MicroCal 200/200+ MicroCal 2000+ Accurate and Reliable 365 Days a Year MicroCal 200/200+ MicroCal 2000+ Table IN - OUT Range Tc K Tc T Tc R Tc S Tc B Tc C Tc G Tc D Tc U Tc L Tc N Tc E Tc F Pt100 IEC OIML, a 3926 Pt100 a 3902 Pt100 JIS SAMA Pt 200 Pt 500 Pt1000 IEC OIML CU10 CU100 Ni100 Ni120 mV (L) mV (H) V mA (In) mA (Out) W IN W OUT Frequency Pulse counter Pulse (Out) -210 -350 -270 454 -270 -454 -50 -60 -50 -60 50 140 0 32 0 32 0 32 -200 -330 -200 -330 -270 -450 -270 -454 0 32 ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 1200°C 2200°F 1370°C 2500°F 400°C 760°F 1760°C 3200°F 1760°C 3200°F 1820°C 3310°F 2300°C 4172°F 2300°C 4172°F 2300°C 4172°F 400°C 760°F 760°C 1400°F 1300°C 2380°F 1000°C 1840°F 1400°C 2560°F -190 -310 -160 -256 -130 -238 150 302 170 338 920 1688 0 32 190 374 0 32 -160 -256 -200 -328 0 32 -200 -328 0 32 ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 1200°C 2192°F 1260°C 2300°F 400°C 752°F 1760°C 3200°F 1760°C 3200°F 1820°C 3308°F 2000°C 3632°F 2300°C 4172°F 2130°C 3866°F 400°C 752°F 760°C 1400°F 1300°C 2372°F 1000°C 1832°F 1400°C 2552°F 0.1 °C 0.1 °F 0.1 °C 0.1 °F 0.01°C 0.1 °F 0.1 °C 0.1 °F 0.1 °C 0.1 °F 0.1 °C 0.1 °F 0.1 °C 0.1 °F 0.1 °C 0.1 °F 0.1 °C 0.1 °F 0.1 °C 0.1 °F 0.1 °C 0.1 °F 0.1 °C 0.1 °F 0.1 °C 0.1 °F 0.1 °C 0.1 °F -200 -330 -200 -330 -200 -330 -200 -330 -200 -330 -200 -330 ... ... ... ... ... ... ... ... ... ... ... ... 850°C 1570°F 650°C 1210°F 600°C 1120°F 850°C 1570°F 850°C 1570°F 850°C 1570°F -200 -328 -200 -328 -200 -328 -200 -328 -200 -328 -200 -328 ... ... ... ... ... ... ... ... ... ... ... ... 850°C 1562°F 650°C 1210°F 600°C 1112°F 850°C 1562°F 530°C 986°F 850°C 1562°F 0.01°C 0.1 °F 0.01°C 0.1 °F 0.01°C 0.1 °F 0.1 °C 0.1 °F 0.1 °C 0.1 °F 0.01°C 0.1 °F ±(0.02% ±(0.02% ±(0.02% ±(0.02% ±(0.02% ±(0.02% ±(0.02% ±(0.02% ±(0.02% ±(0.02% ±(0.02% ±(0.02% + 0.05°C) + 0.09°F) + 0.05°C) + 0.09°F) + 0.05°C) + 0.09°F) + 0.15°C) + 0.27°F) + 0.1 °C) + 0.18°F) + 0.1 °C) + 0.18°F) ± (0.01% ± (0.01% ± (0.01% ± (0.01% ± (0.01% ± (0.01% ± (0.01% ± (0.01% ± (0.01% ± (0.01% ± (0.01% ± (0.01% + + + + + + + + + + + + 0.05 °C) 0.09 °F) 0.05 °C) 0.09 °F) 0.05 °C) 0.09 °F) 0.15 °C) 0.27 °F) 0.1 °C) 0.18 °F) 0.1 °C) 0.18 °F) 0.01°C 0.1 °F 0.01°C 0.1 °F 0.01°C 0.1 °F 0.01°C 0.1 °F 0.01°C 0.1 °F 0.01°C 0.1 °F ±(0.005% ±(0.005% ±(0.005% ±(0.005% ±(0.005% ±(0.005% ±(0.005% ±(0.005% ±(0.005% ±(0.005% ±(0.005% ±(0.005% + + + + + + + + + + + + 0.05°C) 0.09°F) 0.05°C) 0.09°F) 0.05°C) 0.09°F) 0.15°C) 0.27°F) 0.1 °C) 0.18°F) 0.1 °C) 0.18°F) -70 -100 -180 -300 -60 -80 0 32 ... ... ... ... ... ... ... ... 150°C 310°F 150°C 310°F 180°C 360°F 150°C 310°F -70 -94 -180 -292 -60 -76 0 32 ... ... ... ... ... ... ... ... 150°C 302°F 150°C 302°F 180°C 356°F 150°C 302°F 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 ±(0.02% ±(0.02% ±(0.02% ±(0.02% ±(0.02% ±(0.02% ±(0.02% ±(0.02% + 0.4 °C) + 0.72°F) + 0.05°C) + 0.09°F) + 0.05°C) + 0.09°F) + 0.05°C) + 0.09°F) ± (0.01% ± (0.01% ± (0.01% ± (0.01% ± (0.01% ± (0.01% ± (0.01% ± (0.01% + + + + + + + + 0.4 °C) 0.72 °F) 0.05 °C) 0.09 °F) 0.05 °C) 0.09 °F) 0.05 °C) 0.09 °F) 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 ±(0.01% ±(0.01% ±(0.01% ±(0.01% ±(0.01% ±(0.01% ±(0.01% ±(0.01% + + + + + + + + 0.4 °C) 0.72°F) 0.05°C) 0.09°F) 0.05°C) 0.09°F) 0.05°C) 0.09°F) -20 -0.2 -2 -5 0 0 0 0 0 1 1 1 0 0 0 ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... Total range Accuracy Range +200mV +2 V +20 V +50 mA +50 mA 500 W 5000 W 500 W 5000 W 200 Hz 2000 Hz 20000 Hz 106 counts 6000 pulse/min 36000 pulse/h Note: • The MicroCal 200/200+ relative accuracies shown above are stated for 360 days and the operative conditions are from +64°F to +82°F Resolution °C °F °C °F °C °F °C °F 1 mV 10 mV 0.1 mV 0.1 mA 0.1 mA 1 mW 0.01 W 1 mW 0.01 W 0.001 Hz 0.01 0.1 Hz 1 count 1 pulse/min 1 pulse/h ±(0.02% + 2 mV) ±(0.02% + 10 mV) ±(0.02% + 0.08mV) ±(0.02% + 0.4 mA) ±(0.02% + 0.4 mA) ±(0.02% + 12 mW) ±(0.02% +120 mW) ±(0.02% + 20 mW) ±(0.02% +200 mW) ±(0.005% + 0.001 Hz) ±(0.005% + 0.001 Hz) ±(0.005% + 0.001 Hz) infinite 1 pulse / min 1 pulse / min MicroCal 200+ Accuracy (% of rdg) ± (0.01% + 0.1 °C) ± (0.01% + 0.18 °F) ± (0.01% + 0.1 °C) ± (0.01% + 0.18 °F) ± (0.01% + 0.1 °C) ± (0.01% + 0.18 °F) ± (0.01% + 0.2 °C) ± (0.01% + 0.36 °F) ± (0.01% + 0.2 °C) ± (0.01% + 0.36 °F) ± (0.01% + 0.3 °C) ± (0.01% + 0.54 °F) ± (0.01% + 0.2 °C) ± (0.01% + 0.36 °F) ± (0.01% + 0.3 °C) ± (0.01% + 0.54 °F) ± (0.01% + 0.3 °C) ± (0.01% + 0.54 °F) ± (0.01% + 0.1 °C) ± (0.01% + 0.18 °F) ± (0.01% + 0.1 °C) ± (0.01% + 0.18 °F) ± (0.01% + 0.1 °C) ± (0.01% + 0.18 °F) ± (0.01% + 0.1 °C) ± (0.01% + 0.18 °F) ± (0.01% + 0.1 °C) ± (0.01% + 0.18 °F) MicroCal 2000+ Resolution Accuracy (% of rdg) 0.01°C ±(0.005% + 0.1 °C) 0.1 °F ±(0.005% + 0.18°F) 0.01°C ±(0.005% + 0.1 °C) 0.1 °F ±(0.005% + 0.18°F) 0.01°C ±(0.005% + 0.1 °C) 0.1 °F ±(0.005% + 0.18°F) 0.01°C ±(0.005% + 0.2 °C) 0.1 °F ±(0.005% + 0.36°F) 0.01°C ±(0.005% + 0.2 °C) 0.1 °F ±(0.005% + 0.36°F) 0.01°C ±(0.01% + 0.3 °C) 0.1 °F ±(0.01% + 0.54°F) 0.1 °C ±(0.01% + 0.2 °C) 0.1 °F ±(0.01% + 0.36 °F) 0.1 °C ±(0.01% + 0.3 °C) 0.1 °F ±(0.01% + 0.54 °F) 0.1 °C ±(0.01% + 0.3 °C) 0.1 °F ±(0.01% + 0.54 °F) 0.01°C ±(0.005% + 0.1 °C) 0.1 °F ±(0.005% + 0.18°F) 0.01°C ±(0.005% + 0.1 °C) 0.1 °F ±(0.005% + 0.18°F) 0.01°C ±(0.005% + 0.1 °C) 0.1 °F ±(0.005% + 0.18°F) 0.01°C ±(0.005% + 0.1 °C) 0.1 °F ±(0.005% + 0.18°F) 0.01°C ±(0.005% + 0.1 °C) 0.1 °F ±(0.005% + 0.18°F) ± (0.01% + 2 mV) ± (0.01% +10 mV) ± (0.01% + 0.08mV) ± (0.01% + 0.4 mA) ± (0.01% + 0.4 mA) ± (0.01% +12 mW) ± (0.01% +120 mW) ± (0.01% + 20 mW) ± (0.01% +200 mW) ±(0.005% + 0.001 Hz) ±(0.005% + 0.001 Hz) ±(0.005% + 0.001 Hz) infinite 1 pulse / min 1 pulse / min • The MicroCal 2000+ relative accuracies shown above are stated for 360 days and the operative conditions are from +70°F to +77°F • Typical 90 days relative accuracy can be estimated by dividing the "% of reading" specifications by 1.6. °C °F °C °F °C °F °C °F 0.1 mV 1 mV 10 mV 0.1 mA 0.1 mA 1 mW 0.01 W 1 mW 0.01 W 0.001 Hz 0.01 Hz 0.1 Hz 1 count 1 pulse / min 1 pulse / h 2-Channels High Accuracy Multifunctional Calibrators Indisputably, One of the Most Accurate (±0.0035% rdg) Portable Calibrators Available Today ! ±(0.0035% + 1 mV) ±(0.005% + 10 mV) ±(0.005% + 0.08mV) ±(0.005% + 0.4 mA) ±(0.005% + 0.4 mA) ±(0.005% + 12 mW) ±(0.005% +120 mW) ±(0.005% + 12 mW) ±(0.005% +120 mW) ±(0.005% + 0.001 Hz) ±(0.005% + 0.001 Hz) ±(0.005% + 0.001 Hz) infinite 1 pulse / min 1 pulse / min CalpMan Plus Software for Automatic Calibration and Documenting in Compliance with ISO9000 • Typical 2 years relative accuracy can be estimated by multiplying the “% of reading" specifications by 1.4. • All input ranges: additional error ±1 digit. • E Instruments traceability chart and uncertainty can be supplied on Distributed by: Bulletin 08-44.1 US Sensor or parameter Tc J MicroCal 200 Accuracy (% of rdg) ±(0.02% + 0.1 °C) ±(0.02% + 0.18°F) ±(0.02% + 0.1 °C) ±(0.02% + 0.18°F) ±(0.02% + 0.1 °C) ±(0.02% + 0.18°F) ±(0.02% + 0.2 °C) ±(0.02% + 0.36°F) ±(0.02% + 0.2 °C) ±(0.02% + 0.36°F) ±(0.02% + 0.3 °C) ±(0.02% + 0.54°F) ±(0.02% + 0.2 °C) ±(0.02% + 0.36°F) ±(0.02% + 0.3 °C) ±(0.02% + 0.54°F) ±(0.02% + 0.3 °C) ±(0.02% + 0.54°F) ±(0.02% + 0.1 °C) ±(0.02% + 0.18°F) ±(0.02% + 0.1 °C) ±(0.02% + 0.18°F) ±(0.02% + 0.1 °C) ±(0.02% + 0.18°F) ±(0.02% + 0.1 °C) ±(0.02% + 0.18°F) ±(0.02% + 0.1 °C) ±(0.02% + 0.18°F) °C,°F, ,Hz Tc,Rtd mA,mV,V MicroCal PM200 Module to Generate & to Measure Pressure All descriptions are related to a fully optioned instrument. See last page for the different configurations. MicroCal 200/200+ MicroCal 2000+ To Keep Your Test and Process Equipment Accurately Calibrated for ISO 9000 Compliance Performance The MicroCal 200/200+ and MicroCal 2000+ are multifunctional calibrators with insulated channels. The instruments are portable and developed to meet the needs of instrumentation engineers and Quality managers, both in laboratory and in field work. This units are accurate, rugged, compact and easy to use. They are the ideal solution to simulate and measure simultaneously: Voltage, current, resistance, thermocouple, resistance thermometers, frequency and pulse. Advanced flexibility and high performance has been achieved using a 32 bit microprocessor and a fast A/D conversion technology. The calibrator’s internal memory stores all data for normalized IEC, DIN and JIS thermoelectric sensors for both IPTS68 and ITS90 International Temperature Scale. The microprocessor performs automatic linearization and cold junction compensation to assure high accuracy. It is possible to set the calibrator to execute menu-driven calibration procedures for your instruments in field work. Both Channel 1 (Out) and Channel 2 (In) have the following operative mode capabilities: = millivolts = volts = milliamperes (active and passive loop) = Ohms = temperature with thermocouples = temperature with resistance thermometers = frequency = pulse MicroCal 200/200+ MicroCal 2000+ High Technology for Daily Use On-Site and Laboratory Specifications IN/OUT parameters: ways. = Portable Two different leather cases, with a cover and shoulder strap, are available upon request for instrument alone or instrument, printer and accessories. These are extremely useful for practical use since they leave one hand free for instrument tuning. =Panel mounting It requires a panel cutout of 9.7” x 3.5”. The instrument bezel flange butts against the front of the mounting plate; two lateral mounting brackets fit over the instrument rear panel = Table top The case is equipped with 2 pivot feet to change the vertical viewing angle when using the instrument on the top of a table. Quality System Research, development, production, inspection and certification activities are defined by methods and procedures of the E Instruments Quality System inspected for compliance and certified ISO9001 by GASTEC, a Dutch notified body. Reference junction compensation: Rj compensation drift: Rj compensation error: Common mode rejection: Normal mode rejection: Temperature stability: Output impedance (emf output): Input impedance (mV, V and Tc ranges): Input impedance (mA ranges): Source resistance effects: Rtd and W simulation excitation current: EMC Conformity The instrument case, made in shockresistant injection moulded ABS + polycarbonate has an internal metal coating to fulfill the prevision of the directive 89/336/CEE Electromagnetic Compatibility. Rtd and W measurement excitation current: Rtd connection: Rtd cable compensation: Rtd cable compensation error (Pt100): Maximum load resistance: Display: Measurement sampling time: Output noise (at 300 Hz): Digital interface: Channel 1_Channel 2 insulation: Calculation functions: Selection °C/°F/K: In/Out data memory: Logging mode: Convert function: Scale factor: Square root: Calibration: Power supply: Self contained operation: Remote auxiliary inputs are available for: = Relative humidity and temperature module = Two internal sensors and built-in hand pump pressure module Recharging time: Line operation: Line transformer insulation: Firmware release identification: Operating environment temperature range: Storage temperature range: Case: Dimensions: Weights: The ergonomic case design allows the user the calibrator in three different Signal type: thermocouples type: resistance thermometers: mV, V, mA, W, KW, frequency, pulses J, K, T, R, S, B, N, C, E, U, L, F, G, D Pt100 IEC, OIML, USLAB, US, SAMA, JIS, Pt200, 500, 1000, 1000 OIML, Ni100, Ni120, Cu10, Cu100 internal automatic: from -10 °C to +55 °C (14°F to 130°F) external adjustable: from -50 °C to +100 °C (-58°F to 210°F) remote with external Pt100: from -10°C to +100 °C (14°F to 210°F) ± 0.015°C/°C (from -10 °C to +55 °C) internal : ±0.15°C (±0.3°F) remote : ±0.3°C (±0.6°F) >140 dB at ac operation >70 dB at 50 or 60 Hz MicroCal 200/200+: for temperature exceeding the band +18°C to +28°C (from +64 °C to +84 °F) full scale: ± 8 ppm/°C zero: ± 0.2 mV /°C MicroCal 2000+: for temperature exceeding the band +21°C to +25°C (from +70 °C to +77 °F) full scale: ± 3 ppm/°C zero: ± 0.2 mV /°C < 0.5 W with 0.5 mA maximum current >10 MW <140 W @ 1 mA ±1 mV error for 1000 W source resistance MicroCal 200/200+: from 0.01 to 5 mA MicroCal 2000+: from 0.01 to 2 mA ~ 0.4 mA @ 400W ~ 0.04 mA @ 4000W 2, 3, and 4 wires up to 100 W (each wire) ±0.005°C/ W of total wire 1000 W @ 20 mA graphic LCD 240 x 64 dots display with LED backlight device 250 ms <2 mVpp for ranges up to 200 mV f.s., <10 mVpp for ranges up to 2 V f.s. <80 mVpp for ranges up to 20 V f.s. full bidirectional TTL (a RS232 adapter normal or insulated, is available as an option) 50 Vdc hold, max, min, offset, average through the configuration procedure 20 data with manual or automatic recall 1500 input data items (optional memory card for memory extension) displays the electrical equivalent of the engineering unit 5 different settings with zero and span programmable within -399999 and +999999 in combination with scale factor self learning technique with automatic procedure external charger and rechargeable Ni-Cd battery 6h on Tc and mV input/output (backlight Off) 3.5h with 20 mA simulation (backlight Off) 5h at 90% and 6h at 99% with instrument switched off. The battery charging is active only with the instrument switched off. 100 - 120 - 230 Vac through the external battery charger 2500 Vac release code on the display from -10 °C to +55 °C (from 14 °C to 130 °F) from -30 °C to +60 °C (from -22 °C to 140 °F) Injection moulded ABS with internal metal coating 264 x 96 x 172 mm (10.4”x3.8”x6.8”) DIN size nett: 8.8 lb. gross: 12.1 lb. Panel Mounting 7 MicroCal 200/200+ MicroCal 2000+ MicroCal 200/200+ MicroCal 2000+ Easy to Use Easy to Order INSTRUMENT HIGHLIGHTS Ordering Code CalpMan 2000 Software Standard Agencies and Quality Auditors require, to keep the compliance with ISO 9000, collection, organization and analysis of traceable documents. CalpMan 2000 Windows® based supporting software, is able to transfer a selection of calibration routines from a PC to the internal memory of the instrument in order to simplify field calibrations selecting the required TAG number. E Instruments CalpMan 2000 grants the option to document the calibration/inspection activities. Cat. 39xx - A - B - C - D cat. 3916 cat. 3918 cat. 3928 Microcal 200 Microcal 200+ Microcal 2000+ Each instrument is supplied with battery charger, RS232 cable, PC software packages (Logman, LinMan, and CalpMan) Report of Calibration and Instruction Manual. MicroCal 200 Comparative Table Accuracy 0.02% rdg MicroCal 200+ 0.01% rdg MicroCal 2000+ 0.0035% rdg 32-bit microprocessor and flash memory for firmware upgrading through serial interface All normalized IEC, DIN, JIS thermocouples Pt, Ni, Cu resistance thermometers mA, mV, V, W, frequency, pulse, counter IPTS 68 and ITS 90 linearization Current output mode directly on active or passive loops Table A 0 3 Options: None TTL/RS232 insulated converter Table B 1 2 3 4 5 9 Line setting - Line cord plug 120 V 50/60Hz - USA plug 230 V 50/60Hz - Schuko plug 230 V 50/60Hz - UK plug 230 V 50/60Hz - European plug 100 V 50/60Hz - USA/Japan plug special Table C 0 1 4 5 6 Accessories None Leather case with shoulder strap (cat. BB880015) for instrument only External impact printer Leather case with shoulder strap (cat. BB880011) for instrument and printer Brackets for panel mounting Table D 1 9 Report of Calibration E Instruments Report Special Bidirectional serial interface Communication bus for extension to pressure and other optional modules Optional dedicated external impact type printer Option Option Option Pannel mounting brackets Option Option Option 6 digits 6 digits 7 digits (0.1 mV) Traceable Report of Calibration RAM extension with PCMCIA memory card Non-volatile memory with real-time clock Display & Keyboard The large graphic display with back light allows a simultaneous indication of the measured and the simulated value (large digit), together with all data related to the signal as: engineering unit, type of sensor or signal, temperature scale, cold junction selection, battery level, etc. A swap key allow to change the position of the IN and OUT parameters on the display. The operative set-up mode is simplified by a sequence of menu pages that only require <Select> and <Enter> instructions. A full set of instruction pages are memory stored for direct operator assistance. The relevant instruction may be recalled through the <Help> key. Logging and direct real-time graph with movable cursor to read the required actual value mV and V I/O display Real Time Graphic Logging Digital interface The instruments includes a full bidirectional TTL level digital interface for communication with a computer. A TTL/RS232 adaptor, normal or with galvanic insulation, is available upon request. MicroCal 200/200+ MicroCal 2000+ CalpMan 2004 MicroCal PM200 3 MicroCal 200/200+ MicroCal 2000+ MicroCal 200/200+ MicroCal 2000+ mode or a direct numeric entry; Firmware The firmware is stored inside a flash memory and allows a fast and easy upgrade of the instrument using a standard PC. Firmware includes the following capabilities: • multiple measurement and generation mode • signal processing: filter, average, min, max • PC downloadable test procedure • DataLogger and graphic recorder • switch test routine • ramping and stepping for dynamic testing • user definable linearization • user entry of probe specific calibration coefficients. Scale Factor - Square Root All non-temperature ranges are fully programmable to read both input and output values in terms of engineering units. Four programmable alphanumeric characters are available on the display to show the symbol of the parameter being measured (i.e. mbar, % RH, % CO, etc.) The unit allows the mA reading and output to be related to flow when using a DP transmitter across a calibrated flange. Rj Compensation Accurate and fast response compensation, through a special low thermal capacity design of binding posts, incorporates a thin film, high accuracy Pt100 as cold junction reference. The internal reference allows the maximum accuracy for the 14 to 130°F temperature range. An external Pt100 sensor can be connected for special application (from 14 to +210°C). It is possible To Document the Inspection and Calibration Activities • direct keyboard access to n. 20 programmable memory stored values; Report of Calibration Each MicroCal unit is factory calibrated and certified against the highest E Instruments Standards, which are periodically certified by an Internationally recognized laboratory to ensure performance. The units are also shipped with a Report of Calibration stating the nominal and actual values and the deviation errors. End to manually set the compensation temperature (from -58 to +210°F) by keyboard. Transmitter Simulation The calibrator can be connected to your system inputs to simulate 4-20 mA transmitters. It has an adequate power to drive 20 mA into a load of 1000 W in source mode. For fast loop checks, preprogrammed steps can be recalled to output 4, 8, 12, 16 and 20 mA or % equivalent. Since the instrument has two separate channels. It is possible to read the error directly in % (In/Out). The operator can set and change temperature values while obtaining the equivalent output mA. The mA mode may be connected directly either on passive or on active current loops. Frequency - Counts The "Out" mode is designed to generate zero based square pulse, with an adjustable amplitude, at a frequency up to 20 KHz. A preset 4 number of pulses may be programmed and transmitted to test or to calibrate totalizers and counters. The instrument can be configured to measure frequency and count pulse (totalizer mode). Technical units in Hz, pulse/h and pulse/m. The threshold is adjustable from 0 to 20 V with 0.01 V resolution. 4 wire Resistance Thermometer Although resistance and temperature with resistance thermometer may be measured with 2 or 3 wire standard connections. The instrument is also designed for 4-wire measurements for higher accuracy and the ability to use as a reference for your calibrations. Calculated Readings The units allow measurements of unstable input signals through a programmable averaging or min, max identification. A hold feature is also included from a keyboard or external contact instructions. Remote Temperature Probe A high accuracy probe is available on request for general purpose temperature measurement and/or remote cold junction compensation. Programmable Signal Converter The instrument can be used as a temporary signal converter replacement. Any input signal (including remote auxiliary inputs) can be converted into any of the available output signals. The galvanic insulation between the input and output channels allow to use this feature in field work applications as well. step Start Rise Soack Fall Time Pressure Module An optional pressure module is available with one or two internal sensors. The MicroCal PM200 is an intelligent module and it is used to extend the MicroCal capability to pressure in/out. Microcal Pm200 can incorporate pressure/vacuum pump, volume adjuster and ventilation valve. External sensors can be used to measure pressure up to 700bar. See MicroCal PM200 bulletin for more specifications. Simulation Capability Menu-driven set up to generate: • a continuous or step ramp output where the total time, the starting point, the final point and the size of the steps are requested by the setup procedure to run the program; • a continuous programmable cycle rises, soaks, falls; (see figure) • the signal value setting uses a unique in-line, single-digit setting Temperature Modules An optional set of temperature calibrators are available for Tc and Rtd certification. The MicroCal T series can be used together with a Personal Computer, a calibrator MicroCal 200/200+, a scanner, and a CalpMan Plus Windows® software package to improve a true automatic temperature calibration system. 5 Using the RS232 interfaces of the instruments, it is possible, through a PC, to program the complete test procedure for your thermocouple or resistance thermometer to be certified. The MicroCal 200/200+ and MicroCal 2000+ are able to read the testing thermo-elements with the desired accuracy and the software calculate the errors and prepare the certificate. See MicroCal T bulletin for more specifications. LogMan Software Supporting software for DOS/ Windows to download any stored data from internal memory to PC. Data can be saved on disks, loaded from disks, viewed in numeric or graphic mode and also printed in numeric or graphic mode. LinMan Software Supporting software for DOS/ Windows to setup the instrument with Tcx, Rtdx special linearization. The program allows highly accurate temperature measurement with a calibrated Pt100 loading the coefficients of the Calibration Report. CalpMan Software Standard Agencies and Quality Auditors require the collection, organization and analysis of traceable documents. A supporting software for DOS/Windows (Calpman - Calibration Procedure Manager) is available to transfer a selection of calibration routines (test points, error and warning bands, etc.) from a PC to the internal memory of the instrument in order to automate field calibrations. Select the appropriate tag number by keyboard directly. The calibrator will ask you step by step for all operation, test, and calibration data ("before" and "after" values), which can be stored in the unit’s memory and down-loaded to a PC to document the calibration activity.
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement