Split Systems - fujitsu general

Split Systems - fujitsu general
020
SPLIT
022 PRODUCT LINEUP
026 Feature Explanation & Summary
030 Wall Mounted Flagship Range Series
032 Wall Mounted Designer Range Series
• High Spec & Design
• High COP
038 Wall Mounted Standard Range Series
• High Efficiency & Comfort
• Comfort for Large Room
042 Wall Mounted Standard Range Series
044 Wall Mounted ECO Range Series
046 Floor
048 Cassette Compact 4-way Flow Series
050 Cassette Circular Flow Series
052 Cassette 4-way Flow Series
054 Bulkhead Duct
056 Slim Duct
058 Medium Static Pressure Duct
062 High Static Pressure Duct
066 Big Duct
068 Floor/Ceiling
070 Ceiling
021
PRODUCT LINEUP
SPLIT Indoor Units
Type
Series
BTU
9
12
ASYG09KXCA
ASYG12KXCA
ASYG09KGCA*
ASYG12KGCA*
ASYG09LTCA
ASYG12LTCA
ASYG07LUCA
ASYG09LUCA
ASYG12LUCA
ASYG07LMCE
ASYG09LMCE
ASYG12LMCE
ASYG09LLCE
ASYG12LLCE
AGYG09LVCA
AGYG12LVCA
7
NEW
Flagship Range Series
Page 030
NEW
Designer Range Series
High Spec & Design
Page 032
ASYG07KGCA*
Designer Range Series
High Spec & Design
Page 034
Designer Range Series
High COP
Page 036
NEW
Standard Range Series
High Efficiency & Comfort
Page 038
Standard Range Series
Comfort for Large Room
Page 040
Standard Range Series
New Design & Large Capacity
Page 042
NEW
ECO Range Series
Compact & Comfort
Page 044
Floor
Compact & Comfort
Page 046
022
FUJITSU GENERAL (Euro) GmbH participates in
the ECP programme for AIR CONDITIONERS.
Check ongoing validity of certificate:
www.eurovent-certification.com or using
www.certiflash.com
* Models so marked are not Eurovent certified,
at time of print.
BTU
14
18
24
ASYG18LFCA
ASYG24LFCC
30
36
ASYG14KGCA*
ASYG14LUCA
ASYG14LMCE
ASYG30LMTA
ASYG36LMTA
AGYG14LVCA
023
PRODUCT LINEUP
SPLIT Indoor Units
Type
BTU
Series
12
14
18
24
AUYG12LVLB
AUYG14LVLB
AUYG18LVLB
AUYG24LVLA
AUXG18LRLB
AUXG24LRLB
Compact
4-way Flow Series
Compact & Comfort
Page 048
Cassette
Page 048~
Circular Flow Series
Comfort for Large Room
Page 050
4-way Flow Series
Comfort for Large Room
Page 052
NEW
Bulkhead Duct
Page 054
ARYG12LSLAP*
ARYG14LSLAP*
ARYG18LSLAP*
ARYG12LLTB
ARYG14LLTB
ARYG18LLTB
ARYG14LHTBP
ARYG18LHTBP
Slim Duct
Page 056
Medium
Static Pressure Duct
Compact & Comfort
Page 058
Duct
Page 054~
NEW
NEW
ARYG12LHTBP
ARYG24LHTBP
Medium
Static Pressure Duct
Standard
Page 060
ARYG24LMLA
High
Static Pressure Duct
Page 062
NEW
Big Duct
Page 066
Floor/Ceiling
Comfort & Dual Design
Page 068
Ceiling
Comfort a Large Room
Page 070
024
ABYG18LVTB
ABYG24LVTA
FUJITSU GENERAL (Euro) GmbH participates in
the ECP programme for AIR CONDITIONERS.
Check ongoing validity of certificate:
www.eurovent-certification.com or using
www.certiflash.com
* Models so marked are not Eurovent certified,
at time of print.
30
36
45
BTU
54
AUXG30LRLB
AUXG36LRLB
AUXG45LRLB
AUXG54LRLB
AUYG30LRLE
AUYG36LRLE
AUYG36LRLA
AUYG45LRLA
AUYG54LRLA
ARYG30LHTBP
ARYG36LHTBP
ARYG45LHTBP
ARYG54LHTBP
ARYG30LMLE
ARYG36LMLE
ARYG36LMLA
ARYG45LMLA
ARYG45LHTA
ABYG30LRTE
ABYG36LRTE
ARYG36LRTA
ABYG45LRTA
ARYG54LHTA
60
ARYG60LHTA
72
90
ARYC72LHTA
ARYC90LHTA
Future Release
Future Release
ARYG72LHTA*
ARYG90LHTA*
ABYG54LRTA
025
Feature Explanation & Summary
SPLIT Feature Explanation
Energy Saving Function
Dual side fans
Save human sensor
Economy mode
The comfortable space can be created with
Hybrid Airflow, which combines different
temperatures of air current and velocities.
Human sensor detects the movement of people
in the room to operate the energy saving
function / operation.
Thermostat setting automatically changes
according to the temperature to avoid
unnecessary cooling and heating.
Room temperature set point limitation
Set temperature auto return
The minimum and maximum temperature range
can be set giving further energy saving while
considering the comfort of the occupants.
The setting temperature automatically returns to
the previously set temperature.
Comfortable Function
Powerful heating
Power diffuser
Powerful mode
Keeping the rated heating capacity even when the
outdoor ambient temperature is -7°C.
An additional louvre that opens based on
monitoring sensors to quickly enhance
immediate comfort needs.
Operation at maximum air flow and compressor
speed, and quickly makes the room comfortable.
10°C HEAT operation
Low noise mode
Auto-changeover
The room temperature can be set to go no lower
than 10°C, thus ensuring that the room does not
get too cold when not occupied.
Sound noise level of outdoor unit can be
selected.
The unit automatically switches between heating
and cooling modes based on your temperature
setting and the room temperature.
Up/down swing flaps
Double swing automatic
Automatic fan speed
The up/down flaps automatically swing up and
down.
Complex swing action of flaps enables
automatically to swing both horizontal and
vertical directions.
The micro-computer automatically adjusts the
airflow effectively to follow the changes of room
temperature.
Fresh air intake
Server room operation
Fresh air can be taken in by a fan which can be
connected using external control unit.
Interlock operation is possible by connecting 2
indoor units even in the low temperature.
Auto off timer
Sleep timer
Program timer
Automatically stops operation when a fixed time
has elapsed from the start of operation.
The micro-computer gradually changes the
room temperature automatically to afford a
comfortable night's sleep.
This digital timer allows selection of one of four
options:
ON, OFF, ON » OFF or OFF « ON.
Weekly timer
Weekly + setback timer
Filter sign
Different ON-OFF times can be set for each day.
Weekly + Setback timer can set temperature for
two time spans and for each day of the week.
Indicates the filter cleaning period by lamp.
External error output
External ON/OFF input
Wireless LAN control
Auto restart
In the event of a temporary power failure, the air
conditioner will automatically restart in the same
operating mode as before, once power supply is
restored.
Convenient Function
The exclusive Wi-Fi adaptor enables to operate
the air conditioner by smartphone or tablet PC
from outside.
Clean Function
Plasma air clean
Filter auto clean
Ion deodorisation filter
The electrostatic precipitator removes dust
particles such as pollens and house dust. It is
washable so can be kept clean.
The dust collected by the air filter is automatically
removed. A routine disposal of the dust stored in
the dust box is necessary.
The filter deodorises by powerfully
decomposing absorbed odors using the
oxidising and reducing effects of ions
generated by the ultra-fine-particle ceramic.
Apple-catechin filter
Washable panel
The Apple-catechin filter uses static electricity to
clean fine particles and dust in the air.
Since the front panel is easy to remove,
maintenance is also easy.
Installation
026
Drain pump as standard
Blue fin
All DC models
i-PAM control models
V-PAM control models
i-PAM inverter control is a technology which
reduces loss by adjusting the current waveform to
a better sine waveform.
V-PAM inverter control reduces the effects of
magnetic flux and increases the maximum speed
and efficiency of the compressor by vector control
technology.
SPLIT Feature Summary
Wall Mounted
Type
Flagship
Range
Model No.
Designer Range
ASYG09/12 ASYG07/09/12/ ASYG09/12
KXCA
14KGCA
LTCA
Standard Range
ASYG07/09/
12/14LUCA
ASYG07/09/
12/14LMCE
ASYG18/30
LFCA,
ASYG24LFCC
ECO Range
ASYG30/36
LMTA
ASYG07/09/
12LLCE
Floor
AGYG09/12/
14LVCA
Dual side fans
Energy Saving Function
Save human sensor
Economy mode
Room temperature set
point limitation
Set temperature auto
return
Server room operation
Powerful heating
Power diffuser
Powerful mode
Comfortable Function
10°C HEAT operation
Low noise mode
Auto-changeover
Up/down swing flaps
Double swing automatic
Automatic fan speed
Auto restart
Fresh air intake
Auto off timer
Sleep timer
Program timer
Convenient Function
Weekly timer
Weekly + setback timer
Filter sign
External error output
External ON/OFF input
Wireless LAN control
Plasma air clean
Clean Function
Filter auto clean
Ion deodorisation filter
Apple-catechin filter
Washable panel
Installation
Drain pump as standard
Blue fin
: Optional function
027
Feature Explanation & Summary
SPLIT Feature Explanation
Energy Saving Function
Save human sensor
Save & Stop human sensor
Economy mode
Human sensor detects the movement of people
in the room to operate the energy saving
function / operation.
Human sensor (option) detects movement of
people in the room and decides whether to save
energy or stop the unit.
Thermostat setting automatically changes
according to the temperature to avoid
unnecessary cooling and heating.
Room temperature set point limitation
Set temperature auto return
The minimum and maximum temperature range
can be set giving further energy saving while
considering the comfort of the occupants.
The setting temperature automatically returns to
the previously set temperature.
Comfortable Function
Auto-changeover
Up/down swing flaps
Sound noise level of outdoor unit can be
selected.
The unit automatically switches between heating
and cooling modes based on your temperature
setting and the room temperature.
The up/down flaps automatically swing up and
down.
Double swing automatic
Automatic fan speed
Auto restart
Complex swing action of flaps enables
automatically to swing both horizontal and
vertical directions.
The micro-computer automatically adjusts the
airflow effectively to follow the changes of room
temperature.
In the event of a temporary power failure, the air
conditioner will automatically restart in the same
operating mode as before, once power supply is
restored.
Connectable fresh air duct
Fresh air intake
Connectable distributing duct
Outside air can be introduced by attaching
Locally purchased duct to fresh air knockout and
optional part.
Fresh air can be taken in by a fan which can be
connected using external control unit.
Systems are capable of attaching Locally
purchased branch ducts distributing the airflow.
Individual airflow direction control
10°C HEAT operation
Each louver of 4-way Cassette type can be
controlled individually and provides comfortable
airflow.
The room temperature can be set to go no lower
than 10°C, thus ensuring that the room does not
get too cold when not occupied.
Low noise mode
Convenient Function
Auto off timer
Sleep timer
Program timer
Automatically stops operation when a fixed
time has elapsed from the start of operation.
The micro-computer gradually changes the
room temperature automatically to afford a
comfortable night's sleep.
This digital timer allows selection of one of four
options:
ON, OFF, ON » OFF or OFF « ON.
Weekly timer
Weekly + setback timer
Filter sign
Different ON-OFF times can be set for each day.
Weekly + Setback timer can set temperature for
two time spans and for each day of the week.
Indicates the filter cleaning period by lamp.
External error output
External ON/OFF input
Wireless LAN control
The exclusive Wi-Fi adaptor enables to operate
the air conditioner by smartphone or tablet PC
from outside.
Clean Function
Ion deodorisation filter
Apple-catechin filter
Washable panel
The filter deodorises by powerfully
decomposing absorbed odors using the
oxidising and reducing effects of ions
generated by the ultra-fine-particle ceramic.
The Apple-catechin filter uses static electricity to
clean fine particles and dust in the air.
Since the front panel is easy to remove,
maintenance is also easy.
Drain pump as standard
Blue fin
i-PAM control models
V-PAM control models
i-PAM inverter control is a technology which
reduces loss by adjusting the current waveform
to a better sine waveform.
V-PAM inverter control reduces the effects of
magnetic flux and increases the maximum
speed and efficiency of the compressor by
vector control technology.
Long life filter
Installation
Automatic airflow adjustment
Automatically detects required airflow in each
application case and adjusts the volume.
All DC models
028
SPLIT Feature Summary
Cassette
Type
Compact
4-way Flow
Model No.
Circular
Flow
Duct
4-way Flow
AUYG12/14/
AUYG30/36
AUXG18/24/
18LVLB,
LRLE,
30/36/45/
AUYG22/24
AUYG36/45/
54LRLB
LVLA
54LRLA
Mini
Slim
ARYG
12/14/18
LSLAP
ARYG
12/14/18
LLTB
Medium Static Pressure
High Static High Static
Pressure
Pressure
ARYG22/
ARYG12/14/
24/36/45
18/24/30/ ARYG45/54/ ARYC72/90
LMLA,
LHTA
36/45/54
60LHTA
ARYG30/36
LHTBP
LMLE
Big
Floor/
Ceiling
Ceiling
ABYG18
ABYG30/36
ARYG72/90
LVTB,
LRTE,
LHTA
ABYG22/24 ABYG36/45/
LVTA
54LRTA
Save human sensor
Energy Saving Function
Save & Stop human
sensor
Economy mode
Room temperature set
point limitation
Set temperature auto
return
10°C HEAT operation
Low noise mode
(60)
(45/54)
(45)
(36LMLA)
(45/54)
(45/54)
(36LRTA)
Auto-changeover
Comfortable Function
Up/down swing flaps
Double swing automatic
Automatic fan speed
Auto restart
Connectable fresh
air duct
Fresh air intake
Connectable
distributing duct
Individual airflow
direction control
Auto off timer
Sleep timer
(60)
Program timer
(60)
Convenient Function
Weekly timer
Weekly + setback timer
Filter sign
External error output
External ON/OFF input
Wireless LAN control
Ion deodorisation filter
Clean Function
Apple-catechin filter
Washable panel
Long life filter
(60)
Installation
Automatic airflow
adjustment
Drain pump as standard
Blue fin
(30/36/45/54)
(45/54)
(30/36/45/54)
(45)
: Optional function
029
SPLIT
NEW
Wall Mounted Flagship Range
Features
Comfortable airflow control to prevent the
body from being exposed to airflow
The comfortable space can be created
with Hybrid Airflow, which combines
different temperatures of air current
and velocities.
*1
*1: Announced 2012. In room air conditioner for the home (Our company’s investigation)
Filter Auto Clean
*2
Main brush
Dust on the filter is automatically removed to
prevent power from being wasted by the clogged
filter.
Dust
Self-cleaning brush
Dust collection box
Dust is stored in the collection box.
*2: Announced 2002. In room air conditioner for the home (our company’s investigation)
Plasma Air Clean
Air is cleaned with an electric dust collecting technology.
Pollen, house dust and other tiny pollutants are collected and
removed with static electricity.
Electrostatic dust collector
Human Sensor
Rank
The Human sensor detects movement of people in a room and operates at reduced capacity
when people leave the room. When people return to the room, the system automatically
returns to the previous room settings.
A pers
erson
on lea
leaves
ves the
th
he room
room
oo
030
Energy
Ene
rgy
gy sa
savin
ving
vin
g oper
oper
p ati
ation
on
n
A+++
SEER
SCOP
8.5 5.1
*1
*1: All classes
Bacck to
to orig
origina
inall oper
oper
perati
ation
ati
o
on
*1
Model: ASYG09KXCA / ASYG12KXCA
Wireless R.C.
Wireless
LAN Interface
Specifications
Model No.
Indoor unit
ASYG09KXCA
ASYG12KXCA
Outdoor unit
AOYG09KXCA
AOYG12KXCA
Power Source
Capacity
UK Total/Sensible Cooling
Input Power
EER
COP
Pdesign
SEER
SCOP
(QHUJ\(IÀFLHQF\
Class
Max. Operating Current
Annual Energy
Consumption
Single-phase, ~230V, 50Hz
Cooling
Heating
Cooling/Heating
Cooling
Heating
Cooling/Heating(-10°C)
Cooling
Heating (Average)
Cooling
Heating (Average)
Cooling/Heating
Cooling
Heating
Moisture Removal
kW
W/W
kW
W/W
A
kWh/a
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
Indoor(Cooling/Heating)
High
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor (Cooling)
$LUÁRZ5DWH
High
Indoor / Outdoor (Heating)
Net Dimensions
HxWxD
Weight
2.5 (0.6-3.5)
3.6 (0.6-7.1)
TBC
0.460/0.630
5.45
5.72
2.5/3.4
8.50
5.10
A+++
A+++
8.5/14.0
103
934
1.1
46/42/38/28
48/43/39/30
40/41
58/62
53/57
670/1,975
810/1,820
kW
Indoor
Outdoor
Suggested MCB Size
Connection Pipe Diameter (Gas / Liquid)
Max Pipe Length (Pre-Charge)
Max Height Difference
Cooling
Operation Range
Heating
Type
Refrigerant
Charge
Additional Charge
System List Price
dB(A)
m3/h
mm
kg
mm
kg
Amp
Inch
3.4 (0.6-5.3)
5.0 (0.6-9.0)
TBC
0.670/1.020
5.09
4.90
3.4/3.5
8.50
5.10
A+++
A+++
9.0/16.0
140
961
1.2
46/42/38/28
48/43/39/30
44/43
58/62
57/57
670/2,230
810/1,975
293×786×378
20
704×820×315
41
16
3/8 & 1/4
15 (15)
10
-10 to 43
-15 to 24
R32
1300
0
m
°CDB
g
g/m
£
2120
2461
Dimensions
(Unit : mm)
378
Front view
Side view
65*
293
786
*Dimensions in case of air flowing downward
031
SPLIT
NEW
Wall Mounted Designer Range
High Spec & Design
Features
Slim & stylish square design
Slim and stylish square design is realised by high density multipath heat exchanger and high efficiency wind blower.
215mm
*1
High seasonal efficiency
Human sensor catches movements of people in a room, and
operates with lower capacity when people leave the room.
When people come back to the room, it automatically returns to
previous operating mode.
Rank
A+++
Human sensor
H
SEER
SCOP
8.5 5.1
*1
*1: 07, 09, 12 class
Silent model
19dB(A)
Smartphone Control (Option)
Easy air conditioner control from inside or outside the house and
office using the Smartphones, Tablets, and PC.
(Supplied loose as standard for site installation).
Wireless LAN Interface
The exclusive Wi-Fi adaptor
enables to operate the air
conditioner by smartphone or
tablet PC from outside.
032
*1
Model: ASYG07KGCA / ASYG09KGCA / ASYG12KGCA / ASYG14KGCA
Wireless R.C.
Specifications
Model No.
Indoor unit
ASYG07KGCA
ASYG09KGCA
ASYG12KGCA
A
ASYG14KGCA
Outdoor unit
AOYG07KGCA
AOYG09KGCA
AOYG12KGCA
14KGCA
AOYG14KGCA
Power Source
Capacity
UK Total/Sensible Cooling
Input Power
EER
COP
Pdesign
SEER
SCOP
(QHUJ\(IÀFLHQF\
Class
Max. Operating Current
Annual Energy
Consumption
Cooling
Heating
Cooling/Heating
Cooling
Heating
Cooling/Heating(-10°C)
Cooling
Heating (Average)
Cooling
Heating (Average)
Cooling/Heating
Cooling
Heating
Moisture Removal
kW
W/W
kW
W/W
2.0
2.5
TBC
0.440/0.500
4.55
5.00
2.00/2.30
8.50
5.10
A+++
A+++
A
kWh/a
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
Indoor(Cooling/Heating)
High
Sound Power Level
Outdoor(Cooling/Heating) High
$LUÁRZ5DWH
Indoor / Outdoor
High
Net Dimensions
HxWxD
Weight
kW
Indoor
Outdoor
Suggested MCB Size
ameter (Gas / Liquid)
Connection Pipe Diameter
Max Pipe Length
gth (Pre-Charge)
Max Height
ght Difference
Cooling
Operation Range
Heating
Type
Refrigerant
Charge
Additional Charge
System
Sys
List Price
dB(A))
m3/h
mm
kg
mm
kg
Amp
Inch
te
a
t
n
43/ / /
43/ / /
Single-phase, ~230V, 50Hz
2.5
3.4
2.8
4.0
TBC
TBC
/0.990
0.555/0.560
0.805/0.990
4.50
4.22
5.00
4.04
2.50/2.40
3.40/2.50
8.50
8.50
5.10
5.10
0
5
A+++
A+++
A+++
A+++
e
v
ti
43/ / /
43/ / /
43/ / /
43/ / /
270×834×215
540×799×290
TBC
TBC
TBC
TBC
R32
890
0
R32
940
0
3/8 & 1/4
20 (15)
15
-10 to 46
-15 to 24
m
°CDB
g
g/m
£
4.2
5.4
TBC
1
1
1.175/1.350
3.57
4.00
4.20/4.00
7.10
4.30
A++
A+
R32
770
0
R32
770
0
Future Release
Optional parts
Wired Remote Controller:
UTYRNRYZ2
£161
Simple Remote Controller: UTYRSNYM
£83
Communication kit:
£90
UTYXCBXZ2
Dimensions
(Unit : mm)
033
SPLIT
Wall Mounted Designer Range
High Spec & Design
Features
Thin & Slim design
Big open panel and High density multi path heat exchanger
Thin and slim design is realised by high density multi-path heat
exchanger and high efficiency fan.
Large intake
Refrigerant
Ø5 mm
Open
panel
H282 X W870 X D185
185 mm
Large fan
Distributor 4-path
20 mm
Human sensor
90°
Human sensor catches movements of people in a room, and operates with lower
capacity when people leave the room. When people come back to the room, it
automatically returns to previous operating mode.
100°
6m
6m
3.0
2.0
Weekly timer can be easily set by wireless
remote controller. ON, OFF can be set up to 4
times in 1 day and up to 28 times in 1 week.
For other modes, program timer and sleep
timer can be also selected by one push.
Current model
1.0
-25
3 Mode timer
(Weekly/Program/Sleep)
3.5-kW class
4.0
New model
Heating Capacity
(kW)
Rated heating capacity is maintained up to an outdoor temperature
lower than -7 °C. This new model can operate even at -20 °C low outdoor
temperature.
2.5-kW class
4.0
Heating Capacity
(kW)
Powerful heating
-20
-15 -10 -7 -5
0
5
Outdoor Temperature (°C)
3.0
Current model
2.0
1.0
10
-25
-20
-15 -10 -7 -5
0
5
Outdoor Temperature (°C)
Low ambient operation
Cooling
43°C
Heating
24°C
-20°C
at Heating
-10°C
034
New model
-20°C
10
Model: ASYG09LTCA / ASYG12LTCA
For ASYG09LTCA
For ASYG12LTCA
Wireless R.C.
Specifications
Model No.
Indoor unit
ASYG09LTCA
Outdoor unit
AOYG09LTC
Power Source
AOYG12LTC
Single-phase, ~230V, 50Hz
Cooling
Heating
Nominal Capacity
UK Total/Sensible Cooling
Power Consumption
EER
COP
Pdesign
SEER
SCOP
ASYG12LTCA
Cooling/Heating
Cooling
Heating
Cooling/Heating(-10°C)
Cooling
Heating (Average)
Cooling
Heating (Average)
Cooling
Heating
Class
Annual Energy
Consumption
kW
kW
W/W
kW
W/W
kWh/a
Moisture Removal
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
dB(A)
Indoor(Cooling/Heating)
High
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
Airflow Rate
mm
Indoor
Net Dimensions
kg
HxWxD
mm
Weight
Outdoor
kg
Remote Controller Type
Interconnecting Cable (Suggested cable size 1.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling/Heating
Amp
Power Supply To
Connection Pipe Diameter (Gas / Liquid)
Inch
Max Pipe Length (Factory Gas Charge Pipe Length)
m
Max Height Difference
Type
Refrigerant
Charge
g
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
System List Price
£
2.50 (0.90-3.50)
3.20 (0.90-5.40)
2.42/1.59
0.55/0.66
4.95
4.85
2.50/3.00
8.50
4.60
A+++
A++
103
912
1.30
42/36/32/21
42/37/32/21
48/50
59/61
63/65
800/1700
282×870×185
9.5
540×790×290
33
Wireless
3.50 (1.10-4.00)
4.00 (0.90-6.50)
3.40/2.24
0.85/0.91
4.12
4.40
3.50/4.00
8.50
4.60
A+++
A++
144
1217
1.80
43/37/32/21
43/38/32/21
48/49
60/62
64/65
850/2050
282×870×185
9.5
620×790×290
40
Wireless
3 core + Earth
10
2.60/3.30
10
4.00/4.30
Outdoor Unit
3/8 & 1/4
20 (15)
15
R410A
1,050
20
-10 to 43
-20 to 24
1030
3/8 & 1/4
20 (15)
15
R410A
1,200
20
-10 to 43
-20 to 24
1198
Optional parts
Wired Remote Controller:
Simple Remote Controller:
External Connect Kit:
Modbus Interface:
KNX Interface:
WiFi Interface:
Communication kit:
UTYRVNYM
UTYRSNYM
UTYXWZXZ5
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
UTYTWBXF
£104
£83
£9
£234
£265
£234
£90
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Refer to page 102 for accessory combinations)
Dimensions
282
100
or more
337
55
(Unit : mm)
870
185
035
SPLIT
Wall Mounted Designer Range
High COP
Features
Thin & Slim design
Thin and slim design is realised by Ø5 mm heat exchanger and
high efficiency fan.
Big open panel and High density multi path heat exchanger
Large intake
Refrigerant
Ø5 mm
Open
panel
H282 X W870 X D185
185 mm
Large fan
Temperature
Powerful operation
20 minutes continuous operation by maximum airflow and maximum
compressor speed is possible. Rapid cooling and heating makes the
room comfortable quickly.
Distributor 4-path
20 mm
Setting temp.
Normal mode
Powerful operation mode
Time
3 Mode timer (Weekly/Program/Sleep)
Weekly timer can be easily set by wireless remote controller. ON, OFF can be set
up to 4 times in 1 day and up to 28 times in 1 week. For other modes, program
timer and sleep timer can be also selected by one push.
10°C HEAT Operation
The room temperature can be set
to go no lower than 10°C, thus
ensuring that the room does not
get too cold when not occupied.
*Only available with Wireless RC.
“10°C HEAT” Button ON
Low ambient operation
Cooling
20°C
10°C
46°C (07/09 model)
43°C (12/14 model)
Indoor unit operation START
Heating
24°C
-15°C
at Heating
-10°C
036
-15°C
Model: ASYG07LUCA / ASYG09LUCA / ASYG12LUCA / ASYG14LUCA
For ASYG07/09LUCA
For ASYG12/14LUCA
Wireless R.C.
Specifications
Model No.
Indoor unit
ASYG07LUCA
ASYG09LUCA
ASYG12LUCA
ASYG14LUCA
Outdoor unit
AOYG07LUCA
AOYG09LUCB
AOYG12LUC
AOYG14LUC
Power Source
Cooling
Heating
Nominal Capacity
UK Total/Sensible Cooling
Power Consumption
EER
COP
Pdesign
SEER
SCOP
Cooling/Heating
Cooling
Heating
Cooling/Heating(-10°C)
Cooling
Heating (Average)
Cooling
Heating (Average)
Cooling
Heating
Class
Annual Energy
Consumption
2.0 (0.5-3.0)
3.0 (0.5-4.0)
1.94 / 1.30
0.46/0.66
4.35
4.55
2.00/2.60
7.20
4.10
A++
A+
97
887
1.00
38/35/31/21
38/35/31/21
46/46
57/59
58/58
680/1,720
282×870×185
9.5
540×660×290
23
Wireless
kW
kW
W/W
kW
W/W
kWh/a
Moisture Removal
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
dB(A)
Indoor(Cooling/Heating)
High
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
Airflow Rate
mm
Indoor
Net Dimensions
kg
HxWxD
mm
Weight
Outdoor
kg
Remote Controller Type
Interconnecting Cable (Suggested cable size 1.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling/Heating
Amp
Starting Current
Amp
Power Supply To
Connection Pipe Diameter (Gas / Liquid)
Inch
Max Pipe Length (Factory Gas Charge Pipe Length)
m
Max Height Difference
Type
Charge
g
Refrigerant
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
System List Price
£
10
6.0/7.5
3.40
3/8 & 1/4
20 (15)
15
R410A
700
20
-10 to 46
-15 to 24
870
Single-phase, ~230V, 50Hz
2.5 (0.5-3.2)
3.5 (0.9-4.0)
3.2 (0.5-4.2)
4.0 (0.9-5.6)
2.42 / 1.59
3.40 / 2.24
0.55/0.68
0.91/0.93
4.50
3.87
4.71
4.30
2.50/2.80
3.50/3.90
7.10
7.05
4.10
4.00
A++
A++
A+
A+
123
174
956
1363
1.30
1.80
42/36/32/21
43/37/32/21
42/37/32/21
43/38/32/21
48/48
50/50
59/61
60/62
60/60
65/65
800/1,720
850/1,940
282×870×185
282×870×185
9.5
9.5
540×660×290
540×790×290
33
25
Wireless
Wireless
3 Core + Earth
10
10
6.0/7.5
6.5/9.0
3.40
4.70
Outdoor
3/8 & 1/4
3/8 & 1/4
20 (15)
20 (15)
15
15
R410A
R410A
850
1,050
20
20
-10 to 46
-10 to 43
-15 to 24
-15 to 24
931
1082
4.2 (0.9-5.0)
5.4 (0.9-6.0)
4.07 / 2.73
1.24/1.38
3.40
3.91
4.20/4.80
6.78
4.00
A++
A+
217
1677
2.10
45/40/33/25
45/40/34/27
50/50
60/64
65/65
900/1,940
282×870×185
9.5
540×790×290
34
Wireless
16
9.0/10.5
6.30
1/2 & 1/4
20 (15)
15
R410A
1,050
20
-10 to 43
-15 to 24
1246
Optional parts
Wired Remote Controller:
Simple Remote Controller:
External Connect Kit:
Modbus Interface:
KNX Interface:
WiFi Interface:
Communication kit:
UTYRVNYM
UTYRSNYM
UTYXWZXZ5
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
UTYTWBXF
£104
£83
£9
£234
£265
£234
£90
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Refer to page 102 for accessory combinations)
Dimensions
282
100
or more
337
55
(Unit : mm)
870
185
037
SPLIT
NEW
Wall Mounted Standard Range
High Efficiency & Comfort
Features
High efficient compact design
High density heat exchanger
Making the tube thin:
7 mm 5 mm
Increase of heat exchanger
volume by high density and
adopting sub heat exchanger
Even temperature
Improved heat
exchanger effectiveness
More comfort airflow
Horizontal airflow does not blow cool air directly at the
occupants in the room.
Powerful operation
Low noise mode for
outdoor unit
Setting temp.
Low noise mode of outdoor
unit can be selected by
wireless remote controller.
Normal mode
Powerful operation mode
Time
038
3Down
dB
Ghbl^
20 minutes continuous
operation by maximum airflow
and maximum compressor
speed is possible. Rapid
cooling and heating makes the
room comfortable quickly.
Temperature
Vertical airflow provides powerful floor level heating
Noise level Max.
power operating
Ehpghbl^
fh]^
Model: ASYG07LMCE / ASYG09LMCE / ASYG12LMCE / ASYG14LMCE
For AOYG07/09/12LMCE
Wireless R.C.
For AOYG14LMCE
Specifications
Model No.
Indoor unit
ASYG07LMCE
ASYG09LMCE
ASYG12LMCE
ASYG14LMCE
Outdoor unit
AOYG07LMCE
AOYG09LMCE
AOYG12LMCE
AOYG14LMCE
Power Source
Nominal Capacity
UK Total/Sensible Cooling
Power Consumption
EER
COP
Pdesign
SEER
SCOP
Class
Annual Energy
Consumption
Cooling
Heating
Cooling/Heating
Cooling
Heating
Cooling/Heating(-10°C)
Cooling
Heating (Average)
Cooling
Heating (Average)
Cooling
Heating
Moisture Removal
kW
kW
W/W
kW
W/W
kWh/a
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
dB(A)
Indoor(Cooling/Heating)
High
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
Airflow Rate
mm
Indoor
Net Dimensions
kg
HxWxD
mm
Weight
Outdoor
kg
Remote Controller Type
Interconnecting Cable (Suggested cable size 1.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling/Heating
Amp
Starting Current
Amp
Power Supply To
Connection Pipe Diameter (Gas / Liquid)
Inch
Max Pipe Length (Factory Gas Charge Pipe Length)
m
Max Height Difference
Type
Charge
g
Refrigerant
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
System List Price
£
2.0(0.5-3.0)
3.0(0.5-3.4)
1.94/1.30
0.465/0.685
4.30
4.38
2.00/2.30
6.80
4.10
A++
A+
103
786
1.00
43/40/32/21
43/38/33/22
45/45
59/59
58/56
750/1670
270×870×204
8.5
535×663×293
21
Wireless
Single-phase,~230V,50Hz
2.5(0.5-3.2)
3.4(0.9-3.9)
3.2(0.5-4.0)
4.0(0.9-5.3)
2.42/1.59
3.30/2.14
0.65/0.73
0.97/1.02
3.85
3.50
4.38
3.92
2.50/2.40
3.40/3.50
7.00
7.00
4.10
4.00
A++
A++
A+
A+
170
125
820
1225
1.30
43/40/32/21
43/38/33/22
45/45
59/59
58/56
750/1670
270×870×204
8.5
535×663×293
21
Wireless
4.0(0.9-4.4)
5.0(0.9-6.0)
3.87/2.52
1.135/1.365
3.52
3.66
4.00/3.90
6.90
4.00
A++
A+
203
1365
1.80
43/40/32/21
43/38/33/22
50/50
59/59
61/61
750/1830
270×870×204
8.5
535×663×293
26
Wireless
2.10
44/40/33/25
44/40/35/27
50/50
60/60
65/65
750/1800
270×870×204
8.5
540×790×290
34
Wireless
10
6.50/9.00
4.80
16
9.00/10.50
6.30
3/8 & 1/4
20(15)
15
R410A
850
20
-10 to 43
-15 to 24
743
1/2 & 1/4
20(15)
15
R410A
1050
20
-10 to 43
-15 to 24
855
3 Core + Earth
10
6.00/7.50
3.30
10
6.00/7.50
3.50
Outdoor
3/8 & 1/4
20(15)
15
R410A
700
20
-10 to 43
-15 to 24
620
3/8 & 1/4
20(15)
15
R410A
700
20
-10 to 43
-15 to 24
653
Optional parts
Wired Remote Controller:
Simple Remote Controller:
External Connect Kit:
Modbus Interface:
KNX Interface:
WiFi Interface:
Communication kit:
UTYRVNYM
UTYRSNYM
UTYXWZXZ5
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
UTYTWBXF
£104
£83
£9
£234
£265
£234
£90
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Must use with Communication Kit below)
(Refer to page 102 for accessory combinations)
Dimensions
(Unit : mm)
039
SPLIT
Wall Mounted Standard Range
(18/30)
Comfort for Large Room
(24)
(30)
Features
“Vertical airflow” provides powerful floor
level heating
Ý&
2XWVLGHDLUFRQGLWLRQVÝ&
Operation contents: Heating,
6HWWHPSHUDWXUH0D[VHWWHPSÝ&,
airflow Hi, Air direction downward and front 33
46o
32
31
29
Power diffuser (full open)
“Horizontal airflow” does not blow cool
air directly at the occupants in the room
Ý&
Power diffuser
2XWVLGHDLUFRQGLWLRQVÝ&
2SHUDWLRQFRQWHQWV&RROLQJ
6HWWHPSHUDWXUH0LQVHWWHPSÝ&
DLUIORZ+L$LUGLUHFWLRQXSZDUGDQGIURQW
15
16
17
18
Air conditioner filter features
Ion Deodorisation Filter
The filter deodorises by powerfully decomposing absorbed odors using
the oxidising and reducing effects of ions generated by the ultra-fineparticle ceramic.
Ion Deodorisation Filter
Organic coating fin used
heat exchanger
Using different filters at both sides
Apple-catechin
Filter
Air Filter
Apple-catechin Filter
The Apple-catechin filter uses static electricity to clean fine particles
and dust in the air.
Flexible Installation
18 type
24 type
Max. Piping
Length
25 m
30 m
Max. Height
20 m
20 m
Low ambient
operation
Cooling 46°C
Heating 24°C
-15°C
at Heating
-10°C
040
-15°C
Model: ASYG18LFCA / ASYG24LFCC
For ASYG18LFCA,
ASYG24LFCC
Wireless R.C.
Specifications
Model No.
Indoor unit
ASYG18LFCA
ASYG24LFCC
Outdoor unit
AOYG18LFC
AOYG24LFCC
Power Source
Single-phase, ~230V, 50Hz
Cooling
Heating
Nominal Capacity
UK Total/Sensible Cooling
Power Consumption
EER
COP
Pdesign
SEER
SCOP
Cooling/Heating
Cooling
Heating
Cooling/Heating(-10°C)
Cooling
Heating (Average)
Cooling
Heating (Average)
Cooling
Heating
Class
Annual Energy
Consumption
5.2 (0.9-6.0)
6.3 (0.9-9.1)
5.04/3.25
1.52/1.71
3.42
3.68
5.20/5.90
6.94
3.87
A++
A
262
2130
2.60
43/37/33/26
42/37/33/25
50/51
58/58
65/900/2150
320×998×238
14
620×790×298
41
Wireless
kW
kW
W/W
kW
W/W
kWh/a
Moisture Removal
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
dB(A)
Indoor(Cooling/Heating)
High
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
Airflow Rate
mm
Indoor
Net Dimensions
kg
HxWxD
mm
Weight
Outdoor
kg
Remote Controller Type
Interconnecting Cable (Suggested cable size 1.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling/Heating
Amp
Power Supply To
Connection Pipe Diameter (Gas / Liquid)
Inch
Max Pipe Length (Factory Gas Charge Pipe Length)
m
Max Height Difference
Type
Charge
g
Refrigerant
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
System List Price
£
7.1 (0.9-8.0)
8.0 (0.9-10.6)
7.13/5.15
2.20/2.21
3.23
3.61
7.10/7.10
6.11
3.80
A++
A
406
2610
2.70
49/42/37/32
48/42/37/32
55/56
64/64
68/1120/2460
320×998×238
14
620×790×298
41
Wireless
3 Core + Earth
16
9.00/12.50
20
13.50/18.50
Outdoor
1/2 & 1/4
25 (15)
20
R410A
1,200
20
-10 to 46
-15 to 24
943
5/8 & 1/4
30 (15)
20
R410A
1,650
20
-10 to 46
-15 to 24
1483
Optional parts
Wired Remote Controller:
Simple Remote Controller:
External Connect Kit:
Modbus Interface:
KNX Interface:
WiFi Interface:
UTYRVNYM
UTYRSNYM
UTYXWZXZ5
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
£104
£83
£9
£234
£265
£234
(Refer to page 102 for accessory combinations)
Dimensions
(Unit : mm)
320
998
ø32
ø16
ø12
25
520
590
721
238
1 Refrigerant pipe flare connection (Liquid)
520
2 Refrigerant pipe flare connection (Gas)
3 Drain hose connection (Drain hose)
041
SPLIT
Wall Mounted Standard Range
New Design & Large Capacity
Features
New dual suction design
Large Capacity & Powerful airflow
Achieving large capacity and powerful airflow by large heat
exchanger, long cross-flow fan, high output DC fan motor
and new airflow structure design.
Large heat exchanger
Airflow
25% Up!
Heat exchanger
volume
37% Up!
Long cross-flow fan and High
output DC fan motor
Human sensor
Human sensor catches movements of people in a room, and operates with
lower capacity when people leave the room. When people come back to
the room, it automatically returns to previous operating mode.
Human sensor
Server room function*
The following interlock operation is possible by connecting 2 indoor
units with a cable. Cooling operation can be performed even in the low
outdoor temperature and low humidity environment.
Indoor unit communication cable
• Alternative operation: Two units operate alternately
• Backup operation: When 1 unit breaks down, the other unit starts operating automatically.
• Supporting operation: Both units operate simultaneously when the loaded capacity is not enough with one unit
*2 x UTY-XWNX of optional parts are required.
High seasonal energy efficiency
30
Class
Cooling
SEER
5.69
12% increase
6.35
Low ambient operation
Heating
SCOP
Cooling
9% increase
46°C
4.15
3.80
Heating 24°C
-15°C
042
Current
NEW
Current
NEW
-15°C
-15°C
Model: ASYG30LMTA / ASYG36LMTA
Wireless R.C.
For ASYG30LMTA
ASYG36LMTA
Specifications
Model No.
Indoor unit
ASYG30LMTA
ASYG36LMTA
Outdoor unit
AOYG30LMTA
AOYG36LMTA
Power Source
Single-phase, ~230V, 50Hz
Cooling
Heating
Nominal Capacity
UK Total/Sensible Cooling
Power Consumption
EER
COP
Pdesign
SEER
SCOP
Cooling/Heating
Cooling
Heating
Cooling/Heating(-10°C)
Cooling
Heating (Average)
Cooling
Heating (Average)
Cooling
Heating
Class
Annual Energy
Consumption
8.0 (2.9-9.0)
8.8 (2.2-11.0)
7.88/5.86
2.33/2.41
3.43
3.65
8.00/6.50
6.35
4.15
A++
A+
441
2,193
2.70
50/44/38/31
49/44/39/33
52/55
65/65
67/68
1380/3600
340×1150×280
18
830×900×330
61
Wireless
kW
kW
W/W
kW
W/W
kWh/a
Moisture Removal
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
dB(A)
Indoor(Cooling/Heating)
High
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
Airflow Rate
mm
Indoor
Net Dimensions
kg
HxWxD
mm
Weight
Outdoor
kg
Remote Controller Type
Interconnecting Cable (Suggested cable size 1.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling/Heating
Amp
Power Supply To
Connection Pipe Diameter (Gas / Liquid)
Inch
Max Pipe Length (Factory Gas Charge Pipe Length)
m
Max Height Difference
Type
Charge
g
Refrigerant
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
System List Price
£
9.4 (2.9-10.0)
10.1 (2.7-11.2)
9.00/6.63
3.16/2.96
2.97
3.41
9.40/7.10
5.73
4.19
A+
A+
575
2,373
3.70
50/44/38/31
49/44/39/33
55/56
65/65
68/70
1380/3800
340×1150×280
18
830×900×330
61
Wireless
3 Core + Earth
16
14.50/14.50
20
19.00/19.00
Outdoor
5/8 & 3/8
50 (20)
30
R410A
2,100
40
-15 to 46
-15 to 24
2100
5/8 & 3/8
50 (20)
30
R410A
2,100
40
-15 to 46
-15 to 24
2240
Optional parts
Wired Remote Controller (Touch panel (two-wire)):
Wired Remote Controller (High grade (three-wire)):
Wired Remote Controller (two-wire):
Simple Remote Controller (three-wire):
External input and output PCB (with box):
External Connect Kit:
External Connect Kit:
UTYRNRYZ1 + UTYTWRX
UTYRVNYM + UTYXWNX
UTYRLRY + UTYTWRX
UTYRSNYM,+ UTYXWNX
UTYXCSXZ1 + UTZGXXB
UTYXWZX
UTYXWNX
£161 + £78
£104 + £17
£125 + £78
£83 + £17
£85 + £28
£9
£17
Modbus Interface:
KNX Interface:
WiFi Interface:
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
£234
£265
£234
(Refer to page 102 for accessory combinations)
Dimensions
(Unit : mm)
280
340
1150
043
SPLIT
NEW
Wall Mounted ECO Range
Compact & Comfort
Features
High efficient compact design
High density heat exchanger
Making the tube thin:
7 mm 5 mm
Even temperature
Volume reduction of heat
exchanger:
Improved heat
exchanger effectiveness
30%
From wake up to go to work
ON-OFF Programmable timer
PM11:00
set
You can set an integrated ON-OFF or OFF-ON timer suitable for
your life style. (Setting time: 0.5, 1, 1.5, 2, 2.5, -----9.5, 10, 11, 12
hours)
From sleep to wake up
OFF
2hours 12
12
OFF
10hours 9
PM9:00 9
set
3
6
6
ON
7hours
ON
9hours
ON-OFF timer
OFF-ON timer
Temperature
Powerful operation
20 minutes continuous operation by maximum airflow and maximum compressor
speed is possible. Rapid cooling and heating makes the room comfortable quickly.
3
Setting temp.
Normal mode
Powerful operation mode
Time
Economy operation
Low ambient operation
Setting temp. is shifted by 1°C automatically.
Temp.
Cooling
Economy operation
Heating 24°C
Shift setting temp
Set temperature
-15°C
at Heating
Normal operation
-10°C
(In case of cooling operation)
044
43°C
Time
-15°C
Model: ASYG09LLCE / ASYG12LLCE
Wireless R.C.
For ASYG09LLCE
ASYG12LLCE
Specifications
Model No.
Indoor unit
ASYG09LLCE
ASYG12LLCE
Outdoor unit
AOYG09LLCE
AOYG12LLCE
Power Source
Single-phase,~230V,50Hz
Cooling
Heating
Nominal Capacity
UK Total/Sensible Cooling
Power Consumption
EER
COP
Pdesign
SEER
SCOP
Cooling/Heating
Cooling
Heating
Cooling/Heating(-10°C)
Cooling
Heating (Average)
Class
Annual Energy
Consumption
Cooling
Heating (Average)
Cooling
Heating
Moisture Removal
kW
kW
W/W
kW
W/W
kWh/a
I/h
Indoor (Cooling)
H/M/L/Q
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
dB(A)
Indoor(Cooling/Heating)
High
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
Airflow Rate
mm
Indoor
Net Dimensions
kg
HxWxD
mm
Weight
Outdoor
kg
Remote Controller Type
Interconnecting Cable (Suggested cable size 1.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling/Heating
Amp
Power Supply To
Connection Pipe Diameter (Gas / Liquid)
Inch
Max Pipe Length (Factory Gas Charge Pipe Length)
m
Max Height Difference
Type
Charge
g
Refrigerant
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
System List Price
£
Sound Pressure Level
2.5(0.9-3.0)
3.0(0.9-3.8)
2.42 / 1.59
0.730-0.740
3.42
4.05
2.50/2.30
6.90
4.00
A++
A+
127
3.4(0.9-3.8)
4.0(0.9-5.0)
3.29 / 2.14
1.080/1.130
3.15
3.54
3.40/3.20
6.60
3.80
A++
A
180
805
1.30
1,179
1.80
43/38/33/22
43/38/33/22
47/48
59/60
61/61
720/1,670
262×820×206
7.0
535×663×293
24
Wireless
43/38/33/22
43/38/33/22
50/51
59/60
65/65
720/1,830
262×820×206
7.0
535×663×293
26
Wireless
3 Core + Earth
10
6.00/7.50
10
6.50/9.00
Outdoor
3/8 & 1/4
20(15)
15
R410A
650
20
-10 to 43
-15 to 24
555
3/8 & 1/4
20(15)
15
R410A
850
20
-10 to 43
-15 to 24
632
Optional parts
Remote Controller Holder: UTZRXLA
£8
Dimensions
(Unit : mm)
820
262
206
045
SPLIT
Floor
Compact & Comfort
Features
2-Fan & Wide airflow
Prevents cold air
from falling
Cooling
Prevents cold
draft from
window
Heating
Individual vertical airflow by 2-fan can control
the whole room comfortably.
at operation
start
Flexible & easy installation
Due to compact and whole surface suction
method model, floor, concealed, half concealed,
or wall mounted installation can be available to
match the room layout.
at operation
start
at stable
operation
Beneath
standard window
Window
at stable
operation
Standard alcove
portion
Partly
Recessed
Wall
Min.940
Min.
590
Min.
700
600
700
740
Min. 730
Max. 150
200
(unit:mm)
(unit:mm)
(unit:mm)
Max.
80
(unit:mm)
Flexible piping connection 6 possible ways of drain & piping
Drain hose and piping can be installed flexibly in the right, left, side, and down directions
Back view
1
6
2
10°C HEAT Operation
20°C
10°C
046
4
Low ambient operation
The room temperature can be set to go no lower than 10°C, thus
ensuring that the room does not get too cold when not occupied
“10°C HEAT” Button ON
3 Drain hose
5
Cooling
43°C
Heating 24°C
-15°C
at Heating
Indoor unit operation START
-10°C
-15°C
Piping
Model: AGYG09LVCA / AGYG12LVCA / AGYG14LVCA
For AGYG09/12LVCA
For AGYG14LVCA
Wireless R.C.
Specifications
Model No.
Indoor unit
AGYG09LVCA
AGYG12LVCA
AGYG14LVCA
Outdoor unit
AOYG09LVCA
AOYG12LVCA
AOYG14LVLA
Power Source
Nominal Capacity
UK Total/Sensible Cooling
Power Consumption
EER
COP
Pdesign
SEER
SCOP
Class
Annual Energy
Consumption
Cooling
Heating
kW
Cooling/Heating
Cooling
Heating
Cooling/Heating(-10°C)
Cooling
Heating (Average)
Cooling
Heating (Average)
Cooling
Heating
Moisture Removal
kW
W/W
kW
W/W
kWh/a
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
dB(A)
Indoor(Cooling/Heating)
High
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
Airflow Rate
mm
Indoor
Net Dimensions
kg
HxWxD
mm
Weight
Outdoor
kg
Remote Controller Type
Interconnecting Cable (Suggested cable size 1.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling/Heating
Amp
Starting Current
Amp
Power Supply To
Connection Pipe Diameter (Gas / Liquid)
Inch
Max Pipe Length (Factory Gas Charge Pipe Length)
m
Max Height Difference
Type
Charge
g
Refrigerant
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
System List Price
£
2.60 (0.90-3.50)
3.50 (0.90-5.50)
2.49/2.24
0.53/0.79
4.91
4.43
2.60/2.90
7.00
4.20
A++
A+
130
967
1.30
40/35/29/22
40/35/29/22
47/48
55/56
64/65
570/1680
600×740×200
14
540×790×290
36
Wireless
10
7.00/10.00
3.80
3/8 & 1/4
20 (15)
15
R410A
1,050
20
-10 to 43
-15 to 24
1148
Single-phase, ~230V, 50Hz
3.50 (0.90-4.00)
4.50 (0.90-6.60)
3.36/2.59
0.94/1.19
3.72
3.78
3.50/3.80
6.50
4.00
A++
A+
188
1330
1.80
40/35/29/22
40/35/29/22
48/49
55/56
64/65
570/1680
600×740×200
14
540×790×290
36
Wireless
3 Core + Earth
10
7.00/10.00
5.50
Outdoor
3/8 & 1/4
20 (15)
15
R410A
1,050
20
-10 to 43
-15 to 24
1287
4.20 (0.90-5.00)
5.20 (0.90-8.00)
4.03/2.92
1.14/1.44
3.68
3.61
4.20/4.70
6.40
4.00
A++
A+
230
1645
2.10
44/38/31/22
43/37/29/22
50/50
58/58
65/66
650/1910
600×740×200
14
578×790×300
40
Wireless
16
9.00/13.50
6.40
1/2 & 1/4
20 (15)
15
R410A
1,150
20
-10 to 43
-15 to 24
1480
Optional parts
Wired Remote Controller:
Simple Remote Controller:
External Connect Kit:
Modbus Interface:
KNX Interface:
WiFi Interface:
UTYRVNYM
UTYRSNYM
UTYXWZX
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
£104
£83
£9
£234
£265
£234
(Refer to page 102 for accessory combinations)
Dimensions
(Unit : mm)
600
200
740
Front view
Side view
047
SPLIT
Compact Cassette
4-way Flow Compact & Comfort
Features
2-stage turbo fan
High efficiency design by 2 stage fan
Air
velocity
Fast
Previous turbo fan
2-stage turbo fan
In the case of a conventional
fan, the air outlet range was
narrow as the airflow moved
to the motor side which
meant the velocity of air
passing through the heat
exchanger was uneven.
An evenly spread air distribution across
the heat exchanger is possible due to
the new 2 stage turbo fan which
produces two separate airflow streams.
1-stage
+
Slow
2-stage
2 stage
Heat exchange
efficiency:
20
%UP
Designed by CFD-analysis (fluid) simulations
Quiet Air flow
Quiet
Laminar wing
Optimised wing form (laminar wing type) and wing number (7
blades each)
Airflow runs through smoothly along
the laminar wing
No airflow separation
Quiet
Spin direction
Improvement of the airflow distribution
Front part
Adoption of laminar wing
Airflow direction
Ceiling
New louvre: The louvre design distributes air leaving a
space between the chassis and the ceiling allowing far
and wide airflow distribution.
Rear part
Bottom view
Much less temperature irregularity
by spreading airflow widely
Round louvre
Low ambient operation
Cooling
46°C
Heating
-15°C
24°C
at Heating
-10°C
048
-15°C
Model : AUYG12LVLB / AUYG14LVLB / AUYG18LVLB / AUYG24LVLA
For AUYG12/14/18LVLB
For AUYG24LVLA
Wireless R.C.
Specifications
Model No.
Indoor unit
AUYG12LVLB
AUYG14LVLB
AUYG18LVLB
AUYG24LVLA
Outdoor unit
AOYG12LALL
AOYG14LALL
AOYG18LALL
AOYG24LALA
Power Source
Nominal Capacity
UK Total / Sensible Cooling
Input Power
EER
COP
Pdesign
SEER
SCOP
Class
Annual Energy
Consumption
Cooling
Heating
Cooling / Heating
Cooling
Heating
Cooling / Heating(-10°C)
Cooling
Heating (Average)
Cooling
Heating (Average)
Cooling
Heating
Single-phase, ~230V, 50Hz
4.3 (0.9-5.4)
5.2 (0.9-5.9)
5.0 (0.9-6.5)
6.0 (0.9-7.5)
3.96 / 2.70
4.79 / 3.09
1.33 / 1.34
1.62 / 1.66
3.21
3.21
3.71
3.61
4.3 / 4.5
5.2 / 5.2
6.40
6.20
4.40
4.20
A++
A++
A+
A+
235
293
1432
1731
1.5
2.2
38/34/30/27
38/34/30/26
43/38/34/30
43/38/34/30
49 / 49
50 / 50
50 / 55
50 / 55
62 / 64
62 / 65
680 / 1910
680 / 2000
245×570×570
245×570×570
15
15
578×790×300
578×790×300
40
40
Wireless
Wireless
3 Core + Earth
16
16
9.0 / 12.5
9.0 / 12.5
Outdoor
1/2 & 1/4
1/2 & 1/4
25 (15)
25 (15)
15
15
R410A
R410A
1,250
1,250
20
20
-10 to 46
-10 to 46
-15 to 24
-15 to 24
UTG-UFYD-W
UTG-UFYD-W
49×700×700
49×700×700
2.6
2.6
1467
1615
3.5 (0.9-4.4)
4.1 (0.9-5.7)
3.46 / 2.37
1.05 / 1.11
3.33
3.69
3.5 / 4.2
6.20
4.10
A++
A+
198
1431
1.2
37/34/30/27
37/34/31/29
47 / 48
49 / 49
61 / 63
600 / 1780
245×570×570
15
578×790×300
40
Wireless
kW
kW
kW
W/W
kW
W/W
kWh/a
Moisture Removal
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
dB(A)
Indoor(Cooling / Heating) High
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
mm
Indoor
Net Dimensions
kg
HxWxD
mm
Weight
Outdoor
kg
Remote Controller Type (Supplied with unit)
Interconnecting Cable(Suggested cable size 1.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling / Heating
Amp
Power Supply To
Connection Pipe Diameter (Gas & Liquid)
Inch
Max Pipe Length (Factory Gas Charge Pipe Length)
m
Max Height Difference
Type
Refrigerant
Charge
g
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
Model name
Cassette Grille
Dimensions (H × W × D)
mm
Weight
kg
System List Price
£
16
7.5 / 10.0
3/8 & 1/4
25 (15)
15
R410A
1,150
20
-10 to 46
-15 to 24
UTG-UFYD-W
49×700×700
2.6
1191
6.8 (0.9-8.0)
8.0 (0.9-9.1)
5.94 / 4.42
2.21 / 2.26
3.08
3.54
6.8 / 6.0
5.60
3.90
A+
A
425
2151
2.7
49/44/36/30
49/45/40/33
52 / 53
59 / 61
67 / 70
930 / 2470
245×570×5700
16
578×790×315
44
Wireless
16
12.0 / 13.5
5/8 & 1/4
30 (15)
20
R410A
1,700
20
-10 to 46
-15 to 24
UTG-UFYD-W
49×700×700
2.6
1988
Optional parts
Wired Remote Controller:
Simple Remote Controller:
External Connect Kit:
Fresh Air Intake Kit:
UTYRVNYM
UTYRSNYM
UTYXWZX
UTZVXAA
Modbus Interface:
KNX Interface:
WiFi Interface:
£104
£83
£9
£291
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
£234
£265
£234
700 mm
(Refer to page 102 for accessory combinations)
Dimensions
(Unit : mm)
285
Ƒ 580 to 660
Ceiling openings
Drain hose
183
146
40
30
262
30
Control Box Gas pipe
Liquid pipe
123
19
Ceiling
114
114
215
285
370
Ƒ 570 : Indoor unit
530
700
IR receiver
540
Hanging bolt position
530
Hanging bolt position
700
049
SPLIT
Cassette
Circular Flow Comfort for large room
(30/36/
45/54)
Features
Unique Circular Flow design
New Cassette type realises Circular Flow
to blow large airflow in 360º direction by
mounting high performance DC fan motor,
new turbo fan and unique seamless
airflow louvre design.
ø7mm high density
Heat exchanger
New DC fan motor
High efficient turbo fan
Seamless airflow louvre
Individual louvre control
Each louvre can be set individually by Touch Panel Wired Remote
Controller to enjoy the comfort of different directional airflows according
to various room layouts.
*Touch Panel Wired RC (UTY-RNRYZ2)only
Comfortable air conditioning by
preventing direct blowing of cold air
and by providing swinging air flow
simultaneously.
Human sensor increases more energy saving
Efficient air conditioning based on the
room layout
2 modes can be selected.
Energy saving operation starts automatically by detecting the motion
of a person. 2 modes of save operation mode and stop mode can be
selected.
Auto saving
Power is saved while
people are away.
Auto OFF
Operation stops after
people go out.
*Touch Panel Wired RC (UTY-RNRYZ2) only
Human sensor (Option)
Condensate lift pump height
Ceiling panel
850 mm
050
Model: AUXG18LRLB / AUXG24LRLB
AUXG30LRLB / AUXG36LRLB / AUXG45LRLB / AUXG54LRLB
Touch Panel Wired R.C.
AUXG18/24LRLB
6/45/54LRLB
AUXG30/36/45/54LRLB
For AUXG18/24LRLB
For AUXG30/36LRLB
For AUXG45/54LRLB
Specifications
Model No.
Indoor unit
AUXG18LRLB
AUXG24LRLB
AUXG30LRLB
AUXG36LRLB
AUXG45LRLB
AUXG54LRLB
Outdoor unit
AOYG18LBCA
AOYG24LBCA
AOYG30LBTA
AOYG36LBTA
AOYG45LBTA
AOYG54LBTA
5.2 (0.9-6.5)
6.0 (0.9-8.0)
6.0 / 4.54
1.42 / 1.50
3.66
4.00
5.2 / 4.3
7.05
4.40
A++
A+
258
1367
2.2
33/32/31/28
33/32/31/28
51/50
47/47
64/62
1050/1900
246×840×840
24
620×790×290
41
Wired
6.8 (0.9-8.0)
7.8 (0.9-9.1)
6.99 / 5.2
2.16 / 2.18
3.15
3.58
6.8 / 6.0
6.60
4.20
A++
A+
361
1999
2.7
35/33/32/29
35/33/32/29
55/56
49/49
68/68
1150/2460
246×840×840
24
620×790×290
41
Wired
12.5 (4.0-14.0)
14.0 (4.2-16.2)
13.06 / 9.67
3.85 / 3.73
3.25
3.75
4.5
46/42/39/35
46/42/39/35
55/55
60/60
68/68
2000/6750
288×840×840
29
1290×900×330
86
Wired
13.3 (4.5-14.5)
15.8 (4.7-16.5)
13.39 / 9.82
4.38 / 4.58
3.04
3.45
5.0
47/43/40/36
47/43/40/36
55/57
61/61
69/71
2100/6750
288×840×840
29
1290×900×330
86
Wired
25
20.5 / 20.5
25
21.5 / 21.5
5/8 & 3/8
50 (20)
30
R410A
3,350
40
-15 to 46
-15 to 24
UTG-UKYA-W
53×950×950
6.0
3154
5/8 & 3/8
50 (20)
30
R410A
3,350
40
-15 to 46
-15 to 24
UTG-UKYA-W
53×950×950
6.0
3662
Power Source
Cooling
Heating
Nominal Capacity
kW
UK Total / Sensible Cooling
kW
Input Power
Cooling / Heating
kW
EER
Cooling
W/W
COP
Heating
Pdesign
Cooling / Heating (@ -10°C)
kW
SEER
Cooling
W/W
SCOP
Heating (Average)
Cooling
Class
Heating (Average)
Cooling
Annual Energy
kWh/a
Consumption
Heating
Moisture Removal
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure
Indoor (Heating)
H/M/L/Q
Level
Outdoor(Cooling/Heating) High
dB(A)
Indoor (Cooling/Heating) High
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
mm
Indoor
Net Dimensions
kg
HxWxD
mm
Weight
Outdoor
kg
Remote Controller Type (Supplied With Grille)
Interconnecting Cable (Suggested cable size 1.5 mm)
Amp
Suggested MCB Size
Max. Operating Current
Cooling / Heating
Amp
Power Supply To
Connection Pipe Diameter (Gas & Liquid)
Inch
Max Pipe Length (Factory Gas Charge Pipe Length)
m
Refrigerant
Operation Range
Cassette Grille
(to be ordered
separately)
System List Price
Type
Charge
Additional Charge
Cooling
Heating
Model name
Dimensions (H × W × D)
Weight
g
g/m
°CDB
mm
kg
£
16
10.0 / 13.5
20
13.5 / 18.5
1/2 & 1/4
30 (15)
20
R410A
1,800
20
-15 to 46
-15 to 24
UTG-UKYA-W
53×950×950
6.0
2003
5/8 & 1/4
30 (15)
20
R410A
1,800
20
-15 to 46
-15 to 24
UTG-UKYA-W
53×950×950
6.0
2127
Single-phase, ~230V, 50Hz
8.5 (2.8-10.0)
9.5 (2.8-11.2)
10.0 (2.7-11.2)
10.8 (2.7-12.7)
10.15 / 7.32
11.79 / 8.49
2.56 / 2.77
2.96 / 2.91
3.32
3.21
3.61
3.71
8.5 / 8.0
9.5 / 8.7
6.70
6.40
4.30
4.30
A++
A++
A+
A+
444
519
2604
2833
2.5
3.3
40/38/36/33
44/41/38/34
40/38/36/33
44/41/38/34
53/55
54/55
54/54
58/58
67/69
68/70
1600/3600
1900/3800
288×840×840
288×840×840
26
26
830×900×330
830×900×330
61
61
Wired
Wired
3 core + Earth
20
25
17.0 / 17.0
20.0 / 20.0
Outdoor Unit
5/8 & 3/8
5/8 & 3/8
50 (20)
50 (20)
30
30
R410A
R410A
2,100
2,100
40
40
-15 to 46
-15 to 46
-15 to 24
-15 to 24
UTG-UKYA-W
UTG-UKYA-W
53×950×950
53×950×950
6.0
6.0
2426
2859
Optional parts
Simple Remote Controller:
IR Receiver Kit:
Human Sensor Kit:
Fresh Air Intake Kit:
External Input & Output PCB (with box):
External Connect Kit:
UTYRSNYM
UTYLBTYC
UTYSHZXC
UTZVXRA
UTYXCSX + UTZGXRA
UTYXWZXZG, UTYXWZXZ3
£83
£98
£61
£364
£85 + £53
£8, £9
Modbus Interface:
KNX Interface:
WiFi Interface:
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
£234
£265
£234
(Refer to page 102 for accessory combinations)
Dimensions
(Unit : mm)
950
Human sensor (Option)
(Control) box
Wire hole
860 to 910
Ceiling openings
Drain hose
Liquid pipe
38
Ceiling
Gas pipe
298 (256)
950
840: Indoor unit
IR receiver (Option)
( ): AUXG18/24LRLB
051
SPLIT
Cassette
4-way Flow Comfort for large room
Single
phase
(45/54)
Features
High efficiency turbo fan with 3-dimensional blade
Previous turbo fan: Air passing through the heat exchanger was
uneven and the air would only flow close to the ceiling.
New turbo fan: High efficiency airflow distribution has been achieved
by the introduction of a 3 dimensional blade which increases the air
passing over the heat exchanger.
500 mm
450 mm
Separation
phenomenon of
airflow
causes noise
Wind
velocity
Heat exchanger
< Motor side >
Uneven airflow
Fast
No airflow
separation
Quiet
Heat exchanger
< Motor side >
Conventional blade
3-dimensional blade
Slow
: Spin direction
Improvement of the airflow distribution
Front part
: Airflow direction
: Turbulent flow noise
Ceiling
New louvre: The louvre design distributes air leaving a
space between the chassis and the ceiling allowing far
and wide airflow distribution.
Rear part
Bottom view
Much less temperature irregularity
by spreading airflow widely
Round louvre
Adjustment of hanger position is
possible after installation
Detachable
Grille corner
Hanging bracket can be checked directly by removing the corner
cover. Hanging position can be arranged easily.
Adjustment can be done
just taking off the corner
part
Low ambient operation
Cooling
46°C
Heating
-15°C
-15°C
052
24°C
-15°C
Model : AUYG30LRLE / AUYG36LRLE / AUYG45LRLA / AUYG54LRLA /
AUYG36LRLA [3phase] / AUYG45LRLA [3phase] / AUYG54LRLA [3phase]
Wired R.C.
For AUYG30/36LRLE
For AUYG36/45/54LRLA
Specifications
Model No.
Indoor unit
AUYG30LRLE
AUYG36LRLE
AUYG45LRLA
AUYG54LRLA
AUYG36LRLA
AUYG45LRLA
AUYG54LRLA
Outdoor unit
AOYG30LETL
AOYG36LETL
AOYG45LETL
AOYG54LETL
AOYG36LATT
AOYG45LATT
AOYG54LATT
Power Source
Cooling
Heating
Nominal Capacity
kW
UK Total / Sensible Cooling
kW
Input Power
Cooling / Heating
kW
EER
Cooling
W/W
COP
Heating
Pdesign
Cooling / Heating (-10°C)
kW
SEER
Cooling
W/W
SCOP
Heating (Average)
Cooling
Class
Heating (Average)
Cooling
Annual Energy
kWh/a
Consumption
Heating
Moisture Removal
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
dB(A)
Indoor(Cooling/Heating)
High
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
mm
Indoor (ex grille)
Net Dimensions
kg
HxWxD
mm
Weight
Outdoor
kg
Remote Controller Type (Supplied with unit)
Interconnecting Cable (Suggested cable size 1.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling / Heating
Amp
Power Supply To
Connection Pipe Diameter (Gas & Liquid)
Inch
Max Pipe Length (Factory Gas Charge Length)
m
Max Height Difference
Type
Refrigerant
Charge
g
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
Model name
Cassette Grille
Dimensions (H × W × D)
mm
Weight
kg
System List Price
£
8.5 (2.8-10.0)
10.0 (2.7-11.2)
8.63 / 6.22
2.65 / 2.77
3.21
3.61
8.5 / 8.0
6.50
4.30
A++
A+
458
2604
2.5
40/38/36/32
40/38/36/32
53/55
54/54
68/69
1600/3600
288x840x840
26
830×900×330
61
Wired
20
17.0 / 17.0
5/8 & 3/8
50 (20)
30
R410A
2,100
40
-15 to 46
-15 to 24
UTG-UGYA-W
50×950×950
5.5
2265
Single-phase, ~230V, 50Hz
10.0 (2.8-11.2) 12.5 (4.0-14.0)
11.2 (2.7-12.7) 14.0 (4.2-16.2)
10.53 / 7.58
11.66 / 8.63
3.12 / 3.02
3.88 / 3.77
3.21
3.22
3.71
3.71
10.0 / 8.7
6.30
4.20
A++
A+
555
2897
3.5
4.5
43/38/36/32
46/42/40/36
46/42/40/36
43/38/36/32
54/55
55/55
57/57
69/70
1800/3800
1900/6750
288x840x840 288x840x840
26
26
830×900×330 1290×900×330
61
86
Wired
Wired
3 Core + Earth
25
25
18.5 / 20.0
20.5 / 20.5
Outdoor
5/8 & 3/8
5/8 & 3/8
50 (20)
50 (20)
30
30
R410A
R410A
2,100
3,350
40
40
-15 to 46
-15 to 46
-15 to 24
-15 to 24
UTG-UGYA-W
UTG-UGYA-W
50×950×950
50×950×950
5.5
5.5
2608
2828
13.3 (4.5-14.5)
16.0 (4.7-16.5)
12.28 / 9.01
4.42 / 4.69
3.01
3.41
5.0
47/43/41/37
47/43/41/37
55/57
2000/6750
288x840x840
26
1290×900×330
86
Wired
25
21.5 / 21.5
5/8 & 3/8
50 (20)
30
R410A
3,350
40
-15 to 46
-15 to 24
UTG-UGYA-W
50×950×950
5.5
3271
3-phase, ~400V, 50Hz
10.0 (4.7-11.4) 12.5 (5.0-14.0) 14.0 (5.4-16.0)
11.2 (5.0-14.0) 14.0 (5.4-16.2) 16.0 (5.8-18.0)
9.27 / 6.42
11.63 / 7.64
12.87 / 8.51
2.44 / 2.56
3.54 / 3.58
4.36 / 4.43
4.10
3.53
3.21
4.38
3.91
3.61
10.0 / 10.0
6.50
4.30
A++
A+
573
3253
3.0
4.5
5.0
44/39/36/33
46/42/40/36
47/43/41/37
44/39/36/33
46/42/40/36
47/43/41/37
51/53
54/54
55/56
58/58
67/69
1800/6200
1900/6900
2000/6900
288x840x840 288x840x840 288x840x840
26
26
26
1290×900×330 1290×900×330 1290×900×330
104
104
104
Wired
Wired
Wired
3 Core + Earth
16
16
16
7.9 / 7.9
8.9 / 8.9
9.9 / 9.9
Outdoor
5/8 & 3/8
5/8 & 3/8
5/8 & 3/8
75 (30)
75 (30)
75 (30)
30
30
30
R410A
R410A
R410A
3,450
3,450
3,450
50
50
50
-15 to 46
-15 to 46
-15 to 46
-15 to 24
-15 to 24
-15 to 24
UTG-UGYA-W
UTG-UGYA-W
UTG-UGYA-W
50×950×950
50×950×950
50×950×950
5.5
5.5
5.5
2621
2974
3449
Optional parts
Wired Remote Controller:
Simple Remote Controller:
IR Receiver Kit:
External Connect Kit:
Fresh Air Intake Kit:
UTYRVNYM
UTYRSNYM
UTYLRHYA2
UTYXWZX
UTZVXGA
Modbus Interface:
KNX Interface:
WiFi Interface:
£104
£83
£76
£9
£364
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
£234
£265
£234
(Refer to page 102 for accessory combinations)
Dimensions
(Unit : mm)
796
Hanging bolt position
(Control) Box
420
699
Hanging bolt position
Ƒ 860 to 910
Ceiling opening
950
Ƒ 840 : Indoor unit
607
950
358
358
278
60
Liquid pipe Gas pipe
Wire hole
44
140
200
10
142
142
850 mm
Drain hose
40
Ceiling
Ceiling panel
298(256)
IR receiver
(Option)
053
SPLIT
NEW
Bulkhead Duct
Built-in Drain Pump
Features
198mm
• Installation space can be reduced down to a minimum depth of
450 mm and height of 198 mm and providing a compact design
• Minimum size: Depth 450 mm, Height 198 mm Volume 30%
down compared with current model
• Lightweight: 16 kg 10% down
0
45
Optimum airflow path and low
noise operation
Low noise is realised drastically by stabilised
airflow design
223mm
Large living space available
m
m
60
0m
m
V-shape heat exchanger
Air Stabiliser
High efficient DC fan motor
Lower power consumption
Easy design and maintenance for drain
By using the DC fan motor, it is possible to change the static pressure range
from 0 to 50 Pa*.
The change of static pressure range is possible by remote controller.
*: 0 to 30 Pa. (12)
Built-in drain pump as standard:
Maintenance is easy
Parts can be replaced from
the side of the body where
maintenance is easier
Auto Louvre Grille Kit (Option)
• Thin design provides a comfortable living environment over a wide area.
• Automatic louvre grille provides comfortable air conditioning all the way
down to the floor and matches the interior design well. (Optional)
054
Easy
Washable filter
Model : ARYG12LSLAP / ARYG14LSLAP / ARYG18LSLAP
(Horizontal only installation)
Wired R.C.
ARYG12/14LSLAP
ARYG18LSLAP
Specifications
Model No.
Indoor unit
ARYG12LSLAP
ARYG14LSLAP
ARYG18LSLAP
Outdoor unit
AOYG12LALL
AOYG14LALL
AOYG18LALL
Power Source
Cooling
Heating
Capacity
UK Total/Sensible Cooling
Input Power
EER
COP
Pdesign
SEER
SCOP
kW
kW
kW
Cooling/Heating
Cooling
Heating
Cooling/Heating(-10°C)
Cooling
Heating
Cooling
Heating
Cooling
Heating
(QHUJ\(IÀFLHQF\
Class
Annual Energy
Consumption
W/W
kW
W/W
kWh/a
Moisture Removal
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
Indoor(Cooling/Heating)
High
Sound Power Level
Outdoor(Cooling/Heating) High
$LUÁRZ5DWH
Indoor / Outdoor
High
Static pressure range (Standard)
Indoor
Net Dimensions
HxWxD
Weight
Outdoor
Remote Controller Type (Supplied With Unit)
Interconnecting Cable (Suggested cable size 1.5mm)
Suggested MCB Size
Max. Operating Current
Cooling/Heating
Power Supply To
Connection Pipe Diameter (Gas & Liquid)
Max Pipe Length (Factory Gas Charge Length)
Max Height Difference
Type
Refrigerant
Charge
Additional Charge
Cooling
Operation Range
Heating
System List Price
dB(A)
m3/h
Pa
mm
kg
mm
kg
Single-phase, ~230V, 50Hz
4.30 (0.90-5.40)
5.00 (0.90-6.50)
4.11 / 3.15
1.34/1.49
3.21
3.35
4.3/4.5
5.60
3.80
A+
A
269
1656
1.4
35/30/27/23
35/30/27/23
49/49
60/62
62/64
800/1910
0 - 50 (15)
198×700×450
15.5
578×790×300
40
Wired
3 Core + Earth
16
9.0/12.5
Outdoor
1/4 & 1/2
25 (15)
15
R410A
1250
TBC
-10 to 46
-15 to 24
1386
3.50 (0.90-4.40)
4.10 (0.90-5.70)
3.36 / 2.56
1.03/1.15
3.40
3.56
3.5/4.2
5.70
3.90
A+
A
215
1505
1.2
31/27/25/23
31/27/25/23
47/48
55/57
61/63
650/1780
0 - 30 (10)
198×700×450
15.5
578×790×300
40
Wired
Amp
Amp
16
7.5/10.0
Inch
1/4 & 3/8
25 (15)
15
R410A
1150
TBC
-10 to 46
-15 to 24
1281
m
g
g/m
°CDB
£
5.20 (0.90-5.90)
6.00 (0.90-7.50)
4.98 / 3.79
1.62/1.77
3.21
3.38
5.2/5.2
5.80
3.80
A+
A
314
1914
1.8
33/29/26/23
33/29/26/23
50/50
58/59
62/65
940/2000
0 - 50 (15)
198×900×450
18.5
578×790×300
40
Wired
16
9.0/12.5
1/4 & 1/2
25 (15)
15
R410A
1250
TBC
-10 to 46
-15 to 24
1581
Optional parts
Wired Remote Controller:
Simple Remote Controller:
Simple Remote Controller:
IR Receiver Kit:
Remote Sensor Unit:
External connect Kit:
UTYRNRYZ2
UTYRSNYM
UTYRSRY
UTYLBTYM
UTYXSZX
UTYXWZXZG
£161
£83
£120
£266
£56
£8
Auto Louvre Grille Kit: UTDGXSAW (ARYG12/14LSLAP) £135
UTDGXSBW (ARYG18LSLAP)
£151
(Refer to page 102 for accessory combinations)
Dimensions
(Unit : mm)
A
(Bolt pitch)
R
Air
198
Liquid: D
Gas: E
Drain hose is a standard accessory
View R (Rear view)
Drain port
(VP25: ID25mm, OD32mm)
198
151
78
Drain hose (Accessory)
(VP25: ID25mm, OD32mm)
198
C
B
151
315
(Bolt pitch)
30
469
Max.
850 mm
Control box
Drain port
(VP25: ID25mm, OD32mm)
Control box
Drain port
(VP25: ID25mm, OD32mm)
A
B
C
D
E
ARYG12/14LSLAP
ARYG18LSLAP
752
700
650
6.35
12,7
952
900
850
9.52
15.88
055
SPLIT
Slim Duct
Slim & Comfort
Features
Slim design
Drain port
The slim design allows installations where ceilings are narrow.
Drain hose as standard accessory
Height
198 mm
Drain pump
Flexible installation
Ceiling concealed
Drain pump
built-in
Floor concealed
2-type installation methods of ceiling concealed and floor concealed
can be selected. Can also be installed in a Bulkhead.
Selectable with a wide range of static pressure
By using the DC fan motor, it is possible to change the static pressure range from
0 to 90 Pa.
The change of static pressure range is possible by using the remote controller.
Static pressure range
0 to 90 Pa
Auto Louvre Grille Kit (Option)
Simple flat Auto Louvre will provide
comfortable airflow and harmonise
with the interior.
Auto Louvre Grille
Cooling 46°C
Duct type
Heating
-15°C
4 steps
selectable
and auto swing
at Heating
-10°C
Wireless Remote
Controller
056
24°C
Wired Remote
Controller
-15°C
Model : ARYG12LLTB / ARYG14LLTB / ARYG18LLTB
Wired R.C.
ARYG12/14LLTB
ARYG18LLTB
Specifications
Model No.
Indoor unit
ARYG12LLTB
ARYG14LLTB
ARYG18LLTB
Outdoor unit
AOYG12LALL
AOYG14LALL
AOYG18LALL
Power Source
Cooling
Heating
Capacity
Single-phase, ~230V, 50Hz
4.3 (0.9-5.4)
5.0 (0.9-6.5)
3.97 / 2.90
1.33 / 1.34
3.21
3.71
4.3 / 4.5
5.80
3.90
A+
A
259
1614
1.5
32/30/28/26
32/30/28/25
49 / 49
60 / 60
62 / 64
800 / 1910
0 to 90 (25)
198×700×620
19
578×790×300
40
Wired
3 Core + Earth
16
9.0 / 12.5
Outdoor
1/2 &1/4
25 (15)
15
R410A
1,250
20
-10 to 46
-15 to 24
1363
3.5 (0.9-4.4)
4.1 (0.9-5.7)
3.48 / 2.47
1.05 / 1.11
3.33
3.69
3.5 / 4.2
5.90
4.00
A+
A+
207
1467
1.3
29/28/26/25
29/28/26/24
47 / 48
58 / 58
61 / 63
650 / 1780
0 to 90 (25)
198×700×620
19
578×790×300
40
Wired
kW
UK Total / Sensible Cooling
kW
Input Power
Cooling / Heating
kW
EER
Cooling
W/W
COP
Heating
Pdesign
Cooling / Heating(-10°C)
kW
SEER
Cooling
W/W
SCOP
Heating
Cooling
Class
Heating
Cooling
Annual Energy
kWh/a
Consumption
Heating
Moisture Removal
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
dB(A)
Indoor(Cooling/Heating)
High
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
Static pressure range (Standard)
Pa
mm
Indoor
Net Dimensions
kg
HxWxD
mm
Weight
Outdoor
kg
Remote Controller Type (Supplied With Unit)
Interconnecting Cable (Suggested cable size 1.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling / Heating
Amp
Power Supply To
Inch
Connection Pipe Diameter (Gas & Liquid)
Max Pipe Length (Factory Gas Charge Length)
m
Max Height Difference
Type
Charge
g
Refrigerant
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
System List Price
£
16
7.5 / 10.0
3/8 & 1/4
25 (15)
15
R410A
1,150
20
-10 to 46
-15 to 24
1226
5.2 (0.9-5.9)
6.0 (0.9-7.5)
4.80 / 3.45
1.62 / 1.66
3.21
3.61
5.2 / 5.2
6.20
4.10
A++
A+
293
1774
2.0
32/30/29/27
32/30/29/27
50 / 50
58 / 58
62 / 65
940 / 2000
0 to 90 (25)
198×900×620
23
578×790×300
40
Wired
16
9.0 / 12.5
1/2 & 1/4
25 (15)
15
R410A
1,250
20
-10 to 46
-15 to 24
1558
Optional parts
Wired Remote Controller:
Simple Remote Controller:
IR Receiver Kit:
Remote Sensor Unit:
External Connect Kit:
UTYRVNYM
UTYRSNYM
UTYLRHYM
UTYXSZX
UTDECS5A
£104
£83
£262
£56
£14
Modbus Interface:
KNX Interface:
WiFi Interface:
Auto Louvre Grille Kit:
FJRCMBS1
£234
FJRCKNX1i
£265
FJRCWIFI1
£234
UTDGXSAW (ARYG12/14LLTB) £135
UTDGXSBW (ARYG18LLTB)
£151
Max.
850 mm
(Refer to page 102 for accessory combinations)
Drain hose is a standard accessory
Dimensions
377
(Bolt pitch)
G
82
E
D
C
(Bolt pitch)
B
A
43
31
163
119
89
78
55
47
48
30
198
168
78
F
(All surroundings)
51
174
30
152
71
(Unit : mm)
69
144
264
367
10
A
B
C
D
E
F
G
ARYG12 / 14LLTB
ARYG18LLTB
700
650
734
650
P100x6=600
18xØ5
574
900
850
934
850
P100x8=800
22xØ5
774
057
SPLIT
Medium Static Pressure Duct
(30/36/
45/54)
Compact & Comfort
(12/14/
18/24)
(30/36/
45/54)
Features
High Efficiency & Quiet operation
The combination of the V-shaped heat exchanger,
air stabiliser, and the high efficient DC fan motor
allows high efficiency and quiet operation.
Noise Level
V-shape heat exchanger
28dB(A)
ARYG18LHTBP
Air Stabiliser
High efficient DC fan motor
Lower power consumption
Automatic Airflow adjustment function
This unique and innovative function detects the required air flow for
each application and automatically adjusts the air volume.
Improved installation flexibility
• Capable to be installed in various applications that require static
pressure of 30 Pa to 200 Pa
• Built-in drain pump, rises drain up to 850 mm
• Unified depth throughout the range enables the selection of the
capacity regardless of the additional space.
36/45/54:1400mm
18/24/30:1000mm
12/14:700mm
30 Pa
Short duct
300
200 Pa
Long duct
with dumper
mm
700mm
Improved service and maintenance
• Drain pump is easily detachable from the side
• Easy access to electrical box
• Error code can be checked in more detail from
error history
058
Low ambient
operation
Cooling
46°C
Heating
-15°C
24°C
-15°C
-10°C (12/14 model)
-15°C (18/24/30/36/45/54 model)
Model: ARYG12LHTBP / ARYG14LHTBP / ARYG18LHTBP / ARYG24LHTBP
ARYG30LHTBP / ARYG36LHTBP / ARYG45LHTBP / ARYG54LHTBP
ARYG36/45/54LHTBP
ARYG12/14LHTBP
ARYG18/24/30LHTBP
Touch Panel Wired R.C.
For ARYG12/14LHTBP
For ARYG18/24LHTBP
For ARYG30/36LHTBP
For ARYG45/54LHTBP
Specifications
ARYG12LHTBP
Indoor unit
Model No.
Outdoor unit
ARYG14LHTBP
ARYG18LHTBP
Power Source
Cooling
Heating
3.5 (0.9-4.4)
4.1 (0.9-5.7)
UK Total / Sensible Cooling
kW
3.31 / 2.92
Input Power
Cooling/Heating
kW
0.90 / 1.00
EER
Cooling
3.89
W/W
COP
Heating
4.10
Pdesign
Cooling/Heating(-10°C)
kW
3.5/4.2
SEER
Cooling
6.20
W/W
SCOP
Heating (Average)
4.10
A++
Cooling
Class
Heating (Average)
A+
Cooling
198
Annual Energy
kWh/a
Consumption
Heating
1434
Moisture Removal
I/h
0.7
Indoor (Cooling)
H/M/L/Q
32/30/25/22
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
32/30/25/22
dB(A)
Outdoor(Cooling/Heating) High
47 / 48
Indoor(Cooling/Heating)
High
TBC
Sound Power Level
Outdoor(Cooling/Heating) High
61 / 63
3
Indoor / Outdoor
High
m /h
850 / 1780
Static pressure range (Standard)
Pa 30 to 200 (35)
mm 300×700×700
Indoor
Net Dimensions
kg
27
HxWxD
mm 578×790×300
Weight
Outdoor
kg
40
Remote Controller Type (Supplied with unit)
Wired
Interconnecting Cable (Suggested cable size 1.5mm)
Amp
Suggested MCB Size
15
Max. Operating Current
Cooling/Heating
Amp
7.5 / 10.0
Power Supply To
Connection Pipe Diameter (Gas & Liquid)
Inch
3/8 & 1/4
Max Pipe Length (Factory Gas Charge Length)
25 (15)
m
Max Height Difference
15
Type
R410A
Charge
g
1,150
Refrigerant
Additional Charge
g/m
20
Cooling
-10 to 46
Operation Range
°CDB
Heating
-15 to 24
Filter (to be ordered seperatley)
UTDLFNC
System List Price
£
1625
Capacity
ARYG24LHTBP
ARYG30LHTBP
ARYG36LHTBP
ARYG45LHTBP
ARYG54LHTBP
AOYG12LBLA AOYG14LBLA AOYG18LBCA AOYG24LBCA AOYG30LBTA AOYG36LBTA AOYG45LBTA AOYG54LBTA
kW
4.3 (0.9-5.4)
5.0 (0.9-6.5)
4.18 / 3.53
1.18 / 1.25
3.64
4.00
4.3/4.5
4.3/4.5
3.95
A+
A
247
1573
0.9
33/28/27/23
33/28/27/23
49 / 49
TBC
62 / 63
950 / 1910
30 to 200 (35)
300×700×700
27
578×790×300
40
Wired
5.2 (0.9-6.5)
6.0 (0.9-8.0)
4.57 / 3.37
1.37 / 1.48
3.80
4.05
5.2/ 4.3
7.15
4.11
A++
A+
255
1462
1.2
28/25/22/20
28/25/22/20
50 / 51
54 / 54
63 / 62
1050 / 1900
30 to 200 (35)
300×1000×700
36
620×790×290
41
Wired
15
9.0 / 12.5
15
10.0 / 13.5
1/2 & 1/4
25 (15)
15
R410A
1,250
20
-10 to 46
-15 to 24
UTDLFNC
1690
1/2 & 1/4
30 (15)
20
R410A
1,800
20
-15 to 46
-15 to 24
UTDLFNB
1797
Single-phase, ~230V, 50Hz
6.8 (0.9-8.0) 8.5 (2.8-10.0)
8.0 (0.9-9.1) 10.0 (2.7-11.2)
5.98 / 4.84
8.59 / 6.84
1.95 / 2.21
2.65 / 2.70
3.49
3.21
3.62
3.70
6.8/ 6.0
8.5/8.0
6.50
5.95
4.01
3.95
A++
A+
A+
A
366
500
2092
2833
1.8
2.3
32/28/24/21 36/33/30/29
32/28/24/21 36/33/30/29
55 / 56
53 / 55
57 / 57
63 / 65
68 /68
68 / 69
1360 / 2460 1700 / 3600
30 to 200 (35) 30 to 200 (47)
300×1000×700 300×1000×700
36
36
620×790×290 830×900×330
41
61
Wired
Wired
3 Core + Earth
20
20
13.5 / 18.5
17.0 / 17.0
Outdoor
5/8 & 1/4
5/8 & 3/8
30 (15)
50 (20)
20
30
R410A
R410A
1,800
2,100
20
40
-15 to 46
-15 to 46
-15 to 24
-15 to 24
UTDLFNB
UTDLFNB
2794
2357
9.4 (2.8-11.2)
11.2 (2.7-12.7)
9.03 / 7.38
2.83 / 3.07
3.32
3.65
9.4/8.7
5.81
3.81
A+
A
566
3194
2.0
36/31/28/26
33/31/28/26
54 / 55
64 / 63
69 / 70
2050 / 3800
30 to 200 (47)
300×1400×700
46
830×900×330
61
Wired
12.1 (4.0-14.0) 13.4 (4.5-14.5)
13.3 (4.2-16.2) 16.0 (4.7-16.5)
11.31 / 9.40
12.89 / 10.42
3.59 / 3.44
4.42 / 4.62
3.37
3.03
3.87
3.46
2.6
3.7
39/35/31/29 39/35/31/29
39/35/31/29 39/35/31/29
55 / 57
55 / 57
67 / 69
67 / 69
68 / 68
69 / 71
2550 / 6750 2550 / 6750
30 to 200 (60) 30 to 200 (60)
300×1400×700 300×1400×700
46
46
1290×900×330 1290×900×330
86
86
Wired
Wired
25
20.0 / 20.0
25
22.5 / 22.5
25
23.5 / 23.5
5/8 & 3/8
50 (20)
30
R410A
2,100
40
-15 to 46
-15 to 24
UTDLFNA
3393
5/8 & 3/8
50 (20)
30
R410A
3,350
40
-15 to 46
-15 to 24
UTDLFNA
3482
5/8 & 3/8
50 (20)
30
R410A
3,350
40
-15 to 46
-15 to 24
UTDLFNA
3647
Optional parts
Simple Remote Controller:
IR Receiver Kit:
External input & output PCB (with bracket):
External Connect Kit:
Remote Sensor Unit:
UTYRSNYM
UTYLBTYM
UTYXCSX + UTZGXNA
UTYXWZXZG, UTYXWZXZ3
UTYXSZX
£83
£266
£85 + £28
£8, £9
£56
Modbus Interface:
KNX Interface:
WiFi Interface:
Long Life Filter::
(Refer to page 102 for accessory combinations)
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
UTDLFNA (for ARYG36/45/54LHTBP)
UTDLFNB (for ARYG24/30LHTBP)
UTDLFNC (for ARYG12/14LHTBP)
£234
£265
£234
£61
£61
£61
Dimensions
(Unit : mm)
D
C
Ø125
Max.
850 mm
Drain hose is standard accessory
Drain port
700
631
Gas pipe
Liquid pipe
ARYG12/14LHTBP
ARYG18/24/30LHTBP
ARYG36/45/54LHTBP
A
700
1,000
1,400
B
462
762
1,162
C
650
895
1,295
D
740
1,040
1,440
Air
B
A
Top View
98
Drain port
Side View (R)
217
Side View (L)
Front View
059
SPLIT
Medium Static Pressure Duct
Standard
Single phase
(30/36/45) (24)
Features
Slim & Compact design
1,200 mm
In the case of bottom return air connection, not only does the
indoor unit design allow for installation in a narrow ceiling space
of up to 270 mm, Further space savings have been achieved by
mounting the control box as part of the chassis.
Control box is now
included as part of
the main chassis
1,135 mm
270 mm
One touch operation
and easy to install
long life filter
(Optional Parts)
Two-direction drain piping
Improves installation possibilities.
Duct indoor unit
Two-direction drain piping
Easy maintenance
Maintenance improvement is achieved by making the bottom
panel in two pieces, front and rear. The internal fan casing is
also manufactured in two pieces, namely upper and lower. The
maintenance of the motor and fan can be easily carried out by
removing the rear panel and the lower part of the casing while
leaving the main chassis installed.
See below for the case of rear suction type
Previous model
New model
1
1
3
3.Fan
4.Motor
3
2
2
Bottom panel: 2 pieces
Large bottom
panel: 1 piece
Low ambient operation
Cooling
-15°C
46°C
Heating
-10°C (24 model)
-15°C (30/36/45 model)
060
1.Control box
2.Fan casing
4
4
24°C
-15°C
Model : ARYG24LMLA / ARYG30LMLE / ARYG36LMLE / ARYG45LMLA /
ARYG36LMLA [3phase] / ARYG45LMLA [3phase]
Wired R.C.
For ARYG24LMLA
For ARYG30/36LMLE
For ARYG36/45LMLA
Specifications
Model No.
Indoor unit
ARYG24LMLA
ARYG30LMLE
ARYG36LMLE
ARYG45LMLA
ARYG36LMLA
ARYG45LMLA
Outdoor unit
AOYG24LALA
AOYG30LETL
AOYG36LETL
AOYG45LETL
AOYG36LATT
AOYG45LATT
Power Source
Cooling
Heating
Capacity
kW
UK Total / Sensible Cooling
Input Power
Cooling / Heating
EER
Cooling
COP
Heating
Pdesign
Cooling / Heating(-10°C)
SEER
Cooling
SCOP
Heating
Cooling
Class
Heating
kW
kW
W/W
kW
W/W
Cooling
Heating
Annual Energy
Consumption
kWh/a
Moisture Removal
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
dB(A)
High
Indoor(Cooling/Heating)
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
Static pressure range (Standard)
Pa
mm
Indoor
Net Dimensions
kg
HxWxD
mm
Weight
Outdoor
kg
Remote Controller Type (Supplied with unit)
Interconnecting Cable (Suggested cable size 1.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling / Heating
Amp
Power Supply To
Connection Pipe Diameter (Gas & Liquid)
Inch
Max Pipe Length (Factory Gas Charge Length)
m
Max Height Difference
Type
Refrigerant
Charge
g
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
System List Price
£
Single-phase, ~230V, 50Hz
8.5 (2.8-10.0)
9.4 (2.8-11.2)
10.0 (2.7-11.2)
11.2 (2.7-12.7)
8.41 / 6.66
9.03 / 6.72
2.65 / 2.68
2.96 / 3.10
3.21
3.18
3.73
3.61
8.5 / 8.0
9.4 / 8.7
5.90
5.70
3.90
3.80
A+
A+
A
A
504
576
2868
3202
2.5
3.0
39 / 35 / 30 / 26
39 / 35 / 30 / 26
42 / 35 / 30 / 26
42 / 35 / 30 / 26
53 / 55
54 / 55
65 / 69
65 / 70
68 / 69
69 / 70
1900 / 3600
1900 / 3800
30 to 150 (47)
30 to 150 (47)
270×1135×700
270×1135×700
40
40
830×900×330
830×900×330
61
61
Wired
Wired
3 Core + Earth
20
25
17.0 / 17.0
18.5 / 20.0
Outdoor
5/8 & 3/8
5/8 & 3/8
50 (20)
50 (20)
30
30
R410A
R410A
2,100
2,100
40
40
-15 to 46
-15 to 46
-15 to 24
-15 to 24
2467
2662
6.8 (0.9-8.0)
8.0 (0.9-9.1)
5.98 / 4.52
2.21 / 2.26
3.08
3.54
6.8 / 6.0
6.20
4.00
A++
A+
384
2098
2.5
31 / 29 / 27 / 25
31 / 29 / 27 / 25
52 / 53
60 / 62
67 / 70
1100 / 2470
30 to 150 (35)
270×1135×700
38
578×790×315
44
Wired
15
12.0 / 13.5
5/8 & 1/4
30 (15)
20
R410A
1,700
20
-10 to 46
-15 to 24
1993
3-phase, ~400V, 50Hz
10.0 (4.7-11.4)
12.5 (5.0-14.0)
11.2 (5.0-14.0)
14.0 (5.4-16.2)
9.07 / 6.39
11.38 / 7.69
2.84 / 2.87
3.89 / 3.88
3.52
3.21
3.90
3.61
10.0 / 10.0
3.21 / 3.61
5.80
4.00
A+
A+
603
3497
3.0
4.5
38 / 36 / 31 / 26 42 / 38 / 32 / 28
40 / 36 / 31 / 26 42 / 38 / 32 / 28
51 / 53
54 / 54
65 / 67
67 / 69
1800 / 6200
2100 / 6750
30 to 150 (47)
30 to 150 (60)
270×1135×700
270×1135×700
40
40
1290×900×330
1290×900×330
104
104
Wired
Wired
3 Core + Earth
10
10
8.5 / 8.5
9.5 / 9.5
Outdoor
5/8 & 3/8
5/8 & 3/8
75 (30)
75 (30)
30
30
R410A
R410A
3,450
3,450
50
50
-15 to 46
-15 to 46
-15 to 24
-15 to 24
2882
3145
12.1 (4.0-13.3)
13.3 (4.2-15.5)
11.31 / 8.53
1.33 / 1.34
3.77
3.68
3.21 / 3.61
4.0
42 / 38 / 32 / 28
42 / 38 / 32 / 28
55 / 55
2100 / 6750
0 to 150 (60)
270×1135×620
40
1290×900×330
86
Wired
25
21.0 / 21.0
5/8 & 3/8
50 (20)
15
R410A
3,350
40
-10 to 46
-15 to 24
2999
Optional parts
UTYRVNYM £104
Wired Remote Controller:
Simple Remote Controller: UTYRSNYM £83
Flange (Round):
UTDRF204
£31
Flange (Square):
UTDSF045T £42
Long Life Filter:
UTDLF25NA £95
Remote Sensor Unit:
UTYXSZX
£56
(Refer to page 102 for accessory combinations)
Drain Pump Unit:
IR Receiver Kit:
External Connect Kit:
Modbus Interface:
KNX Interface:
WiFi Interface:
UTZPX1NBA
UTYLRHYM
UTDECS5A
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
£62
£262
£14
£234
£265
£234
Max.
1000 mm
Drain pump unit
Dimensions
(Unit : mm)
3
ø200
(knock
out hole)
ø205 hole
Front view
1 Refrigerant piping flare connection (Liquid)
2 Refrigerant piping flare connection (Gas)
3 Drain piping connection
75
161
138
82
P.C.D. ø225
121
168
1
240
281
264
700
264
173 447(Bolt pitch)
264
240
138
114
66
32
1177(Bolt pitch)
Outlet
270
32
3
2
1015
1135
Top view
107
240
270
Side view (R)
Side view (L)
Rear view
061
SPLIT
High Static Pressure Duct
(60)
Single
phase
Features
High energy efficiency
Significantly greater efficiency is achieved by using all DC inverter
technology. (60 type)
Design has improved high
static pressure.
MAX.
250
MAX.
260
pa
45/54 type
Easy installation
(Compact size & Lightweight)
60 type
400
425
(unit: mm)
A compact size and lightweight indoor unit has been achieved by
reducing the basic chassis and the overall material weight.
1,050
500
1,250
45/54 type
Low noise
60 type
Low ambient operation
Cutting off the corners has enabled less turbulent airflow.
Low noise is realised by adopting a plastic case fan housing and a
plastic fan.
Plastic fan
Heat
ø225 mm exchanger
Med. noise level
43
Cooling
46°C
Heating
-15°C
24°C
dB(A)
45/54 type
Casing (Plastic)
062
pa
-15°C
-15°C
490
Model : ARYG45LHTA / ARYG54LHTA /
ARYG45LHTA [3phase] / ARYG54LHTA [3phase] / ARYG60LHTA [3phase]
Wired R.C.
ARYG45/54LHTA
ARYG60LHTA
Specifications
Model No.
Indoor unit
ARYG45LHTA
ARYG54LHTA
ARYG45LHTA
ARYG54LHTA
ARYG60LHTA
Outdoor unit
AOYG45LETL
AOYG54LETL
AOYG45LATT
AOYG54LATT
AOYG60LATT
Power Source
Cooling
Heating
Capacity
UK Total / Sensible Cooling
Input Power
EER
COP
Moisture Removal
Single-phase, ~230V, 50Hz
12.5 (4.5-14.0)
13.4 (5.0-14.5)
14.0 (5.0-16.2)
16.0 (5.5-18.0)
12.07 / 10.17
13.14 / 10.93
4.30 / 3.80
4.77 / 4.69
2.91
2.81
3.68
3.41
1.5
2.0
47 / 43 / 40
47 / 43 / 40
47 / 43 / 40
47 / 43 / 40
55 / 55
55 / 57
3350 / 6750
3350 / 6750
100 to 250 (100)
100 to 250 (100)
400×1050×500
400×1050×500
46
46
1290×900×330
1290×900×330
86
86
Wired
Wired
3 Core + Earth
25
25
22.5 / 22.5
23.5 / 23.5
Outdoor
5/8 & 3/8
5/8 & 3/8
50 (20)
50 (20)
30
30
R410A
R410A
3,350
3,350
40
40
-15 to 46
-15 to 46
-15 to 24
-15 to 24
3293
3059
kW
kW
kW
Cooling/Heating
Cooling
Heating
W/W
I/h
Indoor (Cooling)
H/M/L
Sound Pressure
Indoor (Heating)
H / M / L dB(A)
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
Static pressure range (Standard)
Pa
mm
Indoor
Net Dimensions
kg
HxWxD
mm
Weight
Outdoor
kg
Remote Controller Type (Supplied with unit)
Interconnecting Cable (Suggested cable size 2.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling / Heating
Amp
Power Supply To
Connection Pipe Diameter (Gas & Liquid)
Inch
Max Pipe Length (Factory Gas Charge Length)
m
Max Height Difference
Type
Refrigerant
Charge
g
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
System List Price
£
12.5 (5.0-14.0)
14.0 (5.4-16.2)
11.47 / 9.59
4.06 / 3.67
3.08
3.81
1.5
47 / 43 / 40
47 / 43 / 40
54 / 54
3350 / 6750
100 to 250 (100)
400×1050×500
46
1290×900×330
104
Wired
15
11.0 / 11.0
5/8 & 3/8
75 (30)
30
R410A
3,450
50
-15 to 46
-15 to 24
3205
3-phase, ~400V, 50Hz
14.0 (5.4-16.0)
16.0 (5.8-18.0)
12.85 / 10.32
4.65 / 4.37
3.01
3.66
2.5
47 / 43 / 40
47 / 43 / 40
55 / 56
3350 / 6900
100 to 250 (100)
400×1050×500
46
1290×900×330
104
Wired
3 Core + Earth
15
12.0 / 12.0
Outdoor
5/8 & 3/8
75 (30)
30
R410A
3,450
50
-15 to 46
-15 to 24
3471
15.0 (6.2-17.5)
18.0 (6.2-20.0)
13.47 / 12.77
4.70 / 5.15
3.19
3.50
2.0
45 / 40 / 36
45 / 40 / 36
56 / 58
3550 / 6900
60 to 260 (60)
425×1250×490
54
1290×900×330
104
Wired
15
12.5 / 12.5
5/8 & 3/8
75 (30)
30
R410A
3,450
50
-15 to 46
-15 to 24
3726
Optional parts
Wired Remote Controller:
Simple Remote Controller:
Long Life Filter:
Remote Sensor Unit:
IR Receiver Kit:
UTYRVNYM
UTYRSNYM
UTDLF60KA (for ARYG45/54LHTA only)
UTYXSZX
UTYLRHYM (for ARYG60LHTA only)
External Connect Kit: - Indoor
External Connect Kit: - Outdoor
Modbus Interface:
KNX Interface:
WiFi Interface:
£104
£83
£95
£56
£262
UTDECS5A
UTYXWZXZ2
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
£14
£19
£234
£265
£234
(Refer to page 102 for accessory combinations)
Dimensions
(Unit : mm)
295
14
30
425
351
181
2
3
851
1,050
Top view
85
Side view (R)
304
30
Side view (L)
1 Refrigerant piping flare connection (Liquid)
2 Refrigerant piping flare connection (Gas)
Side view (L)
28
119
146
87
1
2
921
1232
Top view
1250
3 Drain piping connection (Safety drain pan)
4 Drain piping connection(Main drain pan)
Front view
382
272
172
39
106
490
44
572
1
4
400
Rear view
1260
1192 (Bolt pitch)
1062
41
123
139
371
356
208
108
39
585
14
500(Bolt pitch)
324
71
Rear view
1,080
1,000 (Bolt pitch)
862
400
Model: ARYG60LHTA
88
526 (Bolt pitch)
Model: ARYG45LHTA /
ARYG54LHTA
Front view
152
Side view (R)
063
High Static Pressure Duct
Features
High energy efficiency
Significantly greater efficiency is achieved by using DC twin rotary
compressor, all DC inverter technology, and large heat exchanger.
(EER)
(COP)
4
4
3.25
3
3
2
2
1
1
0
ARYC72
3.60
3.40
ARYC72
ARYC90
3.20
0
ARYC90
300
5 Static Pressure selection
Max. 250 Pa
HSP mode 3
(250 Pa)
Static pressure (Pa)
Improvement and design flexibility has allowed multiple fan speeds and static
pressure modes. Low noise is achieved by adopting plastic case fan housing and
a plastic fan.
200
HSP mode 2
(200 Pa)
HSP mode 1
(150 Pa)
100
Rating
Normal (72 Pa)
0
3900
LSP mode
(50 Pa)
4300
4700
5100
5500
Airflow (m3/h)
(ARYC90L)
Outdoor unit quiet operation
A low outdoor noise operation mode allows the outdoor unit to have two quiet mode operation settings.
Peak cut operation
A peak power consumption mode controls a 4 step outdoor operation control to cut down energy usage at peak energy usage times.
Low ambient operation
Cooling
46°C
Heating
-15°C
-5°C
-15°C
064
24°C
Model : ARYC72LHTA [3phase] / ARYC90LHTA [3phase]
Wired R.C.
ARYC72LHTA
ARYC90LHTA
Specifications
Model No.
Indoor unit
ARYC72LHTA
Outdoor unit
AOYA72LALT
ARYC90LHTA
AOYA90LALT
Power Source
3-phase, ~400V, 50Hz
Cooling
Heating
Capacity
UK Total / Sensible Cooling
Input Power
EER
COP
Moisture Removal
kW
kW
kW
Cooling/Heating
Cooling
Heating
W/W
I/h
Indoor (Cooling)
H/M/L
Sound Pressure
Indoor (Heating)
H / M / L dB(A)
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
Static pressure range (Standard)
Pa
mm
Indoor
Net Dimensions
kg
HxWxD
mm
Weight
Outdoor
kg
Remote Controller Type (Supplied with unit)
Interconnecting Cable (Suggested cable size 2.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling/Heating
Amp
Power Supply To
Connection Pipe Diameter (Gas & Liquid)
Inch
Max Pipe Length (Fractory Gas Charge Length)
m
Height Difference
Type
Refrigerant
Charge
g
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
System List Price
£
20.3 (10.8-23.5)
22.6 (12.0-26.5)
19.46 / 15.22
6.25 / 6.27
3.25
3.60
4.5
47 / 44 / 41
47 / 44 / 41
57 / 57
4300 / 9300
50 to 250 (72)
450×1587×700
100
1690×930×765
215
Wired
25.0 (11.2-28.0)
28.0 (12.5-31.5)
24.33 / 19.78
7.82 / 8.24
3.20
3.40
6.0
49 / 46 / 43
49 / 46 / 43
58 / 59
4850 / 10700
50 to 250 (72)
550×1587×700
110
1690×930×765
215
Wired
3 Core + Earth
25
22.8 / 22.8
30
25.8 / 25.8
Outdoor
7/8 & 1/2
75 (20)
30
R410A
11,200
110
-5 to 46
-15 to 24
5103
7/8 & 1/2
75 (20)
30
R410A
11,200
110
-5 to 46
-15 to 24
5614
Optional parts
Wired Remote Controller:
Simple Remote Controller:
Remote Sensor Unit:
External Connect Kit: - Indoor
UTYRVNYM
UTYRSNYM
UTYXSZX
UTDECS5A
External Connect Kit: - Outdoor
Modbus Interface:
KNX Interface:
WiFi Interface:
£104
£83
£56
£14
UTYXWZXZ2
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
£19
£234
£265
£234
(Refer to page 102 for accessory combinations)
Dimensions
(Unit : mm)
Model: ARYC72LHTA
Model: ARYC90LHTA
Rear view
Rear view
Side view (R)
Air Flow
Top view
Side view (L)
Air Flow
Top view
Front view
Front view
065
SPLIT
NEW
Big Duct
Features
Separation of the fan
coil is possible by lightweight compact design
(72 class)
430 mm
420 mm
360 mm
The indoor unit can be separated into fan unit and heat-exchanger
unit to assist the installation works.
Heat exchanger unit
550mm
750mm
Fan unit
Automatic Airflow adjustment function
This function can set the optimum airflow automatically, so that
time spent balancing the airflow is considerably reduced.
Quiet operation
The combination of the V-shaped heat exchanger, air
stabiliser, and the high efficient DC fan motor allows quiet
operation despite it's small structural design.
V-shape heat exchanger
Air Stabiliser
Efficient airflow design
High efficient DC fan motor
Lower power consumption
066
Model : ARYG72LHTA / ARYG90LHTA
Future Release
Wired R.C.
Specifications
Tentative
Model No.
Indoor unit
ARYG72LHTA
ARYG90LHTA
Outdoor unit
AOYG72LRLA
AOYG90LRLA
Power Source
3-phase, ~400V, 50Hz
Cooling
Heating
Capacity
UK Total / Sensible Cooling
Input Power
EER
COP
Max. Operating Current
Moisture Removal
kW
Cooling/Heating
Cooling
Heating
Cooling/Heating
kW
W/W
A
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
$LUÁRZ5DWH
Indoor / Outdoor
High
Static pressure range (Standard)
Net Dimensions
HxWxD
Weight
Indoor
Outdoor
dB(A)
m3/h
Pa
mm
kg(lbs)
mm
kg(lbs)
Remote Controller Type (Supplied with unit)
Interconnecting Cable (Suggested cable size 2.5mm)
Suggested MCB Size
Max. Operating Current
Cooling/Heating
Power Supply To
Connection Pipe Diameter (Gas / Liquid)
Max Pipe Length (Pre-Charge)
Height Difference
Type
Refrigerant
Charge
Additional Charge
Cooling
Operation Range
Heating
System List Price
19.0 (10.8-20.9)
22.4 (12.0-24.6)
18.96 / 14.65
6.46 / 6.93
2.94
3.23
13.3 / 13.3
22.0 (11.2-24.2)
27.0 (12.5-29.2)
21.95 / 16.62
8.30 / 8.94
2.65
3.02
16/16
4.5
46*/ * / * /35*
46*/ * / * /35*
55*/55*
4300/8400
50 to 150 (72)
360×1400×850
69* (152*)
1428×1080×480
165* (363*)
Wired
6.0
47*/ * / * /35*
47*/ * / * /35*
55*/57*
4300/9000
50 to 200 (72)
360×1400×850
81* (178*)
1428×1080×480
172* (378*)
Wired
3 Core +Earth
Amp
Amp
TBC
TBC
TBC
TBC
Inch
7/8 / 1/2
100* (30)
30
R410A
7/8 & 1/2
100* (30)
30
R410A
5,600
110
-5 to 46
-20 to 24
Future Release
7,160
110
-5 to 46
-20 to 24
Future Release
Outdoor
m
g
g/m
°CDB
£
*: That specification is not fixed yet.
Optional parts
Wired Remote Controller:
Wired Remote Controller:
Simple Remote Controller:
Simple Remote Controller:
IR Receiver Unit:
Remote Sensor Unit:
External Connect Kit:
UTYRNRYZ2
UTYRVNYM
UTYRSNYM
UTYRSRY
UTYLBTYM
UTYXSZX
UTYXWZXZG
UTYXCSX + UTZGXNA
UTZPX1NAB
UTDLFNA
External input & output PCB (with bracket):
Drain Pump Unit:
Long Life Filter:
£161
£104
£83
£120
£266
£56
£8
£85 + £28
£ TBC
£61
(Refer to page 102 for accessory combinations)
Dimensions
(Unit : mm)
75
218
360
210
160
80
320
280
60
300
781
850
Ø6
Rear View
Ø4.5
100 100
P100 × 11 = 1100
1162
1400
39
31
184
25
280
339
316
210
139
Top View
Side View (L)
Side View (R)
98
66
Air Flow
29
145
210
306
277
210
Ø4.5
43
57
91
10
22
75
54
101
25
1440
1295
P100 × 12 = 1200
158
41
Front View
067
SPLIT
Floor/Ceiling
Comfort & Dual Design
Features
Flexible installation
Example for floor installation
Example for ceiling installation
Floor console
Under ceiling
Double auto swing
A combination of right/left and up/down directional swing allows
3-dimensional air direction control
Right and Left Swing
3
2
Up and Down Swing
1
2
3
4
4
1
5
5
6
7
5 steps selectable
Steps
Swing: Cooling , Dry and Fan mode
Swing: Heating and Fan mode
High power DC fan motor
7 steps selectable
Low ambient operation
• High power
• Wide rotation range
• High efficiency
Cooling 46°C
Heating 24°C
-15°C
at Heating
-10°C
068
-15°C
Model : ABYG18LVTB / ABYG24LVTA
For ABYG18LVTB
Wireless R.C.
For ABYG24LVTA
Specifications
Model No.
Indoor unit
ABYG18LVTB
ABYG24LVTA
Outdoor unit
AOYG18LALL
AOYG24LALA
Power Source
Single-phase, ~230V, 50Hz
Cooling
Heating
Capacity
UK Total / Sesible Cooling
Input Power
EER
COP
Pdesign
SEER
SCOP
Class
Annual Energy
Consumption
Cooling/Heating
Cooling
Heating
Cooling/Heating(-10°C)
Cooling
Heating (Average)
Cooling
Heating (Average)
Cooling
Heating
5.2 (0.9-5.9)
6.0 (0.9-7.5)
4.79 / 3.33
1.62/1.66
3.21
3.61
5.2/5.2
6.10
4.00
A++
A+
298
1819
2.0
43/40/34/31
43/40/34/31
50/50
57/57
62/65
780/2000
199×990×655
27 (59)
578×790×300
40 (88)
Wireless
kW
kW
kW
W/W
kW
W/W
kWh/a
Moisture Removal
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
dB(A)
Indoor(Cooling/Heating)
High
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
mm
Indoor
Net Dimensions
kg(lbs)
HxWxD
mm
Weight
Outdoor
kg(lbs)
Remote Controller Type (Supplied with unit)
Interconnecting Cable (Suggested cable size 1.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling/Heating
A
Power Supply To
Connection Pipe Diameter (Gas & Liquid)
Inch
Max Pipe Length (Factory Gas Charge)
m
Max Height Difference
Type
Refrigerant
Charge
g
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
System List Price
£
6.8 (0.9-8.0)
8.0 (0.9-9.1)
6.05 / 4.51
2.21/2.26
3.08
3.54
6.8/6.0
5.60
3.90
A+
A
425
2150
2.7
48/44/40/35
48/44/40/35
52/53
61/61
67/70
980/2470
199×990×655
27 (59)
578×790×315
44 (97)
Wireless
3 Core + Earth
16
9.0/12.5
16
12.0/13.5
Outdoor
1/4 & 1/2
25 (15)
15
R410A
1,250
20
-10 to 46
-15 to 24
1471
1/4 & 5/8
30 (15)
20
R410A
1,700
20
-10 to 46
-15 to 24
1827
Optional parts
Wired Remote Controller:
Simple Remote Controller:
External Connect Kit:
Modbus Interface:
KNX Interface:
WiFi Interface:
UTYRVNYM
UTYRSNYM
UTYXWZX
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
£104
£83
£9
£234
£265
£234
(Refer to page 102 for accessory combinations)
Dimensions
(Unit : mm)
63
47 100
56 100
58 46
2
72
1
67
124
100
80
98
162
1 Refrigerant piping flare connection (Liquid)
2 Refrigerant piping flare connection (Gas)
27
42
2 1 100 28
199
43
175
20 100
190
145
13 100
200
530
655
990
900
500
3 Drain piping connection
124
3
742
3
069
SPLIT
Ceiling
Comfort for Large Room
Single
phase
(45)
Features
Flexible installation
Open
Concealed
Various installations are possible to match the room layout.
Wall mounted
Multi auto swing
A combination of right/left and up/down directional swing allows
3-dimensional air direction control.
(Locally purchased)
Right and Left Swing
Up and Down Swing
1
5
2
3
4
2
1
4
3
5 steps selectable
5
5 steps selectable
Steps
Swing: Cooling , Dry and Fan mode
Swing: Heating and Fan mode
Fresh air intake
Fresh
air
Indoor
Low ambient operation
Cooling
Outdoor
46°C
Heating
-15°C
-15°C
070
24°C
-15°C
Model : ABYG30LRTE / ABYG36LRTE / ABYG45LRTA /
ABYG36LRTA [3phase] / ABYG45LRTA [3phase] / ABYG54LRTA [3phase]
Wireless R.C.
For ABYG30/36LRTE
For ABYG36/45/54LRTA
Specifications
Model No.
Indoor unit
ABYG30LRTE
ABYG36LRTE
ABYG45LRTA
ABYG36LRTA
ABYG45LRTA
ABYG54LRTA
Outdoor unit
AOYG30LETL
AOYG36LETL
AOYG45LETL
AOYG36LATT
AOYG45LATT
AOYG54LATT
Power Source
Capacity
Input Power
Input Power
EER
COP
Pdesign
SEER
SCOP
Class
Annual Energy
Consumption
Cooling
Heating
kW
Cooling/Heating
Cooling
Heating
Cooling / Heating(-10°C)
Cooling
Heating
Cooling
Heating
Cooling
Heating
kW
kW
W/W
kW
W/W
kWh/a
Moisture Removal
I/h
Indoor (Cooling)
H/M/L/Q
Sound Pressure Level
Indoor (Heating)
H/M/L/Q
Outdoor(Cooling/Heating) High
dB(A)
Indoor(Cooling/Heating)
High
Sound Power Level
Outdoor(Cooling/Heating) High
Indoor / Outdoor
High
m3/h
mm
Indoor
Net Dimensions
kg(lbs)
HxWxD
mm
Weight
Outdoor
kg(lbs)
Remote Controller Type (Supplied with unit)
Interconnecting Cable (Suggested cable size 1.5mm)
Suggested MCB Size
Amp
Max. Operating Current
Cooling / Heating
Amp
Power Supply To
Connection Pipe Diameter (Gas & Liquid)
Inch
Max Pipe Length (Factory Gas Charge Length)
m
Max Height Difference
Type
Refrigerant
Charge
g
Additional Charge
g/m
Cooling
Operation Range
°CDB
Heating
System List Price
£
Single-phase, ~230V, 50Hz
8.5 (2.8-10.0)
9.4 (2.8-11.2)
12.1 (4.0-13.3)
10.0 (2.7-11.2)
11.2 (2.7-12.7)
13.3 (4.2-15.5)
2.65 / 2.77
2.93 / 3.02
3.77 / 3.68
2.65 / 2.77
2.93 / 3.02
3.77 / 3.68
3.21
3.21
3.21
3.61
3.71
3.61
8.5 / 8.0
9.4 / 8.7
6.10
6.00
4.20
4.10
A++
A+
A+
A+
487
548
2662
2965
2.5
3.0
4.0
45 / 43 / 37 / 32
47 / 43 / 37 / 32
49 / 45 / 39 / 34
45 / 43 / 37 / 32
47 / 43 / 37 / 32
49 / 45 / 39 / 34
53 / 55
54 / 55
55 / 55
57 / 60
60 / 61
68 / 69
69 / 70
1660 / 3600
1900 / 3800
2100 / 6200
240×1660×700
240×1660×700
240×1660×700
46 (101)
46 (101)
46 (101)
830×900×330
830×900×330
1290×900×330
61 (134)
61 (134)
86 (189)
Wireless
Wireless
Wireless
3 Core + Earth
20
25
25
17.0 / 17.0
18.5 / 20.0
20.5 / 20.5
Outdoor
5/8 & 3/8
5/8 & 3/8
5/8 & 3/8
50 (20)
50 (20)
50 (20)
30
30
30
R410A
R410A
R410A
2,100
2,100
3,350
40
40
40
-15 to 46
-15 to 46
-15 to 46
-15 to 24
-15 to 24
-15 to 24
2363
2872
3192
10.0 (4.7-11.4)
11.2 (5.0-14.0)
2.84 / 2.87
2.84 / 2.87
3.52
3.90
10.0 / 10.0
6.10
4.10
A++
A+
573
3414
3.0
47 / 43 / 37 / 32
47 / 43 / 37 / 32
51 / 53
61 / 61
67 / 69
1900 / 6200
240×1660×700
46 (101)
1290×900×330
104 (229)
Wireless
16
7.9 / 7.9
5/8 & 3/8
75 (30)
30
R410A
3,450
50
-15 to 46
-15 to 24
2859
3-phase, ~400V, 50Hz
12.5 (5.0-14.0)
14.0 (5.4-16.2)
3.89 / 3.88
3.89 / 3.88
3.21
3.61
4.5
49 / 45 / 39 / 34
49 / 45 / 39 / 34
54 / 54
2100 / 6900
240×1660×700
46 (101)
1290×900×330
104 (229)
Wireless
3 Core + Earth
16
8.9 / 8.9
Outdoor
5/8 & 3/8
75 (30)
30
R410A
3,450
50
-15 to 46
-15 to 24
3338
14.0 (5.4-16.0)
16.0 (5.8-18.0)
4.65 / 4.67
4.65 / 4.67
3.01
3.43
5.0
51 / 48 / 42 / 38
51 / 48 / 42 / 38
55 / 56
2300 / 6900
240×1660×700
48 (106)
1290×900×330
104 (229)
Wireless
16
9.9 / 9.9
5/8 & 3/8
75 (30)
30
R410A
3,450
50
-15 to 46
-15 to 24
3507
Optional parts
Wired Remote Controller:
Simple Remote Controller:
Drain Pump Unit:
Flange
UTYRVNYM
UTYRSNYM
UTRDPB24T
UTDRF204
External Connect Kit:
Modbus Interface:
KNX Interface:
WiFi Interface:
£104
£83
£47
£31
UTYXWZX
FJRCMBS1
FJRCKNX1i
FJRCWIFI1
£9
£234
£265
£234
Max.
500 mm
(Refer to page 102 for accessory combinations)
When using UTRDPB24T
Dimensions
(Unit : mm)
130
160
192
30
150
1 Refrigerant piping flare connection (Liquid)
2 Refrigerant piping flare connection (Gas)
3 Drain piping connection
88 165
82 135
160
118
65 137
160
150
115 100
240
200
160
33 95
300
700
1660
1600
202
3
2 1 3
071
SPLIT & MULTI
SPLIT CONTROLS
SYSTEM &
OPTIONS
102 External Input and Output Table
103 Auto Louvre Grille Kit
104 Optional Parts List / Function List
For Wall Mounts and Floor Mount Units
106 Optional Parts List / Function List
For Cassettes, Ducted and Floor/Ceiling Units
108 Optional Parts List
INDIVIDUAL CONTROL
110 Wired Remote Controller (Touch Panel)
111 Wired Remote Controller
112 Simple Remote Controller
113 Central Remote Controller for 5-6 Rooms Multi
114 MODBUS® Converter
MODBUS® Interface
115 KNX® Converter
KNX® Interface
116 Wireless LAN Interface
100
SPLIT
For Light Commercial
SPLIT
For Residential
SIMULTANEOUS MULTI
For Light Commercial
MULTI SPLIT
For Residential
101
External Input and Output Table
Input
External Control
Start / Stop
Output
Peak Cut
Low Noise
Op Status
Error Status
Fresh Air
BMS/Home Auotomation *C
Aux Heater
Base Heater
KNX
Modbus
Home
Controller
WALL MOUNT
Compact
Compact
ASYG09-12LTCA*1
2
2
2
8*A
9*A
10*A
ASYG07-14LUCA*1
2
2
2
8*A
9*A
10*A
ASYG07-14LMCE*
2
2
2
8*A
9*A
10*A
ASYG18LFCA
1
1/11*A
11*A
8*A
9*A
10*A
ASYG24LFCC
1
1/11*A
11*A
8*A
9*A
10*A
ASYG30-36LMTA*3
1
1
1
8*B
9*B
10*B
ARYG07-14LLTA
3
3/11
11
3
3
8
9
10
ARYG12-18LLTB
3
3/11
11
3
3
8
9
10
PCB Terminal
7
7
7
8
9
10
Large
DUCT
Slim
Bulkhead
ARYG12-18SLAP
Medium Static
ARYG12-54LHTBP*4
7
7
7
8
9
10
ARYG24-45LMLA
3
3/11
11
3
7
8
9
10
ARYG30-36LMLE
3
3/11
11
3
8
9
10
ARYG45-60LHTA
3
3/11
11
3
3
8
9
10
ARYC72-90LHTA
3
3/11
11
3
3
8
9
10
ARYG72-90LHTA
PCB Terminal
7
7
7
8
9
10
AUYG07-09LVLA
1
1/11
11
3/*C
8
9
10
AUYG12-18LVLB
1
1/11
11
3/*C
8
9
10
AUYG24LVLA
1
1/11
11
3/*C
8
9
10
7
7
7
8
9
10
1
1/11
11
8
9
10
1
1/11
11
8
9
10
ABYG14LVTA
1
1/11
11
8
9
10
ABYG18LVTB
1
1/11
11
8
9
10
ABYG24LVTA
1
1/11
11
8
9
10
ABYG30-36LRTE
1
1/11
11
3
8
9
10
ABYG36-54LRTA
1
1/11
11
3
8
9
10
High Static
CASSETTE
Compact
Circular Flow
AUXG18-54LRLB*4
7
4 Way Flow
AUYG30-36LRLE
3/*D
FLOOR
AGYG09-14LVCA
FLOOR/CEILING
CEILING
SINGLE PHASE OUTDOOR
Wired Remote Connector £15
9705932012
Split
5
5
5
5
5
5
5
5
AOYG36-60LATT
4
4
4
4
AOYA72-90LALT
4
4
4
4
4
4
4
4
AOYG45-54LETL
Multi
AOYG36-54LBTB
3 PHASE OUTDOOR
Split
6
Multi
AOYG36-54LATT
*1 UTY-TWBXF Communication Kit required
*A Part 9705932012 required
*2 UTY-XCBXZ2 Communication Kit required
*3 UTY-XCSXZ1 Required for more than 1 input or output
*B UTY-XWNX also required
*C Cable included with UTZ-VXAA
*4 UTY-XCSX Required for more than 1 input or output
*D Cable included with UTZ-VXGA
For use with all AS and AG mode ls
when using Intesis range and
Network converter BMS options
and Wired remotes.
Communication system For SPLIT/MULTI SPLIT
External Connect Kit
For Indoor Unit
1=UTYXWZX
External Control Set
£9
For Indoor Unit
2=UTYXWZXZ5
£9
External Connect Kit
For Indoor Unit
3=UTDECS5A
£14
For Outdoor unit
4=UTYXWZXZ2
£19
For Outdoor unit
5=UTYXWZXZ3
£9
6=UTYXWZXZ4
External Connect Kit
For Outdoor unit
7=UTYXWZXZG
£8
KNX Interface
8=FJRCKNX1i
£265
Modbus Interface
Home Controller
9=FJRCMBS1
10=FJRCWIFI1
£234
Error Output Adaptor
£234
11=UTIERRW
£114
9705932012 For use with all AS
and AG models when using Intesis
range and Network converter BMS options
102
£9
Auto Louvre Grille Kit
UTD-GXSA-W / UTD-GXSB-W / UTD-GXSC-W
Features
Simple flat Auto Louvre will provide comfortable
airflow for luxury space.
Closed louvre
Opened louvre
Flexible Control
Auto Louvre Grille
• Operation with indoor unit
Auto Louvre can be operated by
synchronising the remote controller of
indoor unit.
Duct type
• UP and Down auto swing
• Auto airflow direction and auto swing
• 4 steps selectable
Wired Remote
Controller
• Auto-closing louvre
When the operation of the indoor
unit has stopped, the louvre will
automatically close.
Wireles Remote
Controller
Dimensions
W2
Unit:mm
Fitting Frame
Grille
Model Name
W1
W2
UTD-GXSA-W
683
645
883
845
UTD-GXSB-W
UTD-GXSC-W
H2
D1
D2
180
148
9
84
1,083 1,045
H2
H1
W1
H1
D1
D2
Specifications
Model name
Applicable Indoor Unit
UTD-GXSA-W
UTD-GXSB-W
ARYG07/09LLTA
ARYG12/14LLTB
ARYG12/14SLAP
ARXK07/09/12GCLH (For VRF)
ARXD04/07/09/12/14GALH (For VRF)
ARYG18LLTB
ARYG18SLAP
ARXD18GALH (For VRF)
ARXD24GALH (For VRF)
Connecting with Control box of indoor unit
Power Supply
Fixing of Auto Louvre Grille
Screw f×ing to Flange or Square Duct
Extension Square Duct Limit
1.0m (Max. duct length between indoor unit and Grille)
Net Dimension
(H × W × D)
mm
(inch)
Net
Weight
Gross
kg
(lb.)
180×683×(84+9)
[7-3/32×26-7/8×(3-5/16+11/32)]
180×883×(84+9)
[7-3/32×34-3/4×(3-5/16+11/32)]
180×1083×(84+9)
[7-3/32×42-5/8×(3-5/16+11/32)]
2.0 (4.4)
2.5 (5.6)
3.0 (6.7)
3.0 (6.7)
3.5 (7.8)
4.0 (8.9)
White
Colour
Stepping Motor
Louvre Motor
Fitting Frame, etc.
Accessories
18 to 32 (64 to 90)
°C (°F)
Cooling
Operation range
Heating
List Price
UTD-GXSC-W
% RH
80% or less
°C (°F)
16 to 30 (60 to 88)
£
135
151
187
103
OPTIONAL PARTS
SPLIT/MULTI SPLIT Optional Parts List/Function List
Wall Mounts & Floor Mount Units
Controllers/Others
Indoor unit
Outdoor unit
Wall Mounted
Type
Flagship Range
ASYG09/12
KXCA
Controllers
Wired
Remote
Controller
Designer Range
ASYG07/09/12/
14KGCA
ASYG09/12
LTCA
Standard Range
ASYG07/09/12/
14LUCA
ASYG07/09/12/
14LMCE
ASYG18LFCA,
ASYG24LFCC
ECO Range
ASYG30/36
LMTA
z
UTY-RNRYZ1
z
UTY-RNRYZ2+
UTY-TWRX
z
UTY-RLRY
z
UTY-RLRY+
UTY-TWRX
z
UTY-RVNYM
Simple
Remote
Controller
Single Phase
z
UTY-RSNYM
z
UTY-RSNYM
z
UTY-RVNYM
z
UTY-RSNYM
z
UTY-RSNYM
z
UTY-RSNYM
ASYG09/12
LLCE
Floor
5-6 Rooms
Multi
AGYG09/12/14
LVCA
AOYG36LBLA5
AOYG45LBLA6
z
UTY-RVNYM+
UTY-XWNX
z
UTY-RVNYM
z
UTY-RSNYM+
UTY-XWNX
z
UTY-RSNYM
Central
Remote
Controller
z
UTY-DMMYM
Interface
Indoor unit
Wall Mounted
Type
Flagship Range
ASYG09/12
KXCA
Designer Range
ASYG07/09/12/
14KGCA
Standard Range
ECO Range
Floor
Interface
ASYG09/12
LTCA
ASYG07/09/12/
14LUCA
ASYG07/09/12/
14LMCE
ASYG18LFCA,
ASYG24LFCC
z
UTY-TFNXZ1
z
UTY-TFNXZ1
z
UTY-TFNXZ1
z
UTY-TFNXZ1
z
UTY-TFNXZ1
z
FJ-RC-WIFI-1
z
FJ-RC-WIFI-1
z
FJ-RC-WIFI-1
z
FJ-RC-WIFI-1
z
FJ-RC-WIFI-1
ASYG30/36
LMTA
ASYG09/12
LLCE
AGYG09/12/14
LVCA
Wireless LAN
Interface
z
UTY-VKSX
KNX Converter
z
FJ-RC-KNX-1i
KNX Interface
MODBUS
Converter
104
z
FJ-RC-KNX-1i
z
FJ-RC-KNX-1i
z
UTY-VMX
z
UTY-TERX
z
FJ-RC-KNX-1i
z
UTY-VMSX
z
FJ-RC-MBS-1
MODBUS
Interface
External Switch
Controller
z
FJ-RC-KNX-1i
z
FJ-RC-MBS-1
z
FJ-RC-MBS-1
z
FJ-RC-MBS-1
External Input and Output Function/External Connect Kit/Communication Kit
Indoor unit
Wall Mounted
Type
Flagship Range
ASYG09/12
KXCA
Designer Range
Standard Range
ECO Range
Floor
ASYG09/12
LTCA
ASYG07/09/12/
14LUCA
ASYG07/09/12/
14LMCE
ASYG18LFCA,
ASYG24LFCC
ASYG30/36
LMTA
Operation / Stop
z
UTY-XWZXZ5+ UTYTWBXF
z
UTY-XWZXZ5+ UTYTWBXF
z
UTY-XWZXZ5+ UTYTWBXF
z
UTY-XWZXZ5+
UTY-XCBXZ2
z
UTY-XWZX
zUTY-XWZX
or
z{
UTY-XWZX
+ UTYXCSXZ1
+ UTZ-GXXB
z
UTY-XWZX
Forced Stop
z
UTY-XWZXZ5+ UTYTWBX
z
UTY-XWZXZ5+ UTYTWBX
z
UTY-XWZXZ5+ UTYTWBXF
z
UTY-XWZXZ5+
UTY-XCBXZ2
z
UTY-XWZX
zUTY-XWZX
or
z{
UTY-XWZX
+ UTYXCSXZ1
+ UTZ-GXXB
z
UTY-XWZX
Input
Function
ASYG07/09/12/
14KGCA
ASYG09/12
LLCE
AGYG09/12/14
LVCA
z{
UTY-XWZX
+ UTYXCSXZ1
+ UTZ-GXXB
Forced
Thermostat off
Emergency Stop
Low Noise Mode
Operation
Cooling / Heating
Priority
Outdoor Unit
Operation Peak
Control
Output
Operation Status
z
UTY-XWZXZ5+ UTYTWBXF
{
UTY-XWZXZ5+ UTYTWBXF
{
UTY-XWZXZ5+ UTYTWBXF
{
UTY-XWZXZ5+
UTY-XCBXZ2
Error Status
z
UTY-XWZXZ5+ UTYTWBXF
{
UTY-XWZXZ5+ UTYTWBXF
{
UTY-XWZXZ5+ UTYTWBXF
{
UTY-XWZXZ5+
UTY-XCBXZ2
Indoor Unit Fan
Operation Status
{
UTY-XWZX
zUTY-XWZX
or
z{UTY-XWZX
+ UTYXCSXZ1
+ UTZ-GXXB
{
UTY-XWZX
zUTY-XWZX
or
z{UTY-XWZX
+ UTYXCSXZ1
+ UTZ-GXXB
zUTY-XWZX
or
z{UTY-XWZX
+ UTYXCSXZ1
+ UTZ-GXXB
Set point attainment
status
zUTY-XWZX
Auxiliary Heater
Output
Base Heater
z: Dry Contact {: Apply Voltage
Linwood now offer an extensive range of plenum boxes to suit the Fujitsu
General Air Conditioning UK range of ducted air conditioning indoor units
Installing air conditioning ducted fan coil units (FCU's) just got easier with these
purpose made plenum boxes designed to save you time and money when fitting
VRF or split air conditioning systems
Easy to use online ordering & live order processing via
www.airconplenums.com/fujitsu-plenum
Contact details:
Linwood Plenums Ltd
138 Riverside Mansions
Milk Yard
London
E1W 3SX
Email: [email protected]
Tel: 0113 868 0410
Mob: 07946 344 474
105
OPTIONAL PARTS
SPLIT/MULTI SPLIT Optional Parts List/Function List
Cassette, Duct & Floor/Ceiling Units
Controllers/Others
Indoor unit
Cassette
Duct
4-way Flow
Compact
Circular Flow
4-way Flow
Mini
AUYG
12/14/18LVLB,
AUYG24LVLA
AUXG18/24/
30/36/45/54
LRLB
AUYG30/36
LRLE,
AUYG36/45/54
LRLA
ARYG12/14/18
LSLAP
Slim
Medium
Static
Pressure
Medium
Static
Pressure
ARYG12/14/18
LLTB
ARYG12/14/18/
24/30/36/
45/54LHTBP
ARYG24/36/45
LMLA,
ARYG30/36
LMLE
Type
Controllers
Wired
Remote
Controller
High Static Pressure
ARYG45/54/60
LHTA
ARYC72/90
LHTA
Big
ARYG72/90
LHTA
z
UTY-RNRYZ1
z
UTY-RNRYZ1
z
UTY-RNRYZ1
z
UTY-RNRYZ1
z
UTY-RLRY
z
UTY-RLRY
z
UTY-RLRY
z
UTY-RLRY
Floor/Ceiling
Ceiling
ABYG18LVTB,
ABYG24LVTA
ABYG30/36
LRTE,
ABYG36/45/54
LRTA
z
UTY-RVNYM
Simple
Remote
Controller
Others
IR Receiver
Kit
with
Wireless
Remote
Controller
z
UTY-RSNYM
z
UTY-RSRY,
UTY-RSNYM
z
UTY-RSNYM
z
UTY-RSRY,
UTY-RSNYM
z
UTY-LRHYM
z
UTY-LRHYM
For Duct For Cassette
z
UTY-LBTYM
z
UTY-LBTYC
z
UTY-RSNYM
z
UTY-RSRY,
UTY-RSNYM
z
UTY-LRHYM
(60 only)
z
UTY-LRHYM
z
UTY-LBTYM
z
UTY-RSNYM
z
UTY-LRHYM
z
UTY-LBTYM
For Cassette
z
UTY-SHZXC
Human
Sensor Kit
Cassette
Grille
z
UTY-RSNYM
z
UTY-LRHYA2
For Duct
Remote
Sensor Unit
z
UTY-RSRY,
UTY-RSNYM
z
UTY-XSZX
New amenity space can
be offered by installing
the Remote sensor.
z
UTG-UKYA-W
UTG-UKYC-W
UTG-UKYA-W
UTG-UKYC-W
z
UTD-GXSA-W (12/14)
UTD-GXSB-W (18)
Auto Louvre
Grille Kit
z
UTD-LFNA
UTD-LFNB
UTD-LFNC
Long Life
Filter
z
UTD-LF25NA
Flange
z
UTD-SF045T
UTD-RF204
Drain Pump
Unit
z
UTZ-PX1NBA
Fresh Air
Intake Kit
106
For Compact For Cassette
Cassette
z
UTZ-VXAA
z
UTZ-VXRA
z
UTZ-VXGA
z
UTD-LF60KA
(45/54)
z
UTD-LFNA
z
UTD-RF204
z
UTZ-PX1NAB
z
UTR-DPB24T
Interface
Indoor unit
Cassette
Duct
4-way Flow
Compact
Circular Flow
4-way Flow
Mini
AUYG
12/14/18LVLB,
AUYG24LVLA
AUXG18/24/
30/36/45/54
LRLB
AUYG30/36
LRLE,
AUYG36/45/54
LRLA
ARYG12/14/18
LSLAP
Slim
Medium Static
Pressure
Medium Static
Pressure
ARYG12/14/18
LLTB
ARYG12/14/18/
24/30/36/
45/54LHTBP
ARYG24/36/45
LMLA,
ARYG30/36
LMLE
High Static Pressure
Big
Floor/Ceiling
Ceiling
ABYG18LVTB,
ABYG24LVTA
ABYG30/36
LRTE,
ABYG36/45/54
LRTA
Type
Interface
z
UTZ-TFSXZ1
z
UTZ-TFNXZ1
Wireless
LAN
Interface
z
FJ-RC-WIFI-1
z
FJ-RC-WIFI-1
KNX
Converter
z
FJ-RC-KNX-1i
z
FJ-RC-KNX-1i
KNX
Interface
MODBUS
Converter
z
UTZ-TFNXZ1
z
FJ-RC-WIFI-1
z
UTY-VKSX
z
UTY-VKSX
z
FJ-RC-KNX-1i
z
FJ-RC-MBS-1
z
FJ-RC-MBS-1
z
UTZ-TFSXZ1
z
FJ-RC-WIFI-1
z
FJ-RC-KNX-1i
z
UTY-VMSX
z
UTY-VMSX
MODBUS
Interface
z
FJ-RC-WIFI-1
ARYG72/90
LHTA
ARYC72/90
LHTA
z
UTZ-TFNXZ1
z
UTY-VKSX
z
UTY-VKSX
ARYG45/54/60
LHTA
z
FJ-RC-KNX-1i
z
UTY-VMSX
z
UTY-VMSX
z
FJ-RC-MBS-1
z
FJ-RC-MBS-1
z
FJ-RC-MBS-1
External Input and Output Function/External Connect Kit/Communication Kit
Indoor unit
Cassette
4-way
Compact
Circular Flow
4-way
Mini
Slim
AUYG
12/14/18LVLB,
AUYG24LVLA
AUXG
18/24/30/
36/45/54
LRLB
AUYG30/36/
LRLE,
AUYG36/45/54
LRLA
ARYG
12/14/18
LSLAP
ARYG
12/14/18
LLTB
Operation/Stop
z
UTY-XWZX
z
PCB Terminal
z
UTY-XWZX
z
PCB Terminal
z
UTD-ECS5A
Forced Stop
z
UTY-XWZX
z
PCB Terminal
z
UTY-XWZX
z
PCB Terminal
z
UTD-ECS5A
Type
Input
Function
z
UTY-XCSX
Forced
Thermostat off
Outdoor unit
Duct
Medium
Static Pressure
High Static Pressure
Big
Floor/Ceiling
Ceiling
ABYG30/36
ABYG18LVTB,
LRTE,
ABYG24LVTA ABYG36/45/54
LRTA
ARYG12/14/18/ ARYG24/36/45
ARYG45/54/60
24/30/36/45/
LMLA,
LHTA
54LHTBP
ARY36LMLE
ARYC72/90
LHTA
ARYG72/90
LHTA
z
PCB Terminal
z
UTD-ECS5A
z
UTD-ECS5A
z
UTD-ECS5A
z
PCB Terminal
z
UTY-XWZX
z
UTY-XWZX
z
PCB Terminal
z
UTD-ECS5A
z
UTD-ECS5A
z
UTD-ECS5A
z
PCB Terminal
z
UTY-XWZX
z
UTY-XWZX
z
UTD-ECS5A
z
UTD-ECS5A
z
UTY-XCSX
z
UTY-XCSX
Simultanious Multi
AOYG36
LBTB
AOYG36/54
LATT
Low Noise Mode
Operation
z
z
UTY-XWZXZ3 UTY-XWZXZ3
Outdoor Unit
Operation Peak
Control
z
z
UTY-XWZXZ3 UTY-XWZXZ3
Output
Operation Status
{
UTY-XWZX
Error Status
Indoor Unit Fan
Operation Status
Auxiliary Heater
Output
z
UTY-VXAA*1
z
UTY-XWZXZG
or
{UTY-XCSX
+ UTZ-GXRA
z
UTY-XWZXZG
or
{UTY-XCSX
+ UTZ-GXRA
z
UTY-XWZXZG
or
{UTY-XCSX
+ UTZ-GXRA
z
UTY-XWZXZG
or
{UTY-XCSX
+ UTZ-GXRA
{
UTY-XWZX
z
UTY-VXGA*1
z
UTY-XWZXZG
{
UTD-ECS5A
z
UTY-XWZXZG
z
UTD-ECS5A
z
UTY-XWZXZG
z
UTD-ECS5A
Base Heater
z
UTY-XWZXZG
or
{UTY-XCSX
+ UTZ-GXRA
z
UTY-XWZXZG
or
{UTY-XCSX
+ UTZ-GXRA
z
UTY-XWZXZG
or
{UTY-XCSX
+ UTZ-GXRA
z
UTY-XWZXZG
or
{UTY-XCSX
+ UTZ-GXRA
{
UTD-ECS5A
{
UTD-ECS5A
{
UTD-ECS5A
z
UTY-XWZXZG
or UTY-XCSX
{
UTY-XWZX
{
UTY-XWZX
z
z
UTY-XWZXZ3 UTY-XWZXZ2
{
UTD-ECS5A
{
UTD-ECS5A
z
UTD-ECS5A
z
UTD-ECS5A
z
UTY-XWZXZG
or UTY-XCSX
z
UTD-ECS5A
z
UTD-ECS5A
z
UTY-XWZXZG
or UTY-XCSX
z
z
UTY-XWZXZ3 UTY-XWZXZ2
*1: This wire is included in Fresh air intake kit (UTZ-VXAA or UTZ-VXGA)
z: Dry Contact {: Apply Voltage
107
OPTIONAL PARTS
SPLIT/MULTI SPLIT Optional Parts
Controllers
For Individual & Centralised Control
Wired Remote Controller
UTY-RNRYZ1 / Z2
£161
Wired Remote Controller
UTY-RVNYM
£104
Central Remote Controller
UTY-DMMYM
£468
Simple Remote Controller
UTY-RSNYM
£83
UTY-RSRY
£120
For 5-6 Rooms Multi
Communication devices
Interface
Wi-Fi Interface Future Release
UTY-TFNXZ1
£143
Wi-Fi Interface
FJ-RC-WIFI-1
£234
MODBUS® Converter
UTY-VMSX
KNX® Interface
FJ-RC-KNX-1i
KNX® Converter
UTY-VKSX
£267
Wired Remote Connector
9705932012
£15
£265
£234
MODBUS® Interface
FJ-RC-MBS-1
£234
Communication Kit
UTY-TWBXF
UTY-XCBXZ2
£90
£90
For Wall Mounted type
For use with all AS and AG models
when using Intesis range and
Network converter BMS options
and Wired remotes.
Others
For Duct type
IR Receiver Kit
UTY-LRHYM
£262
IR Receiver Kit
UTY-LBTYM
£266
Remote Sensor Unit
UTY-XSZX
£56
New amenity space
can be offered
by installing the
Remote sensor.
Long Life Filter
UTD-LF25NA
£95
UTD-LFNA/UTD-LFNB £61/61
UTD-LFNC/UTDLF60KA £61/95
Flange
UTD-RF204 (Round)
UTD-SF045T (Square)
(Round)
108
(Square)
£31
£42
Drain Pump Unit
UTZ-PX1NBA
£62
For Medium Static Pressure Duct
Auto Louvre Grille Kit
UTD-GXSAW
UTD-GXSBW
£135
£151
For SPLIT/MULTI SPLIT/SIMULTANEOUS MULTI
Seperation Tube
UTP-SX236A / UTP-SX254A £72/72 UTP-SX354A
For 3-phase simultaneous multi
£97
For 3-phase simultaneous multi
For Cassette type
IR Receiver Kit
UTY-LRHYA2
£76
IR Receiver Kit
UTY-LBTYC
£98
Human Sensor Kit
UTY-SHZXC
£61
Fresh Air Intake Kit
UTZ-VXAA
£291
For Compact Cassette
Fresh Air Intake Kit
UTZ-VXRA / UTZ-VXGA
Comtest
COMTEST
£364 / £364
£40
For Cassette
For SPLIT/MULTI SPLIT/SIMULTANEOUS MULTI
External input and output PCB
UTY-XCSXZ1
£85
UTY-XCSX
£85
UTZ-GXXB
£28
For Ceiling type
For Wall Mounted type
Remote controller holder
UTZ-RXLA
External input and output PCB Box
£8
Drain Pump Unit
UTR-DPB24T
UTZ-GXRA
External input and output PCB Bracket
£53
UTZ-GXNA
£28
Service and Maintenance
£47
Service Monitoring Tool
UTY-ASSX
£239
Heat Sink Pack
HSPACK01
£POA
For ASYG09/12LLCE
109
INDIVIDUAL CONTROL
Wired Remote Controller (Touch Panel )
UTY-RNRYZ1 / Z2 (Future Release)
Refer to pages 102-107 for compatibility
Features
Easy operation by high-definition large STN-LCD touch panel screen
• Easy finger touch operation with LCD panel
• Built-in weekly/Daily timer (ON/OFF, Temp., Mode)
• Backlight enables easy operation in a darkened room
• Room temperature display
• Control up to 16 indoor units
• Corresponds to 12 different languages (English, Chinese, French, German, Spanish, Russian, Polish, Italian,
Greek, Portuguese, Turkish and Dutch)
• 2-wire type
Max. Controllable
16 indoor units
High performance and compact size
In addition to the individual control and weekly
timer, various energy saving controls can be
accessed using one remote controller only.
Individual
control
Thermo
sensor
Weekly
timer
Auto off
timer
Accurate and comfortable control
functions
Indoor temperature can be detected accurately by the
inclusion of a thermo sensor in the body of the wired
controller.
Room temperature
display
Room temperature
sensor
Various energy saving control
Custom Auto
• Maintains 2 separate set points for heating
and cooling.
• Automatically changes mode between
heating and cooling.
Cooling set temp. 27ÝC, Heating set temp. 26ÝC
Auto
Changeover
Operation Start
Change over
Cooling Set Point
Heating Set Point
Change over
Room temperature
Auto OFF timer
• The indoor unit automatically is turned off
when it reaches to the preset operating
time frame.
• The time frame of the “Auto off timer” can
be flexibly scheduled.
• Can be set off time 30 to 240 minutes
Set interval time (17:00 to 24:00)
OFF ON
ON
Auto OFF
1 hour
Normal Time
2 schedules Weekly Timer
Set Temperature Auto Return
8
Specifications
Model name
UTY-RNRYZ1 / Z2
Power Source
DC 12 V
Dimensions (H × W × D) (mm)
120 × 120 × 20.4
Weight (g)
List Price
DC12 V is supplied by the indoor unit.
110
220
£
161
Auto OFF
1 hour
Over Time
17
Set Temperature Upper and Lower Limit Setting
ON
24
Wired Remote Controller
UTY-RVNYM
Refer to pages 102-107 for compatibility
Features
Hi-grade individual control using various functions.
• 3.7-inch LCD backlight screen.
• Supporting various Energy Saving functions with simple operation.
• Multiple Language Support.
(English, German, French, Spanish, Russian, Portuguese, Italian, Greek, and Turkish)
Max. Controllable
16 indoor units
High visibility and Easy operation
Icon display (weekly time)
• Icon display of functions.
• Main functions in large icons: “Mode”, “Set Temp”, and “Fan”.
• Easy to operate by Control guide display.
• Simple operation with easy 4-way navigation pad.
Set temperature
Control guide display
High performance and compact size
• In addition to the individual control, various energy saving
controls can be accessed using only one remote controller.
Thermo
sensor
Weekly
timer
Auto off
timer
Various energy saving control
functions
Weekly Timer function
•Can be set up to 8 times per day (On/Off,
mode,Temp)
• 2 pattern settings(i.e. Summer/Winter
setting) are available.
Weekly 1
On
28°C
28
Set Temp.(°C)
Individual
control
Setting menu in
remote controller
27°C
27
26°C
26
26°C
25°C
25
26°C
25°C
24
23
Of f
22
AM10:00 PM12:00
2:00
5:00
Time
8:00
11:59
Weekly 2
26°C
Set Temp.(°C)
26
Setting menu in
remote controller
26°C
25
24
24°C
23
22
22°C
24°C
24°C
On
22°C
21
Of f
20
AM10:00 PM12:00
2:00
Auto OFF Timer
5:00
Time
8:00
11:59
Set Temperature Auto Return
Set Temperature Upper and Lower Limit Setting
Specifications
Model name
UTY-RVNYM
Power Source
DC 12 V
Dimensions (H × W × D) (mm)
120 × 120 × 21.3
Weight (g)
List Price
220
£
104
DC12 V is supplied by the indoor unit.
111
CONTROL SYSTEM CENTRALISED CONTROL
Simple Remote Controller for SPLIT & MULTI SPLIT
UTY-RSNYM
Refer to pages 102-107 for compatibility
Features
Compact remote controller provides access to basic functions
• Up to 16 indoor units can be controlled with one remote controller.
• Suitable for hotels or offices as it is easily operated with no complex functions.
• Backlight enables easy operation in a darkened room.
• 3-wire type
Max. Controllable
16 indoor units
Easy-to-use operation
• Provides access to basic operations, such as Start / Stop, Fan control, Operation mode switching, and Room
temperature setting.
• A large On / Off button is provided in the centre of the remote controller for easy operation.
• Can be used jointly with other individual remote control unit.
• Following an error display, diagnostics can be carried out on the controller.
Specifications
UTY-RSNYM
Model name
DC 12 V
Power Source
120 × 75 × 19.4
Dimensions (H × W × D) (mm)
120
Weight (g)
List Price
£
83
DC12 V is supplied by the indoor unit.
NEW
Simple Remote Controller
UTY-RSRY
Refer to pages 102-107 for compatibility
Features
Compact remote controller provides access to basic functions
• Up to 16 indoor units can be controlled with one remote controller.
• Suitable for hotels or offices as it is easily operated with no complex functions.
• Stylish design: Simple design to match the stylish interior.
• Large LCD screen & simple operation buttons
• Backlight: White colored backlight on monitor enable easy operation in dark.
• 2-wire type
Max. Controllable
16 indoor units
Corresponding to various applications
• Vertical louvre control: Vertical air flow direction can be
adjusted for Duct types with auto louvre and Cassette
types, which are installed in hotels and conference rooms,
can be adjusted.
During Cooling
• Room temperature set point limitation: The Simple
Remote Controller can manage energy saving operation in
small buildings without the central control unit.
30°C
During Heating
30°C
25°C
25°C
18°C
16°C
• Built in room temperature sensor: The Simple Remote
Controller detects actual room temperature and controls
room temperature accurately cooling and heating.
Model name
UTY-RSRY
Power Source
DC 12 V
Dimensions (H × W × D) (mm)
120 × 75 × 19.4
Weight (g)
List Price
DC12 V is supplied by the indoor unit.
112
120
£
120
Room temperature
sensor
Central Remote Controller for 5-6 Rooms Multi only
UTY-DMMYM
Features
• Batched control of up to 6 indoor units. The temperature, airflow volume, and remote control prohibition
settings of all indoor units can be batched.
• Corresponds to 9 different languages (English, German, French, Spanish, Russian, Portuguese, Italian, Greek,
and Turkish)
• Large backlight LED screen
• Large easy-to-see operation panel
System configuration
Max. Controllable
1 multi system
Max. Controllable
6 indoor units
Outdoor unit
Central Remote Controller Functions
Weekly schedule timer
The ON/OFF setting can be set for 4 times a
day. Two weekly patterns can be set to match
the cooling and heating seasons.
Monday to Friday
Summer
season
pattern
Cool
Cool
Saturday to Sunday
Cool
Cool
Cool
Cool
Time
Low noise operation
Users can choose from 4 low noise levels,
depending on the installation environment.
The operation time can be set using the timer.
7
Winter
season
pattern
23
8
23
7
1
18
22
Heat
Heat
Heat
Heat
Heat
Time
7
12 13
1
18
23
Quiet priority setting
Air
conditioning
load factor
Capacity
Prohibited Settings
The remote controller operation of all indoor
units comes with a lock function to prevent
unapproved operations in the various rooms.
The central remote controller also has a key
lock function to prevent children from playing
with it, etc
17
Heat
10ºC heat operation
When you leave, minimum heating
operation is performed to maintain the room
temperature (maintain at 10ºC).
Economy operation
Economy operation is energy saving, as the
set temperature of indoor unit is shifted by
1°C and the maximum electric value of the
outdoor unit is suppressed.
12
Heat load
100%
down
0
Operating 58dB
sound
0
time
Quiet priority low noise mode
Specifications
Model name
UTY-DMMYM
Power Source
DC 12 V
Dimensions (H × W × D) (mm)
120 × 120 × 21.3
Weight (g)
List Price
220
£
468
DC12 V is supplied by the indoor unit.
113
CONTROL SYSTEM CONVERTER/ADAPTOR
MODBUS® Converter for Indoor Unit
Refer to pages 102-107 for compatibility
UTY-VMSX
Features
The MODBUS Converter allows a complete integration of air conditioners
into MODBUS Networks.
• Simple installation due to small and compact size.
• No separate external power supply required.
• The MODBUS Converter must be connected one by one in the indoor unit.
• The MODBUS Controller permits central monitoring and control of air conditioners from
BMS/Central/Home Controller.
Max. Connectable
1
Single
indoor unit
MODBUS Network
Basic control
• Turning the units on and off
• Mode control (Heat, Cool, Dry, Auto, Fan)
• Fan speed setting
• Louvre position (Airflow direction setting)
• Room temperature setting and display
• Economy mode setting
• Error status
BMS/Central/
Home Controller
MODBUS Convertor
Lighting facilities
Security system
Automatic fire alarm interface
Windows bind
Specifications
Model name
UTY-VMSX
AC220/240V 50/60Hz
AC208/230V 60Hz
Power supply
W
Max. 1.2
Temperature
Operating / Packaged
ºC (ºF)
0~46(32~114) / -10~60(14~140)
Humidity
Operating / Packaged
%
0~95 / 0~95
mm (in.)
43 × 117 × 140
g (oz)
200(7)
£
234
Input Power
Dimensions (H×W×D)(in.)
Weight(oz)
Maximum Connectable indoor unit number per 1 MODBUS Convertor
List Price
1
MODBUS® Interface
Refer to pages 102-107 for compatibility
FJ-RC-MBS-1
Features
The MODBUS Interface allows a complete integration of air conditioners
into MODBUS Networks.
• Simple installation due to small and compact size.
• No separate external power supply required.
• The MODBUS Interface permits central monitoring and control of air conditioners from BMS.
MODBUS Network
Max. 63
MODBUS Interface
The MODBUS Interface can be used with
or without Wired Remote Controller.
BMS/Central
Controller
VRF Indoor unit
Specifications
Model name
FJ-RC-MBS-1
Dimensions (H × W × D) (mm)
Weight (g)
List Price
114
VRF Indoor unit
93×53×58
85
£
234
Wired Remote
Controller
Split Indoor unit
NEW
KNX® Converter for Indoor Unit
UTY-VKSX
Refer to pages 102-107 for compatibility
Features
It is possible to control the Split system or VRF system from central / home
controller via KNX network.
• New KNX Converter enables to connect central/ home controller and FG indoor unit.
• Compact and light weight design
KNX Converter for indoor unit
Single split indoor unit
Central / Home
Controller
Specifications
Model name
UTY-VKSX
Power supply
(DC12V)
Power consumption (W)
0.6
Dimensions (H × W × D) (mm)
43×117×140
Weight (g)
250
List Price
£
267
KNX® Interface
Refer to pages 102-107 for compatibility
FJ-RC-KNX-1i
Features
The KNX Interface allows a complete integration of air conditioners with
KNX Network systems.
• Simple installation due to small and compact size.
• No separate external power supply required (just KNX bus power).
• Can be used for single indoor units and group controlled (up to 16) indoor units.
The KNX Interface can be used with or
without Wired Remote Controller.
KNX Network
Home
Controller
Lighting
facilities
KNX
Interface
VRF Indoor unit
or
Security
system
Wired Remote
Controller
Automatic fire
alarm interface
Split Indoor unit
Windows
blind
Specifications
Model name
FJ-RC-KNX-1i
Dimensions (H × W × D) (mm)
70×70×28
Weight (g)
List Price
70
£
265
115
CONTROL SYSTEM CONVERTER/ADAPTOR
Wireless LAN Interface
UTY-TFNXZ1 / UTY-TFSXZ1
Refer to pages 102-107 for compatibility
Features
• It is the most advanced solution to remotely manage an Air Conditioning system using all types of mobile
devices such as Smartphones, PC and tablets.
• No separate external power supply required
• Can be used for single indoor units and multi system indoor units
Download Free
Wireless LAN
Interface
Internet
Indoor unit
Tablet
Smartphone
h
Router
(Locally purchased)
Smartphone
Basic control
• Turning the units on and off
• Mode control (Heat, Cool, Dry, Auto, Fan)
• Fan speed setting
• Louvre position (Airflow direction setting)
• Timer operation setting (Weekly timer)
• Economy mode setting
• Change set point temperatures
Multi system
Indoor unit
Internet
Router
(Locally purchased)
rchased))
Indoor unit
Outdoor unit
Smartphone
Multiple air conditioning management
• Multiple air conditioning management at difference
locations.
Internet
Error display & E-mail notification
• Alerts e-mail notification
• Air conditioning malfunction display
• It enables rapid service response when error
occurs.
Internet
Indoor unit
Specifications
Model name
UTY-TFNXZ1 / UTY-TFSXZ1
Dimensions (H × W × D) (mm)
71×38×15
Weight (g)
List Price
116
85
£
143 / 143
Wireless LAN Interface
FJ-RC-WIFI-1
Refer to pages 102-107 for compatibility
Features
• It is the most advanced solution to remotely manage an Air Conditioning system using all types of mobile
devices such as Smartphones, Tablets and PC
• No separate external power supply required
• Can be used for single indoor units and group controlled (up to 16) indoor units
Indoor unit
Internet
Smartphone
Smart
Wireless LAN
Interface
Tablet
Router
(Locally purchased)
PC
Basic control
• Turning the units on and off
• Mode control (Heat, Cool, Dry, Auto, Fan)
• Fan speed setting
• Louvre position (Airflow direction setting)
• Room temperature display
• Set temperature control
• Multi Language
• One Scene and Timer
(Application screen image)
Advanced control (Optional functions)
• Climate working modes (ECO, Comfort, Powerful) (future release)
• Schedule functions (ON/OFF, Modes, Set point temperature, Fan Speed, Louvre position)
• Set temperature limitation (future release)
• Multiple Scenes & Timers and Calendar function
Notifications and history
• Alerts e-mail notification (future release)
• Air conditioning malfunction alerts
• Connectivity monitoring and alerts
• History (future release)
Specifications
Model name
FJ-RC-WIFI-1
Dimensions (H × W × D) (mm)
70×108×28
Weight (g)
List Price
80
£
234
117
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project