Pelco Camera Enclosure EHX*E Series User's Manual

Add to my manuals
12 Pages

advertisement

Pelco Camera Enclosure EHX*E Series User's Manual | Manualzz

I N S T A L L A T I O N / O P E R A T I O N

EHX*E Series

Explosionproof

Camera Enclosure

C417M-M (2/06)

Important Safety Instructions

1. Installation and servicing should be done only by qualified service personnel and conform to all local codes.

2. Use only replacement parts Pelco recommends.

3. The installation method and materials should be capable of supporting four times the weight of the enclosure, pan and tilt, camera and lens combination.

4. The camera and lens combination shall not exceed 20 lb (9.06 kg).

5. For marine applications, the installation shall be in accordance with the Electrical Engineering Regulations of the USCG, Subpart J, C.G 259

(46 CFR Parts 110-113).

6. This enclosure has not been evaluated for use on vessels less than 65 feet (19.81 m) long.

7. Thermal shock of window was conducted at 83°C. If the temperature of the window is greater than 73°C in the end product, the thermal shock test must be repeated.

8. Connection facilities must be provided as part of the end product.

9. External or internal grounding connection must be provided for a minimum size conductor of 1.02 mm 2 (18 AWG).

10. Earthing or bonding facility for equipotential conductor should be provided inside the terminal compartment near the other connection facilities.

11. An EEx d IIB stopping box or cable gland must be provided as part of the end product.

12. When included in an end use installation, it must conform to the ATEX requirements.

The product and/or manual may bear the following marks:

This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.

CAUTION:

RISK OF ELECTRIC SHOCK.

DO NOT OPEN.

This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.

Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.

C417M-M (2/06) 3

Description

The EHX*E Series of nonpressurized, explosionproof camera enclosures is designed to meet the rigorous requirements of explosionproof and dust-ignitionproof electrical equipment for installation and use in hazardous locations.

The EHX*E Series is constructed of aluminum and available in 4-, 6-, and 8-inch diameters to accommodate most camera and lens combinations.

They come equipped with a unique camera mounting sled and track assembly that allows fast, easy positioning of the camera assembly and can be securely locked in place.

MODELS

NOTE: Dimensions are inside dimensions.

EHX4E

EHX6E

EHX6E-16

EHX8E

Explosionproof, nonpressurized enclosure, 4-inch diameter x 12-inch length (10.16 cm x 30.48 cm)

Explosionproof, nonpressurized enclosure, 6-inch diameter x 24-inch length (15.24 cm x 60.96 cm)

Same as EHX6E except 16-inch length (40.64 cm)

Explosionproof, nonpressurized enclosure, 8-inch diameter x 24-inch length (20.32 cm x 60.96 cm)

4 C417M-M (2/06)

Installation

The following parts are supplied:

1 Enclosure with attached mounting cradle

1 3/16-inch Allen wrench

1 5 mm Allen wrench

2 1/4-20 x 1/2-inch screws

2 Appleton explosionproof sealable fittings

1 Desiccant bag

1 Sealing instructions for fittings (C903M-A)

1 Service kit

1 Rear O-ring

4 Rear plate mounting screws

1 Tube of Loctite ® 222 low-strength thread locker

A service kit is included in case you need these spare parts in the future. Save this kit.

NOTE: If installing a heater or blower, do it first. Refer to C1495M-B (accessories manual) for instructions on installing heaters and blowers.

1. Attach the cradle to a mount or pan and tilt unit. Follow the instructions supplied with the mount or pan and tilt unit.

2. Remove the enclosure’s rear plate with the supplied 5 mm Allen wrench.

3. Remove the camera sled from the rail in the body by removing the Allen screw in the end of the sled. Use the supplied 3/16-inch Allen wrench.

4. If the camera lens is adjustable, extend the lens to its maximum length.

5. Position the camera over the appropriate mounting holes on the sled and fasten the camera to the sled with the two provided 1/4-20 x

1/2-inch screws. Make sure the lens does not extend beyond the front edge of the sled. This ensures the lens does not contact the enclosure window after installation.

NOTE: You will need to use elevation blocks (EB1 or EB2) to properly elevate cameras with either a low optical center line or a large-diameter lens.

6. Replace the camera sled in the enclosure, but do not reinstall the 1/4-20 Allen screw that holds the sled in place.

7. Install the sealing fittings on the rear of the enclosure. If you only need one fitting for wiring, install the supplied pipe plug in place of one of the fittings.

8. Bring the wiring through the fitting(s) for camera video and power and, if applicable, power for the accessories (heater and/or blower).

Refer to Table A for 24 VAC applications only (accessories and camera).

9. Attach the video cable to the camera. Connect power to the camera and, if applicable, to the accessories.

10. Attach a ground wire to the 10-32 x 3/8-inch screw on the inside of the rear plate.

NOTE: The internal grounding terminal must be used for the equipment grounding connection and the external terminal is for a supplementary bonding connection where local codes or authorities permit or require such connection.

GROUND

SCREW

Figure 1. Grounding Location

11. Push the camera sled all the way into the enclosure and fasten the sled with the 1/4-20 Allen screw.

12. Leave the desiccant bag inside the enclosure to absorb moisture. Replace the rear plate. Apply Loctite to the screws. Loctite 222 lowstrength thread locker prevents corrosion between the stainless steel screws and aluminum enclosure parts. Corrosion causes the parts to seize, resulting in damage to them during disassembly.

C417M-M (2/06) 5

6

13. If required, attach a ground wire to the terminal lug on the rear plate.

NOTE: The internal grounding terminal must be used for the equipment grounding connection and the external terminal is for a supplementary bonding connection where local codes or authorities permit or require such connection.

14. Connect the video and power wiring from the sealing fittings to their sources through fittings and conduit suitable for hazardous locations.

15.

For U.S. and Canada only: Seal the fittings as specified by the manufacturer’s installation instructions in manual C903M-C. Sealant is not supplied or available from Pelco.

Table A. 24 VAC Wiring Distances

10

20

30

40

50

60

70

80

90

100

110

120

130

140

64

(19)

56

(17)

50

(15)

45

(13)

112

(34)

90

(27)

75

(22)

18 AWG

(1.0 mm 2 )

451

(137)

225

(68)

150

(45)

41

(12)

37

(11)

34

(10)

32

(9)

40

(12)

35

(10)

31

(9)

28

(8)

70

(21)

56

(17)

47

(14)

20 AWG

(0.5 mm 2 )

283

(86)

141

(42)

94

(28)

25

(7)

23

(7)

21

(6)

20

(6)

163

(49)

142

(43)

126

(38)

114

(34)

285

(86)

228

(69)

190

(57)

14 AWG

(2.5 mm 2 )

1142

(348)

571

(174)

380

(115)

103

(31)

95

(28)

87

(26)

81

(24)

102

(31)

89

(27)

79

(24)

71

(21)

179

(54)

143

(43)

119

(36)

16 AWG

(1.5 mm 2 )

716

(218)

358

(109)

238

(72)

65

(19)

59

(17)

55

(16)

51

(15)

411

(125)

360

(109)

320

(97)

288

(87)

720

(219)

576

(175)

480

(146)

10 AWG

(6.0 mm 2 )

2880

(877)

1440

(438)

960

(292)

261

(79)

240

(73)

221

(67)

205

(62)

258

(78)

226

(68)

201

(61)

181

(55)

452

(137)

362

(110)

301

(91)

12 AWG

(4.0 mm 2 )

1811

(551)

905

(275)

603

(183)

164

(49)

150

(45)

139

(42)

129

(39)

These are the recommended maximum distances for 24 VAC applications and are calculated with a 10 percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.)

EXAMPLE: An enclosure that requires 80 VA and is installed 35 feet (10 m) from the transformer would require a minimum wire gauge of

20 Awg.

NOTE: Distances are calculated in feet; values in parentheses are meters.

C417M-M (2/06)

Operation

If your enclosure has a heater, the heater turns on at 40°F (4°C) and turns off at 60°F (16°C).

If your enclosure has a blower, the fan operates continuously.

MAINTENANCE

REGULAR MAINTENANCE

WARNING: Do not remove the front cover. If you do, Pelco cannot be held responsible for the loss of explosionproof rating, UL listing, or ability of enclosure to contain an explosion.

Regularly scheduled maintenance will help to prolong the operational life and appearance of the equipment.

1. Periodically look inside the window of the enclosure and check the humidity indicator on the roof. Lavender indicates normal at the desired level of humidity. Pink indicates excessive dampness and blue indicates dryness. For example, if you want to maintain a humidity level of

20%, the 20% dot should be lavender.

2. Clean the window regularly with a mild nonabrasive detergent in water to help maintain picture clarity. For a heavily soiled window, use a glass cleaner.

3. Inspect the sealing fittings frequently for the condition of the sealant.

A service kit containing a rear O-ring and four rear plate mounting screws is included with the enclosure. Use these spare parts if the original parts are damaged or lost during maintenance or repair of the enclosure.

SERVICE MANUAL

If you need to service the enclosure, obtain a service manual in one of the following ways:

Go to Pelco’s web site at www.pelco.com and find service manual C417SM.

Contact Pelco’s Literature Department and request service manual C417SM.

C417M-M (2/06) 7

8

Specifications

Cable Entry

Window

Window Viewing Area

EHX4E

EHX6E

EHX6E-16

EHX8E

Window Thickness

EHX4E

EHX6E, EHX6E-16, EHX8E

Maximum Camera and Lens Size

EHX4E

EHX6E

EHX6E-16

EHX8E

EHX4E (only)

EHX4E

EHX6E

EHX6E-16

EHX8E

Construction

Finish

Dimensions

2 explosionproof sealable fittings

Ground and polished, fully tempered plate glass

3.19 in. (8.10 cm) diameter

3.00 in. (7.62 cm) diameter

3.00 in. (7.62 cm) diameter

4.25 in. (10.80 cm) diameter

0.475 in. (1.21 cm) thick

0.500 in. (1.27 cm) thick

(Without Blower or Heater)

2.75 (H) x 3.375 (W) x 12.00 (L) inches

(6.99 x 8.57 x 30.48 cm)

12.0 (L) x 3.0 (diameter) inches (30.48 x 7.62 cm)

3.75 (H) x 4.375 (W) x 24.00 (L)

(9.53 x 11.11 x 60.96 cm)

24.0 (L) x 5.0 (diameter) inches (60.96 x 12.70 cm)

3.750 (H) x 4.375 (W) x 16.00 (L) inches

(9.53 x 11.11 x 40.64 cm)

16.0 (L) x 5.0 (diameter) inches (40.64 x 12.70 cm)

5.75 (H) x 5.125 (W) x 24.00 (L) inches

(14.60 x 13.02 x 60.96 cm)

24.0 (L) x 7.3 (diameter) inches (60.96 x 18.54 cm)

(With Heater Only)

2.75 (H) x 3.375 (W) x 10.375 (L)

(6.99 x 8.57 x 26.35 cm)

10.38 (L) x 3.00 (diameter) inches (26.36 x 7.62 cm)

(With Blower Only or Blower and Heater)

2.75 (H) x 3.375 (W) x 9.00 (L) inches

(6.99 x 8.57 x 22.86 cm)

9.0 (L) x 3.0 (diameter) inches (22.86 x 7.62 cm)

3.75 (H) x 4.375 (W) x 22.25 (L) inches

(9.53 x 11.11 x 56.52 cm)

22.25 (L) x 5.00 (diameter) inches (56.52 x 12.70 cm)

3.75 (H) x 4.375 (W) x 14.25 (L)

(9.53 x 11.11 x 36.20 cm)

14.25 (L) x 5.00 (diameter) inches (36.20 x 12.70 cm)

5.75 (H) x 5.125 (W) x 22.25 (L)

(14.60 x 13.02 x 56.52 cm)

22.25 (L) x 7.30 (diameter) inches (56.52 x 18.54 cm)

Aluminum 6061 T6

Gray polyester powder coat

See Figure 2

C417M-M (2/06)

Certifications and Ratings Classified by Underwriters Laboratories Inc. as to explosion and fire hazard only

Type 4X enclosure for use in hazardous locations

Class I, Groups C and D – Class II, Groups E, F, and G

Class I, Zone 1, AEx d IIB, Ex d IIB

03 ATEX 0318166U

0035 II 2 G EEx d IIB

II 2 D, IP 66

Suitable for marine outside (saltwater) use, for vessels over 65 feet in length

Weight

EHX4E

EHX6E

EHX6E-16

EHX8E

15 lb (6.79 kg)

31 lb (14.04 kg)

27 lb (12.23 kg)

45 lb (20.41 kg)

(Design and product specifications subject to change without notice.)

E A B

C

F

G

5.00

(12.70)

H

7.00

(17.78)

6.25

(15.87)

9.00

(22.86)

EHX6E/8E

MOUNTING CRADLE

2.00

(5.08)

6.00

(15.24)

EHX4E

3.00

(7.62)

MOUNTING CRADLE

1/4-20

PEMNUT 2X

DIM

A

B

C

F

G

D

E

H

EHX4E

Ø7.00

Ø4.50

EHX6E-16

(17.78) Ø8.00

(11.43) Ø6.63

EHX6E

(20.32) Ø8.00

(16.83) Ø6.63

(20.32) Ø10.13 (25.72)

(16.83)

EH8E

Ø8.63 (21.92)

6.75 (17.15) 7.85 (19.94) 7.85 (19.94) 9.65 (24.51)

14.25 (36.20) 18.70 (47.50) 26.70 (67.82) 26.67 (67.74)

18.25 (46.36) 22.70 (57.66) 30.70 (77.98) 30.67 (77.90)

N/A 8.57 (21.77) 8.57 (21.77) 9.12 (23.16)

NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.

Figure 2. EHX*E Series Dimension Drawing

C417M-M (2/06) 9

PRODUCT WARRANTY AND RETURN INFORMATION

WARRANTY

Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.

Exceptions to this warranty are as noted below:

• Five years on FT/FR8000 Series fiber optic products.

• Three years on Genex ® Series products (multiplexers, server, and keyboard).

• Three years on Camclosure ® and fixed camera models, except the CC3701H-2,

CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a five-year warranty.

• Three years on PMCL 200/300/400 Series LCD monitors.

• Two years on standard motorized or fixed focal length lenses.

• Two years on Legacy ® , CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.

• Two years on Spectra ® , Esprit ® , ExSite ™ , and PS20 scanners, including when used in continuous motion applications.

• Two years on Esprit ® and WW5700 Series window wiper (excluding wiper blades).

• Two years (except lamp and color wheel) on Digital Light Processing (DLP ® ) displays.

The lamp and color wheel will be covered for a period of 90 days. The air filter is not covered under warranty.

• Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, Endura ™ Series distributed network-based video products, and TW3000 Series twisted pair transmission products.

• One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.

• Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).

Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,

California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.

Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.

The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.

If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or

(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:

1. Model and serial number

2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number

3. Details of the defect or problem

If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.

Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.

RETURNS

In order to expedite parts returned to the factory for repair or credit, please call the factory at

(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).

All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.

Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.

If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:

Service Department

Pelco

3500 Pelco Way

Clovis, CA 93612-5699

If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following:

If the goods are to be sent by a COURIER SERVICE, send the goods to:

Pelco

3500 Pelco Way

Clovis, CA 93612-5699 USA

If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:

Pelco c/o Expeditors

473 Eccles Avenue

South San Francisco, CA 94080 USA

Phone: 650-737-1700

Fax: 650-737-0933

This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.

REVISION HISTORY

Manual #

C417M-I

C417M-J

C417M-K

C417M-L

C417M-M

Date

7/97

9/97

11/97

4/98

8/98

7/99

6/03

2/06

Comments

Rev. I. Updated manual to new format. Revised installation instructions and added assembly drawings to show all new enclosures, which were redesigned by Engineering to meet additional and more stringent standards for global certification. Model numbers changed.

Added service kit per ECO# 97-401.

Added instructions to apply Loctite® to screws per ECR# 1182. Removed column for 22-gauge wire from Table B.

Added Important Note in Section 3.0. In Figure 12 changed dimension D for EHX4E per ECO #97-335.

Rev. J. Moved all material relating to heaters and blowers to new accessories manual C1495M, including the enclosure accessory wiring distances table. Moved exploded assembly diagrams, wiring diagrams, and parts lists relating to the enclosures to a new service manual, C417SM. Renumbered sections, figures, and tables.

Added maximum camera and lens sizes. Modified Figure 1, and window and weight specifications. Updated to new format.

Removed references to model EHX10E, updated Certifications and Safeguards and Warnings sections, and added Figure 1.

Revised camera specifications for EHX4E. Added WEEE statement.

Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.

Endura and ExSite are trademarks of Pelco.

Loctite is a registered trademark of the Loctite Corporation.

DLP is a registered trademark of Texas Instruments, Inc.

© Copyright 2006, Pelco. All rights reserved.

Worldwide Headquarters

3500 Pelco Way

Clovis, California 93612 USA

USA & Canada

Tel: 800/289-9100

Fax: 800/289-9150

International

Tel: 1-559/292-1981

Fax: 1-559/348-1120 www.pelco.com

ISO9001

United States

|

Canada

|

United Kingdom

|

The Netherlands

|

Singapore

|

Spain

|

Scandinavia

|

France

|

Middle East

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement