advertisement
Regal
Model
®
XL
•
C u y
Am erican
A c
Single-Flush Side Mount Hardwired
t u y
Am erican
A c
•
C o mplian t
Single-Flush Side Mount Hardwired
Description
Exposed, AC-powered, sensor-activated, water closet flushometer with a single-flush side mount unit for top spud floor mounted or wall hung bowls.
Flush Cycle
£ Regal 111-1.6 SFSM HW Low Consumption (1.6 gpf/6.0 Lpf)
Code: 3980096
Variation
£ DFB Dual-Filtered Fixed Bypass Diaphragm
Specifications
Quiet, exposed, diaphragm-type, chrome plated closet flushometer with the following features:
• PERMEX ® Synthetic Rubber Diaphragm with Linear Filtered Bypass with Vortex
Cleansing Action™
• ADA Compliant AC-powered infrared side mount sensor for automatic “No Hands” operation
• Chrome plated infrared sensor housing
• Can be mounted on either left or right side of valve
• True Mechanical Override Flush button
• “User in View” flashing LED
• 72-Hour sentinel flush
• Infrared sensor range adjustment screw and reset button
• 1” IPS screwdriver Bak-Chek ® angle stop with stop plug
• Adjustable tailpiece
• High back pressure vacuum breaker flush connection with one-piece bottom hex coupling nut
• Spud coupling and flange for 1-1/2” top spud
• Sweat solder adapter with cover tube and cast wall flange with set screw
• High copper, low zinc brass castings for dezincification resistance
• No external volume adjustment to ensure water conservation
• Diaphragm, stop seat and vacuum breaker molded from PERMEX rubber compound for chloramine resistance
Valve body, tailpiece and control stop shall be in conformance with ASTM Alloy
Classification for semi-red brass. Valve shall be in compliance with the applicable sections of ASSE 1037, ASME 112.18, ASME 112.19, ANSI 117.1. Installation conforms to ADA requirements.
Accessories (specify separately)
EL-386 120 VAC Input/6 VAC Output, 50/60 Hz (3 VA) Plug-In (will operate 1 unit)
EL-451 120 VAC Input/6 VAC Output, 50/60 Hz (25 VA) Box Mount (will operate up to 6 units)
Fixtures
Consult Sloan for Sloan brand matching fixture options.
Side Mount units do NOT include the flushometer
Smart Sense Technology™
Sloan’s SFSM flushometers are equipped with Smart Sense Technology™, which applies extended range and logic techniques to significantly reduce water usage in high-use urinal applications; such as when a continuous line of people (queue) forms. In fact, during a continuous queue, the urinal will only flush after every fifth user.
Automatic
Sloan’s SFSM flushometers are activated via multi-lobular infrared sensor. The sensor sets the flushing mechanism when the user is detected and completes the flush when the user steps away.
Manual Operation
Sloan’s SFSM flushometers can also be activated manually by pushing the black TMO button.
Hygienic
Touchless, sensor activation eliminates the need for user contact except to initiate the
True Mechanical Override Button when required, to help control the spread of infectious diseases. The 72-Hour Sentinel Flush keeps fixture fresh during periods of non-use.
Warranty
3 year (limited)
Regal 111-1.6 SFSM HW 07-14
This space for Architect/Engineer approval
Job Name
Model Specified
Variations Specified
Customer/Wholesaler
Contractor
Architect
Date
Quantity
The information contained in this document is subject to change without notice.
Single-Flush Side Mount Hardwired
Description
Exposed, AC-powered, sensor-activated, water closet flushometer with a single-flush side mount unit for top spud floor mounted or wall hung bowls.
Flush Cycle
£ Regal 111-1.6 SFSM HW Low Consumption (1.6 gpf/6.0 Lpf)
Code: 3980096
Electrical Specifications
Control Circuit
Solid State
6 VAC/7.6 VDC Input
72-Hour Sentinel Flush
Closet Range: 2-3 seconds Arming Delay
Sensor Type
Infrared Convergence Type
Object Lock Detection
Sensor Range
Factory Set at: 22-42” (559-1067 mm)
If converted to urinal range setting:
15-30” (380-762 mm)
Transformer
Sloan Part # EL-386 (Plug-In)
120 VAC Input/6 VAC Output, 50/60 Hz
(3 VA)
Sloan Part # EL-451 (Box Mount)
120 VAC Input/6 VAC Output, 50/60 Hz
(25 VA)
Indicator Lights
User in view
Valve Operating Pressure (Flowing)
25-80 PSI (172-552 kPa)
Side Mount Components
Sleeve
Assembly
Side Mount
Flange
Hardwire
Cable
Hex
Wrench
Coupling
Wrench
Flushometer
120 VAC
6 VAC
SFSM Unit
SFSM Unit
SFSM Unit
One EL-386 transformer serves one (1) SFSM closet/ urinal flushometer. One EL-451 transformer serves up to six (6)
SFSM closet/urinal flushometerd.
Specify part number and number of transformers required accordingly.
Operation
1. A continuous, invisible light beam in emitted from the object infrared sensor.
2. As the user enters the beams effective range,
22-42” (559-1067 mm), the object lock infrared sensor senses the user.
3. When the user steps away from the object lock infrared sensor, the circuit initiates the flushing cycle to flush the fixture. The
6”
(150 mm) circuit then automatically resets and is ready for the next user.
5”
(131 mm)
SENSOR WINDOW
Rough-In
EL-700-A Single-Flush Side Mount Hardwired unit shown on a Sloan 111 closet flushometer
2-1/4” MIN.
(57 mm)
7”
(178 mm)
2-3/4”
(70 mm)
6”
(131 mm)
2”
(51 mm)
7-1/2”
(191 mm)
Side Mount Hardwired Unit Dimensions
5”
(131 mm)
6”
(150 mm)
SENSOR WINDOW
Headquarters
10500 Seymour Avenue
Franklin Park, IL 60131
P: 847.671.4300 / 800.9.VALVE.9
F: 847.671.4380 / 800.447.8329
© 2014 Sloan Valve Company Regal 111-1.6 SFSM HW 07-14