DATA SHEET
PRODUCT DESCRIPTION:
The LC.106 and LC.151 pumps are equipped with:
 Oil check valve
 Exhaust mist eliminator
 Automatic floating oil recovery valve
 Gas ballast with manual cut-off valve
 Shock mounts
 Oil filter with by-pass
 Flexible transmission coupling
Subject to change without prior notice
Suitable for continuous operation within a pressure range of 400 mbar to 0.1 mbar (Abs) with the gas-ballast
closed.
MAIN APPLICATION FIELDS:
Vacuum packaging machines; bag filling machines; precious metal vacuum casting machines; dental field; printing
and paper industry; CNC marble and glass machines; vacuum lifting machines; workshop equipment, thermal
treatment furnaces.
NOTE:
Pump also available without motor.
Main accessories
Minor spare parts kit
Major spare parts kit
Shock mounts
Inlet filter
Stepped hose fitting
Oil level switch
Vacuum gauge
Clogged filter gauge
Clogged filter switch
Gast Manufacturing, Inc. | www.gastmfg.com
C.9603032LC106-9603033LC151 | Edition 12/27/16| Page 1/2
LC.106
K9603032
K9603032/1
LC.151
K9603033
K9603033/1
Fitted
9001018
2103015 (Ø40)
9013002 (N.O.) – 9013003 (N.C.)
9009003
9014003 + 2101001 + 2001012
9019001
LC.106 / LC.151
DATA SHEET
NOTE: Graph shows inlet pressure at a temperature of 20°C (tolerance ±10%)
LC.106
50 Hz
Subject to change without prior notice
60 Hz
50 Hz
9603032
Model number
Nominal capacity
LC.151
m³/h
106
60 Hz
9603033
127
151
181
0.1
Total final pressure (Abs) with gas ballast closed
mbar - hPa
Max inlet pressure for water vapour
mbar - hPa
11 *
11 *
kg/h
1*
1.4 *
Max water vapour pumping rate
(3~) kW
2.2 **
2.7 **
3.3 **
3.7 **
Nominal r.p.m.
n/min
1400
1700
1400
1700
Noise level (UNI EN ISO 2151 - K 3dB)
dB(A)
66
68
68
70
Weight
kg [N]
70.5 [691.6]
Motor power
Type of oil
Oil quantity
BV100 (SW100)
cod. Gast
min ÷ max dm
3
2 to 3
1-1/2”G / 1-1/4”G
Pump intake / outlet
Continuous-duty working range (Abs)
80 [784.8]
400 to 0.1
mbar - hPa
75 to 80
80 to 85
75 to 80
Operating temperature @ 20°C
°C
Required room temp. for place of installation
°C
12 to 40
Ambient temperature for storage/transport
°C
-20 to 50
Max humidity / altitude
(*) With gas ballast open.
(**) IE2 class efficiency motor.
(***) Please contact the Manufacturer if environmental conditions are different from those prescribed.
Gast Manufacturing, Inc. | www.gastmfg.com
C.9603032LC106-9603033LC151 | Edition 12/27/16| Page 2/2
80% / 1000m s.l.m. ***
80 to 85