Multifunction Documenting Process Calibrator MULTIFUNCTION CALIBRATORS Accuracy up to ±0.006% rdg Light, Rugged, and Ergonomic for Field Use Push & Lock, TC and 4 mm Industrial Plug Connection Dual Channels High Accuracy Thermometer Internal / External Pressure Modules Programmable Tasks In-Line Digit Setting Large Graphic Backlighted Display Simultaneous Measure and Simulation for TRX Calibration Real-Time Clock with Memory for In-Field Calibration Procedures ("as found" + "as left") Built-in Environmental Condition Module for Ambient T, rH% and Barometric Pressure CalpMan 2007 Software for Automatic Calibration and Documenting in Compliance with ISO9001 n tro Instrum e dQ ste m Eu ro fie s nt Q rti Ce Bulletin 08-40.3 E - ed. 04-2007 ATEX Compliant Model ATEX Ex II 1G EEx ia IIC T4 (-20°C Tamb +50°C) X uality Sy www.eurotron.com All descriptions are related to full options instrument. See latest page for the different configurations. MULTIFUNCTION CALIBRATORS MicroCal 20 DPC Introduction Programmable generator l Autoramp and Autostep capability with Start, End, and Step programmable parameters l Single and continuous cycle with Start, End, Rises, Soaks, and Falls programmable parameters l the signal value setting uses a unique in-line single-digit setting mode or a direct numeric entry l direct keypad access to n.10 programmable memory stored values The MicroCal 20 DPC (Documenting Process Calibrator) Series are rugged hand tools for calibration maintenance and trouble shooting of virtually all the control process instrumentation. The MicroCal 20 DPC series features: l Calibrate temperature, pressure, current dc, voltage dc, frequency and resistance l Dual channel display for simultaneous measure/source l Measure and source 14 type of thermocouple and 10 RTD's l 24 Vdc loop power supply (12 Vdc on IS models) l Connection for internal and external pressure module up to 700 bar l Pressure switch test and leak test l Hold, zero, scale, Minimun, Maximum and Average l Automatic Ramp/Step with programmable Time, Step and Soak l HART ability for Smart Transmitters l Dual channel input and extended accuracy on XP models l Supports customized PRT's curve for enhanced temperature measurement l Documenting capabilities using CalPMan 2007 software Package l Scalable 4-20 mA measure/source into effective engineering unit End Increment Start Rise Break Fall Transmitter simulation program The instrument can be used as a temporary signal converter replacement. Any input signal (electric or pressure) can be converted into a 4-20 mA output. The galvanic insulation between the input and output channels allow also to use of this feature on the process. Built-in calculator A special calculator function is integrated in MicroCal 20 DPC. You can read the value from the input channel, operate on it, and then write the result on the output channel. All standard math functions are included. Built-in environmental module To compliant the ISO9000, ambient temperature, Relative Humidity, and Barometric pressure sensors can measure environmental condition (EC) parameters to be included in calibration report. The module is not available on IS models. Multichannel Data logging The calibrator can be used as a multichannel datalogger for electrical and pressure signals. The graphic mode allows you to display the trend; the Replay function allows you to generate the electrical signal using the data stored. The LogMan PC software allows the data storage in the hard-disk. both the channels and the display (including input and output values too). In this way the work on field is simpler and quicker. Pressure modules (INT & EXT) Single or dual range internal pressure modules can be configured to provide a lot of combinations for gauge, absolute and differential pressure measurements. External interchangeable pressure module can be connected to extend the pressure range up to 700 bar. The calibrator includes 23 selectable pressure units. Transmitter Calibration The MicroCal 20 DPC can be configured to easily manage the check and the calibration of any pressure and temperature transmitter. The wide display lets you simultaneously display the input and output values and to select the right units for the transmitter under test. The current or voltage reading can be scaled/converted in % of span or in the engenieristic unit to simplify the verification operations. The measuring circuit is also able to power the loop for a direct connection with the transmitter under test. With the optional communication HART module it is also possible to verify and calibrate smart transmitters. All the MicroCal 20 capabilities let the calibrator useful for all the checks and calibration activities. Pressure mbar bar Pa psi mmH20 Press enter chP 100.05 ch1 P1 in X mbar mbar 100.000 TASK The MicroCal 20 DPC can store and recall up to 10 complete instrument configurations. By pressing 2 keys only you can store or recall the configuration of 14 All descriptions are related to full options instrument. See latest page for the different configurations. Multifunction Calibrator for Documenting the Verification and the Certification activity "Excellence in measurements" Advanced Features Software Switch test CalpMan 2007 Temperature, signal and pressure switches can be tested using this advanced procedure. The calibrator will hold the display reading when the contact changes status. For over 20 years, Eurotron Instruments has combined its own ISO 9001, electric, thermoelectric and pressure measurements, and development of software application experiences. CalpMan 2007 has been designed to be used industries, where there are both laboratory and maintenance on field needs. The CalPMan 2007 is a WindowsTM 2000/XP software designed to plan, manage and document all the calibrations and the certifications of the process instrumentation. The software can manage the automatic procedures of the Eurotron calibrators. Two software versions are available: the CalpMan 2007 and the CalpMan 2007 Advanced. The main features are: ¡ Easy to use; ¡ Compliant with ISO9001 requirements; ¡ Standards and instruments expired date management; ¡ Automatic procedure run ¡ Built-in communication with documenting calibrators ¡ Traceable and editable calibration documents ¡ Database backup/Restore ability Leak Test This procedure allows you to measure the pressure fall in a programmable time interval. MULTIFUNCTION CALIBRATORS LogMan WindowsTM software to download logged data from internal memory to PC. Data can be saved on disks, loaded from disks, exported in Excel format file. LinMan WindowsTM software to setup the instrument with TC, RTD special linearization. The program allows highly accurate temperature measurement with a calibrated Pt100/TC loading the coefficients of the Calibration Report. The CalpMan 2007 Advanced has the following advanced features: ¾ Up to 3 instruments of simultaneous management; ¾ Advanced control of the test point; ¾ Multi-parameter procedures run; ¾ Simultaneous certification of more than one temperature sensors; ¾ Password manager and advanced data security ability. Module for MicroCal T Series FIVE STEPS FOR IN-FIELD DOCUMENTING CALIBRATION The MicroCal 20 is able to directly control a MicroCal T Series calibrator with this module. It is also possible execute fully automatic "off-line" procedures. the procedure 2 Transfer into the calibrator 1 Prepare the procedure using the CalPMan Software OFF_Pt100 1/5 Ref:100.0°C Ref:In 100.00 °C Act:In 101.50 °C Limit: +1.00 °C Error: +1.50 °C Print the report 5 3 Select the instrument (TAG) and run the procedure 4 Transfer the results on a PC The MicroCal 20 is a documenting calibrator able to load test strategies using the CalPMan 2007 software. It can run them and store the results automatically, calculate the errors, highlight the out of range points, and download data on a PC to store them and to generate different reports. The calibrator internal memory can store a whole week procedures. 15 All descriptions are related to full options instrument. See latest page for the different configurations. MULTIFUNCTION CALIBRATORS MicroCal 20 DPC LCD Graphic Display External Interchangeable Pressure Modules Connection for remote "SMART" pressure modules. Calibration matrix and range are stored on the sensor. Gauge, Absolute and Differential models available. Accuracy ±0.025% F.S. Keypad Large display with text and graphic capabilities. The rugged LCD is protected by a polycarbonate window from scratches and impacts. 19 key sealed rubber keypad, for direct access to the main functions of the instrument. Direct Up/Down Keys 5 dedicated keys for directly increase/decrease the value of the output signal. Two Internal Pressure Sensors Single or Dual AISI316 built-in pressure sensors (up to 20bar). Gauge, Absolute and Differential models available. Barometric reference sensor capability. Accuracy ±0.025% F.S. Environmental Conditions Module (EC) * You can include in documenting report the ambient temperature, pressure and the relative humidity. Powerful Documenting Capability Automatic Backlight Sensor Only ONE KEY to enter in Calibration Procedure Mode. Select the TAG and run the calibration procedure. All procedure data are loaded from the PC and the Calibration report can be downloaded to the PC with the CalpMan software. The photoelectric sensor will detect dark condition switching on backlight when necessary. Manual operation is also available. 16 * Battery Charger Modular for a Total Flexibility MULTIFUNCTION CALIBRATORS "Excellence in measurements" 2 Channels Dual simultaneous IN/OUT channels. mV, V, mA (active and passive loop), TCs, 3/4w RTDs, Frequency, Pulse. High accuracy, high repeatability and low drift. Mini-DIN TC Connector Integrated HART© Ability The MicroCal 20 DPC has a built-in option for HART calibration and maintenance. No external adapter is required. It supports a wide instruction set: Four operative mode: measure, simulate, measure/simulate and measure/measure. (XP model only) Universal Commands available for all process instruments like the model and the manufacturer reading, the primary variable (PV) and the output current reading. Isothermic binding post for TC's with Rj compensation. Advanced Commands available on many (but not for all) instruments like the multiple variables and the damping reading, and the run of the Loop Test. Specific Commands available on few instruments (verify the updated list on the website) like the sensor trim. The transmitter upgrade can be run in a simple and quick way using the PC software and the RS232/USB serial cable. Capabilities Basic Plus XP • • • • • • ±0.02% ±0.01% ±0.006% • • • • • • • • • • • mA, V, T/C's, RTDs, Hz, W Measure / Source Basic Accuracy (rdg) Dual Channel Display • • Dual Input INT pressure module EXT pressure module Loop P.S. HART ability Documenting capability EC Module RS232 interface Remote Rj input Digital HART remote input Switch test external contact input * * * • • • • • • • • Intrinsecally Safe The Intrinsecally Safe for zone 0 with ATEX certification, class II 1G EEx ia IIC T4 (-20°C TAmb + 50°C) X is available for IS model. * Not available on IS model 17 All descriptions are related to full options instrument. See latest page for the different configurations. MULTIFUNCTION CALIBRATORS MicroCal 20 DPC Specifications Measure or Source Voltage Input impedance: >10 MW for ranges up to 2000 mV f.s. >500 kW for ranges up to 20 V f.s. Output impedance (emf output): less than 0.5W with a maximum current of 0.5 mA Output noise (at 300 Hz): <2 µVpp for ranges up to 200 mV f.s., <10 µVpp for ranges up to 2000 mV f.s. <80 µVpp for ranges up to 20 V f.s. Report of Calibration Each MicroCal is factory calibrated and certified against Eurotron Standards, which are periodically certified by an Internationally recognised Laboratory to ensure traceability, and shipped with a Report of Calibration stating the nominal and actual values and the deviation errors. Firmware The firmware is stored on a flash memory and allows a fast and easy upgrade of the instrument using the USB cable and the STFlash software. Measure or Source Current Input impedance: <20 W at 1 mA Maximum load resistance: 1000W at 20 mA 600W at 21 mA (IS model) Loop Supply: 24V ± 5 % 12V ± 5 % (IS model) Over-Voltage protection The unit is equipped with an advanced system including thermal fuse (auto repair, do not need replacement), high voltage suppressor and resistor-diode voltage limiter. Measure or Source Resistance and RTDs Connections: 2, 3 and 4 wires Source resistance effects: ±1 µV error for 1000W source resistance Rtd and W simulation excitation current: from 0.100 to 4 mA without incremental error Rtd and W measurement excitation current: 0.2 mA Rtd cable compensation: up to 100 mW (for each wire) Rtd cable compensation error (Pt100): ±0.005°C/ W of total wire Maximum load resistance: 1000 W at 20 mA 600 W at 20 mA (IS model only) EMC Conformity The instrument fulfils the prevision of the directive 89/336/CEE Electromagnetic Compatibility. Quality system Research, development, production, inspection and certification activities are defined by methods and procedures of the Eurotron Quality System inspected for compliance and certified ISO9001 by GASTEC, a Dutch notified body. Measure or Source Thermocouples Engineering unit: °C/°F/K selectable Resolution: 0.01°C / 0.01°F Temperature scale: ITS90 and IPTS68 selectables Reference junction compensation: internal automatic from -10 °C to +55 °C external adjustable from -50 °C to +100 °C remote with external Pt100 from -10°C to +100 °C (only on XP model) Rj compensation drift: ± 0.002°C/°C (from -10 °C to +45 °C) - Class A Pt100 Input impedance (Tc ranges): >10 MW "Push & Lock" binding posts The multi-connection binding posts is an exclusive project designed to connect the calibrator in a simpler and faster way. The 3 different connection system available are: ¾ Standard 4 mm industrial plugs ¾ Mini isothermic TC's connectors ¾ Push & Lock system for wires Frequency Input impedance:>500KW Pressure Pressure media: AISI 316 SS compatible fluids (water, gas, and oil) Temperature compensation: Automatic with built-in calibration matrix. Engineering units: mbar, bar, Pa, hPa, kPa, MPa, kg/cm2, kg/m2, psi, mmH2O, cmH2O, mH2O, Torr, 2 atm, lb/ft , inH2O, ftH2O, mmHg, cmHg, mHg, inHg, programmable. Accuracy: the above accuracies are stated for 365 days and includes non linearity, histeresis, and repeatability. The average temperature coefficient, inside the temperature compensated range, is ±0.002% of rdg/°C (w.t.r. +23°C/+73°F). 18 Compensation temperature range: +0 to +45°C (+32°F +113°F) Internal sensors Accuracy: ±0.025% F.S. Ranges: see table on ordering code Resolution: see table on ordering code Overpressure: 125% F.S. Port: (female) 1/8" BSP External modules Accuracy: ±0.025% F.S. Ranges: see table on ordering code Resolution: see table on ordering code Overpressure: 125% F.S. Port: (male) 1/4" BSP Connection wire lenght: 2 meters Advanced Functions Calculation functions: hold, max, min, offset, zero, average In/Out data memory: 10 data with manual or automatic recall Convert function: displays the electrical equivalent of the engineering unit Scale factor: setting with zero and span programmable within -399999 and +999999 Square root: in combination with scale factor General Specifications Calibration: self learning technique with automatic procedure Channel 1-Channel 2 insulation: 250 Vdc Common mode rejection: 140 dB at ac operation Normal mode rejection:60 dB at 50/60 Hz Display: graphic LCD display with automatic and manual backlight device (not available on IS model) Measurement sampling time: 250 ms Digital interface: full bidirectional RS232 Power supply: external charger and rechargeable Ni-MH battery Battery life (typical): 10 h (8 h on IS model) on Tc and mV input/output (backlight Off) 4 h (3 h on IS model) with 20 mA simulation (backlight Off) Recharging time (typical): 5 h (8 h on IS model) at 90% and 6 h (10 h on IS model) at 99% with instrument switched off. Battery charge indication: bar graph on the LCD display (flashing on charge) - not available on IS model Line operation: 100V - 120 V - 230V - 240 Vac with the external battery charger Line transformer insulation: 2500 Vac Operating environment temperature range: from -10 °C to +55 °C (from -10°C to +50°C on IS model) Storage temperature range: from 0 °C to +60 °C (excluding batteries) Humidity: max 95%RH non condensing Case: Injection moulded policarbonate case (injection molded ATEX approved material on IS model) Sealing: IP54 Weights: nett 1.4 Kg gross 2.5 Kg Dimensions: 290x98x57 m All descriptions are related to full options instrument. See latest page for the different configurations. Multifunction Calibrator for Documenting the Verification and the Certification activity "Excellence in measurements" MULTIFUNCTION CALIBRATORS Ranges and Accuracy Measure or Source Tc J Range -210 to 1200°C -350 to 2200°F Tc K -270 to 1370°C -454 to 2500°F Tc T -270 to 400°C -454 to 760°F Tc R -50 to 1760°C -60 to 3200°F Tc S -50 to 1760°C -60 to 3200°F Tc B 50 to 1820°C 140 to 3310°F Tc C 0 to 2300°C 32 to 4170°F Tc G 0 to 2300°C 32 to 4170°F Tc D 0 to 2300°C 32 to 4170°F Tc U -200 to 400°C -330 to 760°F Tc L -200 to 760°C -330 to 1400°F Tc N -270 to 1300°C -450 to 2380°F Tc E -270 to 1000°C -450 to 1840°F Tc F 0 to 1400°C 32 to 2560°F Pt100 IEC -200 to 850°C OIML, a =.3926 -330 to 1570°F Pt100 -200 to 650°C a =.3902 -330 to 1210°F Pt100 -200 to 600°C JIS SAMA -330 to 1120°F Pt200 -200 to 850°C -330 to 1570°F Pt500 -200 to 850°C -330 to 1570°F Pt1000 -200 to 850°C IEC OIML -330 to 1570°F Cu10 -70 to 150°C -100 to 310°F Cu100 -180 to 150°C -300 to 310°F Ni100 -60 to 180°C -80 to 360°F Ni120 0 to 150°C 32 to 310°F mV -20 to 200mV V -0.2 to 2V -2 to 20V*** mA 0 to 50mA** mA (IN CH1) -5 to 50mA W (IN) 0 to 500W 0 to 5000W W (OUT)**** 0 to 500W 0 to 5000W Frequency 1 to 200 Hz 1 to 2 kHz 1 to 20 kHz Pulse 0 to 106 Accuracy Resolution MicroCal 20 DPC basic 0.01 °C* 0.01 °F 0.01 °C* 0.01 °F 0.01°C* 0.01 °F 0.1°C 0.1°F 0.1°C 0.1°F 0.1°C 0.1°F 0.1°C 0.1°F 0.1°C 0.1°F 0.1°C 0.1°F 0.01°C 0.01°F 0.01°C 0.01°F 0.01°C 0.01°F 0.1°C 0.1°F 0.1°C 0.1°F 0.01°C 0.01 °F 0.01°C 0.01 °F 0.01°C 0.01 °F 0.1°C 0.1°F 0.1°C 0.1°F 0.01°C 0.01°F 0.1°C 0.1°F 0.1°C 0.1°F 0.1°C 0.1°F 0.1°C 0.1°F 1µV 10µV 100µV 0.1µA 0.1µA 10mW 100mW 10mW 100mW 0.001Hz 0.01Hz 0.1Hz 1 count MicroCal 20 DPC plus MicroCal 20 DPC XP ±(0.02% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.02% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.02% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.02% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.02% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.02% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.02% rdg. + 0.2°C) ±(0.01% rdg. + 0.2°C) ±(0.01% rdg. + 0.2°C) ±(0.02% rdg. + 0.4°F) ±(0.01% rdg. + 0.4°F) ±(0.01% rdg. + 0.4°F) ±(0.02% rdg. + 0.2°C) ±(0.01% rdg. + 0.2°C) ±(0.01% rdg. + 0.2°C) ±(0.02% rdg. + 0.4°F) ±(0.01% rdg. + 0.4°F) ±(0.01% rdg. + 0.4°F) ±(0.02% rdg. + 0.3°C) ±(0.01% rdg. + 0.3°C) ±(0.01% rdg. + 0.3°C) ±(0.02% rdg. + 0.6°F) ±(0.01% rdg. + 0.6°F) ±(0.01% rdg. + 0.6°F) ±(0.02% rdg. + 0.2°C) ±(0.01% rdg. + 0.2°C) ±(0.01% rdg. + 0.2°C) ±(0.02% rdg. + 0.4°F) ±(0.01% rdg. + 0.4°F) ±(0.01% rdg. + 0.4°F) ±(0.02% rdg. + 0.3°C) ±(0.01% rdg. + 0.3°C) ±(0.01% rdg. + 0.3°C) ±(0.02% rdg. + 0.6°F) ±(0.01% rdg. + 0.6°F) ±(0.01% rdg. + 0.6°F) ±(0.02% rdg. + 0.3°C) ±(0.01% rdg. + 0.3°C) ±(0.01% rdg. + 0.3°C) ±(0.02% rdg. + 0.6°F) ±(0.01% rdg. + 0.6°F) ±(0.01% rdg. + 0.6°F) ±(0.02% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.02% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.02% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.02% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.02% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.02% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.02% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.02% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.02% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.02% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.02% rdg. + 0.05°C) ±(0.01% rdg. + 0.05°C) ±(0.01% rdg. + 0.05°C) ±(0.02% rdg. + 0.09°F) ±(0.01% rdg. + 0.09°F) ±(0.01% rdg. + 0.09°F) ±(0.02% rdg. + 0.05°C) ±(0.01% rdg. + 0.05°C) ±(0.01% rdg. + 0.05°C) ±(0.02% rdg. + 0.09°F) ±(0.01% rdg. + 0.09°F) ±(0.01% rdg. + 0.09°F) ±(0.02% rdg. + 0.05°C) ±(0.01% rdg. + 0.05°C) ±(0.01% rdg. + 0.05°C) ±(0.02% rdg. + 0.09°F) ±(0.01% rdg. + 0.09°F) ±(0.01% rdg. + 0.09°F) ±(0.02% rdg. + 0.15°C) ±(0.01% rdg. + 0.15°C) ±(0.01% rdg. + 0.15°C) ±(0.02% rdg. + 0.27°F) ±(0.01% rdg. + 0.27°F) ±(0.01% rdg. + 0.27°F) ±(0.02% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.02% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.02% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.01% rdg. + 0.1°C) ±(0.02% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.01% rdg. + 0.2°F) ±(0.02% rdg. + 0.4°C) ±(0.01% rdg. + 0.4°C) ±(0.01% rdg. + 0.4°C) ±(0.02% rdg. + 0.7°F) ±(0.01% rdg. + 0.7°F) ±(0.01% rdg. + 0.7°F) ±(0.02% rdg. + 0.05°C) ±(0.01% rdg. + 0.05°C) ±(0.01% rdg. + 0.05°C) ±(0.02% rdg. + 0.09°F) ±(0.01% rdg. + 0.09°F) ±(0.01% rdg. + 0.09°F) ±(0.02% rdg. + 0.05°C) ±(0.01% rdg. + 0.05°C) ±(0.01% rdg. + 0.05°C) ±(0.02% rdg. + 0.09°F) ±(0.01% rdg. + 0.09°F) ±(0.01% rdg. + 0.09°F) ±(0.02% rdg. + 0.05°C) ±(0.01% rdg. + 0.05°C) ±(0.01% rdg. + 0.05°C) ±(0.02% rdg. + 0.09°F) ±(0.01% rdg. + 0.09°F) ±(0.01% rdg. + 0.09°F) ±(0.02% rdg. + 3 µV) ±(0.01% rdg. + 3 µV) ±(0.006% rdg. + 3 µV) ±(0.02% rdg. + 10 µV) ±(0.01% rdg. + 10 µV) ±(0.006% rdg. + 10 mV) ±(0.02% rdg. + 100 µV) ±(0.01% rdg. + 100 µV) ±(0.006% rdg. + 100 µV) ±(0.02% rdg. + 0.4µA) ±(0.01% rdg. + 0.4µA) ±(0.01% rdg. + 0.4µA) ±(0.02% rdg. + 0.4µA) ±(0.01% rdg. + 0.4µA) ±(0.01% rdg. + 0.4µA) ±(0.02% rdg. + 12mW ) ±(0.01% rdg. + 12mW ) ±(0.008% rdg. + 12mW ) ±(0.02% rdg. + 120mW ) ±(0.01% rdg. + 120mW ) ±(0.008% rdg. + 120mW ) ±(0.02% rdg. + 20mW ) ±(0.01% rdg. + 20mW ) ±(0.008% rdg. + 20mW ) ±(0.02% rdg. + 200mW ) ±(0.01% rdg. + 200mW ) ±(0.008% rdg. + 200mW ) ±(0.005% rdg.+0.001Hz) ±(0.005% rdg.+0.001Hz) ±(0.005% rdg.+0.001Hz) ±(0.005% rdg.+0.01Hz) ±(0.005% rdg.+0.01Hz) ±(0.005% rdg.+0.01Hz) ±(0.005% rdg.+0.1Hz) ±(0.005% rdg.+0.1Hz) ±(0.005% rdg.+0.1Hz) NOTES: The relative accuracies shown above are stated for 360 days and the operative conditions are from 18 to 28°C Typical 2 year relative accuracy can be estimated by multiplying the "% of reading" specifications by 1.4. All input ranges: additional error ±1 digit. Eurotron traceability chart and uncertainty can be supplied on request. * Resolution is 0.1°C with temperature lower than -200°C. ** 21mA max. on passive current loop, and for the IS model. *** IS model channel 2 source Max 11 V. **** IS model ohm generation: additional error: ±20 mW on 500 W range ±200 mW on 5 kW range 19 All descriptions are related to full options instrument. See latest page for the different configurations. MicroCal 20 DPC 4 Models for the Process and for the Laboratory Ordering Codes Accessories Standard packing includes: calibrator, rubber holster, charger, instruction manual and report of calibration. EXTERNAL PRESSURE MODULES - AISI 316SS - ±0.025% F.S. GAUGE EE812009 from -100 to 100 mbar (1.5 PSI) res. 0.001mbar EE812010 from -500 to 500 mbar (7 PSI) res. 0.01mbar EE812011 from -0.95 to 1 bar (15 PSI) res. 0.01mbar EE812012 from -0.95 to 2 bar (30 PSI) res. 0.01mbar EE812013 from -0.95 to 7bar (100 PSI) res. 0.1mbar EE812014 from -0.95 to 20 bar (300 PSI) res. 0.1mbar EE812015 from -0.95 to 35 bar (500 PSI) res. 1mbar EE812016 from 0 to 70 bar (1000 PSI) res. 1mbar EE812017 from 0 to 150 bar (2000 PSI) res. 1mbar EE812018 from 0 to 350 bar (5000 PSI) res. 10mbar EE812019 from 0 to 700 bar (10000 PSI) res. 10mbar 3925 basic - A - 00 - C - D MicroCal 20 DPC basic: ±0.02% rdg 2 channel (IN - OUT) multifunction calibrator 3925 plus - A - BB - C - D MicroCal 20 DPC plus: ±0.01% rdg 2 channel (IN - OUT) multifunction calibrator 3925 XP - A - BB - C - D MicroCal 20 DPC XP: ±0.006% rdg 2 channel (IN - IN/OUT) multifunction calibrator Intrinsically Safe Models 3926 basic - A - 00 - C - D MicroCal 20 DPC IS basic: ±0.02% rdg 2 channel (IN - OUT) multifunction calibrator 3926 plus - A - BB - C - D MicroCal 20 DPC IS plus: ±0.01% rdg 2 channel (IN - OUT) multifunction calibrator 3926 XP - A - BB - C - D MicroCal 20 DPC IS XP: ±0.006% rdg 2 channel (IN - IN/OUT) multifunction calibrator Table A Basic plus XP 1 1 2 2 3 3 4 4 5 5 Table B Basic 0 -------- Line charger 120V 50/60 Hz with USA plug 230V 50/60 Hz with Schuko plug 230V 50/60 Hz with UK plug 230V 50/60 Hz with European plug 100V 50/60 Hz with USA/Japan plug Internal pressure - AISI316SS - ±0.025% FS plus XP 0 None 2 -100 to 100 mbar Gauge res. 0.001mbar 3 -500 to 500 mbar Gauge res. 0.01mbar 5 -0.95 to 2 bar Gauge res. 0.01mbar 5A 2 bar Absolute res. 0.01mbar 6 -0.95 to 7 bar Gauge res. 0.1mbar 7 -0.95 to 20 bar Gauge res. 0.1mbar 7A 20 bar Absolute - res. 0.1mbar IMPORTANT: Basic model cannot install internal pressure sensors. plus and XP models can install up to 2 internal pressure sensors Table C Basic 0 1 2 3 3 Table D Basic 1 from 0 to 2 bar (30 PSI) from 0 to 20 bar (300 PSI) SOFTWARE BB530203 BB530212 BB260198 BB260199 BB260215 BB530204 RS232 cable USB cable LogMan-Data Logging software LinMan-Linearization software CalpMan 2007 - Calibration Procedure Manager MicroCal T series communication module EE300040 BB300122 EE300204 EE300205 BB880056 EE300284 EE480054 EE480055 Test leads kit for electric signal TC, J, K, T, S compensated cables Kit Mini DIN TC, J, K, T, S female connector set Mini DIN TC, J, K, T, S male connector set Rubber holster Pedestral for rubber holster 1/4" BSP pressure adapter kit (1/2" M, 1/2" F, 3/8" F, 1/8" F) 1/4" NPT pressure adapter kit (1/8" F, 1/4" F, 3/8" F, 1/2" F) res. 0.01mbar res. 0.1mbar BB880033 Aluminium carrying case BB880048 Vinyl case with shoulder strap BB880043 Compact vinyl carrying case with shoulder strap. F3280013 Manual pump for vacuum and pressure up to 2 bar EE300280 Adapter Kit for internal pressure module F3280019 Manual pump for vacuum and pressure up to 40 bar Options plus XP 0 1 2 ABSOLUTE EE812020 EE812021 none HART protocol EC module (T + RH% + barometric measurements) - not available on IS model Extended memory - not available on IS models EE300281 Adapter Kit for internal pressure module EE170049 Adapter Kit for external pressure module F3280015 Manual pump for vacuum and pressure up to 700 bar Report of calibration plus XP 1 EE372008 High Pressure tube for pump F3280015 Eurotron Certificate EE170049 Adapter Kit for external pressure module 20 All descriptions are related to full options instrument. See latest page for the different configurations. Specifications may change without notice. MULTIFUNCTION CALIBRATORS
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement