Hydrolevel Fuel Smart 3200-Plus boiler temperature and low water cut-off control, OS-100 outdoor sensor kit INSTALLATION INSTRUCTIONS and OPERATING MANUAL

Below you will find brief information for boiler temperature and low water cut-off control Fuel Smart 3200-Plus. The Fuel Smart 3200-Plus is a boiler temperature and low water cut-off control designed for cold start and tankless coil boilers. Features Thermal Targeting™ technology and Thermal Pre-Purge capability. Outdoor Reset Ready - Provides Outdoor Reset and Warm Weather Shut-Down capability with the addition of Hydrolevel OS-100 Outdoor Sensor Kit(sold separately) and Universal Design - Replaces common cold-start and triple-action Aquastats*.

PDF Download
Document
Fuel Smart 3200-Plus Installation and Operation Manual | Manualzz

Advertisement

Advertisement

Advertisement

Key features

  • Thermal Targeting™ technology
  • Thermal Pre-Purge capability
  • Outdoor Reset Ready
  • Universal Design
  • Operating Indicators
  • Prioritizes Domestic Hot Water
  • Reduces Condensation

Frequently asked questions

Thermal Targeting technology analyzes thermostat activity and continually evaluates how much heat the house requires. When it is very cold outside, the heat demand is high and the Fuel Smart HydroStat will raise the boiler’s Target temperature to provide needed heat to the home. When the outside temperature is milder, the heat demand is lower. During these periods, the Fuel Smart HydroStat will lower the boiler’s Target temperature – saving fuel – while continuing to provide comfort to the house.

Thermal Pre-Purge is designed to maximize boiler efficiency. When activated, the control will supply latent heat that may remain in the boiler from a previous run cycle to the next heating zone that calls. The control monitors how quickly the boiler temperature is declining and activates the burner only when it determines that the latent heat is insufficient to satisfy the call.

The Low Water Cut-Off function provides protection against potentially dangerous low water conditions when installed with the Hydrolevel Electro-Well™. This function prevents the burner from firing when the boiler water level falls below a certain point.

The Economy Feature is factory set for a 1 zone heating system. To adjust, turn the ECONOMY Dial until the number displayed equals the number of heating zones. Do not include indirect water heaters in the number of heating zones. The Economy Feature conserves fuel by reducing boiler temperature (see “How Thermal Targeting Works” on page 7). If the heating system is unable to supply needed heat to the house, the ECONOMY Dial should be turned to a lower setting (example: In a three zone house, turn the dial to 2 or 1). Conversely, if the boiler provides adequate heat, added fuel savings can be achieved by selecting a higher setting (example: 4 or 5).