Davey ProMaster

Add to my manuals
20 Pages

advertisement

Davey ProMaster | Manualzz

ProMaster

®

Premium VSD400

Installation and

Operating Instructions

Model: PM400PV

WARNING: Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and/or property damage.

This pump requires professional expertise for installation and maintenance. The installation of this product therefore should be carried out by a person knowledgable in swimming pool plumbing requirements and who follows the installation instructions provided in this manual.

Please pass these instructions on to the operator of this equipment.

Congratulations on the purchase of a quality product from the Davey Water

Products range of Pool and Spa Equipment. You are assured of many years of reliable and super-efficient performance from your Davey ProMaster

VSD400 pump.

Read these instructions in their entirety before switching on this pump. If you are uncertain as to any of these installation and operating instructions please contact your Davey dealer or the appropriate Davey office as listed on the back of this document.

The Davey ProMaster has been designed to circulate swimming pool and spa water in conditions set out in the Australian Standard for swimming pool water quality AS 3633 or equivalent. They should not be used for any other purpose without first consulting your Davey Dealer or the Davey Customer

Service Centre.

Every Davey ProMaster is thoroughly water tested against a number of flow, pressure, voltage, current and mechanical performance parameters.

Davey’s advanced pump manufacturing technology provides reliable and efficient pumping performance that lasts and lasts.

Saving Energy with your Davey ProMaster VSD Pump:

The Davey ProMaster Pool & Spa pump is a super-efficient pump utilising a very clever, state of the art infinitely variable AC motor that provides lower levels of noise, lower operating costs and lower greenhouse emissions than traditional pool pumps.

Due to its ability to run at lower speeds than conventional pumps, your

ProMaster pump will also experience less mechanical wear and tear due to less stress on the internal mechanical components.

To achieve energy efficient pumping is easy. Simply run the filtration pump at a lower speed, but run it for longer (see table on page 8) than a conventional fixed speed pump to “turn over” your pool water for adequate filtration and sanitisation. The result is lower energy use and up to 70% lower operational costs.

2

The ProMaster Premium VSD400 has infinite speed settings from 1,050 to 3,100rpm, so you can circulate your pool or spa water at any speed in between if required. Speeds can be adjusted to power a Suction pool cleaner, In-Floor cleaning system & Pool Heaters. A Backwash setting on the pump can be selected to backwash a media filter.

What to expect with VSD Eco speed pumping (energy efficient operation) on your pool:

If your ProMaster pump is replacing a traditional AC motor pump, you will need to run it longer than your old fixed speed pump. This is NORMAL and you will save energy when using lower speed settings.

You may also notice that the pressure gauge on your filter is indicating a much lower pressure than you are used to. This is also NORMAL. The lower system pressure is simply a result of the lower speed and flow rate produced by the pump.

While running at the lower speed settings you will also notice a significant reduction in pump noise. This is a major benefit for you as it allows you to run your pump during off peak electricity tariffs, which will also assist in the reduction of your operating costs. Plus you will also have much happier neighbours.

Important considerations when running the pump on Low Flow settings:

Many pool products rely on particular minimum flow rates for best operation and/or efficiency. If you are using low flow settings on the ProMaster pump

(e.g. speed 1 to 4) Davey recommends that you check the compatibility of the speed or minimum flow rate required to run specific pool equipment such as:

• Suction pool cleaners

• Ozone generators

• Pool Heaters

• Solar Heating systems

• Salt Water Chlorinator cells

• In-floor pool cleaning systems

3

Technical Specifications:

Model

Head (m)

RPM

Enclosure Class (IP)

Insulation Class

Voltage (V)

Supply Frequency (Hz)

Motor Input Power (W / hp)

Operating Limits:

Max Water temperature

Max Ambient temperature

Dimensions:

B

C D

PM400PV

26

Speed 1 to 10 From – 1,050 to 3,100

Backwash Speed – Variable

45

F

220/240 AC

50/60

Speed Setting 1 - 120W / 0.16 hp

Speed Setting 5 - 660W / 0.89 hp

Speed Setting 10 – 1630W / 2.2hp

Backwash Setting – Variable

40°C

50°C

A

F

G

E H

I

Model A B C D

DIMENSIONS (mm)

E

PM400PV 305 670 320 350 65

F G H I

230 380 200 250

Mounting

Holes

Diameter

10

Inlet/

Outlet

PVC

40/50

Net Weight

(kg)

14

4

Installation of the ProMaster Premium VSD400 Pump:

Location

The pump should be located as close to the water as practicable and mounted on a firm base in a well drained position, high enough to prevent any flooding. It is the installer’s/owner’s responsibility to locate the pump such that the nameplate can be easily read and the pump can be readily accessed for service.

Weather Protection

It is recommended that the pump is protected from the weather. Enclosures should be ventilated to prevent condensation build-up.

Power Connection

Davey ProMaster is suitable for connection to a nominal 240 volt 50Hz power supply and is equipped with a flex and 3 pin plug. If a power outlet is not available within 3 metres of the pump, a 3 pin power point in a safe, dry place may need to be provided by an electrician. Extension cords are unsafe around pools - and should be avoided. If the supply cord of this product is damaged it must be replaced by the dealer or manufacturer, with genuine Davey spares.

This ProMaster pool pump incorporates motor overload detection designed to protect the motor from overheating. If the motor gets too hot during operation, its operating speed will reduce to bring it within a acceptable operating temperature and then will speed up to the originally set speed.

To reset the motor, switch the power off for 30 seconds, and then return the power from the mains switch.

Davey Water Products recommends that all installations are fitted with earth leakage or residual current protection devices.

CAUTION: In the interest of safety, we advise that all brands and types of pool pumps must be installed in accordance with AS3000 wiring rules or equivalent.

If the pump and filter are located below pool water level, it is necessary to fit isolating valves in the pipe between the pump and skimmer box and in return pipe from the filter to the pool.

The fittings on this product are constructed of ABS. Some PVC jointing compounds are incompatible with ABS. Check compound suitability before use.

WARNING! Ensure that an electrical isolation switch is located with easy access so that the pump can be switched off in an emergency.

5

Pipe Connection

Barrel unions are provided for connecting to the piping from the pool.

The pumps are designed to accept 40mm/50mm PVC fittings.

When plumbing the discharge pipe, ensure that the pipework does not interfere with the pumps speed dial.

The use of any pipe smaller than those specified above is not recommended.

Suction piping should be free from all air leaks and any humps and hollows which cause suction difficulties.

The discharge piping from the pump outlet should be connected to the inlet connection on the swimming pool filter (usually at the filter control valve).

Barrel unions need to be hand tightened. No sealant, glues or silicones are required.

Prior to using this pump you must ensure that:

Checklist

• Speed Setting chosen is a compatible setting with other pool equipment

• The pump is installed in a safe and dry environment

• The pump enclosure has adequate drainage in the event of leakage

• Any transport plugs are removed

• The pipe-work is correctly sealed and supported

• The pump is primed correctly

• The power supply is correctly connected

• All steps have been taken for safe operation

• The filter has been plumbed with 40/50mm pipe

6

Low Energy Operation:

Your ProMaster Premium VSD pump has speed settings from

1,050 to 3,100rpm:

- 1,050 – Lowest Speed, 1

- 3,100 – Highest Speed, 10

- Variable – Backwash Speed

• Speed 1 provides the lowest speed and therefore the greatest energy efficiency and savings. See page 9 for all other dial position speeds.

Operation

Pool Filtration

Suction pool cleaner operation

Backwashing your media filter

Manually cleaning your pool

Water Feature operation

Spa Jet operation

In-floor cleaning systems

Solar pool heating

Recommended Speed Setting

Speed 1 to 4

Speed 5 to 8

Backwash Speed

Speed 9 to 10

Guidelines for Recommended Pump Operating Hours:

Australian Standards AS3633: “Private swimming pools - water quality” states that “The minimum turnover rate shall be a single turnover of the full volume of the pool water, within the period that the pump would normally be operating….”

The table below provides a guide only to the running times of your pump while in filtration mode in order to achieve the minimum turn over rate:

Pool Size

(Litres)

20,000

30,000

40,000

50,000

60,000

80,000

100,000

Speed 1

2.4

3.7

4.9

6.1

7.4

9.8

12.3

Speed Setting (hours)

Speed 5

1.3

2.0

2.7

3.3

4.0

5.3

6.7

Speed 10

0.9

1.4

1.9

2.3

2.8

3.8

4.7

Barrel unions need to be hand tightened. No sealant, glues or silicones are required.

7

Features & Functionality

Your ProMaster Premium VSD 400 pool pump has several operational features. The following explain each of these.

Programmable Boost Cycling for every hour of operation

-

For running the pump at full speed (Boost) for a pre-determined time for every hour of operation

-

Selectable times are 5, 10 & 15 minutes cycles via dip switch settings under the motor cover or via RJ45 digital input. (See pages 10 to 13 for diagrams and settings)

-

Ideal for In-floor pop-up cleaning systems and agitating debris to the pool surface for collection in the pool skimmer box

Multi-Coloured LED indicator light

-

Used for identifying required settings for programming time for full speed (Boost) cycling and warnings:

>

Solid Green = Normal Dial Operation

>

Slow Flashing Green = Backwash

>

Fast Flashing Green = Boost Cycling & AUX External Control

>

Solid Amber = Speed Compensation Active

>

Slow Flashing Amber = Time to Backwash

>

Fast Flashing Red = Fault detected - reset pump

Constant Flow/Speed Compensation

-

Helps to overcomes friction loses experienced as debris builds up in your media filter or cartridge filter

-

Saves on energy running costs, due to the pump running at minimum turnover flow rate, between backwashes

Patented water cooled design for smooth and super quiet operation

-

The pump has a water cooled membrane and jacket around the motor which helps to keep the pump cool during operation

-

Waste heat off the motor is transferred into the pool water, helping to reduce pool heating energy costs

8

Weatherproof RJ45 Communication Port

(See page 10 for connection details)

-

For communication and connecting to external Pool Control systems

-

For receiving a signal from a Heat Pump or Gas Heater to ramp the

VSD pump speed to full during the heating process

-

Service diagnostics and software updates (For Davey use only)

Backwash Speed Cycling Technology

-

When in backwash mode the pump will cycle between a low and high speed to help air-rate and agitate the filter media for a more effective clean

-

Reduces wasted water during the backwash cycling process

Full variable frequency drive with user friendly selectable speed dial

-

Provides for easy selection of desired filtration speed

-

No complicated digital push button controls

Large 4.5 litre lint pot

-

Provides for longer intervals between cleaning

9

Advanced Setup

External AUX Connections Overview

Your ProMaster Premium has an RJ45 style waterproof socket to allow for external control of motor speed and other functionality. A standard RJ45 network cable (without boot) can be used. Simply remove the connector from one end and feed the cable back through the waterproof housing.

Tighten this cap to RJ45 socket

Figure 1: RJ45 Plug Installed in housing (from rear)

Tighten this nut

It is recommended to keep the cable length between the pump and external pool controller or heater as short as possible.

There are two major pin configurations as shown below:

RJ45 PINOUT

Figure 2: RJ45 Pin connections

6

7

8

4

5

2

3

Pin Function

1 RS485 +ve

RS485 -ve

Digital Input 3

Analogue Input

0V Ground

Digital Input 2

Digital Input 1

24V

T-568A

Green/White

Green

Orange/White

Blue

Blue/White

Orange

Brown/White

Brown

10

T-568B

Orange/White

Orange

Green/White

Blue

Blue/White

Green

Brown/White

Brown

Check that the cable you use has the above colour coding pins 1 through to 8. If an alternative colour coding has been used make sure to record the colour which corresponds to each pin to avoid misconnection at the pool controller or heater. If an alternative cable is used make sure the analogue input and ground are a twisted pair.

The 24V connection is only to be used as a reference for the digital inputs –

DO NOT power external equipment from this supply rail.

Digital Control Inputs

The 3 digital inputs allow for overriding the dial speed setting. To set one of these inputs either:

1. Connect an isolated 24V supply between ground and the digital input pin

2. Connect the switched contacts of a relay between the 24V pin and the

digital input

The fixed speeds (as a proportion of full speed) are:

Input 1 (Pin 7) Input 2 (Pin 6) Input 3 (Pin 3) Output Speed

0 0 0 Dial

0

0

0

24V

0

24V

24V

0

24V

0

24V

0

33%

50%

Backwash

100%

24V

24V

24V

0

24V

24V

24V

0

24V

67%

83%

Change Boost Time

11

Interfacing equipment to the Promaster Premium VSD400

WARNING: A qualified electrician is required to carry out the work shown below.

Promaster Premium VSD400 can be controlled by other equipment to turn it on to high speed (or any other preset speeds, contact Davey for details).

This is to achieve maximum efficiency, for example, when using a gas heater, or a heat pump.

If the equipment has an isolated 18- 24V DC signal output, simply connect pin 7 to 24V DC positive and pin 5 to DC ground as shown in the following diagram:

Pin7 (Brown/White)

+ 18 ~ 24V DC

To RJ45 Socket of VSD Pump

Pin5 (Blue/White)

DC Ground

Controlling Equipment

If the controlling equipment does not have 18-24VDC voltage output as above, and it has 24VAC, 230VAC, 12AC or 12 DC etc. signal output, a suitable relay

(the coil voltage must be the same as the signal output voltage of the controlling equipment) can be used to do this job as mentioned above, and shown in the following diagram:

Pin7 (Brown/White)

To RJ45 Socket of VSD Pump

Pin8 (Brown)

Relay (Dry)

Contact

Relay Coil, must be the same voltage as the equipment signal output

Controlling Equipment

If the controlling equipment already has the relay output(dry contact) for controlling purpose, an extra relay is not necessary, simply connect Pin 7

(Brown/White) and Pin 8 (Brown) to the dry contacts as shown in the left part of the diagram above.

12

Programming Boost Cycle Time via Digital Inputs

Boost cycle time can be changed via digital input on the RJ45 Aux connector.

To change cycle time connect digital inputs 1, 2 and 3 to 24V. The periodic agitation time will cycle to the next setting. The dial LED will flash amber the number of times corresponding to the updated setting.

2

3

Setting

1 (default)

4

Time to Run at 100% per hour of operation

0

5 minutes

10 minutes

15 minutes

Analogue Control Input

Speed control can also be achieved by connecting a 0-10V signal at the input on pin 4 (ground at pin 5). As soon as a signal above 0V is registered, this input will take priority over dial settings.

Pin4 (Blue)

+ 0~ 10 V DC Signal Output of controlling equipment

To RJ45 Socket of VSD Pump

Pin5 (Blue/White) DC Ground

Controlling Equipment

RS485

RS485 inputs are reserved for Davey service connection and software updates.

Programming Boost Cycling Time via DIP Switches

As an alternative to using digital inputs, boost cycle time can be changed via internal PCB board with DIP switches. (Please contact your nearest

Davey Dealer or Davey for advice).

13

Using your ProMaster Premium VSD pump with a Davey Salt Water Chlorinator

Davey ChloroMatic, EcoSalt & EcoMineral salt water chlorinators require a minimum flow rate of 80 litres per minute (lpm) through the chlorinator cell for best efficiency and cell life. Please refer to the performance graph below as a reference for the flow in your pool and refer to the pressure indicated by the gauge on the media or cartridge filter.

Ensure flow rate is sufficient to cover your chlorinator cell plates completely at all times of operation.

ProMaster - PM400PV

Performance

25

20

15

Dial position No. 10

Dial position No. 9

Dial position No. 8

Dial position No. 7

Dial position No. 6

Dial position No. 5

Dial position No. 4

Dial position No. 3

Dial position No. 2

Dial position No. 1

10

5

Speed

Setting

Dial 1

Dial 2

Dial 3

Dial 4

Dial 5

Dial 6

Dial 7

Dial 8

Dial 9

Dial 10

0

0 50 100 150 200

Flow ( lpm )

250

hp

0.17

0.28

Input

0.46

0.69

0.97

1.21

1.61

1.97

2.17

2.21

1201

1469

1620

1650

W

125

207

343

514

724

905

300

hp

Output

0.12

W

87.5

0.19

144.9

0.32

0.48

0.68

0.85

240.1

359.8

506.8

633.5

1.13

1.38

1.58

1.64

840.7

1028.3

1180

1220

14

350 400

Duty

Point

1.2

1.8

2.6

3.6

4.7

5.4

6.7

7.8

7.9

8

450

Flow

Rate

146

178

218

255

290

314

348

373

378

380

Operating your Suction Pool Cleaner

Before installing or purchasing a pool cleaner for use with your ProMaster pool pump, it is important to know the minimum flow rates required for it to operate effectively.

To operate a suction pool cleaner with your

ProMaster Premium VSD400 pump:

1. Activate the High Flow setting (10) and allow the pump to fully prime by running for around 2 minutes. You will know the pump is primed when you can see a strong flow of water through the clear leaf basket lid.

2. When all air is expelled from the leaf basket, connect the pool cleaner hose firmly into the skimmer plate or dedicated wall suction.

3. Select the speed setting that enables best performance from your suction pool cleaner. Speed 3 to 7 should be ample for most cleaners, however if the cleaner requires better performance, select speeds 7 to 10. A Davey

PoolSweepa suction pool cleaner is recommended to run between speeds

2 to 3.

4. The cleaner should only be connected for as long as is required to clean the surface of your pool. When cleaning is complete, disconnect the cleaner and remove the skimmer plate from the skimmer box.

NOTE: To get optimum energy efficiency from your ProMaster DO NOT keep the suction pool cleaner connected when cleaning is not required.

5. Reactivate the most efficient speed setting for daily filtration. Speeds 1 to 4 is recommended.

Maintenance: Emptying the Strainer Basket

The strainer basket should be inspected frequently through the transparent lid and emptied when a build up of rubbish is evident. The directions below should be followed.

1. Switch off pump.

2. Unscrew the strainer basket lid anti-clockwise and remove.

3. Remove the strainer basket by lifting upwards from its housing.

4. Empty the trapped refuse from the basket. Hose out with water if necessary.

NOTE: NEVER knock the plastic basket on a hard surface as it will cause damage.

15

5. Check the strainer basket for cracks, replace the strainer basket in the pump if OK.

6. Replace the lid and ensure that it seals on the large rubber o-ring. Firm hand tightness only is required. The o-ring & thread can be lubricated with Hydra slip or equivalent products.

Failure to undertake regular maintenance may cause damage not covered by warranty.

Power supply to this pump needs to be through an RCD, having a rated leakage current not exceeding 30mA.

16

Trouble Shooting

If the pump runs but there is no water flow or water flow is reduced, the following condition may apply:

1. The filter requires backwashing or it is blocked. Refer to the relevant section in the Filter Manual.

2. The pump is not primed. Re-prime as per instruction in ‘Starting the pump’

3. There are air leaks in the suction piping. Check all piping and eliminate leaks, also check for a loose strainer basket lid. Air bubbles in the water flowing back to the pool would indicate a leak in the suction to the pump allowing air to enter the pipework.

4. A leaking pump shaft seal may also prevent operation. Evidence of this would be water on the ground under the pump.

5. The pump is not able to get water from the pool. Check that the valves to the pump are fully open and that the pool water level is up to the skimmer box.

6. Blockage in the piping or pump. Remove the strainer basket and check for any blockage to the pump impeller entry. Check the skimmer box for blockage.

If the pump does not operate, the following conditions may apply:

1. The power is not connected. For 240 volt only, check the power point by plugging in a portable appliance to ensure power is available. Also check fuses and the main power supply switch

2. Automatic overload is tripped. The pump has an in-built thermal overload which will reset automatically after the motor has cooled following an overheating period. Determine the cause of the overload tripping and rectify.

Reset the pump by switching the power OFF for 30 seconds.

3. Blockage is preventing the pump from rotating.

17

Removal of the Pump from Pipework

Should it be necessary to remove the pump, follow these instructions:

1. Switch off the power and remove the plug from the power source.

NOTE: If the pump is wired into a time clock or another automatic control, the wiring should be removed by a qualified technician.

2. Close the water valves on the pool return and the pump inlet pipework.

3. Remove the discharge & suction barrel unions taking care not to lose the o-rings.

4. Move the pipework with the barrel unions attached until the pump can be pulled clear.

NOTE: When making any enquiries about your ProMaster be certain to quote the model number from the nameplate located on the motor.

Water Quality

Maintaining balanced water chemistry is important to the life of your pool pump. This pump is designed to be used with Pool & Spa water, balanced in accordance with Langlier Saturation Index, with a pH level of between 7.2 and 7.6 and is regularly treated with a chlorine sanitising agent with the level not exceeding 3.0 ppm.

Please consult your local pool shop regularly to have your water tested.

18

POWER CONNECTIONS AND WIRING MUST BE CARRIED OUT BY

AN AUTHORISED ELECTRICIAN.

DANGER - Hazardous suction. Do not block water entry into filtration system with any part of your body as the pressure can trap hair or body parts, causing severe injury or death. Do not block suction. Turn off pump immediately if someone becomes trapped.

Caution! Do not add chemicals directly to the pool skimmer. Adding undiluted chemicals may damage pump and filter and void warranty.

Routine Maintenance tasks - to maximise the life of your pool equipment

& personal safety, use this checklist once a week. Turn pump off first.

a. Make sure that any pressure gauges are in working condition and the operating pressure is within limits as specified on the product.

b. Make sure that each suction inlet, and main drain has a cover that is securely attached and in safe working condition.

c. Make sure that all skimmer covers are securely attached and in safe working condition. These should be replaced every 3 to 4 years.

d. Remove any obstructions or debris from the main drain cover.

e. Ensure the skimmer baskets and the pump hair and lint pots are free of leaves and debris at least once a week.

f. Remove obstructions and combustibles from around the pump motor.

g. Make sure all wiring connections are clean and that all wiring and electrical equipment is in good condition. Damaged wiring must be repaired or replaced by a qualified electrician as soon as damage is discovered.

h. Check water balance and sanitiser levels at your local pool shop.

WARNING! Pump suction is hazardous and can trap and drown or disembowel bathers. Do not block suction. Do not use or operate swimming pools, spas or spa baths if a suction cover is broken, missing or loose. Two suction covers and inlets must be provided into every pump to avoid suction entrapment.

In accordance with AS/NZS60335.2.41 we are obliged to inform you that this appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.

- children shall not play with the appliance

- cleaning and user maintenance shall not be made by children without supervision

- the maximum total head, in meters (for pumps having a rated power input exceeding 50W)

Davey Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction within warranty periods beginning from the date of original purchase due to faulty materials or manufacture, Davey will at our option repair or replace it for you free of charge, subject to the conditions below.

Should you experience any difficulties with your Davey product, we suggest in the first instance that you contact the Davey Dealer from which you purchased the Davey product. Alternatively you can phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New

Zealand, or send a written letter to Davey at the address listed below. On receipt of your claim,

Davey will seek to resolve your difficulties or, if the product is faulty or defective, advise you on how to have your Davey product repaired, obtain a replacement or a refund.

Your Davey Three Year Guarantee naturally does not cover normal wear or tear, replacement of product consumables (i.e. mechanical seals, bearings or capacitors), loss or damage resulting from misuse or negligent handling, improper use for which the product was not designed or advertised, failure to properly follow the provided installation and operating instructions, failure to carry out maintenance, corrosive or abrasive water or other liquid, lightning or high voltage spikes, or unauthorised persons attempting repairs. Where applicable, your Davey product must only be connected to the voltage shown on the nameplate.

Your Davey Guarantee does not cover freight or any other costs incurred in making a claim.

Please retain your receipt as proof of purchase; you MUST provide evidence of the date of original purchase when claiming under the Davey Guarantee.

Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, damage or injury of any kind whatsoever arising directly or indirectly from Davey products.

This limitation does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to your Davey product under the Australian or New Zealand legislation and does not affect any rights or remedies that may be available to you under the Australian or New Zealand Consumer Legislation.

In Australia, you are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Should your Davey product require repair or service after the guarantee period; contact your nearest Davey Dealer or phone the Davey Support Centre on the number listed below.

For a complete list of Davey Dealers visit our website (davey.com.au) or call:

Davey Water Products Pty Ltd

Member of the GUD Group

ABN 18 066 327 517

AUSTRALIA

Head Offi ce

6 Lakeview Drive,

Scoresby, Australia 3179

Ph:

Fax:

1300 232 839

1300 369 119

Email: [email protected]

Website: davey.com.au

INTERNATIONAL

Australian Head Offi ce

Ph:

Fax:

Email: [email protected]

Website: davey.com.au

EUROPE

+613 9730 9124

+613 9753 4248

ZAC des Gaulnes

355 Avenue Henri Schneider

69330 Meyzieu, France

Ph:

Fax:

+33 (0) 4 72 13 95 07

+33 (0) 4 72 33 64 57

Email: [email protected]

Website: daveyeurope.eu

NEW ZEALAND

7 Rockridge Avenue,

Penrose, Auckland 1061

Ph:

Fax:

0800 654 333

0800 654 334

Email: [email protected]

Website: daveynz.co.nz

NORTH AMERICA

Ph: +1 866 328 7867

Email: [email protected]

Website: daveyusa.com

MIDDLE EAST

Ph:

Fax:

+971 50 6368764

+971 6 5730472

Email: [email protected]

Website: daveyuae.com

® Davey is a trademark of Davey Water Products Pty Ltd. © Davey Water Products Pty Ltd 2016.

P/N 402917-1

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement