advertisement
2
GraphiteVPX/GbE 20-Port
Managed Carrier Ethernet Switch
Connect Tech Inc.
42 Arrow Road
Guelph, Ontario
N1K 1S6
www.connecttech.com
CTIM-00461 Revision 0.02 2016/10/27
Tel:
519-836-1291
Toll:
800-426-8979 (North America only)
Fax:
519-836-4878
Email:
[email protected] [email protected]
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Table of Contents
Document: CTIM-00461
Revision: 0.02
Page 2 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Preface
Disclaimer
The information contained within this user’s guide, including but not limited to any product specification, is subject to change without notice.
Connect Tech assumes no liability for any damages incurred directly or indirectly from any technical or typographical errors or omissions contained herein or for discrepancies between the product and the user’s guide.
Customer Support Overview
If you experience difficulties after reading the manual and/or using the product, contact the Connect Tech reseller from which you purchased the product. In most cases the reseller can help you with product installation and difficulties.
In the event that the reseller is unable to resolve your problem, our highly qualified support staff can assist you.
Our support section is available 24 hours a day, 7 days a week on our website at: www.connecttech.com/sub/support/support.asp.
See the contact information section below for more information on how to contact us directly. Our technical support is always free.
Contact Information
Mail/Courier
Connect Tech Inc.
Technical Support
42 Arrow Road
Guelph, Ontario
Canada N1K 1S6
Email/Internet
[email protected] [email protected] www.connecttech.com
Note:
Please go to the Download Zone or the
Knowledge Database
in the
Support Center
on the Connect Tech website for product manuals, installation guides, device driver software and technical tips.
Submit your technical support questions to our customer support engineers via the
Support Center
on the
Connect Tech website.
Telephone/Facsimile
Technical Support representatives are ready to answer your call Monday through Friday, from 8:30 a.m. to
5:00 p.m. Eastern Standard Time. Our numbers for calls are:
Toll Free: 800-426-8979 (North America only)
Telephone: 519-836-1291 (Live assistance available 8:30 a.m. to 5:00 p.m. EST, Monday to Friday)
Facsimile: 519-836-4878 (on-line 24 hours)
Document: CTIM-00461
Revision: 0.02
Page 3 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Limited Product Warranty
Connect Tech Inc. provides a 2 year Warranty for the GraphiteVPX/GbE 20-Port - Managed Carrier Ethernet
Switch. Should this product, in Connect Tech Inc.'s opinion, fail to be in good working order during the warranty period, Connect Tech Inc. will, at its option, repair or replace this product at no charge, provided that the product has not been subjected to abuse, misuse, accident, disaster or non-Connect Tech Inc. authorized modification or repair.
You may obtain warranty service by delivering this product to an authorized Connect Tech Inc. business partner or to Connect Tech Inc. along with proof of purchase. Product returned to Connect Tech Inc. must be pre-authorized by Connect Tech Inc. with an RMA (Return Material Authorization) number marked on the outside of the package and sent prepaid, insured and packaged for safe shipment. Connect Tech Inc. will return this product by prepaid ground shipment service.
The Connect Tech Inc. Limited Warranty is only valid over the serviceable life of the product. This is defined as the period during which all components are available. Should the product prove to be irreparable, Connect
Tech Inc. reserves the right to substitute an equivalent product if available or to retract the Warranty if no replacement is available.
The above warranty is the only warranty authorized by Connect Tech Inc. Under no circumstances will
Connect Tech Inc. be liable in any way for any damages, including any lost profits, lost savings or other incidental or consequential damages arising out of the use of, or inability to use, such product.
Copyright Notice
The information contained in this document is subject to change without notice. Connect Tech Inc. shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Connect Tech, Inc.
Copyright 2015 by Connect Tech, Inc.
Trademark Acknowledgment
Connect Tech, Inc. acknowledges all trademarks, registered trademarks and/or copyrights referred to in this document as the property of their respective owners. Not listing all possible trademarks or copyright acknowledgments does not constitute a lack of acknowledgment to the rightful owners of the trademarks and copyrights mentioned in this document.
Document: CTIM-00461
Revision: 0.02
Page 4 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
ESD Warning
Electronic components and circuits are sensitive to
ElectroStatic Discharge (ESD). When handling any circuit board assemblies including Connect Tech COM Express carrier assemblies, it is recommended that ESD safety precautions be observed. ESD safe best practices include, but are not limited to:
Leaving circuit boards in their antistatic packaging until they are ready to be installed.
Using a grounded wrist strap when handling circuit boards, at a minimum you should touch a grounded metal object to dissipate any static charge that may be present on you.
Only handling circuit boards in ESD safe areas, which may include ESD floor and table mats, wrist strap stations and ESD safe lab coats.
Avoiding handling circuit boards in carpeted areas.
Try to handle the board by the edges, avoiding contact with components.
Revision History
Revision
0.00
0.01
0.02
Date
27/04/2016
18/06/2016
27/10/2016
Changes
Initial Release
Added I2C sensor info, updated pictures.
Removed pinout details, updated title page
Document: CTIM-00461
Revision: 0.02
Page 5 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Introduction
Connect Tech’s GraphiteVPX/GbE Managed Ethernet Switch provides Carrier Grade Ethernet switching capabilities in a small 3U embedded form factor. Excellent for demanding applications with rugged environments and extreme temperatures.
The GraphiteVPX/GbE Managed Ethernet Switch is also a highly reliable way to communicate with
10/100/1000 Base-T devices in an embedded system. Powered by the latest generation Carrier Ethernet Switch engine, the Vitesse 7429 features an embedded MIPS 32-bit CPU, 1Gb external memory and DMA-based frame extraction and insertion support timing over packet, Ethernet OAM, and performance monitoring.
Feature
Ethernet Switch Engine
Description
Ethernet PHYs
Memories
Ports
Magnetics
I/O Connectors
Layer 2 Switching
Management Access
Vitesse VSC7429 Carrier Grade Ethernet Switch Chipset
A powerful embedded 416 MHz RISC 32-bit CPU with DDR2 external memory and DMA-based frame extraction and insertion supports timing over packet, Ethernet OAM, and performance monitoring.
8 x Cu PHY Ports from Vitesse VSC7429 Switch Engine
12 x Cu PHY Ports from Vitesse VSC8512 External PHY
1Gb DDR2 SDRAM (125MB)
128Mb Serial NOR Flash (16MB)
20 x Gigabit Ethernet (10/100/1000 Mbps )
On-board Gigabit Magnetics for all 20 Ports (No external Magnetics required)
Designed for Long-haul Gigabit Ethernet (10/100/1000 Mbps) applications
Standard VPX Backplane connectors
4x RJ45 front panel connectors
RJ11 connector for RS232 CLI access
802.1Q VLAN switch with 8K MACs and 4K VLANs
Push/pop up to two VLAN tags
IPv4/IPv6 multicast
Policing with storm control and MC/BC protection
RSTP and MSTP support
Hardware and software-based learning
Link aggregation (IEEE 802.3ad)
Independent and shared VLAN learning (IVL, SVL)
Jumbo frame support
Web Interface
CLI via RS-232
Software API
SMNP
Document: CTIM-00461
Revision: 0.02
Page 6 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
Indicator LEDs
Standalone Operation
Input Voltage
Power Consumption
Dimensions
Weight
Operating Temp
Warranty and Support
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
2 LEDs per port indicating connection speed
Power Good LED
Fail Status LED
Thermal Trip LED
Switch is used as a standalone unit
5V (VS3) and 3.3V_AUX
Idle: 1.8A, 9W Typical: 2A, 10W Max: 3A, 15W (with +5V input)
Standard 1” Pitch VPX
VPG201 = 380g
VPG202 = 390g
-40°C to +85°C (chipset rated to +125°C TJmax)
Two Year Warranty and Free Technical Support
Document: CTIM-00461
Revision: 0.02
Page 7 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
Product Overview
The
Block Diagram
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Document: CTIM-00461
Revision: 0.02
Page 8 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
Ordering Part Numbers
Part Number Photo
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Description
VPG201
Air Cooled 20 port GbE Switch, 16 backplane channels, 4 RJ45 channels on the front panel
VPG202
Conduction Cooled 16 port GbE Switch, 16 backplane channels
RTG002
3U extended RTM, with 16 RJ45 channels
Document: CTIM-00461
Revision: 0.02
Page 9 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
Connector Locations (VPG201)
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Note the VPG202 has P3 and P4 removed.
Document: CTIM-00461
Revision: 0.02
Page 10 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
Connector Summary
Designator
P0
Connector
VPX P0
P1
P2
P3
VPX P1
VPX P2
RJ11
P4
J1
RJ45
2x5 Jumper Block
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Description
Standard VPX connector, has all POWER, CTRL signals
Is fully populated with 8 GbE BaseT channels
Is fully populated with 8 GbE BaseT channels
RJ11 for serial communications with the Ethernet switch, VPG201 only
4x RJ45 connectors for additional access
N/A
Document: CTIM-00461
Revision: 0.02
Page 11 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
VPG20x - Detailed Feature Pinouts
Full pinout details are available only under an NDA (Non-Disclosure Agreement). Please contact sales at Connect
Tech Inc. for further information.
1-800-426-8979 [email protected]
http://www.connecttech.com
Document: CTIM-00461
Revision: 0.02
Page 12 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
CLI Management Interface
CLI Access via the RS232 Serial Port
To use the CLI management on the VPG you must connect to the RS-232 external management serial port (P3) or through the backplane serial port connection. Only TX, RX and GND connections are needed for operation.
You then must open the serial port in a terminal program such as: RealTerm, Putty, HyperTerminal, minicom, etc. The COM port must be set up to run with a baud rate of 115200, 8 data bits, 1 stop bit and no parity.
Note: the VPG external serial port is compatible with RS-232 Input/Output Levels (NOT TTL or CMOS).
RS-232 Serial Parameter Value
Baud Rate
Data Bits
115200 bps
8
Parity
Stop Bit
Output Voltage Swing
Input Voltage Range
Input Threshold Low
Input Threshold High
None
1
±4.2 V
±15 V
0.8 V
2.4 V
Document: CTIM-00461
Revision: 0.02
Page 13 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
CLI Basics
Once opening the COM port attached to the management port, after boot up your terminal output should look like the output below. The default login is admin and password is blank(“”). So after typing admin hit
<ENTER> then hit <ENTER> again to login and “?” will display a list of the available commands.
Below is a list of common quick CLI commands. For a complete CLI reference please see the documents described below.
Common Task CLI Command Syntax show ? OR show ip int ?
Help menu – from any level, add a ‘?’ to the end of a command for a list of options at that level.
What are the IP addresses used by my switch?
What ports are linked and at what speed?
What software version is on my switch?
How do I save my configuration?
How do I setup my IP address for vlan1?
show ip int br show int * status show ver copy running-config startup-config conf t int vlan 1 ip add xxx.xxx.xxx.xxx 255.255.255.0
end
Complete CLI and Protocol Configuration Reference Guide
The complete CLI and Protocol Configuration reference guide from Microsemi for the VSC7429 device can be
downloaded here.
The following documents:
- AN1104-Software_Configuration_Guide_ICLI
- AN1115Layer2ProtocolConfigurationGuide
Will have the below mentioned copyright notice.
Copyright 2002-2015 Microsemi Corporation. All Rights Reserved. Unpublished rights reserved under the copyright laws of the United States of America, other countries and international treaties. Microsemi retains all ownership, copyright, trade secret and proprietary rights in the documentation.
Document: CTIM-00461
Revision: 0.02
Page 14 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Web Management Interface
The GraphiteVPX/GbE 16+4 - Port - Managed Carrier Ethernet Switch allows users to configure and monitor the device from any web enabled device. Below describes how to access this management interface as well as provides on overview on the web GUI itself.
Accessing the Web Management Interface
There are two ways to access the web interface for first time use.
Method #1 - Using the default shipping IP
This method DOES NOT require having access to the CLI interface. By default the GraphiteVPX/GbE will have an IP address of 192.168.42.1, if you would like to connect to this address follow the steps below: o Directly connect any port of GraphiteVPX/GbE to your host PC using a standard Cat5e ethernet cable o
Setup your host PC’s IP address to be on the same subnet as GraphiteVPX/GbE (192.168.42.X) o Open a web browser and go to the 192.168.42.1 address. o Now you should see the login screen and from here you can setup the GraphiteVPX/GbE to an IP address on your network.
Method #2 – Changing the GraphiteVPX/GbE IP to one on your network via the CLI
This method requires having access to the CLI interface through means of the external management serial port or the PCIe/104 bus o Login to the CLI interface o Type in the following commands o configure terminal o interface vlan 1 o ip address xxx.xxx.xxx.xxx 255.255.255.0 o end o Now connect GraphiteVPX/GbE to any place on your network. o Once the system is up simply go to your specified address of xxx.xxx.xxx.xxx in a web browser of your choice and you will see the login screen for the web interface
Login Screen of Web Management Interface
To login into the web management interface, the default login is admin and the password is blank.
(See below)
Document: CTIM-00461
Revision: 0.02
Page 15 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Web Management Interface Overview
Complete Web Protocol Configuration Reference Guide
As mentioned in the CLI section, the complete Protocol Configuration reference guide from Microsemi for the
VSC7429 device can be downloaded here. It will have CLI and Web configuration methods listed.
The following document:
- AN1115Layer2ProtocolConfigurationGuide
Will have the below mentioned copyright notice.
Copyright 2002-2015 Microsemi Corporation. All Rights Reserved. Unpublished rights reserved under the copyright laws of the United States of America, other countries and international treaties. Microsemi retains all ownership, copyright, trade secret and proprietary rights in the documentation.
Document: CTIM-00461
Revision: 0.02
Page 16 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Port LED Details
The VPG uses a serialized LED stream to output the LED status for each port. This serial signal is intended to be run through shift registers as shown below to de-serialize the stream. To accommodate the 16 ports
(VPG202 – Backplane only) requires the use of four 8-bit shift registers (or eqivilant) setup in the configuration shown below.
An example circuit is shown below, or an example schematic can be downloaded here.
Document: CTIM-00461
Revision: 0.02
Page 17 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
System Management Interface
The GraphiteVPX/GbE supports a slave I2C slave interface on the SM0 (SCL) and SM1 (SDA) signals connected to the VPX backplane. The I2C address of this interface is determined by the Geographic Address lines GA0#, GA1#, and GA2#. This interface operates at 100 KHz.
There are 10K OHM pull-ups to the +3.3V_AUX supply on the I2C slave interface on SM0 and SM1.
The I2C interface contains an I2C mux device (PCA9544) to allow the user access 5 temperature sensors that monitor board edges and internal temperatures of the Ethernet Switch and Ethernet PHY.
Addressing the I2C Slave Interface (I2C Mux)
As stated above, the I2C slave interface uses GA0#, GA1#, and GA2# to determine its final I2C address. See more details below. Refer to your backplane GA (Geographical Address) lines for the complete configuration address.
The I2C address will be as such:
Bit7
1
BIT6
1
BIT5
1
BIT4
0
BIT3
GA2#
BIT2
GA1#
BIT1
GA0#
BIT0
R/W
Document: CTIM-00461
Revision: 0.02
Page 18 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Writing to the I2C Slave Interface
Refer to the NXP PCA9544 datasheet for access details.
The I2C multiplexor is like a ‘gate’ to open an on board I2C bus to access one of three card side busses:
1) Bus 0 – is a link to one TMP422 (sensor #5) remote temperature sensor (local temp and remote temperatures of VSC7429 and VSC8512).
2) Bus 1 – is a direct link with XMC sites I2C system interface
3) Bus 2 – is a link to 2 TMP101 temperature sensors on the top edge (Sensor 1 and 2)
4) Bus 3 – is a link to 2 TMP101 temperature sensors on the bottom edge (Sensor 3 and 4)
*Refer to the TI TMP101 datasheet for access and setup of ALERT pin interrupt to the PCA9544. A Thermal
Alert LED is accessible on the solder side of the card if a visual indicator is required.
Reading from the I2C devices
When reading from the I2C slave interface, the last value stored in the command register by a write operation is used to determine which command to respond to. To change the command for a read operation, a new command must be written to the command register. This is accomplished by issuing an I2C slave address byte with the R/W# bit LOW, followed by the command byte. The master can then generate a START condition and send the I2C slave address byte with the R/W# bit HIGH to initiate a read command. If repeated reads from the same register are required it is not necessary to continually send the command byte. The slave I2C interface will remember the original command value until it is changed by the next write operation.
Example XML code to open the I2C mux and access the temperature sensors using the Totalphase Aardvark™
USB to I2C controller can be provided by request.
Document: CTIM-00461
Revision: 0.02
Page 19 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Thermal Details
Thermal Parameters
Thermal Parameter
Minimum Ambient Operating Temperature
Maximum Operating Junction Temperature
Recommended VPG TDP
SoC TDP (VSC7429)
PHY TDP (VSC8512)
Die junction to package case top (SoC/PHY)
Die junction to PCB (SoC/PHY)
Die junction to Ambient (SoC/PHY)
Die junction to moving air @ 1 m/s (SoC/PHY)
Value
-40 °C
125 °C
15W
8W
7W
3.27 °C/W
6.03 °C/W
12.14 °C/W
9.42 °C/W
Document: CTIM-00461
Revision: 0.02
Page 20 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Mechanical Details
3D STEP Models
A complete 3D STEP Model file of the VPX GbE Switch can be made available upon request. The VPG20x is a Standard 3U VITA 65 unit, compliant with a 1” pitch VPX backplane layout.
Document: CTIM-00461
Revision: 0.02
Page 21 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
VPG202 Top Side View
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Document: CTIM-00461
Revision: 0.02
Page 22 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
VPG202 – Bottom Side View
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Document: CTIM-00461
Revision: 0.02
Page 23 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
RTM Details
The main purpose of the RTG002 is to allow the ability for development in a lab environment to access all features and GbE channels that are available on the VPG201/VPG202. The RTM is a backplane connectable breakout board.
Document: CTIM-00461
Revision: 0.02
Page 24 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
RTG002 – Pinout Information
Photo
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
Description
P3, J3-J10
Standard GbE RJ45 Pinouts (x16)
P1
I2C (VPX SM Bus) Header – a standard
Totalphase Aardvark™ I2C analyzer will install without need of an adapter
Pinout
Pin 1
Pin 2
Pin 3
I2C_SCL (CLK)
GND
I2C_SDA (DATA)
P2
RJ11 Serial Interface Cable
Pinout
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
N/C
RX – Module Receive
GND
TX – Module Transmit
N/C
N/C
Document: CTIM-00461
Revision: 0.02
Page 25 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
RTG002 – Top Side View
GraphiteVPX/GbE 16+4-Port - Managed Carrier Ethernet Switch
Users Guide
www.connecttech.com
RTG002 – Bottom Side View
Document: CTIM-00461
Revision: 0.02
Page 26 of 26
Connect Tech Inc. 800-426-8979 | 519-836-1291
Date: 2016/10/27
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Table of Contents
- 3 Preface
- 3 Disclaimer
- 3 Customer Support Overview
- 3 Contact Information
- 4 Limited Product Warranty
- 4 Copyright Notice
- 4 Trademark Acknowledgment
- 5 ESD Warning
- 5 Revision History
- 6 Introduction
- 8 Product Overview
- 8 Block Diagram
- 9 Ordering Part Numbers
- 10 Connector Locations (VPG201)
- 11 Connector Summary
- 12 VPG20x - Detailed Feature Pinouts
- 13 CLI Management Interface
- 13 CLI Access via the RS232 Serial Port
- 14 CLI Basics
- 14 Complete CLI and Protocol Configuration Reference Guide
- 15 Web Management Interface
- 15 Accessing the Web Management Interface
- 16 Web Management Interface Overview
- 16 Complete Web Protocol Configuration Reference Guide
- 17 Port LED Details
- 18 System Management Interface
- 18 Addressing the I2C Slave Interface (I2C Mux)
- 19 Writing to the I2C Slave Interface
- 19 Reading from the I2C devices
- 20 Thermal Details
- 20 Thermal Parameters
- 21 Mechanical Details
- 21 3D STEP Models
- 22 VPG202 Top Side View
- 23 VPG202 – Bottom Side View
- 24 RTM Details
- 25 RTG002 – Pinout Information
- 26 RTG002 – Top Side View
- 26 RTG002 – Bottom Side View