ... +40°C
IP 65
(wall mounting case)
200 x 120 x 75 mm
170 x 100 x 30 mm
0.7 kg
0.3 kg
Wind
Measuring Transformers
Description
Order-No.
Digital-AnalogTransducer TW
4.3348.xx.xxx
.00.
.10.
.040
mean value
The pulses from wind sensor
4.3308.10.000 are converted
by the measuring transducer
into standardized analogue
output signals.
These output signals are
available
1. as direction-dependent or
2. as direction-independent
value.
Electr. output
.060
.061
Measuring value
Measuring range
codable
Time of integration
codable
Relays-delay
Relay-load
■ Measuring range adaptation
■ Delays for analogue signals
■ Relay-output delay for dampening of switching processes in case of short-time
flow-turbulence.
Suitable Wind transmitters:
4.3519.x0.x00 / 4.3129.0x.x00
Model
.041
Moreover, the following settings can be effected through
the coding switch:
Windinterface
Technical Data
Electr. input
Operating voltage
Ambient temp.
Protection
Dimensions
Wall mounting case
PC-board
Weight
Wall mounting case
PC-board
4.4070.01.00x
4.4070.01.70x
x
Electr. output
Telegram variant
Input
The wind interface transforms
the digital signals of the wind
speed- and wind direction
transmitters into serial data
telegrams. The interface allows
the connection to different
instruments, thanks to the
interface variants available and
the possibilities of forming the
data telegram.
WS
WD
wall mounting case
PC-board
0 - 20 mA
(max. 600 Ω )
4 - 20 mA
(max. 600 Ω )
0 - 1 V (max. 10 mA)
0 - 10 V (max. 10 mA)
mean value
6 values up to 50 m/s,
5; 10; 20; 30; 40;
50 m/s
24; 48; 120; 240 s
codable, 1.5 ... 45 s
max. 200 W / 220 V /
8A
2 x 15 V pulse
230 V / 50 Hz
0 ... +40°C
IP 65
(wall mounting case)
200 x 120 x 75 mm
170 x 100 x 30 mm
0.65 kg
0.25 kg
Fibre-optic-interface
RS 422
On request
0...713 Hz (50 m/s)
5-bit serial
synchronous
Measuring value
1 s instantaneous
value for WS and WD
Operating voltage
Protection
Dimensions
Weight
24 V AC/DC ± 15 %
IP 65
84 x 179 x 67 mm
0.85 kg
The voltage supply of the wind
transmitter is effected via the
wind interface. The housing is
made of aluminium, and is suited for outside mounting.
For wind transmitters:
4.3518.0x.x00 / 4.3128.xx.xx0
4.4071.01.xxx
Input
WS
WD
0...648 Hz (50 m/s)
4-bit serial parallel
For wind transmitters:
4.3303.22.000 /
4.3125.32.100
4.4072.01.xxx
Input
WS
WR
0...1042 Hz (50 m/s)
8-bit serial
synchronous
Mounting Set compact
506614
Clamping range
Material
Weight
Mounting clamp with straps to
mount the wind interface onto
masts
Ø 48 ... 102 mm
stainless steel
0.18 kg
23
Wind
Indicators, Recorder, Software
Description
Order-No.
Technical Data
Indicators, WS
Digital Indicator WG
for panel mounting
Flat-section indicator for the
display of wind speed values.
The background of the indicator
is black to facilitate reading of
the red digits.
Preferably switch panel or front
panel mounting
Digital Indicator WG
for panel mounting
with 2 adjustable limit contacts
Flat-section indicator for the
display of wind speed values.
Two setting knobs on the front
panel serve for setting the two
potential-free relay-contacts.
LED-digits show the switching
functions.
The background of the indicator
is black to facilitate reading of
the red digits.
Preferably switch panel or front
panel mounting.
Indicator
Analogue indicator for the
direct connection to the
Wind Transmitter (small
model),
order-no. 4.3400.30.000
24
4.1044.00.xxx
.000
.040
.041
.061
Electr. Input
Display range
Resolution
Display
Operating voltage
Model
Protection
Dimensions
Weight
4.1045.00.xxx
.000
.040
.041
.061
Electr. Input
Display range
Resolution
Display
Contact
Operating voltage
Model
Protection
Dimensions
Weight
4.3421.00.000
Display range
Division
Electr. input
Model
Protection
Class
Dimensions
Weight
0 ... 834 Hz
0 ... 20 mA
4 ... 20 mA
0 ... + 10 V
0 ... 40.0 m/s , or
depending on sensor
type
± 1 digit
LED, red, 13 mm high
230 V / 50 Hz
switch panel mounting
IP 20
96 x 48 x 104 mm
0.3 kg.
0 ... 834 Hz
0 ... 20 mA
4 ... 20 mA
0 ... + 10 V
0 ... 40.0 m/s, or
depending on sensor
type
± 1 Digit
LED, red, 13 mm high
throw-over-switch
230 V / 50 Hz
switch panel mounting
IP 20
96 x 48 x 104 mm
0.3 kg
0 ... 35 m/s
0 ... 65 kn
0 ... 12 Beaufort
2 m/s
5 kn
0 ... 1 mA DC
wall mounting case
IP 65
2
122 x 120 x 85 mm
0.55 kg
Wind
Indicators, Recorder, Software
Description
Order-No.
Technical Data
4.1044.10.xxx
.040
.041
.061
Display range
Electr. input
Indicators, WD
Digital Indicator WD
for panel mounting
Flat-section indicator for
display of wind direction
values.
The background of the
indicator is black to facilitate
reading of the red digits.
Preferably switch panel or
front panel installation.
Resolution
Display
Operating voltage
Model
Protection
Dimensions
Weight
0 ... 360°
0 ... 20 mA
4 ... 20 mA
0 ... + 10 V
± 1 digit
LED, rot, 13 mm high
230 V / 50 Hz
switch panel mounting
IP 20
96 x 48 x 104 mm
0.3 kg
Combined
Indicators WS/WD
Combined Indicator
4.3228.30.000
Digital indicator which indicates wind direction in a circle of
red LED’s and wind speed in
digits in the centre of the circle.
Yellow scale inscription on
black background.
Resolution
Display
Suitable measuring
transmitters of the Small
Wind Transmitters-Line:
Small Wind Transmitter
4.3515.30.000
Wind direction transmitter
4.3127.40.000
Combined Indicator
Digital indicator which indicates wind direction in a circle of
red LED’s and wind speed in
digits in the centre of the circle.
Yellow scale inscription on
black background.
Suitable measuring transmitters of the compact-line :
Wind transmitter
4.3518.00.000
Wind direction transmitter
4.3128.00.000
Display range
Operating voltage
Model
Protection
Dimension
Weight
4.3228.40.000
Display range
Resolution
Display
Operating voltage
Model
Protection
Dimensions
Weight
0 ... 99.9 m/s, or
0 ... 99.9 kn
0 ... 360°
0.1 m/s resp. kn
22.5°
3-digits LED
7 segment red, 8 mm
high
16 LED bars, red
230 V / 50 Hz or
11 - 24 V DC
switch panel mounting
IP 42
96 x 96 x 110 mm
0.6 kg
0 ... 99.9 m/s, or
0 ... 99.9 kn
0 ... 360°
0.1 m/s resp. kn
22.5°
3-digits LED
7 segment red,
8 mm high
16 LED bars, red
220 V / 50 Hz or
12 - 24 V DC
switch panel mounting
IP 42
96 x 96 x 110 mm
0.6 kg
25
Wind
Indicators, Recorder, Software
Description
Order-No.
Technical Data
Wind Display
4.3250.xx.000
.00...
Operating voltage
Digital indicator for the display
of wind speed and wind direction.
.01...
Indicates the wind direction in
a circle of 72 LED luminous
bars, and the speed by 7-segment-LEDs.
In addition, the minimum and
maximum wind speed values
can be indicated by two other
digit displays.
Display options of
the WS:
- instantaneous value
or
- 2 min. means value and
maximum value
or
- 10 min. mean value and
maximum value
Display options of
the WD:
- instantaneous value
or
- 2 min. mean value and
variation
or
- 10 min. mean value and
Variation
The calculation of the mean
values and maximum values is
carried out according to the
ICAO.
A built-in RS-422-interface facilitates the connection of other
wind indicators LED:
Suitable wind transmitters:
4.3303.22.000 / 008
4.3125.32.100
4.3336.31.000
4.3350.00(10).000
4.3800.00(20).xxx
4.3519.00.000
4.3129.00.000
26
Display range
Wind speed
Direction
Resolution
Wind speed
Wind direction
230 V / 50 Hz;
24 V AC;
12 V –35 V DC
115 V / 50 Hz;
24 V AC;
12 –35 V DC
0...99.9 / 0…999
m/s / kt / km/h / Bft
0...360°
0.1 / 1
5°
Wind transmitter input
WS
0...1600 Hz
WD
Thies- synchronous
serial
or
serial data telegram
WD + WS
via RS 422
Interface
RS 422
Connection
Ambient temp.
Model
Protection
Dimensions
Weight
EMC
Screw terminal
-10...+50°C
switch panel mounting
IP 50
144 x144 x135 mm
1.5 kg
EN 60945
EN 61000-6-2
EN 61000-6-3
Wind
Indicators, Recorder, Software
Description
Order-No.
Technical Data
Wind Display LED
4.3251.xx.000
.00...
Operating voltage
- Ship version Digital display instrument which
indicates the wind speed and
wind direction.
Indicates the wind direction in a
circle of 72 LED luminous bars,
and the speed by 7-segmentLEDs.
.01...
Display range
Wind speed
Direction
Ship version with direction
circle
divided in red and green LED’s
according to port side and starboard.
Resolution
Wind speed
Wind direction
When using a suitable sensor
electronics the display of
the “true” wind values is
possible.
A built-in RS-422-interface
facilitates the connection of
other wind indicators LED
Wind Display LED
True =
real wind speed
and wind direction
Relative = seeming wind speed
and wind direction
Data from the wind transmitter
and data, according to NMEA
0183, coming from a compass
system (ship heading “Gyro”)
and the ship speed (LOG), are
used to calculate the “true”
wind-values via a built-in
RS422 interface.
The selection for displaying the
“true” or “relative” wind values
is done through the mode-key
on the front side.
0.1 / 1
5°
Interface
Data telegram
1 x RS 422
LED-standard
ultrasonic
NMEA 0; NMEA 1
Connection
Ambient temp.
Model
Protection
Dimensions
Weight
EMC
Screw terminal
-10...+50°C
switch panel mounting
IP 50
144 x144 x135 mm
1.5 kg
EN 60945
EN 61000-6-2
EN 61000-6-3
Interface
4 x RS 422
Suitable wind transmitters:
4.3303.22.000 / 008
4.3125.32.100
4.3336.31. 001
4.3350.00(10).000
4.3800.00(20).xxx
For the display of “true”
and “relative” wind values.
0...99.9 / 0…999
m/s / kn / km/h / Bft
0° - 180° - 0° (0...360°)
Wind transmitter input
0...1600 Hz
WS
Thies- synchronous
WD
serial
or
Serial data telegram via
WD + WS
RS 422
Display of WS:
- instantaneous value
Display options of the WD:
- instantaneous value or
delayed
or
- instantaneous value and variation
or
- delayed and variation
- Ship version -
230 V / 50 Hz;
24 V AC;
12 V –35 V DC
115 V / 50 Hz;
24 V AC;
12 –35 V DC
4.3251.xx.001
Meas. value input
WS
WD
or
WD + WS
and
LOG + Gyro
0...1600 Hz
Thies- synchronous
serial
Serial data telegram
via RS 422
Serial data telegram
acc. to NMEA 0183
(DM)
Other techn.
data see above
29
Wind
Indicators, Recorder, Software
Description
Order-No.
Technical Data
9.3392.10.040
9.3393.10.040
9.3395.10.040
Number of channels
Recorder
Continuous Line Recorder
Designed for the continuous
recording and the direct
reading of wind measuring
values.
Instrument as switchpanel-installation housing.
Identification of individual
channels by different colour
pens.
Recorder Roll
Model
Operating voltage
Ambient temp.
Type of protection
Dimensions
Weight
1
2
3
0 ... 20 mA / 0 ... 10 V
class 0.5
blue, red, green
100 mm
20, 60, 120,
240 mm/h
switch-panel-mounting
230 V / 50 Hz
0 ... +50°C
IP 54 or IP 20
144 x 144 x 295 mm
6.2 kg
205434
Roll length
32 m
205433
205432
205431
Colour
blue ( 1. channel )
red ( 2. channel )
green ( 3. channel )
9.1700.98.000
Connectable
Thies instruments
Wind Interface
Wind Display
Datalogger
4.4070.01.706
4.3250.xx.000
9.1740.xx.x1x
US-Anemometer
4.3800.xx.xxx
4.3810.xx.xxx
Meteo comp
4.3329.00.000 with
9.3229.00.000
Illustration
numerals
diagram
wind rose
time
date
Wind direction
instantaneous value
variation
mean value, gliding
Wind speed
instantan, value 1 s
mean value, gliding
min. and max. value
Time intervals
1, 2, 10, 30, 60 min.
for mean values
Electr. input
Accuracy
Print colour
Recording width
Paper advance
Recording chart in roll format
for the above line recorder.
Felt Pen
Spare pens for identification
of the different channels for
above line recorder.
Software
Meteo-Online
The software Meteo-Online is a
WINDOWS Program, compatible
to WINDOWS 98 / NT / 2000 /
ME/XP.
It serves for the visualisation
and documentation of meteorological measuring values.
The visualisation is carried out
alternatively in graphical form
as diagram and/or with text.
The user has the possibility
to place the display-elements
free on the screen.
The documentation can be
recorded in hour’s- or day’s
files with selectable averaging
periods for the respective
parameters. The documentation files are ASCII-files, and
can be imported, for example,
directly into EXCEL. All THIESinstruments with serial data
output can be connected via
the serial interface of a PC.
According to the number of
serial interfaces it is possible
to administrate several
instruments at the same time.
The Client Server Concept offers
the possibility of documenting
data in the background without
active visualisation
9.1700.98.100
30
Description and data same as above,
however with data monitor for checking
the incoming measuring values additionally
on threshold values or alarm parameters.
Wind
Wind Alarm
Description
Order-No.
Wind Alarm Unit 2
Triggers a threshold value
contact for a set velocity value.
There are two LEDs on the front
plate which indicate the operational control and the switching
status of the alarm threshold.
The delay times, the switching
point and the measuring intervals can be set by means of the
rotary switch on the front
panel.
There is a code switch to set
the following wind transmitter
models:
4.3303.22.000
4.3515.30.000
4.3515.50.000
4.3518.00.000
4.3519.00.000
4.3520.00.000
4.3241.00.000
.00.001
.02.000
.02.001
.03.000
Wind Alarm Unit 3
4.3242.01.000
Operating voltage
230 V / 50 Hz
230 V / 50 Hz
24 V AC/DC
24 V AC/DC
12 V AC/DC
Alarm range
Resolution
Electr. input
Switching point
Switch-on-delay.
Switch-off-delay.
Measuring interval
Relay output
Contact load
Ambient temp.
Operating voltage
Protection
Dimensions
Weight
For the display of the current
wind speed values and for
triggering a threshold value
contact.
Switches on the front plate
for setting the switching point
and the switch-on/switchoff-delays.
Suitable wind transmitter
Best.-Nr. 4.3303.22.000
Wind Alarm Unit 4
Technical Data
Measuring range
Electr. input
Display
Contact load
Switching point
Switch-on delay
Switch-off delay.
Operating voltage
Protection
Dimensions
Weight
4.3242.02.000
For digital display of the
current wind speed value.
Triggers two threshold value
contacts, for example early
warning and main alarm.
Switches on the front plate
for setting the switching
points and the switchon/switch-off-delays.
Instrument with integrated
power supply unit for the
supply of the wind transmitter
heating.
Measuring range
Electr. input
Display
Contact load
Switching point
Switch-on delay.
Switch-off delay.
Operating voltage
Protection
Dimensions
Weight
incl. supply for heating
w/o supply for heating
incl. supply for heating
w/o supply for heating
1 ... 39 m/s
0.1 m/s
see models
selectable in 1 m/s
1 - 9 s resp. 2 – 18 s
1 - 9 resp. 2 - 18 min.
depends on time
intervals
1 s or 2 s selectable
change-over switch,
one-pole
200 W / 24 V DC
100 W / 250 V DC
1000 VA, max. 8 A
-25 - + 55 °C
230 V / 50 Hz
IP 65
200 x 120 x 75 mm
1 kg
0 ... 50 m/s
0 ... 1042 Hz
00.0 ... 99.9 m/s
200 W / 24 V DC
100 W / 250 V DC
2000 VA, max. 8 A
0 ... 50 m/s, selectable
0 - 18 s,
in 9 steps
0 - 18 min., in 9 steps
230 V / 50 Hz
IP 65
200 x 120 x 75 mm
1 kg
0 ... 50 m/s
0 ... 1042 Hz
00.0 ... 99.9 m/s
200 W / 24 V DC
100 W / 250 V DC
2000 VA, max. 8 A
2 x 0 - 50 m/s,
selectable
2 x 0 - 18 s, in 9 steps
2 x 0 - 18 min, in 9
steps 230 V / 50 Hz
IP 65
230 x 300 x 85 mm
2.6 kg
Suitable wind transmitter
Best.-Nr. 4.3303.22.000
Wind alarm units in combination with wind transmitters
trigger preventive measures to protect wind-endangered objects.
Applications:
■ cranes
■ masts
■ louvers and shutters
■ stages etc.
■ bridges
■ greenhouses
■ awnings
31
Wind
Masts and mechanical Accessories
Description
Order-No.
Technical Data
4.3187.11.000
Length
Diameter of tube
Material
Weight
2.5 m
48 mm
steel, galvanised
ca. 12 kg
4.3187.11.048
4.3187.11.060
Diameter of Tube
48 mm
60 / 48 mm
Length
Material
Weight
4m
steel galvanised
ca. 10 kg
Length
4m
6m
10 m
Weight
21 kg
29 kg
44 kg
Material
Top of mast
Inserted length
Staying
Wind stress
al, sea-water-proof
Ø 49 mm
approx. 1.5 m
three-fold (4 m, 6 m)
six-fold (10 m)
max. 60 m/s
Suitable for
4 m mast
6 m mast
10 m mast
Gripping diameter
60mm
80 mm
90 mm
Weight
4.5 kg
4.3179.30.080
4.3180.30.090
4.3181.30.116
Length / weight
4 m 15 kg
6 m 16 kg
10 m 43 kg
4.3181.30.132
12 m
Diameter of tube
80/71 mm
90/80/71 mm
116/102/90/80/
71 mm
132/116/102/90/
80/71 mm
Instrument Holders
Instrument Holder
For field installation of
meteorological measuring
instruments.
Consisting of mast tube,
mounting cross, earth pins for
ground installation or dowel
pins for fundament as well as
a staying and earth clamp.
Instrument Holder
For the mounting of meteorological measuring instruments in
buildings.
For wall mounting consists of
mast tube, 2 wall clamps and
an earth clamp.
Telescopic Mast
for Field Installation
Telescopic Mast
For the field installation of
meteorological measuring
instruments. Mast with staying,
base plate and adaptor.
The base plate has a tilting
mast receptacle.
4.3179.00.000
4.3180.00.000
4.3181.00.000
Grounding Set
To ground the preceding telescope masts. Consists of a mast
ground clamp, a cross-bar, 2m
long, and a CU wire Ø 5 mm,
1 m long.
4.3186.00.000
4.3186.00.001
4.3186.00.002
Telescopic Mast
without Staying
Telescopic Mast
For the mounting of meteorological measuring instruments.
This telescopic mast can be
used in the open country, in
combination with a respective
tilting device, without staying.
67 kg
Top of mast
Material
30
Ø 71 mm
aluminium
Wind
Masts and mechanical Accessories
Description
Order-No.
Technical Data
4.3181.03.080
.090
.116
.132
Suitable for
4.3179.30.080
4.3180.30.090
4.3181.30.116
4.3181.30.132
Tilting Devices
Tilting Device
For field mounting on fundament
The tilting device serves as
stand for a telescopic mast.
Telescopic mast and tilting
device are free-standing, and
do not need any staying.
For maintenance purpose the
telescopic mast can be tilted
by means of a rope winch
(optional accessory).
Height
Material
Weight
Tilting Device
For wall mounting
The tilting device serves as
wall mounting device for a
telescopic mast.
For maintenance purpose the
telescopic mast can be tilted
by means of a rope winch
(optional accessory).
4.3181.13.080
4.3181.13.090
4.3181.13.116
4.3181.13.132
Type: LMB 80/90/116/132
For wall mounting of the
telescopic mast.
210363
210364
211278
210368
Mast Ground Clamp LE
Clamp to be mounted at the
mast foot for grounding the
mast by means of a wire with
diameter up to 9 mm.
Adaptor
Type: LRD 71-50 A-6/16
Suitable for
4.3179.30.080
4.3180.30.090
4.3181.30.116
4.3181.30.132
Material
Weight
Mast Mounting Clamp
210457
210458
211279
210460
211545
1580 mm
steel, galvanised
60 kg
Steel, galvanised
32 kg
Suitable for
4.3179.30.080
4.3180.30.090
4.3181.30.116
4.3181.30.132
Diameter
Material
Weight
80/90/116/132 mm
aluminium
0,5 / 0,7 / 1,3 / 1,5 kg
Suitable for
4.3179.30.080
4.3180.30.090
4.3181.30.116
4.3181.30.132
Gripping diameter
80 mm
90 mm
116 mm
132 mm
Material
Weight
aluminium
ca. 0.13 kg
Material
Weight
aluminium
1 kg
Serves for reducing the
diameter of the mast end
tube from 71 mm to 50 mm so
that Classic-wind transmitters
or US-Anemometers can be
mounted directly onto the
mast top.
31
Wind
Masts and mechanical Accessories
Description
Order-No.
Technical Data
4.3170.00.xxx
....000
....001
....003
Wind Transmitt.
4.3303.22.000
4.3303.22.000
4.3105.22.000
Wind Direc. Transm.
4.3120.22.018
4.3121.32.000
4.3120.22.018
Material
Tube dimensions
steel, galvanised
1 1/2“ n. DIN 2448
(Ø 48.3 x 2.6 mm)
Ø 50 x 74 mm
Traverses
Traverse
for Classic Wind Transmitters
For mounting the wind speed
transmitter and wind direction
transmitter jointly onto a mast.
The traverse is connected with
plug according to the transmitter combinations.
Fixing boring
Horizontal
Sensor distance
Vertical
Sensor distance
Total height
Weight
Traverse
4.3173.01.001
for Classic Wind Transmitters
Fixing boring
HorizontalSensor distance
Vertical
Sensor distance
Total height
Weight
For mounting the wind speed
transmitter and wind direction
transmitter jointly onto a mast.
With boring for mounting the
lightning rod 4.3100.99.001
Traverse
For mounting the wind speed
transmitter and wind direction
transmitter jointly onto a mast.
34
0.8 m
Clamping range
Sensor distance
Material
Traverse
Gripping clamp
Weight
Ø 30 ... Ø 50 mm
0.5 m
Clamping range
Ø 48 ..... Ø 102 mm
Ø 116 ... Ø 200 mm
0.8 m
4.3171.30.000
.31.
Sensor distance
Material
Traverse
Mounting set
Weight
For mounting the wind speed
transmitter and wind direction
transmitter jointly onto a mast.
For Wind Transmitters compact
0,02 m
0.71 m
3 kg
4.3171.20.000
For mounting the wind
transmitter and wind direction
transmitter jointly onto a mast.
Traverse, short
0.6 m
0.6 m
approx. 400 mm
650 mm
Ø 40 ... Ø 80 mm
aluminium
2.8 kg
For Small Wind Transmitters
for Wind Transmitters compact
aluminium, anodised
DIN 2448
(Ø 48.3 x 2.6 mm)
Ø 71 x 74 mm
Sensor distance
Vertic. Sensor distance
Total height
Mast clamp
Material
Weight
For mounting the wind speed
transmitter and wind direction
transmitter jointly onto a mast.
Traverse
0.02 m
0.71 m
6.8 kg
4.3172.00.000
for Classic Wind Transmitters
Traverse
Material
Tube dimensions
0.6 m
4.3171.40.000
.41.
Clamping range
Sensor distance
Material
Traverse
Mounting set
Weight
aluminium
stainless steel
0.35 kg
aluminium
stainless steel
0.35 kg
Ø 48 ..... Ø 102 mm
Ø 116 ... Ø 200 mm
0.8 m from mast
aluminium
stainless steel
0.30 kg
Wind
Masts and mechanical Accessories
Description
Order-No.
Technical Data
Lightning Rod / Hangers /
Holders / Adaptors
Lightning Rod
Length
Height
Material
Weight
To be mounted additionally at
the telescopic mast, tube or
traverse. Protects the wind
transmitter against damages
caused by lightning strokes.
Suitable for:
Mast or tube with Ø 50 mm
Mast or tube with Ø 50 mm
Mast or tube with Ø 71 mm
Traverse: 4.3173.01.001
Traverse:
4.3171.30/31/40/41…
Hanger, 1 m
Hangers are used to mount
wind measuring instruments to
telescope masts. The extension
is 1 m from the mast. The outer
end has a holder especially
designed for the respective
data transmitter.
Mounting by bolting connecting clamps or mast clamps.
Holder compact
4.3100.99.000
4.3100.99.150
4.3100.99.170
4.3100.99.001
506351
4.3185.xx.003
...00....
...01....
...02....
Tube diameter
Clamp range
Material
Weight
50 mm
for telescopic masts
aluminium
1.8 kg (hanger 1 m)
506347
Material
Clamp range
Dimensions
Weight
stainless steel
Ø 35 – 50 mm
80 x 150 mm
0.35 kg
507620
Material
Weight
aluminium
1 kg
506283
Material
Dimensions
Weight
aluminium, anodised
Ø 50 x 40 mm
0.5 kg
506614
506971
Clamping range
Ø 48 –102 mm
Ø 116 –200 mm
Stainless steel
0.18 kg
The adaptor is used to mount
wind measuring instruments
of the compact-series to a
1"- tube.
Mounting Set compact
Mounting holder with straps
for mounting of power supply
units, connection boxes
compact, and wind interfaces
onto masts or tubes.
2,4 kg
4 kg
4 kg
2 kg
0,34 kg
60-132 mm
40- 80 mm
48- 50 mm
Serves as reducing unit for
mounting the wind transmitters
of the First Class type onto
a traverse tube of a diameter
Ø 50 mm.
Adaptor 1"
800 mm steel,galvanised
1500 mm steel,galvanised
1500 mm steel,galvanised
1500 mm aluminium
560 mm stainless steel
Clamp range
Serves for mounting the wind
transmitter compact onto a
mast tube.
Adaptor 1 "/ 1 1/2"
560 mm
560 mm
560 mm
400 mm
----
Material
Weight
Please contact us for other accessories, such as cables and cable
connections as well as for additional constructions of masts or systems.
35
Wind
power supplies
Description
Order-No.
Technical Data
9.3388.00.000
Primary
Secondary
Power Supply
Power Supply Unit
For the power supply of wind
speed transmitters, wind
directions transmitters or
combined instruments.
The outputs are each
protected by fuses.
The housing is made
of plastic fibre.
Protection
Dimensions
Weight
230 V / 50/60 Hz
26 V AC / 3.46 A
24 V AC / 0.5 A
12 V DC / 0.3 A
IP 65
125 x 125 x 125 mm
2.5 kg
Suitable for:
Wind transmitter type: Classic
Power Supply Unit
compact
9.3389.10.000
For the power supply of wind
speed transmitters, wind
direction transmitters or
combined instruments.
Primary voltage
Secondary voltage
Terminal strip
Housing
Protection housing
Dimensions
Weight
With integrated terminal
strip for the connection and
distribution of the cables.
The primary and secondary
voltages are protected by
safety fuses.
230 V / 50/60 Hz /
0.48 A
2 x 24 V AC / 20 VA
1 x 24 V AC / 5 VA
1 x 24 V AC / 70 VA
1 x 24 V DC / 2 W
20-pole
plastic fibre
IP 65
190 x 280 x 130 mm
4.2 kg
Suitable for:
Wind transmitter type: Classic
: Compact
Connection Box 1
compact
9.3199.00.100
Primary voltage
Secondary voltage
For the power supply of wind
speed transmitters, wind directions transmitters or combined
instruments.
Terminal strip
Over-voltageprotection
Housing
Protection housing
Dimensions
Weight
With integrated over-voltageprotection (varistors). Can be
used also as junction box.
Suitable for:
Wind transmitter
type
: Classic
: Compact
Meas. value
sensor
: Clima - Sensor
2000
Connection Box 1
compact
9.3199.00.150
Primary voltage
Secondary voltage
Unit for the power supply of
the Ultrasonic Anemometer.
With integrated over-voltageprotection (varistors). Can be
used also as junction box.
More power supply units and connection
boxes on request.
Terminal strip
Over-voltage- protection
Housing
Protection housing
Dimensions
Weight
230 V / 50/60 Hz
2 x 24 V AC / 20 VA
1 x 24 V AC / 70 VA
or
1 x 24 V AC / 20 VA
1 x 24 V AC / 70 VA
1 x 24 V DC / 1.5 W
14-pole
all connections
aluminium
IP 65
160 x 260 x 90 mm
4.5 kg
230 V / 50/60 Hz
2 x 24 V AC / 20 VA
1 x 24 V AC / 70 VA
or
1 x 24 V AC / 20 VA
1 x 24 V AC / 70 VA
1 x 24 V DC / 1.5 W
14 pole
all connections
aluminium
IP 65
160 x 260 x 90 mm
4.5 kg
as versatile as require
the international tasks
Weather and Environmental
monitoring Technology
Worldwide
Climatic measurement and
intelligent analysis are
international tasks. They do
not only demand a worldwide
cooperation of the responsible
authorities, but also a
comprehensive network of
sensors and analytical systems.
We have developed a smoothly
functioning system of partners
and subsidiaries throughout
the world to provide expert
advice there where you need it.
Europe:
Austria
Belgium
Denmark
Finland
France
Greece
Italy
Netherland
Norway
Portugal
Spain
Sweden
Switzerland
Turkey
United Kingdom
Overseas:
ENERCORP instruments ltd
25 Shorncliffe Rd
Toronto, ON, M9B 3S4
Canada
Phone (416)231-5335
Fax
(416)231-7662
E-Mail info[email protected]
www.enercorp.com
DIN EN ISO 9001
Certificate: 08/100/1688
010129/08/03
Argentina
Australia
Brasil
Canada
Columbia
Chile
Ecuador
Egypt
Hongkong
India
Indonesia
Malaysia
Marocco
Peru
Saudi Arabia
South-Africa
Syria
Venezuela
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project