TOP V PRO 6-10K UPS Features: • True double-conversion • Microprocessor control optimizes reliability • Input power factor correction • Output power factor 0.9 • Wide input voltage (110 V – 300 V) • Converter mode available • ECO mode for energy saving • Generator compatible • Adjustable battery number • Smart SNMP works well with either USB or RS-232 together •Comprehensive display allows easy monitoring and access of UPS status •Optional isolation transformer available. (Please check sales directly) Specifications MODEL PHASE CAPACITY* INPUT Nominal Voltage Input Voltage Range Frequency Range Power Factor OUTPUT Output Voltage Voltage Regulation Frequency Range (Synchronized Range) Frequency Range (Batt. Mode) Current Crest Ratio Harmonic Distortion AC Mode to Battery Mode Transfer Time Inverter to Bypass Waveform (Batt. Mode) EFFICIENCY AC Mode Battery Mode BATTERY Battery Type Typical Recharge Time Standard Model Charging Current (max.) Charging Voltage Battery Type Long-run Model* Charging Current (max.) Charging Voltage INDICATORS ALARM Battery Mode Low Battery Overload Fault PHYSICAL Long-run Model** ENVIRONMENT Humidity Noise Level MANAGEMENT Smart RS-232/USB Optional SNMP Standart Top V PRO 10K Single phase with ground 6000 VA / 5400 W 10000 VA / 9000 W 208/220/230/240VAC 110-300 VAC (Based on load at 50%) 176-300 VAC (Based on load at 100%) 46~54 Hz or 56~64 Hz ≧ 0.99 @ Nominal Voltage (100% load) 208/220/230/240VAC ± 1% 46~54 Hz or 56~64 Hz 50 Hz or 60Hz ± 0.1 Hz 3:1 ≦ 3 % THD (Linear Load) ≦ 5 % THD (Non-linear Load) Zero Zero Pure Sinewave 94% 90% 94% 91% 12 V / 9 Ah 9 hours recover to 90% capacity 1A/2A 218.4 VDC ±1% 273 VDC ±1% Depending on the capacity of external batteries 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) 273 VDC ±1% (Based on 20pcs batteries) Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators LCD Standard Model Top V PRO 6K Sounding every 4 seconds Sounding every second Sounding twice every second Continously sounding Dimension, D x W x H (mm) Net Weight (kgs) Dimension, D x W x H (mm) Net Weight (kgs) 369 x 190 x 688 61 369 x 190 x 318 12 442 x 190 x 688 76 442 x 190 x 318 16 0-95% RH @ 0-50°C (non-condensing) Less than 55dBA @ 1 Meter 0-95% RH @ 0-40°C (non-condensing) Less than 58dBA @ 1 Meter Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC Power management from SNMP manager and web browser CE, EN62040-1, EN62040-2, EN6100-2, EN6100-4 *1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC **Long-run model is only available in 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA). *** Product specifications are subject to change without further notice
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement