16_0111 MW-MAM_LL Design criteria.indd
STARBUCKS COFFEE COMPANY
MIDWEST/ MID-AMERICA LANDLORD DESIGN INTENT
SITE & BUILDING PLAN CRITERIA
THIS PACKAGE IS CONFIDENTIAL AND SHALL REMAIN THE SOLE PROPERTY OF STARBUCKS CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS DESIGN INTENT FOR A PROTOTYPICAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE
AT ANYTIME) AND DO NOT REFLECT ACTUAL SITE CONDITIONS. REFERENCE WORK LETTER AND TENANT DRAWINGS FOR PROJECT SPECIFIC
INFORMATION.
STARBUCKS TEMPLATE VERSION 2017.01.17
INDEX OF SHEETS:
PROTOTYPICAL SINGLE TENANT BUILDING: SITE PLAN REQUIREMENTS _____________________ 2
PROTOTYPICAL SINGLE TENANT BUILDING: FLOOR PLAN _________________________________ 3
PROTOTYPICAL SINGLE TENANT BUILDING: EXAMPLE UNDERGROUND PENETRATIONS _________ 4
PROTOTYPICAL SINGLE TENANT BUILDING: ROOF AND HVAC PLAN _________________________ 5
PROTOTYPICAL END CAP / MULTI-TENANT BUILDING: SITE PLAN REQUIREMENTS _____________ 6-7
PROTOTYPICAL END CAP / MULTI-TENANT BUILDING: FLOOR PLAN _________________________ 8
PROTOTYPICAL END CAP / MULTI-TENANT BUILDING: EXAMPLE UNDERGROUND PENETRATIONS__ 9
PROTOTYPICAL END CAP / MULTI-TENANT BUILDING: ROOF AND HVAC PLAN _________________ 10
TRASH ENCLOSURE AND SCREEN DETAILS ____________________________________________ 11
DRIVE THRU EQUIPMENT DETAILS___________________________________________________ 12-14
ENLARGED PATIO PLAN ___________________________________________________________ 15
LANDSCAPE EXAMPLES ___________________________________________________________ 16
SITE SIGNAGE AND PAVEMENT GRAPHIC DETAILS ______________________________________ 17
BUILDING DRIVE-THRU BUMP OUT DETAILS ___________________________________________ 18
DRIVE-THRU WINDOW SPECIFICATION _______________________________________________ 19-20
DRIVE-THRU WINDOW SHELF CUT SHEET _____________________________________________ 21
EXAMPLE BRAND SIGNAGE ________________________________________________________ 22-24
AWNING AND CANOPY DETAILS _____________________________________________________ 25
EXAMPLE OF POSSIBLE SIGNAGE LOCATIONS __________________________________________ 26-27
BIKE RACK CUT SHEET ____________________________________________________________ 28
VEHICLE DETECTOR LOOP CUT SHEET ________________________________________________ 29-30
C
O
N
S
TR
U
C
TI
O
N
CONCRETE DT LANE
ENDS 12' AFTER DT
BUMPOUT
ILLUMINATED
BOLLARD
ILLUMINATED
ILLUMIN
BOLLARD
DRIVE THRU
STRIPING
ILLUMINATED
BOLLARD
20'-0"" MIN.
A
ALTERNATE DRIVE THRU
EXIT TO MAIN STREET
TIMER LOOP
12" MIN.
ONE CAR LENGTH
REQUIRED AFTER
PICKUP
TRASH AND RECYCLING ENCLOSURE.
DEDICATED OR EQUIVALENT 20' WIDE
X 12' DEEP MINIMUM. SEE PAGE 11
FOR MORE INFORMATION. PROVIDE
CONCRETE PAD AS SHOWN.
LANDSCAPE
BARRIER BETWEEN
PATIO AND
DRIVING/PARKING
SURFACES
ILLUMINATED
BOLLARD
BOH DOOR
LANDSCAPING
LANDLORD, SEE
LANDLO
DETA
DETAIL 5 PAGE 11
20 INSIDE RADIUS
20'
MINIMUM, 22' PREFERRED
PATIO DOOR
BIKE
KE RACK: QUANTITY
TO REFLECT WORK
LETT
LETTER
PATIO - 250 TO 350 SF.
SEE WORKLETTER.
PROVIDE (1) HOSE BIBB
AND (2) OUTLETS.
LOCATE PER TENANT
DIRECTION
PATIO RAILING,
NO OPENING TO
DRIVE THRU
OPTION 01: GREASE
INTERCEPTOR
5 PANEL MENU BOARD FREE
STANDING DT EVOLVED.
CONCRETE DT LANE
12' WIDE MINIMUM
ORDER POINT CANOPY WITH
DIGITAL ORDER SCREEN
DT EVOLVED. DO NOT
LOCATE ON CURVE. FINAL
LOCATION PER TENANT
DRAWINGS.
TIMER LOOP
BOLLARD
PRE-MENU BOARD FREE
STANDING DT EVOLVED
18" MIN. TYP.
STAR PATTERN AT DT
ORDER POINT
CONCRETE DT LANE
STARTS 12' BEFORE ORDER
POINT CANOPY
ENTRY
RY
ILLUMINATED
BOLLARD
100’ (6 CAR STACK) MEASURED
12' - 0"
A FROM C.L. OF DT ORDER POINT
BOLLARD
EXIT ARROW AND
STRIPE (WHITE)
CLEARANCE BAR FREE
STANDING DT EVOLVED
SIGN - ILLUMINATED
MONUMENT DT EVOLVED
N
O
T
SIGN - DT DIRECTIONAL
ILLUMINATED
SITE LIGHTIN
LIGHTING: 1.5
FOOTCANDLES MINIMUM
FOOTCAN
FOOTCAND
THROUG
THROUGHOUT SITE. (TYPICAL)
ENTER PAVEMENT
ARROW AY DT ENTRANCE
(GREEN) (TYPICAL)
STARBUCKS MINIMUM PARKING
RECOMMENDATIONS:
- 18 STANDARD
- 2 ACCESSIBLE
- 20 TOTAL
SIGN - ILLUMINATED
MONUMENT DT EVOLVED
SAMPLE SINGLE TENANT BUILDING: SITE PLAN REQUIREMENTS
OPTION 02: GREASE
INTERCEPTOR
Ramp
ENTER PAVEMENT ARROW
(GREEN) (TYPICAL)
SIGN - DT DIRECTIONAL
ILLUMINATED
FO
R
EXIT PAVEMENT ARROW
(WHITE) (TYPICAL)
TO C.L. DT BUMP OUT
BYPASS LANE
WHEEL
STOP,
TYP.
SIGN - DT DIRECTIONAL
ILLUMINATED. FINAL LCOATION
PER TENANT DRAWINGS, TYP.
+/- 2,000 SF
- SEE SPECS AND DETAILS FOR STARBUCKS BRANDED PAVEMENT GRAPHICS.
2
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
1
17
TR
U
DIRECTION OF WINDOW
SLIDE TO BE IN DIRECTION
OF CAR TRAVEL.
10'-1" MINIMUM
GREASE LINE FOR
EXTERNAL GREASE
INTERCEPTOR.
3' - 6" DOOR
400 AMP ELECTRICAL
PANELS, MINIMUM QUANTITY
(2) OR PER WORK LETTER
C
O
ENGINE
LOCATION MAY VARY
SANITARY LINE
N
S
LL TO LL WALL
D.W. LINE
PROVIDE NATURAL COLOR CONCRETE.
GRIND AND SEAL WITH SHERWIN WILLIAMS
REXTHANE, 2 COATS WITH SHARK BITE
GRIP DURING 2ND COAT REQUIRED.
I
INTERIOR
PARTITION
WALLS TO ROOF DECK
R
EXPOSED DECK / STRUCTURE MINIMUM
M
13'-0" AFF.MINIMUM WEB OPENING TO
O
ACCOMODATE DUCT WORK
CT CABINET WITH DISCONNECT
GAS METER
THIRD ELECTRICAL
PANEL IF REQUIRED
FO
FURRED OUT WALL,
LL
LL,
VARIES PER CONDITION
NDITION
OPTION 01: ROOF HATCH
(PREFERRED)
4'-0" MIN.
T
BUILDING SHELL,
VARIES PER LANDLORD
OPTION 02: ROOF ACCESS
LADDER
STORE FRONT
3/8" (10MM) METAL EDGE
OR SIMILAR FOR DESIGN
INTENT. SLIDE METAL
LEG UNDER MAT. CLIP
LEG EDGE AS NEEDED
TO FIT A CURVE.
VESTIBULE AS REQUIRED
PER TENANT PLANS
STOREFRONT DOOR AND
THRESHOLD
RECESSED WALK-OFF
MAT, MAINTAIN 6"
SETBACKS.
NEW WALK OFF MAT
WATERPROOF MEMBRANE,
(ONLY IF ON WOOD
SUBFLOOR)
LOCATION MAY VARY
CONCRETE FLOORING
SAMPLE SINGLE TENANT BUILDING: FLOOR PLAN
3
|
STARBUCKS COFFEE COMPANY
|
+/- 2,000 SF
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
1
|
TRANSITION - CONCRETE /WALKOFF MAT
Scale:
176
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
N
O
TI
C
ENGINE
PLUMBING AND ELECTRICAL STUB
UPS AT FRONTBAR, TYPICAL. FINAL
QUANTITY AND LOCATIONS TO BE
PER TENANT DRAWINGS
C
O
N
S
TR
U
FLOOR SINK/DRAIN, TYPICAL.
FINAL QUANTITY AND
LOCATIONS TO BE PER
TENANT DRAWINGS
SANITARY LINE
GREASE LINE FOR
EXTERNAL GREASE
INTERCEPTOR.
INTERIOR PARTITION
INT
WALLS TO ROOF DECK
W
FO
R
PROVIDE NATURAL COLOR CONCRETE.
TE.
GRIND AND SEAL WITH SHERWIN WILLIAMS
WILLIAM
RK
K BITE
REXTHANE, 2 COATS WITH SHARK
UIRED.
GRIP DURING 2ND COAT REQUIRED.
DOMESTIC WATER LINE
FURRED OUT WALL,,
VARIES PER CONDITION
DITION
N
O
T
BUILDING SHELL,
VARIES PER LANDLORD
SAMPLE SINGLE TENANT BUILDING: EXAMPLE UNDERGROUND PENETRATIONS
4
|
STARBUCKS COFFEE COMPANY
|
+/- 2,000 SF
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
N
= ZONES FOR ROOFTOP EQUIPMENT
O
TI
ROOF PENETRATIONS TO MAINTAIN CLEARANCE
FROM INTERIOR PARTITION THAT SEPARATES
FRONT OF HOUSE AND BACK OF HOUSE
NOTE: DISTANCE FROM PARAPET WALL TO
BE DETERMINED BY LOCAL BUILDING CODE
REQUIREMENTS
C
O
N
S
TR
U
C
ARCHITECTURAL CANOPY
WITH RECESSED LED CAN
LIGHTING AND INTERNAL ROOF
DRAIN TO STORM SEWER
MINIMUM
4' - 0"
OCATIONS
REFER TO TENANT DRAWINGS FOR RTU SIZES AND LOCATIONS
EXPOSED DECK / STRUCTURE MINIMUM
13'-0" AFF.MINIMUM WEB OPENING TO
ACCOMODATE DUCT WORK
ROOF PENETRATIONS TO MAINTAIN CLEARANCE
FROM INTERIOR CEILING FRAMING BELOW
FO
R
NOTE: DISTANCE FROM PARAPET WALL
TO BE DETERMINED BY LOCAL BUILDING
CODE REQUIREMENTS
OPTION 02: ROOF ACCESS
LADDER
OPTION 01: ROOF HATCH
(PREFERRED)
T
EXHAUST FAN, LOCATION PER
TENANT DRAWINGS
O
ARCHITECTURAL
CTURAL CANOPY
ECESSED
CESSED LED
LE C
WITH RECESSED
CAN
TING AND INTE
INTER
LIGHTING
INTERNAL ROOF
RAIN
N TO STORM SEWER
S
DRAIN
N
SAMPLE SINGLE TENANT
NT BUILD
BUILDI
BUILDING: ROOF AND HVAC PLAN
+/- 2,000 SF
NOTE: STRUCTURE SHOULD BE EN
ENG
ENGINEERED TO SUPPORT (2) 10 TON RTU’S MINIMUM.
PREFERRED MANUFACTURERS
- CARRIER
- TRANE
- LENNOX
5
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
TR
U
C
TI
O
N
26
SIGN - DT DIRECTIONAL
ILLUMINATED.
STARBUCKS
SPACE
+/- 2,000 SF
18
ENTRY PAVEMENT ARROW
(GREEN)(TYPICAL)
S
SIGN - DT DIRECTIONAL
ILLUMINATED.
FO
R
EXIT PAVEMENT ARROW
(WHITE)(TYPICAL)
C
O
N
SBUX
PATIO
NTS
ADJACENT TENANTS
15
N
O
T
SIGN - DT DIRECTIONAL
ILLUMINATED.
9
PYLON SIGN TO BE POSITIONED
ED
ON MOST VISIBLE CORNER TO
ATTRACH THE MOST TRAFFIC
FFIC
FIC
STARBUCKS MINIMUM PARKING
RECOMMENDATIONS:
- 18 STANDARD
- 2 ACCESSIBLE
- 20 TOTAL
SIGN - ILLUMINATED
MONUMENT DT EVOLVED;
EITHER PROPOSED LOCATION
SAMPLE END CAP/ MULTI-TENANT BUILDING: SITE PLAN REQUIREMENTS
+/- 2,000 SF
MACRO SITE PLAN EXAMPLE
SEE SPECS AND DETAILS FOR STARBUCKS BRANDED PAVEMENT GRAPHICS.
6
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
GREASE INTERCEPTOR
CONCRETE DT LANE STARTS 12'
BEFORE ORDER POINT CANOPY
A
STAR PATTERN AT DT
ORDER POINT
TIMER LOOP
12' - 0"
PEDESTRIAN
HAZARD STRIPING
5'-0"
MIN.
25' OUTSIDE RADIUS
MINIMUM
3'-0"
MIN.
20' INSIDE RADIUS
MINIMUM, 22'
PREFERRED
BOLLARD
ORDER POINT CANOPY WITH
DIGITAL ORDER SCREEN DT
EVOLVED. DO NOT LOCATE
ON CURVE. FINAL LOCATION
PER TENANT DRAWINGS.
5 PANEL MENU BOARD FREE
STANDING DT EVOLVED
STARBUCKS
SPACE
+/- 2,000 SF
12" MIN.
ADJACENT TENANTS
FO
R
CONCRETE DT LANE
ENDS 12' AFTER DT
BUMPOUT
PATIO - 250 TO 350 SF. SEE
WORKLETTER. PROVIDE (1) HOSE
BIBB AND (2) OUTLETS. LOCATE
PER TENANT DIRECTION
SIGN - DT DIRECTIONAL
ILLUMINATED. FINAL
LCOATION PER TENANT
DRAWINGS, TYP.
18" MIN.
A
N
PATIO RAILING,
O
T
EXIT ARROW AND
STRIPE (WHITE)
ENTRY
BIKE RACK,
ACK, MINIMUM 5'-0
5'-0" CLE
CLEAR
OF
F DOOR OR FURNITURE
W
WHEEL
STOP,
TYP.
18" MIN.
SAMPLE END CAP/ MULTI-TENANT BUILDING: SITE PLAN REQUIREMENTS
|
STARBUCKS COFFEE COMPANY
|
100’ (6 CAR STACK) MEASURED FROM C.L. OF DT
ORDER POINT TO C.L. DT BUMP OUT
+/- 2,000 SF
ENLARGED SITE PLAN EXAMPLE
SEE SPECS AND DETAILS FOR STARBUCKS BRANDED PAVEMENT GRAPHICS.
7
BOLLARD
C
TIMER LOOP
O
CONCRETE DT
LANE 12' WIDE
MINIMUM
CLEARANCE BAR FREE
STANDING DT EVOLVED
PRE-MENU BOARD
RD FREE
FRE
EVOLV
STANDING DT EVOLVED
N
SCREENING OF UTILITY
EQUIPMENT AS REQUIRED
PER TENANT DRAWINGS
LANDSCAPING BARRIER
BETWEEN DT LANE
AND BUILDING
ENTER PAVEMENT ARROW
AT DT ENTRANCE (GREEN)
(TYPICAL)
BOLLARD
BOLLARD
BOLLARD
S
TR
U
C
TI
O
N
20'-0" MIN.
TRASH AND RECYCLING ENCLOSURE.
DEDICATED OR EQUIVALENT 20' WIDE X
12' DEEP MINIMUM. SEE PAGE 11 FOR
MORE INFORMATION. PROVIDE
CONCRETE PAD AS SHOWN.
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
N
STORE FRONT
O
3/8" (10MM) METAL EDGE
OR SIMILAR FOR DESIGN
INTENT. SLIDE METAL
LEG UNDER MAT. CLIP
LEG EDGE AS NEEDED
TO FIT A CURVE.
STOREFRONT DOOR AND
THRESHOLD
CONCRETE FLOORING
C
1
17
WATERPROOF MEMBRANE,
(ONLY IF ON WOOD
SUBFLOOR)
TRANSITION - CONCRETE /WALKOFF MAT
Scale:
176
DIRECTION OF WINDOW
NDOW
SLIDE TO BE IN DIRECTION
OF CAR TRAVEL.
VEL.
U
1
TI
NEW WALK OFF MAT
DOMESTIC WATER LINE
C
O
N
S
TR
SANITARY LINE
GREASE LINE FOR
EXTERNAL GREASE
INTERCEPTOR.
10' - 1" MINIMUM
LL TO LL WALL
28'-0" MIN. CLEAR
ENGINE
EXPOSED DECK / STRUCTURE MINIMUM
UM
13'-0" AFF.MINIMUM WEB OPENING TO
ACCOMODATE DUCT WORK
VESTIBULE AS REQUIRED
D PER
TENANT PLANS
RECESSED WALK-OFF
FF
F MAT,
MAINTAIN 6" SETBACKS.
ACKS. SEE
DETAIL THIS SHEET.
EET.
DEMISING WALL,
LL, VARIES
PER LANDLORD
LORD
FO
R
STOREFRONT ENTRY,
LOCATION MAY VARY
400 AMP ELECTRICAL
PANELS, MINIMUM
QUANTITY (2) OR PER
WORK LETTER
INTERIOR PARTITION
WALLS TO ROOF DECK
THIRD ELECTRICAL
PANEL IF REQUIRED
3'-0" SECONDARY EGRESS
DOOR IF REQUIRED BY
LOCAL CODES
PROVIDE NATURAL COLOR CONCRETE.
GRIND AND SEAL WITH SHERWIN WILLIAMS
REXTHANE, 2 COATS WITH SHARK BITE
GRIP DURING 2ND COAT REQUIRED
N
O
T
BUILDING SHELL,
VARIES PER LANDLORD
3' - 6" DOOR
DEDICATED B.O.H.,
LOCATION MAY VARY
SAMPLE END CAP/ MULTI-TENANT BUILDING: FLOOR PLAN +/- 2,000 SF
8
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
N
O
TI
C
PLUMBING AND ELECTRICAL
STUB UPS AT FRONTBAR,
TYPICAL. FINAL QUANTITY
AND LOCATIONS TO BE PER
TENANT DRAWINGS
ENGINE
BUILDING SHELL, VARIES
PER LANDLORD
SANITARY LINE
C
O
N
S
TR
U
FLOOR SINK/DRAIN, TYPICAL.
FINAL QUANTITY AND
LOCATIONS TO BE PER
TENANT DRAWINGS
DOMESTIC WATER LINE
INTERIOR PARTITION
INTER
WA
WALLS TO ROOF DECK
FO
R
PROVIDE NATURAL COLOR CONCRETE.
AMS
MS
GRIND AND SEAL WITH SHERWIN WILLIAMS
REXTHANE, 2 COATS WITH SHARK BITE
TE
E
GRIP DURING 2ND COAT REQUIRED
GREASE LINE FOR
EXTERNAL GREASE
INTERCEPTOR
N
O
T
DEMISING WALL, VARIES
PER LANDLORD
SAMPLE END CAP/ MULTI-TENANT BUILDING: EXAMPLE UNDERGROUND PENETRATIONS
9
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
+/- 2,000 SF
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
N
= ZONES FOR ROOFTOP EQUIPMENT
O
TI
EXHAUST FAN, LOCATION PER
TENANT DRAWINGS
C
O
N
S
TR
U
C
4' - 0"
MINIMUM
REFER TO TENANT DRAWINGS FOR RTU SIZES AND LOCATIONS
ARCHITECTURAL CANOPY
WITH RECESSED LED CAN
LIGHTING AND INTERNAL ROOF
DRAIN TO STORM SEWER
ROOF PENETRATIONS TO MAINTAIN CLEARANCE
LEARANCE
EPARATE
EPARATES
FROM INTERIOR PARTITION THAT SEPARATES
HOU
FRONT OF HOUSE AND BACK OF HOUSE
EXPOSED DECK / STRUCTURE MINIMUM 13'-0" AFF.MINIMUM
M
WEB OPENING TO ACCOMODATE DUCT WORK
O
T
FO
R
ROOF PENETRATIONS TO MAINTAIN CLEARANCE
FROM INTERIOR CEILING FRAMING BELOW
N
NOTE:
DISTANCE FROM PARAPET WALL TO BE
DETERMINED BY LOCAL BUILDING CODE REQUIREMENTS
N
SAMPLE END CAP/ MULTI-TENANT
LTI-TENAN BUILDING: ROOF AND HVAC PLAN +/- 2,000 SF
NOTE: STRUCTURE SHOULD BE EN
ENG
ENGINEERED TO SUPPORT (2) 10 TON RTU’S MINIMUM.
PREFERRED MANUFACTURERS
- CARRIER
- TRANE
- LENNOX
10
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
4" WOOD SLAT
SEE SCHEDULE FOR
MORE INFORMATION.
COORDINATE TO MATCH BUILDING
ARCHITECTURE AND MATERIAL
4"X4" (120MMX120MM)
BLACK POW'ERCOATED
METAL POST WITH TOP
CLOSED, TYPICAL
4 1/2"
4" 1 1/2"
TYP. TYP.
6' - 6"
7' - 0" TALL MINIMUM
1 1/2" (25MM) GAP,
TYPICAL
3 - ELEVATION
REAR SCREEN AT SERVICE DOOR
EMPLOYEE GATE
1
NOTE: THE ARCHITECT AND/OR
ENGINEER OFRECORD ARE
REQUIRED TO DESIGN THE
STRUCTURE INCLUDING THE
CONCRETE SLAB ANDAPRON
TO COMPLY WITH CODE,
JURISDICTIONAL,AND TRUCK
SIZE REQUIREMENTS.
COORDINATE TO MATCH BUILDING
ARCHITECTURE AND MATERIAL
ENCLOSURE DOORS. DOORS
SHOULD SWING TO MINIMUM
115 DEGREES AND MAXIMUM
180 DEGREES.
2 - ELEVATION
3
RECYCLE
3 CUBIC YARDS
TRASH
4 CUBIC YARDS
12' - 0" DEEP MINIMUM
OPTION 02:
HOSE BIBB
COORDINATE TO MATCH
BUILDING ARCHITECTURE
AND MATERIAL
6" DIAMETER PIPE
BOLLARDS:,7+%/$&.
6/((9(
ENCLOSURE GATE,
CORRUGATED METAL
EMPLOYEE GATE
OPTION 01: HOSE BIBB
6" DIAMETER BOLLARD:,7+%/$&.6/((9(
COORDINATE TO MATCH BUILDING
ARCHITECTURE AND MATERIAL
2
PLAN
1 - ELEVATION
CANE BOLTS
20' - 0" WIDE MINIMUM
TRASH/ RECYCLING ENCLOSURE AND REAR SCREEN DETAILS
DEDICATED TRASH ENCLOSURE PREFERRED, IF SHARED, SPACE ALLOCATIONS STILL REQUIRED DEDICATED FOR STARBUCKS
11
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
10'-2"
DIGITAL ORDER SCREEN
WITH CANOPY
(BY STARBUCKS)
DOS CONTROL BOX
ON UNISTRUT FRAME
DIGITAL ORDER SCREEN
WITH CANOPY
(BY STARBUCKS)
EXPOSED CONCRETE
FOOTING
EXPOSED CONCRETE
FOOTING BY LL
11"
2"
FINISH GRADE
FINISHED DRIVE GRADE
CONCRETE FOOTING BY LL
2' - 6"
2' - 6"
2"
8-ANCHOR BOLTS:
1/2"Ø X 20"EMBED, A36
CONCRETE FOOTING BY LL
2'-11"W X 6'-0"L X 2'-6"D,
1-#4 REBAR MAT
CONCRETE FOOTING BY LL
2'-11"W X 6'-0"L X 2'-6"D,
1-#4 REBAR MAT
2' - 11"
BACK ELEVATION
CONCRETE CURB BY LL
CONCRETE CURB
BY LL
6' - 7"
LEFT ELEVATION
2' - 11"
FRONT ELEVATION
RIGHT ELEVATION
DTE - DIGITAL ORDER SCREEN WITH CANOPY
3'-0" x 3'-0" MIN. CLEAR AREA
FOR CONTROL BOX
1' - "
MIN. CLR. AREA
(3) CONDUIT FROM CONTROL BOX,
ROUTE TO DRIVE THRU WINDOW
(1) CONDUIT FROM CONTROL BOX,
ROUTE TO ELECTRICAL PANEL
3"
2'-6" DIA.
(/(9$7,21
PLAN
PLAN
3'-0"
NON-ILLUMINATED BOLLARD
CANOPY ABOVE
2. IF ABANDONING EXISTING FOOTING(S) IN
PLACE, CUT CONDUIT AND THREADED
BOLTS FLUSH TO TOP OF FOOTING.
5'-5"
FINISH
GRADE
30°
CONCRETE FOOTING BY
LL. SEE DETAIL 5/A-103
3' - 1"
2'-2"
(/(9$7,21
ELEVATION
MENU - 5 PANEL FREE STANDING
MENU - PLACEMENT
OUTLINE OF MENU
BOARD
10"
1'-0"
NOTES:
1. IF UTILIZING EXISTING FOOTING(S) FOR
SIGNAGE INSTALLATION, FASTEN TO
EXISTING THREADED BOLTS AND PROVIDE
CONDUIT AS NOTED. ENSURE BOLTS ARE IN
SOUND CONDITION.
5"
DETECTOR LOOP CENTERED ON DIGITAL ORDER SCREEN
2" (50MM) BELOW FINAL GRADE IN CONDUIT OR SAWCUT.
5'-5"
4'-0"
(1) CONDUIT TO CONTROL BOX
1'-5"
1' - 0"
MIN. CLR.
EDGE OF CONCRETE CURB
(1) CONDUIT ROUTE
BACK TO ELECTRICAL
PANEL BY LL.
0"
OUTLINE OF DIGITAL ORDER SCREEN
OF
ER
N
NT
EE
CE
CR
TO
RS
0"
E
'
RD
20
LO
ITA
DIG
3'
CONCRETE FOOTING 2'-6"W X 5'-6"L X 2'-6"D
(1) #4 REBAR MAT
4"
9"
36"MIN
9"
24" WIDE
4"
42" WIDE
9'-0"
OUTLINE OF MENU BOARD
PLAN
DTE - PRE-MENU 30 DEG
DRIVE-THRU EQUIPMENT DETAILS
COORDINATE SIZE AND LOCATION OF FOOTINGS WITH TENANT DRAWINGS
12
|
STARBUCKS COFFEE COMPANY
|
1" CONDUIT
FOR 120VAC
(CENTER IN
FOOTING) BY LL.
1' - 1"
3' - 1"
2' - 11"
1' - 11"
4' - 3"
4"X4"XW10XW10 WIRE
MESH REINFORCING
# 3 REBAR
BOTH WAYS
AS SHOWN.
CONCRETE FOOTING 3000#/sqin
2'-0"W X 3'-6"L X 3'-0"D (1) WIRE
MESH MAT 4" X 4" XW10XW10
OUTLINE OF DIGITAL
ORDER SCREEN
CONTROL BOX ON
CONCRETE FOOTING.
1' - 0"
(/(9$7,21
1" CONDUIT FOR
120VAC (CENTER IN
FOOTING) BY LL.
.
MIN. CLR. AREA
(1) CONDUIT, ROUTE TO CONTROL BOX
42" WIDE
1' - 1"
MENU BOTTOM
PLATE OUTLINE
9"
20°
FINISHED GRADE
PROPOSED BELOW GRADE
CONCRETE FOUNDATION.
5"
7' - 3 1/4"
3/4" DIA x 24" L ANCHOR BOLTS
(F1554 GRADE 36 - 4 EA.)
PRIMARY ELECTRICAL
INSIDE UL CONDUIT
TO MENU BOARD
#3 TIES (3 EA.)
3/4"DIA. X 24"LONG ANCHOR
RODS WITH 3/4"NUTS AND
FENDER WASHERS
#3 TIES TYP.
AT 4" O.C.
#5 VERTICALS (5 EA.)
3/4" DIA x 24" L ANCHOR BOLTS
(F1554 GRADE 36 - 4 EA.)
MENU BOTTOM
PLATE OUTLINE
4'-0"
4' - 0 1/4"
FREESTANDING MENU (DESIGN VARIES)
4"X4"XW10XW10 WIRE
MESH REINFORCING
FINISHED GRADE
NATURAL GRADE OR ENG FILL
2' - 6"
3' - 0" MIN. INTO
1 1/2"
FREESTANDING MENU
(DESIGN VARIES)
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
CURB BY LL.
C
B
A
12' - 0"
CONTROL BOX FASTENED
TO FRAME
1 1/2" SQ. UNISTRUT FRAME;
ANCHOR TO FTG.
CONDUIT WITH WATERTIGHT
COUPLING PER ELECTRICAL
2' - 0"
CONTROL BOX FASTEN
TO FRAME
6"
GRADE
MIN.
GRADE
FLEX CONDUIT
1' - 6" MAX.
6"
DOS BASE SHROUD
1 1/2" SQ. UNISTRUT
FRAME; ANCHOR TO FT
WATERTIGHT COUPLING
PER ELECT.
MIN.
CONDUIT WITH WATERTIGHT
COUPLING PER ELECTRICAL
2' - 0"
1' - 6" MAX.
FLEX CONDUIT
DIGITAL ORDER SCREEN BEYOND
2' - 0"
1' - 6" MAX.
6"
CANOPY BASE
SHROUD
DOS POST;
CLAMP UNISTRUT TO POST
AND BOLT DCB TO UNISTRUT
MIN.
ROUTE DOS POWER
WHIP THROUGH
MESH OPENING
FLEX CONDUIT
CANOPY MESH PANEL
GRADE
CONDUIT PER
ELECTRICAL
CONDUIT PER ELECTRICAL
POST FOOTING BEYOND
CONCRETE FOOTING
CONCRETE FOOTING
SECTION
SIDE ELEVATION
OPTION A
DTE - DOS CONTROL BOX AT CANOPY
(PREFERRED OPTION)
OPTION B
DTE - DOS CONTROL BOX (NO CANOPY
- ORDER SCREEN ONLY - TRADE DOWN)
FRONT ELEVATION
OPTION C
DTE - DOS CONTROL BOX (FREESTANDING
REMOTE - TRADE DOWN)
DRIVE-THRU EQUIPMENT DETAILS: SINGLE TENANT BUILDING
13
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
CONTROL BOX FASTENED
TO FRAME
1 1/2" SQ. UNISTRUT FRAME;
ANCHOR TO FTG.
CONDUIT WITH WATERTIGHT
COUPLING PER ELECTRICAL
SIGN - DT DIRECTIONAL
ILLUMINATED.
2' - 0"
FLEX CONDUIT
MIN.
CANOPY BASE
SHROUD
1' - 6" MAX.
ROUTE DOS POWER
WHIP THROUGH
MESH OPENING
6"
CANOPY MESH PANEL
D
C B A
GRADE
CONDUIT PER ELECTRICAL
CONCRETE FOOTING
SECTION
OPTION A
DTE - DOS CONTROL BOX AT CANOPY
(PREFERRED OPTION)
STARBUCKS
SPACE
+/- 2,000 SF
ADJACENT TENANTS
SBUX
PATIO
DOS POST;
CLAMP UNISTRUT TO POST
AND BOLT DCB TO UNISTRUT
DCB BOLTED TO FRAME
GRADE
1' - 6" MAX.
1 1/2" SQ. UNISTRUT FRAME;
ANCHOR TO WALL
1 1/2" SQ. UNISTRUT
FRAME; ANCHOR TO FT
CONDUIT WITH WATERTIGHT
COUPLING PER ELECTRICAL
UNISTRUT FRAME BRACED
TO GRADE PER MFGR.
WATERTIGHT COUPLING
PER ELECT.
GRADE
2' - 0"
MIN.
6"
6"
DOS BASE SHROUD
MIN.
CONDUIT WITH WATERTIGHT
COUPLING PER ELECTRICAL
2' - 0"
1' - 6" MAX.
FLEX CONDUIT
2' - 0"
DIGITAL ORDER SCREEN BEYOND
FLEX CONDUIT
CONTROL BOX FASTEN
TO FRAME
CONDUIT PER
ELECTRICAL
POST FOOTING BEYOND
FINISH GRADE
CONCRETE FOOTING
SIDE ELEVATION
FRONT ELEVATION
OPTION B
OPTION C
DTE - DOS CONTROL BOX (NO CANOPY - DTE - DOS CONTROL BOX (FREESTANDING
ORDER SCREEN ONLY - TRADE DOWN)
REMOTE - TRADE DOWN)
OPTION D
DTE - DOS CONTROL BOX WALL MOUNT
(TRADE DOWN FOR SPACE CONSTRAINED
DRIVE-THRU COMPONENT LAYOUT)
DRIVE-THRU EQUIPMENT DETAILS: END CAP DRIVE-THRU MULTI-TENANT BUILDING
14
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
7' - 11"
2 1/2" SQ. POST
3/4" SQ. PICKET
2' - 8 3/4"
3' - 0"
0' - 5"
1 7/16" x1 1/4"
FORERUNNER RAIL
CONCRETE FOOTING
3 15/16" SPACING TYP
BRACKET
ENTRY
PROVIDE (2) GFI OUTLETS AND (1) HOSE BIBB
AT 18" AFF, LOCATE PER TENANT DRAWINGS
DRIVE
THRU LANE
BIKE RACK
18" MIN.
18" MINIMUM CLEAR
FROM CURB
EXAMPLE PATIO RAILING PHOTOGRAPHS
PATIO RAILING
MANUFACTURER: AMERISTAR FENCE
STYLE: ECHELON PLUS 3/4 RAIL MAJESTIC PANEL
HEIGHT: 42”
FINISH: BLACK POWDER-COATED ALUMINUM
ALL LANDSCAPING TO MEET
LOCAL CODE AND COORDINATED
WITH TENANT.
ENLARGED PATIO PLAN
15
|
STARBUCKS COFFEE COMPANY
PATIO RAILING
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
INCORRECT
LANDSCAPE EXAMPLES
16
|
STARBUCKS COFFEE COMPANY
CORRECT
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
NOTE: DECOMARK THERMOPLASTIC FOR
STAR PATTERN AND WAYFINDING GRAPHIC
ARROW IS A LONG LEAD TIME ITEM.
3
4
r r
12' - 0"
r
1b
r r
1d
2
2
7+(5023/$67,&$33/,('
*5$3+,&21/<$9$,/$%/(
7+528*+67$5%8&.6
63(&,),('9(1'25
2
1c
3
DTE - WAYFINDING GRAPHIC STAR
PATTERN - HORIZONTAL
1a
),1,6+*5$'(
5”X5” BLACK STEEL POST
2 BANDS OF 1” WHITE REFLECTIVE TAPE.
WB`/3W(r
n
r
"drV0(T`3Fr`3?A3 CVr
Q FWMF(r$r,T((Fr
"crV/(T`3Fr`3??3 BVr
4
>r
r L
4
DTE - NON-ILLUMINATED
BOLLARD - AXON
&21&5(7()227,1*
DTE - NON-ILLUMINATED
BOLLARD - DETAIL
Q FWMF(r$r,T((Fr
"crV/(T`3Fr`3??3 BVr
MRW4MF ?r
V( Br
mr
2 DTE - WAYFINDING
GRAPHIC ARROW - EXIT
MQW3MG ?rV( Br or
2 DTE - WAYFINDING
GRAPHIC ARROW - DOUBLE
2 DTE - WAYFINDING
GRAPHIC ARROW - SINGLE
2' - 1 1/4"
CUSTOMER ELEVATION
1a
2' - 1 1/4"
2' - 7"
2' - 2"
1' - 0"
SIGN WITH BASE
AND PLATE COVER
(BY STARBUCKS)
3' - 10"
SIGN WITH BASE
AND PLATE COVER
(BY STARBUCKS)
3' - 10"
SIGN WITH BASE
AND PLATE COVER
(BY STARBUCKS)
3' - 10"
6' - 0"
2' - 0"
BACKSIDE ELEVATION
SIGN WITH BASE
AND PLATE COVER
(BY STARBUCKS)
FINISH GRADE
FINISH GRADE
FINISH GRADE
FINISH GRADE
CONCRETE FOOTING 24"
DIAMETER X 30" DEEP
WITH (1) 1" CONDUIT
WITH PULLSTRING TO 4"
ABOVE GRADE
CENTERED IN FOOTING
CONCRETE FOOTING 18"
DIAMETER X 24" DEEP
WITH (1) 1" CONDUIT
WITH PULLSTRING TO 4"
ABOVE GRADE
CENTERED IN FOOTING
CONCRETE FOOTING 18"
DIAMETER X 24" DEEP WITH (1)
1" CONDUIT WITH PULLSTRING
TO 4" ABOVE GRADE
CENTERED IN FOOTING
CONCRETE FOOTING 18"
DIAMETER X 24" DEEP WITH (1)
1" CONDUIT WITH PULLSTRING
TO 4" ABOVE GRADE
CENTERED IN FOOTING
DTE- MONUMENT SIGN SIGN 1b
DTE - DIRECTIONAL SIGN
1c
FINISH GRADE
DTE - DIRECTIONAL SIGN - ENTRY
CONCRETE FOOTING 30"
DIAMETER X 60" DEEP
SITE SIGNAGE AND PAVEMENT GRAPHIC DETAILS
17
|
STARBUCKS COFFEE COMPANY
|
SIGN WITH BASE AND PLATE
COVER (BY STARBUCKS)
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
1d
|
CHICAGO DESIGN STUDIO
|
DTE - CLEARANCE BAR
17 JANUARY 2017
ALIGN
STAINLESS STEEL
ANGLE TO CAP
INTERIOR WALL.
HEM BOTTOM EDGE
1' - 6"
PLAN
WINDOW PER PLAN
CONCRETE CURB
2"
CANOPY ABOVE WITH RECESSED LED
CAN LIGHTING. 4'-0" DEEP MINIMUM
1 3/4"
BUMP-OUT
CENTERLINE
DETECTOR LOOP CENTERED ON
WINDOW 2" (50 MM) BELOW
FINISHED GRADE. ROUTE (1)
CONDUIT TO DRIVE THRU WINDOW
AND TERMINATE NEAR TIMER SIGNAL
PROCESSOR (TSP)
12" MINIMUM
---------14" MAXIMUM
CONCRETE INFILL AT
WINDOW BUMP-OUT
ADDITIONAL FURRING
BY STARBUCKS
5' - 8"
5' - 8"
5'-0" MIN. CLR.
2' - 2 1/2"
6"
3' - 11 1/2"
STAINLESS STEEL
SHELF
BOLLARD
SIDE WINDOW
PER PLAN
3
DRIVE THRU SHELF
10'-1" MIN.
CLEAR
4' - 0"
ARCHITECTURAL CANOPY WITH
RECESSED LED CAN LIGHTING
AND INTERNAL ROOF DRAIN TO
STORM SEWER
MINIMUM
AIR CURTAIN
ARCHITECTURAL CANOPY WITH
RECESSED LED CAN LIGHTING
SINGLE PANEL DRIVE-THRU WINDOW
ASSEMBLY PER PLAN. COLOR: DARK
BRONZE OR CLEAR ALUMINUM
9' - 6" MINIMUM
9' - 6" MINIMUM
AIR CURTAIN
SCONCE LIGHT
PER STARBUCKS
SPECIFICATIONS
WINDOW PER PLAN
ATTACH SHELF TO BUILDING
EXTERIOR FLUSH TO TOP OF ROUGH
OPENING, CENTERED ON WINDOW
EXISTING OR NEW
EXTERIOR WALL SYSTEM
12" MINIMUM
------------------------14" MAXIMUM
ELEVATION
1
HOLD
3' - 6"
EXTERIOR FINISH GRADE
+/- 2"
3' - 6"
3' - 0"
INTERIOR FINISH GRADE
3' - 0" AFF
BOLLARD
DTE - DRIVE THRU WINDOW BUMP-OUT
2
DRIVE THRU WINDOW
BUILDING DRIVE-THRU BUMP OUT DETAILS
18
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
AA300 - 275 PASS-THRU AIR CURTAIN SYSTEM
FINISH TO MATCH STOREFRONT
GLAZING SYSTEM
THE ACCESS AIR 300
PASS-THRU AIR CURTAIN
SYSTEM™
4-1/2" REF.
(114 mm)
47-3/4"
(1213 mm)
ROUGH OPENING
7-3/8"
(187 mm)
9-7/8"
(251 mm)
16" (406 mm)
16-1/4"
(413 mm)
ROUGH OPENING
For use with the 275 Single Panel Window
72" (1829 mm)
MIN. DISTANCE FROM
FLOOR TO BOTTOM
OF UNIT.
The Ready Access AA300 Pass-Thru Air Curtain
System is designed to be an integral part of your drivethru operation by providing comfort for both operator
and customer during the coldest of days as well as
satisfying health department codes for fly fan
application.
Quality Construction
The exterior housing of the AA300 Air Curtain System is
manufactured using bronze or clear anodized aluminum.
47-1/2"
21-3/4"
(1207 mm)
Features and Benefits
Satisfies heath department requirements for "Fly Fan"
applications while it reduces and deflects the amount
of outside wind blowing into the building. This also
reduces heating and air-conditioning loss as well as
reducing unwanted environment factors such as dust
and exhaust fumes from entering the building. Acts as
a fly fan to deter insects from entering the building
during warm weather conditions.
Provides the owner/operator with a stable, comfortable
working environment for all crew members. Reduces
Drive-Thru operation expenses by diminishing
employee turnover.
Unique Design
The AA300 Air Curtain System is the only system on the
market today that offers an outside and inside heated air
flow. It is designed for use with any flushmount window.
(553 mm)
Fully Assembled, Ready to Install
The Access Air 300 system is shipped completely preassembled and ready for installation, lowering
installation costs. Normal installation for new store
construction takes less than two hours.
10" (254 mm)
6" (152 mm)
UNIT SPECIFICATIONS:
208/240 VOLTS
7100 HEATER WATTS
32 ACTUAL UNIT AMPS
1 (SINGLE) PHASE
60 HZ
600 FPM AIR VELOCITY
13-7/8"
(352 mm)
Warranty and Service Support
Your Access Air 300 System comes with a one year
limited warranty on parts and labor. In addition, each
Pass-Thru Air Curtain System is backed by a worldwide
service organization.
AVAILABLE OPTIONS
Power coat painting is available upon request for a wide
range of custom colors.
1815 Arthur Drive, West Chicago, Illinois 60185 - Direct (630) 876-7766 - Toll Free (800) 621-5045 - Fax (630) 876-7767
E-mail: [email protected] - Web site: www.ready-access.com - Members: CSI, NRA, NAFEM, CFESA
1815 Arthur Drive, West Chicago, Illinois 60185 - Direct (630) 876-7766 - Toll Free (800) 621-5045 - Fax (630) 876-7767
E-mail: [email protected] - Web site: www.ready-access.com - Members: CSI, NRA, NAFEM, CFESA
DRIVE-THRU WINDOW SPECIFICATION - PREFERRED
19
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
022502-A300275
Modes of Operation
The Ready Access AA300 Pass-thru Air Curtain
System is versatile in function and design, offering
operators four separate modes of operation.
* Outside warm air flow only
* Inside warm air flow only
* Both outside and inside warm air flow
* Outside fly fan operation only
275 SERIES
275 SINGLE PANEL SLIDER SERIES
FINISH TO MATCH STOREFRONT
GLAZING SYSTEM
275 - 47-1/2"W x 43-1/2"H
"W" ROUGH OPENING
Glazing Rough Opening =
47-3/4"W (1213 mm) x 43-3/4"H (1111 mm)
Masonry Rough Opening =
48"W (1219 mm) x 44"H (1118 mm)
For retail operators who want to get an edge on their
competition by offering customers convenient, face-to-face
service, the 275 Single Panel Slider is perfect. Ideal for fast
food, walk-up service, and many other applications.
275 - 47-1/2"W x 35-3/4"H
Glazing Rough Opening =
47-3/4"W (1213 mm) x 36"H (914 mm)
Masonry Rough Opening =
48"W (1219 mm) x 36-1/4"H (921 mm)
PRODUCT DESCRIPTIONS
4 Standard Sizes Available
- 47 1/2"W x 43 1/2"H with a 19" wide x 36" high service opening
- 47 1/2"W x 35 3/4"H with a 19" wide x 28" high service opening
- 47 1/2"W x 35 3/4"H with a 15" wide x 28" high service opening
- 35 3/4"W x 35 3/4"H with a 14" wide x 28" high service
opening (SC / MOER)
- Passes California restricted opening requirements of 432
square inches.
3 Modes of Operation
- 275 Manual Open/Self Closing
So simple to operate, the service door opens effortlessly and
automatically slides shut when operator releases the handle.
- 275 M.O.E.R. (Manual Open/Electronic Release)
The 275 Manual Open/Electronic Release Window has a manual
open, self closing operation which electro-magnetically holds the
window open until the operator finishes their transaction and
steps out of the presence sensor. This unit is field adjustable to
the length of time the window will stay open.
- 275 Electric
With a hands-free operation the 275 Electric Window is ideal for
heavy traffic situations. It provides easier operation and speedier
service than the manual operating windows. This unit is field
adjustable to the length of time the window will stay open.
Quality Construction
Anodized aluminum extrusions, stainless steel and 1/4"
tempered glass combine to give you an attractive window that
not only enhances building exteriors, it will not rust, pit or
weather. Track free bottom sill provides for a contaminant free
surface.
"H" ROUGH OPENING
275 - 35-3/4"W x 35-3/4"H
Fully Assembled, Ready to Install
Ready Access windows are shipped completely preassembled,
and fully glazed for lower installation costs. Normal installation
takes less than two hours.
Glazing Rough Opening =
36"W (914 mm) x 36"H (914 mm)
Masonry Rough Opening =
36-1/4"W (921 mm) x 36-1/4"W (921 mm)
Unique Design
Bottom sill is angled downward to provide protection against
the elements such as rain, sleet, and snow.
FOR FULLY AUTOMATIC ELECTRIC UNIT
POWER HOOK-UP
INSIDE OF HEADER
47-1/2"
Warranty and Service Support
Your Ready Access window comes with a one year limited
warranty on parts and labor. Each window is backed by a
worldwide service organization.
(1207 mm)
36"
(914 mm)
MIN. DISTANCE
FROM TOP OF
SILL TO FLOOR
4"
(102 mm)
PRESENCE
SENSOR
43-1/2"
(1105 mm)
STANDARD OPTIONS
The 275 series window is available in statuary bronze,
or clear anodized aluminum.
A retrofit kit is available for the 275 Self Closer that easily
upgrades the window from a manual operation to a MOER or
fully automatic electric operation.
19" X 36"
SERVICE OPENING
BOTH SIDE FRAMES ARE HOLLOW
FOR ELECTRICAL ACCESS FROM EACH
CORNER LEADING TO THE HEADER.
ELECTRICAL REQUIREMENTS
Right to left or left to right opening available (as seen from
outside view).
For non food service applications window can be made
manual open / manual close.
USA (DOMESTIC) : 115 vac - 60 Htz WITH A 15 amp BRANCH CIRCUIT
INTERNATIONAL : 220/240 vac - 50/60 Htz WITH A MAX.
8 amp BRANCH CIRCUIT
TWO STANDARD WINDOW HEIGHTS
CUSTOM OPTIONS
43-1/2" H WITH 19"W x 36"H SERVICE
Custom sizes are available to satisfy any unusual operations
requirement or health department code.
Tinted glass is available upon request.
Powder coat painting is available in a wide range of custom
colors.
1815 Arthur Drive, West Chicago, Illinois 60185 - Direct (630) 876-7766 - Toll Free (800) 621-5045 - Fax (630) 876-7767
E-mail: [email protected] - Web site: www.ready-access.com - Members: CSI, NRA, FEDA, NAFEM, CRA
35-3/4" H WITH 19"W x 28"H + 15"W x 28"H SERVICE
1815 Arthur Drive, West Chicago, Illinois 60185 - Direct (630) 876-7766 - Toll Free (800) 621-5045 - Fax (630) 876-7767
E-mail: [email protected] - Web site: www.ready-access.com - Members: CSI, NRA, NAFEM, CFESA
DRIVE-THRU WINDOW SPECIFICATION - TRADE DOWN
20
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
022502-275
Triple Security Locks
The 275 automaticaly locks each time the window closes,
providing security when the window is left unattended. When
the drive-thru is closed, thumbturn & night security bar helps
prevent outside entry. In high risk locations, an optional security
bar set is available.
302 STAINLESS STEEL
DRIVE-THRU WINDOW SHELF CUT SHEET
21
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
B
A
PYLON SIGN
C
DRIVE THRU DIRECTIONAL
SIGNAGE
D
DRIVE THRU DIRECTIONAL
WAYFINDING SIGNAGE
CLEARANCE BAR: NON-ILLUMINATED
E
DRIVE THRU MONUMENT
SIGNAGE (CAN BE MODIFIED)
EXAMPLE ILLUMINATED BRAND SIGNAGE
22
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
ISOMETRIC VIEW
ALUMINUM RETAINER
WITH 1" RETURN
PAINTED BLACK
4 1/2"
3 1/4"
ALUMINUM FILLER
PAINTED BLACK
COPY AND CHEVRONS
BACKED UP WITH WHITE
POLYCARBONATE
4 1/2"
1"
1 1/2"
1' - 0"
6' - 0"
3' - 1"
WHITE POLYCARBONATE WITH
FIRST SURFACE VINYL
FILM
1' - 8 1/2"
ALUMINUM COVER
PAINTED BLACK
MASONRY BASE TO
MATCH BUILDING
FINISH GRADE
ELEVATION
6 3/4"
1' - 4"
ANCHOR BOLTS AND
BASE PLATE
MASONRY BASE BELOW
TO MATCH BUILDING
EQ
3' - 1"
EQ
ALUMINUM COVER
PAINTED BLACK
6' - 0"
PLAN
EXAMPLE BRAND SIGNAGE - MONUMENT SIGN PANEL
NOTE: LAYOUTS AND PROPORTIONS ARE FOR DESIGN INTENT ONLY.
23
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
B
C
A
EVOLVE LOGO DISK FLUSH MOUNTED
D
DRIVE THRU CABINET FLUSH MOUNTED.
INLINE WORDMARK FLUSH MOUNTED (COLOR SELECTION
DEPENDS ON BUILDING MATERIALITY)
STACKED WORDMARK FLUSH MOUNTED (COLOR
SELECTION DEPENDS ON BUILDING MATERIALITY)
EXAMPLE ILLUMINATED BRAND SIGNAGE - BUILDING SIGNAGE
24
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
FABRIC AWNING SPECIFICATION:
BLACK - SUNBRELLA BLACK #4608
1
1
FABRIC AWNING DETAIL:
SOLAR SCREEN DETAIL:
2
32
°
5' - 0"
4' - 0"
4" CHANNEL STEELl
1' - 10"
FRAME MOUNTING BRACKET
SPACED EVERY 2'-0" TOP.
1' - 0"
USE 2 ANCHOR
BOLTS PER
FRAME
MOUNTING
BRACKET.
SUNBRELLA "%/$&." #
)ABRIC AT SLOPED AND
VERTICAL FRONT
3$1(/6$1'END
STEEL SLATS
2' - 0"
FABRIC PANEL
3' - 0"
TEK SCREW
1" (25MM) SQUARE
EXTRUDED ALUMINUM
TUBE FRAME
SUPPORT STRUT
ATTACH TO WALL PER
STRUCTURAL DRAWINGS.
PROVIDE FLASHING AND SEALANT
AT STRUCTURAL CONNECTIONS
USE 2 ANCHOR
BOLTS PER
FRAME
MOUNTING
BRACKET.
6"
TEK SCREW
FRAME MOUNTING
BRACKET SPACED EVERY
2'-0" TOP.
NOTE: AWNING VENDOR TO FIELD VERIFY AWINING DIMENSIONS AND CONFIRM DESIGN WITH
STARBUCKS DM PRIOR TO CONSTRUCTION
3
ARCHITECTURAL METAL CANOPY DETAILS:
INTERIOR FINISH
METAL FLASHING
1" DIA. TIE ROD W/ CLEVIS.
FINISH TO BE DETERMINED
WHITE THERMOPLASTIC
ROOFING SYSTEM
PL STEEL; FINISH TO BE
DETERMINED
METAL FLASHING
MTL FLASHING; FINISH TO BE
DETERMINED
WOOD BLOCKING
4" ROOF INSULATION
MINIMUM 1:12 SLOPE
TOWARD DRAIN
WOOD BLOCKING
ROOF MEMBRANE LAYER
ROOF INSULATION
1" GAGE ROOF DECKING
5X5X3/8" PLATE EA. SIDE OF
WALL W/ (4) - 1/2" DIA. THRU
BOLTS AT 3" SPACING & GAGE
5X5X3/8" PLATE
1" GAGE ROOF
DECKING
3/8" PLATE
1" DIA. TIE-ROD W/ CLEVIS
1' - 0"
PLATE
BLACK COMPOSITE
RECESSED LED CAN
CENTERED IN CANOPY
TUBE STEEL
'L' ANGLE
WELD PLATE TO TUBE
STEEL
ROOF SOFFIT
'C' CHANNEL; FINISH
TO BE DETERMINED
AWNING AND CANOPY DETAILS: DESIGN INTENT ONLY
25
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
3
2
1
3
3
3
3
2
2
EXAMPLE OF POSSIBLE SIGNAGE LOCATIONS
26
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
3
EXAMPLE STORES
27
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
SKU 226014
TAG
SKU
M335
Rack, Bike Black Hoop
MODEL:
HR-FT-EPX Black
226014
TAG
M335
Rack, Bike Black Hoop
Page 2 of 6
MANUFACTURER:
Dero Bike Racks
BIKE RACK CUT SHEET
EQUIVALENT SUBSTITUTIONS PERMITTED. PROVIDE SUBSTITUTED SPEC. TO STARBUCKS FOR REVIEW AND APPROVAL.
28
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
VDL100
Vehicle Detector Loop
INSTALLATION INSTRUCTIONS
The following instructions are for installation of the HME VDL100 Vehicle Detector Loop in a single
drive-thru traffic lane, for vehicle detector use with any HME drive-thru communication system.
The loop should be installed prior to pouring concrete for paving the lane, and therefore requires
coordination with the paving contractor. Pay careful attention to the illustrations on the back of this
page, especially regarding loop dimensions and the depth and position of its installation.
A loop must always be installed at the speaker post or menu board. If you received two loops, the
second loop should typically be installed at the service window. If you received three loops, the third
loop should typically be installed at the cashier window. Locations of the second and third loops may
vary depending on specific requirements.
NOTE:
In some cases the distance from the loop to where the conduit exits the ground into the
speaker post cabinet may exceed three feet. In such cases, an additional ½ inch (12.7 mm) PVC pipe
will be required (not provided).
LOOP AREA PREPARATION (Refer to Figure 1)
x The loop should begin 12 to 18 inches (305 – 457 mm) out from the curb.
x The forward edge of the loop should be lined up with the midpoint of the menu board, speaker
post or drive-thru window.
x A 3 foot (914 mm) perimeter, free from rebar, wire screen, reinforcing bars, electrical cable or metal
objects should be provided. Any metal nearby disturbs the loop’s magnetic field, thus reducing the
field in which detection takes place. Electrical cables near the loop can possibly cause false impulses
to the magnetic field generated by the loop, causing erratic operation of the detector.
TOOLS/MATERIALS REQUIRED
Shovel; hacksaw; tape measure; wood supports; securing wire; PVC adhesive & brush
Figure 1. Loop area preparation
Figure 2. Loop layout and connections
NOTE: PVC adhesive (not provided) must be applied wherever PVC couplings and pipe are fitted together.
x Flatten the loop (folded for shipping) as shown in Figure 2 (1). Fit the pipe securely into the couplings (2).
Lay the loop flat in the drive-thru lane and position it as shown in Figure 2. Elevate the loop on supports
that are anchored to the ground, as shown in Figure 3. Level the loop so it will be 2 inches (51 mm) or less
from the paved surface when the concrete is poured. Fasten the loop to the supports with wire, so it will not
float when the concrete is poured.
x Pull the loop wires through the sleeve coupling (3) and the PVC loop extension (4). Slide one end of the
sleeve coupling (3) over the nipple on the corner fitting of the loop (5), and slide the end of the loop
extension (4) into the other end of the sleeve coupling (3).
x Pull the loop wires through the elbow coupling (6) and the remaining 2 foot (.61 meter) piece of PVC (7).
Slide the two ends (of 4 & 7) into the coupling (6), positioning the piece of PVC (7) so it points upward, out
of the ground. Be certain it is next to and parallel to the outlets of the conduit coming into the speaker
post or menu board from the building.
PARTS LIST
x Prefab (folded) loop, 1.5 feet (.46 meter) x 5 feet (1.52 meter)
1 ea
x Coupling for ½ inch (12.7 mm) PVC tubing
1 ea
x 90 degree elbow for ½ inch (12.7 mm) PVC tubing
1 ea
x ½ inch (12.7 mm) PVC tubing, 2 feet (.61 meter) long
1 ea
x ½ inch (12.7 mm) PVC tubing, 3 feet (.91 meter) long
1 ea
Figure 3. Side view of loop in asphalt or concrete
PROCEDURE
x Check the contents of this package against the parts list. If any item is missing, contact your
HME sales representative.
x Remove the elbow coupling, Figure 2 (6), from the cable. The cable was threaded through the
coupling for shipping only.
x Assemble the loop as instructed on the back of this page.
x Measure the distance from the curb to the outlet of the conduit that comes from the building into the
speaker post or menu board to determine if the enclosed 3 foot (.91 meter) PVC loop extension reaches
from the loop to the conduit as shown in Figure 2 (4). If it does, proceed to the next paragraph. If not,
substitute a longer piece of ½ inch (12.7 mm) PVC pipe (not provided). Measure and cut the pipe to reach
from the loop to the point where it must exit the ground into the speaker post.
Waste Electrical and Electronic Equipment (WEEE)
The European Union (EU) WEEE Directive (2002/96/EC) places an obligation on producers (manufacturers, distributors and/or retailers) to
take-back electronic products at the end of their useful life. The WEEE Directive covers most HME products being sold into the EU as of
August 13, 2005. Manufacturers, distributors and retailers are obliged to finance the costs of recovery from municipal collection points, reuse,
and recycling of specified percentages per the WEEE requirements.
Instructions for Disposal of WEEE by Users in the European Union
The symbol shown below is on the product or on its packaging which indicates that this product was put on the market after August 13, 2005
and must not be disposed of with other waste. Instead, it is the user’s responsibility to dispose of the user’s waste equipment by handing it over
to a designated collection point for the recycling of WEEE. The separate collection and recycling of waste equipment at the time of disposal will
help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information
about where you can drop off your waste equipment for recycling, please contact your local authority, your household waste disposal service or the
seller from whom you purchased the product.
VEHICLE DETECTOR LOOP CUT SHEET - OPTION 1 (POUR IN PLACE)
29
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
Saw-Cut Vehicle Detector Loop
INSTALLATION INSTRUCTIONS
These instructions are for saw-cut loop installation in an existing concrete or asphalt drive-thru
traffic lane, for use with HME’s Drive-Thru Audio or Timer Systems. Refer to the illustrations on
the back of this page. Note the differences in loop location for audio systems and timer systems.
Failure to follow these instructions in saw-cut vehicle detector loop installation may cause your
HME Drive-Thru Audio System or Timer System warranty to be voided.
TOOLS/MATERIALS REQUIRED
x Drill with ¾ inch (19 mm) drill bit (optional)
x Type #20 AWG XLPE cable, 100 feet (30.5 meters)
x Concrete and mortar-repair sealant
(Quikrete Hydraulic Water-Stop Cement or equivalent)
CAUTION: Hard setting epoxies should never be used.
Figure 1. Saw-cut loop locations
x S/G foam tubing, 3 feet
(.91 meter)
x Concrete-cutting saw
x Marking chalk
PROCEDURE
Carefully examine the illustrations on the back of this page before proceeding.
x Lay out and mark with chalk, the exact size and location of the slot before cutting it. The rectangular
slot should begin 12 – 18 inches (305 – 457 mm) out from the curb, with its forward edge even with
the midpoint of the menu board, speaker post (Location 1) or drive-thru window (Location 2). Its
dimensions should be 5 feet (1.52 meters) across the drive-thru lane, and 18 inches (457 mm) wide.
CAUTION: If the loop is being installed in an existing cut, or over an existing loop that is being
deactivated, cut through the old loop in 5 or 6 places so it will not interfere with the new
loop. Also, if there is a control joint in the concrete, the loop should not span it.
x BE AWARE: A 3 foot (.91 meter) perimeter, free from rebar, wire screen, reinforcing bars, electrical
cables or other metal objects should be provided around and under the loop area. Any metal within
this perimeter disturbs the loop’s magnetic field, thus reducing the field in which detection takes place.
x Cut the slot ¼ inch (6.25 mm) wide, and 1½ – 2¼ inches (38 – 52 mm) deep, along the chalk lines to
form a basic rectangular loop. Make an additional 45º angle cut at each of the four corners of the
rectangle, to prevent sharp, 90º angles of the concrete from damaging the loop-wire insulation. (If 45º
angles are not cut, a ¾ inch [19 mm] hole must be drilled at each corner.) Also cut a lead-wire slot,
¼ inch (6.25 mm) wide and 1 inch (25 mm) deep, from one corner of the rectangular loop cut to a
point nearest the conduit through which the cable is routed into the store.
x Clean the slot thoroughly with compressed air, and allow the slot and the area around it to dry
completely. Be sure no moisture or sand gets back into the slot while the loop is being installed.
x Allowing sufficient lead wire to be routed from the speaker post or menu board into the store, to the
audio system base station or timer control unit, lay the first turn of wire in the slot in a clockwise
direction, routing it through the 45º angle cuts at each corner.
CAUTION: A continuous piece of unspliced wire must be used. Avoid damaging the insulation
on the wire. Nicks or abrasions can permit moisture to enter the loop, making it inoperable.
x Gently press the wire down to the bottom of the slot, all the way around the loop, with a blunt wooden
stick. Do not use a metal instrument or tool. Lay six turns of wire in the slot. After the last turn, lay
3 inch (76 mm) lengths of foam tubing, evenly spaced, on top of the wire to hold it in place in the slot.
x Fill the slot completely with sealant, covering the wire completely so it is not visible.
x Cut the remaining wire to equal the length of the lead wire, twist the two wire ends together to form
a twisted pair, with five turns per foot. This twisted pair should go into the lead-wire cut.
x Before applying the sealant, test the loop for insulation resistance and DC continuity resistance.
If the DC resistance is greater than 3 ohms, or the insulation resistance to ground is less than 100
megohms, the wire is damaged and the entire loop must be replaced.
x Apply the sealant.
x Solder and insulate all connections to lead wires.
Figure 2. Saw-cut loop parameters
Figure 3. Saw-cut loop side view
Waste Electrical and Electronic Equipment (WEEE)
The European Union (EU) WEEE Directive (2002/96/EC) places an obligation on producers (manufacturers, distributors and/or
retailers) to take-back electronic products at the end of their useful life. The WEEE Directive covers most HME products being sold
into the EU as of August 13, 2005. Manufacturers, distributors and retailers are obliged to finance the costs of recovery from
municipal collection points, reuse, and recycling of specified percentages per the WEEE requirements.
Instructions for Disposal of WEEE by Users in the European Union
The symbol shown below is on the product or on its packaging which indicates that this product was put on the market after August
13, 2005 and must not be disposed of with other waste. Instead, it is the user’s responsibility to dispose of the user’s waste equipment
by handing it over to a designated collection point for the recycling of WEEE. The separate collection and recycling of waste
equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human
health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact
your local authority, your household waste disposal service or the seller from whom you purchased the product.
VEHICLE DETECTOR LOOP CUT SHEET - OPTION 2 (SAW-CUT)
30
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
17 JANUARY 2017
Door Hardware Set #1, Service Door, Exterior (42" wide door)
No. Item
Description
3 Hanging Devises
FBB191 Door Hinge 5 x 4.5 NRP
1 Securing Devices
C607 7-pin Core Combinated 'A' keyway
I/O 2000L-03IC Auto Locking Door Alarm, IC;
No CTR includes Mortise Cylinder
1 Securing Devices
1 Closing Devices
8900 Door Closer 8916 AF89P
1 Protective Trim Units K1050 B4E Kickplate 10x40
1 Accessories
16A Rain Drip 46"
1 Accessories
137NA Weather Strip 17.5' 42x84
1 Accessories
C607 Door Sweep 42"
1 Miscellaneous Items LN2068 Door Spy
1 Stop
480H Door Stop
1 Threshold
325 Half Saddle Threshold
Door Hardwre Set #2, Service Door, Secondary Exterior
No. Item
Description
3 Hanging Device
FBB191 Door Hinge 4.5 x 4.5 NRP
1 Securing Device
C607 7-pin Core Combinated 'A' keyway
I/O 2000L-03IC Auto Locking Door Alarm, IC;
No CTR includes Mortise Cylinder
1 Securing Device
1 Closing Device
8900 Door Closer 8916 AF89P
1 Protective Trim Units K1050 B4E Kickplate 10x34
16A Rain Drip 40"
1 Accessories
1 Accessories
137NA Weather Strip 17' 36x84
1 Accessories
C607 Door Sweep 36"
1 Miscellaneous Items LN2068 Door Spy
1 Stops
480H Door Stop
1 Threshold
325 Half Saddle Threshold
Manufacturer Finish
Stanley Hardware 630
Falcon Lock
626
Sur-lock
Dorma
Rockwood
National Guard
National Guard
National Guard
Locknet
Rockwood
National Guard
-689
630
A
A
A
Silver
Satin Nickel
--
Manufacturer Finish
Stanley Hardware 630
Falcon Lock
626
Sur-lock
Dorma
Rockwood
National Guard
National Guard
National Guard
Locknet
Rockwood
National Guard
-689
630
A
A
A
Silver
Satin Nickel
--
Door Hardware Set #3, Service Door, Interior to Building Corridor
No. Item
Description
Manufacturer
3 Hanging Devises
FBB179 Door Hinge 4.5 x 4.5 NRP
Stanley Hardware
1 Securing Devices
C607 7-pin Core Combinated 'A' keyway
Falcon Lock
I/O 2000L-03IC Auto Locking Door Alarm,
IC; No CTR includes Mortise Cylinder
1 Securing Devices
Sur-lock
1 Closing Devices
8900 Door Closer 8916 AF89P
Dorma
1 Protective Trim Units K1050 B4E Kickplate 10x2" LDW
Rockwood
1 Miscellaneous Items LN2068 Door Spy
Locknet
1 Stop
480H Door Stop
Rockwood
Door Hardware Set #4, Entry Door, Exterior (Kawneer TriFab)
No. Item
Description
3 Hanging Devices
4.5 Butt Hinge NRP
1 Securing Devices
MS1850S, Deadbolt
1
1
1
1
1
Securing Devices
Securing Devices
Closing Devices
Door Pull
Stop
KSP 307-601
Interchangable Core C647A
LCN 4041
#108
#473
|
STARBUCKS COFFEE COMPANY
|
MIDWEST/MID-AMERICA LANDLORD DESIGN INTENT
|
CHICAGO DESIGN STUDIO
|
-689
630
Silver
Satin Nickel
Manufacturer Finish
Stanley Hardware 626
Adams Rite
628
Adams Rite
Falcon
LCN
Rockwood
Rockwood
DOOR HARDWARE
31
Finish
626
626
17 JANUARY 2017
626
626
Alum.
606
626