GAT Info 6800 Information Terminal

GAT Info 6800 Information Terminal
GAT Info 6800
Information Terminal
Application
The GAT Info 6800 is a stylish terminal for displaying visitor information
in leisure facilities such as swimming pools, spas and gyms. Identification
at the terminal is by contact-free RFID data carrier (Radio Frequency
Identification).
The Information Terminal is operated by four function keys and a colour
touch display. The clear user interface guides the user through the various,
well-structured levels. The different versions (see order information) give
technological flexibility.
Function description
Order information
The GAT Info 6800 is used to indicate visitor information for a short period
Description
on the display by holding the data carrier over the round scan field. Visitor
information can be locker number in use, credit balance, visit duration etc.
Further functions:
•Illuminated, round scan field
•Language selection via user interface
•Secure data transmission between reader and data carrier
•Security via mechanical lock
•Plug & Play installation
GAT Info 6800 B
PartNo.
653481
Information terminal with colour touch display and
contact-free reader for LEGIC ® data carriers
GAT Info 6800 ISO
---
Information terminal with colour touch display and
contact-free reader for ISO 15693 data carriers
GAT Info 6800 F
---
Information terminal with colour touch display and
contact-free reader for MIFARE® data carriers
Accessories
Description
GAT Info 6800 Manual
PartNo.
---
Operating and configuration instructions
GAT Holder 6050
654179
For mounting the GAT Info 6800 on a pillar or other
applications
www.gantner.com
Valid as from September 25 th 2008 • Technical data subject to modifications without notice!
DB_GAT-INFO6800_ EN _11.indd • PartNo.: 679388
1
Technical data
Nominal voltage:
12/24 VDC (SELV - safety extra-low
voltage)
Connection terminals:
0.5 to 1.5 mm2
Housing material:
Plastic (PC-ABS), halogen-free
Permitted input voltage:
10 to 28 VDC
Dimensions:
197 x 199 x 79 mm
Aver. power consumption:
12 W
Permitted ambient temperature: -10 to +55°C
Data storage:
Internal flash memory for configuring
and booking memory, data preser­
vation min. 10 years
Storage temperature:
-20 to +70°C
Relative humidity:
20 to 80%, non-condensing
IP 54
Internal clock:
Data preservation approx. 5 years
(battery)
Protection type:
Protection class:
III
Reader type:
See order information
Weight:
0.9 kg
Control elements:
-4 function keys
-RFID reader
-Touch display
Environment class
based on VDS 2110:
II (conditions in indoor areas)
Display elements:
-Colour touch display 5.7”,
resolution 320 x 240 pixels,
visible area 118 x 88 mm
-RFID reader (illuminated)
-Acoustic signal
Host interface:
Ethernet 10/100 Mbit/s and RS 485
Dimensions
1. Touch display
4
199 mm
1
5
2. Function keys
3. Illuminated, round scan field
4. Mounting frame
2
5. Display unit
3
79 mm
197 mm
Typical application
GAT Info 6800
Power supply
Network
2
i
Valid as from September 25 th 2008 • Technical data subject to modifications without notice!
DB_GAT-INFO6800_ EN _11.indd • PartNo.: 679388
www.gantner.com
Mounting and installation instructions
The mounting frame is secured by screws to the wall or the GAT Holder
Required mounting space
6050. Recommended mounting height: Top edge of device 1.3 m. Please
On securing the mounting frame please ensure the specified clearances
use the supplied drilling template when mounting the device.
are observed to allow for removal and locking.
Wall mounting
Cables can be flush (1) or surface-mounted (2).
When surface mounting please check whether the cables can still be
inserted once the frame has been mounted, otherwise run the cables
65.0 mm
through the cable lead-ins prior to securing.
118 mm
Cable duct for
surface-mounting
m
Cable duct for
surface-mounting
m
40 mm
5
Reserve
17.0 mm
2.5 mm
Ø
Recommended
mounting height 1.14 m
2
101 mm
min. 70.0 mm
1
2
Back box
Back box
116 mm
Mounting frame
Terminal connector with safety cap
max. 20.0 mm
Mounting the display unit
Once the connecting cables are wired up, the display unit is fixed onto the
mounting frame and secured with the built-in mechanical lock.
3.
Cable duct for
surface-mounting
Back box
Back box
Mounting frame
2.
Cable duct for
surface-mounting
Cable duct for
surface-mounting
Back box
Mounting frame
Remove Safety Cap
Back box
1.
4.
Instructions:
1. Only remove the terminal connector safety cap shortly before mounting
the display unit.
2. Rest the display unit with its top edge on the mounting frame and
swing down.
3. Push down the display unit until it clicks into the mounting frame.
4. Lock the terminal with the key and keep it in a safe place!
5. Once mounting is complete, the protective film can be removed.
www.gantner.com
Valid as from September 25 th 2008 • Technical data subject to modifications without notice!
DB_GAT-INFO6800_ EN _11.indd • PartNo.: 679388
3
Electrical connections
TCP/IP with external power supply
GAT Info 6800
TCP/IP
B
A
GND
VOut+
Mains power
Power supply unit
e.g. GAT Power Supply SP014/1
RS 485 with power supply via interface converter
0V24
B
A
+24 VDC
RS 232/USB
to PC/server
COM
Mains power
Interface converter
ISK 200
Network
RS 485 bus connection or Ethernet.
Attention: The two interfaces must not be operated at the same time!
When using RS 485 bus connection only connect the signal lines A and B.
Power supply
DC supply (see technical data), e.g. via GANTNER GAT Power Supply
SP014/1 or via the interface converter ISK 200. The two screw terminals
“VIN +“ are directly connected with each other internally. The power input
is protected against reverse-polarity.
Safety instructions
Recommended cables
Ethernet: min. CAT 5 (STP) for 100 MBit
RS 485: min. CAT 5 (STP), power supply via 2 wire-pairs
- This device must be installed by qualified personnel only.
- The applicable safety and accident prevention regulations
must be observed.
- Safety devices must not be removed.
- Please observe the technical data of the device specified
on the data sheet.
- The device must be disconnected from the power supply
prior to installation, assembly or dismantling.
4
Valid as from September 25 th 2008 • Technical data subject to modifications without notice!
DB_GAT-INFO6800_ EN _11.indd • PartNo.: 679388
www.gantner.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising