08-44.1 US MicroCal 200.CDR

08-44.1 US MicroCal 200.CDR
MicroCal 200/200+
MicroCal 2000+
Accurate and Reliable
365 Days a Year
MicroCal 200/200+
MicroCal 2000+
Table IN - OUT Range
Tc K
Tc T
Tc R
Tc S
Tc B
Tc C
Tc G
Tc D
Tc U
Tc L
Tc N
Tc E
Tc F
Pt100 IEC
OIML, a 3926
Pt100
a 3902
Pt100 JIS
SAMA
Pt 200
Pt 500
Pt1000 IEC
OIML
CU10
CU100
Ni100
Ni120
mV (L)
mV (H)
V
mA (In)
mA (Out)
W IN
W OUT
Frequency
Pulse counter
Pulse (Out)
-210
-350
-270
454
-270
-454
-50
-60
-50
-60
50
140
0
32
0
32
0
32
-200
-330
-200
-330
-270
-450
-270
-454
0
32
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
1200°C
2200°F
1370°C
2500°F
400°C
760°F
1760°C
3200°F
1760°C
3200°F
1820°C
3310°F
2300°C
4172°F
2300°C
4172°F
2300°C
4172°F
400°C
760°F
760°C
1400°F
1300°C
2380°F
1000°C
1840°F
1400°C
2560°F
-190
-310
-160
-256
-130
-238
150
302
170
338
920
1688
0
32
190
374
0
32
-160
-256
-200
-328
0
32
-200
-328
0
32
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
1200°C
2192°F
1260°C
2300°F
400°C
752°F
1760°C
3200°F
1760°C
3200°F
1820°C
3308°F
2000°C
3632°F
2300°C
4172°F
2130°C
3866°F
400°C
752°F
760°C
1400°F
1300°C
2372°F
1000°C
1832°F
1400°C
2552°F
0.1 °C
0.1 °F
0.1 °C
0.1 °F
0.01°C
0.1 °F
0.1 °C
0.1 °F
0.1 °C
0.1 °F
0.1 °C
0.1 °F
0.1 °C
0.1 °F
0.1 °C
0.1 °F
0.1 °C
0.1 °F
0.1 °C
0.1 °F
0.1 °C
0.1 °F
0.1 °C
0.1 °F
0.1 °C
0.1 °F
0.1 °C
0.1 °F
-200
-330
-200
-330
-200
-330
-200
-330
-200
-330
-200
-330
...
...
...
...
...
...
...
...
...
...
...
...
850°C
1570°F
650°C
1210°F
600°C
1120°F
850°C
1570°F
850°C
1570°F
850°C
1570°F
-200
-328
-200
-328
-200
-328
-200
-328
-200
-328
-200
-328
...
...
...
...
...
...
...
...
...
...
...
...
850°C
1562°F
650°C
1210°F
600°C
1112°F
850°C
1562°F
530°C
986°F
850°C
1562°F
0.01°C
0.1 °F
0.01°C
0.1 °F
0.01°C
0.1 °F
0.1 °C
0.1 °F
0.1 °C
0.1 °F
0.01°C
0.1 °F
±(0.02%
±(0.02%
±(0.02%
±(0.02%
±(0.02%
±(0.02%
±(0.02%
±(0.02%
±(0.02%
±(0.02%
±(0.02%
±(0.02%
+ 0.05°C)
+ 0.09°F)
+ 0.05°C)
+ 0.09°F)
+ 0.05°C)
+ 0.09°F)
+ 0.15°C)
+ 0.27°F)
+ 0.1 °C)
+ 0.18°F)
+ 0.1 °C)
+ 0.18°F)
± (0.01%
± (0.01%
± (0.01%
± (0.01%
± (0.01%
± (0.01%
± (0.01%
± (0.01%
± (0.01%
± (0.01%
± (0.01%
± (0.01%
+
+
+
+
+
+
+
+
+
+
+
+
0.05 °C)
0.09 °F)
0.05 °C)
0.09 °F)
0.05 °C)
0.09 °F)
0.15 °C)
0.27 °F)
0.1 °C)
0.18 °F)
0.1 °C)
0.18 °F)
0.01°C
0.1 °F
0.01°C
0.1 °F
0.01°C
0.1 °F
0.01°C
0.1 °F
0.01°C
0.1 °F
0.01°C
0.1 °F
±(0.005%
±(0.005%
±(0.005%
±(0.005%
±(0.005%
±(0.005%
±(0.005%
±(0.005%
±(0.005%
±(0.005%
±(0.005%
±(0.005%
+
+
+
+
+
+
+
+
+
+
+
+
0.05°C)
0.09°F)
0.05°C)
0.09°F)
0.05°C)
0.09°F)
0.15°C)
0.27°F)
0.1 °C)
0.18°F)
0.1 °C)
0.18°F)
-70
-100
-180
-300
-60
-80
0
32
...
...
...
...
...
...
...
...
150°C
310°F
150°C
310°F
180°C
360°F
150°C
310°F
-70
-94
-180
-292
-60
-76
0
32
...
...
...
...
...
...
...
...
150°C
302°F
150°C
302°F
180°C
356°F
150°C
302°F
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
±(0.02%
±(0.02%
±(0.02%
±(0.02%
±(0.02%
±(0.02%
±(0.02%
±(0.02%
+ 0.4 °C)
+ 0.72°F)
+ 0.05°C)
+ 0.09°F)
+ 0.05°C)
+ 0.09°F)
+ 0.05°C)
+ 0.09°F)
± (0.01%
± (0.01%
± (0.01%
± (0.01%
± (0.01%
± (0.01%
± (0.01%
± (0.01%
+
+
+
+
+
+
+
+
0.4 °C)
0.72 °F)
0.05 °C)
0.09 °F)
0.05 °C)
0.09 °F)
0.05 °C)
0.09 °F)
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
±(0.01%
±(0.01%
±(0.01%
±(0.01%
±(0.01%
±(0.01%
±(0.01%
±(0.01%
+
+
+
+
+
+
+
+
0.4 °C)
0.72°F)
0.05°C)
0.09°F)
0.05°C)
0.09°F)
0.05°C)
0.09°F)
-20
-0.2
-2
-5
0
0
0
0
0
1
1
1
0
0
0
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
Total range
Accuracy Range
+200mV
+2
V
+20 V
+50 mA
+50 mA
500 W
5000 W
500 W
5000 W
200 Hz
2000 Hz
20000 Hz
106 counts
6000 pulse/min
36000 pulse/h
Note:
• The MicroCal 200/200+ relative accuracies shown above are stated for
360 days and the operative conditions are from +64°F to +82°F
Resolution
°C
°F
°C
°F
°C
°F
°C
°F
1 mV
10 mV
0.1 mV
0.1 mA
0.1 mA
1 mW
0.01 W
1 mW
0.01 W
0.001 Hz
0.01
0.1 Hz
1 count
1 pulse/min
1 pulse/h
±(0.02% + 2 mV)
±(0.02% + 10 mV)
±(0.02% + 0.08mV)
±(0.02% + 0.4 mA)
±(0.02% + 0.4 mA)
±(0.02% + 12 mW)
±(0.02% +120 mW)
±(0.02% + 20 mW)
±(0.02% +200 mW)
±(0.005% + 0.001 Hz)
±(0.005% + 0.001 Hz)
±(0.005% + 0.001 Hz)
infinite
1 pulse / min
1 pulse / min
MicroCal 200+
Accuracy
(% of rdg)
± (0.01% + 0.1 °C)
± (0.01% + 0.18 °F)
± (0.01% + 0.1 °C)
± (0.01% + 0.18 °F)
± (0.01% + 0.1 °C)
± (0.01% + 0.18 °F)
± (0.01% + 0.2 °C)
± (0.01% + 0.36 °F)
± (0.01% + 0.2 °C)
± (0.01% + 0.36 °F)
± (0.01% + 0.3 °C)
± (0.01% + 0.54 °F)
± (0.01% + 0.2 °C)
± (0.01% + 0.36 °F)
± (0.01% + 0.3 °C)
± (0.01% + 0.54 °F)
± (0.01% + 0.3 °C)
± (0.01% + 0.54 °F)
± (0.01% + 0.1 °C)
± (0.01% + 0.18 °F)
± (0.01% + 0.1 °C)
± (0.01% + 0.18 °F)
± (0.01% + 0.1 °C)
± (0.01% + 0.18 °F)
± (0.01% + 0.1 °C)
± (0.01% + 0.18 °F)
± (0.01% + 0.1 °C)
± (0.01% + 0.18 °F)
MicroCal 2000+
Resolution
Accuracy
(% of rdg)
0.01°C
±(0.005% + 0.1 °C)
0.1 °F
±(0.005% + 0.18°F)
0.01°C
±(0.005% + 0.1 °C)
0.1 °F
±(0.005% + 0.18°F)
0.01°C
±(0.005% + 0.1 °C)
0.1 °F
±(0.005% + 0.18°F)
0.01°C
±(0.005% + 0.2 °C)
0.1 °F
±(0.005% + 0.36°F)
0.01°C
±(0.005% + 0.2 °C)
0.1 °F
±(0.005% + 0.36°F)
0.01°C
±(0.01% + 0.3 °C)
0.1 °F
±(0.01% + 0.54°F)
0.1 °C
±(0.01% + 0.2 °C)
0.1 °F
±(0.01% + 0.36 °F)
0.1 °C
±(0.01% + 0.3 °C)
0.1 °F
±(0.01% + 0.54 °F)
0.1 °C
±(0.01% + 0.3 °C)
0.1 °F
±(0.01% + 0.54 °F)
0.01°C
±(0.005% + 0.1 °C)
0.1 °F
±(0.005% + 0.18°F)
0.01°C
±(0.005% + 0.1 °C)
0.1 °F
±(0.005% + 0.18°F)
0.01°C
±(0.005% + 0.1 °C)
0.1 °F
±(0.005% + 0.18°F)
0.01°C
±(0.005% + 0.1 °C)
0.1 °F
±(0.005% + 0.18°F)
0.01°C
±(0.005% + 0.1 °C)
0.1 °F
±(0.005% + 0.18°F)
± (0.01% + 2 mV)
± (0.01% +10 mV)
± (0.01% + 0.08mV)
± (0.01% + 0.4 mA)
± (0.01% + 0.4 mA)
± (0.01% +12 mW)
± (0.01% +120 mW)
± (0.01% + 20 mW)
± (0.01% +200 mW)
±(0.005% + 0.001 Hz)
±(0.005% + 0.001 Hz)
±(0.005% + 0.001 Hz)
infinite
1 pulse / min
1 pulse / min
• The MicroCal 2000+ relative accuracies shown above are stated for 360
days and the operative conditions are from +70°F to +77°F
• Typical 90 days relative accuracy can be estimated by dividing the "% of
reading" specifications by 1.6.
°C
°F
°C
°F
°C
°F
°C
°F
0.1 mV
1 mV
10 mV
0.1 mA
0.1 mA
1 mW
0.01 W
1 mW
0.01 W
0.001 Hz
0.01 Hz
0.1 Hz
1 count
1 pulse / min
1 pulse / h
2-Channels High Accuracy Multifunctional Calibrators
Indisputably, One of
the Most Accurate
(±0.0035% rdg)
Portable Calibrators
Available Today !
±(0.0035% + 1 mV)
±(0.005% + 10 mV)
±(0.005% + 0.08mV)
±(0.005% + 0.4 mA)
±(0.005% + 0.4 mA)
±(0.005% + 12 mW)
±(0.005% +120 mW)
±(0.005% + 12 mW)
±(0.005% +120 mW)
±(0.005% + 0.001 Hz)
±(0.005% + 0.001 Hz)
±(0.005% + 0.001 Hz)
infinite
1 pulse / min
1 pulse / min
CalpMan Plus
Software for Automatic
Calibration and
Documenting in
Compliance with ISO9000
• Typical 2 years relative accuracy can be estimated by multiplying
the “% of reading" specifications by 1.4.
• All input ranges: additional error ±1 digit.
• E Instruments traceability chart and uncertainty can be supplied on
Distributed by:
Bulletin 08-44.1 US
Sensor or
parameter
Tc J
MicroCal 200
Accuracy
(% of rdg)
±(0.02% + 0.1 °C)
±(0.02% + 0.18°F)
±(0.02% + 0.1 °C)
±(0.02% + 0.18°F)
±(0.02% + 0.1 °C)
±(0.02% + 0.18°F)
±(0.02% + 0.2 °C)
±(0.02% + 0.36°F)
±(0.02% + 0.2 °C)
±(0.02% + 0.36°F)
±(0.02% + 0.3 °C)
±(0.02% + 0.54°F)
±(0.02% + 0.2 °C)
±(0.02% + 0.36°F)
±(0.02% + 0.3 °C)
±(0.02% + 0.54°F)
±(0.02% + 0.3 °C)
±(0.02% + 0.54°F)
±(0.02% + 0.1 °C)
±(0.02% + 0.18°F)
±(0.02% + 0.1 °C)
±(0.02% + 0.18°F)
±(0.02% + 0.1 °C)
±(0.02% + 0.18°F)
±(0.02% + 0.1 °C)
±(0.02% + 0.18°F)
±(0.02% + 0.1 °C)
±(0.02% + 0.18°F)
°C,°F, ,Hz
Tc,Rtd
mA,mV,V
MicroCal PM200
Module to Generate & to
Measure Pressure
All descriptions are related to a fully optioned instrument.
See last page for the different configurations.
MicroCal 200/200+
MicroCal 2000+
To Keep Your Test and Process Equipment
Accurately Calibrated for ISO 9000 Compliance
Performance
The MicroCal 200/200+ and MicroCal
2000+ are multifunctional calibrators
with insulated channels. The
instruments are portable and
developed to meet the needs of
instrumentation engineers and Quality
managers, both in laboratory and in
field work.
This units are accurate, rugged,
compact and easy to use. They are the
ideal solution to simulate and measure
simultaneously: Voltage, current,
resistance, thermocouple, resistance
thermometers, frequency and pulse.
Advanced flexibility and high
performance has been achieved using
a 32 bit microprocessor and a fast A/D
conversion technology. The calibrator’s
internal memory stores all data for
normalized IEC, DIN and JIS
thermoelectric sensors for both IPTS68
and ITS90 International Temperature
Scale. The microprocessor performs
automatic linearization and cold
junction compensation to assure high
accuracy. It is possible to set the
calibrator to execute menu-driven
calibration procedures for your
instruments in field work.
Both Channel 1 (Out) and Channel 2
(In) have the following operative mode
capabilities:
= millivolts
= volts
= milliamperes (active and passive
loop)
= Ohms
= temperature with thermocouples
= temperature with resistance
thermometers
= frequency
= pulse
MicroCal 200/200+
MicroCal 2000+
High Technology for Daily Use
On-Site and Laboratory
Specifications
IN/OUT parameters:
ways.
= Portable
Two different leather cases, with a
cover and shoulder strap, are
available upon request for
instrument alone or instrument,
printer and accessories. These are
extremely useful for practical use
since they leave one hand free for
instrument tuning.
=Panel mounting
It requires a panel cutout of 9.7” x
3.5”. The instrument bezel flange
butts against the front of the
mounting plate; two lateral mounting
brackets fit over the instrument rear
panel
= Table top
The case is equipped with 2 pivot
feet to change the vertical viewing
angle when using the instrument on
the top of a table.
Quality System
Research, development, production,
inspection and certification activities
are defined by methods and
procedures of the E Instruments
Quality System inspected for
compliance and certified ISO9001 by
GASTEC, a Dutch notified body.
Reference junction compensation:
Rj compensation drift:
Rj compensation error:
Common mode rejection:
Normal mode rejection:
Temperature stability:
Output impedance (emf output):
Input impedance (mV, V and Tc ranges):
Input impedance (mA ranges):
Source resistance effects:
Rtd and W simulation excitation current:
EMC Conformity
The instrument case, made in shockresistant injection moulded ABS +
polycarbonate has an internal metal
coating to fulfill the prevision of the
directive 89/336/CEE Electromagnetic
Compatibility.
Rtd and W measurement excitation current:
Rtd connection:
Rtd cable compensation:
Rtd cable compensation error (Pt100):
Maximum load resistance:
Display:
Measurement sampling time:
Output noise (at 300 Hz):
Digital interface:
Channel 1_Channel 2 insulation:
Calculation functions:
Selection °C/°F/K:
In/Out data memory:
Logging mode:
Convert function:
Scale factor:
Square root:
Calibration:
Power supply:
Self contained operation:
Remote auxiliary inputs are available
for:
= Relative humidity and
temperature module
= Two internal sensors and built-in
hand pump pressure module
Recharging time:
Line operation:
Line transformer insulation:
Firmware release identification:
Operating environment temperature range:
Storage temperature range:
Case:
Dimensions:
Weights:
The ergonomic case design allows the
user the calibrator in three different
Signal type:
thermocouples type:
resistance thermometers:
mV, V, mA, W, KW, frequency, pulses
J, K, T, R, S, B, N, C, E, U, L, F, G, D
Pt100 IEC, OIML, USLAB, US, SAMA, JIS, Pt200, 500,
1000, 1000 OIML, Ni100, Ni120, Cu10, Cu100
internal automatic:
from -10 °C to +55 °C (14°F to 130°F)
external adjustable:
from -50 °C to +100 °C (-58°F to 210°F)
remote with external Pt100: from -10°C to +100 °C (14°F to 210°F)
± 0.015°C/°C (from -10 °C to +55 °C)
internal :
±0.15°C (±0.3°F)
remote :
±0.3°C (±0.6°F)
>140 dB at ac operation
>70 dB at 50 or 60 Hz
MicroCal 200/200+: for temperature exceeding the band +18°C to +28°C (from +64 °C to +84 °F)
full scale:
± 8 ppm/°C
zero:
± 0.2 mV /°C
MicroCal 2000+: for temperature exceeding the band +21°C to +25°C (from +70 °C to +77 °F)
full scale:
± 3 ppm/°C
zero:
± 0.2 mV /°C
< 0.5 W with 0.5 mA maximum current
>10 MW
<140 W @ 1 mA
±1 mV error for 1000 W source resistance
MicroCal 200/200+:
from 0.01 to 5 mA
MicroCal 2000+:
from 0.01 to 2 mA
~ 0.4 mA @ 400W
~ 0.04 mA @ 4000W
2, 3, and 4 wires
up to 100 W (each wire)
±0.005°C/ W of total wire
1000 W @ 20 mA
graphic LCD 240 x 64 dots display with LED backlight device
250 ms
<2 mVpp for ranges up to 200 mV f.s.,
<10 mVpp for ranges up to 2 V f.s.
<80 mVpp for ranges up to 20 V f.s.
full bidirectional TTL (a RS232 adapter normal or insulated, is available as an option)
50 Vdc
hold, max, min, offset, average
through the configuration procedure
20 data with manual or automatic recall
1500 input data items (optional memory card for memory extension)
displays the electrical equivalent of the engineering unit
5 different settings with zero and span programmable within -399999 and +999999
in combination with scale factor
self learning technique with automatic procedure
external charger and rechargeable Ni-Cd battery
6h on Tc and mV input/output (backlight Off)
3.5h with 20 mA simulation (backlight Off)
5h at 90% and 6h at 99% with instrument switched off.
The battery charging is active only with the instrument switched off.
100 - 120 - 230 Vac through the external battery charger
2500 Vac
release code on the display
from -10 °C to +55 °C (from 14 °C to 130 °F)
from -30 °C to +60 °C (from -22 °C to 140 °F)
Injection moulded ABS with internal metal coating
264 x 96 x 172 mm (10.4”x3.8”x6.8”) DIN size
nett: 8.8 lb. gross: 12.1 lb.
Panel Mounting
7
MicroCal 200/200+
MicroCal 2000+
MicroCal 200/200+
MicroCal 2000+
Easy to Use
Easy to Order
INSTRUMENT HIGHLIGHTS
Ordering Code
CalpMan 2000 Software
Standard Agencies and Quality
Auditors require, to keep the
compliance with ISO 9000,
collection, organization and analysis
of traceable documents. CalpMan
2000 Windows® based supporting
software, is able to transfer a
selection of calibration routines from
a PC to the internal memory of the
instrument in order to simplify field
calibrations selecting the required
TAG number.
E Instruments CalpMan 2000 grants
the option to document the
calibration/inspection activities.
Cat. 39xx - A - B - C - D
cat. 3916
cat. 3918
cat. 3928
Microcal 200
Microcal 200+
Microcal 2000+
Each instrument is supplied with battery
charger, RS232 cable, PC software packages
(Logman, LinMan, and CalpMan) Report of
Calibration and Instruction Manual.
MicroCal
200
Comparative Table
Accuracy
0.02% rdg
MicroCal
200+
0.01% rdg
MicroCal
2000+
0.0035% rdg
32-bit microprocessor and flash memory for
firmware upgrading through serial interface
All normalized IEC, DIN, JIS thermocouples
Pt, Ni, Cu resistance thermometers
mA, mV, V, W, frequency, pulse, counter
IPTS 68 and ITS 90 linearization
Current output mode directly on active or passive loops
Table A
0
3
Options:
None
TTL/RS232 insulated converter
Table B
1
2
3
4
5
9
Line setting - Line cord plug
120 V 50/60Hz - USA plug
230 V 50/60Hz - Schuko plug
230 V 50/60Hz - UK plug
230 V 50/60Hz - European plug
100 V 50/60Hz - USA/Japan plug
special
Table C
0
1
4
5
6
Accessories
None
Leather case with shoulder strap (cat. BB880015) for instrument only
External impact printer
Leather case with shoulder strap (cat. BB880011) for instrument and printer
Brackets for panel mounting
Table D
1
9
Report of Calibration
E Instruments Report
Special
Bidirectional serial interface
Communication bus for extension to pressure and
other optional modules
Optional dedicated external impact type printer
Option
Option
Option
Pannel mounting brackets
Option
Option
Option
6 digits
6 digits
7 digits (0.1 mV)
Traceable Report of Calibration
RAM extension
with PCMCIA memory card
Non-volatile memory with real-time clock
Display & Keyboard
The large graphic display with back light
allows a simultaneous indication of the
measured and the simulated value
(large digit), together with all data
related to the signal as: engineering
unit, type of sensor or signal,
temperature scale, cold junction
selection, battery level, etc.
A swap key allow to change the position
of the IN and OUT parameters on the
display.
The operative set-up mode is simplified
by a sequence of menu pages that only
require <Select> and <Enter>
instructions.
A full set of instruction pages are
memory stored for direct operator
assistance.
The relevant instruction may be recalled
through the <Help> key.
Logging and direct real-time graph with movable cursor
to read the required actual value
mV and V I/O display
Real Time Graphic Logging
Digital interface
The instruments includes a full bidirectional TTL level digital interface for
communication with a computer.
A TTL/RS232 adaptor, normal or with
galvanic insulation, is available upon
request.
MicroCal 200/200+
MicroCal 2000+
CalpMan 2004
MicroCal PM200
3
MicroCal 200/200+
MicroCal 2000+
MicroCal 200/200+
MicroCal 2000+
mode or a direct numeric entry;
Firmware
The firmware is stored inside a flash
memory and allows a fast and easy
upgrade of the instrument using a
standard PC. Firmware includes the
following capabilities:
• multiple measurement and
generation mode
• signal processing: filter, average,
min, max
• PC downloadable test procedure
• DataLogger and graphic recorder
• switch test routine
• ramping and stepping for dynamic
testing
• user definable linearization
• user entry of probe specific
calibration coefficients.
Scale Factor - Square Root
All non-temperature ranges are fully
programmable to read both input
and output values in terms of
engineering units. Four
programmable alphanumeric
characters are available on the
display to show the symbol of the
parameter being measured
(i.e. mbar, % RH, % CO, etc.) The
unit allows the mA reading and
output to be related to flow when
using a DP transmitter across a
calibrated flange.
Rj Compensation
Accurate and fast response
compensation, through a special low
thermal capacity design of binding
posts, incorporates a thin film, high
accuracy Pt100 as cold junction
reference. The internal
reference allows
the maximum
accuracy for the
14 to 130°F
temperature
range. An
external Pt100
sensor can be
connected for
special application
(from 14 to +210°C).
It is possible
To Document the Inspection
and Calibration Activities
• direct keyboard access to n. 20
programmable memory stored
values;
Report of Calibration
Each MicroCal unit is factory
calibrated and certified against the
highest E Instruments Standards,
which are periodically certified by an
Internationally recognized laboratory
to ensure performance. The units are
also shipped with a Report of
Calibration stating the nominal and
actual values and the deviation
errors.
End
to manually set the compensation
temperature (from -58 to +210°F) by
keyboard.
Transmitter Simulation
The calibrator can be connected to
your system inputs to simulate 4-20
mA transmitters. It has an adequate
power to drive 20 mA into a load of
1000 W in source mode. For fast loop
checks, preprogrammed steps can
be recalled to output 4, 8, 12, 16 and
20 mA or % equivalent. Since the
instrument has two separate
channels. It is possible to read the
error directly in % (In/Out). The
operator can set and change
temperature values while obtaining
the equivalent output mA. The mA
mode may be connected directly
either on passive or on active current
loops.
Frequency - Counts
The "Out" mode is designed to
generate zero based square pulse,
with an adjustable amplitude, at a
frequency up to 20 KHz. A preset
4
number of pulses may be
programmed and transmitted to test or
to calibrate totalizers and counters.
The instrument can be configured to
measure frequency and count pulse
(totalizer mode). Technical units in Hz,
pulse/h and pulse/m. The threshold is
adjustable from 0 to 20 V with 0.01 V
resolution.
4 wire Resistance Thermometer
Although resistance and temperature
with resistance thermometer may be
measured with 2 or 3 wire standard
connections. The instrument is also
designed for 4-wire measurements
for higher accuracy and the ability to
use as a reference for your
calibrations.
Calculated Readings
The units allow measurements of
unstable input signals through a
programmable averaging or min, max
identification. A hold feature is also
included from a keyboard or external
contact instructions.
Remote Temperature Probe
A high accuracy probe is available
on request for general purpose
temperature measurement and/or
remote cold junction compensation.
Programmable Signal Converter
The instrument can be used as a
temporary signal converter
replacement. Any input signal
(including remote auxiliary inputs) can
be converted into any of the available
output signals. The galvanic insulation
between the input and output
channels allow to use this feature in
field work applications as well.
step
Start
Rise
Soack
Fall
Time
Pressure Module
An optional pressure module is
available with one or two internal
sensors. The MicroCal PM200 is an
intelligent module and it is used to
extend the MicroCal capability to
pressure in/out. Microcal Pm200 can
incorporate pressure/vacuum pump,
volume adjuster and ventilation
valve. External sensors can be used
to measure pressure up to 700bar.
See MicroCal PM200 bulletin for
more specifications.
Simulation Capability
Menu-driven set up to generate:
• a continuous or step ramp output
where the total time, the starting
point, the final point and the size of
the steps are requested by the setup procedure to run the program;
• a continuous programmable cycle
rises, soaks, falls; (see figure)
• the signal value setting uses a
unique in-line, single-digit setting
Temperature Modules
An optional set of temperature
calibrators are available for Tc and
Rtd certification. The MicroCal T
series can be used together with a
Personal Computer, a calibrator
MicroCal 200/200+, a scanner, and a
CalpMan Plus Windows® software
package to improve a true automatic
temperature calibration system.
5
Using the RS232 interfaces of the
instruments, it is possible, through a
PC, to program the complete test
procedure for your thermocouple or
resistance thermometer to be
certified. The MicroCal 200/200+ and
MicroCal 2000+ are able to read the
testing thermo-elements with the
desired accuracy and the software
calculate the errors and prepare the
certificate. See MicroCal T bulletin for
more specifications.
LogMan Software
Supporting software for DOS/
Windows to download any stored data
from internal memory to PC. Data can
be saved on disks, loaded from disks,
viewed in numeric or graphic mode
and also printed in numeric or graphic
mode.
LinMan Software
Supporting software for DOS/
Windows to setup the instrument with
Tcx, Rtdx special linearization. The
program allows highly accurate
temperature measurement with a
calibrated Pt100 loading the
coefficients of the Calibration Report.
CalpMan Software
Standard Agencies and Quality
Auditors require the collection,
organization and analysis of traceable
documents. A supporting software for
DOS/Windows (Calpman - Calibration
Procedure Manager) is available to
transfer a selection of calibration
routines (test points, error and
warning bands, etc.) from a PC to the
internal memory of the instrument in
order to automate field calibrations.
Select the appropriate tag number by
keyboard directly. The calibrator will
ask you step by step for all operation,
test, and calibration data ("before" and
"after" values), which can be stored in
the unit’s memory and down-loaded to
a PC to document the calibration
activity.