Panasonic S22NKU-1 is a multi-system indoor unit wall-mounted air conditioner designed for efficient cooling and dehumidification. It features a DC rotary compressor, a cross-flow fan with five speeds, and an LCD wireless remote controller for precise temperature control. With a cooling capacity of 14,280 BTU/H and a SEER rating of 17, this unit provides powerful and energy-efficient cooling performance. It also includes built-in self-diagnosis and automatic restart functions for added convenience and reliability.
advertisement
Split System Submittal Data
Indoor:
CS-S22NKU-1
Multi System Indoor Units - Wall Mounted
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
General Data
Power (V/P/Hz)
Circuit Ampacity (A)
Fuse Size, Max.(A)
Compressor
No. Used
Output Power (W)
Outdoor Unit
Fan Type
Motor Type
Output Power (W)
Airflow (CFM)
230/208/1/60
25
25
DC Rotary (Inverter)
1
900
Dimensions (HxWxD)
Indoor Unit (Crated) (in.)
Indoor Unit (Uncrated) (in.)
Propeller
DC Motor (8 poles)
38
550-600
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq.ft.)
Indoor Unit
Aluminum (Blue Coated)
Corrugated Fin
2 / 18
N/A
Fan type
No. Speeds
RPM (High)
Cross Flow
5
1460
Motor Output (w)
CFM (QLo/Lo/Me/Hi/SHi)
30
414/464/554/650/670
Indoor Sound Rating (Hi) (dB-A) 47
Coil Type Aluminum Fin & Copper Tube
Fin Type - Pipe Type
Rows - F.P.I
Face Area (sq.ft)
Drain Connection Size Inner Dia.
(mm)
Slit Plate - Inner Rifled
2 / 21
N/A
16.7
Refrigerant
Lbs. - R410a (Outdoor Unit)
R410A
Refrigerant Control Electronic Expansion Valve
Refrigerant Tubing Connections Flare
Line Length, Max (ft.)
Line Difference, Max (ft.)
66
49
Line Size (in. O.D. Discharge)
Line Size (in. O.D. Suction)
Pre-charge, tubing length at shipment
1/4”
5/8”
33’
N/A
11-7/16 x 42-5/32 x 9-9/32
Approval:
Date:
Construction:
Unit#:
Drawing#:
Outdoor Unit (Crated (in.)
Outdoor Unit (Uncrated) (in.)
Weight
Net, Indoor (lbs.)
Net, Outdoor (lbs.)
N/A
31-5/16 x 34-15/32 x 12-5/8
26
117
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity (BTU/H)
SEER
Dehumidification (Pints/H)
Amps (A)
Power Inputs (W)
Outdoor Sound Rating (dB-A)
Sensible 14,280 Latent 6,720
17
6.1
10
2,250
50
Features
Controls
Remote Controller
Temperature Control
Microprocessor
LCD Wireless Type
IC Thermistor
Air Louver, Horizontal
Air Louver, Vertical
Manual
Automatic
Power Failure Automatic Restart Built-In
Self-Diagnosis Built-In
Air Filter Washable, Anti-Mold
Operating Range Indoor Air Intake Temp Outdoor Air Intake Temp
Cooling (Max)
Cooling (Min)
90F DB/74F WB
60F DB/52F WB
115F DB
60F DB
4. Dimensions
Indoor Dimensions
4.1 Indoor Unit
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144 us.panasonic.com/aircon