Matrix Solenoid III
Matrix Solenoid III
Duty Cycle - Continuous
Item number
Coil
Voltage
Coil
Ohms
# of
Studs
Housing
Material
Contact Ratings
Contact
Material
Coil Type
Bracket
Style
24420
12
17.5
4
Metal
Normally Closed Continuous Duty
12V DC 35A
Copper
Insulated
Flat
24059
12
17.5
4
Metal
Continuous Duty 6-36V DC85A Carry,
125A Make & Break
Copper
Insulated
Flat
Copper
Insulated
Flat
24059-08
12
17.5
4
Metal
UL & CE Continuous Rating
at12 VDC 65A UL & CE Intermittent
Rating at12VDC 750A Make,
100A Break10 seconds on,
30 minutes off
24063
24
71
4
Metal
Continuous Duty
6-36V DC 85A Carry,
125A Make & Break
Copper
Insulated
Flat
Copper
Insulated
Flat
24063-08
24
71
4
Metal
UL & CE Continuous Rating 24V DC 65A
UL & CE Intermittent Rating 24V DC
120A Make, 65A Break
10 seconds on, 30 minutes off
24080
36
130
4
Metal
Continuous Duty
6-36V DC 85A Carry,
125A Make & Break
Copper
Insulated
Flat
24082
12
17.5
4
Metal
Continuous Duty
6-36V DC 85A Carry,
125A Make & Break
Copper
Grounded
Curved
24097
6
4.2
4
Metal
Continuous Duty
6-36V DC 85A Carry,
125A Make & Break
Copper
Insulated
Flat
24106
12
17.5
3
Metal
Continuous Duty
6-36V DC 85A Carry,
125A Make & Break
Copper
Grounded
Flat
24107
24
71
3
Metal
Continuous Duty
6-36V DC 85A Carry,
125A Make & Break
Copper
Insulated
Flat
Copper
Insulated
Flat
24115
12
17.5
3
Metal
Continuous Duty
6-36V DC
85A Carry, 125A
Make & Break
24117
12
17.5
4
Metal
Continuous Duty
6-36V DC 85A Carry,
125A Make & Break
Copper
Insulated
Flat
Copper
Insulated
Flat
Additional
Notes
UL & CE Approved
UL & CE Approved
24117-01
12
17.5
4
Metal
UL & CE Continuous Rating
at12 VDC 65A
UL & CE Intermittent Rating at 12VDC
750A Make, 100A Break
10 seconds on,
30 minutes off
24124
24
71
3
Metal
Continuous Duty
6-36V DC 85A Carry,
125A Make & Break
Copper
Grounded
Flat
24143
12
17.5
4
Metal
Continous Duty 12V DC
200A Make & Break
Inrush 600A
Silver Inlay
Insulated
Flat
Silver Contact
Surfaces
24144
24
71
4
Metal
Continous Duty 24V DC
200A Carry Only
150A Make & Break
Silver Inlay
Insulated
Flat
Silver Contact
Surfaces
UL & CE Approved
Duty Cycle - Continuous (continuted from previous page)
Item number
24400
24401
24401-01
24401-04
Coil
Voltage
36
12
12
12
Coil
Ohms
130
17.5
17.5
17.5
# of
Studs
6
6
6
6
Housing
Material
Contact Ratings
Contact
Material
Coil Type
Bracket
Style
Metal
Continuous Duty
Normally Closed
Contacts 35A
Normally Open
Contacts 85A
Copper
Insulated
Flat
Metal
Continuous Duty
Normally Closed
Contacts 35A
Normally Open
Contacts 85A
Copper
Insulated
Flat
Metal
Continuous Duty
Normally Closed
Contacts 35A
Normally Open
Contacts 85A
Copper
Grounded
Flat
Metal
Continuous Duty
Normally Closed
Contacts 35A
Normally Open
Contacts 85A
Copper
Insulated
Flat
Copper
Insulated
Flat
24402
24
71
6
Metal
Continuous Duty
Normally Closed
Contacts 35A
Normally Open
Contacts 85A
24512-10
12
18.6
4
Nylon
Continuous Duty
100 A Inrush 400A
Silver
Insulated
F
24612
12
18.6
4
Nylon
Continuous Duty
100 A Inrush 400A
Silver
Insulated
L
24612-10
12
18.6
4
Nylon
Continuous Duty
100 A Inrush 400A
Silver
Insulated
F
24612-G10
12
18.6
3
Nylon
Continuous Duty
100 A Inrush 400A
Silver
Grounded
F
24624-10
24
76
4
Nylon
Continuous Duty
100 A Inrush 400A
Silver
Insulated
F
24812
12
7.7
4
Nylon
Continuous Duty
225A Inrush 600A
Copper
Insulated
L
24812-01
12
7.7
4
Nylon
Continuous Duty
225A Inrush 600A
Silver
Insulated
L
24824-01
24
32
4
Nylon
Continuous Duty
225A Inrush 600A
Silver
Insulated
L
Additional
Notes
Duty Cycle: Intermittent (continuted from previous page)
Item number
24008
24021
24022
Coil
Voltage
24
12
12
Coil
Ohms
29
3.8
3.8
# of Studs
4
4
3
Housing
Material
Contact Ratings
Contact
Material
Coil Type
Bracket
Style
Metal
Intermittent Duty 24-36V DC 120A
Make, 65A
Break 10 seconds On,
30 Minutes Off
Copper
Insulated
Flat
Phenolic
UL & CE Intermittent Rating at 12VDC
750A Make, 100A
Break10 seconds on,
30 minutes off
Copper
Grounded
Flat
Phenolic
UL & CE Intermittent Rating at 12VDC
750A Make, 100A
Break10 seconds on,
30 minutes off
Copper
Grounded
Flat
Copper
Insulated
Flat
24023
12
3.8
4
Phenolic
UL & CE Intermittent Rating at 12VDC
750A Make, 100A Break
10 seconds on,
30 minutes off
24037
12
4.4
3
Metal
Intermittent Duty 6-12V DC 750A
Make, 100A Break 10 seconds On,
20 Minutes Off
Copper
Grounded
Flat
24039
6
1.6
3
Metal
Intermittent Duty 6-12V DC 750A
Make, 100A Break 10 seconds On,
20 Minutes Off
Copper
Grounded
Curved
24041
6
1.6
3
Metal
Intermittent Duty 6-12V DC 750A
Make, 100A Break 10 seconds On,
20 Minutes Off
Copper
Grounded
Flat
24044
12
4.4
3
Metal
Intermittent Duty 6-12V DC 750A
Make, 100A Break 10 seconds On,
20 Minutes Off
Copper
Grounded
Curved
24046
12
4.4
3
Metal
Intermittent Duty 6-12V DC 750A
Make, 100A Break 10 seconds On,
20 Minutes Off
Copper
Insulated
Flat
24047
12
4.4
4
Metal
Intermittent Duty 6-12V DC 750A
Make, 100A Break 10 seconds On,
20 Minutes Off
Copper
Insulated
Flat
24060
12
4.4
3
Metal
Intermittent Duty 6-12V DC 750A
Make, 100A Break 10 seconds On,
20 Minutes Off
Copper
Insulated
Flat
24071
12
4.4
3
Metal
Intermittent Duty 6-12V DC 750A
Make, 100A Break 10 seconds On,
20 Minutes Off
Copper
Grounded
Flat
24076
12
4.4
4
Metal
Intermittent Duty 6-12V DC
750A Make, 100A Break
10 seconds On, 20 Minutes Off
Copper
Insulated
Flat
24103
12
4.4
4
Metal
Intermittent Duty 6-12V DC
750A Make, 100A Break
10 seconds On, 20 Minutes Off
Copper
Grounded
Flat
24104
24
29
3
Metal
Intermittent Duty 6-12V DC
750A Make, 100A Break
10 seconds On, 20 Minutes Off
Copper
Insulated
Flat
2430
12
3.8
3
Metal
UL & CE Intermittent Rating
at 12VDC 750A Make, 100A Break
10 seconds on, 30 minutes off
Copper
Insulated
Flat
Additional Notes
Contains ignition coil
shorting resistor
Contains ignition coil
shorting resistor
Duty Cycle: Intermittent (continuted from previous page)
Item number
Coil
Voltage
Coil
Ohms
# of
Studs
Housing
Material
Contact Ratings
Contact
Material
Coil Type
Bracket
Style
Additional
Notes
24612-03
12
3.8
4
Nylon
Intermittent Duty
200A 5 seconds on 5 minutes off
Inrush 300A
Copper
Insulated
L
24612-13
12
3.8
4
Nylon
Intermittent Duty
200A 5 seconds on 5 minutes off
Inrush 300A
Copper
Insulated
M-200
12
4.4
4
Metal
Intermittent Duty 6-12V DC
750A Make, 100A Break
10 seconds On, 20 Minutes Off
Copper
Insulated
Flat
M-200-01
12
4.4
4
Metal
UL & CE Intermittent Rating
at 12VDC 750A Make, 100A Break
10 seconds on, 30 minutes off
Copper
Insulated
Flat
M-202
12
4.4
3
Metal
Intermittent Duty 6-12V DC
750A Make, 100A Break
10 seconds On, 20 Minutes Off
Copper
Grounded
Flat
U
UL & CE Approved
Duty Cycle - Latched
Item number
Coil
Voltage
Coil
Ohms
# of Studs
Housing
Material
Contact Ratings
Contact
Material
Coil Type
Bracket
Style
Additional
Notes
24200
12
3.1
4
Metal
Continuous Duty (Carry Only)
6-36V DC 110A
Copper
Insulated
Flat
Mecanical
Latching Feature
Littlefuse Commercial Vehicle Products • 20 Old Colony Avenue, Boston, MA USA 02127-2467 • 617-268-2100 • Fax 617-268-9490