Pentax R-300 R-315(N), R-325(N), R-335(N), R-322(N), R-323(N), R326 Electronic Total Station Instruction Manual
PDF
নথি
বিজ্ঞাপন
বিজ্ঞাপন
® Instruction Manual Electronic Total Station R-300 SERIES R-315(N)/R-325(N)/R-335(N)/R-322(N)/R-323(N)/R326 Special Functions PSF Software Ver.365 PENTAX Industrial Instruments CO., Ltd. Document Ver. 1.10 PSF Software Ver.365 Copyright Copyright © 2002 PENTAX Industrial Instruments Co., Ltd. All Rights Reserved PENTAX Industrial Instruments Co., Ltd. is a sole proprietor of the PSF software. The PSF software and publication or parts thereof, may not be reproduced in any form, by any method, for any purpose. PENTAX Industrial Instruments Co., Ltd. makes no warranty, expressed or implied, including but not limited to any implied warranties or merchantability or fitness for a particular purpose, regarding these materials and makes such materials available. Document Ver.1.10: July 2004 Before using this product, be sure that you have thoroughly read and understood this instruction manual to ensure proper operation. After reading this manual, be sure to keep in a convenient place for easy reference 1 PSF Software Ver.365 Display and Keyboard The display and keyboard of the R-300 series are described below. . Alphanumeric & +/- key Power supply key Functions keys Illumination key ESC key Laser plummet & Electronic vial key Operation Keys Key POWER [ESC] Illumination [ENT] [Laser] Alphanumeric [HELP] Description ON/OFF of power supply Returns to previous screen or cancels an operation. Turns the illumination of the LCD display and telescope reticle on and off. Accepts the selected , hilighted, choice or the displayed screen value. Displays the laser plummet *1, Electronic vial function, and the LD point screen when you push the laser plummet/electronic vial key. (Refer to “2-5 LD POINT", “3-2 Laser plummet", and “3-5 Leveling with Electronic vial"). *1:Only the product with the Laser plummet function At the numerical value screen, the numerical value and the sign '.' displayed are input. The English characters printed right under numeric of each key are input. Pressing [lLLU]+[ESC] key causes a help menu to appear in A MODE or B MODE or causes a help message to appear. Function Keys 2 PSF Software Ver.365 Display F Key Description Mode A [MEAS] F1 [MEAS] F1 [TARGET] [0 SET] [DISP] F2 F3 F4 [MODE] F5 Pressing this key one-time measures the distance and measurement type can be selected by Initial Setting 2. Pressing this key twice measures the distance and another measurement type can be selected by Initial Setting 2. Select whether the target is SHEET/PRISM/REFRECTORLESS.) Resets the horizontal angle to 0° 0' 0" by pressing twice. Toggles the display composition in the order "H.angle/H.dist./V.dist.", "H.angle/V.angle/S.dist.", and “H.angle/V.angle/H.dist./S.dist./V.dist". Toggles the screen between MODE A and MODE B. [S.FUNC ] F1 PSF Special Functions [ANG SET] [HOLD ] F2 F3 Brings up the angle setting screen for setting angle-related parameters (ANGLE, %GRADE, H.ANGLE INPUT and R/L REVERSE). Pressing this key twice retains (holds) the horizontal angle shown on the display. [CORR ] F4 [MODE ] F5 Mode B Brings up the screen for changing the Target constant, Temperature, Pressure setting Toggles the screen between MODE A and MODE B. Other functions [← ←] [→ →] [△ △] [▽ ▽] RETICLE [↑ ↑] LCD [↓ ↓] ILLU [CLEAR] [SELECT] F1 F2 F1 F2 F3 F3 F4 F4 F5 F5 F5 Moves the cursor to the left. Moves the cursor to the right. Goes back five Items on the screen Goes forward five items on the screen. Changing the Reticle illumination when pressing Illumination key Moves the cursor up Changing the LCD contrast when pressing Illumination key Moves the cursor down Changing the LCD illumination when pressing Illumination key Clears the figure Opens the selection window Alphanumeric Input The point name is inputted by the Alphanumeric keys as following. Key [ 0 ] [ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ] [ 7 ] [ 8 ] [ 9 ] [ . ] [+/-] Letter under Key PQRS TUV WXYZ GHI JKL MNO ABC DEF Letter & Figure sequential order to input [@][.][_][-][:][/][0] [P][Q][R][S][p][q][r][s][1] [T][U][V][t][u][v][2] [W][X][Y][Z][w][x][y][z][3] [G][H][I][g][h][i][4] [J][K][L][j][k][l][5] [M][N][O][m][n][o][6] [ ][?][!][_][ ][^][|][&][7] [A][B][C][a][b][c][8] [D][E][F][d][e][f][9] [.][,][:][;][#][(][)] [+][-][*][/][%][=][<][>] Memories in the Instrument This instrument incorporates not only 8 measuring programs but also a MEMORY MANAGER program as special functions and so it can receive and record Coordinates data and surveying 3 PSF Software Ver.365 data of maximum 7500 points. Relations between memories and each Special function Special Function Memory Data to be read Data to be stored DATA STORAGE Yes Job name Job name, Station P.*1Measured P.*1 COORDINATES Yes COORD. STAKEOUT Yes OFFSET SHOTS Yes RESECTION Yes Job name, Station P.*2 Backsight P. Job name, Station P.*2 Backsight P., Stakeout P. Job name, Station P.*2 Backsight P. Job name, Known P. A,B,C Job name, Station P.*2 Backsight P., Measured P.*2 Job name, Station P.*2 Backsight P., Stakeout P. Job name, Station P.*2 Backsight P., Target P. Job name, Station P.*2 Known P. A,B,C RDM ----- ----- ----- REM ----- ----- ----- DISTANCE STAKEOUT ----- ----- ----- MEMORY MANAGER Yes (Yes) (Yes) Each data contents Station P.*1 Station P.*2 Backsight P. Stakeout P. Target P. Known P. Measured P.*1 Measured P.*2 Station P. No. Description Instrument H. Target C. Temperature Pressure ppm Correction value P. No. Coordinate Description P. No. Coordinate Description P. No. Coordinate Description P. No. Coordinate Description P. No. Coordinate Description P. No. Prism H. H. Angle V. Angle S. Distance Description P. No. Coordinate Description 4 PSF Software Ver.365 CONTENTS Copyright Display and Keyboard Memories in the Instrument Relations between memories and each function 7 7 7 1 INTRODUCTION 1-1 INTRODUCTION 1-2 BEFORE USING THE PSF MANUAL 2 ACCESSING THE SPECIAL FUNCTIONS 2-1 ACCESSING BY SPECIAL KEY 2-2 ACCESSING BY HELP KEY 2-3 ACCESSING BY 007 8 8 9 10 3 COORD. STAKEOUT General pictures of measurement Detailed Operating procedures 1. JOB NAME 2. STATION SETUP 3. STAKEOUT 11 11 12 12 14 19 4 DISTANCE STAKEOUT General pictures of measurement Detailed Operating procedures 23 23 24 5 RDM General pictures of measurement Detailed Operating procedures 6 COORDINATES 25 25 26 General pictures of measurement Detailed Operating procedures 1. JOB NAME 2. STATION SETUP 3. SURVEY 27 27 27 27 28 30 7 OFFSET SHOTS General pictures of measurement Detailed Operating procedures 1. JOB NAME 2. STATION SETUP 3. SURVEY 8 REM General pictures of measurement 31 31 32 32 32 34 Detailed Operating procedures 5 35 35 PSF Software Ver.365 9 RESECTION General pictures of measurement Detailed Operating procedures 1. JOB NAME 2. STATION SETUP 3. SURVEY 10 DATA STORAGE 40 40 40 40 41 41 General pictures of measurement General picture 1. JOB NAME 2. STATION SETUP 3. SURVEY 11 MEMORY MANAGER Detailed Operating procedures 1. COORDINATES SEND 2. COORDINATES RECEIVE 3. COORDINATES EDIT 4. COORDINATES DELETE 5. SURVEY DATA SEND 6. SURVEY DATA EDIT 7. SURVEY DATA DELETE 42 42 42 43 44 44 45 46 47 12 DataLink DL- 01 Software 6 PSF Software Ver.365 1 INTRODUCTION 1.1 INTRODUCTION Thank you for your first looks at PSF by reading this manual. The PSF is a user friendly data collection and calculation program for the PENTAX total station R-300 series. The PSF is developed based on the PCS-300 Special functions, which is known as versatile on-board software for PENTAX PCS-300 total station series. The optimum combination of PCS-300 and R-300 hardware makes PSF as an easy and useful fieldwork tool. The main menu offers you the following possibilities. COORD. STAKEOUT DISTANCE STAKEOUT RDM COORDINATES OFFSET SHOTS REM RESECTION DATA STORAGE MEMORY MANAGER 1.2 BEFORE USING THE R-300 PSF software MANUAL The PSF manual mainly describes the R-300 special functions, and the basic operations are described in the (basic) R-300 manual. And, therefore, refer to the R-300 basic manual regarding the R-300 general instrument operations. Before performing PSF functions, select the Target type, “Reflector Sheet” or “Prism” or “Reflectorless”. General pictures of measurement: This illustrates the content of the program. Detailed Operating procedures: This describes the actual detailed operating procedures. Since detailing the Operating procedures of each program would cause unnecessary complexity, this manual shows detail for "Coordinate Stakeout Measurement" only, as an example. Descriptions of the other programs are simplified. The guide messages, however, of each step of the operation help you to proceed in a proper manner for the other programs. We are confident, therefore, that you will be able to use the other application programs once you're familiar with the operation of "Coordinate Stakeout Measurement" program. Press the keys, which are drawn by the index finger. For further information, please contact your local Pentax Authorized dealer. 7 PSF Software Ver.365 2 ACCESSING THE SPECIAL FUNCTIONS 2-1 ACCESSING BY SPECIAL KEY Example: COORD. STAKEOUT 1 Pentax Special Function Press the [S.FUNC] key at mode B. (Mode A must be changed to mode B by pressing the [MODE] key.) 1.DATA STORAGE 2.COORDINARES 3.COORD.STAKEOUT 4.OFFSET SHOTS 5.RESECTION 2 Pentax Special Function Move the cursor to 3.COORD.STAKEOUT 1.DATA STORAGE 2.COORDINARES 3.COORD.STAKEOUT 4.OFFSET SHOTS 5.RESECTION by pressing [ ∆ ], [ ∇ ] or [ ↑ ], [ ↓ ]key. 3 COORD.STAKEOUT 1. JOB NAME 2. STATION SET UP 3. STAKEOUT The COORD.STAKEOUT can be accessed by pressing the [ENT] key. Other Pentax Special Function are: Pentax Special Function 5. RESECTION 6. RDM 7. REM 8. DIST STAKEOUT 9. MEMORYMANAGER 8 PSF Software Ver.365 2 ACCESSING THE SPECIAL FUNCTIONS 2-2 ACCESSING BY HELP KEY Example: COORD. STAKEOUT 1 HELP Press the [ESC] key while pressing the [lLLU] at mode A or B. 1.HELP 2.401 TARGET CONST 3.402 ATM CORR : AUTO 4. 501 MEAS.MIN DISP: COARSE. 5. 502 SHOT COUNT SELECT The HELP menu is displayed. 2 HELP 28. 109 COORD. STAKEOUT 29. 112 REM 30. 113 RESECTION 31. 119 DATA STORAGE 32. 200 MEMORY MANAGER Move the cursor to 28. COORD.STAKEOUT by pressing [ ∆ ], [ ∇ ] or [ ↑ ], [ ↓ ] key. SELECT 3 COORD.STAKEOUT 1. JOB NAME 2. STATION SET UP 3. STAKEOUT The COORD. STAKEOUT can be accessed by pressing the [SELECT] at F5 key. 9 PSF Software Ver.365 2 ACCESSING THE SPECIAL FUNCTIONS 2-3 ACCESSING BY 007 Example: COORD. STAKEOUT 1 007 Press numeric keys of 0-0-7 to enter Command input screen on MODE A or B. H.angle H.dst V.dst 92° 35' 20" 000 CLEAR 2 007 Press the numeric key 1- 0- 9 of COORD. STAKEOUT. H.angle H.dst V.dst 3 92° 35' COORD.STAKEOUT 1. JOB NAME 2. STATION SET UP 3. STAKEOUT Special function COORD.STAKEOUT can be accessed by pressing the [ENT] key. The PSF Command No. list Special Functions Distance Stakeout RDM Coordinates Offset Shots Coord. Stakeout REM Resection Data Storage MEMORY MANAGER 007 Command 101 103 104 105 109 112 113 119 200 10 20" 109 PSF Software Ver.365 3 COORD. STAKEOUT General pictures of measurement With COORD. STAKEOUT measurement, "Stakeout point coordinates" can be staked out in 3 dimensions based on the known "Station point coordinates" and the "Backsight point coordinates or Backsight point azimuth". The horizontal angle, horizontal distance and vertical distance to the stakeout point are automatically calculated as design values, and the differences between the measured values and design values are displayed as deviations. When the coordinate values of the Station point, Backsight point and Stakeout point are recorded on the instrument memory, designation of each measured point number makes it possible to omit the each time coordinates value input. General pictures Z N Prism height Backsight point Staking point Instrument height Station point E Design values and deviation N Z Distance deviation Prism Z deviation Horizontal distance design value Staking point Prism Horizontal angle design value Station point Staking point Horizontal angle deviation Backsight point Z design value Backsight point azimuth Station point E E 11 PSF Software Ver.365 3 COORD. STAKEOUT Detailed Operating procedures Access the COORD. STAKEOUT according to the "1. ACCESSING THE SPECIAL FUNCTIONS". 1. JOB NAME (1) JOB NAME input 1 COORD.STAKEOUT Press the [ENT] key to view COORD. STAKEOUT screen. 2 For example, "XXXX" is inputted. Press the [ENT] key to view JOB NAME INPUT screen. 1. JOB NAME 2. STATION SET UP 3. STAKEOUT JOB NAME INPUT 1. Press the [ENT] key to view JOB NAME screen. JOB NAME Input the JOB NAME “XXXX” by pressing the Alphanumeric keys and arrow key. XXXX BS 3 Press the [ENT] key to enter. CLEAR TO 123 STATION NUMBER LIST 1. 000 : Maximum 15 letters can be inputted on the JOB NAME input. When the same JOB NAME is already stored, the stored one is displayed after pressing the [ENT] key at the Operating procedure 3. "The same job name is found" is displayed. 12 PSF Software Ver.365 3 (2) JOB NAME selection 1 COORD. STAKEOUT Press the [ENT] key. 2 For example, stored "3.BBBB" is selected. 1. JOB NAME 2. STATION SET UP 3. STAKEOUT JOB NAME INPUT 1. : 2. XXXX 3. BBBB 4. CCCC 5. DDDD Move the cursor to "3. BBBB" by pressing the [ ∆ ], [ ∇ ], [ ↑ ], [ ↓ ] keys and press the [ENT] key. Press the [ENT] key to enter. JOB NAME INPUT 1. : 2.AAAA 3.BBBB 4. CCCC 5. DDDD COORD. STAKEOUT 1. JOB NAME 2. STATION SET UP 3. STAKEOUT The JOB NAME selection is possible only when some NAME are already stored. 13 COORD. STAKEOUT PSF Software Ver.365 3 2. STATION SETUP (1) Station Coordinates a. Station Coordinates input 1 COORD.STAKEOUT Move the cursor to 2. STATION SETUP. 2 1. JOB NAME 2. STATION SET UP 3. STAKEOUT STATION NUMBER LIST 1. 0000 Press the [ENT] key to view the STATION NUMBER LIST screen. 3 Press the [ENT] key to view the POINT NUMBER screen. POINT NUMBER 1. 1234 For example "1234" is inputted. Input the "1234" by pressing the numerical keys. CLEAR 14 COORD. STAKEOUT PSF Software Ver.365 3 4 Press the [ENT] key to view the STATION COORDINATES INPUT screen. STATION COORDINATES INPUT 2.DESCRIPTION 3.X COORD. 4.Y COORD. 5.Z COORD. 6.INST. H STORE 5 : : 000000.000m : 000000.000m : 000000.000m : 00.000m SELECT STATION COORDINATES INPUT For example, X COORDINATE "-123456.890" is inputted as following. Move the cursor to 3. X and press the [SELECT] key at F5 to input the X COORDINATE. 6 2.DESCRIPTION 3.X COORD. 4.Y COORD. 5.Z COORD. 6.INST. H STORE : : 000000.000m : 000000.000m : 000000.000m : 00.000m SELECT X COORD. Press the numerical key , +/- and point key and input the above figures. 2.DESCRIPTION : 3.X COORD. : 000000.000m 4.Y COORD. : 000000.000m 5.Z COORD. : 000000.000m 6.INST. H : 00.000m -123456.890 m Press the [ENT] key to go to Y COORD. CLEAR 7 Input the Y and Z COORDINATE and INST. H and press the [ENT] key. STATION COORDINATES INPUT 2.DESCRIPTION 3.X COORD. 4.Y COORD. 5.Z COORD. 6.INST. H STORE : : - 123456.890 m : 12345.789 m : 123.678 m : 00.000 m SELECT 8 The STATION COORDINATE which is input: For store -Press the [STORE] key. Not for store-Press the [ENT] key. STATION COORDINATES INPUT 2.DESCRIPTION 3.X COORD. 4.Y COORD. 5.Z COORD. 6.INST. H STORE 15 : : - 123456.890 m : 12345.789 m : 123.678 m : 1.3000 m SELECT COORD. STAKEOUT PSF Software Ver.365 The BACKSIGHT SELECTION screen is viewed. BACKSIGHT SELECTION 1. COORDINATES INPUT 2.FORESIGHT COORD.(AZIMUTH) INPUT Articles marked by * are not changed. DESCRIPTION input: Press the [SELECT] key, and input letters or marks. Maximum 8 letters can be inputted at the "DESCRIPTION". b. Search and call of the stored Station Coordinates 1 Move the cursor to 2 STATION SETUP. 2 STATION NUMBER LIST Press the [ENT] key to view the STATION NUMBER LIST screen. 3 COORD.STAKEOUT 1. JOB NAME 2. STATION SET UP 3. STAKEOUT 1. 0000 2. 1234 3. 0564 4. 0678 Stored "1234" is searched for example. Move the cursor to "2. 1234" by pressing the [ ∆ ], [ ∇ ], [ ↑ ], [ ↓ ] keys and press the [ENT] key to view the INSTRUMENT HEIGHT INPUT screen. Pre-stored data in the Coordinate memory is displayed. STATION NUMBER LIST 1. 0000 2. 1234 3. 0564 4. 0678 INSTRUMENT HEIGHT INPUT 2.DESCRIPTION : * 3.X COORD. : * 113456.890 m 4.Y COORD. : * 22345.789 m 5.Z COORD. : * 323.678 m 6.INST. H : 1.5000 m SELECT 16 PSF Software Ver.365 4 BACKSIGHT SELECTION Confirm the called STATION P. COORDINATES and then press the [ENT] key. When the INSTR. H. change is needed, change the height value, and press the [ENT] key to view the BACKSIGHT SELECTION screen. 1. COORDINATES INPUT 2.FORESIGHT COORD.(AZIMUTH) INPUT (2) Backsight Selection a. Coordinates input The Backsight Point Number and Coordinates input 1 BACKSIGHT SELECTION 1. COORDINATES INPUT 2.FORESIGHT COORD.(AZIMUTH) INPUT 2 BACKSIGHT NUMBER LIST Push the [ENT] key at "1.COORDINATES INPUT". 1. 0000 BACKSIGHT NUMBER LIST screen is viewed. 3 Press the [ENT] key to view the POINT NUMBER screen. POINT NUMBER 1. Input the Backsight point number according to the STATION P.NUMBER input. 0025 CLEAR Press the [ENT] key to view the BACKSIGHT screen. COORDONATES INPUT 17 PSF Software Ver.365 4 Input the Backsight Coordinates according to the COORDINATES input. BACKSIGHT COORDONATES INPUT 1. POINT No. * 0025 2.DESCRIPTION : 3.X COORD. : -xxxxxx.xxx m 4.Y COORD. xxxxxx.xxx m 5.Z COORD. : xxxxxx.xxx m STORE SELECT 5 Press the [ENT] key to view the FORESIGHT NUMBER LIST screen after aiming at the Backsight Point. BACKSIGHT AIMING After aiming the Backsight Point, push the ENT. 6 FORESIGHT NUMBER LIST 1. 0000 2. 1234 3. 0025 Maximum 4 digits can be inputted on the Backsight number input. Search and Call of the stored Backsight Point Number 1 BACKSIGHT SELECTION Press the [ENT] key on 1 COORDINATES INPUT to view the BACKSIGHT NUMBER LIST screen . 2 Move the cursor to your desired Backsight Point Number. 3 Confirm the Backsight Point Coordinates and press the [ENT] key. 1. COORDINATES INPUT 2.FORESIGHT COORD.(AZIMUTH) INPUT BACKSIGHT NUMBER LIST 1. 0000 2. 1234 3. 0025 BACKSIGHT AIMING After aiming the Back Sight Point, push the ENT After aiming at the Backsight Point, push the [ENT] key to view the FORESIGHT NUMBER LIST screen. 18 PSF Software Ver.365 4 FORESIGHT NUMBER LIST 1. 0000 2. 1234 3. 0025 b. Azimuth angle input 1 BACKSIGHT SELECTION Move the cursor to 2. FORESIGHT COORD. (AZIMUTH) INPUT and press the 1. COORDINATES INPUT 2.FORESIGHT COORD.(AZIMUTH) INPUT [ENT] key, and go to the Operating procedures 2 of 3. STAKEOUT. FORESIGHT NUMBER LIST 1. 0000 2. 1234 3. 0025 The Azimuth angle input is performed at the Operating procedures 1) - 3) of BACKSIGHT SELECTION screen in 3. STAKEOUT. 3. STAKEOUT (1) Input and Stakeout of Foresight Point Number and Coordinates 1 Move the cursor to 3. STAKEOUT. COORD. STAKEOUT 1. JOB NAME 2. STATION SET UP 3. STAKEOUT 2 FORESIGHT NUMBER LIST Press the [ENT] key. 1. 0000 2. 1234 3. 0025 19 PSF Software Ver.365 3 Input the Foresight point number. 4 FORESIGHT COORDINATES INPUT Input the Foresight point Coordinates. 2.DESCRIPTION 3.X COORD. 4.Y COORD. 5.Z COORD. 6.INST. H For store: : Press the [STORE]. Not for store: Press the [ENT]. : : xxxxxx.xxx m : xxxxx.xxx m : xxx.xxx m : x.xxx m STORE SELECT 5 Press the [ENT] key to view the ANGLE COMPARE screen. ANGLE COMPARE DESIGN 90° 00' 00" H.angle 0° 00' 00" DEVIATE - 90° 00' 00" H.INPUT 0 SET ANG/DIST “BACKSIGHT SELECTION” screen explanation: Go to Input or Call of BACKSIGHT NUMBER LIST in case of 1. COORDINATES INPUT selection of the BACKSIGHT SELECTION screen. Go to the Operating procedures 2. FORESIGHT NUMBER LIST of 3. STAKEOUT in case of 2. FORESIGHT COORD. (AZIMUTH) INPUT selection of the BACKSIGHT SELECTION screen. BACKSIGHT SELECTION 1. COORDINATES INPUT 2.FORESIGHT COORD.(AZIMUTH) INPUT 1) H. ANG INPUT Aim at the Backsight point and input the AZIMUTH angle in case of 2. FORESIGHT COORD. (AZIMUTH) INPUT selection. 000° 00' 00" Press the [H. INPUT] at F2 key. 2) H. ANG INPUT For example, input the 225° 00' 00" . 000° 20 00' 00" PSF Software Ver.365 3) Press the [ENT] key. ANGLE COMPARE DESIGN H.angle DEVIATE 90° 00' 00" 0° 00' 00" - 90° 00' 00" H.INPUT 0 SET ANG/DIST 6 Rotate the instrument horizontally and stop it where the displayed DEVIATE becomes 0 and fix the horizontal rotation. ANGLE COMPARE DESIGN H.angle DEV.IATE 90° 00' 00" 90° 00' 00" 00° 00' 00" H.INPUT 0 SET ANG/DIST 7 DIST. COMPARE Press the [ANG/DIST] at F4 key. H.dst DESIGN 360.555 m Z coord.DESIGN 0.000 m H.dst DEVIAT Z coord.DEVIAT S.dst MEAS TRACK TARGET ANG/DST 8 DIST. COMPARE Move the prism toward the aiming direction of a telescope, and press the [TRACK] at F2 key and aim at the prism. H.dst DESIGN 360.555 m Z coord. DESIGN 0.000 m H.dst DEVIAT -2.835 m Z coord. DEVIAT -0.242 m S.dst 378.452 m MEAS TRACK TARGET ANG/DIST 9 DIST. COMPARE The DEVIATE value approaches to 0, and then press the [MEAS] at F1 key. Find a place where the DEVIATE value becomes exactly 0, and the place is the STAKEOUT POINT. The STAKEOUT of the first STAKEOUT POINT is completed. 10 Press the [ENT] key. The Stakeout of the second or third Stakeout point is performed in the same way. H.dst Z coord. H.dst Z coord. S.dst DESIGN DESIGN DEVIAT DEVIAT 360.555 m 0.000 m 0.000 m 0.000 m 378.452 m MEAS TRACK TARGET ANG/DST FORESIGHT NUMBER LIST 1. 0000 21 PSF Software Ver.365 At the procedure 6, the 00" of the DEVIATE.value can be easily got if the minimum count is set to 1 ". At the procedure 8, a prism can be easily tracked if a position is searched using the [TRACK] function and then using the [MEAS] function. (2) Search and Call of the stored Foresight Point Number 1 COORD.STAKEOUT Move the cursor to 3. STAKEOUT 1. JOB NAME 2. STATION SET UP 3. STAKEOUT 2 Press the [ENT] key. FORESIGHT NUMBER LIST 1. 0000 2. 1234 3. 0025 3 Search for the desired Foresight point number. 4 ANGLE COMPARE Confirm the called Foresight Coordinates and press [ENT] key. If the prism height change is necessary, press the [ENT] key after the change. DESIGN H.angle DEVIATE. 90° 00' 00" 0° 00' 00" - 90° 00' 00" H.INPUT 0 SET ANG/DIST 22 PSF Software Ver.365 4 DISTANCE STAKEOUT General pictures of measurement With DISANCE STAKEOUT measurement, the deviation between the input design values (specified distance) and the distance to the prism is displayed, making it easier to stake a point. General pictures Slope distance design value Stakeout Point Elevation design value Station Point Horizontal distance design value Design values and deviation Deviation Deviation Slope distance measured value Stakeout Point Elevation measured value Station Point Deviation Horizontal distance measured value 23 PSF Software Ver.365 4 DISTANCE STAKEOUT Detailed Operating procedures Access the DISTANCE STAKEOUT according to "1. ACCESSING THE SPECIAL FUNCTIONS". Step 1 Selecting the distance to be displayed and inputting the design values. (1) DISTANCE STAKEOUT ENT 1 .H.dist. ENT DIST COMPARE * Step 2 (1) SELECT Input H.dist. To Step 2 Input the S.dist. and V.dist. in the same way. STAKEOUT start TRACK / MEAS Move the prism to the ground point where the deviation is "0" (2) Use the ground point where the deviation is "0" as the STAKEOUT point (3) Use the [ENT] key to exit the STAKEOUT function Go back to Step 1 If necessary, repeat the measurement Use the [ESC] key to exit the distance stake-out function A prism can be easily tracked if a position is searched by using a [TRACK] function and then using a [MEAS] function. 24 PSF Software Ver.365 5 RDM General pictures of measurement With RDM measurement, the horizontal distance, the slope distance, difference in height and the percentage of slope between the reference point and the observation point are measured. The distance between one observation point and another observation point is measured as well. General Pictures Slope distance Target Slope % Height difference Reference Point Horizontal distance Station Point REF.P-P P-P P-P P-P Target Target Reference Point Target REF.P.-P REF.P.-P REF.P.-P Target REF.P.-P 25 PSF Software Ver.365 5 RDM Detailed Operating procedures Access the RDM according to "1. ACCESSING THE SPECIAL FUNCTIONS". Step 1 Observation of the reference point (1) PRISM H ENT INPUT PRIZM H ENT MEAS Display the distance to the Reference Point Go to Step 2 Step 2 Observation of the target point (P1) (1) PRISM H INPUT PRISM H Display the distance to P1 (2) PRISM H ENT INPUT PRISM H Display the distance to ENT ENT MEAS Display the distance between the reference point and P1 ENT ENT MEAS Display the distance between the reference point and P2, and the distance between P1 and P2 ENT *Use [DIST] key to change the distance display (REF-P/P-P) (3) PRISM H INPUT PRISM H Display the distance to Px ENT ENT MEAS Display the distance between the reference point and Px, and the distance between P (x-1) and Px * Use [DIST] key to change the distance display (REF-P/P-P) The slope that can be calculated and displayed with the RDM function is within +/-200.00 %. The difference in height is indicated in +/-. 26 PSF Software Ver.365 6 COORDINATES General pictures of measurement Any desired Target coordinates can be determined and stored by setting a Station Point as an original point and inputting the Backsight coordinate in COORDINATES measurement. The coordinates values from Original coordinates point can be determined by the Station coordinates input even if the Station Point is not set as original point. Coordinates values input can be omitted by designating the Station Point No. whenever the Station coordinates are stored in the internal memory. General pictures Z N Target Backsight Point Target Station Point E Detailed Operating procedures Access the COORDINATES according to " ACCESSING THE SPECIAL FUNCTIONS ". 1. JOB NAME (1) JOB NAME input 1.JOB NAME ( Selection keys: ⇐, ⇒, ⇑, ⇓ ) ENT COORDINATE JOB NAME INPUT JOB NAME input by pressing selection keys (2) ENT ENT JOB NAME selection ( Selection keys: ∆, ∇, ⇑, ⇓ ) 1. JOB NAME ENT COORDINATES JOB NAME INPUT Select the JOB NAME byshift keys ENT To the primaryscreen of the COORDINATES The JOB NAME can be selected only when the JOB NAMES are already stored. 27 PSF Software Ver.365 6 COORDINATES 2. STATION SETUP (1 ) STATION COORDINATES a. STATION COORDINATES input 2. STATION SETUP ENT STATION P.NUMBER LIST ENT STATION COORDINATES INPUT ENT X COORDINATE STATION P.NUMBER INPUT 2. DESCRIPTION SELECT SELECT Input X COORDINATE ENT Y COORDINATE SELECT Input Y COORDINATE ENT Z COORDINATE SELECT Input Z COORDINATE ENT INSTR. H. Input INSTR. H. DESCRIPTION INPUT SELECT ENT STORE BACKSIGHT SELECTION ENT Maximum 4 digits can be inputted at STATION P.NUMBER. Please press the [STORE] key to store the input data. Maximum 8 letters can be inputted at the "DESCRIPTION”. b. Search and call of stored STATION COORDINATES 2. STATION SETUP ENT ENT STATION P.NUMBER LIST INSTR.H. Confirm the STATION COORDINATES values Input the INSTR. H. ENT STATION P.NUMBER by shift keys SELECT BACKSIGHT SELECTION The INSTR.H. can be changed. (2) BACKSIGHT SELECTION a. COORDINATES INPUT BACKSIGHT P. NUMBER and COORDINATES input BACKSIGHT SELECTION 1 . COORDINATES INPUT BACKSIGHT P. NUMBER LIST BACKSIGHT COORDINATES INPUT ENT Input the P.No 2. DESCRIPTION SELECT ENT ENT DESCRIPTION INPUT X COORDINATE SELECT Input X COORDINATE ENT Y COORDINATE SELECT Input Y COORDINATE ENT Z COORDINATE SELECT Input Y COORDINATE ENT 28 ENT PSF Software Ver.365 6 STORE Aim at the Backsight Point ENT SURVEY ENT Maximum 4 digits can be inputted at the BACKSIGHT P. NUMBER. Please press the STORE key to store the input data. Search and call of the stored BACKSIGHT P. NUMBER BACKSIGHT SELECTION 1. COORDINATES INPUT BACKSIGHT P. NUMBER ENT Select by shift keys ENT Confirm the BACKSIGHT P. COORDINATES values ENT Aim at the Backsight point ENT SURVEY Shift keys: ( ∆, ∇, ⇑, ⇓ ) b. AZIMUTH input BACKSIGHT SELECTION 2. AZIMUTH INPUT Aim at the Backsight point Press F5 (1/2) AZIMUTH INPUT Press F5 (2/2) ENT "Aim at the Backsight point" is not displayed. 29 ENT Press H. INPUT COORDINATES PSF Software Ver.365 6 COORDINATES 3. SURVEY (1) 3. SURVEY ENT 1. POINT No. 2. DESCRIPTION 3. PRISM H. Measure the P1 Press the [POINT] key SELECT POINT No. input SELECT SELECT MEASURED POINT 1.POINT No. 2.DESCRIPTION 3.PRISM H ENT DESCRIPTION INPUT PRISM H. input ENT XYZ COORDINATES are displayed ENT ENT STORE / ENT Maximum 4 digits can be inputted at the POINT NUMBER. Please press the [STORE] key to store the measured data. The PRISM H. can be changed. (2) POINT P2 P3, P4, -Px are measured in the same way. (3) SURVEY is completed by ESC key. If necessary, repeat the measurement. The COORDINATES is completed by pressing the ESC key. 30 PSF Software Ver.365 7 OFFSET SHOTS General pictures of measurement OFFSET SHOTS can be used when the Prism cannot be positioned because of an obstacle in the way. With this type of measurement, the Target coordinates are measured and stored indirectly. Coordinates values input can be omitted by designating the Station point number whenever the Station coordinates are stored in the internal memory. General pictures D, C and H are offset value. Top view Target Point (-) C Backsight Point Obstacle Reflector D (+) Offset Point Reflector Station Point Target Point (+) H Backsight Point Reflector Obstacle Reflector Offset Point Station Point 31 PSF Software Ver.365 7 OFFSET SHOTS Detailed Operating procedures 1. JOB NAME ( Selection keys: ⇐, ⇒, ⇑, ⇓ ) (1) JOB NAME input 1. JOB NAME ENT COORDINATE JOB NAME INPUT Screen JOB NAME input by pressing selection keys ENT P No ENT ENT STATION P. NUMBER LIST Screen ENT (2) JOB NAME selection ( Selection keys: ⇐, ⇒, ⇑, ⇓ ) 1 . JOB NAME ENT COORDINATE JOB NAME INPUT Screen Select the JOB NAME by shift keys ENT To the primary screen of OFFSET SHOTS The JOB NAME can be selected only when it is already stored. 2. STATION SETUP (1) STATION COORDINATES a. STATION COORDINATES input 2. STATION SETUP ENT ENT STATION P. NUMBER LIST Screen STATION COORDINATES INPUT Screen ENT 2. DESCRIPTION DESCRIPTION INPUT ENT X COORDINATE SELECT Input Y COORDINATE ENT Y COORDINATE SELECT Input Z COORDINATE ENT Z COORDINATE SELECT Input INSTR. H. P. No input SELECT ENT STORE BACKSIGHT SELECTION Screen ENT Maximum 4 digits can be inputted at STATION P. NUMBER. Please press the [STORE] key to store the input data. Maximum 8 letters can be inputted at the "DESCRIPTION". b. Search and call of the stored STATION COORDINATES 2. STATION SETUP ENT STATION P. NUMBER LIST Screen SELECT the NUMBER by shift keys INSTR. H. SELECT ENT Confirm the STATION COORDINATES values INPUT INSTR. H. BACKSIGHT SELECTION Screen 32 ENT PSF Software Ver.365 7 OFFSET SHOTS The INSTR. H, can be changed. (2) BACKSIGHT COORDINATES a. COORDINATES input BACKSIGHT COORDINATES input BACKSIGHT SELECTION Screen 1.COORDINATES INPUT BACKSIGHT P. NUMBER LIST Screen ENT BACKSIGHT COORDINATES INPUT Screen SELECT ENT P No input ENT 2. DESCRIPTION DESCRIPTION INPUT ENT X COORDINATE SELECT Input X COORDINATE ENT Y COORDINATE SELECT Input Y COORDINATE ENT Z COORDINATE SELECT Input Z COORDINATE ENT STORE Aim at the Backsight point ENT SURVEY ENT Maximum 4 digits can be inputted at the BACKSIGHT P. NUMBER. Please press the [STORE] key to store the input data. Search and call of the stored BACKSIGHT COORDINATES BACKSIGHT SELECTION Screen 1. COORDINATES INPUT BACKSIGHT P. NUMBER LIST Screen Select by shift keys Confirm the BACKSIGHT P. COORDINATES values After aiming at the Backsight point, push the ENT ENT b. AZIMUTH input 2 AZIMUTH INPUT Aim the Backsight Point AZIMUTH INPUT Press MEAS ENT Press F5 (1/2) Press F5 (2/2) SURVEY Screen 33 ENT ENT Shift keys: ( ∆, ∇, ⇑, ⇓ ) BACKSIGHT SELECTION ENT ENT Press H. INPUT SURVEY Screen PSF Software Ver.365 7 OFFSET SHOTS 3. SURVEY a. Offset point survey Place an Offset point at the place where the measurement from the Station point is possible. 3. SURVEY ENT PRISM H input ENT SURVEY Screen Press the F3 (PRISM H) Press MEAS (Measure the Offset point) Distance to the Offset P Is displayed. ENT OFFSET MEASURE Screen a. Target point survey OFFSET MEASURE Screen ENT 2. CROSS 3. HEIGHT SELECT 1. DISTANCE SELECT SELECT Value C Input Value H Input ENT Value D input ENT ENT OFFSET SHOTS Screen (Target point coordinates are displayed.) SURVEY Screen Value D,C and H are measured by using a tape measure. 34 STORE / ENT PSF Software Ver.365 8 REM General pictures of measurement With REM measurement, a prism (Reference point) is set approximately directly below the place to be measured, and by measuring the prism, the height to the target object can be measured. This makes it easy to determine the heights of electric power lines, bridge suspension cables, and other large items used in construction. General pictures Height Prism height Horizontal distance Prism Detailed Operating procedures Access the REM according to "1 . ACCESSING THE SPECIAL FUNCTIONS". Step 1 Observing the reference point (1) PRlSM H INPUT PRISM H ENT Input the height of the prism at the reference point ENT ENT Measure the distance to the reference point Go to Step 2 Step 2 Observing the target (1) Sight the target ENT (2) Press "ENT" to conclude the observation Display the height of the target Go back to Step 1 If necessary, repeat the measurement Press the "ESC" key to conclude the function 35 PSF Software Ver.365 9 RESECTION With RESECTION, two known points or three known points are measured in order to determine the coordinates of the Station Point. When the coordinates values of point A, B and C are stored in the internal memory, each coordinate input can be omitted by designating the each point number. General pictures Z Point A X Point B New Point Y Point C Detailed Operating procedures Access the RESECTION according to "ACCESSING THE SPECIAL FUNCTIONS". 1. JOB NAME (1) JOB NAME input 1. JOB NAME ENT ( Selection keys: ⇐, ⇒, ⇑, ⇓ ) COORDINATE JOB NAME INPUT Screen JOB NAME input by pressing selection keys ENT ENT STATION POINT INPUT Maximum 15 characters can be inputted at JOB NAME. (2) Stored JOB NAME selection 1. JOB NAME ENT ( Selection keys: ⇐, ⇒, ⇑, ⇓ ) COORDINATE JOB NAME INPUT Screen Select the stored JOB NAME by shift keys 36 ENT To the primary screen PSF Software Ver.365 9 RESECTION The JOB NAME can be selected only when it is already stored. 2. STATION SETUP 2. STATION SETUP STATION POINT INPUT STATION No, input ENT DESCRIPTION INPUT INSTR H Input 1. STATION No. 2. DESCRIPTION ENT ENT SELECT 3. INSTR. H. ENT SELECT SELECT To AP. NUMBER LIST Screen Maximum 8 letters can be inputted at the "DESCRIPTION". 3. SURVEY (1 ) 2 known points survey a. Known coordinates input Point A survey 3. SURVEY ENT AP. NUMBER LIST Screen A COORDINATES INPUT Screen 2. DESCRIPTION ENT SELECT P No input DESCRIPTION INRUT X SELECT X input ENT Y Z SELECT Z input ENT PRIZM H. Screen PRISM H. input ENT STORE / ENT Point A distance is displayed ENT SELECT Y input ENT ENT SELECT A SURVEY Screen MEAS B P. NUMBER LIST Screen Point B survey B P. NUMBER LIST Screen ENT B COORDINATES INPUT Screen ENT X P No input 2. DESCRIPTION SELECT X input Y SELECT Y input ENT Z SELECT Z input ENT PRISM H. Screen B SURVEY Screen SELECT MEAS ENT SELECT ENT PRISM H. PRISM H. Input ENT STORE/ ENT b. Search and call of the stored known coordinates Point A survey ENT SELECT Point B distance is displayed. Calculated Station Point coordinates are displayed. 3. SURVEY DESCRIPTION INPUT A P. NUMBER LIST Screen 37 STORE/ ENT ENT PSF Software Ver.365 9 Search and shift to desired P No ENT A PRISM HEIGHT INPUT Screen SELECT PRISM H. input MEAS ENT ENT Confirm point A coordinates A SURVEY Screen Point A distance is displayed RESECTION Aim at point A ENT B P. NUMBER LIST Screen Point B survey B P. NUMBER LIST Screen Search and shift to desired P No Confirm point B coordinates SELECT B PRISM HEIGHT INPUT Screen PRISM H. input Aim at point B ENT ENT MEAS ENT B SURVEY Screen Point B distance is displayed. Calculated Station Point coordinates are displayed. ENT STORE / ENT (2) 3 known points survey a) Known coordinates input Point A survey 3. SURVEY ENT A P. NUMBER LIST Screen A COORDINATES INPUT Screen ENT X SELECT ENT 2. DESCRIPTION SELECT Y input ENT PRISM H PRISM H. input X input Z ENT SELECT ENT P No input DESCRIPTION INPUT Y SELECT Z input SELECT ENT STORE / ENT Aim at the point A ENT Point B survey B P. NUMBER LIST Screen ENT B COORDINATES INPUT Screen P No input 2. DESCRIPTION ENT X SELECT X input ENT Y SELECT Y input Z SELECT PRISM H. input Z input ENT ENT ENT SELECT DESCRIPTION INPUT PRISM H. Screen SELECT ENT STORE / ENT Aim the point B Point C survey CP. NUMBER LIST Screen ENT P No input 38 ENT ENT PSF Software Ver.365 9 C COORDINATES INPUT Screen 2. DESCRIPTION ENT X SELECT X input ENT Y SELECT Y input Z SELECT PRISM H. input Z input SELECT DESCRIPTION INPUT PRISM H. Screen SELECT ENT ENT ENT RESECTION STORE / ENT Aim the point C Calculated station coordinates are displayed. ENT STORE / ENT The 3 known points survey does not require the distance measurement. b. Search and call of the stored known coordinates Point A survey 3. SURVEY ENT A P. NUMBER LIST Screen A PRISM HEIGHT Screen PRISM H. input Aim at point A PRISM H. ENT ENT Search and shift to desired P No SELECT A SURVEY Screen ENT Point B survey B P. NUMBER LIST Screen B PRISM HEIGHT Screen PRISM H. input Aim at point B Search and Shift to desired P No PRISM H. ENT ENT ENT SELECT B SURVEY Screen ENT Point C survey CP. NUMBER LIST Screen Search and shift to desired P No C PRISM HEIGHT INPUT Screen PRISM H. input Aim at point C ENT ENT PRIZM H. ENT SELECT C SURVEY Screen STATION POINT Screen Calculated Station coordinates are displayed. STORE / ENT The 3 known points survey does not require the distance measurement. 39 ENT PSF Software Ver.365 10 DATA STORAGE General pictures of measurement With Data storage, the data of the JOB NAME a STATION is stored in the internal memory or the instrument. General pictures Target Target Target Station Point Detailed Operating procedures Access the DATA STORAGE according to “ ACCESSING THE SPECIAL FUNCTIONS ". 1. JOB NAME (1 ) JOB NAME input ( Selection keys: ⇐, ⇒, ⇑, ⇓ ) 1 . JOB NAME ENT SURVEY JOB NAME INPUT JOB NAME input by pressing selection keys ENT ENT STATION POINT input Maximum 15 letters can be inputted at JOB NAME. (2 ) JOB NAME selection 1 . JOB NAME ENT ( Selection keys: ∆, ∇, ⇑, ⇓ ) SURVEY JOB NAME Select JOB NAME by shift keys ENT To the STATION POINT input The JOB NAME can be selected only when it is already stored. 40 PSF Software Ver.365 10 DATA STORAGE 2. STATION SETUP 2. STATION SETUP ENT STATION No. input STATION POINT INPUT ENT DESCRIPTION Input DESCRIPTION by Selection keys Input INSTR.H. ENT ENT STATION No. SELECT SELECT INSTR. H. SELECT STORE Maximum 4 digits can be inputted at STATION NUMBER. Please press the STORE key to store the input data. Maximum 15 letters can be inputted at the DESCRIPTION. 3. SURVEY 3. SURVEY ENT 1. POINT No. SELECT 2. DESCRIPTION 3. PRISM H. Press the POINT key SELECT SELECT Measure the P1 POINT No. input MEASURED POINT 1.POINT No. 2. DESCRIPTION 3.PRISM H ENT DESCRIPTION INPUT PRISM H. input ENT ENT ENT STORE / ENT Maximum 4 digits can be inputted at the POINT NUMBER. Please press the STORE key to store the measured data. The H. INPUT, O SET, HOLD of Horizontal angle is possible by pressing the F5 (2/2) key. Maximum 8 letters can be inputted at the "DESCRIPTION". 41 PSF Software Ver.365 11 MEMORY MANAGER With MEMORY MANAGER, following MEMORY MANAGEMENT of the instrument data can be performed. Coordinate data: SEND, RECEIVE, EDIT, DELETE Survey data: SEND, EDIT, DELETE Detailed Operating procedures Access the MEMORY MANAGER according to the "I . ACCESSING TO THE SPECIAL FUNCTIONS". 1. COORDINATES SEND : DC1, AUX and CSV data can be transferred. This function can send the stored Coordinates data into a personal computer etc. a. Send by input of the stored COORDINATES JOB NAME 1. COORDINATES SEND JOB NAME INPUT Screen ENT Select and Input a stored JOB NAME (The same job name Is found) ENT COORDINATES SEND Screen ENT 1. COMMUNICATION SET UP SELECT 1. BAUD RATE SELECT Shift to desired value ENT 2. DATA LENGTH SELECT Shift to desired value ENT 3. PARITY BITS SELECT Shift to desired article SELECT Shift to desired value SELECT Shift to ON/OFF ENT 6. XON/XOFF SELECT Shift to ON/OFF ENT ENT 2. FORMAT 3. COORD AXIS ENT SELECT SELECT ENT 4. STOP BITS ENT 5. SIGNAL CONTROL Shift to desired FORMAT ENT Shift to desired COORD AXIS ENT SEND CONFIRMATION Screen (JOB NAME---, After the push ENT key, Set the PC in com, mode) 42 ENT SEND PSF Software Ver.365 11 MEMORY MANAGER b. SEND by the search of stored COORDINATES JOB NAME 1. COORDINATES SEND ENT Shift to a desired JOB NAME COORDINATES SEND Screen JOB NAME INPUT Screen ENT ENT COMMUNICATION SET UP SELECT 1. BAUD RATE SELECT Shift to desired value ENT 2. DATA LENGTH SELECT Shift to desired value ENT 3. PARITY BITS SELECT Shift to desired article SELECT Shift to desired value SELECT Shift to ON/OFF ENT 6. XON/XOFF SELECT Shift to ON/OFF ENT ENT 2. FORMAT SELECT 3. COORD AXIS ENT ENT 4. STOP BITS ENT 5. SIGNAL CONTROL Shift to desired FORMAT SELECT ENT Shift to desired COORD AXIS ENT SEND CONFIRMATION Screen (JOB NAME---, After the push ENT key, Set the PC in com. mode) ENT SEND 2. COORDINATES RECEIVE : DC1, AUX and CSV data can be transferred. This function can receive the Coordinates data from a personal computer etc. 2. COORDINATES RECEIVE COORDINATES RECEIVE ENT 1. COMMUNICATION SETUP SELECT SELECT Shift to desired value ENT 2. DATA LENGTH SELECT Shift to desired value ENT 3. PARITY BITS SELECT Shift to desired article SELECT Shift to desired value SELECT Shift to ON/OFF ENT 6. XON/XOFF SELECT Shift to ON/OFF ENT ENT 2. FORMAT 3. COORD AXIS ENT SELECT SELECT ENT 4. STOP BITS ENT 5. SIGNAL CONTROL Shift to desired FORMAT ENT Shift to desired COORD AXIS RECEIVE CONFIRMATION Screen ( After the PC in com. Mode, push ENT key. ) 43 1. BAUD RATE ENT RECEIVE ENT PSF Software Ver.365 11 MEMORY MANAGER 3. COORDINATES EDIT This function can edit the stored Coordinates data. a. Edit by input & call of the COORDINATES JOB NAME and COORDINATES NUMBER 3. COORDINATES EDIT ENT JOB NAME INPUT Input the stored JOB NAME POINT NUMBER INPUT Input the P No ENT (The same job name is found) ENT ENT ENT COORDINATES EDIT ENT 2. DESCRIPTION SELECT DESCRIPTION INPUT X COORD. SELECT Input the X COORD ENT Y COORD. SELECT Input the Y COORD ENT Z COORD. SELECT Input the Z COORD ENT ENT (OVER WRITE) ENT b. Edit by search & shift of the COORDINATES JOB NAME and COORDINATES NUMBER 3. COORDINATES EDIT ENT JOB NAME INPUT Search and shift to the JOB NAME ENT Search & shift to the stored POINT NUMBER COORDINATES EDIT 2. DESCRIPTION ENT POINT NUMBER INPUT ENT SELECT DESCRIPTION INPUT X COORD. SELECT Input the X COORD ENT Y COORD. SELECT Input the Y COORD ENT Z COORD. SELECT Input the Z COORD ENT ENT (OVER WRITE) ENT 4. COORDINATES DELETE This function can delete the stored Coordinates data. a. Delete by input of the COORDINATES JOB NAME 4. COORDINATES DELETE Input the stored JOB NAME ENT JOB NAME INPUT Screen (The same job name is found) (JOB NAME---, Delete the job data. Are you sure ?) b. Delete by search of the COORDINATES JOB NAME 44 ENT ENT ENT ENT PSF Software Ver.365 11 4. COORDINATES DELETE ENT MEMORY MANAGER JOB NAME INPUT Screen Search & shift to stored JOB NAME ENT (JOB NAME---, Delete the job data. Are you sure ?) ENT 5. SURVEY DATA SEND : DC1, AUX and SDR data can be transferred. This function can send the stored Survey data into a personal computer etc. a. Send by input of the SURVEY JOB NAME 5. SURVEY DATA SEND ENT JOB NAME INPUT Screen ENT Select and Input a stored JOB NAME (The same job name is found) SURVEY DATA SEND Screen 1. COMMUNICATION SET UP SELECT SELECT Shift to desired value SELECT Shift to desired value SELECT Shift to desired article SELECT Shift to desired value SELECT Shift to ON/OFF ENT 6. XON/XOFF SELECT Shift to ON/OFF ENT ENT 2. FORMAT ENT SELECT ENT ENT ENT 1. BAUD RATE 2. DATA LENGTH 3. PARITY BITS ENT 4. STOP BITS ENT 5. SIGNAL CONTROL Shift to desired FORMAT ENT SEND CONFIRMATION Screen ( After the PC in com. Mode, push ENT key. ) ENT RECEIVE (JOB NAME---, After the push ENT key, Set the PC in com. mode) 45 ENT SEND PSF Software Ver.365 11 MEMORY MANAGER b. Send by search & call of the SURVEY JOB NAME 5. SURVEY DATA SEND ENT JOB NAME INPUT Screen Search a stored JOB NAME SURVEY DATA SEND Screen ENT 1. COOMUNICATION SET UP SELECT 1. BAUD RATE SELECT Shift to desired value ENT 2. DATA LENGTH SELECT Shift to desired value ENT 3. PARITY BITS SELECT Shift to desired article SELECT Shift to desired value SELECT Shift to ON/OFF ENT 6. XON/XOFF SELECT Shift to ON/OFF ENT ENT 2. FORMAT ENT SELECT ENT 4. STOP BITS ENT 5. SIGNAL CONTROL Shift to desired FORMAT ENT SEND CONFIRMATION Screen (JOB NAME---, After the push ENT key, Set the PC in com, mode) ENT SEND 6. SURVEY DATA EDIT This function can edit the stored Survey data. a. Edit by input & call of the SURVEY JOB NAME & SURVEY POINT NUMBER 6. SURVEY DATA EDIT ENT JOB NAME INPUT Input the stored JOB NAME (The same job name is found) POINT NUMBER INPUT Screen STATION (POINT) EDIT Screen 2. DESCRIPTION SELECT ENT Input the P No 1. STATION (POINT) No. SELECT Input ENT ENT Input ENT input ENT ENT ENT SELECT ENT 3. INST. (PRISM) HEIGHT (OVER WRITE) ENT b. Edit by search & call of the SURVEY JOB NAME & SURVEY POINT NUMBER 6. SURVEY DATA EDIT ENT JOB NAME INPUT Screen Search & shift to the stored JOB NAME ENT ENT Search & shift to the stored (STATION) POINT NUMBER INPUT Screen ENT STATION (POINT) EDIT Screen 1. STATION (POINT) No. 2. DESCRIPTION SELECT SELECT Input input 46 ENT ENT 3. INST. (PRISM) HEIGHT PSF Software Ver.365 11 SELECT Input ENT ENT (OVER WRITE) MEMORY MANAGER ENT 7. SURVEY DATA DELETE This function can delete the stored Survey data. a. Delete by input and call of the SURVEY JOB NAME 7. SURVEY DATA DELETE Input the stored JOB NAME ENT JOB NAME INPUT Screen (The same job name is found) (JOB NAME---, Delete the job data. Are you sure ?) ENT b. Delete by search and call of the SURVEY JOB NAME 7. SURVEY DATA DELETE ENT JOB NAME INPUT Screen Search & shift to stored JOB NAME ENT (JOB NAME---, Delete the job data. Are you sure ?) 47 ENT ENT ENT PSF Software Ver.365 12 DataLink DL- 01 Software DataLink DL01 Software allows you to send collected data by R-300 to other devices, to receive coordinates data, and to convert the resulting files into a number of common formats. a) Recommendation for "PN" It is recommended that "PN" (Point Name) data should consist of less or equal to 4 (one-byte) numeric characters to convert files with DL-01. Because, it may not be converted properly if alphabetic characters or more than 5 (one-byte) numeric characters are used for the "PN". b) Notes for the data transferring. Please, be careful about following items for the data transfer with "DL-01". b-1 Notes for unit. If you are requested to select unit when you convert data on DL-01, please select unit according to the settings on R-300. b-2 Limitation for each format. Please, use "CSV" or "DC1( DC-1Z) " format to transfer data to/from R-300. Limitation for the "CSV" format. With the "CSV" format, "PN" and "PC" (Point Code) data consist of less or equal to 8 (one-byte) characters can be transferred. Limitations for the "DC1 (DC-1Z)" format. With "DC1 (DC-1Z)" format, the length of "PN" data should consist of less or equal to 8 (one-byte) characters. And with the "DC1 (DC-1Z)" format "PC" data cannot be transferred. b-3 Recommended communication settings on R-300. Recommended settings for “COMMUNICAYTION SETUP” on R-300 special function is as follows. R-300BPC(DL-01) for “COORDINATES SEND” 1.BAUD RATE: 1200 2.DATA LENGTH: 8 3.PARITY BITS: NIL 4.STOP BITS: 1 5.SIGNAL CONTROL: OFF 6.XON/XOFF: OFF R-300BPC(DL-01) for “SURVEY DATA SEND” 1.BAUD RATE: 1200-9600 2.DATA LENGTH: 8 3.PARITY BITS: NIL 4.STOP BITS: 1 5.SIGNAL CONTROL: OFF 6.XON/XOFF: OFF PC(DL-01) R-300 for “COORDINATES RECEIVE” 1.BAUD RATE: 1200 2.DATA LENGTH: 8 3.PARITY BITS: NIL 4.STOP BITS: 1 5.SIGNAL CONTROL: OFF 48 PSF Software Ver.365 6.XON/XOFF: OFF Please note that these settings should be common with DL-01's. b-4 Recommended communication settings on DL-01 To configure DL-01 Communication setting, please read "Configuring the software" in the Help topics of DL-01. And select values as follows. For setting “Type of Device” in the "Settings" panel (Menu—“Edit”--”Settings”), select “PCS-300/R-100(PCS)/R-300(PSF)” for “R-300 PentaxSpecificationFunction” and other setting should be as follows. (Please note that these settings should be common with R-300's. And if the selection of “Type of Device” is not collect it may result in missing some data.) R-300BPC(DL-01) Bits per second: Databits: Parity: Stop bits: PC(DL-01)BR-300 Bits per second: Databits: Parity: Stop bits: 1200 8 None 1 (1200-9600 for sending "SURVEY DATA") 1200 8 None 1 c) Note for the Memory capacity Data transfer failure from DL01 to R-300 may cause reduction of memory capacity. If memory capacity becomes less, please back up required data first, and then initialize coordinates data. To initialize coordinates data, turn on the instrument while pressing [F2]+[F5]+[ON/OFF] keys, and take your finger off from [ON/OFF] again. After you see the message "COORD. DATA INITIAL", press [F5] key. Then the message "Please, wait" is displayed. When it is completed, the panel of Electronic Vial is displayed. 49 PSF Software Ver.365 d) Difference between “PowerTopoLite” CSV format on “PentaxSpecialFunction” and CSV file format from R-300 “PentaxSpecialFunction” version is slightly different from “PowerTopoLite” version as follows. Format Type of software version R-300 “PentaxSpecialFunction” PN,X,Y,Z,Code version PN,X,Y,Z,Code, R-300 “PowerTopoLite” version At the end of each line of CSV file output by “PowerTopoLite”, there is "," as shown above. e) Note on converting CSV file When you attempt to convert CSV file from R-300 by DL-01, please note that it may not succeed if CSV data type is not correct. After [CONVERT] button is clicked on DL-01 then “CSV files from PCS/R-100 (*.*)”is selected for the type of file,“CSV Import Option” will be appear. In the case of CSV data doesn't have “CODE” field, please select “PN XY” or “PN XYZ” from following four types for the “type” of data on the “CSV Import Option” panel. PN XY (Code) PN XYZ(Code) PN XY PN XYZ f) For more information to work with DL-01, please refer to the "help" file after the installation. 50 PSF Software Ver.365 PENTAX Industrial Instruments Co., Ltd. 2-5-2, Higashi-Oizumi, Nerima-ku, Tokyo, 178-0086, Japan Tel:+81-3-5905-1222 Fax:+81-3-5905-1225 CERTIFIED ISO 9001 & 14001 E-mail: [email protected] Member symbol of the Japan Surveying Instruments Manufacturers’ Association representing the high quality surveying products. 102002 51 First edition TS01101EB2 ">
/
ডাউনলোড
শুধু একটি বন্ধুত্বপূর্ণ অনুস্মারক। আপনি এখানে সরাসরি নথিটি দেখতে পারেন। তবে সবচেয়ে গুরুত্বপূর্ণ, আমাদের এআই ইতিমধ্যে এটি পড়েছে। এটি জটিল বিষয়গুলিকে সহজ শর্তে ব্যাখ্যা করতে পারে, যেকোনো ভাষায় আপনার প্রশ্নের উত্তর দিতে পারে এবং এমনকি দীর্ঘতম বা সবচেয়ে জটিল নথিগুলিকে দ্রুত নেভিগেট করতে আপনাকে সহায়তা করতে পারে।
বিজ্ঞাপন