Line Seiki | M13-210 Watchdog Timer. M13

MIERUZZO SERIES MANUAL MIERUZZO SERIES MANUAL ■ M13-212(Logic Filter) MIERUZZO ACCESSORY UNIT Instruction Manual ● Parts ● Operation Input Status Display OUT SET Preset Display 4 3 L3 L2 2 Press 4 again. Preset digit 4 will change display to "H". 1 Press 1 . Preset digit 1 will be selected and start to blink. 1 Press 1 again. Preset digit 1 will change display to "H". Key Protect Function L1 1 4 ・When Key Protect (K / P) terminal is connected to GND, Key Operation is disabled. ・Make sure to disconnect Key Protect (K/ P) terminal from GND before attempting Key Operation. Setting Keys Terminal Label Terminal 10 18 Preset Logic will be confirmed and saved when there is no key operation within 3 seconds. KEY/P… appears when Key Protect is activated OUT … appears when Input Logic matches Preset Logic ● Operation Example Pulse Input Logic1(Preset = "H") ・If Input Logic does not match Preset Logic, output is disabled. ※ Please set unused Logic inputs to "L". Logic2(Preset = "H") Logic3(Preset = "H") Logic4(Preset = "L") Pulse Output ● Wire Terminal Type: Screw Tightening(use AWG14-22 leadwires) Terminal Array ● Input Circuit Non-voltage Input(NPN Input) 4 ⑧ Logic 1 ⑦ Logic 2 INPUT GND 3 ⑥ Logic 3 ⑤ Logic 4 ② Key Protect 2 GND 1 GND ① Pulse Input <Reed Input> 5 6 7 8 <Open Collector> GND INPUT ※signal when contact is ON 9 GND ※ signal when transistor is ON <Voltage Input> ※ Terminals ③④⑨⑫⑬⑱ are connected internally. INPUT Input signal in ① will pass through as output signal ⑩. (when Input Logic matches Preset Logic) Connect ② to GND to disable Key Operation. Connect terminal ⑤⑥⑦⑧ to Input Logic signal. GND ATTENTION ● CUSTOMER SERVICE LINE SEIKI CO., LTD. Head Office E-mail URL 37-7 Chuo-cho, 2-Chome Meguro-ku Tokyo JAPAN 152-0001 TEL: 03-3716-5151 FAX: 03-3710-4552 [email protected] http://www.mieruzzo.com ■ MODEL・SPECIFICATIONS Model M13-210 M13-211 M13-212 Function Watchdog Timer Pulse Filter Logic Filter Display 4-Digit, 7-Segment LCD Digit Size:7mm Setting Range 00:01∼99:59 (mm:ss) 0.1∼999.9 (s) LLLL∼HHHH(16 possible logic) Input Pulse Input(Input) Disable(DIS) Key Protect(K/P) Pulse Input(Input) Key Protect(K/P) Pulse Input(Input) Logic1(Logic1) Logic2(Logic2) Input Type Non-contact / Reed Input: Open Collector Input L<2V(Sink Current approx. 1mA) Input Frequency 10Hz(Pulse Input) Output Non-contact Output:NPN Open Collector(DC30V 100mA max.) Relay Output:1c Contact(AC/DC30V 0.5A max.)(M13-210 only) Output Type Hold(Timer Stop Output) Output Delay 25msec Key Protect via Key Protect Input Memory EEPROM (10 years Data Retention; 10,000 Re-write Cycles) Power Supply DC12∼24V(-15% / +10%) Logic3(Logic3) Logic4(Logic4) Key Protect(K/P) 1kHz(Pulse Input) One-shot(100ms) Hold(Logical Match Output) approx. 0.4W(at DC24V) Power Consumption approx. 1.8W(at DC24V) Operating Humidity 45∼85%RH(non-condensing) Operating Temperature -10∼+50℃(non-freezing) Storage Temperature -20∼+60℃(non-freezing) Noise Immunity Square-wave Noise from Noise Simulator Power Supply Terminal: ±600V / Input Terminal: ±500V Vibration Resitance Malfunction: 10∼55Hz peak amplitude 0.15mm 3-directional 10 minutes Endurance: 10∼55Hz peak amplitude 0.375mm 3-directional 2 hours Weight approx. 130g Regulatory Compliance CE、RoHS approx. 110g ■ MOUNTING METHOD(via DIN Rail Size: 35mm) ■ DIMENSIONS(mm) [DIN Rail Mounting Method] 1. Hook Part A of the device to the top portion of the DIN rail, as shown in the figure below. 2. Plug-in Part B of the device. ※ signal when transistor is ON [DIN Removal Method] 1. Push Part C of the device using a screw driver, as shown in the figure below. 2. Remove the device from the DIN rail. 90 Terminal Array A Non-contact Output + − Apply DC12V B 5 GND GND 10 11 12 13 14 15 16 17 18 O.C. Output・Power Thank you for purchasing our product, M13-210/211/212. Please read this instruction manual carefully to ensure correct usage of this device. Please keep this instruction manual for future reference. Timing Diagram Logic Filter (input logic match output) This device monitors the input pulse, and passes it through as an output only when Input Logic matches Preset Logic. Input M13-210 WATCHDOG TIMER M13-211 PULSE FILTER M13-212 LOGIC FILTER ・ Do not use this device near machines that emit strong electromagnetic field or objects that store static electricity. ・ Do not drop or subject this device to strong impact. ・ Do not use or store this device where it will be exposed to water or in places with wet conditions. ・ Do not use or store this device where it can be exposed to direct sunlight, dust, high temperature, and high humidity. ・ Do not attempt to disassemble or modify this device. ・ Do not use organic solvents such as thinners etc., for they will damage the external finish. Please note that misuse of this device may lead to injury to the user or damage to the device. Please observe all safety precautions and warnings in this instruction manual. 76 L4 4 . Preset digit 4 will be Press selected and start to blink. 4 Each digit of Preset Logic is entered by corresponding keys. Pressing ①∼④ will select the corresponding digit and make it blink. While blinking, the logic of the digit can be changed between "L" and "H". When no change is made after 3 seconds from last operation, Preset Logic is confirmed and blinking stops automatically. Terminal Label KEY/P To enter a Preset Logic to "HLLH": 1 ∼ 4 Terminal 1 9 STATE <Setting Example> ATTENTION 33 24V power to terminal No.17, 18. 52 ※ Terminals ③④⑨⑫⑬⑱ are connected internally. 57 When Input Logic matches Preset Logic, the output is the state of input terminal ①. C (DIN Rail Clip) This manual was last revised January 21, 2015. 4MWT002A Content is subject to change even without prior notice. All Rights Reserved, Copyright © 2015, LINE SEIKI CO.,LTD. -4- -1- MIERUZZO SERIES MANUAL MIERUZZO SERIES MANUAL ■ M13-210(Watchdog Timer) ■ M13-211(Pulse Filter) ● Parts KEY/P OUT Timer Display TIMER Preset Display SET min 3 3 Each digit of Preset Time is entered by corresponding keys. Pressing ①∼④ will select the corresponding digit and make it blink. While blinking, the value of the digit can be changed from "0" up to "9". When no change is made after 3 seconds from last operation, Preset Time is confirmed and blinking stops automatically. Terminal Label ● Parts ● Operation To enter a Preset Time of 1 min 30 sec: 1 ∼ 4 Terminal 1 9 4 <Setting Example> ● Operation 3 KEY/P OUT Timer Display TIMER Preset Display SET 2 Press 2 . Preset digit 2 will be selected and start to blink. (Upper row is Timer Display) 2 ×2 Press 2 again, twice. Preset digit 2 will increment twice and display "2". 3 Press 3 . Setting digit 3 will be selected and start to blink. 3 Press 3 again, 9 times. Preset digit 3 will increment 9 times and display "0". sec sec 2 Each digit of Preset Time is entered by corresponding keys. Pressing ①∼④ will select the corresponding digit and make it blink. While blinking, the value of the digit can be changed from "0" up to "9". When no change is made after 3 seconds from last operation, Preset Time is confirmed and blinking stops automatically. Terminal Label Press 3 again. Preset digit 3 will increment and display "1". To enter a Preset Time of 2.0s: 1 ∼ 4 Terminal 1 9 Press 3 . Preset digit 3 will be selected and start to blink. (Upper row is Timer Display) <Setting Example> 1 Setting Keys 2 Key Protect Function ・When Key Protect (K / P) terminal is connected to GND, Key Operation is disabled. ・Make sure to disconnect Key Protect (K/ P) terminal from GND before attempting Key Operation. Terminal Label Terminal 10 18 Press 2 . Preset digit 2 will be selected and start to blink. 4 2 ×2 KEY/P… appears when Key Protect is activated OUT … appears when Timer is stopped Key Protect Function Setting Keys ・When Key Protect (K / P) terminal is connected to GND, Key Operation is disabled. ・Make sure to disconnect Key Protect (K/ P) terminal from GND before attempting Key Operation. Terminal 10 18 KEY/P… appears when Key Protect is activated OUT … appears when Timer is started (100ms) Timing Diagram Pulse Filter (one-shot output) This device is a One-shot Timer for signal entering the Pulse Input. Multiple Pulse input received within a Preset Time (0.1s - 999.9s) will generate a one-shot pulse output. Pulse Input (Input) ×9 Preset Time will be confirmed and saved when there is no key operation within 3 seconds. Preset Time will be displayed on upper row as start of timer. ● Operation Example ・Timer is started when Input Pulse is received. While Timer is counting, Input Pulse is invalid. ・One-shot Pulse (100ms) is generated at the time the Timer is started. Disable (DIS) ・Timer is restarted for each input pulse received (when Disable Input is OFF). ・Timer is stopped when Preset Time is reached. ・Timer is stopped and Pulse Input is disabled when Disable Input is ON. ・Timer restarts when Disable Input is released (OFF). ・Control Output is set ON when Timer is stopped (Preset Time is reached). 1 Press 2 again, twice. Preset digit 2 will increment twice and display "3". Timing Diagram Watchdog Timer (continuous pulse monitoring) This device monitors the interval of input signal entering the Pulse Input via a Timer. If there is no signal received within the Preset Time, Timer is stopped and output signal is generated. By disabling input, forced start/stop of the Timer is possible. 2 Terminal Label Preset Time will be confirmed and saved when there is no key operation within 3 seconds. Timer will be displayed on upper row and start from "00:00". ● Operation Example 3 Pulse Input (Input) t=100ms t=100ms t=100ms t=100ms Control Output (Output) Preset Time Timer Control Output (Output) Preset Time Timer ● Wire Terminal Type: Screw Tightening(use AWG14-22 leadwires) ● Input Circuit Non-voltage Input(NPN Input) 7 8 9 Relay Output 1 INPUT 3 4 GND INPUT 5 6 7 8 9 INPUT Input signal detection in ① will start the Timer. Connect terminal ② to GND to disable Key Operation. ※ signal when transistor is ON 24V power to terminal No.17, 18. + − Apply DC12V 24V power to terminal No.17, 18. ※ Terminals ③④⑨⑫⑬⑱ are connected internally. ※ Terminals ③④⑨⑫⑬⑱ are connected internally. One-shot Pulse output (100ms) will be generated at the start of countdown timer. When Timer is stopped, output is set. (transistor output, relay output) -2- INPUT GND ※ signal when transistor is ON Terminal Array Non-contact Output GND <Voltage Input> ※ Terminals ③④⑨⑫⑬⑱ are connected internally. GND <Open Collector> ※signal when contact is ON 10 11 12 13 14 15 16 17 18 + − Apply DC12V 2 O.C. COM. N.C. N.O. GND 10 11 12 13 14 15 16 17 18 GND ※ signal when transistor is ON Output・Power Terminal Array O.C. GND <Voltage Input> Input signal detection in ① will start (restart) the Timer. Connect terminal ② to GND to disable Key Operation. Connect terminal ⑤ to GND to stop the Timer, disconnect from GND to restart. Non-contact Output INPUT ※signal when contact is ON ※ Terminals ③④⑨⑫⑬⑱ are connected internally. Output・Power GND GND 6 ● Input Circuit Non-voltage Input(NPN Input) <Reed Input> GND 5 Terminal Array GND 4 GND 3 2 INPUT Input <Open Collector> ② Key Protect ⑤ Disable ② Key Protect GND 1 GND ① Pulse Input <Reed Input> GND Terminal Array ① Pulse Input Input ● Wire Terminal Type: Screw Tightening(use AWG14-22 leadwires) -3- GND ※ signal when transistor is ON
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement