Data Sheet IQ251 Controller IQ251 CONTROLLER Description Features The IQ251 is a large capacity controller designed for the control of all types of building plant. It can provide up to 128 I/O points by connecting 8 I/O modules in any combination. The range of I/O modules comprises an 8 analogue plus 8 digital input module, an 8 analogue output module, and an 8 digital output module. Trend accessory modules may be connected to the input/output channels to provide greater I/O flexibility. They enable the IQ251 to provide sufficient capability for more complex strategies. It can operate either as a stand alone device or as part of a Building Management System. An optional Network Display Panel can be fitted on the front cover, or remotely. It provides access to all IQ controllers on a single or multi-Lan system via a node controller integrated within the IQ251. The IQ251 also provides the ability to connect any Trend supervisor or Engineering Tool to the network without the need for a separate node controller. • • • • • • • • • • • 1 second cycle time. Optional integral Network Display Panel. Access to entire network via local supervisor connection. Facility for mounting an additional node controller. High capacity DDC with PID control loops. Stand alone or integrated system operation. Up to 8 input/output modules for optimum configuration. Up to 96 logs. Up to 1000 values per log. Compatible with IQ151+ data files. Flexible I/O combinations main ac supply Physical 440 mm (17.32”) network display panel (optional) I/O modules 13 # T X R X auxiliary node knockout O N A D D R E S S 175 mm (6.9”) I/O modules network LED indicators connector supervisor RS232/modem (for auxiliary node) network address/baud 550 mm (21.7”) IQ251 Controller Data Sheet TA102315 Issue 3/A 24/7/02 1 IQ251 Data Sheet FUNCTIONALITY The IQ Controller’s functionality can be divided into three sections, strategy, firmware, and hardware. STRATEGY Module Type The strategy processes inputs according to a set of instructions and then outputs signals which can be used to control plant. Configuration: The IQ251 uses the standard IQ configuration mode which enables configuration via the network, or via the supervisor port. SET can be used to create a strategy data file (.IQ2) which can then be downloaded to the controller and subsequently uploaded for backup purposes if connected to the controller directly or via the network. PowerTool can be used to upload and download IQ2 files if connected via a modem. Modules: The strategy consists of a number of individual functional blocks known as configuration modules. These blocks can be linked in various combinations to enable plant to be controlled in accordance with the building’s requirements. The table lists the different types of configuration modules and the number of each type available with IQ251. Number Sensor 96 Sensor type Loop Module Type Number Critical Alarm 4 20 Alarm Histor y 20 32 IC Comms 16 Function 240 Digital Inputs 96 Logic 240 Fast Sequence 8 Driver 64 Zone 5 Knob 60 Schedule 32 Switch 60 Calendar 20 Sensor log 96 User Password 6 Sequence step 560 Sequence time Analogue Nodes 510 Digital Nodes Display 400 Directory 80 Page 80 Group 10 Route 50 Destination 7 New Alarm Log 300 1s 1012 Full details of the modules are given in the IQ Configuration Manual and Addendum. The IQ251 contains the normal IQ2 features as described in IQ Configuration Manual Addendum: Engineers Journal (J), I/O Summary (i/o) Loader Issue (R(c),’c’ lower case), Serial Number (R(s), ‘s’ lower case), Supply Frequency Option, Enhanced Logging, Module position, and Strategy Cleardown. External Channels: Because the I/O modules may be fitted in any combination in any of the 8 I/O slots, the channel numbers must be carefully identified. In configuration mode the IQ251 identifies the external channel numbers corresponding to the module number (in the case of sensors or digital inputs) or output channel number (in the case of drivers). Sensor Channels The sensor and digital input modules, and the output channels specified in the driver modules are related to the external channels as shown in the table: Digital Input Channels Driver Channels Sensor Number External Channel Dig. Input Number External Channel Output Channel External Channel S1 to S8 AA1 to AA8 I1 to I8 AD1 to AD8 1 to 8 E1 to E8 S9 to S16 BA1 to BA8 I9 to I16 BD1 to BD8 9 to 16 F1 to F8 S17 to S24 CA1 to CA8 I17 to I24 CD1 to CD8 17 to 24 G1 to G8 S25 to S32 DA1 to DA8 I25 to I32 DD1 to DD8 25 to 32 H1 to H8 S33 to S48 internal only I33 to I48 internal only 33 to 48 dummy channels A1 to A8 S49 to S56 EA1 to EA8 I49 to I56 ED1 to ED8 49 to 56 S57 to S64 FA1 to FA8 I57 to I64 FD1 to FD8 57 to 64 B1 to B8 S65 to S72 GA1 to GA8 I65 to I72 GD1 to GD8 65 to 72 C1 to C8 S73 to S80 HA1 to HA8 I73 to I80 HD1 to HD8 73 to 80 D1 to D8 S81 to S96 internal only I81 to I96 internal only 81 to 96 dummy channels The external channels are referenced as follows: [module position],[analogue(A) or digital(D) - input module only],[channel number] module position A E B F C G D e.g. 2 BA1 BD1 F1 A7 GD8 13 # H position B, Analogue input, channel 1 position B, Digital input, channel 1 position F, output channel 1 position A, output channel 7 position G, Digital input, channel 8 IQ251 Controller Data Sheet TA102315 Issue 3/A 24/7/02 Data Sheet IQ251 FIRMWARE Communications: When operating as part of a Building Management System, the IQ251 will be connected to other devices via the Trend Network. This means that information within the IQ251 can be accessed using one of the Trend supervisor programs, or passed to other Trend IQ controllers using inter-controller communications, enabling the sharing of information across the whole system. When connected to the network the controller can use up to 3 different addresses. One address is for the controller itself (set by front panel switch) the second and third are optional, and are for the locally connected supervisor (supervisor port address) and for an integral NDP (ndp port address). Thus both local supervisor and NDP have their own network addresses when connected to the network via the controller. The controller’s address is set by a switch, and the address for the local supervisor and NDP are set up in the strategy configuration (address module). Battery Status: The IQ251 has a battery status checking circuit that checks the battery on power up and thereafter every midnight and sets byte 506 bit 0 if the voltage has falls below a threshold value. This bit being set indicates that the battery needs to be changed. It should be used within the strategy to generate an alarm (e.g. critical alarm). The battery should be changed after the first indication. The battery will have a typical life of 10 years at 20 °C (68 °F). It is recommended that the battery is replaced every 5 years. Address/Baud rate switch: The address on the Lan is set by poles 1 to 7 in range 1, 4 to 9, 11 to 119 and must be unique on the Lan. The baud rate is set by poles 8 to 10 in the range 1k2, 9k6, 19k2 and must match the other nodes on the Lan. The address/baud rate switch may also be used to perform a strategy cleardown; this is done by setting all the address/baud rate poles to zero before power up (see Installation Instructions, TG103483 sheet 4 and IQ Configuration Manual Addendum). For this reason the address should normally be set non-zero. Battery Backup: Details about the strategy configuration, time and date, and logged data are stored in RAM. A plug-in lithium cell provides power to maintain the data in the event of power failure, or the controller being switched off. Auxiliary Supply: There is a 24 Vdc auxiliary supply provided on the power supply board to power external relay modules, sensors, external NDP etc. It is thermally protected and can supply a maximum of 500 mA. This will normally be available, but if the IQ251 has a full complement of I/O modules with integral NDP, and an integral comms node fitted the amount of auxiliary power available for other purposes will have to be calculated. The 24 Vdc supply in the IQ251 has 2100 mA available after deduction of current required for main board and network. This has to supply I/O modules, integral node, integral NDP, and the 24 Vdc auxiliary supply. These loads can be calculated as follows: 2 1 0 0 m A 7 5 m A o p tio n a l v a r ia b le HARDWARE Unit: The IQ251 has a metal chassis and a front cover consisting of a plastic fascia on a metal frame. The I/O modules are of aluminium extrusion. The I/O modules are fitted to the controller by snapping off a section in the cover and removing the relevant side plate. The module connector then slides into a socket on the controller. There is an option to fit a 16 terminal earthing bar below each I/O module for cable screens (Part/LA102359K). Cable access is via holes in the rear plate, or from top or bottom, cables can be run down the central column behind the controller board. Cleats are fitted to the rear plate to facilitate cable fixing. There is a 25 Way D type knockout on the bottom of the front panel for RS232 connection to an auxiliary node, and a circular knockout for M20 gland or grommet for internetwork, PSTN, ISDN or Lon cables. If required the IQ251 can be fitted in an IP55 metal enclosure (ENCLS). Connectors: Two part connectors are used throughout to facilitate wiring. A busbar is provided for screen termination. Power: 230 Vac 50/60 Hz, 24 Vac 50/60 Hz, or 24 Vdc. Fusing: The controller has no replaceable fuses; protection is provided by means of a self-resetting thermally protected transformer. The 24 V ac or dc version has a solid state multifuse. The I/O modules are also individually protected against short circuits. Indicators: LED indicators for receive and transmit network current flow (RX, TX) and network OK ( ), also for power ( ), all I/O channels ( ), and watchdog ( ). See specification section for details. Network: The network terminals facilitate connection of 2 or 4 wire cables. The standard Trend node features are included (TX, RX, and network OK, , indicators, bypass relay, and network alarm generation). There is also the facility for connection of a supervisor and integral network display panel to the network via the controller without the need for additional node controllers. Note that the IQ251 does not have a balanced line transmitter like other IQ2 series controllers and this may result in reduced network resilience. Balanced transmission can be achieved with the use of a BLT (Balanced Line Transmitter). IQ251 Controller Data Sheet TA102315 Issue 3/A 24/7/02 ( e .g . 2 5 0 ) o p tio n a l 5 0 0 m A ( m a x im u m ) N D P I/O n o d e A U X Input module 8 digital inputs @ 8 mA per channel 8 analogue inputs @ 20 mA per channel (thermistor and voltage inputs can be ignored) Max total for whole I/O module = (8x8)+(20x8) = 224 mA Output module 8 analogue outputs @ 20 mA per channel Max total for whole board = 20x8 = 160 mA 8 digital outputs @ 24 mA per channel Max total for whole I/O module = 24x8 = 192 mA Integral NDP= 75 mA Integral Node (e.g. TMN) = 250 mA. (For consumption of other nodes see the respective data sheet). For example: IQ251 with 4 input I/O modules, 2 digital output I/O modules, 2 analogue output I/O modules, an integral NDP, and an MNC. How much current is available from the auxiliary supply? Current consumed: 4 input I/O modules (all analogs are current) 4 x 224 =896 mA 2 digital output I/O modules 2 x 192 mA=384 mA 2 analogue output I/O modules (at max). 2 x 160 mA=320 mA 1 NDP 75 mA 1 TMN 250 mA Total 1925 mA Current available: 2100 - 1925 =175 mA 3 IQ251 Data Sheet HARDWARE (continued) I/O modules: The IQ251 has a range of I/O modules which may be fitted in any combination in the 8 I/O slots. The range comprises an 8 analogue and 8 digital input module (EIN), an 8 analogue output module (EAO), and an 8 digital output module (EDO). Inputs: The input channel combination is dependent on the number of input modules fitted. Each EIN module provides 8 analogue, and 8 digital inputs. Analogue Input (8 identical channels) 24V 8 8 C 24V 100K 10K IN 1 IN 4K7 100K 250R 27K 5V Digital Input (8 identical channels) Yellow 6 0V 100K C 0V Externally powered current sensor 0V Outputs: The output channel combination is dependent on the output modules fitted. There are two different modules; the EDO which provides 8 digital outputs, and the EAO which provides 8 analogue voltage outputs. A Trend 2VID interface module can be used in conjunction with 2 analogue voltage outputs to provide 2 analogue current outputs. Digital Output (8 identical channels) ON Analogue Voltage Output (8 identical channels) +24 N/C N/O C 22R Auto OFF Digital outputs have manual override facilities as indicated above. 3K9 100R Warning: High voltage may be present. Isolate elsewhere. OUT COM 0V Yellow 0V Link Headers: A range of link headers is available to enable the input channels to accept a wider range of inputs: LKE/5V Provide 5V, 20 mA supply Provides 10 mA supply (e.g. for potentiometer) IQ 2 5 x 1 0 0 K 1 0 0 K LKE/10mA IQ 2 5 x 2 5 0 R L K E /1 0 m A 2 0 0 R 5 V R E G 1 2 5 R If the input device is 100 Ω to 1000 Ω, the analogue input will be 1 V to 10 V. L K E /5 V C IN 0 V IN C 5 V S e n s o r LKE/15V Provides 15 V, 20 mA supply IQ 2 5 x 1 0 0 K 1 0 0 K LKE/DI A n in Converts analogue input to digital input. 2 5 0 R IQ 2 5 x 2 5 0 R L K E /D I 1 5 V R E G Y e llo w 1 2 V 5 K 6 L K E /1 5 V 2 4 V IN C 0 V 1 5 V IN C S e n s o r Note: If LKE/DI is fitted, there is a special strategy module to support it (see LKE installation instructions TG102847). 4 IQ251 Controller Data Sheet TA102315 Issue 3/A 24/7/02 Data Sheet IQ251 HARDWARE (continued) Side View Top View To install a link header on a channel, the input links are removed and the link header is plugged onto the input linking pins of the EIN board, with the link header board nearest the input connector as shown: A In -1 IN C A In 12345 IN C 12345 12345 12345 A In -1 A In link header in position A In + 1 IN C A In + 1 A I4 IN C A I4 link header board nearest to input connector input connector Displays and Local Supervisor: The IQ251 has 2 ports, the local supervisor port on the front panel (RJ11) and the NDP port under the top cover on the main board. These correspond to the two extra CNC addresses provided by the IQ251: the local supervisor port address, and the NDP port address. Unit with cover removed AUX +24 V supply NDP 24 V supply NDP port O N A D D R E S S local supervisor port (RJ11) Network Display Panel: The optional NDP can be mounted integrally on the front cover, using the NDP port and a special 24 V connector, or remotely, using the local supervisor port (RJ11) and the AUX supply connector. It provides access to all IQ controllers on a single or multi-Lan system without the need for an additional node controller although it does have its own network address. Using icons, and softkeys it allows an operator to perform, under password protection, supervisory functions, such as setpoint adjustments, or to view logs and alarms from all controllers on the system. It can be powered from the IQ251. It uses 75 mA from the 24 Vdc supply (see auxiliary supply section above). If an NDP is connected externally, the CABLE/EJ1104029 should be used to connect both the signal (RJ11) and power (AUX). Supervisor: A PC running a Trend Supervisor or Utility program can be connected to the network via the controller’s supervisor port without the need for an additional node controller although it does have its own network address. When connected in this way the PC will have access to all devices on the network, and will function as if it were connected via its own node controller. Note that if the NDP is connected externally via the local supervisor port (RJ11) it uses the local supervisor port address (not NDP port address). The diagram below illustrates the combinations in which NDPs and local supervisor/engineering tools can be connected. Integral NDP option 13 # O N A D D R E S S PC or NDP (connected via supervisor port) IQ251 Controller Data Sheet TA102315 Issue 3/A 24/7/02 N D P 5 IQ251 Data Sheet HARDWARE (continued) Integral Node :If required an additional node controller (e.g. TMNH, TMNE, CNC2, PNC2, INC2, LINC/FTT) may be fitted inside the IQ251 using the node fixing kit. KIT/NODE/IQ25x. The fixing kit contains nylon pillars which are screwed into the 4 aluminium threaded inserts on the IQ251. The node card has 4 semi-circular cutouts that fit between the fixing screws; the screws are then tightened to clamp the board. There is a special 24 Vdc supply connection (labelled XNC) and a network connector (labelled MNC). The two on-board network links must be removed to enable the network to connect to the node. node supply (XNC) network links Note that an additional node controller will consume current from the 24 Vdc auxiliary supply; see auxiliary supply section above and appropriate node controller data sheet. There is a front panel knockout for RS232 to auxiliary node, and a circular knockout for other auxiliary node cables. node network connection (MNC) O N A D D R E S S COMPATIBILITY Supervisors: Utility software: Controllers: Interface: Local Display: 94x series, 921, NDP (V2.3 or greater), 962, Viewpoint+, 915. PowerTool, 822+/Toolbox version 6, 841 Strategy Browser (Vx), 842 Change Tracker, SET, WupDn. It can communicate to other Trend IQ controllers using inter-controller communications. It can be connected to Trend interface modules. Check interface module specification to ensure compatibility. Network Display Panel. The IQ Configuration Reference Manual Addendum covers the compatibility between different types of strategy files, and between the IQ251 sensor logs, and supervisors and software tools. 6 IQ251 Controller Data Sheet TA102315 Issue 3/A 24/7/02 Data Sheet IQ251 INSTALLATION CONNECTIONS Supply /230 Auxiliary Supply Output IEC 24 Vdc at 500 mA /24 VAC 24 Vdc 0 V yellow green blue see also external NDP below 24 Vac 0V } 24 Vac } 24 Vdc earth 13 /24 VDC # O N yellow green blue A D D R E S S optional earthing bars +24 V 0V earth 24 V units have 2 part Mat-N-Loc connectors Inputs and Outputs Inputs (EIN module) Local Supervisor Port 8 A I1 IN A I2 C IN A I3 C IN A I4 C 8 A I5 IN C IN A I6 C IN A I7 C A I8 IN C IN D I2 D I1 C IN C D I3 IN C IN D I4 C IN D I5 C D I6 IN C IN D I7 C IN C D I8 RJ11 (FCC68) IN see also external NDP below C Analogue Outputs (EAO module) 8 A O 2 O U T C A O 1 O U T C A O 3 O U T C A O 4 O U T C A O 5 O U T C A O 6 O U T C A O 7 O U T C RJ11 to 9 way ‘D type’ female cable CABLE/EJ101442 A O 8 O U T C Network Digital Outputs (EDO module) 2 wire 8 N E T W O R K O U T C D O 1 N o N c C D O 2 N o N c D O 3 N o N c C C D O 4 N o N c C D O 5 N o N c C D O 6 N o N c C D O 7 N o N c C D O 8 N o N c C A U T IO N H IG H V O L T A G E M A Y B E P R E S E N T IS O L A T E E L S E W H E R E e a r th in g T - External NDP IN R - T + T - R + R + R - T + b a r 4 wire N E T W O R K O U T IN (recommended connection) e a r th in g either connect signal and power single cable T - + 9 way 'D' type female T + R - R + T - T + R - b a r R + AUX supply - 24 Vdc 0 V Supervisor Port + RJ11 CABLE/EJ103952 IQ251 Controller Data Sheet TA102315 Issue 3/A 24/7/02 7 IQ251 Data Sheet INSTALLATION (continued) The IQ251 Controller is installed in a cabinet or panel using 4 screws and washers. For IQ251/USA, the unit is UL rated as ‘UL916, enclosed energy management equipment’. The procedure involves: Mount the controller in position Fit earthing bars (if required) Route and tie cables Fit I/O modules Connect I/O Connect power, do not power up Connect network Connect auxiliary supply output (if used) Isolate and disconnect I/O Set network address and baud rate Link analog input channels Fit link headers (if required) Set digital output links (if required) Switch On Check controller Check network Configure strategy Check operation Backup strategy Close panel The installation procedure is covered in the IQ251 Installation Instructions TG103483. Sections (1.3, 2.1, 2.2, 3.1). Sections 3.3, 3.4 cover mounting in an enclosure (ENCLS) and connecting a PC. Section 4.1 covers connecting an external NDP and section 4.3 covers resetting the IQ251. Other installation Instructions: Post fitting an integral NDP Fitting link headers Fitting an integral node Fitting an external NDP or ENCLS/FNDP 8 KIT/ENDP/IQ251 installation instructions LKE installation instructions KIT/NODE/IQ25x NDP installation instructions TG200593 TG102487 TG200595 TG200168 IQ251 Controller Data Sheet TA102315 Issue 3/A 24/7/02 Data Sheet IQ251 FIELD MAINTENANCE The IQ Controller requires virtually no routine maintenance, however it is recommended that the lithium battery be replaced every 5 years, as explained in the IQ251 Installation Instructions, TG103483, Section 4.2 Replacing the Battery. DISPOSAL COSHH ASSESSMENT FOR DISPOSAL OF IQ CONTROLLER. The only part affected is the lithium battery which must be disposed of in a controlled way. RECYCLING. All plastic and metal parts are recyclable. The printed circuit board may be sent to any PCB recovery contractor to recover some of the components for any metals such as gold and silver. IQ251 Controller Data Sheet TA102315 Issue 3/A 24/7/02 9 IQ251 Data Sheet ORDER CODES IQ251/[Display]/[Node]/[I/O Modules]/[Power] [Display] [Node] [I/O Modules] [Power] blank IQ251 with no display blank No node EIN 8 analogue + 8 digital inputs ENDP IQ251 with NDP on front cover TMNH Node including integral modem EAO 8 analogue voltage outputs 24VAC 24 Vac power supply TMNE Node for external modem EDO 8 digital outputs 24VDC 24 Vdc power supply CNC2 Node for Trend network PNC2 Node for remote printer INC2 Node for Trend Internetwork LINC/FTT Node for LonWorks network e.g. 230 230 Vac power supply Only specify the modules required (Max 8 I/O modules) IQ251/TMNH/4EIN/3EDO/230 Specifies an IQ251 with integral modem node, 4 input modules, and 3 digital output modules with 230 Vac supply. Controller comes complete with mains cable and moulded IEC connector (230 V) or supply cable and MAT-N-LOC connector (24 V). PART/LA102359K KIT/NODE/IQ25x ENCLS ENCLS/FNDP KIT/ENDP/IQ251 LKE/5V LKE/15V LKE/10mA LKE/DI CABLE/EJ101442 CABLE/EJ103952 BLT 10 Earthing bar with fixing screw and nuts and bag of earthing screws. Kit for fixing an auxiliary node card in IQ251 or IQ250 (appropriate node cards listed above; node card must be ordered separately). 600 mm x 600 mm x 210 mm IP55 enclosure. 600 mm x 600 mm x 210 mm IP55 enclosure with NDP fitted in front of enclosure. Kit for fitting an integral NDP into the IQ251. Link header to convert an analogue channel to provide 5 V, 20 mA sensor supply. Pack of 8. Link header to convert an analogue channel to provide 15 V, 20 mA sensor supply. Pack of 8. Link header to convert an analogue channel to provide 10 mA sensor supply (e.g. for potentiometer). Pack of 8. Link header to convert an analogue input channel to a digital input (needs special strategy to be configured). Pack of 8. Adaptor cable RJ11 to 9 Way D type female for local PC connection. Adaptor cable 9 Way D type female and 2 terminal power to RJ11 and 2 terminal power for use with NDP. Balanced line transmitter converts IQ251 network output to a balanced signal. IQ251 Controller Data Sheet TA102315 Issue 3/A 24/7/02 Data Sheet IQ251 SPECIFICATIONS CONTROLLER Electrical Mechanical CPU CPU speed Cycle time Memory :68EC020 32 bit processor :16.67 MHz :1 s :512 kbyte battery-backed SRAM, and 512 kbyte flash. Supply voltage 230 /24VAC /24VDC Auxiliary supply :230 Vac, +15% -10%, 50 to 60 Hz :24 Vac, +25% -10%, 50 to 60 Hz :24 Vdc, +25% -10%, (24 V to 36 Vdc) :24 Vdc ±10% 500 mA maximum (typical) dependent on configuration (see auxiliary supply section for details) Consumption :100 VA maximum Fusing :No replaceable fuses required. All protection self resetting. Battery backup :Battery maintains time, and logged data with mains off for at least 5 years. Battery :Saft LM2450, 3 V, or equivalent Clock accuracy :30 s per month (typical). Network display panel :Icon driven display panel with backlit display, for use on single or multi Lan systems. Can be mounted in front cover, or remotely. Network :20 mA serial 2 wire current loop, opto isolated, polarity independent receiver. Balanced line transmission can be achieved with addition of BLT module. Supervisor transmission :RS232, EIA/TIA/232E, V28 Distance supervisor network Cable Belden 9182 Belden 9207 Trend 1000 m TP/1/1/22/HF/500 (1090 yds) (Belden 8761) Trend 1000 m TP/2/2/22/HF/500 (1090 yds) (Belden 8723) Baud rate network NDP supervisor Network addresses Controller Supervisor port NDP port Input or Output modules Material Chassis I/O modules Cover Protection Weight Connector I/O modules power network supervisor NDP UL 2 2 Indicator Lamps 350 m (380 yds) 2 PWR 250 m (270 yds) 4 WD 9k6 baud 1000 m (1090 yds) 1000 m (1090 yds) 19k2 baud 700 m (765 yds) 500 m (545 yds) 700 m (765 yds) 500 m (545 yds) No. of Wires I/O LAN :Selectable by switch 1k2, 9k6, or 19k2. :9k6. :9k6. :Selectable by switch, 116 nodes addressable (1,4 to 119 excluding 10) set to be unique on Lan. :Software selectable, 116 nodes addressable (1, 4 to 119 excluding 10) set to be unique on Lan. :Software selectable, 116 nodes addressable (1, 4 to 119 excluding 10) set to be unique on Lan. :550 mm (21.7”) x 440 mm (7.32”) x 175 mm (6.9”) :Zinc plated and passivated mild steel :Extruded aluminium with alocrom finish. :Fire retardant moulded ABS. :IP20 :14.5 kg (32 lbs) (fully loaded) :2 part connector, 50 mm (1.97”) half pitch :IEC plug (230 V) Mat-N-Loc (24 V) :2 part connector with 8 screw terminals for 0.5 to 2.5 mm2 cross section area (14 to 20 AWG) cable. :RJ11 (FCC68), 6 pin, for Trend utility software connected via adaptor cable PART/10/1442. :3 pin in line to 9 way D type connector cable (supplied with KIT/NODE/IQ25x). :(IQ251/USA only). The unit is UL rated as ‘UL916, enclosed energy management equipment’. Environmental EMC emissions immunity Safety Ambient limits storage operating humidity :15 m (16 yds) :Dependent on cable type, see table below. 1k2 baud 1000 m (1090 yds) 1000 m (1090 yds) Dimensions TX RX :EN50081-1. :prEN50082-2. :EN61010. :-10 °C (14 °F) to 50 °C (122 °F) :0 °C (32 °F) to 45 °C (113 °F) :0 to 90 %RH non-condensing :(green) ON when power supply is connected. :(red) ON if controller has a software fault. :(red) Flashes during normal operation. :(green) ON if network is operating. Flashes if prohibited controller network address set (0, 2, 3, >119). :(yellow) ON if current is flowing from the network transmitter. :(yellow) ON if current is entering the network receiver. :8 modules in total. Any module type may be fitted in any position. Module types are: EIN 8 analogue and 8 digital inputs EAO 8 analogue outputs EDO 8 digital outputs IQ251 Controller Data Sheet TA102315 Issue 3/A 24/7/02 11 IQ251 Data Sheet SPECIFICATIONS (continued) I/O MODULES Dimensions 8 Analogue Output Module (/EAO/) :72 mm (2.83”) x 202 mm (7.95”) x 43 mm (1.69”) :0.3 kg approx. (0.66 lbs) Weight Connector Main board Analogue outputs Status LED inputs/Outputs Signal Cable :2 part connector, 50 mm (1.97”) half pitch :2 part connector screw terminals for 0.5 to 2.5 mm2 cross section area (14 to 20 AWG) cable. :Analogue Voltage, Current, Thermistor, or Digital inputs, and Analogue outputs. Trend TP/1/1/22/HF/500 recommended (Belden 8761) 8 Digital Output Module (/EDO/) Digital outputs 8 Analogue, 8 Digital Input Module (/EIN/) Analogue inputs V I T Digital inputs Status LED :12 bit resolution (4096 steps). Minimum 60 dB series mode rejection at supply frequency. Linkable for analogue current (I), analogue voltage (V), or thermistor (T) :0 to 10 V input resistance 200 kΩ, accuracy 50 mV equivalent to ±0.5% of span. :0 to 20 mA input resistance 250 Ω 0.1%, accuracy 0.5 % of span (i.e. 100 µA) :Thermistor, bridge resistor 10 kΩ 0.1%, accuracy 0.5 % of span. Bridge supply 5V. :Volt free contact, or 24 Vdc self powered contact. Wetting current 5 mA @ 24 Vdc, count rate 32 Hz max. :(yellow) One per digital input. ON if input is closed :8 bit resolution (256 steps). 0 to 10 V with 20 mA current limit, accuracy ±50mV equivalent to ±0.5 % span. :(yellow) 1 per channel. Light intensity increases with output voltage. Status LED Manual override Version firmware boards EIN EAO EDO CPU PSU :Single pole change over relay, contacts rated for 240 Vac single phase only 8A (resistive load), 5A (inductive, cosØ=0.4), 30 Vdc at 5A (resistive load), and 20 Vdc at 5A (inductive load). For 24 Vdc (inductive load) reduce to 2A. Arc suppression recommended, see Relay Output Arc suppression Installation Instructions, TG200208). IQ251/USA only: Relay outputs are UL rated up to 30 V. :(yellow) 1 per channel. ON when relay is energised. :Each channel is linkable for ON, OFF, or AUTO. This document covers :V3 or greater :AM101687 :AM101721 :AM102022 :AM101701 :AM102060 v3 v1.1 v1.1 v1 v2.2 Trend Control Systems Ltd reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions or changes. Trend Control Systems Ltd. P.O. Box 34 Horsham Sussex RH12 2YF England Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trend-controls.com 12 IQ251 Controller Data Sheet TA102315 Issue 3/A 24/7/02
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement