Regal 111-1.6 SFSM HW Specification Sheet

Add to my manuals
2 Pages

advertisement

Regal 111-1.6 SFSM HW Specification Sheet | Manualzz

Regal

Model

®

XL

C u y

Am erican

A c

Single-Flush Side Mount Hardwired

t u y

Am erican

A c

C o mplian t

Single-Flush Side Mount Hardwired

Description

Exposed, AC-powered, sensor-activated, water closet flushometer with a single-flush side mount unit for top spud floor mounted or wall hung bowls.

Flush Cycle

£ Regal 111-1.6 SFSM HW Low Consumption (1.6 gpf/6.0 Lpf)

Code: 3980096

Variation

£ DFB Dual-Filtered Fixed Bypass Diaphragm

Specifications

Quiet, exposed, diaphragm-type, chrome plated closet flushometer with the following features:

• PERMEX ® Synthetic Rubber Diaphragm with Linear Filtered Bypass with Vortex

Cleansing Action™

• ADA Compliant AC-powered infrared side mount sensor for automatic “No Hands” operation

• Chrome plated infrared sensor housing

• Can be mounted on either left or right side of valve

• True Mechanical Override Flush button

• “User in View” flashing LED

• 72-Hour sentinel flush

• Infrared sensor range adjustment screw and reset button

• 1” IPS screwdriver Bak-Chek ® angle stop with stop plug

• Adjustable tailpiece

• High back pressure vacuum breaker flush connection with one-piece bottom hex coupling nut

• Spud coupling and flange for 1-1/2” top spud

• Sweat solder adapter with cover tube and cast wall flange with set screw

• High copper, low zinc brass castings for dezincification resistance

• No external volume adjustment to ensure water conservation

• Diaphragm, stop seat and vacuum breaker molded from PERMEX rubber compound for chloramine resistance

Valve body, tailpiece and control stop shall be in conformance with ASTM Alloy

Classification for semi-red brass. Valve shall be in compliance with the applicable sections of ASSE 1037, ASME 112.18, ASME 112.19, ANSI 117.1. Installation conforms to ADA requirements.

Accessories (specify separately)

 EL-386 120 VAC Input/6 VAC Output, 50/60 Hz (3 VA) Plug-In (will operate 1 unit)

 EL-451 120 VAC Input/6 VAC Output, 50/60 Hz (25 VA) Box Mount (will operate up to 6 units)

Fixtures

Consult Sloan for Sloan brand matching fixture options.

Side Mount units do NOT include the flushometer

Smart Sense Technology™

Sloan’s SFSM flushometers are equipped with Smart Sense Technology™, which applies extended range and logic techniques to significantly reduce water usage in high-use urinal applications; such as when a continuous line of people (queue) forms. In fact, during a continuous queue, the urinal will only flush after every fifth user.

Automatic

Sloan’s SFSM flushometers are activated via multi-lobular infrared sensor. The sensor sets the flushing mechanism when the user is detected and completes the flush when the user steps away.

Manual Operation

Sloan’s SFSM flushometers can also be activated manually by pushing the black TMO button.

Hygienic

Touchless, sensor activation eliminates the need for user contact except to initiate the

True Mechanical Override Button when required, to help control the spread of infectious diseases. The 72-Hour Sentinel Flush keeps fixture fresh during periods of non-use.

Warranty

3 year (limited)

Regal 111-1.6 SFSM HW 07-14

This space for Architect/Engineer approval

Job Name

Model Specified

Variations Specified

Customer/Wholesaler

Contractor

Architect

Date

Quantity

The information contained in this document is subject to change without notice.

Single-Flush Side Mount Hardwired

Description

Exposed, AC-powered, sensor-activated, water closet flushometer with a single-flush side mount unit for top spud floor mounted or wall hung bowls.

Flush Cycle

£ Regal 111-1.6 SFSM HW Low Consumption (1.6 gpf/6.0 Lpf)

Code: 3980096

Electrical Specifications

Control Circuit

Solid State

6 VAC/7.6 VDC Input

72-Hour Sentinel Flush

Closet Range: 2-3 seconds Arming Delay

Sensor Type

Infrared Convergence Type

Object Lock Detection

Sensor Range

Factory Set at: 22-42” (559-1067 mm)

If converted to urinal range setting:

15-30” (380-762 mm)

Transformer

Sloan Part # EL-386 (Plug-In)

120 VAC Input/6 VAC Output, 50/60 Hz

(3 VA)

Sloan Part # EL-451 (Box Mount)

120 VAC Input/6 VAC Output, 50/60 Hz

(25 VA)

Indicator Lights

User in view

Valve Operating Pressure (Flowing)

25-80 PSI (172-552 kPa)

Side Mount Components

Sleeve

Assembly

Side Mount

Flange

Hardwire

Cable

Hex

Wrench

Coupling

Wrench

Flushometer

120 VAC

6 VAC

SFSM Unit

SFSM Unit

SFSM Unit

One EL-386 transformer serves one (1) SFSM closet/ urinal flushometer. One EL-451 transformer serves up to six (6)

SFSM closet/urinal flushometerd.

Specify part number and number of transformers required accordingly.

Operation

1. A continuous, invisible light beam in emitted from the object infrared sensor.

2. As the user enters the beams effective range,

22-42” (559-1067 mm), the object lock infrared sensor senses the user.

3. When the user steps away from the object lock infrared sensor, the circuit initiates the flushing cycle to flush the fixture. The

6”

(150 mm) circuit then automatically resets and is ready for the next user.

5”

(131 mm)

SENSOR WINDOW

Rough-In

EL-700-A Single-Flush Side Mount Hardwired unit shown on a Sloan 111 closet flushometer

2-1/4” MIN.

(57 mm)

7”

(178 mm)

2-3/4”

(70 mm)

6”

(131 mm)

2”

(51 mm)

7-1/2”

(191 mm)

Side Mount Hardwired Unit Dimensions

5”

(131 mm)

6”

(150 mm)

SENSOR WINDOW

Headquarters

10500 Seymour Avenue

Franklin Park, IL 60131

P: 847.671.4300 / 800.9.VALVE.9

F: 847.671.4380 / 800.447.8329

© 2014 Sloan Valve Company Regal 111-1.6 SFSM HW 07-14