SMX2064/2060, SM2064/2060 1 7- /2 Digit Digital Multimeter Features Operating Systems Flexible, full-featured auto-ranging DMM • Windows 98/NT/2000/XP/2003 7-1/2 digit resolution Recommended Software 20,000 readings/second (SMX2064, SM2064) • VB/VC++/BCB/Delphi 1,400 readings/second (SMX2060, SM2060) • DAQBench DC & AC voltage & current, 2-wire, 4-wire, 6-wire (SMX2064, SM2064) ohms Frequency and time measurements Capacitance & inductance measurements (SMX2064, SM2064) Voltage & current sourcing (SMX2064, SM2064) Precise trigger capabilities 330 V isolation barrier Self-calibrating Plug-and-Play software with graphical user interface Fully programmable with Visual Basic, C++, LabVIEW™ etc. 2-Wire Resistance Introduction Accuracy ± (% of reading + Ω) [1] 1 The SMX2064, SMX2060, SM2064 and SM2060 are 7- /2 digit high-speed Digital Multimeters in PXI and PCI, which maintain high accuracy at high measurement rates. The measurement speed is up to 20,000 readings/second for SMX2064 and SM2064. The SMX206x and SM206x series provide a comprehensive set of DMM capabilities, including 2-wire, 4-wire, and 6-wire guarded resistance measurements; inductance and capacitance; leakage and temperature; frequency and timing; sourcing of voltage and current; and much more. The SMX2064, SMX2060, SM2064 and SM2060 Digital Multimeters are easy to setup and use, have sophisticated analog and digital circuitry to provide repeatable measurements, and are protected to handle any unexpected situation your measurement environment may encounter. With high performance and variable applications, the SMX2064, SMX2060, SM2064 and SM2060 are suitable for automated production testing, laboratory automation, and portable/field testing. DC Functions DC Voltage Accuracy ± (% of reading + Volts) [1] Range Full scale 7-1/2 Digits Resolution Input 24 hours Resistance 23˚C±1˚C 90 Days 23˚C±5˚C 240 mV 240.00000 mV 10 nV >10 GΩ 0.003 + 1 µV 0.004 + 1.5 µV 0.005 + 2 µV 0.0025 + 5 µV One Year 23˚C±5˚C 2.4 V 2.4000000 V 100 nV >10 GΩ 0.002 + 3 µV 24 V 24.000000 V 1 µV 10 MΩ 0.004 + 120 µV 0.005 + 130 µV 0.006 + 150 µV 240 V 240.00000 V 10 µV 10 MΩ 0.003 + 250 µV 0.004 + 300 µV 0.005 + 0.5 mV 330 V 330.00000 V 10 µV 10 MΩ 0.005 + 550 µV 0.01 + 700 µV 0.003 + 5 µV 0.015 + 0.8 mV [1] With Aperture set to ≥ 0.5 sec, and within one hour from Self Calibration (S-Cal) DC Current Accuracy ±(% of reading + Amps) [1] Resolution Max Burden 24 hours Voltage 23˚C±5˚C 90 Days 23˚C±5˚C Current 23˚C±1˚C 90 Days One Year 23˚C±5˚C 23˚C±5˚C 24 Ω[2] 24.000000 Ω 1 µΩ 10 mA 240 Ω 240.00000 Ω 10 µΩ 1 mA 0.0037 + 4.5 mΩ 0.0046 + 5 mΩ 0.007 + 6 mΩ 2.4 kΩ 2.4000000 kΩ 100 µΩ 1 mA 0.0023 + 28 mΩ 0.006 + 33 mΩ 0.0038 + 1.4 mΩ 0.005 + 1.6 mΩ 0.008 + 2 mΩ 0.004 + 32 mΩ 24 kΩ 24.000000 kΩ 1 mΩ 100 µA 0.0025 + 300 mΩ 0.004 + 330 mΩ 0.006 + 350 mΩ 240 kΩ 240.00000 kΩ 10 mΩ 10 µA 0.0055 + 3.2 Ω 0.006 + 4 Ω 0.007 + 5 Ω 2.4 MΩ 2.4000000 MΩ 100 mΩ 1 µA 0.018 + 40 Ω 0.03 + 50 Ω 0.04 + 70 Ω 24 MΩ 24.0000 MΩ 100 Ω 100 nA 0.12 + 400 Ω 0.13 + 500 Ω 0.2 + 600 Ω 1 kΩ 10 nA 0.8 + 20 kΩ 1.0 + 30 kΩ 1.3 + 50 kΩ 240 MΩ[2] 240.000 MΩ [1] With Aperture set to ≥0.5 Sec, and within one hour from Self Calibration (S-Cal). [2] Ranges are only with the SMX2064, SM2064. [3] Test voltages are 2.4 V max with the exception of the 24 Ω and 240 Ω ranges 240 mV. Range [3] Full scale 240 nA[2] 240.0000 nA 0.1 pA 100 µV 0.07 + 40 pA 0.1 + 45 pA 0.17 + 60 pA 2.4 µA[2] 2.400000 nA 1 pA 100 µV 0.05 + 70 pA 0.08 + 90 pA 0.21 + 150 pA 24 µA[2] 24.00000 µA 10 pA Resolution Source 24 hours 7-1/2 Digits Current 23˚C±1˚C 90 Days One Year 23˚C±5˚C 23˚C±5˚C 24 Ω[2] 24.000000 Ω 1 µΩ 10 mA 240 Ω 240.00000 Ω 10 µΩ 1 mA 0.0037 + 3 mΩ 0.0046 + 4 mΩ 0.007 + 5 mΩ 2.4 kΩ 2.4000000 kΩ 100 µΩ 1 mA 0.0023 + 28 mΩ 0.004 + 32 mΩ 0.006 + 33 mΩ 0.0038 + 0.7 mΩ 0.005 + 0.8 mΩ 0.008 + 1 mΩ 24 kΩ 24.000000 kΩ 1 mΩ 100 µA 0.0025 + 300 mΩ 0.004 + 330 mΩ 0.006 + 350 mΩ 240 kΩ 240.00000 kΩ 10 mΩ 10 µA 0.0055 + 3.2 Ω 0.007 + 4 Ω 0.007 + 5 Ω 2.4 MΩ 2.4000000 MΩ 100 mΩ 1 µA 0.018 + 40 Ω 0.03 + 50 Ω 0.04 + 70 Ω 24 MΩ 24.0000 MΩ 100 nA 0.12 + 400 Ω 0.13 + 500 Ω 0.2 + 600 Ω 100 Ω [1] With Aperture set to ≥0.5 Sec, and within one hour from Self Calibration (S-Cal). [2] Ranges are only with the SMX2064, SM2064. [3] Test voltages are 2.4 V max with the exception of the 24 Ω and 240 Ω ranges 240 mV. Diode Characterization Maximum Diode Available DC current Typical Current Typical Voltage Value Voltage Compliance Uncertainty Value Uncertainty 4V 100 nA, 1 µA, 10 µA, 100 µA and 1% 0.02% One Year 23˚C±5˚C 1 mA (SMX2064 and SM2064 10 mA & 12.5 mA) AC Functions AC Voltage (true RMS) One Year Accuracy ± (% of reading + Volts), 23˚C±5˚C 100 µV 0.05 + 400 pA 0.08 + 600 pA 0.13 + 0.8 nA 240 µA[2] 240.000 µA 10 nA 2.5 mV 0.052 + 200 nA 0.07 + 300 nA 0.1 + 400 nA 2.4 mA 2.40000 mA 10 nA 25 mV 0.05 + 300 nA 0.07 + 550 nA 24 mA 24.0000 mA 100 nA 250 mV 0.05 + 350 nA 0.065 + 450 nA 0.08 + 550 nA 240 mV 240.00000 mV 100 nV 3.2 + 430 µV 0.4 + 200 µV 0.15 + 120 µV 0.27 + 230 µV 2.0 + 400 µV 240 m 240.000 mA 1 µA 55 mV 0.05 + 50 µA 0.055 + 60 µA 0.065 + 80 µA 2.4 V 2.4000000 V 1 µV 3.2 + 2.5 mV 0.4 + 1.7 mV 0.065 + 1.2 mV 0.35 + 1.5 mV 2.1 + 2 mV 2.4 A 2.40000 A 10 µA 520 mV 0.3 + 60 µA 0.4 + 70 µA 0.45 + 90 µA 24 V 24.000000 V 10 µV 3.3 + 20 mV 0.073 + 13 mV 0.22 + 25 mV 240 V 240.00000 V 100 µV 3.3 + 200 mV 0.4 + 150 mV 0.06 + 130 mV 0.30 + 200 mV 1.6 + 300 mV 330 V 330.00000 V 100 µV 3.3 + 200 mV 0.45 + 250 mV 0.09 + 230 mV 0.32 + 300 mV 1.6 + 400 mV 0.06 + 400 nA [1] With Aperture set to ≥0.96 sec, and within one hour from zero (Relative control). [2] Available only with the SMX2064 and SM2064. 3-24 7-1/2 Digits Accuracy ± (% of reading + Ω) [1] Specifications subject to change without notice. For the most current and complete specifications, please refer to the user manual. Full scale 6-1/2 Digits Resolution Source 24 hours 4-Wire Resistance Specifications Range Range [3] Full scale www.adlinktech.com Range Full scale Resolution 10Hz - 20Hz 20Hz - 47Hz 47Hz - 10kHz 10kHz - 50kHz 50kHz-100kHz 7 -1/2 Digits 0.4 + 16 mV 1.5 + 40 mV Digital Multimeter AC Current (true RMS) One Year Accuracy ± (% of reading + Amps), 23˚C±10˚C Range Full scale Resolution Max Burden 6-1/2 Digits 10Hz - 20Hz[1] 20Hz - 47Hz[1] 47Hz - 1kHz[1] 1kHz - Voltage (RMS) 2.4 mA 2.400000 mA 1 nA 25 mV 10kHz[1] 2.9 + 4 µA 1.0 + 4 µA 0.12 + 4 µA 0.22 + 4 µA 24 mA 24.00000 mA 10 nA 250 mV 2.8 + 30 µA 1.0 + 30 µA 0.16 + 30 µA 0.4 + 40 µA 240 mA 240.0000 mA 100 nA 55 mV 2.8 + 400 µA 1.0 + 400 µA 0.2 + 220 µA 0.4 + 400 µA 2.4 A 520 mV 2.7 + 5 mA 0.9 + 6 mA 0.35 + 4 mA 0.5 + 5 mA 2.400000 A 1 µA Other measurement functions of SMX2064 and SM2064 6-wire guarded 1 resistance, extended resistance, AC peak-to-peak voltage, AC crest factor, Software Solutions AC median value, leakage current, RTD temperature, thermocouple temperature [1] All AC Current ranges have typical measurement capability to 20 kHz. Time Functions Frequency and Period ACV Mode Input RMS Input Impedance Frequency Range Period Range Resolution Uncertainty Voltage range 24 mV - 250 V 1 MΩ with < 300 pF 2 Hz - 300 kHz 2 Source Functions (SMX2064 and SM2064 only) 0.5 s - 3.33 µs 5 1/2 digits ± 0.002% of reading DC Voltage Source Output range: -10.000 V to +10.000 V DAC resolution: 18 bits (closed loop), 12 bits (open loop) PXI/ CompactPCI Platforms 3 AC Voltage Source Output range: 900 mV to 8 V DAC resolution: 12 bits Frequency range/resolution: 1 Hz to 200 kHz/2 mHz Modular Instrument 4 DC Current Source PXI/ CompactPCI Modules Output range: 1.25 µA to 12.5 mA ACI Mode Input Signal Input Impedance Frequency Period Range Resolution Uncertainty range Range 0.33 mA - 2.5 A 10 Ω(3 mA & 30 mA) 2 Hz - 500 kHz 0.5 s - 2.0 µs 5 1/2 digits Trigger Functions ± 0.01% of reading Trigger input voltage level range: +3 V to +15 V Minimum trigger input current: 1 mA 0.1 Ω (330 mA & 2.5 A) Pulse Width Polarity Frequency Range Resolution Width Range Typical Uncertainty Positive or negative pulse widths 2 Hz to 100 kHz 1 µs 2 µs to 1 s 0.01% of reading ±4 µs Threshold DAC Trigger point: selectable positive or negative transition of set threshold 6 Captures up to 120 post-trigger readings for apertures > 625 µ Sec. GPIB Interface Captures up to 80 post-trigger readings for apertures > 625 µ Sec. Delayed Hardware Trigger Threshold range Threshold DAC Highest allowed Typical one year Up to 65 m Sec with 1 µ Sec resolution Range (DC level) resolution input Vp-p setting uncertainty Up to 1 s with 2 µs resolution 240 mV -1.0 V to +1.0 V 0.5 mV 1.900 V 0.2% + 4 mV 2.4 V -10.0 V to +10.0 V 5.0 mV 19.00 V 0.2% + 40 mV 24 V -100.0 V to +100.0 V 50 mV 190.0 V 0.2% + 0.4 V 240 V -400 V to 400 V 850.0 V 0.2% + 4 V Totalizer Active edge polarity Maximum Count Allowed rate Positive or negative transition 10^9 General Specifications Overload Protection (voltage inputs): 330 VDC, 250 VAC Isolation: 330 VDC, 250 VAC from earth ground Maximum Input (Volt x Hertz): Condition 1 to 30,000 events per second Uses Threshold DAC Capacitance and Inductance Specifications (SMX2064 and SM2064 only) Capacitance Accuracy ±(% of reading + farads) [1] Range Full scale Reading Resolution One Year 23˚C±5˚C Measurement Time Measurement Rate (rps) 8x106 volts x Hz normal mode input 1x106 volts x Hz common mode input Calibration: Calibrations are performed by Signametrics in constants are stored in a text file. Operating Temperature: -10 to 65˚C Storage Temperature: -40 to 85˚C 0.1 pF 1.5 ± 0.25 pF 52.3 ms 19.1 Power requirements: +5 volts, 300 mA maximum 12 nF 11.999 nF 1 pF 1.2 ± 5 pF 118 ms 8.5 Dimensions (not including connectors): 120 nF 119.99 nF 10 pF 1.0 127 ms 7.9 SMX2064/2060: 160 mm x 100 mm 1.2 µF 1.1999 µF 100 pF 1.0 175 ms 5.7 SM2064/2060: 208 mm x 112 mm 11.999 µF 1 nF 1.0 480 ms 2.1 120 µF 119.99 µF 10 nF 1.0 50.3 ms 19.9 1.2 mF 1.1999 mF 100 nF 1.2 151.5 ms 6.6 12 mF 50.000 mF 1 µF 2 170 ms 5.9 [1] Within one hour of zero, using relative control. Accuracy is specified for values higher than 5% of the selected range with the exception of the 1,200 pF range. Inductance Accuracy ± (% of reading + henrys) Range Test Frequency Full Scale 4 1/2 Digits Resolution One Year Accuracy 23˚C±5˚C [1] 24 µH 75k Hz 33.000 µH 1 nH 3.0% + 500 nH 240 µH 50 kHz 330.00 µH 10 nH 2.0% + 3 µH 2.4 mH 4 kHz 3.3000 mH 100 nH 1.5% + 25 µH 24 mH 1.5 kHz 33.000 mH 1 µH 1.5% + 200 µH 240 mH 1 kHz 330.00 mH 10 µH 2.5 + 3 mH 2.4 H 100 Hz 3.3000 H 100 µH 3.0 + 35 mH [1] Accuracy is specified for values greater than 5% of the selected range. 7 PCI/PCI ® Express DAQ Cards 8 PCI/PCI ® Express DIO Cards 9 PC/104-Plus Modules a computer at 23˚C internal temperature rise. All calibration 1,200 pF 1,199.9 pF 12 µF Bus Interface Analog Threshold Trigger Selected VAC 500 mV 5 External Hardware Trigger (at DIN-7 connector) Safety: Designed to IEC 1010-1, Installation Category II Ordering Information SMX2064 7-1/2 digits PXI Digital Multimeter with LCR Meter SMX2060 7-1/2 digits PXI Digital Multimeter SM2064 7-1/2 digits PCI Digital Multimeter with LCR Meter SM2060 7-1/2 digits PCI Digital Multimeter 10 ISA DAS/ DIO Cards 11 System Product 12 Wiring Termination Boards 13 Motion, HSL, Vision, COM & GEME 14 Remote I/O Modules 15 Industrial Computers www.adlinktech.com 3-25
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement