Pentair and P8 Installation manual


Add to my manuals
32 Pages

advertisement

Pentair and P8 Installation manual | Manualzz

Installation Data

Installation Man u al

PDA - Pool Digital

Assistant

Pool/Spa Combination Systems and

Pool Only/Spa Only Systems

(Models PS4, PS6, PS8, P4, and P8)

Firmware Revision 2.6

WARNING

FOR YOUR SAFETY - This product must be installed and serviced by a pro fes sion al pool/spa service technician. The procedures in this manual must be followed ex act ly. Failure to follow warning notices and instructions may result in property damage, serious injury, or death.

ATTENTION

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment to an electrical source on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

Modifi cations made to this equipment, which are not authorized by the manufacturer, may void the user’s authority to operate this equipment.

Page 3

Table of Contents

Section 1. Important Safety Instructions .............. 4

Section 2. System Overview ................................... 6

2.1 Package Contents .................................... 6

2.2 System Component Specifi cations and Dimensions ....................................... 7

2.3 Basic Plumbing ....................................... 8

Section 3. Installation ............................................. 10

3.1 Power Center Mounting .......................... 10

3.2 High Voltage Wiring ............................... 10

3.3 Low Voltage Wiring ................................ 14

3.4 Heater Connection .................................. 15

3.5 Temperature Sensors ............................... 17

3.6 Jandy Valve Actuators ............................. 17

3.7 PDA Transceiver J-box Installation ........ 17

Section 4. System Startup ....................................... 19

4.1 Handheld Remote Programming ............. 19

4.2 Restarting the System

(Clear Memory) Menu ............................ 22

4.3 PDA System Defaults and

General Modes ........................................ 22

4.4 PDA Handheld Remote Menu

Flow Chart .............................................. 24

Section 5. Troubleshooting ..................................... 25

5.1 PDA Quick Troubleshooting Guide ........ 25

Section 6. Power Center Wiring Diagram ............ 27

Section 7. Power Center PCB DIP Switch

Settings ................................................... 28

7.1 DIP Switch Functions ............................. 28

7.2 DIP Switch Settings for Pool and

Spa Combination ..................................... 29

7.3 DIP Switch Settings for Pool or

Spa Only.................................................. 30

Section 8. General, Water Feature and

Light Aux Labels ................................... 31

EQUIPMENT INFORMATION RECORD

DATE OF INSTALLATION

INSTALLER INFORMATION

INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)

PUMP MODEL

FILTER MODEL

HORSEPOWER

SERIAL NUMBER

PDA MODEL

NOTES:

SERIAL NUMBER

Page 4

Section 1. Important Safety Instructions

READ AND FOLLOW ALL INSTRUCTIONS

LIRE LA NOTICE TECHNIQUE.

All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:

DANGER

To reduce the risk of injury, do not remove the suction fittings of your spa or hot tub. Never operate a spa or hot tub if the suction fittings are broken or missing. Never replace a suction fitting with one rated less than the flow rate marked on the equipment assembly .

WARNING

Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6° F. The symptoms of hyperthermia include dizziness, fainting, drowsiness, lethargy, and an increase in the internal temperature of the body. The effects of hyperthermia include: 1) unawareness of impending danger; 2) failure to perceive heat; 3) failure to recognize the need to exit spa; 4) physical inability to exit spa; 5) fetal damage in pregnant women; 6) unconsciousness resulting in a danger of drowning.

WARNING

To Reduce the Risk of Injury a) The water in a spa should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and

104°F (40°C) are considered safe for a healthy adult. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes.

b) Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C).

c) Before entering a spa or hot tub, the user should measure the water temperature with an accurate thermometer since the tolerance of water temperature-regulating devices varies.

d) The use of alcohol, drugs, or medication before or during spa or hot tub use may lead to unconsciousness with the possibility of drowning.

e) Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a spa.

f) Persons using medication should consult a physician before using a spa or hot tub since some medication may induce drowsines while other medication may affect heart rate, blood pressure, and circulation.

WARNING

Risk of electric shock - Install the power center at least five (5) feet (152.4cm) from the inside wall of the pool and/or hot tub using non-metallic plumbing. Canadian installations must be at least three (3) meters from the water.

Children should not use spas or hot tubs without adult supervision.

Do not use spas or hot tubs unless all suction guards are installed to prevent body and hair entrapment.

People using medications and/or having an adverse medical history should consult a physician before using a spa or hot tub.

AVERTISSEMENT

Danger d'electrocution - Les installations Canadiennes doivent se trouver à au moins trois (3) mètres de l’eau.

Ne pas laisser les enfants utiliser une cuve de relaxation sans surveillance.

Pour éviter que les cheveux ou une partie du corps puissent être aspirés, ne pas utiliser une cuve de relaxation si les grilles de prise d'aspiration ne sont pas toutes en place.

Les personnes qui prennent des médicaments ou ont des problèmes de santé devraient consulter un médecin avant d’utiliser une cuve de relaxation.

Page 5

WARNING

People with infectious diseases should not use a spa or hot tub.

To avoid injury, exercise care when entering or exiting the spa or hot tub.

Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning.

Pregnant or possibly pregnant women should consult a physician before using a spa or hot tub.

Water temperature in excess of 100°F/38°C may be injurious to your health.

Before entering a spa or hot tub measure the water temperature with an accurate thermometer.

Do not use a spa or hot tub immediately following strenuous exercise.

Prolonged immersion in a spa or hot tub may be injurious to your health.

Do not permit any electric appliance (such as a light, telephone, radio, or television) within 5 feet (1.5 m) of a spa or hot tub.

The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas.

Water temperature in excess of 100°F/38°C may be hazardous to your health.

AVERTISSEMENT

Les personnes atteintes de maladies infectieuses ne devraient pas utiliser une cuve de relaxation.

Pour éviter des blessures, user de prudence en entrant dans une cuve de relaxation et en sortant.

Pour éviter l’évanouissement et la noyade éventuelle, ne prendre ni drougue ni alcool avant d’utiliser une cuve de relaxation ni quand on s’y trouve.

Les femmes enceintes, que leur grossesse soit confi rmée ou non, devraient consulter un médecin avant d’utiliser une cuve de relaxation.

Il peut être dangereux pour la santé de se plonger dans de l’eau à plus de 38°C/100°F.

Avant d’utiliser une cuve de relaxation mesurer la témperature de l’eau à l’aide d’un thermomètre précis.

Ne pas utiliser une cuve de relaxation immédiatement après un exercice fatigant.

L’utilisation prolongée d’une cuve de relaxation peut être dangereuse pur la santé.

Ne pas placer d'appareil électrique (luminaire, téléphone, radio, téléviseur, etc) à moins de 1.5m de cette cuve de relaxation.

La consommation d’alcool ou de drogue augmente considérablement les risques d’hyperthermie mortelle dans une cuve de relaxation.

Il peut etrê dangereux pour la santé de se plonger dans de l’eau à plus de 38°C/100°F.

WARNING

To avoid injury ensure that you use this control system to control only packaged pool/spa heaters which have builtin operating and high limit controls to limit water temperature for pool/spa applications. This device should not be relied upon as a safety limit control.

CAUTION

A terminal bar marked "GROUND" is provided within the power center. To reduce the risk of electrical shock, connect this terminal bar to the grounding terminal of your electric service or supply panel with a continuous copper conductor having green insulation and one that is equivalent in size to the circuit conductors supplying this equipment, but no smaller than no. 12 AWG (3.3mm). In addition, a second wire connector should be bonded with a no. 8 AWG (4.115mm) copper wire to any metal ladders, water pipes, or other metal within five (5) feet (1.52m) of the tub.

CAUTION

A ground-fault circuit-interrupter must be provided if this device is used to control underwater lighting fixtures. The conductors on the load side of the ground-fault circuit-interrupter shall not occupy conduit, boxes, or enclosures containing other conductors unless the additional conductors are also protected by a ground-fault circuitinterrupter. Refer to local codes for complete details.

Attention installer: Install to provide drainage of compartment for electrical components.

SAVE THESE INSTRUCTIONS

Page 6

Section 2. System Overview

All Jandy AquaLink RS Systems come complete with the appropriate number of 3HP relays needed.

Pool Digital Assistant (PDA) System Sub-Assembly

PDA Handheld Remote Outdoor Transceiver J-box Power Center PCB

Two (2) Temp Sensors,

Additional Relays (Model Dependent)

Two (2) JVAs

(With Pool/Spa Combination Only)

Power Centers (Sold Separately)

Standard Power Center

(with mounting brackets)

Sub-Panel Power Center

(with mounting brackets and circuit breaker mounting plate)

PureLink Standard Power Center

(with mounting brackets)

PureLink Sub-Panel Power Center

(with mounting brackets and circuit breaker mounting plate)

2.2 System Component Specifi cations and Dimensions

Table 1

Specifications (USA and Canada)

Power Supply

Contact Rating (Relays)

120 VAC; 60 Hz; 3 A

High voltage - 25 A; 3HP @ 240 VAC

1½ HP @120 VAC

Service Switch

Dimensions

Low Voltage - Class Two, 1 A @ 24 VAC

All Circuits (located at Power Center in Service Mode)

3½"

7 /

8

"

4"

7"

1 1 /

16

"

Page 7

6¾"

6"

1"

Front View Side View (at Angle)

J-Box Transceiver

5"

Front View Side View

PDA Handheld Remote

5"

14½"

14½"

Standard Power Cen ter

13¾"

20"

Note Breakers for Sub-Panel Power Center only.

Sub-Panel Power Cen ter

Page 8

2.3.1 Plumbing for Pool and Spa Combination

The following plumbing diagrams illustrate simplified versions of standard plumbing setups for a pool and spa that share the same filter pump, filter, and heater. The intake and return Jandy Valve

Actuators (JVAs) turn si mul ta neous ly so when the

Spa mode is selected on the AquaLink RS PDA, water circulation switches between pool and spa

(consult the Jandy Valve Actuator Installation and

Operation Manual to ensure that the JVAs are synchronized and rotate properly). Please consult the Jandy Valve Plumb ing Manual for further examples of pool/spa plumbing.

From Solar

Please note that if you have a pool only or a spa only, the diagram does not apply.

NOTE When the filter system is shared (a Pool/Spa

Combo), the spa water must be able to overflow into the pool.

To Solar

Heat Pump

Heater

Pool Return

Check

Valve

Filter

Pump

Spa

Make-up

Filter

Check

Valve

Spa Return

Pool Drain

Skimmers

Spa Drain

Skimmers

2.3.2 Booster Pump Pool Cleaner Plumbing

Heater

Booster

Pump

Pool Return

Filter

Pump

Spa Make-up

Check

Valve

Filter

Spa Return

Pool Intake Spa Intake

Page 9

2.3.3 Non-Booster Pump Pool Cleaner Plumbing

Heater

Pool Return

Filter

Pump

Filter

Spa Make-up

Check

Valve

Spa Return

Cleaner

Line

Energy

Filter

Pool Intake Spa Intake

Page 10

Section 3. Installation

3.1 Power Center Mounting

1. The Power Center should be located at or near the equipment pad. Locate the Power

Center at least fi ve (5) feet or more away from pool/spa and fi ve (5) feet off the ground. All na tion al, state, and local codes are applicable.

NOTE For Canadian installations, the Power Center must be at least three (3) meters (9.8 feet) away from the pool/spa and 1.5 meters (5 feet) above the ground.

2. Use the mounting brackets and instructions provided with the Standard Power Center and/or Sub-Panel Power Center.

3. Sub-Panel Power Centers have special code requirements. Be sure to follow all applicable local and state codes to insure safe installation.

NOTE The Power Center is not to be considered as suitable for use as Service Equipment.

Therefore, it is required to have the appropriate means of disconnection, circuit isolation, and/or branch circuit protection installed upstream of the Power Center.

3.2 High Voltage Wiring

Filter Pump Relay Aux. 3 Relay

Neutral

Transformer

Black

White

Wire nut to

120 VAC power

Earth Ground

Breaker Panel

Figure 1. Standard Power Center

To 120 VAC

Breaker

Transformer

Black

White

WARNING

Potentially high voltages in the AquaLink RS

Power Center can create dangerous electrical hazards, possibly causing death, serious injury or property damage. Turn off power at the main circuit feeding the AquaLink RS Power Center to disconnect the Power Center from the system.

Depending on the amount of equipment being controlled, run ½" or larger conduit from the power supply panel to the bottom of the Power

Center. If you are using the Sub-Panel Power

Center, wire power to the appropriate breakers.

Pull in ap pro pri ate wire for equipment. Each piece of equipment requires its own high voltage relay.

Connect 120 volts to the Power Center terminals.

Connect equipment ground(s). See Figures 1 and 2.

White

White

Earth Ground

Black

Black

Ground

From Main

Power

Figure 2. Sub-Panel Power Center

3.2.2 3HP (Standard) Relays

For each piece of 240 volt equipment to be controlled, connect line power to the two (2) line

terminals and connect equipment power to the two

(2) load terminals on the same relay.

For each piece of 120 volt equipment, connect

power to a line terminal and connect equipment to

a load terminal on the same relay.

NOTE The following are the contact ratings for 3HP

(Standard) Relay. DO NOT exceed any ratings.

3 HP @ 240 VAC; 1½ HP @ 120 VAC; 25

Amps; 1500 Watts.

Page 11

3.2.3 Bonding the Power Center

Install a bonding lug to the Power Center enclosure. Connect the bond lug, using a #8 solid copper core wire, to an approved earth ground (an approved ground stake, grid, or conducting metal water pipe buried to a sufficient depth). See

Figure 3.

Filter Pump

(240 VAC)

Blower

(120 VAC)

Figure 3. Standard Power Center - Bonding

Bonding Lug

Breaker

Panel

Earth

Ground

Page 12

3.2.4 Underwater Lighting GFCI Wiring

CAUTION

A Ground Fault Circuit Interrupter (GFCI) must be provided in high voltage pool/spa lights. Do not use a GFCI circuit breaker.

The conductors on the load side of the GFCI circuit shall not occupy conduit, boxes, or enclosures containing other conductors unless the other conductors are also on the load side of a GFCI. Refer to local codes for complete details.

1. For a Standard Power Center, install an appropriately rated GFCI receptacle next to the breaker panel. For a Sub-Panel Power

Center install an appropriately rated GFCI receptacle in the Power Center (use the knockout provided on the right side of the

Sub-Panel Power Center). See Figure 4.

2. Connect neutral and hot wire (from circuit breaker) to the LINE side of the GFCI.

3. Connect neutral (white wire) and the hot

(black wire) from the light to the LOAD side of the GFCI.

4. Connect ground from the light to the grounding bar inside the Power Center.

3.2.5 Jandy Pool and Spa Lights Wiring

The Jandy Pool and Spa Lights can be wired into the Jandy AquaLink RS control system to ensure simplified operation of the lights, as well as a means to synchronize the color change function.

Connect the lights to one of the auxiliary relays in the Power Center.

NOTE It is recommended to connect one light per relay so each light can be controlled separately.

However, up to four lights can be connected on a single relay. If there are more than four lights installed on one AquaLink RS system, ensure there is more than one auxiliary relay available in the Power Center.

Refer to Figures 5 and 6 to connect the Jandy Pool and Spa Lights to the Power Center.

NOTE The Jandy Pool and Spa Lights are available in 120-volt and 12-volt versions. If installing a

12-volt light, a 120-volt/12-volt step-down (AC) transformer, listed/certified for the application must be used. For more information about 12volt installations, refer to the Jandy Digital,Color

Changing,Underwater Pool and Spa Lights

Installation and Operation Manual.

OPTIONAL

Standard Power Center

GFCI

Outlet

OPTIONAL

GFCI Outlet

(Optional)

Sub-Panel Power Center

Figure 4. GFCI Installation for Underwater

Lighting

120 VAC

Power Supply

Neutral GFCI

Ground

Ground

Figure 5. 120-Volt Jandy Pool and Spa Light Wiring Diagram

Black

White

Green

Junction

Box

120V

Jandy

Light

120 VAC

Power Supply

Neutral

Ground

Ground

GFCI

Black

White

Green

120V/12V

Transformer

Black

White

Green

Figure 6. 12-Volt Jandy Pool and Spa Light Wiring Diagram

Junction

Box

12V

Jandy

Light

Page 13

Page 14

3.3 Low Voltage Wiring

Plug the 24 VAC power plug from the transformer into its 3-pin terminal on the back of the Power

Center PCB (see Figure 7). Mount the Bezel to the

Power Center using the screws provided. Ensure that battery wires are kept from being pinched or damaged.

CAUTION

DO NOT INSTALL BATTERY until ready to power up system.

24 VAC Power Plug

Connection

Low Voltage

Raceway

Conduit Knockout for Low Voltage

PDA J-box Wire

Heyco Fittings for

Low Voltage JVA and Sensor Wires Figure 7. Power Center PCB (back view)

3.3.2 PDA J-Box Cable Connection to Power

Center PCB

Make provision for the cable to be run between the

PDA J-box and the Power Center. Never run high

voltage and low voltage in the same con duit. Pull cable through the knockout with the Heyco fitting and into the low voltage compartment. Strip back jacket 6". Strip each wire a ¼" and connect to the red, 4-pin connector on the Power Center PCB. A mul ti plex kit may be required if there are more than two cables running to a red, 4-pin connector (see

Figure 8).

NOTE For detailed tranceiver installation, see

Section 3.7.1.

High Voltage

Knock outs for

Conduit

(DO NOT run any Low

Voltage wires through these knockouts)

Figure 8. PDA J-Box Cable Connection to Power

Center PCB

The heater connection section applies to all heaters or heat pumps with thermostatic circuitry of 24 VAC or less (see pages 15 thru 17 for brand specific installation).

NOTE If you are connecting a heater with thermostatic circuitry of 120 VAC or greater, do not connect to the green, 10-pin Terminal Bar. Instead, connect the heater to a high voltage relay in the Power Center and plug the spare relay into the Electric Heater relay socket located on the upper right hand corner of the Power Center

PCB.

3.4.1 Jandy Brand Heater Connections

1. Connect two #14 gauge wires, designed for use in hot en vi ron ments, to the #1 and #2 terminals on the green, 10-pin Terminal Bar.

2. Connect the other ends of the #14 gauge wires from Step 1 to the Fireman's Switch terminal bar in place of the factory installed wire loop.

3. Do not disconnect high limit or pressure switches.

4. Turn the heater thermostat(s) to maximum setting.

5. Turn the heater switch to the ON position.

For dual thermostat heaters turn switch to

Spa position.

Green 10-pin

Ter mi nal Bar

#14

Gauge

Wire

Page 15

3.4.2 Guidelines for Sophisticated Diagnostic

Communication to LX Heaters

1. Remove the LX GUI from the heater.

2. Confi rm the LX and AquaLink RS software revisions are compatible (see table).

3. Run a 4-conductor cable from the LX GUI red, 4-pin connector to the RS power Center red, 4-pin connector (see Figure 10).

LX Software Revision AquaLink RS Software

C10, C11 or later

Revision

PDA 1.0 or later

NOTE If connecting more than two (2) items to the RS

Power Center red, 4-pin con nec tor, a Multiplex

PCB is required.

PDA

J-box

4-Conductor

Wire

4 3 2 1

OPTIONAL

RS Power

Center

Power Center PCB/Bezel

Factory

Installed

Wire Loop

Heater

Ther mo stat To

Max.

Heater Toggle

Switch To On

Heater

Wiring

Terminal 1

Terminal 2

Heater Fireman's Switch

Con nec tion

Figure 9. Lite2 Heater Connection

RED

BLK

YEL

GRN

LX GUI

Figure 10. LX Heater Connection to Power Center

3.4.3 Other Brands Heater Connections

To set up heater connections on heaters manufactured by Hayward, Pentair, and Raypak, please refer to the Installation Manual provided with these heaters.

Page 16

3.4.4 Guidelines for a Gas Heater and a Jandy

AE Series Heat Pump/Chiller Installation

NOTE The following steps provide the procedure for installing a Jandy AE Series Heat Pump.

Ohms, in the solar sensor terminals #3 and

#4 of the green, 10-pin terminal bar of the

AquaLink RS Power Center (see

Figure 16).

2. To run the wires from the Heat Pump, remove the 5 screws that attach the service/ wiring cover panel to the heat pump (see

Figure 16).

NOTE One end of the wiring reserved to run into the conduit connection labeled “Low Voltage

Connection”, located on the lower right hand side of the heat pump (see Figure 16).

3. Run the wires from the Heat Pump control panel through the wiring conduit located on the outer right hand side of the Heat Pump.

4. Connect the Heat Pump to a standard relay, then connect the relay to the solar pump output on the PCB. Set the time to

11:59 PM; at 12:00 AM, the AquaLink

RS will auto-relabel Solar as Heat Pump.

Otherwise, the AquaLink RS will autorelabel Solar as Heat Pump within 24 hours.

5. The Solar Button will activate the heat pump/chiller and the Pool and/or Spa

Heater Buttons will activate the gas heater.

In this manner the pool or spa can be heated or chilled by the heat pump, the gas heater or both.

NOTE To program the Heat Pump control panel, refer to the Jandy AE Series Heat Pump Manual.

PDA

Transceiver

J-box

2.2K Ohms Resistor in Solar Sensor

Terminals for Heat

Pump/Chiller

Gas Heater Connections

Terminals 1 and 2

To Pressure

Switch

4 3 2 1 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1

Fireman's

Switch

From Fusible

Link

Battery

(9Volt)

Heat Pump/Chiller #1

Standard

High

Voltage

Relay

Gas Heater

Heat Pump/Chiller #2

To Heat Pump #2

Port for Low

Voltage Wires

To Heat Pump #1

Service/Wiring

Cover Panel

Figure 16. Heater and Heat Pump/Chiller Wiring

Low Voltage

Wiring to Low

Voltage Port on Heat Pump

Service/Wiring

Cover Panel

Port for Low

Voltage Wires

Page 17

1. Drill 3/8" hole in pipe between fi lter pump and fi lter and install the Water

Temperature Sensor per instructions

(make certain the o-ring is in place).

Power Center can, not in direct sunlight and away from motors and other heat sources.

(optional) adjacent to solar panels.

4. Run the wire to the Power Center, through the low voltage raceway. Cut off excess wire. Strip the wire jacket back 6", then strip each wire ¼". Connect sensor wires to the green, 10-pin terminal bar (see

Figure 17).

Water

Temperature

Sensor

Freeze/Air

Temperature

Sensor

Solar

Temperature

Sensor

10 9 8 7 6 5 4 3 2 1

Green 10-Pin Terminal Bar

Figure 17. Temperature Sensor Wiring for a Pool/

Spa Combination

NOTE Mount the JVAs according to the Jandy Valve

Actuator Installation and Operation Manual.

JVA cable is type SJW-A marked water resistant class 3 cable and does not require conduit.

Knockouts and Heyco fittings are provided in the

Low Voltage Raceway.

1. Route the JVA wire to the Power Center.

2. Run the wire through the low voltage raceway and plug the JVA connectors into their proper sockets (see Section 6. Power

Center Wiring Diagram). Verify that the

JVA on the suction plumbing is connected to the Intake JVA Socket, and the discharge plumbing is connected to the Return JVA

Socket.

NOTE Do not coil the JVA wires inside Power Center.

To shorten the wire, remove the JVA cover and disconnect the wire. Shorten, strip, and reconnect.

3. For alternate plumbing confi gurations the

JVA cam settings can be adjusted as needed.

See the Jandy Valve Actuator Installation and Operation Manual, Cam Setting Chart for proper settings.

3.7 PDA Transceiver J-box Installation

Installation Considerations. The transceivers will transmit through walls and around corners. Steel framing, aluminum siding, wrought iron, cyclone fences, lead ed glass, and other 900 MHz frequency items may inhibit/prevent com mu ni ca tion between the AquaL ink RS PDA Handheld Remote and the

Power Center. The trans ceiv ers do not require

line of sight to communicate. To optimize communication, install trans ceiv ers in a location that minimizes interference.

3.7.1 Outdoor Transceiver J-box Installation

1. Turn off all power to the Power Center.

2. Mount the Outdoor Transceiver J-box at least 6' above the ground and at least 8' from an air blower (see Figure 18).

NOTE To improve performance of the transceiver, mount the J-box more than 6' above the ground.

3. Open the door to the Power Center and remove the dead panel.

4. Feed the four conductor wire into the Power

Center through the low volt age raceway.

5. Cut off the excess wire. Strip the jacket back 6" and strip the individual wires approximately ¼". Connect the four conductor wire to the red terminal bar on the Power Center PCB.

6. Install the dead panel to the Power Center and restore all power.

Page 18

PDA

Trans ceiv er

J-box

Ground

Level

6'

Minimum 8'

Low Voltage Raceway

Power

Center

3. Install two (2) AA batteries. Ensure that the polarity is correct.

4. Re-install the cover for the battery chamber and secure with the two (2) screws removed in Step 2.

3.7.3 Changing the Frequency Channel

If your AquaLink RS PDA system is turning items on or off at undesignated times, another AquaLink

RS PDA system may be in close proximity using the same or similar frequency channel. To prevent unwanted operation the channel for your AquaLink

RS PDA system can be changed. The Power Center

Trans ceiv er and the PDA Transceiver J-box must

be set to the same RF channel.

1. At the Transceiver J-box, remove the cover to expose the PCB (see Figure 20).

Red 4-Pin

Terminal Bar

Air

Blower

Figure 18. Outdoor Transceiver J-box Installation

3.7.2 PDA Handheld Remote Installation

1. Remove the Handheld Remote from the packaging.

2. On the back of the Handheld Remote, loosen and remove the two (2) screws that secure the cover for the battery chamber

(see Figure 19).

PDA Handheld

Remote - Back View

Two (2)

AA Batteries

Screws

Reset Switch

Figure 20. PDA Transceiver J-Box - Internal View

2. On the PDA Handheld Remote, press and hold both the UP and DOWN arrows simultaneously for three (3) seconds. After

3 seconds, the CHANNEL SETUP screen appears (see Figure 21). Select a channel.

UM-3/R6/AA

BATTERY

1.5V x 2

UM-3/R6/AA

Green

LED

Red

LED

Learn

Switch

Transceiver

PCB

Battery Chamber Cover for Battery

Chamber

Figure 19. Battery Installation on Handheld Remote

SET RF CHANNEL

RF CHANNEL: 1

Use ARROW KEYS to set the

RF CHANNEL.

Press SELECT to continue.

UP

Button

Page 19

6. On the PDA Handheld Remote display screen, a prompt will appear with instructions to slide the J-box Learn Switch out of LEARN (OFF) and to press the J-box

Reset Switch.

7. At the PCB in the Transceiver J-box, slide the Learn Switch out of LEARN and press the Reset Switch. The Red and Green LEDs on the J-box will blink simultaneously (see

Figure 22).

SELECT Button DOWN

Button

Section 4. System Startup

Figure 21. PDA Handheld Remote Channel Setup and Buttons

3. Use the UP and DOWN buttons to highlight the desired RF channel. Then press

SELECT.

4. When the RF channel is selected, the following message appears on the PDA display screen:

Set slide switch on J-Box PCB to the

LEARN MODE.

5. At the PCB in the Transceiver J-box, slide the Learn Switch to LEARN (ON). See

Figure 22.

4.1 Handheld Remote Programming

4.1.1. Basic Programming Menu

To set a particular piece of equipment to turn on and off at predetermined times, highlight MENU and press SELECT (see Figure 23). Highlight

PROGRAM and press SELECT. Use the UP or

DOWN buttons to highlight the equipment (for example, Filter Pump) then press SELECT. Follow the on-screen prompts. Use the UP or DOWN buttons to pick each number, starting with ON hours, press SE LECT to enter and move on to the next item to change, including picking what day(s) the program will run. If you make a mistake, use the BACK button to return to a number. If the program is already en tered, highlight CHANGE

PROGRAM and step through to the entry that should be cor rect ed.

Red

LED

Green

LED

Learn

Switch

Shown in Learn

Mode

- Switch

Position

On.

Reset Switch

Transceiver

PCB

Figure 22. Tranceiver J-box PCB Learn Switch

BACK

Button

SELECT

Button

HOT KEY 1

Power ON/OFF

Button

HOT KEY 2

DOWN

Button

UP

Button

Figure 23. PDA Handheld Remote Buttons

Page 20

4.1.2 Set the Time Menu

To set the time, highlight the MENU and press

SELECT. Highlight SET TIME and press SELECT

(see Figure 24). Use the UP or DOWN button to set the values. Press SELECT to continue.

MAIN MENU

HELP

PROGRAM

SET TEMP

SET TIME

PDA OPTIONS

SYSTEM SETUP

Pool/Spa Only - Highlight MENU and press

SELECT. Highlight SET TEMP and press SELECT

(see Figure 26). The message TEMP1 must be

higher than TEMP2 is displayed. Highlight TEMP1 and press SELECT. Use the UP or DOWN button to increase or decrease the temperature and press

SELECT. Highlight TEMP2 and press SELECT.

Use the UP or DOWN button to increase or decrease the temperature and press SELECT. Use the BACK button to return to the main screen.

MAIN MENU

HELP

PROGRAM

SET TEMP

SET TIME

PDA OPTIONS

SYSTEM SETUP

SET TEMP

TEMP1 80°F

TEMP2 60°F

Highlight an item and press

SELECT

Figure 24. Set Time Menu

4.1.3 Set the Temperature Menu

Pool/Spa Combination - Highlight MENU and press SELECT. Highlight SET TEMP and press

SELECT (see Figure 25). Use the UP or DOWN button to highlight either POOL or SPA and press

SELECT. Use the UP or DOWN button to increase or decrease the tem per a ture and press SELECT.

Use the BACK button to return to the main screen.

MAIN MENU

HELP

PROGRAM

SET TEMP

SET TIME

PDA OPTIONS

SYSTEM SETUP

SET TEMP

POOL HEAT 80°F

SPA HEAT 104°F

Highlight an item and press

SELECT

SET TEMP

POOL HEAT 80°F

SPA HEAT 104°F

Highlight an item and press

SELECT

SET TEMP

POOL HEAT 85°F

SPA HEAT 104°F

Highlight an item and press

SELECT

Figure 25. Set Temperature Menu - Pool/Spa

Combination

SET TEMP

TEMP1 80°F

TEMP2 60°F

Highlight an item and press

SELECT

SET TEMP

TEMP1 85°F

TEMP2 60°F

Highlight an item and press

SELECT

Figure 26. Set Temperature Menu - Pool/Spa Only

4.1.4 Label Auxiliary Functions Menu

Highlight MENU and press SELECT. Highlight

SYS TEM SETUP and press SELECT (see

Figure 27). Highlight LABEL AUX and press

SELECT. High light the AUX you want to label and press SELECT. Highlight GENERAL, LIGHT,

WA TER FALL or CUSTOM LABEL and press

SELECT. Choose a name within these categories by using the UP or DOWN button. Press SELECT when you find the correct label. Choose CUS TOM to type in your own labels.

NOTE The Auxiliary labels AIR BLOWER and FILL

LINE have an automatic 30 minute runtime.

If DIP switch 1,2 or 3 are on, auxiliaries 1, 2 and 3 are labeled CLEANER, LOW SPEED and SP ILL OVER respectively and cannot be re la beled.

Page 21

MAIN MENU

HELP

PROGRAM

SET TEMP

SET TIME

PDA OPTIONS

SYSTEM SETUP

SYSTEM SETUP

LABEL AUX

FREEZE PROTECT

AIR TEMP

DEGREES C/F

TEMP CALIBRATE

SOLAR PRIORITY

PUMP LOCKOUT

ASSIGN JVAs

MORE

AUX1

AUX2

AUX3

AUX4

AUX5

AUX6

AUX7

LABEL AUX

LABEL AUX1

CURRENT LABEL

AUX1

GENERAL LABELS

LIGHT LABELS

WTRFALL LABELS

CUSTOM LABEL

MAIN MENU

HELP

PROGRAM

SET TEMP

SET TIME

PDA OPTIONS

SYSTEM SETUP

SYSTEM SETUP

LABEL AUX

FREEZE PROTECT

AIR TEMP

DEGREES C/F

TEMP CALIBRATE

SOLAR PRIORITY

PUMP LOCKOUT

ASSIGN JVAs

MORE

FREEZE PROTECT

TEMP

Use ARROW KEYS to set value.

Press SELECT to continue

38°F

FREEZE PROTECT

DEVICES

FILTER PUMP

SPA

SOLAR HEAT

AUX1

AUX2

AUX3

MORE

X

X

LABEL AUX1

GENERAL LABELS

AUX1

AERATOR

AIR BLOWER

BACKWASH

BOOSTER PUMP

CHEM FEED

CLEANER

MORE

Figure 27. Label Aux Menu

4.1.5 Set Freeze Protection Menu

Highlight MENU and press SELECT. Highlight

SYSTEM SETUP and press SELECT (see Figure

28). Highlight FREEZE PROTECT and press

SELECT. Use the UP or DOWN button to change the temperature. Once the temperature is set press the SELECT button to move to the next screen to assign freeze protection to a selected piece of equip ment. Highlight a device and press SELECT.

"X" means the device has been assigned.

NOTE The filter pump is always assigned to freeze protection.

Figure 28. Freeze Protection Menu

4.1.6 Assign JVAs Menu

Highlight MENU and press SELECT. Highlight SYS-

TEM SETUP and press SELECT (see Figure 29).

Highlight ASSIGN JVA and press SELECT. Highlight the JVA you wish to assign and press SELECT.

NOTE If a solar sensor is installed, the Solar JVA will automatically be assigned and will be marked as USED.

MAIN MENU

HELP

PROGRAM

SET TEMP

SET TIME

PDA OPTIONS

SYSTEM SETUP

ASSIGN JVAs

INTAKE USED

RETURN USED

CLEANER FREE

SOLAR USED

SYSTEM SETUP

LABEL AUX

FREEZE PROTECT

AIR TEMP

DEGREES C/F

TEMP CALIBRATE

SOLAR PRIORITY

PUMP LOCKOUT

ASSIGN JVAs

MORE

ASSIGN

CLEANER JVA

NO ASSIGNMENT

AUX1

AUX2

AUX3

AUX4

AUX5

AUX6

Figure 29. Assign JVA Menu

Page 22

4.2 Restarting the System (Clear Memory)

Menu

To remove all labeling, programming, assignments and temperature settings, highlight MENU and press SELECT. Highlight SYSTEM SETUP and press SELECT (see Figure 30). Highlight

CLEAR MEMORY and press SELECT. Highlight

CONTINUE and press SELECT. Use the UP or

DOWN button to highlight YES or NO and press

SELECT. There will be about a 15 second delay before you see the FINISHED screen. Highlight

CONTINUE and press SELECT to return to the

SYS TEM SETUP.

MAIN MENU

HELP

PROGRAM

SET TEMP

SET TIME

PDA OPTIONS

SYSTEM SETUP

CLEAR MEMORY

WARNING

Clearing memory erases ALL stored settings.

CONTINUE

CLEAR MEMORY

ERASING

ALL

SETTINGS please wait

Figure 30. Clear Memory Menu

SYSTEM SETUP

SOLAR PRIORITY

PUMP LOCKOUT

ASSIGN JVAs

COLOR LIGHTS

SPA SWITCH

SERVICE INFO

CLEAR MEMORY

HEAT PUMP

MORE

CLEAR MEMORY

FINAL WARNING

Are you SURE that you want to

ERASE ALL

SETTINGS

??

YES

NO

CLEAR MEMORY

FINISHED

Press SELECT to continue.

CONTINUE

4.3 PDA System Defaults and General Modes

Default Temperature (Pool/Spa Combination)

Default Pool Temp = 80° F

Default Spa Temp = 102° F

Default Temperature (Pool/Spa Only)

Default TEMP1 = 80° F

Default TEMP2 = 60° F

Default Spa Side Switch Settings

Button 1 = Spa (Filter Pump for pool/spa only models)

Button 2 = Spa Heater (Temp1 pool/spa only models)

Button 3 = AUX1

Button 4 = AUX2

Default Freeze Protection Settings

Filter Pump: Freeze Protection ON.

All Other Equipment: Freeze Protection OFF

Default Activation Temperature: 38° F

NOTE If you select SPA to be freeze protected, water circulation will switch between pool and spa every 30 minutes during freezing conditions once freeze mode is active.

4.3.1 Power Center Service Switch

AUTO Mode (automatic)

1. The PDA Handheld Remote has complete control of all functions.

2. All programmed settings will operate.

3. All safety delays and equipment protection in ter locks are operational.

SERVICE Mode

1. The power center has complete control of all functions.

2. Service mode must be turned on/off at the power center.

3. No programmed settings will work.

CAUTION

In service mode, equipment protection safety interlocks are overridden.

TIMEOUT Mode

1. The power center has complete control for three (3) hours.

2. After three (3) hours the system will return to AUTO mode.

3. Programmed on/off times will be overridden during the three (3) hours.

4. After the three (3) hour "time out", the system will resume any programmed items that were overridden.

Battery Backup

A nine-volt battery is located at the power center.

The battery keeps the clock running during a power outage so the time and date will be correct when power is restored. Programming will not be lost even if the battery is dead. Do not install the battery in the power center until the system is ready to operate. Battery will drain if power is left off.

Review DI AG NOS TICS in the SYSTEM SETUP section of the menu. The DIAGNOSTICS will indicate when the battery needs replacement.

ATTENTION

Special Note to Startup Person: The

AquaLink RS PDA allows two (2) options for operating the pool equipment on the first day of operation:

Option #1 - Once all programming of equipment is completed, the AquaLink RS PDA will automatically review all programs and turn on any equipment which is programmed to be on.

Option #2 - To operate the filter pump or cleaner continually for the first day, leave the power center service button in AUTO mode.

Using the PDA Handheld Remote, turn on the filter pump or the equip ment you want to run.

NOTE If the equipment has already been turned on by a program time, turn the equipment off and then back on.

The equipment that is ac ti vat ed will run con tin u ous ly, ignoring the first programmed off time, and will turn off at the programmed off time for the next day (only if a program has been entered).

Page 23

Page 24

4.4 PDA Handheld Remote Menu Flow Chart

EQUIPMENT

ON/OFF

SELECT

EQUIPMENT

ALL OFF

ON

OFF

SERVICE

DIAGNOSTICS

MODEL

SENSORS

REMOTES

ERRORS

MENU

HELP

PROGRAM

SET TEMP

SET TIME

SET AQUAPURE

PDA OPTIONS

SELECT

EQUIPMENT

ADD PROGRAM

DELETE

CHANGE

SET MONTH, DAY,

YEAR & TIME

SET

OUTPUT %

SYSTEM

SETUP

POOL HEAT

SPA HEAT

CHILL †

2 MINUTES

5 MINUTES

10 MINUTES

LABEL AUX

AQUAPURE

AIR TEMP

DEGREES F/C

SET TIME

MODE ††

FREEZE PROTECTION

POOL

SPILLOVER

ENABLED

DISABLED

TEMP CALIBRATE SET TEMP

SOLAR HEAT PRIORITY †

PUMP LOCKOUT

ASSIGN JVAs

COLOR LIGHTS

SPA SWITCH

ENABLED

DISABLED

ENABLED

DISABLED

JANDY LIGHT

SAM/SAL LIGHT

COLOR LOGIC LIGHT

1

SERVICE INFO

CLEAR MEMORY

HEAT PUMP †

HEAT MODE

CHILL MODE

SET AUTO-OFF

BACKLIGHT

ASSIGN HOTKEYS

LIGHT ON

LIGHT OFF

1

2

SELECT

DEVICE

GENERAL LABELS

LIGHT LABELS

WTRFALL LABELS

CUSTOM LABELS

(TYPE PERSONALIZED

DESCRIPTION)

SET TEMP

SELECT

DEVICE

SELECT

LABEL

FAHRENHEIT

CELCIUS

ASSIGN TO AUX

INTAKE

RETURN

CLEANER

SOLAR

BOOST †

START

GO BACK

††

Items Seen Only With Optional Equipment

Mode Only Displayed When DIP Switch #3 is Set to ON

Page 25

Section 5. Troubleshooting

5.1 PDA Quick Troubleshooting Guide

The AquaLink RS PDA will stop communicating anytime interference (such as a 900 MHz device) prevents a valid signal transmission. When communication is lost the PDA Handheld Remote will lock on the startup screen until a good link is again achieved, usually within a few sec onds.

If com mu ni ca tion is not reestablished within a few seconds or this happens often, use the troubleshooting in for ma tion in the following table for suggestions.

Symptom Problem Possible Solution

Power Center override switches operate when in Service or

Time Out Mode, but the PDA

Handheld Remote is completely dead (no backlight on or display).

Dead batteries in the PDA

Handheld Remote.

Replace batteries.

PDA Handheld Remote backlight is on and the startup screen is displayed. The override switches at the power center operate as they should.

PDA is not communicating with the power center PCB.

Check the two center wires (black & yellow) of the four conductor cable to the transceiver

J-box. Also check the installation of the PPD on the power center PCB. If the PPD is not seated correctly the system will not communicate.

PDA Handheld Remote backlight is on and the startup screen is displayed, but override switch es at the power center do not operate at all.

1. Damaged or improperly installed PPD.

2. Wrong PPD.

3. Damaged power center

PCB.

Some buttons do not operate from the PDA Handheld

Remote, nor from the power center override switches.

System locked up.

Wrong PPD chip installed at the power center PCB.

Programs do not run at the correct time.

1. Check alignment of the PPD.

2. Make sure that the PPD is for a PDA.

3. If PPD is installed correctly, replace the power center PCB.

Ensure that the PPD revision number is the correct revision required for the application.

Microprocessor locked.

Turn off power to the system. Disconnect battery at the Power Center and turn on power.

Reconnect the battery and reset time and date.

AquaLink RS does not display correct time and date.

At the PDA Handheld Remote, set correct time and date. In Diagnostics, check battery level.

If LOW BATTERY is displayed, replace battery at the Power Center to ensure correct time and date are maintained.

Page 26

One button on the Four

Function Remote does not operate.

Symptom Problem

Check programming first. If the Four Function Remote is programmed correctly, the button may be shorted.

Possible Solution

Replace the Four Function Re mote. Use MENU,

REVIEW, SPA SWITCH to check pro gram ming.

NOTE If dip switch 1

(CLEANER) is on, button # 3 on the Four Function Remote will not operate when in spa mode unless this button is programmed to a circuit other than Aux 1.

Pool cleaner booster pump turns on without the filter pump being on, and can run with the spa on.

System is not recognizing DIP switch #1 is on.

Turn off all equipment buttons, then turn off power to the system, finally turn off, then on, DIP switch #1. Turn on power and test system.

NOTE Before turning on any

DIP switches, first turn off all equipment. Do not program any auxiliaries until all DIP switches are set.

System comes on at times that are not programmed.

Phantom programs.

At the PDA press MENU, then select

PROGRAM. Make note of all programs (the

Four Function Remote setting, labels, and temperature settings) then turn off all DIP switches and go to the PDA. CLEAR MEM O RY, reprogram and try system again.

Heater will not fire. Heater LED will not light in "Service Mode".

Water temperature sensor not installed or defective.

Check water temperature sensor.

LCD screen display stays on startup screen.

No communication between

PDA Handheld Remote and

Power Center J-box.

Change the Frequency Channel. See Section

3.7.3.

Page 27

Section 6. Power Center Wiring Diagram

Dip Switch Settings

Factory Setting

# OFF

1 Aux 1

2 1 SPD Pump

3 Aux 3

4 Cool Down

5 Normal

6 Spare Aux

(Pool Mode)

7 See Manual

8 Heater 3 min.

Off

When Turned

ON

Cleaner

2 SPD Pump

Spa Spillover

Disabled

See Manual

Spare Aux

(Spa Mode)

See Manual

Heater 5 min.

Off

4 3 2 1 6 5 4 3 2 1

To Controller

(red terminal bar)

To Remote

(brown terminal bar)

To Sensors, etc.

(green terminal bar)

Intake

JVA

Return

JVA

Cleaner

JVA

Solar

JVA

Solar

Pump

Elect.

Heater

JVA Sockets

(24 VAC output)

Relay Sockets

(24 VDC output)

FI

LTE

R

P

UMP

A

U

X

1

AU

X

2

A

UX

3

AU

X

4

AUX

5

A

U

X

6

A

UX

7

Relay Sockets (24 VDC output)

F. Pump Aux. 2 Aux. 3

Relay Sockets (24 VDC output)

Aux. 4 Aux. 5 Aux. 6

Battery

(9Volt)

Filter Pump Relay

Aux. 3 Relay

Aux. 4 Relay

Aux. 7 Relay

Aux. 1 Relay Aux. 2 Relay

Grounding Bar

Aux. 5 Relay Aux. 6 Relay

System Power

Wire Nut to

120VAC Power

Page 28

Section 7. Power Center PCB DIP

Switch Settings

IMPORTANT Do not program equipment ON/OFF times until all DIP switches are set.

7.1 DIP Switch Functions

DIP #1 ON- AUX 1 Controls Pool Cleaner

If you installed a booster pump for a pool cleaner, the relay coil for the booster pump must be plugged into the AUX 1 relay socket. If a non-booster pump cleaner is installed, plug the JVA into the cleaner JVA socket. Turn ON DIP Switch #1.

DIP #4 ON- Heater Cool Down Disabled

Turn this switch ON to disable the heater cool down safety feature on the AquaLink RS.

CAUTION

Turn this DIP Switch ON only if you are using an electric heater or a heat pump that does not retain residual heat. If you are turning this switch ON for service pur pos es, be sure to turn it back off.

turns on.

• Cleaner will not turn on until fi lter pump has been on for three (3) minutes (to ensure priming of system).

• Cleaner turns off when water circulation is to spa.

• Cleaner turns off when spa spillover feature is activated.

• Cleaner turns off for three (3) minutes when solar is activated (to ensure air is purged from the system).

• AquaLink RS PDA Handheld Remote display reads "CLEANER" rather than

"AUX 1".

DIP #2 ON- AUX 2 Controls Low Speed of Filter

Pump

Turn this switch ON if you want to control both speeds of a two-speed filter pump. With this switch on, the filter pump button on the AquaLink RS

PDA will control high speed and the HOT KEY 2

(default) button will control low speed.

IMPORTANT You must also install a Jandy Two-

Speed Relay.

DIP #3 ON- AUX 3 Controls Spa Spillover

(Operates with Pool/Spa Combination)

Turn this switch ON, and when the AUX 3 button on the AquaLink RS PDA (or Spa Side Switch) is pressed, the Return Valve Actuator will rotate to spa cir cu la tion. Because the Intake Valve Actuator does not rotate, the spa will fill with water and overflow into the pool.

NOTE Leave AUX 3 relay socket empty.

DIP #5 ON- Factory Use Only

This switch is used for calibration by Jandy certified technicians only. Please leave this switch in the OFF po si tion.

DIP #6 ON - Pool/Spa Combination Systems Only

Change Spare AUX to activate when Filter Pump is on and system is in spa mode. Spare AUX socket is on the back side of the Power Center PCB.

DIP #7 ON- Not Used

Dip #8 ON- Heat Pump Instead of Gas Heater

Turn this switch ON if you have installed a heat pump instead of a gas heater. After thermostat setting has been reached, heater will remain OFF for 5 minutes.

Page 29

Factory setting is with all DIP switches off.

4

5

6

7

8

OFF ON

1

2

3

7.2 DIP Switch Settings for Pool and Spa Combination

DIP Switch # OFF

4

5

1

2

3

6

7

8

AUX1= Pool Cleaner

ON

AUX1= any equipment

AUX2= any equipment

AUX3= any equipment

Heater cool down operates.

AUX2= Low Speed for a two-speed filter pump.

Filter pump circuit becomes High Speed.

AUX3= Spa Spillover effect- Combination controls only.

Heater cool down disabled.

Normal operation Factory adjustment- when this switch is on, temperature delays are eliminated.

Do not leave this switch in the ON position.

Spare Aux activates with Filter Pump when

Spa OFF.

Spare Aux activates with Filter pump with

Spa on.

Spare No change on Combination or Only

Controls.

After thermostat setting has been reached, heater will remain OFF for 3 minutes.

After thermostat setting has been reached, heater will remain OFF for 5 minutes.

Page 30

7.3 DIP Switch Settings for Pool or Spa Only

DIP Switch # OFF

6

7

8

3

4

5

1

2

AUX1= Pool Cleaner

ON

AUX1= any equipment

AUX2= any equipment

AUX3= any equipment

Heater cool down operates.

AUX2= Low Speed for a two-speed filter pump.

Filter pump circuit becomes High Speed.

No change

Heater cool down disabled.

Normal operation Factory adjustment- when this switch is on, temperature delays are eliminated.

Do not leave this switch in the ON position.

No change Spare

Spare No change

After thermostat setting has been reached, heater will remain OFF for 3 minutes.

After thermostat setting has been reached, heater will remain OFF for 5 minutes.

Page 31

Section 8. General, Water Feature and Light Aux Labels

General Labels

Aerator

Air Blower

Backwash

Booster Pump

Chem Feed

Cleaner

Color Wheel

Drain Line

Fan

Fiber Optic

Fill Line

Filter Pump

Floor System

Fogger

Fountain

Heat Pump

Heater

Hi-E2

High Speed

Home A/C

Home Heat

Jet Pump

Lite

Lamp

Low Speed

Mist

Music

Not Used (see note)

Ozonator

Pond

Ray-Vac

Slide

Solar Pump

Spa

Spillway

Sprinkler 1

Sprinkler 2

Sprinkler 3

Stereo

Stream

Swim Jet

Timed Aux

Valve(s)

Wtr Feature

Whirlpool

Light Labels

Shower

Shrub

South

Spa

Statue

Steps

Table

Tier

Tree

Walk

Water Ftr

Wtrfll

West

Yard

Front

Garage

Garden

Gazebo

Hall

House

Kitchen

Laminar Plsr

Left

North

Path

Patio

Perimeter

Pond

Pool

Porch

Right

Room

Sauna

Security

#1

#2

#3

Back

Basement

Beach

Bedroom

Bug

Cabana

Color Wheel

Deck

Dock

Drive

East

Entry

Equipment

Fan

Fence

Flood

Fountn

Waterfall Labels

Waterfall

Waterfall 1

Waterfall 2

Waterfall 3

Sheer Dscnt

Rockfall

Laminar Jet

NOTE Please be aware that if the label NOT USED from the GENERAL LABEL menu is used on an AUX relay, the relay will not engage.

LIMITED WARRANTY

Thank you for purchasing Jandy ® pool and spa products. Jandy Pool Products, Inc. warrants all parts to be free from manufacturing defects in materials and workmanship for a period of one year from the date of retail purchase, with the following exceptions:

• AquaLink

® RS units installed with Jandy ® Surge Protection Kits will be covered for two years.

• NeverLube

® valves are warranted for the life of pool and/or spa on which they were originally installed.

• AquaPure TM Electronic Chlorine Generator Electrolytic Cells carry a 5 year limited warranty on a prorated basis.

This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have been moved from their original installation sites. The liability of Jandy Pool Products, Inc. shall not exceed the repair or replacement of defective parts and does not include any costs for labor to remove and reinstall the defective part, transportation to or from the factory, and any other materials required to make the repair. This warranty does not cover failures or malfunctions resulting from the following:

1. Failure to properly install, operate or maintain the product(s) in accordance with our published Installation,

Operation and Maintenance Manuals provided with the product(s).

2. The workmanship of any installer of the product(s).

3. Not maintaining a proper chemical balance in your pool and/or spa [pH level between 7.2 and 7.8, Total

Alkalinity (TA) between 80 to 120 ppm, Total Dissolved Solids (TDS) less than 2000 not including salt ppm].

4. Abuse, alteration, accident, fire, flood, lightning, rodents, insects, negligence or acts of God.

5. Scaling, freezing, or other conditions causing inadequate water circulation.

6. Operating the product(s) at water flow rates outside the published minimum and maximum specifications.

7. Use of non-factory authorized parts or accessories in conjunction with the product(s).

8. Chemical contamination of combustion air or improper use of sanitizing chemicals, such as introducing sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer.

9. Overheating; incorrect wire runs; improper electrical supply; collateral damage caused by failure of O-Rings,

DE grids, or cartridge elements; or damage caused by running the pump with insufficient quantities of water.

LIMITATION OF LIABILITY:

This is the only warranty given by Jandy Pool Products, Inc. No one is authorized to make any other warranties on behalf of Jandy Pool Products, Inc. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,

EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF FITNESS

FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. JANDY POOL PRODUCTS, INC. EXPRESSLY

DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL, INCIDENTAL, INDIRECT OR

PUNITIVE DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY. This warranty gives you specific legal rights. You may also have other rights which vary by state or province.

WARRANTY CLAIMS:

For prompt warranty consideration, contact your dealer and provide the following information: proof of purchase, model number, serial number and date of installation. The installer will contact the factory for instructions regarding the claim and to determine the location of the nearest designated service center. If the dealer is not available, you can locate a service center in your area by visiting www.jandy.com or by calling our technical support department at (707) 776-8200 extension 260. All returned parts must have a Returned Material

Authorization number to be evaluated under the terms of this warranty.

ETL LISTED

CONFORMS TO

UL STD 1563

CERTIFIED TO

CAN/CSA C22.2 NO. 218.1

PDA HANDHELD REMOTE

FCC ID: S8F826X

PDA TRANSCEIVER

FCC ID: S8F8252

Jandy Pool Products, Inc.

6000 Condor Drive • Moorpark, CA USA 93021 • 707.776.8200 • Fax 707.763.7785

Lith i U S A © W t ik T h l i 0401

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Controls pool and spa combinations or individual systems
  • Monitors and adjusts water temperature, filtration, and sanitization
  • Provides remote access and control via a handheld remote or optional app

Related manuals

Frequently Answers and Questions

What are the system component specifications?
Refer to Section 2.2 of the Installation Manual for detailed specifications on the power center, transceiver, and handheld remote.
How do I connect the heater?
Follow the instructions in Section 3.4 of the Installation Manual for proper heater connection.
What are the DIP switch settings for a pool and spa combination?
Refer to Section 7.2 of the Installation Manual for the correct DIP switch settings for a pool and spa combination system.