3 GHz Spectrum Analyzer HM5530

3 GHz Spectrum Analyzer HM5530
3 GHz Spectrum Analyzer
HM5530
Frequency range 100 kHz to 3 GHz
Test signal 50 MHz
Amplitude measurement range -110 dBm to +20 dBm
Phase synchronous direct digital frequency synthesis
Resolution bandwiths (RBW): 9 kHz, 120 kHz and 1 MHz
Externally triggered
AM signal (zero span)
YIG oscillator
Pre-compliance emi measurements
Software for extended measurement functions for emi
measurements included
RS-232 Interface, optional: RS-232/USB
Amplitude modulated
3 GHz signal
3 GHz Spectrum Analyzer HM 5530
(Valid at 23 degr. C after a 30 min. warm-up period.)
Frequency characteristics
Frequency range:
100 kHz to 3 GHz
Frequency generation:
TXCO with DDS
(Digital Frequency Synthesis)
Stability:
± 5 ppm
Ageing:
± 1 ppm/year
Frequency resolution:
1 kHz (611⁄22-digit readout)
Center frequency range:
0 to 3 GHz
Tolerance of center frequency: ± 1 kHz
Span setting range:
0 (zero span) and 1 to 3000 MHz
Amplitude characteristics
Display range:
-110 dBm to +20 dBm
Scaling, units:
10 or 5 dB/div, dBm, dBmV,
dBμV selectable
Dynamic range:
80 dB (10 dB/div), 40 dB (5 dB/div)
Amplitude frequency response (ATT 10 dB, zero span, 1 MHz-RBW
signal level –20 dBm):
±3 dB
Display (CRT):
8 cm x 10 cm
Display chracteristic:
logarithmic
Display units:
dB (dBm, dBmV, dBμV)
Input attenuator:
0 to 50 dB in 10 dB increments
Tolerance:
± 2 dB, referred to 10 dB
Maximum continuous input level:
Attenuation 0 to 50 dB:
+ 20 dBm (0.1 W)
Attenuation 0 dB:
+ 10 dBm
Maximum input dc voltage:
± 25 V
Reference level:
Adjustment range:
-110 dBm to +20 dBm
Tolerance (1500 MHz, ATT 10 dB, Zero Span,
RBW 1 MHz):
±1 dB
Min. average noise level (RBW 9 kHz):
150 kHz – 1.5 MHz:
-90 dBm
1.5 MHz – 2.6 GHz:
-100 dBm
2.6 GHz – 3.0 GHz:
-90 dBm
3rd order intermodulation (2 signals of):
–33 dBm each, frequency
difference › 3 MHz:
› 75 dBc
2nd order harmonic distortions (2nd harmonic at a signal level of -30 dBm,
ATT 0 dB, frequency difference › 3 MHz): › 75 dBc
Bandwidth dependent frequency response amplitude tolerance
amplitude tolerance (relative to RBW 1 MHz, zero span: ± 1 dB
Digitization:
± 1 Digit (0.4 dB) at 10 dB/div
scaling (average, zero span)
Marker/Deltamarker
Frequency resolution:
Frequency accuracy:
Amplitude resolution:
span/2000, max. 1 kHz, 611⁄22-digit
± (1 kHz + tolerance of center frequency
+ 0.02% x span)
0.4 dB, 311⁄2-digit
Bandwidths
Resolution bandwidths (RBW) at –6 dB: 1 MHz, 120 kHz, 9 kHz
Videobandwidth (VBW):
50 kHz, 4 kHz
with automatic selection of sweep time:
40, 80, 160, 320 und 1000 ms
Inputs/Outputs
Measuring input:
Input impedance:
VSWR (ATT 10 dB):
Testsignal output:
Output impedance:
Frequency:
Level:
Accuracy of level:
Supply voltage for
field probes:
Audio output (PHONE):
RS-232 interface:
External trigger input:
Digital signal:
Low level:
High level:
Functions
Keyboard input:
Rotary encoder input:
MAX HOLD:
AVG (average):
Reference spectrum:
SAVE/RECALL:
AM demodulation:
REMOTE:
Readout:
Miscellaneous
Display (CRT):
Acceleration voltage:
Trace rotation:
Ambient temperature range:
Storage temperature:
Power supply:
Safety class:
Dimensions (W x H x D):
Colour:
Weight:
N connector
50 Ω
typ. 1.5 : 1
N connector
50 Ω
50 MHz ± 1 kHz
-10 to 0 dBm in 0.2 dB increments
± 1 dB
6 VDC, max. 100 mA (2.5 mm jack)
3.5 mm jack
9-pin. sub-D
BNC connector
0 to +0.8 V
+2.5 V to +5.0 V
Center frequency, span, start frequency,
stop frequency, marker, deltamarker,
reference level, test signal level
Center frequency, span, start frequency,
stop frequency, marker, deltamarker,
reference level, test signal level intensity,
focus, trace rotation, volume
Peak detection
Averaging
memory depth 2 k x 8 Bit
Storage and recall of up to
10 instrument settings
for the PHONE output
Display of remote/local control
via RS-232 interface
8 parameter display fields, display of
keyboard inputs
D 14-363GY, 8 cm x 10 cm internal graticule
approx. 2 kV
adjustable on front panel
+10 to +40 °C
- 40 to +70 °C
105 to 254 VAC, 50 to 60 Hz,
approx. 37 W CAT II
I (EN/IEC 61010-1) with protective earth
285 x 125 x 380 mm Adjustable handle,
as a tilt-stand or for convenient carrying
techno-brown
approx. 6.5 kg
Accessories supplied: Line cord, manual, CD-ROM, HZ21 Adapter N male to
BNC female
Optional accessories:
HZ70 Opto-Interface (with optical fiber cable)
HZ520 Antenna
HZ530 Near Field Probe Set for EMI Diagnosis
HZ560 Transient Limiter
HZ575 75 /50 ohm-converter
w w w. h a m e g . co m
HM5530E/030906/ce · Subject to alterations · © HAMEG Instruments GmbH · ® Registered Trademark · DQS-certified in accordance with DIN EN ISO 9001:2000, Reg.-No.: DE-071040 QM
HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 800 0 · Fax +49 (0) 6182 800 100 · www.hameg.com · [email protected]
A Rohde & Schwarz Company
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement