Regulation rotative control
The regulation rotative control is used for the advanced management of dimmer
actuators and sound systems. The central pushbutton can be used to switch the
controlled dimmer ON and OFF, with times (soft-start and soft-stop) and switch-on
intensity (from 1 to 99%) that can be set by configuring the device. The rotary knob
instead accurately adjusts the controlled power from the minimum to the maximum
value
In the sound system it’s used to send to the BUS controls for the management of various
devices such as amplifiers and sound sources; the central pushbutton can be used for
“ON/OFF”, CD track, or saved radio station cycling control, while the knob can be used
to adjust the volume of the loudspeakers. The control may be configured as point-point,
room, and general.
1
2
Front view
Technical data
Power supply from BUS:
Operating power supply with SCS BUS:
Max. Absorption:
Operating temperature:
Size:
27 Vdc
18 – 27 Vdc
5 mA
5 – 35 °C
2 flush mounted modules
3
Configuration
A1
PL/PF
M
LIV1
LIV2
SPE
I
TECHNICAL SHEETS - AUTOMATION
Description
Rear view
A
PL/PF
M
LIV1
LIV2
SPE
I
ROOM
Light point/voice point
(Sound system)
mode
adjustment level 10 – 90
adjustment level 1 – 9
special
address of the device to be controlled
(see table 1 for details)
Legend
1. Knob
2. Pushbutton/LED
3. Configurator socket
1) Mode with SPE=0 - enhanced dimmer functions Can switch a dimmer actuator ON, selecting the level from 1% to 99%, and the soft-start and soft-stop speed. The times shown in the table refer to the maximum level.
The knob perform adjustment on 99 levels.
Possible function
Configurator in M
Configurator in LIV1
Configurator in LIV2 (unit)
(tens)
ON-OFF cyclic with selection of soft-start and soft-stop speed (see table 2).
1–9
0–9
0–9
If LIV1=LIV2=0 the load switches ON at the last level saved
ON-OFF cyclic with switching ON at the level from 1-99%. If LIV1=LIV2=0 the load 0–9
0–9
switches ON at the last level saved
Configurator in I
1–9
0
CEN
Address
Systems with logical extension. Address of interface
item F422 the BUS of which the dimmer to be driven
is found on
The dimmer is found in the same system as the control
Systems with logical extension. The dimmer is
found in the riser BUS and the knob control in one
of the connected systems
Table 2: start/stop time
Configurator in M
0
1
2
3
4
5
6
7
8
9
Time (sec.)
default
1
3
5
10
20
40
1 min.
2 min.
4 min. and 15 sec.
BT00066-b-UK
Table 1: address of the device to be controlled
1
HD4563 - HC4563 - HS4563
L4563 - N4563 - NT4563
2) Mode with SPE=1 - Sound system mode Possible function
Value configurator in M
Configurator in LIV1
Follow-me mode (*)
0
1 – 9 volume level when the amplifier is
activated, without configurators the last set level activates
Configurator in LIV2
Address of the first source to activate
1–4
1 – 9 volume level when the amplifier is
activated, without configurators the last set level activates
The A room can be configured from 1 to 9 for point-point function, or with AMB to identify a room, and finally with GEN for the activation of all the amplifiers of the house.
NOTE (*): the Follow-me mode allows to have the same music in another room after switching OFF the amplifier of the room previously occupied, and switching ON the one in the
current room.
3) Mode with SPE=2 - basic dimmer functions Can switch a dimmer ON, selecting the level from 1 to 9. If M = 0 the load switches ON at the last level saved. Unlike the mode with SPE=0 the knob can perform adjustments on 9 levels.
BT00066-b-UK
2
Possible function
Value configurator in M
Configurator in LIV1 (tens)
Configurator in LIV2 (unit)
Cyclical ON/OFF with switching ON at level 1 to 9
1–9
-
-