Home Automation Products 16 - Marshall E. Campbell • Distribution

Home Automation Products 16 - Marshall E. Campbell • Distribution
DECORA HOME CONTROLS (DHC)
®
Residential Grade Network Integrity Products
DHC Network Integrity Products U R
4.77 (121.2)
3.08 (78.1)
1.64
(41.7)
2.69 (68.4)
4.12 (104.7)
Home Automation Products
HCA02-10E
1.73 (43.9)
DESCRIPTION
CAT. NO.
System Amplifier/Coupler/Repeater with Built-in Test Signal Generator—Performs a variety of
functions to ensure outstanding DHC system performance and reliability. Couples transmitter (programmer and controller) signals generated on the 120V leg where the transmitter
draws power onto the other leg in a 120/240V single-phase 3-wire residential wiring system. The HCA02-10E also amplifies and repeats command signals to maintain proper signal strength through the DHC system. Green pilot light indicates unit has power. Lamp will
indicate when signal is being transmitted. Features Intellisense™ Technology to help
ensure top performance even when noise is present on the AC powerline. The error lamp
indicates the Intellisense feature is activated. The unit provides convenient test signal
transmission for easy signal strength verification at individual DHC module locations using
Leviton’s Cat. No. 6386 Signal Strength Indicator.
The HCA02-10E should be installed at the main panel on its own dedicated 15A breaker in
accordance with NEC requirements. The HCA02-10E cannot be used in a 3-phase system.
HCA02-10E
Note: A Cat. No. HCA02-10E System Amplifier must be installed in all panels in every DHC installation
to ensure adequate signal strength.
Signal Bridge/Passive System Coupler—Couples the DHC command signal onto the 120V
legs of the power system to ensure sufficient command signal strength throughout the
DHC network. (NOTE: 6299 should NOT be installed in the same panel as HCA02-10E).
Rated: 120/240V 60Hz AC only.
Signal Attenuator, 2-Phase—Attenuates “(knocks down”) external noise and signal levels
entering the DHC network. The 6285 can be used to block interference from appliances,
electronic ballasts and home electronics to ensure top performance from DHC network.
Also used to block signal leakage (attenuation) caused by capacitive filters and electronic
power supplies.
Rated: 2-Phase 120/240V & 120/208V 60Hz AC only.
Multi-Phase Blocking Coupler—The 6284 is installed between the incoming electrical service
and the service panel in apartment buildings, condominiums, attached-unit dwellings and
homes sharing the same side of the electrical transformer. Keeps extraneous electronic noise
and signals from entering or leaving the DHC network.
Rated: 120V, 120/240V & 120/208V 60Hz AC—Max. 200 Amp panel.
6285
6284
1.38
(35.2)
6299
SPECIFICATIONS AND FEATURES
• Cat. No. HCA02-10E System Amplifier/
Coupler/Repeater must be installed in all DHC
installations to ensure adequate signal strength.
• Cat. Nos. 6284 and 6285 are used to stop extraneous noise and signals from degrading DHC network
operation
• Backed by a Limited Two-Year Warranty
TESTING AND CODE COMPLIANCE
• UL Listed (File #E-66800)
• CSA Certified (File #LR3413)
• UL 244A Tested (and others where applicable)
MATERIAL CHARACTERISTICS
Engineering Thermoplasti UL-94, V2 Rating
Operating Temperature: 32°F to 130°FMATERIAL
CHARACTERISTICS
K
16
6299
To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com