null  null
A New House for
Alpha Phi Sorority
Georgia Tech University
Atlanta, Georgia
Issued for Contract: 03/11/2014
Addendum 1: 03/28/2014
Addendum 2: 07/25/2014
Addendum 3: 09/05/2014
Reissued for Pricing: 01/22/2016
H u g a n d A s s o c i a t e s, A r c h i t e c t s
Architecture • Interior Design
5250 Avalon Boulevard
Alpharetta, Georgia 30009
678-297-2929
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 2 of 41
January 22, 2016
Bidding and Contract Requirements
00 72 00
General Conditions
Claims, disputes or other matters in question that are not specifically addressed by the Owner's
Contract with the Contractor or these documents shall be governed by the Standard Form of
Agreement Between Owner and Contractor where the basis of payment is a Stipulated Sum (AIA
Document A101 - 2007 edition) and the General Conditions of the Contract for Construction
(AIA Document A201 - 2007 edition).
Any claims or disputes between the Contractor, Owner and/or Architect that cannot be resolved
through direct negotiation shall be submitted for non-binding mediation. The Contractor, Owner
and/or Architect agree to include a similar mediation agreement with all contractors,
subcontractors, sub consultants, suppliers and fabricators, thereby providing for mediation as the
primary method for dispute resolution between all parties. Claims or disputes that cannot be
settled through mediation shall be settled by arbitration, which shall be binding and conducted
under the rules of the American Arbitration Association.
00 73 00
Supplementary Conditions
General Contractor shall submit a fixed price proposal in a format that breaks the cost of trades
and various components of the project by appropriate Construction Specification Institute (CSI)
Master Format Divisions 0-48 (see list below and format of this specification), so that Owner
may evaluate the cost of the project and modify scope should that be necessary.
Division 00:
Division 01:
Division 02:
Division 03:
Division 04:
Division 05:
Division 06:
Division 07:
Division 08:
Division 09:
Division 10:
Division 11:
Division 12:
Division 13:
Division 14:
Division 15:
Division 16:
Procurement and Contracting Requirements
General Requirements
Existing Conditions
Concrete
Masonry
Metals
Wood and Plastics
Thermal / Moisture Protection
Openings
Finishes
Specialties
Equipment
Furnishings
Special Construction
Conveying Systems
Mechanical
Electrical
Division 21:
Division 22:
Division 23:
Division 26:
Division 28:
Division 31:
Division 32:
Fire Suppression
Plumbing
HVAC
Electrical
Electronic Safety and Security
Earthwork
Exterior Improvements
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 3 of 41
January 22, 2016
Pre-construction Services, Contractor Fees, and General Conditions shall be broken out as three
separate line items in Division #1
In addition, break out the cost for each of the following: Demolition, Site work, Building, Racks
/ Study cubicles.
Construction estimates should reflect the scope of work shown on the drawings and
specifications. Please do not "square foot" components of the project that can be "taken off"
from the drawings. Do not use historic pricing information for items that have been specified.
Subcontractor pricing should be used for significant trades. If you wish to submit alternates to
the products specified, they should be broken out separately, not included in the price. Include in
your estimate a list of any clarifications and/or assumptions you have made in pricing the project.
Also list allowances included for items not specifically defined in the documents. The estimate
submitted should reflect as closely as possible the cost of a fully finished and complete project.
Division 1: General Requirements
The purpose of these drawings is to convey design concept and scope of work. They are not
intended as comprehensive instructions defining every aspect of the work, or to cover all details
or specifications required to comply with generally accepted construction practices. It is the
Contractor's responsibility to provide trained, qualified field supervision and labor. The
Contractor shall include the materials and labor necessary for a fully finished and complete job
including permits, fees, etc.
All work, materials, assemblies, products and finishes used as a part of the construction
shall be installed in strict accordance with manufacturer's specifications and
recommendations.
For installation specifications of work not covered by manufacturer's specifications, the
Contractor shall use ASTM guidelines, government standards and/or industry/trade organizations
specifications and recommendations as the standard for installation.
The work shall be in accordance with applicable codes, ordinances, and other requirements
bearing on the conduct of the work.
Protect installed work during construction period to prevent damage and wear to finish surfaces.
Upon completion, clean installation as recommended by manufacturer of finish materials.
At the end of construction, provide Owner with all available warranty information and operating
manuals for appliances, HVAC, equipment, fans, etc.
01 10 00
Summary of Work
The scope of work involves construction of a new three story Sorority House and the associated
exterior hardscape, landscaping, and site work. The area of the building is as follows:
Main Level
Main Level
Main Level
Total Heated Floor Area
4,700 SF
4,700 SF
4,700 SF
14,100 SF
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 4 of 41
January 22, 2016
For Purposes of this specification, Public Areas shall be defined as those spaces open to the
public as follows:
Main Level: Foyer, Sitting Room, Living Room, Vestibule, Serving, Dining/Chapter
Room, Stair, Restroom
Second Level: Stair, Lounge, Laundry
Third Level:
Stair, Sign Painting, Study/Exec
01 11 16
Work by Owner
Material Supplied and Installed by the Owner and/or Separate Contractor(s)
A.
B.
C.
D.
Furnishings, including dressers and desks under Sleeping Racks and full length mirrors
Soils and material testing, including Special Inspections
Interior Signage – ASI Atlanta 404-815-0566
Permit and development fees including tap, meter, tree recompense and impact fees
imposed by the City of Atlanta and/or Georgia Tech University.
01 21 00
Allowances
The Contractor shall provide the following scheduled amounts in the contract sum:
1.
Landscaping and irrigation
$26,000
2.
Paver Brick
$485/m
3.
Sleeping Room Mattress
$150.00 / mattress
01 23 00
1.
2.
3.
4.
5.
Alternates
Provide a Payment and Performance Bond
Provide alternate Cultured Marble Countertops per Section 12 36 61.13.
Provide alternate Rubber Base at Sleeping Rooms, House Director Suite, Study / Exec.
Provide alternate to delete Door Casings at Second and Third Level Paneled Wood
Doors.
Provide alternate Metal Door Frame at Second and Third Level Panel Wood and Stair
Doors: Timely Industries – Classic Frame C-Series – TA-30 Steel Casing Option
http://www.timelyframes.com/products/door-frames/classic-timely-door-frames/
The Contractor is encouraged to submit additional alternates or cost savings suggestions with the
bid, but shall list them separately from the base bid and the alternates listed above. The Contract
Sum shall be based only on the products and systems specified in the Contract Documents.
Contractor proposed alternates will be considered separately. Contractor shall submit a detailed
description explaining the Proposed Alternates and describing their effect on Cost, Fee, and
Time Required for Construction.
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 5 of 41
January 22, 2016
01 25 00
Substitutions
If it is desired to use products different from those indicated in the Contract Documents, the
Contractor shall provide the Architect with sufficient data and/or samples as required to allow
the evaluation of the proposed change by the Architect and Owner. No exceptions will be
allowed without prior consent of the Architect.
01 33 00
Submittals
Contractor shall submit for Architect's approval, shop drawings, manufacturer's literature,
samples and other submittals as required by these specifications. Do not begin fabrication of
items requiring shop drawings, or purchase other items, without approved submittals. Shop
drawings shall be based on actual field dimensions. Should the Contractor fail to make the
required submittals in a timely manner, he shall be responsible for any required changes, at no
cost to the Owner.
01 43 39
Mockups
Provide a sample / mock-up wall panel at corner of the building from the Main Level to above
Second Level window sill brick band for Architect and Owner approval. Mockup shall include
brick veneer, mortar and section of brick sill. If approved, mockup may remain in place.
Provide a mock-up of one Bed Rack (see sheet A1.5) in Single Room for Architect and Owner
approval. Approved portions of the mockup may remain in place.
01 71 23
Field Engineering
Do not scale the documents. Contact the Architect when additional dimensions are required.
Unless noted otherwise, dimensions are to finished face of gypsum wall board, masonry or
concrete foundation wall. Where clear dimensions are noted, they are critical for clearance of
furniture or equipment and must be maintained.
Unless noted otherwise, inside face of door frames shall be located 6" from face of adjacent
perpendicular partition.
Dimensional layout shall be verified in the field prior to proceeding with the actual installation of
the work. All interior wall locations shall be laid out (chalked) on the floor deck prior to
proceeding with the installation of the wall framing. Contractor shall notify the Architect of any
discrepancies from stated dimensions or apparent dimensional problems.
Contractor is responsible for verifying quantities and dimensions, field measurements, and
related field construction criteria.
Division 2: Existing Conditions
02 41 00
Demolition and Salvage
See Civil drawings for the scope of demolition. Contractor to visit site to determine the scope of
work involved.
Project / Site Conditions
A. Conduct demolition operations and the removal of debris to ensure minimum interference
with roads, streets, walks and adjacent facilities.
B. Do not close or obstruct streets or walks without permission from authorities having
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 6 of 41
January 22, 2016
jurisdiction. Provide flagman where public thoroughfares are used for debris removal.
Maintain thoroughfares free of dirt and debris caused by demolition or hauling operations.
Division 3: Concrete
03 35 00
Concrete Finishing
Trowel Finish at Interior Floor Slabs
Broom Finish at Exterior concrete sidewalks, Landings, Balconies, Exterior Stairs at the Service
Yard.
Provide 1 1/4" deep saw cut control joints at interior slabs. Locate saw cuts under sill plate of
partitions when possible. Areas defined by saw cuts shall be close to square in shape. Provide
bond breaker (building paper or expansion joint material) at intersection of slab and concrete
basement walls.
Provide troweled control joints at exterior paving as shown on the drawings (20' o.c. maximum
each way).
Division 4: Masonry
04 05 13
Masonry Mortaring
Mortar shall be type "S" for below grade work, Type "N" for exposed work. Mortar mix shall
include Portland cement Type "I" (non-staining), hydrated lime Type "S", clean, hard, natural,
washed sand, and potable water. Materials and proportions shall meet appropriate ASTM
standards. Mortar color to be selected
04 05 19
Masonry Anchorage and Reinforcing
Masonry Veneer Anchors
Provide hot dipped galvanized two-piece adjustable metal veneer anchors at each stud spaced at
16" o.c. vertically. Install ties after Air Barrier is in place using stainless steel self-tapping
screws with sealing rubber gaskets to seal the penetration of the Air Barrier. Length of screws
shall be sufficient to securely anchor brick ties into metal studs.
Lintels
Provide galvanized steel lintels and shelf angles. Prime and paint exposed portions to match
brick per Section 09 90 00.
Mortar Net with Insect Barrier
Provide trapezoidal shaped Mortar Net with Insect Barrier to suspend mortar droppings at
unequal heights allowing moisture to drain from the cavity and maintain airflow within the
cavity wall. Install above the Through Masonry Flashing (See Section 07 27 00 Air Barrier &
Flashing System) at the bottom of all cavities behind the brick. Mortar Net shall be 10" high x
2" thick to fill the full depth of the 1 3/4" cavity. Drop into the cavity after the first 4 courses of
brick has been laid and mortar has set sufficiently to resist outward pressure from product.
Install per manufacturer’s instructions.
Manufacturer: Mortar Net USA, Ltd., 1-800-664-6638, www.MortarNet.com
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 7 of 41
January 22, 2016
Weeps: Install plastic weep holes/vents at 16" o.c. in the first course of brick above the Through
Masonry Flashing.
04 21 13
Brick Masonry
All brick and pavers are to be modular 7 5/8" x 3 5/8" x 2 1/4" Tumbled. All face brick and
mortar, including materials, storage, and installation, shall be in accordance with the American
Brick Institute of America "Technical Notes on Brick Construction #28B", dated August 1991.
Sources:
Georgia Masonry Supply,
404-391-1685
North Georgia Brick Co., Inc., 678-455-2551
Brick Schedule
B1 – Typical Field Brick:
Rep: Brad Wall
Type: Melrose - Tumbled
Mfr. Cherokee Brick and Tile
Typical Brick Paver*:
See Brick Allowance
Type: To Be Selected
Mfr. TBD
Brick Mortar:
Coosa Antique Buff
Coosa Masonry Cement
*Provide special shaped "Header Treads" for Front Porch, Outdoor Dining Porch Edge and Brick
Stair Treads.
Special shapes require 8 week lead time for delivery.
Submit grouted sample board including each brick and specified mortar color prior to ordering
brick and mortar.
Provide a sample / mock-up wall panel at Main Level from grade to above Second Level window
sill brick band for approval. See Exterior Elevations for location.
All face brick and mortar, including materials, storage, and installation, shall be in accordance
with the American Brick Institute of America recommendations and specifications. Install over
building paper installed per Section 7650.
04 22 00
Concrete Unit Masonry
Provide concrete block back up at Service Yard walls, cheek walls at front steps
04 72 00
Cast Stone Masonry
Provide "dry cast" cast stone lintels, gable parapet caps, accents blocks, wall caps, pier caps and
other special shapes as shown on the drawings. Color to be BUFF 25 as produced by Corbel
Stone. 778-455-2257. Finish shall be sand finish to resemble natural quarried limestone. All
reinforcing to be epoxy coated or hot dipped galvanized, or placed 2" minimum from finished
face. Provide 6" x 6" sample for approval. Provide shop drawings noting locations of joints,
dimensions of pieces, locations of attachments, etc. per the drawings.
Provide galvanized steel hanger system to support the cast stone at the Arched and Flat arch
openings at the Front and Rear Porches. See drawings.
Key Stone (Main Entry Arch)
Provide a Key Stone at the Main Entry Archway on the West (Front) Elevation of the building.
See the building Elevations
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 8 of 41
January 22, 2016
Provide 6” high "modified V-cut" Garamond letters as follows:
ΑΦ
Date Stone (Corner Stone)
Provide two faced, L-shaped Date Stone at southwest corner of the building.
Each face to be 15 5/8" high (6 brick courses) x 15 5/8" long (2 brick courses) x 3 5/8" deep with
6" and 1 1/2" high incised "modified V-cut" Garamond letters as follows:
Facing Brittain Drive (west):
ΑΦ
Sorority
Founded 1872
Facing Bobby Dodd Way (south):
ΙΜ
Chapter
Founded 2008
Division 5: Metals
05 40 00
Light gauge Metal Framing
Provide light gauge steel framing per the Structural Drawings and Partition Schedule in
accordance with the latest edition of AISI, "Specifications for the Design of Cold Formed
Structural Steel Framing Members" and to meet the local codes. Light gauge Metal Framing
design shall be engineered by a qualified professional engineer licensed in the state of the
project. Engineer is to prepare design calculations, shop drawings, and other structural data
based on the specific design properties of the Light gauge Metal Framing to be provided by the
manufacturer. Stud gauges shall be as required by manufacturer's product data for heights and
conditions of use, but 25 ga. minimum.
05 50 00
Miscellaneous Steel Fabrications
Locations:
North and South Exit Stairs
Front Balcony and Faux Balconies (4 total) at the Triple Rooms per the drawings
Furnish and install 3'-6" high Architectural Guardrail. Railing components shall be welded and
welds ground smooth and flush. Completed rail sections shall be galvanized and powder coated
with Kynar or equal fluoropolymer paint, per American Architectural Manufacturers Association
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 9 of 41
January 22, 2016
AAMA Specification 2605. Railing components are as follows:
Manufacturer:
King Architectural Metals, 1-800-542-2379, www.kingmetals.com
Material / Finish:
galvanized steel / powder coated with fluoropolymer paint
Newel Post:
3" square steel newel post with Cast Iron Post Cap #45-3002-3
Top Rail:
Steel Cover Rail 2 1/4" wide #45-908 on 1 1/2" x 1/2" steel channel
Bottom Rail:
1 1/2" square steel tube
Pickets /cross rail:
3/4" solid square pickets 4" o.c.
Decorative Arch:
1/4" x 1/2" bar stock
Newel attachment: Provide 2 1/2" steel tube extending 2' above the finished balcony to anchor
the Newel Post. Weld to the steel beam below and flash
1 ¼" o.d. painted metal handrails on steel brackets at both sides of run. Provide 1’ extension at
top and bottom of run and return end of handrails to wall.
Pit ladder at elevator pit, elevator sill angles, vanity support angles, grate covering the elevator
sump pit for the oil interceptor pump.
Furnish and install a 3'-0" high x 1 ½” thick 3-D Alpha Phi Bronze Crest into the center
Architectural Guardrail at the Front Balcony. Completed Crest section shall be bronze to match
guardrail color. Railing Crest is as follows:
05 73 00
Architectural Railings
Furnish and install Architectural railings at the following locations:
Front Outdoor Dining Porch steps and Front Entry Steps
Material / Finish:
Vertical Posts:
Vertical Balusters:
Top Rail:
Bottom Rail:
Cross Rails:
Top Section:
galvanized steel / powder coated with fluoropolymer paint
2" square steel tube
5/8” square steel bar
5/8” x 2” wide flat bar
5/8” x 1” wide flat bar
5/8” x 1” wide flat bar
3/8” square bar stock in diamond pattern.
All connections to be welded unless noted otherwise. All welds to be ground smooth and flush.
Completed rails shall be galvanized and powder coated with Kynar or equal fluoropolymer paint,
per American Architectural Manufacturers Association AAMA Specification 2605. Railing
components and configuration are as indicated in the drawings.
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 10 of 41
January 22, 2016
Furnish and install 3'-6" high Architectural Guardrail at Front Balcony and Faux Balconies (4)
per the drawings. Railing components shall be welded and welds ground smooth and flush.
Completed rail sections shall be galvanized and powder coated with Kynar or equal
fluoropolymer paint, per American Architectural Manufacturers Association AAMA
Specification 2605. Railing components are as follows:
Manufacturer:
Material / Finish:
Newel Post:
Top Rail:
Bottom Rail:
Pickets /cross rail:
Decorative Arch:
Newel attachment:
King Architectural Metals, 1-800-542-2379, www.kingmetals.com
galvanized steel / powder coated with fluoropolymer paint
3" square steel newel post with Cast Iron Post Cap #45-3002-3
Steel Cover Rail 2 1/4" wide #45-908 on 1 1/2" x 1/2" steel channel
1 1/2" square steel tube
3/4" solid square pickets 4" o.c.
1/4" x 1/2" bar stock
Provide 2 1/2" steel tube extending 2' above the finished balcony to anchor
the Newel Post. Weld to the steel beam below and flash.
Division 6: Wood and Plastics
06 10 00
Rough Carpentry
All wood in contact with concrete or masonry shall be pressure treated.
Provide wood blocking in partitions where decorative light fixtures, casework, etc. are indicated
to be supported by the wall or ceiling. All wood blocking shall be fire treated such that it is
considered non-combustible.
06 40 23
Interior Architectural Woodwork
Provide paint grade*, shop fabricated, site installed Interior Architectural Woodwork
fabricated to AWI "Custom" Quality Standard Grade in the following areas:
Living Room #112 – Room Divider
Base Cabinet with Stile and Rail doors, Quartz
Counter and upper 2-sided shelves
Dining/Chapter Hall #119 - Buffet
Base Cabinet with Stile and Rail doors and Quartz
Counter
Base Cabinet with Stile and Rail doors and Quartz
Counter
Base Cabinet with Stile and Rail doors and Upper
Wall Cabinets with Quartz Counter
Base Cabinet with Stile and Rail doors and Quartz
Counter
Dressing Area:
Base Cabinet with 22 individual Lockable Drawers
and Quartz Counter
Vanity Area:
Base Cabinet with Stile and Rail doors at left and
right vanities, open at center vanity with valance
panel and Quartz Counter
Serving #104
Sister Kitchen #118
Bathrooms #108, #109
Women’s Bathrooms #215
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Women’s Bathrooms #313
Laundry #216
Bath #213
Study/Exec #318
Sign Design #314
Page 11 of 41
January 22, 2016
Dressing Area:
Base Cabinet with 22 individual Lockable Drawers
and Quartz Counter
Vanity Area:
Base Cabinet with Stile and Rail doors at left and
right vanities, open at center vanity with valance
panel and Quartz Counter
Base Cabinet with Stile and Rail doors and Upper
Wall Cabinets with Cultured Marble Counter
Base Cabinet with Stile and Rail doors and Cultured
Marble Counter
30” deep Cultured Marble Counter w/ two equally
spaced 3/4" thick angled supports with Upper Wall
Cabinets
Storage Cabinet with Stile and Rail doors
Sink Base Cabinet with Stile and Rail doors and
Cultured Marble Counter
Cabinets to be custom fabricated, face frame boxes – Stile and Rail doors.
Preapproved Millwork Shops:
Division Six (formerly PCI)
Pierce and Pierce
Tim Miller
Billy Crumpton
678-616-6000 ext. 105
770-448-8350
Millwork shops should have the capability of preparing shop drawings, fabricating, installing and
finishing the millwork. Other qualified shops will be considered at the request of the Contractor.
Lumber and plywood shall be paint grade poplar. Millwork shall be field painted.
Submit shop drawings indicating proposed materials, component profiles, fastening methods,
jointing details, hardware locations, frame clearances etc. Do not begin fabrication of any items
without approved shop drawings. Shop drawings shall be based on actual field dimensions.
Minimum scale for details shall be half scale.
Project Conditions:
Do not deliver or install woodwork until building is enclosed, wet work is complete, and HVAC
system is operating and maintaining temperature and relative humidity at occupancy levels
during the remainder of the construction period.
Cabinets to be custom fabricated – full overlay flush face doors.
Submit dimensioned shop drawings of Architectural Woodwork indicating proposed materials,
component profiles, fastening methods, jointing details, hardware locations, cutouts for junction
boxes, frame clearances etc.. Shop drawings shall be submitted in the form of two sets of prints.
Shop drawings shall be based on actual field dimensions. Minimum scale for details shall be
half scale. Do not begin fabrication of any items without approved shop drawings. See Section
01 33 00 - Submittals.
Hardware for Architectural Woodwork
Pulls
Hafele nickel-plated steel pull #117.31.6332 with overall dimension
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 12 of 41
January 22, 2016
of approx. 1 1/8" x 6" (30 mm x 156 mm), provided with attaching
screws
Richelieu, Expression, Transitional Metal Handle Pull #7653
Product Number: BP765128BORB
Finish: Brushed Oil-Rubbed Bronze (BORB)
Size: 5-1/32” center-to-center, 6-17/32”L, 1-5/16” projection
Location: Sister Kitchen #118 and Serving #104 Base Cabinet Drawers
Note: Refer to interior elevations for further information; Packaged
with 8/32 screw
Richelieu, Expression, Contemporary Metal Handle Pull #305
Product Number: BP30576195
Finish: Brushed Nickel (195)
Size: 3” center-to-center, 6-5/32”L, 1-3/8” projection
Location: Base and Wall Cabinet Doors in Laundry #216 and Supply
Closet #316
Note: Refer to interior elevations for further information; Packaged
with 8/32 screw
Knobs
Richelieu, Expression, Transitional Metal Knob #7653
Product Number: BP76533BORB
Finish: Brushed Oil-Rubbed Bronze (BORB)
Size: 1-5/6”x 1-5/6”, 1-1/4”projection
Location: Sister Kitchen #118 Base and Wall Cabinet Doors, Serving
#104 Base Cabinet Doors
Note: Refer to interior elevations for further information; Packaged
with 8/32 screw
Richelieu, Expression, Transitional Metal Knob #7653
Product Number: BP76533180
Finish: Nickel (180)
Size: 1-5/6”x 1-5/6”, 1-1/4”projection
Location: Bathrooms #215, #213, and #314 base and wall cabinet doors
and drawers
Note: Refer to interior elevations for further information; Packaged
with 8/32 screw
Wall Hooks
Richelieu, Transitional Metal Hook #1173
Product Number: RH1173021BORB
Finish: Brushed Oil-Rubbed Bronze
Size: 5-1/8”H x 1-31/32”W, 3” projection
Location: Backpacks/Coats #117
Note: Refer to interior elevations for further information
Submit samples of pulls, knobs and hooks to Architect for review.
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 13 of 41
January 22, 2016
Drawer Glides:
"Accuride", zinc chromate-plated steel with steel ball bearings,
mounted in routed drawer sides, aligning. Quick disconnect feature on
drawer glides. Drawers equipped with 3/4 extension glides with load
carrying capacity of 100 lbs.
Hinges:
"Blum" or "Grass" clip-on, nickel plated metal, 125 degree, six-way
adjustable concealed, self-closing hinges for 3/4" thick doors. Doors
greater than 48" tall to receive 170-degree heavy-duty hinges. Number
of hinges per door as specified by hinge manufacturer.
Shelf / supports:
Provide heavy duty adjustable shelves on 5 mm nickel-plated steel,
positive locking supports, four per adjustable shelf. Provide holes at 32
mm on center to receive shelf supports.
Cabinet locks:
Door and drawer locks of steel and zinc alloy, five plate levers provided
with two keys per lock. Up to four locks may be keyed alike or any
number of individually keyed locks may be accessed with master key.
Grommets:
Provide 2 ½" Ø black plastic grommets where indicated. Size to
accommodate communication cables. See electrical plan for locations
of under-counter electrical, and data outlets.
Silencers:
Provide two self-adhesive bumper pads for each cabinet door and
drawer. Mount on drawers and doors (not frame).
06 46 00 Wood Trim
Project Conditions: Do not deliver or install woodwork until building is enclosed, wet work is
complete, and HVAC system is operating and maintaining temperature and relative humidity at
occupancy levels during the remainder of the construction period. Trim to be climatized for
72hrs prior to installation.
Exterior Trim
Exterior dimensional wood trim and moldings shall be smooth-face cellular PVC trim.
Typical Window/Door Casing:
AZM-6931 backband on 5/4x4 Azek trim board*
*back band to be mitered, head trim board to extend
over jamb trim (not mitered)
Typical Window Sill:
AZM-6930 Historic Sill – extend to outside of backband
Crown at Porch Ceilings:
AZM-80 4 1/4" Cove Crown
Provide alternate price to provide 3 ½” wide brick mould and sill extension, factory
installed extruded aluminum profiles by window manufacturer in finish to match clad
windows and doors.
Interior Trim
Wood species:
Painted Trim at Public Areas:
Painted Trim at Sleeping Rooms:
paint grade poplar
paint grade white pine finger jointed
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 14 of 41
January 22, 2016
See Finish Schedule for locations of interior trim, drawings for exterior trim.
Refer to interior elevations for details of wood trim.
Trim shall match the profiles specified below of Randall Brothers, Inc. Atlanta, GA 404-8926666 (see "RB" numbers below).
Door/ Cased
Opening Casing
CS-1 = 1x4 with RB9940 backband and RB 174 casing bead with
3/4" x 5 1/4" x 9 1/4" plinth – block out casing
Window Casing
CS-1 = 1x4 with RB9940 backband and RB 174 casing bead with
1" thick ogee window stool and CS -1 apron with mitered ends returned
to wall
Door Casing
CS-2 – RB8808 backband on hollow metal door frame
Window Casing
CS-3 – RB8846 casing with 3/4" thick ogee window stool & CS -3 apron
w/ mitered ends returned to wall
Wood Base
B-1 - 1x 8 base with base cap (RB 9923) and shoe mold (RB 31)
B-2 - 1x 6 base with base cap (RB 174)
Door Casing
Window Casing
CS-4 = 1x4
CS-4 = 1x4
Rubber Base
B-6 – 4” high
Chair rail cap
Wood Paneling
Wainscot
CH-1 – match RB9897 capital molding w/ back rabbet at top of WS-1 –
36”AFF – with Wood Paneling Wainscot
CH-2 – 4 3/4" x 1 1/4" custom profile at top of WS-2
Location:
Door capital
Location:
Crown
CH-3 – RB33 - 1/2" x 2" at top of Prefinished Wood Paneling (PWP-1)
Foyer 113, Living 112, Sitting 111, Dining / Chapter Room 119
Top of doors and cased openings as indicated in schedule
DC-1= match RB9874 cove with 2" high trim cap mounted on top of and
proud of CS-1 w/ mitered ends returned to wall
Overall height: 4 3/4" Projection: 2 3/4" beyond face of CS-1
CR-1 - three-piece crown – RB 9872 w/ RB 8801 apron on 1x6
Overall height: 12"
Projection: 5 1/8"
CR-2 - two-piece crown – RB 9872 w/ RB 8801
Overall height: 6 1/2" Projection: 4 3/8"
Pilasters/Gyp Bd. Columns
Location:
Foyer, Living Room, Sitting Room, Dining/Chapter Room
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 15 of 41
January 22, 2016
PIL-1 = RB 9872 Crown Mould with RB-9898 Neck Mould and RB-1
Base.
Picture Mould
Location:
Dining/Chapter Room
PM-1 = RB 273 Picture Mould
Interior Carpentry
Provide Finish Carpentry in the following areas:
Clear Birch Plywood and Yellow Pine lumber stained:
Sleeping Room Racks
06 61 13
Cultured Marble Fabrications (WC-8)
Location/Height: Showers, including drying/changing area
96" high
Wall panels:
Jamb:
Pan:
Casing:
1/4" thick x 96" x 60"sheets
wall panel material - provide as jamb at cased shower openings
Formed floor pan, sloped to drain with integral curb.
3/4" thick x 108" x 2" wide - provide as casing at cased shower openings,
outside of shower only (no CMP casing at CMP panels inside shower area)
Accessories:
Provide one recessed soap / shampoo niche at each shower.
Provide 12”x12”x3/4” foot rest at showers-typ.
Sealant:
Seal the joints with 100% silicone sealant.
Finish/Color:
Matt Finish #501 Solid White
Source:
Construction Resources, Inc. 404-378-3132
See specification section 12 36 61.13 for Cultured Marble Countertops
06 82 00
Glass Fiber Reinforced Plastic (FRP) Composite Fabrications
Decorative Column Covers
Location:
Columns at Outdoor Dining Porch (total of 4 plus 2 half columns)
Product:
FRP Classic Fiberglass Column Covers
Style:
#200FRP Tuscan Square
Dimensions:
14” x 14” square shaft
Finish:
Painted
Manufacturer:
Melton Classics www.meltonclassics.com
Columns are not structural
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 16 of 41
January 22, 2016
Division 7: Thermal and Moisture Protection
07 14 00 Deck Waterproofing System
Location: Below the concrete topping slab at Front and Rear Balconies
Acceptable materials manufactured by Grace Construction Products:
Bituthene Deck System: cold applied waterproofing system for elevated decks that includes the
following primary components:
Deck Primer
Cold fluid applied surface treatment to level / prepare concrete deck Bituthene Deck Prep
Deck Waterproof Membrane & Perimeter Wall Flashing
Self-adhesive rubberized asphalt/polyethylene waterproof membrane Bituthene 300
Drainage Composite
Prefabricated geo-composite drain / protection layer
Hydroduct 220
Drain Flashing
Bituthene Liq'd Membrane
Install Drainage Composite on top of the Waterproof Membrane with outlet into two level deck
drain equal to Jay R. Smith 2010C Floor Drain with Adjustable Height Strainer and Flashing
Collar to receive membrane and Weep Holes to allow water from drainage composite into drain.
Flood test the completed Deck Waterproofing System prior to placing the topping slab.
Membrane and associated accessories shall be installed in strict accordance with manufacturer's
specifications by an applicator experienced in the installation and with the application
techniques.
Local Representative: Jason Monday 770-928-6457
07 16 00
Metallic Waterproofing
Install metallic water proofing with topping slab in the elevator pit.
07 19 00
Water Repellent Sealer
Apply water repellent penetrating clear sealer to the concrete at the top level of topping slab at
Front and Rear Balconies.
07 21 16
Batt Insulation
Thermal insulation at exterior building envelope shall be fiberglass batt insulation with KraftFaced paper vapor barrier toward "conditioned" side.
Location
Exterior Walls
Thickness
5 1/2"
R value
R-21
Provide and install thermafiber fire rated fiberglass batt insulation at rated fire barriers, typical.
Provide and install fire rated sound attenuating fiberglass batt insulation at rated sleeping room
partitions and floor ceiling assemblies.
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 17 of 41
January 22, 2016
Location: - R-38 batt insulation at attic floor.
07 24 00 Exterior Insulation and Finish System (EIFS)
Location: Front Porch Ceiling
Outdoor Dining Patio Ceiling
Exterior Insulation and Finish System shall be Sto Premier NExT by Sto Industries (1-800-2212397) or equivalent system by Dryvit Systems, Inc.. Use with 1 1/2" thick expanded polystyrene
board to allow adequate depth for architectural reveals. Install EIFS with manufacturer trained
and certified applicators. Use manufacturer standard mesh. Prime with appropriately tinted
primer before applying finish coat. Finish shall "StoSilco Lit 1.0 Finish". Color to be selected
from manufacturer's standard selection
07 26 13
Vapor Barriers
Vapor barrier:
Location: typical interior slabs on grade
Install 15 mil thick black polyethylene sheeting over compacted, clean subgrade, free of debris
and protrusions, under interior slabs on grade. Install in large sheets so as to minimize seams.
Lap edges 12" minimum and use manufacturer recommended tape at seams to hold sheets in
place. Cut neatly around pipes and other protrusions.
07 27 00
Air Barrier & Flashing System
Acceptable materials manufactured by Grace Construction Products:
Air Barrier:
Self-adhering vapor permeable air barrier membrane sheet
installed over Prem-A-Barrier Primer Plus primer
Perma-Barrier VPS
Location: applied to outside of sheathing above grade at exterior walls
Alternate Air Barrier:
Fluid applied vapor permeable air barrier membrane: Vycor enV (60 mil wet / 30 mil dry film
thickness)
Location: applied to outside of sheathing above grade at exterior walls
Through Masonry Flashing:
Self-adhesive, rubberized asphalt/polyethylene flashing
Locations:
Perm-A-Barrier Wall Flashing (green)
flashing above lintel angles supporting masonry
flashing above finished grade at:
transition flashing from air barrier to below grade waterproof membrane
flashing above aluminum flashing at the top of the grouted cavity
under the cast stone coping and at cast stone at the projecting bays
other obstructions to the downward flow of water the cavity behind brick
Membrane Flashing:
Aluminum faced self-adhesive flashing membrane: Vycor Aluminum Flashing (25 mil)
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 18 of 41
January 22, 2016
Locations: flashing at sheathing around windows, doors and other openings
Air Barrier / Flashing sequencing at Door and Window Openings:
1. Install Membrane Flashing at window/door sills prior to applying the Air Barrier. Turn up 4"
minimum up the jambs / and outside face of the sheathing on each side of opening.
2. Install Air Barrier prior to installing the windows and doors. Extend Air Barrier 3" minimum
into the openings.
3. Install Membrane Flashing at window/door jambs and head after the Air Barrier to allow the
flashing to overlap the window nailing flange. Install jamb flashing followed by head flashing
extending 3" minimum onto Air Barrier from nailing flange. Apply Bituthene liquid membrane
at the top edge of head flashing to seal to the air barrier.
Installation requirements:
Install using Grace Specialist Applicators trained and experienced in the application of the
specified products.
Prepare surfaces per manufacturer's requirements.
When properly positioned, place flashing against surface by pressing firmly into place by hand
roller.
Overlap adjacent pieces 2" and roll all seams with a hand roller.
Seal top edge of flashings with termination mastic.
At heads, sills and all flashing terminations, turn up ends a minimum of 4" and make careful
folds to form an end dam, with the seams sealed.
Do not allow the rubberized asphalt surface of the flashing membrane to come in contact with
poly-sulfide sealants, creosote, uncured coal tar products or EPDM.
Alternate Air Barrier: Spray or trowel apply a continuous uniform film at min. 60 mil (.060 in.)
dry film thickness using multiple, overlapping passes. When spraying use a cross-hatching
technique (alternating horizontal and vertical passes) to ensure even thickness and coverage. Use
high pressure, multi-component, airless spray equipment approved by material manufacturer.
Seal all brick-ties and other penetrations as work progresses.
Air Barrier and associated accessories shall be installed in strict accordance with manufacturer's
specifications by an applicator experienced in the installation and with the application
techniques.
Contact Local Representative for further details of local applicators, application techniques and
spray equipment.
Local Representative: Jason Monday 770-928-6457
07 27 16
Roof Shingle Underlayment
Location: applied to the roof deck before installing Roof Shingles
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 19 of 41
January 22, 2016
Acceptable materials manufactured by Grace Construction Products (or approved equal):
Roof Underlayment:
Grade Tri-Flex, 7 mil high performance roof underlayment, as manufactured by W.R. Grace, &
Co.. Provide to the owner with an executed copy of the manufacturer's Limited Warranty against
Manufacturing Defect.
Ice and Water Shield within 3' of Coping, Eave and Valleys and Ridge:
Grace Ice and Water Shield, 40 mil self adhered roof underlayment as manufactured by W.R.
Grace, & Co.. Provide to the owner with an executed copy of the manufacturer's Limited
Warranty against Manufacturing Defect.
Underlayment and associated accessories shall be installed in strict accordance with
manufacturer's specifications by an applicator experienced in the installation and with the
application techniques.
Local Representative: Jason Monday 770-928-6457
07 31 13
Fiberglass Reinforced Asphalt Roof Shingles
Roofing shall be GAF "Camelot II" dimensional high-definition fiberglass asphalt shingle
roofing (or APPROVED equal by Owens Corning or Celotex).
Use matching starter strip shingles and ridge cap shingles.
Color:
Antique Slate
Submit sample board to Architect for approval before ordering.
See Section 07 71 00 Prefabricated Roof Specialties for metal roof and edge flashing
specifications.
Ridge Vent: GAF - Cobra Rigid Vent 3
07 61 13
Standing Seam Metal Roofing
Provide standing seam metal roofing on roofing felt over plywood sheathing on metal stud
framing at roof pyramid over the lobby. Roofing shall be 24 gauge coil coated steel with 1"
standing seams at 1'-0" o.c. equal to "Tee-Panel" standing seam metal roof by Berridge
Manufacturing Company. Finish shall be two coat shop-applied, baked on fluoropolymer
coating system based on Pennwalt Corp., Kynar 500 resin. Color to be "UC-51733, Hartford
Green" by PPG.
07 71 00
Prefabricated Roof Specialties (gutters, downspouts, drip edges, soffit vent)
Install Prefabricated Roof Specialties per the requirements of Sheet Metal & Air Conditioning
Contractors National Association, Inc. (SMACNA). Figures referenced here are from the
Architectural Sheet Metal Manual (Fifth Edition, 1993).
Gutters and downspouts shall be pre-finished aluminum. Submit samples of color finish for
approval.
Gutters shall be .051" aluminum 5" box style (Fig. 1-2 Style A). Box gutters shall be screwed
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 20 of 41
January 22, 2016
through the fascia into the roof framing at 18" o.c. maximum and supported by Spike and Ferrule
(spacer) 3' maximum o.c. (Fig. 1-18C).
Downspouts shall be .051" aluminum 5" plain round downspouts (Fig. 1-32A). Downspouts
shall be supported by shop fabricated downspout hangers at 10' maximum o.c. (Fig. 1-35D)
screwed into the brick.
Drip edge: Shall be continuous, prefinished (color to match adjacent trim color) aluminum drip
edge at eave conditions prior to installing felt underlayment. Drip edges should extend 3" back
from the roof edge and bend downward to cover the thickness of decking into gutter.
Attachment should be with appropriate nails spaced 8" to 10" apart along the inner edge (Fig 422C at Rake and 4-22D at eaves) Submit sample of color finishes for approval.
Soffit Vent: Shall be continuous, prefinished (color to match adjacent trim color) aluminum
soffit vent at perimeter roof eave conditions. GAF LSV8 Series
07 84 00
Firestopping
Provide firesafing and fire caulk at penetrations through fire rated partitions and floor
penetrations.
07 92 13
Sealants and Caulking
Install sealant around window and door jambs, electrical, plumbing and other penetrations in the
envelope, including expansion and control joints. Sealant on exterior shall be Dow 790 silicone,
with continuous backer rod. Color to be standard Dow color as selected by the Architect.
Provide samples for selection.
Division 8: Doors and Windows
08 06 10
Door Schedule – See Drawing Set
Hardware Schedule to follow.* see Door Hardware section 08 71 00 - I. Exit Devices for
detailed information on panic device hardware
08 11 00
Hollow Metal Doors and Frames
Hollow metal doors shall be Grade II/Model 1, 16 gauge hollow metal doors. Provide insulated
doors at exterior locations. Hollow metal frames at exterior doors are to be 14 gauge,
galvanized, fully welded type with mitered head and jamb connection. Hollow metal frames at
interior doors are to be 14 gauge, knock down type with mitered head and jamb connection.
Provide manufacturer's standard anchors for securing frames to metal studs, wood framing, block
or supporting structure. Provide one anchor for each 2'-0" of height or fraction thereof.
Reinforce frames as necessary to accept, and securely support, scheduled hardware (without
through bolting). Doors and frames shall be fabricated according to Steel Door Institute
Publication 100. Fire rated doors and frames shall meet the requirements of NFPA #80 with
factory installed Underwriters' Laboratory Labels.
Acceptable Manufacturers:
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 21 of 41
January 22, 2016
Ceco Door
Curries Company
Republic Doors and Frames
Steelcraft
08 14 16
Interior Flush Wood Doors
Interior flush wood doors shall be 1 ¾" thick, five ply construction with particleboard cores
(except at rated doors) fabricated according to NWWDAIS-1. Fire rated doors shall have
composite edging and blocking and shall comply with the requirements of UL10C Category A.
Fire rated doors and frames shall meet the requirements of NFPA #80 with factory installed
Underwriters' Laboratory Labels. See door schedule for sizes and finishes.
Finish: rotary cut birch veneer to receive paint finish
Acceptable Manufacturers:
Algoma Hardwoods, Inc.
Doormerica
Eggers Industries
Marshfield Door Systems
Osh Kosh Door Company
08 14 33
Paneled Wood Doors
Exterior Paneled Wood Doors
Custom stile and rail wood doors and transoms shall be fabricated from solid stock lumber (or
built up from laminated lumber but not veneered) according to AWI Section 1400.
Doors E101, E102, E103, E104, E201 including Transoms and Sidelites
Manufacturer:
Lag Design, 561-841-8590
Thickness/Sizes:
2 ¼” thick x size indicated in schedule
Rating:
See door schedule – 20 Min. at Second and Third Level Corridor Doors
Quality:
AWI premium grade, stave core.
Door Material:
Lumber shall be Plain sawn Honduras Mahogany. and plywood shall be
Plain sawn Honduras Mahogany veneer to match the solid lumber
Frame Material:
To match Door material.
Glass:
Simulated divided lites with bronze colored spacer bar, muntin profile to
be 7/8” wide, interior and exterior
Hardware Prep :
Prep for Hardware specified in the Hardware Schedule
Finish:
Stained Finish by millwork shop to match Architect’s sample.
Interior Paneled Wood Doors
Product:
Millennium Encore Laminated MDF Solid Core Door router carved to create
simulated raised panels - Intumescent Core where required for door rating
Design No."
Two Panel – 1000 Series Flush #6102
Profile:
"Standard" Sticking Profile
Door thickness: 1 3/4"
Sizes:
See door schedule
Rating:
See door schedule
Finish:
Primed ready for paint
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Manufacturer:
Page 22 of 41
January 22, 2016
Doormerica 1-888-454-2888
08 31 00
Access Doors
Provide access panels to access MEP systems:
Material:
14 gage steel door and mounting frame.
Access Door:
Flush to edge of frame.
Frame:
Galvanized steel drywall taping bead on all sides.
Hinges:
Continuous, concealed
Latch:
Stainless Steel screwdriver operated cam latch.
Rating:
As required in rated walls and assemblies
Finish:
Five-stage iron phosphate preparation with prime coat of gray baked
enamel, field painted to match the wall or ceiling.
Acceptable Manufacturers:
Babcock-Davis
JL Industries
Larsen's Manufacturing Company
Williams Brothers
08 33 23
Overhead Coiling Door
Provide rolling counter door with integral frame and countertop at Dish Return and Serving Line
at Serving 104B. Face Mounted Unit with hood enclosure on the Kitchen side. Push up
operation. Provide slide bolt and hasp locking.
Model No.:
ESC20
Location/Size:
Dish Return - 3'-0" wide x 4'-0" high – counter at 34"AFF
Door Finish:
aluminum with a clear anodized finish
Frame/Counter Finish: stainless steel #4 finish
Manufacturer:
Cornell Iron Works
Source:
Atlanta's Professional Door, Inc., 770-460-6688
08 52 13
Aluminum Clad Windows and Doors
Aluminum Clad Windows and Doors shall be factory assembled wood casement windows with
extruded aluminum exterior to match Axiom Casement Windows manufactured by Eagle 1-855324-5314 or approved equal by Marvin, Quaker or Kolbe.
Door Locations: E101, E102, E103, E104, E201
Individual windows shall be factory ganged (mulled together) in the quantity indicated by the
sub-number shown next to the window type letter, i.e. A3 requires three "A" windows to be
combined as a single unit.
Glazing in doors and windows shall be insulated clear High-Performance Low-E4 Glass,
tempered where required by code.
Muntins shall be 7/8" wide simulated divided lights with spacer bar and Colonial interior profile.
Muntins shall be permanently affixed to the interior and exterior surfaces of the glass. Muntin
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 23 of 41
January 22, 2016
patterns shall be as indicated on the drawings.
Exterior aluminum clad wood doors shall be outswinging commercial construction matching the
elevations on the Door Schedule. Prep doors to received scheduled hardware including ADA
compliant sills.
Exterior finish of the aluminum clad wood doors and windows shall be Kynar or equal
fluoropolymer paint. Color to be selected
All window/door interiors shall be factory-primed wood, painted per Section 9900.
Screens are not required.
Exterior casing shall be factory applied Adams casing with sill nose. Space mulls shall be
factory applied extruded aluminum, in sizes indicated on drawings. Provide jamb extensions to
match wall thickness.
Windows shall be properly installed, flashed and sealed per the recommendations and details of
the manufacturer – see Spec. Section 072700.
Sizes and configurations shall be as listed on the Window and Door Schedules and indicated on
the drawings. Provide window and door schedule of manufacturer model numbers and shop
drawings of matching custom windows for architect's approval.
08 71 00
Door Hardware
See Door Hardware section following this specification.
Division 9: Finishes
Finish work shall be smooth, free from abrasion, tool marks, raised grain, etc. on all exposed
surfaces.
Contractor shall be responsible for proper substrate preparation prior to installation of any finish
materials including cleaning, patching, sanding, priming, etc..
All finishes and materials shall be as indicated in the interior finish plans and legend. No
substitutions will be accepted without written approval by the Architect.
09 06 00
Finish Legend
Refer to Finish Legend on I1.1
09 21 16
Gypsum Board Assemblies
Basis-of-Design Product: The design for each type of gypsum board and related products is
based on products of G-P Gypsum 1-800-225-6119 or United States Gypsum 404-202-8792
named below. All gypsum wallboard construction and materials shall be installed per the
recommendations and standard practices of the manufacturer.
Exterior Sheathing
GP - DensGlass Sheathing
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 24 of 41
January 22, 2016
USG - Securock Glass Mat Sheathing
Exterior Sheathing rated
GP - DensGlass Fireguard Sheathing
USG - Securock Glass Mat Firecode Sheathing
Impact Resistant** (Stairs and Corridors)
GP - DensArmor Plus Impact-Resistant Interior Panels
USG - Mold Tough VHI Impact-Resistant Interior
Panels
Impact Resistant rated** (Stairs and Corridors)
GP - DensArmor Plus Fireguard Impact-Resistant
Interior Panels
USG - Mold Tough VHI Impact-Resistant Interior
Panels
GP - DensArmor Plus Abuse-Resistant Interior Panel
USG - Sheetrock AR
Abuse Resistant (behind wood paneling)***
Bathroom, janitor closet, kitchen walls/ceilings
GP - DensArmor Plus High Performance
USG - Mold Tough Regular/Firecode
Bathroom Walls (behind tile)
GP - DensShield Tile Backer
USG - Mold Tough Regular/Firecode
Shower Wall (behind Cultured Marble)
GP - DensShield Tile Backer*
*The grey face of DensShield Tile Backer has a heat cured acrylic coating which is a built-in
moisture barrier / vapor retarder. No additional moisture barrier is required over panels. Butt
panels tight and tape the joints between Tile Backer panels with WallSeal membrane by Nobel
Company (composite membrane made from PVC with polyester fabric laminated to both sides)
cut into 12" wide strips to seal the joints between sheets. Set membrane in Noble Bond EXT
adhesive or latex modified thin set adhesive.
** Impact resistant gypsum board is only required to 8'-0" above the finished floor. Gypsum
board without the impact resistant rating may be used on the wall above 8'-0". Provide a skim
coat (level 5) finish over the exposed glass mat facing of GP - DensArmor Plus. This skim coat
will be required to achieve an acceptably smooth wall.
*** Abuse resistant gypsum board may be installed in lieu of Impact resistant gypsum board
where gyp. bd. is covered by wood paneling.
Gypsum wall board to be 5/8" thick unless noted otherwise. All gypsum wallboard outside
corners shall have continuous metal corner beads.
09 30 00
Manufacturer:
Source:
Thickness:
Grout joint width:
Grout material:
Porcelain Tile – Refer to Finish Legend
Crossville, Inc., 931-484-2110, www.CrossvilleInc.com
Specialty Tile Products, Inc, 404-264-0727
10.5 mm (+/-7/16")
3 mm (1/8")
Sanded grout – apply color matched sanded sealant at all inside corners and
where tile abuts dissimilar materials
Grout color:
Warranty:
Submit samples of colors for selection by Architect.
10 year commercial warranty
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 25 of 41
January 22, 2016
Contact Source eight weeks prior to installation to assure availability.
T-1 - Typical Restroom and Bathroom Floor Tile
Product Line:
Shades
Color:
AV245 Clay (gray) w/ UPS (matte) Finish
Dimensions:
12" x 24" nominal in running pattern typical
12" x 24" nominal in basket weave w/ T-2 in Main Level Bathrooms
Coordinating Trim: 6" x 12" Cove Base
T-2 - Accent Tile
Product Line:
Color:
Dimensions:
T-3 - Wall Tile
Product Line:
Color:
Dimensions:
Coordinating Trim:
Shades
AV249 Ink (black) w/ UPS (matte) Finish
6" x 24" cut into 6" x 6" tiles –
in basket weave pattern with T-1 in Main Level Bathrooms
Shades
AV241 Frost (white) w/ Honed (gloss) Finish
12" x 24" nominal - laid in running bond pattern
4" x 24" Single Bullnose at top of wainscot
Tile Wainscot shall be 5'-9" nominal height, typical at Restrooms and Bathrooms at wet walls
behind toilets and urinals. Provide and 18” wide wainscot return at all side walls adjacent to
urinals : 6” cove base + 5 tile courses + 4" bullnose tile at top. See drawings for the starting
point for tile layout.
T-4 – Floor Tile and Base Tile
Product Line:
Color:
Dimensions:
Coordinating Trim:
Bluestone
AV201 Colorado Buff w/ Honed Finish
12" x 24" nominal - laid in herringbone pattern
4" x 24" Single Bullnose – used as Wall Base
Provide transition strips by "Schluter-Systems" :
Between Porcelain Tile / Seamless Flooring: SCHIENE Profile:
Between Porcelain Tile / Resilient Flooring: RENO-U Profile:
Between Porcelain Tile / Carpet:
RENO-TK Profile:
Source: Specialty Tile Products, Norcross, GA (770) 246-9224.
1 1/2" high stainless steel
9/16" high stain. steel 304
1/2" high stain. steel 304
Install per the following Tile Council of America (TCA) installation specifications:
Concrete slab installations:
#F111-06
2" deep thick set on crack isolation membrane concrete slab on grade
Wood framed floors installations:
#F141-06
1 1/2" thick set on 3/4" plywood deck with waterproof membrane
Wall / Wainscot installations:
#W244-06
on tile backer board – see Section 09 21 16
09 33 00
Quarry Tile – Refer to Finish Legend
Product Line:
Florida Brick and Clay (FBC)
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Color:
Dimensions:
Coordinating Trim:
Location:
Page 26 of 41
January 22, 2016
Mayflower Red 310
6”x6”x3/8”
6" x 6" Cove Base with Bullnose (Q3565)
Kitchen #103
Shop Drawings: Submit drawings indicating tile patterns and locations as well as locations of
expansion and other joint types occurring in substrates. Submit tile samples for each type, color
and texture required, at least 12 inches square, mounted on durable backing, and showing grout.
Lay Out (Unless Otherwise Noted): Prepare lay out of tile work so as to align joints of floor,
base, wall tile and trim when pieces are of same size. Lay out so as to center tile fields in both
directions in each space or area, to minimize tile cutting and provide joints of uniform widths.
Provide lay out so as to minimize use of tile that are less than one-half tile in size
1. Locate expansion joints and other joint types to be sealant filled during installation of setting
material. Do not saw cut joints after tile has been installed. 2. Locate joints in tile surface directly
over joints that occur in concrete or other substrate material.
B. Protective Penetrating Sealer: Protect exposed surfaces of tile against adherence of mortar and
grout by applying a coating of specified non-discoloring clear resin penetrating type sealer at the
Project site. Provide care so as not to get any sealer on back and edges of tile.
Installation Standards: Provide installations complying with the following:
1. Tile Council of America (TCA) Handbook for Ceramic Tile Installation, latest edition.
2. ANSI A-108.1 Installation of Ceramic Tile
Refer to latest edition of Tile Council of America (TCA) "Handbook for Ceramic Tile
Installation", with modifications for West Coast installations by Ceramic Tile Institute,
"Installations and Performance Levels", as a guide to determine method of setting tile work.
***REFER TO TCA HANDBOOK TO SELECT APPROPRIATE SETTING MATERIALS
LISTED IN B, C, D, AND E, BELOW. ALSO REFER TO TCA HANDBOOK FOR EPOXY,
FURAN AND OTHER INSTALLATION METHODS AND MATERIALS***
09 51 23
Acoustical Tile Ceilings
Manufacturer:
USG Interiors, Inc.
Local Rep.
Pace Pickel, [email protected], 404-202-8792
Color:
White
ACT-1 - Kitchen Ceiling Tile
Product:
USG Sheetrock lay-in ceiling panels "ClimaPlus" 3270
vinyl faced washable 2' x 4' x 1/2" square edge tile
w/ 1" grid with white painted aluminum cap DXLA
Color:
White
ACT-2 – Typical Ceiling Tile
Product:
USG Mars "ClimaPlus"
2' x 2' x 3/4" reveal edge tile with standard 1" white grid
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Color:
Page 27 of 41
January 22, 2016
White
09 64 33
Engineered Wood Flooring – Refer to Finish Legend
Manufacturer:
Armstrong
WF-1 - Typical Plank
Product:
Performance Plus
Color:
To be Selected
Substrate:
Subcontractor shall approve substrate to assure substrate defects will not
telegraph through the finished floor.
Installation:
Install per manufacturer's recommendations.
Prepare substrate as
recommended and adhere using manufacture's adhesives appropriate to
concrete or wood subflooring substrate.
Layout/Installation: Position planks so the end seams are no closer than the width of the plank
being installed. Center planks in rooms / hallways so borders are not less
than half a plank. Cut edges shall always be installed against a wall.
Maintenance:
Hallmark NuOil; refer to manufacturer’s recommendations
Attic Stock:
Provide 5% of the area of each flooring type as attic stock to replace
damaged planks in the future.
Warranty:
5 year commercial finish, 10 year commercial structural warranty
Local Represent.:
Steve Howell, [email protected], 678-446-6313
09 64 53
Manufacturer:
Resilient Wood Flooring – Refer to Finish Legend
Karndean USA. 1-888-266-4343, www.karndean.com
VPF-1 - Typical Plank –
Locations:
Second and Third Level Corridors, Study/Exec #317
Product:
Van Gogh
Color:
VGW70T - Smoked Oak
Dimensions:
48" x 7"
Thickness:
1/8" (3mm) with 0.5 mm wear layer
Edge:
Square (non-beveled)
Substrate:
Installation:
Subcontractor shall approve substrate to assure substrate defects will not
telegraph through the finished floor.
Install per manufacturer's recommendations. Prepare substrate as
recommended and adhere using manufacture's adhesives appropriate to
concrete or wood subflooring substrate.
Layout/Installation: To achieve a random natural wood look, take planks and cut nominal
lengths to be used on the first course; example: 10", 40", 15", 25", 8", etc..
At the end of the first course, all cut planks remaining should be used on
the next course. Position planks so the end seams are no closer than the
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Protective coat:
Attic Stock:
Warranty:
Local Represent.:
Page 28 of 41
January 22, 2016
width of the plank being installed. Maintain this approach to staggering the
planks throughout the entire installation. Center planks in rooms / hallways
so borders are not less than half a plank. Cut edges shall always be
installed against a wall.
Quantum Guard HP
Provide 5% of the area of each flooring type as attic stock to replace
damaged planks in the future.
10 year commercial warranty
Laura Ann Wagerman, [email protected], (404) 3082142
09 65 13
Resilient Tile Flooring – Refer to Finish Legend
Vinyl Composition Tile: Through-pattern Vinyl Composition.
Tile must pass Flooring Radiant Panel Test with Class 1; pass Flame
Spread; pass N.B.S. Smoke Chamber Test with less than 450. Adhesive
recommended by manufacturer shall be used and conform to the tile flame
spread. Tile should be installed according to manufacturer instructions. Slip
resistance shall meet A.D.A. requirements. Adhesive and tile shall be
asbestos free.
Attic stock of two cartons of each VCT used shall be provided to owner at project completion.
VCT-1 - See Finish Schedule for locations
Product:
Striations
Color:
To be determined
Dimensions:
12" x 24" - laid in running bond pattern
Thickness:
1/8"
Warranty:
5 year commercial warranty
Attic Stock:
Provide 3% of the area this flooring type as attic stock to replace damaged
tile in the future.
VCT-2 – See Finish Schedule for locations
Product:
Standard Excelon Imperial Texture
Color:
Color and pattern shall extend through thickness of tile. To be selected
from manufacturers standard colors
Dimensions:
12" x 12" - laid in grid pattern
Thickness:
1/8"
Warranty:
5 year commercial warranty
09 65 13
Resilient Base – Refer to Finish Legend
Manufacturer:
Roppe Corporation, 1-800-537-9527, www.roppe.com
Product:
4" rubber cove base
Color:
#100 Black
Installation: Install per manufacturer's recom
09 65 19 Resilient Tile Flooring – Refer to Finish Legend
Manufacturer: Armstrong Commercial Flooring, 1-877-276-7876, www.Armstrong.com
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Installation:
Page 29 of 41
January 22, 2016
Install per manufacturer's recommendations. Provide molded outside
corners, interior corners to be job formed.
09 68 00
Carpet – Refer to Finish Legend
CPT-1 - Typical Carpet – Allowance = $30.00/SY
Locations:
Sleeping Rooms and Stairs
Manufacturer:
Local Source:
Construction:
Pile:
Collection:
Style#:
Color:
Layout Pattern:
Standard Backing:
Attic Stock:
09 77 20
Fiberglass Reinforced Plastic (WC-7) Wall Panels – Refer to Finish Legend
Wall panels at the Kitchen and Janitor Closets shall be USDA approved .090" textured
Fiberglass Reinforced Plastic (FRP) 48" x 120" wall liner panels mounted vertically above the
seamless flooring base. Provide matching colored vinyl molding at intersecting panel joints and
panel edges. Apply with 100% adhesive coverage directly to primed gypsum board partitions.
Paint walls epoxy above panels.
Basis of Design: Structoglas
Product:
Fiberglass Panels 0.09" Class C-77096
Color:
White
Provide stainless steel wall panels minimum 18" width around grease hood. See Drawings.
09 90 00
Painting and Coating
Surfaces to be painted shall be prepared and paint applied in strict accordance with
manufacturer's instructions and specifications. All new surfaces shall receive one prime coat
with a minimum of two finish coats. Apply additional coats when undercoats, stains, or other
imperfections show through final coat until paint film is of uniform finish, color and appearance.
Specific paint colors will be selected from specific manufacturer(s). If the Contractor elects to
use a manufacturer other than the manufacturer from which the Architect's selection was made, it
shall be the responsibility of the Contractor to provide color matches from the other
manufacturer(s), and to submit samples of the substitute colors for approval. Samples shall have
the same finish and number of coats as required for the actual work, and shall be on gyp. bd.
panels not less than 12" x 12".
Contractor shall submit two (2) samples of each paint color specified to the Architect prior to
commencing the work. Samples shall have the same finish and number of coats as required for
the actual work. All samples shall be 12" x 12". Contractor shall also provide a mock-up wall of
each wall color specified for Owner review.
Basis of Design:
Contact:
Benjamin Moore & Co. (no substitutes without approval of the Architect).
Randall J. Smith, 678-794-8176
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Exterior Paint Schedule
Exterior PVC and
Polyurethane trim
Primer
Stix Bonding Primer
Galvanized Steel and Aluminum (exposed lintel angles)
P-04 Super Spec HP Acrylic
Metal Primer
Page 30 of 41
January 22, 2016
Top Coat – Paint
631 Aura Waterborne Exterior
Satin House Paint
P-28 Super Spec HP Int/Ext
Acrylic Gloss Enamel*
Interior Paint Schedule
Gyp. Bd, walls & soffits
Primer
253 Super Spec Acrylic Latex
Primer Sealer
Top Coat – Paint
221 Regal Matte 100% Acrylic
Satin
Gyp. Bd, Ceilings
253 Super Spec Acrylic Latex
Primer Sealer
275 Super Spec Latex Flat Wall
Paint
Gyp. Bd, at Kitchen
253 Super Spec Acrylic Latex
Primer Sealer
P-42 Super Spec HP Waterborne
Polyamide Epoxy (2 coats min.)
Painted wood:
253 Super Spec Acrylic Latex
Primer Sealer
P-28 Super Spec HP Acrylic
Semi-Gloss Enamel
Ferrous metal at hollow metal doors/frames, handrails, ladders etc.:
P-06 Alkyd Metal Primer
P-28 Super Spec HP Int/Ext
Acrylic Semi-Gloss Enamel
Galvanized Steel and Aluminum (supply/returns/access panels)
P-04 Super Spec HP Acrylic
P-28 Super Spec HP Int/Ext
Metal Primer
Acrylic Semi-Gloss Enamel*
*Supply and return air grilles, plates, access panels, etc. occurring on walls or ceilings are to be
finished to match the surface on which they are located. Remove prior to painting and reinstall
so that paint does not bond these items to the walls.
Division 10: Specialties
10 11 16
Magnetic White Board – Refer to Finish Plans I1.1, I1.2, I1.3
Product:
Porcelain Magnetic White Markerboard with Aluminum Frame / Tray
www.usmarkerboard.com/Porcelain-Steel-Magnetic-Markerboards/8598
Locations / Sizes:
Study/Exec Room 318:
4' H x 10' W, Model PSM44A
Laundry Room 216
2’H x 3’ W, Model PSM23A
Mounting Height:
6'-8" to top
Frame type / finish: Painted 1 x 3 w/ routed edge to receive Homasote (by trim carpenter)
Source:
US Markerboard, 1-800-791-2946
10 11 23
Bulletin boards – Refer to Finish Plans I1.1, I1.2, I1.3
Product:
Homasote "DesignWall 550" Fire Resistant Fabric Panels
Manufacturer:
Homasote Company
Source:
Al Miller and Associates, 404-487-8997
Fire Rating:
Class A
Finish/Color:
Submit samples of available fabrics for Architect's approval
Locations / Sizes:
(1) Hall #114
4' H x 8' W
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Mounting Height:
Thickness:
Edge Trim:
Page 31 of 41
January 22, 2016
(1) Corridor at Lounge #218
4' H x 8' W
7'-2" to top
1/2"
Painted 1 x 3 w/ routed edge to receive Homasote (by trim carpenter)
Secure to wall with APA approved subfloor adhesive. Brace to wall for 24 hours minimum.
10 14 00
Signage and Graphics
Dimensional letters shall be Times New Roman:
Dimensional Dark Bronze anodized aluminum letters (exterior):
ΑΦ Letters at Front and Side Gable Pediment shall be 20" high x 1 1/2" thick.
Letters shall be back lit with LED rope light provided as part of the signage
Source: Bartlett Pair Architectural Signage, 770-554-3730
Interior Signage
Provided and installed by Owner's separate vendor. The following is for information only.
Mount all signs on wall adjacent to latch side of door, 60" above finished floor.
Font shall be "Garamond".
Provide 8" x 8" signs with at latch side of doors to "MEN" (2) and "WOMEN" (2).
Submit shop drawings of all signage and one sample sign (sample can be used in final
installation if approved).
10 28 13
Toilet Accessories
Basis of design: American Specialties Inc. See attached Bathroom Accessory Schedule and
Floor Plans for locations and quantities.
Locations:
A
Bathroom #108, #109
B
Women’s Bathroom #215, #314
C
Bathroom #213
D
Shower Areas #214A, #312A, #214C, #312C
E
Accessible Showers #214B, #312B
G
Janitor’s Closets #219, #318 and Kitchen #103
ITEM
HD
PTD
TTD1
TTD2
LSD
GB1
GB2
GB3
GB4
FND
PRODUCT
AUTOMATIC POWERED HAND DRYER
PAPER TOWEL DISPENSER
TOILET TISSUE DISPENSER
TOILET TISSUE DISPENSER
AUTOMATIC LIQUID SOAP DISPENSER
54" x 36" GRAB BAR
18" x 33" GRAB BAR
48” GRAB BAR
12” GRAB BAR
PARTITION MTD SANITARY NAPKIN DISP.
MODEL NO.
0185-93
9452
9030
0264-1A
20364
3856
3874
3801-48”
3801-12”
0472
LOCATION
A,
A, B, C
A,
B,C
A, B, C, D
A-C
E
E
A, B
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
SH-1
SH-2
RH
Page 32 of 41
January 22, 2016
SHOWER SEAT
SHOWER SEAT
ROBE / TOWEL HOOK
8206-R
8303
7301
E
C, D, E
SHOWER CURTAIN RODS
SHOWER CURTAIN HOOKS
SHOWER CURTAINS
MOP / BROOM RACK
1204 xLAR
1200-SHU (2 /FT. +1)
1200-V x LAR
8215-3
C, D, E
C, D, E
C, D, E
G
10 28 16
Locations:
Custom Sized Bathroom Mirrors
Bathroom #215, #314, #213; Restroom #108, Restroom #109 to have
specialty frame, product specification to be provided by architect
Frame:
Painted 1 x 3 w/ routed edge to receive Homasote (by trim carpenter)
Mirror Glazing:
Polished tempered glass with two coats of silver applied. Silver to
be hermetically sealed by electroplating with a heavy uniform
coating of copper. Back of mirror shall be finished and protected by
a thick coat of heavy waterproof painted. Edges of mirror shall have
vinyl tape all around that is covered by the frame.
Guarantee:
Mirror shall be guaranteed for 15 years against silver spoilage,
Size:
Mirrors shall extend from wall to wall (the full width of the vanity
and/or make-up counter) and from the top of the shelf or backsplash
to 7'-0" AFF.
10 44 00
Fire Extinguishers and Cabinets
Non-rated Recessed Cabinets (4 required)
Provide 5 lb. 3A-40B:C fire extinguishers mounted in fully recessed extinguisher cabinets in the
locations shown on the drawings. Cabinets shall be Larsen "Occult Series" O-2409 (requires 6
1/4" rough opening depth) with solid (no window) door with concealed hinge and a handle.
Door to be cold-rolled steel with white baked acrylic enamel finish, painted to match adjacent
wall surface. Install black, die cut "FIRE EXTINGUISHER" lettering vertically.
Fire rated Recessed Cabinets (4 required)
Cabinets shall be Larsen "Occult Series" FS O-2409 with the Fire-Rated Flame Shield option
(requires 6 7/8" rough opening depth) All other requirements shall be the same as the Non-rated
recessed cabinets.
Kitchen (1 required)
Provide 6 liter 2A-1B:C:K fire extinguishers surface mounted on manufacturer standard wall
brackets in the Kitchen.
Source: Larsen's Manufacturing Company, 1-800-527-7367
www.larsensmfg.com/fire_extinguishers/3part.html
10 55 00
Mail Package Drop Box
Location:
(1) Main Level
Product:
Full Service Curbside Delivery Vault
Manufacturer:
dVault Company Inc., www.dvault.com
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 33 of 41
January 22, 2016
Source:
U.S. Mail Supply, Inc., 1-800-571-0147, www.usmailsupply.com
Model:
DVCS0015
Material / Finish:
16 gauge steel / powder coated poly-hammer finish
Color:
Black
Size:
19" W x 19" D x 47.75" H
Weight:
100 lbs.
Mail and Packages are deposited through separate non-locking doors on the front. Mail door
provides access to incoming mail slot and outgoing mail cubbie.
Separate rear access doors for mail and packages – Provide thumb turn in lieu of keyed access.
Accepts packages up to 21"L x 12.5"W x 10"H.
U.S.P.S. approved, includes carrier service flag
10 57 23.13 Wire Closet and Utility Shelving
ClosetMaid white vinyl coated steel rod ventilated shelving/rod as manufactured by Carlson
International. Unless indicated otherwise on the drawings all shelving to be installed wall to
wall, with support hardware at 36" o.c. maximum. All shelves shall be "Super Slide" decking
(for linen) with "Super Slide" hang rod installed below where described below:
Sleeping Room Closets
Media Closet #116
T-Shirts #321
Janitor Closet #219, #319
Showers #214
Showers #313
Laundry Room 216:
Ritual #317
Closet #211
10 57 23.19
Locations:
Dbl. rod & shelf: (2) - 16" shelves and rod at 3'-5" & 6'-8" AFF
Single Curtain rod at Sleeping Room Closet openings (for student
furnished curtain)
(8) – Adjustable 18" shelves
(1) – 16" rod & shelf
(5) – Adjustable 16" shelves
(24) - 12”x12”Cubby Grid
(24) - 12”x12”Cubby Grid
Single rod & shelf – 36”w x16”d shelf and rod at 6’-8” AFF over
floor sink
(24) - 12”x12”Cubby Grid
(1) – 16" rod & shelf
Dbl. rod & shelf: (2) - 16" shelves and rod at 3'-5" & 6'-8" AFF
Wood Closet and Utility Shelving
Supply Closet 316 – 5 shelves high
Sign Design 314 – 5 shelves high
Product:
Manufacturer:
Bracket Model:
Standard Model:
Material / Finish:
Heavy Duty Shelf brackets and standards
Knape & Vogt
12” deep shelves - #187ANO12 (12 gauge) shelf brackets
16” deep shelves - #187ANO16 (12 gauge) shelf brackets
24” deep shelves - #187ANO24 (12 gauge) shelf brackets
#87 ANO (12 gauge) standards
Anochrome
Wood shelves to be ¾” thick primed MDF boards x width indicated
in the drawings.
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Location:
Product:
Manufacturer:
Size/Model No:
Mounting Height:
Material / finish:
Accessories:
Page 34 of 41
January 22, 2016
Supply Closet 316 – Hanging (1 bay)
Extra Heavy-Duty Round Closet Rod
Knape and Vogt, www.kv.com
1 1/16" diameter / 770-1 Series
6'-0" AFF
Chrome plated Steel
735 Tubing end support Flanges, Chrome Finish
1195 Heavy Duty Closet Rod Support, White Finish
10 81 00
Built-in Pest Control System
Provide "The Pestban Built-in Pest Control System" by Pestban, Inc. System consists of exterior
multi-service ports manifold (access for periodic pest treatments), solid ¼" thick polyethylene
carrier lines through the building, and ¼" thick perforated dispensing lines between studs (at
approximately 16" above floor, maximum runs of 50'). Service port manifold to be located
outside of Kitchen.
Dispensing lines to occur in all exterior walls on the Main Level and Basement, and in the
interior walls surrounding the Kitchen 103 and Pantry 101. System is installed before wall
insulation phase. Provide shop drawings noting locations of all components for approval.
Contact: Pestban, Inc. 770-592-1121 http://www.pestban.com/built-in-pest-contol-system.
Division 11: Equipment
11 40 00
Food Service Equipment
See Kitchen Consultant Drawings and Specifications. Provide shop drawings and manufacturer
literature / cut sheets for all supplied equipment. Shop drawings shall also indicate rough-ins and
attachments at all installations (including relocated existing equipment).
11 31 13
Kitchen Appliances
Provide and install Kitchen Appliances at House Directors Suite.
Undercabinet Refrigerator
Residential countertop microwave
11 31 23
Laundry Appliances
Provide and install Laundry Appliances at Laundry #216, and residential single stacked combo
unit at Kitchen #103. Provide up flow recessed dryer vent boxes for 4” dryer vent and lint trap –
Fantech model DBLT4, typical at each dryer connection. See Allowance no. 3
27” wide large capacity Front Loading commercial washing machine (1)
27” wide large capacity Front Loading commercial electric dryer (1)
27” wide combo stacked washer dryer (3)
Stack washers and dryers as indicated on drawings.
11 33 00
Retractable & Folding Ceiling and Attic Stairs
Provide and install Retractable & Folding Ceiling and Attic Stairs – Coordinate exact location
with roof structure and truss spacing.
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Manufacturer:
Location:
Product:
Page 35 of 41
January 22, 2016
Century Industries
Supply Closet #316
SAG-100
Division 12: Furnishings
12 23 00
Source:
Manufacturer:
Interior Shutters
Sarah Laurie, American Sun Control-Commercial Division, 404-374-4212
SWF Contract, 1-800-327-9798, www.swfcontract.com
Solid Color Blinds
Locations:
Second Level and Third Level Sleeping Rooms
House Directors Suite #210 and #212
Kitchen #103
Product:
Graber Lake Forest 2" Faux Wood Blinds
Slats:
Rigid UV stabilized flat PVC nominally 2” wide x .10” thick
with straight cut edges
Color:
Milky Way
Options:
Cordless Lift
Electro-zinc coated steel wand tilter
NoHoles Slats
Hold down brackets at doors and window and sidelights
Warranty:
Five-year limited warranty
http://www.swfcontract.com/pdf/data-sheets/DS-2Fauxwood.pdf
Mounting:
Typical Sleeping Room windows:
Blinds to be mounted inside window jamb with a single blind covering the
group of ganged windows/transoms (maximum width of 96")
Plantation Shutters
Manufacturer:
Locations:
Product:
Slats:
Peachtree Blinds of Atlanta, (770) 664-0027
Main Level public areas
Wood Shutters
Rigid UV stabilized flat PVC nominally 2” wide x .10” thick
with straight cut edges
Color:
Shutters to be custom painted to match adjacent window casing color.
Warranty:
Five-year limited warranty
http://www.peachtreeblinds.com/atlanta_plantation_shutters.htm
12 36 61.13 Cultured Marble Countertops – Alternate 2
Provide alternate price for Cultured Marble Countertops and integral bowls as follows:
¾” thick cast marble countertop with 4” high integral back splash and separate side splashes at
each side, with cut-outs for undermount lavatory bowls.
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 36 of 41
January 22, 2016
Colors:
Color to be selected
Location:
Women’s Restroom #215, #314 CM – 1
12 36 61 .19
Product:
Quartz Composite Countertops – Refer to Finish Plans I1.1, I1.2, I1.3
Silestone Quartz sheets manufactured by Cosentino USA (866) 268-6837
www.silestoneusa.com or approved equal
Composition:
quartz aggregate, resin, and color pigments formed into flat slabs with
anti-microbial protection integral to sheet.
Thickness:
3/4" – provide built up 1 1/2" edge at QTZ-1 only
Colors:
QTZ – 1
QTZ – 2
Doracus (black with gold veining)
Tao (solid black)
Living Room 112 Credenza
Dining/Chapter 119 Buffet
Serving 104
Sister Kitchen 118 Counter
Restrooms 108, 109
Bathrooms 215 & 313
Thresholds at showers
*
QTZ – 1
QTZ – 1
QTZ – 1
QTZ – 2
QTZ – 2
QTZ – 2
QTZ – 2
*Thresholds at cased openings into showers to be 1 1/2" thick x the length of the opening. Edges
to be beveled with 1/4" high x 1/2" wide bevels. Set top of threshold 1/2" above tile to contain
water and to meet ADA requirements for roll in sho
Bowl at Restrooms 108, 109 and Bathrooms 215 & 314 to be Kohler Ladena Under-Mount
Bathroom Sink K-2214 in white
Local Rep:
Phil Devore 832-451-8134, [email protected]
Provide 4” tall backsplash and side splash at vanities. No substrate is required to support the
countertops.
12 48 13
Entrance Mats
Source:
Hinton Sales, 770-326-6455
Manufacturer: Anderson Company, 800-241-4696
http://www.andersenco.com/marketing/tac/commercial/2009.html
Submit manufacturer's data and sample for Architect to confirm color selection.
Typical Mats
Product:
Color:
Location/Size:
WaterHog Classic - 100% solution died polypropylene
on a rubber backing with rubber border
#152 Dark Brown
Outside Doors E101, E102, E103, and E104
4' x 6'
Inside Doors E101, E102, E103, and E104
4' x 6'
Inside Exist Stair doors S101 & S102
3’ x 4’
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Inside Kitchen door E105
Inside Balcony doors E201
Inside of Kitchen door E103
Page 37 of 41
January 22, 2016
3’ x 4’
3’ x 4’
3’ x 4’
12 93 13
Bicycle Racks
Provide "black" powder coated bike rack by Belson Outdoors (800) 323-5664 www.belson.com.
Bike rack shall consist of one 4-bike 72 5/8" L Model GRR-B-4-SF-P. Secure to concrete
sidewalk with Concrete Anchor Kits. Assembled bike rack dimensions: 72 5/8"L x 12"D.
Division 13: Special Construction-No Sections
Division 14: Conveying Systems
14 24 23
Hydraulic Elevator
Manufacturer:
ThyssenKrupp (or equivalent from Otis or Schindler)
Model:
AMEE 21 – Plan 1, 3-stage Twinpost Telescopic
Capacity:
2,100 lbs.
Speed:
100 FPM
Net Travel:
25’-8”
Stops:
Three Stops: 1 - Main Level, 2-Second Level, 3- Third Level
Hoistway Entrances: 3'-0" x 7'-0" - front and rear single slide, side opening entrance doors.
Painted finish.
Sills:
Bronze
Cab / Ceiling Height: 7'-11" / 7'-4"
Clear Inside Dim.:
5' - 8'' wide x 4’ - 3'' deep
Min. Hoistway:
7’-8” wide x 5' - 9'' deep
Cab Finishes:
Rear and side panels – Formica 7182-58 Dune Wood (Standard
Finish)
Cab fronts with swing return - stainless steel #4 finish
Car doors - stainless steel #4 finish.
Tamper proof buttons.
Suspended ceiling-lay-in translucent ceiling with fluorescent lighting.
Flooring - FC-10 (See Finish Legend on I1.1)
Handrails at sides & rear of cab to be contin. 2" bar stain. steel #4
finish.
Standard signal fixtures and car riding lantern
Hoistway doors & frames-See Section 9900 for paint schedule colors
Elevator Maintenance Proposal shall be submitted with the subcontractor’s proposal.
Submit manufacturer's technical data and shop drawings in sufficient detail and in accordance
with the design concept, showing work required by other trades and in compliance with ASME
/ANSI A17.1 Safety Code for Elevators and Georgia Accessibility Code and the Americans with
Disabilities Act.
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 38 of 41
January 22, 2016
Division 15: Mechanical
See MEP Drawings/Specs
Division 16: Electrical
See MEP Drawings/Specs
16140 Wiring Devices
Wall switches shall be mounted at 48" above finish floor to centerline of switch unless noted
otherwise. Where outlets occur in areas with wood base (see finish schedule for locations), they
shall be mounted horizontally and centered vertically in the base. Wall outlets in other areas
shall be mounted at 12" above finish floor to centerline of outlet unless noted otherwise.
Use multi-gang cover plates where multiple switches or outlets are shown. Where multi-gang
boxes are not feasible (i.e. computer, telephone outlets with electrical outlets) align boxes
horizontally and space boxes equally.
Devices shall be white. Cover plates (including phone and computer jacks) shall be white nylon
typical.
16 74 00 Door Bell System
See Low voltage drawings
Division 21: Fire Suppression
21 13 00
Sprinkler System
Provide and install a fully automatic fire sprinkler system in conformance with NFPA 13.
Division 22: Plumbing
See the Attached Design Development Scope of Work document
22 06 40
Plumbing Fixture Schedule
Plumbing fixtures shall be standard white finish. All faucets and shower trims shall be standard
brushed chrome finish. Floor mounted toilets are located at the Second and Third Level common
bathrooms (215, 314). Floor mounted toilets are located on the Main Level in Bathroom (108,
109, 213).
Product:
Water Closet, ADA
Water Closet
Undercounter Lavatory
Restroom faucets
Service Sink, 24"x24"
Laundry Tub
Floor Sink at Laundry
Sink at Sign Painting
Faucet at Sign Painting
Manufacturer
Kohler
Kohler
Kohler
Kohler
Fiat
Mustee
Fiat
Mustee
Kohler
Model No.
K-4368 w/ open front seat
K-4350 w/ open front seat
K-2211 w/ grid strainer
K-13460-CP
TSBC-1610, Faucet #830-AA
19 CFT Utilitub Combo
36EFS
25
K-7779-K-CP w/ K-16012-4 lever handles
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Faucet at House Dir. Bath 213
Shower Pan at Bath 213
Showers, ADA
Showers
Page 39 of 41
January 22, 2016
Kohler
Fiat
American Standard
American Standard
K-7779-K-CP w/ K-16012-4 lever handles
36WL molded
1662.213 FloWise Commercial Shower
T385.501 Reliant 3 Shower Trim
Division 23: HVAC
See the Attached Design Development Scope of Work document
Division 26: Electrical
See the Attached Design Development Scope of Work document
26 27 26 Wiring Devices
Wall switches shall be mounted at 48" above finish floor to centerline of switch unless noted
otherwise. Where outlets occur in areas with wood base (see finish schedule for locations), they
shall be mounted horizontally and centered vertically in the base. Wall outlets in other areas
shall be mounted at 12" above finish floor to centerline of outlet unless noted otherwise.
Use multi-gang cover plates where multiple switches or outlets are shown. Where multi-gang
boxes are not feasible (i.e. computer, telephone outlets with electrical outlets) align boxes
horizontally and space boxes equally.
Devices shall be White. Cover plates (including phone and computer jacks) shall be black nylon,
typical.
26 27 73
Door Bell System
Provide and Install Doorbell push button at Front Entry Door E101
Chime Locations:
Living #112 and Lounge #218
Secondary push button location 1
Chime Locations:
Balcony outside of Lounge #218 – Door E201
Lounge #218
Secondary push button location 2
Chime Locations:
Service Yard outside Kitchen Corridor #102 – Door E105
Kitchen #103
Product:
Manufacturer:
Model:
Material / Finish:
Wired Push Button and Recessed Electronic Chime with 16 volt
transformer
NuTone
PB15LBR Push Button / LA174WH Recessed Chime
Oil Rubbed Bronze Push Button
Chime Louvered Grille painted to match wall color
Division 28: Electronic Safety and Security
28 13 00
Access Control
Access control system to be web based. Provide the eMerge Essential Plus ES-1M + ES-1DLx2
access control system for 3 doors. Locate cabinet where indicated on the drawings. Provide
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 40 of 41
January 22, 2016
HID iclass SE proximity card readers at locations indicated on drawings. Provide 50 extra cards,
HID iclass RP Series. Include training for all necessary personnel. For pricing and installation,
contact Horizon Electronic Security; 402 Swanson Drive, Suite 101, Lawrenceville, GA 30043;
www.horizonsecurity.net ; Attention Marc Singletary, (770)338-9449, [email protected]
28 23 00
Video Surveillance
Video surveillance system to be web based. Provide the EverFocus EHN3340 Outdoor IR Dome
Cameras at locations indicated on drawings. Provide the EverFocus ENVR8304D-8CH Network
Video Recorder. Locate video recorder where indicated on drawings. Include training for all
necessary personnel. For pricing and installation, contact Horizon Electronic Security; 402
Swanson Drive, Suite 101, Lawrenceville, GA 30043; www.horizonsecurity.net ; Attention Marc
Singletary, (770)338-9449, [email protected] .
Division 31: Earthwork
31 23 00
Excavation and Fill
A Geotechnical report for testing and evaluation of existing site soils will be provided
31 31 00
Soil Treatment
Soil treatment for subterranean termites shall be applied by a state licensed pest control operator.
Provide the Owner with a renewable one year Termite Bond/Warranty as required by the State of
Georgia.
Division 32: Exterior Improvements
32 13 16
Decorative Concrete Paving
Decorative Exposed Aggregate Concrete Paving
Locations: Front Porch (between brick banding), Front Outdoor Dining Patio (between brick
banding), Exterior Stairs and lower landing leading to Brittain Drive.
Exposed aggregate finish with integral tint. Concrete mix shall be by Thomas Concrete 770431-3313, mix number 301-P with #C-12 “Mesa Beige” Tint by L.M. Scofield Company added
at plant. Mix 301-P is made up of standard 3000 p.s.i. residential concrete pump mix, with
granite #57 stone, a blend of granite and natural sand, Type I cement, Class F flash, water
reducing agents, and air entrainment admixture. After concrete is poured but before it has set up,
seed with additional aggregate, and spray with retardant. After concrete has set to walkable
firmness, hose off top slurry layer of cement to expose aggregate. Acid wash and apply a clear
sealer. Pour small sample for architect's approval.
32 31 00
Ornamental Metal Gate
Ornamental Metal Gates shall be galvanized steel powder coated Monumental Iron Works Fence
System by Master-Halco 404-766-0063. Finish of all components to be "Dark Bronze" or
"Black". Submit product samples for color selection. Submit shop drawings of all fences and
gates for Architect's approval.
Addendum #2 Specifications for
Alpha Phi Sorority House
Project No. 1030
Page 41 of 41
January 22, 2016
3’-6” x 6'-0" Gate G1 at Mechanical Yard:
Estate Fence – Style "B"
02820 Ornamental Metal Picket Fence/Gates and Exterior Guard Rail
Ornamental Metal Picket Fence / Gates shall be galvanized steel powder coated Monumental
Iron Works Fence System by Master-Halco 404-766-0063. Finish of all components to be "Dark
Bronze" or "Black". Submit product samples for color selection. Submit shop drawings of all
fences and gates for Architect's approval.
3'-6" Guardrail at open side of the stair from the parking lot at the back yard:
Imperial Fence – Style "B" with 3 horizontal rails
Pickets to be 3/4" 16 GA square pickets (4"maximum opening between pickets)
Rails to be 1 1/2" x 1 3/8" 11 gauge 'U' channels
Posts to be 2 1/2" 14 GA posts cored into concrete retaining wall w/ "Flat Style" Post Cap (6'
maximum o.c.)
32 80 00
Irrigation
See Landscape allowance
32 90 00
Planting
See Landscape allowance
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project