Panasonic 36PEF1U6 Datasheet

Panasonic 36PEF1U6 Datasheet
Split System Submittal Data
System: 36PEF1U6 Indoor: S-36PF1U6 Outdoor: U-36PS1U6
Single Split System - Concealed Duct Heat Pumps
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Approval:
Date:
Construction:
Unit#:
Drawing#:
General Data
Power (V/P/Hz)
Circuit Ampacity (A)
Fuse Size, Max.(A)
230/208/1/60
15-35 Indoor-Outdoor
15-35 Indoor-Outdoor
Compressor
No. Used
R.L. Amps - L.R. (A)
DC Rotary Inverter
1
16.4 - 17.5
Outdoor Unit
Fan type
Dia & Length (in.) - No. used
Type Drive - No. Speeds
No. Poles (RPM)
No. Motors (W)
CFM (High)
F.L. Amps (A)
Propeller
18-7/64-1
DC Motor
8 - 830
1 - 90
1942
17.3
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq.ft.)
Tube Size (in)
Aluminum Fin & Copper Pipe
Slit Plate - Inner Rifled
2 - 14.1
7.26
3/8"
Indoor Unit
Fan type
Dia & Length (in.) - No. used
No. Speeds
No. Poles (RPM, High)
No. Motors (W)
CFM (HI/Med/Lo)
Indoor Sound Rating (Hi) (dB-A)
F.L. Amps (A)
Centrifugal
5-29/32-3
3 & Auto
4 - 940
1 - 100
1060/920/750
38
1.0
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq.ft.)
Tube Size (in)
Drain Connection Size (in.)
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Rifled
3 - 12.7
3.32
3/8"
1-17/64"
Refrigerant
Lbs. - R410a
Control
Connection
Line Length, Max (ft.)
Line Difference, Max (ft.)
Line Size (in. O.D. Discharge)
Line Size (in. O.D. Suction)
R410A
6.17
Electric Expansion Valve
Flare
165
50 (outdoor lower),
100 (outdoor higher)
3/8"
5/8"
Dimensions (HxWxD)
Indoor Unit (Crated) (in.)
Indoor Unit (Uncrated) (in.)
Outdoor Unit (Crated) (in.)
Outdoor Unit (Uncrated) (in.)
14-3/32 x 65-25/32 x 30-13/16
12-7/32 x 58-9/32 x 24-13/16
34-31/32 x 39-31/32 x 16-3/32
30-23/32 x 37 x 13-3/8
Weight (lbs.)
(Indoor) Net
(Indoor) Shipping
(Outdoor) Net
(Outdoor) Shipping
104
115
143
161
(Indoor) Shipping Volume (cu.ft.)
(Outdoor) Shipping Volume (cu.ft.)
16.5
13
Performance Data @ ARI Standard Conditions (230/208V)
Option
Cooling
Total Capacity (BTU/H)
Sensible Capacity (BTU/H)
Latent Capacity (BTU/H)
SEER
Dehumidification (Pints/H)
Amps (A)
Power Inputs (W)
Outdoor Sound Rating (dB-A) High
Refrigerant Line Set
Fresh Air Intake
Airduct Extension
Indoor Frame Extension
Condensate Drain Pump
Non-Removeable Locking
Remo-con Bracket
Heating
Total Capacity (BTU/H)
HSPF
Amps (A)
Max Amps (A)
Power Inputs (W)
Back-up Strip Heather (KW)
Outdoor Sound Rating (dB-A) High
31,200 (9,500 - 31,200)
19,570
11,630
13.9
10.0
18.6/20.6
3,920/3,920
52
37,400 (8,000 - 37,400)
9.6
15.6/17.3
15.6/17.3
3,250/3,250
N/A
52
Features
Controls
Remote Controller
Temperature Control
Timer
Night Setback
Air Louver, Horizontal
Air Louver, Vertical
Power Failure Automatic
Changeover
Heating/Cooling Automatic
Changeover
Self-Diagnosis
Air Filter
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
us.panasonic.com/aircon
Microprocessor
(Wired Remote Included)
(Wireless Remote Optional)
IC Thermostat
72 Hr. On/Off
N/A
N/A
N/A
Built-In
Built-In
Built-In
Field Supplied
Available
N/A
N/A
N/A
Built In (Limited Vertical Lift)
Available
Operating Range
Indoor Air Intake Temp
Outdoor Air Intake Temp
Cooling (Max)
Cooling (Min)
Heating (Max)
Heating (Min)
95F DB/71F WB
67 DB/57F WB
80F DB/67F WB
-DB/-WB
115F DB
0F DB
75F DB/65F WB
5F DB
2-15/16
2-9/16
1-9/16
12-7/32
13-3/16
13-3/16
11
11-7/32
1-3/8
5-1/8
1915_U_I
13-3/16
13-3/16
12-7/32
2-15/16
2-9/16
4-17/32
Refrigerant liquid line (3/8")
Flare connection
Refrigerant gas line (5/8") Flare connection
Upper drain port (O.D. 1-1/4)
Bottom drain port (O.D. 1-1/32)
Suspension lug
Power supply inlet (conduit size 1/2")
Fresh air intake port (ø5-29/32)
Flange for the flexible air outlet duct (ø7-7/8)
Tube cover
Electrical component box
Flange for the air intake duct
(option or field supply)
13-3/16
10
1-9/16
(B) Outdoor Unit: U-26PE1U6, U-26PS1U6
U-36PE1U6, U-36PS1U6
9
(5-29/32)
9
10
58-9/32
3-17/32
Refrigerant liquid line (3/8") Flare connection
Refrigerant gas line (5/8") Flare connection
Upper drain port (O.D. 1-1/4)
Bottom drain port (O.D. 1-1/32)
Suspension lug
Power supply inlet (conduit size 1/2")
Fresh air intake port (ø5-29/32)
Flange for the flexible air outlet duct (ø7-7/8)
Tube cover
Electrical component box
Flange for the air intake duct
(option or field supply)
3-11/32
Dimension : inch
11
Dimension : inch
2-3/4
61-13/32 (Suspension bolt pitch)
Inspection access
(17-23/32 × 17-23/32)
(Field supply)
18-ø1/8
(Hole)
1-7/32
9-1/16
3/4
31/32
2-3/4
13-3/16
58-9/32
61-13/32 (Suspension bolt pitch)
31/32
6-7/8
31/32
8-9/32
12-7/32
1-7/32
10-1/4
15/16
(Air outlet
duct flange)
7-9/32
3-17/32
13-3/16
(B) Outdoor Unit: U-26PE1U6, U-26PS1U6
U-36PE1U6, U-36PS1U6
22-27/32
(Suspension bolt pitch)
31/32
6-5/16
1-3/16
24-13/16
13/32
31/32
11
1-4 Dimensional Data 7-9/32
Outdoor Dimensions
7-15/32
9-1/16 P × 6 = 54-11/32
31/32
(5-29/32)
18-ø1/8
(Hole)
9-1/16
10
9-1/16 P × 6 = 54-11/32
56-25/32 (Air outlet duct flange)
Indoor unit : Low Silhouette Duct Type
36 Type
56-25/32 (Air outlet duct flange)
1-7/32
22-27/32
(Suspension bolt pitch)
4-17/32
1-4 Dimensional data
1-7/32
15/16
1-4 Dimensional Data
13-3/16
12-7/32
2-15/16
2-9/16
4-17/32
13-3/16
58-9/32
61-13/32 (Suspension bolt pitch)
9-1/16
9-1/16 P × 6 = 54-11/32
56-25/32 (Air outlet duct flange)
10-1/4
(Air outlet
duct flange)
3/4
2-3/4
3-11/32
1-9/16
2-3/4
Inspection access
(17-23/32 × 17-23/32)
(Field supply)
18-ø1/8
(Hole)
1-7/32
15/16
3/4
11
10-1/4
(Air outlet
duct flange)
11
31/32
6-5/16
1-3/16
24-13/16
13/32
31/32
(5-29/32)
31/32
Indoor Dimensions
11-7/32
1-3/8
5-1/8
8-9/32
12-7/32
31/32
6-7/8
7-15/32
Inspection access
(17-23/32 × 17-23/32)
(Field supply)
10
1-7/32
1915_U_I
3-17/32
22-27/32
(Suspension bolt pitch)
31/32
Dimension : inch
7-9/32
9
10
11
Refrigerant liquid line (3/8") Flare conn
Refrigerant gas line (5/8") Flare conne
Upper drain port (O.D. 1-1/4)
Bottom drain port (O.D. 1-1/32)
Suspension lug
Power supply inlet (conduit size 1/2")
Fresh air intake port (ø5-29/32)
Flange for the flexible air outlet duct (ø
Tube cover
Electrical component box
Flange for the air intake duct
(option or field supply)
19
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
us.panasonic.com/aircon
Was this manual useful for you? yes no
Thank you for your participation!