Fire Alarm Systems

Contents

General Hints

General Information

1

Control Panels

IQ8Control

Extingishing System

2

Power Supplies

Power Supply Units

Voltage Converters

Batteries (Rechargeable)

Accessories

3

Displays and Operating Units

LED Indicator Panel

LCD Indicator Panel

System 3000

4

Network Technology

essernet

5

Hazard Management System

WINMAGplus

WINMAGLite

Difference WINMAGLite vs WINMAGplus

6

Automatic Detectors

Series ES Detect (Conventional)

Series IQ8Quad (Intelligent Addressable)

Intrinsically Safe

Base Series IQ8Quad, ES Detect

Accessories

7

Manual Call Points

Large Design (ABS)

Large Design (Aluminum)

Accessories for MCP large design

Small Design (ABS)

Accessories for MCP small design

Special Design

8

Transponders / Input & Output Modules

esserbus

9

Wireless Components

Wireless Modules

35-40

36

37

38-40

41-46

42-46

47-58

48-56

57

58

3-5

3-5

7-28

8-24

25-28

29-34

30-32

33

34

34

97-122

98-101

102-103

104-107

108-114

115-116

117-122

123-135

124-135

137-144

138-144

59-95

60-63

64-75

76-81

82

83-95

1

Contents

10

Detectors for Special Applications

Flame and Heat Detectors

Air Duct Detectors

Linear Heat Detectors

Linear Smoke Detectors

Aspirating Smoke Detectors

11

Alarm Devices

Conventional ENscape

Intelligent Addressable IQ8Alarm

Intrinsically Safe

Remote Indicators

12

Door Release System

Automatic Door Systems

Door Holding Devices

Triggering Devices

13

Installation & Service

Installation Accessories

Housings

14

Appendix

Planning Guide

Order Forms

Part Number Index

Index

145-188

146-153

154-156

157-163

164-171

172-188

189-208

190-196

197-206

207

208

209-218

210-212

213-217

218

219-226

220-224

225-226

227-245

228

229-234

235-237

238-245

2 www.hls-austria.com

General Hints

General Information

Contact us

Headquarters

Honeywell Life Safety Austria GmbH

Technologiestrasse 5, building F, 3rd floor

1120 Vienna, Austria

Phone: +43 1 600 60 30

E-mail: [email protected]

Internet: www.hls-austria.com

Czech Republic / Slovakia

Honeywell, spol. s r.o.

V Parku 2325/16

148 00 Prague 4 - Chodov, Czech Republic

Phone: +420 242 442 280

E-mail: [email protected]

Internet: www.hls-czech.com

Poland

Honeywell Sp.z.o.o.

Budynek Nefryt, Domaniewska 39

02-674 Warsaw, Poland

Phone: +48 22 313 09 70

E-mail: [email protected]

Internet: www.hls-poland.com

Romania

Honeywell Life Safety Romania S.R.L.

Upground - BOC Office Building

Str. George Constrantinescu nr. 3, building A, 4th floor

District 2, 020338 Bucharest, Romania

Phone: +40 31 224 36 10

E-mail: [email protected]

Internet: www.hls-romania.com

Russia

Honeywell ZAO

8th floor, Kievskaya str., 7

121059 Moscow, Russia

Phone: +7 495 7969 800

E-mail: [email protected]

Internet: www.hls-russia.com

Ukraine

FE Honeywell Ukraine

Office Center „IRVA“, Block A

Radyscheva str. 10/14

03680 Kiev, Ukraine

Phone: +380 44 351 15 50

E-mail: [email protected]

Internet: www.hls-russia.com

Honeywell Life Safety Romania S.R.L.

Salcâmilor str. 2 bis

305500 Lugoj, Romania

Phone: +40 256 35 00 00

E-mail: [email protected]

Internet: www.hls-romania.com

3

General Hints General Information

Abbreviations

The list below provides a brief explanation of various abbreviations used in this product guide.

ABIGA = integrated operating unit for alarm systems

Acc. = according to

Approx. = approximately

ATEX = EU directive for explosive atmosphere

BOSEC = Belgian institute for the approval of fire alarm-related products

BTS = base transceiver station

CNBOP = Polish research and development center for fire protection

DIBt

DIL

DIN

DIP

= German institute for technical approvals

= dual in line

= German institute for standardization

= dual in parallel

ECP = extinguishing control panel

EDP = ESSER data protocol

EMV = electromagnetic compatibility

EN = European Norm

EOL = end of line

ESPA = enhanced signaling protocol for

Ex alarm processes

= explosion proof / intrinsically safe

FACP = fire alarm control panel

FAS = fire alarm system

FB

FBF

= fire brigade

= fire brigade panel

FBOIU = fire brigade operating and indicating unit

FCT

FD

FDS

= fire control transponder

(input/output module)

= fire detection

= fire detection system

FIBS = fire brigade operating system

FO = fiber optic

FSA = door release system

GI

HMI

HU

= galvanic isolated

= human machine interface

= used for 19” rack, 1 HU = 44.45 mm

I/O

IP

IR

= input / output

= ingress protection rating

= infrared

LAN

LCD

LED

LF

= local area network

= liquid crystal display

= light emitting diode

= low frequency

LKM = air duct detector

LPCB = Loss Prevention Certification Board

LRS = high sensitivity aspiration detector

MCP = manual call point

MFAB = master box

MM = micromodule

NC

NO

= normally closed

= normally opened

OTG = optical, heat and gas

PCB pcs.

PL

PLC

= printed circuit board

= pieces

= powered loop

= programmable logic control

PM

PTB

= delay and verify functions

= national institute of natural and engineering sciences

PU = packaging unit

ROR = rate-of-rise heat detector

SEI

SHV

= serial essernet interface

= smoke heat ventilation module

SMD = surface mounted technology

SL = silent

SOC = switch-on control

SZI = single zone indicator

TAL

TM

USB

UV

VDE

VdS

VGA

VPP

= technical alarm module

= coincidence detection

= universal serial bus

= ultraviolet

= association for electrical, electronic and information technologies

= association of German property insurance companies

= video graphics array

= voltage peak-peak

4 www.hls-austria.com

General Hints

General Information

S ymbols used

= List of contents which the part number includes

= Information, important notice such as special versions, dependencies etc.

= Packing unit

= Available starting on

IP type of protection

The type of protection indicates the suitability of electric operating materials (for examp le, devices, lights and installation material) agai nst solid foreign objects and for various ambient conditions.

2

3

Levels of protection from contact and foreign bodies (first digit)

Digit Protection from contact

0

1

No protection

Protec tion from large-size d body parts

(diameter 50 mm)

Pr otection from foreign bodies

No protection

Large foreign bodies

(diameter from 50 mm)

Medium-size foreign bodies

(diameter from 12.5 mm)

4

Finger protec tion

(diameter 12 mm)

Tools and wires

(diameter from 2.5 mm )

Tools and wires

(diameter from 1 mm)

Small foreign matter

(diameter from 2.5 mm)

Granular foreign matter

(diameter from 1 mm)

5 (K ) Wire protection (as IP 4) dust-protec ted Dust acc umulation

6 (K ) Wire protection (as IP 4) dust-proof No ingress of dust

1

2

3

4

Levels of protection from water (second digit)

Dig it Pr otec tion from water

0 No protection

Protection from vertically dripping water

Protection from diagonally (15°) falling drip water

Protection from falling spray water up to 60°, against the vertica l

Protection agains t splashing water

5

6

Protection from hose water (nozzle) from any angle

Protection from strong hose water (flooding)

7 Protection from temporary submersion

8 Protection from permanent submersion

Example:

IP64: Completely dust-proof – protected against splashing water – nearly leak-proof.

5

Notes

6 www.hls-austria.com

Control Panels

IQ8Control

Extinguishing System

8

9

6

7

2

3

4

5

10

11

8-24

25-28

12

13

14

7

IQ8Control Panels IQ8Control C/Intelligent Addressable

IQ8Control C/Intelligent Addressable

Features

Max. two micromodules (system supports up to

254 digital loop addresses in total)

Max. two esserbus analog loop modules

Short circuit and open circuit resistant loop operation

Loop installation with I-Y(ST)Y 0.8 mm cable for a maximum length of 3.5 km

Up to 127 esserbus devices (fire detectors and/ or manual call points)/detector zones per loop

Up to 32 esserbus transponders/wireless transponders per loop

Up to 127 IQ8/FCT transponders per loop

Operation types TM and PM as per DIN VDE

0833 - 2 to avoid unwanted alarms being triggered

Fire brigade operating panel and alarm transmission unit interface on the peripheral module

Three common relays, freely programmable, monitored, floating for up to 24 V DC/1A (on the peripheral module)

TTY or RS 485 interface, optional RS 232

Integration in the short circuit and open circuit resistant essernet network with up to 31 fire detection panels depends on transmission rate

Connection to graphical supervisor WINMAG via serial essernet interface (SEI)

Operating panel with alphanumerical display

Large LCD display with 8 rows x 40 characters

Event memory for up to 10,000 events

All System 8000 micromodules are compatible

Printer interface for internal printer

Two batteries with monitoring circuit

Monitored input for external power supply unit

Additional features for powered loop

Max. 2 analog powered loop modules (System supports up to 254 digital loop addresses in total)

BUS powered, synchronously controlled, acoustic alarm signaling devices as per DIN EN

54-3 with alarm tone as per DIN 33404

Up to 48 powered loop base sounders (series

9200) per loop

Up to 32 powered loop IQ8Alarm per loop

Up to 48 IQ8Quad with alarm device per loop

Approval: VdS, CNBOP, BOSEC

VdS system certificate: S 294050

The IQ8Control C is an efficient fire alarm control panel for the property supervision of small to mid-sized objects facilitates simultaneous detection, control and alarm signaling both on the analog ring as well as on the spur.

Within the multi-functional IQ8Control C panel, the operation type (powered-loop or non-powered- loop) can be selected via a jumper located on the control panel power supply unit.

Depending on which loop operation type has been selected, the corresponding loop module/ modules are required.

Technical Data

Rated voltage

Rated frequency

Rated current

Quiescent current

Current consumption for ext. devices

Battery capacity

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

Declaration of Performance

230 V AC

50 ... 60 Hz

0.35 A (standard); 0.7 A (powered loop) approx. 215 mA (basic configuration without operating unit) approx. 230 mA (basic configuration with operating unit) max. 2 A @ 12 V DC

2 x 12 Ah, 2 x 26 Ah in extension housing

-5 °C ... 45 °C

-5 °C ... 50 °C

< 95 % (non-condensing)

IP30

ABS, 10 % glass fiber reinforced, V - 0 gray similar to Pantone 538 approx. 6.5 kg

W: 450 mm H: 320 mm D: 185 mm

DoP-20827130701

- The IQ8Control fire detection panels are fully compatible with FACP 8000 panels within essernet applications

- FACP 8000 micromodules are also compatible with IQ8Control devices

- Housing form and color comply with the FACP 8000 generation

- The IQ8Control panels can only be programmed with the tools 8000 software solution (Part

No. 789861) and the field bus interface (Part No. 789862.10) or directly via USB with the RS-

232 interface (Part No. 769828), with the field bus interface or the RS232 interface.

Combined with Part No. 808619.10 FSA transponder, the control panel can be used to control automatic door arrester systems in compliance with the German Institute for Construction Engineering (DIBt: Deutsches Institut für Bautechnik).

external equipment

Fiber optic converter

12V DC

IQ8Control C essernet

Loop length max. 1 km

(with repeater max. 3 km) esserbus -PLus

Loop length max. 3.5 km

Repeater

IQ8Control C esserbus transponder

Management System

XS Guard

Connection example

8 www.hls-austria.com

IQ8Control Panels IQ8Control C/Intelligent Addressable

Order Diagram FACP IQ8Control C/Intelligent Addressable

1.

Choice of the housing type

IQ8ControlC standard housing 808003

Slot for one micromodule as standard

IQ8ControlC for 19” cabinet 808139

2.

Choice of the control panel modules

(only 1 module at a time)

772478

Extension module with one additional micromodule slot

772479

Peripheral module

772477

Peripheral module with one additional micromodule slot

804382.D0

Analog loop module powered loop

784382.D0

Analog loop module

771670

Master box interface module

784840.10

essernet module 62.5kBd

3.

Choice of the micromodules

787531

3-relay module

784842

RS 232/TTY serial interface module

784385

Master box interface module

784841.10

essernet module 500kBd

4.

Choice of the operating front* language codes available:

01 Germany

02 England

03 Italy

04 Portugal

05 Poland

06 Spain

07 Austria

08 Netherlands

09 Czech Republic

10 Russia

11 Hungary

12 Denmark

13 Sweden

14 Croatia

15 France

16 Slovakia

17 Switzerland / French

18 Romania

19 Slovenia

20 Turkey

21 Greece

22 Belgium / Flemish

23 Belgium / Walloon

25 Arabic / English

27 Serbian

5.

Choice of a extension housing

(optional)

787532

3-relay common fault module

7860_ _

Operating front

7861_ _

Operating front w.

SZI f. 64 detector zones

7868_ _

Operating front with printer, w/o take-up reel*

7863_ _

Operating front for printer, w. take-up reel**

786000

SZI front for 192 detector zones

786100

Filler panel front, neutral for

IQ8Control C/M

788093

19” rack mounting kit for

SZI 192 detector zones

All operating fronts, except SZI 192 detector zones are suitable for both housing types

*Space for only 1 battery **Requires an additional extension housing

789300

Battery extension housing

787530

4-relay module

789302

Extension housing for SZI

192 detector zones

789301

Extension housing for batteries and

SZI 192 detector zones

8

9

6

7

2

3

4

5

12

13

10

11

14

9

IQ8Control Panels IQ8Control C/Intelligent Addressable

FACP IQ8Control C Standard and for 19" Racks

1

808003 FACP IQ8Control C

Basic design.

The operating front must be ordered separately and is not included in the price.

Housing with standard rear panel and front frame for operating panel fronts, interface board, power supply module, system software.

1

808139 FACP IQ8Control C for 19" rack

Same as 808003, but 19" version (7 HU) for rack installation.

The operating front must be ordered separately and is not included in the price.

FACP 808003 IQ8Control C, including 19" installation frame and flat cable for 19" installation.

10 www.hls-austria.com

IQ8Control Panels IQ8Control C/Intelligent Addressable

Accessories for FACP IQ8Control C

1

789300 Battery extension housing

Extension housing for additional batteries.

Technical Data

Ambient temperature

Storage temperature

Type of protection

Housing

Weight

Dimensions

-5 °C ... 45 °C

-10 °C ... 50 °C

IP 30

ABS, 10% glass fiber reinforced, V - 0 approx. 5 kg (without battery)

W: 450 mm H: 320 mm D: 185 mm

Batteries are not included and must be ordered separately.

Housing complete with battery rear panel, connecting cable for battery, mounting positions for two 12 V/

26 Ah batteries. Neutral front and material for attaching to the existing panel housing, battery connecting cables, 800 mm.

Assembling the housing parts

Take off the

4 standard covers.

Insert the

2 connecting elements.

Put the 2 housings on top of each other and push them together.

1

789301

1.

2.

Connection between the central housing and the extension housing

3.

Extension housing for batteries with 192 detector zones

Technical Data

Quiescent current

Current consumption

Ambient temperature

Type of protection

Housing

Color

Weight

Dimensions approx. 5 mA

1.5 mA when LED activated

-5 °C ... 45 °C

IP 30

ABS, 10% glass fiber reinforced, V - 0 gray similar to Pantone 538 approx. 5.5 kg (without battery)

W: 450 mm H: 320 mm D: 185 mm

This housing cannot be used if an operating module front with single zone indicator unit for

64 zones is already fitted. Batteries are not included and must be ordered separately.

A single zone indicator unit can only be used in connection with an operating module front.

Housing complete with battery rear panel, connecting cable for batteries, mounting positions for two 12 V

/ 26 Ah batteries, single zone indicator front for 192 detector zones and material for attaching to the existing panel housing.

8

9

6

7

2

3

4

5

12

13

10

11

14

11

IQ8Control Panels

1

789302

IQ8Control C/Intelligent Addressable

Extension housing for SZI 192 detector zones IQ8Control

The housing can be used to mount additional modules, e.g. an esserbus transponder.

Technical Data

Quiescent current

Current consumption

Ambient temperature

Type of protection

Housing

Color

Weight

Dimensions approx. 5 mA

1.5 mA when LED activated

-5 °C ... 45 °C

IP 30

ABS, 10% glass fiber reinforced, V - 0 gray similar to Pantone 538 approx. 5 kg

W: 450 mm H: 320 mm D: 185 mm

This housing cannot be used if an operating module front with single zone indicator unit for

64 zones is already fitted. A SZI unit can only be used in combination with an operating module front.

Housing complete with standard rear panel, single zone indicator front for 192 detector zones and material for attaching to the existing panel housing.

12 www.hls-austria.com

IQ8Control Panels IQ8Control M/Intelligent Addressable

IQ8Control M/Intelligent Addressable

Features

Max. five micromodules, with peripheral module

Part No. 772477, up to five esserbus analog loop modules (system supports up to 635 digital loop addresses in total)

Max. seven micromodules, with extension module Part No. 772476, up to seven esserbus analog loop modules (system supports up to

889 digital loop addresses in total)

Short circuit and open circuit tolerant loop operation

Loop installation with I-Y(ST)Y 0.8 mm cable for a maximum length of 3.5 km

Up to 127 esserbus devices (fire detectors and/ or manual call points)/detector zones per loop

Up to 32 esserbus transponders/wireless transponders per loop

Up to 127 IQ8/FCT transponders per loop

Operation types TM and PM as per DIN VDE

0833 - 2 to avoid unwanted alarms being triggered

Fire brigade operating panel and transmission interface on the peripheral module

Three common relays, freely programmable, monitored, floating for up to 30 V DC/1A (on the peripheral module)

TTY or RS 485 or RS 232 interface

Integration in the short circuit and open circuit resistant essernet network with up to 31 fire detection panels depends on transmission rate

Connection to graphical supervisor WINMAG via serial essernet interface (SEI)

Operating panel with alphanumerical display

Large LCD display with 8 rows x 40 characters

Event memory for up to 10,000 events

All Systems 8000 micromodules are compatible

Printer interface for internal printer

Two batteries with monitoring circuit

Monitored input for external power supply unit

Additional features for powered loop

Max. 6 analog powered loops and expandable up to 127 loop devices (per loop) in mixed mode

/ loop powered and non-loop powered (system supports up to 762 digital loop addresses in total)

esserbus PLus (Powered Loop) supplied, synchronously controlled, acoustic alarm signaling devices as per DIN EN 54 - 3 with alarm tone as per DIN 33404

Up to 48 powered loop base sounders (series

9200) per loop

Up to 32 powered loop IQ8Alarm per loop

Up to 48 IQ8Quad with alarm device per loop

Approval: VdS, CNBOP, BOSEC

VdS system certificate: S 294050

The IQ8Control M as an efficient fire alarm control panel (FACP) for the property supervision of mid-sized to large objects, facilitates simultaneous detection, control and alarm signaling both on the analog ring as well as on the spur.

The loop operation type of the panel (powered-loop or non-powered-loop) can be selected via a jumper located on the power supply card.

Depending on which loop operation type has been selected, the corresponding analog module/ modules should be used.

Technical Data

Rated voltage

Rated frequency

Rated current

Output voltage

Quiescent current

Current consumption for ext. devices

Battery capacity

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

Declaration of Performance

230 V AC

50 ... 60 Hz

0.35 A (standard); 0.7 A (powered loop)

12 V DC approx. 215 mA (basic configuration without operating unit) approx. 230 mA (basic configuration with operating unit) max. 2 A @ 12 V DC max. 2 x 12 V/26 Ah

-5 °C ... 45 °C

-10 °C ... 50 °C

< 95 % (non-condensing)

IP30

ABS, 10 % glass fiber reinforced, V - 0 gray similar to Pantone 538 approx. 11.5 kg

W: 450 mm H: 640 mm D: 185 mm

DoP-20827130701

- The IQ8Control fire detection panels are fully compatible with FACP 8000 panels within essernet applications

- FACP 8000 micromodules are also compatible with IQ8Control devices

- Housing form and color comply with the FACP 8000 generation

- The IQ8Control panels can only be programmed with the tools 8000 software solution (Part

No. 789861) and the field bus interface (Part No. 789862.10) or directly via USB with the RS-

232 interface (Part No. 769828), with the field bus interface or the RS232 interface.

Combined with 808619.10 FSA transponders, the control panel can be used to control automatic door arrester systems in compliance with the German Institute for Construction

Engineering (DIBt: Deutsches Institut für Bautechnik).

Network segment lenght max. 1 km

8

9

6

7

2

3

4

5

12

13

10

11

14

Application example

13

IQ8Control Panels IQ8Control M/Intelligent Addressable

Order Diagram FACP IQ8Control M/Intelligent Addressable

1.

Choice of the housing type

2.

Choice of the control panel modules

2 Extension modules or

1 Extension module

+

1 Peripheral module

Slot for one micromodule as standard

Wall housing

808004

772478

Extension module with one additional micromodule slot

772476

Extension module with three additional micromodule slots

772479

Peripheral module

IQ8Control M for 19" cabinet

808219

772477

Peripheral module with one additional micromodule slot

3.

Choice of the micromodules

804382.D0

Analog loop module powered loop

787531

3-relay module

784382.D0

Analog loop module

771670

Master box interface module

784842

RS 232/TTY

Serial interface module

784385

Master box interface module

787532

3-relay common fault module

787530

4-relay module

784840.10

essernet module 62,5kBd

784841.10

essernet module 500kBd

4.

Choice of the operating front* language codes available:

01 Germany

02 England

03 Italy

04 Portugal

05 Poland

06 Spain

07 Austria

08 Netherlands

09 Czech Republic

10 Russia

11 Hungary

12 Denmark

13 Sweden

14 Croatia

15 France

16 Slovakia

17 Switzerland / French

18 Romania

19 Slovenia

20 Turkey

21 Greece

22 Belgium / Flemish

23 belgium / Walloon

25 Arabic / English

27 Serbian

5.

Choice of a extension housing

(optional)

7860xx

Operating front

7861xx

Operating front w.

SZI f. 64 detector zones

7868xx

Operating front with printer

7863xx

Operating front for printer, w. take-up reel*

786000

SZI front for 192 detector zones

786100

Filler panel front, neutral

788093

19” rack mounting kit for

SZI 192 detector zones

All operating fronts, except SZI 192 detector zones are suitable for both housing types

*Requires an additional extension housing

789303

Extension housing f. additional modules

14 www.hls-austria.com

IQ8Control Panels IQ8Control M/Intelligent Addressable

FACP IQ8Control M Standard and for 19" Racks

1

808004 FACP IQ8Control M

Basic design.

The operating front must be ordered separately and is not included in the price.

Housing with rear panel and front frame for operating panel fronts, neutral front, interface board, power supply module and system software.

1

808219 FACP IQ8Control M for 19" rack

As 808004 but 19" version (7 HU) for rack installation.

The operating front must be ordered separately and is not included in the price.

FACP IQ8Control M 808004, including 19" mounting frame and flat cable for 19" installation.

1

789303 Extension housing

The standard extension housing can be used to mount additional modules, e.g. esserbus transponders.

Features

For the installation of up to 6 transponders and FO converters with installation kit

788650.

Technical Data

Ambient temperature

Storage temperature

Type of protection

Housing

Color

Weight

Dimensions

-5 °C ... 45 °C

-10 °C ... 50 °C

IP30

ABS plastic, 10% glass fiber reinforced, V -

0 gray similar to Pantone 538 approx. 5 kg

W: 450 mm H: 320 mm D: 185 mm

Housing complete with standard rear panel, neutral front and material for attaching to the existing control panel housing.

Assembling the housing parts

Take off the

4 standard covers.

Insert the

2 connecting elements.

Put the 2 housings on top of each other and push them together.

8

9

6

7

2

3

4

5

12

13

10

11

14

1.

2.

Connection between the central housing and the extension housing

3.

15

IQ8Control Panels Accessories

Operating Fronts for IQ8Control C/M

Features

alphanumerical display

Large LCD display with 8 rows x 40 characters

ESSER - front (Part No. 7860XX, 7861XX, 7863XX, 7864XX, 7865XX, 7868XX and 7869XX) is also available with the respective country specification - except the special versions. When ordering, please fill in the last two digits with the specific language code.

(Not all variants are available in all languages. Please contact your sales representative for details)

Example:

The German version of the standard operating front C/M would have the Part No. 7860-01.

For the Dutch version, the number would have to be changed to Part No. 7860-08.

Specific language code:

01 German 14 Croatian

02 English 15 French (France)

03 Italian

04 Portuguese

05 Polish

06 Spanish

16 Slovakian

17 French (Switzerland)

18 Romanian

19 Slovenian

07 German (Austria)

08 Dutch

09 Czech

10 Russian

11 Hungarian

12 Danish

13 Swedish

13 Swedish

20 Turkish

21 Greek

22 Flemish (Belgium/Dutch)

23 Walloon (Belgium/French)

25 Arabic/English

27 Serbian

52 Chinese

53 Chinese with country functionality

1

786002 Operating front, English

1

786102 Operating front with single zone indication 64, English

Technical Data

Current consumption single zone indication: per activated LED

1.5mA

16 www.hls-austria.com

IQ8Control Panels

1

786802

Features

integrated printer w/o paper take-up reel

1

786302

1

786000

1

786100

Accessories

Operating front w. printer, w/o take-up reel - ESSER, English

Technical Data

Quiescent current approx. 45 mA

Possible alternative is operating front 7863xx, printer 784892 and housing extension 789303

772445 Mounting frame

786000 SZI front for 192 detector zones, including insertable foils with country-specific version

Operating front for printer and w. take-up reel, English

The printer kit with paper take-up reel (Part No. 784892) must be ordered separately.

SZI front for 192 detector zones

Technical Data

Quiescent current

Current consumption approx. 5 mA single zone indication: per actuated LED 1.5mA

Including insertable foils with country-specific version.

Filler panel front, neutral

8

9

6

7

2

3

4

5

12

13

10

11

14

1

788093 19” rack mounting kit for SZI 192 detector zones

7 HU for upright cabinet mounting.

Technical Data

Quiescent current

Current consumption approx. 5 mA

1.5 mA per actuated LED

772445 Mounting frame

786000 SZI front for 192 detector zones, including insertable foils with country-specific version

17

IQ8Control Panels Accessories

Control Panel Modules for IQ8Control C/M

1

772479 Peripheral module

The peripheral module contains a fire brigade operating panel interface as well as an alarm transmission unit interface and three freely programmable, optionally monitored or up to 30 V DC floating common relays. The peripheral module can only be used on system terminal 1 of the control panel interface board.

Technical Data

Quiescent current approx. 15 mA

Only one (Part No. 772477/78/79) module can be plugged onto the interface board.

1

772477 Peripheral module with 1 additional micromodule slot

Same as 772479 but with one additional micromodule slot. The peripheral module can only be used on system terminal 1 of the control panel interface board.

Technical Data

Quiescent current approx. 15 mA (without micromodule)

Only one (Part No. 772477/78/79) module can be plugged onto the basic module.

1

772478

1

772476

Extension module with 1 additional micromodule slot

The extension module is plugged onto the interface board of the control panel. The extension module can only be used on system terminal 1 of the control panel interface board.

Technical Data

Quiescent current approx. 5 mA (without micromodule)

Only one (Part No. 772477/78/79) module can be plugged onto the interface board.

Extension module with 3 additional micromodule slots

The extension module is plugged onto the interface board of the control panel. This extension module can be used on plug connectors 1 and 2 of the basic control panel module.

Technical Data

Quiescent current approx. 5 mA (without micromodule)

The (Part No. 772476) extension module can only be used in the IQ8Control FACP.

18 www.hls-austria.com

IQ8Control Panels Accessories

Micromodules for IQ8Control C/M

1

784382.D0

Analog loop module

Single loop circuit module for up to 127 series 9200/IQ8 Quad intelligent fire detectors or bus devices, divisible into 127 zones.

Technical Data

Quiescent current approx. 25 mA

1

804382.D0

Analog loop module powered loop (PL)

Single loop circuit module for up to 127 bus devices, and esserbus-PLus (powered loop) devices according to the load factor. Series 9200/IQ8 Quad intelligent fire detectors and esserbus transponders (Part No. 80xxxx) or addressable sounders and powered loop base sounders.

Technical Data

Quiescent current approx. 25 mA

Powered loop compatible only with IQ8Control and FlexES.

1

784385

1

771670

1

784842

Master box interface module

Single master box interface module for activating and processing acknowledgement signals from master boxes; programmable as constant or pulsed master box activation.

Technical Data

Quiescent current approx. 15 mA

Master box interface module

Single master box interface module for activating and processing acknowledgement signals from master boxes; programmable as constant or pulsed master box activation, for potential-free triggering.

Master box interface module, 8007/8008, ESSER

Serial interface module with optional RS 232 or TTY type, for operating external devices such as external printers, printers, modems for remote diagnosis.

Technical Data

Quiescent current approx. 35 mA (RS 232) approx. 55 mA (TTY)

1

787531

1

787532

3-relay module

3-relay module with output functions which can be programmed either as NC or NO contacts, 3 x latching "monitored" relay outputs.

Technical Data

Quiescent current

Contact load relay approx. 5 mA max. 30 V DC/1 A

3-relay common fault module

3-relay module with pre-set functions such as common fault, 2 x freely programmable monitored relay outputs.

Technical Data

Quiescent current

Contact load relay approx. 15 mA max. 30 V DC/1 A

8

9

6

7

2

3

4

5

12

13

10

11

14

19

1

743212

1

743245

IQ8Control Panels

Accessories

1

784892

1

736235

1

772445

Accessories

Printer kit with paper take-up reel for IQ8Control C/M

40 characters, printer with fixed print head.

When the printer is installed in the FACP IQ8Control C, the battery case, including toroidal transformer, must be replaced by the mounting rack. The batteries and the toroidal transformer must be installed in an additional extension housing, either 789300 or 789301.

Mounting frame complete with Part No. 736234 plain text thermal printer including winder and end-ofpaper recognition.

Accessories

736235 Printer paper for printer 736234 / 784892

Printer paper for printer 736234/784892

Printer paper part no. 736234 printer with take-up reel.

Technical Data

Dimensions L: 2500 mm W: 58 mm

Mounting frame 19" IQ8Control C/M

Mounting frame with 6 HU for mounting of operating front.

1

769914

Spare key 1D009 for FACP

For upright cabinets 769163 and 769164.

Two keys.

Lever lock - type 17 for key no. 801

To lock and unlock the HMI of fire alarm panels 2001, IQ8Control C/M, 8000

M/C, 8007, 8008.

Two keys and one cylinder lock.

Spare key 801 for FACP

To lock and unlock the HMI of fire alarm panels 2001, IQ8Control C/M, 8000

M/C, 8007, 8008.

Two keys.

20 www.hls-austria.com

IQ8Control Panels

1

743248

1

769915

1

744030

1

744027

1

744028

Accessories

Lever lock - type for key no. 901

To lock and unlock the housing frame of fire alarm panels IQ8Control C/M, 8000

M/C and FlexES.

Two keys and one cylinder lock.

Spare key 901 for FACP

For fire alarm panels 2001, IQ8Control C/M, 8000 C/M, 8008 for printer and housing.

Two keys.

Dummy cover 19", 2 HU

For covering free installation space in upright cabinets and wallmount cabinets, 2 HU.

Technical Data

Material

Color sheet steel gray similar to Pantone 538

One height unit (HU) covers 44.45 mm.

Dummy cover 19", 3 HU

Same as 744030, but 3 HU.

Technical Data

Color

Dummy cover 19", 5 HU

Same as 744030, but 5 HU.

gray similar to Pantone 538

8

9

6

7

2

3

4

5

12

13

10

11

14

1

744029 Dummy cover 19", 9 HU

Same as 744030, but 9 HU.

21

IQ8Control Panels Accessories

Maintenance and Test Equipment

1

789861

Features

One software for all panels:

Start-up

Programming

Loop diagnosis

Maintenance software

1

789860.10

Programming software tools 8000

Convenient Windows programming software CD for programming the fire alarm panels belonging to series 8000 C/M, 8008, IQ8Control, FlexES Control, Gateway and extended supplementary text in ¼ VGA display.

Available Languages:

Czech, Danish, English, French, German, Hungarian, Italian, Slovakian, Spanish, Polish, Portuguese, Romanian and Russian.

For programming, the (Part No. 789862.10) field bus interface is required.

- FACP 8000 C/M, FACP 8008, IQ8Control C/M, FlexES Control or ECP 8010 as of software version V2.20

- PC/Notebook as of Windows XP, Windows 7, Windows 8

- Recommended configuration: 512 MB RAM, 500 MHz CPU

- This software is also used for the LCD panels 7851xx

Starter kit equipment PLus with programming software tools 8000

Complete package for programming the FACP 8007, 8000 C/M, 8008, Gateway, ABIGA IQ8Control and FlexES Control via PC or Notebook.

The field bus interface is used as a programming interface between the FACP and the PC/ notebook.

Furthermore, the field bus interface facilitates the direct connection of a ring bus to the convenient monitoring of a finished installation and the elimination of possible cabling mistakes.

789861 Programming software for System 8000 and IQ8Control

789862.10 Field bus and control panel interface PLus

789863 USB cable

789864 Serial connecting cable

Accessories

BME2Z002 Switched-mode power supply with cylindrical plug

789866 Programming cable for extinguishing panel 8010

Control panel

USB

Field bus interface esserbus PLus

Loop length max. 3.5 km

esserbus transponder

Application example

22 www.hls-austria.com

IQ8Control Panels

1

789862.10

1

789863

Accessories

Field bus interface PLus

Interface for the programming of the FACP 8007, 8000 C/M, 8008, gateway, ABIGA and IQ8Con trol or for the direct field-side connection of a single installed analog loop. With the optional switched-mode power supply (Part No. BME2Z002), bus-supplied alarm signaling equipment can be tested independently from the control panel via the direct connection to the field bus interface (Part

No. 789862.10).

Technical Data

Ambient temperature

Storage temperature

Type of protection

Housing

Color

Weight

Dimensions

5 °C ... 45 °C

0 °C ... 50 °C

IP 40 plastic, PS (Polystyrene) white, similar to RAL 9010 / gray, similar to RAL 7035 approx. 300 g

W: 68 mm H: 30 mm D: 135 mm

Connecting cables (Part No. 789863 and 789864) are not included in delivery.

One interface and two 6-pin plugs.

Accessories

BME2Z002 Switched-mode power supply with cylindrical plug

USB

Field bus interface

EFI-Plus

Power supply for bus supplied alarm signaling devices esserbus-PLus

Loop length max. 3,5 km

esserbus-transponder

Application example

USB cable A/B for 789862.10 field bus and panel interface

For connecting service PC/laptop with the tools 8000 field bus and panel interface.

Technical Data

Cable length 1.8 m

8

9

6

7

2

3

4

5

12

13

10

11

14

23

IQ8Control Panels

1

789864

1

BME2Z002

Accessories

Serial connecting cable for 789862.10

For connecting the field bus interface to panels 8007, 8000 C/M, 8008, Gateway, ABIGA and

IQ8Control. With 4-pin special plug for the control panel.

Technical Data

Cable length 1.9 m

Switched-mode power supply with cylindrical plug

Technical Data

Output voltage

Output current

12 V DC

1 A

1

789866 Programming cable for ECP 8010

Connecting lead for programming the extinguishing control panel 8010 to 789862.10 interface.

USB Fieldbus interface

Connecting cable, Part No. 789866 esserbus

Extinguishing panel 8010

24 www.hls-austria.com

Control Panels Extinguishing System

1

Extinguishing System 8010 - Wall Mounting

Features

1 Extinguishing area for max. 1.600 m² acc. to VdS

8 detector zones for up to 30 Series 9200 and IQ8Quad automatic detectors each (for two- detector dependency up to 25 detectors)

1 zone for manual alarm

1 zone for emergency stop

1 zone for post flooding

1 zone for extinguishing system fault

1 zone for blocking extinguishing system

1 control input for buzzer OFF

1 control input for control panel reset

8 relays, monitored or floating 30V DC/2A

3 relays, floating 30V DC/2A

2 mains voltage relays, floating 230V AC/2A

All outputs are provided with fuses

Approval: VdS

Addressable control device with integrated fire detection module for an extinguishing area in accordance with VdS 2496 and EN 12094-1. The extinguishing panel 8010 is an elec tronic control device for extinguishing systems with integrated fire detection module, compatible with Series 9200 and IQ8Quad detectors.

It is additionally provided with respective detection zones for manual alarm, post flooding and emergency stop as well as two zones for extinguishing system fault.

Complex control functions can be realised by using the 13 control groups

(relays). Up to 8 extinguishing areas on the esserbus of the fire detection system communication transponders (optional). Respectively max. 16 communication transponders per FACP 8000 C/M or IQ8Control 8000 or IQ8Control can be networked via the 808615.

Technical Data

Rated voltage

Rated frequency

Quiescent current

Rated current

Battery capacity

Ambient temperature

Storage temperature

Type of protection

Housing

Color

Weight

Dimensions

CE certificate

230 V AC

50 ... 60 Hz approx. 100 mA

0.7 A

2 x 12 V/26 Ah

-5 °C ... 45 °C

-10 °C ... 50 °C

IP 30 sheet steel approx. 1.25 mm gray (similar to RAL 7035), blue (similar to

RAL 5003) approx. 18.3 kg (without battery)

W: 488 mm H: 625 mm D: 210 mm

0786-CPD-20223

The free programming software can be downloaded from our website (downloads section).

Accessories

Indicating and operating unit 788400 (required for stand alone operation), 788615 esserbus communication transponder, control zone indicator and 788016 alarm counter.

8

9

6

7

2

3

4

5

12

13

10

11

14

1

788012.40

esserbus

Loop length max. 3.5 km

Extinguishing panel 8010

Monitoring

Module

Extinguishing Agent

Tank

Valve

Selector

Valve

IQ8Control

Application example

Extinguishing panel 8010, Series 4, w/o operating unit

Corresponding indication and operating panel available in different languages, which can be found in "Options for Extinguishing Control Panels 8010 Wall Mounting".

1

788013.40

1

788013.40.RU

Extinguishing panel 8010, Series 4, with operating unit, German

Same as 788012.40, but with operating unit (Part No. 788400).

Extinguishing panel 8010, Series 4, with operating unit, Russian

Same as 788013.40, but Russian version.

25

Control Panels Extinguishing System

Extinguishing Control Panel 8010 - Rack Mounting, 3HU

Features

8 detector zones for up to 30 series 9200 or

IQ8Quad automatic fire detectors per detector zone (max. 25 detectors in two-detector dependency)

1 detector zone manual alarm

1 detector zone emergency stop

1 detector zone post flooding

1 detector zone blocked extinguishing system

1 control input buzzer off

1 control input reset control panel

8 monitorable relays 30 V DC /2A

3 floating relays 30 V DC /2A

2 relays for mains voltage 230 V (connection at the back)

Each output is protected by fuses

Electronically controlled ventilation fan

Operating unit:

13 LED-indication with inscription fields for indicating activated outputs

Mechanical alarm counter

LED display to indicate the detector zone status

LED collective display

Keypad can be intuitively handled

Key operated switch for keypad activation

Emergency current supply 2 batteries 12 V/12

Ah (not supplied as standard)

Addressable EN 12094-1 extinguishing panel for extinguishing zone control in compliance with

VdS 2496, with integrated fire detection unit and optional convenient operating and indicating panel.

The slide-in concept enables space-saving, ergonomic integration into a 19" housing for installation heights of only 3 height units (13.34 cm). Peripherals are connected at the back of the housing via plug-in cable connections to accessible connection terminals, allowing convenient installation within the housing before the insert is integrated. With the communication transponder (Part No.

808615), a maximum of eight extinguishing control panels can be networked on one esserbus or powered loop in fire alarm systems FACP 8000, Q8Control or FlexES Control. Using the programming interface plugged to the front, the extinguishing panel settings can be adjusted to the specific requirements and information can be transferred for visualizing the master fire alarm system via the loop.

Technical Data

Rated voltage

Rated frequency

Rated current

Quiescent current

Battery capacity

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Dimensions

Declaration of Performance

230 V AC

50 ... 60 Hz

0.7 A approx. 100 mA

2 x 12 V DC/12 Ah

-5 °C ... 45 °C

-10 °C ... 50 °C

< 95 % (non-condensing)

IP 30 sheet steel

W: 483 mm H: 132 mm D: 403 mm (without grip)

DoP-20223130701

The use of heavy duty rails from the respective cabinet manufacturer is recommended for installation in 19" upright cabinets.

Special

Connection module incl. connection cable

(Part No. 788653 or 788654)

Fire alarm and extinguishing panel

No.1 to No.5

Power supply 230 V

Installation of multiple extinguishing panels in one upright cabinet

26 www.hls-austria.com

Control Panels

1

788014.40

1

788014.40.GB

788014.40.PL

788014.40.CZ

788014.40.RO

Extinguishing System

Extinguishing control panel, Series 4, German

Approval: VdS

Extinguishing panel as per 12094 for extinguishing zone control in complaince with VdS 2496, with integrated fire detection unit and optional convenient operating and indicating panel. The slide-in concept enables space-saving, ergonomic integration into a 19-inch housing for installation heights of only 3 height units (13.35 cm). Peripherals are connected at the back of the housing via plug-in cable connections to accessible connection terminals, allowing convenient installation within the housing before the insert is integrated. With the communication transponder (Part No. 808615), a maximum of eight extinguishing control panels can be networked on one esserbus or powered loop in Fire Alarm Systems FACP 8000, IQ8Control or FlexES Control. Via the programming interface plugged to the front, the extinguishing panel settings can be adjusted to the specific requirements and inform ation can be transferred for visulaising to the master fire alarm system via the loop.

Accessories

788653 Terminal card for panel 8010 in 19" technology (3 HU), 1 m

788654 Terminal card for panel 8010 in 19" technology (3 HU), 2 m

Extinguishing control panel, Series 4, English

Same as 788014.40, but English version.

Extinguishing control panel 8010 Series 4 with operating unit, Polish

As.40, but Polish version.

Extinguishing control panel 8010 Series 4 with operating unit, Czech

As 788014.40, but Czech version.

Extinguishing control panel 8010 Series 4 with operating unit, Romanian

As 788014.40, but Romanian version.

8

9

6

7

2

3

4

5

12

13

10

11

14

27

788401

788402

788404

788406

1

788016

Control Panels Extinguishing System

Accessories for Extinguishing Control Panels 8010 in 19" Racks

1

788653 Terminal card for panel 8010 in 19" rack, 1 m

Length of plug-in connection cables: 1 m

2 x 50-pin connection cable 1m D-Sub50

1 x Terminal card for top hat rail or C-rail mounting with D-Sub pin connectors

1 x Terminal card for top hat rail or C-rail mounting with D-Sub multi-point connectors

788654

788400

Terminal card for panel 8010 in 19" rack, 2 m

As 788653, but plug-in connection cable with 2 m length.

Indicating and operating panel for ECP 8010, German

Integrated detector zone indication in German. Can be set to show status indication for control outputs. LED for relevant extinguishing system function indication.

1

788023.10

Indicating and operating panel for ECP 8010, English

Same as 788400, but English.

Indicating and operating panel for ECP 8010, Polish

As 788400, but Polish.

Indicating and operating panel for ECP 8010, Czech

As 788400 but Czech.

Indicating and operating panel for ECP 8010, Romanian

As 788400 but Romanian.

Option control group indication and alarm counter for ECP 8010, German

Additional LEDs for indicating activated control outputs and mechanical alarm counter. The indicators are mounted to the second recess of the 8010 releasing control equipment. The PCB connection cable is connected to the (Part No. 788400) indicating and operating panel.

Foil with German description

Multiple-sector interface in housing

Approval: VdS

For the formation of multiple-sector control, up to four extinguishing panels 8010 can be networked via a multiple-sector interfaces. The cascading of a max. of 3 multiple-sector interface is possible for multi-sector control of a max. of 10 extinguishing panels 8010.

Technical Data

Declaration of Performance DoP-21170130701

28 www.hls-austria.com

Power Supplies

Power Supply Units

Voltage Converters

Batteries (Rechargeable)

Accessories

10

11

30-32

33

34

34

12

13

14

8

9

6

7

2

3

4

5

29

Power Supplies Power Supply Units

1

Power Supply - Housing Version

Approval: VdS, CNBOP

The power supply ZSP135-DR is dedicated to work in fire detection and building automa tion systems. It is a source of guaranteed 24V voltage. It is manufactured as a wall box with a lock. It has a space inside to mount two batteries. The controller protects the internal battery bank against too low discharge by means of the built-in disconnect device. The power supply complies with the norm EN 54 and EN 12101-10.

Application:- components of fire alarm systems

- actuators of smoke extraction systems and fire and smoke dampers

- fire alarm detector and sounders

- devices of industrial automation

Features

light indication of the state of the power supply

floating mode with temperature compensation

equalize charging of the battery with the charging

current limitation detection of low and high voltage of the battery detection of a battery circuit break

electronic low voltage disconnect of the battery

monitoring of output fuses

continuous testing of the rectifier’s operation

monitoring of the internal temperature

visual and remote indication of alarm

Technical Data

Rated voltage

Output voltage

Efficiency

Cooling

Ambient temperature

Type of protection

230 V AC

24 V DC

> 80 %

Convection

-25 °C ... 55 °C

IP43

960000.10.GB

960001.10.GB

External power supply 2 A / 24 V DC 17Ah EN 54-4

Batteries for power supplies ZSP135-DR should be ordered separately.

Technical Data

Output current

Rated Output Current

Battery capacity

Weight

Dimensions max.2 A

1 A max. 17 Ah approx. 18 kg (incl. batteries)

W: 390 mm H: 350 mm D: 90 mm

External power supply 3 A / 24 V DC 17Ah EN54-4

Batteries for power supplies ZSP135-DR should be ordered separately.

Technical Data

Output current

Rated Output Current

Battery capacity

Weight

Dimensions max.3 A

2 A max. 17 Ah approx. 18 kg (incl. batteries)

W: 390 mm H: 350 mm D: 90 mm

960002.10.GB

External power supply 3 A / 24 V DC 28Ah EN 54-4

Batteries for power supplies ZSP135-DR should be ordered separately.

Technical Data

Output current

Rated Output Current

Battery capacity

Weight

Dimensions max.3 A

1.5 A max. 28 Ah approx. 28.3 kg (incl. batteries)

W: 390 mm H: 350 mm D: 140 mm

30 www.hls-austria.com

Power Supplies

960003.10.GB

960004.10.GB

960005.10.GB

960006.10.GB

960007.10.GB

960008.10.GB

Power Supply Units

External power supply 5 A / 24 V DC 17Ah EN 54-4

Batteries for power supplies ZSP135-DR should be ordered separately.

Technical Data

Output current

Rated Output Current

Battery capacity

Weight

Dimensions max.5 A

4 A max. 17 Ah approx. 18 kg (incl. batteries)

W: 390 mm H: 350 mm D: 90 mm

External power supply 5 A / 24 V DC 28Ah EN 54-4

Batteries for power supplies ZSP135-DR should be ordered separately.

Technical Data

Output current

Rated Output Current

Battery capacity

Weight

Dimensions max.5 A

3.5 A max. 28 Ah approx. 28.3 kg (incl. batteries)

W: 390 mm H: 350 mm D: 140 mm

External power supply 5 A / 24 V DC 40Ah EN 54-4

Batteries for power supplies ZSP135-DR should be ordered separately.

Technical Data

Output current

Rated Output Current

Battery capacity

Weight

Dimensions max.5 A

3 A max. 40 Ah approx. 42.3 kg (incl. batteries)

W: 450 mm H: 350 mm D: 180 mm

External power supply 7 A / 24 V DC 28Ah EN 54-4

Batteries for power supplies ZSP135-DR should be ordered separately.

Technical Data

Output current

Rated Output Current

Battery capacity

Weight

Dimensions max.7 A

5.5 A max. 28 Ah approx. 28.3 kg (incl. batteries)

W: 390 mm H: 350 mm D: 140 mm

External power supply 7 A / 24 V DC 40Ah EN 54-4

Batteries for power supplies ZSP135-DR should be ordered separately.

Technical Data

Output current

Rated Output Current

Battery capacity

Weight

Dimensions max.7 A

5 A max. 40 Ah approx. 42.3 kg (incl. batteries)

W: 450 mm H: 350 mm D: 180 mm

External power supply 7 A / 24 V DC 17Ah EN 54-4

Batteries for power supplies ZSP135-DR should be ordered separately.

Technical Data

Output current

Rated Output Current

Battery capacity

Weight

Dimensions max.7 A

5 A max. 17Ah approx. 42.3 kg (incl. batteries)

W: 450 mm H: 350 mm D: 180 mm

8

9

6

7

2

3

4

5

12

13

10

11

14

31

Power Supplies Power Supply Units

Features

Reversible output voltage 12 V DC or 24 V DC

Simple integration into esserbus/esserbus-Plus

Internal service LED displays

Four floating relay outputs

Monitoring of mains voltage with selectable delay time

Individual battery monitoring for emergency power operation

Switchable ground fault monitoring

Front door with cover contact

in compliance with EN 54-4/A2

for use in voice alarms to supply recessed components, such as at fiber optic recessed callstations

External power supply DCU 2403

Approval: G 210052

External power supply in a compact metal housing for up to two 12 V/ 24 Ah batteries. This power supply facilitates an uninterruptable supply of power. Integration into the esserbus/esserbus-Plus optional via optional adapter card (Part No. 805684.10) and esserbus Transponder (Part No.

808623). Four floating relay outputs are available for the transmission of disturbances (power failure, ground fault, battery failure and collective fault). External LED display for operation and collective fault on the lockable front door, internal LEDs for detailed recognition of emergency power operation, individual monitoring of battery failure and ground fault.

Technical Data

Rated voltage

Rated frequency

Output voltage

Battery capacity

Output current

Contact load relay

Ambient temperature

Storage temperature

Connection terminal

Housing

Type of protection

Air humidity

Color

Weight

Dimensions

230 V AC

50 ... 60 Hz

12 V DC / 24 V DC; ± 1 % (temperature controlled) max. 48 Ah @ 12 V DC / max. 24 Ah @ 24 V DC

6 A @ 12 V DC / 3 A @ 24 V DC max. 125 V / 1,5 A / 60 VA

-5 °C ... 40 °C

-20 °C ... 45 °C max. 2,5 mm² sheet steel

IP 30

< 95 % (non condensing) gray, similar to RAL 7035 approx. 23 kg incl. batteries each 12 V DC / 24 Ah

W: 310 mm H: 410 mm D: 211 mm

Batteries used in the power supply must be tested and VdS approved. Batteries of the same age from the same manufacturer coming from the same production batch must be used when connecting batteries in parallel.

Pre-installed connector cable for 12 V / 24 Ah SB-type battery (Part No. 018006)

Housing lock with key

Device accessory kit contains: dummy cover, jumper bar for standby terminal, device fuses, jumper for setup of output voltage

Accessories

805684.10 Adapter card for DCU 2402

808623 esserbus alarm transponder

1

781335

Features

Each output is separately fused

DC/DC converter 12 V/24 V DC

Approval: VdS

This converter generates 24 V as power supply for special detectors. The input voltage of 12 V is taken from the FACP or an external 12 V power supply. Mounted inside the FACP (mounting kit

Part No. 788605), this module can supply up to 4 special detectors with a maximum current of 125 mA each or 1 special detector with 500 mA. This module can be integrated in cabinets (Part No.

120240, 788600 and 788601). Please pay attention to the primary current consumption (12 V) in case of mains failure.

Technical Data

Operating voltage

Output voltage

Output current

Ambient temperature

Storage temperature

Air humidity

Type of protection

Weight

Dimensions

Declaration of Performance

9 ... 15 V DC

24 V DC ± 10 % max. 500 mA (4 x 125 mA)

-10 °C ... 50 °C

-15 °C ... 55 °C

< 95 % (non-condensing)

IP 40 (housing) approx. 150 g

W: 65 mm H: 72 mm D: 20 mm

DoP-20616130701

32 www.hls-austria.com

Power Supplies Voltage Converters

1

781336

Features

Direct current potentials are electrically isolated

Voltage interface, for instance, for operating transponders connected to an extinguishing control panel 8010 Series 3 configured for 12 V

DC operation

Suitable for max 1.5 mm² connection terminals

Short circuit resilient

This converter generates 12 V as "electrically isolated" power supply for one special detector. The input voltage of 12 V is taken from the FACP or an external power supply. This module can be integrated in cabinets (Part No. 120240, 788600, 788601 and 788603.10). Please pay attention to the primary current consumption (12 V) in case of mains failure.

Technical Data

Operating voltage

Output voltage

Output current

Ambient temperature

Storage temperature

Air humidity

Type of protection

Weight

Dimensions

Declaration of Performance

10 ... 28 V DC

12 V DC ± 10 % max. 800 mA

-10 °C ... 50 °C

-15 °C ... 55 °C

< 95 % (non-condensing)

IP 40 (housing) approx. 70 g

W: 65 mm H: 72 mm D: 20 mm

DoP-20617130701

The module can also be used in explosion endangered zones for the galvanic separation of the esserbus voltage supply.

1

781337

DC/DC converter output voltage 12 V DC

Approval: VdS

DC/DC converter output voltage 24 V DC

Approval: VdS

Features

Direct current potentials are electrically isolated

Suitable for max 1.5 mm² connection terminals

Short circuit resilient

This converter generates 24 V as power supply for one special detector. The input voltage of 12 V is taken from the FACP or an external power supply. This module can be integrated in cabinets

(Part No. 120240, 788600, 788601 and 788603.10). Please pay attention to the primary current consumption (12 V) in case of mains failure.

Technical Data

Operating voltage

Output voltage

Output current

Ambient temperature

Storage temperature

Air humidity

Type of protection

Weight

Dimensions

Declaration of Performance

10 ... 28 V DC

24 V DC ± 10 % max. 400 mA

-10 °C ... 50 °C

-15 °C ... 55 °C

< 95 % (non-condensing)

IP 40 (housing) approx. 70 g

W: 65 mm H: 72 mm D: 20 mm

DoP-20617130701

8

9

6

7

2

3

4

5

12

13

10

11

14

33

Power Supplies

Power Supply - Accessories

The listed lead storage battery are maintenance-free, sealed electrolyte batteries. They are relatively position-independent (should not be charged upside-down), deep-cycled, cycle-resistant and long-lasting (4 to 5 years). Charge voltage at an ambient temperature of +20°C: 12 V DC (6 x 2.3

V per cell) 13.8 volts, this can be subject to tolerances.

Technical data sheets are available on demand.

The batteries comply with the VDE 0833-1 regulations for hazard alarm systems and are VdS approved.

018001 Battery 12 V DC/1.2 Ah capacity

018002

018004

018011

018006

018007

018009

Battery 12 V DC/2.1 Ah capacity

Battery 12 V DC/7 Ah capacity

Battery 12 V DC/12 Ah capacity

2 x Fast-on adapters from 6.3 mm to 4.3 mm

Battery 12V DC/24Ah capacity

2x Fast-On Adapter from M6 by 6.3mm each 2x M5 hex bolt/washers and snap ring

Battery 12 V DC/17 Ah capacity

2 x Fast-on adapters from M6 to 6.3mm each 2 x M5 hexagon head cap screws, washers and snap rings.

Battery 12 V DC/38 Ah capacity

2 x Fast-on adapters from M6 to 6.3mm each 2 x M6 hexagon head cap screws, 4 x washers and snap rings.

Power Supply - Accessories

1

805597 3.6 V Lithium battery

4 Lithium batteries for use in wireless detector base (Part No. 805593.10), wireless gateway for detectors (Part No. 805594.10) and wireless universal interface (Part No. 805601.10/805602.10).

4 pcs

34 www.hls-austria.com

Displays and Operating Units

LED Indicator Panel

LCD Indicator Panel

System 3000

8

9

6

7

2

3

4

5

10

11

36

37

38-40

12

13

14

35

Displays and Operating Units

LED Indicator Panel

1

764790

1

804791

System IQ8Control

Standard LED remote indicator panel

Approval: VdS

Additional indicator for up to 32 alarm, trouble or collective signals. Connection via an integrated

32-pin terminal strip. The indicator is controlled via relay contacts or semiconductor outputs with positive-guided contacts in the hazard detection system. With key for lamp testing, integrated buzzer and easy-to-maintain terminal card. Elegant plastic housing for surface mounting.

Technical Data

Operating voltage

Quiescent current @ 12 V DC

Alarm current @ 12 V DC

Display

Connection terminal

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

10 ... 15 V DC approx. 1 mA approx. 380 mA (incl. 32 LED & buzzer)

32 LED, red max. 1.5mm²

-5 °C ... 50 °C

-25 °C ... 75 °C

< 95 % (non-condensing)

IP 40

ABS plastic white (similar to RAL 9003), front blue (similar to RAL

5003) approx. 1000 g

W: 270 mm H: 221 mm D: 71 mm

This indicator panel is not suitable for application as an initial warning device for the fire brigade.

Loop LED remote indicator panel for 32 messages

Approval: VdS

Same as 764790, but with integrated and wired esserbus transponder 32 LEDs for operation as a remote indicating panel for the esserbus. For connection to the esserbus and powered loop in fire alarm systems 8000, IQ8Control or FlexES Control.

Technical Data

Operating voltage

Quiescent current @ 12 V DC

Alarm current @ 12 V DC

Display

Connection terminal

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

10 ... 15 V DC approx. 1 mA approx. 380 mA (incl. 32 LED & buzzer)

32 LED, red

1.5 mm²

-5 °C ... 50 °C

-25 °C ... 75 °C

< 95 % (non-condensing)

IP 40

ABS plastic white (similar to RAL 9003), front blue (similar to RAL

5003) approx. 1000 g

W: 270 mm H: 221 mm D: 71 mm

Isolator (Part No. 788612) not included, please order separately.

This indicator panel is not suitable for application as an initial warning device for the fire brigade.

36 www.hls-austria.com

Displays and Operating Units System IQ8Control

LCD Indicator Panel

1

785101 LCD indicator panel, English

The LCD indicator panel is used as an add-on device for the remote display of FACP status information of the System 8000 and IQ8Control relating to detectors and detector zones.

Event messages are displayed via LED collective indicators and on the 2-line LCD display with the associated detector zone number and a programmable additional text. Each message is signaled via the built-in buzzer. The buzzer can be acknowledged by pressing a button.

Up to 31 LCD indicator panels can be operated on an RS 485 bus, either directly on the RS 485 interface of the basic card of FACP 8007/8000C/8000M/IQ8Control or using a common RS 485 converter on another serial interface (e.g. RS 232).

The additional texts are programmed using the tools 8000 software package and a service PC connected via the Part No. 789862.10 programming interface.

Features

Display of zone and detector status information of the FACP with additional text

Event memory for 200 messages

Free programming up to a max. of 4,000 additional texts, each with 2 x 20 characters

Sequential message interrogation via scroll keys

Monitoring of the serial interface

Internal buzzer, can be switched off via key

Function test of the display elements

Potential-free relay

Technical Data

Operating voltage

Quiescent current

Alarm current @ 12 V DC

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

9 ... 30 V DC approx. 30 mA approx. 60 mA

0 °C ... 45 °C

0 °C ... 50 °C

< 95 % (non-condensing)

IP 30 plastic (ABS) white, similar RAL 9001 approx. 750 g

W: 206 mm H: 177 mm D: 48.5 mm

785107

785109

785113

LCD indicator panel, Polish

As 785101, but Polish version.

LCD indicator panel, Czech

As 785101, but Czech version.

LCD indicator panel, Hungarian

As 785101, but Hungarian version.

8

9

6

7

2

3

4

5

12

13

10

11

14

37

Displays and Operating Units System 3000

Fire Brigade Operating Panels

1

784710

784710.PL

784710.CZ

Fire brigade operating panel, German

Approval: VdS

The fire department operating unit (in accordance with DIN 14661) is an additional device for fire detection systems that contains transmission units to the fire department. The essential display and operating elements of the fire alarm control panel are located on the fire department operating unit (FDOU). The fire fighters can handle all necessary alarm measures via the FDOU – so they do not need any special training on the control panel.

Technical Data

Operating voltage

Quiescent current @ 12 V DC

Alarm current @ 12 V DC

Ambient temperature

Storage temperature

Type of protection

Housing

Color

Weight

Dimensions

10.5 ... 30 V DC approx. 18 mA approx. 75 mA

0 °C ... 50

-10 °C ... 60 °C

IP 30 sheet steel gray, similar toRAL 7032 approx. 3.4 kg

W: 255 mm H: 185 mm D: 58 mm

This fire department operating unit is not compatible with any FlexES control!

The fire brigade operating panel is supplied without locking cylinder (DIN 18252). It should be acquired in accordance with the guidelines provided by the regional fire brigade.

Fire brigade operating panel, Polish

As 784710, but Polish version.

Fire brigade operating panel, Czech

As 784710, but Czech version.

38 www.hls-austria.com

Displays and Operating Units System 3000

LCD Indicator Panels

1

784743.CZ

ESPA 4.4.4

RS 232 telecom device or pager

784743.PL

ser.- IF

UB

FACP

Fire department indicating panel FAT3000, Czech

Approval: VdS

Microprocessor-controlled fire department indicating panel in compliance with DIN 14662 as an additional indicator for fire alarm panels. Serial connection to the fire alarm panel via variable interfaces TTY, DUAL RS 485, RS232 and ESPA 4.4.4 (on board), conventional and redundant activation, plain text display with 4 x 20 characters, collective LED indication (alarm, trouble, deactivation). Simple handling with 4 buttons (buzzer OFF/level/scroll buttons). Additional text (> 4000 texts) can be programmed using a PC with serial interface connection, event memory, redundancy via loop structure for up to 16 FAT, power supply and signaling pathway are monitored to prevent short or open circuits, full functional range during breakdown of one circuit. The ESPA interface enables direct connection of telecom munication and paging systems.

Technical Data

Operating voltage

Quiescent current @ 12 V DC

Alarm current @ 12 V DC

Ambient temperature

Storage temperature

Type of protection

Housing

Color

Weight

Dimensions

8 ... 30 V DC approx. 65 mA approx. 125 mA

-5 °C ... 40 °C

-10 °C ... 60 °C

IP 30 sheet steel gray, similar to RAL 7032 approx. 3.5 kg

W: 255 mm H: 185 mm D: 58 mm

The module can only be used when combined with a System 8000 or IQ8Control Fire Alarm Control

Panel.

Programming software "FatProgWin" is included.

Fire department indicating panel FAT3000, Polish

As 784743, but Polish version.

Indicator and Operating Panels in Metal Cabinets

1

784725.PL

FB information and operating system, DIN A4, Polish

Sheet steel housing with two doors for surface mount or flush mount installation with central door opening for both door. The right-hand housing door can be individually opened by means of a built-in CL1 lock. Door opening through fire brigade lock (suitable for half profile cylinder installation). In the left-hand door of the housing, a 784743 fire service indicator panel and a fire service operating panel 784710 are installed. The housing is designed for holding a transmission unit or a manual call point. The fire service indicator panel is actuated via the serial interface in the control panel. The fire service operating panel is connected to the control panel interface. A maximum of 2 x 100 DIN A4 / horizonal layout fire brigade route maps can be integrated.

Technical Data

Operating voltage

Quiescent current @ 12 V DC

Alarm current @ 12 V DC

Ambient temperature

Storage temperature

Type of protection

Housing

Color

Weight

Dimensions

10 ... 30 V DC approx. 50 mA approx. 180 mA

-5 °C ... 40 °C

-10 °C ... 60 °C

IP30 sheet steel red, similar to RAL 3000 approx. 15 kg

W: 710 mm H: 560 mm D: 100 mm

Only in combination with the System 8000, IQ8Control fire detection panels. For redundant operation, redundancy module ADP-N3E (Part No. 784744) is required.

Double-door sheet steel housing

Fire service indicating panel 784743

Fire service operating panel 784710

8

9

6

7

2

3

4

5

12

13

10

11

14

39

Displays and Operating Units

Adapter Modules

1

784744

Features

Input: TTY from the internal FACP interface

Output: DUAL RS 485 to the FAT interface

1

784753

System 3000

Adapter module ADP-N3E

Microprocessor-controlled module for installation (mounting rail) in System 8000 or IQ8Control fire alarm panels. In compliance with DIN 14675, the TTY interface can be used for redundant transmission when the adaptor is connected and when the fire department indicating panel FAT3000 is used for initially informing the fire department. Additional text (> 4,000 texts) can be programmed using a PC with serial interface connection.

Technical Data

Operating voltage

Quiescent current @ 12 V DC

Contact load relay

Connection terminal

Ambient temperature

Storage temperature

Weight

Dimensions

8 ... 30 V DC approx. 55 mA

30 V DC / 1 A max 2 x 0.8 mm²

-5 °C ... 40 °C

-10 °C ... 60 °C approx. 100 g

W: 80 mm H: 150 mm D: 30 mm

The top hat rail module (part no. 788652) and the module housing for snap-on mounting rail (part no.

788603.10) can be used for installation. The interface is compatible with FAT3000 (784743). Power is supplied by the fire alarm panel or an external power supply unit. Maximum data line length: 800 m.

Adapter module ADP-PRS-422

Additional module for connecting a paging system to a series 8000/IQ8Control fire alarm system with ADP-N3E. To connect the paging system via an electrically isolated RS 232 interface, an

ADP-PRS-422 is used.

Technical Data

Operating voltage

Quiescent current @ 12 V DC

Dimensions

RS 422, max.

line length

1.000 m

8 ... 30 V DC approx. 5 mA

W: 100 mm H: 80 mm D: 20 mm

RS 232, max.

line length

15 m

Nurse call system

FACP with adapter PCB

Part No. 784744

Connection example

Adapter module ADP- PRS-422

Part No. 784753

40 www.hls-austria.com

Connection example

Network

essernet

8

9

6

7

2

3

4

5

10

11

42-46

12

13

14

41

Network essernet

The essernet is a short circuit and open circuit resistant 2-wire backbone for networking fire detection panels from the ESSER product range. The essernet permits both hierarchy-restricted and hierarchy-free programming of panels. The essernet has been tested and approved by the VdS.

The hardware components are listed in the respective equipment approvals of the fire detection panels.

Up to 31 panels can be networked with each other in a ring loop. Superior functions and functions covering different panels can be programmed. The status of the entire system can be read off on anything from one to all panels as desired. Likewise, the system can be operated entirely from one panel.

Networking can be carried out via a simple telecommunication cable, e.g. IY-ST-Y 2 x 0.8 mm, with

784840.10 or using a data cable, e.g. IBM type 1 as well as CAT5 cable, with 784841.10. With the essernet repeaters, cable distances of up to 3000 m between two panels are possible. An optical waveguide fibre is possible with the converters, which are listed below.

Third-party or management systems (e.g. WINMAGplus) can be connected via the serial essernet interface.

3,5 km

Segment lenght max. 1 km

Application example

42 www.hls-austria.com

Network

1

784840.10

1

784841.10

1

784865

1

784843 essernet essernet

®

module, 62.5 kBd for IQ8Control

Network interface module for max. 16 network participants.

Topology: Ring structure, interruption and short-circuit tolerance

Technical Data

Quiescent current @ 12 V DC

Cable

Cable length per segment approx. 150 mA telecommunications cable I Y (St) Y n x 2 x 0.8 mm

1000 m (max. between 2 users)

essernet

®

module, 500 kBd for IQ8Control

Network interface module such as essernet module Item no. 784840.10, however for max. 31 network participants.

Technical Data

Quiescent current @ 12 V DC

Cable

Cable length per segment approx. 150 mA

IBM type 1,2,6 or similar (e.g. BELDEN 1634A)

1000 m (IBM Typ1 max. between 2 users), max. 400 m when Cat3 cable or higher

essernet repeater, 62.5 kBd

Approval: VdS

The essernet repeater increases the maximum distance between two FACP in the essernet by up to 1000 m. Standard telephone cables can be used as connection leads. Two repeaters can be operated in line.

Technical Data

Operating voltage

Current consumption @ 12 V DC

Ambient temperature

Storage temperature

Cable

Type of protection

Housing

Air humidity

Color

Weight

Dimensions

Declaration of Performance

8 ... 18 V DC approx. 100 mA

-10 °C ... 70 °C

-20 °C ... 80 °C telecommunications cable IY(St)Y n x 2 x 0.8 mm

IP65 die-cast aluminum

< 95 % (non-condensing) gray approx. 520 g

W: 125 mm H: 60 mm D: 80 mm

DoP-20619130701

essernet repeater, 500 kBd

Approval: VdS

As 784865, but with 500 kBd baud rate. IBM type 1, type 2 or type 6 cables can be used as connection leads or similar.

10

11

12

13

14

8

9

6

7

2

3

4

5

43

Network essernet

1

784766 FO converter for essernet, single-mode

The fiber optic converter for essernet, required to connect two single-mode fibers, must be installed directly into the control panel’s housing. This is done by mounting it directly on the top-hat rail without any further mounting fixtures.

Prefabricated connecting cable approx. 1.5 m included for connection to the essernet module in the FACP.

The device should be installed as close as possible to the FACP and the connecting cable should not be extended!

Features

Two single-mode fibers are required per network section.

The fibers must be connected directly without interruption (e.g. no connection via multiplexers permitted)

Fiber type G9/125 μm

max. permitted attenuation of 17 dB corresponds to a length of approx. 20 km or

Fiber type G10/125 μm

max. permitted attenuation of 17 dB corresponds to a length of approx. 20 km

Technical Data

Operating voltage

Current consumption @ 12 V DC

Current consumption @ 24 V DC

Ambient temperature

Storage temperature

Wavelength

FO-Connector

Type of protection

Housing

Installation

Air humidity

Weight

Dimensions

9 ... 30 V DC approx. 70 mA approx. 35 mA

-5 °C ... 50 °C

-10 °C ... 55 °C

1300 nm

F-ST

IP40 aluminum mounting rail

< 95 % (non-condensing) approx. 200 g

W: 55 mm H: 24 mm D: 105 mm

Max. optical loss per FO-segment (20 km):

E9/125 µm: 17 dB, E10/125 µm: 17 dB

Accessories

788602 Top hat rail

788652 Mounting rail for FACP 8000 and IQ8Control

1

784855

Features

Serial data rate 19.2 kBd

RS 485 interface on-board for a max. length of

1,000 m

SEI serial essernet interface EDP, unidirectional

The serial essernet interface can be used as a gateway to link remote computers that support the

ESSER data protocol (EDP). The EDP version (unidirectional) is only provided with information from the essernet, remote control is not possible.The unit includes a slot for an essernet module and is therefore a fully functional unit within the short circuit and open circuit resistant essernet.

Technical Data

Operating voltage

Current consumption @ 12 V DC

Current consumption @ 24 V DC

Ambient temperature

Storage temperature

Air humidity

10.5 ... 28 V DC approx. 60 mA approx. 30 mA

-5 °C ... 50 °C

-10 °C ... 50 °C

< 95 % (non-condensing)

The essernet micromodule and the interface module are not included and must be ordered separately in accordance with the required essernet type and the serial transmission standard.

Accessories

788606 Housing kit

772386 Interface-module RS 232/V 24

772387 Interface-module TTY/CL 20 mA

784840.10 essernet micromodule (62.5 kBd)

784841.10 essernet micromodule (500 kBd)

44 www.hls-austria.com

Network

1

784856 essernet

SEI serial essernet interface EDP, bidirectional

as 784855, but bidirectional with remote control options e.g. for the connection to a Building

Management System (BMS)

2

1

784859

Features

RS 485 interface on board for a max. length of

1,000 m

FACP remote SEI serial essernet interface

The serial essernet interface is a router with internal RS 485 interface for interfacing an 8000,

IQ8Control or FlexES Control fire alarm panel over relatively large distances e.g. subnetworks.

Information from the connected fire alarm panel is received via a router/router link and made available in the host essernet. The first SEI is connected as Master and the second SEI as Slave.

It has a slot for an essernet loop module and is thus an integral device in the short circuit and open circuit resistant essernet. For remote function, you can use the integrated RS 485 interface.

The essernet micromodule and the interface module are not included and must be ordered separately, depending on the type of essernet and the serial transmission mode.

770432 SEI setup

Accessories

788606 Housing kit

772386 Interface-module RS 232/V 24

772387 Interface-module TTY/CL 20 mA

784840.10 essernet micromodule (62.5 kBd)

784841.10 essernet micromodule (500 kBd)

5

3

4

6

7

8

9

10

11

12

13

14

45

Network

Accessories

1

788606

1

772386

1

772387 essernet

Housing for SEI

Housing for the serial essernet interface (SEI).

Technical Data

Type of protection

Housing

Color

Dimensions

IP31

ABS plastic white similar to RAL 9003, front blue similar to RAL

5003

W: 270 mm H: 221 mm D: 71 mm

Interface-Module RS232 / V24

For the serial essernet interface for a length up to 15 m.

Interface module TTY/CL 20 mA

For the serial essernet interface for a length up to 1,000 m.

1

013405.20

Features

Transmission with RS232 max. length 15 m and with

RS485 max. length 1,000 m

Serial interface: RS232, RS422 or RS485 (2- and

4-wire), configurable via software

Transmission speed: 300 bauds to max. 230 kBaud

configurable via software

Serial connection: D-Sub 25, socket

Ethernet interface: 10Base-T/100Base-TX

Transmission speed: 10/100/auto Mbit, configur able via software

Mode of transmission: half- /full-duplex or auto matic,

configurable via software

Network access: RJ45

Supported protocol: ARP, UDP, TCP, ICMP, Telenet,

TFTP, AutoIP, DHCP, HTTP, SNMP, TCP, UDP and

Telnet, TFTP

Hardware option TCP/IP converter, Ethernet RS232 / RS485

This hardware option is used to connect a remotely a stand-alone FACP or an essernet FACP network essernet via a (for example) company-wide Ethernet LAN to a MBS Management Building

System e.g. WINMAG plus control center via TCP/IP. This allows the device to be used as a protocol converter between the SEI contained on the essernet and the WINMAGplus control center available in the Ethernet LAN.

Technical Data

Operating voltage

Ambient temperature

Storage temperature

Air humidity

Housing

Weight

Power consumption

Dimensions

12 ... 48 V DC

0 °C ... 55 °C

-20 °C ... 75 °C

< 95 % (non condensing) metal approx. 340 g

1.5 W

W: 52 mm H: 80 mm D: 22 mm (housing)

W: 75.2 mm H: 80 mm D: 22 mm (with tabs)

System requirements for operation and software configuration: Windows ® 2000 / XP.

Bidirectional or unidirectional data transfer depends on the SEI used, thus serial essernet interface EDP unidirectional Part No. 784855 or bidirectional Part No. 784856. Up to 10 TCP/IP converters can be connected per PC (Personal Computer).

46 www.hls-austria.com

Hazard Management System

WINMAGplus

WINMAGLite

Difference WINMAGLite vs. WINMAGplus

8

9

6

7

10

11

48-56

57

58

12

13

14

2

3

4

5

47

Management Systems WINMAGplus

1

Features

Compatible with Windows XP Professional SP2;

Windows of 2003 servers; Windows Vista, 7 and 8

Modular construction and freely programmable

Direct control of the network devices

List of measures to be taken for fire-fighting forces

Individual allocation of usage rights incl. priority scheduling

Integrated simulation-functions

Extensive recording of events and operations

Visualization of messages

Up to 12 active graphics simultaneously repres entable

Integration of video sequences possible

Information output via Windows print manager to multiple printers etc.

Time program/calendar function

Integrated database standard

Activation of other programs from WINMAGplus possible

Efficient programming language (SIAS) for custo-

mer-specific adjustment of interface and processes in case of alarm

Remote control possible via modem (optional)

10 printers per workstation possible

Multiple monitors can be used. 4 of 8 screens may be selected.

Windows management system for hazard detection systems

WINMAGplus has been specially developed to meet the requirements of managing and integrating hazard detection systems on a single PC platform. WINMAGplus simultan eously manages and displays graphically a number of security applications, using a common user interface including: fire detection technology; voice alarm public address; intrusion detection technology; access control technology; video technology; rescue route technology/escape door control, personnel protection systems and locating systems as well as fence monitoring systems. Apart from security systems, a multitude of building management control systems such as lighting, elevator control and fault detection systems as well as door/gate/barrier control systems can be managed and graphically displayed.

Database and user interface are designed in line with current standards: messages are displayed both graphically and in text format. WINMAGplus offers various application options, ranging from clearly displayed messages to active control of all detection devices. Based on our security networks IGIS-Loop and essernet, WINMAGplus is not only a highly professional system but also the best possible integrated visual data and management solution.

Program:

Thanks to its modular design, WINMAGplus offers suitable software for systems of any size and type of application, ranging from WINMAGplus basic package for single-station systems with one subsection being connected to the WINMAGplus multi-station system with multiple subsections being connected. Licensing enables the program options purchased and it legitimises program use. A dongle is acquired together with a license. The dongle must be plugged into a parallel interface or into a USB port of the WINMAGplus computer. With multi-station systems, every computer that is networked must be equipped with a dongle. Workstations that are not networked do not need a dongle. TIf the dongle is removed during operation, WINMAGplus runs for max. 72 hours in online mode.

Our services for installers:

Our WINMAGplus services include everything from entering alarm points to generating diagrams.

First of all, operators are made familiar with WINMAGplus. Then we work out the specifications together with the customer and develop SIAS programs. We design complete application packages and train your personnel. Until the final acceptance, we offer support for all installation processes and assist you during daily operation via a remote maintenance tool if required.

Interfaces, drivers:

Besides our security system drivers included in our product catalog, we offer a variety of drivers for all kinds of trades and manufacturers. Due to the continuously rising number of drivers, the current list of drivers can be requested when required. If the driver you need is not available, we will develop a driver geared to your requirements. Alternatively, all instru ments can be connected via the standard OPC interface. This is an international standard, which is supported by a multitude of manufacturers irrespective of their product lines. For developing your own drivers, we can provide you with the connection server and a developer’s package. Thus, individual WINMAGplus drivers can be created.

Hardware and software requirements:

Pentium 3 GHz or higher, minimum 512 MB RAM, minimum 1 GB of hard disk space, XGA graphics card with minimum 4 MB video memory, monitor with min. 1024x768 pixels, sound card with external speakers, Windows XP Professional SP 2, Windows 2003 Server, Vista and Windows 7 & 8, Internet Explorer version 6.0 or higher.

To order WINMAGplus licenses, please use the order form found in the back of the catalog.

48 www.hls-austria.com

Management Systems

013610

WINMAGplus

Control center software CD WINMAGplus basic kit

WINMAGplus control center software CD for hazard detection systems, license not included, compatible Windows XP Professional (SP3) 32-Bit version, Windows Server 2003 32-/64-Bit version, Windows Vista 32-/64-Bit version, Windows 7 & 8 32-/64-Bit version and Windows Server

2008 32-/ 64-Bit version. With the aid of this basic software and the corresponding licenses, hazard detection systems can be operated and managed via PC. Hazard reports are indicated in text form and graphically. In this way, the PC can also be used as an electronic emergency control point.

For demonstration purposes only, the WINMAGplus basic version operates without a license as a full version for a total of twenty 8-hour days, after which the program switches to offline mode. After expiry of the test time, all connections to all components are cut off. Starting in offline mode does not reduce the number of test runs. The demo mode is a full-function editing environment. All components function except the online communication. Each process can also be tested in demo mode through simulation and all editing functions can be used.

Please use order form printed in the appendix.

You can also download this software free of charge from our protected download area at

www.hls.austria.com.

Basic Licenses

013631

Upgrade Package

013616

013617

Basic license for WINMAGplus USB port

This basic license is used to activate the basic software package/demo version to operate as unrestricted visualizing software for server workstations and for network clients. For interfacing control panels to server workstations, further licenses are required (see 013601 – 013606, 013608,

013611, 013613, 013625).

Please use order form printed in the appendix.

Dongle for USB port

WINMAG upgrade to WINMAGplus

Upgrade of a WINMAG installation from version 6 to the newest WINMAGplus control center software.

For updating WINMAG V1 - 5 please use part no. 013617 in order form.

Please use order form printed in the appendix.

License file

WINMAG installation upgrade as of version 6

WINMAG installation upgrade to the most recent WINMAGplus control center software version

An existing WINMAG as of version 6 can be upgraded to the most recent WINMAGplus control center software version. For each installation with dongle (each connected PC) an upgrade version must be separately ordered.

Please use order form printed in the appendix.

10

11

12

13

14

8

9

6

7

2

3

4

5

49

Management Systems

Extension Licenses

013609

013601

013643

WINMAGplus

WINMAGplus control center software - subsequent upgrade

This order number serves as an auxiliary number for a subsequent optional extension or (e.g. additional client or subsequent connection of video systems) to an existing WINMAG installation from V

6.0. to V10 and WINMAGplus. The appropriate licenses must be ordered separately. The dongle need not be submitted.

Please use order form printed in the appendix.

WINMAGplus license - intrusion detection technology

License option for WINMAG/WINMAGplus basic software. Required if intrusion detection systems are connected to WINMAG.

This license may be ordered separately (subsequently) only in conjunction with the auxiliary number

013609. The update number of the basic license must be included when ordering. The license is used for connection of the Honeywell intrusion detection systems MB/HB, 5008 and Galaxy..

Please use order form printed in the appendix.

WINMAGplus license - Galaxy Dimension

License option for WINMAG/WINMAGplus basic software. Required if Honeywell Galaxy Dimension intrusion detection technology is connected to WINMAG.

This license may be ordered separately (as subsequent optional upgrade) only in conjunction with the auxiliary number 013609. The update number of the basic license must be included when ordering. The license is used for connection of the Honeywell intrusion detection systems.

Please use order form printed in the appendix.

013626

013603

WINMAGplus license - fire detection technology

License option for WINMAG/WINMAGplus basic software. Required if fire detection systems are connected to WINMAG.

This license may be ordered separately (as subsequent optional upgrade) only in conjunction with the auxiliary number 013609. The update number of the basic license must be included when ordering. The license is used for connection of the Honeywell IQ8Control, system 8000 1024, 1016 and FlexES Control fire detection systems.

Please use order form printed in the appendix.

WINMAGplus license - access control

License option for WINMAG/WINMAGplus basic software. Required if access control system devices are to be connected to WINMAG (e.g. ACS 2 and ACS 8). MultiAccess and/ or IQ MultiAccess software package is also required.

This license may be ordered separately (as a subsequent optional update) only in conjunction with the auxiliary number 013609. The update number of the basic license must be included when ordering. The license is used for the connection of the Honeywell ACS and (IQ) MultiAccess access control systems.

Please use order form printed in the appendix.

50 www.hls-austria.com

Management Systems

013604

013605

013608

WINMAGplus

WINMAGplus license - video technology

License option for WINMAG/WiINMAGplus basic software. Required if video technology equipment is to be operated via WINMAG. The crossbars can execute such commands as pan, zoom, tilt, select monitor etc., depending on the model. The following video crossbars are currently supported: Ernitec M 500 and M 1000; Honeywell MaxPRO 32; Philips LTC 8x00; Fusion series II /

III; Geutebrück Vicrosoft; Geutebrück Multiscope; Honeywell Fusion; HDPR series; contact your supplier for additional brands.

This license may be ordered separately (as a subsequent optional update) only in conjunction with the auxiliary number 013609. The update number of the basic license must be included when ordering.

Please use order form printed in the appendix.

WINMAGplus license - rescue route technology/escape door control

License option for WINMAG/WINMAGplus basic software. Required if rescue route techno logy/ escape door control equipment (only Honeywell Security) is to be operated via WINMAG.

The status of escape doors is graphically displayed.

This license may be ordered separately (as a subsequent optional update) only in conjunction with the auxiliary number 013609. The update number of the basic license must be included when ordering. The license is used for connecting Honeywell rescue route technology/escape door control equipment.

Please use order form printed in the appendix.

WINMAGplus license - RTD

License option for WINMAG/WINMAGplus basic license. Enables operation of WINMAG via modem, using DS 7600 and DGA 2400 to ESSER IDT (HB and MB series) and fire detec tion systems (1024 series).

This license may be ordered separately (as a subsequent optional update) only in conjunction with the auxiliary number 013609. The update number of the basic license must be included when ordering.

Please use order form printed in the appendix.

013661 Management software WINMAGPlus licence for Honeywell DTS detector

License option for WINMAG/WINMAGplus basic software. Required if Honeywell DTS linear heat detection systems is connected to WINMAG to receive, visualize fire alarm and foult states from

DTS zones.

10

11

12

13

14

8

9

6

7

2

3

4

5

51

Management Systems

Connection Server

013606

013607

WINMAGplus

WINMAGplus license connection server

License option for WINMAG/WINMAGplus basic software. Connection Server is a software module that enables the connection of a 3rd party device to WINMAG. Connection Server offers a convenient interface with which data and control commands can be exchanged bi- directionally in detection point format using WINMAG.

This license may be ordered separately (as a subsequent optional update) only in conjunction with the auxiliary number 013609. The update number of the basic license must be included when ordering.

Please use order form printed in the appendix.

Connection server developers kit

This developers kit can be used to program WINMAG/WINMAGplus connections to third party devices. The package contains the connection server developers kit including full documentation plus a one-day training session in Albstadt (Germany).

Please use order form printed in the appendix.

Dongle for USB port and license file

OPC

013618

013611

013612

Data points package

Package of 500 data points for project-related allocation of OPC tags, ESPA data points, etc.

The data points package can only be ordered in connection with the license 013590 universal gateway for PC and/or license 013611 OPC server.

Please use order form printed in the appendix.

WINMAGplus license – OPC server

Option for WINMAG/WINMAGplus basic software. Required if WINMAGplus is to act as an OPC server.

The OPC server license can only be ordered in conjunction with the 013618 license. This license may be ordered separately (as a subsequent optional update) only in conjunction with the auxiliary number

013609. The update number of the basic license must be included when ordering.

Please use order form printed in the appendix.

WINMAGplus license – OPC client

Option for WINMAG/WINMAGplus basic license. This is required if WINMAG is to display data from devices with OPC interfaces.

This license may be ordered separately (as a subsequent optional update) only in conjunction with the auxiliary number 013609. The update number of the basic license must be included when ordering.

Please use order form printed in the appendix.

52 www.hls-austria.com

Management Systems

Options

013613

013650

013652

013624

WINMAGplus

Option - notification

License option for WINMAG/WINMAGplus basic license. Required if SMS (text message), fax or e-mail are to be sent from WINMAG.

This license may be ordered separately (as a subsequent optional update) only in conjunction with the auxiliary number 013609. The update number of the basic license must be included when ordering. An

ISDN connection (S0) as well as an ISDN card are required for the notification function.

Please use order form printed in the appendix.

Option – escalation

Option for the WINMAG/WINMAGplus basic license. Required if short text messages dispatched by WINMAG are to be acknowledged. Without acknowledgment, pre- programmed escalation plans can be activated.

This license may be ordered separately (as a subsequent optional update) only in conjunction with the auxiliary number 013609. The update number of the basic license must be included when ordering. For the escalation license, the 013613 notification license is required. A PC sound card is required for this function.

Please use order form printed in the appendix.

Option – ability for customized interface rights (client-side)

Option for the WINMAG/WINMAGplus basic license, allowing individual assignment of interfaces and rights to several operators.

This license may be ordered separately (as a subsequent optional update) only in conjunction with the auxiliary number 013609. The update number of the basic license must be included when ordering.

Please use order form printed in the appendix.

Option – redundance

Option for redundant connection of essernet and IGIS-Loop security networks to the WINMAG server. Interface operation for redundant networks is based on master/backup operation and prevents data loss in WINMAG objects in case of disruption of network connections caused by cable defects or COM port failure.

Please use order form printed in the appendix.

1

013625

10

11

12

13

14

8

9

6

7

2

3

4

5

Option – client

License option for WINMAG/WINMAGplus basic license. Enables operation of one client station in a computer network with one server workstation. The license must be installed at the server workstation. Clients require only the WINMAG software to be installed. One WINMAG client license is needed per client.

This license may be ordered separately (as a subsequent optional update) only in conjunction with the auxiliary number 013609. The update number of the basic license must be included when ordering.

Please use order form printed in the appendix.

53

Management Systems

013653

013655

WINMAGplus

WINMAGplus – 4-monitor support option

Option for WINMAGplus basic license. Enables the allocation of 4 monitors from a choice of 8 monitors. This option only works with WINMAGplus.

This option requires a special graphics card with up to 8 outputs in the WINMAG hardware.

This option must be ordered per workstation which uses the multi-monitor option.

WINMAGplus – AutoCAD option

Option for WINMAGplus basic license. Enables the placement of detectors and groups directly from ACAD LT. The drawings are saved as dxf files. The detectors/groups are placed as hyperlinks in the ACAD drawing and stored. When importing these ACAD draw ings into WINMAGplus, the symbols of the disciplines are automatically placed onto the correct position in the drawing. An

ACAD license must be provided by the customer.

Please use order form printed in the appendix.

54 www.hls-austria.com

Management Systems

Application Example

WINMAGplus

1.

WINMAGplus single station system with an essernet connection max. 15 m

Serial essernet interface max. 1000 m

FACP essernet max. 1000 m

WINMAGplus control centre

WINMAGplus software requirements:

1 x CD WINMAGplus control center software

1 x Basic license WINMAGplus control center software

1 x License fire detection technology

Part No. 013610

Part No. 013631

Part No. 013626

2.

WINMAGplus multi station system - one server and two clients with an essernet connection max. 1000 m

FACP max. 15 m essernet

Serial essernet interface max. 1000 m max. 1000 m

LAN

WINMAGplus server

LAN

10

11

12

13

14

8

9

6

7

2

3

4

5

WINMAGplus client 1

WINMAGplus software requirements:

1 x CD WINMAGplus control center software

1 x Basic license WINMAGplus control center software

1 x Licence fire detection technology

2 x License WINMAGplus client

WINMAGplus client 2

Part No. 013610

Part No. 013631

Part No. 013626

Part No. 013625

55

Management Systems

Application Example

3.

WINMAGplus multi station system - one server and two clients with a multi subsection connection

max. 15 m

Video technology crossbar or digital video recorder e. g.

WINMAGplus server

IGIS-LOOP controller

FACP

IGIS-Loop

WINMAGplus

IAP

IAP

LAN

WINMAGplus client 1 WINMAGplus client 2

WINMAGplus software requirements:

1 x CD WINMAGplus control center software Part No. 013610.10

1 x Basic licence WINMAGplus control center software Part No. 013631.10

1 x License intrusion detection technology Part No. 013601.10

1 x License fire detection technology

1 x License access control technology

1 x License video technology

2 x License WINMAGplus client

Part No. 013626.10

Part No. 013603.10

Part No. 013604.10

Part No. 013625.10

4.

WINMAGplus multi station system - 1 main server,

1 redundant server, 3 client workstations

- with an essernet connection

max. 15 m

Serial essernet interfaces max. 15 m

WINMAGplus server 1

WINMAGplus server 2

LAN

Access control

IQMultiAccess

FACP essernet

FACP

ACS 2 plus

FACP

WINMAGplus client 1 WINMAGplus client 2 WINMAGplus client 3

WINMAGplus software requirements:

Server 1

1 x CD WINMAGplus control center software Part No. 013610.10

1 x Basic license WINMAGplus control center software Part No. 013631.10

1 x License fire detection technology

4 x License WINMAGplus client

1 x License option redundance

Part No. 013602.10

Part No. 013625.10

Part No. 013624.10

Server 2

1 x Basic license WINMAGplus control center software

Part No. 013631.10

1 x License fire detection technology

Part No. 013610.10

56 www.hls-austria.com

Management Systems WINMAGLite

Digital Recorder

Fusion e. g.

SEI

FAP or

IAP or

Access

Control

WINMAGLite

Application example

013635

Features

Cost-effective management software for hazard detection systems

Visualizing and controlling of only one hazard detection central control panel (FDS, VAPA, IDS, RRT, AC)

Visualizing and controlling of VisiOprime or Fusion video management systems

Management of up to 500 detection points

Processing of up to 100 status reports per second

Processing of up to 100 macro processes

Connection of log and alarm printers

Information display via monitor and/or printer

(Windows standard printer)

Adjustable program background

Flexible, window-oriented graphics

Display and location of detectors in diagrams

Status information indicators

Pre-defined alarm reports

Simulation function

Extensive event and operation logging

Users possible

WINMAGLite with USB dongle

WINMAGLite is a cost effective first step to hazard detection systems management. Ease of operability as well as pre-defined, practical central control panel and detection point types facilitate the commissioning and operation of WINMAGLite.

WINMAGLite is perfect for small systems for which no expansions or connection of further hazard detection control panels are planned in the near future. Thus, the Lite version is perfectly suitable for a broad range of applications, even for WINMAG professionals.

Especially small objects can be professionally secured due to a combination of a hazard detection system with the Honeywell video management systems of Honeywell VisiOprime. WINMAGLite provides the user with almost all basic WINMAG functions. Unlike the full version, this version can initially connect only one hazard detection central control panel.

The user has access to pre-defined programs which can automatically be adjusted via a text editor to the respective situation on site.

The alarm stack which was implemented in previous WINMAG versions is replaced through symbols displayed in the top bar which indicate alarms. The new feature improves overall clarity so that the user can react more quickly in the case of an alarm.

Hardware and software requirements:

Pentium processor 3 GHz or higher, min. 512 MB RAM , min. 1 GB hard disk, XGA graphics card with min. 4 MB video memory, monitor with 1024 x 768 pixels or more, sound card with external speakers,

Windows XP Professional SP2, Vista, Windows 7 & 8 and Windows 2003 Server, Internet Explorer 6.0 or higher.

Please use order form printed in the catalog.

Training for this product is offered. Please contact our training department.

Basic CD control center software package WINMAGLite

Accessories

Please take note that for connecting one essernet is needed consisting of SEI and fire alarm system.

013636 WINMAGLite upgrade to WINMAGplus full version

If the WINMAGLite system limits have been reached, an upgrade to the full version of Winmagplus is possible, since both systems have access to the same database. WINMAG options are not part of the upgrade and must be ordered separately.

WINMAGplus options are not included in the upgraded version and must be ordered separately.

Please use order form on www.esser-systems.com.

10

11

12

13

14

8

9

6

7

2

3

4

5

57

Management Systems Difference WINMAGLite vs. WINMAGplus

Difference WINMAGLite vs. WINMAGplus

Differences between WINMAG Lite and WINMAG plus

WINMAG Lite is the inexpensive starter version of the hazard management system WINMAG plus with reduced features. It is used for visualization and control of a single hazard detection control panel. The following table shows the most important features of both programs.

In this comparison, you can see whether WINMAG Lite is sufficient for an application or WINMAG plus must be used.

The data structure of WINMAG Lite and WINMAG plus is identical. It is possible to change from WINMAG Lite to the full version.

Item No.

Interfaces

I/O points per object

Setting of I/O points

Special I/O Types

Event display

Meta data

Alarm stack

User

Tool bars

SIAS-programs

SIAS language

Alarm display

WINMAG Lite

013635

1 hazard detection control + any

Fusion video devices

500 individual yes yes yes not available

3 predefined, can be renamed predefined predefined , no special programs no individual programming counter and pop-ups with individual t ext

Alarm criteria

Graphics

Supported monitors predefined identical to WINMAG plus, but without

- multi-monitor

- AutoCAD

2

Number of graphics unlimited

Graphics displayable at once 13

Symbol actions

Creating special s ymbols

Multi station functions

Mandantory

Timer programs

State monitoring

Printer allocation

Licensing

S ystem configuration list predefined no

list no no no no

1 dongle without options

WINMAG plus

013630/13631+ Options as desired, depending on options

32000 individual yes yes yes yes unlimited, free definable configurable configurable, extensible full featured identical to WINMAG Lite, alarm programs with a in addition larm stacks configurable several formats like

- bmp, jpg, png, emf, wmf

- AutoCAD-Integration (optional)

4 from 8 (optional) unlimited

48 configurable , special functions yes yes yes yes yes

15 dongle with options

58 www.hls-austria.com

Automatic Detectors

Series ES Detect (Intelligent non-addressable)

Series IQ8Quad (Conventional)

Intrinsically Safe

Base Series IQ8Quad, ES Detect

Accessories

8

9

6

7

10

11

60-63

64-75

76-81

82

83-95

12

13

14

2

3

4

5

59

Automatic Detectors Series ES Detect (Intelligent non-addressable)

1

117

The ES Detect automatic detector is an intelligent non-addressable detector specifically designed for operation on conventional detector groups. ES Detect sets new standards in conventional technology through high quality sensors with advanced detec tion technology. These include not only the intelligent algorithms for fire detection but also the wide range of different types of detectors, including multisensor detectors OTblue and O²T. ES Detect also helps to save costs, because with the implemented drift compensation, ES Detect can be operated a full eight years, instead of five years for ordinary detectors, according to DIN 14675. Numerous accessories are available from the program of the IQ8Quad detector series. The ES Detect is equipped with a logo for optical differentiation. The convenient maintenance with the programming software tools 8000 (in preparation) completes the full spectrum of ES Detect, from which the operating data of the detector (for example, the measured values, contamination, alarm counters, operating hours counter ...) can be read and stored. The detectors remain where they were installed, because the complete detector group can be connected to a PC and serviced via the field bus interface (Part No. 789862.10).

62

Fire detector with base

Features

System benefits:

With multisensor detectors for the detection of all fires, even under the most difficult operating conditions

Up to 30 detectors per detection group.

Reliable detection:

Uniform response sensitivity of the detector for all different types of fire for the multisensor detectors

Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences

Automatic adaptation to varying environmental influences

Electronic compensation of long-term influences of contamination or aging

Reliable false alarm suppression:

High reliability against false alarms by temporal evaluation of different sensor criteria

Exclusion of signal forms not typical of fires through special filter algorithms

Automatic self-monitoring of the detector electronics

Automatic self-monitoring of sensors for function and condition

Maintenance:

Designation of the heat detector by a black ring on the light pipe

Hours of operation, alarm and fault counter in each detector

Operation data retrieval of all detectors of a group with standard service PC and field bus interface

Detector LED for alarm display and as an identification display in the service (for maintenance with 8000 tools)

Wide range of accessories:

Standard socket and relay base

Socket adapter for ceiling installation

Dust caps optional for fire detectors and detector base

Kit for suspended mounting

Technical Data

Operating voltage

Alarm current @ 9 V DC

Air speed

Storage temperature

Air humidity

Type of protection

Material

Color

Weight

Dimensions

Special colors on request!

8 ... 42 V DC typ. 9 mA

0 ... 25.4 m/s

-25 °C ... 75 °C

< 95 % (non-condensing)

IP 43 (base + option)

ABS white, similar to RAL 9010 approx. 110 g

Ø: 117 mm H: 49 mm (62 mm inkl. Sockel)

In order to pass through existing wires, the WAGO grips (e.g., type 243-204 (O 0.5-1 mm) or

ES Line

Detector base is not supplied as standard

Z 1

Accessories

767800 assembly bracket

805590 standard IQ8Quad detector base

805591 detector base with IQ8Quad relay contact

Z 2

Z 3

Z 4

FlexES Control

esserbus loop length max.

3.5 km

Spur max. 1,000 m per zone

Z 1

Z 2

Z 3

Z 4

60 www.hls-austria.com

Automatic Detectors

1

800171

1

800177

1

800271

Series ES Detect (Intelligent non-addressable)

Fixed heat detector ES Detect

Approval: G 213068

Automatic heat detector with fast semiconductor sensor for reliable detection of fires with distinctive heat. Fire detector with decentralized intelligence, automatic function self-test, alarm and operations data storage and alarm display. A remote indicator can also be connected.

Technical Data

Quiescent current @ 9 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification approx. 25 μA max. 30 m² max. 7.5 m

-20 °C ... 50 °C

EN 54-5 A1S

Special marking for heat detector on the light pipe: black ring

Fixed heat detector ES Detect, Class B

Approval: G 213067

As 800171, however, for increased response temperature according to EN 54-5 class B.

Technical Data

Quiescent current @ 9 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification approx. 25 μA max. 30 m² max. 6 m

-20 °C ... 65 °C

EN 54-5 BS

Special marking for heat detector on the light pipe: black ring

Rate-of-rise detector ES Detect

Approval: G 213069

Automatic heat detector with fast semiconductor sensor for reliable detection of fires with rapid temperature rise and integrated maximum value function for the recognition of fires with slow temperature rises. Fire detector with decentralized intelligence, automatic function self-test, alarm and operations data storage and alarm display.

A remote indicator can also be connected.

Technical Data

Quiescent current @ 9 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification approx. 25 μA max. 30 m² max. 7.5 m

-20 °C ... 50 °C

EN 54-5 A1R

Special marking for heat detector on the light pipe: black ring

8

9

6

7

2

3

4

5

12

13

10

11

14

61

Automatic Detectors

1

800371

1

800375

1

800374

Series ES Detect (Intelligent non-addressable)

Optical smoke detector ES Detect

Approval: G 213066

Scattered-light smoke detector for reliable early detection of fires. Fire detector with decentralized intelligence, automatic function self-test, automatic environmental adaptation, alarm and operating data storage and alarm display.

A remote indicator can also be connected.

Technical Data

Quiescent current @ 9 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification approx. 30 μA max. 110 m² max. 12 m

-20 °C ... 72 °C

EN 54-7

OT blue

multisensor detector ES Detect

Approval: G 213065

Multisensor detector with integrated optical smoke and heat sensor. The optical measurement chamber is equipped with a novel sensor which allows the detection of open fires, smoldering fires and fires with high heat.

The classical ionization detector is replaced by these detection methods, especially in open fires.

This detector is also capable of detecting test fires TF1 and TF6 described in the EN 54-9:1982.

The OTblue multisensor is a fire detector with temporal signal analysis, weighted combination of sensor data, decentralized intelligence, automatic function self-test, automatic environmental adaptation, alarm and operating data storage and alarm display.

A remote indicator can also be connected.

Technical Data

Quiescent current @ 9 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification approx. 35 μA max. 110 m² max. 12 m

-20 °C ... 50 °C

EN 54-7/-5 A2, CEA 4021

O

2

T multisensor detector ES Detect

Approval: G 213070

Multisensor detector with two integrated optical smoke sensors with different scattered light angles as well as additional heat detector sensor evaluation for detecting anything from smoldering fires to open fires with uniform response characteristics. Compares smoke sensor signals for smoke classification and reduction of false alarms from water vapor or dust, for example. Due to its excellent detection properties, the detector is also capable recognizing test fires TF1 and TF6 described in the standard. The O²T multisensor detector is also suitable for higher application temperatures of up to +65° C.

A remote indicator can also be connected.

Technical Data

Quiescent current @ 9 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification approx. 45 μA max. 110 m² max. 12 m

-20 °C ... 65 °C

EN 54-7/-5 B, CEA 4021

62 www.hls-austria.com

Automatic Detectors

1

800361.10

1

805592

Series ES Detect (Intelligent non-addressable)

Optical Smoke Detector Detect ES with relay contact, 48 V DC operation

The threshold value detector with relay contact 800361.10 comprises an optical smoke detector

800371 from the ES Detect series and a detector base 805592 which enables a direct connection to a 48 V DC power supply. The detector therefore does not need to be operated in connection with a fire alarm control panel.

If the detector detects a fire alarm, a floating relay contact activates to transmit the alarm. The relay contact is normally open (NO) by default, but can also be configured as normally closed (NC) with a solder strap on the circuit board base.

A typical use for this detector is to monitor mobile communication stations, e.g. BTS base transceiver stations.

Take note, the Detector base with relay output for ES Detect 805592 is included in the scope of delivery!

Technical Data

Operating voltage

Quiescent current

Current consumption

Contact load relay

Area to be monitored

Height to be monitored

Air speed

Application temperature

Storage temperature

Air humidity

Type of protection

Material

Color

Weight

Detector specification

Dimensions

Replacement for Part No. 761306

42 ... 58 V DC approx. 0.051 mA (@ 48 V DC) max. 9 mA

30 V DC / 1A, 60 V DC / 0,45 A max. 110 m² max. 12 m

0 ... 25.4 m/s

-20 °C ... 72 °C

-25 °C ... 75 °C

< 95 % (non-condensing)

IP 43 (with base and option)

ABS white, similar to RAL 9010 approx. 110 g (ca. 190 g incl. base)

EN 54-7

Ø: 117 mm H: 49 mm (incl. base 62 mm)

Detector base with relay output for ES Detect 800631.10

Detector base with relay contact output, for ES Detect detector family. Suitable for 48 V DC operation.

Contact: floating normally open or normally closed, selectable via coding strap, factory setting: normally open.

A typical use for this base with ES Detect detector is to monitor mobile communication stations.

Technical Data

Operating voltage

Contact load relay

Connection terminal

Application temperature

Storage temperature

Air humidity

Material

Color

Weight

Dimensions

42 ... 58 V DC

30 V DC / 1A, 60 V DC / 0,45 A

Ø 0,6 mm ... 2 mm²

-20 °C ... 72 °C

-25 °C ... 75 °C

< 95 % (non-condensing)

ABS white, similar to RAL 9010 approx. 80 g

Ø: 117 mm H: 24 mm (incl. detector 62 mm)

Cable entry on the side or bottom plate.

For looping existing wires, for example, the type 243-204 WAGO terminals (Ø 0.5 mm Ø 1.0 mm) or 273 to 104 (0.75 mm-2.5 mm) are used.

Not for use with IQ8Quad detectors!

Not for use in esserbus and powered loop ringbus!

Contained in Part No. 800361.10

Replacement for Part No. 781582

8

9

6

7

2

3

4

5

12

13

10

11

14

63

Automatic Detectors Series IQ8Quad (Intelligent Addressable)

Automatic intelligent fire detectors with high reliability and low power consumption used for premises and items of property with medium and high concentration of valuable assets.

Detector series IQ8Quad features, system advantages

• Designed for optimal operation on System 8000 and IQ8Control fire alarm systems

• with multisensor fire detectors for the detection of all types of fires, even under the most difficult operating conditions.

• Detector with and without loop isolator

Different options of installation

• wiring in loop and spur combination, e.g.

• maximum number of detectors with cable lengths of up to 3,500 m with installation cable for fire detection, e.g. cables I-Y(St)Yn x 2 x 0.8 mm

• up to 127 detectors and detector zones per loop installation

• up to 32 detectors per zone

Easy commissioning

• automatic detector addressing

• fixed address assignment of detector location, even after detectors have been replaced or added

• localization of wire breaks and short circuits on loop

• detector-LED used as alarm indicator and as an indicator for detectors in service

• adaptation to changing operating conditions

• dedicated LED for indicating operation (green LED)

• disconnection of individual detectors, detector zones and detection areas

• disconnection of individual sensors or several sensors at once within a multisensor fire detector; either manually or depending on programmed time of the day

Automatic adaptation to varying environmental conditions

• compensation of changing levels of air pressure, humidity, smoke c• centration according to the double chamber principle

• electronic compensation of long-term influences like aging or pollution

Reliable detection

• constant alarm sensitivity of multisensor fire detector for all types of fire

• large signal to noise ratio due to the special design of the sensors and the electronics to suppress electromagnetic interference

Reliable false alarm suppression

• high immunity against false alarms by means of timed evaluation of different sensor criteria

• signal patterns not typical for fires are eliminated by using special filter algorithms

• automatic self-monitoring of detector electronics

• continuous loop monitoring even during short-circuits through isolating the relevant segment

• automatic monitoring of all sensors to guarantee operational capacity and correct condition.

Increased operating reliability

• short-circuit and wire break tolerant through monitoring from both ends of the loop

• alarm decision inside detector

• fail-safe circuit activated if communication fails

Maintenance

• automatic maintenance request

• heat detector identification through a black circle on the light transmission plate

• multisensor gas detector identification through a golden loop on the circle transmission plate

• operating time-, alarm- and fault counter in each detector

• automatic, cyclic loop check

• complete status interrogation from the control panel

• interrogation of operating data from all detectors on loop via standard service PC and detector interface

Comprehensive range of accessories

• standard detector base and relay base

• base adapter for ceiling mounting

• dust cover for fire detector or detector base

• kit for suspended ceiling mounting

• RF base

64 www.hls-austria.com

Automatic Detectors Series IQ8Quad (Intelligent Addressable)

Detectors w/o Integrated Alarm Devices

117

62

Fire detector with base

Technical Data

Alarm current w/o communication curtain approx. 18 mA

Air speed

Storage temperature

Air humidity

Type of protection

Material

Color

Weight

Dimensions

0 ... 25.4 m/s

-25 °C ... 75 °C

< 95 % (non-condensing)

IP43 (with base + option)

ABS plastic white, similar to RAL 9010 approx. 110 g

Ø: 117 mm H: 49 mm (62 mm incl. base)

Special-color on demand

The detectors Part No. 802271, 803271, 802371, 803371, 802373, 802374 and 803374 are approved in the scope of the DIBt system authorization for the operation with an Automatic

Door System.

Detector base is not supplied as standard

Accessories

767800 Mounting bracket

805590 Standard detector base for IQ8Quad

805591 Detector base with relay contact for IQ8Quad

1

802171 Fixed heat detector IQ8Quad with isolator

Approval: VdS, CNBOP, BOSEC

1

802177

Automatic heat detector with a single thermistor to sense the air temperature around the detector.

Fast semiconductor sensor guarantees reliable detection of fires with strong heat generation. Ideal for sensing in environments that are dirty or smoky under normal conditions, as well it is unaffected by wind or atmospheric pressure. Intelligent fire detector with decentralized intelligence, automatic function self-test, CPU failure mode, alarm and operating data memory, alarm indicator, soft- addressing and operating indication.

The detector is provided with an integrated isolator. A parallel detector indicator can be connected.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification

Declaration of Performance

8 ... 42 V DC approx. 40 μA approx. 220 μA @ 42 V max. 30 m² max. 7.5 m

-20 °C ... 50 °C

EN 54 - 5 A1S / -17

DoP-20102130701

Special marking for heat detector on the light pipe: black ring.

Fixed heat detector IQ8Quad (class B), with higher operating temperature with isolator

Approval: VdS

Same as 802171, but for increased operating temperature according to EN 54-5 class B.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification

Declaration of Performance

8 ... 42 V DC approx. 40 μA approx. 220 μA @ 42 V max. 30 m² max. 6 m

-20 °C ... 65 °C

EN 54-5 BS / -17

DoP-20411130701

Special marking for heat detector on the light pipe: black ring.

8

9

6

7

2

3

4

5

12

13

10

11

14

65

Automatic Detectors

1

802271

1

802371

1

802373

Series IQ8Quad (Intelligent Addressable)

Rate-of-rise heat detector IQ8Quad with isolator

Approval: VdS, CNBOP, BOSEC

Automatic heat detector with a single thermistor to sense the air temperature around the detector.

Fast semiconductor sensor guarantees reliable detection of fires with rapidly rising temperatures and integrated fixed temperature function for the detection of fires with slowly rising temperatures.

Ideal for sensing in environments that are dirty or smoky under normal conditions, as well it is unaffected by wind or atmospheric pressure. Intelligent fire detector with decentralized intelligence, automatic function self-test, CPU failure mode, alarm and operating data memory, alarm indicator, soft-addressing and operating indication.

The detector is provided with an integrated isolator. A parallel detector indicator can be connected.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification

Declaration of Performance

8 ... 42 V DC approx. 40 μA approx. 220 μA @ 42 V max. 30 m² max. 7.5 m

-20 °C ... 50 °C

EN 54-5 A1 / -17

DoP-20103130701

Special marking for heat detector on the light pipe: black ring.

Optical smoke detector IQ8Quad with isolator

Approval: VdS, CNBOP, BOSEC

Optical smoke detector which works using the light scatter principle to guarantee safe and early detection of fire. Responds well to slow-burning, smouldering fires. Intelligent fire detector with decentralized intelligence, automatic function self-test, CPU failure mode, alarm and operating data memory, alarm indicator, soft-addressing and operating indication. The detector is provided with an integrated isolator. A parallel detector indicator can be connected.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification

Declaration of Performance

8 ... 42 V DC approx. 50 μA approx. 280 μA @ 42 V max. 110 m² max. 12 m

-20 °C ... 72 °C

EN 54-7 / -17

DoP-20104130701

OT multisensor fire detector IQ8Quad with isolator

Approval: VdS

Multisensor fire detector with integrated optical sensor and heat sensor which give both a combined signal as well as a separate heat signal for improved false alarm management, with time-controlled signal analysis and weighted data combination of both detector functions for detecting smoldering fires and fires with extreme heat generation. Intelligent detector with decent ralized intelligence, self-function test, CPU redundancy mode, automatic adaptation to the environ ments, alarm and operating data storage, alarm indication and soft addressing.

The loop isolator is integrated in the detector. A parallel detector indicator is additionally attachable.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification

Declaration of Performance

9 ... 42 V DC approx. 50 μA approx. 280 μA @ 42 V max. 110 m² max. 12 m

-20 °C ... 50 °C

EN 54-7/-5 A2 /-17, CEA 4021

DoP-20111130701

66 www.hls-austria.com

Automatic Detectors

802374

1

802375

Series IQ8Quad (Intelligent Addressable)

O

2

T multisensor fire detector IQ8Quad with isolator

Approval: VdS, CNBOP, BOSEC

Multisensor fire detector provided with two built-in optical smoke sensors with different scattered light angles as well as additional heat detector sensor evaluation to guarantee the detection of different types of fire from smoldering fires to open fires with constant sensitivity level. Smoke sensor signal identification to ensure smoke classification and reduction of false alarms caused by interferences, for instance, water vapor or dust. Used when early and reliable fire detection is requested. Because of its excellent detection characteristics and enhanced false alarm management, the detector is also able to identify the standardized TF1 and TF6 test fires. The O²T multisensor fire detector is also suitable for applications with higher temperatures of up to +65 °C. The detector is provided with an integrated isolator. A parallel detector indicator can be connected.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification

Declaration of Performance

8 ... 42 V DC approx. 60 μA approx. 330 μA @ 42 V max. 110 m² max. 12 m

-20 °C ... 65 °C

EN 54-7/-5 B /-17, CEA 4021

DoP-20105130701

OTblue multisensor fire detector IQ8Quad with isolator

Approval: VdS

Multisensor fire detector with integrated optical sensor and heat sensor with enhanced false alarm management. The optical measurement chamber is provided with a patented developed sensor technology using a high-sensitive blue LED (instead of the commonly used red LED in Optical smoke detectors), enabling the detection of open fires, smoldering fires and fires with high heat generation. Especially for open fires, the classical ionization technology implemented in ionization detectors is replaced by the unique detection technology, unlike ionization detectors, this sensor works without a radioactive element which causes problems at the time of refuse disposal. The detector is capable of identifying the TF1 and TF6 test fires described in the EN 54-9:1982 specification. Well suited for sensitive environment, detection of invisible up to large aerosols.

The OTblue multisensor is an intelligent detector with time-related signal analysis, signal correlation of the sensor data, decentralized intelligence, automatic function self-test, CPU failure mode, automatic adaptation to environmental conditions, alarm and operating data memory, alarm indicator and soft-addressing.

The detector is provided with an integrated isolator and a parallel detector indicator can be connected.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Area to be monitored

Height to be monitored

Application temperature

Material

Detector specification

Declaration of Performance

9 ... 42 V DC approx. 50 μA approx. 280 μA @ 42 V max. 110 m² max. 12 m

-20 °C ... 50 °C

ABS

EN 54-7/-5 A2 /-17, CEA 4021

DoP-20113130701

8

9

6

7

2

3

4

5

12

13

10

11

14

67

Automatic Detectors

1

802473

Series IQ8Quad (Intelligent Addressable)

OTG multisensor fire detector (CO) IQ8Quad with isolator

Approval: VdS

Multisensor fire detector with integrated smoke detector, heat detector and gas sensor (CO) with enhanced false alarm management, for preventive and early detection of deep-seated smouldering fires which give a lot of CO as well as flaming fires through combined evaluation of scattered light, temperature and gas. An alarm is actuated at carbon monoxide (CO) concentration levels that are life-threatening for humans. Less susceptible to false alarms caused by dust, as well earliest and reliable detection of fire development due to the additional detection of CO. Also a Technical Alarm

(TAL) can be programmed with the flexible programmable CO threshold up to 150 ppm. The detector is provided with an integrated isolator. A parallel detector indicator can be connected.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Quiescent current @ FACP battery

CO pre-alarm

CO alarm

Area to be monitored

Height to be monitored

Application temperature

Detector specification

Declaration of Performance

8 ... 42 V DC approx. 65 μA approx. 225 μA @ 27,5 V approx. 360 μA @ 42 V approx. 75 ppm approx. 100 ppm max. 110 m² max. 12 m

-20 °C ... 50 °C

EN 54-7/-5 A2 /-17, CEA 4021

DoP-20115130701

In the course of installation, we recommend testing the integrated CO sensor with our CO test gas (Part No. 805583) or CO capsule (Part No. 805553).

Durability CO sensor: 5 years

Technical alarm range CO: 10 ppm … 150 ppm

Gas sensors (CO) mainly react to the carbon monoxide arising from a fire (CO). They have, however, also a cross sensitivity to other gases, as for example hydrogen (H2), acetylene

(C2H2) or nitric oxide (NO).

Special marking for gas detector on the light pipe: golden ring.

68 www.hls-austria.com

Automatic Detectors Series IQ8Quad (Intelligent Addressable)

Detector with Integrated Alarm Devices

Features

Detection

The reliable O²T multisensor principle for consistent response performance at the highest level of security against false alarms

Flash lamp

Loop powered - no need for external power supply

No additional short address

Automatic synchronization of various IQ8Quad alarm signaling devices

High flash energy

Sounder

Loop powered - no need for external power supply

No additional short address

Automatic synchronization of various IQ8Quad alarm signaling devices

Maximum sound level: 92 dB (A) at 1 m

Maximum sound pressure can be set

Multiple signal patterns can be combined to one signal

Signal pattern and repetition rates can be set

20 different signal tones, incl. DIN-tone

Speech massage with sounder

Loop powered - no need for external power supply

No additional short address

Automatic synchronization of various IQ8Quad alarm signaling devices

Maximum sound level: 92 dB (A) at 1 m

Maximum sound pressure can be set

Multiple signal patterns can be combined to one signal

Signal pattern and repetition rates can be set

20 different signal tones, incl. DIN-tone

Speech messages can be played in up to 5 languages

5 alarm messages per languages are prepro grammed

The IQ8Quad smoke detectors with built-in alarm device incorporate up to 4 different func tionalities

(detect, flash, sound, and/or speech) depending on the type (O²T/F, O²T/So, O²T/ Sp, O²T/FSp) of detector.

- fire detection as per EN 54-7

- integrated heat sensor as per EN 54-5

- optical alarm via flash lamp

- acoustic alarm via sounder as per EN 54-3/A2

- acoustic alarm speech messages as per EN 54-3/A2

- short-circuit isolator as per EN 54-17

Detection

Multisensor detectors with two built-in optical smoke sensors with different scattered light angles as well as additional heat detector sensor evaluation for detecting everything from smouldering fires to open fires with consistent response performance. Smoke sensor signal identification to ensure smoke classification and reduction of false alarms caused, for instance, by water vapor or dust.

Each detector is provided with an integrated isolator.

Alarm signaling

The alarm signaling device is activated by the control panel. No further short address needs to be allocated. It is programmed with tools 8000 as of software version 1.05.

Alarm tone / speech message programming

For detectors with speech message and/or alarm tone function with up to five language options, up to 4 signals can be programmed. Two signals are reserved for alarm signaling and evacuation in the case of fire. Two further signals can be programmed for other events. Each signal can consist of up to four signal components, enabling one signal to be programmed as a DIN tone combined with subsequent speech messages in three different languages.

Alarm tones can be chosen from a table with various tone types. For application in schools, a break signal to signify the breaks between class can be activated.

Four different speech messages, each in three languages, are available:

- "An incident has been reported in the building. Please await further instructions.”

- "Attention” please. This is an emergency. Please leave the building by the nearest avail able exit.”

- "This is a fire alarm. Please leave the building immediately by the nearest available exit.”

- “This is a test message. No action is required. “

When the basic setting is selected, signals / signal components can be continuously repeated until the signalling function is interrupted by the control panel. They can also be programmed with a repetition rate of one to three times. Thus, the break signal in schools can be deliberately set to only one repetition. In the same way, the total signal can be set to continuous repetition, with the

DIN tone being played only once while subsequent speech messages are played up to three times.

Sound pressure programming

The sound level [dB (A)] can be set to eight levels, from approximately 64dB (A) to approx imately

92dB (A).

8

9

6

7

2

3

4

5

12

13

10

11

14

69

Automatic Detectors Series IQ8Quad (Intelligent Addressable)

All the security you need in one housing with four functions: detection, flasher, sounder and speech alarm.

All IQ8Quad detectors with built-in alarm devices can only be operated on the powered loop. For physical reasons, an increased sound level leads to a higher current consumption rate of the alarm device, the respective load factor must be considered when calculating the maximum number on the loop. Altogether up to 127 bus devices per loop can still be connected.

Please consider that extra training is required when dealing with IQ8Quad with a built-in alarm device.

The training includes installation planning and commissioning techniques. For further information take a look at our training brochure. Information concerning the calculation can be found in the "Project Planning Support“ chapter.

signal 1

(evacuation) sequence 1 sequence 2 sequence 3 sequence 4

Signals signal 2

(alarm) signal 3

(event 1) signal 4

(event 2) sequence 1 sequence 1 sequence 1 sequence 2 sequence 2 sequence 2 sequence 3 sequence 3 sequence 3 sequence 4 sequence 4 sequence 4

70 www.hls-austria.com

Automatic Detectors Series IQ8Quad (Intelligent Addressable)

Detector with Integrated Alarm Devices

Country code acc. to ISO

3166 -Alpha-2

Language code acc. to ISO 639-1

Evacuation 1

Germany

(DE) de

Dies ist ein

Feueralarm. Bitte verlassen Sie das

Gebäude umgehend über die nächsten Fluchtwege. Die Feuerwehr ist alarmiert.

Great Britain

(GB) en

This is a fire alarm.

Please leave the building immediately by the nearest available exit.

France

(FR) fr

Evacuation 2

Achtung, Achtung!

Dies ist eine Gefahrenmeldung. Bitte verlassen Sie das

Gebäude über die nächsten

Ausgänge.

Alarm

Achtung, im Gebäude ist eine

Gefahrensituation gemeldet worden.

Bitte bleiben Sie ruhig, und warten

Sie auf weitere

Anweisungen.

Attention please.

This is an emergency. Please leave the building by the nearest available exit.

An incident has been reported in the building. Please await further instructions.

Ceci est une alarme incendie,veuillez

évacuer immédiatement les locaux par la sortie la plus proche.

Votre attention s'il vous plaît, ceci est une alarme. Veuillez

évacuer les locaux par la sortie la plus proche.

Un incident est signalé dans le batiment. Merci de garder votre calme et attendez les prochaines instructions.

Test-message All-Clear

Dies ist eine

Testdurchsage.

Die Gefahrensituation ist jetzt behoben. Wir entschuldigen uns für jegliche

Unannehmlichkeiten.

This is a test message.

No action is required.

The emergency is now cancelled. We apologize for any inconvenience.

Ceci est un test.

L'alarme est à présent annulée.

Veuillez nous excuser pour le désagrément.

Spain

(ES)

Italy

(IT) es it

Esto es una alarma de incendio.

Abandonen por favor el edificio inmediatamente por la salida de evacuación más cercana.

Attenzione.

Allarme incendio.

Abbandonare l'edificio tramite l'uscita di emergenza più vicina.

Atención. Esto es una emergencia.

Por favor abandonen el edificio por la salida de evacuación más cercana.

Attenzione.

Allarme in corso.

Vi preghiamo di recarvi presso l'uscita di emergenza più vicina.

Atención, se ha reportado un incidente en el edificio.

Aguarden por favor otras instrucciones.

Attenzione.

E' stato rilevato un allarme.Ulteriori disposizioni vi verranno comunicate appena possibile.

Esto es un mensaje de prueba.

No se requiere ninguna acción.

La emergencia ha sido cancelada.

Pedimos disculpas por las molestias causadas.

Attenzione.

E' in corso una prova di allarme.

Non è richiesta alcuna azione.

Attenzione. Cessato allarme.La situazione di normalità è stata ripristinata.

Standard speech messages of IQ8Quad detectors and IQ8Alarm - for other languages also refer to the appendix!

10

11

8

9

12

6

7

4

5

No.

Description

1

2

3

Frequency

School bell

FP 1063.1 Telecoms

BS 5839 Pt1

BS 5839 Pt1 complex

Alternating 800 / 970 Hz at 2 Hz

Alternating 800 / 970 Hz at 1 Hz

BS 5839 Pt1

BS 5839 Pt1

Intermittent 970 Hz at 1 Hz 0.5 sec.

Intermittent 2850 Hz at 1 Hz 0.5 sec.

BS 5839 Pt1

BS 5839 Pt1

Intermittent 970 Hz 1/4 sec. ON - 1 sec. OFF

Continuous 970 Hz

Sweep tone 800 Hz tp 970 Hz at 7 Hz BS 5839 Pt1

BS 5839 Pt1

DIN Tone

DIN 33404 Part 3

1200 - 500 Hz at 1 Hz

French fire sound

Sweep tone 800 Hz to 970 Hz at 1 Hz

554 Hz / 100 ms + 440 Hz / 400 ms + 10 %

NL - Slow Whoop 500 Hz - 1200 Hz at 3.5 sec. break of 0.5 sec.

13 US - Horn Continuous 485 Hz

14

15

16

17

18

19

20

US - Horn with

Temporal Pattern

US - March

Time

US - Slow

Whoop

US - Siren

US - Hi/Lo

US - NFPA

Whoop

IMO

GA-Signal

Intermittent 485 Hz

(0,5 sec. ON; 0.5 sec. OFF; 3 times; 1.5 sec. OFF; Repeat)

Alternating 485 Hz

(0,25 sec. ON; 0.25 sec. OFF; Repeat)

Sweep tone 500 Hz to 1200 Hz

(4.0 sec. ON; 0.5 sec. OFF; Repeat)

Sweep tone 600 Hz to 1200 Hz

(1,0 sec. ON, Repeat)

Alternating 100 Hz / 800 Hz

(0.25 sec. ON; Alternate; 0.25 sec. ON; Alternate; Repeat)

Sweep tone 422 Hz to 775 Hz

(upwards sweep 0.85 sec.; 3 times; 1 sec. OFF; Repeat)

Intermittent 800 Hz (1,0 sec. ON; 1,0 sec.

OFF: 7 times; 2.0 sec. ON: 2.0 sec. OFF; Repeat)

IQ8Quad detectors and IQ8Alarm tone table

Pulse rate complex f f f f f

0.25 sec.

0.25 sec.

0.5 sec.

0.5 sec.

0.5 sec.

0.5 sec.

0.5 sec.

0.5 sec.

0.25 sec.

1.0 sec.

f

10 ms f f

1.0 sec.

f f

1.0 sec.

0.4 sec.

0.1 sec.

f

3.5 sec.

0.5 sec.

f f f f

0.5 sec.

0.5 sec.

0.25 sec.

0.25 sec.

4.0 sec. 0.5 sec.

1.0 sec.

f f

0.25 sec.

0.25 sec.

0.85 sec.

f f

1.0 sec.

1.0 sec.

1.5 sec.

1.5 sec.

1.5 sec.

1.0 sec.

t t t t t t t t t t t t t t t t t t t

8

9

6

7

2

3

4

5

12

13

10

11

14

71

Automatic Detectors Series IQ8Quad (Intelligent Addressable)

Detector with Integrated Alarm Devices

117

65

Fire detector with base

Technical Data

Operating voltage

Area to be monitored

Height to be monitored

Air speed

Application temperature

Storage temperature

Air humidity

Type of protection

Material

Color

Weight

Dimensions

8 ... 42 V DC max. 110 m² max. 12 m

0 ... 25.4 m/s

-20 °C ... 65 °C

-25 °C ... 75 °C

≤ 95 % (without condensation)

IP 42

ABS plastic white, similar to RAL 9010 approx. 145 g

Ø: 117 mm H: 59 mm

Ø: 117 mm H: 67 mm (incl. base)

Detector bases are not supplied as standard.

The 769836 demo package is available for presentations. Further data can be viewed in the accessories section for automatic detectors.

Special-colors on demand!

It is not possible to use the detector base with relay (part no. 805591).

When connected with parallel indicator does not allow to program parallel indicator.

Detector base is not supplied as standard

Accessories

767800 Mounting bracket

805590 Standard detector base for IQ8Quad

IQ8Control C

flash signal speech flash

Application example

sound

esserbus-PLus

Loop length max. 3.5 km

esserbus transponder speech speech

72 www.hls-austria.com

Automatic Detectors

1

802382

1

802383

1

802384

Series IQ8Quad (Intelligent Addressable)

O/So optical smoke detector IQ8Quad

Approval: VdS

O/So optical smoke detector IQ8Quad with integrated sounder

Scatter smoke detector for safe and early detection of smouldering fires with light smoke generation. Intelligent detector with decentralised intelligence, automatic function self-test, CPU failure mode, alarm and operating data memory, alarm indicator, soft-addressing and operating indication.

The detector is provided with a loop isolator.

Along with smoke detection components, the detector is provided with a built-in sounder.

Technical Data

Quiescent current @ 19 V DC

Load factor

Sound level

Detector specification

Specification approx. 50 μA

2 max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone

EN 54-7, EN 54-17

EN 54-3 acoustic signaling device

Not suitable for application in detector base 805591!

O

2

T/F multisensor IQ8Quad

Approval: VdS

O²T/F multisensor IQ8Quad with integrated flasher

In addition to smoke detection with the conventional O²T multisensor technology, the detector is provided with a built-in flash lamp.

Technical Data

Quiescent current @ 19 V DC

Load factor

Lighting energy

Strength of light

Signal flashing lamp

Detector specification approx. 75 μA

2 approx. 3 Y max. 15,8 cd peak / 2,63 cd effective red

EN 54-7/-5 B/-17, CEA 4021

Not suitable for application in detector base 805591!

O

2

T/So multisensor IQ8Quad

Approval: VdS

O²T/So multisensor IQ8Quad with integrated sounder

In addition to smoke detection with the conventional O²T multisensor technology, the detector is provided with a built-in alarm signalling device. The sound level can be set to eight different levels.

Technical Data

Quiescent current @ 19 V DC

Load factor

Sound level

Type of protection

Detector specification

Specification approx. 80 μA

2 max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone

IP 42

EN 54-7/-5 B/-17, CEA 4021

EN 54-3 acoustic signaling device

Not suitable for application in detector base 805591!

8

9

6

7

2

3

4

5

12

13

10

11

14

73

Automatic Detectors

1

802385

1

802385.SV98

Series IQ8Quad (Intelligent Addressable)

O

2

T/FSp multisensor IQ8Quad

Approval: VdS

O²T/FSp multisensor IQ8Quad with integrated flasher, sounder and speech

In addition to smoke detection with the conventional O²T multisensor technology, the detector is provided with a built-in voice alarm device. It can be set to eight different levels.

Technical Data

Quiescent current @ 19 V DC

Load factor

Sound level

Lighting energy

Strength of light

Signal flashing lamp

Detector specification

Specification approx. 90 μA

3 max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone approx. 3 Y max. 15,8 cd peak / 2,63 cd effective red

EN 54-7/-5 B/-17, CEA 4021

EN 54-3 acoustic signaling device

EN 54-3 acoustic speech signallng device

Not suitable for application in detector base 805591!

Programmed with 5 standard languages: German, English, Spanish, French and Italian

O

2

T/FSp multisensor detector IQ8Quad with composition of other languages

Approval: VdS

O²T/FSp multisensor IQ8Quad with integrated flasher, sounder and speech

As 802385, but with an individual combination of national languages, see special order form in the appendix.

When ordering, please note the “Ordering information for IQ8Quad and IQ8Alarm” and fill in “Order form for individual combination of languages” printed in the appendix.

Cancellations or returns are not possible.

Not suitable for application in detector base 805591!

Programmed with an individual combination of up to 5 languages.

1

802385.SV99

O

2

T/FSp multisensor detector IQ8Quad, customized version

Approval: VdS

O²T/FSp multisensor IQ8Quad with integrated flasher, sounder and speech

As 802385, but with individual text and/or sounds. The max. recording time per device is 169 seconds.

When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in “Order form for individual combination of languages” printed in the appendix.

Costs for the recording of customer-specific texts and/or tones can be obtained by request.

Cancellations or returns are not possible.

Not suitable for application in detector base 805591!

Programmed according to customer specifications.

74 www.hls-austria.com

Automatic Detectors

1

802386

1

802386.SV98

1

802386.SV99

Series IQ8Quad (Intelligent Addressable)

O

2

T/Sp multisensor IQ8Quad

Approval: VdS

O²T/Sp multisensor IQ8Quad with integrated sounder and speech

In addition to smoke detection with conventional O²T multisensor technology, the detector is provided with a built-in voice alarm device. It can be set to eight different levels.

Technical Data

Quiescent current @ 19 V DC

Load factor

Sound level

Detector specification

Specification approx. 90 μA

3 max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone

EN 54-7/-5 B/-17, CEA 4021

EN 54-3 acoustic signaling device

EN 54-3 acoustic speech signaling device

Not suitable for application in detector base 805591!

Programmed with 5 standard languages: German, English, Spanish, French and Italian

O

2

T/Sp multisensor IQ8Quad, special language

Approval: VdS

As 802386, but special language.

When ordering, please note the “Ordering information for IQ8Quad and IQ8Alarm” and fill in “Order form for individual combination of languages” printed in the appendix.

Programmed with individual combination of up to 5 standard languages.

O 2 T/Sp multisensor IQ8Quad, customized version

Approval: VdS

As 802386, but with individual text and/or sounds. The max. recording time per device is 169 seconds.

When ordering, please note the “Ordering information for IQ8Quad and IQ8Alarm” and fill in “Order form for individual combination of languages” printed in the appendix.

8

9

6

7

2

3

4

5

12

13

10

11

14

75

Automatic Detectors Intrinsically Safe

Series IQ8Quad Ex (i)

117

62

Fire detector with base

Technical Data

Data according to ATEX:

Max. Input Voltage (U

Max. Input current (I i

)

Max. Output current (I i

) o

)

Max. internal capacity (Ci)

Ambient temperature (Ta)

EC-type examination certificate

Ex-category

Explosion protection

Common technical data:

Operating voltage

Alarm current @ 9 V DC

Air speed

Storage temperature

Air humidity

Type of protection

Material

Color

Weight

Dimensions

21 V DC

252 mA

10 mA

1 nF

-20 °C ... 70 °C

TÜV 09 ATEX 554910

II 2G (with Ex barrier Part No. 804744 or 764744)

Ex ib IIC T4 Gb

8 ... 42 V DC typ. 18 mA

0 ... 25.4 m/s

-25 °C ... 75 °C

< 95 % (non-condensing)

IP 43 (incl. base + option)

ABS white, similar to RAL 9010 approx. 110 g

Ø: 117 mm H: 49 mm (62 mm incl. base)

Detector bases are not supplied as standard.

Fully addressable devices for installation in hazardous areas with direct connection of the Ex barrier (Part No. 804744) on the loop, without spending a loop address for the connection via a transponder as in case of the conventional connection.

Additional detectors for the explosion zones can be found in the chapters manual call points and special detectors. Detailed information about installation and operation can be found in the documentation (Part No. 798920) on our website.

All of the following IQ8Quad intrinsically safe fire detectors must be operated with the Part

No. 805590 base. In the case of operation in standard zones, no individual addressing is possible!

For usage in zone 1 and zone 2 in case of operation

- with individual addressing the Ex barrier Part No. 804744,

- in conventional zones the Ex barrier Part No. 764744 must be used!

The Ex barrier separates intrinsically safe and non-intrinsically safe circuits before the explosion prone area to be monitored (explosion zone).

Individual addressable operating

Zone 1 esserbus/esserbus-PLus

Ex area: IIC T2

Ex barrier (Part No. 804744)

Conventional operating

Zone 1 esserbus/esserbus-PLus external power supply

Ex area: IIC T2

Ex barrier (Part No. 764744)

Application example

esserbus transponder 4 zone / 2 relay

76 www.hls-austria.com

Automatic Detectors

1

803271.EX

1

803371.EX

Intrinsically Safe

Rate-of-rise heat detector IQ8Quad Ex (i) w/o isolator

Approval: VdS, ATEX

Automatic heat detector with a single thermistor to sense the air temperature around the detector.

The fast semiconductor sensor for the reliable recognition of fires with a single thermistor to sense the air temperature around the detector. The fast semiconductor quick rate of temperature rise as well as integrated fixed temperature heat function for the recognition of fires with slow temperature rise. Ideal for sensing in environments that are dirty or smoky under normal conditions, as well it is unaffected by wind or atmospheric pressure.

Intelligent fire detector with decentralized intelligence, automatic function self-test, emergency mode, storage of alarm and operating data, alarm display. Soft addressing and separate operational display is only possible when operating an esserbus / esserbus-PLus IQ8Quad detector without loop isolator, especially for usage in explosion zones. Operation with individual addressing at Ex barrier Part No. 804744 and as standard detector at Ex barrier Part No. 764744.

Technical Data

Quiescent current @ 19 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification approx. 40 μA max. 30 m² max. 7.5 m

-20 °C ... 50 °C

EN 54-5 A1R : 2002

Special marking for heat detector on light pipe: black ring

Accessories

805590 Standard detector base for IQ8Quad

Optical smoke detector IQ8Quad Ex (i) w/o isolator

Approval: VdS, ATEX

Scattered-light smoke detector for reliable early recognition of fires. Responds well to slow- burning, smouldering fires. Intelligent fire detector with decentralized intelligence, automatic func tion selftest, emergency mode, storage of alarm and operating data, alarm display. Soft addressing and separate operational display is only possible when operating an esserbus / esserbus-PLus

IQ8Quad detector without loop isolator, especially for usage in explosion zones. Operation with individual addressing at Ex barrier Part No. 804744 and as standard detector at Ex barrier Part No.

764744.

Technical Data

Quiescent current @ 19 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification

Declaration of Performance approx. 50 μA max. 110 m² max. 12 m

-20 °C ... 70 °C

EN 54-7 : 2006

DoP-20914130701

Accessories

805590 Standard detector base for IQ8Quad

8

9

6

7

2

3

4

5

12

13

10

11

14

77

Automatic Detectors

1

803374.EX

Intrinsically Safe

O

2

T multisensor fire detector IQ8Quad Ex (i) w/o isolator

Approval: VdS, ATEX

Intelligent detector with two integrated optical smoke sensors with different scattered-light angles as well as additional heat detector sensor evaluation for the recognition of smoldering fires up to open fires with uniform characteristics. Comparison of the heat sensor signals for smoke classification and reduction of false alarms by interferences, e.g. from steam or dust. Due to its excellent detection characteristics, and enhanced false alarm management, the detector is also able to recognize TF1 and TF6 test fires, described in the standards. The O²T intelligent detector is also suitable for a higher operating temperature of up to +65 °C. Used when early and reliable fire detection is requested. Intelligent fire detector with decentralized intelligence, automatic function self-test, emergency mode, storage of alarm and operating data, alarm display. Soft addressing and separate operational display is only possible when operating an esserbus / esserbus-PLus

IQ8Quad detector without loop isolator, especially for usage in explosion zones. Operation with individual addressing at Ex barrier Part No. 804744 and as standard detector at Ex barrier Part No.

764744.

Technical Data

Quiescent current @ 19 V DC

Area to be monitored

Height to be monitored

Application temperature

Detector specification

Declaration of Performance approx. 60 μA max. 110 m² max. 12 m

-20 °C ... 65 °C

EN 54-7:2006 / -5B:2000 / A1:2002, CEA 4021

DoP-20915130701

Accessories

805590 Standard detector base for IQ8Quad

78 www.hls-austria.com

Automatic Detectors Intrinsically Safe

Accessories for IQ8Quad EX (i)

1

804744 Ex barrier for intrinsic safe detectors Series IQ8Quad Ex (i)

Approval: ATEX

Ex barrier for the operation of intrinsically safe IQ8Quad Ex (i) series detectors directly on the esserbus/esserbus PLus with individual addressing in connection with the detector base Part No.

805590.

Technical Data

Ambient temperature

Air humidity

Type of protection

Weight

Specification

Dimensions

-20 °C ... 60 °C

< 95 % (non-condensing)

IP 20 approx. 100 g

EN 54-18:2005

W: 20 mm H: 107 mm D: 115 mm

A safety barrier does not replace an overvoltage protection according to IEC 801, DIN VDE

0185 and 0855.

You can find more detailed information on the installation and the operation for IQ8Quad Ex

(i) Series detectors in the documentation Part No. 798920.

System requirements

- Number of detectors up to max. 10 fire detectors per Ex barrier

- Max. 4 Ex barriers per loop.

- At least one esserbus device with a isolator must be installed between two Ex barriers.

- Total loop length up to max. 3,500 m.

- For each Ex barrier the total loop length must be reduced about 200 meters.

- Cable length (spur) within the Ex area max. 400 m per Ex barrier.

- Load factor 3 per Ex barrier (Use load factor calculation tool).

Individual addressable operating

Zone 1 esserbus / esserbus-PLus

Ex area: IIC T2

Ex barrier (Part No. 804744)

Application example

8

9

6

7

2

3

4

5

12

13

10

11

14

79

Automatic Detectors

1

764744

1

764745

Intrinsically Safe

Ex barrier for intrinsic safe detectors Series IQ8Quad Ex (i) and 9100

Approval: ATEX

Ex-barrier for the operation of intrinsically safe IQ8Quad Ex (i) series detectors in connection with the detector base Part No. 805590 as well as the 9100 Ex (i) series in connection with the detector base Part No. 781590.

Technical Data

Ambient temperature (Ta)

Air humidity

Dimensions

-20 °C ... 60 °C

< 95 % (non-condensing)

W: 12.5 mm H: 115 mm D: 110 mm

A safety barrier does not replace an overvoltage protection according to IEC 801,

DIN VDE 0185 and 0855. VdS approval is not required.

You can find more detailed information on the installation and the operation in the documentation Part No. 798920 for IQ8Quad Ex (i) series detectors and Part No. 798913 for 9100 Ex

(i) series detectors.

System requirements

- Number of detectors up to max. 8 fire detectors per zone.

- Loop length per zone up to max. 300 m. (Total length measured from the terminals of the detector zone).

Conventional operating

Zone 1 esserbus/esserbus-PLus external power supply

Ex area: IIC T2

Ex barier (Part No. 764744)

Application example

esserbus transponder 4 zone/2 relay

Isolation and assembly block for safety Ex barrier

For insulated (earth-free) mounting of Part No. 764744 Ex barrier onto standard hat rail.

Isolation block

Part No. 764745

Ex barrier ground

Hatrail

80 www.hls-austria.com

Automatic Detectors

1

764752

Features

Chemically resilient

Temperature resilient

Flame retardant

Non-corrosive

Sea water resistant

Non-halogen, UV resistant

1

764754

Intrinsically Safe

Housing for Ex barrier

Polyester-housing for the installation of up to max. 10 Ex barriers with integrated inside mounting rail. Also for operational application under extreme environmental conditions suitable.

Technical Data

Type of protection

Housing

Color

Dimensions

Mounting material

IP66 glass-fiber reinforced polyester gray, similar to RAL 7000

W: 255 mm H: 250 mm D: 160 mm

Cable gland for housing 764752

Threaded cable connection for housing Part No. 764752.

Technical Data

Ambient temperature

Type of protection

Material

Color

Cable diameter

-20 °C ... 95 °C

IP66

Polyamide blue, similar to RAL 9005

8 mm

8

9

6

7

2

3

4

5

12

13

10

11

14

81

Automatic Detectors Base Series IQ8Quad, ES Detect

1

805590 Standard detector base for IQ8Quad

Features

A lot of space for wire connection

Automatic closing of the loop bus wiring system for detector extraction

Detector extraction locking is enclosed in the base

Technical Data

Connection terminal

Application temperature

Storage temperature

Material

Color

Weight

Dimensions

Ø 0.6 mm to 2 mm²

-20 °C ... 72 °C

-25 °C ... 75 °C

ABS white, similar to RAL 9010 approx. 60 g

Ø: 117 mm H: 24 mm (incl. detector 62 mm)

Cable entry on the side or through the bottom plate.

Wago clamps for looping in wires, e.g. type 243-204 (Ø 0.5 mm - Ø 1.0 mm) or 273-104

(0.75 mm² - 2.5 mm²) can be mounted on the detector base.

1

805591 Detector base with relay contact for IQ8Quad

IQ8Quad detector base with relay contact output. Contact: floating NO or NC contact selectable via jumper. Settings on site: NO contact.

Features

Provides a voltage-free contact controlled by the remote output of a detector

Draws negligible current

A lot of space for wire connection

Automatic closing of the loop bus wiring system for detector extraction

Detector extraction locking is enclosed in the base

Technical Data

Current consumption

Contact load relay

Connection terminal

Application temperature

Storage temperature

Air humidity

Material

Color

Weight

Dimensions

5 µA (w/o detector, active relay)

30 V DC/1 A

Ø 0.6 mm to 2 mm²

-20 °C ... 72 °C

-25 °C ... 75 °C

< 95 % (non-condensing)

ABS white, similar to RAL 9010 approx. 80 g

Ø: 117 mm H: 24 mm (incl. detector 62 mm)

Cable entry on the side or through the bottom plate. Connection of remote indicators not allowed!

Wago clamps for looping in wires, e.g. type 243-204 (Ø 0.5 mm - 1.0 mm) or 273-104 (0.75 mm²- 2.5 mm²) can be mounted on the detector base.

Not suitable for application with IQ8Quad with integrated alarm device Part No. 802383,

802384, 802385 and 802386 as well as 802385.SVxx and 802386.SVxx!

82 www.hls-austria.com

Automatic Detectors

Accessories for Series IQ8Quad, ES Detect

1

805588

1

805587

1

805589

1

805571

Accessories

Detector cover for IQ8Quad w/o built-in alarm sounder

The cover plate protects the IQ8Quad detector against contamination during construction or renovation works.

The detector covers can only be used for IQ8Quad fire detectors without built-in alarm sounder! Application only for detector types with Part No: 802171, 802271, 802371, 802374,

802375 and 802473.

50 pcs

Base cover for IQ8Quad

The cover plate protects the IQ8Quad detector base against contamination during construction or renovation works.

50 pcs

Detector cover for IQ8Quad with built-in alarm sounder

The cover plate protects the IQ8Quad detector against contamination during construction or renovation works.

The detector covers can only be used for IQ8Quad fire detectors with built-in alarm sounder!

Application only for detector types with Part No: 802283, 802384, 802386 and 802385.

50 pcs

Flush mount kit for base IQ8Quad

Adapter for installation in ceilings and for mounting the detector bases IQ8Quad (Part No. 805590 and 805591) to the bottom side of false ceilings.

Technical Data

Application temperature

Storage temperature

Air humidity

Type of protection

Material

Color

Weight

-20 °C ... 72 °C

-25 °C ... 75 °C

< 95 % (non-condensing)

IP 40

ABS, plastic white, similar to RAL 9010 approx. 165 g (with surface ring)

8

9

6

7

2

3

4

5

12

13

10

11

14

3 mm

140 mm

175 mm

117 mm

20 mm

45 mm

60 mm

Application example

83

Automatic Detectors

1

805574

Accessories

4" trim ring and snap-in mounting clips for IQ8Quad detector base

Snap-in mounting clips and trim ring for base installation, e.g. for installation on 4” electrical boxes.

Take note, the label plate Part No. 805576 is not applicable.

Technical Data

Material

Color

Dimensions

ABS plastic white, similar to RAL 9010

Ø: 155 mm H: 19 mm (outside)

1 x Trim ring and 2 x snap-in mounting clips

1

805576

Application example

Label plate for detector base IQ8Quad

Before or after the installation of the detector, the label plate can be inserted at the side slot of the

IQ8Quad detector base.

For identification purposes the detector can be provided with the detector address and detector zone for ceilings with a maximum height of 3 m.

A label can be attached to the inscription field. Blank labels can be marked when using a PC, e.g. SIGEL Part No. LP725-white (58 x 18 mm) or other suppliers of writing materials.

There is a help file in the download area for creating the printing material.

Applicable for base 1x Part No. 805590/91 with 805570; for 805593.10, 805594.10.

Not to be used for base 1x Part No. 805590/91 in combination with 805571, 805572, 805573,

805574.

10 pcs

Application example

84 www.hls-austria.com

Automatic Detectors

1

805577

1

805570

Accessories

Mounting adapter for intermediate ceilings

The mounting adapter is used for the quick and secure attachment of bases of the IQ8Quad detector series, 9x00, IQ8Alarm and alarm signaling devices, parallel detector indicators, etc. to suspended ceiling systems. It saves the usage of special hollow cavity fasteners, since the mounting screws of the bases are screwed directly into the slots of the mounting adapter. The mounting adapter offers additional advantages in the fixing of the cables, rigid/flexible cable inlays and threaded cable connections.

Technical Data

Material

10 pieces

ABS

Dimensions in mm

44.0

39.0

2.8 31.0

10.0

49.0

23.0

21.5

40.0

99.0

Application examples for fixing of the cables, rigid/flexible cable inlays and threaded cable connections

IP43 protection for detector base IQ8Quad, flat design

For installation in environments with dust and humidity. The IP protection protects the IQ8Quad detector base against dust and humidity. It increases the protection level to IP 43. For easy mounting to the base, the IP protection is provided with an adhesive film.

Technical Data

Type of protection

Material

Color

Dimensions

10 pcs

IP43

SBR/NR white, similar to RAL 9010

Ø: 117 mm H: 3 mm

8

9

6

7

2

3

4

5

12

13

10

11

14

85

Automatic Detectors

1

805572.50

Accessories

IP43 damp room base adapter for IQ8Quad, ES Detect detector base

The damp room socket adapter was designed specifically for the surface mounted cable feed through cable protection pipes and has three breakthrough inputs for cable glands (optional).

Suitable for IQ8Quad and ES Detect detector base.

Technical Data

Type of protection

Material

Color

IP43

ABS white, similar to RAL 9010

Please follow the installation instructions on the adapter!

Substitute for Part No. 805572

Cable glands (Part No. 704147, 704148) are not included.

1

805573

59,6 59,6

15,8

5,4 ø

119,3

6,0

6,0

46,0

111,4

119,3

Application example (labeling field and cable glands optional)

IP43 protection for detector base IQ8Quad, deep design

Same as 805570, but as universal protection. Additionally, the seal prevents humidity from entering at the sides.

Technical Data

Type of protection

Material

Color

5 pcs

IP43 rubber white, similar to RAL 9010

86 www.hls-austria.com

Automatic Detectors

1

805560

1

781482

Accessories

EMV isolator for IQ8Quad, ES Detect detector base

In fire alarm systems where a high electromagnetic interference/EMI load (e.g. by fluorescent lamps or electrical control devices) must be expected it is recommended to mount the EMI-Module in the standard detector base (Part No. 805590) of the corresponding fire alarm detectors.

The EMI-Module must only be operated in conjunction with standard IQ8Quad detector base

(without relay board) and only for detectors without integrated alarm devices (Part No.

802382 to 802386, incl. adapted variants).

10 pcs

Application example

Kit for suspended installation

Kit for detector bases (Part No. 781590, 805590 and 805591) for suspended installation with pendulum stabilizer, cable entry at the top, pull relief by means of PG cable entry including junction box with terminals. The detector height can be adjusted individually depending on the cable length to bridge over the heat cushion below the ceiling.

Technical Data

Material

Installation

Color

Dimensions

It is not possible to use telescopic rods.

Not suitable for series 3000.

As shown in the left picture

ABS plastic attached to the zone cable white, similar to RAL 9010

Ø: 84 mm H: 15 mm (aluminum-stabilizer)

Heat cushion: Smoke-free area

Filled with smoke:

Detection guaranteed

8

9

6

7

2

3

4

5

12

13

10

11

14

6-pole terminal inside

Cable entry with cord grip

Standard detector cable

Gap between screws suitable for detector series

78xxxx and 80xxxx

Detector base can be equipped with

IP protection 805570 or 805573

87

Automatic Detectors

1

781550

Accessories

Protective cage

Protective cage for detectors

Steel basket for protection from damage and also unauthorized disconnection of the detector.

Technical Data

Material

Color

Dimensions steel with paint coating white, similar to RAL 9010

Ø: 140 mm H: 115 mm

Can be used with all bases, IP43 moisture-proof adapter, also for wireless base and wireless gateway.

850054

850055

Application example with IQ8Wireless detector base and IQ8Alarm

Special painting IQ8Quad detector base

The IQ8 detector base is painted and delivered according to the required RAL color.

For identical colors, we suggest to order a suitable number for serial purposes.

When ordering please specify:

- RAL code

- Glossy, semi-matt, matt finishing

Special painting IQ8Quad

As 850054, but for automatic detectors of the IQ8Quad series.

88 www.hls-austria.com

Automatic Detectors Accessories

Testquipment for Several Detector Series

1

805580 Detector removal tool

It is suitable for removing series 9x00 as well as IQ8Quad detectors. Through optional adaptation of the suction cup to the corresponding insert on the detector removal tool, the IQ8Quad detector covers (Part No. 805588 and 805589) and the base covers for IQ8Quad (Part No. 805587) can be attached as well as removed. The detector removal tool can be adapted to the telescope rod Part

No. 060426 and 060427 as well as with Part No. 805581 to 769813.

Snap on detector removal tool, then spin clockwise and remove the detector.

1

805581

Application example

Adapter for pole 769813

The adapter for the pole (Part No. 769813) is designed for attaching the Part No. 805580 detector removal tool and the Part No. 805582 smoke detector tester.

8

9

6

7

2

3

4

5

12

13

10

11

14

1

060426 Plastic telescopic extension

Telescopic extension for plastic telescopic rod (Part No. 060427). Up to 3 telescopic extensions can be attached to the telescopic rod. The maximum height that can be reached is increased to 9 m.

Technical Data

Material

Length

Fiberglass

1.13 m

Features

Easy aid for daily maintenance of high ceilings

Stable construction

Important for attaching and releasing detectors

Extremely high level of flexural strength due to fiber-plastic composite material

Totalock TM for easy and secure locking

89

Automatic Detectors

1

060427

Accessories

Plastic telescopic rod

Extendable detector pull-down pole made of glass-fiber reinforced plastic for adapting the Part No.

805580 detector removal tool as well as testers with Part No. 060429 and 805582.

Technical Data

Material

Length

Fiberglass

4.5 m

Features

Length of 1.26 m in retracted state

4 segments, lockable

1

805586

Features

Exterior lid with Velcro fastening transportation straps for telescopic rod and extensions

Inside lid with 2 storage compartments for battery backs Part No. 060431

Inside compartment with up to three optional dividers

Big front pocket, with up to two optional dividers

Wide shoulder strap with sliding shoulder pad and additional handles

Cover with carrying strap for up to 4 telescopic rods Part No. 060427 and/or extensions 060426

Carrying bag for test equipment

The carrying bag has many pockets and compartments in which the ESSER smoke alarm testers, test gas bottles, all cables and other maintenance accessories can be stored. So everything you need for maintenance can always be found in one place. The upholstered, adjustable shoulder strap ensures very easy and comfortable transport. An additional advantage: the bag protects equipment from dirt and moisture.

Technical Data

Dimensions W: 480 mm H: 420 mm D: 260 mm (carrying bag)

1 x Carrying bag and 1 x cover for telescopic rods/extensions

Capacity of the protective carrying bag:

3 x Smoke detector tester

2 x Battery baton

1 x Telescopic rod

Front pocket for charger, test gas, etc.

Up to 4 telescopic rods in a special cover

Capacity of the carrying bag

90 www.hls-austria.com

Automatic Detectors Accessories

1

805551

Features

Generation of smoke, heat and CO in a single test unit

Clearing cycle of the detector via integrated ventilator for better reset

Simultaneous or sequential testing with various stimuli

Suitable for single and multi-criteria fire detectors

Suitable for smoke-, heat- and gas- (CO) detectors

Targeted heat rays provide fast activation of heat sensors (up to 90°C/194°F, and/or adjustable up to 100°C/212°F)

Test activation via infrared barrier, no mechanical triggering, no ceiling contact necessary

Easy, fast and efficient testing, as changing of testing device is not necessary

Multilingual and user-friendly menu control:

English, German, Spanish, French, Italian,

Dutch, Swedish

Battery operated portable device

Environmentally friendly and safe through usage of test cartridges instead of test gas cans

Multi-stimulus detector tester TF 2001

Detector tester kit Testifire 2001 for the functional testing of point-type fire detectors with various sensors. The activating stimuli for smoke, heat and CO (carbon monoxide) are generated in this testing unit. Thus the changing of test tools for different types of detectors is no longer necessary.

All fire detector types can be tested with only one test instrument. The test tool is suitable for all optical smoke detectors, ionization detectors, CO detectors and heat detectors. It facilitates fast and effective testing of single and intelligent multisensor fire detectors. So testing of the different sensors can be carried out one after another or for all at the same time.

The required stimuli are generated on demand at the time of test from the corresponding capsule

(smoke or CO). Pressurized gas cans are no longer being used.

The selection of the testing stimuli, as well as their combination and sequence are menu driven via keypad and are represented on the display (multilingual). So e.g. simultaneous or sequential testing, or also a combination thereof, can be easily programmed and then carried out at the detector. The activation of the testing device occurs automatically, as soon as the detector interrupts the light barrier integrated in the device. If necessary, a clearing phase can be chosen between the specific testing criteria that enables the stimuli to be blown out of the detector immediately for the next test by the integrated ventilator.

The currently active criterion is represented by a multi-colored LED indicator and is clearly recognizable even from large distances. The fill-level of the respective test resource capsules can be shown in the display. Warnings are indicated automatically e.g. if a capsule is nearly empty. The capsules offer much higher test capacities in comparison with aerosol cans.

The power supply of the testing head occurs via Ni-MH batteries (metal hydride batteries) in the adapter between testing head and telescopic rod. Charging of the battery occurs with the charger optionally via adapter (100-230 V AC) or via 12 V DC input (vehicle cigarette lighter).

Suitable for IQ8Quad and 9x00 detector series.

Technical Data

Battery charging

Heat detector response threshold

Ambient temperature

Storage temperature

Air humidity

75-90 minutes up to 90°C adjustable up to 100°C

5 °C ... 45 °C

-10 °C ... 50 °C

< 85 % (non-condensing)

Detector tester kit Testifire 2001 consists of:

Testing head, smoke capsule, CO capsule, 2 Ni-MH battery packs, charger

Accessories

805552 Smoke capsule for multi-stimulus detector tester 805550/51

805553 CO capsule for multi-stimulus detector tester 805551 (Testifire TC3)

060426 Plastic telescopic extension

060427 Plastic telescopic rod

060431 Spare battery baton

Selection of different test criteria displayed

Smoke

Heat

CO

Menu Status

Example of testing with only one stimuli

Smoke 1

Heat 2

CO 3

Menu Status

Example of sequential testing (all criteria successively)

Smoke 1

Heat 1

CO

Menu Status

Example of a simultaneous testing

(smoke + heat at the same time)

Smoke 1

Heat 1

CO 2

Menu Status

Example of combination of simultaneous and sequential testing)

8

9

6

7

2

3

4

5

12

13

10

11

14

91

Automatic Detectors Accessories

805550

Features

Creation of smoke and heat with one single test device

Desmoking of detector via an integrated fan for fast resetting

Simultaneous or successive testing with different activating materials

Suitable for single and multi-criteria detectors

Suitable for smoke and heat detectors

Targeted heat radiation facilitates quick activation of the thermal sensors (up to 90°C/194°F and/or can be switched up to 100°C/212°F)

Test activation through infrared barrier, no mechanical triggering, ceiling contact not necessary

Quick, easy and efficient testing since there is no need to exchange test device

Multilingual and user-friendly menu

Portable battery-powered device

Environmentally friendly and safe through usage of test cartridges instead of test gas cans

Multi-stimulus detector tester TF 1001

Same as 805551, but for testing of detectors with smoke and heat sensors. For testing CO consider multi-stimulus detector tester TF 2001 (Part No. 805551).

Technical Data

Battery charging

Heat detector response threshold

Application temperature

Storage temperature

Air humidity

75-90 minutes up to 90°C adjustable up to 100°C

5 °C ... 45 °C

-10 °C ... 50 °C

< 85 % (non-condensing)

Detector tester kit TF 1001 consists of:

Testing head, smoke capsule, 2 Ni-MH battery packs, charger

Accessories

805552 Smoke capsule for multi-stimulus detector tester 805550/51

060426 Plastic telescopic extension

060427 Plastic telescopic rod

060431 Spare battery baton

Smoke

Heat

CO

Menu Status

Example of testing with only one stimuli

Smoke 1

Heat 1

CO

Menu Status

Example of a simultaneous testing

(smoke + heat at the same time)

Smoke 1

Heat 2

CO 3

Menu Status

Example of sequential testing (all criteria successively)

Smoke 1

Heat 1

CO 2

Menu Status

Example of combination of simultaneous and sequential testing)

Selection of different test criteria displayed

1

805552 Smoke capsule for multi-stimulus detector tester 805550/51

Replacement smoke capsule (Testifire TS3) for the testing of smoke detectors series IQ8Quad and

9x00 with optical and/or ionization sensors. Suitable for the multi-stimulus detector tester Part No.

805550/51.

Features

Non-flammable, non-toxic materials

Production of test gas only during the testing

Does not cause any residue in the sensor chamber

Suitable for optical and ionization detectors

No test gas storage under pressure – no dangerous goods

More productivity than the spray can

92 www.hls-austria.com

Automatic Detectors Accessories

1

805553

Features

Non-flammable CO activating material

Generation of small amounts of CO

Generation of CO during testing only

No storing of pressurized CO - no dangerous goods

More productivity than the spray can

1

805582

CO capsule for multi-stimulus detector tester 805551

Replacement CO capsule (Testifire TC3) for the testing of detectors with carbon monoxide sensors

(CO). Especially suited for the OTG multisensor fire detector (CO) IQ8Quad with isolator (Part No.

802473). Suitable for the multi-stimulus detector tester Part No. 805551.

The OTG multisensor fire detector (CO) IQ8Quad with isolator (Part No. 802473) is generally tested either

-with the test gas Part No. 060430.10, suitable for the smoke detector tester Part No.

805582, or

-with Part No. 805552, suitable for the multi-stimulus detector tester Part No. 805551.

The Part No. 802473 is VdS-approved as a smoke detector, the CO test gas is required for the additional triggering of the electrochemical CO gas cell.

Smoke detector tester

The smoke detector tester is designed for electric function control for the IQ8Quad and series 9x00 detectors. After an aerosol has been released, the operation capacity of the measuring chamber can be tested by using the transceiver. The smoke detector tester is adapted to the rod (Part No.

060427).

The telescopic rod is not supplied as standard.

Accessories

060426 Plastic telescopic extension

060427 Plastic telescopic rod

1

805583

1

805584

CO test gas for smoke detector tester 805582

Test gas for testing carbon monoxide CO-detectors. Specifically designed for the OTG multisensor fire detector (CO) IQ8Quad with isolator (Part No. 802473), suitable for smoke detector tester Part

No. 805582.

Technical Data

Content 250 ml (per bottle)

The OTG multisensor fire detector (CO) IQ8Quad with isolator (Part No. 802473) should only be tested in connection with test gas Part No. 060430.10 suitable for smoke detector tester

Part No. 805582. Detector Part No. 802473 has been approved as smoke detector by VdS and the CO test gas is used to additionally trigger the electrochemical CO-gas cell.

Please take note that this item has to be handled as dangerous goods (aerosols, non- flammable, UN1950)

Test gas for smoke detector tester 805582

For all IQ8Quad, ES Detect and series 9x00 detectors, suitable for smoke detector tester 805582.

Technical Data

Content 250 ml (per bottle)

Also suitable for ionization detector of the 9000, 9100 and 9200 series.

These are considered dangerous goods (aerosols/gases, flammable, UN1950).

Substitute for Item No. 060430.10

8

9

6

7

2

3

4

5

12

13

10

11

14

93

Automatic Detectors

1

805585

Accessories

Smokesabre test gas for smoke detectors

Smokesabre is a test gas and manual testing device in one. The test gas is passed through the extensible pipe, which also serves to increase the range for the detector. Facilitates the triggering of smoke alarms in confined spaces, such as false ceilings/floors and is also applicable to low ceiling heights.

Suitable for all detectors of the series IQ8Quad, ES Detect, 9x00 and smoke extraction systems.

Technical Data

Content

Dimensions

150 ml (per bottle)

L: 193 mm

L: 335 mm (with pulled-pipe)

Also suitable for ionization detector of the 9000, 9100 and 9200 series. These are considered dangerous goods (aerosols/gases, flammable, UN1950).

12 pieces

Application example

94 www.hls-austria.com

Automatic Detectors

1

769080

Accessories

1

060429 Test head for heat detector together with battery and charger

Technical Data

Battery charging

Ambient temperature

Storage temperature

Air humidity

Test head, 2 battery batons, charger

Features

Mains cable is not required for testing

Power supply with rechargeable NiMH battery in the adapter of the telescopic rod

Time based termination of testing after 120 seconds in order to prevent any heat-related damages of the detectors

Detector head is switched off after not being used for 5 minutes

Adjustable inclination angle of detector head for an optimal orientation towards the object which has to be tested

Testing height up to 6 meters with telescopic rod and up to 9 meters with its extension device

Excess-current protection for the battery

Display of operating status of the detector head with Duo-LED (red/green)

Battery can be charged via mains supply or via cigarette lighter in vehicles

Accessories

060426 Telescopic extension

060427 Plastic telescopic rod

060431 Spare battery baton

75-90 minutes (if completely discharged)

5 °C ... 45 °C

-10 °C ... 50 °C

< 85 % (non-condensing)

1

060431 Spare battery baton

Replacement battery pack (NiMH) for test head Part No. 060429 and 805551.

Smoke pellets for testing purposes

Pellets for the generation of dense bright smoke. To charge detectors with smoke for testing purposes and verification of air flow. The pellets are lit with an open flame (e.g. matches, lighter etc.). Extinguishing is not necessary. Please ensure the use of a non-flammable base. After igni tion the pellet will burn to complete ash (without formation of flames).

Without oil

6 pcs. smoke pellets

8

9

6

7

2

3

4

5

12

13

10

11

14

Features

40 sec. burning-time per smoke pellet

18 m³ smoke produced per smoke pellet

95

Notes

96 www.hls-austria.com

Manual Call Points

Large Design (ABS)

Large Design (Aluminum)

Accessories for MCP large design

Small Design (ABS)

Accessories for MCP small design

Special Design

10

11

98-101

102-103

104-107

108-114

115-116

117-122

12

13

14

8

9

6

7

2

3

4

5

97

Manual Call Points Large Design (ABS)

1

133

133 36

Features

Slimline design

Low power consumption

Plug-in connection clamps

Optional terminal clamps

2 x cable entries on top, at the bottom and on the rear panel

Fixing on standard flush mounted installation box

Test function via manual call point service key

Detectors that are not ready for operation can be marked with the "Out of order" label by reversing the enclosed operating front foil

The advanced generation of manual call points with fragile elements meets the latest multicultural requirements of the EN 54 - 11 standards as type B (double action). The elegant detector housing, available in 5 different RAL colors, is provided with a pictogram, which is easy to comprehend for foreign people, illiterates as well as children.

Depending on individual requirements, optional labeling foils can be used which can easily replace the pictogram without special tools. The triggering element is protected by a pane of glass and is indicated by arrows.

If required, optional labeling foils can be used, which can easily replace the pictogram. The triggering element is protected by a glass pane and is indicated by arrows. The innovative manual call points can be tested by using the service key to activate the triggering mechanism, which is hidden by a faceplate. Clever design structures allow easy installation.

The manual call points consist of a housing and an electronic module, each of the two parts must be ordered separately.

Type B definition - double action in accordance with EN 54-11 § 3.4.2

(Excerpt taken from EN standard):

Manual fire alarm unit, for which the alarm status cannot be set until an alarm is additionally triggered by the user after the fragile element has been broken or its position, has been changed.

Take note, for a LARGE MCP you have to order the electronic module and the MCP housing separately to have a complete MCP.

Not all possible combinations of electronic modules and housings are approved by VdS.

When using the manual call point as a fire detector for manual actuation in compliance with the EN 54-11 standards, a red housing together with the provided pictogram must be used.

When using the manual call point in heat exhaust or extinguishing system areas, the appropriate housing color must be chosen in compliance with the correct standards.

Wago clamps for looping in wires, e.g. type 273-100 (0.5 mm² - 1.5 mm²) or 273-104

(0.75 mm² - 2.5 mm²) can be mounted on the detector base.

MCP out of order

Application example

Easy to maintain the change of condition by turning the operating foil MCP ready for use

98 www.hls-austria.com

Manual Call Points

1

Plastic Housings

Large Design (ABS)

704900

Pictogram according to EN54-11

704901

704902

704903

704904

Housings for electronic module 80490x.

Technical Data

Type of protection

Housing

Installation

Weight

Dimensions

IP 44

ASA plastic surface mount approx. 83 g (w/o electronic module)

W: 133 mm H: 133 mm D: 36 mm

Housing with glass pane (Part No. 704910)

Plastic key (Part No. 769910)

Accessories

704910 Spare glass for manual call points

769910 Plastic spare key

769911 Metal key for large MCP

769916 Service key

704917 Option IP 55 shrink sleeve for large MCP 80490x

704911 Universal foil for large MCP housing ABS

MCP housing large with glass pane, red, similar to RAL 3020

Technical Data

Dimensions W: 133 mm H: 133 mm D: 36 mm

The red manual call point housing is only available with the pictogram (as shown) in compliance with EN 54-11.

Please note that in compliance with EN54-11 the labeling must come with the burning house symbol.

MCP housing large with glass pane, blue, similar to RAL 5015

The Part No. 804902 electronic module in a blue housing complies with the EN 12094-3 and thus can be applied as an electronic stop button for gas extinguishing systems in dry, non- hazardous production sites.

For different use such as application as "HOUSE ALARM" push button, ready-made labels are provided.

Labeling foil set (white) for various international applications.

MCP housing large with glass pane, yellow, similar to RAL 1021

The Part No. 804900 or 804901 electronic module in a yellow housing 704902 complies with the EN 12094-3 and thus can be applied as electronic control module for gas extinguishing systems in dry, non-hazardous production sites.

For different use such as application as "HOUSE ALARM" push button, ready-made labels are available.

Labeling foil set (black) for various international applications.

MCP housing large with glass pane, orange, similar to RAL 2011

Labeling foil set (black) for various international applications.

MCP housing large with glass pane, green, similar to RAL 6002

Labeling foil set (white) for various international applications.

10

11

12

13

14

8

9

6

7

2

3

4

5

99

Manual Call Points Large Design (ABS)

1

Electronic Modules - Conventional

1

804900

1

804901

1

804902

Technical Data

Operating voltage

Alarm current @ 9 V DC

No. of detector/zone

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Housing

Weight

Detector specification

Dimensions

8 ... 30 V DC typ. 9 mA

10 detectors per zone (according to VdS)

LED, red max. 2.5 mm² (AWG 26-14)

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP44 (in housing), IP55 (with accessory)

PC ASA plastic approx. 236 g (with housing)

EN 54-11, Type B

W: 133 mm H: 133 mm D: 36 mm

Conventional MCP electronic module

Approval: VdS, CNBOP

With alarm indicator, suitable for connection to a standard detector zone.

Technical Data

Declaration of Performance DoP-20482130701

In combination with the yellow housing (Part No. 704902), the electronic module is approved as an electronic control unit for gas extinguishing systems.

The Part No. 804900 electronic module with yellow housing conforms to the EN 12094-3 standard and can be used as an electronic control unit for gas extinguishing systems in dry, non-hazardous industrial premises.

Conventional MCP electronic module with 2nd microswitch

Approval: VdS, CNBOP

Same as 804900, but with second microswitch with dry contact NC/C (break) or NO/C (make) that is activated when the alarm is triggered.

Technical Data

Contact load

Declaration of Performance

30 V DC / 1 A

DoP-20482130701

In combination with the yellow housing (Part No. 704902), the electronic module is approved as an electronic control unit for gas extinguishing systems.

The Part No. 804901 electronic module with yellow housing conforms to the EN 12094-3 standard and can be used as an electronic control unit for gas extinguishing systems in dry, non-hazardous industrial premises.

Conventional MCP electronic module w/o snap-on function

Approval: VdS with blue housing 704901

Same as 804900, but without snap-on function.

Technical Data

Declaration of Performance DoP-20195130701

This electronic module is only approved as an electric stop push-button for gas extinguishing systems when combined with the blue housing (Part No. 704901). The electronic module

Part No. 804902 with blue housing complies with the EN 12094-3 standard and therefore it can be used as an electric stop push-button for gas extinguishing systems in dry, non- hazardous branches.

In case the manual call point is used as a "house alarm" push-button, pre-printed labels are provided in the manual call point package.

100 www.hls-austria.com

Manual Call Points Large Design (ABS)

1

Electronic Modules for Series IQ8MCP - Addressable

Technical Data

Operating voltage

Quiescent current @ 19 V DC

8 ... 42 V DC approx. 45 μA

Alarm current w/o communication curtain approx. 18 mA

No. of detector/zone

Operation indicator

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Housing

Weight

Detector specification

Dimensions

10 detectors per zone, 127 detectors/loop (according to VdS)

LED, green

LED, red max. 2.5 mm² (AWG 26-14)

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP 44 (in housing), IP 55 (with accessory)

PC ASA plastic approx. 236 g (in housing)

EN 54-11, type B

W: 133 mm H: 133 mm D: 36 mm

1

804905 IQ8MCP electronic module with isolator

Approval: VdS, CNBOP

Addressable electronic module suitable for use in the esserbus and powered loop with alarm latch and alarm indicator. Optional connection for conventional MCP. Without BUS connection, the detector operates as conventional MCP. Built-in loop isolator in the manual call point. An external detector zone (D-line) could be connected with up to ten conventional manual call points (internal

Alarm resistor for each detector 1 KOhm) - e.g. Part No. 804900 or 804901 to this IQ8 manual call point model and configure required operation with tools 8000. When an alarm is triggered the address and the programmed additional text of the MCP IQ8 to which the conventional zone is connected are displayed automatically. Cable length of the D-line max. 500 meters!

Technical Data

Type of protection

Detector specification

Declaration of Performance

IP44 (in housing), IP55 (with accessory)

EN 54-11, typ B

DoP-20489130701

1

804906 IQ8MCP electronic module w/o isolator, with relay

Approval: VdS

Addressable electronic module with floating contacts of a changeover relay NC/C (break) or NO/C

(make), suitable for use in the esserbus and powered loop with alarm latch and alarm indicator.

Without BUS connection, the detector operates as conventional MCP.

Without built-in loop isolator and optional connection for conventional MCP.

The relay output is activated with the triggering of this detector. The relay output can be programmed in the System 8000 and IQ8Control FACP customer data as a control group.

Technical Data

Contact load relay

Declaration of Performance

30 V DC / 1 A

DoP-20488130701

10

11

12

13

14

8

9

6

7

2

3

4

5

101

Manual Call Points Large Design (Aluminum)

Both housing and electronic module need to be ordered. Not all possible combinations of electronic modules and housings are approved by VdS. The approved combinations are listed in the VdS approval field for the corresponding electronic module.

1

Aluminum Die-Cast Housings

Technical Data

Type of protection

Material

Installation

Weight

Dimensions

IP43, IP54 with kit 704070 aluminum, die-cast surface mount approx. 600 g

W: 126 mm H: 126 mm D: 42 mm

Housing with glass pane and plastic key, fixing material, 1 x multilingual "Out of order" paper insert, 2 x cable entries, 2 x dummy plugs

Accessories

704910 Spare glass for manual call points

769910 Plastic spare key

769911 Metal key for large MCP 80490x

1

704801.10

MCP housing ALU, large, glass pane

Printed with pictograms in accordance with EN 54-11.

Technical Data

Color red, similar to RAL 3000

704804

704854

MCP housing with glass, print: house alarm

Technical Data

Color red, similar to RAL 3000

MCP housing with glass, print: house alarm

Technical Data

Color blue, similar to RAL 5009

1

Neutral Housings w/o Print

1

704870 MCP housing ALU, large, neutral

Technical Data

Color yellow, similar to RAL 1018

102 www.hls-austria.com

Manual Call Points Large Design (Aluminum)

Electronic Modules for Series 9000

1

704477.10

Conventional MCP electronic module with 2nd micro-switch, Series 9000

Approval: VdS with housing 704801.10

Printed with pictograms in accordance with EN 54-11

Technical Data

Operating voltage

Alarm current @ 9 V DC

Contact load

No. of detector/zone

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Weight

Detector specification

Dimensions

Declaration of Performance

8 ... 30 V DC typ. 9 mA

30 V DC/1A

10 detectors per zone (according to VdS)

LED, red

0.6 ... 1.5 mm²

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP43 (with housing)

IP 54 (with housing and option 704070) approx. 100 g (w/o housing)

EN 54-11, type B

W: 95 mm H: 95 mm D: 25 mm

DoP-20478130701

Electronic Module for Series 9200

1

804473.10

Addressable MCP electronic module with zone isolator, Series 9200

Approval: VdS with housing 704801.10

Printed with pictograms in accordance with EN 54-11

Technical Data

Operating voltage

Quiescent current @ 19 V DC

8 ... 42 V DC approx. 45 μA

Alarm current @ 9 V DC typ. 9 mA

Alarm current w/o communication curtain approx. 18 mA

Contact load

No. of detector/zone

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Weight

Detector specification

Dimensions

Declaration of Performance

30 V DC/1A

10/zone, 127/loop (VdS)

LED, red

0.6 mm ... 1.5 mm²

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP43 (with housing)

IP 54 (with housing and option 704070) approx. 100 g (w/o housing)

EN 54-11, type B

W: 95 mm H: 95 mm D: 25 mm

DoP-20481130701

10

11

12

13

14

8

9

6

7

2

3

4

5

103

Manual Call Points

1

704910

1

701040

1

769921

Accessories for MCP large design

Spare glass pane for MCP housing 70490x, 7048xx und 761694

Spare glass pane for detector housings large design Part No. 70490x, 7048xx, 761694 and

761697 in compliance with EN 54-11.

Technical Data

Dimensions

10 pcs

W: 80 mm H: 80 mm

Spare glass pane red for MCP housings 7047xx and 7048xx

Spare glass pane, printed with red circle segments (similar to RAL 3000) for all Part No. 7047xx and Part No. 7048xx manual call points (large design).

Technical Data

Dimensions W: 80 mm H: 80 mm

10 Multilingual "Out of order" paper labels are included.

10 pcs

"Out of order" sign, multilingual for 7047xx, 7048xx and 70490x

Plastic sign for all Part No. 7047xx, 7048xx and 70490x manual call points (large design).

Technical Data

Dimensions W: 80 mm H: 80 mm

1

704915 Operating foil for large MCP 80490x, neutral

Replacement operating panel foil, neutral without logo, for large design Part No. 80490x manual call points in resistant plastic design. The foil is designed as a double-sided insert. Complementing the standards-compliant symbolism for manual fire alarms according to EN 54-11 (type B), it contains a symbol on the back for the removal from service of the alarm and is easily accessible at all times for possible maintenance operations.The "Out of order" representation occurs via an internationally understandable construction worker symbol and multilingual text.

Technical Data

Material

Dimensions

10 pcs.

PP (0.3 mm)

W: 72 mm H: 75.7 mm

MCP “Out of order”

Application example

Easy to maintain the change of condition by turning the operating foil.

MCP “Ready for use”

104 www.hls-austria.com

Manual Call Points

1

704917

Accessories for MCP large design

Option IP55 shrink sleeve for large MCP 80490x

10 shrink sleeves for clamp terminals to increase protection class to IP55.

10 pcs

IP44

Application example without (IP44) and with (IP55) shrink sleeve

IP55

1

704911

Emergency Stop

Gas extinguishing system

Arrêt d'urgence

Système d'extinction à gaz

PARO EMERGENCIA

Sistema de extinción

PARAGEM EMERGÊNCIA

Sistema de extinção

BLUSSING BLOKKEREN

Knop ingedrukt houden

AMOK-ALARM

POZAR

Front foil with universal text for large MCP ABS, white lettering

Universal, punched foil set (transparent with white imprint) for the labeling field, different from the standard version.

Transparent foil with white lettering.

10 pcs similar image

1

704912

Foil for front face with universal text for large MCP ABS, black lettering

As 704911, but with black imprint.

10 pcs

10

11

12

13

14

8

9

6

7

2

3

4

5

1

704070 IP54 kit for large MCP 7048xx

Cable entries to increase protection class from IP 43 to IP 54 for manual call points in die-cast aluminum housings (Part No. 7048xx).

Technical Data

Material

Color

Cable diameter as shown

PS gray, similar to RAL 7035

6 mm

105

Manual Call Points

1

769910

Accessories for MCP large design

Plastic key for large MCP

Plastic key type D for all manual call points (large design).

Please note that for activating the test functionality of electronic modules (Part No. 80490x), the service key Part No. 769916 is required.

1

769911

1

769916

1

781682

1

781692

Metal key for large MCP

Metal key type D for all detector housings (large design).

Please note that for activating the test functionality of electronic modules (Part No. 80490x), the service key Part No. 769916 is required.

Service key for electronic module (Part No. 80490x)

With this metal service key, the test functionality of the manual call point is activated and reset by authorized persons only.

The key is suitable for all electronic modules with Part No. 80490x from index 05 and yellow locking.

Weather protective cover for MCP housings 7047/48xx, red

Protective housing with protruding roof edge, for all Part No. 7047xx and 7048xx detector housings for increased mechanical protection as well as for protection from bad weather conditions.

Technical Data

Material

Color

Dimensions

PVC red, similar to RAL 3000

W: 135 mm H: 153 mm D: 62 mm

Please mention for the manual call point, large design plastic (e.g. IQ8MCP), the protection cover Part No. 781693 and the related accessories.

Weather protective cover and mounting material

Weather protective cover for MCP housings 7047/48xx, blue

Same as 781682, but blue color.

Technical Data

Color blue, similar to RAL 5009

Weather protective cover and mounting material

106 www.hls-austria.com

Manual Call Points

1

781693

Features

Easy to install

781694

1

781698

1

781699

Accessories for MCP large design

Protective cover for manual call points, German

Technical Data

Ambient temperature

Type of protection

Material

Weight

Dimensions

-40 °C ... 49 °C

IP 44

Polycarbonate approx. 590 g

W: 180 mm H: 260 mm D: 100 mm

This protective cover prevents false alarms, without hampering real alarms. This device consists of a rack and a lid, made of transparent polycarbonate.

It prevents inadvertent activation, vandalism, dust and water from triggering false alarms. The protective cover is suitable for all manual call points.

Accessory for installation

Application example

Protective cover for manual call points, English

Same as 781693, but English.

Surface spacer for protective cover

The spacer is required for surface mount wiring.

Technical Data

Weight

Dimensions

Accessory for installation approx. 510 g

W: 180 mm H: 260 mm D: 50 mm

IP55 kit for protective cover

Mounting kit - self-adhesive sealing kit for protective cover (Part No. 781693, 781694) and an increased protection level from IP 44 to IP 55.

10

11

12

13

14

8

9

6

7

2

3

4

5

Application example

107

Manual Call Points Small Design (ABS)

1

Small Design (ABS)

88

88 7 21

Features

Slimline design

Low power consumption

Plug-in connection terminals (two direction)

Optional terminal terminals

Triple key function (test, open, reset)

Detectors that are not ready for operation can be marked with the "Out of order" label by reversing the enclosed glass pane

The new generation of manual call points meets the latest multi-cultural requirements of the EN 54

- 11 standards as type A (single action). The elegant housing is provided with a pictogram, which can be understood by children as well as in an international context.

Depending on individual requirements, the pictogram can be easily replaced by optional labeling field foils without using additional tools for removal. The actuation field is marked by arrows pointing towards it. The innovative manual call points can be tested by using the key to activate the triggering mechanism, which is hidden by a faceplate. Smart housing and terminal design enables easy installation.

If the glass pane is replaced with the optionally available plastic pane with reset function, the

MCP can be reset from the outside using the key.

For the surface mounting of the MCP the surface mount base Part No. 704980 must be ordered separately, if the cable wasn't laid about a standard flush mount wall socket.

Type a definition - single action in accordance with EN 54-11 § 3.4.1

(excerpt taken from EN standard):

Manual fire alarm unit, for which the alarm status is automatically set (additional alarm triggering is not required) after the fragile element has been broken or its position has been changed.

Compact MCP Versions - Conventional

1

804970 Conventional MCP compact, small, red, glass pane

Approval: VdS, CNBOP

Including housing and alarm indicator. For connection to a conventional detection zone.

Technical Data

Operating voltage

Quiescent current @ 9 V DC

Alarm current @ 9 V DC

No. of detector/zone

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Detector specification

Dimensions

Declaration of Performance

8 ... 30 V DC approx. 0 μA typ. 9 mA

10 detectors per zone (according to VdS) red LED and yellow actuation indicator max. 2.5 mm² (AWG 26-14)

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP43, IP55 with cover 704965

PC ASA plastic red, similar to RAL 3020 approx. 110 g

EN 54-11, type A

W: 88 mm H: 88 mm D: 21 mm

DoP-20486130701

1 x Glass pane 704960

1 x Key 704966

1 x Multilingual paper labels with "Out of order" pictogram.

Accessories

704980 Surface mount housing

108 www.hls-austria.com

Manual Call Points

1

804971

1

804973

Small Design (ABS)

IQ8MCP compact, small, red, with isolator and glass pane

Approval: VdS, CNBOP

Suitable for esserbus and powered loop connection, with soft address coding, alarm latch and alarm indicator. Conventional detectors can be connected to input of the MCP. Without BUS communication, the detector operates as conventional MCP. Detector housing is included.

Built in isolators maintaining loop integrity.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

8 ... 42 V DC approx. 45 μA

Alarm current w/o communication curtain approx. 18 mA

No. of detector/zone

Operation indicator

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Detector specification

Dimensions

Declaration of Performance max. 127 detectors per loop (according to VdS)

LED, green red LED and yellow actuation indicator max. 2.5 mm² (AWG 26-14)

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP43, IP55 with cover 704965

PC ASA plastic red, similar to RAL 3020 approx. 110 g

EN 54-11, type A

W: 88 mm H: 88 mm D: 21 mm

W: 88 mm H: 88 mm D: 57 mm (with surface mount housing)

DoP-20492130701

1 x Glass pane 704960

1 x Key 704966

1 x Multilingual paper labels with "Out of order" pictogram

Accessories

704980 Surface mount housing

IQ8MCP compact, small, red, with resettable element

Approval: VdS

Same as 804971, but with plastic triggering element, which supports easy reset after an alarm has been triggered without having to replace the broken element (glass pane).

Typically applied in nursery, clean rooms as for example in food processing industries.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

8 ... 42 V DC approx. 45 μA

Alarm current w/o communication curtain approx. 18 mA

No. of detector/zone

Operation indicator

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Detector specification

Dimensions max. 127 MCP per loop

LED, green red LED and yellow actuation indicator max. 2.5mm² (AWG 26-14)

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP43 (in housing)

ASA plastic red, similar to RAL 3020 approx. 110 g

EN 54-11, type A

W: 88 mm H: 88 mm D: 21 mm

W: 88 mm H: 88 mm D: 57 mm (with surface mount housing)

1x Plastic operating panel 704964

1x Key 704966

1x Multilingual paper insert with "Out of order" pictogram included

Accessories

704980 Surface mount housing

10

11

12

13

14

8

9

6

7

2

3

4

5

109

Manual Call Points Small Design (ABS)

1

804961

Features

High IP protection class IP66

Integrated loop isolator

Triple key function (test, open, reset)

Plug-in connection clamps

Detectors that are not ready for operation can be marked with the "out of order" label by reversing the enclosed glass pane

IQ8MCP compact IP 66, small, red, with isolator glass pane

Approval: G 205132

Suitable for esserbus and powered loop connection, with soft address coding, alarm latch and alarm indicator. Without BUS communication, the detector operates as conventional MCP. Detector housing, surface mount housing and transparent cover are included.

Due to the high IP protection IP66 suitable for use in humid areas. Surface mount housing is provided with knock-out cable entries for M20 cable glands (option) for simplified installation.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Alarm current @ 9 V DC

No. of detector/zone

Operation indicator

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Detector specification

Dimensions

8 ... 42 V DC approx. 45 μA typ. 18 mA

10 detectors / group; 127 detectors / ring (according to VdS)

LED, green

LED, red and yellow flag max. 1,5 mm² (AWG 30-14)

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP66

PC-ASA plastic red, similar to RAL 3020 approx. 250 g

EN 54-11, type A

W: 88 mm H: 88 mm D: 57 mm (with surface mount housing)

1 x Spare glass 704960

1 x Plastic spare key 704966

1 x transparent cover

1 x Surface mount housing

Example (optional fittings)

110 www.hls-austria.com

Manual Call Points

1

Plastic Housings

Small Design (ABS)

704950

Pictogram according to EN54-11

704951

704952

704953

704954

Housings for electronic modules Part No. 80495x.

Technical Data

Type of protection

Housing

Installation

Weight

Dimensions

1 x Key 704966

IP 43, IP 55 with 704965

PC ASA plastic housing surface mount approx. 33 g

W: 88 mm H: 88 mm D: 21 mm

Housing for small MCP, red, similar to RAL 3020

Technical Data

Declaration of Performance DoP-20492130701

The red manual call point housing is available only with the pictogram (as shown) according to EN 54-11.

Please note that according to EN54-11, the label for the MCP must include the symbol of the burning house.

Housing for small MCP, blue, similar to RAL 5015

Labeling foil set (white) for various international applications.

Housing for small MCP, yellow, similar to RAL 1021

Labeling foil set (black) for various international applications.

Housing for small MCP, orange, similar to RAL 2011

Labeling foil set (black) for various international applications.

Housing for small MCP, green, similar to RAL 6002

Labeling foil set (white) for various international applications.

10

11

12

13

14

8

9

6

7

2

3

4

5

111

Manual Call Points Small Design (ABS)

1

Surface Mount Housings

The surface mount housing serves as cable entry for surface mount cabling. With integrated support for shielding.

Technical Data

Dimensions

Mounting material

W: 88 mm H: 88 mm D: 36 mm

704980

704981

704982

704983

Surface mount housing for small MCP, red, similar to RAL 3020

Red, for manual call points Part No. 804970, 804971 and 804973, for small design electronic modules Part No. 804950/51, 804955/56 with housing Part No. 704950.

Surface mount housing for small MCP, blue, similar to RAL 5015

Blue, for small design electronic modules Part No. 804950/51, 804955/56 with housing Part No.

704951.

Surface mount housing for small MCP, yellow, similar to RAL 1021

Yellow, for small design electronic modules Part No. 804950/51, 804955/56 with housing Part No.

704952.

Surface mount housing for small MCP, orange, similar to RAL 2011

Orange, for small design electronic modules Part No. 804950/51, 804955/56 with housing Part No.

704953.

112 www.hls-austria.com

Manual Call Points Small Design (ABS)

Electronic Modules - Conventional

1

804950 Conventional MCP electronic module

Approval: VdS

With alarm indicator, for the connection to a standard detector zone.

Technical Data

Operating voltage

Quiescent current @ 9 V DC

Alarm current @ 9 V DC

No. of detector/zone

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Weight

Detector specification

Dimensions

Declaration of Performance

8 ... 30 V DC approx. 0 μA typ. 9 mA max. 10 detectors per loop (as per VdS)

LED, red and yellow flag max. 2,5 mm² (AWG 26-14)

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP 43 (in Housing), IP 55 with cover 704965 approx. 78 g

EN 54-11, type A

W: 88 mm H: 88 mm D: 21 mm

W: 88 mm H: 88 mm D: 57 mm (with surface mount housing)

DoP-20486130701

1 x Glass pane 704960

1 x Multilingual paper labels with "Out of order" pictogram

1

804951 Conventional MCP electronic module, with 2nd micro-switch

Approval: VdS

Same as 804950, but with second microswitch with dry contact NC/C (break) or NO/C (make) that is activated when the alarm is triggered.

Technical Data

Operating voltage

Quiescent current @ 9 V DC

Alarm current @ 9 V DC

Contact load

No. of detector/zone

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Weight

Declaration of Performance

8 ... 30 V DC approx. 0 μA typ. 9 mA

30 V DC/1 A max. 10 detectors per loop (as per VdS)

LED, red and yellow flag max. 2,5 mm² (AWG 26-14)

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP 43 (in housing), IP 55 with cover 704965 approx. 78 g

DoP-20485130701

10

11

12

13

14

8

9

6

7

2

3

4

5

113

Manual Call Points Small Design (ABS)

Electronic Modules - Addressable

1

804955 IQ8MCP electronic module

Approval: VdS

Same as 804971, but without housing.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

8 ... 42 V DC approx. 45 μA

Alarm current w/o communication curtain approx. 18 mA

No. of detector/zone

Operation indicator

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Weight

Detector specification

Dimensions

Declaration of Performance max. 127 detectors per loop (as per VdS)

LED, green red LED and yellow actuation indicator max. 2.5 mm² (AWG 26-14)

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP43 (in housing), IP 55 with cover 704965 approx. 78 g

EN 54-11, type A

W: 88 mm H: 88 mm D: 21 mm

DoP-20492130701

1 x Glass pane 704960

1 x Multilingual paper labels with "Out of order" pictogram

1

804956 IQ8MCP electronic module w/o isolator, with relay

Approval: VdS

Same as 804955, but with relay and without loop isolator or connection possibility for standard manual call points. The relay output is activated by the triggering of this detector. The relay output can be programmed in the IQ8Control and System 8000 FACP customer data as a control group.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Alarm current w/o communication curtain approx. 18 mA

Contact load

No. of detector/zone

Operation indicator

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Weight

8 ... 42 V DC approx. 45 μA

30 V DC / 1 A max. 127 detectors per loop (as per VdS)

LED, green

LED, red and yellow flag max. 2.5 mm² (AWG 26-14)

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP43 (in housing), IP 55 with cover 704965 approx. 78 g

114 www.hls-austria.com

Manual Call Points

1

704960

1

704975

1

704964

Accessories for MCP small design

Spare glass pane for small MCP, EN54

Spare glass pane with white stick-on foil and printed pictogram in compliance with EN 54-11 (type

A). Suitable for small MCPs.

Technical Data

Dimensions W: 56 mm H: 49.5 mm D: 1.85 mm

To indicate that the detector is "Out-of-order" the operator has a corresponding pictogram on the reverse side.

10 pcs

Spare glass pane for small MCP, EN54, neutral

Spare glass pane with white stick-on foil and printed with pictogram according to EN 54-11 (type

A), for small manual call points, without logo.

Technical Data

Dimensions W: 56 mm H: 49.5 mm D: 1.85 mm

To indicate that the detector is "Out-of-order" the operator has a corresponding pictogram on the reverse side.

10 pcs

Resettable element for small MCP

Resettable, white plastic, for small manual call points. Typically applied, for instance, in food processing industries or in clean rooms.

Technical Data

Material

Dimensions

Declaration of Performance

ABS

W: 56 mm H: 49.5 mm D: 1.85 mm

DoP-20492130701

To indicate that the detector is "Out-of-order" the operator has the same pictogram as shown above on the reverse side.

10 pcs

Release the MCP

Application example

Released

MCP

2

1

Resetting the MCP

MCP ready for operation

10

11

12

13

14

8

9

6

7

2

3

4

5

115

Manual Call Points

1

704965

Accessories for MCP small design

Protective kit for MCP and TAL, transparent

Transparent, suitable for small MCPs. The cover serves as a protection to prevent inadvertent activation and to protect from high humidity.

Technical Data

Type of protection

Material

Cover and two neoprene seals

IP55 plastic cover, transparent

1

704966

1

704967

Application example: Manual call point with mounted cover

Plastic spare key for small MCP

Plastic key, red, suitable for small manual alarm units.

10 pcs

Mounting frame for small MCP, red and white

The mounting frame is useful for mounting MCPs on different international flush mount boxes.

Technical Data

Color

Dimensions red, similar to RAL 3020 white, similar to RAL 9010

W: 132 mm H: 132 mm D: 8 mm

2 x Fastening screws are included (red and white)

or

Application example: Mounting frame with small MCP

116 www.hls-austria.com

Manual Call Points

1

761694

1

W1A-R1K0SG-U007-01

Features

Sealed to IP 67

Unique ‘plug and play’ installation concept

Anti-tamper facility

Enhanced aesthetics and compact design

Approved to EN 54-11

Special Design

Addressable MCP, IP66

Approval: G 209190

Addressable manual call point in conformity with EN 54-11 type B with loop isolator for manually triggering fire alarms or hazard alarms. For outdoor application or application in damp environments.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

No. of detector/zone

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

Declaration of Performance

8 ... 42 V DC approx. 45 μA max. 10 (according to VdS), 127 / loop

LED, red max. 1.5 mm²

-20 °C ... 70 °C

-25 °C ... 75 °C

< 95 % (non-condensing)

IP66

PC-plastic red, similar to RAL 3000 approx. 475 g

W: 135 mm H: 135 mm D: 61 mm

DoP-20882130701

Please take note, our Part No. 769910 and 769911 can be used as spare keys.

To indicate that the detector is "Out-of-order" the operator has to insert the paper inlay, which has a corresponding pictogram and wording.

1 x Glass 704910

1 x Key and “Out of order” sign or “Außer Betrieb”

Accessories

704910 Spare glass for MCP

769910 Plastic key for large MCP

769911 Metal key for large MCP

Manual call point IP67, small housing, red

The outdoor MCP is an IP 67 sealed product. The enhanced environmental protection allows the unit to be installed in many external environments where water and dirt are likely to be present, making it a true waterproof and outdoor product.

The manual call point has a unique ‘plug and play’ concept designed specifically to reduce installation time. The product utilizes a special terminal block, where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. The housing is supplied with three standard 20mm knock outs for cable entries, accom modating all types of surface wiring installations.

The MCP also helps to preserve the integrity of the overall system as illegal removal of the product lid will result in the call point operating and the system triggering an alarm.

Technical Data

Application temperature

Storage temperature

Air humidity

Type of protection

Material

Weight

Detector specification

Dimensions

1 x Cable gland included

-30 °C ... 70 °C

-30 °C ... 70 °C

< 95 % non condensing

IP 67

PC/ABS approx. 240 g

EN 54-11

W: 97.5 mm H: 93 mm D: 71 mm

Accessories

MUS155 Spare glass pane (5 pcs)

SC070 Spare key

PS200 Plastic cover

10

11

12

13

14

8

9

6

7

2

3

4

5

117

Manual Call Points Special Design

Manual Call Points Intrinsically Safe

1

W1A-R1K0SG-E019-81

Features

Sealed to IP67

Unique ‘plug and play’ installation concept

Anti-tamper facility

Enhanced aesthetics and compact design

Approved to EN 54-11

Ex manual call point IP67, small housing, red

Approval: LPCB, ATEX

The Ex MCP is built especially for installation in hazardous areas. It is intended for outdoor use within intrinsically safe systems using suitable barriers.

The outdoor MCP is an IP 67 sealed product. The enhanced environmental protection allows the unit to be installed in many external environments where water and dirt are likely to be present, making it a true waterproof and outdoor product.

The manual call point has a unique ‘plug and play’ concept designed specifically to reduce installation time. The product utilizes a special terminal block, where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. The housing is supplied with three standard 20mm knock outs for cable entries, accom modating all types of surface wiring installations.

The MCP also helps to preserve the integrity of the overall system as illegal removal of the product lid will result in the call point operating and the system triggering an alarm.

Technical Data

Application temperature

Storage temperature

Air humidity

Type of protection

Material

Weight

Detector specification

ATEX certificate

Ex-category

Dimensions

-25 °C ... 70 °C

-25 °C ... 70 °C

< 93 % ±3% non condensing

IP67

PC/ABS approx. 350 g

EN 54-11

Sira 06ATEX2131X

II 1GD EEXiaIICT

W: 97.5 mm H: 93 mm D: 71 mm

! Attention – cable glands not included in delivery.

Accessories

706031 Spare glass plane (5 pcs)

706032 Spare key

706033 Plastic cover

764744 Ex-barrier

118 www.hls-austria.com

Manual Call Points Special Design

1

804960.EX

Features

High IP protection class IP66 & IP67

Triple key function (test, open, reset)

Plug-in terminals

“Out of Order” indication of an inoperative alarm by flipping over the glass pane

Small Conventional MCP Ex (i) IP 66/67, red with glass pane

Approval: G 214115

The small compact version has detector housing, surface mount housing, transparent cover, and alarm indicator. For connection to a conventional zone for use in ex-areas. Suitable for use in damp rooms thanks to the high IP 66/67 IP protection. Surface mounting housing is provided with break-out cable entries for M20 cable glands (optional) for easy installation.

Technical Data

Data according to ATEX:

Max. Input Voltage (Ui)

Max. Input current (Ui)

Ambient temperature (Ta)

EC-type examination certificate

Ex-category

Explosion protection

Specification

Common technical data:

Operating voltage

Alarm current @ 9 V DC

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Material

Weight

Color

Detector specification

Dimensions

Declaration of Performance

21 V DC

252 mA

-20 °C ... 70 °C

TÜV 14 ATEX 150860

II 2G (with Ex barrier Part-No. 764744 / 804744)

Ex ib IIC T4 Gb

EN 60079-0:2012 + A11:2013 / -11:2012

8 ... 30 V DC typ. 9 mA red LED and yellow actuation indicator max. 1,5 mm² (AWG 30-14)

-20 °C ... 70 °C

-20 °C ... 70 °C

< 95 % (non condensing)

IP66, IP67

PC ASA plastic approx. 255 g red, similar to RAL 3020

EN 54-11 : 2001 + A1:2005, Typ A

W: 88 mm H: 88 mm D: 63 mm (w. surface mount h.)

DoP-21415141219

Use M20 cable glands with 15 mm connecting thread length and sealing ring, e.g. blueglobe by Pflitsch

(cable gland Part No.: bg 820PA/sealing ring Part No.: DRF 220).

For detailed information on installation and operation, see documentation Part No. 798920.

For operation with standard groups ex-barrier Part No. 764744 must be used in zone 1 and zone 2!

1 x glass pane 704960

1 x key 704966

1 x surface mounting housing

1 x transparent cover

10

11

12

13

14

8

9

6

7

2

3

4

5

119

Manual Call Points

1

804920.EX

Features

High IP protection up to IP55

Plug-in terminals

Standard keys with double function: Open, reset

Service key with triple function: Test, open, reset

"Out of Order" marking an inoperative detector by turning the enclosed operating front foil

Special Design

Large Conventional MCP Ex (i) IP 66/67, red with glass pane

Approval: G 214113

Standard large intrinsically safe MCP, consisting of electronic module and detector housing, for connection to a conventional zone, especially for use in hazardous areas. Suitable due to the high

IP protection up to IP 55 for use in damp rooms.

Technical Data

Data according to ATEX:

Max. Input Voltage (Ui)

Max. Input current (Ui)

Ambient temperature (Ta)

EC-type examination certificate

Ex-category

Explosion protection

Specification

Common technical data:

Operating voltage

Alarm current @ 9 V DC

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Material

Weight

Color

Detector specification

Dimensions

Declaration of Performance

21 V DC

252 mA

-20 °C ... 70 °C

TÜV 14 ATEX 150860

II 2G (with Ex barrier Part-No. 764744 / 804744)

Ex ib IIC T4 Gb

EN 60079-0:2012 + A11:2013 / -11:2012

8 ... 30 V DC typ. 9 mA

LED, red max. 1,5 mm² (AWG 30-14)

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non condensing)

IP44, IP55 with shrink sleeve

PC ASA plastic approx. 236 g (in housing) red, similar to RAL 3020

EN 54-11: 2001 + A1:2005, Typ A

W: 133 mm H: 133 mm D: 36 mm

DoP-21415141219

For detailed information on installation and operation, see documentation part no. 798920. For operation with standard groups ex-barrier item no. 764744 must be used in zone 1 and zone 2!

1 x glass pane 704960

1 x key 769910

1 x Manual call point housing, red

1 x IP 55 shrink sleeve

120 www.hls-austria.com

Manual Call Points

1

761697

Special Design

Explosion-proof conventional MCP, IP66

Approval: VdS, PTB 97 ATEX 3197

Explosion-proof encapsulated conventional manual call point for hazardous areas in conformity with EN 54-11 Type B for the manual actuation of a fire alarm and/or a hazard alarm, as a detector for usage in explosion-hazardous areas both inside and outside.

The operating front foil has been designed as a double-sided insert. Complementary to the symbolism conforming to the standards for manual call points in compliance with EN 54-11 (Type B), it has a symbol and multilingual text on the back for the "Out of order" status of the detector and is always available for possible maintenance work.

The labeling foil of the manual call point also has a double-sided design. In compliance with EN

54-11, it contains the standard symbol of a burning house. On the back, the symbol is supplemented with the word “FIRE” (multilingual).

Technical Data

Data according to ATEX:

Ex-category

Explosion protection

Common technical data:

Operating voltage

Alarm current

No. of detector/zone

Circuit

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Detector specification

Dimensions

II 2G

Ex e d mb IIC T6, T5

12 ... 24 V DC approx. 9 mA max. 10 detectors per Zone (according to VdS)

1 k/10 k (internal)

0.6 mm ... 4 mm²

-55 °C ... 65 °C

-55 °C ... 85 °C (T5)

-55 °C ... 85 °C

< 95 % (non-condensing)

IP66

Glass fiber reinforced polyester resin red, similar to RAL 3000 approx. 1.8 kg

DIN 14678 Form K

W: 136 mm H: 138 mm D: 88 mm

Please note, an Allen key (size 4) is needed for opening and resetting the MCP, and is not included in the scope of delivery.

1 x Glass pane 704910

1 x Kit of double-sided operating front foil (with "Out of order" on the back)

1 x Kit of double-sided labeling foil (multilingual)

Accessories

704910 Spare glass pane for MCP housings

Out of

Order

Außer

Betrieb

10

11

12

13

14

8

9

6

7

2

3

4

5 fuera de servicio hors service

POZAR

FEUER

FIRE

FEU

FUEGO

Feuerwehr

Operating front foils and labeling foils

121

Manual Call Points

PS200 Transparent cover for MCP

Spare transparent cover for addressable manual points.

Special Design

SC070 Spare keys pack for MCP

10 spare keys for addressable MCP. The MCP key is used to open, reset and test the MCPs.

10 pieses

122 www.hls-austria.com

Transponders / Input & Output Modules

esserbus

8

9

6

7

2

3

4

5

10

11

124-135

12

13

14

123

Transponders / Input & Output Modules esserbus

Professional fire detection systems are expected to provide more than reliable fire detection and signaling alarms to the fire brigade. Over time, the continuous progress in technical units has led to many improvements in monitoring and control systems. At the same time the specifications of the

European standards are becoming more and more demanding. These complex requirements towards control and monitoring of individual parts of a unit was reason enough to redesign our assortment of esserbus transponders.

Essentially the new assortment consists of the so-called "alarm transponder" which is used for both the connection of non-addressable detectors (point-type detectors, manual detectors and special detectors) as well as for the operation of conventional alarm signaling devices (signaling devices, signal flasher and combination alarm signaling devices). Monitoring of the lines in accord ance with the latest standards is ensured via "EOL modules" (end-of-line modules).

The second part is formed by the "FCT" (fire control transponder) and the IQ8TAL being loop- powered input and output transponders with a contact input and a floating relay output for monitoring of contacts and transmission of technical alarms for equipment monitoring.

These modules with low power consumption are for interfacing to other disciplines which are not a part of the fire detection system itself. Thanks to their intelligent concept they significantly expand the range of monitoring and control functions as part of the building management.

Take note, esserbus transponders need ONLY ONE loop address per device, anyway how much inputs or outputs are switched - i.e. in case that more than one input/output per device is needed, this feature reduces the quantity of transponders needed!

124 www.hls-austria.com

Transponders / Input & Output Modules esserbus

1

808623 esserbus alarm transponder, 4 IN/2 OUT with isolator

Approval: VdS

Features

Only one loop address is needed per transponder

Digital inputs

Integrated loop isolator

Conventional connection of standard fire detectors and signaling devices

Loop monitoring in compliance with EN 54-13

Integrated loop isolator

Programmable relay outputs

Programmable relay reset function

Max. 100 transponders per FACP

Max. 31 transponders per loop

Max. 127 detector zones per loop

Detector numbers per zone input of the transponder:

Max. 30 conventional detectors (without SOC)

Max. 10 conventional detectors (with SOC)

Max. 10 Manual call points (MCP)

Max. 10 Technical Alarm Modules (TAM)

Max. 5 audible alarm devices per each output

(observe calculation table in tools 8000)

The esserbus transponder functions as a device on the multi-functional primary line. The connection of four zones with automatic standard detectors, manual call points (non-addressable) as well as special detectors is possible. In addition, two programmable relay outputs are also available.

Both relay outputs of the transponder may be used to reset a connected third-party detector. The reset function relates to the corresponding special detector, e.g. by switching the appropriate input to GND or by a short interruption of the detectors supply voltage. Therefore the control mode

>Reset-Relay< as well as the desired relay operation mode (normally closed or open) must be configured with the programming software tools 8000 from V1.15 and above. The relay output will be activated for the selected reset time (1 to 14 seconds) if the assigned input (G1 for relay 1/G2 for relay 2) of the transponder is reset. Refer to the detectors manual for the required reset time.

Monitoring via the EOL terminating devices (Part No. 808624/808626) is required for the connection of fire detectors and for the controlling of alarm signaling devices. The enclosed resistors can be used to connect the floating contacts.

The esserbus alarm transponder requires an external voltage supply. An optional Voltage

Converter (Part No. 781336) is also required for 12V DC operation. The esserbus alarm transponder external voltage supply can be monitored during operation.

The EOL-I terminating device (Part No. 808626) must be used for standard-compliant monitoring of detector zone inputs. The EOL-O (Part No. 808624) must be used for standard-compliant monitoring of connected alarm signaling devices.

Technical Data

Operating voltage

Quiescent current @ 12 V DC

Current consumption

Contact load relay

Ambient temperature

Storage temperature

Air humidity

Type of protection

Weight

Dimensions

Declaration of Performance

Installation accessory pack

10 ... 28 V DC approx. 12 mA max. 120 mA @ 12 V DC

30 V DC / 1 A

-10 °C ... 50 °C

-25 °C ... 75 °C

< 95 % (non-condensing)

IP 40 (in housing) approx. 28 g

W: 82 mm H: 72 mm D: 20 mm

DoP-21057130701

Accessories

788603.10 Module housing for snap-on mounting rail

788600 Housing surface mount, gray

788650.10 Housing surface mount, white

788601 Housing flush mount, gray

788651.10 Housing flush mount, white

788612 Loop isolator for transponder

781336 DC/DC converter output voltage

808624 EOL-O Terminating device

808626 EOL-I Terminating device

10

11

12

13

14

8

9

6

7

2

3

4

5

125

Transponders / Input & Output Modules esserbus

1

808623.10

esserbus transponder for UniVario with isolator

Approval: VdS

Features

Only one loop address is needed per transponder

Digital input

Loop monitoring in compliance with EN 54-13

Integrated loop isolator

Programmable relay outputs

Programmable relay reset function

Max. 100 transponders per fire alarm control panel

Max. 31 transponders per loop

Max. 127 detector zones per loop

Detector numbers per zone input of the transponder:

Max. 30 conventional detectors (without SOC)

Max. 10 conventional detectors (with SOC)

Max. 10 Manual call points

Max. 10 Technical Alarm Modules (TAM)

Max. 5 audible alarm device (observe calculation table in tools 8000)

The interface connects max. 2 industrial sensors from the UniVario product range. These sensors are supplied with energy via the 9 V DC group voltage input. For meeting the standard requirements of monitoring, an EOL-UV terminal element is connected to the sensor base of the UniVario sensor. The interface requires external voltage supply. Additionally, two optionally monitored relay outputs are available.

Technical Data

Operating voltage

Quiescent current @ 12 V DC

Current consumption

Contact load relay

Ambient temperature

Storage temperature

Air humidity

Type of protection

Weight

Dimensions

Declaration of Performance

Installation Accessory Pack

10 ... 28 V DC approx. 12 mA max. 120 mA @ 12 V DC

30 V DC / 1 A

-10 °C ... 50 °C

-25 °C ... 75 °C

< 95 % (non-condensing)

IP 40 (in housing) approx. 28 g

W: 82 mm H: 72 mm D: 20 mm

DoP-21057130701

Accessories

788603.10 Module housing for snap-on mounting rail

788600 Housing surface mount, gray

788650.10 Housing surface mount, white

788601 Housing flush mount, gray

788651.10 Housing flush mount, white

788612 Loop isolator for transponder

781336 DC/DC converter output voltage

808626 EOL-I Terminating Device

126 www.hls-austria.com

Transponders / Input & Output Modules esserbus

1

808621

Features

Module for controlling and monitoring fire protection devices

Power supply via the field bus esserbus

Output switching load up to 230 V AC / 16 A

Programmable run-time monitori

Configurable fail safe functionality

Manual output activation at transponder

Robust IP 65 protected surface mount housing

Silicone cable entries for fast installation

esserbus transponder IQ8FCT LP

Approval: VdS G 209138

The IQ8FCT LP is used to control and monitor external fire control devices like fire dampers or as a technical alarm component (TAL) to monitor an external contact and control external load.

The transponder is connected on the esserbus/esserbus-PLus loop of fire control system FlexES

Control and IQ8Control.

FCT functionality

In this function a fire control device e.g. fire damper is connected to the relay output of the IQ8FCT

LP and controlled according to the programming with configured runtime. Via the input the end positions of this external device are monitored. If the external device is leaving the set position e.g. at a power loss or is stuck a failure is recognized and indicated at the IQ8FCT LP and the fire control panel. The IQ8FCT LP is also equipped with configurable fail save functionality.

If enabled, a communication loss with control panel results in automatic selfactivation of relay output.

TAL functionality

Here an external contact can be connected and monitored via the input of the IQ8FCT LP. In case of an activation of this contact, the address and programmed additional text of the corresponding technical alarm module IQ8FCT LP will be displayed.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Relay contact

14 ... 42 V DC approx. 45 mA max. 16 A resistive or 8 A inductive load of 230 V AC or 30 V DC surge resistance 250 A @ 10 ms potential-free or voltage switching / COM/NO/NC

Input monitoring

(at use of external resistors)

Input line length

System limitations

Input / loop terminals max. 2,5 mm² (AWG 26-14)

Relay contact / power supply terminals max. 6 mm2 (AWG 30-10)

Ambient temperature

Storage temperature

Air humidity

Type of protection

Color

Weight

Dimensions

Declaration of Performance

FCT mode: 1 k / 6 k8 / 10 k

TAL mode: 1 k / 10 k (NO) or 6 k8 / 10 k (NC)

500 m max. 127 pieces per loop

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP65 gray, similar to RAL 7035 approx. 250 g

W: 150 mm H: 116 mm D: 67 mm

DoP-20792130701

Accessories

804870 Alarm and monitoring module for IQ8TAM

10

11

12

13

14

8

9

6

7

2

3

4

5

127

Transponders / Input & Output Modules esserbus

808606 esserbus transponder IQ8FCT XS

1

Features

Module for controlling and monitoring fire protection devices

Compatible with FlexES Control and IQ8Control

Power supply via the field bus esserbus

Integrated loop isolator

Programmable run-time monitoring (fire dampers)

Space-saving installation due to compact design

Installation on hat rail 35 mm

Optional housing for surface mounting

Approval: VdS G 209138

The IQ8FCT XS can be used to control and monitor external fire protection devices like fire dampers or as a technical alarm module (TAL) to monitor an external contact and control external load.

The transponder is connected on the esserbus® /esserbus®-PLus loop of fire control system

FlexES Control and IQ8Control.

FCT functionality

In this function a fire control device e.g. fire damper will be connected to the relay output of the

IQ8FCT XS and controlled according to the programming with configured runtime. Via the input the end positions of this external device are monitored. If the external device is leaving the set position e.g. at a power loss or is stuck a failure is recognized and indicated at the IQ8FCT XS and the fire control panel.

TAL functionality

Here an external contact can be connected and monitored via the input of the IQ8FCT XS. In case of an activation of this contact, the address and programmed additional text of the corresponding technical alarm module IQ8FCT XS will be displayed.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Relay contact

Input monitoring

Input line length

System limitations

Input / loop terminals

Ambient temperature

Storage temperature

Air humidity

Type of protection

Color

Weight

Dimensions

Declaration of Performance

14 ... 42 V DC approx. 45 mA max. 1 A / 30 V DC ot AC potential-free / COM / NO / NC

FCT mode: 1 k / 6 k8 / 10 k

TAL mode: 1 k / 10 k (NO)

500 m max. 127 pieces per loop max. 2,5 mm² (AWG 26-14)

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP30

IP50 (w. housing M200SMB/SMB6-V0) gray, similar to RAL 7035 approx. 90 g approx. 250 g (w. housing M200SMB) approx. 790 g (w. housing SMB6-V0)

W: 90 mm H: 93 mm D: 93 mm

W: 130 mm H: 143 mm D: 49 mm (w. h. M200SMB)

W: 245 mm H: 180 mm D: 100 mm (w. h. SMB6-V0)

DoP-20792130701

Accessories

804870 Alarm and monitoring module for IQ8TAM

M200SMB Surface mounting housing for one module

SMB6-V0 Surface mounting housing for 6 modules

128 www.hls-austria.com

Transponders / Input & Output Modules

1

808610.10

Features

Only one loop address is needed per transponder

Max. 100 transponders per FACP

Max. 32 transponders per loop

Max. 32 transponders per detector zone

esserbus esserbus transponder 12 relays (8 bit)

Approval: VdS, CNBOP, BOSEC

The esserbus transponder works as a loop device on the multi-functional primary line. With the 12 relays module, it is possible to expand the number of exits per control unit. Depending on the control unit, it can be integrated or used with fire detectors in mixed operation. The esserbus transponder can be optionally extended by adding the additional isolator board Part No. 788612. esserbus transponder voltage supply: via the multi-functional primary line. The esserbus transponder can be wired with an external switching voltage of 12V DC or 24V DC for the K1 to K12 relays. The external voltage supply of the transponder can be programmed to be monitored in the customer data in the operating mode. In the “floating” operating mode, no external switching voltage of the relays is necessary. 11 relays are freely programmable. The maximum line length from the transponder to the external device is up to 1000 m.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Current consumption @ 12 V DC

Contact load relay

Ambient temperature

Storage temperature

Air humidity

Type of protection

Weight

Dimensions

Declaration of Performance

10 ... 28 V DC approx. 250 μA approx. 3 mA

30 V DC / 1 A (max. 3 A each transponder)

-10 °C ... 50 °C

-25 °C ... 75 °C

< 95 % (non-condensing)

IP 40 (with housing) approx. 110 g

W: 150 mm H: 82 mm D: 20 mm

DoP-20611130701

External power supply is only optional – the transponder is fully operational with loop powering only.

Accessories

788612 Loop isolator PCB

788600 Surface mounting housing gray, similar to RAL 7035

788650.10 Surface mounting housing white, similar to RAL 9003

788601 Flush mounting housing gray, similar to RAL 7035

788651.10 Flush mounting housing white, similar to RAL 9003

10

11

12

13

14

8

9

6

7

2

3

4

5

129

Transponders / Input & Output Modules

1

808611.10

Features

Only one loop address is needed per transponder

Max. 100 transponders per FACP

Max. 32 transponders per loop

Max. 32 transponders per detector zone

esserbus esserbus transponder 32 LED

Approval: VdS, CNBOP, BOSEC

The esserbus transponder works as a loop device on the multi-functional primary line. 32 optocoupler outputs for direct LED control (e.g. indicator) are found on this esserbus transponder module. There is one terminal screw per output on the switching mechanism. The module can be extended by adding the additional isolator board Part No. 788612. esserbus transponder voltage supply: via the multi-functional primary line. The esserbus transponder requires an external power supply.

The external voltage supply of the transponder can be programmed to be monitored in operating mode. The maximum line length from the transponder to the external device is up to 100 m.

Technical Data

Operating voltage

Quiescent current @ 12 V DC

Ambient temperature

Storage temperature

Air humidity

Type of protection

Weight

Dimensions

Declaration of Performance

10 ... 15 V DC approx. 3 mA

-10 °C ... 50 °C

-25 °C ... 75 °C

< 95 % (non-condensing)

IP 40 (with housing) approx. 95 g

W: 150 mm H: 82 mm D: 20 mm

DoP-20611130701

Accessories

788612 Loop isolator PCB

788600 Surface mounting housing gray, similar to RAL 7035

788650.10 Surface mounting housing white, similar to RAL 9003

788601 Flush mounting housing gray, similar to RAL 7035

788651.10 Flush mounting housing white, similar to RAL 9003

1

808615 esserbus communication transponder for ECP 8010

With this esserbus transponder the extinguishing relay output 8010 can be integrated on the bus of panel 8000, IQ8Control and FlexES, thus enabling several extinguishing zones to be networked with each other. On each bus, a maximum of eight 8010 extinguishing relay outputs can be operated and a maximum of 16 communication transponders for each FACP8000 C/M, IQ8Control and

FlexES. All indicators and controls can be activated from the fire alarm panel. The communication transponder occupies one address on the esserbus. With integrated loop isolator on board.

Maximum 8 transponders per loop and max. 16 transponders per FACP.

Technical Data

Current consumption

Ambient temperature

Storage temperature

Air humidity

Type of protection

Weight

Dimensions max. 28 mA

-10 °C ... 50 °C

-25 °C ... 75 °C

< 95 % (non-condensing)

IP 40 (with housing) approx. 28 g

W: 72 mm H: 65 mm D: 20 mm

Mounting: in the housing of the 8010 extinguishing relay output

Including loop isolator PCB (Part No. 788612)

130 www.hls-austria.com

Transponders / Input & Output Modules esserbus

1

808619.10

esserbus FSA transponder for fire doors

Approval: VdS

Features

Only one loop address is needed per transponder

Usage of series 9200 intelligent detectors (such as OT, OTI, O²T detectors) as FSA detectors is possible

Connection of IQ8Quad O detectors (Part No.

802371), TD Detectors (Part No. 802271), OT detectors (Part No. 802373) and O²T detectors

(Part No. 802374) (DIBt-approved) as FSA detectors is possible

FSA detectors programmable as devices in the loop

Status indicator of door arrester system to the

FACP

Actuation of the locking device also via the automatic fire detectors in non-FSA operation

Stand-alone operation of the FSA transponders is possible

Usage of IQ8Quad O detectors (Part No.

803371), TD detectors (Part No. 803271) and

O²T detectors (Part No. 803374) in stand-alone operation of the FSA transponders to the standard detector group is possible

Max. 100 transponders per FACP

Max. 32 transponders per analog loop

Max. 127 detector zones per analog loop

Detector numbers per zone input of the transponder:

Max. 30 conventional detectors (without SOC)

Max. 10 conventional detectors (with SOC)

Max. 10 Manual call points

Max. 10 Technical Alarm Modules (TAM/TAL)

The transponder is suitable for usage for various applications: in stand-alone operation or on the esserbus. In esserbus operation, the Series 9200 automatic fire detectors and those of the

IQ8Quad family (see features for types) can be used as detectors in door arrester systems (FSA -

Fire, Failure and Shut-Off). In FSA transponder loop operation, the door arrester system status is indicated on the fire alarm control panel.

For stand-alone operation, detectors of the IQ8Quad family are supported without loop isolator

(see features for types).

For operation, the transponder requires an external supply voltage. It is possible to monitor this voltage.

Technical Data

Operating voltage

Quiescent current @ 12 V DC

Current consumption

Contact load relay

Ambient temperature

Storage temperature

Air humidity

Type of protection

Weight

Dimensions

Declaration of Performance

10 ... 28 V DC approx. 6 mA (from UB ext) max. 28 mA (from UB ext) max. 30 V DC/1 A or 48 V DC/0,5 A

-5 °C ... 50 °C

-25 °C ... 75 °C

< 95 % (non-condensing)

IP 40 (with housing) approx. 70 g

W: 72 mm H: 65 mm D: 20 mm (PC Board)

DoP-20614130701

Corresponding connection examples for FSA transponder operation in stand-alone operation or as a device in the fire detection System 8000 can be found in the chapter containing automatic door release systems.

Accessories

788612 Loop isolator PCB

788603.10 Module housing for C-mounting bar or top hat rail mounting

788600 Housing surface mount, gray

788650.10 Housing surface mount, white

788601 Housing flush mount, gray

788651.10 Housing flush mount, white

808625 EOL-Z

10

11

12

13

14

8

9

6

7

2

3

4

5

131

Transponders / Input & Output Modules

1

808630.10

Features

For connection of 3rd party detectors

Only one loop address is needed per transponder

Max. 100 transponders per FACP

Max. 31 transponders per loop

Max. 32 transponders per detector zone

1

808631.10

esserbus esserbus transponder RZT, 24 V

Approval: VdS

The refurbishment zone transponder is a stand-alone participant on the esserbus for the fire alarm system 8000 and IQ8Control FACP. Individual automatic fire detectors and manual call points

(conventional technology) from other manufacturers can be connected to the 4 zone inputs. The voltage of all 4 zones can be configured to 24 V via the internal DC/DC module. An additional reset module is not required to operate third-party detectors.

The two relay outputs are available for general control purposes.

Programmable with the programming software tools 8000 Version V2.40 or higher.

Technical Data

Operating voltage

Current consumption

Contact load relay

Ambient temperature

Storage temperature

Air humidity

Weight

Dimensions

Declaration of Performance

10.5 ... 15 V DC max. 1.250 mA max. 30 V DC/1 A or 48 V DC/0,5 A

-10 °C ... 50 °C

-25 °C ... 75 °C

< 95 % (non-condensing) approx. 150 g

W: 150 mm H: 82 mm D: 20 mm

DoP-20615130701

Whether or not a connection is possible must be individually checked in advance by the technical sales department.

Accessories

788612 Loop isolator PCB

788600 Housing surface mount, gray

788601 Housing flush mount, gray

788650.10 Housing surface mount, white

788651.10 Housing flush mount, white

788605 Mounting kit

esserbus transponder RZT, 12 V

Same as 808630.10, but rated voltage is 12 V DC, not configurable.

Technical Data

Operating voltage

Current consumption

Contact load relay

Ambient temperature

Storage temperature

Air humidity

Weight

Dimensions

Declaration of Performance

Accessories

788612 Loop isolator PCB

788600 Housing surface mount, gray

788601 Housing flush mount, gray

788650.10 Housing surface mount, white

788651.10 Housing flush mount, white

788605 Mounting kit

10.5 ... 13.8 V DC max. 1.250 mA max. 30 V DC/1 A or 48 V DC/0,5 A

-10 °C ... 50 °C

-25 °C ... 75 °C

< 95 % (non-condensing) approx. 150 g

W: 150 mm H: 82 mm D: 20 mm

DoP-20615130701

132 www.hls-austria.com

Transponders / Input & Output Modules esserbus

Accessories for esserbus Transponders

1

788612 Loop isolator for transponder

Loop isolator PCB to be mounted on esserbus transponders. To isolate short circuit failure and wire break on the loop.

Technical Data

Ambient temperature

Storage temperature

Air humidity

Type of protection

Weight

Dimensions

Declaration of Performance

-20 °C ... 50 °C

-20 °C ... 75 °C

< 95 % (non-condensing)

IP 50 (with housing) approx. 10 g

W: 32 mm H: 20 mm D: 10 mm

DoP-20611130701

1

808624 EOL-O terminating device

The EOL-O terminating device is mounted on the last control input device in the detector zone and is used to monitor alarm signaling devices.

Features

Used for monitoring of control outputs with conventional alarm signaling devices being connected

Additionally recognizes creeping interruptions and short-circuits

Loop monitoring in compliance with EN 54-13

1

808626 EOL-I terminating device

The EOL-I terminating device is mounted on the last device in the detector zone and is used to monitor detector zone inputs.

Features

Used for monitoring of detector zone inputs with standard fire detectors being connected

Additionally recognizes creeping interruptions and short-circuits

Loop monitoring in compliance with EN 54-13

1

804870 Alarm and monitoring module for IQ8FCT XS, IQ8FCT LP

An external, monitored contact can be connected to the terminals of the IQ8FCT XS or LP. In case of contact activation, the address and the programmed additional text of the corresponding

IQ8FCT XS or LP will be displayed.

The max. cable length to the connected module must not exceed 500 meters!

10

11

12

13

14

8

9

6

7

2

3

4

5

133

Transponders / Input & Output Modules esserbus

Technical Alarm Modules

1

804868 IQ8TAL with isolator, 1 contact IN/1 OUT

Approval: VdS

Features

One contact input and one floating relay output

Voltage supply via the field bus

Test and reset function

Higher IP55 protection with Part No. 704965

Programmable inverse monitoring functionality of the contact input (1k resistance latent/10k resistance fire)

Powered by the FACP

Total cable length of the external contact up to

500 m

Integrated loop isolator

Max. 127 transponder TAL electronic modules per analog loop

The technical alarm device IQ8TAL is a fully-fledged loop device of the IQ8Control fire detection system and facilitates the detection and forwarding of technical alarms.

The IQ8TAL is equipped with an integrated loop isolator, a contact input and a relay output. An external NO or NC may be connected to a single IQ8TAL. When an alarm is triggered the address and the programmed additional text of the IQ8TAL to which the contact is connected are displayed automatically. The integrated relay can be optionally configured as a normally-closed contact or as a normally-open contact. The IQ8TAL does not need a separate voltage supply.

In order to increase the IP protection class, the optional IP 55 protection kit (Part No. 704965) can be used.

The functionality of the IQ8TAL can be tested with the included key and the alarm status can be reset directly at the device.

Technical Data

Quiescent current @ 19 V DC

Contact load relay

Operation indicator

Alarm display

Connection terminal

Application temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

Declaration of Performance approx. 45 μA

30 V DC/AC/1 A green LED red LED max. 2.5 mm² (AWG 26-14)

-20 °C ... 70 °C

-30 °C ... 75 °C

< 95 % (non-condensing)

IP 43, IP 55 with cover 704965

PC/ASA plastic blue, similar to RAL 5015 approx. 110 g

W: 88 mm H: 88 mm D: 21 mm

W: 88 mm H: 88 mm D: 57 mm (with surface- mounted housing)

DoP-20792130701

Please note that for surface mounting, the mount housing (Part No. 704981) must be ordered separately.

Compatible with all IQ8Control systems with firmware V3.08 and tools 8000 V1.14 or superior.

2 x 10 k (terminating), 1 x 1 k (alarm), 1 x 6.8 k (inverse operation)

Accessories

704965 Protective kit for MCP and TAL, transparent

704981 Surface mount housing for small MCP, blue

704981 Surface mount housing for small MCP and TAL, blue, similar to RAL 5015

Blue, for small design electronic modules. Cable entry requires cable glands 704147, 704148.

134 www.hls-austria.com

Transponders / Input & Output Modules

1

704965 esserbus

Protective kit for MCP and TAL, transparent

Transparent, suitable for small MCPs. The cover serves as a protection to prevent inad vertent activation and to protect from high humidity.

Technical Data

Type of protection

Cover and two neoprene seals

IP55

10

11

12

13

14

8

9

6

7

2

3

4

5

135

Notes

136 www.hls-austria.com

Wireless Components

Wireless Modules

10

11

138-144

12

8

9

6

7

2

3

4

5

13

14

137

Wireless Components Wireless Modules

Features

Radiocommunication transmission features

Interference-proof transmission via dual band with frequency hopping @ 433 MHz and 868

MHz

Bi-directional data traffic

Permanent automatic interference monitoring of transmission path

In case of interferences, automatic modification of frequency band and radiocommunication channel

Band blocking detection

High transmission range (in the open air: max.

300 m)

Automatic interference detection due to low field strength levels

The following wireless modules are only compatible with IQ8Control panel. Communication between the RF devices is set up via a dual band transmission mode. The RF-technology applies frequency hopping to enable highest transmission security. In case of interference, the frequency band and the radiocommunication channels are automatically modified. If the entire band and the receiver are blocked due to high interference level, a fault signal is transmitted to the fire alarm panel. Thus, secure and reliable wireless transmission is provided.

The transmission range in open air is up to 300 m. Inside the building, the transmission range varies, depending on building structure, wall thickness or use of reinforced concrete.

IQ8Wireless radio technology facilitates the cable-free connection of IQ8Quad automatic fire detectors (with and without alarm signaling devices), manual call points and the IQ8Alarm alarm signaling device to the IQ8Control fire alarm system.

Already existing fire alarm systems can be expanded using the wireless technology or complete fire alarm systems can be realized for smaller objects with wireless components as well.

The allocation of the wireless components to a wireless transponder or wireless gateway takes place via the tools 8000 programming software.

The status of the batteries is checked automatically and their necessary replacement is displayed early on as a detector failure on the FACP and/or the wireless transponder*.

The optimal installation site as well as the maximum possible transmission distance can be conveniently and quickly transmitted via the tools 8000 integrated field strength measurement.

* during allocation of the wireless components via wireless transponder

Please take into account that the use of wireless components requires extra training, covering project planning and commissioning. For further information see our training brochure.

These devices were designed, produced and labeled for operation within the countries of the

European Union (EU) in accordance with the current EU standards and requirements. In case the device is installed outside of the EU, national guidelines and requirements must be taken into consideration.

For further information, please contact your local sales representative.

Using components like IQ8Alarm and IQ8Quad with integrated alarm devices the esserbus

PLus is needed.

max. 32 wireless detectors max. 10 control groups

12 V DC esserbus-PLus max.

10 wireless call points

Connection example

138 www.hls-austria.com

Wireless Components Wireless Modules

1

805593.10

IQ8Wireless detector base

Approval: VdS

With the IQ8Wireless base, the wireless component is located in the base onto which the respective fire detector is placed. The wireless base facilitates the connection of the IQ8Quad TM, TD, O,

O²T and OTG detectors via a wireless transmission line to the esserbus/esserbus-PLus and integrates them via wireless transponder or wireless gateway into the fire alarm system.

A maximum of 32 radio bases per wireless transponder and/or 10 per radio gateway can be allocated.

135 mm

45 mm

86 mm

Wireless base

Wireless base with Detector

Features

The wireless detector base suitable for

Fixed heat detector (Part No. 802171, 802177)

Rate-of-rise heat detector (Part No. 802271,

803271)

Optical smoke detector (Part No. 802371,

803371)

O²T multisensor fire detector (Part No. 802374,

803374)

OTG multisensor fire detector (Part No. 802473)

The wireless detector base features

Individual detector identification on the control panel

Regular functionality check for each detector

Alarm and operation display on the detector

Alarm and fault transmission in accordance with

EN 54-2

Easy detector or battery replacement with detector removal tool

Fault signal when the mounted wireless base and the inserted detector are removed

Permanent monitoring of battery voltage

Up to 2 years battery life depending on detector type and environmental conditions

Technical Data

Operating voltage

Current consumption

Battery operating time

Range inside

Range outside

Frequency band 1

Frequency band 2

Data transmission speed

Application temperature

Storage temperature

Air humidity

Type of protection

Material

Color

Weight

Specification

Dimensions

Declaration of Performance

4 x 3.6 V batteries approx. 50 µA approx. 3 years* max. 30 m max. 300 m

433 MHz with 16 channels

868 MHz with 7 channels

19.2 Kbit/s

-5 °C ... 55 °C

-20 °C ... 70 °C (w/o batteries)

15 °C ... 35 °C (with batteries)

< 95 % (non condensing)

IP 42

ABS-V0 white, similar to RAL 9010 approx. 315 g (incl. batteries)

EN 54-18:2005/-25:2008

Ø: 135 mm H: 49 mm (with detector H: 88 mm)

DoP-20622130701

The batteries to be used are components of the device approval according to EN 54 and are specified by the manufacturer. With the IQ8Wireless radio components, only the approved batteries with Part No. 805597 may be used. Use of batteries other than those specified by us automatically voids the product’s device approval (VdS-approval) and may not be used for example in Germany in fire alarm systems under legal building regulations.

*The battery operating time is dependent on the type of detector/device used, as well as the application temperature and additional surrounding conditions. It can be substantially restricted by increased current consumption of the wireless devices in the case of alarm, wireless interference or poor transmission, or even possibly through contact resistance at the contacts. Please note important instructions for usage of batteries in manual Part No.

798941.10 (available at the website).

4 x 3.6 V lithium batteries (Part No. 805597)

Accessories

805597 4 x 3.6 V lithium batteries

Room 1 Room 1 Room 1

8

9

6

7

2

3

4

5

10

11

12

13

14

1 2

Room 1 Room 1

Expansion via IQ8Wireless gateway with IQ8Wireless detector base

3

Room 1

139

Wireless Components Wireless Modules

1

805594.10

IQ8Wireless gateway for devices

Approval: VdS

135 mm

45 mm

Wireless base

Wireless base with detector

This wireless gateway is especially designed for convenient and time-saving expansion of an already existing IQ8Control/FlexES Control fire detection system. By removing a detector already installed on the loop and adding the wireless gateway to the standard IQ8 detector base, up to 10 additional fire detectors equipped with wireless detector bases or 10 addressable manual call points can be added to the existing system. Up to 10 components with alarm signaling functions –

IQ8Alarm alarm signaling devices and/or IQ8Quad fire alarms with integrated alarm signaling device – can be connected per wireless gateway via the universal wireless interface. And all this without any additional cabling. Depending on the surrounding conditions, the wireless transmission can reach up to 200m. The wireless gateway must fundamentally be operated with an IQ8Quad detector. It integrates the intelligent IQ8Wireless components into the esserbus or esserbus-PLus via the wireless base or wireless interface, thus making these components fully individually addressable loop devices.

Up to 9 wireless gateways can be operated on the loop. Each wireless gateway reduces the maximum number of esserbus devices by 12 pieces.

86 mm

Features

The wireless gateway can be mounted between detector base and IQ8Quad detector. No additional wiring required

Suitable for IQ8Quad detectors w/o alarm devices

The connection of an remote LED indicator for this detector is possible

Wireless communication with up to 10 users

Maximum 10 wireless bases

Maximum 10 wireless interfaces with IQ8MCP manual call points

Maximum 10 control groups for wireless interface with IQ8Quad/IQ8Alarm alarm signaling devices

All wireless devices are integrated as individually addressable on the esserbus / esserbus-

PLus

esserbus integration of all radiocommunication devices as individually addressable users

The radiocommunication devices can be allocated in up to 10 detector zones

Up to 9 wireless gateways per loop

Alarm and trouble transmission in accordance with EN 54-2

Easy detector or battery replacement via detector removal tool

Trouble signal when removing the gateway and the detector

Permanent monitoring of battery voltage

One gateway requires one loop address

The total number of loop devices of the loop will be reduced by only 12 devices for each connected IQ8Wireless Gateway

Max. 18 IQ8Wireless Gateways per FACP

IQ8Control C

Max. 45 IQ8Wireless Gateways per FACP

IQ8Control M and FACP FlexES Control

Accessories

805597 4 x 3.6 V lithium batteries

Technical Data

Operating voltage

Voltage supply

Current consumption

Battery operating time

Range inside

Range outside

Frequency band 1

Frequency band 2

Transmitter power

Sensitivity

Data transmission speed

Application temperature

Storage temperature

Air humidity

Type of protection

Material

Color

Weight

Specification

Dimensions

Declaration of Performance

8 ... 42 V DC (via loop)

4 x 3.6 V lithium battery

400 µA to max. 2,5 mA approx. 3 years* max. 20 m max. 200 m

433 MHz with 16 channels

868 MHz with 7 channels

10 mW

-100 dBm

19,2 Kbit/s

-5 °C ... 55 °C

-20 °C ... 70 °C (w/o batteries)

15 °C ... 35 °C (with batteries)

< 95 % (non-condensing)

IP 42

ABS white, similar to RAL 9010 approx. 265 g (incl. batteries)

EN 54-17:2005/-18:2005/-25:2008

Ø: 135 mm H: 49 mm (with detector H: 88 mm)

DoP-20620130701

The standard detector base version IQ8Quad 805590 is not included in the RF gateway package.

The batteries to be used are components of the device approval according to EN 54 and are specified by the manufacturer. With the IQ8Wireless radio components, only the approved batteries with part no. 805597 may be used. Use of batteries other than those specified by us automatically voids the product’s device approval (VdS-approval) and may not be used for example in Germany in fire alarm systems under legal building regulations.

*The battery operating time is dependent on the type of detector/device used, as well as the application temperature and additional surrounding conditions. It can be substantially restricted by increased current consumption of the wireless devices in the case of alarm, wireless interference or poor transmission, or even possibly through contact resistance at the contacts. Please note important instructions for usage of batteries in FB 798941.

4 x 3.6 V lithium batteries (Part No. 805597)

140 www.hls-austria.com

Wireless Components Wireless Modules

1

805595.10

IQ8Wireless transponder for devices, wall mount

Approval: VdS

136 mm

144 mm

280 mm

This wireless transponder is designed for wall mounting. The wireless transponder communicates with up to 32 other wireless devices. These can be wireless of various types from intelligent automatic fire detectors or wireless interfaces with manual call points and/or alarm signaling devices of the IQ8-family. Using the System IQ8Control/FlexES Control, the wireless transponder integrates the intelligent automatic detectors (with and without alarm signaling devices), manual call point and alarm generator IQ8Alarm in the esserbus / esserbus-PLus via the wireless base and/or wireless interface. The detector base allows esserbus integration of intelligent automatic detectors as bus devices with individual addressing via the transponder. Up to 10 transponders can be operated on one loop. The transponder can be linked with the loop as well as with a conventional detector zone or it can be operated as a stand-alone unit. Potential-free outputs for common fault and common fire are available. For system 8000 the transponder for RF devices can only be connected by using a potential-free relay to 4 IN/2 OUT or 1 IN transponder, because it is not compatible with panel

8000 and it cannot be used as a bus device.

The transponder needs an external supply voltage for operation.

200 mm

39 mm

Features

RF communication with up to 32 users

maximum 32 wireless bases

maximum 10 wireless interfaces with IQ8MCP manual call points

maximum 10 control groups for wireless interface with IQ8Quad/IQ8Alarm alarm signaling devices

esserbus integration of all RF. Devices as individually addressable users

The RF devices can be assigned in up to 32 detector zones

Alarm and fault transmission in accordance with

EN 54-2

Connection to esserbus of IQ8Control panel as bus device as well as to a conventional detector zones

Stand-alone operation

Potential-free outputs for common fault and common fire

Technical Data

Operating voltage

Quiescent current @ 12 V DC

Alarm current @ 12 V DC

Range inside

Range outside

Frequency band 1

Frequency band 2

Data transmission speed

Contact load relay

Application temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Specification

Dimensions

9 ... 30 V DC (via loop) approx. 17 mA approx. 18 mA max. 30 m max. 300 m

433 MHz with 16 channels

868 MHz with 7 channels

19,2 Kbit/s

30 V DC/1 A

-5 °C ... 55 °C

-10 °C ... 60 °C

< 95 % (non condensing)

IP 42

ASA + PC white, similar to RAL 9010 approx. 250 g

EN 54-17:2005/-18:2005/-25:2008

W: 200 mm H: 280 mm D: 39 mm (with detector H: 88 mm)

DoP-20621130701 Declaration of Performance

The external power supply of the IQ8Wireless transponder can come from the FACP or from an external power unit.

The voltage for the wireless transponder can be supplied by the FACP or an external power supply. An individual, separately protected supply line must be installed for the voltage supply. The external voltage supply is monitored by the wireless transponder. If the wireless transponder is installed as a device on the IQ8Control/FlexES Control, fire system, analog loop, a disturbance is transmitted to the fire detection control unit via the loop and is indicated there.

30 up to 300 m

Max. 10 control groups with alarm devices max. 32 wireless detectors

12 V DC esserbus-PLus max. 10 wireless call points

Max. 3 m

8

9

6

7

2

3

4

5

10

11

12

13

14

141

Wireless Components Wireless Modules

1

805601.10

IQ8Wireless universal interface w/o cover, red

Approval: VdS

The radio interface allows the IQ8MCP (small or large design) to be connected on the wireless esserbus-PLus.

The radio interface connects the intelligent IQ8MCP to the esserbus/powered loop via the IQ8Wireless transponder or the IQ8Wireless gateway. Thus, the devices are automatically converted into individually addressable loop devices.

Features

Radio interface suitable for:

IQ8MCP - electronic module, large design (Part

No. 804905/ 804906)

IQ8MCP – complete package, small design

(Part No. 804971)

IQ8MCP - electronic module, small design (Part

No. 804955), only with mounting frame (Part No.

704967)

IQ8Quad detectors (with and without alarm signaling devices)

IQ8Alarm alarm signaling device (Part No.

8073xx)

Radio interface features:

The IQ8 components are individually identified on the FACP

Regular functionality performance checks of IQ8 components

Fault signal when the IQ8 components are removed from the FACP

Operating mode display directly at the IQ8 manual call point and IQ8Quad detector

Alarm and fault message transmission in compliance with EN 54-2

Easy detector removal and battery replacement using multi-functional key

Remote operation of IQ8 components possible

(max. 3 meters) via 2-wire line

Constant battery status monitoring

Early battery replacement notification at the

FACP

Technical Data

Operating voltage

Current consumption

Battery operating time

Range inside

Range outside

Frequency band 1

Frequency band 2

Data transmission speed

Application temperature

Storage temperature

Air humidity

Type of protection

Material

Color

Weight

Specification

Dimensions

Declaration of Performance

4 x 3.6 V batteries approx. 30 μA approx. 3 years* max. 30 m max. 300 m

433 MHz with 16 channels

868 MHz with 7 channels

19,2 Kbit/s

-5 °C ... 55 °C

-20 °C ... 70 °C (w/o batteries)

15 °C ... 35 °C (with batteries)

< 95 % (non-condensing)

IP 42

PC/ASA plastic red, similar to RAL 3020 approx. 285 g (incl. batteries, without attachment)

EN 54-18:2005/-25:2008

W: 135 mm H: 135 mm D: 20 mm (without attachment)

DoP-20623130701

Only use small manual call points with mounting frame Part No. 704967.

The batteries to be used are components of the device approval according to EN 54 and are specified by the manufacturer. With the IQ8Wireless radio components, only the approved batteries with Part No. 805597 may be used. Use of batteries other than those specified by us automatically voids the product’s device approval (VdS-approval) and may not be used for example in Germany in fire alarm systems under legal building regulations.

*The battery operating time is dependent on the type of detector/device used, as well as the application temperature and additional surrounding conditions. It can be substantially restricted by increased current consumption of the wireless devices in the case of alarm, wireless interference or poor transmission, or even possibly through contact resistance at the contacts. Please note important instructions for usage of batteries in in manual Part No.

798941.10 (available at the website).

4 x 3.6 V lithium batteries (Part No. 805597)

Accessories

704967 Mounting frame for small MCP

805603 IQ8Wireless-mounting frames for IQ8Alarm

805601.10

805602.10

704967

Application example for large MCP

142 www.hls-austria.com

Wireless Components

1

805602.10

1

704967

IQ8Wireless universal interface w/o cover, white

Approval: VdS

As 805601.10, but white color.

Accessories

704967 Mounting frame for small MCP

805603 IQ8Wireless-mounting frames for IQ8Alarm

805604 IQ8Wireless-mounting frames for IQ8Quad

Wireless Modules

Mounting frame for small MCP, red and white

The mounting frame is useful for mounting MCPs on different international flush mount boxes.

Technical Data

Color

Dimensions red, similar to RAL 3020 white, similar to RAL 9010

W: 132 mm H: 132 mm D: 8 mm

2 x Fastening screws are included (red and white)

1

805603

or

Application example: Mounting frame with small MCP

IQ8Wireless mounting frames for IQ8Alarm, red and white

The mounting frame is used for the mounting of the IQ8Alarm alarm signaling devices onto the

IQ8Wireless interface Part No. 805601.10/805602.10.

Technical Data

Color

Weight

Dimensions

1 x mounting frame red

1 x mounting frame white red, similar to RAL 3020 white, similar to RAL 9010 approx. 64 g

W: 133 mm H: 133 mm D: 21 mm

8

9

6

7

2

3

4

5

10

11

12

13

14

= + +

IQWireless interface +

IQ8Alarm

Application example

IQWireless interface

805601.10 (red) or

805602.10 (white)

Mounting frames

805603

IQ8Alarm devices

8072xx or 8073xx

143

Wireless Components

1

805604

Wireless Modules

IQ8Wireless mounting frame for IQ8Quad detectors, white

The mounting frame is used for the mounting of the IQ8Quad fire detector with or without integrated alarm signaling device onto the IQ8Wireless interface 805602.10.

Technical Data

Color

Weight

Dimensions white, similar to RAL 9010 approx. 41 g

W: 133 mm H: 133 mm D: 21 mm

1

805605

= + + +

IQWireless interface +

IQ8Quad detector with integrated alarm device

IQWireless interface

805602.10

Application example

Mounting frame Standard detector base IQ8Quad detector

805604 805590 with integrated alarm device

80238x

IQ8Wireless cover for wireless interface, red and white

For applications in which the IQ8 components are not to be directly mounted (remote connection) on the IQ8Wireless interface Part No. 805601.10/805602.10, the wireless interface can be used with the filler panel.

Technical Data

Color

Weight

Dimensions

1 x Red cover plate

1 x White cover plate red, similar to RAL 3020 white, similar to RAL 9010 approx. 33 g

W: 133 mm H: 133 mm D: 8 mm

12 V DC esserbus-PLus max. loop length 3,5 km

12 V DC

Max. 10 wireless MCPs

Operation via wireless interface and

2-wire connection

(max. 3 meter)

Application example

144 www.hls-austria.com

Detectors for Special Applications

Flame and Heat Detectors

Air Duct Detectors

Linear Heat Detectors

Linear Smoke Detectors

Aspirating Smoke Detectors

10

11

146-153

154-156

157-163

164-171

172-188

12

13

14

8

9

6

7

2

3

4

5

145

Detectors for Special Applications Flame and Heat Detectors

Flame Detectors

1

782311

Features

Direct linking and voltage supply via standard detector group at the esserbus transponder

(Part No. 808623.10)

Base installation and alignment via mounting bracket (Part No. 783312)

High IP protection for indoor and outdoor usage

Operation and fault status displayed on the detector

Self-monitoring via internal sensors

Easy testing with magnet via integrated reed switch

UV flame detector UniVario

Approval: VdS

UV flame detector for the recognition of fast developing fires with flame formation. Operation, fault and fire statuses are displayed via LEDs on the detector. The supply voltage and the linking take place directly via the standard detector zone at the esserbus transponder (part no. 808623.10).

Resetting of the detector is also carried out directly via the same esserbus transponder.

Technical Data

Operating voltage

Quiescent current @ 9 V DC

Alarm current @ 9 V DC

Area to be monitored

Height to be monitored

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

Declaration of Performance

9 V DC approx. 500 μA typ. 15 mA max. 676 m² max. 45 m

-20 °C ... 80 °C

-40 °C ... 85 °C

< 95 % (non-condensing)

IP 67

Die cast aluminum red, similar to RAL 3000 approx. 945 g (incl. base and bracket)

W: 130 mm H: 140 mm D: 92 mm

DoP-20567130701

Detector base and mounting bracket are not supplied!

1

782315 Three-channel infrared flame detector UniVario

Approval: G 211041

UniVario three-channel IR flame detector for recognition of quickly developing fires with flame development. Optical windows of the IR sensors are fully monitored. The detector achieves a high level of resistance towards disturbance variables via three-channel infrared evaluation. Voltage supply and connection occur directly via the standard detector zone at the esserbus transponder

(Part No. 808623.10). The detector is also reset directly via the same esserbus transponder.

Features

Direct linking and voltage supply via standard detector group at the esserbus transponder

(Part No. 808623.10)

Base installation and alignment via mounting bracket (Part No. 783312)

3-channel infrared flame detector

High level of protection against disturbance variables thanks to optimized hardware and development of special algorithms

Maximum level of response sensitivity according to EN54-10, Class 1

Each optical channel has separate functional monitoring

Easy testing with magnet via integrated reed switch

Technical Data

Operating voltage

Quiescent current

Alarm current @ 9 V DC

Area to be monitored

Height to be monitored

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

Declaration of Performance

9 V DC approx. 3.5 mA typ. 21.8 mA max. 676 m² max. 45 m

-20 °C ... 80 °C

-40 °C ... 85 °C

0 ... 95 % (non-condensing)

IP 67

Die cast aluminum red, similar to RAL 3000 approx. 991 g (incl. base and bracket)

W: 130 mm H: 140 mm D: 92 mm

DoP-21055130701

Detector base and mounting bracket are not supplied!

146 www.hls-austria.com

Detectors for Special Applications Flame and Heat Detectors

Heat Detectors

1

782310 Heat detector UniVario

Approval: G 211039

For detection of open fires with fast development of heat. For usage in polluted industrial environments, interior and exterior areas. Voltage supply and connection occur directly via the standard detector zone at the esserbus transponder (Part No. 808623.10). The detector is also reset directly via the esserbus transponder.

Features

Direct linking and voltage supply via standard detector group at the esserbus transponder

(Part No. 808623.10)

Base installation and alignment via mounting bracket (Part No. 783312)

Microcontroller functional monitoring of heat sensors as well as software and hardware

Quick fire detection with high level of protection against false alarms

Comparison to typical false variables using intelligent evaluation algorithms

High level of electromagnetic compatibility

Various mounting possibilities

Oil-tight and high level IP 67 protection class as well as resistance to impact and vibration

Technical Data

Operating voltage

Quiescent current

Alarm current @ 9 V DC

Response temperature

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

Declaration of Performance

9 V DC approx. 0.15 mA typ. 15 mA

0 °C ... 90 °C

-20 °C ... 80 °C

-40 °C ... 85 °C

< 95 % (non-condensing)

IP 67

Die cast aluminum red, similar to RAL 3000 approx. 995 g (incl. base and bracket)

W: 130 mm H: 140 mm D: 85 mm

DoP-21053130701

Detector base and mounting bracket are not supplied!

1

782302 Heat detector UniVario, 200 mm

Approval: G 211040

Same as 782310, but with sensor rod length of 200 mm.

Technical Data

Quiescent current

Response temperature

Weight

Declaration of Performance approx. 0.25 mA

54 °C ... 400 °C approx. 1 kg

DoP-21054130701

Detector base and mounting bracket are not supplied!

8

9

6

7

2

3

4

5

12

13

10

11

14

147

Detectors for Special Applications

1

782306

782307

782308

Flame and Heat Detectors

Heat detector UniVario, 2 m

Same as 782310, but with sensor tube for installation in areas with poor accessibility such as shafts and canals.

Technical Data

Response temperature

Weight

54 °C ... 400 °C approx. 1.3 kg

Detector base and mounting bracket are not supplied!

Heat detector UniVario, 6 m

Same as 782306, but with sensor tube length of 6 m.

Technical Data

Weight approx. 1.4 kg

Detector base and mounting bracket are not supplied!

Heat detector UniVario, 9 m

Same as 782306, but with sensor tube length of 9 m.

Technical Data

Weight approx. 1.5 kg

Detector base and mounting bracket are not supplied!

Accessories

1

783312 Mounting bracket for UniVario flame detectors

Mounting bracket for alignment of the industrial flame detectors UniVario. Simple installation with base Part No. 783313.

1

783313

Features

Simple detector exchange via standard base principle

Fast installation via simple plug-in

Generous space for cabling for user-friendly installation

148 www.hls-austria.com

Standard base UniVario

Standard detector base for detectors of the UniVario product family.

Technical Data

Weight

Dimensions approx. 350 g

W: 130 mm H: 140 mm D: 36 mm

Detectors for Special Applications Flame and Heat Detectors

Intrinsically Safe Flame Detectors

1

FS24X-911-23-6

Features

Patented WideBand IR™ technology

Patented Electronic Frequency Analysis™

Visible sensor for optimum false alarm rejection

Selectable detection sensitivities

Field-of-View: 90° cone-of-vision

Dual microprocessors for reliable performance

Real-time clock for accurate time dating of events

FirePic™ — pre-fire event data storage

Event log with date and time stamp

RS-485 ModBus communication

Non-Isolated 4-20 mA Analog output (sink or source)

Alarm, Fault and Fire Verification relays

Automatic Optical Path and Electronic self-test

Patented Electronics Module for component protection with plug-in terminations for easy field installation

Two M25 conduit entries

Low power consumption

High RFI and EMI immunity

FM, ATEX, CE mark approvals

CU-TR approved

INMETRO approved

Meets SIL 2 requirements

Certified to EN54-10:2002

FM 3260 performance

Detects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions

Wide operating temperature range

Optimal false alarm rejection

Minimal maintenance for trouble-free operation

PC software and interface module (FSIM) for fault diagnostics real-time graphs (RTGs), and downloading of FirePics™ and event log

Suitable for a wide variety of applications

Easy electronics module replacement

Test lamps for manual testing

FS24X-911 3IR AL M25 FM/EN54

The FS24X multi-spectrum Triple IR (IR/IR/IR/Visible) Flame Detector, is one of the FSX family of advanced technology Electro-Optical fire and flame detectors. WideBand IR™, WideBand 4.3 micron IR™, and Visible detection technology with sophisticated software algorithms delivers the highest fire detection performance combined with optimal false alarm rejection. Unlike narrow-band detectors, the WideBand IR™ Infrared technology using high-speed solid-state Quantum sensors allows detection of most types of fires, hydrocarbon and non-hydrocarbon, in all weather conditions.

FS24X - Aluminium, M25, ATEX/IECEx, FM3260, EN54-10.

Advanced true triple IR Flame Detector for Hazardous Industrial areas.

Visual Indicators:

Green LED: Power; Red LED: Alarm; Yellow LED: Fault

Technical Data

Operating voltage

Field of view

Sensitivity

Response time

Power Consumption

Output Relays

Analog output

Loop resistance

Tempetarure range

Vibration

Wiring

Conduit entries

Dimensions

Housing

24 Vdc nominal (18-32 Vdc) - regulated

90° cone of vision, ± 45° from on axis

Very high (60m), high (45m), medium (30m) and low

(15m) - switch selectable

3-5 Seconds to 0.1 m2 (1 sq. ft.) n-Heptane fire at 30 m (100 ft.)

3-10 Seconds to 0.1 m2 (1 sq. ft.) n-Heptane fire at

60 m (200 ft.)

Operating: 56 mA @ 24 Vdc nominal

Alarm: 106 mA @ 24 Vdc nominal

Heater: 155 mA – additional

Note: Heater will turn on at -17ºC (0ºF)

Fire Alarm: SPDT (NO / NC) – De-energised/energized, latching/non-latching

Fault: SPST (NO) – De-energised, latching/ non-latching

Auxiliary: SPDT (NO / NC) – De-energised/energised, latching/non-latching

Contacts rating: 1 amp @ 24 Vdc

0 - 20 mA stepped - source or sink user selectable

50 - 400 Ohms

Operating: -60°C to +85°C (-76°F to +185°F)

Storage: -55ºC to +110ºC (-67ºF to +230ºF)

Meets or exceeds MilSpec 810C Method 514.2,

Curve AW12

2.5 mm2 (14 AWG) to 0.326 mm2 (22 AWG); shielded cable recommended

Two M25 conduit entries

W: 110,4 mm H: 124,2 mm D: 156,4 mm

Copper-free powder coated aluminum

Mounting bracket SM4 and cable glands FSX-25M25 have to be ordered separately.

Accessories

SM4 Stainless Steel Swivel mounting assembly for FS24X, and FS20X detectors

PSU-12 Universal charger for Test Lamps and Interface Kits. For 110-240 VAC with international plugs

TL-2055 IR Test Lamp for testing FSX detectors, explosion proof version. Incl universal charger

TL-1055 IR Test Lamp for testing FSX detectors, non-explosion proof version. Incl universal charger

SH-001 Sunshield (316 Stainless Steel)

FSX-25M25 Cable gland

FS24X-211-24-6

FS24X-911 3IR SS M25 FM/EN54

As FS24X-911-23-6 but 316 stainless steel.

8

9

6

7

2

3

4

5

12

13

10

11

14

149

Detectors for Special Applications Flame and Heat Detectors

1

FS20X-211-23-6

FS20X-211 IR/UV AL M25 FM/EN54

Based on the foundation of the highly successful and reliable SS4 detector, the FS20X detector represents a quantum leap in integrating Infrared and Ultraviolet sensing technologies. The FS20X is a multi-spectrum UV/Dual IR/VIS fire and flame detector with a proven UV solar-blind sensor.

The FS20X detector uses advanced algorithms for signal processing and fire and flame analysis to alarm to most fires in all industrial environmental conditions. If the detector’s UV signal is degraded due to heavy smoke or a contaminated lens, the FS20X’s patented WideBand IR™,

Near Band IR and Visible sensors will still alarm to fire, albeit at a reduced sensitivity and slower response time.

Features

Patented WideBand IR™ Infrared combined with Ultraviolet

Detection range greater than 60 m (200 feet) to

0.1 m2 (sq. ft.) heptane fire

Patented Electronic Frequency Analysis

Visible sensor for optimum false alarm rejection

Selectable detection sensitivities

Solar blind 90° field of view

Dual microprocessors for reliable performance

Real-time clock for accurate time dating of events

FirePic™ — Up to 6 pre-fire event data storage

Event log — Up to 200 events with date and time stamp

Built-in RS-485 ModBus communication

Built-in non-isolated 4-20 mA analog output (sink or source)

Alarm, Fault and Fire Verification relays

Automatic Optical Path and Electronic self-test

Patented Electronics Module for component protection with plug-in terminations for easy field installation

Two M25 conduit entries

Low power consumption

High RFI and EMI immunity

FM hazardous area approved

Ex d ATEX /IECEx approved

CU-TR approved

INMETRO approved

Meets SIL 2 requirements

Certified to EN54-10:2002

FM 3260 performance

Detects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions

Wide operating temperature range

Arc welding immunity

False alarm rejection

Minimal maintenance for trouble-free operation

PC software and interface module (FSIM) for fault diagnostics real-time graphs (RTGs), and downloading of FirePics™ and event log

Suitable for a wide variety of applications

The FS20X detector has a detection range in excess of 60 m (200 feet) (very high sensitivity setting) for the detection of a 0.1m2 (one square-foot) n-Heptane reference fire and has a field of view with a greater volumetric coverage than most UV/IR detectors.

FS20X - Aluminium, M25, ATEX/IECEx, FM3260, EN54-10.

Advanced UV/Dual IR/VIS Flame Detector for Hazardous Industrial areas.

Visual Indicators:

Green LED: Power; Red LED: Alarm; Yellow LED: Fault

Technical Data

Operating voltage

Field of view

Sensitivity

Response time

Power Consumption

Output Relays

Analog output

Loop resistance

Tempetarure range

Vibration

Wiring

Conduit entries

Dimensions

Housing

24 Vdc nominal (18-32 Vdc) - regulated

90° Horizontal Cone of vision, ± 45° from on axis

Very high (60m), high (45m), medium (30m) and low

(15m) - switch selectable

3-5 Seconds to 0.1 m2 (1 sq. ft.) n-Heptane fire at 30 m (100 ft.)

3-10 Seconds to 0.1 m2 (1 sq. ft.) n-Heptane fire at

60 m (200 ft.)

24 Vdc nominal (18-32 Vdc) - regulated

Fire Alarm: SPDT (NO / NC) – De-energised/ energized, latching/non-latching

Fault: SPST (NO) – De-energised, latching/ non-latching

Auxiliary: SPDT (NO / NC) – De-energised/energised, latching/non-latching

Contacts rating: 1 amp @ 24 Vdc

0 - 20 mA stepped - source or sink user selectable

50 - 400 Ohms

Operating: -40 to +85ºC (-40 to +185ºF)

Storage: -55 to +110ºC (-67 to +230ºF)

Meets or exceeds MilSpec 810C Method 514.2,

Curve AW12

2.5 mm2 (14 AWG) to 0.326 mm2 (22 AWG); shielded cable recommended

Two M25 conduit entries

W: 110,4 mm H: 124,2 mm D: 156,4 mm

Copper-free powder coated aluminum

Mounting bracket SM4 and cable glands FSX-25M25 have to be ordered separately.

Accessories

SM4 Stainless Steel Swivel mounting assembly for FS24X, and FS20X detectors

PSU-12 Universal charger for Test Lamps and Interface Kits. For 110-240 VAC with international plugs

TL-2055 IR Test Lamp for testing FSX detectors, explosion proof version. Incl universal charger

TL-1055 IR Test Lamp for testing FSX detectors, non-explosion proof version. Incl universal charger

SH-001 Sunshield (316 Stainless Steel)

FSX-25M25 Cable gland

FS20X-211-24-6

FS20X-211 IR/UV SS M25 FM/EN54

As FS20X-211-23-6 but 316 stainless steel.

150 www.hls-austria.com

Detectors for Special Applications Flame and Heat Detectors

FSL100 Series Flame Detectors

Approval: VdS, ATEX

Features

Indoor & outdoor use

Range of UV. UVIR, IR3

Zone 2/22 Ex proof

Hydrocarbon and non-hydrocarbon sources

Pressure compensation element, avoiding trapped moisture

Lightweight GRP housing with no grounding required

mA output

Relay output

Selection of relay set-up with DIP switches

Ease of installation

Swivel mounting with fine angle adjustment

Light Mounting Bracket

Entry Gland

Advanced Test Lamp available

The FSL100 Series of flame detectors from Honeywell delivers robust, fast and reliable detection of flaming fires in a wide range of applications. The range consists of UV, UVIR and IR3 flame detectors. All utilise sophisticated sensing and signal analysis to detect fires quickly while also rejecting false alarms. The FSL100 may be small and lightweight for easy installation but they are designed to work in tough environments both in and out of doors as well as potentially explosive atmospheres. With a large field of view they can detect a range of different types of fire including hydrocarbon and non hydrocarbon sources.

Available in UV, UVIR and 3IR to cover a wide range of industrial flame detection needs (please review applications sheet).

Visual Indicatiors:

Continuous green: normal operation

Continuous yellow: fault

Flashing yellow: Fault and guide to repeat self-test after a self-test failure

Continuous red: alarm

Technical Data

Range

Cone of vision

Operating voltage

Start up times

Alarm response time

Alarm output settings

Automatic & manual Self-Test

Operating current normal @ 24 V DC

Current in alarm @ 24 VDC

Housing

Dimensions

Weight

Temperature, operating

Typ of protection

Detector specification

EC-type examination certificate max. 35 m (IR3), 25 m (UV, UV/IR) alarming within 10 sec. to a 0.1 m2 n-heptane fire

90˚minimum horizontal and vertical

10 ... 28 V DC (12 ... 24 V DC nominal)

<10 sec

8 ... 30 sec

Selectable LEDs and relays latching/non-latching; factory setting: latching

Automatic Sensor Test (built in Self-Test) and manual

Self-Test approx. 25 mA approx. 75 mA

Glass Reinforced Polyester (GRP), Non-incendive.

UV resistant, Self-Extinguishing V–0 (UL-94)

H: 125 mm x W: 80 mm x D: 57 mm

465 g

- 40 ˚C ... +70 ˚C

IP65

EN54-10, FM3260

ATEX Zone2/22, FM Class 1, 2 & 3 Div2

Accessories

FS1000-SM21 FSL100 Swivel mount.

FSL100-TL FSL100 Test lamp, incl. universal charger and carrying case; non EX

8

9

6

7

2

3

4

5

12

13

10

11

14

FSL100-IR3

IR3 flame detector RED, ATEX FM EN54

FSL three-channel IR flame detector for recognition of quickly developing fires with flame development. The detector achieves a high level of resistance towards disturbance variables via threechannel infrared evaluation. It is suitable for most light industrial applications, storage areas and machinery. It is simple to install with Wide Field of View Solid 90 degree volume cone (Cone of

Vision - Field of View), Long Range; 30m @ 10 sec for 0,1 m² n-Heptane reference fire and both automatic and manually initiated self-test. IP65 housing is made of Glass Reinforced Polyester

(GRP). It is non-incendive, UV resistant, Self-Extinguishing V–0 (UL-94). Has proven exceptional resistance against acids, bases and solvents.

151

Detectors for Special Applications

FSL100-UV

FSL100-UVIR

Flame and Heat Detectors

UV flame detector RED, ATEX FM EN54

FSL UV flame flame detector for recognition of quickly developing fires with flame development.

The detector achieves a high level of resistance. It is designed for cold storages, fume hoods, heating rooms for chemicals, isolators and radio amplifier rooms. Detector is simple to install with wide field of view, solid 90 degree volume cone, Long Range; 25m @ 10 sec for 0,1 m² n-Heptane reference fire and both automatic and manually initiated self-test. IP65 housing is made of Glass

Reinforced Polyester (GRP), it is non-incendive, UV resistant, Self-Extinguishing V–0 (UL-94).

GRP housing of FSL has proven exceptional resistance against acids, bases and solvents.

flame detector RED, ATEX FM EN54

FSL-UV/IR flame detector for recognition of quickly developing fires with flame development. The detector achieves a high level of resistance. It is designed to be used in chemical storages, electric power transformers, fuel and plug-in hybrid stations, hydrogen storages and laboratories. Detector is simple to install with wide field of view, solid 90 degree volume cone, Long Range; 25m @ 10 sec for 0,1 m² n-Heptane reference fire and both automatic and manually initiated self-test. IP65 housing is made of Glass Reinforced Polyester (GRP), it is non-incendive, UV resistant, Self-Extinguishing V–0 (UL-94). GRP housing of FSL has proven exceptional resistance against acids, bases and solvents.

Accessories for Intrinsically Safe Detectors

DASA6-N Air shield assembly 6MM

FSX Air shield assembly protects the detector window from contaminants/dust.

SM4 Swivel mount

FSX - Universal Swivel Mount allows simple, robust and accurate mounting and sighting of FSX flame detectors. Supplied in Stainless Steel with angle markings to allow setting detector aiming.

FSX-A001 FSX kit with Interface, RS485,USB cables

Interface kit to enable access to detection logs and FirePics for post event analysis.

152 www.hls-austria.com

Detectors for Special Applications

TL-1055

Flame and Heat Detectors

Test lamp FS18X/FS20X/FS24X NON-EXP

FSX Safe Area Test Lamp for in-situ testing of flame detectors.

TL-2055

PSU-12

SH-001

FSL100-SM21

Test lamp FS18X/FS20X/FS24X EXP

FSX Hazardous Area Test Lamp for in-situ testing of flame detectors.

110/220VAC wallcharger test lamp

Charger for FSX test lamp

Sun shield SS SS2/SS4/FS24X

FSX Sunshield protects against direct sun.

FSL100 swivel mount

FSL100 Swivel mount enabling simple installation and aiming of the FSL100 range of flame detectors.

8

9

6

7

2

3

4

5

12

13

10

11

14

FSL100-TL FSL100 test lamp, charger & case; non EX

FSL100 Safe Area Test lamp to enable simple in-situ testing of the FSL100 range of flame detectors.

Accessories

FSL100-TLBT 12 VDC battery for FSL-TL test lamp

FSL100-TLCH Universal charger for FSL-TL test lamp

153

Detectors for Special Applications Air Duct Detectors

Air Duct Detectors

1

781443

Features

Single-tube air analysis system based on the

Venturi principle

Optimum utilization of air flow velocity through new Venturi tube design

Integrated maintenance opening in the front cover so that air duct smoke detector can be tested

Suitable for air duct widths from 0.6 to 2.8 m

Integrated air flow display

Venturi air duct module for IQ8Quad OTblue-LKM (802379)

Ventilation air duct module for usage of the OTblue-LKM Part No. 802379 air duct smoke detector in combination with Venturi tubes Part No. 781446, 781447 or 781448. The module is mounted on the outside of the air ducts.

The Venturi tube enters the duct and leads the air out of the duct through the detection chamber of the detector back to the duct and finally back into the duct. During operation, the detector and the alarm LED is visible so that an external parallel detector indicator is not required.

The housing need not be opened for maintenance purposes. Inspection of the detector be performed quickly and easily via a separate opening in the front of the housing.

Technical Data

Type of protection

Housing

Color

Weight

Dimensions

IP 54

ABS plastic gray approx. 800 g

W: 180 mm H: 235 mm D: 183 mm

Construction kit includes pipe gasket and cap. The following items are not included: IQ8Quad OTblue

LKM or detector base as well as the Venturi tube or filter cartridge.

Correct diameter calculation d h

:

Correct assembly site

Mounting on air ducts with mounting kit

Part No.781449

Turnaround of air flow

H

W d h

Air flow

5 d

Air outlet e.g.

D d h

= D

Air intake e.g.

Air flow

5 d

Application example with detector

5 d

154 www.hls-austria.com

Detectors for Special Applications

Accessories

1

802379

1

781444

Air Duct Detectors

OTblue-LKM multisensor fire detector IQ8Quad with isolator

Approval: VdS

Specially addressable IQ8Quad multisensor fire detector with integrated optical sensor and heat sensor and enhanced false alarm management. For application as air duct smoke detector in venturi air duct modules Part No. 781443. The optical measurement chamber is provided with a patented developed sensor technology using a high-sensitive blue LED (instead of the commonly used red LED in Optical smoke detectors), enabling the detection of open fires, smoldering fires and fires with high heat generation.

Especially for open fires, the classical ionization technology implemented in ionization detectors is replaced by the unique detection technology, unlike ionization detectors, this sensor works without a radioactive element which causes problems at the time of refuse disposal. The detector is capable of identifying the TF1 and TF6 test fires described in the EN 54-9:1982 specification. Well suited for sensitive environment, detection of invisible up to large aerosols.

The OTblue multisensor is an intelligent detector with time-related signal analysis, signal correlation of the sensor data, decentralized intelligence, automatic function self-test, CPU failure mode, automatic adaptation to environmental conditions, alarm and operating data memory, alarm indicator and soft-addressing.

The detector is provided with an integrated isolator and a parallel detector indicator can be connected.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Quiescent current @ FACP battery

Air speed

Application temperature

Storage temperature

Air humidity

Type of protection

Housing

Weight

Detector specification

Specification

Dimensions

Declaration of Performance

9 ... 42 V DC approx. 50 μA approx. 200 μA @ 27,5 V approx. 280 μA @ 42 V

1 ... 20 m/s

-20 °C ... 50 °C

-25 °C ... 75 °C

< 95 % (non condensing)

IP 43 (with base + option)

ABS plastic, white, similar RAL 9010 approx. 110 g

EN 54-7

EN 54-7/-17, CEA 4021

Ø: 117 mm H: 62 mm (incl. base)

DoP-20116130701

Only suitable for application in air duct construction set 781443.

Accessories

805590 Standard detector base for IQ8Quad

805591 Detector base with relay contact for IQ8Quad

Filter cartridge for air duct module 781443

For use in unclean environmental conditions.

8

9

6

7

2

3

4

5

12

13

10

11

14

155

Detectors for Special Applications

1

781446

1

781447

1

781448

1

781449

Air Duct Detectors

Venturi tube for IQ8Quad air duct construction set 781443, 0.6 m

Venturi tube 0.6 m for application with air duct construction set Part No. 781443 between 140 mm and 600 mm.

Technical Data

Material

Required borehole in the duct: 38 mm aluminum

Venturi tube for IQ8Quad air duct construction set 781443, 1.5 m

Venturi tube 1.5 m for application with air duct construction set Part No. 781443 between 600 mm and 1400 mm.

Technical Data

Material aluminum

Required boreholes in the duct: 38 mm below and 50 mm above.

Venturi tube, plastic gasket and rubber seal

Venturi tube for IQ8Quad air duct construction set 781443, 2.8 m

Venturi tube 2.8 m for application with air duct construction set Part No. 781443 between 1400 mm and 2700 mm.

Technical Data

Material aluminum

Required boreholes in the duct: 38 mm below and 50 mm above.

Venturi tube, plastic gasket and rubber seal

Mounting set for round and insulated air ducts

Mounting set for mounting the Part No. 781443 air duct construction set to round and / or insulated air ducts.

Venturi tube, plastic gasket and rubber seal

1

781445 Weather protection housing for air duct construction set 781443

Protects the air duct detector in difficult environmental conditions such as during use in outside areas.

The weather resistant housing can be subsequently fixed above the already mounted and installed air duct module Part No. 781443.

Technical Data

Type of protection

Material

Weight

Dimensions

IP 65 galvanized steel approx. 1.8 kg

Ø: 282 mm H: 280 mm

Opened condition

156 www.hls-austria.com

Detectors for Special Applications Linear Heat Detectors

1

Honeywell DTS Detector

Features

Multicolor LCD display

LED indicators: Alarm, Measurement, Fault, Operation

Temperature measurement and monitoring via fiberoptic sensor cable (Part No. 970150.IN or 970153.IN)

1, 2 or 4 measurement channels per evaluation unit

Loop or open line sensor cable topology

Up to 256 independent alarm zones per channel

Up to 10 km sensor cable for each channel

Laser power below 20 mW

10 seconds measurement cycles

Spatial resolution 0.5 m

Relay interface, optionally Modbus IP/RTU

Approval: VdS, UL, ATEX, LPCB

DTS (Distributed Temperature Sensing) System is capable of detecting fires and accurately locate spots of the fire. The system allows to precisely measure, locate and signalize already small differences of temperature changes by measuring and highlighting temperature of a specific spot vs. environment. Fire resistant (PH category) sensing cable is capable to take signals also during a fire, even when temperatures are up to 750°C (max. two hours). That allows to monitor the progress of fire and supervise fire rescue action accordingly.

The system can work as a standalone system or be easily integrated into existing management platforms (e.g. SCADA systems) by either communicating directly over Ethernet (TCP/IP) using

SCPI (standard commands for programmable instruments) or Modbus (IP or RTU).

Technical Data

Operating voltage

Power consumption

Operating temperature

Storage temperature

Air humidity

Type of protection

Weight

Dimensions

10 ... 30 V DC approx. 17 W @ 20 °C ambient temperature

-10 °C ... 60 °C

-40 °C ... 80 °C

< 95 % (non condensing)

IP30 approx. 9 kg

W: 448 mm H: 88 mm D: 364 mm 2 HU, 19"

970120.IN

970121.IN

970123.IN

970124.IN

970125.IN

970134.IN

Line heat detector Honeywell DTS - evaluation unit, distance range 1 km

Evaluation unit in a 19" rack mount housing.

Line heat detector Honeywell DTS - evaluation unit, distance range 2 km

As 970120.IN, but with a 2 km detection range.

Line heat detector Honeywell DTS - evaluation unit, distance range 4 km

As 970120.IN, but with a 4 km detection range.

Line heat detector Honeywell DTS - evaluation unit, distance range 6 km

As 970120.IN, but with a 6 km detection range.

Line heat detector Honeywell DTS - evaluation unit, distance range 10 km

As 970120.IN, but with a 10 km detection range.

Wall mount housing IP66 for Honeywell DTS detector

Approval: VdS, UL, ULC

Alternative IP66 wall mount housing with window for 97012X.IN rack housings.

Technical Data

Operating temperature

Storage temperature

Air humidity

Type of protection

Weight

Dimensions

Specification

4 x Pflitsch UNI Dicht cable glants

-10 °C ... 60 °C

-40 °C ... 80 °C

< 95 % (non condensing)

IP66 approx. 17 kg

W: 400 mm H: 500 mm D: 150 mm

EN54-22 (VdS) / UL 521 and ULC-S530

8

9

6

7

2

3

4

5

12

13

10

11

14

157

Detectors for Special Applications

Accessories

970129.IN

Linear Heat Detectors

Modbus TCP/IP interface for Honeywell DTS detector

Features

Modbus TCP slave

Full temperature trace

Trace index

Timestamp

Alarm status

Zone temperature values (max., min. and avg.)

970130.IN

Optional 2nd sensor channel for Honeywell DTS detector

The DTS evaluation unit is delivered as one channel device as a standard. By ordering 970130.IN the evaluation unit can be expanded by one additional channel. Two channel option enables to make a redundant loop.

970132.IN

970133.IN

Option for 4 sensor channel for Honeywell DTS detector

The DTS evaluation unit is delivered as one channel device as a standard. By ordering 970132.IN the evaluation unit can be expanded by three additional channel. Four channel option enables to make a full redundant loop.

Extention ATEX approval for Honeywell DTS detector

970166

970167

1

970135

Features

Modbus: RTU or IP

Entire temperature trace data

Independent alarm parameter per zone

Several status conditions such as fiber break

LAN: Ethernet 10/100 Mbps, RJ 45

Serial Interface: RS-232/422/485, DB9 male

DTS evaluation unit warranty extention, 3 years

Extended warranty extends the standard warranty period to 3 years. Warranty is applicable to one evaluation unit purchased together with the warranty. One warranty always covers one evaluation unit.

DTS evaluation unit warranty extention, 5 years

As 970166 but with a 5 year period.

DTS interface box

The DTS system can easily be integrated into SCADA systems, direct process control or external connections to fire control panels. The DTS interface box provides access via the Modbus protocol

RS 232, RS 422 and RS 485, as well as TCP/IP. Through a virtual host concept the data is available for each sensor (channel) as a Modbus unit. Meaning only one unit is required even for multiple channel operation. 10000 register holdings and 3000 register coil definitions can be assigned flexibly to each Modbus unit.

Technical Data

Operating voltage

Ambient temperature

Storage temperature

Air humidity

Weight

Dimensions

12 ... 48 V DC

-10 °C ... 60 °C

-20 °C ... 80 °C

5% to 95% (non condensing) approx. 200 g

W: 111 mm H: 77 mm D: 26 mm

158 www.hls-austria.com

Detectors for Special Applications

1

970138

970137

Linear Heat Detectors

Relay controller set for Honeywell DTS detector

If the application requires driving more than the embedded 20 relay outputs of Honeywell DTS detector, the relay controller set should be used. The set is capable of controlling up to 256 additional relay outputs per channel. Each relay output can be assigned flexibly to any defined alarm condition.

Technical Data

Operating voltage

Current consumption @ 24 V DC

Ambient temperature

Storage temperature

Air humidity

Weight

Dimensions

24 V DC approx. 350 mA (Controller)

0 °C ... 55 °C

-25 °C ... 85 °C

5% to 95% (non condensing) approx. 200 g

W: 55 mm H: 100 mm D: 70 mm (Controller)

1 x power supply

1 x pre-programmed relay controller

1 x digital output module

1 x end module

8 x relays with accessories for easy wiring

Relays extension set for Honeywell DTS detector

The Relays Extension Set adds another digital output module and 8 relays. For example, to offer

48 relays, 1 relay controller (Part No. 970138) and 5 Relays Extension Sets are necessary.

Technical Data

Operating voltage

Current consumption @ 24 V DC

Ambient temperature

Storage temperature

Air humidity

24 V DC approx. 25 mA (each IO card/relay)

0 °C ... 55 °C

-25 °C ... 85 °C

5% to 95% (non condensing)

1 x Digital output module

8 x Relays output with accessories for easy wiring

8

9

6

7

2

3

4

5

12

13

10

11

14

970139 High dense I/O interface set for Honeywell DTS detector

Cable connection set to connect evaluation unit relay outputs with fire alarm system.

1 x input cable, D-Sub 9, 230 cm

1 x 9 pin connnection box

2 x output cable, D-sub 44, 230 cm

2 x HD connection box

159

Detectors for Special Applications Linear Heat Detectors

Sensor Cables for Honeywell DTS Detector

1

970150.IN

FO sensor cable Safety FRNC

Fast responding sensor cable with tight buffered fiber. Compact dimensions, high flexibility and good bending behaviour. High tensile strength by Aramid yarns. The cable has a halogen-free and flame-retardant cable sheath.

Technical Data

Explosion protection

Material

Weight

ATEX 1 GD, 111/112

FRNC outer sheath, Armid fibers, thight-buffered fibers approx. 17 kg /km

Sensor cable will be delivered in requested length.

1

970153.IN

FO sensor cable Steel FRNC

Fast responding sensor cable armoured, with stainless steel loose tubes and outer sheath. High permissible tensile strength, high crush resistance. Longitudinally and laterally water tight. Excellent rodent protection. The cable has a halogen-free and flame retardant cable sheath.

Technical Data

Explosion protection

Material

Weight

ATEX 1 GD, 111/112

FRNC outer sheath, stainless steel wires, gel-free stainless steel loose tube, fibres with primary coating approx. 25 kg /km

Sensor cable will be delivered in requested length.

970151

970154

970151.IN

Features

4 LEDs: e.g. Power supply ON, fault signal

Integrated timer (1 to 10 min)

User friendly operation

Work with all fiber-optic cables

160 www.hls-austria.com

Sensor cable connectors for FO sensor cable 970150.IN

To reduce deployment cost and tim, we are optionally offering preassembled pig tails. This enable quick and easy onsite installation, with no need to organize a fusion splicer, splice box to get the sensing cable connected to the DTS detector. Pig tails are supplied with E2000 8° angled connectors. For safe transportation and installation the connectors and pig tails are covered by a flexible tube to ensure proper protection.

2x Connectors

Sensor cable connectors for FO sensor cable 970153.IN

As 970151, but for FO sensor cable steel FRNC (Part No. 970153.IN).

Sensor cable testing tool

The testing tool is used to verify fanctionalty of the sensor cable according to regional requirements.

Electronic boards control the heating sleeves to simulate a fire condition along the fiber-optic sensor cable. Protection devices are built-in for safe operation. Electrical connections are carried out by flexible cables, which are protected against mechanical damages by a resistant outer jacket.

The flexible cables have specific plugs for easy connection to the control circuit.

It is possible to use this tool without disassembling the installed mounting brackets (when the distance is at least 1m).

Technical Data

Power supply

Current consumption @ 24 V DC

Power consuption

Weight

Dimentions

230 V AC, 50 Hz max. 1.5 mA max. 350 W approx. 1 kg (control unit) approx. 2 x 1 kg (heating sleeves)

W: 350 mm H: 170 mm D: 440 mm (carrying case)

W: 160 mm H: 80 mm D: 240 mm (control unit)

Detectors for Special Applications

1

970154.IN

Linear Heat Detectors

E2000 APC 8° pigtail, 5 m

E2000 8° angled connectors with a 5 m pigtail offered to splice the sensing cables.

1

970161

1

970165.IN

E2000 APC adapter to connect two connectors 970154.IN

Used to connect two E2000 APC (Part No. 970154.IN) connectors.

Cutting tool for FO steel sensor cable 970153.IN

Recommended to cut the stainless steel tube, to properly remove the cable sheath and splicing the pigtail to the sensing fiber.

8

9

6

7

2

3

4

5

12

13

10

11

14

161

Detectors for Special Applications Linear Heat Detectors

Anchors for Honeywell DTS Detector

1

970140.IN

Features

For indoor and outdoor applications

Applicable for dynamic loads

UV-stabilized: 5 times better than PA6/PA66

Very low moisture absorption

High chemical resistance

Halogen free as per IEC-Norm 754-2

Steel anchor with plastic clamp for Honeywell DTS cables

Self-locking plastic cable clamps with zinc-plated steel anchor, ideal for installation on concrete walls and ceilings. With this mounting solution the sensor cable is fast and securely installed. This plastic cable clamp provides excellent resistance against corrosive and chemical atmospheres as well as an uncritical characteristic relating to fire (halogen free). The plastic cable clamp in combination with the metal free cable is especially suitable for use in rail tunnels where metal free components are often required.

To fix the clamps on the concrete a special concrete dowel type is used. The metal dowel is an anchor made of steel, which is placed into a drilled hole and anchored by deformation- controlled expansion. The anchor may be deployed in structures subject to dry internal conditions and also in structures subject to external atmospheric exposure in humid internal conditions or in other particular aggressive conditions e.g. immersion in seawater, chloride atmosphere or atmosphere with chemical pollution (e.g. in desulphurization plants or road tunnels where de-icing materials are used).

Technical Data

Ambient temperature

Type

Material

Color

Dimensions

-40 °C ... 110 °C

K6 x 30/15 polyamide (clamp), zinc plated steel (anchor) dark grey, similar to RAL 7001(clamp)

Ø: 6 mm L: 61 mm (metal anchor)

Please note: for mounting of the anchor, one ancher setting tool (Part No. 970144.IN) is necessary and is not included in delivery.

Other anchor lengths on request.

100 x plastic clamps

100 x anchor

1 x SDS drill

1

970142.IN

Stainless steel anchor with plastic clamp for Honeywell DTS cable

As 970140.IN but with stainless steel anchor.

Technical Data

Type

Material

Dimensions

100 x plastic clamps

100 x anchors

1 x SDS drill

K6 x 30/15 stainless steel (anchor)

Ø: 6 mm L: 61 mm (metal anchor)

1

970143.IN

Steel anchor with steel clamp for Honeywell DTS cables

As 970140.IN but with steel clamp, protected by rubber. The steel clamp complies with DIN 3016.

Technical Data

Material

100 x steel clamps

100 x anchors

1 x SDS drill steel zinc plated with rubber protection (clamp)

162 www.hls-austria.com

Detectors for Special Applications

970144.IN

Linear Heat Detectors

Anchor setting tool

To fix the metal anchor it is necessary to have one setting tool.

1 x setting tool

970146.IN

Features

2 cable inlets with sealing grommets

970147.IN

Micro splice-box IP20 for Honeywell DTS sensor cables

The splice box should only be used indoors and is suitable for cables with a diameter of max. 7.5 mm.

Technical Data

Type of protection

Material

Dimensions lP20 thermoplastic PC-ABS, non-halogen, flame retardant

W: 100 mm H: 160 mm D: 30 mm

1 x splice cassette with splice holder

Splice-box IP67 for Honeywell DTS sensor cables

For indoor or ourdoor use.

Technical Data

Type of protection

Material

Dimensions

1 x splice cassette with splice holder lP67

Aluminum, coated gray

W: 82 mm H: 128 mm D: 57 mm

8

9

6

7

2

3

4

5

12

13

10

11

14

Features

3 cable inlets with PG cable glands

970148 Double head cable ties, 500 pcs

163

Detectors for Special Applications Linear Smoke Detectors

Fireray

1

761315

Features

Compact housing

Range 5 m to 50 m

Robust construction

Complies with EN 54-12 standard

Monitoring and resetting is carried out via the esserbus transponder 808623 during loop operation

Fireray 50 RV with one prism

Approval: VdS

The detector consists of an integrated infrared transmitter and receiver. The signal is reflected by a prism and analysed by the receiving element. Signal reaching the threshold will trigger an alarm.

Integration on the loop and the resetting function is carried out via the esserbus transponder

808623.

Integration on conventional line requires use of a reset module. The detector requires a separate voltage supply of 24 V DC.

The Fireray is installed approx. 0.3 to 0.8 m underneath the ceiling and its reflector with the same ceiling distance opposite. There should be no reflecting obstacles in the transmission zone

(approx. 2 degrees).

Technical Data

Operating voltage

Quiescent current @ 24 V DC

Alarm current @24 V DC

Contact load

Range

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Detector specification

CE certificate

Dimensions

1 prism 761322

10.2 ... 30 V DC approx. 4 mA approx. 15 mA max. 30 V DC / 1 A

5 to 50 m

-20 °C ... 55 °C

-35 °C ... 60 °C

0% ... 93%, (non-condensing) lP50

ABS plastic, flame resistant gray, similar to RAL 7035 approx. 670 g

EN 54-12

0786-CPD-20045

W: 210 mm H: 117 mm D: 120 mm

esserbus transponder

Monitored area esserbus / esserbus PLus

24 V DC

1 retro mirror

Operating range: 5 up to 50 m

Application example

1

761316 Fireray 100 RV with four prisms

As 761315, but with four prisms and max. operating range of 100 m.

4 prisms 761323

164 www.hls-austria.com

Detectors for Special Applications Linear Smoke Detectors

1

1

761317

Features

Remote system controller

LASER assisted alignment

Automatic contamination compensation

Automatic IR beam path alignment

Electric remote detector head orientation adjustment

Fireray 5000, line smoke detector, incl. controller, 100 m

Approval: VdS, LPCB, UL

The Fireray 5000 combines an infrared transmitter and receiver in one detector head. The transmission signal is reflected by a prism and analyzed on smoke concentration by the receiving unit.

The trans mitting/receiving unit contains an electricactuator which always keeps the IR-ray in the optimal orientation.

Electric actuator in detector head allows for remote manual alignment via remote controller and its

LCD display, keypad and laser indicator. The automatic, self-alignment mechanism keeps detector head perfectly aligned with reflective prism regardless of vibrations or building construction movement.

Technical Data

Operating voltage

Quiescent current @ 24 V DC

Current consumption

Alarm current @ 24 V DC

Contact load

Range

Ambient temperature

Storage temperature

Type of protection

4 prisms 761322+761323

14 ... 28 V DC approx. 10 mA

8 mA ... 12 mA (niedrigen Strom-Modus typ 10) approx. 50 mA

100 mA / 30 V DC

8 ... 100 m

-20 °C ... 55 °C

-40 °C ... 85 °C

IP54

1

761317.50

Fireray 5000, line smoke detector, incl. controller, 50 m

As 761317, but with a 50 m detection range.

Technical Data

Range

1 prism 761322

8... 50 m

8

9

6

7

2

3

4

5

12

13

10

11

14

165

Detectors for Special Applications Linear Smoke Detectors

Reflectors and Accessories

1

761401.10

The individual reflectors and reflector sets can also be used with the Fireray products.

However, please observe the additional planning information in the relevant functional descriptions.

Reflector set for LRMX, for ranges of up to 80 m

Metal reflector set for different types of linear smoke detectors. Suitable for ranges of up to 80 m.

Technical Data

Range

Dimensions

5 ... 80 m

W: 370 mm H: 370 mm D: 7 mm

Suitable for all lines of supplied beam detectors.

Steel plate; 4 x reflector 761403

1

761402.10

1

761403

Reflector set for LRMX, for ranges of up to 100 m

Metal reflector set for range extension of LRMX up to 100 m.

Technical Data

Range

Dimensions

5 ... 100 m

W: 370 mm H: 370 mm D: 7 mm

Reflector sets also available on request with water-repellent reflectors Part No. 761413 (nano coating) or additional built-in heating.

Suitable for all lines of supplied beam detectors.

Steel plate; 9 x reflector 761403

Single reflector for LRMX

Replacement prism – single reflector for usage with the line smoke detector (Part No. 761400.10).

Technical Data

Range

Dimensions

5 ... 40 m

W: 100 mm H: 100 mm

Suitable for all lines of supplied beam detectors.

761317.H

Fireray 5000 detector head

Additional detector head for Fireray 5000 (761317).

166 www.hls-austria.com

Detectors for Special Applications

1

761317.50.H

Linear Smoke Detectors

Fireray 5000 detector head

Additional detector head for Fireray 5000 (761317.50).

1

761312

1

761314

1

761440

1

761441

Ceiling pendant mount for Fireray

Ceiling pendant mount for F2000, F5000, F50RV, F100RV and universal bracket 761314

Technical Data

Weight approx. 3.4 kg

Univ. bracket for F5000 or prism plate 761440/761441

Universal bracket for a F5000 detector head or prism plate 761440 or 761441

Technical Data

Weight approx. 300 g

Plate for 1 prism

Prism plate for 1 prism for use with bracket 761314

Technical Data

Weight approx. 150 g

Prism and bracket are not included!

Plate for 4 prism

Prism plate for 4 prisms for use with bracket 761314

Technical Data

Weight

Prisms and bracket are not included!

approx. 300 g

8

9

6

7

2

3

4

5

12

13

10

11

14

167

Detectors for Special Applications

1

761404.10

Linear Smoke Detectors

Ceiling holder for LRMX, for distances from 40 to 70 cm

For better mounting of the line smoke detector (Part No. 761400.10) on walls, girders, ceilings and beams. The ceiling bracket is made of aluminum and can be adjusted in length anywhere from 40 to 70 cm. A high-grade ball joint mounting bracket is located on the top side for easy wall/ceiling mounting. The ceiling bracket is suitable for attaching the mounting plate Part No. 761406.

Technical Data

Weight approx. 2.3 kg

Ceiling bracket incl. mounting material for the aluminum holder but does not include material for mounting of the holder on ceilings, walls or beams.

Features

For easy ceiling and wall mounting in compliance with DIN VDE 0833-2

Optimal alignment of detector and reflectors under difficult ambient conditions via ball joint mounting bracket

Extendable ceiling bracket for flexible adjustment of length for distances of 400 to 700 mm

Invisible cable routing inside the ceiling

Capacity 25 kg

Swivel hinge approx. 180°

Ball joint approx. 90° and holding fixture for prism reflector

RAL 9010 (pure white) surface

1

761405.10

Ceiling holder for LRMX, for distances from 70 to 150 cm

Same as 761404.10 but extendable for ceiling clearances from 70 to 150 cm.

Technical Data

Weight approx. 3.3 kg

1

761406 Mounting plate for ceiling bracket for detector/single reflector

Mounting plate made of aluminum for attaching the line smoke detector Part No. 761400.10 or the prism reflector Part No. 761403 on the ceiling bracket.

1

761407 Mounting spider for ceiling bracket

Mounting spider for the ceiling brackets (Part No. 761404.10 and 761405.10) for alternative attachment of the reflector sets (Part No. 761401.10 and 761402.10) on the ceiling bracket.

168 www.hls-austria.com

Detectors for Special Applications Linear Smoke Detectors

1

Open-area Smoke Imaging Detection (OSID)

The linear smoke detector OSID using dual wavelength detects only repeatable absolute smoke obscuration values, while rejecting the presence of dust particles or solid intruding objects. This is already provided using the simplest configuration – one imager and one emitter. One imager can work with up to seven emitters.

An optical imaging array in the OSID detector provides a wider viewing angle to locate and capture images. Consequently, the system is easier to install and align and can compensate for drift caused by natural shifts in building structures.

In addition, OSID requires only limited space (15 - 20 cm) in ist line of view. Therefore, the solution can be deployed safely between ceilings and supporting structures, moving cranes, etc.

Each component can be mounted directly to the surface or can be secured with the supplied mounting brackets.

Features

Patented dual wavelength, UV & IR, particle detection

High immunity to dust, fogging, steam, reflections and object intrusion

High tolerance to vibration and structural movement

Easy alignment with large adjustment and viewing angles

Simple installation, commissioning and maintenance

Simple DIP switch configuration

3D volumetric coverage

Maximum detection range up to 150 meters

3 levels of sensitivity possible (35%, 45%, 60 %)

Imager

10°

45°

90°

Field of View

Horizontal

38°

80°

Vertical

19°

48°

Detection Range

Standard Power

Min Max

30 m (98 ft) 150 m (492 ft)

Min

- -

High Power

Max

- -

15 m (49 ft) 60 m (197 ft) 30 m (98 ft) 120 m (393 ft)

6 m (20 ft) **34 m (111 ft) 12 m (39 ft) **68 m (223 ft)

Max.

Number of

Emitters

1

7

7

** Maximum Distances measured for the Center Field of View of the Imager. For more details on distances for the

Imager, see the OSID Product Guide.

Technical Data

Operating voltage

Range

Alignment angle

Ambient temperature

Air humidity

Type of protection

Weight

Detector specification

Dimensions

20 ... 30 V DC

< 150 m

-60° ... 60° (h), -15 ... 15° (v)

-10 °C ... 55 °C

10 ... 95 % (non-condensing)

IP44 (electronic)

IP66 (optical housing) approx. 651 g

EN 54-12

W: 198 mm H: 130 mm D: 96 mm

8

9

6

7

2

3

4

5

12

13

10

11

14

169

Detectors for Special Applications

761300

1

Features

Field of view coverage: horizontal 7°, vertical 4°

Linear Smoke Detectors

OSID Imager - 7° coverage

Approval: G211072

Imager for use with OSID emitter (Part No.: 761303 – 761305).

Image sensor / receiver for smoke detection for open spaces, evaluation. Two light sources (IR and

UV), optical filters, high-speed image capture and intelligent software algorithms to increase the noise immunity and safety from erroneous / false alarms, 1 light source can be connected, via sensors and DIP switch individually configurable.

Technical Data

Current consumption @ 24 V DC

Weight approx. 4 mA @ 1 imager, 7 mA @ 7 imagers approx. 651 g

Accessories

761310 OSID Installation Kit

761303 Emitter - Standard Power, battery version

761304 Emitter - Standard Power, wired at 24 V DC

761305 Emitter - High Power, wired at 24 V DC

1

761302 OSID Imager - 80° coverage

As 761300, but with field of view coverage: horizontal 80°, vertical 48°.

1

761303

Features

Built-in 5 year battery

OSID Emitter standard power, battery version

The emitter produces two light sources (UV / IR) which are evaluated by an OSID imager. The built-in battery lasts 5 years.

Technical Data

Weight

Dimensions

Accessories

761310 OSID Installation Kit

761300 Imager - 7° Coverage, 24 V DC

761302 Imager - 80° Coverage, 24 V DC approx. 563 g

W: 130 mm H: 198 mm D: 96 mm

1

761304 OSID Emitter standard power

As 761303, but wired.

Technical Data

Current consumption @ 24 V DC approx. 0,35 mA

1

761305 OSID Emitter, high power

As 761304, but with high powered emitter.

Technical Data

Current consumption @ 24 V DC approx. 0,8 mA

170 www.hls-austria.com

Detectors for Special Applications

1

761310

Linear Smoke Detectors

OSID installation kit

The installation kit is used for commisioning and maintenance of the OSID smoke detector.

1 x Laser alignment tool

1 x Test filter

1 x PC cable

1 x Cleaning cloth

1 x Manual

1

761330 IP66 housing for OSID standard light source (emitter)

Technical Data

Ambient temperature

Type of protection

Material

Dimensions

-25 °C ... 60 °C

IP66 , IK 07

ABS

W: 241 mm H: 194 mm D: 127 mm

1

761331 IP66 housing for OSID image sensor (imager)

Technical Data

Ambient temperature

Type of protection

Material

Dimensions

-25 °C ... 60 °C

IP66 , IK 07

ABS

W: 241 mm H: 194 mm D: 127 mm

8

9

6

7

2

3

4

5

12

13

10

11

14

171

Detectors for Special Applications Aspirating Smoke Detectors

Aspirating Smoke Detector - FAAST

8100E ASD FAAST XM

1

Approval: G 212002

The FAAST (Fire Alarm Aspiration Sensing Technology

®

) system is a aspirating smoke detector that draw air into a patented, high-sensitivity smoke-sensing chamber through a pipe network, it delivers highly accurate and discrete early warning fire detection. FAAST’s dual vision sensing technology uses a blue LED to detect a wide variety of fires with extremely low concentrations of smoke and an infrared laser to identify nuisances (like dust) which can cause false alarms.

Advanced algorithms interpret signals from both sources to meet one single focus. It includes 5 alarm levels, 10 pre-alarm particulate levels and a 10-level airflow pendulum which verifies that air is flowing effectively through the pipe network. The patented particle separator and field-replaceable filter remove contaminants from the pipe-system.

Features

Wide detection range between 0.00095 % and

20.5 % obs/m

Five alarm levels (Alert, Action 1 & 2, Fire 1 & 2)

Maximum Single Pipe Length 120 m

Maximum Branched Pipe Length 320 m

Maximum Air Inlet Holes 36 holes

Automatically adjusts to current environmental conditions to reduce nuisance alarms, Acclimate mode

Detector combines dual source chamber with a reliable and quick-responding blue LED technology and infra-red laser

Advanced detection algorithms reject common nuisance conditions

Ultrasonic and electronic sensing for pipe and chamber air flow measurement

Patented particle separator and field-replaceable filter

Integral Ethernet interface enables remote monitoring and e-mail status updates (up to 6 E- Mail addresses)

Particulate graph displays subtle environmental changes

Fault indictors provide a broad spectrum of events

Unique air flow pendulum graph verifies pipe network functionality

Event Log stores 18.000 events

PipelQ SW for programming pipe layout, system configuration and ongoing system monitoring

8 potential free relays output for connection at

FACP

Loop connection via esserbus-alarm transponder Part. No. 808623

Technical Data

Operating voltage

Quiescent current @ 24 V DC

Alarm current @ 24 V DC

Area to be monitored

Ambient temperature

Sampled Air Temperature

Air humidity

Type of protection

Housing

Color

Weight

Specification

Dimensions

Declaration of Performance

18 ... 30 V DC approx. 415 mA approx. 465 mA max. 2000 m²

-10 °C ... 55 °C

-20 °C ... 60 °C

10 ... 95 % (non-condensing)

IP 30

Plastic (ABS) black approx. 3.74 kg

EN 54-20

W: 330 mm H: 337 mm D: 127 mm

DOP 0786-CPD-21130

Please order separately the corresponding language package, see category accessory!

Accessories

F-A-LC-E Language package Estonian, Latvian, Lithuanian, Russian

F-A-LC-G Language package Polish, Czech, Slovak, Hungarian

F-A-LC-H Language package Slovenian, Croatian, Romanian, Hungarian

F-A3384-000 FAAST Replacement Air Filter

172 www.hls-austria.com

Detectors for Special Applications

F-A-LC-A

Aspirating Smoke Detectors

Language package German, French, Italian, Dutch

The language package for Aspirating FAAST XM includes the front foils in the languages German,

French, Italian and Dutch.

4 x front foils

F-A-LC-E Language package Estonian, Latvian, Lithuanian, Russian

The language package for Aspirating FAAST XM includes the front foils in the languages Estonian,

Latvian, Lithuanian and Russian.

4 x front foils

F-A-LC-G

Language package Polish, Czech, Slovakian, Hungarian

The language package for Aspirating FAAST XM includes the front foils in the languages Polish,

Czech, Slovakian and Hungarian.

4 x front foils

F-A-LC-H

Language package Slovenian, Croatian, Romanian, Hungarian

The language package for Aspirating FAAST XM includes the front foils in the languages Slovenian, Croatian, Romanian, Hungarian.

4 x front foils

1

F-A3384-000 Replacement air filter for FAAST XM

Replacement air filter for aspirating smoke detector FAAST XM.

1 x Air filter

8

9

6

7

2

3

4

5

12

13

10

11

14

173

Detectors for Special Applications Aspirating Smoke Detectors

801711 ASD FAAST LT EB, single channel

1

Approval: pending

The FAAST (Fire Alarm Aspiration Sensing Technology

®

) system is a aspirating smoke detector that draw air into a patented, high-sensitivity smoke-sensing chamber through a pipe network, it delivers highly accurate and discrete early warning fire detection. FAAST LT EB includes high sensitivity laser fire detection, ultrasonic flow sensors, and internal design features to protect vulnerable components from environmental and human threats. The device is fast to install and easy to commission thanks to PipeIQ LT pipe design and configuration software which is included as standard.

The FAAST LT esserbus will be connected direct on the esserbus. All devices are member from the esserbus loop and will be easy programmed with Commissioning Software tools8000.

A range of customisable settings are geared towards maximising device performance and meeting different application needs. To accommodate local installation standards or environments, flow and general fault delays can also be set.

Features

2 independant detection chambers w. individual laser smoke detector, fan, filter, sensor and monitor

1 channel system for connection of max. 2 pips per channel

Bild-in and preconfigured esserbus transponder

High sensitivity laser optics

9 sensitivity levels from 0.07 % to 6.5 % obs/m

Fault indictors provide a broad spectrum of events

PipelQ SW for programming pipe layout, system configuration and ongoing system monitoring

Simple LED overview with detailed fault status display

Unique air flow pendulum graph verifies pipe network functionality

10 adjastable fan levels

Advanced detection algorithms reject common nuisance conditions

Automatically adjusts to current environmental conditions to reduce nuisance alarms, Acclimate mode

Event Log stores up to 2.244 events

Ultrasonic and electronic sensing for pipe and chamber air flow measurement

USB interface

Easily replaceable and reusable filter

Technical Data

Operating voltage

Quiescent current @ 24 V DC

Alarm current @ 24 V DC

Operation sound level @ 24 V DC

Area to be monitored

Max. single pipe length

Max. total branched pipe length

Max. air inlet holes

Ambient temperature

Aspirated air temperature

Air humidity

Type of protection

Housing

Color

Weight

Specification

Dimensions

Declaration of Performance

24 language foils are included

Accessories

FL-IF-6 FAAST LT replacement integral filter

18.5 ... 31.5 V DC approx. 182 mA approx. 480 mA

26 dB (A) (fan level 1) max. 1600 m²

100 m

160 m

18

-10 °C ... 55 °C

-20 °C ... 60 °C

10 ... 95 % (non-condensing)

IP65

Plastic (ABS) black/gray approx. 4 kg

EN 54-20, Class A,B, C

W: 356 mm H: 403 mm D: 135 mm

DOP-ASP004

801722

Features

2 independant detection chambers w. individual laser smoke detector, fan, filter, sensor and monitor

2 channel system for connection of max. 2 pips per channel

ASD FAAST LT EB, dual channel

As 801722, but with 2 independant channels and one laser smoke detector per channel.

Technical Data

Quiescent current @ 24 V DC

Alarm current @ 24 V DC

Operation sound level @ 24 V DC

Declaration of Performance approx. 282 mA approx. 690 mA

28 dB (A) (fan level 1)

DOP-ASP005

FL-IF-6 Replacement integral filter for FAAST LT EB

Replacement integral filter for aspirating smoke detector FAAST LT EB.

6 x Integral filter

174 www.hls-austria.com

Detectors for Special Applications

1

801544.10

Aspirating Smoke Detectors

Air filter for aspirating smoke detectors

Air filter for usage in areas with interfering environmental influences e.g. dust.

Technical Data

Application temperature

Material

Color

Dimensions

Suitable for FAAST products

-30 °C ... 60 °C

ABS plastic gray, similar to RAL 7035

W: 122 mm H: 194 mm D: 96 mm

Filter cartridges (1 x 60 ppi, 1 x 45 ppi, 1 x 25 ppi)

1

801604 Replacement air filter pads for 801544.10

Replacement cartridge for air filters (801544.10), consisting of one fine, medium and coarse filter pad each.

Suitable for FAAST products

Filter cartridges (1 x 60 ppi, 1 x 45 ppi, 1 x 25 ppi)

1 Set

8

9

6

7

2

3

4

5

12

13

10

11

14

175

Detectors for Special Applications

1

VLP-400

Features

Wide sensitivity range

Laser based smoke detection

4 configurable alarm levels

High efficiency aspirator

Four inlet pipes

Airflow supervisor per sampling pipe

Clean air barrier optics protection

Easy to replace air filter

7 programmable relays

AutoLearn™

Event log – up to 18000 events

1

VLS-600

Aspirating Smoke Detectors

VESDA VLP

Approval: G 298024

The VESDA VLP detector has an alarm sensitivity range of 0.005%–20% obscuration/m

(0.0015%–6.25% obscuration/ft). The VLP is classed as a “Very Early Warning Smoke Detector”, which means that it detects fire at the earliest possible stage and reliably measures very low to extremely high concentrations of smoke.

The detection chamber uses a stable Class 1 laser light source and carefully positioned sensors to achieve the optimum response to a vast range of smoke types. The status of the detector, and all alarm, service and fault events, are transmitted to displays and external systems via VESDAnet.

Technical Data

Operating voltage

Quiescent current @ 24 V DC

Alarm current @ 24 V DC

Area to be monitored

Contact load relay

Alarm sensitivity

Cable termination

Max. single pipe length

Max. total branched pipe length

Ambient temperature

Aspirated air temperature

Air humidity

Type of protection

Weight

Specification

Dimensions

Filter included in detector

Accessories

VSP-005 VESDA Filter for VLP, VLS, VLF, VLC

18 ... 30 V DC max. 340 mA max. 390 mA max. 2000 m²

2 A @ 30 V DC NO/NC contacts

0.005%–20% obs/m (0.0015%–6.25% obs/ft)

0.2–2.5 sq mm

100 m

200 m

0 °C ... 38 °C

-20 °C ... 60 °C

10 ... 95 % (non-condensing)

IP30 approx. 4 kg

EN 54-20, Class A, B, C

W: 350 mm H: 225 mm D: 125 mm

VESDA VLS

As VLP-400 (VESDA VLP) , but also includes a valve mechanism in the inlet manifold and software to control the airflow from the four sectors (pipes). This configuration enables a single VESDA zone to be divided into four separate sectors, for example, distinguishing between separate voids within a room.

Technical Data

Quiescent current @ 24 V DC

Alarm current @ 24 V DC

Alarm sensitivity max. 280 mA max. 300 mA

0.005%–20% obs/m (0.0015%–6% obs/ft)

Features

4 configurable alarm levels

Four inlet pipes

7 or 12 programmable relay options

176 www.hls-austria.com

Detectors for Special Applications Aspirating Smoke Detectors

1

VLC-500RO

Features

Absolute smoke detection

Wide sensitivity range

Single pipe inlet

Five status LEDs

Clean air barrier optics protection

Three alarm levels

Three programmable relays

Air flow monitoring

Simple mounting design

AutoLearn™

Event log – up to 12000 events

VESDA VLC

Approval: G 298024

The VESDA VLC detector has been specifically designed to provide all the benefits of aspirating smoke detection, including very early warning, in single environment small areas and where space is a premium.

The VLC combines the well-proven VESDA VLP detection technology with a modified aspirator design, and incorporates them into a compact enclosure with a simplified display.

The detector interfaces via relays only.

Technical Data

Operating voltage

Quiescent current @ 24 V DC

Alarm current @ 24 V DC

Area to be monitored

Contact load relay

Alarm sensitivity

Cable termination

Max. single pipe length

Ambient temperature

Aspirated air temperature

Air humidity

Type of protection

Weight

Specification

Dimensions

18 ... 30 V DC approx. 225 mA approx. 245 mA max. 800 m²

2 A @ 30 V DC NO/NC contacts

0.005%–20% obs/m (0.0015%–6.25% obs/ft)

0.2–2.5 sq mm

80 m

0 °C ... 38 °C

-20 °C ... 60 °C

10 ... 95 % (non-condensing)

IP30 approx. 1,9 kg

EN 54-20, Class A, B, C

W: 225 mm H: 225 mm D: 85 mm

Filter included in detector

Accessories

VSP-005 VESDA Filter for VLP, VLS, VLF, VLC

1

VLF-250

Features

Out-of-the-Box installation and commissioning

Ultrasonic airflow sensing

Laser-based absolute smoke detection

Programmable alarm thresholds

Clean air barrier optics protecti

AutoLearn™ Flow

AutoLearn™ Smoke

Event log – up to 18000 events

VLF-500

VESDA VLF-250

Approval: G 205060

The VESDA VLF-250 detector is a very early warning smoke detector designed to protect small, business-critical environments of up to 250 m2.

The VLF can be installed and commissioned out-of-the-box without the need for a special interface or software programming tools. The patent-pending Ultrasonic Flow Sensing used in the VLF provides a direct reading of the sampling pipe fl ow rate. The system is immune to air temperature and pressure changes and is unaffected by contamination. The VLF is the first air sampling smoke detector to use ultrasonic flow sensing.

Technical Data

Operating voltage

Quiescent current @ 24 V DC

Alarm current @ 24 V DC

Area to be monitored

Contact load relay

Cable termination

Max. single pipe length

Ambient temperature

Aspirated air temperature

Air humidity

Type of protection

Weight

Specification

Dimensions

18 ... 30 V DC approx. 220 mA approx. 295 mA max. 250 m²

2 A @ 30 V DC NO/NC contacts

0.2–2.5 sq mm

25 m

0 °C ... 38 °C

-20 °C ... 60 °C

5 ... 95 % (non-condensing)

IP30 approx. 2 kg

EN 54-20, Class A, B, C

W: 256 mm H: 183 mm D: 92 mm

Filter included in detector

Accessories

VSP-005 VESDA Filter for VLP, VLS, VLF, VLC

VESDA VLF-500

As VLF-250 but for areas up to 500 m2.

Technical Data

Quiescent current @ 24 V DC

Alarm current @ 24 V DC approx. 410 mA approx. 490 mA

8

9

6

7

2

3

4

5

12

13

10

11

14

177

Detectors for Special Applications Aspirating Smoke Detectors

1

VLI-880

Features

Suitable for Class 1 Division 2 applications

- Groups A,B,C & D

Up to 4 inlet pipes

Five high intensity status LEDs for greater visibility

Robust absolute smoke detection

Intelligent Filter (patent pending)

Lint Trap to capture fibrous particulates

Secondary filter

Clean air barrier for optics protection

AutoLearn™ Smoke and Flow

Clean Air Zero™

Air-path monitoring

Five relays (Fire, Fault and 3 configurable)

Ultrasonic flow sensing

VESDA VLI Relay only

Approval: G 212155

The VESDA VLI is an early warning aspirating smoke detection (ASD) system, designed to protect industrial applications and harsh environments of up to 2000 m2.

The VLI detector combines a fail-safe intelligent filter (patent pending) with an advanced clean-air barrier for optics protection allowing the use of absolute detection and a long detection chamber life without the need for re-calibration.

The intelligent filter:

• reduces the level of pollution in the air sample before it enters the detection chamber, which dramatically extends the operational life of the detector in harsh and polluted environments.

• is fully monitored, providing consistent sensitivity over the entire operational life of the detector.

Technical Data

Operating voltage

Quiescent current @ 24 V DC

Alarm current @ 24 V DC

Area to be monitored

Contact load relay

Cable termination

Alarm sensitivity

Max. single pipe length

Max. total branched pipe length

Ambient temperature

Aspirated air temperature

Air humidity

Type of protection

Weight

Specification

Dimensions

Filter included in detector

18 ... 30 V DC approx. 415 mA approx. 440 mA max. 2000 m²

2 A @ 30 V DC NO/NC contacts

0.2–2.5 sq mm

0.005%–20% obs/m (0.0015%–6.25% obs/ft)

120 m

360 m

0 °C ... 38 °C

-20 °C ... 60 °C

10 ... 95 % (non-condensing)

IP66 approx. 6 kg

EN 54-20, Class A, B, C

W: 426.5 mm H: 316.5 mm D: 180 mm

VLI-885

VESDA VLI with VesdaNet

As VLI-880 but with VesdaNet implemented.

178 www.hls-austria.com

Detectors for Special Applications Aspirating Smoke Detectors

1

VEU-A00 VESDA VEU with LEDs

Approval: G 214010

The VEU series of aspirating smoke detectors are the premium detector of the VESDA-E range.

An Ultra-wide sensitivity range; 15 times greater than VESDA VLP, and provision for more sampling holes provide an increased coverage in high airflow applications by at least 40%. Considerably longer linear pipe runs and extended branched pipe network configurations cater perfectly to applications with higher ceilings providing an increased coverage by up to 80% whilst allowing convenient detector mounting for ease of service and maintenance. A range of revolutionary new features provide unsurpassed detection performance, flexibility, field programmability, connectivity and reduced total cost of ownership.

Features

Multi stage filtration and optical protection with clean air barriers

Four alarm levels and an ultra wide sensitivity range

Secondary monitoring and maintenance via WiFi

USB for PC configuration, and firmware upgrade using a memory stick

Remote monitoring with iVESDA

Fully backward compatible with VLP and

VESDAnet

AutoLearn™ smoke and flow

Extensive event log - 20 000 events

Flair Detection Technology

Flair is the revolutionary new detection chamber that forms the core of VESDA-E VEU, providing better detection, fewer nuisance alarms, higher stability, increased longevity and particle characterisation. Direct imaging of the sampled particles using a CMOS imager combined with multiple photo-diodes provides vastly more data that can be used to derive actionable information about the observed particles using analytics.

Technical Data

Operating voltage

Quiescent current @ 24 V DC

Alarm current @ 24 V DC

Area to be monitored

Contact load relay

Cable termination

Alarm sensitivity

Max. single pipe length

Max. total branched pipe length

Number of holes (A/B/C)

Ambient temperature

Aspirated air temperature

Air humidity

Type of protection

Weight

Specification

Dimensions

18 ... 30 V DC max. 613 mA max. 646 mA max. 6 500 m²

2 A @ 30 V DC NO/NC contacts

0.2–2.5 sq mm

0.001%–20% obs/m (0.0003%–6.25% obs/ft)

160 m

800 m

80/80/100

0 °C ... 38 °C

-20 °C ... 60 °C

10 ... 95 % (non-condensing)

IP40 approx. 4,83 kg

EN 54-20, Class A, B, C

W: 350 mm H: 225 mm D: 135 mm

Filter included in detector

Accessories

VSP-962 VESDA Filter for VEU, VEP

1

VEU-A10 VESDA VEU with Display

As VEU-A00 but with a 3,5" display.

Technical Data

Quiescent current @ 24 V DC

Alarm current @ 24 V DC

Weight approx. 658 mA approx. 692 mA approx. 4,9 kg

8

9

6

7

2

3

4

5

12

13

10

11

14

179

Detectors for Special Applications Aspirating Smoke Detectors

1

VEP-A00-P VESDA VEP 4 pipe with LEDs

Approval: G 214010

The VESDA-E VEP series of smoke detectors bring the latest and most advanced detection technology to provide very early warning and the best nuisance alarm rejection to a wide range of applications. Built on the Flair detection technology and years of application experience, VEP detectors achieve consistent performance over their lifetime via absolute calibration. In addition, the VEP delivers a range of revolutionary features that provide user value.

Features

Multi stage filtration and optical protection with clean air barriers

Four alarm levels and an ultra wide sensitivity range

Secondary monitoring and maintenance via WiFi

USB for PC configuration, and firmware upgrade using a memory stick

Remote monitoring with iVESDA

Fully backward compatible with VLP and

VESDAnet

AutoLearn™ smoke and flow

Extensive event log - 20 000 events

Flair Detection Technology

Flair is the revolutionary new detection chamber that forms the core of VESDA-E VEP, providing better detection, fewer nuisance alarms, higher stability, increased longevity and particle characterisation. Direct imaging of the sampled particles using a CMOS imager combined with multiple photo-diodes allow vastly more data that can be used to derive actionable information about the observed particles using analytics.

Technical Data

Operating voltage

Quiescent current @ 24 V DC

Alarm current @ 24 V DC

Area to be monitored

Contact load relay

Cable termination

Alarm sensitivity

Max. single pipe length

Max. total branched pipe length

Number of holes (A/B/C)

Ambient temperature

Aspirated air temperature

Air humidity

Type of protection

Weight

Specification

Dimensions

18 ... 30 V DC max. 367 mA max. 400 mA max. 2 000 m²

2 A @ 30 V DC NO/NC contacts

0.2–2.5 sq mm

0.005%–20% obs/m (0.00016%–6.25% obs/ft)

110 m

560 m

40/80/100

0 °C ... 38 °C

-20 °C ... 60 °C

10 ... 95 % (non-condensing)

IP40 approx. 4 kg

EN 54-20, Class A, B, C

W: 350 mm H: 225 mm D: 135 mm

VEP-A10-P

Filter included in detector

Accessories

VSP-962 VESDA Filter for VEU, VEP

VESDA VEP 4 pipe with display

As VEP-A00 but with a 3,5" display.

Technical Data

Quiescent current @ 24 V DC

Alarm current @ 24 V DC

Weight max. 417 mA max. 483 mA approx. 4,1 kg

VEP-A00-1P VESDA VEP 1 pipe with LEDs

As VEP-A00 but with one pipe.

Technical Data

Max. single pipe length

Max. total branched pipe length

Number of holes (A/B/C)

100 m

130 m

30/40/45

180 www.hls-austria.com

Detectors for Special Applications

1

761517

Aspirating Smoke Detectors

VESDAnet™ connection box

This connection box enables external devices to be connected to the VESDANet™. For example, a handheld programmer or a PC can be connected in conjunction with the PC interface to program the system.

1

761506

VSP-962

VSP-005

1

761509

VESDA 300 PC interface

Used as an alternative to the programming unit. All components on the VESDAnet™ can be programmed via the interface.

Technical Data

Current consumption

Dimensions

70 mA

W: 190 mm H: 100 mm D: 40 mm

The two required connectors are included.

VESDA filter for VEU, VEP

Replacement air filter for VESDA VEU and VEP detectors.

1 piece

VESDA filter for VLP, VLS, VLF, VLC

Replacement air filter for VESDA VLP, VLS, VLF and VLC detectors.

1 piece

Air filter for VESDA aspirating systems

External filter for VESDA aspirating system for extremely polluted environments.

Technical Data

Color

Dimensions gray, similar to RAL 7035

W: 206 mm H: 59 mm D: 33 mm

8

9

6

7

2

3

4

5

12

13

10

11

14

1

761514 Replacement filter for 761509

Replacement filter cartridge for air filter Item No. 761509. 1 set consisting of 4 filter cartridges.

181

Detectors for Special Applications

Accessories

1

950101

1

761520.10

Aspirating Smoke Detectors

Pipe (PVC), diameter 25 mm

Length = 25 m (each 5 m)

Technical Data

Ambient temperature

5 pcs

-10 °C ... 60 °C

Pipe (ABS), diameter 25 mm

Length = 30 m (each 3 m)

Technical Data

Ambient temperature

10 pcs

-40 °C ... 70 °C

1

950119 90° bend (PVC) for 25 mm pipe

Technical Data

Ambient temperature

10 pcs

-10 °C ... 60 °C

1

761521.10

1

950104

90° bend (ABS) for 25 mm pipe

As 950119 but ABS material.

Technical Data

Ambient temperature -40 °C ... 70 °C

90° angle (PVC) for 25 mm pipe

Technical Data

Ambient temperature

10 pcs

-10 °C ... 60 °C

1

761522.10

90° angle (ABS) for 25 mm pipe

As 950104 but ABS material.

Technical Data

Ambient temperature -40 °C ... 70 °C

182 www.hls-austria.com

Detectors for Special Applications

1

950107

Aspirating Smoke Detectors

45° angle (PVC) for 25 mm pipe

Technical Data

Ambient temperature

10 Pcs.

-10 °C ... 60 °C

1

761523.10

1

950110

1

761524.10

1

950116

45° angle (ABS) for 25 mm pipe

As 950107 but ABS material.

Technical Data

Ambient temperature -40 °C ... 70 °C

T-Piece (PVC) for 25 mm pipe

Technical Data

Ambient temperature

10 pcs

-10 °C ... 60 °C

T-Piece (ABS) for 25 mm pipe

As 950110 but ABS material.

Technical Data

Ambient temperature -40 °C ... 70 °C

Sleeve (PVC) for 25 mm pipe

Technical Data

Ambient temperature

10 Pcs.

-10 °C ... 60 °C

8

9

6

7

2

3

4

5

12

13

10

11

14

1

761525.10

Sleeve (ABS) for 25 mm pipe

As 950116 but ABS material.

Technical Data

Ambient temperature -40 °C ... 70 °C

183

Detectors for Special Applications

1

950113

Aspirating Smoke Detectors

End cap (PVC) for 25 mm pipe

Technical Data

Ambient temperature

10 pcs

-10 °C ... 60 °C

1

761526.10

1

761549

End cap (ABS) for 25 mm pipe

As 950113 but ABS material.

Technical Data

Ambient temperature -40 °C ... 70 °C

Ceiling lead-through adapter (ABS)

Ceiling lead-through adapter (ABS) for suction hose set (Part No. 761542.10).

Almost invisible integration into false ceilings

1

761542.10

Suctions hose set for 25 mm pipe

For flexible installation in object surveillance or suspended ceilings.

All components are pre-mounted, but not glued; to enable cut and adaptation on-site.

Technical Data

Dimensions L: 3000 mm

1 x T piece (761524), 3 m corrugated polyester hose, (761543), 1 x ceiling lead-through adapter with threaded joint

T-piece

False ceiling

Suspended ceiling

Application example: monitoring of room

Polyester hose

Aspirator sampling assembly

Pipe

184 www.hls-austria.com

Detectors for Special Applications Aspirating Smoke Detectors

1

801602

1

801607

3-way ball valve (PVC)

For manual disconnection of aspirating smoke detectors from connected piping system during the blow cleaning process with compressed air.

Technical Data

Ambient temperature

Material

Dimensions

0 °C ... 50 °C

ABS

L: 131 mm includes three transition screw joints for connection to a 25 mm piping system

3-way ball valve (ABS)

As 801602 but ABS material.

1

801606

Features

Plastic housing with manual outlet valve

Plug connectors for attaching to a piping system

Condensate trap for aspirating smoke detectors

Condensate trap with sintered metal filter for separation and absorption of condensed liquids, used for protecting aspirating smoke detectors including threaded cable connection and mounting bracket.

Technical Data

Ambient temperature

Material

Color

Weight

Dimensions

0 °C ... 80 °C

ABS light gray approx. 620 g

W: 68 mm H: 680 mm D: 36 mm

Air filter

Inlet

Condensate separator

Outlet Aspirating smoke detector

8

9

6

7

2

3

4

5

12

13

10

11

14

Outlet

Application example

185

1

761537.10

1

761546.10

Detectors for Special Applications

1

761535

Aspirating Smoke Detectors

Adhesive, 0.5 kg can with brush-in-cap

Adhesive for connecting ABS and PVC pipes.

1

761536 PVC detergent, 1l

Detergent for cleaning ABS and PVC pipes and fittings before gluing.

Mounting clip for 25 mm pipe

100 pcs

Pipe cutter for PVC and ABS pipes

Technical Data

Material ABS

Tool for clean, fast pipe cuts. For thin-walled pipes also, Ø ≤ 63 mm Ø ≤ 2".

186 www.hls-austria.com

801561

801562

801563

801564

Detectors for Special Applications

1

Reducing Film Sheets

Aspirating Smoke Detectors

Only 10 mm drill necessary

No annoying whistling

Defined diameter, easilyreadable on site

Finely graduated for optimal flow balance

10 pcs

801551

801552

801553

801554

801555

801556

801557

801558

801559

Aspiration reducing film sheet, 2.0 mm

Aspiration reducing film sheet, 2.5 mm

Aspiration reducing film sheet, 3.0 mm

Aspiration reducing film sheet, 3.2 mm

Aspiration reducing film sheet, 3.4 mm

Aspiration reducing film sheet, 3.6 mm

Aspiration reducing film sheet, 3.8 mm

Aspiration reducing film sheet, 4.0 mm

Aspiration reducing film sheet, 4.2 mm

8

9

6

7

2

3

4

5

12

13

10

11

14

801560 Aspiration reducing film sheet, 4.4 mm

Aspiration reducing film sheet, 4.6 mm

Aspiration reducing film sheet, 5.0 mm

Aspiration reducing film sheet, 5.2 mm

Aspiration reducing film sheet, 5.6 mm

187

Detectors for Special Applications

801565

Aspirating Smoke Detectors

Aspiration reducing film sheet, 6.0 mm

801566

801567

Aspiration reducing film sheet, 6.8 mm

Aspiration reducing film sheet, 7.0 mm

188 www.hls-austria.com

Alarm Devices

Conventional ENscape

Intelligent Addressable IQ8Alarm

Intrinsically Safe

Remote Indicators

10

11

190-196

197-206

207

208

12

13

14

8

9

6

7

2

3

4

5

189

Alarm Devices Conventional ENscape

1

CWSO-RR-S1

77 mm

100 mm

102 mm

Features

EN 54-3 compliant

Suitable for 12 V and 24 V DC service voltage

Synchronous sound trigger

Volume adjustable to 2 levels at the device

Acoustic alarm signaling device, red

Approval: G 215015

The acoustic alarm signaling device is EN 54-3 compliant, in red housing, and offers a selection of

32 signal tones including the DIN tone and other country-specific tones. All tones comply with EN

54-3. Configuration takes place via a 6-pin DIP switch. Up to two different signal tones may be activated. Signaling device with flat base, suitable for wall and ceiling mounting.

Technical Data

Operating voltage

Current consumption @ 12 V DC

Current consumption @ 24 V DC

Sound level @ 12 V DC

Sound level @ 24 V DC

Connection terminal

Ambient temperature

Air humidity

Type of protection

Material

Color

Weight

Specification

Dimensions

9 ... 29 V DC approx. 14.9 mA (@ DIN tone) approx. 33.4 mA (@ DIN tone)

96.2 dB(A) (@ DIN tone)

102.1 dB(A) (@ DIN tone)

0.5 ... 2.5 mm

2

-25 °C ... 70 °C

< 96 % (non-condensing)

IP21C, IP65 with CWR and accessories

PC/ABS, UL94-V0 red, similar to RAL 3020 approx. 190 g

EN 54-3 acoustic signaling device

Ø: 100 mm H: 77 mm

Ø: 100 mm H: 102 mm (incl. IP base)

Not suitable for use outdoors or in damp areas. Please use therefore the optional bases and accessories (Part No. CWR, PS188, PS189). Use of the deep IP socket reduces the dB output by an average of 4 dB. Replacement for Part No. 766225.

Accessories

CWR Base deep IP65, red

PS188 Base deep, O-Ring

PS189 Base deep, seal

1

CWSO-WW-S1 Acoustic alarm signaling device, white

Approval: G 215015

As CWSO-RR-S1, but white color.

Technical Data

Color

Accessories

CWW Base deep IP 65, white white, similar to RAL 9003

190 www.hls-austria.com

Alarm Devices Conventional ENscape

1

CWST-RR-S5

72 mm

100 mm

97 mm

Features

EN 54-23 compliant

C & W category

Synchronous flash trigger

Up to 6.2 m room width for wall mounting

Up to 9.4 m room diameter for ceiling mounting

Optical alarm signaling device EN 54-23 cat. W+C, red flash, red housing

Optical signaling device compliant with EN 54-23 for wall and ceiling mounting with red lamp color and flat base. The signaling device is suitable for square signal ranges W-2.4-6.2 and cylindrical signal ranges C-3-9.4 / C-6-8.2.

To help define your conventional Visual Alarm Devices (VADs) requirements in line with the EN54-

23 standard, we have developed an easy to use online guide. Simply enter the room dimensions and ambient light conditions and the guide will help your device selection: http://www.kac.co.uk/EN54-device-chooser.htm

Technical Data

Operating voltage

Current consumption @ 24 V DC

Frequency of flash

Flash color

Connection terminal

Ambient temperature

Air humidity

Type of protection

Material

Category wall

Mounting height wall

Room width

Category ceiling

Mounting height ceiling

Room diameter

Color

Weight

Specification

Dimensions

12 ... 29 V DC approx. 37 mA (@ DIN tone) approx. 0.5 Hz red

0.5 ... 2.5 mm

2

-25 °C ... 70 °C

< 96 % (non-condensing)

IP21C, IP65 with CWR and accessories

PC/ABS, UL94-V0

PC, UL94-V0 (Lens)

W-2,4-6,2

2.4 m

6.2 m

C-3-9,4 / C-6-8,2

3 m / 6 m

9,4 m / 8,2 m base red, similar to RAL 3020 cap: transparent approx. 164 g

EN 54-23 optical signaling device

Ø: 100 mm H: 72 mm

Ø: 100 mm H: 97 mm (incl. IP base)

Not suitable for use outdoors or in damp areas. Please use therefore the optional bases and accessories (Part No. CWR, PS188, PS189). Replacement for Part No. 766420, 766422,

766410.

Accessories

CWR Base deep IP65, red

PS188 Base deep, O-Ring

PS189 Base deep, seal

1

CWST-RW-S5 Optical alarm signaling device, EN 54-23 cat. W+C, white flash, red housing

As CWST-RR-S5, but with a white flash.

1

CWST-WR-S5

Optical alarm signaling device EN 54-23 cat. W+C, red flash, white housing

As CWST-RR-S5, but in a white housing.

Technical Data

Color base white, similar to RAL 9003 cap: transparent

Accessories

CWW Base deep IP65, white

PS188 Base deep, O-Ring

PS189 Base deep, seal

8

9

6

7

2

3

4

5

12

13

10

11

14

1

CWST-WW-S5 Optical alarm signaling device, EN 54-23 cat. W+C, white flash

As CWST-WR-S5, but with a white flash.

191

1

1

Alarm Devices

CWSS-RR-S5

98 mm

100 mm

122 mm

Features

EN 54-3 and 54-23 compliant

Synchronous sound and flash trigger

Volume adjustable to 2 levels at the device

C & W category

Signal range up to 6.0 m room width for wall mounting

Signal range up to 8.9 m room diameter for ceiling mounting

CWSS-RW-S5

CWSS-WR-S5

Conventional ENscape

Combined acoustic/optical alarm device EN 54-23 cat. W+C, red flash, red housing

Combined acoustic and optical alarm signaling device is EN 54-3 & EN 54-23 compliant, in red housing, and offers a selection of 32 signal tones including the DIN tone and other country-specific tones. All tones comply with EN 54-3. Tone configuration takes place via a 6-pin DIP switch. Up to two different signal tones may be activated. The optical signaling device with red signal lamp is suitable in accordance with EN 54-23 for square signal ranges W-2.4-6.0 and cylindrical signal ranges C-3-8.9 / C-6-8.2. Signaling device with flat base, suitable for wall and ceiling mounting.

To help define your conventional Visual Alarm Devices (VADs) requirements in line with the EN54-

23 standard, we have developed an easy to use online guide. Simply enter the room dimensions and ambient light conditions and the guide will help your device selection: http://www.kac.co.uk/EN54-device-chooser.htm

Technical Data

Operating voltage

Current consumption @ 12 V DC

Current consumption @ 24 V DC

Sound level @ 12 V DC

Sound level @ 24 V DC

Frequency of flash

Flash color

Connection terminal

Ambient temperature

Air humidity

Type of protection

Material

Category wall

Mounting height wall

Room width

Category ceiling

Mounting height ceiling

Room diameter

Color

Weight

Specification

Dimensions

12 ... 29 V DC approx. 63.9 mA (@ DIN tone) approx. 69.9 mA (@ DIN tone)

97 dB(A) (@ DIN tone)

102.7 dB(A) (@ DIN tone) approx. 0.5 Hz red

0.5 ... 2.5 mm

2

-25 °C ... 70 °C

< 96 % (non-condensing)

IP21C, IP65 with CWW and accessories

PC/ABS, UL94-V0

W-2,4-6,0

2.4 m

6 m

C-3-8,9 / C-6-8,2

3 m / 6 m

8,9 m / 8,2 m red, similar to RAL 3020 cap: transparent approx. 248 g

EN 54-3 acoustic signaling device

EN 54-23 optical signaling device

Ø: 100 mm H: 98 mm

Ø: 100 mm H: 122 mm (incl. IP base)

Not suitable for use outdoors or in damp areas. Please use therefore the optional bases and accessories (Part No. CWR, PS188, PS189). Use of the deep IP socket reduces the dB output by an average of 4 dB. Replacement for Part No. 766430.

Accessories

CWR Base deep IP 65, red

PS188 Base deep, O-Ring

PS189 Base deep, seal

Combination signaling device EN 54-23 cat. W+C, white flash

As CWSS-RR-S5, but with a white flash.

Combined acoustic/optical alarm device EN 54-23 cat. W+C, red flash, white housing

As CWSS-RR-S5, but in a white housing.

Technical Data

Color white, similar RAL 9003 cap: transparent

Accessories

CWW Base deep IP65, white

PS188 Base deep, O-Ring

PS189 Base deep, seal

CWSS-WW-S5

Combined acoustic/optical alarm device EN 54-23 cat. W+C, white flash, white housing

As CWSS-WR-S5, but in a white housing with white flash.

192 www.hls-austria.com

Alarm Devices

1

CWST-WA-S7

72 mm

97 mm

100 mm

Features

Flat design

Synchronous flash trigger

Low alarm power

1

CWST-RA-S7

Conventional ENscape

Optical alarm signaling device, amber flash

Optical alarm device for wall and ceiling mounting with amber signal flash and flat base.

The device does not comply with EN 54-23.

Technical Data

Operating voltage

Current consumption @ 24 V DC

Frequency of flash

Flash color

Ambient temperature

Air humidity

Type of protection

Material

Color

Weight

Dimensions

12 ... 29 V DC approx. 3 mA (@ DIN tone) approx. 0.5 Hz yellow

-25 °C ... 70 °C

< 96 % (non-condensing)

IP21C, IP65 with CWW and accessories

PC/ABS, UL94-V0

PC, UL94-V0 (Lens) base: white, similar RAL 9003 cap: amber approx. 164 g

Ø: 100 mm H: 72 mm

Ø: 100 mm H: 97 mm (incl. IP base)

Not suitable for use outdoors or in damp areas. Please use therefore the optional bases and accessories (Part No. CWW, PS188, PS189). Replacement for Part No. 766411.

Accessories

CWW Base deep IP 65, white

PS188 Base deep, O-Ring

PS189 Base deep, seal

Optical alarm signaling device, amber flash, red housing

As CWST-WA-S7 but in a red housing.

All tones comply with EN 54-3. Tone configuration takes place via a 6-pin DIP switch. The optical signaling device with amber signal lamp is suitable for applications where a sounder is required as the primary method of alarm, but a supplementary light indicator would also be of benefit.

Technical Data

Type of protection

Material

Color

IP21C, IP65 with CWR and accessories

PC/ABS, UL94-V0

PC, UL94-V0 (Lens) base: red, similar RAL 3020 cap: amber

Not suitable for use outdoors or in damp areas. Please use therefore the optional bases and accessories (Part No. CWR, PS188, PS189).

Accessories

CWR Base deep IP 65, red

PS188 Base deep, O-Ring

PS189 Base deep, seal

8

9

6

7

2

3

4

5

12

13

10

11

14

193

Alarm Devices

CWSS-WA-S7

98 mm

100 mm

122 mm

Features

Approved to EN54-3 for sound

32 approved tones including bell tone

LED technology & advanced optics provides light indication at very low current draw

Synchronisation of flash and sound.

Operates on 12V and 24V systems

Conventional ENscape

Combined acoustic/optical alarm device, red flash, white housing

Combined acoustic and optical alarm signaling device in white housing, and offers a selection of 32 signal tones including the DIN tone and other country-specific tones. All tones comply with EN

54-3. Tone configuration takes place via a 6-pin DIP switch. The optical signaling device with amber signal lamp is suitable for applications where a sounder is required as the primary method of alarm, but a supplementary light indicator would also be of benefit.

The device does not comply with EN 54-23.

Technical Data

Operating voltage

Current consumption @ 24 V DC

Sound level @ 1 m

Flash color

Connection terminal

Ambient temperature

Air humidity

Type of protection

Material

Color

Weight

Specification

Dimensions

12 ... 29 V DC approx. 22 mA (@ DIN tone 7)

107 dB(A) (@ DIN tone 23) red

0.5 ... 2.5 mm 2

-25 °C ... 70 °C

< 96 % (non-condensing)

IP21C, IP65 with CWW and accessories

PC/ABS, UL94-V0 base: white, similar RAL 9003 cap: amber approx. 242 g

EN 54-3 acoustic signaling device

Ø: 100 mm H: 98 mm

Ø: 100 mm H: 122 mm (incl. IP base)

Not suitable for use outdoors or in damp areas. Please use therefore the optional bases and accessories (Part No. CWW, PS188, PS189).

Accessories

CWW Base deep IP 65, white

PS188 Base deep, O-Ring

PS189 Base deep, seal

194 www.hls-austria.com

Alarm Devices

1

CWSS-RR-S3

98 mm

122 mm

100 mm

Features

EN 54-3 compliant

Cat. O under EN 54-23

Synchronous sound and flash trigger

Volume adjustable to 2 levels at the device

Suitable for wall and ceiling mounting

Conventional ENscape

Combined acoustic/optical alarm device EN 54-3, open class, red flash, red housing

Combined acoustic alarm signaling device is EN 54-3 compliant with additional optical display, in red housing, and offers a selection of 32 signal tones including the DIN tone and other country- specific tones. All tones comply with EN 54-3. Tone configuration takes place via a 6-pin DIP switch. Up to two different signal tones may be activated. Signaling device with flat base, suitable for wall and ceiling mounting.

The integrated optical display with red signal flash is only authorized under EN 54-23 in open category O for 24–29 V DC operating voltage. Below 24 V DC, the device is classified as an acoustic signaling device with additional display. To help define your conventional Visual Alarm Devices

(VADs) requirements in line with the EN54-23 standard, we have developed an easy to use online guide. Simply enter the room dimensions and ambient light conditions and the guide will help your device selection: http://www.kac.co.uk/EN54-device-chooser.htm.

Technical Data

Operating voltage

Current consumption @ 12 V DC

Current consumption @ 24 V DC

Sound level @ 12 V DC

Sound level @ 24 V DC

Frequency of flash

Flash color

Connection terminal

Ambient temperature

Air humidity

Type of protection

Material

Color

Weight

Specification

Dimensions

12 ... 29 V DC approx. 15.5 mA (@ DIN tone) approx. 35.4 mA (@ DIN tone)

96.5 dB(A) (@ DIN tone)

102.5 dB(A) (@ DIN tone) approx. 0.5 Hz red

0.5 ... 2.5 mm

2

-25 °C ... 70 °C

< 96 % (non-condensing)

IP 21C, IP 65 with CWR and accessories

PC/ABS, UL94-V0 red, similar RAL 3020 cap: transparent approx. 236 g

EN 54-3 acoustic signaling device

EN 54-23 optical signaling device, (Cat O, 24 ... 29 V

DC)

Ø: 100 mm H: 98 mm

Ø: 100 mm H: 122 mm (incl. IP base)

Not suitable for use outdoors or in damp areas. Please use therefore the optional bases and accessories (Part No. CWR, PS188, PS189). Use of the deep IP socket reduces the dB output by an average of 4 dB. Replacement for Part No. 766240.

Accessories

CWR Base deep IP 65, red

PS188 Base deep, O-Ring

PS189 Base deep, seal

CWSS-WR-S3

Combined acoustic/optical alarm device EN 54-3, open class, red flash, white housing

As CWSS-RR-S3, but in a white housing.

8

9

6

7

2

3

4

5

12

13

10

11

14

195

Alarm Devices

1

CWR

1

CWW

1

PS188

1

PS189

1

SC076

Conventional ENscape

Base deep IP 65, red

Base, red, for ENscape signaling device with IP 65 protection rating and sm cable entry.

Technical Data

Type of protection

Material

Color

Weight

Dimensions

5 pcs

IP65 (with accessories)

PC/ABS, UL94-V0 red, similar to RAL 3020 approx. 47 g

Ø: 100 mm H: 53 mm

Accessories

PS 188 Base deep, O-Ring

PS 189 Base deep, seal

SC076 Grounding bridge for deep base

Base deep IP 65, white

As CWR, but white color.

Technical Data

Color

5 pcs white, similar to RAL 9003

O-Ring for deep base

Replacement O-ring for use with deep CWR or CWW base.

Technical Data

Material

Color

5 pcs

MBR 70 black

Seal for deep base

Seal for use with deep CWR or CWW base for IP 65 protection rating.

Technical Data

Material

Color

5 pcs closed-cell neoprene black

Ground jumper for deep base

Grounding strap for use with deep CWR or CWW base.

Technical Data

Material

5 pcs

Stainless steel

196 www.hls-austria.com

Alarm Devices Intelligent Addressable IQ8Alarm

32

60

75

90

112

25

60

75

112

Features

Completely bus supplied alarm device

Powered loop compatible

Low power consumption

5 different signaling device types - acoustic - optical- acoustic / optical- acoustic / optical- acoustic / optical / speech

Multilingual speech alarm in 5 different languages

Alarm signaling, evacuation, and test alarm can each be programmed in different languages

Up to 32 alarm devices for each powered loop

Each alarm device has built-in isolator

Individual control of the sounder and beacon

Tones can be used for other purposes in addition to warning of fire, making the device ideal for use in schools etc.

Soft start option, ideal for hospitals and nursing homes

Acoustic alarm signaling:

Acoustic pressure up to 99 dB(A) @ 1 m

Volume programmable in 8 steps via tools 8000

Up to 26 different languages are available

20 different signaling tones, including DIN tone

Speech alarm, 5 pre-programmed alarm texts and other country-typical alarm signals

Optical alarm signaling:

Flash intensity equivalent to 3W Xenon flash light

Light intensity: max. 3.87 cd effective, max. 24 cd peak

IQ8Alarm enables IQ8Quad detector application with integrated alarm signaling and other advantages. No matter whether multilingual speech alarm, flexible signal combination or user-friendly programming interfaces, all these features are also available when using IQ8Alarm.

The IQ8Alarm range offers distinct advantages, which will surely convince every user straight away.

Advantages with IQ8Alarm at a glance:

Simple programming enabled by a standardized programming interface for all IQ8Systems

(IQ8Quad + IQ8Alarm) alarm signaling devices

-Voltage supply on the loop

-Time-tested, unobtrusive design

Signaling device in compliance with EN 54 with 20 different signaling tones including DIN tone in compliance with DIN 33404-3

On the following pages, you will find more detailed information about IQ8Alarm features.

Please consider:

- Admissible maximum loop length

- Admissible maximum number of single alarm device types

- Maximum number of 127 bus devices for each loop

Systems requirements:

FACP IQ8Control from version V3.04

FACP FlexES Control esserbus-Plus functionality

Programming software tools 8000 from version V1.09

Attention - an operation with the FACP'S 8000 C/M is not possible!!!

For upgrading 8000 C/M control units, IQ8Lumivox signaling devices must be used. If required, please contact our returns department.

For checking the battery capacity of FACP, the value “quiescent current @ FACP battery“ can be added.

8

9

6

7

2

3

4

5

12

13

10

11

14

197

Alarm Devices Intelligent Addressable IQ8Alarm

Intelligent Addressable IQ8Alarm

Country code acc. to ISO

3166 -Alpha-2

Language code acc. to ISO 639-1

Evacuation 1

Germany

(DE) de

Dies ist ein

Feueralarm. Bitte verlassen Sie das

Gebäude umgehend über die nächsten Fluchtwege. Die Feuerwehr ist alarmiert.

Great Britain

(GB) en

This is a fire alarm.

Please leave the building immediately by the nearest available exit.

France

(FR) fr

Evacuation 2

Achtung, Achtung!

Dies ist eine Gefahrenmeldung. Bitte verlassen Sie das

Gebäude über die nächsten

Ausgänge.

Alarm

Achtung, im Gebäude ist eine

Gefahrensituation gemeldet worden.

Bitte bleiben Sie ruhig, und warten

Sie auf weitere

Anweisungen.

Attention please.

This is an emergency. Please leave the building by the nearest available exit.

An incident has been reported in the building. Please await further instructions.

Ceci est une alarme incendie,veuillez

évacuer immédiatement les locaux par la sortie la plus proche.

Votre attention s'il vous plaît, ceci est une alarme. Veuillez

évacuer les locaux par la sortie la plus proche.

Un incident est signalé dans le batiment. Merci de garder votre calme et attendez les prochaines instructions.

Test-message All-Clear

Dies ist eine

Testdurchsage.

Die Gefahrensituation ist jetzt behoben. Wir entschuldigen uns für jegliche

Unannehmlichkeiten.

This is a test message.

No action is required.

The emergency is now cancelled. We apologize for any inconvenience.

Ceci est un test.

L'alarme est à présent annulée.

Veuillez nous excuser pour le désagrément.

Spain

(ES)

Italy

(IT) es it

Esto es una alarma de incendio.

Abandonen por favor el edificio inmediatamente por la salida de evacuación más cercana.

Attenzione.

Allarme incendio.

Abbandonare l'edificio tramite l'uscita di emergenza più vicina.

Atención. Esto es una emergencia.

Por favor abandonen el edificio por la salida de evacuación más cercana.

Attenzione.

Allarme in corso.

Vi preghiamo di recarvi presso l'uscita di emergenza più vicina.

Atención, se ha reportado un incidente en el edificio.

Aguarden por favor otras instrucciones.

Attenzione.

E' stato rilevato un allarme.Ulteriori disposizioni vi verranno comunicate appena possibile.

Esto es un mensaje de prueba.

No se requiere ninguna acción.

La emergencia ha sido cancelada.

Pedimos disculpas por las molestias causadas.

Attenzione.

E' in corso una prova di allarme.

Non è richiesta alcuna azione.

Attenzione. Cessato allarme.La situazione di normalità è stata ripristinata.

Standard speech messages of IQ8Quad detectors and IQ8Alarm - for other languages also refer to the appendix!

10

11

8

9

12

6

7

4

5

No.

Description

1

2

3

Frequency

School bell

FP 1063.1 Telecoms

BS 5839 Pt1

BS 5839 Pt1 complex

Alternating 800 / 970 Hz at 2 Hz

Alternating 800 / 970 Hz at 1 Hz

BS 5839 Pt1

BS 5839 Pt1

Intermittent 970 Hz at 1 Hz 0.5 sec.

Intermittent 2850 Hz at 1 Hz 0.5 sec.

BS 5839 Pt1

BS 5839 Pt1

Intermittent 970 Hz 1/4 sec. ON - 1 sec. OFF

Continuous 970 Hz

Sweep tone 800 Hz tp 970 Hz at 7 Hz BS 5839 Pt1

BS 5839 Pt1

DIN Tone

DIN 33404 Part 3

1200 - 500 Hz at 1 Hz

French fire sound

Sweep tone 800 Hz to 970 Hz at 1 Hz

554 Hz / 100 ms + 440 Hz / 400 ms + 10 %

NL - Slow Whoop 500 Hz - 1200 Hz at 3.5 sec. break of 0.5 sec.

13 US - Horn Continuous 485 Hz

14

15

16

17

18

19

20

US - Horn with

Temporal Pattern

US - March

Time

US - Slow

Whoop

US - Siren

US - Hi/Lo

US - NFPA

Whoop

IMO

GA-Signal

Intermittent 485 Hz

(0,5 sec. ON; 0.5 sec. OFF; 3 times; 1.5 sec. OFF; Repeat)

Alternating 485 Hz

(0,25 sec. ON; 0.25 sec. OFF; Repeat)

Sweep tone 500 Hz to 1200 Hz

(4.0 sec. ON; 0.5 sec. OFF; Repeat)

Sweep tone 600 Hz to 1200 Hz

(1,0 sec. ON, Repeat)

Alternating 100 Hz / 800 Hz

(0.25 sec. ON; Alternate; 0.25 sec. ON; Alternate; Repeat)

Sweep tone 422 Hz to 775 Hz

(upwards sweep 0.85 sec.; 3 times; 1 sec. OFF; Repeat)

Intermittent 800 Hz (1,0 sec. ON; 1,0 sec.

OFF: 7 times; 2.0 sec. ON: 2.0 sec. OFF; Repeat)

IQ8Quad detectors and IQ8Alarm tone table

Pulse rate complex f f f f f

0.25 sec.

0.25 sec.

0.5 sec.

0.5 sec.

0.5 sec.

0.5 sec.

0.5 sec.

0.5 sec.

0.25 sec.

1.0 sec.

f

10 ms f f

1.0 sec.

f f

1.0 sec.

0.4 sec.

0.1 sec.

f

3.5 sec.

0.5 sec.

f f f f

0.5 sec.

0.5 sec.

0.25 sec.

0.25 sec.

4.0 sec. 0.5 sec.

1.0 sec.

f f

0.25 sec.

0.25 sec.

0.85 sec.

f f

1.0 sec.

1.0 sec.

1.5 sec.

1.5 sec.

1.5 sec.

1.0 sec.

t t t t t t t t t t t t t t t t t t t

198 www.hls-austria.com

Alarm Devices Intelligent Addressable IQ8Alarm

IQ8Alarm - Acoustical Alarm Devices

Features

Completely bus supplied alarm device

Powered loop compatible

Low power consumption

Up to 32 alarm devices for each powered loop

Each alarm device has built-in isolator

Tones can be used for other purposes in addition to warning of fire, making the device ideal for use in schools etc.

Soft start option, ideal for hospitals and nursing homes

Acoustic alarm signaling (dependent on type):

Acoustic pressure up to 99 dB(A) @ 1 m

Volume programmable in 8 steps via tools 8000

Up to 26 different languages are available

20 different signaling tones, including DIN tone

Multilingual speech alarm in 5 different languages

Alarm signaling, evacuation, and test alarm can each be programmed in different languages

Speech alarm, 5 pre-programmed alarm texts and other country-typical alarm signals

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Quiescent current @ FACP battery

Load factor

Sound level

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Weight

Specification

Dimensions

Declaration of Performance

1

807205

8 ... 42 V DC (via powered loop) approx. 55 μA approx. 300 μA @ 42 V

3

97 dB(A) +/- 2 dB @ 1 m

-5 °C ... 50 °C

-10 °C ... 55 °C

< 95 % (non-condensing)

IP 30

(IP 65 with socket 806201 / 806202)

ABS plastic approx. 300 g

EN 54-3 acoustic signaling device

EN 54-3 acoustic speech signaling device (Q2/2011)

Ø: 112 mm D: 75 mm

Ø: 112 mm D: 90 mm (with IP 65 base)

DoP-20213130701

IQ8Alarm/So signaler with isolator, white

Approval: VdS

Addressable, completely bus supplied and short circuit / open circuit resilient alarm signaling device in compliance with EN 54-3 with up to 20 different programmable signaling tones including

DIN tone in accordance with DIN 33404 Part 3 for acoustic alarm signaling. The volume can be set to 8 different levels. Its flat design enables optimum adaptation to the environments. It is made of shock and scratch resistant plastic. Optionally, bases Part No. 806201 and 806202 with side cable entry and weatherproof protection can be installed.

Technical Data

Color

Specification white, similar to RAL 9010

EN 54-3 acoustic signaling device

EN 54-3

Accessories

806201 IP65 base, white

1

807206

8

9

6

7

2

3

4

5

12

13

10

11

14

IQ8Alarm/So signaler with isolator, red

Approval: VdS

Same as 807205, but red.

Technical Data

Color

Specification red, similar to RAL 3020

EN 54-3 acoustic signaling device

EN 54-3

Accessories

806202 IP65 base, red

199

Alarm Devices

1

807322

1

807322.SV98

Intelligent Addressable IQ8Alarm

IQ8Alarm/Sp signaler with isolator, white

Approval: VdS

Same as 807205, but with additional speech alarm function.

Technical Data

Color

Specification white, similar to RAL 9010

EN 54-3 acoustic signaling device

EN 54-3 acoustic speech signaling device (Q2/2011)

Programmed with an individual selection of up to 5 national languages

Accessories

806201 IP 65 base, white

IQ8Alarm/Sp signaler with isolator, white, composed version

Approval: VdS

Same as 807322, but with individual text and/or sounds. The maximum recording time per device is 169 seconds.

Technical Data

Specification EN 54-3

EN 54-3

When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in

“Order form for individual combination of languages” printed in the appendix.

Cancellations or returns are not possible.

Programmed with an individual selection of up to 5 national languages

Accessories

806201 IP65 base, white

200 www.hls-austria.com

Alarm Devices

1

807332

1

807332.SV98

1

807332.SV99

Intelligent Addressable IQ8Alarm

IQ8Alarm/Sp signaler with isolator, red

Approval: VdS

Same as 807322, but red.

Technical Data

Color

Specification red, similar to RAL 3020

EN 54-3 acoustic signaling device

EN 54-3 acoustic speech signaling device (Q2/2011)

Programmed with an individual selection of up to 5 national languages

Accessories

806202 IP65 base, red

IQ8Alarm/Sp signaler with isolator, red, composed version

Approval: VdS

Same as 807322.SV98, but with an individual combination of up to 5 languages, see special order form in the appendix.

Technical Data

Specification EN 54-3

EN 54-3

When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in

“Order form for individual combination of languages” printed in the appendix.

Cancellations or returns are not possible.

Accessories

806202 IP65 base, red

IQ8Alarm/Sp signaler with isolator, red, customized version

Approval: VdS

Same as 807322, but with individual text and/or sounds. The maximum recording time per device is 169 seconds.

Technical Data

Specification EN 54-3

EN 54-3

When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in

“Order form for individual combination of languages” printed in the appendix.

Costs for the recording of customer specific texts and/or tones can be obtained on request.

Cancellations or returns are not possible.

Accessories

806202 IP65 base, red

8

9

6

7

2

3

4

5

12

13

10

11

14

201

Alarm Devices Intelligent Addressable IQ8Alarm

IQ8Alarm - Combined Alarm and Speech Signaling Devices

Features

Completely bus supplied alarm device

Powered loop compatible

Low power consumption

Up to 32 alarm devices for each powered loop

Each alarm device has built-in isolator

Tones can be used for other purposes in addition to warning of fire, making the device ideal for use in schools etc.

Soft start option, ideal for hospitals and nursing homes

Acoustic alarm signaling (dependent on type):

Acoustic pressure up to 99 dB(A) @ 1 m

Volume programmable in 8 steps via tools 8000

Up to 26 different languages are available

20 different signaling tones, including DIN tone

Multilingual speech alarm in 5 different languages

Alarm signaling, evacuation, and test alarm can each be programmed in different languages

Speech alarm, 5 pre-programmed alarm texts and other country-typical alarm signals

Optical alarm signaling:

Flash intensity equivalent to 3W Xenon flash light

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Quiescent current @ FACP battery

Load factor

Sound level

Frequency of flash

Lighting energy

Luminous intensity

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Weight

Specification

Dimensions

Declaration of Performance

8 ... 42 V DC (via powered loop) approx. 55 μA approx. 300 μA @ 42 V

3

97 dB(A) +/- 2 dB @ 1 m approx. 3 Hz approx. 3 Y max. 24.4 cd peak/ 4.1 cd effektive (red flash)

-10 °C ... 50 °C

-10 °C ... 55 °C

< 95 % (non-condensing)

IP 30

(IP 65 with socket 806201 / 806202)

ABS plastic approx. 300 g

EN 54-3 acoustic signaling device

EN 54-3 acoustic speech signaling device (Q2/2011)

Ø: 112 mm D: 75 mm

Ø: 112 mm D: 90 mm (with IP 65 base)

DoP-20213130701

1

807224 IQ8Alarm/FSo signaler with isolator, red

Approval: VdS

Addressable, completely bus supplied and short circuit / open circuit resilient alarm signaling device in compliance with EN 54-3 with up to 20 different programmable signaling tones including

DIN tone in accordance with DIN 33404 Part 3 for acoustic and optical alarm signaling. The volume can be set to 8 different levels. Its flat design enables optimum adaptation to the environ ments. It is made of shock and scratch resistant plastic. Optionally, bases (Part no. 806201 white or 806202 red) with side cable entry and weatherproof protection (IP65) can be installed.

Technical Data

Luminous intensity

Color

Specification max. 24.4 cd peak/ 4.1 cd effektive (red flash) red, similar to RAL 3020

EN 54-3 acoustic signaling device

EN 54-3

Accessories

806202 IP65 base, red

202 www.hls-austria.com

Alarm Devices

1

807372

1

807372.SV98

1

807372.SV99

Intelligent Addressable IQ8Alarm

IQ8Alarm/FSp signaler with isolator, red

Approval: VdS

Same as in 807224, but with programmed speech alarm for powered loop connection.

Technical Data

Luminous intensity

Color

Specification max. 24.4 cd peak/ 4.1 cd effektive (red flash) red, similar to RAL 3020

EN 54-3 acoustic signaling device

EN 54-3 acoustic speech signaling device (Q2/2011)

Programmed with 5 languages: German, English, French, Spanish and Italian.

Accessories

806202 IP65 base, red

IQ8Alarm/FSp signaler with isolator, red, composed version

Approval: VdS

Same as 807372, but with an individual combination of up to 5 languages, see special order form in the appendix.

Technical Data

Color

Specification red, similar to RAL 3020

EN 54-3

EN 54-3

When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in

“Order form for individual combination of languages” printed in the appendix.

Cancellations or returns are not possible.

Programmed with 5 languages in accordance with composed combination.

Accessories

806202 IP65 base, red

IQ8Alarm/FSp signaler with isolator, red, customized version

Approval: VdS

Same as 807372, but with individual texts and/or sounds. The maximum recording time per device is 169 seconds.

Technical Data

Color

Specification red, similar to RAL 3020

EN 54-3

EN 54-3

When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in

“Order form for individual combination of languages” printed in the appendix.

Costs for the recording of customer specific texts and/or tones can be obtained on request.

Cancellations or returns are not possible.

Programmed according to customer specifications.

Accessories

806202 IP65 base, red

8

9

6

7

2

3

4

5

12

13

10

11

14

203

Alarm Devices Intelligent Addressable IQ8Alarm

IQ8Alarm - Optical Alarm Signaling Devices

1

807212 IQ8Alarm/F signaler with isolator, amber flash

Approval: VdS

Addressable, completely bus supplied and short circuit / open circuit resilient alarm signaling device for optical alarm signaling. Its flat and unobtrusive design enables optimum adaptation to the environments.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Quiescent current @ FACP battery

Load factor

Frequency of flash

Lighting energy

Luminous intensity

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

Declaration of Performance

806201 IP65 base, white

8 ... 42 V DC (via powered loop) approx. 55 μA approx. 300 μA @ 42 V

3 approx. 3 Hz approx. 3 Y max. 24 cd peak/ 3.87 cd effective

-10 °C ... 50 °C

-10 °C ... 55 °C

< 95 % (non-condensing)

IP 30

IP 65 (with base 806201/806202)

ABS plastic base: white, similar to RAL 9010 cap: amber approx. 300 g

Ø: 112 mm D: 75 mm

Ø: 112 mm D: 90 mm (with IP 65 base)

DoP-20213130701

1

807213 IQ8Alarm/F signaler with isolator, blue/green/white flash

Approval: VdS

Same as 807212, but transparent, blue and green.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Quiescent current @ FACP battery

Load factor

Frequency of flash

Lighting energy

Luminous intensity

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

Declaration of Performance

Replacement: 807214WW

8 ... 42 V DC (via powered loop) approx. 55 μA approx. 300 μA @ 42 V

3 approx. 3 Hz approx. 3 Y transparent: max. 17.39 cd peak/ 2.16 cd effektive blue: max 5,06 cd peak/0,62 cd effektive green: max. 2,72 cd peak/0,33 cd effektive

-10 °C ... 50 °C

-10 °C ... 55 °C

< 95 % (non-condensing)

IP 30

IP 65 (with base 806201/806202)

ABS plastic base: white, similar to RAL 9010 cap: blue, green, transparent approx. 300 g

Ø: 112 mm D: 75 mm

Ø: 112 mm D: 90 mm (with IP 65 base)

DoP-20213130701

806201 IP65 base, white

204 www.hls-austria.com

Alarm Devices Intelligent Addressable IQ8Alarm

1

807214WW

Features

Completely bus supplied alarm device

Powered loop compatible

Low power consumption

Up to 32 alarm devices for each powered loop

Each alarm device has built-in isolator

EN 54-23 compliant

W category

Synchronous flash control

Up to 5 m, room width

Optical alarm signaling device IQ8Alarm EN 54-23 Kat. W, white flash

Approval: requested

Optical signaling device compliant with EN 54-23 for wall mounting with white signal flash and flat base. The signaling device is suitable for square signal ranges W-2.4-5.0.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Load factor

Frequency of flash

Flash color

Ambient temperature

Air humidity

Type of protection

Material

Category wall

Mounting height wall

Room width

Color

Weight

Specification

Dimensions

Replacement for 807213

8 ... 42 V DC approx. 55 μA

3 approx. 0.5 Hz(factory) /1 Hz white

-25 °C ... 70 °C

< 95 % (non-condensing)

IP 41

Flash lamp PC

W-2,4-5,0 (factory)

2.4 m

5 m white, similar to RAL 9010 cap: transparent approx. 275 g (with base)

EN 54-23 optical alarm signaling device

Ø: 112 mm H: 75 mm

807214RR

Optical alarm signaling device IQ8Alarm EN 54-23 Kat. W, red flash

Approval: requested

1

Features

Completely bus supplied alarm device

Powered loop compatible

Low power consumption

Up to 32 alarm devices for each powered loop

Each alarm device has built-in isolator

EN 54-23 compliant

W category

Synchronous flash control

Up to 5 m, room width

Optical signaling device compliant with EN 54-23 for wall mounting with red signal flash and flat base. The signaling device is suitable for square signal ranges W-2.4-5.0.

Technical Data

Operating voltage

Quiescent current @ 19 V DC

Load factor

Frequency of flash

Flash color

Ambient temperature

Air humidity

Type of protection

Material

Category wall

Mounting height wall

Room width

Color

Weight

Specification

Dimensions

Replacement for 807214

8 ... 42 V DC approx. 55 μA

3 approx. 0.5 Hz(factory) /1 Hz red

-25 °C ... 70 °C

< 95 % (non-condensing)

IP 41

Flash lamo PC

W-2,4-5,0 (factory)

2.4 m

5 m red, similar to RAL 3020 cap: transparent approx. 275 g (with base)

EN 54-23 optical alarm signaling device

Ø: 112 mm H: 75 mm

8

9

6

7

2

3

4

5

12

13

10

11

14

205

Alarm Devices Intelligent Addressable IQ8Alarm

Accessories IQ8Alarm

1

806201 IQ8Alarm IP 65 base, white

White base, for IQ8Alarm device with protection type IP65 and surface mount cable entry.

Technical Data

Type of protection

Color

IP 65 white, similar to RAL 9010

1

806202

1

767800

IQ8Alarm IP 65 base, red

Red base, for IQ8Alarm device with protection type IP65 and surface mount cable entry.

Technical Data

Type of protection

Color

IP 65 red, similar to RAL 3020

Mounting bracket for lintel installation

Mounting bracket for all bases/detectors of the IQ8Quad group, series 9x00, RAS 2103 for

IQ8Alarm including all alarm devices.

The distance between the mounting holes is 6 cm and the diameter is about 5 mm. Detector side L x W 175 x 90 mm; Wall side H x W 65 x 90 mm.

Technical Data

Material

Color

Mounting bracket and installation material aluminum white, similar to RAL 9010

206 www.hls-austria.com

Alarm Devices Conventional

Intrinsically Safe

1

045040 Ex signaling device DS10, 12 V DC

Approval: VdS (FDT)

Features

9 tone sequences can be programmed:

Continuous tone

Alternating tone

Intermittent tone

Siren

Fire alarm (different national regulations taken into account)

The sound generator is especially suitable for hazardous industrial areas (zone 2 and 22). The robust aluminum die-cast housing is resistant to chemicals and environmental factors. The DS10 complies with the technical requirements of DIN 33404 - 3 "hazard signals for workplaces".

Technical Data

Ex-category

Explosion protection

Operating voltage

Current consumption @ 12 V DC

Sound level

Ambient temperature

Storage temperature

Air humidity

Type of protection

Material

Color

Weight

Specification

Dimensions

II 3GD

EEx nA II T5

11 ... 14 V DC

10 V DC approx. 300 mA

110 dB (A) +- 3 dB (A)

-25 °C ... 55 °C

-40 °C ... 70 °C

< 90 % (non-condensing)

IP 66, IP 67 aluminum die cast red, similar to RAL 3000 approx. 1.95 kg

EN 54-3

W: 150 mm H: 150 mm D: 143 mm

According to the conformity declaration, the alarm devices can be used in zones 2 and 22.

See tone table on our download website.

1

766253 Ex sounder, 12 V DC

KEMA 99 ATEX 7906 design certificate

Features

32 tone sequences can be programmed:

Quartz controlled sound synchronization

ATEX approved

LM6 aluminum die-cast housing

Self-extinguishing aluminum cone, similar to UL

94 VO

The ex sounder is especially suitable for application in hazardous areas at industrial workplaces category 2G or 3G (formerly zones 1 and 2) and complies with the technical requirements of DIN

33404 - 3. The robust aluminum die-cast housing is resistant to chemicals and environmental factors.

Technical Data

EC-type examination certificate

Explosion protection

Operating voltage

Current consumption

Current consumption @ 12 V DC

Sound level

Ambient temperature

Storage temperature

Air humidity

Type of protection

Material

Color

Weight

Dimensions

KEMA 99ATEX 7906

II 2G Ex de IIC T4

12 V DC typ. 195 mA; approx. 195 mA

110 dB(A) ± 3 dB @ 1 m (depending on signaling type)

-50 °C ... 55 °C

-50 °C ... 70 °C

< 90 % (non-condensing)

IP67 aluminum die cast LM6 red, similar to RAL 3000 approx. 3.16 kg

Ø: 181 mm L: 263 mm

According to the conformity declaration, the alarm devices can be used in zones 2 and 22.

See tone table on our download website.

8

9

6

7

2

3

4

5

12

13

10

11

14

207

Alarm Devices Remote Indicators

Remote Indicators

Features

Shapely, light-weight and compact design

Prism with all around 180° visible LEDs with a wide area of illumination and high on/off contrast

These indicators are used primarily for signaling alarms of smoke detectors installed above suspended ceilings, between floors or in other inaccessible locations. The indicators have an elegant plastic housing with a clearly visible illuminated field. It comprises two parts - the base which is installed onto a wall or soffit and the lid which is fitted to the base with a clip plug.

Cable length of the remote indicators to detector base or voltage supply max. 100 m.

1

781814

Features

3 continuously or pulsed LEDs

Power-saving compact indicator

Remote indicator for Series 9000, 9200 and IQ8Quad, red

Red prism is continuously or pulsed illuminated by 3 LEDs.

Technical Data

Operating voltage

Current consumption

Alarm display

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

Detectors series IQ8Quad

1.8 V DC approx. 9 mA

3 red LEDs

-20 °C ... 70 °C

-35 °C ... 85 °C

< 95 % (non-condensing)

IP 50

ABS plastic white, similar to RAL 9010 approx. 60 g

W: 85 mm H: 82 mm D: 27 mm

- Standard base Part No. 805590 required for series IQ8Quad

- max. 1 remote indicator per detector

- max. 60 remote indicators per zone (with max. 30 detectors)

- Indicator flashes if activated (Pulse frequency approx.1 Hz)

1

801824

Features

4 pulsed LEDs

Ultra power-saving compact indicator

Powered loop alarm device

Remote indicator esserbus-PLus for detector series 9200 and IQ8Quad, red

Red prism is illuminated by 4 pulsed LEDs for operation on esserbus and esserbus-PLus to increase the energy efficiency.

Technical Data

Operating voltage

Quiescent current @ 12 V DC

Alarm current

Frequency of flash

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

Detectors series IQ8Quad

8 ... 42 V DC approx. 0.007 mA

150 µA approx. 1.5 Hz

-20 °C ... 70 °C

-35 °C ... 85 °C

< 95 % (non-condensing)

IP 50

ABS plastic white, similar to RAL 9010 approx. 60 g

W: 85 mm H: 82 mm D: 27 mm

- Standard base Part No. 805590 required for series IQ8Quad

- max.3 remote indicator per detector

- max. 103 remote indicators per loop

208 www.hls-austria.com

Door Release System

Automatic Door Systems

Door Holding Devices

Triggering Devices

8

9

6

7

2

3

4

5

10

11

210-212

213-217

218

12

13

14

209

Door Release System Automatic Door Systems

Features

Low profile design

Easy cable entry & exit

Electronic connection via a terminal clamp

Door retainers have an integrate release button

The door retainer can be mounted to the wall, to the floor or to the ceiling behind the door. Due to the large product range almost any requirement profile can be met

The counterpart is the armature (keeper plate) which is mounted on the door

Door retainer magnets are delivered with a suitable keeper plate

Electrical Protection IP54

Anti-remanence pin

Integrated reverse polarity and spark suppression diode

Plastic parts consist of Bayblend material with

30% PA6 glass fiber

Automatic door closing systems for the demarcation of buildings and objects in closed fire compartments for the protection of people and valuables in case of fire.

Automatic door systems consist of triggering devices and locking devices.

In the event of fire, signals created by automatic triggering device cause a release of locking device. Actuation by the manual triggering device also leads to release of locking device.

Fire doors close and prevent the spreading of fires and of any present smoke to bordering areas in a building. This way, fire and dangerous fire aerosols are contained and human life as well as valuables are protected.

Locking device consists of e.g. a clamping magnet with corresponding anchor plate and/ or of an automatic door closer. Triggering device consists of a controller, fire detector and release key pushbutton (manual triggering device).

In terms of building directives in Germany, automatic door systems are subject to approval by

Deutschen Institut for Bautechnik in Berlin and need a system authorization (for this, see certificates of approval from the DIBt).

The door holding magnets from Honeywell product line are generally vacuum cast and feature

IP64 protection class by the basic device.

Door holding magnets are fitted with an integral manual release button, allowing the door to be closed without operating the fire alarm.

All the electromagnets are designed to comply with the latest requirements of EN1155 and DIN

EN14637.

210 www.hls-austria.com

Door Release System

Connection Examples

Release pushbutton

Release pushbutton

Release pushbutton

Automatic Door Systems

10

11

12

13

14

8

9

6

7

2

3

4

5

211

Door Release System Automatic Door Systems

Release pushbutton

Release pushbutton

212 www.hls-austria.com

Door Release System Door Holding Devices

Holding Magnets with 400 N Holding Force

The door holding magnets from this product line are generally vacuum cast and feature IP65 protection class by the basic device. The magnets are quality-controlled and are subjected to sampling tests twice per year by the VdS. In addition, all dimensions are in accordance with European specifications and tested in compliance with the EN1155.

1

960120

Door magnet with release button incl. flexible anchor, 400 N

Release button changeable to the left or right from the base. Cable entry is possible from behind the unit, as well as through the base, left or right side using included grommets.

In combination with angled mounting plates the unit can be installed to either floor or wall.

Integrated reverse-polarity protection diode and spark supressing diode.

Technical Data

Operating voltage

Power consumption

Type of protection

Dimensions

CE certificate

24 V DC

1.6 W

IP54 (magnet); IP42 (connection)

W: 85 mm H: 110 mm D: 38 mm

0786-CPD-20435

1

960121

1

960122

1

960130

1

960124

Door magnet with distance pipe incl. flexible anchor, 400 N, 175 mm

Approval: VdS

Magnet rotary head is fully rotational and is thus suitable for both floor and wall installations.

Customer may shorten distance pipe if necessary.

Integrated reverse-polarity protection diode and spark supressing diode.

Manual release button on pipe available.

Wall distance: 175 mm

Floor distance: 150 mm

Technical Data

Operating voltage

Power consumption

Type of protection

Dimensions

CE certificate

24 V DC

1.6 W

IP54 (magnet); IP42 (connection)

W: 90 mm H: 80 mm Distance: 150/175 mm

0786-CPD-20435

Door magnet with distance pipe incl. flexible anchor, 400 N, 325 mm

As 960121, but with wall distance 325 mm or floor distance 300 mm.

Technical Data

Dimensions W: 90 mm H: 80 mm Distance: 300/325 mm

Door magnet with distance pipe incl. flexible anchor, 400 N, 475 mm

As 960121, but with wall distance 475 mm or floor distance 450 mm.

Technical Data

Dimensions W: 90 mm H: 80 mm Distance: 450/475 mm

Door magnet w/o release button incl. flexible anchor, 400 N

Version with terminal clamp and installation plate.

Integrated reverse-polarity protection diode and spark supressing diode.

Suitable for wall installation.

Technical Data

Operating voltage

Power consumption

Type of protection

Dimensions

CE certificate

24 V DC

1.6 W

IP54 (magnet); IP42 (connection)

W: 55 mm H: 55 mm D: 33 mm

0786-CPD-20435

10

11

12

13

14

8

9

6

7

2

3

4

5

213

Door Release System Door Holding Devices

Holding Magnets with 490 N Holding Force

1

960126

Wall mounted door magnet w/o release button, 490 N

Wall mounted direct current door magnet.

Technical Data

Operating voltage

Power consumption

Dimensions

Approvals

24 V DC

1.5 W

W: 75 mm H: 116 mm D: 43 mm

EN155, CPR, EN14637

1

767010 Door retainer DH50-N490-WM

Door retainer with polarity reversal protection and connecting terminal including fixing plate for wall mounting.

Technical Data

Operating voltage

Power consumption

Dimensions

24 V DC

1.5 W

Ø: 50 mm H: 30 mm

Holding Magnets with 800 N Holding Force

1

960119

Door magnet with release button incl. flexible anchor, 800 N

Release button changeable to the left or right from the base. Cable entry is possible from behind the unit, as well as through the base, left or right side using included grommets.

In combination with angled mounting plates the unit can be installed to either floor or wall.

Integrated reverse-polarity protection diode and spark supressing diode.

Technical Data

Operating voltage

Power consumption

Type of protection

Dimensions

Approvals

24 V DC

2.2 W

IP54 (magnet); IP42 (connection)

W: 85 mm H: 110 mm D: 38 mm

EN155, CPR, EN14637

214 www.hls-austria.com

Door Release System

1

960127

Door Holding Devices

Wall and floor swivel bracket for door magnet 960119 and 960120, angled,

150 mm

This swivel bracket is specially intended for use with 960120 door magnet and thus allows floor or wall installa tion by means of distance pipe.

Technical Data

Dimensions

Weight

W: 100 mm H: 150 mm D: 140 mm approx. 0.65 kg

1

960128

1

960129

Explosion-Proof

767153

Wall and floor swivel bracket for door magnet 960119 and 960120, angled, 300 mm

As 960127, but with 300 mm pipe length.

Technical Data

Dimensions

Weight

W: 100 mm H: 300 mm D: 140 mm approx. 1 kg

Floor mounted bracket for door magnet 960119 and 960120

This brackt is especially intended for 960119 and 960120 door magnet. Thus a parallel door installation is possible. Magnet can either be installed within the side panels (to protect from vandalism) or adjacent to the side panels (standard). Due to the increased gauge of steel used, this base is suitable for heavy use (schools etc).

Technical Data

Dimensions

Weight

W: 95 mm H: 128 mm D: 80 mm approx. 0.65 kg

Ex door magnet, 1588 N

Approval: VdS, TÜV ATEX

Explosion-proof and encapsulated holding magnet for explosion endangered areas.

Wall-mounted with cable entry via cable gland.

Technical Data

Operating voltage

Power consumption

Holding force

Ambient temperature

Ex-category

Explosion protection

Type of protection

Dimentions

EC-type examination certificate

24 V DC

3 W

1588 N

0 °C ... 35 °C

II 2G (gas) and 2D (dust)

EExme II T6 (gas) and T73°C IP6X (dust)

IP56

W: 130 mm H: 117 mm D: 106 mm

TÜV01 ATEX 1778 X

Delivery without anchor plate.

on demand

Approved anchor plates must be used in EX zones.

10

11

12

13

14

8

9

6

7

2

3

4

5

215

Door Release System

Keeper Plates

1

960110

Door Holding Devices

Flexible keeper plate for door magnets, Ø 55 mm

The flexible keeper plate is designed for doors with an angle. The anchor plate is 60° adjustable and fixable in each direction through an articulated joint. The surface is grounded and protected against corrosion.

Technical Data

Weight

Dimensions approx. 0.15 kg

Ø: 55 mm W: 55 mm H: 55 mm D: 50 mm

1

767030 Anchor plate DH50-AP-S

Fixing plate for door retainers with a diameter of 50 mm.

Technical Data

Dimensions Ø: 50 mm W: 55 mm H: 55 mm D: 18 mm

767031 Anchor plate DH70-AP-S

As 767030, but with Ø 70 mm anchor plate.

Technical Data

Dimensions Ø: 70 mm W: 75 mm H: 75 mm D: 26 mm

216 www.hls-austria.com

Door Release System

Power Supply Units for Door Release System

1

765612

Door Holding Devices

Power supply unit for automatic door release systems, 12 V, 3 A

Surface mount housing for fire door release systems.

Technical Data

Rated voltage

Rated frequency

Output voltage

Output current

Ambient temperature

Storage temperature

Air humidity

Type of protection

Housing

Color

Weight

Dimensions

230 V AC/115 V AC

50 ... 60 Hz

12 V DC max. 3 A

-10 °C ... 40 °C

-20 °C ... 85 °C

≤ 95 % (without condensation)

IP20

ABS plastic white, similar to RAL 9010 approx. 800 g

W: 195 mm H: 140 mm D: 70 mm

1

765624

Power supply unit for automatic door release systems, 24 V, 1.5 A

As 765612, but with 24 Volt.

Technical Data

Output voltage

Output current

24 V DC max 1.5 A

10

11

12

13

14

8

9

6

7

2

3

4

5

217

Door Release System

Release Pushbuttons

1

767813.10

Triggering Devices

Surface mount release pushbutton for automatic door release system,

German

Surface mount release key for manual actuation of locking devices with double rocker switch insert.

Technical Data

Contact load

Type of protection

Housing

Color

Weight

250 V AC/10 A

IP44

ABS plastic gray, similar to RAL 7035 approx. 120 g

1

767814.10

Flush mount release pushbutton for automatic door release system,

German

Flush mount release pushbutton for manual actuation of locking devices with double rocker switch insert.

Technical Data

Contact load

Type of protection

Housing

Color

Weight

250 V AC/10 A

IP44

ABS plastic white approx. 95 g

1

796349 Label for release pushbutton

Red sticker label for release pushbutton 767813 and 767814.

10 pcs

218 www.hls-austria.com

Installation & Service

Installation Accessories

Housings

10

11

220-224

225-226

12

13

14

8

9

6

7

2

3

4

5

219

Installation & Service

Surge Protection

1

764730

1

764731

1

764732

Installation Accessories

OVP module for TTY interfaces and conventional zones

Overvoltage protection module as 4-pin, rail-mounted device.

Space-saving combined surge protector module for the protection of two wire pairs of symmetrical interfaces with electrical isolation.

Technical Data

Rated voltage

Rated current max. cont. operating voltage a.c.

max. cont. operating voltage d.c.

Nom. discharge current (80/20)/line

Total nom. discharge current

Total lightning imp. current (10/350)

Lightning imp. current (10/350)/line

Ambient temperature

Air humidity

Type of protection

24 V

1 A @ 45 °C

23.3 V AC

33 V DC

10000 A

20 kA

10 kA

2.5 kA

-40 °C ... 85 °C

< 95 % (non-condensing)

IP 20

Low resistance ground connection is a must for proper surge protection functioning.

Accessories

764737 Base for overvoltage protection module

OVP module for essernet and RS485 interfaces

Space-saving combined surge protector with LifeCheck for the protection of one wire of radio- frequency bus systems, with either direct or indirect shield grounding.

Technical Data

Rated voltage

Rated current max. cont. operating voltage a.c.

max. cont. operating voltage d.c.

Nom. discharge current (80/20)/line

Total nom. discharge current

Total lightning imp. current (10/350)

Lightning imp. current (10/350)/line

Ambient temperature

Air humidity

Type of protection

5 V

1 A @ 45 °C

4.2 V AC

6 V DC

10000 A

20 kA

9 kA

2.5 kA

-40 °C ... 85 °C

< 95 % (non-condensing)

IP 20

Accessories

764737 Base for overvoltage protection module

OVP module including base support for 230 V power supply line

Two-pin surge protector comprising base element and connected protection module, with potential- free telecommunications contact for independent fault forwarding.

Technical Data

Rated voltage max. cont. operating voltage a.c.

max. cont. operating voltage d.c.

Nominal load current a.c.

Total discharge current (8/20) [L+N-PE] 5 kA

Combined impulse

Combined impulse [L+N-PE]

Voltage protection level [L/N-PE]

Voltage protection level [L-N]

Response time [L/N-PE]

Response time [L-N]

Ambient temperature

Air humidity

Type of protection

230 V AC

255 V AC

255 V DC

25 A

6 kV

10 kV

≤ 1500 V

≤ 1250 V

≤ 100 ns

≤ 25 ns

-40 °C ... 85 °C

< 95 % (non-condensing)

IP 20

Low resistance ground connection is a must for proper surge protection functioning.

Base element and connected protection module

220 www.hls-austria.com

Installation & Service

1

764733

1

764734

1

764736

Installation Accessories

OVP module for esserbus/esserbus-PLUS loop

Space-saving combined surge protector module for the protection of two wire pairs symmetrical interfaces with electrical isolation.

Two overvoltage protection module of this type is required for each loop.

Technical Data

Rated voltage

Rated current max. cont. operating voltage a.c.

max. cont. operating voltage d.c.

Nom. discharge current (80/20)/line

Total nom. discharge current

Total lightning imp. current (10/350)

Lightning imp. current (10/350)/line

Ambient temperature

Air humidity

Type of protection

48 V

1 A @ 45 °C

38.1 V AC

54 V DC

10000 A

20 kA

10 kA

2.5 kA

-40 °C ... 85 °C

< 95 % (non-condensing)

IP 20 (connected)

Accessories

764737 Base for overvoltage protection module

OVP module

Space-saving combined surge protector module for the protection of one wire pair of symmetrical interfaces with electrical isolation.

Technical Data

Rated voltage

Rated current max. cont. operating voltage a.c.

max. cont. operating voltage d.c.

Nom. discharge current (80/20)/line

Total nom. discharge current

Total lightning imp. current (10/350)

Lightning imp. current (10/350)/line

Ambient temperature

Air humidity

Type of protection

180 V

0.75 A @ 45 °C

127 V AC

180 V DC

10000 A

20 kA

5 kA

2.5 kA

-40 °C ... 85 °C

< 95 % (non-condensing)

IP 20 (connected)

Accessories

764737 Base for overvoltage protection module

OVP module for control outputs

Power-coordinated combined surge protector for the protection of ungrounded DC power supplies for mounting-rail installation.

Protection of monitored and potential-free control outputs up to 36 volts.

Technical Data

Rated voltage

Rated current max. cont. operating voltage d.c.

Nom. discharge current (80/20)/line

Total nom. discharge current

Total lightning imp. current (10/350)

Lightning imp. current (10/350)/line

Ambient temperature

Air humidity

Type of protection

36 V

7 A @ 40 °C

45 V DC

10000 A

20 kA

5 kA

2.5 kA

-40 °C ... 85 °C

< 95 % (non-condensing)

IP 20

No base support is required for the connection.

8

9

6

7

2

3

4

5

10

11

12

13

14

221

Installation & Service

1

764737

Installation Accessories

Base module for OVP modules

Base part as very space-saving, 4-pin, universal feed-through terminal to accommodate the surge protector module without signal interruption.

The secure grounding of the surge protector module is established via the mounting rail support base by means of a snap-on attachment.

As no components of the protection circuit are located in the base part, maintenance work is restricted to the protection modules.

Technical Data

Ambient temperature

Air humidity

Type of protection

-40 °C ... 85 °C

< 95 % (non-condensing)

IP 20

Tool-free attachment on 35 mm mounting rails.

Junction Box Module

1

382040 8-fuse-card

Approval: VdS

Fuse card with 8 x 0.5 A fuses for individual power supply protection of each area, zone and component. It can be used with all ESSER mains units, fire and intrusion detection panels.

Technical Data

Contact load

Connection terminal

Ambient temperature

Storage temperature

Air humidity

Weight

Dimensions

30 V DC / 1 A

0.6 mm to max. 1.5 mm²

-5 °C ... 50 °C

-25 °C ... 75 °C

< 95 % (non-condensing) approx. 85 g

W: 65 mm H: 72 mm D: 15 mm

Possible installation in housings: Part No. 120240, 120242, 120244, 788600, 788601,

788650, 788650.10, 788651, 788651.10, 788603 and 788603.10

222 www.hls-austria.com

Installation & Service

Accessories

1

050510

Installation Accessories

Network interference suppression filter type 2VK3

The mains interference suppression filter is intended for later installation in all mains-operated devices in which problems due to HF power failure arise.

Technical Data

Rated voltage

Rated current

Rated frequency

Ambient temperature

Dimensions

115 V-250 V AC

2 A

50 ... 60 Hz

-10 °C ... 40 °C

W: 52.6 mm H: 46 mm D: 23.1 mm (without flange)

Mains interference suppression filter and terminal block

1

788602

1

788652

Top-hat rail

Technical Data

Dimensions

Mounting kit

L: 400 mm

Mounting rail for FACP

The top hat rail installation kit can be retrofitted into the IQ8Control and FlexES Control unit housing. The hat rail is fitted to the mounting board via two screws. A maximum of two (Part No.

788603.10) module housings (option) can be mounted to the control unit housing.

Technical Data

Dimensions L: 35 mm W: 175 mm (standard-snap-on mounting rail)

Mounting rail and accessories

8

9

6

7

2

3

4

5

10

11

12

13

14

Application example

223

Installation & Service

1

788603.10

Installation Accessories

Module housing for top-hat mounting rail

For snap-on mounting rail of several electronic modules with 82 x 72 mm PCB size. Angled cable entry.

Technical Data

Material

Color

1 x UM-profile and 2x side panels plastic green

1

788605

1

704147

1

704148

Application example with transponder

Mounting kit

Mounting kit required for mounting esserbus transponders in extension housings.

4 x spacer bolts and 2 x fixing screws

Cable gland M12 with nut

Polyamide cable gland to increase the protection level.

Technical Data

Ambient temperature

Type of protection

Material

Color

Cable diameter

-20 °C ... 95 °C

IP 67

Polyamide gray

3 mm

Cable gland M16 with nut

Polyamide cable gland to increase the protection level.

Technical Data

Ambient temperature

Type of protection

Material

Color

Cable diameter

-20 °C ... 95 °C

IP 67

Polyamide gray

8 mm

224 www.hls-austria.com

Installation & Service

Housings

1

788600

1

788601

Housing surface mount, gray

Small distributor housing for esserbus transponders.

The following esserbus transponder types can be used:

- 2 esserbus transponders each of dimensions (W x H x D) 82 x 72 x 20 mm

- 1 esserbus transponder of dimensions (W x H x D) 150 x 82 x 20 mm

Technical Data

Type of protection

Material

Color

Dimensions

IP 40

ABS gray, similar to RAL 7035

W: 189 mm H: 131 mm D: 47 mm

Housing flush mount, gray

Same as 788600, but flush-mounted version.

Technical Data

Type of protection

Material

Color

Dimensions

IP 40

ABS gray, similar to RAL 7035

W: 189 mm H: 131 mm D: 47 mm

W: 207 mm H: 149 mm (cover)

Housings

1

788650.10

1

788651.10

Housing surface mount, white

Same as 788600, but white.

Technical Data

Type of protection

Material

Color

Dimensions

IP 40

ABS white, similar to RAL 9003

W: 189 mm H: 131 mm D: 47 mm

Housing flush mount, white

Same as 788601, but white.

Technical Data

Type of protection

Material

Color

Dimensions

IP 40

ABS white, similar to RAL 9003

W: 189 mm H: 131 mm D: 47 mm

W: 207 mm H: 149 mm (cover)

8

9

6

7

2

3

4

5

10

11

12

13

14

225

Installation & Service

1

788655 IP55 base adapter for 788656

IP base adapter for extreme environmental conditions.

Technical Data

Type of protection IP55

1

788656

1

M200SMB

Housings

High IP housing

Housing for esserbus transponder to increase IP rating in connection with 788655.

Technical Data

Type of protection

Housing + front cover

IP55

788655 base must be ordered separatelly for IP55 protection.

Surface mounting housing for one IQ8FCT XS module

Surface enclosure for one module with semi-transparent cover to see module label, address and

LED.

Technical Data

Dimensions H: 143mm W: 130 mm D: 49 mm

1

SMB6-V0

Surface mount housing for 6 IQ8FCT XS modules

Surface enclosure for 6 modules with semi-transparent cover to see module address and LEDs.

Technical Data

Dimensions H: 180 mm W: 245 mm D: 100 mm

226 www.hls-austria.com

Appendix

Planning Guide

Order Forms

Part Number Index

Index

10

11

228

229-234

235-237

238-245

12

13

14

8

9

6

7

2

3

4

5

227

Appendix Planning Guide

Planning Guide for Loop Installation

This is a planning guide for loop-powered alarm devices.

The alarm current of each alarm device is defined as a load factor. When added up, the total load factor defines the loop length and the maximum number of alarm devices.

The maximum load factor of all alarm devices may not exceed 96. Altogether up to 127 bus devices per loop can still be connected. The "load factor" download file for easier load factor calculation is available within our customer section at http://www.esser-system.com. The examples shown below refer to a wire diameter of 0.8 mm.

The Excel spread sheet for downloading contains as well the maximum powered loop length for wires with a cross section of 1.0, 1.5, 2.5 mm².

Load factors:

Part No. Type of alarm signaling device Load factor

802382 O/So optical smoke detector IQ8Quad with isolator.................................. 2

802383 O2T/F multisensor fire detector IQ8Quad with isolator ............................. 2

802384 O2T/So multisensor fire detector IQ8Quad with isolator ........................... 2

802385 O2T/FSp multisensor fire detector IQ8Quad with isolator......................... 3

802386 O2T/Sp multisensor fire detector IQ8Quad with isolator ........................... 3

807205 IQ8Alarm/So signaler with isolator, white.................................................. 3

807206 IQ8Alarm/So signaler with isolator, red .................................................... 3

807212 IQ8Alarm/F signaler with isolator, amber flash.......................................... 3

807213 IQ8Alarm/F signaler with isolator, blue/green/white flash ......................... 3

807214 IQ8Alarm/F signaler with isolator, red flash............................................... 3

807322 IQ8Alarm/Sp signaler with isolator, white.................................................. 3

807224 IQ8Alarm/FSo signaler with isolator, red................................................... 3

807332 IQ8Alarm/Sp signaler with isolator, red ..................................................... 3

807372 IQ8Alarm/FSp signaler with isolator, red................................................... 3

Table 1.1: Maximum loop length depending on the total load factor

Total load factor

up to 800 m ................................................................................................................. 85 up to 90 up to 900 m ................................................................................................................. 79 up to 84 up to 1,000 m ............................................................................................................... 73 up to 78 up to 1,100 m ............................................................................................................... 67 up to 72 up to 1,300 m ............................................................................................................... 61 up to 66 up to 1,500 m ............................................................................................................... 55 up to 60

up to 1,700 m ............................................................................................................... 49 up to 54

up to 2,000 m ............................................................................................................... 43 up to 48

up to 2,500 m ............................................................................................................... 37 up to 42

up to 3,000 m .............................................................................................................. 31 up to 36

up to 3,500 m ............................................................................................................... 1 up to 30

Example 1:

How many IQ8Alarm alarm signaling devices with load factor 3.0 can be connected to one analog loop?

Max. total load factor 96 : 3.0 (load factor)= up to 32 pcs. IQ8Alarm devices can be connected

to each loop depending on the loop length (up to 700 m at a wire gauge 0.8 mm)

Example 2:

Various types of alarm signaling devices are connected to one loop:

Load factor

4 x 807205 alarm devices with load factor 3.0

27 x O

2

T/So multisensor fire detector IQ8Quad (802384) with load factor 2.0

= 4 x 3.0 = 12

+

= 27 x 2.0 = 54

total load factor = 66

As shown in table 1.1, the maximum loop length for a total load factor of 66 is 1,300 m (at a wire gauge 0.8 mm)

Example 3:

For alarm signaling with sounder, 25 x 802384 IQ8Quad O²T/So detectors are installed - each in one office. What is the maximum loop length?

Load factor for one 802384 IQ8Quad O²T/So detector = 2 (load factor)

25 pcs. IQ8Quad O²T/So x 2 (load factor)

total load factor = 50

As shown in table 1.1, the maximum loop length is 1,700 m (at a wire gauge 0.8 mm)

228 www.hls-austria.com

Appendix

Order Forms

Order Information for Alarm Signaling Devices IQ8Quad and IQ8Alarm composed combination of other languages and customized version

1. The IQ8Quad O²T/FSp multisensor fire detector (Part No. 802385 ) and the IQ8Alarm "Combi" Speech Alarm

(Part No. 802385) can also be ordered with a different combination of languages.

The following five languages are the programmed standard for these speech alarms. The respective languages are assigned with the five standard speech announcements for the IQ8Quad (Part No. 802385) and the IQ8Alarm

(Part No. 807372).

Country code acc. to ISO

3166 -Alpha-2

Language code acc. to ISO 639-1

Evacuation 1

Germany

(DE) de

Dies ist ein

Feueralarm. Bitte verlassen Sie das

Gebäude umgehend über die nächsten Fluchtwege. Die Feuerwehr ist alarmiert.

Great Britain

(GB) en

This is a fire alarm.

Please leave the building immediately by the nearest available exit.

France

(FR)

Spain

(ES)

Italy

(IT) fr es it

Evacuation 2

Achtung, Achtung!

Dies ist eine Gefahrenmeldung. Bitte verlassen Sie das

Gebäude über die nächsten

Ausgänge.

Attention please.

This is an emergency. Please leave the building by the nearest available exit.

An incident has been reported in the building. Please await further instructions.

Ceci est une alarme incendie,veuillez

évacuer immédiatement les locaux par la sortie la plus proche.

Votre attention s'il vous plaît, ceci est une alarme. Veuillez

évacuer les locaux par la sortie la plus proche.

Esto es una alarma de incendio.

Abandonen por favor el edificio inmediatamente por la salida de evacuación más cercana.

Attenzione.

Allarme incendio.

Abbandonare l'edificio tramite l'uscita di emergenza più vicina.

Atención. Esto es una emergencia.

Por favor abandonen el edificio por la salida de evacuación más cercana.

Attenzione.

Allarme in corso.

Vi preghiamo di recarvi presso l'uscita di emergenza più vicina.

Standard speech messages of IQ8Quad detectors and IQ8Alarm

Alarm

Achtung, im Gebäude ist eine

Gefahrensituation gemeldet worden.

Bitte bleiben Sie ruhig, und warten

Sie auf weitere

Anweisungen.

Un incident est signalé dans le batiment. Merci de garder votre calme et attendez les prochaines instructions.

Atención, se ha reportado un incidente en el edificio.

Aguarden por favor otras instrucciones.

Attenzione.

E' stato rilevato un allarme.Ulteriori disposizioni vi verranno comunicate appena possibile.

Test message All-Clear

Dies ist eine

Testdurchsage.

Die Gefahrensituation ist jetzt behoben. Wir entschuldigen uns für jegliche

Unannehmlichkeiten.

This is a test message.

No action is required.

The emergency is now cancelled. We apologize for any inconvenience.

Ceci est un test.

L'alarme est à présent annulée.

Veuillez nous excuser pour le désagrément.

Esto es un mensaje de prueba.

No se requiere ninguna acción.

La emergencia ha sido cancelada.

Pedimos disculpas por las molestias causadas.

Attenzione.

E' in corso una prova di allarme.

Non è richiesta alcuna azione.

Attenzione. Cessato allarme.La situazione di normalità è stata ripristinata.

6

7

8

3

4

5

9

10

11

12

No.

Description

1

2

Frequency

School bell

FP 1063.1 Telecoms

BS 5839 Pt1

BS 5839 Pt1

BS 5839 Pt1

BS 5839 Pt1

BS 5839 Pt1

BS 5839 Pt1

BS 5839 Pt1 complex

Alternating 800 / 970 Hz at 2 Hz

Alternating 800 / 970 Hz at 1 Hz

Intermittent 970 Hz at 1 Hz 0.5 sec.

Intermittent 2850 Hz at 1 Hz 0.5 sec.

Intermittent 970 Hz 1/4 sec. ON - 1 sec. OFF

Continuous 970 Hz

Sweep tone 800 Hz tp 970 Hz at 7 Hz

BS 5839 Pt1

DIN Tone

DIN 33404 Part 3

1200 - 500 Hz at 1 Hz

French fire sound

Sweep tone 800 Hz to 970 Hz at 1 Hz

554 Hz / 100 ms + 440 Hz / 400 ms + 10 %

NL - Slow Whoop 500 Hz - 1200 Hz at 3.5 sec. break of 0.5 sec.

13 US - Horn Continuous 485 Hz

14

15

16

17

18

19

20

US - Horn with

Temporal Pattern

US - March

Time

US - Slow

Whoop

US - Siren

US - Hi/Lo

US - NFPA

Whoop

IMO

GA-Signal

Intermittent 485 Hz

(0.5 sec. ON; 0.5 sec. OFF; 3 times; 1.5 sec. OFF; Repeat)

Alternating 485 Hz

(0.25 sec. ON; 0.25 sec. OFF; Repeat)

Sweep tone 500 Hz to 1200 Hz

(4.0 sec. ON; 0.5 sec. OFF; Repeat)

Sweep tone 600 Hz to 1200 Hz

(1.0 sec. ON, Repeat)

Alternating 100 Hz / 800 Hz

(0.25 sec. ON; Alternate; 0.25 sec. ON; Alternate; Repeat)

Sweep tone 422 Hz to 775 Hz

(upwards sweep 0.85 sec.; 3 times; 1 sec. OFF; Repeat)

Intermittent 800 Hz (1,0 sec. ON; 1,0 sec.

OFF: 7 times; 2.0 sec. ON: 2.0 sec. OFF; Repeat)

IQ8Quad detectors and IQ8Alarm tone table

Pulse rate complex f f f f f

0.25 sec.

0.25 sec.

0.5 sec.

0.5 sec.

0.5 sec.

0.5 sec.

0.5 sec.

0.5 sec.

0.25 sec.

1.0 sec.

f f f

10 ms f f

1.0 sec.

1.0 sec.

0.4 sec.

0.1 sec.

f

3.5 sec.

0.5 sec.

f f f f

0.5 sec.

0.5 sec.

0.25 sec.

0.25 sec.

4.0 sec. 0.5 sec.

1.0 sec.

f f

0.25 sec.

0.25 sec.

0.85 sec.

f f

1.0 sec.

1.0 sec.

1.5 sec.

1.5 sec.

1.5 sec.

1.0 sec.

t t t t t t t t t t t t t t t t t t t

8

9

6

7

2

3

4

5

12

13

10

11

14

229

Appendix Order Forms

Order Information: Composed Combination of Languages

Up to five languages can be provided per alarm signaling device.

Other combinations of languages can be ordered in accordance with the following order form.

The delivery time is approximately four weeks. Please note that returns or cancellations are not possible.

Order numbers for individual combination of languages

O²T/FSp multisensor fire detector IQ8Quad with isolator, composed version

IQ8Alarm/FSp signaler with isolator, red, composed version

IQ8Alarm/Sp signaler with isolator, white, composed version

IQ8Alarm/Sp signaler with isolator, red, composed version

O²T/Sp multisensor fire detector IQ8Quad with isolator, composed version

802385.SV98

807372.SV98

807322.SV98

807332.SV98

802386.SV98

802385.SV98

NL_nl

GB_en

DE_de

TR_tr

RU_ru

_____

Description:

Individual combination of languages

For example:

Phrase 1 - 5 NL_nl

Phrase 6 - 10 GB_en

Phrase 11 - 15 DE_de

Phrase 16 - 20 TR_tr

Phrase 21 - 25 RU_ru

The message type per language is always the same as mentioned in the chart

"Additional languages for individual combination”:

1 Evacuation 1

2 Evacuation 2

3 Alarm

4 Test message

5 All-Clear

Order Information: Customized Combination of Language

In case you should need customized texts differing from the standard speech messages, additional signal tones or other languages which are not listed in the order form, please contact international sales support.

Order numbers for customized programming of specific announcements/signals

O²T/FSp multisensor fire detector IQ8Quad with isolator, customized version 802385.SV99

IQ8Alarm/FSp signaler with isolator, red, customized version

IQ8Alarm/Sp signaler with isolator, white, customized version

IQ8Alarm/Sp signaler with isolator, red, customized version

O²T/Sp multisensor fire detector IQ8Quad with isolator, customized version

807372.SV99

807322.SV99

807332.SV99

802386.SV99

Description:

Customer specific announcements/signals

802385.SV99

NL_nl

GB_en

DE_de

TR_tr

RU_ru

Extra

For example:

Phrase 1 - 5 NL_nl

Phrase 6 - 10 GB_en

Phrase 11 - 15 DE_de

Phrase 16 - 20 TR_tr

Phrase 21 - 25 RU_ru

Phrase 26 - 31 Extra

(customer specific texts / special tones)

Information about delivery time and price of recording customized announcements and signals available upon request.

Please note that the maximum recording time is 169 seconds. Also please note that returns or cancellations are not possible.

The programming of speech and/or tone data is carried out at the factory according to your specifications.

The programming of the customer data is carried out via the tools 8000 programming software.

Please take a look at the relevant instructions in the online help.

230 www.hls-austria.com

Appendix

Order Forms

Additional Languages for Individual Combination Page 1

SA

Country code acc. to ISO

3166 -Alpha-2

Language code acc.

Evacuation 1 Evacuation 2 Alarm Test Message ar

- - -

Arabia

BA

Bosnia

BR

Brasil

CN

bs pt

All-Clear

Ovo je požarni alarm Molimo da odmah napustite zgradu koristeći najbliži raspoloživi izlaz.

Pažnja. Ovo je obavještenje o opasnosti.

Molimo napustite zgradu koristeći najbliži raspoloživi izlaz.

U zgradi se dogodio incident.

Molimo sačekajte dalja uputstva.

Atenção. Esta é uma emergência. Por favor, abandonem o edifício pela saída de emergência mais próxima.

Isto é um alarme de incêndio. Abandonem por favor, o edifício imediatamente pela saída de emergência mais próxima

Atenção foi reportado um incidente no edifício.

Aguardem, por favor, outras instruções.

Ovo je poruka za ispitivanje sistema.

Možete nastaviti sa vašim akltivnostimo.

Opasnost je prestala.

Izvinjavamo se radi eventualnih neugodnosti.

Esta é uma mensagem de teste.

Não se requer nenhuma ação.

A emergência foi cancelada.

Pedimos desculpas pelos problemas causados

zh

China Mandarin

DK

Denmark

Fi

Finland

GR

Greece

ES

Catalonia

HR

Croatia

NL

da fi el ca hr nl

Brandalarmen er aktiveret forlad venligst bygningen, anvend nærmeste nødudgang.

Dette er en nødsituation, forlad bygningen brug de opmærkede flugtveje.

Et varsel om brand bliver undersøgt, afvent nærmer besked.

Dette er en test melding ingen tiltag nødvendig.

Normal tilstand er genoprettet, faren er overstået.

Huomio, kiinteistössä on havaittu automaattinen paloilmoitus. Poistu rakennuksesta käyttäen ohjattuja reittejä. Hissien käyttö on kielletty.

Αυτό είναι ένα μήνυμα

συναγερμού για πυρκαγιά.

Παρακαλώ εγκαταλείψτε το

κτίριο αμέσως από τις εξόδους

κινδύνου. Η πυροσβεστική έχει δοποιηθεί.

Aixó es una alarma d´incendi.

Siusplau abandonin l´edifici inmediatament per la sortida d´evacuació més propera.

Huomio, turvallisuussyistä kiinteistöstä on poistuttava välittömästi. Käytä ohjattuja reittejä.

Προσοχή, προσοχή!

Αυτό είναι ένα μήνυμα

για κατάσταση κινδύνου.

Παρακαλώ εγκαταλείψτε

το κτίριο από τις επόμενες

εξόδους.

Atenció. Aixó es una emergencia.

Siusplau abandonin l´edifici per la sortida d´evacuació més propera.

Ovo je pozarni alarm.

Molimo odmah napustite objekt koristeci najblizi izlaz za nuzdu. Vatrogasna postaja je alarmirana.

Pozor! Pozor! Ovo je priopcenje o neposrednoj opasnosti. Molimo odmah napustite objekt koristeci najblizi izlaz za nuzdu.

Huomio, paloilmoitin on ilmoittanut mahdollisesta vaaratilanteesta.

Tutkimme asiaa ja annamme pian lisätietoja.

Προσοχή στο κτίριο υπάρχει

κατάσταση κινδύνου.

Παρακαλώ παραμείνετε

ψύχραιμοι και περιμένετε

επόμενες οδηγίες.

Atenció. S´ha notificat un incident a l´edifici.

Siusplau, esperin altres instruccions.

Pozor! U objektu je prijavljena opasnost. Molimo ostanite mirni i pricekajte daljnje upute.

Paloilmoitinjärjestelmää testataan.

Αυτή είναι μια δοκιμαστική

ανακοίνωση.

Aixó es un missatge de prova. No es requereix cap acció.

Ovo je probno priopcenje.

Nikakve mjere nisu neophodne.

Palohälytys on ohi. Tilanne on palautunut normaaliksi.

Η κατάσταση κινδύνου έχει

αρθεί. Ζητούμε συγγνώμη

για τυχόν δυσάρεστες

καταστάσεις που

προκλήθηκαν.

L´alarma ha estat cancel.lada. Preguem disculpin les molesties.

Opasnost je prestala.

Ispricavamo se radi eventualnih neugodnosti.

Attentie, er is een brandalarm.

Verlaat het gebouw via de dichtstbijzijnde uitgang.

Attentie, er is een calamiteit.

Verlaat het gebouw via de dichtstbijzijnde uitgang.

Attentie, er volgt een blussing, verlaat de ruimte.

Dit is een testalarm, dit is een testalarm.

Einde alarmmelding, einde alarmmelding.

Netherlands

NO

Brannalarmen er utløst, forlat bygget, bruk de oppmerkede rømningsveiene.

Dette -er en nødsituasjon, forlad bygget, bruk de oppmerkede rømningsveiene.

Et automatisk varsel om brann blir undersøkt, avvent nærmere beskjed.

Dette er en testmelding, ingen tiltak nødvendig.

Normaltilstand er gjenopprettet, faren er over.

Norway

no

8

9

6

7

2

3

4

5

12

13

10

11

14

231

Appendix Order Forms

Additional Languages for Individual Combination Page 2

PL

Country code acc. to ISO

3166 -Alpha-2

Language code acc.

Evacuation 1 Evacuation 2 Alarm Test Message

Poland

PT

Portugal

RO

Romania

RS

Serbia

Ru

Russia

Se

Sweden

SK

Slovakia

CZ

Czech Republic

TR

Turkey

HU

Hungary

pl pt ro sr ru sv sk cs tr hu

All-Clear

Uwaga! Wystąpił alarm pożarowy. Proszę natychmiast opuścić budynek najbliższym dostępnym wyjściem ewakuacyjnym.

Isto é um alarme de incêndio. Por favor abandonem o edifício imediatamente pela saída de evacuação mais próxima.

Atenţiune, atenţiune! S-a declanşat o alarmă de incendiu. Vă rugăm părăsiţi imediat clădirea pe cea mai apropiată cale de evacuare. Alarma a fost transmisă la pompieri.

Ovo je požarni alarm!

Molimo vas da odmah napustite zgradu koristeći najbliži raspoloživi izlaz.

Proszę o uwagę! To jest komunikat alarmowy.

Proszę opuścić budynek najbliższym dostępnym wyjściem ewakuacyjnym.

Uwaga. W budynku wystąpiło zdarzenie alarmowe. Proszę spokojnie oczekiwać dalszych instrukcji.

Atenção. Isto é uma emergência. Por favor abandonem o edifício pela saída de emergência mais próxima.

Atenção, ocorreu um incidente no edifício. Por favor aguardem mais instruções.

Atenţiune! Acesta este un mesaj de urgenţă. Vă rugăm părăsiţi clădirea pe cea mai apropiată cale de ieşire.

Pažnja! Ovo je obaveštenje o opasnosti.

Molimo vas da naupustite zgradu koristeći najbliži raspoloživi izlaz.

Atenţiune. În clădire a fost semnalat un incident. Vă rugăm să vă păstraţi calmul şi să aşteptaţi noi instrucţiuni.

U zgradi se desio incident.

Molimo vas da sečekate dalja uputsva.

Внимание. Пожарная тревога. Пожалуйста покиньте помещение через ближайшие аварийные выходы.

Внимание. Это предупреждение о пожарной опасности.

Пожалуйста покиньте помещение через ближайшие выходы.

To jest komunikat testowy.

Nie są wymagane żadne działania.

Stan alarmu został odwołany. Przepraszamy za wszelkie niedogodności i utrudnienia.

Atenção, isto é apenas um ensaio

O alarme foi cancelado.

Queiram desculpar o inconveniente.

Situaţia de urgenţă a luat sfârşit. Ne cerem scuze pentru eventualele inconveniente.

Acesta este un mesaj de test.

Ovo je poruka za ispitivanje sistema.

Možete nastaviti sa vašim aktivnostima.

Opasnost je prestala.

Izvinjavamo se zbog eventualnih neugodnosti.

Внимание. Поступило предупреждение о пожарной опасности.

Пожалуйста сохраняйте спокойствие и ждите дальнейшей информации.

Отмена пожарной тревоги. Ситуация нормализовалась.

Извините за причинённые неудобства.

Тестовое сообщение.

Идет проверка системы пожарной сигнализации.

Brandlarmet är utlöst, lämna omedelbart byggnaden genom närmaste utgång.

Detta är en nödsituation, lämna omedelbart byggnadengenom närmaste utgång.

Larm om brand i byggnaden blir undersökt, invänta närmare besked.

Detta är ett testmeddelande, ingen åtgärd är nödvändig.

Normalt tillstånd är återupprättat, faran är över.

Toto je požiarny poplach.

Opusťte prosim okamžite budovu najbližším núdzovým východom!

Pozor, hrozí nebezpečenstvo.

Opusťte prosim budovu najbližším núdzovým východom!

V budove bola vyhlásená pohotovosť. Počkajte prosim na ďalšie pokyny.

Toto je testovacie hlásenie.

Nie je potrebne naň reagovať.

Pohotovosť bola odvolaná.

Ospravedlňujeme sa za pripadne ťažkosti.

Toto je požární poplach.

Prosím, opusťte okamžitě budovu nejbližším únikovým východem.

Pozor, hrozí nebezpečí.

Prosím, opusťte budovu nejbližším únikovým východem.

V budově byla vyhlášena pohotovost. Prosím, vyčkejte dalších instrukcí.

Toto je testovací hlášení.

Není třeba na něj reagovat.

Pohotovost je nyní odvolána. Omlouváme se za případné obtíže.

Pohotovost je nyní odvolána. Omlouváme se za případné obtíže.

Acil bir durum var. Lütfen binayı en yakın çıkış noktasından terkedin.

Bu bir yangın uyarısıdır.

Bu bir yangın uyarısıdır.

Talimatlar için beklemede kalın. Talimatlar için beklemede kalın.

Yangın uyarısı test edilmektedir. Bir şey yapmanız gerekmiyor.

Bir şey yapmanız gerekmiyor.

Tűzriadó! Kérem, azonnal hagyják el az épületet az

Önökhöz legközelebb eső kijáraton!

Figyelem! Vészhelyzet!

Kérem, azonnal hagyják el az épületet az Önökhöz legközelebb eső kijáraton!

Az épületben váratlan esemény történt. További utasításig kérem várjanak!

Ez egy tesztüzenet.

Tehlike geçmiştir. Tehlike geçmiştir. Bir şey yapmanız gerekmiyor.

Vészhelyzet törölve. Az esetleges kellemetlenségekért elnézésüket kérjük.

232 www.hls-austria.com

ORDER FORM FOR IQ8 COMPOSED LANGUAGES

Honeywell Life Safety Austria GmbH Fax +43 1 600 6030-900 [email protected]

Customer

Data

Please fill out the following form for the registration of these data.

Company:

Street:

Contact Person:

Telephone:

Order Number/Order Text:

Object:

Customer ID:

Zip Code/City:

E Mail:

Fax:

Order

Combined

Version

___ 802385.SV98

___ 807372.SV98

___ 807322.SV98

___ 807332.SV98

___ 802386.SV98

Quantity______

Quantity______

Quantity______

Quantity______

Quantity______

Languages

Choose max. 5 languages

___

___

___

___

___

___

___

___

___

___

___

___

___

___

___

___

___

___

___

___

___

___

___

___

___

___

___

Arabic

Bosnian

Catalan

Chinese Mandarin

Croatian

Czech

Danish

Dutch

English

Finnish

French

German

Greek

Hungarian

Italian

Norwegian

Polish

Portuguese

Portuguese/Brazil

Romanian

Russian

Serbian

Swedish

Slovak

Slovenian

Spanish

Turkish

Country Code acc.

to Speech ISO 3166

PL

PT

BR

RO

RU

DE

GR

HU

IT

NO

RS

SE

SK

SL

ES

TR

SA

BA

ES

CN

HR

CZ

DK

NL

GB

FI

FR

Code acc. to ISO 639-1

de el hu it no da nl en fi fr ar bs ca zh hr cs sr sv sk sl es pl pt pt ro ru tr

Repeat

Orders or Additions

For repeat orders or additions please give the Order No. or the serial number of the detector with special languages.

Order Number:

Serial Number:

Date/Signature

To be filled out by Honeywell Life Safety Austria GmbH:

Please forward to Novar GmbH when filled out!

Order number:

Position:

8

9

6

7

2

3

4

5

12

13

10

11

14

233

ORDER FORM FOR IQ8 COMPOSED LANGUAGES

Honeywell Life Safety Austria GmbH Fax +43 1 600 6030-900 [email protected]

Customer

Data

Please fill out the following form for the registration of these data.

Company: Customer ID:

Street:

Contact Person:

Zip Code/City:

E Mail:

Telephone:

Order Number/Order Text:

Fax:

Order

Combined

Version

___ 802385.SV99

___ 807372.SV99

___ 807322.SV99

___ 807332.SV99

Quantity______

Quantity______

Quantity______

Quantity______

___ 802386.SV99

Technical Specifications

File with announcements/signals sent to contact person in Neuss/Germany:

Quantity______

Contact Person:

Address:

E Mail:

Sample should be approved by

(customer contact details):

Name:

Telephone:

Email:

Address:

Remark:

Take note, these standards have to be followed:

• max. length of all 5 announcements/signals is 25 seconds per file; one IQ8Quad or IQ8Alarm can record 169 seconds in total

Specifications for tone recording studio:

• WAVE or AIFF files mono with a sampling rate of 48kHz and a word width of 16-24bits

• Hi-pass: 220 Hz, 12 dB/oct.

• Lo-pass: 5 kHz, 12 dB/oct.

• Multi-band-compressor, 3-band a. 25 Hz - 350 Hz. - 5,3 dB b. 350 Hz - 5kHz. - 2,9 dB c. 5 kHz - 18 kHz. - 6,4 dB

• Brickwall-limiter

Info:

Depending on the sound quality we might have to pass it through an EQ, to make some modifications.

Additional costs for recording and/or fine tuning will be charged onetime per new file with a first order!

Second order with the same file without additional costs!

___

Repeat

Orders or

Additions

For repeat orders or additions please give the Order No. or the serial number of the detector with special languages.

Order Number:

Serial Number:

To be filled out by Honeywell Life Safety Austria GmbH:

Please forward to Novar GmbH when filled out!

Order number:

Position:

Date/Signature

234 www.hls-austria.com

Part Number Index

Part No.

Page

8100E 172

013405.20 46

013601 50

013603 50

013604 51

013605 51

013606 52

013607 52

013608 51

013609 50

013610 49

013611 52

013612 52

013613 53

013616 49

013617 49

013618 52

013624 53

013625 53

013626 50

013631 49

013635 57

013636 57

013643 50

013650 53

013652 53

013653 54

013655 54

013661 51

018001 34

018002 34

018004 34

018006 34

018007 34

018009 34

018011 34

045040 207

050510 223

060426 89

060427 90

060429 95

060431 95

382040 222

701040 104

704070 105

704147 224

Part No.

Page

704148 224

704477.10 103

704801.10 102

704804 102

704854 102

704870 102

704900 99

704901 99

704902 99

704903 99

704904 99

704910 104

704911 105

704912 105

704915 104

704917 105

704950 111

704951 111

704952 111

704953 111

704954 111

704960 115

704964 115

704965 116, 135

704966 116

704967 116, 143

704975 115

704980 112

704981 112, 134

704982 112

704983 112

736235 20

743212 20

743245 20

743248 21

744027 21

744028 21

744029 21

744030 21

761300 170

761302 170

761303 170

761304 170

761305 170

761310 171

761312 167

Part No.

Page

761314 167

761315 164

761316 164

761317 165

761317.50 165

761317.50.H 167

761317.H 166

761330 171

761331 171

761401.10 166

761402.10 166

761403 166

761404.10 168

761405.10 168

761406 168

761407 168

761440 167

761441 167

761506 181

761509 181

761514 181

761517 181

761520.10 182

761521.10 182

761522.10 182

761523.10 183

761524.10 183

761525.10 183

761526.10 184

761535 186

761536 186

761537.10 186

761542.10 184

761546.10 186

761549 184

761694 117

761697 121

764730 220

764731 220

764732 220

764733 221

764734 221

764736 221

764737 222

764744 80

764745 80

Part No.

Page

764752 81

764754 81

764790 36

765612 217

765624 217

766253 207

767010 214

767030 216

767031 216

767153 215

767800 206

767813.10 218

767814.10 218

769080 95

769910 106

769911 106

769914 20

769915 21

769916 106

769921 104

771670 19

772386 46

772387 46

772445 20

772476 18

772477 18

772478 18

772479 18

781335 32

781336 33

781337 33

781443 154

781444 155

781445 156

781446 156

781447 156

781448 156

781449 156

781482 87

781550 88

781682 106

781692 106

781693 107

781694 107

781698 107

781699 107

8

9

6

7

2

3

4

5

12

13

10

11

14

235

Part Number Index

Part No.

Page

781814 208

782302 147

782306 148

782307 148

782308 148

782310 147

782311 146

782315 146

783312 148

783313 148

784382.D0 19

784385 19

784710 38

784710.CZ 38

784710.PL 38

784725.PL 39

784743.CZ 39

784743.PL 39

784744 40

784753 40

784766 44

784840.10 43

784841.10 43

784842 19

784843 43

784855 44

784856 45

784859 45

784865 43

784892 20

785101 37

785107 37

785109 37

785113 37

786000 17

786002 16

786100 17

786102 16

786302 17

786802 17

787531 19

787532 19

788012.40 25

788013.40 25

788013.40.RU 25

788014.40 27

Part No.

Page

788014.40.CZ 27

788014.40.GB 27

788014.40.PL 27

788014.40.RO 27

788016 28

788023.10 28

788093 17

788400 28

788401 28

788402 28

788404 28

788406 28

788600 225

788601 225

788602 223

788603.10 224

788605 224

788606 46

788612 133

788650.10 225

788651.10 225

788652 223

788653 28

788654 28

788655 226

788656 226

789300 11

789301 11

789302 12

789303 15

789860.10 22

789861 22

789862.10 23

789863 23

789864 24

789866 24

796349 218

800171 61

800177 61

800271 61

800361.10 63

800371 62

800374 62

800375 62

801544.10 175

801551 187

Part No.

Page

801552 187

801553 187

801554 187

801555 187

801556 187

801557 187

801558 187

801559 187

801560 187

801561 187

801562 187

801563 187

801564 187

801565 188

801566 188

801567 188

801602 185

801604 175

801606 185

801607 185

801711 174

801722 174

801824 208

802171 65

802177 65

802271 66

802371 66

802373 66

802374 67

802375 67

802379 155

802382 73

802383 73

802384 73

802385 74

802385.SV98 74

802385.SV99 74

802386 75

802386.SV98 75

802386.SV99 75

802473 68

803271.EX 77

803371.EX 77

803374.EX 78

804382.D0 19

804473.10 103

Part No.

Page

804744 79

804791 36

804868 134

804870 133

804900 100

804901 100

804902 100

804905 101

804906 101

804920.EX 120

804950 113

804951 113

804955 114

804956 114

804960.EX 119

804961 110

804970 108

804971 109

804973 109

805550 92

805551 91

805552 92

805553 93

805560 87

805570 85

805571 83

805572.50 86

805573 86

805574 84

805576 84

805577 85

805580 89

805581 89

805582 93

805583 93

805584 93

805585 94

805586 90

805587 83

805588 83

805589 83

805590 82

805591 82

805592 63

805593.10 139

805594.10 140

236 www.hls-austria.com

Part Number Index

Part No.

Page

805595.10 141

805597 34

805601.10 142

805602.10 143

805603 143

805604 144

805605 144

805683 32

806201 206

806202 206

807205 199

807206 199

807212 204

807213 204

807214RR 205

807214WW 205

807224 202

807322 200

807322.SV98 200

807332 201

807332.SV98 201

807332.SV99 201

807372 203

807372.SV98 203

807372.SV99 203

808003 10

808004 15

808139 10

808219 15

808606 128

808610.10 129

808611.10 130

808615 130

808619.10 131

808621 127

808623 125

808623.10 126

808624 133

808626 133

808630.10 132

808631.10 132

850054 88

850055 88

950101 182

950104 182

950107 183

Part No.

Page

950110 183

950113 184

950116 183

950119 182

960000.10.GB 30

960001.10.GB 30

960002.10.GB 30

960003.10.GB 31

960004.10.GB 31

960005.10.GB 31

960006.10.GB 31

960007.10.GB 31

960008.10.GB 31

960110 216

960119 214

960120 213

960121 213

960122 213

960124 213

960126 214

960127 215

960128 215

960129 215

960130 213

970120.IN 157

970121.IN 157

970123.IN 157

970124.IN 157

970125.IN 157

970129.IN 158

970130.IN 158

970132.IN 158

970133.IN 158

970134.IN 157

970135 158

970137 159

970138 159

970139 159

970140.IN 162

970142.IN 162

970143.IN 162

970144.IN 163

970146.IN 163

970147.IN 163

970148 163

970150.IN 160

Part No.

Page

970151 160

970151.IN 160

970153.IN 160

970154 160

970154.IN 161

970161 161

970165.IN 161

970166 158

970167 158

BME2Z002 24

CWR 196

CWSO-RR-S1 190

CWSO-WW-S1 190

CWSS-RR-S3 195

CWSS-RR-S5 192

CWSS-RW-S5 192

CWSS-WA-S7 194

CWSS-WR-S3 195

CWSS-WR-S5 192

CWSS-WW-S5 192

CWST-RA-S7 193

CWST-RR-S5 191

CWST-RW-S5 191

CWST-WA-S7 193

CWST-WR-S5 191

CWST-WW-S5 191

CWW 196

DASA6-N 152

F-A3384-000 173

F-A-LC-A 173

F-A-LC-E 173

F-A-LC-G 173

F-A-LC-H 173

FL-IF-6 174

FS20X-211-23-6 150

FS20X-211-24-6 150

FS24X-911-23-6 149

FS24X-911-24-6 149

FSL100-IR3 151

FSL100-SM21 153

FSL100-TL 153

FSL100-UV 152

FSL100-UVIR 152

FSX-A001 152

M200SMB 226

PS188 196

Part No.

Page

PS189 196

PS200 122

PSU-12 153

SC070 122

SC076 196

SH-001 153

SM4

SMB6-V0

152

226

TL-1055 153

TL-2055 153

VEP-A00-1P 180

VEP-A00-P 180

VEP-A10-P 180

VEU-A00 179

VEU-A10 179

VLC-500RO 177

VLF-250 177

VLF-500 177

VLI-880 178

VLI-885 178

VLP-400 176

VLS-600 176

VSP-005 181

VSP-962 181

W1A-R1K0SG-E019-81

118

W1A-R1K0SG-U007-01

117

8

9

6

7

2

3

4

5

12

13

10

11

14

237

Index

Keyword Page

3.6 V Lithium battery

3-way ball valve (ABS)

34

185

3-way ball valve (PVC) 185

4" trim ring and snap-in mounting clips for IQ8Quad detector base

45° angle (ABS) for 25 mm pipe

45° angle (PVC) for 25 mm pipe

90° angle (ABS) for 25 mm pipe

84

183

183

182

90° angle (PVC) for 25 mm pipe

90° bend (ABS) for 25 mm pipe

90° bend (PVC) for 25 mm pipe

110/220VAC wallcharger test lamp

182

182

182

153

A

Acoustic alarm signaling device, red

Acoustic alarm signaling device, white

Adapter for pole 769813

Adapter module ADP-N3E

Adapter module ADP-PRS-422

Addressable MCP electronic module with zone isolator, Series 9200

Addressable MCP, IP66

Adhesive, 0.5 kg can with brush-in-cap

Air filter for aspirating smoke detectors

Air shield assembly 6MM

Alarm and monitoring module for IQ8FCT XS,

IQ8FCT LP

Analog loop module

Analog loop module powered loop (PL)

Anchor plate DH50-AP-S

Anchor plate DH70-AP-S

Anchor setting tool

ASD FAAST LT EB, dual channel

ASD FAAST LT EB, single channel

ASD FAAST XM

Aspiration reducing film sheet, 2.0 mm

Aspiration reducing film sheet, 2.5 mm

Aspiration reducing film sheet, 3.0 mm

Aspiration reducing film sheet, 3.2 mm

Aspiration reducing film sheet, 3.4 mm

Aspiration reducing film sheet, 3.6 mm

Aspiration reducing film sheet, 3.8 mm

Aspiration reducing film sheet, 4.0 mm

Aspiration reducing film sheet, 4.2 mm

Aspiration reducing film sheet, 4.4 mm

Aspiration reducing film sheet, 4.6 mm

Aspiration reducing film sheet, 5.0 mm

190

190

89

40

40

103

117

186

175

152

133

19

19

216

216

163

174

174

172

187

187

187

187

187

187

187

187

187

187

187

187

238 www.hls-austria.com

Keyword

Aspiration reducing film sheet, 5.2 mm

Aspiration reducing film sheet, 5.6 mm

Aspiration reducing film sheet, 6.0 mm

Aspiration reducing film sheet, 6.8 mm

Aspiration reducing film sheet, 7.0 mm

B

Base cover for IQ8Quad

Base deep IP 65, red

Base deep IP 65, white

Base module for OVP modules

Basic license for WINMAGplus USB port

Battery 12 V DC/1.2 Ah capacity

Battery 12 V DC/2.1 Ah capacity

Battery 12 V DC/7 Ah capacity

Battery 12 V DC/12 Ah capacity

Battery 12 V DC/17 Ah capacity

Battery 12V DC/24Ah capacity

Battery 12 V DC/38 Ah capacity

Battery extension housing

C

Cable gland for housing 764752

Cable gland M12 with nut

Cable gland M16 with nut

Carrying bag for test equipment

81

224

224

90

Ceiling holder for LRMX, for distances from 40 to 70 cm 168

Ceiling holder for LRMX, for distances from 70 to

150 cm 168

Ceiling lead-through adapter (ABS)

Ceiling pendant mount for Fireray

184

167

CO capsule for multi-stimulus detector tester 805551

93

Combination signaling device EN 54-23 cat. W+C, white flash 192

Combined acoustic/optical alarm device EN 54-3, open class, red flash, red housing 195

Combined acoustic/optical alarm device EN 54-3, open class, red flash, white housing 195

Combined acoustic/optical alarm device EN 54-23 cat. W+C, red flash, red housing 192

Combined acoustic/optical alarm device EN 54-23 cat. W+C, red flash, white housing 192

Combined acoustic/optical alarm device EN 54-23 cat. W+C, white flash, white housing 192

34

34

34

34

34

11

83

196

196

222

49

34

34

Page

187

187

188

188

188

Index

Keyword Page

Combined acoustic/optical alarm device, red flash, white housing 194

Condensate trap for aspirating smoke detectors 185

Connection server developers kit 52

Control center software CD WINMAGplus basic kit 49

Conventional MCP compact, small, red, glass pane

108

Conventional MCP electronic module 100, 113

Conventional MCP electronic module with 2nd microswitch 100

Conventional MCP electronic module, with 2nd micro-switch 113

Conventional MCP electronic module with 2nd microswitch, Series 9000 103

Conventional MCP electronic module w/o snap-on function 100

CO test gas for smoke detector tester 805582 93

Cutting tool for FO steel sensor cable 970153.IN 161

D

Data points package

DC/DC converter 12 V/24 V DC

DC/DC converter output voltage 12 V DC

DC/DC converter output voltage 24 V DC

Detector base with relay contact for IQ8Quad

33

82

Detector base with relay output for ES Detect

800631.10 63

52

32

33

Detector cover for IQ8Quad with built-in alarm sounder 83

Detector cover for IQ8Quad w/o built-in alarm sounder 83

Detector removal tool 89

Door magnet with distance pipe incl. flexible anchor,

400 N, 175 mm 213

Door magnet with distance pipe incl. flexible anchor,

400 N, 325 mm 213

Door magnet with distance pipe incl. flexible anchor,

400 N, 475 mm 213

Door magnet with release button incl. flexible anchor,

400 N 213

Door magnet w/o release button incl. flexible anchor,

400 N 213

Door magnet w/o release button incl. flexible anchor,

800 N 214

Door retainer DH50-N490-WM 214

Double head cable ties, 500 pcs 163

DTS evaluation unit warranty extention, 3 years 158

Keyword Page

DTS evaluation unit warranty extention, 5 years 158

DTS interface box 158

Dummy cover 19", 2 HU

Dummy cover 19", 3 HU

21

21

Dummy cover 19", 5 HU

Dummy cover 19", 9 HU

21

21

E

E2000 APC 8° pigtail, 5 m

E2000 APC adapter to connect two connectors

161

970154.IN 161

EMV isolator for IQ8Quad, ES Detect detector base

87

End cap (ABS) for 25 mm pipe 184

End cap (PVC) for 25 mm pipe

EOL-I terminating device

184

133

EOL-O terminating device 133 esserbus alarm transponder, 4 IN/2 OUT with isolator

125 esserbus communication transponder for ECP 8010

130 esserbus FSA transponder for fire doors 131 esserbus transponder 12 relays (8 bit) 129 esserbus transponder 32 LED 130 esserbus transponder for UniVario with isolator 126 esserbus transponder IQ8FCT LP 127, 128 esserbus transponder IQ8FCT XS esserbus transponder RZT, 12 V

128

132 esserbus transponder RZT, 24 V essernet® module, 62.5 kBd for IQ8Control essernet® module, 500 kBd for IQ8Control essernet repeater, 62.5 kBd

132

43

43

43 essernet repeater, 500 kBd 43

Ex barrier for intrinsic safe detectors Series IQ8Quad

Ex (i) 79

Ex barrier for intrinsic safe detectors Series IQ8Quad

Ex (i) and 9100

Ex door magnet, 1588 N

80

215

Ex manual call point IP67, small housing, red 118

Explosion-proof conventional MCP, IP66 121

Ex signaling device DS10, 12 V DC

Ex sounder, 12 V DC

207

207

Extension housing

Extension housing for batteries with 192 detector

15 zones 11

Extension housing for SZI 192 detector zones

IQ8Control 12

8

9

6

7

2

3

4

5

12

13

10

11

14

239

Index

Keyword Page

Extension module with 1 additional micromodule slot

18

Extension module with 3 additional micromodule slots 18

Extention ATEX approval for Honeywell DTS detector

158

External power supply 2 A / 24 V DC 17Ah EN 54-4

30

External power supply 3 A / 24 V DC 17Ah EN54-4 30

External power supply 3 A / 24 V DC 28Ah EN 54-4

30

External power supply 5 A / 24 V DC 17Ah EN 54-4

31

External power supply 5 A / 24 V DC 28Ah EN 54-4

31

External power supply 5 A / 24 V DC 40Ah EN 54-4

31

External power supply 7 A / 24 V DC 17Ah EN 54-4

31

External power supply 7 A / 24 V DC 28Ah EN 54-4

31

External power supply 7 A / 24 V DC 40Ah EN 54-4

31

External power supply DCU 2403 32

Extinguishing control panel 8010 Series 4 with operating unit, Czech

Extinguishing control panel 8010 Series 4 with operating unit, Polish

27

27

Extinguishing control panel 8010 Series 4 with operating unit, Romanian 27

Extinguishing control panel, Series 4, English 27

Extinguishing control panel, Series 4, German 27

Extinguishing panel 8010, Series 4, with operating unit, German 25

Extinguishing panel 8010, Series 4, with operating unit, Russian 25

Extinguishing panel 8010, Series 4, w/o operating unit 25

F

FACP IQ8Control C

FACP IQ8Control C for 19" rack

FACP IQ8Control M

FACP IQ8Control M for 19" rack

FACP remote SEI serial essernet interface 45

FB information and operating system, DIN A4, Polish

39

10

10

15

15

Keyword Page

Field bus interface PLus

Filler panel front, neutral

Filter cartridge for air duct module 781443

Fire brigade operating panel, Czech

23

17

155

38

Fire brigade operating panel, German

Fire brigade operating panel, Polish

38

38

Fire department indicating panel FAT3000, Czech 39

Fire department indicating panel FAT3000, Polish 39

Fireray 50 RV with one prism

Fireray 100 RV with four prisms

164

164

Fireray 5000 detector head 166, 167

Fireray 5000, line smoke detector, incl. controller, 50 m 165

Fireray 5000, line smoke detector, incl. controller,

100 m

Fixed heat detector ES Detect

165

61

Fixed heat detector ES Detect, Class B

Fixed heat detector IQ8Quad (class B), with higher

61 operating temperature with isolator

Fixed heat detector IQ8Quad with isolator

65

65

Flexible keeper plate for door magnets,

Ø 55 mm

216

Floor mounted bracket for door magnet 960119 and

960120 215

Flush mount kit for base IQ8Quad 83

Flush mount release pushbutton for automatic door release system, German 218

FO converter for essernet, single-mode

Foil for front face with universal text for large MCP

44

ABS, black lettering

FO sensor cable Safety FRNC

105

160

FO sensor cable Steel FRNC

Front foil with universal text for large MCP ABS,

160 white lettering

FS20X-211 IR/UV AL M25 FM/EN54

FS20X-211 IR/UV SS M25 FM/EN54

FS24X-911 3IR AL M25 FM/EN54

FS24X-911 3IR SS M25 FM/EN54

FSL100 Series Flame Detectors

FSL100 swivel mount

FSL100 test lamp, charger & case; non EX

105

150

150

149

149

151

153

153

FSX kit with Interface, RS485,USB cables 152

8-fuse-card 222

G

Ground jumper for deep base 196

240 www.hls-austria.com

Index

Keyword Page

H

I

Hardware option TCP/IP converter, Ethernet RS232 /

RS485 46

Heat detector UniVario 147

Heat detector UniVario, 2 m

Heat detector UniVario, 6 m

Heat detector UniVario, 9 m

Heat detector UniVario, 200 mm

148

148

148

147

High dense I/O interface set for Honeywell DTS detector 159

High IP housing

Honeywell DTS Detector

Housing flush mount, gray

Housing flush mount, white

Housing for Ex barrier

Housing for SEI

226

157

225

225

81

46

Housing for small MCP, blue, similar to RAL 5015 111

Housing for small MCP, green, similar to RAL 6002

111

Housing for small MCP, orange, similar to RAL 2011

111

Housing for small MCP, red, similar to RAL 3020 111

Housing for small MCP, yellow, similar to RAL 1021

111

Housing surface mount, gray

Housing surface mount, white

225

225

Indicating and operating panel for ECP 8010, Czech

28

Indicating and operating panel for ECP 8010, English

28

Indicating and operating panel for ECP 8010,

German 28

Indicating and operating panel for ECP 8010, Polish

28

Indicating and operating panel for ECP 8010, Romanian 28

Interface-Module RS232 / V24

Interface module TTY/CL 20 mA

46

46

IP43 damp room base adapter for IQ8Quad, ES

Detect detector base 86

IP43 protection for detector base IQ8Quad, deep design 86

IP43 protection for detector base IQ8Quad, flat design 85

Keyword Page

IP54 kit for large MCP 7048xx

IP55 base adapter for 788656

105

226

IP55 kit for protective cover 107

IP66 housing for OSID image sensor (imager) 171

IP66 housing for OSID standard light source (emitter)

171

IQ8Alarm/F signaler with isolator, amber flash 204

IQ8Alarm/F signaler with isolator, blue/green/white flash 204

IQ8Alarm/FSo signaler with isolator, red 202

IQ8Alarm/FSp signaler with isolator, red 203

IQ8Alarm/FSp signaler with isolator, red, composed version 203

IQ8Alarm/FSp signaler with isolator, red, customized version 203

IQ8Alarm IP 65 base, red 206

IQ8Alarm IP 65 base, white

IQ8Alarm/So signaler with isolator, red

206

199

IQ8Alarm/So signaler with isolator, white

IQ8Alarm/Sp signaler with isolator, red

199

201

IQ8Alarm/Sp signaler with isolator, red, composed version 201

IQ8Alarm/Sp signaler with isolator, red, customized version 201

IQ8Alarm/Sp signaler with isolator, white 200

IQ8Alarm/Sp signaler with isolator, white, composed version 200

IQ8MCP compact IP 66, small, red, with isolator glass pane 110

IQ8MCP compact, small, red, with isolator and glass pane 109

IQ8MCP compact, small, red, with resettable element 109

IQ8MCP electronic module 114

IQ8MCP electronic module with isolator

IQ8MCP electronic module w/o isolator, with relay

101

IQ8TAL with isolator, 1 contact IN/1 OUT

101, 114

134

IQ8Wireless cover for wireless interface, red and white 144

IQ8Wireless detector base

IQ8Wireless gateway for devices

139

140

IQ8Wireless mounting frame for IQ8Quad detectors, white 144

IQ8Wireless mounting frames for IQ8Alarm, red and white 143

8

9

6

7

2

3

4

5

12

13

10

11

14

241

Index

Keyword Page

IQ8Wireless transponder for devices, wall mount 141

IQ8Wireless universal interface w/o cover, red 142

IQ8Wireless universal interface w/o cover, white 143

IR3 flame detector RED, ATEX FM EN54 151

Isolation and assembly block for safety Ex barrier 80

K

Kit for suspended installation

L

87

Label for release pushbutton 218

Label plate for detector base IQ8Quad

Language package Estonian, Latvian, Lithuanian,

84

Russian 173

Language package German, French, Italian, Dutch

173

Language package Polish, Czech, Slovakian,

Hungarian 173

Language package Slovenian, Croatian, Romanian,

Hungarian 173

Large Conventional MCP Ex (i) IP 66/67, red with glass pane

LCD indicator panel, Czech

LCD indicator panel, English

LCD indicator panel, Hungarian

120

37

37

37

LCD indicator panel, Polish

Lever lock - type 17 for key no. 801

37

20

Lever lock - type for key no. 901 21

Line heat detector Honeywell DTS - evaluation unit, distance range 1 km 157

Line heat detector Honeywell DTS - evaluation unit, distance range 2 km 157

Line heat detector Honeywell DTS - evaluation unit, distance range 4 km 157

Line heat detector Honeywell DTS - evaluation unit, distance range 6 km 157

Line heat detector Honeywell DTS - evaluation unit, distance range 10 km

Loop isolator for transponder

157

133

Loop LED remote indicator panel for 32 messages 36

M

Management software WINMAGPlus licence for

Honeywell DTS detector

Manual call point IP67, small housing, red

51

117

Master box interface module 19

Master box interface module, 8007/8008, ESSER 19

Keyword Page

MCP housing ALU, large, glass pane

MCP housing ALU, large, neutral

102

102

MCP housing large with glass pane, blue, similar to

RAL 5015 99

MCP housing large with glass pane, green, similar to

RAL 6002 99

MCP housing large with glass pane, orange, similar to RAL 2011 99

MCP housing large with glass pane, red, similar to

RAL 3020 99

MCP housing large with glass pane, yellow, similar to

RAL 1021 99

MCP housing with glass, print: house alarm

Metal key for large MCP

102

106

Micro splice-box IP20 for Honeywell DTS sensor cables 163

Modbus TCP/IP interface for Honeywell DTS detector 158

Module housing for top-hat mounting rail

Mounting adapter for intermediate ceilings

224

85

Mounting bracket for lintel installation 206

Mounting bracket for UniVario flame detectors 148

Mounting clip for 25 mm pipe 186

Mounting frame 19" IQ8Control C/M 20

Mounting frame for small MCP, red and white 116,

143

Mounting kit 224

Mounting plate for ceiling bracket for detector/single reflector 168

Mounting rail for FACP 223

Mounting set for round and insulated air ducts 156

Mounting spider for ceiling bracket 168

Multiple-sector interface in housing

Multi-stimulus detector tester TF 1001

Multi-stimulus detector tester TF 2001

28

92

91

N

Network interference suppression filter type 2VK3

223

O

O2T/F multisensor IQ8Quad 73

O2T/FSp multisensor detector IQ8Quad, customized version 74

O2T/FSp multisensor detector IQ8Quad with composition of other languages 74

242 www.hls-austria.com

Index

Keyword Page

O2T/FSp multisensor IQ8Quad 74

O2T multisensor detector ES Detect

O2T multisensor fire detector IQ8Quad Ex (i) w/o

62 isolator 78

O2T multisensor fire detector IQ8Quad with isolator

67

O2T/So multisensor IQ8Quad

O2T/Sp multisensor IQ8Quad

73

75

O2T/Sp multisensor IQ8Quad, customized version 75

O2T/Sp multisensor IQ8Quad, special language 75

Operating foil for large MCP 80490x, neutral

Operating front, English

104

16

Operating front for printer and w. take-up reel,

English 17

Operating front with single zone indication 64,

English 16

Operating front w. printer, w/o take-up reel - ESSER,

English 17

Optical alarm signaling device, amber flash

Optical alarm signaling device, amber flash, red

193 housing 193

Optical alarm signaling device EN 54-23 cat. W+C, red flash, red housing 191

Optical alarm signaling device EN 54-23 cat. W+C, red flash, white housing 191

Optical alarm signaling device, EN 54-23 cat. W+C, white flash 191

Optical alarm signaling device, EN 54-23 cat. W+C, white flash, red housing 191

Optical alarm signaling device IQ8Alarm EN 54-23

Kat. W, red flash 205

Optical alarm signaling device IQ8Alarm EN 54-23

Kat. W, white flash 205

Optical Smoke Detector Detect ES with relay contact, 48 V DC operation

Optical smoke detector ES Detect

63

62

Optical smoke detector IQ8Quad Ex (i) w/o isolator

77

Optical smoke detector IQ8Quad with isolator 66

Option – ability for customized interface rights (clientside) 53

Optional 2nd sensor channel for Honeywell DTS detector 158

Option – client 53

Option control group indication and alarm counter for

ECP 8010, German 28

Option – escalation 53

Keyword Page

Option for 4 sensor channel for Honeywell DTS detector 158

Option IP55 shrink sleeve for large MCP 80490x 105

Option - notification 53

Option – redundance 53

O-Ring for deep base 196

OSID Emitter standard power 170

OSID Emitter standard power, battery version 170

OSID Emitter, high power

OSID Imager - 7° coverage

170

170

OSID Imager - 80° coverage

OSID installation kit

170

171

O/So optical smoke detector IQ8Quad 73

OTblue-LKM multisensor fire detector IQ8Quad with isolator 155

OTblue multisensor detector ES Detect

OTblue multisensor fire detector IQ8Quad with

62 isolator 67

OTG multisensor fire detector (CO) IQ8Quad with isolator 68

OT multisensor fire detector IQ8Quad with isolator 66

"Out of order" sign, multilingual for 7047xx, 7048xx and 70490x

OVP module

104

221

OVP module for control outputs 221

OVP module for esserbus/esserbus-PLUS loop 221

OVP module for essernet and RS485 interfaces 220

OVP module for TTY interfaces and conventional zones 220

OVP module including base support for 230 V power supply line 220

P

Peripheral module 18

Peripheral module with 1 additional micromodule slot

18

Pipe (ABS), diameter 25 mm

Pipe cutter for PVC and ABS pipes

Pipe (PVC), diameter 25 mm

Plastic key for large MCP

182

186

182

106

Plastic spare key for small MCP

Plastic telescopic extension

Plastic telescopic rod

Plate for 1 prism

Plate for 4 prism

Power supply unit for automatic door release systems, 12 V, 3 A

116

89

90

167

167

217

8

9

6

7

2

3

4

5

12

13

10

11

14

243

Index

Keyword Page

Power supply unit for automatic door release systems, 24 V, 1.5 A 217

Printer kit with paper take-up reel for IQ8Control C/M

20

Printer paper for printer 736234/784892

Programming cable for ECP 8010

Programming software tools 8000

Protective cage

20

24

22

88

Protective cover for manual call points, English 107

Protective cover for manual call points, German 107

Protective kit for MCP and TAL, transparent 116, 135

PVC detergent, 1l 186

R

19” rack mounting kit for SZI 192 detector zones 17

Rate-of-rise detector ES Detect 61

Rate-of-rise heat detector IQ8Quad Ex (i) w/o isolator 77

Rate-of-rise heat detector IQ8Quad with isolator 66

Reflector set for LRMX, for ranges of up to 80 m 166

Reflector set for LRMX, for ranges of up to 100 m 166

3-relay common fault module 19

3-relay module 19

Relay controller set for Honeywell DTS detector 159

Relays extension set for Honeywell DTS detector 159

Remote indicator esserbus-PLus for detector series

9200 and IQ8Quad, red

Remote indicator for Series 9000, 9200 and

208

IQ8Quad, red

Replacement air filter for FAAST XM

Replacement air filter pads for 801544.10

Replacement filter for 761509

Replacement integral filter for FAAST LT EB

Resettable element for small MCP

208

173

175

181

174

115

S

Seal for deep base 196

SEI serial essernet interface EDP, bidirectional 45

SEI serial essernet interface EDP, unidirectional 44

Sensor cable connectors for FO sensor cable

970150.IN 160

Sensor cable connectors for FO sensor cable

970153.IN 160

Sensor cable testing tool

Serial connecting cable for 789862.10

160

24

Service key for electronic module (Part No. 80490x)

106

Keyword Page

Single reflector for LRMX

Sleeve (ABS) for 25 mm pipe

166

183

Sleeve (PVC) for 25 mm pipe

Small Conventional MCP Ex (i) IP 66/67, red with

183 glass pane

Smoke capsule for multi-stimulus detector tester

119

805550/51 92

Smoke detector tester 93

Smoke pellets for testing purposes

Smokesabre test gas for smoke detectors

95

94

Spare battery baton 95

Spare glass pane for MCP housing 70490x, 7048xx und 761694

Spare glass pane for small MCP, EN54

104

115

Spare glass pane for small MCP, EN54, neutral 115

Spare glass pane red for MCP housings 7047xx and

7048xx 104

Spare key 1D009 for FACP 20

Spare key 801 for FACP

Spare key 901 for FACP

20

21

Spare keys pack for MCP

Special painting IQ8Quad

122

88

Special painting IQ8Quad detector base

Splice-box IP67 for Honeywell DTS sensor cables

88

163

Stainless steel anchor with plastic clamp for

Honeywell DTS cable

Standard base UniVario

162

148

Standard detector base for IQ8Quad

Standard LED remote indicator panel

82

36

Starter kit equipment PLus with programming software tools 8000 22

Steel anchor with plastic clamp for Honeywell DTS cables 162

Steel anchor with steel clamp for Honeywell DTS cables 162

Suctions hose set for 25 mm pipe

Sun shield SS SS2/SS4/FS24X

184

153

Surface mount housing for 6

IQ8FCT XS module

226

Surface mount housing for small MCP and TAL, blue, similar to RAL 5015 134

Surface mount housing for small MCP, blue, similar to RAL 5015 112

Surface mount housing for small MCP, gray, similar to RAL 7035

Surface mount housing for small MCP, orange,

112 similar to RAL 2011 112

244 www.hls-austria.com

Index

Keyword Page

Surface mount housing for small MCP, red, similar to

RAL 3020 112

Surface mount housing for small MCP, yellow, similar to RAL 1021 112

Surface moun. housing for 1

IQ8FCT XS module 226

Surface mount release pushbutton for automatic door release system, German

Surface spacer for protective cover

218

107

Switched-mode power supply with cylindrical plug 24

Swivel mount 152

SZI front for 192 detector zones 17

T

Terminal card for panel 8010 in 19" rack, 1 m

Terminal card for panel 8010 in 19" rack, 2 m

Test gas for smoke detector tester 805582

Test head for heat detector w.battery and charger 95

Test lamp FS18X/FS20X/FS24X EXP 153

Test lamp FS18X/FS20X/FS24X NON-EXP 153

Three-channel infrared flame detector UniVario 146

Top-hat rail 223

T-Piece (ABS) for 25 mm pipe 183

T-Piece (PVC) for 25 mm pipe

Transparent cover for MCP

183

122

28

28

93

U

Univ. bracket for F5000 or prism plate

761440/761441 167

USB cable A/B for 789862.10 field bus and panel interface 23

UV flame detector RED, ATEX FM EN54

UV flame detector UniVario

UVIR flame detector RED, ATEX FM EN54

UVIR flame detector RED, ATEX FM EN54

152

146

152

152

V

Venturi air duct module for IQ8Quad OTblue-LKM

(802379) 154

Venturi tube for IQ8Quad air duct construction set

781443, 0.6 m 156

Venturi tube for IQ8Quad air duct construction set

781443, 1.5 m 156

Venturi tube for IQ8Quad air duct construction set

781443, 2.8 m

VESDA 300 PC interface

VESDA filter for VEU, VEP

VESDA filter for VLP, VLS, VLF, VLC

VESDAnet™ connection box

156

181

181

181

181

Keyword Page

VESDA VEP 1 pipe with LEDs

VESDA VEP 4 pipe with display

VESDA VEP 4 pipe with LEDs

VESDA VEU with Display

VESDA VEU with LEDs

VESDA VLC

VESDA VLF-250

VESDA VLF-500

VESDA VLI Relay only

VESDA VLI with VesdaNet

VESDA VLP

VESDA VLS

W

Wall and floor swivel bracket for door magnet 960119 and 960120, angled, 150 mm 215

Wall and floor swivel bracket for door magnet 960119 and 960120, angled, 300 mm 215

110/220VAC wallcharger test lamp 153

Wall mounted door magnet w/o release button, 490

N 214

Wall mount housing IP66 for Honeywell DTS 157

Weather protection housing for air duct construction set 781443 156

Weather protective cover for MCP housings

7047/48xx, blue

Weather protective cover for MCP housings

7047/48xx, red

106

106

WINMAG installation upgrade as of version 6 49

WINMAGLite upgrade to WINMAGplus full version 57

WINMAGLite with USB dongle

WINMAGplus – 4-monitor support option

57

54

WINMAGplus – AutoCAD option 54

WINMAGplus control center software - subsequent upgrade 50

WINMAGplus license - access control 50

WINMAGplus license connection server 52

WINMAGplus license - fire detection technology 50

WINMAGplus license - Galaxy Dimension 50

WINMAGplus license - intrusion detection technology 50

WINMAGplus license – OPC client 52

WINMAGplus license – OPC server

WINMAGplus license - rescue route technology/

52 escape door control

WINMAGplus license - RTD

WINMAGplus license - video technology

WINMAG upgrade to WINMAGplus

51

51

51

49

180

180

180

179

179

177

177

177

178

178

176

176

245

2

3

4

5

6

7

8

9

10

11

12

13

14

Honeywell Life Safety Austria GmbH

Technologiestrasse 5, Building F, 3rd floor

1120 Vienna, Austria

Phone: +43 1 600 6030

Fax: +43 1 600 6030-900 www.hls-austria.com [email protected]

Part No. 054581.AT.G0

June 2017

Subject to change without notice

©2017 Honeywell International Inc.

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project