Fire Alarm Systems - hls
Product catalog EE
Valid from June 2017
Fire Alarm Systems
Contents
1
2
3
4
5
6
7
8
9
General Hints
3-5
General Information
3-5
Control Panels
7-28
IQ8Control
Extingishing System
8-24
25-28
Power Supplies
29-34
Power Supply Units
Voltage Converters
Batteries (Rechargeable)
Accessories
30-32
33
34
34
Displays and Operating Units
35-40
LED Indicator Panel
LCD Indicator Panel
System 3000
36
37
38-40
Network Technology
41-46
essernet
42-46
Hazard Management System
47-58
WINMAGplus
WINMAGLite
Difference WINMAGLite vs WINMAGplus
48-56
57
58
Automatic Detectors
59-95
Series ES Detect (Conventional)
Series IQ8Quad (Intelligent Addressable)
Intrinsically Safe
Base Series IQ8Quad, ES Detect
Accessories
60-63
64-75
76-81
82
83-95
Manual Call Points
97-122
Large Design (ABS)
Large Design (Aluminum)
Accessories for MCP large design
Small Design (ABS)
Accessories for MCP small design
Special Design
98-101
102-103
104-107
108-114
115-116
117-122
Transponders / Input & Output Modules
123-135
esserbus
124-135
Wireless Components
137-144
Wireless Modules
138-144
1
Contents
10
11
12
13
14
2
www.hls-austria.com
Detectors for Special Applications
145-188
Flame and Heat Detectors
Air Duct Detectors
Linear Heat Detectors
Linear Smoke Detectors
Aspirating Smoke Detectors
146-153
154-156
157-163
164-171
172-188
Alarm Devices
189-208
Conventional ENscape
Intelligent Addressable IQ8Alarm
Intrinsically Safe
Remote Indicators
190-196
197-206
207
208
Door Release System
209-218
Automatic Door Systems
Door Holding Devices
Triggering Devices
210-212
213-217
218
Installation & Service
219-226
Installation Accessories
Housings
220-224
225-226
Appendix
227-245
Planning Guide
Order Forms
Part Number Index
Index
228
229-234
235-237
238-245
General Hints
General Information
Contact us
Headquarters
Honeywell Life Safety Austria GmbH
Technologiestrasse 5, building F, 3rd floor
1120 Vienna, Austria
Phone:+43 1 600 60 30
E-mail: hls-austria@honeywell.com
Internet: www.hls-austria.com
Czech Republic / Slovakia
Honeywell, spol. s r.o.
V Parku 2325/16
148 00 Prague 4 - Chodov, Czech Republic
Phone: +420 242 442 280
E-mail: hls-czech@honeywell.com
Internet: www.hls-czech.com
Poland
Honeywell Sp.z.o.o.
Budynek Nefryt, Domaniewska 39
02-674 Warsaw, Poland
Phone: +48 22 313 09 70
E-mail: hls-poland@honeywell.com
Internet: www.hls-poland.com
Romania
Honeywell Life Safety Romania S.R.L.
Upground - BOC Office Building
Str. George Constrantinescu nr. 3, building A, 4th floor
District 2, 020338 Bucharest, Romania
Phone: +40 31 224 36 10
E-mail: hls-romania@honeywell.com
Internet: www.hls-romania.com
Honeywell Life Safety Romania S.R.L.
Salcâmilor str. 2 bis
305500 Lugoj, Romania
Phone: +40 256 35 00 00
E-mail: hls-romania@honeywell.com
Internet: www.hls-romania.com
Russia
Honeywell ZAO
8th floor, Kievskaya str., 7
121059 Moscow, Russia
Phone: +7 495 7969 800
E-mail: hls-russia@honeywell.com
Internet: www.hls-russia.com
Ukraine
FE Honeywell Ukraine
Office Center „IRVA“, Block A
Radyscheva str. 10/14
03680 Kiev, Ukraine
Phone: +380 44 351 15 50
E-mail: hls-ukraine@honeywell.com
Internet: www.hls-russia.com
3
General Hints
General Information
Abbreviations
The list below provides a brief explanation of various abbreviations used in this product guide.
ABIGA
=
Acc.
=
Approx. =
ATEX
=
BOSEC =
BTS
=
CNBOP =
4
integrated operating unit for
alarm systems
according to
approximately
EU directive for explosive
atmosphere
I/O
IP
IR
=
=
=
input / output
ingress protection rating
infrared
LAN
LCD
LED
LF
LKM
LPCB
LRS
=
=
=
=
=
=
=
local area network
liquid crystal display
light emitting diode
low frequency
air duct detector
Loss Prevention Certification Board
high sensitivity aspiration detector
MCP
MFAB
MM
=
=
=
manual call point
master box
micromodule
NC
NO
=
=
normally closed
normally opened
OTG
=
optical, heat and gas
extinguishing control panel
ESSER data protocol
electromagnetic compatibility
European Norm
end of line
enhanced signaling protocol for
alarm processes
explosion proof / intrinsically safe
PCB
pcs.
PL
PLC
PM
PTB
=
=
=
=
=
=
PU
=
printed circuit board
pieces
powered loop
programmable logic control
delay and verify functions
national institute of natural
and engineering sciences
packaging unit
ROR
=
rate-of-rise heat detector
SEI
SHV
SMD
SL
SOC
SZI
=
=
=
=
=
=
serial essernet interface
smoke heat ventilation module
surface mounted technology
silent
switch-on control
single zone indicator
TAL
TM
=
=
technical alarm module
coincidence detection
USB
UV
=
=
universal serial bus
ultraviolet
VDE
=
VdS
=
VGA
VPP
=
=
association for electrical, electronic
and information technologies
association of German property
insurance companies
video graphics array
voltage peak-peak
Belgian institute for the approval
of fire alarm-related products
base transceiver station
Polish research and development
center for fire protection
DIBt
=
German institute for technical
approvals
dual in line
German institute for
standardization
dual in parallel
DIL
DIN
=
=
DIP
=
ECP
EDP
EMV
EN
EOL
ESPA
=
=
=
=
=
=
Ex
=
FACP
FAS
FB
FBF
FBOIU
=
=
=
=
=
FCT
=
FD
FDS
FIBS
FO
FSA
=
=
=
=
=
fire alarm control panel
fire alarm system
fire brigade
fire brigade panel
fire brigade operating and
indicating unit
fire control transponder
(input/output module)
fire detection
fire detection system
fire brigade operating system
fiber optic
door release system
GI
=
galvanic isolated
HMI
HU
=
=
human machine interface
used for 19” rack, 1 HU = 44.45 mm
www.hls-austria.com
General Hints
General Information
S ymbols used
=
List of contents which the pa rt number includes
=
Packing unit
=
Information, important notice
such as special versions, dependencies etc.
=
Available starting on
IP typ e of protection
The type of protection indicates the suitability of electric operating materials (for examp le, devices, lights and installation material)
agai nst solid foreign objects and for various ambient conditions.
Levels of protection from contact and foreign bodies (first digit)
Digit
Protection from contact
Pr otection from foreign bodies
0
No protection
No protection
1
Protec tion from large-size d body parts
(diameter 50 mm)
Large foreign bodies
(diameter from 50 mm)
2
Finger protec tion
(diameter 12 mm)
Medium-size foreign bodies
(diameter from 12.5 mm)
3
Tools and wires
(diameter from 2.5 mm )
Small foreign matter
(diameter from 2.5 mm)
4
Tools and wires
(diameter from 1 mm)
Granular foreign matter
(diameter from 1 mm)
5 (K )
Wire protection (as IP 4) dust-protec ted
Dust acc umulation
6 (K )
Wire protection (as IP 4) dust-proof
No ingress of dust
Levels of protection from water (second digit)
Dig it
Pr otec tion from water
0
No protection
1
Protection from vertically dripping water
2
Protection from diag onally (15°) falling drip water
3
Protection from falling spray water up to 60°, against the vertica l
4
Protection agains t splashing water
5
Protection from hose water (nozzle) from any angle
6
Protection from strong hose water (flooding)
7
Protection from temporary submersion
8
Protection from permanent submersion
Example:
IP64: Completely dust-proof – protected against splashing water – nearly leak-proof.
5
Notes
6
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
11
Control Panels
IQ8Control
Extinguishing System
8-24 12
25-28
13
14
7
IQ8Control Panels
IQ8Control C/Intelligent Addressable
IQ8Control C/Intelligent Addressable
Features
• Max. two micromodules (system supports up to ​
254 digital loop addresses in total)
• Max. two esserbus analog loop modules
• Short circuit and open circuit resistant loop oper­
ation
• Loop installation with I-Y(ST)Y 0.8 mm cable for ​
a maximum length of 3.5 km
• Up to 127 esserbus devices (fire detectors and/​
or manual call points)/detector zones per loop
• Up to 32 esserbus transponders/wireless transponders per loop
• Up to 127 IQ8/FCT transponders per loop
• Operation types TM and PM as per DIN VDE ​
0833 - 2 to avoid unwanted alarms being ​triggered
• Fire brigade operating panel and alarm trans­
mission unit interface on the peripheral module
• Three common relays, freely programmable, ​
monitored, floating for up to 24 V DC/1A (on the ​
peripheral module)
• TTY or RS 485 interface, optional RS 232
• Integration in the short circuit and open circuit ​
resistant essernet network with up to 31 fire ​
detection panels depends on transmission rate
• Connection to graphical supervisor WINMAG via
serial essernet interface ​(SEI)
• Operating panel with alphanumerical display
• Large LCD display with 8 rows x 40 characters
• Event memory for up to 10,000 events
• All System 8000 micromodules are compatible
• Printer interface for internal printer
• Two batteries with monitoring circuit
• Monitored input for external power supply unit
Additional features for powered loop
• Max. 2 analog powered loop modules (System ​
supports up to 254 digital loop addresses in ​
total)
• BUS powered, synchronously controlled, ​
acoustic alarm signaling devices as per DIN EN ​
54-3 with alarm tone as per DIN 33404
• Up to 48 powered loop base sounders (series ​
9200) per loop
• Up to 32 powered loop IQ8Alarm per loop
• Up to 48 IQ8Quad with alarm device per loop
Approval: VdS, CNBOP, BOSEC
VdS system certificate: S 294050
The IQ8Control C is an efficient fire alarm control panel for the property supervision of small to ​
mid-sized objects facilitates simultaneous detection, control and alarm signaling both on the analog ​
ring as well as on the spur.
Within the multi-functional IQ8Control C panel, the operation type (powered-loop or non-powered-​
loop) can be selected via a jumper located on the control panel power supply unit.
Depending on which loop operation type has been selected, the corresponding loop module/​
modules are required.
Technical Data
Rated voltage
Rated frequency
Rated current
Quiescent current
Current consumption for ext. devices
Battery capacity
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
Declaration of Performance
230 V AC
50 ... 60 Hz
0.35 A (standard); 0.7 A (powered loop)
approx. 215 mA (basic configuration without ​operating unit)
approx. 230 mA (basic configuration with operating ​
unit)
max. 2 A @ 12 V DC
2 x 12 Ah, 2 x 26 Ah in extension housing
-5 °C ... 45 °C
-5 °C ... 50 °C
< 95 % (non-condensing)
IP30
ABS, 10 % glass fiber reinforced, V - 0
gray similar to Pantone 538
approx. 6.5 kg
W: 450 mm H: 320 mm D: 185 mm
DoP-20827130701
- The IQ8Control fire detection panels are fully compatible with FACP 8000 panels within ​
essernet applications
- FACP 8000 micromodules are also compatible with IQ8Control devices
- Housing form and color comply with the FACP 8000 generation
- The IQ8Control panels can only be programmed with the tools 8000 software solution (Part ​
No. 789861) and the field bus interface (Part No. 789862.10) or directly via USB with the RS-​
232 interface (Part No. 769828), with the field bus interface or the RS232 interface.
Combined with Part No. 808619.10 FSA transponder, the control panel can be used to ​
control automatic door arrester systems in compliance with the German Institute for ​Construction Engineering (DIBt: Deutsches Institut für Bautechnik).
external equipment
12V DC
Fiber optic converter
essernet
Loop length max. 1 km
esserbus-PLus
Loop length max. 3.5 km
(with repeater max. 3 km)
IQ8Control C
IQ8Control C
Repeater
esserbus transponder
Management System
XS Guard
Connection example
8
www.hls-austria.com
IQ8Control Panels
IQ8Control C/Intelligent Addressable
1
Order Diagram FACP IQ8Control C/Intelligent Addressable
2
1.
Choice of the
housing type
3
IQ8ControlC standard housing 808003
4
IQ8ControlC for 19” cabinet 808139
Slot for one micromodule as standard
2.
Choice of the
control panel
modules
(only 1 module at a time)
5
772478
Extension module with
one additional micromodule slot
772479
Peripheral module
772477
Peripheral module with
one additional micromodule slot
6
7
3.
Choice of the
micromodules
4.
Choice
of the
operating front*
804382.D0
784382.D0
Analog loop module powered loop Analog loop module
771670
Master box interface
module
784840.10
essernet module 62.5kBd
787531
3-relay module
784385
Master box interface
module
784841.10
essernet module 500kBd
784842
RS 232/TTY
serial interface module
787532
3-relay
common fault module
8
9
787530
4-relay module
10
language codes available:
01 Germany
02 England
03 Italy
04 Portugal
05 Poland
06 Spain
07 Austria
08 Netherlands
09 Czech Republic
10 Russia
11 Hungary
12 Denmark
13 Sweden
14 Croatia
15 France
16 Slovakia
17 Switzerland / French
18 Romania
19 Slovenia
20 Turkey
21 Greece
22 Belgium / Flemish
23 Belgium / Walloon
25 Arabic / English
27 Serbian
11
7860_ _
Operating front
7861_ _
Operating front w.
SZI f. 64 detector
zones
7868_ _
786000
7863_ _
Operating front with Operating front for SZI front for 192
printer,
detector zones
printer,
w/o take-up reel* w. take-up reel**
786100
Filler panel front,
neutral for
IQ8Control C/M
12
13
788093
19” rack mounting kit for
SZI 192 detector zones
14
All operating fronts, except SZI 192 detector zones are suitable for both housing types
*Space for only 1 battery **Requires an additional extension housing
5.
Choice of a
extension housing
(optional)
789300
Battery extension housing
789302
Extension housing for SZI
192 detector zones
789301
Extension housing for batteries and
SZI 192 detector zones
9
IQ8Control Panels
IQ8Control C/Intelligent Addressable
FACP IQ8Control C Standard and for 19" Racks
808003
FACP IQ8Control C
1
Basic design.
The operating front must be ordered separately and is not included in the price.
Housing with standard rear panel and front frame for operating panel fronts, interface board, power ​
supply module, system software.
808139
FACP IQ8Control C for 19" rack
1
Same as 808003, but 19" version (7 HU) for rack installation.
The operating front must be ordered separately and is not included in the price.
FACP 808003 IQ8Control C, including 19" installation frame and flat cable for 19" installation.
10
www.hls-austria.com
IQ8Control Panels
IQ8Control C/Intelligent Addressable
Accessories for FACP IQ8Control C
1
789300
Battery extension housing
2
1
Extension housing for additional batteries.
Technical Data
Ambient temperature
Storage temperature
Type of protection
Housing
Weight
Dimensions
3
-5 °C ... 45 °C
-10 °C ... 50 °C
IP 30
ABS, 10% glass fiber reinforced, V - 0
approx. 5 kg (without battery)
W: 450 mm H: 320 mm D: 185 mm
4
Batteries are not included and must be ordered separately.
5
Housing complete with battery rear panel, connecting cable for battery, mounting positions for two 12 V/​
26 Ah batteries. Neutral front and material for attaching to the existing panel housing, battery connecting ​
cables, 800 mm.
6
Assembling the housing parts
Take off the
4 standard covers.
Insert the
2 connecting elements.
Put the 2 housings
on top of each other
and push them together.
7
8
9
10
1.
2.
3.
11
Connection between the central housing and the extension housing
789301
12
Extension housing for batteries with 192 detector zones
1
Technical Data
Quiescent current
Current consumption
Ambient temperature
Type of protection
Housing
Color
Weight
Dimensions
approx. 5 mA
1.5 mA when LED activated
-5 °C ... 45 °C
IP 30
ABS, 10% glass fiber reinforced, V - 0
gray similar to Pantone 538
approx. 5.5 kg (without battery)
W: 450 mm H: 320 mm D: 185 mm
13
14
This housing cannot be used if an operating module front with single zone indicator unit for ​
64 zones is already fitted. Batteries are not included and must be ordered separately.
A single zone indicator unit can only be used in connection with an operating module front.
Housing complete with battery rear panel, connecting cable for batteries, mounting positions for two 12 ​V
/ 26 Ah batteries, single zone indicator front for 192 detector zones and material for attaching to the ​existing panel housing.
11
IQ8Control Panels
IQ8Control C/Intelligent Addressable
789302
Extension housing for SZI 192 detector zones IQ8Control
1
The housing can be used to mount additional modules, e.g. an esserbus transponder.
Technical Data
Quiescent current
Current consumption
Ambient temperature
Type of protection
Housing
Color
Weight
Dimensions
approx. 5 mA
1.5 mA when LED activated
-5 °C ... 45 °C
IP 30
ABS, 10% glass fiber reinforced, V - 0
gray similar to Pantone 538
approx. 5 kg
W: 450 mm H: 320 mm D: 185 mm
This housing cannot be used if an operating module front with single zone indicator unit for ​
64 zones is already fitted. A SZI unit can only be used in combination with an operating ​
module front.
Housing complete with standard rear panel, single zone indicator front for 192 detector zones and ​material for attaching to the existing panel housing.
12
www.hls-austria.com
IQ8Control Panels
IQ8Control M/Intelligent Addressable
1
IQ8Control M/Intelligent Addressable
Features
• Max. five micromodules, with peripheral module ​
Part No. 772477, up to five esserbus analog ​
loop modules (system supports up to 635 digital ​
loop addresses in total)
• Max. seven micromodules, with extension ​
module Part No. 772476, up to seven esserbus ​
analog loop modules (system supports up to ​
889 digital loop addresses in total)
• Short circuit and open circuit tolerant loop oper­
ation
• Loop installation with I-Y(ST)Y 0.8 mm cable for ​
a maximum length of 3.5 km
• Up to 127 esserbus devices (fire detectors and/​
or manual call points)/detector zones per loop
• Up to 32 esserbus transponders/wireless transponders per loop
• Up to 127 IQ8/FCT transponders per loop
• Operation types TM and PM as per DIN VDE ​
0833 - 2 to avoid unwanted alarms being ​triggered
• Fire brigade operating panel and transmission ​
interface on the peripheral module
• Three common relays, freely programmable, ​
monitored, floating for up to 30 V DC/1A (on the ​
peripheral module)
• TTY or RS 485 or RS 232 interface
• Integration in the short circuit and open circuit ​
resistant essernet network with up to 31 fire ​
detection panels depends on transmission rate
• Connection to graphical supervisor WINMAG via ​
serial essernet interface (SEI)
• Operating panel with alphanumerical display
• Large LCD display with 8 rows x 40 characters
• Event memory for up to 10,000 events
• All Systems 8000 micromodules are compatible
• Printer interface for internal printer
• Two batteries with monitoring circuit
• Monitored input for external power supply unit
Additional features for powered loop
• Max. 6 analog powered loops and expandable ​
up to 127 loop devices (per loop) in mixed mode ​
/ loop powered and non-loop powered (system ​
supports up to 762 digital loop addresses in ​
total)
• esserbus PLus (Powered Loop) supplied, ​
synchronously controlled, acoustic alarm ​signaling devices as per DIN EN 54 - 3 with ​alarm
tone as per DIN 33404
• Up to 48 powered loop base sounders (series ​
9200) per loop
• Up to 32 powered loop IQ8Alarm per loop
• Up to 48 IQ8Quad with alarm device per loop
Approval: VdS, CNBOP, BOSEC
VdS system certificate: S 294050
2
The IQ8Control M as an efficient fire alarm control panel (FACP) for the property supervision of ​
mid-sized to large objects, facilitates simultaneous detection, control and alarm signaling both on ​
the analog ring as well as on the spur.
The loop operation type of the panel (powered-loop or non-powered-loop) can be selected via a ​
jumper located on the power supply card.
Depending on which loop operation type has been selected, the corresponding analog module/​
modules should be used.
Technical Data
Rated voltage
Rated frequency
Rated current
Output voltage
Quiescent current
Current consumption for ext. devices
Battery capacity
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
Declaration of Performance
3
4
230 V AC
50 ... 60 Hz
0.35 A (standard); 0.7 A (powered loop)
12 V DC
approx. 215 mA (basic configuration without ​operating unit)
approx. 230 mA (basic configuration with operating ​
unit)
max. 2 A @ 12 V DC
max. 2 x 12 V/26 Ah
-5 °C ... 45 °C
-10 °C ... 50 °C
< 95 % (non-condensing)
IP30
ABS, 10 % glass fiber reinforced, V - 0
gray similar to Pantone 538
approx. 11.5 kg
W: 450 mm H: 640 mm D: 185 mm
DoP-20827130701
5
6
7
8
9
- The IQ8Control fire detection panels are fully compatible with FACP 8000 panels within ​
essernet applications
- FACP 8000 micromodules are also compatible with IQ8Control devices
- Housing form and color comply with the FACP 8000 generation
- The IQ8Control panels can only be programmed with the tools 8000 software solution (Part ​
No. 789861) and the field bus interface (Part No. 789862.10) or directly via USB with the RS-​
232 interface (Part No. 769828), with the field bus interface or the RS232 interface.
10
11
Combined with 808619.10 FSA transponders, the control panel can be used to control ​automatic door arrester systems in compliance with the German Institute for Construction ​
Engineering (DIBt: Deutsches Institut für Bautechnik).
12
13
14
Network segment lenght max. 1 km
Application example
13
IQ8Control Panels
IQ8Control M/Intelligent Addressable
Order Diagram FACP IQ8Control M/Intelligent Addressable
1.
Choice of the
housing type
Wall housing
808004
IQ8Control M for 19" cabinet
808219
Slot for one micromodule as standard
2.
Choice of the
control panel
modules
2 Extension modules
or
1 Extension module
+
1 Peripheral module
772478
Extension module
with one additional
micromodule slot
772476
Extension module with
three additional
micromodule slots
772479
Peripheral module
804382.D0
784382.D0
Analog loop module powered loop Analog loop module
3.
Choice of the
micromodules
4.
Choice
of the
operating front*
784842
RS 232/TTY
Serial interface module
787531
3-relay module
787532
3-relay
common fault module
772477
Peripheral module
with one additional
micromodule slot
771670
Master box interface
module
784840.10
essernet module 62,5kBd
784385
Master box interface
module
784841.10
essernet module 500kBd
787530
4-relay module
language codes available:
01 Germany
02 England
03 Italy
04 Portugal
05 Poland
06 Spain
07 Austria
08 Netherlands
09 Czech Republic
10 Russia
11 Hungary
12 Denmark
13 Sweden
14 Croatia
15 France
16 Slovakia
17 Switzerland / French
18 Romania
19 Slovenia
20 Turkey
21 Greece
22 Belgium / Flemish
23 belgium / Walloon
25 Arabic / English
27 Serbian
7860xx
Operating front
7868xx
7861xx
Operating front w. Operating front
SZI f. 64 detector with printer
zones
7863xx
786000
Operating front for SZI front for 192
printer,
detector zones
w. take-up reel*
788093
19” rack mounting kit for
SZI 192 detector zones
All operating fronts, except SZI 192 detector zones are suitable for both housing types
*Requires an additional extension housing
5.
Choice of a
extension housing
(optional)
789303
Extension housing f. additional modules
14
www.hls-austria.com
786100
Filler panel front,
neutral
IQ8Control Panels
IQ8Control M/Intelligent Addressable
FACP IQ8Control M Standard and for 19" Racks
1
808004
FACP IQ8Control M
2
1
Basic design.
The operating front must be ordered separately and is not included in the price.
3
Housing with rear panel and front frame for operating panel fronts, neutral front, interface board, power ​
supply module and system software.
4
5
808219
FACP IQ8Control M for 19" rack
1
As 808004 but 19" version (7 HU) for rack installation.
6
The operating front must be ordered separately and is not included in the price.
FACP IQ8Control M 808004, including 19" mounting frame and flat cable for 19" installation.
7
8
789303
Extension housing
1
Features
• For the installation of up to 6 transponders
and FO ​converters with installation kit
788650.
The standard extension housing can be used to mount additional modules, e.g.
esserbus ​transponders.
9
Technical Data
Ambient temperature
Storage temperature
Type of protection
Housing
10
-5 °C ... 45 °C
-10 °C ... 50 °C
IP30
ABS plastic, 10% glass fiber reinforced, V 0
gray similar to Pantone 538
approx. 5 kg
W: 450 mm H: 320 mm D: 185 mm
Color
Weight
Dimensions
11
12
Housing complete with standard rear panel, neutral front and material for attaching to
the ​existing control panel housing.
13
Assembling the housing parts
Take off the
4 standard covers.
1.
Insert the
2 connecting elements.
2.
Put the 2 housings
on top of each other
and push them together.
14
3.
Connection between the central housing and the extension housing
15
IQ8Control Panels
Accessories
Operating Fronts for IQ8Control C/M
Features
• alphanumerical display
• Large LCD display with 8 rows x 40 characters ​
786002
ESSER - front (Part No. 7860XX, 7861XX, 7863XX, 7864XX, 7865XX, 7868XX and 7869XX) is
also ​available with the respective country specification - except the special versions. When ordering, ​please fill in the last two digits with the specific language code.
(Not all variants are available in all languages. Please contact your sales representative for details)
Example:
The German version of the standard operating front C/M would have the Part No. 7860-01.
For the Dutch version, the number would have to be changed to Part No. 7860-08.
Specific language code:
01 German
14 Croatian
02 English
15 French (France)
03 Italian
16 Slovakian
04 Portuguese
17 French (Switzerland)
05 Polish
18 Romanian
06 Spanish
19 Slovenian
07 German (Austria)
20 Turkish
08 Dutch
21 Greek
09 Czech
22 Flemish (Belgium/Dutch)
10 Russian
23 Walloon (Belgium/French)
11 Hungarian
25 Arabic/English
12 Danish
27 Serbian
13 Swedish
52 Chinese
13 Swedish
53 Chinese with country functionality
Operating front, English
1
786102
Operating front with single zone indication 64, English
1
Technical Data
Current consumption
16
www.hls-austria.com
single zone indication: per activated LED
1.5mA
IQ8Control Panels
786802
Accessories
Operating front w. printer, w/o take-up reel - ESSER, English
1
Technical Data
Quiescent current
2
1
approx. 45 mA
Possible alternative is operating front 7863xx, printer 784892 and housing extension 789303
3
772445 Mounting frame
786000 SZI front for 192 detector zones, including insertable foils with country-specific version
4
Features
• integrated printer w/o paper take-up reel
5
786302
Operating front for printer and w. take-up reel, English
6
1
The printer kit with paper take-up reel (Part No. 784892) must be ordered separately.
7
8
9
786000
SZI front for 192 detector zones
10
1
Technical Data
Quiescent current
Current consumption
approx. 5 mA
single zone indication: per actuated LED 1.5mA
11
Including insertable foils with country-specific version.
12
786100
13
Filler panel front, neutral
1
14
788093
1
19” rack mounting kit for SZI 192 detector zones
7 HU for upright cabinet mounting.
Technical Data
Quiescent current
Current consumption
approx. 5 mA
1.5 mA per actuated LED
772445 Mounting frame
786000 SZI front for 192 detector zones, including insertable foils with country-specific version
17
IQ8Control Panels
Accessories
Control Panel Modules for IQ8Control C/M
772479
Peripheral module
1
The peripheral module contains a fire brigade operating panel interface as well as an alarm trans­
mission unit interface and three freely programmable, optionally monitored or up to 30 V DC ​floating common relays. The peripheral module can only be used on system terminal 1 of the ​control
panel interface board.
Technical Data
Quiescent current
approx. 15 mA
Only one (Part No. 772477/78/79) module can be plugged onto the interface board.
772477
Peripheral module with 1 additional micromodule slot
1
Same as 772479 but with one additional micromodule slot. The peripheral module can only be ​
used on system terminal 1 of the control panel interface board.
Technical Data
Quiescent current
approx. 15 mA (without micromodule)
Only one (Part No. 772477/78/79) module can be plugged onto the basic module.
772478
Extension module with 1 additional micromodule slot
1
The extension module is plugged onto the interface board of the control panel. The extension ​
module can only be used on system terminal 1 of the control panel interface board.
Technical Data
Quiescent current
approx. 5 mA (without micromodule)
Only one (Part No. 772477/78/79) module can be plugged onto the interface board.
772476
Extension module with 3 additional micromodule slots
1
The extension module is plugged onto the interface board of the control panel. This extension ​
module can be used on plug connectors 1 and 2 of the basic control panel module.
Technical Data
Quiescent current
approx. 5 mA (without micromodule)
The (Part No. 772476) extension module can only be used in the IQ8Control FACP.
18
www.hls-austria.com
IQ8Control Panels
Accessories
1
Micromodules for IQ8Control C/M
2
784382.D0
Analog loop module
1
Single loop circuit module for up to 127 series 9200/IQ8 Quad intelligent fire detectors or bus ​
devices, divisible into 127 zones.
Technical Data
Quiescent current
3
approx. 25 mA
4
804382.D0
Analog loop module powered loop (PL)
1
Single loop circuit module for up to 127 bus devices, and esserbus-PLus (powered loop) devices ​
according to the load factor. Series 9200/IQ8 Quad intelligent fire detectors and esserbus ​transponders (Part No. 80xxxx) or addressable sounders and powered loop base sounders.
5
Technical Data
Quiescent current
6
approx. 25 mA
Powered loop compatible only with IQ8Control and FlexES.
7
784385
Master box interface module
1
Single master box interface module for activating and processing acknowledgement signals from ​
master boxes; programmable as constant or pulsed master box activation.
Technical Data
Quiescent current
771670
1
8
approx. 15 mA
9
Master box interface module
Single master box interface module for activating and processing acknowledgement ​signals from
master boxes; programmable as constant or pulsed master box activation, for ​potential-free triggering.
10
11
784842
Master box interface module, 8007/8008, ESSER
1
Serial interface module with optional RS 232 or TTY type, for operating external devices such as ​
external printers, printers, modems for remote diagnosis.
Technical Data
Quiescent current
approx. 35 mA (RS 232)
approx. 55 mA (TTY)
3-relay module
1
3-relay module with output functions which can be programmed either as NC or NO contacts, 3 x ​
latching "monitored" relay outputs.
approx. 5 mA
max. 30 V DC/1 A
787532
3-relay common fault module
1
3-relay module with pre-set functions such as common fault, 2 x freely programmable monitored ​
relay outputs.
Technical Data
Quiescent current
Contact load relay
13
14
787531
Technical Data
Quiescent current
Contact load relay
12
approx. 15 mA
max. 30 V DC/1 A
19
IQ8Control Panels
Accessories
Accessories
784892
Printer kit with paper take-up reel for IQ8Control C/M
1
40 characters, printer with fixed print head.
When the printer is installed in the FACP IQ8Control C, the battery case, including toroidal ​transformer,
must be replaced by the mounting rack. The batteries and the toroidal transformer ​must be installed in an
additional extension housing, either 789300 or 789301.
Mounting frame complete with Part No. 736234 plain text thermal printer including winder and ​end-ofpaper recognition.
Accessories
736235 Printer paper for printer 736234 / 784892
736235
Printer paper for printer 736234/784892
1
Printer paper part no. ​736234 printer with take-up reel.
Technical Data
Dimensions
772445
L: 2500 mm W: 58 mm
Mounting frame 19" IQ8Control C/M
1
Mounting frame with 6 HU for mounting of operating front.
743212
Spare key 1D009 for FACP
1
For upright cabinets 769163 and 769164.
Two keys.
743245
Lever lock - type 17 for key no. 801
1
To lock and unlock the HMI of fire alarm panels 2001, IQ8Control C/M, 8000
M/C, 8007, ​8008.
Two keys and one cylinder lock.
769914
Spare key 801 for FACP
1
To lock and unlock the HMI of fire alarm panels 2001, IQ8Control C/M, 8000
M/C, 8007, ​8008.
Two keys.
20
www.hls-austria.com
IQ8Control Panels
743248
Accessories
1
Lever lock - type for key no. 901
1
To lock and unlock the housing frame of fire alarm panels IQ8Control C/M, 8000
M/C and ​FlexES.
2
Two keys and one cylinder lock.
3
769915
4
Spare key 901 for FACP
1
For fire alarm panels 2001, IQ8Control C/M, 8000 C/M, 8008 for printer and
housing.
5
Two keys.
6
7
744030
Dummy cover 19", 2 HU
1
For covering free installation space in upright cabinets and wallmount cabinets, 2 HU.
Technical Data
Material
Color
8
sheet steel
gray similar to Pantone 538
9
One height unit (HU) covers 44.45 mm.
10
744027
Dummy cover 19", 3 HU
1
Same as 744030, but 3 HU.
Technical Data
Color
11
gray similar to Pantone 538
12
13
744028
Dummy cover 19", 5 HU
1
Same as 744030, but 5 HU.
744029
Dummy cover 19", 9 HU
1
Same as 744030, but 9 HU.
14
21
IQ8Control Panels
Accessories
Maintenance and Test Equipment
789861
Programming software tools 8000
1
Convenient Windows programming software CD for programming the fire alarm panels belonging ​
to series 8000 C/M, 8008, IQ8Control, FlexES Control, Gateway and extended supplementary text ​
in ¼ VGA display.
Available Languages:
Czech, Danish, English, French, German, Hungarian, Italian, Slovakian, Spanish, Polish, ​Portuguese, Romanian and Russian.
Features
One software for all panels:
• Start-up
• Programming
• Loop diagnosis
• Maintenance software
For programming, the (Part No. 789862.10) field bus interface is required.
- FACP 8000 C/M, FACP 8008, IQ8Control C/M, FlexES Control or ECP 8010 as of software ​
version V2.20
- PC/Notebook as of Windows XP, Windows 7, Windows 8
- Recommended configuration: 512 MB RAM, 500 MHz CPU
- This software is also used for the LCD panels 7851xx
789860.10
Starter kit equipment PLus with programming software tools 8000
1
Complete package for programming the FACP 8007, 8000 C/M, 8008, Gateway, ABIGA IQ8Control ​
and FlexES Control via PC or Notebook.
The field bus interface is used as a programming interface between the FACP and the PC/​
notebook.
Furthermore, the field bus interface facilitates the direct connection of a ring bus to the ​
convenient monitoring of a finished installation and the elimination of possible cabling ​
mistakes.
789861
789862.10
789863
789864
Programming software for System 8000 and IQ8Control
Field bus and control panel interface PLus
USB cable
Serial connecting cable
Accessories
BME2Z002 Switched-mode power supply with cylindrical plug
789866
Programming cable for extinguishing panel 8010
Control panel
USB
Field bus interface
esserbus PLus
Loop length max. 3.5 km
esserbus transponder
Application example
22
www.hls-austria.com
IQ8Control Panels
Accessories
789862.10
Field bus interface PLus
1
1
Interface for the programming of the FACP 8007, 8000 C/M, 8008, gateway, ABIGA and IQ8Con­trol
or for the direct field-side connection of a single installed analog loop. With the optional ​switched-mode power supply (Part No. BME2Z002), bus-supplied alarm signaling equipment can ​be
tested independently from the control panel via the direct connection to the field bus interface ​(Part
No. 789862.10).
2
3
Technical Data
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
5 °C ... 45 °C
0 °C ... 50 °C
IP 40
plastic, PS (Polystyrene)
white, similar to RAL 9010 / gray, similar to RAL 7035
approx. 300 g
W: 68 mm H: 30 mm D: 135 mm
4
5
Connecting cables (Part No. 789863 and 789864) are not included in delivery.
One interface and two 6-pin plugs.
6
Accessories
BME2Z002 Switched-mode power supply with cylindrical plug
7
8
USB
Power supply for bus supplied
alarm signaling devices
9
Field bus interface
EFI-Plus
10
esserbus-PLus
Loop length max. 3,5 km
11
esserbus-transponder
12
Application example
789863
USB cable A/B for 789862.10 field bus and panel interface
1
For connecting service PC/laptop with the tools 8000 field bus and panel interface.
Technical Data
Cable length
13
14
1.8 m
23
IQ8Control Panels
Accessories
789864
Serial connecting cable for 789862.10
1
For connecting the field bus interface to panels 8007, 8000 C/M, 8008, Gateway, ABIGA and ​
IQ8Control. With 4-pin special plug for the control panel.
Technical Data
Cable length
BME2Z002
1.9 m
Switched-mode power supply with cylindrical plug
1
Technical Data
Output voltage
Output current
12 V DC
1A
789866
Programming cable for ECP 8010
1
Connecting lead for programming the extinguishing control panel 8010 to 789862.10 interface.
Fieldbus interface
USB
Connecting cable, Part No. 789866
esserbus
Extinguishing panel 8010
24
www.hls-austria.com
Control Panels
Extinguishing System
1
Extinguishing System 8010 - Wall Mounting
1
Approval: VdS
Features
• 1 Extinguishing area for max. 1.600 m² acc.
•
•
•
•
•
•
•
•
•
•
•
•
to ​VdS
8 detector zones for up to 30 Series 9200
and ​IQ8Quad automatic detectors each (for
two-​detector dependency up to 25 detectors)
1 zone for manual alarm
1 zone for emergency stop
1 zone for post flooding
1 zone for extinguishing system fault
1 zone for blocking extinguishing system
1 control input for buzzer OFF
1 control input for control panel reset
8 relays, monitored or floating 30V DC/2A
3 relays, floating 30V DC/2A
2 mains voltage relays, floating 230V AC/2A
All outputs are provided with fuses
2
Addressable control device with integrated fire detection module for an extinguishing area ​in accordance with VdS 2496 and EN 12094-1. The extinguishing
panel 8010 is an elec­tronic control device for extinguishing systems with integrated fire detection module, ​compatible with Series 9200 and IQ8Quad detectors.
It is additionally provided with ​respective detection zones for manual alarm, post
flooding and emergency stop as well as ​two zones for extinguishing system fault.
Complex control functions can be realised by ​using the 13 control groups
(relays). Up to 8 extinguishing areas on the esserbus of the ​fire detection system
communication transponders (optional). Respectively max. 16 ​communication
transponders per FACP 8000 C/M or IQ8Control 8000 or IQ8Control can be ​
networked via the 808615.
Technical Data
Rated voltage
Rated frequency
Quiescent current
Rated current
Battery capacity
Ambient temperature
Storage temperature
Type of protection
Housing
Color
3
4
5
230 V AC
50 ... 60 Hz
approx. 100 mA
0.7 A
2 x 12 V/26 Ah
-5 °C ... 45 °C
-10 °C ... 50 °C
IP 30
sheet steel approx. 1.25 mm
gray (similar to RAL 7035), blue (similar to
RAL 5003)
approx. 18.3 kg (without battery)
W: 488 mm H: 625 mm D: 210 mm
0786-CPD-20223
Weight
Dimensions
CE certificate
6
7
8
9
The free programming software can be downloaded from our website (downloads
section).
Accessories
10
Indicating and operating unit 788400 (required for stand alone operation), 788615 esserbus ​
communication transponder, control zone indicator and 788016 alarm counter.
11
esserbus
Loop length max. 3.5 km
12
Extinguishing
panel 8010
IQ8Control
Monitoring
Module
Extinguishing Agent
Tank
Valve
13
Selector
Valve
Application example
788012.40
1
Corresponding indication and operating panel available in different languages, which can be found ​
in "Options for Extinguishing Control Panels 8010 Wall Mounting".
788013.40
Extinguishing panel 8010, Series 4, with operating unit, German
1
Same as 788012.40, but with operating unit (Part No. 788400).
788013.40.RU
1
14
Extinguishing panel 8010, Series 4, w/o operating unit
Extinguishing panel 8010, Series 4, with operating unit, Russian
Same as 788013.40, but Russian version.
25
Control Panels
Extinguishing System
Extinguishing Control Panel 8010 - Rack Mounting, 3HU
Features
• 8 detector zones for up to 30 series 9200 or ​
IQ8Quad automatic fire detectors per detector ​
zone (max. 25 detectors in two-detector ​dependency)
• 1 detector zone manual alarm
• 1 detector zone emergency stop
• 1 detector zone post flooding
• 1 detector zone blocked extinguishing system
• 1 control input buzzer off
• 1 control input reset control panel
• 8 monitorable relays 30 V DC /2A
• 3 floating relays 30 V DC /2A
• 2 relays for mains voltage 230 V (connection at ​
the back)
• Each output is protected by fuses
• Electronically controlled ventilation fan
Operating unit:
• 13 LED-indication with inscription fields for indic­
ating activated outputs
• Mechanical alarm counter
• LED display to indicate the detector zone status
• LED collective display
• Keypad can be intuitively handled
• Key operated switch for keypad activation
• Emergency current supply 2 batteries 12 V/12 ​
Ah (not supplied as standard)
Addressable EN 12094-1 extinguishing panel for extinguishing zone control in compliance with ​
VdS 2496, with integrated fire detection unit and optional convenient operating and indicating ​
panel.
The slide-in concept enables space-saving, ergonomic integration into a 19" housing for installation​
heights of only 3 height units (13.34 cm). Peripherals are connected at the back of the housing via ​
plug-in cable connections to accessible connection terminals, allowing convenient installation ​
within the housing before the insert is integrated. With the communication transponder (Part No. ​
808615), a maximum of eight extinguishing control panels can be networked on one esserbus or ​
powered loop in fire alarm systems FACP 8000, Q8Control or FlexES Control. Using the programming interface ​plugged to the front, the extinguishing panel settings can be adjusted to the specific
requirements ​and information can be transferred for visualizing the master fire alarm system via
the loop.
Technical Data
Rated voltage
Rated frequency
Rated current
Quiescent current
Battery capacity
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Dimensions
Declaration of Performance
230 V AC
50 ... 60 Hz
0.7 A
approx. 100 mA
2 x 12 V DC/12 Ah
-5 °C ... 45 °C
-10 °C ... 50 °C
< 95 % (non-condensing)
IP 30
sheet steel
W: 483 mm H: 132 mm D: 403 mm (without grip)
DoP-20223130701
The use of heavy duty rails from the respective cabinet manufacturer is recommended for ​
installation in 19" upright cabinets.
Special
Connection module
incl. connection cable
(Part No. 788653
or 788654)
Fire alarm and
extinguishing
panel
No.1 to No.5
Power supply 230 V
Installation of multiple extinguishing panels in one upright cabinet
26
www.hls-austria.com
Control Panels
788014.40
Extinguishing System
1
Extinguishing control panel, Series 4, German
1
Approval: VdS
Extinguishing panel as per 12094 for extinguishing zone control in complaince with VdS 2496, with ​
integrated fire detection unit and optional convenient operating and indicating panel. The slide-in ​
concept enables space-saving, ergonomic integration into a 19-inch housing for installation heights ​
of only 3 height units (13.35 cm). Peripherals are connected at the back of the housing via plug-in ​
cable connections to accessible connection terminals, allowing convenient installation within the ​
housing before the insert is integrated. With the communication transponder (Part No. 808615), a ​
maximum of eight extinguishing control panels can be networked on one esserbus or powered ​
loop in Fire Alarm Systems FACP 8000, IQ8Control or FlexES Control. Via the programming interface plugged to ​the front, the extinguishing panel settings can be adjusted to the specific requirements and inform­ation can be transferred for visulaising to the master fire alarm system via the
loop.
2
3
4
5
Accessories
788653 Terminal card for panel 8010 in 19" technology (3 HU), 1 m
788654 Terminal card for panel 8010 in 19" technology (3 HU), 2 m
6
788014.40.GB
Extinguishing control panel, Series 4, English
1
Same as 788014.40, but English version.
788014.40.PL
7
Extinguishing control panel 8010 Series 4 with operating unit, P
​ olish
8
As.40, but Polish version.
788014.40.CZ
Extinguishing control panel 8010 Series 4 with operating unit, C
​ zech
9
As 788014.40, but Czech version.
788014.40.RO
10
Extinguishing control panel 8010 Series 4 with operating unit, R
​ omanian
As 788014.40, but Romanian version.
11
12
13
14
27
Control Panels
Extinguishing System
Accessories for Extinguishing Control Panels 8010 in 19" Racks
788653
Terminal card for panel 8010 in 19" rack, 1 m
1
Length of plug-in connection cables: 1 m
2 x 50-pin connection cable 1m D-Sub50
1 x Terminal card for top hat rail or C-rail mounting with D-Sub pin connectors
1 x Terminal card for top hat rail or C-rail mounting with D-Sub multi-point connectors
788654
Terminal card for panel 8010 in 19" rack, 2 m
As 788653, but plug-in connection cable with 2 m length.
788400
Indicating and operating panel for ECP 8010, German
Integrated detector zone indication in German. Can be set to show status indication for control
outputs. ​LED for relevant extinguishing system function indication.
788401
Indicating and operating panel for ECP 8010, English
Same as 788400, but English.
788402
Indicating and operating panel for ECP 8010, Polish
As 788400, but Polish.
788404
Indicating and operating panel for ECP 8010, Czech
As 788400 but Czech.
788406
Indicating and operating panel for ECP 8010, Romanian
As 788400 but Romanian.
788016
Option control group indication and alarm counter for ECP 8010, ​German
Additional LEDs for indicating activated control outputs and mechanical alarm counter. The indic­
ators are mounted to the second recess of the 8010 releasing control equipment. The PCB ​
connection cable is connected to the (Part No. 788400) indicating and operating panel.
1
Foil with German description
788023.10
Multiple-sector interface in housing
1
Approval: VdS
For the formation of multiple-sector control, up to four extinguishing panels 8010 can be networked ​
via a multiple-sector interfaces. The cascading of a max. of 3 multiple-sector interface is possible ​
for multi-sector control of a max. of 10 extinguishing panels 8010.
Technical Data
Declaration of Performance
28
www.hls-austria.com
DoP-21170130701
1
2
3
4
5
6
7
8
9
10
11
Power Supplies
Power Supply Units
30-32
Voltage Converters
33
Batteries (Rechargeable)
34
Accessories
34
12
13
14
29
Power Supplies
Power Supply Units
Power Supply - Housing Version
1
Approval: VdS, CNBOP
The power supply ZSP135-DR is dedicated to work in fire detection and building automa­tion
systems. It is a source of guaranteed 24V voltage. It is manufactured as a wall box ​with a lock. It
has a space inside to mount two batteries. The controller protects the ​internal battery bank against
too low discharge by means of the built-in disconnect device. ​The power supply complies with the
norm EN 54 and EN 12101-10.
Features
• light indication of the state of the power supply
• floating mode with temperature compensation
• equalize charging of the battery with the charging ​
•
•
•
•
•
•
•
current limitation
detection of low and high voltage of the battery
detection of a battery circuit break
electronic low voltage disconnect of the battery
monitoring of output fuses
continuous testing of the rectifier’s operation
monitoring of the internal temperature
visual and remote indication of alarm
960000.10.GB
Application:- components of fire alarm systems
- actuators of smoke extraction systems and fire and smoke dampers
- fire alarm detector and sounders
- devices of industrial automation
Technical Data
Rated voltage
Output voltage
Efficiency
Cooling
Ambient temperature
Type of protection
230 V AC
24 V DC
> 80 %
Convection
-25 °C ... 55 °C
IP43
External power supply 2 A / 24 V DC 17Ah EN 54-4
Batteries for power supplies ZSP135-DR should be ordered separately.
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
960001.10.GB
max.2 A
1 A
max. 17 Ah
approx. 18 kg (incl. batteries)
W: 390 mm H: 350 mm D: 90 mm
External power supply 3 A / 24 V DC 17Ah EN54-4
Batteries for power supplies ZSP135-DR should be ordered separately.
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
960002.10.GB
max.3 A
2 A
max. 17 Ah
approx. 18 kg (incl. batteries)
W: 390 mm H: 350 mm D: 90 mm
External power supply 3 A / 24 V DC 28Ah EN 54-4
Batteries for power supplies ZSP135-DR should be ordered separately.
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
30
www.hls-austria.com
max.3 A
1.5 A
max. 28 Ah
approx. 28.3 kg (incl. batteries)
W: 390 mm H: 350 mm D: 140 mm
Power Supplies
960003.10.GB
Power Supply Units
1
External power supply 5 A / 24 V DC 17Ah EN 54-4
Batteries for power supplies ZSP135-DR should be ordered separately.
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
960004.10.GB
2
max.5 A
4 A
max. 17 Ah
approx. 18 kg (incl. batteries)
W: 390 mm H: 350 mm D: 90 mm
3
External power supply 5 A / 24 V DC 28Ah EN 54-4
4
Batteries for power supplies ZSP135-DR should be ordered separately.
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
960005.10.GB
5
max.5 A
3.5 A
max. 28 Ah
approx. 28.3 kg (incl. batteries)
W: 390 mm H: 350 mm D: 140 mm
6
External power supply 5 A / 24 V DC 40Ah EN 54-4
7
Batteries for power supplies ZSP135-DR should be ordered separately.
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
960006.10.GB
max.5 A
3 A
max. 40 Ah
approx. 42.3 kg (incl. batteries)
W: 450 mm H: 350 mm D: 180 mm
8
9
External power supply 7 A / 24 V DC 28Ah EN 54-4
10
Batteries for power supplies ZSP135-DR should be ordered separately.
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
960007.10.GB
max.7 A
5.5 A
max. 28 Ah
approx. 28.3 kg (incl. batteries)
W: 390 mm H: 350 mm D: 140 mm
11
12
External power supply 7 A / 24 V DC 40Ah EN 54-4
Batteries for power supplies ZSP135-DR should be ordered separately.
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
960008.10.GB
13
max.7 A
5 A
max. 40 Ah
approx. 42.3 kg (incl. batteries)
W: 450 mm H: 350 mm D: 180 mm
14
External power supply 7 A / 24 V DC 17Ah EN 54-4
Batteries for power supplies ZSP135-DR should be ordered separately.
Technical Data
Output current
Rated Output Current
Battery capacity
Weight
Dimensions
max.7 A
5 A
max. 17Ah
approx. 42.3 kg (incl. batteries)
W: 450 mm H: 350 mm D: 180 mm
31
Power Supplies
Power Supply Units
External power supply DCU 2403
Approval: G 210052
External power supply in a compact metal housing for up to two 12 V/ 24 Ah batteries. This power
supply facilitates an uninterruptable supply of power. Integration into the esserbus/esserbus-Plus
optional via optional adapter card (Part No. 805684.10) and esserbus Transponder (Part No.
808623). Four floating relay outputs are available for the transmission of disturbances (power
failure, ground fault, battery failure and collective fault). External LED display for operation and
collective fault on the lockable front door, internal LEDs for detailed recognition of emergency
power operation, individual monitoring of battery failure and ground fault.
Features
• Reversible output voltage 12 V DC or 24 V DC
• Simple integration into esserbus/esserbus-Plus
• Internal service LED displays
• Four floating relay outputs
• Monitoring of mains voltage with selectable
delay time
• Individual battery monitoring for emergency
power operation
• Switchable ground fault monitoring
• Front door with cover contact
• in compliance with EN 54-4/A2
• for use in voice alarms to supply recessed
components, such as at fiber optic recessed
callstations
Technical Data
Rated voltage
Rated frequency
Output voltage
Battery capacity
Output current
Contact load relay
Ambient temperature
Storage temperature
Connection terminal
Housing
Type of protection
Air humidity
Color
Weight
Dimensions
230 V AC
50 ... 60 Hz
12 V DC / 24 V DC; ± 1 % (temperature controlled)
max. 48 Ah @ 12 V DC / max. 24 Ah @ 24 V DC
6 A @ 12 V DC / 3 A @ 24 V DC
max. 125 V / 1,5 A / 60 VA
-5 °C ... 40 °C
-20 °C ... 45 °C
max. 2,5 mm²
sheet steel
IP 30
< 95 % (non condensing)
gray, similar to RAL 7035
approx. 23 kg incl. batteries each 12 V DC / 24 Ah
W: 310 mm H: 410 mm D: 211 mm
Batteries used in the power supply must be tested and VdS approved. Batteries of the same
age from the same manufacturer coming from the same production batch must be used when
connecting batteries in parallel.
Pre-installed connector cable for 12 V / 24 Ah SB-type battery (Part No. 018006)
Housing lock with key
Device accessory kit contains: dummy cover, jumper bar for standby terminal, device fuses, jumper for
setup of output voltage
Accessories
805684.10 Adapter card for DCU 2402
808623 esserbus alarm transponder
781335
DC/DC converter 12 V/24 V DC
1
Approval: VdS
This converter generates 24 V as power supply for special detectors. The input voltage of 12 V is ​
taken from the FACP or an external 12 V power supply. Mounted inside the FACP (mounting kit ​
Part No. 788605), this module can supply up to 4 special detectors with a maximum current of 125 ​
mA each or 1 special detector with 500 mA. This module can be integrated in cabinets (Part No. ​
120240, 788600 and 788601). Please pay attention to the primary current consumption (12 V) in ​
case of mains failure.
Features
• Each output is separately fused
32
www.hls-austria.com
Technical Data
Operating voltage
Output voltage
Output current
Ambient temperature
Storage temperature
Air humidity
Type of protection
Weight
Dimensions
Declaration of Performance
9 ... 15 V DC
24 V DC ± 10 %
max. 500 mA (4 x 125 mA)
-10 °C ... 50 °C
-15 °C ... 55 °C
< 95 % (non-condensing)
IP 40 (housing)
approx. 150 g
W: 65 mm H: 72 mm D: 20 mm
DoP-20616130701
Power Supplies
781336
Voltage Converters
1
DC/DC converter output voltage 12 V DC
1
Approval: VdS
2
This converter generates 12 V as "electrically isolated" power supply for one special detector. The ​
input voltage of 12 V is taken from the FACP or an external power supply. This module can be ​integrated in cabinets (Part No. 120240, 788600, 788601 and 788603.10). Please pay attention to ​the
primary current consumption (12 V) in case of mains failure.
Features
• Direct current potentials are electrically isolated
• Voltage interface, for instance, for operating ​
transponders connected to an extinguishing ​
control panel 8010 Series 3 configured for 12 V ​
DC operation
• Suitable for max 1.5 mm² connection terminals
• Short circuit resilient
Technical Data
Operating voltage
Output voltage
Output current
Ambient temperature
Storage temperature
Air humidity
Type of protection
Weight
Dimensions
Declaration of Performance
3
4
10 ... 28 V DC
12 V DC ± 10 %
max. 800 mA
-10 °C ... 50 °C
-15 °C ... 55 °C
< 95 % (non-condensing)
IP 40 (housing)
approx. 70 g
W: 65 mm H: 72 mm D: 20 mm
DoP-20617130701
5
6
The module can also be used in explosion endangered zones for the galvanic separation of ​
the esserbus voltage supply.
781337
7
DC/DC converter output voltage 24 V DC
8
1
Approval: VdS
This converter generates 24 V as power supply for one special detector. The input voltage of 12 V ​
is taken from the FACP or an external power supply. This module can be integrated in cabinets ​
(Part No. 120240, 788600, 788601 and 788603.10). Please pay attention to the primary current ​
consumption (12 V) in case of mains failure.
Features
• Direct current potentials are electrically isolated
• Suitable for max 1.5 mm² connection terminals
• Short circuit resilient
Technical Data
Operating voltage
Output voltage
Output current
Ambient temperature
Storage temperature
Air humidity
Type of protection
Weight
Dimensions
Declaration of Performance
9
10
10 ... 28 V DC
24 V DC ± 10 %
max. 400 mA
-10 °C ... 50 °C
-15 °C ... 55 °C
< 95 % (non-condensing)
IP 40 (housing)
approx. 70 g
W: 65 mm H: 72 mm D: 20 mm
DoP-20617130701
11
12
13
14
33
Power Supplies
Power Supply - Accessories
The listed lead storage battery are maintenance-free, sealed electrolyte batteries. They are relat­
ively position-independent (should not be charged upside-down), deep-cycled, cycle-resistant and ​
long-lasting (4 to 5 years). Charge voltage at an ambient temperature of +20°C: 12 V DC (6 x 2.3 ​
V per cell) 13.8 volts, this can be subject to tolerances.
Technical data sheets are available on demand.
The batteries comply with the VDE 0833-1 regulations for hazard alarm systems and are VdS ​
approved.
018001
Battery 12 V DC/1.2 Ah capacity
018002
Battery 12 V DC/2.1 Ah capacity
018004
Battery 12 V DC/7 Ah capacity
018011
Battery 12 V DC/12 Ah capacity
2 x Fast-on adapters from 6.3 mm to 4.3 mm
018006
Battery 12V DC/24Ah capacity
2x Fast-On Adapter from M6 by 6.3mm each 2x M5 hex bolt/washers and snap ring
018007
Battery 12 V DC/17 Ah capacity
2 x Fast-on adapters from M6 to 6.3mm each 2 x M5 hexagon head cap screws, washers and snap ​
rings.
018009
Battery 12 V DC/38 Ah capacity
2 x Fast-on adapters from M6 to 6.3mm each 2 x M6 hexagon head cap screws, 4 x washers and snap ​
rings.
Power Supply - Accessories
805597
3.6 V Lithium battery
1
4 Lithium batteries for use in wireless detector base (Part No. 805593.10), wireless gateway for ​
detectors (Part No. 805594.10) and wireless universal interface (Part No. 805601.10/805602.10).
4 pcs
34
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
11
Displays and Operating Units
LED Indicator Panel
LCD Indicator Panel
System 3000
36 12
37
38-40
13
14
35
Displays and Operating Units
System IQ8Control
LED Indicator Panel
764790
Standard LED remote indicator panel
1
Approval: VdS
Additional indicator for up to 32 alarm, trouble or collective signals. Connection via an integrated ​
32-pin terminal strip. The indicator is controlled via relay contacts or semiconductor outputs with ​
positive-guided contacts in the hazard detection system. With key for lamp testing, integrated ​
buzzer and easy-to-maintain terminal card. Elegant plastic housing for surface mounting.
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Alarm current @ 12 V DC
Display
Connection terminal
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
10 ... 15 V DC
approx. 1 mA
approx. 380 mA (incl. 32 LED & buzzer)
32 LED, red
max. 1.5mm²
-5 °C ... 50 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
IP 40
ABS plastic
white (similar to RAL 9003), front blue (similar to RAL ​
5003)
approx. 1000 g
W: 270 mm H: 221 mm D: 71 mm
This indicator panel is not suitable for application as an initial warning device for the fire ​
brigade.
804791
Loop LED remote indicator panel for 32 messages
1
Approval: VdS
Same as 764790, but with integrated and wired esserbus transponder 32 LEDs for operation as a ​
remote indicating panel for the esserbus. For connection to the esserbus and powered loop in fire ​
alarm systems 8000, IQ8Control or FlexES Control.
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Alarm current @ 12 V DC
Display
Connection terminal
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
10 ... 15 V DC
approx. 1 mA
approx. 380 mA (incl. 32 LED & buzzer)
32 LED, red
1.5 mm²
-5 °C ... 50 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
IP 40
ABS plastic
white (similar to RAL 9003), front blue (similar to RAL ​
5003)
approx. 1000 g
W: 270 mm H: 221 mm D: 71 mm
Isolator (Part No. 788612) not included, please order separately.
This indicator panel is not suitable for application as an initial warning device for the fire ​
brigade.
36
www.hls-austria.com
Displays and Operating Units
System IQ8Control
1
LCD Indicator Panel
2
785101
LCD indicator panel, English
1
The LCD indicator panel is used as an add-on device for the remote display of FACP status inform­
ation of the System 8000 and IQ8Control relating to detectors and detector zones.
Event messages are displayed via LED collective indicators and on the 2-line LCD display with the ​
associated detector zone number and a programmable additional text. Each message is signaled ​
via the built-in buzzer. The buzzer can be acknowledged by pressing a button.
Up to 31 LCD indicator panels can be operated on an RS 485 bus, either directly on the RS 485 ​
interface of the basic card of FACP 8007/8000C/8000M/IQ8Control or using a common RS 485 ​
converter on another serial interface (e.g. RS ​232).
Features
• Display of zone and detector status information ​
of the FACP with additional text
• Event memory for 200 messages
• Free programming up to a max. of 4,000 addi­
tional texts, each with 2 x 20 characters
• Sequential message interrogation via scroll keys
• Monitoring of the serial interface
• Internal buzzer, can be switched off via key
• Function test of the display elements
• Potential-free relay
785107
3
4
The additional texts are programmed using the tools 8000 software package and a service PC ​
connected via the Part No. 789862.10 programming interface.
5
6
Technical Data
Operating voltage
Quiescent current
Alarm current @ 12 V DC
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
9 ... 30 V DC
approx. 30 mA
approx. 60 mA
0 °C ... 45 °C
0 °C ... 50 °C
< 95 % (non-condensing)
IP 30
plastic (ABS)
white, similar RAL 9001
approx. 750 g
W: 206 mm H: 177 mm D: 48.5 mm
7
8
9
LCD indicator panel, Polish
10
As 785101, but Polish version.
785109
LCD indicator panel, Czech
11
As 785101, but Czech version.
785113
12
LCD indicator panel, Hungarian
As 785101, but Hungarian version.
13
14
37
Displays and Operating Units
System 3000
Fire Brigade Operating Panels
784710
Fire brigade operating panel, German
1
Approval: VdS
The fire department operating unit (in accordance with DIN 14661) is an additional device ​for fire
detection systems that contains transmission units to the fire department. The ​essential display
and operating elements of the fire alarm control panel are located on the ​fire department operating
unit (FDOU). The fire fighters can handle all necessary alarm ​measures via the FDOU – so they do
not need any special training on the control panel.
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Alarm current @ 12 V DC
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
10.5 ... 30 V DC
approx. 18 mA
approx. 75 mA
0 °C ... 50
-10 °C ... 60 °C
IP 30
sheet steel
gray, similar toRAL 7032
approx. 3.4 kg
W: 255 mm H: 185 mm D: 58 mm
This fire department operating unit is not compatible with any FlexES control!
The fire brigade operating panel is supplied without locking cylinder (DIN 18252). It should be ​acquired in
accordance with the guidelines provided by the regional fire brigade.
784710.PL
Fire brigade operating panel, Polish
As 784710, but Polish version.
784710.CZ
Fire brigade operating panel, Czech
As 784710, but Czech version.
38
www.hls-austria.com
Displays and Operating Units
System 3000
1
LCD Indicator Panels
784743.CZ
2
Fire department indicating panel FAT3000, Czech
1
Approval: VdS
3
Microprocessor-controlled fire department indicating panel in compliance with DIN 14662 ​as an
additional indicator for fire alarm panels. Serial connection to the fire alarm panel via ​variable interfaces TTY, DUAL RS 485, RS232 and ESPA 4.4.4 (on board), conventional ​and redundant activation, plain text display with 4 x 20 characters, collective LED indication ​(alarm, trouble, deactivation). Simple handling with 4 buttons (buzzer OFF/level/scroll ​buttons). Additional text (> 4000
texts) can be programmed using a PC with serial interface ​connection, event memory, redundancy
via loop structure for up to 16 FAT, power supply ​and signaling pathway are monitored to prevent
short or open circuits, full functional range ​during breakdown of one circuit. The ESPA interface
enables direct connection of telecom­munication and paging systems.
ser.- IF
UB
ESPA 4.4.4
RS 232
telecom device
or pager
FACP
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Alarm current @ 12 V DC
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
4
5
8 ... 30 V DC
approx. 65 mA
approx. 125 mA
-5 °C ... 40 °C
-10 °C ... 60 °C
IP 30
sheet steel
gray, similar to RAL 7032
approx. 3.5 kg
W: 255 mm H: 185 mm D: 58 mm
6
7
8
The module can only be used when combined with a System 8000 or IQ8Control Fire Alarm ​Control
Panel.
9
Programming software "FatProgWin" is included.
784743.PL
10
Fire department indicating panel FAT3000, Polish
As 784743, but Polish version.
11
Indicator and Operating Panels in Metal Cabinets
12
784725.PL
FB information and operating system, DIN A4, Polish
1
Sheet steel housing with two doors for surface mount or flush mount installation with ​central door
opening for both door. The right-hand housing door can be individually ​opened by means of a
built-in CL1 lock. Door opening through fire brigade lock ​(suitable for half profile cylinder installation). In the left-hand door of the housing, a 784743 ​fire service indicator panel and a fire service
operating panel 784710 are installed. The ​housing is designed for holding a transmission unit or a
manual call point. The fire s​ ervice indicator panel is actuated via the serial interface in the control
panel. The fire ​service operating panel is connected to the control panel interface. A maximum of 2
x 100 ​DIN A4 / horizonal layout fire brigade route maps can be integrated.
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Alarm current @ 12 V DC
Ambient temperature
Storage temperature
Type of protection
Housing
Color
Weight
Dimensions
13
14
10 ... 30 V DC
approx. 50 mA
approx. 180 mA
-5 °C ... 40 °C
-10 °C ... 60 °C
IP30
sheet steel
red, similar to RAL 3000
approx. 15 kg
W: 710 mm H: 560 mm D: 100 mm
Only in combination with the System 8000, IQ8Control fire detection panels. For redundant ​operation,
redundancy module ADP-N3E (Part No. 784744) is required.
Double-door sheet steel housing
Fire service indicating panel 784743
Fire service operating panel 784710
39
Displays and Operating Units
System 3000
Adapter Modules
784744
Adapter module ADP-N3E
1
Microprocessor-controlled module for installation (mounting rail) in System 8000 or ​IQ8Control fire
alarm panels. In compliance with DIN 14675, the TTY interface can be used ​for redundant transmission when the adaptor is connected and when the fire department ​indicating panel FAT3000 is
used for initially informing the fire department. Additional text ​(> 4,000 texts) can be programmed
using a PC with serial interface connection.
Features
• Input: TTY from the internal FACP interface
• Output: DUAL RS 485 to the FAT interface
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Contact load relay
Connection terminal
Ambient temperature
Storage temperature
Weight
Dimensions
8 ... 30 V DC
approx. 55 mA
30 V DC / 1 A
max 2 x 0.8 mm²
-5 °C ... 40 °C
-10 °C ... 60 °C
approx. 100 g
W: 80 mm H: 150 mm D: 30 mm
The top hat rail module (part no. 788652) and the module housing for snap-on mounting rail ​(part no.
788603.10) can be used for installation. The interface is compatible with FAT3000 ​(784743). Power is
supplied by the fire alarm panel or an external power supply unit. Maximum ​data line length: 800 m.
784753
Adapter module ADP-PRS-422
1
Additional module for connecting a paging system to a series 8000/IQ8Control fire alarm system ​
with ADP-N3E. To connect the paging system via an electrically isolated RS 232 interface, an ​
ADP-PRS-422 is used.
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Dimensions
8 ... 30 V DC
approx. 5 mA
W: 100 mm H: 80 mm D: 20 mm
RS 422, max.
line length
1.000 m
FACP with adapter PCB
Part No. 784744
Connection example
Connection example
40
www.hls-austria.com
RS 232, max.
line length
15 m
Adapter module ADP- PRS-422
Part No. 784753
Nurse call
system
1
2
3
4
5
6
7
8
9
10
11
Network
essernet
42-46 12
13
14
41
Network
essernet
The essernet is a short circuit and open circuit resistant 2-wire backbone for networking ​fire detection panels from the ESSER product range. The essernet ​permits both hierarchy-restricted and
hierarchy-free programming of panels. The essernet ​has been tested and approved by the VdS.
The hardware components are listed in the ​respective equipment approvals of the fire detection
panels.
Up to 31 panels can be networked with each other in a ring loop. Superior functions and ​functions
covering different panels can be programmed. The status of the entire system ​can be read off on
anything from one to all panels as desired. Likewise, the system can be ​operated entirely from one
panel.
Networking can be carried out via a simple telecommunication cable, e.g. IY-ST-Y 2 x 0.8 ​mm, with
784840.10 or using a data cable, e.g. IBM type 1 as well as CAT5 cable, with ​784841.10. With the
essernet repeaters, cable distances of up to 3000 m between two panels ​are possible. An optical
waveguide fibre is possible with the converters, which are listed ​below.
Third-party or management systems (e.g. WINMAGplus) can be connected via the serial ​essernet
interface.
3,5 km
Segment lenght max. 1 km
Application example
42
www.hls-austria.com
Network
784840.10
essernet
1
essernet® module, 62.5 kBd for IQ8Control
Network interface module for max. 16 network participants.
Topology: Ring structure, interruption and short-circuit tolerance
1
Technical Data
Quiescent current @ 12 V DC
Cable
Cable length per segment
784841.10
2
approx. 150 mA
telecommunications cable I Y (St) Y n x 2 x 0.8 mm
1000 m (max. between 2 users)
3
essernet® module, 500 kBd for IQ8Control
4
Network interface module such as essernet module Item no. 784840.10, however for max. 31
network p​ articipants.
1
Technical Data
Quiescent current @ 12 V DC
Cable
Cable length per segment
784865
5
approx. 150 mA
IBM type 1,2,6 or similar (e.g. BELDEN 1634A)
1000 m (IBM Typ1 max. between 2 users), max. 400 ​
m when Cat3 cable or higher
6
7
essernet repeater, 62.5 kBd
1
Approval: VdS
8
The essernet repeater increases the maximum distance between two FACP in the essernet by up ​
to 1000 m. Standard telephone cables can be used as connection leads. Two repeaters can be ​
operated in line.
Technical Data
Operating voltage
Current consumption @ 12 V DC
Ambient temperature
Storage temperature
Cable
Type of protection
Housing
Air humidity
Color
Weight
Dimensions
Declaration of Performance
784843
9
8 ... 18 V DC
approx. 100 mA
-10 °C ... 70 °C
-20 °C ... 80 °C
telecommunications cable IY(St)Y n x 2 x 0.8 mm
IP65
die-cast aluminum
< 95 % (non-condensing)
gray
approx. 520 g
W: 125 mm H: 60 mm D: 80 mm
DoP-20619130701
10
11
12
essernet repeater, 500 kBd
13
1
Approval: VdS
As 784865, but with 500 kBd baud rate. IBM type 1, type 2 or type 6 cables can be used as ​
connection leads or similar.
14
43
Network
essernet
784766
FO converter for essernet, single-mode
1
The fiber optic converter for essernet, required to connect two single-mode fibers, must be ​installed
directly into the control panel’s housing. This is done by mounting it directly on the top-hat ​rail
without any further mounting fixtures.
Prefabricated connecting cable approx. 1.5 m included for connection to the essernet module in ​
the FACP.
The device should be installed as close as possible to the FACP and the connecting cable should ​
not be extended!
Features
• Two single-mode fibers are required per network ​
section.
• The fibers must be connected directly without ​
interruption (e.g. no connection via multiplexers ​
permitted)
• Fiber type G9/125 μm
• max. permitted attenuation of 17 dB corres­
ponds to a length of approx. 20 km or
• Fiber type G10/125 μm
• max. permitted attenuation of 17 dB corres­
ponds to a length of approx. 20 km
Technical Data
Operating voltage
Current consumption @ 12 V DC
Current consumption @ 24 V DC
Ambient temperature
Storage temperature
Wavelength
FO-Connector
Type of protection
Housing
Installation
Air humidity
Weight
Dimensions
9 ... 30 V DC
approx. 70 mA
approx. 35 mA
-5 °C ... 50 °C
-10 °C ... 55 °C
1300 nm
F-ST
IP40
aluminum
mounting rail
< 95 % (non-condensing)
approx. 200 g
W: 55 mm H: 24 mm D: 105 mm
Max. optical loss per FO-segment (20 km):
E9/125 µm: 17 dB, E10/125 µm: 17 dB
Accessories
788602 Top hat rail
788652 Mounting rail for FACP 8000 and IQ8Control
784855
SEI serial essernet interface EDP, unidirectional
1
The serial essernet interface can be used as a gateway to link remote computers that support the ​
ESSER data protocol (EDP). The EDP version (unidirectional) is only provided with information ​
from the essernet, remote control is not possible.The unit includes a slot for an essernet module ​
and is therefore a fully functional unit within the short circuit and open circuit resistant essernet.
Features
• Serial data rate 19.2 kBd
• RS 485 interface on-board for a max. length of ​
1,000 m
Technical Data
Operating voltage
Current consumption @ 12 V DC
Current consumption @ 24 V DC
Ambient temperature
Storage temperature
Air humidity
10.5 ... 28 V DC
approx. 60 mA
approx. 30 mA
-5 °C ... 50 °C
-10 °C ... 50 °C
< 95 % (non-condensing)
The essernet micromodule and the interface module are not included and must be ordered ​
separately in accordance with the required essernet type and the serial transmission ​standard.
Accessories
788606
Housing kit
772386
Interface-module RS 232/V 24
772387
Interface-module TTY/CL 20 mA
784840.10 essernet micromodule (62.5 kBd)
784841.10 essernet micromodule (500 kBd)
44
www.hls-austria.com
Network
essernet
784856
SEI serial essernet interface EDP, bidirectional
1
as 784855, but bidirectional with remote control options e.g. for the connection to a Building ​
Management System (BMS)
1
2
3
784859
FACP remote SEI serial essernet interface
1
The serial essernet interface is a router with internal RS 485 interface for interfacing an 8000,
IQ8Control or FlexES Control fire ​alarm panel over relatively large distances e.g. subnetworks.
Information from the connected fire alarm panel is received via a router/router link and made avail­
able in the host essernet. The first SEI is connected as Master and the second SEI as Slave.
It has a slot for an essernet loop module and is thus an integral device in the short circuit and open ​
circuit resistant essernet. For remote function, you can use the integrated RS 485 interface.
Features
• RS 485 interface on board for a max. length of ​
1,000 m
4
5
6
The essernet micromodule and the interface module are not included and must be ordered ​
separately, depending on the type of essernet and the serial transmission mode.
770432 SEI setup
7
Accessories
788606
Housing kit
772386
Interface-module RS 232/V 24
772387
Interface-module TTY/CL 20 mA
784840.10 essernet micromodule (62.5 kBd)
784841.10 essernet micromodule (500 kBd)
8
9
10
11
12
13
14
45
Network
essernet
Accessories
788606
Housing for SEI
1
Housing for the serial essernet interface (SEI).
Technical Data
Type of protection
Housing
Color
Dimensions
IP31
ABS plastic
white similar to RAL 9003, front blue similar to RAL ​
5003
W: 270 mm H: 221 mm D: 71 mm
772386
Interface-Module RS232 / V24
1
For the serial essernet interface for a length up to 15 m.
772387
Interface module TTY/CL 20 mA
1
For the serial essernet interface for a length up to 1,000 m.
013405.20
Hardware option TCP/IP converter, Ethernet RS232 / RS485
1
This hardware option is used to connect a remotely a stand-alone FACP or an essernet FACP
network essernet via a (for example) company-wide Ethernet LAN to a MBS Management Building
System e.g. WINMAG plus control center via TCP/IP. This allows the device to be used as a
protocol converter between the SEI contained on the essernet and the WINMAGplus control center
available in the Ethernet LAN.
Features
• Transmission with RS232 max. length 15 m and ​with
RS485 max. length 1,000 m
• Serial interface: RS232, RS422 or RS485 (2- and ​
4-wire), configurable via software
• Transmission speed: 300 bauds to max. 230 ​kBaud
configurable via software
• Serial connection: D-Sub 25, socket
• Ethernet interface: 10Base-T/100Base-TX
• Transmission speed: 10/100/auto Mbit, configur­able
via software
• Mode of transmission: half- /full-duplex or auto­matic,
configurable via software
• Network access: RJ45
• Supported protocol: ARP, UDP, TCP, ICMP, ​Telenet,
TFTP, AutoIP, DHCP, HTTP, SNMP, TCP, U
​ DP and
Telnet, TFTP
46
www.hls-austria.com
Technical Data
Operating voltage
Ambient temperature
Storage temperature
Air humidity
Housing
Weight
Power consumption
Dimensions
12 ... 48 V DC
0 °C ... 55 °C
-20 °C ... 75 °C
< 95 % (non condensing)
metal
approx. 340 g
1.5 W
W: 52 mm H: 80 mm D: 22 mm (housing)
W: 75.2 mm H: 80 mm D: 22 mm (with tabs)
System requirements for operation and software configuration: Windows® 2000 / XP.
Bidirectional or unidirectional data transfer depends on the SEI used, thus serial essernet interface EDP
unidirectional Part No. 784855 or bidirectional Part No. 784856. Up to 10 TCP/IP converters can be
connected per PC (Personal Computer).
1
2
3
4
5
6
7
8
9
10
11
Hazard Management System
WINMAGplus
WINMAGLite
Difference WINMAGLite vs. WINMAGplus
48-56 12
57
58
13
14
47
Management Systems
Windows management system for hazard detection systems
WINMAGplus has been specially developed to meet the requirements of managing and ​integrating
hazard detection systems on a single PC platform. WINMAGplus simultan­eously manages and
displays graphically a number of security applications, using a ​common user interface including:
fire detection technology; voice alarm public address; ​intrusion detection technology; access
control technology; video technology; rescue route ​technology/escape door control, personnel
protection systems and locating systems as ​well as fence monitoring systems. Apart from security
systems, a multitude of building ​management control systems such as lighting, elevator control
and fault detection ​systems as well as door/gate/barrier control systems can be managed and
graphically ​displayed.
1
Features
• Compatible with Windows XP Professional SP2; ​
Windows of 2003 servers; Windows Vista, 7 and 8
• Modular construction and freely programmable
• Direct control of the network devices
• List of measures to be taken for fire-fighting ​forces
• Individual allocation of usage rights incl. priority ​sched•
•
•
•
uling
Integrated simulation-functions
Extensive recording of events and operations
Visualization of messages
Up to 12 active graphics simultaneously repres­entable
• Integration of video sequences possible
• Information output via Windows print manager to ​
multiple printers etc.
• Time program/calendar function
• Integrated database standard
• Activation of other programs from WINMAGplus ​
•
•
•
•
WINMAGplus
possible
Efficient programming language (SIAS) for ​customer-specific adjustment of interface and ​processes in
case of alarm
Remote control possible via modem (optional)
10 printers per workstation possible
Multiple monitors can be used. 4 of 8 screens ​may be
selected.
Database and user interface are designed in line with current standards: messages are ​displayed
both graphically and in text format. WINMAGplus offers various application ​options, ranging from
clearly displayed messages to active control of all detection devices. ​Based on our security
networks IGIS-Loop and essernet, WINMAGplus is not only a highly ​professional system but also
the best possible integrated visual data and management ​solution.
Program:
Thanks to its modular design, WINMAGplus offers suitable software for systems of any ​size and
type of application, ranging from WINMAGplus basic package for single-station ​systems with one
subsection being connected to the WINMAGplus multi-station system ​with multiple subsections
being connected. Licensing enables the program options ​purchased and it legitimises program
use. A dongle is acquired together with a license. The ​dongle must be plugged into a parallel interface or into a USB port of the WINMAGplus ​computer. With multi-station systems, every computer
that is networked must be equipped ​with a dongle. Workstations that are not networked do not
need a dongle. TIf the dongle is removed during ​operation, WINMAGplus runs for max. 72 hours in
online mode.
Our services for installers:
Our WINMAGplus services include everything from entering alarm points to generating ​diagrams.
First of all, operators are made familiar with WINMAGplus. Then we work out ​the specifications
together with the customer and develop SIAS programs. We design ​complete application packages
and train your personnel. Until the final acceptance, we ​offer support for all installation processes
and assist you during daily operation via a ​remote maintenance tool if required.
Interfaces, drivers:
Besides our security system drivers included in our product catalog, we offer a variety of ​drivers for
all kinds of trades and manufacturers. Due to the continuously rising number of ​drivers, the current
list of drivers can be requested when required. If the driver you need is ​not available, we will
develop a driver geared to your requirements. Alternatively, all instru­ments can be connected via
the standard OPC interface. This is an international standard, ​which is supported by a multitude of
manufacturers irrespective of their product lines. For ​developing your own drivers, we can provide
you with the connection server and a ​developer’s package. Thus, individual WINMAGplus drivers
can be created.
Hardware and software requirements:
Pentium 3 GHz or higher, minimum 512 MB RAM, minimum 1 GB of hard disk space, XGA ​graphics card
with minimum 4 MB video memory, monitor with min. 1024x768 pixels, sound ​card with external speakers, Windows XP Professional SP 2, Windows 2003 Server, Vista and Windows 7 & 8, Internet ​Explorer
version 6.0 or higher.
To order WINMAGplus licenses, please use the order form found in the back of the catalog.
48
www.hls-austria.com
Management Systems
013610
WINMAGplus
1
Control center software CD WINMAGplus basic kit
WINMAGplus control center software CD for hazard detection systems, license not ​included,
compatible Windows XP Professional (SP3) 32-Bit version, Windows Server ​2003 32-/64-Bit
version, Windows Vista 32-/64-Bit version, Windows 7 & 8 32-/64-Bit version and Windows Server
2008 32-/​64-Bit version. With the aid of this basic software and the corresponding licenses, hazard ​
detection systems can be operated and managed via PC. Hazard reports are indicated in ​text form
and graphically. In this way, the PC can also be used as an electronic emergency ​control point.
2
3
For demonstration purposes only, the WINMAGplus basic version operates without a license as ​a full
version for a total of twenty 8-hour days, after which the program switches to offline mode. ​After expiry of
the test time, all connections to all components are cut off. Starting in offline ​mode does not reduce the
number of test runs. The demo mode is a full-function editing ​environment. All components function
except the online communication. Each process can also ​be tested in demo mode through simulation
and all editing functions can be used.
4
5
Please use order form printed in the appendix.
You can also download this software free of charge from our protected download area at
​www.hls.austria.com.
6
Basic Licenses
013631
7
Basic license for WINMAGplus USB port
8
This basic license is used to activate the basic software package/demo version to operate ​as unrestricted visualizing software for server workstations and for network clients. For ​interfacing control
panels to server workstations, further licenses are required (see 013601 ​– 013606, 013608,
013611, 013613, 013625).
9
Please use order form printed in the appendix.
10
Dongle for USB port
11
Upgrade Package
12
013616
WINMAG upgrade to WINMAGplus
Upgrade of a WINMAG installation from version 6 to the newest WINMAGplus control ​center software.
13
For updating WINMAG V1 - 5 please use part no. 013617 in order form.
14
Please use order form printed in the appendix.
License file
013617
WINMAG installation upgrade as of version 6
WINMAG installation upgrade to the most recent WINMAGplus control center software
version
An existing WINMAG as of version 6 can be upgraded to the most recent WINMAGplus ​control
center software version. For each installation with dongle (each connected PC) an ​upgrade
version must be separately ordered.
Please use order form printed in the appendix.
49
Management Systems
WINMAGplus
Extension Licenses
013609
WINMAGplus control center software - subsequent upgrade
This order number serves as an auxiliary number for a subsequent optional extension or ​(e.g. additional client or subsequent connection of video systems) to an existing WINMAG ​installation from V
6.0. to V10 and WINMAGplus. The appropriate licenses must be ​ordered separately. The dongle
need not be submitted.
Please use order form printed in the appendix.
013601
WINMAGplus license - intrusion detection technology
License option for WINMAG/WINMAGplus basic software. Required if intrusion detection ​systems
are connected to WINMAG.
This license may be ordered separately (subsequently) only in conjunction with the auxiliary ​number
013609. The update number of the basic license must be included when ordering. The ​license is used for
connection of the Honeywell intrusion detection systems MB/HB, 5008 and Galaxy..
Please use order form printed in the appendix.
013643
WINMAGplus license - Galaxy Dimension
License option for WINMAG/WINMAGplus basic software. Required if Honeywell Galaxy Dimension intrusion detection ​technology is connected to WINMAG.
This license may be ordered separately (as subsequent optional upgrade) only in conjunction ​with the
auxiliary number 013609. The update number of the basic license must be included ​when ordering. The
license is used for connection of the Honeywell intrusion detection systems.
Please use order form printed in the appendix.
013626
WINMAGplus license - fire detection technology
License option for WINMAG/WINMAGplus basic software. Required if fire detection ​systems are
connected to WINMAG.
This license may be ordered separately (as subsequent optional upgrade) only in conjunction ​with the
auxiliary number 013609. The update number of the basic license must be included ​when ordering. The
license is used for connection of the Honeywell IQ8Control, system 8000 ​1024, 1016 and FlexES Control
fire detection systems.
Please use order form printed in the appendix.
013603
WINMAGplus license - access control
License option for WINMAG/WINMAGplus basic software. Required if access control ​system
devices are to be connected to WINMAG (e.g. ACS 2 and ACS 8). MultiAccess and/​or IQ MultiAccess software package is also required.
This license may be ordered separately (as a subsequent optional update) only in conjunction ​with the
auxiliary number 013609. The update number of the basic license must be included ​when ordering. The
license is used for the connection of the Honeywell ACS and (IQ) M
​ ultiAccess access control systems.
Please use order form printed in the appendix.
50
www.hls-austria.com
Management Systems
013604
WINMAGplus
1
WINMAGplus license - video technology
License option for WINMAG/WiINMAGplus basic software. Required if video technology ​equipment
is to be operated via WINMAG. The crossbars can execute such commands as ​pan, zoom, tilt,
select monitor etc., depending on the model. The following video crossbars ​are currently
supported: Ernitec M 500 and M 1000; Honeywell MaxPRO 32; Philips LTC ​8x00; Fusion series II /
III; Geutebrück Vicrosoft; Geutebrück Multiscope; Honeywell ​Fusion; HDPR series; contact your
supplier for additional brands.
2
3
This license may be ordered separately (as a subsequent optional update) only in conjunction ​with the
auxiliary number 013609. The update number of the basic license must be included ​when ordering.
4
Please use order form printed in the appendix.
5
013605
WINMAGplus license - rescue route technology/escape door c
​ ontrol
License option for WINMAG/WINMAGplus basic software. Required if rescue route techno­logy/
escape door control equipment (only Honeywell Security) is to be operated via ​WINMAG.
6
The status of escape doors is graphically displayed.
7
This license may be ordered separately (as a subsequent optional update) only in conjunction ​with the
auxiliary number 013609. The update number of the basic license must be included ​when ordering. The
license is used for connecting Honeywell rescue route technology/escape ​door control equipment.
8
Please use order form printed in the appendix.
9
013608
WINMAGplus license - RTD
License option for WINMAG/WINMAGplus basic license. Enables operation of WINMAG via ​
modem, using DS 7600 and DGA 2400 to ESSER IDT (HB and MB series) and fire detec­tion
systems (1024 series).
10
This license may be ordered separately (as a subsequent optional update) only in conjunction ​with the
auxiliary number 013609. The update number of the basic license must be included ​when ordering.
11
Please use order form printed in the appendix.
12
013661
Management software WINMAGPlus licence for Honeywell DTS detector
13
License option for WINMAG/WINMAGplus basic software. Required if Honeywell DTS linear heat
detection systems is connected to WINMAG to receive, visualize fire alarm and foult states from
DTS zones.
14
51
Management Systems
WINMAGplus
Connection Server
013606
WINMAGplus license connection server
License option for WINMAG/WINMAGplus basic software. Connection Server is a software ​module
that enables the connection of a 3rd party device to WINMAG. Connection Server ​offers a convenient interface with which data and control commands can be exchanged bi-​directionally in detection point format using WINMAG.
This license may be ordered separately (as a subsequent optional update) only in conjunction ​with the
auxiliary number 013609. The update number of the basic license must be included ​when ordering.
Please use order form printed in the appendix.
013607
Connection server developers kit
This developers kit can be used to program WINMAG/WINMAGplus connections to third ​party
devices. The package contains the connection server developers kit including full ​documentation
plus a one-day training session in Albstadt (Germany).
Please use order form printed in the appendix.
Dongle for USB port and license file
OPC
013618
Data points package
Package of 500 data points for project-related allocation of OPC tags, ESPA data points, ​etc.
The data points package can only be ordered in connection with the license 013590 universal ​gateway
for PC and/or license 013611 OPC server.
Please use order form printed in the appendix.
013611
WINMAGplus license – OPC server
Option for WINMAG/WINMAGplus basic software. Required if WINMAGplus is to act as an ​OPC
server.
The OPC server license can only be ordered in conjunction with the 013618 license. This license ​may be
ordered separately (as a subsequent optional update) only in conjunction with the ​auxiliary number
013609. The update number of the basic license must be included when ​ordering.
Please use order form printed in the appendix.
013612
WINMAGplus license – OPC client
Option for WINMAG/WINMAGplus basic license. This is required if WINMAG is to display ​data
from devices with OPC interfaces.
This license may be ordered separately (as a subsequent optional update) only in conjunction ​with the
auxiliary number 013609. The update number of the basic license must be included ​when ordering.
Please use order form printed in the appendix.
52
www.hls-austria.com
Management Systems
WINMAGplus
1
Options
013613
Option - notification
2
License option for WINMAG/WINMAGplus basic license. Required if SMS (text message), ​fax or
e-mail are to be sent from WINMAG.
3
This license may be ordered separately (as a subsequent optional update) only in conjunction ​with the
auxiliary number 013609. The update number of the basic license must be included ​when ordering. An
ISDN connection (S0) as well as an ISDN card are required for the ​notification function.
4
Please use order form printed in the appendix.
013650
Option – escalation
5
Option for the WINMAG/WINMAGplus basic license. Required if short text messages ​dispatched
by WINMAG are to be acknowledged. Without acknowledgment, pre-​programmed escalation plans
can be activated.
6
This license may be ordered separately (as a subsequent optional update) only in conjunction ​with the
auxiliary number 013609. The update number of the basic license must be included ​when ordering. For
the escalation license, the 013613 notification license is required. A PC s​ ound card is required for this
function.
7
Please use order form printed in the appendix.
8
013652
Option – ability for customized interface rights (client-side)
Option for the WINMAG/WINMAGplus basic license, allowing individual assignment of ​interfaces
and rights to several operators.
9
This license may be ordered separately (as a subsequent optional update) only in conjunction ​with the
auxiliary number 013609. The update number of the basic license must be included ​when ordering.
10
Please use order form printed in the appendix.
013624
11
Option – redundance
Option for redundant connection of essernet and IGIS-Loop security networks to the ​WINMAG
server. Interface operation for redundant networks is based on master/backup ​operation and
prevents data loss in WINMAG objects in case of disruption of network ​connections caused by
cable defects or COM port failure.
12
Please use order form printed in the appendix.
013625
13
Option – client
14
1
License option for WINMAG/WINMAGplus basic license. Enables operation of one client ​station in
a computer network with one server workstation. The license must be installed at ​the server workstation. Clients require only the WINMAG software to be installed. One ​WINMAG client license is
needed per client.
This license may be ordered separately (as a subsequent optional update) only in conjunction ​with the
auxiliary number 013609. The update number of the basic license must be included ​when ordering.
Please use order form printed in the appendix.
53
Management Systems
013653
WINMAGplus
WINMAGplus – 4-monitor support option
Option for WINMAGplus basic license. Enables the allocation of 4 monitors from a choice ​of 8
monitors. This option only works with WINMAGplus.
This option requires a special graphics card with up to 8 outputs in the WINMAG hardware.
This option must be ordered per workstation which uses the multi-monitor option.
013655
WINMAGplus – AutoCAD option
Option for WINMAGplus basic license. Enables the placement of detectors and groups ​directly
from ACAD LT. The drawings are saved as dxf files. The detectors/groups are ​placed as hyperlinks
in the ACAD drawing and stored. When importing these ACAD draw­ings into WINMAGplus, the
symbols of the disciplines are automatically placed onto the ​correct position in the drawing. An
ACAD license must be provided by the customer.
Please use order form printed in the appendix.
54
www.hls-austria.com
Management Systems
WINMAGplus
1
Application Example
2
1.
WINMAGplus single station system with an essernet connection
3
FACP
4
max. 1000 m
max. 15 m
Serial
essernet
interface
5
essernet
max. 1000 m
6
WINMAGplus control centre
7
WINMAGplus software requirements:
1 x CD WINMAGplus control center software
1 x Basic license WINMAGplus control center software
1 x License fire detection technology
Part No. 013610
Part No. 013631
Part No. 013626
8
2.
9
WINMAGplus multi station system - one server and two clients
FACP
with an essernet connection
max. 1000 m
max. 1000 m
10
max. 100 m
max. 15 m
WINMAGplus server
Serial
essernet
interface
11
essernet
12
max. 1000 m
13
LAN
14
LAN
WINMAGplus client 1
WINMAGplus software requirements:
1 x CD WINMAGplus control center software
1 x Basic license WINMAGplus control center software
1 x Licence fire detection technology
2 x License WINMAGplus client
WINMAGplus client 2
Part No. 013610
Part No. 013631
Part No. 013626
Part No. 013625
55
Management Systems
WINMAGplus
Application Example
3.
FACP
WINMAGplus multi station system - one server and two clients
with a multi subsection connection
IAP
max. 15 m
Video technology
crossbar or digital
video recorder e. g.
WINMAGplus server
max. 100 m
IGIS-Loop
IGIS-LOOP
controller
IAP
LAN
WINMAGplus client 1
WINMAGplus client 2
WINMAGplus software requirements:
1 x CD WINMAGplus control center software
1 x Basic licence WINMAGplus control center software
1 x License intrusion detection technology
1 x License fire detection technology
1 x License access control technology
1 x License video technology
2 x License WINMAGplus client
Part No. 013610.10
Part No. 013631.10
Part No. 013601.10
Part No. 013626.10
Part No. 013603.10
Part No. 013604.10
Part No. 013625.10
ACS 2 plus
Access control
IQMultiAccess
4.
FACP
WINMAGplus multi station system - 1 main server,
1 redundant server, 3 client workstations
- with an essernet connection
max. 15 m
max. 100 m
WINMAGplus server 1
Serial
essernet
interfaces
max. 15 m
FACP
essernet
WINMAGplus server 2
LAN
FACP
WINMAGplus client 1
WINMAGplus software requirements:
Server 1
1 x CD WINMAGplus control center software
1 x Basic license WINMAGplus control center software
1 x License fire detection technology
4 x License WINMAGplus client
1 x License option redundance
56
www.hls-austria.com
WINMAGplus client 2
Part No. 013610.10
Part No. 013631.10
Part No. 013602.10
Part No. 013625.10
Part No. 013624.10
WINMAGplus client 3
Server 2
1 x Basic license WINMAGplus control center software
Part No. 013631.10
1 x License fire detection technology
Part No. 013610.10
Management Systems
WINMAGLite
1
Digital Recorder
Fusion e. g.
SEI
FAP
or
IAP
or
Access
Control
2
3
WINMAGLite
Application example
4
013635
Features
WINMAGLite with USB dongle
WINMAGLite is a cost effective first step to hazard detection systems management. Ease of ​operability as well as pre-defined, practical central control panel and detection point types ​facilitate the
commissioning and operation of WINMAGLite.
5
WINMAGLite is perfect for small systems for which no expansions or connection of further ​hazard
detection control panels are planned in the near future. Thus, the Lite version is ​perfectly suitable
for a broad range of applications, even for WINMAG professionals.
6
• Cost-effective management software for hazard ​detec-
Especially small objects can be professionally secured due to a combination of a hazard ​detection
system with the Honeywell video management systems of Honeywell VisiOprime. ​WINMAGLite
provides the user with almost all basic WINMAG functions. Unlike the full ​version, this version can
initially connect only one hazard detection central control panel.
• Visualizing and controlling of VisiOprime or ​Fusion
The user has access to pre-defined programs which can automatically be adjusted via a ​text editor
to the respective situation on site.
tion systems
• Visualizing and controlling of only one hazard ​detection central control panel (FDS, VAPA, IDS, R
​ RT, AC)
•
•
•
•
•
•
•
•
•
•
•
•
•
video management systems
Management of up to 500 detection points
Processing of up to 100 status reports per second
Processing of up to 100 macro processes
Connection of log and alarm printers
Information display via monitor and/or printer ​
(Windows standard printer)
Adjustable program background
Flexible, window-oriented graphics
Display and location of detectors in diagrams
Status information indicators
Pre-defined alarm reports
Simulation function
Extensive event and operation logging
Users possible
7
8
The alarm stack which was implemented in previous WINMAG versions is replaced ​through
symbols displayed in the top bar which indicate alarms. The new feature improves ​overall clarity so
that the user can react more quickly in the case of an alarm.
9
Hardware and software requirements:
Pentium processor 3 GHz or higher, min. 512 MB RAM , min. 1 GB hard disk, XGA graphics card ​with
min. 4 MB video memory, monitor with 1024 x 768 pixels or more, sound card with ​external speakers,
Windows XP Professional SP2, Vista, Windows 7 & 8 and Windows 2003 Server, Internet Explorer ​6.0 or
higher.
10
11
Please use order form printed in the catalog.
Training for this product is offered. Please contact our training department.
12
Basic CD control center software package WINMAGLite
Accessories
Please take note that for connecting one essernet is needed consisting of SEI and fire alarm system.
013636
13
WINMAGLite upgrade to WINMAGplus full version
14
If the WINMAGLite system limits have been reached, an upgrade to the full version of ​Winmagplus
is possible, since both systems have access to the same database. WINMAG ​options are not part
of the upgrade and must be ordered separately.
WINMAGplus options are not included in the upgraded version and must be ordered separately.
Please use order form on www.esser-systems.com.
57
Management Systems
Difference WINMAGLite vs. WINMAGplus
Difference WINMAGLite vs. WINMAGplus
Differences between WINMAG Lite and WINMAG plus
WINMAG Lite is the inexpensive starter version of the hazard management system WINMAG plus with reduced features. It is used
for visualization and control of a single hazard detection control panel. The following table shows the most important features of
both programs.
In this comparison, you can see whether WINMAG Lite is sufficient for an application or WINMAG plus must be used.
The data structure of WINMAG Lite and WINMAG plus is identical. It is possible to change from WINMAG Lite to the full version.
Item No.
Interfaces
I/O points per object
Setting of I/O points
Special I/O Types
Event display
Meta data
Alarm stack
User
Tool bars
SIAS-programs
SIAS language
Alarm display
Alarm criteria
Graphics
Supported monitors
Number of graphics
Graphics displayable at once
Symbol actions
Creating special symbols
Multi station functions
Mandantory
Timer programs
State monitoring
Printer allocation
Licensing
System configuration list
58
www.hls-austria.com
WINMAG Lite
013635
1 hazard detection control + any
Fusion video devices
500
individual
yes
yes
yes
not available
3 predefined, can be renamed
predefined
predefined, no special programs
no individual programming
counter and pop-ups with individual text
predefined
identical to WINMAG plus, but without
- multi-monitor
- AutoCAD
2
unlimited
13
predefined list
no
no
no
no
no
1
dongle without options
WINMAG plus
013630/13631+ Options
as desired, depending on options
32000
individual
yes
yes
yes
yes
unlimited, free definable
configurable
configurable, extensible
full featured
identical to WINMAG Lite, in addition
alarm programs with alarm stacks
configurable
several formats like
- bmp, jpg, png, emf, wmf
- AutoCAD-Integration (optional)
4 from 8 (optional)
unlimited
48
configurable, special functions
yes
yes
yes
yes
yes
15
dongle with options
1
2
3
4
5
6
7
8
9
10
11
Automatic Detectors
Series ES Detect (Intelligent non-addressable)
Series IQ8Quad (Conventional)
60-63 12
64-75
Intrinsically Safe
76-81
Base Series IQ8Quad, ES Detect
Accessories
82
13
83-95
14
59
Automatic Detectors
Series ES Detect (Intelligent non-addressable)
The ES Detect automatic detector is an intelligent non-addressable detector specifically designed ​
for operation on conventional detector groups. ES Detect ​sets new standards in conventional technology through high quality sensors with advanced detec­tion technology. These include not only
the intelligent algorithms for fire detection but also the wide ​range of different types of detectors,
including multisensor detectors OTblue and O²T. ES Detect a​ lso helps to save costs, because with
the implemented drift compensation, ES Detect can be ​operated a full eight years, instead of five
years for ordinary detectors, according to DIN 14675. ​Numerous accessories are available from
the program of the IQ8Quad detector series. The ES D
​ etect is equipped with a logo for optical
differentiation. The convenient maintenance with the ​programming software tools 8000 (in preparation) completes the full spectrum of ES Detect, from ​which the operating data of the detector (for
example, the measured values, contamination, alarm ​counters, operating hours counter ...) can be
read and stored. The detectors remain where they ​were installed, because the complete detector
group can be connected to a PC and serviced via ​the field bus interface (Part No. 789862.10).
1
117
62
Fire detector with base
Features
System benefits:
• With multisensor detectors for the detection of ​
all fires, even under the most difficult operating ​
conditions
• Up to 30 detectors per detection group.
Reliable detection:
• Uniform response sensitivity of the detector for ​
all different types of fire for the multisensor ​
detectors
• Large distance between signal and interference ​
magnitudes due to special sensor and elec­
tronics design for suppressing electromagnetic ​
influences
• Automatic adaptation to varying environmental ​
influences
• Electronic compensation of long-term influences ​
of contamination or aging
Reliable false alarm suppression:
• High reliability against false alarms by temporal ​
evaluation of different sensor criteria
• Exclusion of signal forms not typical of fires ​
through special filter algorithms
• Automatic self-monitoring of the detector elec­
tronics
• Automatic self-monitoring of sensors for function ​
and condition
Maintenance:
• Designation of the heat detector by a black ring ​
on the light pipe
• Hours of operation, alarm and fault counter in ​
each detector
• Operation data retrieval of all detectors of a ​
group with standard service PC and field bus ​
interface
• Detector LED for alarm display and as an identi­
fication display in the service (for maintenance ​
with 8000 tools)
Wide range of accessories:
• Standard socket and relay base
• Socket adapter for ceiling installation
• Dust caps optional for fire detectors and ​
detector base
• Kit for suspended mounting
60
www.hls-austria.com
Technical Data
Operating voltage
Alarm current @ 9 V DC
Air speed
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
Dimensions
8 ... 42 V DC
typ. 9 mA
0 ... 25.4 m/s
-25 °C ... 75 °C
< 95 % (non-condensing)
IP 43 (base + option)
ABS
white, similar to RAL 9010
approx. 110 g
Ø: 117 mm H: 49 mm (62 mm inkl. Sockel)
Special colors on request!
In order to pass through existing wires, the WAGO grips (e.g., type 243-204 (O 0.5-1 mm) or ​
273/104 (0.75-2.5 mm²)), can be integrated into the detector base.
ES Line
Detector base is not supplied as standard
Z1
Z2
Accessories
767800 assembly bracket
805590 standard IQ8Quad detector base
805591 detector base with IQ8Quad relay contact
Z3
Z4
Spur max. 1,000 m per zone
FlexES Control
esserbus
loop
length
max.
3.5 km
Z1
Z2
Z3
Z4
Automatic Detectors
800171
Series ES Detect (Intelligent non-addressable)
1
Fixed heat detector ES Detect
Approval: G 213068
1
Automatic heat detector with fast semiconductor sensor for reliable detection of fires with ​distinctive heat. Fire detector with decentralized intelligence, automatic function self-test, alarm ​and
operations data storage and alarm display. A remote indicator can also be connected.
2
Technical Data
Quiescent current @ 9 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
3
approx. 25 μA
max. 30 m²
max. 7.5 m
-20 °C ... 50 °C
EN 54-5 A1S
4
Special marking for heat detector on the light pipe: black ring
800177
5
Fixed heat detector ES Detect, Class B
6
Approval: G 213067
1
As 800171, however, for increased response temperature according to EN 54-5 class B.
Technical Data
Quiescent current @ 9 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
7
approx. 25 μA
max. 30 m²
max. 6 m
-20 °C ... 65 °C
EN 54-5 BS
8
Special marking for heat detector on the light pipe: black ring
800271
9
Rate-of-rise detector ES Detect
10
Approval: G 213069
1
Automatic heat detector with fast semiconductor sensor for reliable detection of fires with rapid ​
temperature rise and integrated maximum value function for the recognition of fires with slow ​
temperature rises. Fire detector with decentralized intelligence, automatic function self-test, alarm ​
and operations data storage and alarm display.
A remote indicator can also be connected.
Technical Data
Quiescent current @ 9 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
11
12
approx. 25 μA
max. 30 m²
max. 7.5 m
-20 °C ... 50 °C
EN 54-5 A1R
13
Special marking for heat detector on the light pipe: black ring
14
61
Automatic Detectors
800371
Series ES Detect (Intelligent non-addressable)
Optical smoke detector ES Detect
Approval: G 213066
1
Scattered-light smoke detector for reliable early detection of fires. Fire detector with decentralized ​
intelligence, automatic function self-test, automatic environmental adaptation, alarm and operating ​
data storage and alarm display.
A remote indicator can also be connected.
Technical Data
Quiescent current @ 9 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
800375
approx. 30 μA
max. 110 m²
max. 12 m
-20 °C ... 72 °C
EN 54-7
OTblue multisensor detector ES Detect
Approval: G 213065
1
Multisensor detector with integrated optical smoke and heat sensor. The optical measurement ​
chamber is equipped with a novel sensor which allows the detection of open fires, smoldering fires ​
and fires with high heat.
The classical ionization detector is replaced by these detection methods, especially in open fires. ​
This detector is also capable of detecting test fires TF1 and TF6 described in the EN 54-9:1982.
The OTblue multisensor is a fire detector with temporal signal analysis, weighted combination of ​
sensor data, decentralized intelligence, automatic function self-test, automatic environmental ​
adaptation, alarm and operating data storage and alarm display.
A remote indicator can also be connected.
Technical Data
Quiescent current @ 9 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
800374
approx. 35 μA
max. 110 m²
max. 12 m
-20 °C ... 50 °C
EN 54-7/-5 A2, CEA 4021
O2T multisensor detector ES Detect
Approval: G 213070
1
Multisensor detector with two integrated optical smoke sensors with different scattered light angles ​
as well as additional heat detector sensor evaluation for detecting anything from smoldering fires to ​
open fires with uniform response characteristics. Compares smoke sensor signals for smoke clas­
sification and reduction of false alarms from water vapor or dust, for example. Due to its excellent ​
detection properties, the detector is also capable recognizing test fires TF1 and TF6 described in ​
the standard. The O²T multisensor detector is also suitable for higher application temperatures of ​
up to +65° C.
A remote indicator can also be connected.
Technical Data
Quiescent current @ 9 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
62
www.hls-austria.com
approx. 45 μA
max. 110 m²
max. 12 m
-20 °C ... 65 °C
EN 54-7/-5 B, CEA 4021
Automatic Detectors
Series ES Detect (Intelligent non-addressable)
1
800361.10
1
Optical Smoke Detector Detect ES with relay contact, 48 V DC ​operation
The threshold value detector with relay contact 800361.10 comprises an optical smoke detector ​
800371 from the ES Detect series and a detector base 805592 which enables a direct connection ​
to a 48 V DC power supply. The detector therefore does not need to be operated in connection ​
with a fire alarm control panel.
If the detector detects a fire alarm, a floating relay contact activates to transmit the alarm. The ​relay
contact is normally open (NO) by default, but can also be configured as normally closed (NC) ​with
a solder strap on the circuit board base.
A typical use for this detector is to monitor mobile communication stations, e.g. BTS base trans­
ceiver stations.
Take note, the Detector base with relay output for ES Detect 805592 is included in the scope of ​
delivery!
Technical Data
Operating voltage
Quiescent current
Current consumption
Contact load relay
Area to be monitored
Height to be monitored
Air speed
Application temperature
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
Detector specification
Dimensions
2
3
4
5
42 ... 58 V DC
approx. 0.051 mA (@ 48 V DC)
max. 9 mA
30 V DC / 1A, 60 V DC / 0,45 A
max. 110 m²
max. 12 m
0 ... 25.4 m/s
-20 °C ... 72 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
IP 43 (with base and option)
ABS
white, similar to RAL 9010
approx. 110 g (ca. 190 g incl. base)
EN 54-7
Ø: 117 mm H: 49 mm (incl. base 62 mm)
6
7
8
9
Replacement for Part No. 761306
805592
1
10
Detector base with relay output for ES Detect 800631.10
Detector base with relay contact output, for ES Detect detector family. Suitable for 48 V DC opera­
tion.
Contact: floating normally open or normally closed, selectable via coding strap, factory setting: ​
normally open.
A typical use for this base with ES Detect detector is to monitor mobile communication stations.
Technical Data
Operating voltage
Contact load relay
Connection terminal
Application temperature
Storage temperature
Air humidity
Material
Color
Weight
Dimensions
11
12
42 ... 58 V DC
30 V DC / 1A, 60 V DC / 0,45 A
Ø 0,6 mm ... 2 mm²
-20 °C ... 72 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
ABS
white, similar to RAL 9010
approx. 80 g
Ø: 117 mm H: 24 mm (incl. detector 62 mm)
13
14
Cable entry on the side or bottom plate.
For looping existing wires, for example, the type 243-204 WAGO terminals (Ø 0.5 mm Ø 1.0 ​
mm) or 273 to 104 (0.75 mm-2.5 mm) are used.
Not for use with IQ8Quad detectors!
Not for use in esserbus and powered loop ringbus!
Contained in Part No. 800361.10
Replacement for Part No. 781582
63
Automatic Detectors
Series IQ8Quad (Intelligent Addressable)
Automatic intelligent fire detectors with high reliability and low power consumption used for ​
premises and items of property with medium and high concentration of valuable assets.
Detector series IQ8Quad features, system advantages
• Designed for optimal operation on System 8000 and IQ8Control fire alarm systems
• with multisensor fire detectors for the detection of all types of fires, even under the most difficult ​
operating conditions.
• Detector with and without loop isolator
Different options of installation
• wiring in loop and spur combination, e.g.
• maximum number of detectors with cable lengths of up to 3,500 m with installation cable for fire ​
detection, e.g. cables I-Y(St)Yn x 2 x 0.8 mm
• up to 127 detectors and detector zones per loop installation
• up to 32 detectors per zone
Easy commissioning
• automatic detector addressing
• fixed address assignment of detector location, even after detectors have been replaced or added
• localization of wire breaks and short circuits on loop
• detector-LED used as alarm indicator and as an indicator for detectors in service
• adaptation to changing operating conditions
• dedicated LED for indicating operation (green LED)
• disconnection of individual detectors, detector zones and detection areas
• disconnection of individual sensors or several sensors at once within a multisensor fire detector; ​
either manually or depending on programmed time of the day
Automatic adaptation to varying environmental conditions
• compensation of changing levels of air pressure, humidity, smoke c• centration according to the ​
double chamber principle
• electronic compensation of long-term influences like aging or pollution
Reliable detection
• constant alarm sensitivity of multisensor fire detector for all types of fire
• large signal to noise ratio due to the special design of the sensors and the electronics to suppress​
electromagnetic interference
Reliable false alarm suppression
• high immunity against false alarms by means of timed evaluation of different sensor criteria
• signal patterns not typical for fires are eliminated by using special filter algorithms
• automatic self-monitoring of detector electronics
• continuous loop monitoring even during short-circuits through isolating the relevant segment
• automatic monitoring of all sensors to guarantee operational capacity and correct condition.
Increased operating reliability
• short-circuit and wire break tolerant through monitoring from both ends of the loop
• alarm decision inside detector
• fail-safe circuit activated if communication fails
Maintenance
• automatic maintenance request
• heat detector identification through a black circle on the light transmission plate
• multisensor gas detector identification through a golden loop on the circle transmission plate
• operating time-, alarm- and fault counter in each detector
• automatic, cyclic loop check
• complete status interrogation from the control panel
• interrogation of operating data from all detectors on loop via standard service PC and detector ​
interface
Comprehensive range of accessories
• standard detector base and relay base
• base adapter for ceiling mounting
• dust cover for fire detector or detector base
• kit for suspended ceiling mounting
• RF base
64
www.hls-austria.com
Automatic Detectors
Series IQ8Quad (Intelligent Addressable)
1
Detectors w/o Integrated Alarm Devices
117
62
Fire detector with base
Technical Data
Alarm current w/o communication curtain
Air speed
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
Dimensions
2
approx. 18 mA
0 ... 25.4 m/s
-25 °C ... 75 °C
< 95 % (non-condensing)
IP43 (with base + option)
ABS plastic
white, similar to RAL 9010
approx. 110 g
Ø: 117 mm H: 49 mm (62 mm incl. base)
3
4
Special-color on demand
The detectors Part No. 802271, 803271, 802371, 803371, 802373, 802374 and 803374 are ​
approved in the scope of the DIBt system authorization for the operation with an Automatic ​
Door System.
5
Detector base is not supplied as standard
6
Accessories
767800 Mounting bracket
805590 Standard detector base for IQ8Quad
805591 Detector base with relay contact for IQ8Quad
802171
7
Fixed heat detector IQ8Quad with isolator
8
1
Approval: VdS, CNBOP, BOSEC
9
Automatic heat detector with a single thermistor to sense the air temperature around the detector. ​
Fast semiconductor sensor guarantees reliable detection of fires with strong heat generation. Ideal ​
for sensing in environments that are dirty or smoky under normal conditions, as well it is unaffected ​
by wind or atmospheric pressure. Intelligent fire detector with decentralized intelligence, automatic ​
function self-test, CPU failure mode, alarm and operating data memory, alarm indicator, soft-​
addressing and operating indication.
The detector is provided with an integrated isolator. A parallel detector indicator can be connected.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
Declaration of Performance
10
11
8 ... 42 V DC
approx. 40 μA
approx. 220 μA @ 42 V
max. 30 m²
max. 7.5 m
-20 °C ... 50 °C
EN 54 - 5 A1S / -17
DoP-20102130701
12
13
Special marking for heat detector on the light pipe: black ring.
802177
14
Fixed heat detector IQ8Quad (class B), with higher operating t​ emperature
with isolator
1
Approval: VdS
Same as 802171, but for increased operating temperature according to EN 54-5 class B.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
Declaration of Performance
8 ... 42 V DC
approx. 40 μA
approx. 220 μA @ 42 V
max. 30 m²
max. 6 m
-20 °C ... 65 °C
EN 54-5 BS / -17
DoP-20411130701
Special marking for heat detector on the light pipe: black ring.
65
Automatic Detectors
802271
Series IQ8Quad (Intelligent Addressable)
Rate-of-rise heat detector IQ8Quad with isolator
1
Approval: VdS, CNBOP, BOSEC
Automatic heat detector with a single thermistor to sense the air temperature around the detector. ​
Fast semiconductor sensor guarantees reliable detection of fires with rapidly rising temperatures ​
and integrated fixed temperature function for the detection of fires with slowly rising temperatures. ​
Ideal for sensing in environments that are dirty or smoky under normal conditions, as well it is unaf­
fected by wind or atmospheric pressure. Intelligent fire detector with decentralized intelligence, ​
automatic function self-test, CPU failure mode, alarm and operating data memory, alarm indicator, ​
soft-addressing and operating indication.
The detector is provided with an integrated isolator. A parallel detector indicator can be connected.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
Declaration of Performance
8 ... 42 V DC
approx. 40 μA
approx. 220 μA @ 42 V
max. 30 m²
max. 7.5 m
-20 °C ... 50 °C
EN 54-5 A1 / -17
DoP-20103130701
Special marking for heat detector on the light pipe: black ring.
802371
Optical smoke detector IQ8Quad with isolator
1
Approval: VdS, CNBOP, BOSEC
Optical smoke detector which works using the light scatter principle to guarantee safe and early ​
detection of fire. Responds well to slow-burning, smouldering fires. Intelligent fire detector with ​
decentralized intelligence, automatic function self-test, CPU failure mode, alarm and operating ​data
memory, alarm indicator, soft-addressing and operating indication. The detector is provided ​with an
integrated isolator. A parallel detector indicator can be connected.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
Declaration of Performance
802373
8 ... 42 V DC
approx. 50 μA
approx. 280 μA @ 42 V
max. 110 m²
max. 12 m
-20 °C ... 72 °C
EN 54-7 / -17
DoP-20104130701
OT multisensor fire detector IQ8Quad with isolator
1
Approval: VdS
Multisensor fire detector with integrated optical sensor and heat sensor which give both a ​
combined signal as well as a separate heat signal for improved false alarm management, with ​
time-controlled signal analysis and weighted data combination of both detector functions for ​detecting smoldering fires and fires with extreme heat generation. Intelligent detector with decent­ralized
intelligence, self-function test, CPU redundancy mode, automatic adaptation to the environ­ments,
alarm and operating data storage, alarm indication and soft addressing.
The loop isolator is integrated in the detector. A parallel detector indicator is additionally attachable.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
Declaration of Performance
66
www.hls-austria.com
9 ... 42 V DC
approx. 50 μA
approx. 280 μA @ 42 V
max. 110 m²
max. 12 m
-20 °C ... 50 °C
EN 54-7/-5 A2 /-17, CEA 4021
DoP-20111130701
Automatic Detectors
802374
Series IQ8Quad (Intelligent Addressable)
1
O2T multisensor fire detector IQ8Quad with isolator
Approval: VdS, CNBOP, BOSEC
2
Multisensor fire detector provided with two built-in optical smoke sensors with different scattered ​
light angles as well as additional heat detector sensor evaluation to guarantee the detection of ​
different types of fire from smoldering fires to open fires with constant sensitivity level. Smoke ​
sensor signal identification to ensure smoke classification and reduction of false alarms caused by ​
interferences, for instance, water vapor or dust. Used when early and reliable fire detection is ​
requested. Because of its excellent detection characteristics and enhanced false alarm manage­
ment, the detector is also able to identify the standardized TF1 and TF6 test fires. The O²T multis­
ensor fire detector is also suitable for applications with higher temperatures of up to +65 °C. The ​
detector is provided with an integrated isolator. A parallel detector indicator can be connected.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
Declaration of Performance
802375
3
4
5
8 ... 42 V DC
approx. 60 μA
approx. 330 μA @ 42 V
max. 110 m²
max. 12 m
-20 °C ... 65 °C
EN 54-7/-5 B /-17, CEA 4021
DoP-20105130701
6
7
OTblue multisensor fire detector IQ8Quad with isolator
8
1
Approval: VdS
9
Multisensor fire detector with integrated optical sensor and heat sensor with enhanced false alarm ​
management. The optical measurement chamber is provided with a patented developed sensor ​
technology using a high-sensitive blue LED (instead of the commonly used red LED in Optical ​
smoke detectors), enabling the detection of open fires, smoldering fires and fires with high heat ​
generation. Especially for open fires, the classical ionization technology implemented in ionization ​
detectors is replaced by the unique detection technology, unlike ionization detectors, this sensor ​
works without a radioactive element which causes problems at the time of refuse disposal. The ​
detector is capable of identifying the TF1 and TF6 test fires described in the EN 54-9:1982 ​specification. Well suited for sensitive environment, detection of invisible up to large aerosols.
The OTblue multisensor is an intelligent detector with time-related signal analysis, signal correla­
tion of the sensor data, decentralized intelligence, automatic function self-test, CPU failure mode, ​
automatic adaptation to environmental conditions, alarm and operating data memory, alarm indic­
ator and soft-addressing.
The detector is provided with an integrated isolator and a parallel detector indicator can be ​
connected.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Material
Detector specification
Declaration of Performance
10
11
12
13
9 ... 42 V DC
approx. 50 μA
approx. 280 μA @ 42 V
max. 110 m²
max. 12 m
-20 °C ... 50 °C
ABS
EN 54-7/-5 A2 /-17, CEA 4021
DoP-20113130701
14
67
Automatic Detectors
802473
Series IQ8Quad (Intelligent Addressable)
OTG multisensor fire detector (CO) IQ8Quad with isolator
1
Approval: VdS
Multisensor fire detector with integrated smoke detector, heat detector and gas sensor (CO) with ​
enhanced false alarm management, for preventive and early detection of deep-seated smouldering ​
fires which give a lot of CO as well as flaming fires through combined evaluation of scattered light, ​
temperature and gas. An alarm is actuated at carbon monoxide (CO) concentration levels that are ​
life-threatening for humans. Less susceptible to false alarms caused by dust, as well earliest and ​
reliable detection of fire development due to the additional detection of CO. Also a Technical Alarm ​
(TAL) can be programmed with the flexible programmable CO threshold up to 150 ppm. The ​
detector is provided with an integrated isolator. A parallel detector indicator can be connected.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Quiescent current @ FACP battery
CO pre-alarm
CO alarm
Area to be monitored
Height to be monitored
Application temperature
Detector specification
Declaration of Performance
8 ... 42 V DC
approx. 65 μA
approx. 225 μA @ 27,5 V
approx. 360 μA @ 42 V
approx. 75 ppm
approx. 100 ppm
max. 110 m²
max. 12 m
-20 °C ... 50 °C
EN 54-7/-5 A2 /-17, CEA 4021
DoP-20115130701
In the course of installation, we recommend testing the integrated CO sensor with our CO ​
test gas (Part No. 805583) or CO capsule (Part No. 805553).
Durability CO sensor: 5 years
Technical alarm range CO: 10 ppm … 150 ppm
Gas sensors (CO) mainly react to the carbon monoxide arising from a fire (CO). They have, ​
however, also a cross sensitivity to other gases, as for example hydrogen (H2), acetylene ​
(C2H2) or nitric oxide (NO).
Special marking for gas detector on the light pipe: golden ring.
68
www.hls-austria.com
Automatic Detectors
Series IQ8Quad (Intelligent Addressable)
1
Detector with Integrated Alarm Devices
Features
Detection
• The reliable O²T multisensor principle for ​consistent
response performance at the highest ​level of security
against false alarms
Flash lamp
• Loop powered - no need for external power ​supply
• No additional short address
• Automatic synchronization of various IQ8Quad ​alarm
signaling devices
• High flash energy
Sounder
• Loop powered - no need for external power ​supply
• No additional short address
• Automatic synchronization of various IQ8Quad ​alarm
signaling devices
• Maximum sound level: 92 dB (A) at 1 m
• Maximum sound pressure can be set
• Multiple signal patterns can be combined to one ​signal
• Signal pattern and repetition rates can be set
• 20 different signal tones, incl. DIN-tone
Speech massage with sounder
• Loop powered - no need for external power ​supply
• No additional short address
• Automatic synchronization of various IQ8Quad ​alarm
signaling devices
• Maximum sound level: 92 dB (A) at 1 m
• Maximum sound pressure can be set
• Multiple signal patterns can be combined to one ​signal
• Signal pattern and repetition rates can be set
• 20 different signal tones, incl. DIN-tone
• Speech messages can be played in up to 5 ​languages
• 5 alarm messages per languages are prepro­grammed
The IQ8Quad smoke detectors with built-in alarm device incorporate up to 4 different func­tionalities
(detect, flash, sound, and/or speech) depending on the type (O²T/F, O²T/So, O²T/​Sp, O²T/FSp) of
detector.
2
- fire detection as per EN 54-7
- integrated heat sensor as per EN 54-5
- optical alarm via flash lamp
- acoustic alarm via sounder as per EN 54-3/A2
- acoustic alarm speech messages as per EN 54-3/A2
- short-circuit isolator as per EN 54-17
3
4
Detection
Multisensor detectors with two built-in optical smoke sensors with different scattered light ​angles as
well as additional heat detector sensor evaluation for detecting everything from ​smouldering fires
to open fires with consistent response performance. Smoke sensor ​signal identification to ensure
smoke classification and reduction of false alarms caused, ​for instance, by water vapor or dust.
Each detector is provided with an integrated isolator.
5
6
Alarm signaling
The alarm signaling device is activated by the control panel. No further short address ​needs to be
allocated. It is programmed with tools 8000 as of software version 1.05.
7
Alarm tone / speech message programming
For detectors with speech message and/or alarm tone function with up to five language ​options, up
to 4 signals can be programmed. Two signals are reserved for alarm signaling ​and evacuation in
the case of fire. Two further signals can be programmed for other events. ​Each signal can consist
of up to four signal components, enabling one signal to be ​programmed as a DIN tone combined
with subsequent speech messages in three different ​languages.
8
9
Alarm tones can be chosen from a table with various tone types. For application in schools, ​a
break signal to signify the breaks between class can be activated.
Four different speech messages, each in three languages, are available:
10
- "An incident has been reported in the building. Please await further instructions.”
- "Attention” please. This is an emergency. Please leave the building by the nearest avail­able exit.”
11
- "This is a fire alarm. Please leave the building immediately by the nearest available exit.”
- “This is a test message. No action is required. “
12
When the basic setting is selected, signals / signal components can be continuously ​repeated until
the signalling function is interrupted by the control panel. They can also be ​programmed with a
repetition rate of one to three times. Thus, the break signal in schools ​can be deliberately set to
only one repetition. In the same way, the total signal can be set to ​continuous repetition, with the
DIN tone being played only once while subsequent speech ​messages are played up to three times.
13
14
Sound pressure programming
The sound level [dB (A)] can be set to eight levels, from approximately 64dB (A) to approx­imately
92dB (A).
69
Automatic Detectors
Series IQ8Quad (Intelligent Addressable)
All the security you need in one housing with four functions: detection, flasher, sounder ​and speech
alarm.
All IQ8Quad detectors with built-in alarm devices can only be operated on the powered loop. For ​physical
reasons, an increased sound level leads to a higher current consumption rate of the ​alarm device, the
respective load factor must be considered when calculating the maximum ​number on the loop. Altogether
up to 127 bus devices per loop can still be connected.
Please consider that extra training is required when dealing with IQ8Quad with a built-in alarm ​device.
The training includes installation planning and commissioning techniques. For further ​information take a
look at our training brochure. Information concerning the calculation can be ​found in the "Project Planning Support“ chapter.
Signals
70
www.hls-austria.com
signal 1
(evacuation)
sequence 1
sequence 2
sequence 3
sequence 4
signal 2
(alarm)
sequence 1
sequence 2
sequence 3
sequence 4
signal 3
(event 1)
sequence 1
sequence 2
sequence 3
sequence 4
signal 4
(event 2)
sequence 1
sequence 2
sequence 3
sequence 4
Automatic Detectors
Series IQ8Quad (Intelligent Addressable)
1
Detector with Integrated Alarm Devices
Country code
acc. to ISO
3166 -Alpha-2
Language
code acc.
to ISO 639-1 Evacuation 1
de
Germany
(DE)
en
Great Britain
(GB)
fr
France
(FR)
es
Spain
(ES)
it
Italy
(IT)
Evacuation 2
Alarm
Dies ist ein
Feueralarm. Bitte
verlassen Sie das
Gebäude umgehend über die
nächsten Fluchtwege. Die Feuerwehr ist alarmiert.
Achtung, Achtung!
Dies ist eine Gefahrenmeldung. Bitte
verlassen Sie das
Gebäude über die
nächsten
Ausgänge.
Achtung, im Gebäude ist eine
Gefahrensituation
gemeldet worden.
Bitte bleiben Sie
ruhig, und warten
Sie auf weitere
Anweisungen.
This is a fire alarm.
Please leave the
building immediately by the nearest
available exit.
Attention please.
This is an emergency. Please leave the
building by the
nearest available exit.
An incident has
been reported in the
building. Please
await further
instructions.
Ceci est une alarme
incendie,veuillez
évacuer
immédiatement les
locaux par la sortie
la plus proche.
Votre attention s'il
vous plaît, ceci est
une alarme. Veuillez
évacuer les locaux
par la sortie la plus
proche.
Un incident est
signalé dans le
batiment. Merci de
garder votre calme
et attendez les
prochaines
instructions.
Esto es una alarma
de incendio.
Abandonen
por favor el edificio
inmediatamente
por la salida de
evacuación
más cercana.
Atención. Esto es
una emergencia.
Por favor
abandonen el
edificio por la
salida de
evacuación
más cercana.
Attenzione.
Allarme incendio.
Abbandonare
l'edificio tramite
l'uscita di
emergenza più
vicina.
Attenzione.
Allarme in corso.
Vi preghiamo di
recarvi presso
l'uscita di
emergenza più
vicina.
2
Test-message
All-Clear
Dies ist eine
Testdurchsage.
Die Gefahrensituation
ist jetzt behoben. Wir
entschuldigen uns
für jegliche
Unannehmlichkeiten.
This is a test
message.
No action is
required.
The emergency is
now cancelled. We
apologize for any
inconvenience.
3
4
5
Ceci est un test.
L'alarme est à
présent annulée.
Veuillez nous excuser
pour le désagrément.
Atención, se ha
reportado un
incidente
en el edificio.
Aguarden por favor
otras instrucciones.
Esto es un
mensaje
de prueba.
No se requiere
ninguna acción.
La emergencia ha
sido cancelada.
Pedimos disculpas
por las molestias
causadas.
Attenzione.
E' stato rilevato un
allarme.Ulteriori
disposizioni vi
verranno
comunicate
appena possibile.
Attenzione.
E' in corso una
prova di allarme.
Non è richiesta
alcuna azione.
6
7
8
Attenzione. Cessato
allarme.La situazione
di normalità è stata
ripristinata.
9
10
Standard speech messages of IQ8Quad detectors and IQ8Alarm - for other languages also refer to the appendix!
No.
1
Description
School bell
Frequency
complex
Pulse rate
11
complex
2
FP 1063.1 Telecoms
BS 5839 Pt1
Alternating 800 / 970 Hz at 2 Hz
3
BS 5839 Pt1
Alternating 800 / 970 Hz at 1 Hz
f
4
BS 5839 Pt1
Intermittent 970 Hz at 1 Hz 0.5 sec.
f
5
BS 5839 Pt1
Intermittent 2850 Hz at 1 Hz 0.5 sec.
f
f
0.25 sec.
0.25 sec.
t
12
0.5 sec.
1.5 sec.
0.5 sec.
0.5 sec.
t
1.5 sec.
0.5 sec.
0.25 sec.
6
BS 5839 Pt1
Intermittent 970 Hz 1/4 sec. ON - 1 sec. OFF
f
7
BS 5839 Pt1
Continuous 970 Hz
f
8
BS 5839 Pt1
Sweep tone 800 Hz tp 970 Hz at 7 Hz
f
9
BS 5839 Pt1
Sweep tone 800 Hz to 970 Hz at 1 Hz
f
1.0 sec.
10
DIN Tone
DIN 33404 Part 3
1200 - 500 Hz at 1 Hz
f
1.0 sec.
11
French fire sound
554 Hz / 100 ms + 440 Hz / 400 ms + 10 %
f
12
NL - Slow Whoop
500 Hz - 1200 Hz at 3.5 sec. break of 0.5 sec.
f
13
US - Horn
Continuous 485 Hz
f
14
US - Horn with
Temporal Pattern
Intermittent 485 Hz
(0,5 sec. ON; 0.5 sec. OFF; 3 times; 1.5 sec. OFF; Repeat)
f
15
US - March
Time
Alternating 485 Hz
(0,25 sec. ON; 0.25 sec. OFF; Repeat)
f
16
US - Slow
Whoop
Sweep tone 500 Hz to 1200 Hz
(4.0 sec. ON; 0.5 sec. OFF; Repeat)
f
17
US - Siren
f
18
US - Hi/Lo
Sweep tone 600 Hz to 1200 Hz
(1,0 sec. ON, Repeat)
Alternating 100 Hz / 800 Hz
(0.25 sec. ON; Alternate; 0.25 sec. ON; Alternate; Repeat)
19
US - NFPA
Whoop
IMO
GA-Signal
Sweep tone 422 Hz to 775 Hz
(upwards sweep 0.85 sec.; 3 times; 1 sec. OFF; Repeat)
Intermittent 800 Hz (1,0 sec. ON; 1,0 sec.
OFF: 7 times; 2.0 sec. ON: 2.0 sec. OFF; Repeat)
f
20
t
0.5 sec.
0.5 sec.
t
1.0 sec.
13
t
t
10 ms
t
14
t
t
0.4 sec. 0.1 sec.
t
3.5 sec.
0.5 sec.
t
t
0.5 sec.
1.5 sec.
0.5 sec.
t
0.25 sec.
0.25 sec.
t
4.0 sec. 0.5 sec.
t
1.0 sec.
t
f
0.25 sec.
0.25 sec.
0.85 sec.
t
1.0 sec.
t
f
1.0 sec.
1.0 sec.
t
IQ8Quad detectors and IQ8Alarm tone table
71
Automatic Detectors
Series IQ8Quad (Intelligent Addressable)
Detector with Integrated Alarm Devices
117
65
Fire detector with base
Technical Data
Operating voltage
Area to be monitored
Height to be monitored
Air speed
Application temperature
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
Dimensions
8 ... 42 V DC
max. 110 m²
max. 12 m
0 ... 25.4 m/s
-20 °C ... 65 °C
-25 °C ... 75 °C
≤ 95 % (without condensation)
IP 42
ABS plastic
white, similar to RAL 9010
approx. 145 g
Ø: 117 mm H: 59 mm
Ø: 117 mm H: 67 mm (incl. base)
Detector bases are not supplied as standard.
The 769836 demo package is available for presentations. Further data can be viewed in the ​accessories
section for automatic detectors.
Special-colors on demand!
It is not possible to use the detector base with relay (part no. 805591).
When connected with parallel indicator does not allow to program parallel indicator.
Detector base is not supplied as standard
Accessories
767800 Mounting bracket
805590 Standard detector base for IQ8Quad
IQ8Control C
flash
signal
speech
esserbus-PLus
Loop length max. 3.5 km
speech
esserbus transponder
flash
sound
Application example
72
www.hls-austria.com
speech
Automatic Detectors
802382
Series IQ8Quad (Intelligent Addressable)
1
O/So optical smoke detector IQ8Quad
1
Approval: VdS
O/So optical smoke detector IQ8Quad with integrated sounder
2
Scatter smoke detector for safe and early detection of smouldering fires with light smoke ​generation. Intelligent detector with decentralised intelligence, automatic function self-test, ​CPU failure
mode, alarm and operating data memory, alarm indicator, soft-addressing and ​operating indication.
The detector is provided with a loop isolator.
3
Along with smoke detection components, the detector is provided with a built-in sounder.
Technical Data
Quiescent current @ 19 V DC
Load factor
Sound level
Detector specification
Specification
4
approx. 50 μA
2
max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone
EN 54-7, EN 54-17
EN 54-3 acoustic signaling device
5
Not suitable for application in detector base 805591!
802383
6
O2T/F multisensor IQ8Quad
7
1
Approval: VdS
O²T/F multisensor IQ8Quad with integrated flasher
In addition to smoke detection with the conventional O²T multisensor technology, the ​detector is
provided with a built-in flash lamp.
8
Technical Data
Quiescent current @ 19 V DC
Load factor
Lighting energy
Strength of light
Signal flashing lamp
Detector specification
9
approx. 75 μA
2
approx. 3 Y
max. 15,8 cd peak / 2,63 cd effective
red
EN 54-7/-5 B/-17, CEA 4021
10
Not suitable for application in detector base 805591!
802384
11
O2T/So multisensor IQ8Quad
12
1
Approval: VdS
O²T/So multisensor IQ8Quad with integrated sounder
13
In addition to smoke detection with the conventional O²T multisensor technology, the ​detector is
provided with a built-in alarm signalling device. The sound level can be set to ​eight different levels.
14
Technical Data
Quiescent current @ 19 V DC
Load factor
Sound level
Type of protection
Detector specification
Specification
approx. 80 μA
2
max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone
IP 42
EN 54-7/-5 B/-17, CEA 4021
EN 54-3 acoustic signaling device
Not suitable for application in detector base 805591!
73
Automatic Detectors
802385
Series IQ8Quad (Intelligent Addressable)
O2T/FSp multisensor IQ8Quad
1
Approval: VdS
O²T/FSp multisensor IQ8Quad with integrated flasher, sounder and speech
In addition to smoke detection with the conventional O²T multisensor technology, the ​detector is
provided with a built-in voice alarm device. It can be set to eight different levels.
Technical Data
Quiescent current @ 19 V DC
Load factor
Sound level
Lighting energy
Strength of light
Signal flashing lamp
Detector specification
Specification
approx. 90 μA
3
max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone
approx. 3 Y
max. 15,8 cd peak / 2,63 cd effective
red
EN 54-7/-5 B/-17, CEA 4021
EN 54-3 acoustic signaling device
EN 54-3 acoustic speech signallng device
Not suitable for application in detector base 805591!
Programmed with 5 standard languages: German, English, Spanish, French and Italian
802385.SV98
O2T/FSp multisensor detector IQ8Quad with composition of other l​anguages
1
Approval: VdS
O²T/FSp multisensor IQ8Quad with integrated flasher, sounder and speech
As 802385, but with an individual combination of national languages, see special order ​form in the
appendix.
When ordering, please note the “Ordering information for IQ8Quad and IQ8Alarm” and fill in ​“Order form
for individual combination of languages” printed in the appendix.
Cancellations or returns are not possible.
Not suitable for application in detector base 805591!
Programmed with an individual combination of up to 5 languages.
802385.SV99
O2T/FSp multisensor detector IQ8Quad, customized version
1
Approval: VdS
O²T/FSp multisensor IQ8Quad with integrated flasher, sounder and speech
As 802385, but with individual text and/or sounds. The max. recording time per device is ​169
seconds.
When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in ​“Order form
for individual combination of languages” printed in the appendix.
Costs for the recording of customer-specific texts and/or tones can be obtained by request.
Cancellations or returns are not possible.
Not suitable for application in detector base 805591!
Programmed according to customer specifications.
74
www.hls-austria.com
Automatic Detectors
802386
Series IQ8Quad (Intelligent Addressable)
1
O2T/Sp multisensor IQ8Quad
1
Approval: VdS
O²T/Sp multisensor IQ8Quad with integrated sounder and speech
2
In addition to smoke detection with conventional O²T multisensor technology, the detector ​is
provided with a built-in voice alarm device. It can be set to eight different levels.
Technical Data
Quiescent current @ 19 V DC
Load factor
Sound level
Detector specification
Specification
3
approx. 90 μA
3
max. 92 dB (A), +/- 2 db (A) @ 1m for DIN tone
EN 54-7/-5 B/-17, CEA 4021
EN 54-3 acoustic signaling device
EN 54-3 acoustic speech signaling device
4
5
Not suitable for application in detector base 805591!
Programmed with 5 standard languages: German, English, Spanish, French and Italian
6
802386.SV98
O2T/Sp multisensor IQ8Quad, special language
1
7
Approval: VdS
As 802386, but special language.
When ordering, please note the “Ordering information for IQ8Quad and IQ8Alarm” and fill in ​“Order form
for individual combination of languages” printed in the appendix.
8
Programmed with individual combination of up to 5 standard languages.
9
10
11
802386.SV99
O2T/Sp multisensor IQ8Quad, customized version
1
12
Approval: VdS
As 802386, but with individual text and/or sounds. The max. recording time per device is ​169
seconds.
13
When ordering, please note the “Ordering information for IQ8Quad and IQ8Alarm” and fill in ​“Order form
for individual combination of languages” printed in the appendix.
14
75
Automatic Detectors
Intrinsically Safe
Series IQ8Quad Ex (i)
117
62
Fire detector with base
Technical Data
Data according to ATEX:
Max. Input Voltage (Ui)
Max. Input current (Ii)
Max. Output current (Io)
Max. internal capacity (Ci)
Ambient temperature (Ta)
EC-type examination certificate
Ex-category
Explosion protection
Common technical data:
Operating voltage
Alarm current @ 9 V DC
Air speed
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
Dimensions
21 V DC
252 mA
10 mA
1 nF
-20 °C ... 70 °C
TÜV 09 ATEX 554910
II 2G (with Ex barrier Part No. 804744 or 764744)
Ex ib IIC T4 Gb
8 ... 42 V DC
typ. 18 mA
0 ... 25.4 m/s
-25 °C ... 75 °C
< 95 % (non-condensing)
IP 43 (incl. base + option)
ABS
white, similar to RAL 9010
approx. 110 g
Ø: 117 mm H: 49 mm (62 mm incl. base)
Detector bases are not supplied as standard.
Fully addressable devices for installation in hazardous areas with direct connection of the Ex ​
barrier (Part No. 804744) on the loop, without spending a loop address for the connection via ​
a transponder as in case of the conventional connection.
Additional detectors for the explosion zones can be found in the chapters manual call points ​
and special detectors. Detailed information about installation and operation can be found in ​
the documentation (Part No. 798920) on our website.
All of the following IQ8Quad intrinsically safe fire detectors must be operated with the Part ​
No. 805590 base. In the case of operation in standard zones, no individual addressing is ​
possible!
For usage in zone 1 and zone 2 in case of operation
- with individual addressing the Ex barrier Part No. 804744,
- in conventional zones the Ex barrier Part No. 764744 must be used!
The Ex barrier separates intrinsically safe and non-intrinsically safe circuits before the ​explosion prone area to be monitored (explosion zone).
Individual addressable operating
Zone 1
esserbus/esserbus-PLus
Ex area: IIC T2
Ex barrier (Part No. 804744)
Conventional operating
Zone 1
esserbus/esserbus-PLus
external power supply
Ex barrier (Part No. 764744)
Application example
76
www.hls-austria.com
Ex area: IIC T2
esserbus transponder 4 zone / 2 relay
Automatic Detectors
803271.EX
Intrinsically Safe
1
Rate-of-rise heat detector IQ8Quad Ex (i) w/o isolator
1
Approval: VdS, ATEX
Automatic heat detector with a single thermistor to sense the air temperature around the detector. ​
The fast semiconductor sensor for the reliable recognition of fires with a single thermistor to sense ​
the air temperature around the detector. The fast semiconductor quick rate of temperature rise as ​
well as integrated fixed temperature heat function for the recognition of fires with slow temperature ​
rise. Ideal for sensing in environments that are dirty or smoky under normal conditions, as well it is ​
unaffected by wind or atmospheric pressure.
Intelligent fire detector with decentralized intelligence, automatic function self-test, emergency ​
mode, storage of alarm and operating data, alarm display. Soft addressing and separate opera­
tional display is only possible when operating an esserbus / esserbus-PLus IQ8Quad detector ​
without loop isolator, especially for usage in explosion zones. Operation with individual addressing ​
at Ex barrier Part No. 804744 and as standard detector at Ex barrier Part No. 764744.
Technical Data
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
2
3
4
5
approx. 40 μA
max. 30 m²
max. 7.5 m
-20 °C ... 50 °C
EN 54-5 A1R : 2002
6
Special marking for heat detector on light pipe: black ring
7
Accessories
805590 Standard detector base for IQ8Quad
8
803371.EX
Optical smoke detector IQ8Quad Ex (i) w/o isolator
9
1
Approval: VdS, ATEX
Scattered-light smoke detector for reliable early recognition of fires. Responds well to slow-​burning,
smouldering fires. Intelligent fire detector with decentralized intelligence, automatic func­tion selftest, emergency mode, storage of alarm and operating data, alarm display. Soft ​addressing and
separate operational display is only possible when operating an esserbus / ​esserbus-PLus
IQ8Quad detector without loop isolator, especially for usage in explosion zones. ​Operation with
individual addressing at Ex barrier Part No. 804744 and as standard detector at Ex ​barrier Part No.
764744.
Technical Data
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
Declaration of Performance
10
11
approx. 50 μA
max. 110 m²
max. 12 m
-20 °C ... 70 °C
EN 54-7 : 2006
DoP-20914130701
12
13
Accessories
805590 Standard detector base for IQ8Quad
14
77
Automatic Detectors
803374.EX
Intrinsically Safe
O2T multisensor fire detector IQ8Quad Ex (i) w/o isolator
1
Approval: VdS, ATEX
Intelligent detector with two integrated optical smoke sensors with different scattered-light angles ​
as well as additional heat detector sensor evaluation for the recognition of smoldering fires up to ​
open fires with uniform characteristics. Comparison of the heat sensor signals for smoke classifica­
tion and reduction of false alarms by interferences, e.g. from steam or dust. Due to its excellent ​
detection characteristics, and enhanced false alarm management, the detector is also able to ​recognize TF1 and TF6 test fires, described in the standards. The O²T intelligent detector is also ​
suitable for a higher operating temperature of up to +65 °C. Used when early and reliable fire ​
detection is requested. Intelligent fire detector with decentralized intelligence, automatic function ​
self-test, emergency mode, storage of alarm and operating data, alarm display. Soft addressing ​
and separate operational display is only possible when operating an esserbus / esserbus-PLus ​
IQ8Quad detector without loop isolator, especially for usage in explosion zones. Operation with ​
individual addressing at Ex barrier Part No. 804744 and as standard detector at Ex barrier Part No. ​
764744.
Technical Data
Quiescent current @ 19 V DC
Area to be monitored
Height to be monitored
Application temperature
Detector specification
Declaration of Performance
approx. 60 μA
max. 110 m²
max. 12 m
-20 °C ... 65 °C
EN 54-7:2006 / -5B:2000 / A1:2002, CEA 4021
DoP-20915130701
Accessories
805590 Standard detector base for IQ8Quad
78
www.hls-austria.com
Automatic Detectors
Intrinsically Safe
Accessories for IQ8Quad EX (i)
1
804744
2
Ex barrier for intrinsic safe detectors Series IQ8Quad Ex (i)
1
Approval: ATEX
3
Ex barrier for the operation of intrinsically safe IQ8Quad Ex (i) series detectors directly on the ​
esserbus/esserbus PLus with individual addressing in connection with the detector base Part No. ​
805590.
Technical Data
Ambient temperature
Air humidity
Type of protection
Weight
Specification
Dimensions
4
-20 °C ... 60 °C
< 95 % (non-condensing)
IP 20
approx. 100 g
EN 54-18:2005
W: 20 mm H: 107 mm D: 115 mm
5
6
A safety barrier does not replace an overvoltage protection according to IEC 801, DIN VDE ​
0185 and 0855.
You can find more detailed information on the installation and the operation for IQ8Quad Ex ​
(i) Series detectors in the documentation Part No. 798920.
7
System requirements
8
- Number of detectors up to max. 10 fire detectors per Ex barrier
- Max. 4 Ex barriers per loop.
- At least one esserbus device with a isolator must be installed between two Ex barriers.
- Total loop length up to max. 3,500 m.
- For each Ex barrier the total loop length must be reduced about 200 meters.
- Cable length (spur) within the Ex area max. 400 m per Ex barrier.
- Load factor 3 per Ex barrier (Use load factor calculation tool).
9
10
Individual addressable operating
Zone 1
11
esserbus / esserbus-PLus
Ex area: IIC T2
12
Ex barrier (Part No. 804744)
Application example
13
14
79
Automatic Detectors
764744
Intrinsically Safe
Ex barrier for intrinsic safe detectors Series IQ8Quad Ex (i) and 9
​ 100
1
Approval: ATEX
Ex-barrier for the operation of intrinsically safe IQ8Quad Ex (i) series detectors in connection with ​
the detector base Part No. 805590 as well as the 9100 Ex (i) series in connection with the detector ​
base Part No. 781590.
Technical Data
Ambient temperature (Ta)
Air humidity
Dimensions
-20 °C ... 60 °C
< 95 % (non-condensing)
W: 12.5 mm H: 115 mm D: 110 mm
A safety barrier does not replace an overvoltage protection according to IEC 801,
DIN VDE 0185 and 0855. VdS approval is not required.
You can find more detailed information on the installation and the operation in the ​documentation Part No. 798920 for IQ8Quad Ex (i) series detectors and Part No. 798913 for ​9100 Ex
(i) series detectors.
System requirements
- Number of detectors up to max. 8 fire detectors per zone.
- Loop length per zone up to max. 300 m. (Total length measured from the terminals of the ​
detector zone).
Conventional operating
Zone 1
esserbus/esserbus-PLus
external power supply
Ex barier (Part No. 764744)
Ex area: IIC T2
esserbus transponder 4 zone/2 relay
Application example
764745
Isolation and assembly block for safety Ex barrier
1
For insulated (earth-free) mounting of Part No. 764744 Ex barrier onto standard hat rail.
Isolation block
Part No. 764745
Ex barrier
ground
Hatrail
80
www.hls-austria.com
Automatic Detectors
Intrinsically Safe
1
764752
Housing for Ex barrier
1
Polyester-housing for the installation of up to max. 10 Ex barriers with integrated inside mounting ​
rail. Also for operational application under extreme environmental conditions suitable.
Technical Data
Type of protection
Housing
Color
Dimensions
2
IP66
glass-fiber reinforced polyester
gray, similar to RAL 7000
W: 255 mm H: 250 mm D: 160 mm
3
Mounting material
4
Features
• Chemically resilient
• Temperature resilient
• Flame retardant
• Non-corrosive
• Sea water resistant
• Non-halogen, UV resistant
5
6
764754
Cable gland for housing 764752
1
Threaded cable connection for housing Part No. 764752.
Technical Data
Ambient temperature
Type of protection
Material
Color
Cable diameter
7
-20 °C ... 95 °C
IP66
Polyamide
blue, similar to RAL 9005
8 mm
8
9
10
11
12
13
14
81
Automatic Detectors
805590
Base Series IQ8Quad, ES Detect
Standard detector base for IQ8Quad
1
Technical Data
Connection terminal
Application temperature
Storage temperature
Material
Color
Weight
Dimensions
Ø 0.6 mm to 2 mm²
-20 °C ... 72 °C
-25 °C ... 75 °C
ABS
white, similar to RAL 9010
approx. 60 g
Ø: 117 mm H: 24 mm (incl. detector 62 mm)
Cable entry on the side or through the bottom plate.
Features
• A lot of space for wire connection
• Automatic closing of the loop bus wiring system ​
for detector extraction
• Detector extraction locking is enclosed in the ​
base
805591
Detector base with relay contact for IQ8Quad
1
IQ8Quad detector base with relay contact output. Contact: floating NO or NC contact selectable via ​
jumper. Settings on site: NO contact.
Features
• Provides a voltage-free contact controlled by the ​
remote output of a detector
• Draws negligible current
• A lot of space for wire connection
• Automatic closing of the loop bus wiring system ​
for detector extraction
• Detector extraction locking is enclosed in the ​
base
82
Wago clamps for looping in wires, e.g. type 243-204 (Ø 0.5 mm - Ø 1.0 mm) or 273-104 ​
(0.75 mm² - 2.5 mm²) can be mounted on the detector base.
www.hls-austria.com
Technical Data
Current consumption
Contact load relay
Connection terminal
Application temperature
Storage temperature
Air humidity
Material
Color
Weight
Dimensions
5 µA (w/o detector, active relay)
30 V DC/1 A
Ø 0.6 mm to 2 mm²
-20 °C ... 72 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
ABS
white, similar to RAL 9010
approx. 80 g
Ø: 117 mm H: 24 mm (incl. detector 62 mm)
Cable entry on the side or through the bottom plate. Connection of remote indicators not ​
allowed!
Wago clamps for looping in wires, e.g. type 243-204 (Ø 0.5 mm - 1.0 mm) or 273-104 (0.75 ​
mm²- 2.5 mm²) can be mounted on the detector base.
Not suitable for application with IQ8Quad with integrated alarm device Part No. 802383, ​
802384, 802385 and 802386 as well as 802385.SVxx and 802386.SVxx!
Automatic Detectors
Accessories
1
Accessories for Series IQ8Quad, ES Detect
805588
Detector cover for IQ8Quad w/o built-in alarm sounder
1
The cover plate protects the IQ8Quad detector against contamination during construction or renov­
ation works.
2
3
The detector covers can only be used for IQ8Quad fire detectors without built-in alarm ​
sounder! Application only for detector types with Part No: 802171, 802271, 802371, 802374, ​
802375 and 802473.
4
50 pcs
5
805587
Base cover for IQ8Quad
1
The cover plate protects the IQ8Quad detector base against contamination during construction or ​
renovation works.
6
50 pcs
7
805589
Detector cover for IQ8Quad with built-in alarm sounder
1
The cover plate protects the IQ8Quad detector against contamination during construction or renov­
ation works.
8
9
The detector covers can only be used for IQ8Quad fire detectors with built-in alarm sounder! ​
Application only for detector types with Part No: 802283, 802384, 802386 and 802385.
50 pcs
10
11
805571
Flush mount kit for base IQ8Quad
1
Adapter for installation in ceilings and for mounting the detector bases IQ8Quad (Part No. 805590 ​
and 805591) to the bottom side of false ceilings.
Technical Data
Application temperature
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
12
-20 °C ... 72 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
IP 40
ABS, plastic
white, similar to RAL 9010
approx. 165 g (with surface ring)
13
14
175 117
mm mm
140 mm
20 mm
3
mm
60
mm
45 mm
Application example
83
Automatic Detectors
805574
Accessories
4" trim ring and snap-in mounting clips for IQ8Quad detector b
​ ase
Snap-in mounting clips and trim ring for base installation, e.g. for installation on 4” electrical boxes. ​
Take note, the label plate Part No. 805576 is not applicable.
1
Technical Data
Material
Color
Dimensions
ABS plastic
white, similar to RAL 9010
Ø: 155 mm H: 19 mm (outside)
1 x Trim ring and 2 x snap-in mounting clips
Application example
805576
Label plate for detector base IQ8Quad
1
Before or after the installation of the detector, the label plate can be inserted at the side slot of the ​
IQ8Quad detector base.
For identification purposes the detector can be provided with the detector address and ​
detector zone for ceilings with a maximum height of 3 m.
A label can be attached to the inscription field. Blank labels can be marked when using a PC, ​
e.g. SIGEL Part No. LP725-white (58 x 18 mm) or other suppliers of writing materials.
There is a help file in the download area for creating the printing material.
Applicable for base 1x Part No. 805590/91 with 805570; for 805593.10, 805594.10.
Not to be used for base 1x Part No. 805590/91 in combination with 805571, 805572, 805573, ​
805574.
10 pcs
Application example
84
www.hls-austria.com
Automatic Detectors
Accessories
1
805577
Mounting adapter for intermediate ceilings
1
The mounting adapter is used for the quick and secure attachment of bases of the IQ8Quad ​
detector series, 9x00, IQ8Alarm and alarm signaling devices, parallel detector indicators, etc. to ​
suspended ceiling systems. It saves the usage of special hollow cavity fasteners, since the ​mounting screws of the bases are screwed directly into the slots of the mounting adapter. The ​mounting
adapter offers additional advantages in the fixing of the cables, rigid/flexible cable inlays ​and
threaded cable connections.
Technical Data
Material
2
3
ABS
4
10 pieces
Dimensions in mm
5
39.0
2.8 31.0
44.0
49.0
6
10.0
40.0
23.0
99.0
21.5
7
8
9
10
11
Application examples for fixing of the cables, rigid/flexible cable inlays and threaded cable ​connections
12
805570
IP43 protection for detector base IQ8Quad, flat design
1
For installation in environments with dust and humidity. The IP protection protects the IQ8Quad ​
detector base against dust and humidity. It increases the protection level to IP 43. For easy ​mounting to the base, the IP protection is provided with an adhesive film.
13
Technical Data
Type of protection
Material
Color
Dimensions
14
IP43
SBR/NR
white, similar to RAL 9010
Ø: 117 mm H: 3 mm
10 pcs
85
Automatic Detectors
805572.50
Accessories
IP43 damp room base adapter for IQ8Quad, ES Detect detector b
​ ase
The damp room socket adapter was designed specifically for the surface mounted cable feed ​
through cable protection pipes and has three breakthrough inputs for cable glands (optional). ​
Suitable for IQ8Quad and ES Detect detector base.
1
Technical Data
Type of protection
Material
Color
IP43
ABS
white, similar to RAL 9010
Please follow the installation instructions on the adapter!
Substitute for Part No. 805572
Cable glands (Part No. 704147, 704148) are not included.
6,0
59,6
59,6
6,0
15,8
5,4 ø
46,0
119,3
111,4
119,3
Application example (labeling field and cable glands optional)
805573
IP43 protection for detector base IQ8Quad, deep design
1
Same as 805570, but as universal protection. Additionally, the seal prevents humidity from entering ​
at the sides.
Technical Data
Type of protection
Material
Color
5 pcs
86
www.hls-austria.com
IP43
rubber
white, similar to RAL 9010
Automatic Detectors
Accessories
805560
EMV isolator for IQ8Quad, ES Detect detector base
1
1
In fire alarm systems where a high electromagnetic interference/EMI load (e.g. by fluorescent ​
lamps or electrical control devices) must be expected it is recommended to mount the EMI-Module ​
in the standard detector base (Part No. 805590) of the corresponding fire alarm detectors.
2
The EMI-Module must only be operated in conjunction with standard IQ8Quad detector base ​
(without relay board) and only for detectors without integrated alarm devices (Part No. ​
802382 to 802386, incl. adapted variants).
3
10 pcs
4
5
Application example
6
781482
Kit for suspended installation
1
Kit for detector bases (Part No. 781590, 805590 and 805591) for suspended installation with ​
pendulum stabilizer, cable entry at the top, pull relief by means of PG cable entry including junction ​
box with terminals. The detector height can be adjusted individually depending on the cable length ​
to bridge over the heat cushion below the ceiling.
Technical Data
Material
Installation
Color
Dimensions
7
8
ABS plastic
attached to the zone cable
white, similar to RAL 9010
Ø: 84 mm H: 15 mm (aluminum-stabilizer)
9
It is not possible to use telescopic rods.
Not suitable for series 3000.
10
As shown in the left picture
11
Heat cushion: Smoke-free area
12
Filled with smoke:
Detection guaranteed
13
14
6-pole terminal
inside
Cable entry with cord grip
Standard detector cable
Gap between screws suitable
for detector series
78xxxx and 80xxxx
Detector base can be equipped with
IP protection 805570 or 805573
87
Automatic Detectors
Accessories
781550
Protective cage
1
Protective cage for detectors
Steel basket for protection from damage and also unauthorized disconnection of the detector.
Technical Data
Material
Color
Dimensions
steel with paint coating
white, similar to RAL 9010
Ø: 140 mm H: 115 mm
Can be used with all bases, IP43 moisture-proof adapter, also for wireless base and wireless ​
gateway.
Application example with IQ8Wireless detector base and IQ8Alarm
850054
Special painting IQ8Quad detector base
The IQ8 detector base is painted and delivered according to the required RAL color.
For identical colors, we suggest to order a suitable number for serial purposes.
When ordering please specify:
- RAL code
- Glossy, semi-matt, matt finishing
850055
Special painting IQ8Quad
As 850054, but for automatic detectors of the IQ8Quad series.
88
www.hls-austria.com
Automatic Detectors
Accessories
1
Testquipment for Several Detector Series
805580
Detector removal tool
2
1
It is suitable for removing series 9x00 as well as IQ8Quad detectors. Through optional adaptation ​
of the suction cup to the corresponding insert on the detector removal tool, the IQ8Quad detector ​
covers (Part No. 805588 and 805589) and the base covers for IQ8Quad (Part No. 805587) can be ​
attached as well as removed. The detector removal tool can be adapted to the telescope rod Part ​
No. 060426 and 060427 as well as with Part No. 805581 to 769813.
3
4
Snap on detector removal tool, then spin clockwise and remove the detector.
5
6
7
8
9
10
11
Application example
12
805581
Adapter for pole 769813
1
The adapter for the pole (Part No. 769813) is designed for attaching the Part No. 805580 detector ​
removal tool and the Part No. 805582 smoke detector tester.
13
14
060426
Plastic telescopic extension
1
Telescopic extension for plastic telescopic rod (Part No. 060427). Up to 3 telescopic extensions ​
can be attached to the telescopic rod. The maximum height that can be reached is increased to 9 ​
m.
Technical Data
Material
Length
Fiberglass
1.13 m
Features
• Easy aid for daily maintenance of high ceilings
• Stable construction
• Important for attaching and releasing detectors
• Extremely high level of flexural strength due to ​
fiber-plastic composite material
• Totalock TM for easy and secure locking
89
Automatic Detectors
Accessories
060427
Plastic telescopic rod
1
Extendable detector pull-down pole made of glass-fiber reinforced plastic for adapting the Part No. ​
805580 detector removal tool as well as testers with Part No. 060429 and 805582.
Technical Data
Material
Length
Fiberglass
4.5 m
Features
• Length of 1.26 m in retracted state
• 4 segments, lockable
805586
Carrying bag for test equipment
1
The carrying bag has many pockets and compartments in which the ESSER smoke alarm testers, ​
test gas bottles, all cables and other maintenance accessories can be stored. So everything you ​
need for maintenance can always be found in one place. The upholstered, adjustable shoulder ​
strap ensures very easy and comfortable transport. An additional advantage: the bag protects ​
equipment from dirt and moisture.
Technical Data
Dimensions
W: 480 mm H: 420 mm D: 260 mm (carrying bag)
1 x Carrying bag and 1 x cover for telescopic rods/extensions
Features
• Exterior lid with Velcro fastening transportation ​
straps for telescopic rod and extensions
• Inside lid with 2 storage compartments for ​
battery backs Part No. 060431
• Inside compartment with up to three optional ​
dividers
• Big front pocket, with up to two optional dividers
• Wide shoulder strap with sliding shoulder pad ​
and additional handles
• Cover with carrying strap for up to 4 telescopic ​
rods Part No. 060427 and/or extensions 060426
Capacity of the
protective
carrying bag:
2 x Battery baton
3 x Smoke detector tester
Front pocket for charger,
test gas, etc.
Capacity of the carrying bag
90
www.hls-austria.com
Up to 4 telescopic rods
in a special cover
1 x Telescopic rod
Automatic Detectors
Accessories
1
805551
Multi-stimulus detector tester TF 2001
1
Detector tester kit Testifire 2001 for the functional testing of point-type fire detectors with various ​
sensors. The activating stimuli for smoke, heat and CO (carbon monoxide) are generated in this ​
testing unit. Thus the changing of test tools for different types of detectors is no longer necessary.
All fire detector types can be tested with only one test instrument. The test tool is suitable for all ​
optical smoke detectors, ionization detectors, CO detectors and heat detectors. It facilitates fast ​
and effective testing of single and intelligent multisensor fire detectors. So testing of the different ​
sensors can be carried out one after another or for all at the same time.
The required stimuli are generated on demand at the time of test from the corresponding capsule ​
(smoke or CO). Pressurized gas cans are no longer being used.
The selection of the testing stimuli, as well as their combination and sequence are menu driven via ​
keypad and are represented on the display (multilingual). So e.g. simultaneous or sequential ​
testing, or also a combination thereof, can be easily programmed and then carried out at the ​
detector. The activation of the testing device occurs automatically, as soon as the detector inter­
rupts the light barrier integrated in the device. If necessary, a clearing phase can be chosen ​
between the specific testing criteria that enables the stimuli to be blown out of the detector immedi­
ately for the next test by the integrated ventilator.
The currently active criterion is represented by a multi-colored LED indicator and is clearly recog­
nizable even from large distances. The fill-level of the respective test resource capsules can be ​
shown in the display. Warnings are indicated automatically e.g. if a capsule is nearly empty. The ​
capsules offer much higher test capacities in comparison with aerosol cans.
The power supply of the testing head occurs via Ni-MH batteries (metal hydride batteries) in the ​
adapter between testing head and telescopic rod. Charging of the battery occurs with the charger ​
optionally via adapter (100-230 V AC) or via 12 V DC input (vehicle cigarette lighter).
Suitable for IQ8Quad and 9x00 detector series.
Features
• Generation of smoke, heat and CO in a single ​
test unit
• Clearing cycle of the detector via integrated ​
ventilator for better reset
• Simultaneous or sequential testing with various ​
stimuli
• Suitable for single and multi-criteria fire ​detectors
• Suitable for smoke-, heat- and gas- (CO) ​detectors
• Targeted heat rays provide fast activation of ​
heat sensors (up to 90°C/194°F, and/or a​ djustable up to 100°C/212°F)
• Test activation via infrared barrier, no mechan­
ical triggering, no ceiling contact necessary
• Easy, fast and efficient testing, as changing of ​
testing device is not necessary
• Multilingual and user-friendly menu control: ​
English, German, Spanish, French, Italian, ​
Dutch, Swedish
• Battery operated portable device
• Environmentally friendly and safe through usage ​
of test cartridges instead of test gas cans
Technical Data
Battery charging
Heat detector response threshold
Ambient temperature
Storage temperature
Air humidity
2
3
4
5
6
7
8
75-90 minutes
up to 90°C adjustable up to 100°C
5 °C ... 45 °C
-10 °C ... 50 °C
< 85 % (non-condensing)
9
Detector tester kit Testifire 2001 consists of:
Testing head, smoke capsule, CO capsule, 2 Ni-MH battery packs, charger
10
Accessories
805552 Smoke capsule for multi-stimulus detector tester 805550/51
805553 CO capsule for multi-stimulus detector tester 805551 (Testifire TC3)
060426 Plastic telescopic extension
060427 Plastic telescopic rod
060431 Spare battery baton
Smoke
Heat
CO
Menu
Status
Example of testing
with only one stimuli
Smoke 1
Heat 2
CO 3
Menu
Status
Example of sequential
testing (all criteria
successively)
11
12
Smoke 1
Heat 1
CO
Menu
13
Status
Example of a
simultaneous testing
(smoke + heat at the
same time)
14
Smoke 1
Heat 1
CO 2
Menu
Status
Example of
combination of
simultaneous and
sequential testing)
Selection of different test criteria displayed
91
Automatic Detectors
Accessories
805550
Multi-stimulus detector tester TF 1001
Features
Same as 805551, but for testing of detectors with smoke and heat sensors. For testing CO ​
consider multi-stimulus detector tester TF 2001 (Part No. 805551).
• Creation of smoke and heat with one single test ​
device
• Desmoking of detector via an integrated fan for ​
fast resetting
• Simultaneous or successive testing with ​different activating materials
• Suitable for single and multi-criteria detectors
• Suitable for smoke and heat detectors
• Targeted heat radiation facilitates quick activa­
tion of the thermal sensors (up to 90°C/194°F ​
and/or can be switched up to 100°C/212°F)
• Test activation through infrared barrier, no ​
mechanical triggering, ceiling contact not neces­
sary
• Quick, easy and efficient testing since there is ​
no need to exchange test device
• Multilingual and user-friendly menu
• Portable battery-powered device
• Environmentally friendly and safe through usage ​
of test cartridges instead of test gas cans
Technical Data
Battery charging
Heat detector response threshold
Application temperature
Storage temperature
Air humidity
75-90 minutes
up to 90°C adjustable up to 100°C
5 °C ... 45 °C
-10 °C ... 50 °C
< 85 % (non-condensing)
Detector tester kit TF 1001 consists of:
Testing head, smoke capsule, 2 Ni-MH battery packs, charger
Accessories
805552 Smoke capsule for multi-stimulus detector tester 805550/51
060426 Plastic telescopic extension
060427 Plastic telescopic rod
060431 Spare battery baton
Smoke
Heat
CO
Menu
Status
Example of testing
with only one stimuli
Smoke 1
Heat 1
CO
Menu
Example of a
simultaneous testing
(smoke + heat at the
same time)
Smoke 1
Heat 2
CO 3
Menu
Status
Example of sequential
testing (all criteria
successively)
Status
Smoke 1
Heat 1
CO 2
Menu
Status
Example of
combination of
simultaneous and
sequential testing)
Selection of different test criteria displayed
805552
Smoke capsule for multi-stimulus detector tester 805550/51
1
Replacement smoke capsule (Testifire TS3) for the testing of smoke detectors series IQ8Quad and ​
9x00 with optical and/or ionization sensors. Suitable for the multi-stimulus detector tester Part No. ​
805550/51.
Features
• Non-flammable, non-toxic materials
• Production of test gas only during the testing
• Does not cause any residue in the sensor ​
chamber
• Suitable for optical and ionization detectors
• No test gas storage under pressure – no ​dangerous goods
• More productivity than the spray can
92
www.hls-austria.com
Automatic Detectors
Accessories
805553
CO capsule for multi-stimulus detector tester 805551
1
1
Replacement CO capsule (Testifire TC3) for the testing of detectors with carbon monoxide sensors ​
(CO). Especially suited for the OTG multisensor fire detector (CO) IQ8Quad with isolator (Part No. ​
802473). Suitable for the multi-stimulus detector tester Part No. 805551.
2
Features
• Non-flammable CO activating material
• Generation of small amounts of CO
• Generation of CO during testing only
• No storing of pressurized CO - no dangerous ​
goods
• More productivity than the spray can
The OTG multisensor fire detector (CO) IQ8Quad with isolator (Part No. 802473) is generally ​
tested either
-with the test gas Part No. 060430.10, suitable for the smoke detector tester Part No. ​
805582, or
-with Part No. 805552, suitable for the multi-stimulus detector tester Part No. 805551.
3
The Part No. 802473 is VdS-approved as a smoke detector, the CO test gas is required for ​
the additional triggering of the electrochemical CO gas cell.
4
5
805582
Smoke detector tester
6
1
The smoke detector tester is designed for electric function control for the IQ8Quad and series 9x00 ​
detectors. After an aerosol has been released, the operation capacity of the measuring chamber ​
can be tested by using the transceiver. The smoke detector tester is adapted to the rod (Part No. ​
060427).
7
The telescopic rod is not supplied as standard.
8
Accessories
060426 Plastic telescopic extension
060427 Plastic telescopic rod
9
805583
CO test gas for smoke detector tester 805582
1
Test gas for testing carbon monoxide CO-detectors. Specifically designed for the OTG multisensor ​
fire detector (CO) IQ8Quad with isolator (Part No. 802473), suitable for smoke detector tester Part ​
No. 805582.
Technical Data
Content
10
11
250 ml (per bottle)
12
The OTG multisensor fire detector (CO) IQ8Quad with isolator (Part No. 802473) should only ​
be tested in connection with test gas Part No. 060430.10 suitable for smoke detector tester ​
Part No. 805582. Detector Part No. 802473 has been approved as smoke detector by VdS ​
and the CO test gas is used to additionally trigger the electrochemical CO-gas cell.
Please take note that this item has to be handled as dangerous goods (aerosols, non-​flammable, UN1950)
13
14
805584
Test gas for smoke detector tester 805582
For all IQ8Quad, ES Detect and series 9x00 detectors, suitable for smoke detector tester 805582.
1
Technical Data
Content
250 ml (per bottle)
Also suitable for ionization detector of the 9000, 9100 and 9200 series.
These are considered dangerous goods (aerosols/gases, flammable, UN1950).
Substitute for Item No. 060430.10
93
Automatic Detectors
805585
Accessories
Smokesabre test gas for smoke detectors
Smokesabre is a test gas and manual testing device in one. The test gas is passed through the ​
extensible pipe, which also serves to increase the range for the detector. Facilitates the triggering ​
of smoke alarms in confined spaces, such as false ceilings/floors and is also applicable to low ​
ceiling heights.
Suitable for all detectors of the series IQ8Quad, ES Detect, 9x00 and smoke extraction systems.
1
Technical Data
Content
Dimensions
150 ml (per bottle)
L: 193 mm
L: 335 mm (with pulled-pipe)
Also suitable for ionization detector of the 9000, 9100 and 9200 series. These are considered ​
dangerous goods (aerosols/gases, flammable, UN1950).
12 pieces
Application example
94
www.hls-austria.com
Automatic Detectors
060429
Accessories
1
Test head for heat detector together with battery and charger
1
Technical Data
Battery charging
Ambient temperature
Storage temperature
Air humidity
75-90 minutes (if completely discharged)
5 °C ... 45 °C
-10 °C ... 50 °C
< 85 % (non-condensing)
2
3
Test head, 2 battery batons, charger
Features
• Mains cable is not required for testing
• Power supply with rechargeable NiMH battery in ​
the adapter of the telescopic rod
• Time based termination of testing after 120 ​
seconds in order to prevent any heat-related ​
damages of the detectors
• Detector head is switched off after not being ​
used for 5 minutes
• Adjustable inclination angle of detector head for ​
an optimal orientation towards the object which ​
has to be tested
• Testing height up to 6 meters with telescopic rod ​
and up to 9 meters with its extension device
• Excess-current protection for the battery
• Display of operating status of the detector head ​
with Duo-LED (red/green)
• Battery can be charged via mains supply or via ​
cigarette lighter in vehicles
Accessories
060426 Telescopic extension
060427 Plastic telescopic rod
060431 Spare battery baton
4
5
6
7
8
9
060431
Spare battery baton
1
Replacement battery pack (NiMH) for test head Part No. 060429 and 805551.
10
11
12
769080
Smoke pellets for testing purposes
1
Pellets for the generation of dense bright smoke. To charge detectors with smoke for testing ​
purposes and verification of air flow. The pellets are lit with an open flame (e.g. matches, lighter ​
etc.). Extinguishing is not necessary. Please ensure the use of a non-flammable base. After igni­tion
the pellet will burn to complete ash (without formation of flames).
13
14
Without oil
6 pcs. smoke pellets
Features
• 40 sec. burning-time per smoke pellet
• 18 m³ smoke produced per smoke pellet
95
Notes
96
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
11
Manual Call Points
Large Design (ABS)
Large Design (Aluminum)
98-101 12
102-103
Accessories for MCP large design
104-107
Small Design (ABS)
108-114
Accessories for MCP small design
115-116
Special Design
117-122 14
97
13
Manual Call Points
Large Design (ABS)
1
133
36
133
Features
• Slimline design
• Low power consumption
• Plug-in connection clamps
• Optional terminal clamps
• 2 x cable entries on top, at the bottom and on ​
the rear panel
• Fixing on standard flush mounted installation ​
box
• Test function via manual call point service key
• Detectors that are not ready for operation can ​
be marked with the "Out of order" label by ​reversing the enclosed operating front foil
The advanced generation of manual call points with fragile elements meets the latest multicultural ​
requirements of the EN 54 - 11 standards as type B (double action). The elegant detector housing, ​
available in 5 different RAL colors, is provided with a pictogram, which is easy to comprehend for ​
foreign people, illiterates as well as children.
Depending on individual requirements, optional labeling foils can be used which can easily replace ​
the pictogram without special tools. The triggering element is protected by a pane of glass and is ​
indicated by arrows.
If required, optional labeling foils can be used, which can easily replace the pictogram. The trig­
gering element is protected by a glass pane and is indicated by arrows. The innovative manual call ​
points can be tested by using the service key to activate the triggering mechanism, which is hidden ​
by a faceplate. Clever design structures allow easy installation.
The manual call points consist of a housing and an electronic module, each of the two parts must ​
be ordered separately.
Type B definition - double action in accordance with EN 54-11 § 3.4.2
(Excerpt taken from EN standard):
Manual fire alarm unit, for which the alarm status cannot be set until an alarm is additionally ​
triggered by the user after the fragile element has been broken or its position, has been ​
changed.
Take note, for a LARGE MCP you have to order the electronic module and the MCP housing ​
separately to have a complete MCP.
Not all possible combinations of electronic modules and housings are approved by VdS. ​
When using the manual call point as a fire detector for manual actuation in compliance with ​
the EN 54-11 standards, a red housing together with the provided pictogram must be used. ​
When using the manual call point in heat exhaust or extinguishing system areas, the ​appropriate housing color must be chosen in compliance with the correct standards.
Wago clamps for looping in wires, e.g. type 273-100 (0.5 mm² - 1.5 mm²) or 273-104 ​
(0.75 mm² - 2.5 mm²) can be mounted on the detector base.
MCP out of order
Application example
98
www.hls-austria.com
Easy to maintain the change of condition
by turning the operating foil
MCP ready for use
Manual Call Points
Large Design (ABS)
1
Plastic Housings
Housings for electronic module 80490x.
1
Technical Data
Type of protection
Housing
Installation
Weight
Dimensions
2
IP 44
ASA plastic
surface mount
approx. 83 g (w/o electronic module)
W: 133 mm H: 133 mm D: 36 mm
3
Housing with glass pane (Part No. 704910)
Plastic key (Part No. 769910)
4
Accessories
704910 Spare glass for manual call points
769910 Plastic spare key
769911 Metal key for large MCP
769916 Service key
704917 Option IP 55 shrink sleeve for large MCP 80490x
704911 Universal foil for large MCP housing ABS
704900
5
6
MCP housing large with glass pane, red, similar to RAL 3020
7
Technical Data
Dimensions
8
W: 133 mm H: 133 mm D: 36 mm
The red manual call point housing is only available with the pictogram (as shown) in ​compliance with EN 54-11.
Please note that in compliance with EN54-11 the labeling must come with the burning house ​
symbol.
9
Pictogram according to EN54-11
704901
10
MCP housing large with glass pane, blue, similar to RAL 5015
The Part No. 804902 electronic module in a blue housing complies with the EN 12094-3 and ​
thus can be applied as an electronic stop button for gas extinguishing systems in dry, non-​
hazardous production sites.
For different use such as application as "HOUSE ALARM" push button, ready-made labels ​
are provided.
11
12
Labeling foil set (white) for various international applications.
704902
13
MCP housing large with glass pane, yellow, similar to RAL 1021
14
The Part No. 804900 or 804901 electronic module in a yellow housing 704902 complies with ​
the EN 12094-3 and thus can be applied as electronic control module for gas extinguishing ​
systems in dry, non-hazardous production sites.
For different use such as application as "HOUSE ALARM" push button, ready-made labels ​
are available.
Labeling foil set (black) for various international applications.
704903
MCP housing large with glass pane, orange, similar to RAL 2011
Labeling foil set (black) for various international applications.
704904
MCP housing large with glass pane, green, similar to RAL 6002
Labeling foil set (white) for various international applications.
99
Manual Call Points
Large Design (ABS)
Electronic Modules - Conventional
1
Technical Data
Operating voltage
Alarm current @ 9 V DC
No. of detector/zone
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Housing
Weight
Detector specification
Dimensions
804900
8 ... 30 V DC
typ. 9 mA
10 detectors per zone (according to VdS)
LED, red
max. 2.5 mm² (AWG 26-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP44 (in housing), IP55 (with accessory)
PC ASA plastic
approx. 236 g (with housing)
EN 54-11, Type B
W: 133 mm H: 133 mm D: 36 mm
Conventional MCP electronic module
1
Approval: VdS, CNBOP
With alarm indicator, suitable for connection to a standard detector zone.
Technical Data
Declaration of Performance
DoP-20482130701
In combination with the yellow housing (Part No. 704902), the electronic module is approved ​
as an electronic control unit for gas extinguishing systems.
The Part No. 804900 electronic module with yellow housing conforms to the EN 12094-3 ​
standard and can be used as an electronic control unit for gas extinguishing systems in dry, ​
non-hazardous industrial premises.
804901
Conventional MCP electronic module with 2nd microswitch
1
Approval: VdS, CNBOP
Same as 804900, but with second microswitch with dry contact NC/C (break) or NO/C (make) that ​
is activated when the alarm is triggered.
Technical Data
Contact load
Declaration of Performance
30 V DC / 1 A
DoP-20482130701
In combination with the yellow housing (Part No. 704902), the electronic module is approved ​
as an electronic control unit for gas extinguishing systems.
The Part No. 804901 electronic module with yellow housing conforms to the EN 12094-3 ​
standard and can be used as an electronic control unit for gas extinguishing systems in dry, ​
non-hazardous industrial premises.
804902
Conventional MCP electronic module w/o snap-on function
1
Approval: VdS with blue housing 704901
Same as 804900, but without snap-on function.
Technical Data
Declaration of Performance
DoP-20195130701
This electronic module is only approved as an electric stop push-button for gas extinguishing ​
systems when combined with the blue housing (Part No. 704901). The electronic module ​
Part No. 804902 with blue housing complies with the EN 12094-3 standard and therefore it ​
can be used as an electric stop push-button for gas extinguishing systems in dry, non-​hazardous branches.
In case the manual call point is used as a "house alarm" push-button, pre-printed labels are ​
provided in the manual call point package.
100
www.hls-austria.com
Manual Call Points
Large Design (ABS)
1
Electronic Modules for Series IQ8MCP - Addressable
1
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Alarm current w/o communication curtain
No. of detector/zone
Operation indicator
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Housing
Weight
Detector specification
Dimensions
8 ... 42 V DC
approx. 45 μA
approx. 18 mA
10 detectors per zone, 127 detectors/loop (according ​
to VdS)
LED, green
LED, red
max. 2.5 mm² (AWG 26-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP 44 (in housing), IP 55 (with accessory)
PC ASA plastic
approx. 236 g (in housing)
EN 54-11, type B
W: 133 mm H: 133 mm D: 36 mm
2
3
4
5
6
804905
IQ8MCP electronic module with isolator
1
Approval: VdS, CNBOP
7
Addressable electronic module suitable for use in the esserbus and powered loop with alarm latch ​
and alarm indicator. Optional connection for conventional MCP. Without BUS connection, the ​
detector operates as conventional MCP. Built-in loop isolator in the manual call point. An external ​
detector zone (D-line) could be connected with up to ten conventional manual call points (internal ​
Alarm resistor for each detector 1 KOhm) - e.g. Part No. 804900 or 804901 to this IQ8 manual call ​
point model and configure required operation with tools 8000. When an alarm is triggered the ​
address and the programmed additional text of the MCP IQ8 to which the conventional zone is ​
connected are displayed automatically. Cable length of the D-line max. 500 meters!
Technical Data
Type of protection
Detector specification
Declaration of Performance
8
9
IP44 (in housing), IP55 (with accessory)
EN 54-11, typ B
DoP-20489130701
10
11
804906
IQ8MCP electronic module w/o isolator, with relay
1
Approval: VdS
12
Addressable electronic module with floating contacts of a changeover relay NC/C (break) or NO/C ​
(make), suitable for use in the esserbus and powered loop with alarm latch and alarm indicator. ​
Without BUS connection, the detector operates as conventional MCP.
Without built-in loop isolator and optional connection for conventional MCP.
13
The relay output is activated with the triggering of this detector. The relay output can be ​
programmed in the System 8000 and IQ8Control FACP customer data as a control group.
Technical Data
Contact load relay
Declaration of Performance
14
30 V DC / 1 A
DoP-20488130701
101
Manual Call Points
Large Design (Aluminum)
Both housing and electronic module need to be ordered. Not all possible combinations of ​
electronic modules and housings are approved by VdS. The approved combinations are ​
listed in the VdS approval field for the corresponding electronic module.
Aluminum Die-Cast Housings
1
Technical Data
Type of protection
Material
Installation
Weight
Dimensions
IP43, IP54 with kit 704070
aluminum, die-cast
surface mount
approx. 600 g
W: 126 mm H: 126 mm D: 42 mm
Housing with glass pane and plastic key, fixing material, 1 x multilingual "Out of order" paper insert, 2 x ​
cable entries, 2 x dummy plugs
Accessories
704910 Spare glass for manual call points
769910 Plastic spare key
769911 Metal key for large MCP 80490x
704801.10
MCP housing ALU, large, glass pane
1
Printed with pictograms in accordance with EN 54-11.
Technical Data
Color
704804
MCP housing with glass, print: house alarm
Technical Data
Color
704854
red, similar to RAL 3000
red, similar to RAL 3000
MCP housing with glass, print: house alarm
Technical Data
Color
blue, similar to RAL 5009
Neutral Housings w/o Print
1
704870
MCP housing ALU, large, neutral
1
Technical Data
Color
102
www.hls-austria.com
yellow, similar to RAL 1018
Manual Call Points
Large Design (Aluminum)
1
Electronic Modules for Series 9000
2
704477.10
Conventional MCP electronic module with 2nd micro-switch, S
​ eries 9000
1
Approval: VdS with housing 704801.10
3
Printed with pictograms in accordance with EN 54-11
Technical Data
Operating voltage
Alarm current @ 9 V DC
Contact load
No. of detector/zone
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Weight
Detector specification
Dimensions
Declaration of Performance
4
8 ... 30 V DC
typ. 9 mA
30 V DC/1A
10 detectors per zone (according to VdS)
LED, red
0.6 ... 1.5 mm²
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP43 (with housing)
IP 54 (with housing and option 704070)
approx. 100 g (w/o housing)
EN 54-11, type B
W: 95 mm H: 95 mm D: 25 mm
DoP-20478130701
5
6
7
8
Electronic Module for Series 9200
9
804473.10
Addressable MCP electronic module with zone isolator, Series 9
​ 200
10
1
Approval: VdS with housing 704801.10
Printed with pictograms in accordance with EN 54-11
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Alarm current @ 9 V DC
Alarm current w/o communication curtain
Contact load
No. of detector/zone
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Weight
Detector specification
Dimensions
Declaration of Performance
11
8 ... 42 V DC
approx. 45 μA
typ. 9 mA
approx. 18 mA
30 V DC/1A
10/zone, 127/loop (VdS)
LED, red
0.6 mm ... 1.5 mm²
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP43 (with housing)
IP 54 (with housing and option 704070)
approx. 100 g (w/o housing)
EN 54-11, type B
W: 95 mm H: 95 mm D: 25 mm
DoP-20481130701
12
13
14
103
Manual Call Points
Accessories for MCP large design
704910
Spare glass pane for MCP housing 70490x, 7048xx und 761694
1
Spare glass pane for detector housings large design Part No. 70490x, 7048xx, 761694 and ​
761697 in compliance with EN 54-11.
Technical Data
Dimensions
W: 80 mm H: 80 mm
10 pcs
701040
Spare glass pane red for MCP housings 7047xx and 7048xx
1
Spare glass pane, printed with red circle segments (similar to RAL 3000) for all Part No. 7047xx ​
and Part No. 7048xx manual call points (large design).
Technical Data
Dimensions
W: 80 mm H: 80 mm
10 Multilingual "Out of order" paper labels are included.
10 pcs
769921
"Out of order" sign, multilingual for 7047xx, 7048xx and 70490x
1
Plastic sign for all Part No. 7047xx, 7048xx and 70490x manual call points (large design).
Technical Data
Dimensions
W: 80 mm H: 80 mm
704915
Operating foil for large MCP 80490x, neutral
1
Replacement operating panel foil, neutral without logo, for large design Part No. 80490x manual ​
call points in resistant plastic design. The foil is designed as a double-sided insert. Complementing ​
the standards-compliant symbolism for manual fire alarms according to EN 54-11 (type B), it ​contains a symbol on the back for the removal from service of the alarm and is easily accessible at ​all
times for possible maintenance operations.The "Out of order" representation occurs via an inter­
nationally understandable construction worker symbol and multilingual text.
Technical Data
Material
Dimensions
PP (0.3 mm)
W: 72 mm H: 75.7 mm
10 pcs.
MCP “Out of order”
Application example
104
www.hls-austria.com
Easy to maintain the change of condition
by turning the operating foil.
MCP “Ready for use”
Manual Call Points
Accessories for MCP large design
1
704917
Option IP55 shrink sleeve for large MCP 80490x
1
10 shrink sleeves for clamp terminals to increase protection class to IP55.
10 pcs
2
3
4
5
6
IP44
IP55
7
Application example without (IP44) and with (IP55) shrink sleeve
8
704911
Front foil with universal text for large MCP ABS, white lettering
1
AMOK-ALARM
Emergency Stop
Gas extinguishing system
Arrêt d'urgence
Transparent foil with white lettering.
Système d'extinction à gaz
PARO EMERGENCIA PARAGEM EMERGÊNCIA
Sistema de extinción
Sistema de extinção
BLUSSING BLOKKEREN
Knop ingedrukt houden
9
Universal, punched foil set (transparent with white imprint) for the labeling field, different from the ​
standard version.
POZAR
10
10 pcs
11
similar image
704912
Foil for front face with universal text for large MCP ABS, black l​ettering
12
1
As 704911, but with black imprint.
10 pcs
13
14
704070
IP54 kit for large MCP 7048xx
1
Cable entries to increase protection class from IP 43 to IP 54 for manual call points in die-cast ​
aluminum housings (Part No. 7048xx).
Technical Data
Material
Color
Cable diameter
PS
gray, similar to RAL 7035
6 mm
as shown
105
Manual Call Points
Accessories for MCP large design
769910
Plastic key for large MCP
1
Plastic key type D for all manual call points (large design).
Please note that for activating the test functionality of electronic modules (Part No. 80490x), ​
the service key Part No. 769916 is required.
769911
Metal key for large MCP
1
Metal key type D for all detector housings (large design).
Please note that for activating the test functionality of electronic modules (Part No. 80490x), ​
the service key Part No. 769916 is required.
769916
Service key for electronic module (Part No. 80490x)
1
With this metal service key, the test functionality of the manual call point is activated and reset by ​
authorized persons only.
The key is suitable for all electronic modules with Part No. 80490x from index 05 and yellow ​
locking.
781682
Weather protective cover for MCP housings 7047/48xx, red
1
Protective housing with protruding roof edge, for all Part No. 7047xx and 7048xx detector housings ​
for increased mechanical protection as well as for protection from bad weather conditions.
Technical Data
Material
Color
Dimensions
PVC
red, similar to RAL 3000
W: 135 mm H: 153 mm D: 62 mm
Please mention for the manual call point, large design plastic (e.g. IQ8MCP), the protection ​
cover Part No. 781693 and the related accessories.
Weather protective cover and mounting material
781692
Weather protective cover for MCP housings 7047/48xx, blue
1
Same as 781682, but blue color.
Technical Data
Color
blue, similar to RAL 5009
Weather protective cover and mounting material
106
www.hls-austria.com
Manual Call Points
781693
Accessories for MCP large design
1
Protective cover for manual call points, German
1
Technical Data
Ambient temperature
Type of protection
Material
Weight
Dimensions
Features
• Easy to install
-40 °C ... 49 °C
IP 44
Polycarbonate
approx. 590 g
W: 180 mm H: 260 mm D: 100 mm
2
3
This protective cover prevents false alarms, without hampering real alarms. This device ​
consists of a rack and a lid, made of transparent polycarbonate.
It prevents inadvertent activation, vandalism, dust and water from triggering false alarms. The ​
protective cover is suitable for all manual call points.
4
Accessory for installation
5
6
7
Application example
8
781694
Protective cover for manual call points, English
Same as 781693, but English.
9
781698
Surface spacer for protective cover
1
The spacer is required for surface mount wiring.
10
Technical Data
Weight
Dimensions
11
approx. 510 g
W: 180 mm H: 260 mm D: 50 mm
Accessory for installation
12
781699
IP55 kit for protective cover
1
Mounting kit - self-adhesive sealing kit for protective cover (Part No. 781693, 781694) and an ​
increased protection level from IP 44 to IP 55.
13
14
Application example
107
Manual Call Points
Small Design (ABS)
Small Design (ABS)
The new generation of manual call points meets the latest multi-cultural requirements of the EN 54 ​
- 11 standards as type A (single action). The elegant housing is provided with a pictogram, which ​
can be understood by children as well as in an international context.
Depending on individual requirements, the pictogram can be easily replaced by optional labeling ​
field foils without using additional tools for removal. The actuation field is marked by arrows ​
pointing towards it. The innovative manual call points can be tested by using the key to activate the ​
triggering mechanism, which is hidden by a faceplate. Smart housing and terminal design enables ​
easy installation.
1
88
7
21
If the glass pane is replaced with the optionally available plastic pane with reset function, the ​
MCP can be reset from the outside using the key.
For the surface mounting of the MCP the surface mount base Part No. 704980 must be ​
ordered separately, if the cable wasn't laid about a standard flush mount wall socket.
88
Features
Type a definition - single action in accordance with EN 54-11 § 3.4.1
(excerpt taken from EN standard):
Manual fire alarm unit, for which the alarm status is automatically set (additional alarm ​
triggering is not required) after the fragile element has been broken or its position has been ​
changed.
• Slimline design
• Low power consumption
• Plug-in connection terminals (two direction)
• Optional terminal terminals
• Triple key function (test, open, reset)
• Detectors that are not ready for operation can ​
be marked with the "Out of order" label by ​
reversing the enclosed glass pane
Compact MCP Versions - Conventional
804970
Conventional MCP compact, small, red, glass pane
1
Approval: VdS, CNBOP
Including housing and alarm indicator. For connection to a conventional detection zone.
Technical Data
Operating voltage
Quiescent current @ 9 V DC
Alarm current @ 9 V DC
No. of detector/zone
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Detector specification
Dimensions
Declaration of Performance
8 ... 30 V DC
approx. 0 μA
typ. 9 mA
10 detectors per zone (according to VdS)
red LED and yellow actuation indicator
max. 2.5 mm² (AWG 26-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP43, IP55 with cover 704965
PC ASA plastic
red, similar to RAL 3020
approx. 110 g
EN 54-11, type A
W: 88 mm H: 88 mm D: 21 mm
DoP-20486130701
1 x Glass pane 704960
1 x Key 704966
1 x Multilingual paper labels with "Out of order" pictogram.
Accessories
704980 Surface mount housing
108
www.hls-austria.com
Manual Call Points
804971
Small Design (ABS)
1
IQ8MCP compact, small, red, with isolator and glass pane
1
Approval: VdS, CNBOP
Suitable for esserbus and powered loop connection, with soft address coding, alarm latch and ​
alarm indicator. Conventional detectors can be connected to input of the MCP. Without BUS ​
communication, the detector operates as conventional MCP. Detector housing is included.
Built in isolators maintaining loop integrity.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Alarm current w/o communication curtain
No. of detector/zone
Operation indicator
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Detector specification
Dimensions
Declaration of Performance
2
3
8 ... 42 V DC
approx. 45 μA
approx. 18 mA
max. 127 detectors per loop (according to VdS)
LED, green
red LED and yellow actuation indicator
max. 2.5 mm² (AWG 26-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP43, IP55 with cover 704965
PC ASA plastic
red, similar to RAL 3020
approx. 110 g
EN 54-11, type A
W: 88 mm H: 88 mm D: 21 mm
W: 88 mm H: 88 mm D: 57 mm (with surface mount ​
housing)
DoP-20492130701
4
5
6
7
8
1 x Glass pane 704960
1 x Key 704966
1 x Multilingual paper labels with "Out of order" pictogram
9
Accessories
704980 Surface mount housing
10
804973
IQ8MCP compact, small, red, with resettable element
1
11
Approval: VdS
Same as 804971, but with plastic triggering element, which supports easy reset after an alarm has ​
been triggered without having to replace the broken element (glass pane).
Typically applied in nursery, clean rooms as for example in food processing industries.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Alarm current w/o communication curtain
No. of detector/zone
Operation indicator
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Detector specification
Dimensions
12
8 ... 42 V DC
approx. 45 μA
approx. 18 mA
max. 127 MCP per loop
LED, green
red LED and yellow actuation indicator
max. 2.5mm² (AWG 26-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP43 (in housing)
ASA plastic
red, similar to RAL 3020
approx. 110 g
EN 54-11, type A
W: 88 mm H: 88 mm D: 21 mm
W: 88 mm H: 88 mm D: 57 mm (with surface mount ​
housing)
13
14
1x Plastic operating panel 704964
1x Key 704966
1x Multilingual paper insert with "Out of order" pictogram included
Accessories
704980 Surface mount housing
109
Manual Call Points
804961
Small Design (ABS)
IQ8MCP compact IP 66, small, red, with isolator glass pane
1
Approval: G 205132
Suitable for esserbus and powered loop connection, with soft address coding, alarm latch and ​
alarm indicator. Without BUS communication, the detector operates as conventional MCP. Detector ​
housing, surface mount housing and transparent cover are included.
Due to the high IP protection IP66 suitable for use in humid areas. Surface mount housing is ​
provided with knock-out cable entries for M20 cable glands (option) for simplified installation.
Features
• High IP protection class IP66
• Integrated loop isolator
• Triple key function (test, open, reset)
• Plug-in connection clamps
• Detectors that are not ready for operation can ​
be marked with the "out of order" label by ​
reversing the enclosed glass pane
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Alarm current @ 9 V DC
No. of detector/zone
Operation indicator
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Detector specification
Dimensions
1 x Spare glass 704960
1 x Plastic spare key 704966
1 x transparent cover
1 x Surface mount housing
Example (optional fittings)
110
www.hls-austria.com
8 ... 42 V DC
approx. 45 μA
typ. 18 mA
10 detectors / group; 127 detectors / ring (according ​
to VdS)
LED, green
LED, red and yellow flag
max. 1,5 mm² (AWG 30-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP66
PC-ASA plastic
red, similar to RAL 3020
approx. 250 g
EN 54-11, type A
W: 88 mm H: 88 mm D: 57 mm (with surface mount ​
housing)
Manual Call Points
Small Design (ABS)
1
Plastic Housings
Housings for electronic modules Part No. 80495x.
1
Technical Data
Type of protection
Housing
Installation
Weight
Dimensions
2
IP 43, IP 55 with 704965
PC ASA plastic housing
surface mount
approx. 33 g
W: 88 mm H: 88 mm D: 21 mm
3
1 x Key 704966
704950
4
Housing for small MCP, red, similar to RAL 3020
Technical Data
Declaration of Performance
5
DoP-20492130701
The red manual call point housing is available only with the pictogram (as shown) according ​
to EN 54-11.
6
Please note that according to EN54-11, the label for the MCP must include the symbol of the ​
burning house.
7
Pictogram according to EN54-11
704951
Housing for small MCP, blue, similar to RAL 5015
8
Labeling foil set (white) for various international applications.
9
704952
Housing for small MCP, yellow, similar to RAL 1021
Labeling foil set (black) for various international applications.
704953
10
Housing for small MCP, orange, similar to RAL 2011
11
Labeling foil set (black) for various international applications.
704954
Housing for small MCP, green, similar to RAL 6002
12
Labeling foil set (white) for various international applications.
13
14
111
Manual Call Points
Small Design (ABS)
Surface Mount Housings
1
The surface mount housing serves as cable entry for surface mount cabling. With integrated ​
support for shielding.
Technical Data
Dimensions
W: 88 mm H: 88 mm D: 36 mm
Mounting material
704980
Surface mount housing for small MCP, red, similar to RAL 3020
Red, for manual call points Part No. 804970, 804971 and 804973, for small design electronic ​
modules Part No. 804950/51, 804955/56 with housing Part No. 704950.
704981
Surface mount housing for small MCP, blue, similar to RAL 5015
Blue, for small design electronic modules Part No. 804950/51, 804955/56 with housing Part No. ​
704951.
704982
Surface mount housing for small MCP, yellow, similar to RAL 1021
Yellow, for small design electronic modules Part No. 804950/51, 804955/56 with housing Part No. ​
704952.
704983
Surface mount housing for small MCP, orange, similar to RAL ​2011
Orange, for small design electronic modules Part No. 804950/51, 804955/56 with housing Part No. ​
704953.
112
www.hls-austria.com
Manual Call Points
Small Design (ABS)
1
Electronic Modules - Conventional
804950
2
Conventional MCP electronic module
1
Approval: VdS
With alarm indicator, for the connection to a standard detector zone.
Technical Data
Operating voltage
Quiescent current @ 9 V DC
Alarm current @ 9 V DC
No. of detector/zone
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Weight
Detector specification
Dimensions
Declaration of Performance
3
8 ... 30 V DC
approx. 0 μA
typ. 9 mA
max. 10 detectors per loop (as per VdS)
LED, red and yellow flag
max. 2,5 mm² (AWG 26-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP 43 (in Housing), IP 55 with cover 704965
approx. 78 g
EN 54-11, type A
W: 88 mm H: 88 mm D: 21 mm
W: 88 mm H: 88 mm D: 57 mm (with surface mount ​
housing)
DoP-20486130701
4
5
6
7
1 x Glass pane 704960
1 x Multilingual paper labels with "Out of order" pictogram
804951
8
9
Conventional MCP electronic module, with 2nd micro-switch
1
Approval: VdS
Same as 804950, but with second microswitch with dry contact NC/C (break) or NO/C (make) that ​
is activated when the alarm is triggered.
Technical Data
Operating voltage
Quiescent current @ 9 V DC
Alarm current @ 9 V DC
Contact load
No. of detector/zone
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Weight
Declaration of Performance
10
11
8 ... 30 V DC
approx. 0 μA
typ. 9 mA
30 V DC/1 A
max. 10 detectors per loop (as per VdS)
LED, red and yellow flag
max. 2,5 mm² (AWG 26-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP 43 (in housing), IP 55 with cover 704965
approx. 78 g
DoP-20485130701
12
13
14
113
Manual Call Points
Small Design (ABS)
Electronic Modules - Addressable
804955
IQ8MCP electronic module
1
Approval: VdS
Same as 804971, but without housing.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Alarm current w/o communication curtain
No. of detector/zone
Operation indicator
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Weight
Detector specification
Dimensions
Declaration of Performance
8 ... 42 V DC
approx. 45 μA
approx. 18 mA
max. 127 detectors per loop (as per VdS)
LED, green
red LED and yellow actuation indicator
max. 2.5 mm² (AWG 26-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP43 (in housing), IP 55 with cover 704965
approx. 78 g
EN 54-11, type A
W: 88 mm H: 88 mm D: 21 mm
DoP-20492130701
1 x Glass pane 704960
1 x Multilingual paper labels with "Out of order" pictogram
804956
IQ8MCP electronic module w/o isolator, with relay
1
Approval: VdS
Same as 804955, but with relay and without loop isolator or connection possibility for standard ​
manual call points. The relay output is activated by the triggering of this detector. The relay output ​
can be programmed in the IQ8Control and System 8000 FACP customer data as a control group.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Alarm current w/o communication curtain
Contact load
No. of detector/zone
Operation indicator
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Weight
114
www.hls-austria.com
8 ... 42 V DC
approx. 45 μA
approx. 18 mA
30 V DC / 1 A
max. 127 detectors per loop (as per VdS)
LED, green
LED, red and yellow flag
max. 2.5 mm² (AWG 26-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP43 (in housing), IP 55 with cover 704965
approx. 78 g
Manual Call Points
Accessories for MCP small design
1
704960
Spare glass pane for small MCP, EN54
1
Spare glass pane with white stick-on foil and printed pictogram in compliance with EN 54-11 (type ​
A). Suitable for small MCPs.
Technical Data
Dimensions
2
W: 56 mm H: 49.5 mm D: 1.85 mm
To indicate that the detector is "Out-of-order" the operator has a corresponding pictogram on ​
the reverse side.
3
10 pcs
4
704975
Spare glass pane for small MCP, EN54, neutral
1
Spare glass pane with white stick-on foil and printed with pictogram according to EN 54-11 (type ​
A), for small manual call points, without logo.
Technical Data
Dimensions
5
6
W: 56 mm H: 49.5 mm D: 1.85 mm
To indicate that the detector is "Out-of-order" the operator has a corresponding pictogram on ​
the reverse side.
7
10 pcs
8
704964
Resettable element for small MCP
1
Resettable, white plastic, for small manual call points. Typically applied, for instance, in food ​
processing industries or in clean rooms.
Technical Data
Material
Dimensions
Declaration of Performance
9
ABS
W: 56 mm H: 49.5 mm D: 1.85 mm
DoP-20492130701
10
To indicate that the detector is "Out-of-order" the operator has the same pictogram as shown ​
above on the reverse side.
11
10 pcs
12
2
13
1
Release
the MCP
Released
MCP
Resetting
the MCP
MCP ready
for operation
14
Application example
115
Manual Call Points
Accessories for MCP small design
704965
Protective kit for MCP and TAL, transparent
1
Transparent, suitable for small MCPs. The cover serves as a protection to prevent inadvertent ​
activation and to protect from high humidity.
Technical Data
Type of protection
Material
IP55
plastic cover, transparent
Cover and two neoprene seals
Application example: Manual call point with mounted cover
704966
Plastic spare key for small MCP
1
Plastic key, red, suitable for small manual alarm units.
10 pcs
704967
Mounting frame for small MCP, red and white
1
The mounting frame is useful for mounting MCPs on different international flush mount boxes.
Technical Data
Color
red, similar to RAL 3020
white, similar to RAL 9010
W: 132 mm H: 132 mm D: 8 mm
Dimensions
2 x Fastening screws are included (red and white)
or
Application example: Mounting frame with small MCP
116
www.hls-austria.com
Manual Call Points
761694
Special Design
1
Addressable MCP, IP66
1
Approval: G 209190
2
Addressable manual call point in conformity with EN 54-11 type B with loop isolator for manually ​
triggering fire alarms or hazard alarms. For outdoor application or application in damp environ­
ments.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
No. of detector/zone
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
Declaration of Performance
3
8 ... 42 V DC
approx. 45 μA
max. 10 (according to VdS), 127 / loop
LED, red
max. 1.5 mm²
-20 °C ... 70 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
IP66
PC-plastic
red, similar to RAL 3000
approx. 475 g
W: 135 mm H: 135 mm D: 61 mm
DoP-20882130701
4
5
6
7
Please take note, our Part No. 769910 and 769911 can be used as spare keys.
To indicate that the detector is "Out-of-order" the operator has to insert the paper inlay, which ​
has a corresponding pictogram and wording.
8
1 x Glass 704910
1 x Key and “Out of order” sign or “Außer Betrieb”
W1A-R1K0SG-U007-01
Accessories
704910 Spare glass for MCP
769910 Plastic key for large MCP
769911 Metal key for large MCP
9
Manual call point IP67, small housing, red
11
10
1
The outdoor MCP is an IP 67 sealed product. The enhanced environmental protection ​allows the
unit to be installed in many external environments where water and dirt are likely ​to be present,
making it a true waterproof and outdoor product.
The manual call point has a unique ‘plug and play’ concept designed specifically to reduce ​installation time. The product utilizes a special terminal block, where all initial installation ​cabling is terminated. This terminal block is then simply connected to the back of the MCP. ​The housing is
supplied with three standard 20mm knock outs for cable entries, accom­modating all types of
surface wiring installations.
The MCP also helps to preserve the integrity of the overall system as illegal removal of the ​product
lid will result in the call point operating and the system triggering an alarm.
Features
• Sealed to IP 67
• Unique ‘plug and play’ installation concept
• Anti-tamper facility
• Enhanced aesthetics and compact design
• Approved to EN 54-11
Technical Data
Application temperature
Storage temperature
Air humidity
Type of protection
Material
Weight
Detector specification
Dimensions
12
13
14
-30 °C ... 70 °C
-30 °C ... 70 °C
< 95 % non condensing
IP 67
PC/ABS
approx. 240 g
EN 54-11
W: 97.5 mm H: 93 mm D: 71 mm
1 x Cable gland included
Accessories
MUS155 Spare glass pane (5 pcs)
SC070 Spare key
PS200 Plastic cover
117
Manual Call Points
Special Design
Manual Call Points Intrinsically Safe
W1A-R1K0SG-E019-81
Ex manual call point IP67, small housing, red
1
Approval: LPCB, ATEX
Features
• Sealed to IP67
• Unique ‘plug and play’ installation concept
• Anti-tamper facility
• Enhanced aesthetics and compact design
• Approved to EN 54-11
The Ex MCP is built especially for installation in hazardous areas. It is intended for outdoor ​use
within intrinsically safe systems using suitable barriers.
The outdoor MCP is an IP 67 sealed product. The enhanced environmental protection ​allows the
unit to be installed in many external environments where water and dirt are likely ​to be present,
making it a true waterproof and outdoor product.
The manual call point has a unique ‘plug and play’ concept designed specifically to reduce ​installation time. The product utilizes a special terminal block, where all initial installation ​cabling is terminated. This terminal block is then simply connected to the back of the MCP. ​The housing is
supplied with three standard 20mm knock outs for cable entries, accom­modating all types of
surface wiring installations.
The MCP also helps to preserve the integrity of the overall system as illegal removal of the ​product
lid will result in the call point operating and the system triggering an alarm.
Technical Data
Application temperature
Storage temperature
Air humidity
Type of protection
Material
Weight
Detector specification
ATEX certificate
Ex-category
Dimensions
-25 °C ... 70 °C
-25 °C ... 70 °C
< 93 % ±3% non condensing
IP67
PC/ABS
approx. 350 g
EN 54-11
Sira 06ATEX2131X
II 1GD EEXiaIICT
W: 97.5 mm H: 93 mm D: 71 mm
! Attention – cable glands not included in delivery.
Accessories
706031 Spare glass plane (5 pcs)
706032 Spare key
706033 Plastic cover
764744 Ex-barrier
118
www.hls-austria.com
Manual Call Points
804960.EX
Special Design
1
Small Conventional MCP Ex (i) IP 66/67, red with glass pane
1
Approval: G 214115
2
The small compact version has detector housing, surface mount housing, transparent cover, and
alarm indicator. For connection to a conventional zone for use in ex-areas. Suitable for use in
damp rooms thanks to the high IP 66/67 IP protection. Surface mounting housing is provided with
break-out cable entries for M20 cable glands (optional) for easy installation.
Features
• High IP protection class IP66 & IP67
• Triple key function (test, open, reset)
• Plug-in terminals
• “Out of Order” indication of an inoperative alarm by
flipping over the glass pane
Technical Data
Data according to ATEX:
Max. Input Voltage (Ui)
Max. Input current (Ui)
Ambient temperature (Ta)
EC-type examination certificate
Ex-category
Explosion protection
Specification
Common technical data:
Operating voltage
Alarm current @ 9 V DC
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Material
Weight
Color
Detector specification
Dimensions
Declaration of Performance
3
4
21 V DC
252 mA
-20 °C ... 70 °C
TÜV 14 ATEX 150860
II 2G (with Ex barrier Part-No. 764744 / 804744)
Ex ib IIC T4 Gb
EN 60079-0:2012 + A11:2013 / -11:2012
5
8 ... 30 V DC
typ. 9 mA
red LED and yellow actuation indicator
max. 1,5 mm² (AWG 30-14)
-20 °C ... 70 °C
-20 °C ... 70 °C
< 95 % (non condensing)
IP66, IP67
PC ASA plastic
approx. 255 g
red, similar to RAL 3020
EN 54-11 : 2001 + A1:2005, Typ A
W: 88 mm H: 88 mm D: 63 mm (w. surface mount h.)
DoP-21415141219
6
7
8
9
Use M20 cable glands with 15 mm connecting thread length and sealing ring, e.g. blueglobe by Pflitsch
(cable gland Part No.: bg 820PA/sealing ring Part No.: DRF 220).
For detailed information on installation and operation, see documentation Part No. 798920.
For operation with standard groups ex-barrier Part No. 764744 must be used in zone 1 and zone 2!
10
1 x glass pane 704960
1 x key 704966
1 x surface mounting housing
1 x transparent cover
11
12
13
14
119
Manual Call Points
804920.EX
Special Design
Large Conventional MCP Ex (i) IP 66/67, red with glass pane
1
Approval: G 214113
Standard large intrinsically safe MCP, consisting of electronic module and detector housing, for
connection to a conventional zone, especially for use in hazardous areas. Suitable due to the high
IP protection up to IP 55 for use in damp rooms.
Features
• High IP protection up to IP55
• Plug-in terminals
• Standard keys with double function: Open, reset
• Service key with triple function: Test, open, reset
• "Out of Order" marking an inoperative detector by
turning the enclosed operating front foil
Technical Data
Data according to ATEX:
Max. Input Voltage (Ui)
Max. Input current (Ui)
Ambient temperature (Ta)
EC-type examination certificate
Ex-category
Explosion protection
Specification
Common technical data:
Operating voltage
Alarm current @ 9 V DC
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Material
Weight
Color
Detector specification
Dimensions
Declaration of Performance
21 V DC
252 mA
-20 °C ... 70 °C
TÜV 14 ATEX 150860
II 2G (with Ex barrier Part-No. 764744 / 804744)
Ex ib IIC T4 Gb
EN 60079-0:2012 + A11:2013 / -11:2012
8 ... 30 V DC
typ. 9 mA
LED, red
max. 1,5 mm² (AWG 30-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non condensing)
IP44, IP55 with shrink sleeve
PC ASA plastic
approx. 236 g (in housing)
red, similar to RAL 3020
EN 54-11: 2001 + A1:2005, Typ A
W: 133 mm H: 133 mm D: 36 mm
DoP-21415141219
For detailed information on installation and operation, see documentation part no. 798920. For operation
with standard groups ex-barrier item no. 764744 must be used in zone 1 and zone 2!
1 x glass pane 704960
1 x key 769910
1 x Manual call point housing, red
1 x IP 55 shrink sleeve
120
www.hls-austria.com
Manual Call Points
761697
Special Design
1
Explosion-proof conventional MCP, IP66
1
Approval: VdS, PTB 97 ATEX 3197
2
Explosion-proof encapsulated conventional manual call point for hazardous areas in conformity ​
with EN 54-11 Type B for the manual actuation of a fire alarm and/or a hazard alarm, as a detector ​
for usage in explosion-hazardous areas both inside and outside.
3
The operating front foil has been designed as a double-sided insert. Complementary to the ​symbolism conforming to the standards for manual call points in compliance with EN 54-11 (Type ​B), it
has a symbol and multilingual text on the back for the "Out of order" status of the detector ​and is
always available for possible maintenance work.
4
The labeling foil of the manual call point also has a double-sided design. In compliance with EN ​
54-11, it contains the standard symbol of a burning house. On the back, the symbol is supple­
mented with the word “FIRE” (multilingual).
Technical Data
Data according to ATEX:
Ex-category
Explosion protection
Common technical data:
Operating voltage
Alarm current
No. of detector/zone
Circuit
Connection terminal
Application temperature
5
6
II 2G
Ex e d mb IIC T6, T5
12 ... 24 V DC
approx. 9 mA
max. 10 detectors per Zone (according to VdS)
1 k/10 k (internal)
0.6 mm ... 4 mm²
-55 °C ... 65 °C
-55 °C ... 85 °C (T5)
-55 °C ... 85 °C
< 95 % (non-condensing)
IP66
Glass fiber reinforced polyester resin
red, similar to RAL 3000
approx. 1.8 kg
DIN 14678 Form K
W: 136 mm H: 138 mm D: 88 mm
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Detector specification
Dimensions
7
8
9
10
Please note, an Allen key (size 4) is needed for opening and resetting the MCP, and is not ​
included in the scope of delivery.
11
1 x Glass pane 704910
1 x Kit of double-sided operating front foil (with "Out of order" on the back)
1 x Kit of double-sided labeling foil (multilingual)
12
Accessories
704910 Spare glass pane for MCP housings
Out of
Order
13
Außer
Betrieb
14
fuera
de servicio
POZAR
hors
service
FEUER
FIRE
FEU
FUEGO
Feuerwehr
Operating front foils and labeling foils
121
Manual Call Points
PS200
Special Design
Transparent cover for MCP
Spare transparent cover for addressable manual points.
SC070
Spare keys pack for MCP
10 spare keys for addressable MCP. The MCP key is used to open, reset and test the MCPs.
10 pieses
122
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
11
Transponders / Input & Output Modules
esserbus
124-135 12
13
14
123
Transponders / Input & Output Modules
esserbus
Professional fire detection systems are expected to provide more than reliable fire detection and ​
signaling alarms to the fire brigade. Over time, the continuous progress in technical units has led to ​
many improvements in monitoring and control systems. At the same time the specifications of the ​
European standards are becoming more and more demanding. These complex requirements ​
towards control and monitoring of individual parts of a unit was reason enough to redesign our ​
assortment of esserbus transponders.
Essentially the new assortment consists of the so-called "alarm transponder" which is used for b​ oth
the connection of non-addressable detectors (point-type detectors, manual detectors and ​special
detectors) as well as for the operation of conventional alarm signaling devices (signaling ​devices,
signal flasher and combination alarm signaling devices). Monitoring of the lines in accord­ance with
the latest standards is ensured via "EOL modules" (end-of-line modules).
The second part is formed by the "FCT" (fire control transponder) and the IQ8TAL being loop-​
powered input and output transponders with a contact input and a floating relay output for monit­
oring of contacts and transmission of technical alarms for equipment monitoring.
These modules with low power consumption are for interfacing to other disciplines which are not a ​
part of the fire detection system itself. Thanks to their intelligent concept they significantly expand ​
the range of monitoring and control functions as part of the building management.
Take note, esserbus transponders need ONLY ONE loop address per device, anyway how ​
much inputs or outputs are switched - i.e. in case that more than one input/output per ​
device is needed, this feature reduces the quantity of transponders needed!
124
www.hls-austria.com
Transponders / Input & Output Modules
808623
esserbus
1
esserbus alarm transponder, 4 IN/2 OUT with isolator
1
Approval: VdS
2
Features
• Only one loop address is needed per ​transponder
• Digital inputs
• Integrated loop isolator
• Conventional connection of standard fire ​detectors and signaling devices
• Loop monitoring in compliance with EN 54-13
• Integrated loop isolator
• Programmable relay outputs
• Programmable relay reset function
• Max. 100 transponders per FACP
• Max. 31 transponders per loop
• Max. 127 detector zones per loop
• Detector numbers per zone input of the ​transponder:
• Max. 30 conventional detectors (without SOC)
• Max. 10 conventional detectors (with SOC)
• Max. 10 Manual call points (MCP)
• Max. 10 Technical Alarm Modules (TAM)
• Max. 5 audible alarm devices per each output ​
(observe calculation table in tools 8000)
The esserbus transponder functions as a device on the multi-functional primary line. The connec­
tion of four zones with automatic standard detectors, manual call points (non-addressable) as well ​
as special detectors is possible. In addition, two programmable relay outputs are also available.
Both relay outputs of the transponder may be used to reset a connected third-party detector. The ​
reset function relates to the corresponding special detector, e.g. by switching the appropriate input ​
to GND or by a short interruption of the detectors supply voltage. Therefore the control mode ​
>Reset-Relay< as well as the desired relay operation mode (normally closed or open) must be ​
configured with the programming software tools 8000 from V1.15 and above. The relay output will ​
be activated for the selected reset time (1 to 14 seconds) if the assigned input (G1 for relay 1/G2 ​
for relay 2) of the transponder is reset. Refer to the detectors manual for the required reset time.
3
4
5
Monitoring via the EOL terminating devices (Part No. 808624/808626) is required for the connec­
tion of fire detectors and for the controlling of alarm signaling devices. The enclosed resistors can ​
be used to connect the floating contacts.
6
The esserbus alarm transponder requires an external voltage supply. An optional Voltage ​
Converter (Part No. 781336) is also required for 12V DC operation. The esserbus alarm ​transponder external voltage supply can be monitored during operation.
7
The EOL-I terminating device (Part No. 808626) must be used for standard-compliant monitoring ​
of detector zone inputs. The EOL-O (Part No. 808624) must be used for standard-compliant monit­
oring of connected alarm signaling devices.
8
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Current consumption
Contact load relay
Ambient temperature
Storage temperature
Air humidity
Type of protection
Weight
Dimensions
Declaration of Performance
10 ... 28 V DC
approx. 12 mA
max. 120 mA @ 12 V DC
30 V DC / 1 A
-10 °C ... 50 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
IP 40 (in housing)
approx. 28 g
W: 82 mm H: 72 mm D: 20 mm
DoP-21057130701
9
10
11
Installation accessory pack
12
Accessories
788603.10 Module housing for snap-on mounting rail
788600
Housing surface mount, gray
788650.10 Housing surface mount, white
788601
Housing flush mount, gray
788651.10 Housing flush mount, white
788612
Loop isolator for transponder
781336
DC/DC converter output voltage
808624
EOL-O Terminating device
808626
EOL-I Terminating device
13
14
125
Transponders / Input & Output Modules
808623.10
esserbus
esserbus transponder for UniVario with isolator
1
Approval: VdS
The interface connects max. 2 industrial sensors from the UniVario product range. These sensors ​
are supplied with energy via the 9 V DC group voltage input. For meeting the standard require­
ments of monitoring, an EOL-UV terminal element is connected to the sensor base of the UniVario ​
sensor. The interface requires external voltage supply. Additionally, two optionally monitored relay ​
outputs are available.
Features
• Only one loop address is needed per ​transponder
• Digital input
• Loop monitoring in compliance with EN 54-13
• Integrated loop isolator
• Programmable relay outputs
• Programmable relay reset function
• Max. 100 transponders per fire alarm control ​
panel
• Max. 31 transponders per loop
• Max. 127 detector zones per loop
• Detector numbers per zone input of the ​transponder:
• Max. 30 conventional detectors (without SOC)
• Max. 10 conventional detectors (with SOC)
• Max. 10 Manual call points
• Max. 10 Technical Alarm Modules (TAM)
• Max. 5 audible alarm device (observe calcula­
tion table in tools 8000)
126
www.hls-austria.com
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Current consumption
Contact load relay
Ambient temperature
Storage temperature
Air humidity
Type of protection
Weight
Dimensions
Declaration of Performance
10 ... 28 V DC
approx. 12 mA
max. 120 mA @ 12 V DC
30 V DC / 1 A
-10 °C ... 50 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
IP 40 (in housing)
approx. 28 g
W: 82 mm H: 72 mm D: 20 mm
DoP-21057130701
Installation Accessory Pack
Accessories
788603.10 Module housing for snap-on mounting rail
788600
Housing surface mount, gray
788650.10 Housing surface mount, white
788601
Housing flush mount, gray
788651.10 Housing flush mount, white
788612
Loop isolator for transponder
781336
DC/DC converter output voltage
808626
EOL-I Terminating Device
Transponders / Input & Output Modules
808621
esserbus
1
esserbus transponder IQ8FCT LP
1
Approval: VdS G 209138
The IQ8FCT LP is used to control and monitor external fire control devices like fire dampers or as
a technical alarm component (TAL) to monitor an external contact and control external load.
The transponder is connected on the esserbus/esserbus-PLus loop of fire control system FlexES
Control and IQ8Control.
Features
• Module for controlling and monitoring fire protection devices
• Power supply via the field bus esserbus
• Output switching load up to 230 V AC / 16 A
• Programmable run-time monitori
• Configurable fail safe functionality
• Manual output activation at transponder
• Robust IP 65 protected surface mount housing
• Silicone cable entries for fast installation
2
3
FCT functionality
In this function a fire control device e.g. fire damper is connected to the relay output of the IQ8FCT
LP and controlled according to the programming with configured runtime. Via the input the end
positions of this external device are monitored. If the external device is leaving the set position e.g.
at a power loss or is stuck a failure is recognized and indicated at the IQ8FCT LP and the fire
control panel. The IQ8FCT LP is also equipped with configurable fail save functionality.
If enabled, a communication loss with control panel results in automatic selfactivation of relay
output.
4
5
TAL functionality
Here an external contact can be connected and monitored via the input of the IQ8FCT LP. In case
of an activation of this contact, the address and programmed additional text of the corresponding
technical alarm module IQ8FCT LP will be displayed.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Relay contact
Input monitoring
(at use of external resistors)
Input line length
System limitations
Input / loop terminals
Relay contact / power supply terminals
Ambient temperature
Storage temperature
Air humidity
Type of protection
Color
Weight
Dimensions
Declaration of Performance
6
7
14 ... 42 V DC
approx. 45 mA
max. 16 A resistive or 8 A inductive load of 230 V AC
or 30 V DC surge resistance 250 A @ 10 ms
potential-free or voltage switching / COM/NO/NC
FCT mode: 1 k / 6 k8 / 10 k
TAL mode: 1 k / 10 k (NO) or 6 k8 / 10 k (NC)
500 m
max. 127 pieces per loop
max. 2,5 mm² (AWG 26-14)
max. 6 mm2 (AWG 30-10)
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP65
gray, similar to RAL 7035
approx. 250 g
W: 150 mm H: 116 mm D: 67 mm
DoP-20792130701
8
9
10
11
12
Accessories
804870 Alarm and monitoring module for IQ8TAM
13
14
127
Transponders / Input & Output Modules
808606
1
esserbus
esserbus transponder IQ8FCT XS
Approval: VdS G 209138
The IQ8FCT XS can be used to control and monitor external fire protection devices like fire
dampers or as a technical alarm module (TAL) to monitor an external contact and control external
load.
The transponder is connected on the esserbus® /esserbus®-PLus loop of fire control system
FlexES Control and IQ8Control.
Features
• Module for controlling and monitoring fire protection devices
• Compatible with FlexES Control and IQ8Control
• Power supply via the field bus esserbus
• Integrated loop isolator
• Programmable run-time monitoring (fire
dampers)
• Space-saving installation due to compact design
• Installation on hat rail 35 mm
• Optional housing for surface mounting
FCT functionality
In this function a fire control device e.g. fire damper will be connected to the relay output of the
IQ8FCT XS and controlled according to the programming with configured runtime. Via the input the
end positions of this external device are monitored. If the external device is leaving the set position
e.g. at a power loss or is stuck a failure is recognized and indicated at the IQ8FCT XS and the fire
control panel.
TAL functionality
Here an external contact can be connected and monitored via the input of the IQ8FCT XS. In case
of an activation of this contact, the address and programmed additional text of the corresponding
technical alarm module IQ8FCT XS will be displayed.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Relay contact
Input monitoring
Input line length
System limitations
Input / loop terminals
Ambient temperature
Storage temperature
Air humidity
Type of protection
Color
Weight
Dimensions
Declaration of Performance
14 ... 42 V DC
approx. 45 mA
max. 1 A / 30 V DC ot AC
potential-free / COM / NO / NC
FCT mode: 1 k / 6 k8 / 10 k
TAL mode: 1 k / 10 k (NO)
500 m
max. 127 pieces per loop
max. 2,5 mm² (AWG 26-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP30
IP50 (w. housing M200SMB/SMB6-V0)
gray, similar to RAL 7035
approx. 90 g
approx. 250 g (w. housing M200SMB)
approx. 790 g (w. housing SMB6-V0)
W: 90 mm H: 93 mm D: 93 mm
W: 130 mm H: 143 mm D: 49 mm (w. h. M200SMB)
W: 245 mm H: 180 mm D: 100 mm (w. h. SMB6-V0)
DoP-20792130701
Accessories
804870 Alarm and monitoring module for IQ8TAM
M200SMB Surface mounting housing for one module
SMB6-V0 Surface mounting housing for 6 modules
128
www.hls-austria.com
Transponders / Input & Output Modules
808610.10
esserbus
1
esserbus transponder 12 relays (8 bit)
1
Approval: VdS, CNBOP, BOSEC
Features
• Only one loop address is needed per ​transponder
• Max. 100 transponders per FACP
• Max. 32 transponders per loop
• Max. 32 transponders per detector zone
The esserbus transponder works as a loop device on the multi-functional primary line. With the 12 ​
relays module, it is possible to expand the number of exits per control unit. Depending on the ​
control unit, it can be integrated or used with fire detectors in mixed operation. The esserbus ​transponder can be optionally extended by adding the additional isolator board Part No. 788612. ​
esserbus transponder voltage supply: via the multi-functional primary line. The esserbus ​transponder can be wired with an external switching voltage of 12V DC or 24V DC for the K1 to ​K12
relays. The external voltage supply of the transponder can be programmed to be monitored in ​the
customer data in the operating mode. In the “floating” operating mode, no external switching ​
voltage of the relays is necessary. 11 relays are freely programmable. The maximum line length ​
from the transponder to the external device is up to 1000 m.
2
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Current consumption @ 12 V DC
Contact load relay
Ambient temperature
Storage temperature
Air humidity
Type of protection
Weight
Dimensions
Declaration of Performance
5
3
4
10 ... 28 V DC
approx. 250 μA
approx. 3 mA
30 V DC / 1 A (max. 3 A each transponder)
-10 °C ... 50 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
IP 40 (with housing)
approx. 110 g
W: 150 mm H: 82 mm D: 20 mm
DoP-20611130701
6
7
8
External power supply is only optional – the transponder is fully operational with loop ​powering only.
Accessories
788612
Loop isolator PCB
788600
Surface mounting housing gray, similar to RAL 7035
788650.10 Surface mounting housing white, similar to RAL 9003
788601
Flush mounting housing gray, similar to RAL 7035
788651.10 Flush mounting housing white, similar to RAL 9003
9
10
11
12
13
14
129
Transponders / Input & Output Modules
808611.10
esserbus
esserbus transponder 32 LED
1
Approval: VdS, CNBOP, BOSEC
Features
• Only one loop address is needed per ​transponder
• Max. 100 transponders per FACP
• Max. 32 transponders per loop
• Max. 32 transponders per detector zone
The esserbus transponder works as a loop device on the multi-functional primary line. 32 opto­
coupler outputs for direct LED control (e.g. indicator) are found on this esserbus transponder ​
module. There is one terminal screw per output on the switching mechanism. The module can be ​
extended by adding the additional isolator board Part No. 788612. esserbus transponder voltage ​
supply: via the multi-functional primary line. The esserbus transponder requires an external power ​
supply.
The external voltage supply of the transponder can be programmed to be monitored in operating ​
mode. The maximum line length from the transponder to the external device is up to 100 m.
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Ambient temperature
Storage temperature
Air humidity
Type of protection
Weight
Dimensions
Declaration of Performance
10 ... 15 V DC
approx. 3 mA
-10 °C ... 50 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
IP 40 (with housing)
approx. 95 g
W: 150 mm H: 82 mm D: 20 mm
DoP-20611130701
Accessories
788612
Loop isolator PCB
788600
Surface mounting housing gray, similar to RAL 7035
788650.10 Surface mounting housing white, similar to RAL 9003
788601
Flush mounting housing gray, similar to RAL 7035
788651.10 Flush mounting housing white, similar to RAL 9003
808615
esserbus communication transponder for ECP 8010
1
With this esserbus transponder the extinguishing relay output 8010 can be integrated on the bus of ​
panel 8000, IQ8Control and FlexES, thus enabling several extinguishing zones to be networked ​
with each other. On each bus, a maximum of eight 8010 extinguishing relay outputs can be oper­
ated and a maximum of 16 communication transponders for each FACP8000 C/M, IQ8Control and ​
FlexES. All indicators and controls can be activated from the fire alarm panel. The communication ​
transponder occupies one address on the esserbus. With integrated loop isolator on board. ​
Maximum 8 transponders per loop and max. 16 transponders per FACP.
Technical Data
Current consumption
Ambient temperature
Storage temperature
Air humidity
Type of protection
Weight
Dimensions
max. 28 mA
-10 °C ... 50 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
IP 40 (with housing)
approx. 28 g
W: 72 mm H: 65 mm D: 20 mm
Mounting: in the housing of the 8010 extinguishing relay output
Including loop isolator PCB (Part No. 788612)
130
www.hls-austria.com
Transponders / Input & Output Modules
808619.10
esserbus
1
esserbus FSA transponder for fire doors
1
Approval: VdS
2
Features
• Only one loop address is needed per ​transponder
• Usage of series 9200 intelligent detectors (such ​
as OT, OTI, O²T detectors) as FSA detectors is ​
possible
• Connection of IQ8Quad O detectors (Part No. ​
802371), TD Detectors (Part No. 802271), OT ​
detectors (Part No. 802373) and O²T detectors ​
(Part No. 802374) (DIBt-approved) as FSA ​
detectors is possible
• FSA detectors programmable as devices in the ​
loop
• Status indicator of door arrester system to the ​
FACP
• Actuation of the locking device also via the auto­
matic fire detectors in non-FSA operation
• Stand-alone operation of the FSA transponders ​
is possible
• Usage of IQ8Quad O detectors (Part No. ​
803371), TD detectors (Part No. 803271) and ​
O²T detectors (Part No. 803374) in stand-alone ​
operation of the FSA transponders to the ​standard detector group is possible
• Max. 100 transponders per FACP
• Max. 32 transponders per analog loop
• Max. 127 detector zones per analog loop
• Detector numbers per zone input of the ​transponder:
• Max. 30 conventional detectors (without SOC)
• Max. 10 conventional detectors (with SOC)
• Max. 10 Manual call points
• Max. 10 Technical Alarm Modules (TAM/TAL)
The transponder is suitable for usage for various applications: in stand-alone operation or on the ​
esserbus. In esserbus operation, the Series 9200 automatic fire detectors and those of the ​
IQ8Quad family (see features for types) can be used as detectors in door arrester systems (FSA - ​
Fire, Failure and Shut-Off). In FSA transponder loop operation, the door arrester system status is ​
indicated on the fire alarm control panel.
3
For stand-alone operation, detectors of the IQ8Quad family are supported without loop isolator ​
(see features for types).
4
For operation, the transponder requires an external supply voltage. It is possible to monitor this ​
voltage.
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Current consumption
Contact load relay
Ambient temperature
Storage temperature
Air humidity
Type of protection
Weight
Dimensions
Declaration of Performance
5
10 ... 28 V DC
approx. 6 mA (from UB ext)
max. 28 mA (from UB ext)
max. 30 V DC/1 A or 48 V DC/0,5 A
-5 °C ... 50 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
IP 40 (with housing)
approx. 70 g
W: 72 mm H: 65 mm D: 20 mm (PC Board)
DoP-20614130701
6
7
8
Corresponding connection examples for FSA transponder operation in stand-alone operation ​
or as a device in the fire detection System 8000 can be found in the chapter containing ​automatic door release systems.
9
Accessories
788612
Loop isolator PCB
788603.10 Module housing for C-mounting bar or top hat rail mounting
788600
Housing surface mount, gray
788650.10 Housing surface mount, white
788601
Housing flush mount, gray
788651.10 Housing flush mount, white
808625
EOL-Z
10
11
12
13
14
131
Transponders / Input & Output Modules
808630.10
esserbus
esserbus transponder RZT, 24 V
1
Approval: VdS
Features
• For connection of 3rd party detectors
• Only one loop address is needed per ​transponder
• Max. 100 transponders per FACP
• Max. 31 transponders per loop
• Max. 32 transponders per detector zone
The refurbishment zone transponder is a stand-alone participant on the esserbus for the fire alarm ​
system 8000 and IQ8Control FACP. Individual automatic fire detectors and manual call points ​
(conventional technology) from other manufacturers can be connected to the 4 zone inputs. The ​
voltage of all 4 zones can be configured to 24 V via the internal DC/DC module. An additional reset ​
module is not required to operate third-party detectors.
The two relay outputs are available for general control purposes.
Programmable with the programming software tools 8000 Version V2.40 or higher.
Technical Data
Operating voltage
Current consumption
Contact load relay
Ambient temperature
Storage temperature
Air humidity
Weight
Dimensions
Declaration of Performance
10.5 ... 15 V DC
max. 1.250 mA
max. 30 V DC/1 A or 48 V DC/0,5 A
-10 °C ... 50 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
approx. 150 g
W: 150 mm H: 82 mm D: 20 mm
DoP-20615130701
Whether or not a connection is possible must be individually checked in advance by the ​
technical sales department.
Accessories
788612
Loop isolator PCB
788600
Housing surface mount, gray
788601
Housing flush mount, gray
788650.10 Housing surface mount, white
788651.10 Housing flush mount, white
788605
Mounting kit
808631.10
esserbus transponder RZT, 12 V
1
Same as 808630.10, but rated voltage is 12 V DC, not configurable.
Technical Data
Operating voltage
Current consumption
Contact load relay
Ambient temperature
Storage temperature
Air humidity
Weight
Dimensions
Declaration of Performance
Accessories
788612
Loop isolator PCB
788600
Housing surface mount, gray
788601
Housing flush mount, gray
788650.10 Housing surface mount, white
788651.10 Housing flush mount, white
788605
Mounting kit
132
www.hls-austria.com
10.5 ... 13.8 V DC
max. 1.250 mA
max. 30 V DC/1 A or 48 V DC/0,5 A
-10 °C ... 50 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
approx. 150 g
W: 150 mm H: 82 mm D: 20 mm
DoP-20615130701
Transponders / Input & Output Modules
esserbus
1
Accessories for esserbus Transponders
2
788612
Loop isolator for transponder
1
Loop isolator PCB to be mounted on esserbus transponders. To isolate short circuit failure and ​wire
break on the loop.
Technical Data
Ambient temperature
Storage temperature
Air humidity
Type of protection
Weight
Dimensions
Declaration of Performance
3
-20 °C ... 50 °C
-20 °C ... 75 °C
< 95 % (non-condensing)
IP 50 (with housing)
approx. 10 g
W: 32 mm H: 20 mm D: 10 mm
DoP-20611130701
808624
EOL-O terminating device
1
The EOL-O terminating device is mounted on the last control input device in the detector zone and ​
is used to monitor alarm signaling devices.
4
5
6
7
Features
• Used for monitoring of control outputs with ​
conventional alarm signaling devices being ​
connected
• Additionally recognizes creeping interruptions ​
and short-circuits
• Loop monitoring in compliance with EN 54-13
8
9
808626
EOL-I terminating device
1
The EOL-I terminating device is mounted on the last device in the detector zone and is used to ​
monitor detector zone inputs.
10
11
Features
• Used for monitoring of detector zone inputs with ​
standard fire detectors being connected
• Additionally recognizes creeping interruptions ​
and short-circuits
• Loop monitoring in compliance with EN 54-13
12
13
804870
Alarm and monitoring module for IQ8FCT XS, IQ8FCT LP
1
An external, monitored contact can be connected to the terminals of the IQ8FCT XS or LP. In case
of contact activation, the address and the ​programmed additional text of the corresponding
IQ8FCT XS or LP will be ​displayed.
14
The max. cable length to the connected module must not exceed 500 meters!
133
Transponders / Input & Output Modules
esserbus
Technical Alarm Modules
804868
IQ8TAL with isolator, 1 contact IN/1 OUT
1
Approval: VdS
The technical alarm device IQ8TAL is a fully-fledged loop device of the IQ8Control fire detection ​
system and facilitates the detection and forwarding of technical alarms.
Features
• One contact input and one floating relay output
• Voltage supply via the field bus
• Test and reset function
• Higher IP55 protection with Part No. 704965
• Programmable inverse monitoring functionality ​
of the contact input (1k resistance latent/10k ​
resistance fire)
• Powered by the FACP
• Total cable length of the external contact up to ​
500 m
• Integrated loop isolator
• Max. 127 transponder TAL electronic modules ​
per analog loop
The IQ8TAL is equipped with an integrated loop isolator, a contact input and a relay output. An ​
external NO or NC may be connected to a single IQ8TAL. When an alarm is triggered the address ​
and the programmed additional text of the IQ8TAL to which the contact is connected are displayed ​
automatically. The integrated relay can be optionally configured as a normally-closed contact or as ​
a normally-open contact. The IQ8TAL does not need a separate voltage supply.
In order to increase the IP protection class, the optional IP 55 protection kit (Part No. 704965) can ​
be used.
The functionality of the IQ8TAL can be tested with the included key and the alarm status can be ​
reset directly at the device.
Technical Data
Quiescent current @ 19 V DC
Contact load relay
Operation indicator
Alarm display
Connection terminal
Application temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
Declaration of Performance
approx. 45 μA
30 V DC/AC/1 A
green LED
red LED
max. 2.5 mm² (AWG 26-14)
-20 °C ... 70 °C
-30 °C ... 75 °C
< 95 % (non-condensing)
IP 43, IP 55 with cover 704965
PC/ASA plastic
blue, similar to RAL 5015
approx. 110 g
W: 88 mm H: 88 mm D: 21 mm
W: 88 mm H: 88 mm D: 57 mm (with surface-​
mounted housing)
DoP-20792130701
Please note that for surface mounting, the mount housing (Part No. 704981) must be ordered ​
separately.
Compatible with all IQ8Control systems with firmware V3.08 and tools 8000 V1.14 or ​superior.
2 x 10 k (terminating), 1 x 1 k (alarm), 1 x 6.8 k (inverse operation)
Accessories
704965 Protective kit for MCP and TAL, transparent
704981 Surface mount housing for small MCP, blue
704981
Surface mount housing for small MCP and TAL, blue, similar to RAL 5015
Blue, for small design electronic modules. Cable entry requires cable glands 704147, 704148.
134
www.hls-austria.com
Transponders / Input & Output Modules
704965
esserbus
1
Protective kit for MCP and TAL, transparent
1
Transparent, suitable for small MCPs. The cover serves as a protection to prevent inad­vertent activation and to protect from high humidity.
Technical Data
Type of protection
2
IP55
Cover and two neoprene seals
3
4
5
6
7
8
9
10
11
12
13
14
135
Notes
136
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
11
Wireless Components
Wireless Modules
138-144 12
13
14
137
Wireless Components
Features
• Radiocommunication transmission features
• Interference-proof transmission via dual band ​
with frequency hopping @ 433 MHz and 868 ​
MHz
• Bi-directional data traffic
• Permanent automatic interference monitoring of ​
transmission path
• In case of interferences, automatic modification ​
of frequency band and radiocommunication ​
channel
• Band blocking detection
• High transmission range (in the open air: max. ​
300 m)
• Automatic interference detection due to low field ​
strength levels
Wireless Modules
The following wireless modules are only compatible with IQ8Control panel. Communication ​
between the RF devices is set up via a dual band transmission mode. The RF-technology applies ​
frequency hopping to enable highest transmission security. In case of interference, the frequency ​
band and the radiocommunication channels are automatically modified. If the entire band and the ​
receiver are blocked due to high interference level, a fault signal is transmitted to the fire alarm ​
panel. Thus, secure and reliable wireless transmission is provided.
The transmission range in open air is up to 300 m. Inside the building, the transmission range ​
varies, depending on building structure, wall thickness or use of reinforced concrete.
IQ8Wireless radio technology facilitates the cable-free connection of IQ8Quad automatic fire ​
detectors (with and without alarm signaling devices), manual call points and the IQ8Alarm alarm ​
signaling device to the IQ8Control fire alarm system.
Already existing fire alarm systems can be expanded using the wireless technology or complete ​
fire alarm systems can be realized for smaller objects with wireless components as well.
The allocation of the wireless components to a wireless transponder or wireless gateway takes ​
place via the tools 8000 programming software.
The status of the batteries is checked automatically and their necessary replacement is displayed ​
early on as a detector failure on the FACP and/or the wireless transponder*.
The optimal installation site as well as the maximum possible transmission distance can be ​conveniently and quickly transmitted via the tools 8000 integrated field strength measurement.
* during allocation of the wireless components via wireless transponder
Please take into account that the use of wireless components requires extra training, ​
covering project planning and commissioning. For further information see our training ​
brochure.
These devices were designed, produced and labeled for operation within the countries of the ​
European Union (EU) in accordance with the current EU standards and requirements. In ​
case the device is installed outside of the EU, national guidelines and requirements must be ​
taken into consideration.
For further information, please contact your local sales representative.
Using components like IQ8Alarm and IQ8Quad with integrated alarm devices the esserbus ​
PLus is needed.
max. 32 wireless detectors
max. 10 control groups
12 V DC
esserbus-PLus
max.
10 wireless
call points
Connection example
138
www.hls-austria.com
Wireless Components
805593.10
Wireless Modules
1
IQ8Wireless detector base
1
Approval: VdS
2
With the IQ8Wireless base, the wireless component is located in the base onto which the ​respective fire detector is placed. The wireless base facilitates the connection of the IQ8Quad TM, ​TD, O,
O²T and OTG detectors via a wireless transmission line to the esserbus/esserbus-PLus and ​integrates them via wireless transponder or wireless gateway into the fire alarm system.
A maximum of 32 radio bases per wireless transponder and/or 10 per radio gateway can be alloc­
ated.
Wireless base
135 mm
45
mm
Wireless base with Detector
86
mm
Features
The wireless detector base suitable for
• Fixed heat detector (Part No. 802171, 802177)
• Rate-of-rise heat detector (Part No. 802271, ​
803271)
• Optical smoke detector (Part No. 802371, ​
803371)
• O²T multisensor fire detector (Part No. 802374, ​
803374)
• OTG multisensor fire detector (Part No. 802473)
The wireless detector base features
• Individual detector identification on the control ​
panel
• Regular functionality check for each detector
• Alarm and operation display on the detector
• Alarm and fault transmission in accordance with ​
EN 54-2
• Easy detector or battery replacement with ​
detector removal tool
• Fault signal when the mounted wireless base ​
and the inserted detector are removed
• Permanent monitoring of battery voltage
• Up to 2 years battery life depending on detector ​
type and environmental conditions
Technical Data
Operating voltage
Current consumption
Battery operating time
Range inside
Range outside
Frequency band 1
Frequency band 2
Data transmission speed
Application temperature
Storage temperature
3
4
4 x 3.6 V batteries
approx. 50 µA
approx. 3 years*
max. 30 m
max. 300 m
433 MHz with 16 channels
868 MHz with 7 channels
19.2 Kbit/s
-5 °C ... 55 °C
-20 °C ... 70 °C (w/o batteries)
15 °C ... 35 °C (with batteries)
< 95 % (non condensing)
IP 42
ABS-V0
white, similar to RAL 9010
approx. 315 g (incl. batteries)
EN 54-18:2005/-25:2008
Ø: 135 mm H: 49 mm (with detector H: 88 mm)
DoP-20622130701
Air humidity
Type of protection
Material
Color
Weight
Specification
Dimensions
Declaration of Performance
5
6
7
8
9
The batteries to be used are components of the device approval according to EN 54 and are ​
specified by the manufacturer. With the IQ8Wireless radio components, only the approved ​
batteries with Part No. 805597 may be used. Use of batteries other than those specified by ​
us automatically voids the product’s device approval (VdS-approval) and may not be used for ​
example in Germany in fire alarm systems under legal building regulations.
10
*The battery operating time is dependent on the type of detector/device used, as well as the ​
application temperature and additional surrounding conditions. It can be substantially ​
restricted by increased current consumption of the wireless devices in the case of alarm, ​
wireless interference or poor transmission, or even possibly through contact resistance at the ​
contacts. Please note important instructions for usage of batteries in manual Part No. ​
798941.10 (available at the website).
11
12
4 x 3.6 V lithium batteries (Part No. 805597)
13
Accessories
805597 4 x 3.6 V lithium batteries
Room 1
Room 1
2
1
Room 1
Room 1
14
3
Room 1
Room 1
Expansion via IQ8Wireless gateway with IQ8Wireless detector base
139
Wireless Components
805594.10
Wireless Modules
IQ8Wireless gateway for devices
1
Approval: VdS
Wireless base
135 mm
45
mm
Wireless base with detector
86
mm
Features
• The wireless gateway can be mounted between ​
detector base and IQ8Quad detector. No addi­
tional wiring required
• Suitable for IQ8Quad detectors w/o alarm ​
devices
• The connection of an remote LED indicator for ​
this detector is possible
• Wireless communication with up to 10 users
• Maximum 10 wireless bases
• Maximum 10 wireless interfaces with IQ8MCP ​
manual call points
• Maximum 10 control groups for wireless inter­
face with IQ8Quad/IQ8Alarm alarm signaling ​
devices
• All wireless devices are integrated as individu­
ally addressable on the esserbus / esserbus-​
PLus
• esserbus integration of all radiocommunication ​
devices as individually addressable users
• The radiocommunication devices can be alloc­
ated in up to 10 detector zones
• Up to 9 wireless gateways per loop
• Alarm and trouble transmission in accordance ​
with EN 54-2
• Easy detector or battery replacement via ​
detector removal tool
• Trouble signal when removing the gateway and ​
the detector
• Permanent monitoring of battery voltage
• One gateway requires one loop address
• The total number of loop devices of the loop will ​
be reduced by only 12 devices for each ​
connected IQ8Wireless Gateway
• Max. 18 IQ8Wireless Gateways per FACP ​
IQ8Control C
• Max. 45 IQ8Wireless Gateways per FACP ​
IQ8Control M and FACP FlexES Control
140
www.hls-austria.com
This wireless gateway is especially designed for convenient and time-saving expansion of an ​
already existing IQ8Control/FlexES Control fire detection system. By removing a detector already ​
installed on the loop and adding the wireless gateway to the standard IQ8 detector base, up to 10 ​
additional fire detectors equipped with wireless detector bases or 10 addressable manual call ​
points can be added to the existing system. Up to 10 components with alarm signaling functions – ​
IQ8Alarm alarm signaling devices and/or IQ8Quad fire alarms with integrated alarm signaling ​
device – can be connected per wireless gateway via the universal wireless interface. And all this ​
without any additional cabling. Depending on the surrounding conditions, the wireless transmission ​
can reach up to 200m. The wireless gateway must fundamentally be operated with an IQ8Quad ​
detector. It integrates the intelligent IQ8Wireless components into the esserbus or esserbus-PLus ​
via the wireless base or wireless interface, thus making these components fully individually ​addressable loop devices.
Up to 9 wireless gateways can be operated on the loop. Each wireless gateway reduces the ​
maximum number of esserbus devices by 12 pieces.
Technical Data
Operating voltage
Voltage supply
Current consumption
Battery operating time
Range inside
Range outside
Frequency band 1
Frequency band 2
Transmitter power
Sensitivity
Data transmission speed
Application temperature
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
Specification
Dimensions
Declaration of Performance
8 ... 42 V DC (via loop)
4 x 3.6 V lithium battery
400 µA to max. 2,5 mA
approx. 3 years*
max. 20 m
max. 200 m
433 MHz with 16 channels
868 MHz with 7 channels
10 mW
-100 dBm
19,2 Kbit/s
-5 °C ... 55 °C
-20 °C ... 70 °C (w/o batteries)
15 °C ... 35 °C (with batteries)
< 95 % (non-condensing)
IP 42
ABS
white, similar to RAL 9010
approx. 265 g (incl. batteries)
EN 54-17:2005/-18:2005/-25:2008
Ø: 135 mm H: 49 mm (with detector H: 88 mm)
DoP-20620130701
The standard detector base version IQ8Quad 805590 is not included in the RF gateway ​
package.
The batteries to be used are components of the device approval according to EN 54 and are ​
specified by the manufacturer. With the IQ8Wireless radio components, only the approved ​
batteries with part no. 805597 may be used. Use of batteries other than those specified by us ​
automatically voids the product’s device approval (VdS-approval) and may not be used for ​
example in Germany in fire alarm systems under legal building regulations.
*The battery operating time is dependent on the type of detector/device used, as well as the ​
application temperature and additional surrounding conditions. It can be substantially ​
restricted by increased current consumption of the wireless devices in the case of alarm, ​
wireless interference or poor transmission, or even possibly through contact resistance at the ​
contacts. Please note important instructions for usage of batteries in FB 798941.
4 x 3.6 V lithium batteries (Part No. 805597)
Accessories
805597 4 x 3.6 V lithium batteries
Wireless Components
805595.10
Wireless Modules
1
IQ8Wireless transponder for devices, wall mount
1
Approval: VdS
2
This wireless transponder is designed for wall mounting. The wireless transponder communicates ​
with up to 32 other wireless devices. These can be wireless of various types from intelligent auto­
matic fire detectors or wireless interfaces with manual call points and/or alarm signaling devices of ​
the IQ8-family. Using the System IQ8Control/FlexES Control, the wireless transponder integrates ​
the intelligent automatic detectors (with and without alarm signaling devices), manual call point and ​
alarm generator IQ8Alarm in the esserbus / esserbus-PLus via the wireless base and/or wireless ​
interface. The detector base allows esserbus integration of intelligent automatic detectors as bus ​
devices with individual addressing via the transponder. Up to 10 transponders can be operated on ​
one loop. The transponder can be linked with the loop as well as with a conventional detector zone ​
or it can be operated as a stand-alone unit. Potential-free outputs for common fault and common ​
fire are available. For system 8000 the transponder for RF devices can only be connected by using ​
a potential-free relay to 4 IN/2 OUT or 1 IN transponder, because it is not compatible with panel ​
8000 and it cannot be used as a bus device.
136
mm
280
mm
144
mm
200 mm
39
mm
Features
• RF communication with up to 32 users
• maximum 32 wireless bases
• maximum 10 wireless interfaces with IQ8MCP ​
manual call points
• maximum 10 control groups for wireless inter­
face with IQ8Quad/IQ8Alarm alarm signaling ​
devices
• esserbus integration of all RF. Devices as indi­
vidually addressable users
• The RF devices can be assigned in up to 32 ​
detector zones
• Alarm and fault transmission in accordance with ​
EN 54-2
• Connection to esserbus of IQ8Control panel as ​
bus device as well as to a conventional detector ​
zones
• Stand-alone operation
• Potential-free outputs for common fault and ​
common fire
3
4
5
The transponder needs an external supply voltage for operation.
6
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Alarm current @ 12 V DC
Range inside
Range outside
Frequency band 1
Frequency band 2
Data transmission speed
Contact load relay
Application temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Specification
Dimensions
7
9 ... 30 V DC (via loop)
approx. 17 mA
approx. 18 mA
max. 30 m
max. 300 m
433 MHz with 16 channels
868 MHz with 7 channels
19,2 Kbit/s
30 V DC/1 A
-5 °C ... 55 °C
-10 °C ... 60 °C
< 95 % (non condensing)
IP 42
ASA + PC
white, similar to RAL 9010
approx. 250 g
EN 54-17:2005/-18:2005/-25:2008
W: 200 mm H: 280 mm D: 39 mm (with detector H: ​88
mm)
DoP-20621130701
Declaration of Performance
8
9
10
11
12
The external power supply of the IQ8Wireless transponder can come from the FACP or from ​
an external power unit.
The voltage for the wireless transponder can be supplied by the FACP or an external power ​
supply. An individual, separately protected supply line must be installed for the voltage ​
supply. The external voltage supply is monitored by the wireless transponder. If the wireless ​
transponder is installed as a device on the IQ8Control/FlexES Control, fire system, analog ​
loop, a disturbance is transmitted to the fire detection control unit via the loop and is indicated ​
there.
30 up to 300 m
max. 32 wireless detectors
12 V DC
13
14
Max. 10 control groups
with alarm devices
max. 10 wireless call points
esserbus-PLus
Max. 3 m
141
Wireless Components
805601.10
Wireless Modules
IQ8Wireless universal interface w/o cover, red
1
Approval: VdS
The radio interface allows the IQ8MCP (small or large design) to be connected on the wireless ​
esserbus-PLus.
The radio interface connects the intelligent IQ8MCP to the esserbus/powered loop via the ​IQ8Wireless transponder or the IQ8Wireless gateway. Thus, the devices are automatically ​converted into
individually addressable loop devices.
Features
Radio interface suitable for:
• IQ8MCP - electronic module, large design (Part ​
No. 804905/ 804906)
• IQ8MCP – complete package, small design ​
(Part No. 804971)
• IQ8MCP - electronic module, small design (Part ​
No. 804955), only with mounting frame (Part No. ​
704967)
• IQ8Quad detectors (with and without alarm ​
signaling devices)
• IQ8Alarm alarm signaling device (Part No. ​
8073xx)
Radio interface features:
• The IQ8 components are individually identified ​
on the FACP
• Regular functionality performance checks of IQ8 ​
components
• Fault signal when the IQ8 components are ​
removed from the FACP
• Operating mode display directly at the IQ8 ​
manual call point and IQ8Quad detector
• Alarm and fault message transmission in ​compliance with EN 54-2
• Easy detector removal and battery replacement ​
using multi-functional key
• Remote operation of IQ8 components possible ​
(max. 3 meters) via 2-wire line
• Constant battery status monitoring
• Early battery replacement notification at the ​
FACP
Technical Data
Operating voltage
Current consumption
Battery operating time
Range inside
Range outside
Frequency band 1
Frequency band 2
Data transmission speed
Application temperature
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
Specification
Dimensions
Declaration of Performance
4 x 3.6 V batteries
approx. 30 μA
approx. 3 years*
max. 30 m
max. 300 m
433 MHz with 16 channels
868 MHz with 7 channels
19,2 Kbit/s
-5 °C ... 55 °C
-20 °C ... 70 °C (w/o batteries)
15 °C ... 35 °C (with batteries)
< 95 % (non-condensing)
IP 42
PC/ASA plastic
red, similar to RAL 3020
approx. 285 g (incl. batteries, without attachment)
EN 54-18:2005/-25:2008
W: 135 mm H: 135 mm D: 20 mm (without ​attachment)
DoP-20623130701
Only use small manual call points with mounting frame Part No. 704967.
The batteries to be used are components of the device approval according to EN 54 and are ​
specified by the manufacturer. With the IQ8Wireless radio components, only the approved ​
batteries with Part No. 805597 may be used. Use of batteries other than those specified by ​
us automatically voids the product’s device approval (VdS-approval) and may not be used for ​
example in Germany in fire alarm systems under legal building regulations.
*The battery operating time is dependent on the type of detector/device used, as well as the ​
application temperature and additional surrounding conditions. It can be substantially ​
restricted by increased current consumption of the wireless devices in the case of alarm, ​
wireless interference or poor transmission, or even possibly through contact resistance at the ​
contacts. Please note important instructions for usage of batteries in in manual Part No. ​
798941.10 (available at the website).
4 x 3.6 V lithium batteries (Part No. 805597)
Accessories
704967 Mounting frame for small MCP
805603 IQ8Wireless-mounting frames for IQ8Alarm
805601.10
805602.10
Application example for large MCP
142
www.hls-austria.com
704967
Wireless Components
805602.10
Wireless Modules
1
IQ8Wireless universal interface w/o cover, white
1
Approval: VdS
As 805601.10, but white color.
2
Accessories
704967 Mounting frame for small MCP
805603 IQ8Wireless-mounting frames for IQ8Alarm
805604 IQ8Wireless-mounting frames for IQ8Quad
3
4
704967
Mounting frame for small MCP, red and white
1
The mounting frame is useful for mounting MCPs on different international flush mount boxes.
Technical Data
Color
5
red, similar to RAL 3020
white, similar to RAL 9010
W: 132 mm H: 132 mm D: 8 mm
Dimensions
6
2 x Fastening screws are included (red and white)
7
8
or
9
Application example: Mounting frame with small MCP
10
805603
IQ8Wireless mounting frames for IQ8Alarm, red and white
1
The mounting frame is used for the mounting of the IQ8Alarm alarm signaling devices onto the ​
IQ8Wireless interface Part No. 805601.10/805602.10.
Technical Data
Color
11
red, similar to RAL 3020
white, similar to RAL 9010
approx. 64 g
W: 133 mm H: 133 mm D: 21 mm
Weight
Dimensions
12
13
1 x mounting frame red
1 x mounting frame white
14
=
IQWireless interface +
IQ8Alarm
+
IQWireless interface
805601.10 (red) or
805602.10 (white)
+
Mounting frames
805603
IQ8Alarm devices
8072xx or 8073xx
Application example
143
Wireless Components
Wireless Modules
805604
IQ8Wireless mounting frame for IQ8Quad detectors, white
1
The mounting frame is used for the mounting of the IQ8Quad fire detector with or without integ­
rated alarm signaling device onto the IQ8Wireless interface 805602.10.
Technical Data
Color
Weight
Dimensions
white, similar to RAL 9010
approx. 41 g
W: 133 mm H: 133 mm D: 21 mm
=
IQWireless interface +
IQ8Quad detector with
integrated alarm device
+
+
IQWireless interface
805602.10
Mounting frame
805604
+
Standard detector base
805590
IQ8Quad detector
with integrated
alarm device
80238x
Application example
805605
IQ8Wireless cover for wireless interface, red and white
1
For applications in which the IQ8 components are not to be directly mounted (remote connection) ​
on the IQ8Wireless interface Part No. 805601.10/805602.10, the wireless interface can be used ​
with the filler panel.
Technical Data
Color
red, similar to RAL 3020
white, similar to RAL 9010
approx. 33 g
W: 133 mm H: 133 mm D: 8 mm
Weight
Dimensions
1 x Red cover plate
1 x White cover plate
Max. 10 wireless MCPs
12 V DC
esserbus-PLus
max. loop length 3,5 km
12 V DC
Application example
144
www.hls-austria.com
Operation via
wireless interface and
2-wire connection
(max. 3 meter)
1
2
3
4
5
6
7
8
9
10
11
Detectors for Special Applications
Flame and Heat Detectors
Air Duct Detectors
146-153 12
154-156
Linear Heat Detectors
157-163
Linear Smoke Detectors
164-171
Aspirating Smoke Detectors
172-188
13
14
145
Detectors for Special Applications
Flame and Heat Detectors
Flame Detectors
782311
UV flame detector UniVario
1
Approval: VdS
UV flame detector for the recognition of fast developing fires with flame formation. Operation, fault ​
and fire statuses are displayed via LEDs on the detector. The supply voltage and the linking take ​
place directly via the standard detector zone at the esserbus transponder (part no. 808623.10). ​
Resetting of the detector is also carried out directly via the same esserbus transponder.
Features
• Direct linking and voltage supply via standard ​
detector group at the esserbus transponder ​
(Part No. 808623.10)
• Base installation and alignment via mounting ​
bracket (Part No. 783312)
• High IP protection for indoor and outdoor usage
• Operation and fault status displayed on the ​
detector
• Self-monitoring via internal sensors
• Easy testing with magnet via integrated reed ​
switch
782315
Technical Data
Operating voltage
Quiescent current @ 9 V DC
Alarm current @ 9 V DC
Area to be monitored
Height to be monitored
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
Declaration of Performance
9 V DC
approx. 500 μA
typ. 15 mA
max. 676 m²
max. 45 m
-20 °C ... 80 °C
-40 °C ... 85 °C
< 95 % (non-condensing)
IP 67
Die cast aluminum
red, similar to RAL 3000
approx. 945 g (incl. base and bracket)
W: 130 mm H: 140 mm D: 92 mm
DoP-20567130701
Detector base and mounting bracket are not supplied!
Three-channel infrared flame detector UniVario
1
Approval: G 211041
UniVario three-channel IR flame detector for recognition of quickly developing fires with flame ​
development. Optical windows of the IR sensors are fully monitored. The detector achieves a high ​
level of resistance towards disturbance variables via three-channel infrared evaluation. Voltage ​
supply and connection occur directly via the standard detector zone at the esserbus transponder ​
(Part No. 808623.10). The detector is also reset directly via the same esserbus transponder.
Features
• Direct linking and voltage supply via standard ​
detector group at the esserbus transponder ​
(Part No. 808623.10)
• Base installation and alignment via mounting ​
bracket (Part No. 783312)
• 3-channel infrared flame detector
• High level of protection against disturbance vari­
ables thanks to optimized hardware and devel­
opment of special algorithms
• Maximum level of response sensitivity according ​
to EN54-10, Class 1
• Each optical channel has separate functional ​
monitoring
• Easy testing with magnet via integrated reed ​
switch
146
www.hls-austria.com
Technical Data
Operating voltage
Quiescent current
Alarm current @ 9 V DC
Area to be monitored
Height to be monitored
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
Declaration of Performance
9 V DC
approx. 3.5 mA
typ. 21.8 mA
max. 676 m²
max. 45 m
-20 °C ... 80 °C
-40 °C ... 85 °C
0 ... 95 % (non-condensing)
IP 67
Die cast aluminum
red, similar to RAL 3000
approx. 991 g (incl. base and bracket)
W: 130 mm H: 140 mm D: 92 mm
DoP-21055130701
Detector base and mounting bracket are not supplied!
Detectors for Special Applications
Flame and Heat Detectors
1
Heat Detectors
782310
Heat detector UniVario
2
1
Approval: G 211039
For detection of open fires with fast development of heat. For usage in polluted industrial environ­
ments, interior and exterior areas. Voltage supply and connection occur directly via the standard ​
detector zone at the esserbus transponder (Part No. 808623.10). The detector is also reset directly ​
via the esserbus transponder.
Features
• Direct linking and voltage supply via standard ​
detector group at the esserbus transponder ​
(Part No. 808623.10)
• Base installation and alignment via mounting ​
bracket (Part No. 783312)
• Microcontroller functional monitoring of heat ​
sensors as well as software and hardware
• Quick fire detection with high level of protection ​
against false alarms
• Comparison to typical false variables using intel­
ligent evaluation algorithms
• High level of electromagnetic compatibility
• Various mounting possibilities
• Oil-tight and high level IP 67 protection class as ​
well as resistance to impact and vibration
Technical Data
Operating voltage
Quiescent current
Alarm current @ 9 V DC
Response temperature
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
Declaration of Performance
3
4
9 V DC
approx. 0.15 mA
typ. 15 mA
0 °C ... 90 °C
-20 °C ... 80 °C
-40 °C ... 85 °C
< 95 % (non-condensing)
IP 67
Die cast aluminum
red, similar to RAL 3000
approx. 995 g (incl. base and bracket)
W: 130 mm H: 140 mm D: 85 mm
DoP-21053130701
5
6
7
Detector base and mounting bracket are not supplied!
8
9
10
782302
Heat detector UniVario, 200 mm
1
Approval: G 211040
11
Same as 782310, but with sensor rod length of 200 mm.
Technical Data
Quiescent current
Response temperature
Weight
Declaration of Performance
12
approx. 0.25 mA
54 °C ... 400 °C
approx. 1 kg
DoP-21054130701
13
Detector base and mounting bracket are not supplied!
14
147
Detectors for Special Applications
Flame and Heat Detectors
782306
Heat detector UniVario, 2 m
1
Same as 782310, but with sensor tube for installation in areas with poor accessibility such as ​
shafts and canals.
Technical Data
Response temperature
Weight
54 °C ... 400 °C
approx. 1.3 kg
Detector base and mounting bracket are not supplied!
782307
Heat detector UniVario, 6 m
Same as 782306, but with sensor tube length of 6 m.
Technical Data
Weight
approx. 1.4 kg
Detector base and mounting bracket are not supplied!
782308
Heat detector UniVario, 9 m
Same as 782306, but with sensor tube length of 9 m.
Technical Data
Weight
approx. 1.5 kg
Detector base and mounting bracket are not supplied!
Accessories
783312
Mounting bracket for UniVario flame detectors
1
Mounting bracket for alignment of the industrial flame detectors UniVario. Simple installation with ​
base Part No. 783313.
783313
Standard base UniVario
1
Standard detector base for detectors of the UniVario product family.
Technical Data
Weight
Dimensions
Features
• Simple detector exchange via standard base ​
principle
• Fast installation via simple plug-in
• Generous space for cabling for user-friendly ​
installation
148
www.hls-austria.com
approx. 350 g
W: 130 mm H: 140 mm D: 36 mm
Detectors for Special Applications
Flame and Heat Detectors
1
Intrinsically Safe Flame Detectors
FS24X-911-23-6
1
FS24X-911 3IR AL M25 FM/EN54
2
The FS24X multi-spectrum Triple IR (IR/IR/IR/Visible) Flame Detector, is one of the FSX family of
advanced technology Electro-Optical fire and flame detectors. WideBand IR™, WideBand 4.3
micron IR™, and Visible detection technology with sophisticated software algorithms delivers the
highest fire detection performance combined with optimal false alarm rejection. Unlike narrow-band
detectors, the WideBand IR™ Infrared technology using high-speed solid-state Quantum sensors
allows detection of most types of fires, hydrocarbon and non-hydrocarbon, in all weather
conditions.
3
4
FS24X - Aluminium, M25, ATEX/IECEx, FM3260, EN54-10.
Advanced true triple IR Flame Detector for Hazardous Industrial areas.
Features
• Patented WideBand IR™ technology
• Patented Electronic Frequency Analysis™
• Visible sensor for optimum false alarm rejection
• Selectable detection sensitivities
• Field-of-View: 90° cone-of-vision
• Dual microprocessors for reliable performance
• Real-time clock for accurate time dating of
events
• FirePic™ — pre-fire event data storage
• Event log with date and time stamp
• RS-485 ModBus communication
• Non-Isolated 4-20 mA Analog output (sink or
source)
• Alarm, Fault and Fire Verification relays
• Automatic Optical Path and Electronic self-test
Technical Data
Operating voltage
Field of view
Sensitivity
Response time
Power Consumption
Output Relays
• Patented Electronics Module for component
protection with plug-in terminations for easy field
installation
• Two M25 conduit entries
• Low power consumption
• High RFI and EMI immunity
• FM, ATEX, CE mark approvals
• CU-TR approved
• INMETRO approved
• Meets SIL 2 requirements
• Certified to EN54-10:2002
• FM 3260 performance
• Detects hydrocarbon and non-hydrocarbon fuel
fires in all environmental conditions
• Wide operating temperature range
• Optimal false alarm rejection
• Minimal maintenance for trouble-free operation
• PC software and interface module (FSIM) for
fault diagnostics real-time graphs (RTGs), and
downloading of FirePics™ and event log
• Suitable for a wide variety of applications
• Easy electronics module replacement
• Test lamps for manual testing
FS24X-211-24-6
5
Visual Indicators:
Green LED: Power; Red LED: Alarm; Yellow LED: Fault
Analog output
Loop resistance
Tempetarure range
Vibration
Wiring
Conduit entries
Dimensions
Housing
6
24 Vdc nominal (18-32 Vdc) - regulated
90° cone of vision, ± 45° from on axis
Very high (60m), high (45m), medium (30m) and low
(15m) - switch selectable
3-5 Seconds to 0.1 m2 (1 sq. ft.) n-Heptane fire at 30
m (100 ft.)
3-10 Seconds to 0.1 m2 (1 sq. ft.) n-Heptane fire at
60 m (200 ft.)
Operating: 56 mA @ 24 Vdc nominal
Alarm: 106 mA @ 24 Vdc nominal
Heater: 155 mA – additional
Note: Heater will turn on at -17ºC (0ºF)
Fire Alarm: SPDT (NO / NC) – De-energised/energized, latching/non-latching
Fault: SPST (NO) – De-energised, latching/
non-latching
Auxiliary: SPDT (NO / NC) – De-energised/energised,
latching/non-latching
Contacts rating: 1 amp @ 24 Vdc
0 - 20 mA stepped - source or sink user selectable
50 - 400 Ohms
Operating: -60°C to +85°C (-76°F to +185°F)
Storage: -55ºC to +110ºC (-67ºF to +230ºF)
Meets or exceeds MilSpec 810C Method 514.2,
Curve AW12
2.5 mm2 (14 AWG) to 0.326 mm2 (22 AWG); shielded
cable recommended
Two M25 conduit entries
W: 110,4 mm H: 124,2 mm D: 156,4 mm
Copper-free powder coated aluminum
7
8
9
10
11
12
13
14
Mounting bracket SM4 and cable glands FSX-25M25 have to be ordered separately.
Accessories
SM4 Stainless Steel Swivel mounting assembly for FS24X, and FS20X detectors
PSU-12 Universal charger for Test Lamps and Interface Kits. For 110-240 VAC with international
plugs
TL-2055 IR Test Lamp for testing FSX detectors, explosion proof version. Incl universal charger
TL-1055 IR Test Lamp for testing FSX detectors, non-explosion proof version. Incl universal
charger
SH-001 Sunshield (316 Stainless Steel)
FSX-25M25 Cable gland
FS24X-911 3IR SS M25 FM/EN54
As FS24X-911-23-6 but 316 stainless steel.
149
Detectors for Special Applications
FS20X-211-23-6
1
Flame and Heat Detectors
FS20X-211 IR/UV AL M25 FM/EN54
Based on the foundation of the highly successful and reliable SS4 detector, the FS20X detector
represents a quantum leap in integrating Infrared and Ultraviolet sensing technologies. The FS20X
is a multi-spectrum UV/Dual IR/VIS fire and flame detector with a proven UV solar-blind sensor.
The FS20X detector uses advanced algorithms for signal processing and fire and flame analysis
to alarm to most fires in all industrial environmental conditions. If the detector’s UV signal is
degraded due to heavy smoke or a contaminated lens, the FS20X’s patented WideBand IR™,
Near Band IR and Visible sensors will still alarm to fire, albeit at a reduced sensitivity and slower
response time.
Features
• Patented WideBand IR™ Infrared combined
with Ultraviolet
• Detection range greater than 60 m (200 feet) to
0.1 m2 (sq. ft.) heptane fire
• Patented Electronic Frequency Analysis
• Visible sensor for optimum false alarm rejection
• Selectable detection sensitivities
• Solar blind 90° field of view
• Dual microprocessors for reliable performance
• Real-time clock for accurate time dating of
events
• FirePic™ — Up to 6 pre-fire event data storage
• Event log — Up to 200 events with date and
time stamp
• Built-in RS-485 ModBus communication
• Built-in non-isolated 4-20 mA analog output (sink
or source)
• Alarm, Fault and Fire Verification relays
• Automatic Optical Path and Electronic self-test
• Patented Electronics Module for component
protection with plug-in terminations for easy field
installation
• Two M25 conduit entries
• Low power consumption
• High RFI and EMI immunity
• FM hazardous area approved
• Ex d ATEX /IECEx approved
• CU-TR approved
• INMETRO approved
• Meets SIL 2 requirements
• Certified to EN54-10:2002
• FM 3260 performance
• Detects hydrocarbon and non-hydrocarbon fuel
fires in all environmental conditions
• Wide operating temperature range
• Arc welding immunity
• False alarm rejection
• Minimal maintenance for trouble-free operation
• PC software and interface module (FSIM) for
fault diagnostics real-time graphs (RTGs), and
downloading of FirePics™ and event log
• Suitable for a wide variety of applications
FS20X-211-24-6
The FS20X detector has a detection range in excess of 60 m (200 feet) (very high sensitivity
setting) for the detection of a 0.1m2 (one square-foot) n-Heptane reference fire and has a field of
view with a greater volumetric coverage than most UV/IR detectors.
FS20X - Aluminium, M25, ATEX/IECEx, FM3260, EN54-10.
Advanced UV/Dual IR/VIS Flame Detector for Hazardous Industrial areas.
Visual Indicators:
Green LED: Power; Red LED: Alarm; Yellow LED: Fault
Technical Data
Operating voltage
Field of view
Sensitivity
Response time
Power Consumption
Output Relays
Analog output
Loop resistance
Tempetarure range
Vibration
Wiring
Conduit entries
Dimensions
Housing
24 Vdc nominal (18-32 Vdc) - regulated
90° Horizontal Cone of vision, ± 45° from on axis
Very high (60m), high (45m), medium (30m) and low
(15m) - switch selectable
3-5 Seconds to 0.1 m2 (1 sq. ft.) n-Heptane fire at 30
m (100 ft.)
3-10 Seconds to 0.1 m2 (1 sq. ft.) n-Heptane fire at
60 m (200 ft.)
24 Vdc nominal (18-32 Vdc) - regulated
Fire Alarm: SPDT (NO / NC) – De-energised/
energized, latching/non-latching
Fault: SPST (NO) – De-energised, latching/
non-latching
Auxiliary: SPDT (NO / NC) – De-energised/energised,
latching/non-latching
Contacts rating: 1 amp @ 24 Vdc
0 - 20 mA stepped - source or sink user selectable
50 - 400 Ohms
Operating: -40 to +85ºC (-40 to +185ºF)
Storage: -55 to +110ºC (-67 to +230ºF)
Meets or exceeds MilSpec 810C Method 514.2,
Curve AW12
2.5 mm2 (14 AWG) to 0.326 mm2 (22 AWG); shielded
cable recommended
Two M25 conduit entries
W: 110,4 mm H: 124,2 mm D: 156,4 mm
Copper-free powder coated aluminum
Mounting bracket SM4 and cable glands FSX-25M25 have to be ordered separately.
Accessories
SM4 Stainless Steel Swivel mounting assembly for FS24X, and FS20X detectors
PSU-12 Universal charger for Test Lamps and Interface Kits. For 110-240 VAC with international
plugs
TL-2055 IR Test Lamp for testing FSX detectors, explosion proof version. Incl universal charger
TL-1055 IR Test Lamp for testing FSX detectors, non-explosion proof version. Incl universal
charger
SH-001 Sunshield (316 Stainless Steel)
FSX-25M25 Cable gland
FS20X-211 IR/UV SS M25 FM/EN54
As FS20X-211-23-6 but 316 stainless steel.
150
www.hls-austria.com
Detectors for Special Applications
Flame and Heat Detectors
1
FSL100 Series Flame Detectors
Features
• Indoor & outdoor use
• Range of UV. UVIR, IR3
• Zone 2/22 Ex proof
• Hydrocarbon and non-hydrocarbon sources
• Pressure compensation element, avoiding
trapped moisture
• Lightweight GRP housing with no grounding
required
• mA output
• Relay output
• Selection of relay set-up with DIP switches
• Ease of installation
• Swivel mounting with fine angle adjustment
• Light Mounting Bracket
• Entry Gland
• Advanced Test Lamp available
Approval: VdS, ATEX
2
The FSL100 Series of flame detectors from Honeywell delivers robust, fast and reliable detection
of flaming fires in a wide range of applications. The range consists of UV, UVIR and IR3 flame
detectors. All utilise sophisticated sensing and signal analysis to detect fires quickly while also
rejecting false alarms. The FSL100 may be small and lightweight for easy installation but they are
designed to work in tough environments both in and out of doors as well as potentially explosive
atmospheres. With a large field of view they can detect a range of different types of fire including
hydrocarbon and non hydrocarbon sources.
3
4
Available in UV, UVIR and 3IR to cover a wide range of industrial flame detection needs (please
review applications sheet).
5
Visual Indicatiors:
Continuous green: normal operation
Continuous yellow: fault
Flashing yellow: Fault and guide to repeat self-test after a self-test failure
Continuous red: alarm
Technical Data
Range
Cone of vision
Operating voltage
Start up times
Alarm response time
Alarm output settings
Automatic & manual Self-Test
Operating current normal @ 24 V DC
Current in alarm @ 24 VDC
Housing
Dimensions
Weight
Temperature, operating
Typ of protection
Detector specification
EC-type examination certificate
6
7
max. 35 m (IR3), 25 m (UV, UV/IR) alarming within 10
sec. to a 0.1 m2 n-heptane fire
8
90˚minimum horizontal and vertical
10 ... 28 V DC (12 ... 24 V DC nominal)
<10 sec
8 ... 30 sec
Selectable LEDs and relays latching/non-latching;
factory setting: latching
Automatic Sensor Test (built in Self-Test) and manual
Self-Test
approx. 25 mA
approx. 75 mA
Glass Reinforced Polyester (GRP), Non-incendive.
UV resistant, Self-Extinguishing V–0 (UL-94)
H: 125 mm x W: 80 mm x D: 57 mm
465 g
- 40 ˚C ... +70 ˚C
IP65
EN54-10, FM3260
ATEX Zone2/22, FM Class 1, 2 & 3 Div2
9
10
11
12
13
Accessories
FS1000-SM21 FSL100 Swivel mount.
FSL100-TL FSL100 Test lamp, incl. universal charger and carrying case; non EX
FSL100-IR3
14
IR3 flame detector RED, ATEX FM EN54
FSL three-channel IR flame detector for recognition of quickly developing fires with flame development. The detector achieves a high level of resistance towards disturbance variables via threechannel infrared evaluation. It is suitable for most light industrial applications, storage areas and
machinery. It is simple to install with Wide Field of View Solid 90 degree volume cone (Cone of
Vision - Field of View), Long Range; 30m @ 10 sec for 0,1 m² n-Heptane reference fire and both
automatic and manually initiated self-test. IP65 housing is made of Glass Reinforced Polyester
(GRP). It is non-incendive, UV resistant, Self-Extinguishing V–0 (UL-94). Has proven exceptional
resistance against acids, bases and solvents.
151
Detectors for Special Applications
FSL100-UV
Flame and Heat Detectors
UV flame detector RED, ATEX FM EN54
FSL UV flame flame detector for recognition of quickly developing fires with flame development.
The detector achieves a high level of resistance. It is designed for cold storages, fume hoods,
heating rooms for chemicals, isolators and radio amplifier rooms. Detector is simple to install with
wide field of view, solid 90 degree volume cone, Long Range; 25m @ 10 sec for 0,1 m² n-Heptane
reference fire and both automatic and manually initiated self-test. IP65 housing is made of Glass
Reinforced Polyester (GRP), it is non-incendive, UV resistant, Self-Extinguishing V–0 (UL-94).
GRP housing of FSL has proven exceptional resistance against acids, bases and solvents.
FSL100-UVIR
flame detector RED, ATEX FM EN54
FSL-UV/IR flame detector for recognition of quickly developing fires with flame development. The
detector achieves a high level of resistance. It is designed to be used in chemical storages, electric
power transformers, fuel and plug-in hybrid stations, hydrogen storages and laboratories. Detector
is simple to install with wide field of view, solid 90 degree volume cone, Long Range; 25m @ 10
sec for 0,1 m² n-Heptane reference fire and both automatic and manually initiated self-test. IP65
housing is made of Glass Reinforced Polyester (GRP), it is non-incendive, UV resistant, Self-Extinguishing V–0 (UL-94). GRP housing of FSL has proven exceptional resistance against acids,
bases and solvents.
Accessories for Intrinsically Safe Detectors
DASA6-N
Air shield assembly 6MM
FSX Air shield assembly protects the detector window from contaminants/dust.
SM4
Swivel mount
FSX - Universal Swivel Mount allows simple, robust and accurate mounting and sighting of FSX
flame detectors. Supplied in Stainless Steel with angle markings to allow setting detector aiming.
FSX-A001
FSX kit with Interface, RS485,USB cables
Interface kit to enable access to detection logs and FirePics for post event analysis.
152
www.hls-austria.com
Detectors for Special Applications
TL-1055
Flame and Heat Detectors
1
Test lamp FS18X/FS20X/FS24X NON-EXP
FSX Safe Area Test Lamp for in-situ testing of flame detectors.
2
3
4
TL-2055
Test lamp FS18X/FS20X/FS24X EXP
5
FSX Hazardous Area Test Lamp for in-situ testing of flame detectors.
6
7
8
PSU-12
110/220VAC wallcharger test lamp
Charger for FSX test lamp
9
10
SH-001
Sun shield SS SS2/SS4/FS24X
FSX Sunshield protects against direct sun.
FSL100-SM21
11
12
FSL100 swivel mount
FSL100 Swivel mount enabling simple installation and aiming of the FSL100 range of flame
detectors.
13
14
FSL100-TL
FSL100 test lamp, charger & case; non EX
FSL100 Safe Area Test lamp to enable simple in-situ testing of the FSL100 range of flame
detectors.
Accessories
FSL100-TLBT 12 VDC battery for FSL-TL test lamp
FSL100-TLCH Universal charger for FSL-TL test lamp
153
Detectors for Special Applications
Air Duct Detectors
Air Duct Detectors
781443
Venturi air duct module for IQ8Quad OTblue-LKM (802379)
1
Ventilation air duct module for usage of the OTblue-LKM Part No. 802379 air duct smoke detector ​
in combination with Venturi tubes Part No. 781446, 781447 or 781448. The module is mounted on ​
the outside of the air ducts.
The Venturi tube enters the duct and leads the air out of the duct through the detection chamber of ​
the detector back to the duct and finally back into the duct. During operation, the detector and the ​
alarm LED is visible so that an external parallel detector indicator is not required.
The housing need not be opened for maintenance purposes. Inspection of the detector be ​
performed quickly and easily via a separate opening in the front of the housing.
Features
• Single-tube air analysis system based on the ​
Venturi principle
• Optimum utilization of air flow velocity through ​
new Venturi tube design
• Integrated maintenance opening in the front ​
cover so that air duct smoke detector can be ​
tested
• Suitable for air duct widths from 0.6 to 2.8 m
• Integrated air flow display
Technical Data
Type of protection
Housing
Color
Weight
Dimensions
IP 54
ABS plastic
gray
approx. 800 g
W: 180 mm H: 235 mm D: 183 mm
Construction kit includes pipe gasket and cap. The following items are not included: IQ8Quad OTblue ​
LKM or detector base as well as the Venturi tube or filter cartridge.
Correct diameter
calculation dh:
Correct assembly site
Turnaround of
air flow
H
Air flow
W
d h = 2 x Hx W
H+W
5d
Air intake e.g.
Air outlet e.g.
Air flow
D
dh = D
Application example with detector
154
www.hls-austria.com
5d
5d
Mounting on air ducts with
mounting kit
Part No.781449
Detectors for Special Applications
Air Duct Detectors
1
Accessories
802379
OTblue-LKM multisensor fire detector IQ8Quad with isolator
2
1
Approval: VdS
3
Specially addressable IQ8Quad multisensor fire detector with integrated optical sensor and heat ​
sensor and enhanced false alarm management. For application as air duct smoke detector in ​
venturi air duct modules Part No. 781443. The optical measurement chamber is provided with a ​
patented developed sensor technology using a high-sensitive blue LED (instead of the commonly ​
used red LED in Optical smoke detectors), enabling the detection of open fires, smoldering fires ​
and fires with high heat generation.
Especially for open fires, the classical ionization technology implemented in ionization detectors is ​
replaced by the unique detection technology, unlike ionization detectors, this sensor works without ​
a radioactive element which causes problems at the time of refuse disposal. The detector is ​
capable of identifying the TF1 and TF6 test fires described in the EN 54-9:1982 specification. Well ​
suited for sensitive environment, detection of invisible up to large aerosols.
The OTblue multisensor is an intelligent detector with time-related signal analysis, signal correla­
tion of the sensor data, decentralized intelligence, automatic function self-test, CPU failure mode, ​
automatic adaptation to environmental conditions, alarm and operating data memory, alarm indic­
ator and soft-addressing.
The detector is provided with an integrated isolator and a parallel detector indicator can be ​
connected.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Quiescent current @ FACP battery
Air speed
Application temperature
Storage temperature
Air humidity
Type of protection
Housing
Weight
Detector specification
Specification
Dimensions
Declaration of Performance
4
5
6
7
8
9 ... 42 V DC
approx. 50 μA
approx. 200 μA @ 27,5 V
approx. 280 μA @ 42 V
1 ... 20 m/s
-20 °C ... 50 °C
-25 °C ... 75 °C
< 95 % (non condensing)
IP 43 (with base + option)
ABS plastic, white, similar RAL 9010
approx. 110 g
EN 54-7
EN 54-7/-17, CEA 4021
Ø: 117 mm H: 62 mm (incl. base)
DoP-20116130701
9
10
11
12
Only suitable for application in air duct construction set 781443.
Accessories
805590 Standard detector base for IQ8Quad
805591 Detector base with relay contact for IQ8Quad
13
781444
Filter cartridge for air duct module 781443
14
1
For use in unclean environmental conditions.
155
Detectors for Special Applications
Air Duct Detectors
781446
Venturi tube for IQ8Quad air duct construction set 781443, 0.6 m
1
Venturi tube 0.6 m for application with air duct construction set Part No. 781443 between 140 mm ​
and 600 mm.
Technical Data
Material
aluminum
Required borehole in the duct: 38 mm
781447
Venturi tube for IQ8Quad air duct construction set 781443, 1.5 m
1
Venturi tube 1.5 m for application with air duct construction set Part No. 781443 between 600 mm ​
and 1400 mm.
Technical Data
Material
aluminum
Required boreholes in the duct: 38 mm below and 50 mm above.
Venturi tube, plastic gasket and rubber seal
781448
Venturi tube for IQ8Quad air duct construction set 781443, 2.8 m
1
Venturi tube 2.8 m for application with air duct construction set Part No. 781443 between 1400 mm ​
and 2700 mm.
Technical Data
Material
aluminum
Required boreholes in the duct: 38 mm below and 50 mm above.
Venturi tube, plastic gasket and rubber seal
781449
Mounting set for round and insulated air ducts
1
Mounting set for mounting the Part No. 781443 air duct construction set to round and / or insulated ​
air ducts.
Venturi tube, plastic gasket and rubber seal
781445
Weather protection housing for air duct construction set 781443
1
Protects the air duct detector in difficult environmental conditions such as during use in outside ​
areas.
The weather resistant housing can be subsequently fixed above the already mounted and installed ​
air duct module Part No. 781443.
Technical Data
Type of protection
Material
Weight
Dimensions
Opened condition
156
www.hls-austria.com
IP 65
galvanized steel
approx. 1.8 kg
Ø: 282 mm H: 280 mm
Detectors for Special Applications
Linear Heat Detectors
1
Honeywell DTS Detector
1
Approval: VdS, UL, ATEX, LPCB
Features
• Multicolor LCD display
• LED indicators: Alarm, Measurement, Fault, Operation
• Temperature measurement and monitoring via fiberoptic sensor cable (Part No. ​970150.IN or 970153.IN)
2
DTS (Distributed Temperature Sensing) System is capable of detecting fires and accurately locate
spots of the fire. The system allows to precisely measure, locate and signalize already small
differences of temperature changes by measuring and highlighting temperature of a specific spot
vs. environment. Fire resistant (PH category) sensing cable is capable to take signals also during a
fire, even when temperatures are up to 750°C (max. two hours). That allows to monitor the
progress of fire and supervise fire rescue action accordingly.
3
The system can work as a standalone system or be easily integrated into existing management
platforms (e.g. SCADA ​systems) by either communicating directly over Ethernet (TCP/IP) using
SCPI (standard ​commands for programmable instruments) or Modbus (IP or RTU).
4
5
• 1, 2 or 4 measurement channels per evaluation unit
• Loop or open line sensor cable topology
• Up to 256 independent alarm zones per channel
• Up to 10 km sensor cable for each channel
• Laser power below 20 mW
• 10 seconds measurement cycles
• Spatial resolution 0.5 m
• Relay interface, optionally Modbus IP/RTU
Technical Data
Operating voltage
Power consumption
Operating temperature
Storage temperature
Air humidity
Type of protection
Weight
Dimensions
970120.IN
Line heat detector Honeywell DTS - evaluation unit, distance range 1 km
10 ... 30 V DC
approx. 17 W @ 20 °C ambient temperature
-10 °C ... 60 °C
-40 °C ... 80 °C
< 95 % (non condensing)
IP30
approx. 9 kg
W: 448 mm H: 88 mm D: 364 mm 2 HU, 19"
6
7
8
Evaluation unit in a 19" rack mount housing.
970121.IN
9
Line heat detector Honeywell DTS - evaluation unit, distance range 2 km
As 970120.IN, but with a 2 km detection range.
970123.IN
10
Line heat detector Honeywell DTS - evaluation unit, distance range 4 km
As 970120.IN, but with a 4 km detection range.
11
970124.IN
Line heat detector Honeywell DTS - evaluation unit, distance range 6 km
As 970120.IN, but with a 6 km detection range.
12
970125.IN
Line heat detector Honeywell DTS - evaluation unit, distance range 10 km
As 970120.IN, but with a 10 km detection range.
970134.IN
13
Wall mount housing IP66 for Honeywell DTS detector
Approval: VdS, UL, ULC
14
Alternative IP66 wall mount housing with window for 97012X.IN rack housings.
Technical Data
Operating temperature
Storage temperature
Air humidity
Type of protection
Weight
Dimensions
Specification
-10 °C ... 60 °C
-40 °C ... 80 °C
< 95 % (non condensing)
IP66
approx. 17 kg
W: 400 mm H: 500 mm D: 150 mm
EN54-22 (VdS) / UL 521 and ULC-S530
4 x Pflitsch UNI Dicht cable glants
157
Detectors for Special Applications
Linear Heat Detectors
Accessories
970129.IN
Modbus TCP/IP interface for Honeywell DTS detector
Features
• Modbus TCP slave
• Full temperature trace
• Trace index
• Timestamp
• Alarm status
• Zone temperature values (max., min. and avg.)
970130.IN
Optional 2nd sensor channel for Honeywell DTS detector
The DTS evaluation unit is delivered as one channel device as a standard. By ordering 970130.IN
the evaluation unit can be expanded by one additional channel. Two channel option enables to
make a redundant loop.
970132.IN
Option for 4 sensor channel for Honeywell DTS detector
The DTS evaluation unit is delivered as one channel device as a standard. By ordering 970132.IN
the evaluation unit can be expanded by three additional channel. Four channel option enables to
make a full redundant loop.
970133.IN
Extention ATEX approval for Honeywell DTS detector
970166
DTS evaluation unit warranty extention, 3 years
Extended warranty extends the standard warranty period to 3 years. Warranty is applicable to one
evaluation unit purchased together with the warranty. One warranty always covers one evaluation
unit.
970167
DTS evaluation unit warranty extention, 5 years
As 970166 but with a 5 year period.
970135
DTS interface box
1
The DTS system can easily be integrated into SCADA systems, direct process control or ​external
connections to fire control panels. The DTS interface box provides access via the ​Modbus protocol
RS 232, RS 422 and RS 485, as well as TCP/IP. Through a virtual host ​concept the data is available for each sensor (channel) as a Modbus unit. Meaning only ​one unit is required even for
multiple channel operation. 10000 register holdings and 3000 ​register coil definitions can be assigned flexibly to each Modbus unit.
Features
• Modbus: RTU or IP
• Entire temperature trace data
• Independent alarm parameter per zone
• Several status conditions such as fiber break
• LAN: Ethernet 10/100 Mbps, RJ 45
• Serial Interface: RS-232/422/485, DB9 male
158
www.hls-austria.com
Technical Data
Operating voltage
Ambient temperature
Storage temperature
Air humidity
Weight
Dimensions
12 ... 48 V DC
-10 °C ... 60 °C
-20 °C ... 80 °C
5% to 95% (non condensing)
approx. 200 g
W: 111 mm H: 77 mm D: 26 mm
Detectors for Special Applications
970138
Linear Heat Detectors
Relay controller set for Honeywell DTS detector
1
If the application requires driving more than the embedded 20 relay outputs of Honeywell DTS
detector, the relay controller set should be used. The set is capable of controlling up to 256 additional relay outputs per channel. Each relay output can be assigned flexibly to any defined alarm
condition.
2
1
Technical Data
Operating voltage
Current consumption @ 24 V DC
Ambient temperature
Storage temperature
Air humidity
Weight
Dimensions
24 V DC
approx. 350 mA (Controller)
0 °C ... 55 °C
-25 °C ... 85 °C
5% to 95% (non condensing)
approx. 200 g
W: 55 mm H: 100 mm D: 70 mm (Controller)
3
4
1 x power supply
1 x pre-programmed relay controller
1 x digital output module
1 x end module
8 x relays with accessories for easy wiring
970137
5
6
Relays extension set for Honeywell DTS detector
7
The Relays Extension Set adds another digital output module and 8 relays. For example, to ​offer
48 relays, 1 relay controller (Part No. 970138) and 5 Relays Extension Sets are necessary.
Technical Data
Operating voltage
Current consumption @ 24 V DC
Ambient temperature
Storage temperature
Air humidity
8
24 V DC
approx. 25 mA (each IO card/relay)
0 °C ... 55 °C
-25 °C ... 85 °C
5% to 95% (non condensing)
9
1 x Digital output module
8 x Relays output with accessories for easy wiring
10
11
12
13
14
970139
High dense I/O interface set for Honeywell DTS detector
Cable connection set to connect evaluation unit relay outputs with fire alarm system.
1 x input cable, D-Sub 9, 230 cm
1 x 9 pin connnection box
2 x output cable, D-sub 44, 230 cm
2 x HD connection box
159
Detectors for Special Applications
Linear Heat Detectors
Sensor Cables for Honeywell DTS Detector
970150.IN
FO sensor cable Safety FRNC
1
Fast responding sensor cable with tight buffered fiber. Compact dimensions, high flexibility ​and
good bending behaviour. High tensile strength by Aramid yarns. The cable has a ​halogen-free and
flame-retardant cable sheath.
Technical Data
Explosion protection
Material
Weight
ATEX 1 GD, 111/112
FRNC outer sheath, Armid fibers, thight-buffered
fibers
approx. 17 kg /km
Sensor cable will be delivered in requested length.
970153.IN
FO sensor cable Steel FRNC
1
Fast responding sensor cable armoured, with stainless steel loose tubes and outer sheath. ​High
permissible tensile strength, high crush resistance. Longitudinally and laterally water­tight. Excellent
rodent protection. The cable has a halogen-free and flame retardant cable ​sheath.
Technical Data
Explosion protection
Material
Weight
ATEX 1 GD, 111/112
FRNC outer sheath, stainless steel wires, gel-free ​
stainless steel loose tube, fibres with primary coating
approx. 25 kg /km
Sensor cable will be delivered in requested length.
970151
Sensor cable connectors for FO sensor cable 970150.IN
To reduce deployment cost and tim, we are optionally offering preassembled pig tails. This ​enable
quick and easy onsite installation, with no need to organize a fusion splicer, splice ​box to get the
sensing cable connected to the DTS detector. Pig tails are supplied with ​E2000 8° angled connectors. For safe transportation and installation the connectors and ​pig tails are covered by a flexible
tube to ensure proper protection.
2x Connectors
970154
Sensor cable connectors for FO sensor cable 970153.IN
As 970151, but for FO sensor cable steel FRNC (Part No. 970153.IN).
970151.IN
Sensor cable testing tool
The testing tool is used to verify fanctionalty of the sensor cable according to regional requirements.
Electronic boards control the heating sleeves to simulate a fire condition along the fiber-optic
sensor cable. Protection devices are built-in for safe operation. Electrical connections are carried
out by flexible cables, which are protected against mechanical damages by a resistant outer jacket.
The flexible cables have specific plugs for easy connection to the control circuit.
It is possible to use this tool without disassembling the installed mounting brackets (when the
distance is at least 1m).
Features
• 4 LEDs: e.g. Power supply ON, fault signal
• Integrated timer (1 to 10 min)
• User friendly operation
• Work with all fiber-optic cables
160
www.hls-austria.com
Technical Data
Power supply
Current consumption @ 24 V DC
Power consuption
Weight
Dimentions
230 V AC, 50 Hz
max. 1.5 mA
max. 350 W
approx. 1 kg (control unit)
approx. 2 x 1 kg (heating sleeves)
W: 350 mm H: 170 mm D: 440 mm (carrying case)
W: 160 mm H: 80 mm D: 240 mm (control unit)
Detectors for Special Applications
970154.IN
Linear Heat Detectors
1
E2000 APC 8° pigtail, 5 m
1
E2000 8° angled connectors with a 5 m pigtail offered to splice the sensing cables.
2
3
4
970161
E2000 APC adapter to connect two connectors 970154.IN
1
Used to connect two E2000 APC (Part No. 970154.IN) connectors.
5
6
970165.IN
Cutting tool for FO steel sensor cable 970153.IN
7
1
Recommended to cut the stainless steel tube, to properly remove the cable sheath and ​splicing the
pigtail to the sensing fiber.
8
9
10
11
12
13
14
161
Detectors for Special Applications
Linear Heat Detectors
Anchors for Honeywell DTS Detector
970140.IN
Steel anchor with plastic clamp for Honeywell DTS cables
1
Features
• For indoor and outdoor applications
• Applicable for dynamic loads
• UV-stabilized: 5 times better than PA6/PA66
• Very low moisture absorption
• High chemical resistance
• Halogen free as per IEC-Norm 754-2
Self-locking plastic cable clamps with zinc-plated steel anchor, ideal for installation on ​concrete
walls and ceilings. With this mounting solution the sensor cable is fast and ​securely installed. This
plastic cable clamp provides excellent resistance against corrosive ​and chemical atmospheres as
well as an uncritical characteristic relating to fire (halogen ​free). The plastic cable clamp in combination with the metal free cable is especially suitable ​for use in rail tunnels where metal free
components are often required.
To fix the clamps on the concrete a special concrete dowel type is used. The metal dowel is ​an
anchor made of steel, which is placed into a drilled hole and anchored by deformation-​controlled
expansion. The anchor may be deployed in structures subject to dry internal ​conditions and also in
structures subject to external atmospheric exposure in humid ​internal conditions or in other particular aggressive conditions e.g. immersion in seawater, ​chloride atmosphere or atmosphere with
chemical pollution (e.g. in desulphurization plants ​or road tunnels where de-icing materials are
used).
Technical Data
Ambient temperature
Type
Material
Color
Dimensions
-40 °C ... 110 °C
K6 x 30/15
polyamide (clamp),
zinc plated steel (anchor)
dark grey, similar to RAL 7001(clamp)
Ø: 6 mm L: 61 mm (metal anchor)
Please note: for mounting of the anchor, one ancher setting tool (Part No. 970144.IN) is necessary and is​
not included in delivery.
Other anchor lengths on request.
100 x plastic clamps
100 x anchor
1 x SDS drill
970142.IN
Stainless steel anchor with plastic clamp for Honeywell DTS cable
1
As 970140.IN but with stainless steel anchor.
Technical Data
Type
Material
Dimensions
K6 x 30/15
stainless steel (anchor)
Ø: 6 mm L: 61 mm (metal anchor)
100 x plastic clamps
100 x anchors
1 x SDS drill
970143.IN
Steel anchor with steel clamp for Honeywell DTS cables
1
As 970140.IN but with steel clamp, protected by rubber. The steel clamp complies with DIN ​3016.
Technical Data
Material
100 x steel clamps
100 x anchors
1 x SDS drill
162
www.hls-austria.com
steel zinc plated with rubber protection (clamp)
Detectors for Special Applications
970144.IN
Linear Heat Detectors
1
Anchor setting tool
To fix the metal anchor it is necessary to have one setting tool.
1 x setting tool
2
3
4
5
6
970146.IN
7
Micro splice-box IP20 for Honeywell DTS sensor cables
The splice box should only be used indoors and is suitable for cables with a diameter of max. 7.5
mm.
Technical Data
Type of protection
Material
Dimensions
8
lP20
thermoplastic PC-ABS, non-halogen, flame retardant
W: 100 mm H: 160 mm D: 30 mm
9
1 x splice cassette with splice holder
10
Features
• 2 cable inlets with sealing grommets
11
970147.IN
Splice-box IP67 for Honeywell DTS sensor cables
12
For indoor or ourdoor use.
Technical Data
Type of protection
Material
Dimensions
Features
13
lP67
Aluminum, coated gray
W: 82 mm H: 128 mm D: 57 mm
14
1 x splice cassette with splice holder
• 3 cable inlets with PG cable glands
970148
Double head cable ties, 500 pcs
163
Detectors for Special Applications
Linear Smoke Detectors
Fireray
761315
Fireray 50 RV with one prism
1
Approval: VdS
The detector consists of an integrated infrared transmitter and receiver. The signal is reflected by
a ​prism and analysed by the receiving element. Signal reaching the threshold will trigger an ​alarm.
Integration on the loop and the resetting function is carried out via the esserbus ​transponder
808623.
Integration on conventional line requires use of a reset module. The detector ​requires a separate
voltage supply of 24 V DC.
Features
• Compact housing
• Range 5 m to 50 m
• Robust construction
• Complies with EN 54-12 standard
• Monitoring and resetting is carried out via the ​
esserbus transponder 808623 during loop ​operation
The Fireray is installed approx. 0.3 to 0.8 m underneath the ceiling and its reflector with the ​same
ceiling distance opposite. There should be no reflecting obstacles in the transmission ​zone
(approx. 2 degrees).
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Alarm current @24 V DC
Contact load
Range
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Detector specification
CE certificate
Dimensions
10.2 ... 30 V DC
approx. 4 mA
approx. 15 mA
max. 30 V DC / 1 A
5 to 50 m
-20 °C ... 55 °C
-35 °C ... 60 °C
0% ... 93%, (non-condensing)
lP50
ABS plastic, flame resistant
gray, similar to RAL 7035
approx. 670 g
EN 54-12
0786-CPD-20045
W: 210 mm H: 117 mm D: 120 mm
1 prism 761322
esserbus
transponder
Monitored area
esserbus /
esserbus PLus
1 retro mirror
24 V DC
Operating range: 5 up to 50 m
Application example
761316
Fireray 100 RV with four prisms
1
As 761315, but with four prisms and max. operating range of 100 m.
4 prisms 761323
164
www.hls-austria.com
Detectors for Special Applications
761317
Linear Smoke Detectors
1
Fireray 5000, line smoke detector, incl. controller, 100 m
1
Approval: VdS, LPCB, UL
The Fireray 5000 combines an infrared transmitter and receiver in one detector head. The trans­
mission signal is reflected by a prism and analyzed on smoke concentration by the receiving unit.
The trans­mitting/receiving unit contains an electricactuator which always keeps the IR-ray in the
optimal orientation.
Electric actuator in detector head allows for remote manual alignment via remote controller and its
LCD display, keypad and laser indicator. The automatic, self-alignment mechanism keeps detector
head perfectly aligned with reflective prism regardless of vibrations or building construction
movement.
Features
• Remote system controller
• LASER assisted alignment
• Automatic contamination compensation
• Automatic IR beam path alignment
• Electric remote detector head orientation adjustment
1
761317.50
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Current consumption
Alarm current @ 24 V DC
Contact load
Range
Ambient temperature
Storage temperature
Type of protection
2
3
4
14 ... 28 V DC
approx. 10 mA
8 mA ... 12 mA (niedrigen Strom-Modus typ 10)
approx. 50 mA
100 mA / 30 V DC
8 ... 100 m
-20 °C ... 55 °C
-40 °C ... 85 °C
IP54
5
6
7
4 prisms 761322+761323
Fireray 5000, line smoke detector, incl. controller, 50 m
8
1
As 761317, but with a 50 m detection range.
Technical Data
Range
9
8... 50 m
1 prism 761322
10
11
12
13
14
165
Detectors for Special Applications
Linear Smoke Detectors
Reflectors and Accessories
The individual reflectors and reflector sets can also be used with the Fireray products.
However, please observe the additional planning information in the relevant functional ​
descriptions.
761401.10
Reflector set for LRMX, for ranges of up to 80 m
1
Metal reflector set for different types of linear smoke detectors. Suitable for ranges of up to 80 m.
Technical Data
Range
Dimensions
5 ... 80 m
W: 370 mm H: 370 mm D: 7 mm
Suitable for all lines of supplied beam detectors.
Steel plate; 4 x reflector 761403
761402.10
Reflector set for LRMX, for ranges of up to 100 m
1
Metal reflector set for range extension of LRMX up to 100 m.
Technical Data
Range
Dimensions
5 ... 100 m
W: 370 mm H: 370 mm D: 7 mm
Reflector sets also available on request with water-repellent reflectors Part No. 761413 (nano ​
coating) or additional built-in heating.
Suitable for all lines of supplied beam detectors.
Steel plate; 9 x reflector 761403
761403
Single reflector for LRMX
1
Replacement prism – single reflector for usage with the line smoke detector (Part No. 761400.10).
Technical Data
Range
Dimensions
5 ... 40 m
W: 100 mm H: 100 mm
Suitable for all lines of supplied beam detectors.
761317.H
Fireray 5000 detector head
Additional detector head for Fireray 5000 (761317).
166
www.hls-austria.com
Detectors for Special Applications
761317.50.H
Linear Smoke Detectors
1
Fireray 5000 detector head
1
Additional detector head for Fireray 5000 (761317.50).
2
3
761312
Ceiling pendant mount for Fireray
4
1
Ceiling pendant mount for F2000, F5000, F50RV, F100RV and universal bracket 761314
Technical Data
Weight
5
approx. 3.4 kg
6
7
761314
Univ. bracket for F5000 or prism plate 761440/761441
1
Universal bracket for a F5000 detector head or prism plate 761440 or 761441
Technical Data
Weight
8
approx. 300 g
9
10
761440
Plate for 1 prism
1
11
Prism plate for 1 prism for use with bracket 761314
Technical Data
Weight
approx. 150 g
12
Prism and bracket are not included!
13
761441
Plate for 4 prism
14
1
Prism plate for 4 prisms for use with bracket 761314
Technical Data
Weight
approx. 300 g
Prisms and bracket are not included!
167
Detectors for Special Applications
Linear Smoke Detectors
761404.10
Ceiling holder for LRMX, for distances from 40 to 70 cm
1
For better mounting of the line smoke detector (Part No. 761400.10) on walls, girders, ceilings and ​
beams. The ceiling bracket is made of aluminum and can be adjusted in length anywhere from 40 ​
to 70 cm. A high-grade ball joint mounting bracket is located on the top side for easy wall/ceiling ​
mounting. The ceiling bracket is suitable for attaching the mounting plate Part No. 761406.
Technical Data
Weight
approx. 2.3 kg
Ceiling bracket incl. mounting material for the aluminum holder but does not include material for ​mounting of the holder on ceilings, walls or beams.
Features
• For easy ceiling and wall mounting in compli­
ance with DIN VDE 0833-2
• Optimal alignment of detector and reflectors ​
under difficult ambient conditions via ball joint ​
mounting bracket
• Extendable ceiling bracket for flexible adjust­
ment of length for distances of 400 to 700 mm
• Invisible cable routing inside the ceiling
• Capacity 25 kg
• Swivel hinge approx. 180°
• Ball joint approx. 90° and holding fixture for ​
prism reflector
• RAL 9010 (pure white) surface
761405.10
Ceiling holder for LRMX, for distances from 70 to 150 cm
1
Same as 761404.10 but extendable for ceiling clearances from 70 to 150 cm.
Technical Data
Weight
168
approx. 3.3 kg
761406
Mounting plate for ceiling bracket for detector/single reflector
1
Mounting plate made of aluminum for attaching the line smoke detector Part No. 761400.10 or the ​
prism reflector Part No. 761403 on the ceiling bracket.
761407
Mounting spider for ceiling bracket
1
Mounting spider for the ceiling brackets (Part No. 761404.10 and 761405.10) for alternative attach­
ment of the reflector sets (Part No. 761401.10 and 761402.10) on the ceiling bracket.
www.hls-austria.com
Detectors for Special Applications
Linear Smoke Detectors
1
Open-area Smoke Imaging Detection (OSID)
1
The linear smoke detector OSID using dual wavelength detects only repeatable absolute smoke ​
obscuration values, while rejecting the presence of dust particles or solid intruding objects. This is ​
already provided using the simplest configuration – one imager and one emitter. One imager can ​
work with up to seven emitters.
An optical imaging array in the OSID detector provides a wider viewing angle to locate and capture ​
images. Consequently, the system is easier to install and align and can compensate for drift ​
caused by natural shifts in building structures.
2
3
In addition, OSID requires only limited space (15 - 20 cm) in ist line of view. Therefore, the solution ​
can be deployed safely between ceilings and supporting structures, moving cranes, etc.
Features
• Patented dual wavelength, UV & IR, particle ​
detection
• High immunity to dust, fogging, steam, reflec­
tions and object intrusion
• High tolerance to vibration and structural move­
ment
• Easy alignment with large adjustment and ​
viewing angles
• Simple installation, commissioning and mainten­
ance
• Simple DIP switch configuration
• 3D volumetric coverage
• Maximum detection range up to 150 meters
• 3 levels of sensitivity possible (35%, 45%, 60​%)
4
Each component can be mounted directly to the surface or can be secured with the supplied ​
mounting brackets.
Field of View
Max
Max.
Number
of
Emitters
10°
7°
4°
30 m (98 ft) 150 m (492 ft)
--
--
1
45°
38°
19°
15 m (49 ft) 60 m (197 ft)
30 m (98 ft)
120 m (393 ft)
7
90°
80°
48°
6 m (20 ft)
**34 m (111 ft) 12 m (39 ft)
**68 m (223 ft)
7
Imager
Detection Range
Standard Power
Horizontal
High Power
Vertical
Min
Max
Min
5
6
7
** Maximum Distances measured for the Center Field of View of the Imager. For more details on distances for the
Imager, see the OSID Product Guide.
Technical Data
Operating voltage
Range
Alignment angle
Ambient temperature
Air humidity
Type of protection
Weight
Detector specification
Dimensions
8
20 ... 30 V DC
< 150 m
-60° ... 60° (h), -15 ... 15° (v)
-10 °C ... 55 °C
10 ... 95 % (non-condensing)
IP44 (electronic)
IP66 (optical housing)
approx. 651 g
EN 54-12
W: 198 mm H: 130 mm D: 96 mm
9
10
11
12
13
14
169
Detectors for Special Applications
761300
Linear Smoke Detectors
OSID Imager - 7° coverage
Approval: G211072
1
Features
• Field of view coverage: horizontal 7°, vertical 4°
Imager for use with OSID emitter (Part No.: 761303 – 761305).
Image sensor / receiver for smoke detection for open spaces, evaluation. Two light sources (IR ​and
UV), optical filters, high-speed image capture and intelligent software algorithms to increase ​the
noise immunity and safety from erroneous / false alarms, 1 light source can be connected, via ​
sensors and DIP switch individually configurable.
Technical Data
Current consumption @ 24 V DC
Weight
approx. 4 mA @ 1 imager, 7 mA @ 7 imagers
approx. 651 g
Accessories
761310 OSID Installation Kit
761303 Emitter - Standard Power, battery version
761304 Emitter - Standard Power, wired at 24 V DC
761305 Emitter - High Power, wired at 24 V DC
761302
OSID Imager - 80° coverage
1
As 761300, but with field of view coverage: horizontal 80°, vertical 48°.
761303
OSID Emitter standard power, battery version
1
Features
The emitter produces two light sources (UV / IR) which are evaluated by an OSID imager. The
built-in battery lasts 5 years.
• Built-in 5 year battery
Technical Data
Weight
Dimensions
approx. 563 g
W: 130 mm H: 198 mm D: 96 mm
Accessories
761310 OSID Installation Kit
761300 Imager - 7° Coverage, 24 V DC
761302 Imager - 80° Coverage, 24 V DC
761304
OSID Emitter standard power
1
As 761303, but wired.
Technical Data
Current consumption @ 24 V DC
761305
approx. 0,35 mA
OSID Emitter, high power
1
As 761304, but with high powered emitter.
Technical Data
Current consumption @ 24 V DC
170
www.hls-austria.com
approx. 0,8 mA
Detectors for Special Applications
761310
Linear Smoke Detectors
1
OSID installation kit
1
The installation kit is used for commisioning and maintenance of the OSID smoke detector.
2
1 x Laser alignment tool
1 x Test filter
1 x PC cable
1 x Cleaning cloth
1 x Manual
761330
3
IP66 housing for OSID standard light source (emitter)
4
Technical Data
Ambient temperature
Type of protection
Material
Dimensions
5
1
-25 °C ... 60 °C
IP66 , IK 07
ABS
W: 241 mm H: 194 mm D: 127 mm
6
7
761331
IP66 housing for OSID image sensor (imager)
8
1
Technical Data
Ambient temperature
Type of protection
Material
Dimensions
-25 °C ... 60 °C
IP66 , IK 07
ABS
W: 241 mm H: 194 mm D: 127 mm
9
10
11
12
13
14
171
Detectors for Special Applications
Aspirating Smoke Detectors
Aspirating Smoke Detector - FAAST
8100E
ASD FAAST XM
Approval: G 212002
1
The FAAST (Fire Alarm Aspiration Sensing Technology®) system is a aspirating smoke detector ​
that draw air into a patented, high-sensitivity smoke-sensing chamber through a pipe network, it ​
delivers highly accurate and discrete early warning fire detection. FAAST’s dual vision sensing ​
technology uses a blue LED to detect a wide variety of fires with extremely low concentrations of ​
smoke and an infrared laser to identify nuisances (like dust) which can cause false alarms. ​
Advanced algorithms interpret signals from both sources to meet one single focus. It includes 5 ​
alarm levels, 10 pre-alarm particulate levels and a 10-level airflow pendulum which verifies that air ​
is flowing effectively through the pipe network. The patented particle separator and field-replace­
able filter remove contaminants from the pipe-system.
Features
• Wide detection range between 0.00095 % and ​
20.5 % obs/m
• Five alarm levels (Alert, Action 1 & 2, Fire 1 ​& 2)
• Maximum Single Pipe Length 120 m
• Maximum Branched Pipe Length 320 m
• Maximum Air Inlet Holes 36 holes
• Automatically adjusts to current environmental ​
conditions to reduce nuisance alarms, Acclimate ​
mode
• Detector combines dual source chamber with a ​
reliable and quick-responding blue LED techno­
logy and infra-red laser
• Advanced detection algorithms reject common ​
nuisance conditions
• Ultrasonic and electronic sensing for pipe and ​
chamber air flow measurement
• Patented particle separator and field-replace­
able filter
• Integral Ethernet interface enables remote ​monitoring and e-mail status updates (up to 6 E-​Mail
addresses)
• Particulate graph displays subtle environmental ​
changes
• Fault indictors provide a broad spectrum of ​
events
• Unique air flow pendulum graph verifies pipe ​
network functionality
• Event Log stores 18.000 events
• PipelQ SW for programming pipe layout, system ​
configuration and ongoing system monitoring
• 8 potential free relays output for connection at ​
FACP
• Loop connection via esserbus-alarm ​transponder Part. No. 808623
172
www.hls-austria.com
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Area to be monitored
Ambient temperature
Sampled Air Temperature
Air humidity
Type of protection
Housing
Color
Weight
Specification
Dimensions
Declaration of Performance
18 ... 30 V DC
approx. 415 mA
approx. 465 mA
max. 2000 m²
-10 °C ... 55 °C
-20 °C ... 60 °C
10 ... 95 % (non-condensing)
IP 30
Plastic (ABS)
black
approx. 3.74 kg
EN 54-20
W: 330 mm H: 337 mm D: 127 mm
DOP 0786-CPD-21130
Please order separately the corresponding language package, see category accessory!
Accessories
F-A-LC-E
Language package Estonian, Latvian, Lithuanian, Russian
F-A-LC-G
Language package Polish, Czech, Slovak, Hungarian
F-A-LC-H
Language package Slovenian, Croatian, Romanian, Hungarian
F-A3384-000 FAAST Replacement Air Filter
Detectors for Special Applications
F-A-LC-A
Aspirating Smoke Detectors
1
Language package German, French, Italian, Dutch
The language package for Aspirating FAAST XM includes the front foils in the languages ​German,
French, Italian and Dutch.
2
4 x front foils
F-A-LC-E
3
Language package Estonian, Latvian, Lithuanian, Russian
The language package for Aspirating FAAST XM includes the front foils in the languages ​Estonian,
Latvian, Lithuanian and Russian.
4
4 x front foils
F-A-LC-G
5
Language package Polish, Czech, Slovakian, Hungarian
The language package for Aspirating FAAST XM includes the front foils in the languages ​Polish,
Czech, Slovakian and Hungarian.
6
4 x front foils
7
F-A-LC-H
Language package Slovenian, Croatian, Romanian, Hungarian
The language package for Aspirating FAAST XM includes the front foils in the languages ​Slovenian, Croatian, Romanian, Hungarian.
8
4 x front foils
9
F-A3384-000
Replacement air filter for FAAST XM
Replacement air filter for aspirating smoke detector FAAST XM.
10
1
1 x Air filter
11
12
13
14
173
Detectors for Special Applications
801711
Aspirating Smoke Detectors
ASD FAAST LT EB, single channel
Approval: pending
1
Features
• 2 independant detection chambers w. individual
laser smoke detector, fan, filter, sensor and
monitor
• 1 channel system for connection of max. 2 pips
per channel
• Bild-in and preconfigured esserbus transponder
• High sensitivity laser optics
• 9 sensitivity levels from 0.07 % to 6.5 % obs/m
• Fault indictors provide a broad spectrum of ​
events
• PipelQ SW for programming pipe layout, system ​
configuration and ongoing system monitoring
• Simple LED overview with detailed fault status
display
• Unique air flow pendulum graph verifies pipe ​
network functionality
• 10 adjastable fan levels
• Advanced detection algorithms reject common ​
nuisance conditions
• Automatically adjusts to current environmental ​
conditions to reduce nuisance alarms, Acclimate ​
mode
• Event Log stores up to 2.244 events
• Ultrasonic and electronic sensing for pipe and ​
chamber air flow measurement
• USB interface
• Easily replaceable and reusable filter
The FAAST (Fire Alarm Aspiration Sensing Technology®) system is a aspirating smoke detector ​
that draw air into a patented, high-sensitivity smoke-sensing chamber through a pipe network, it ​
delivers highly accurate and discrete early warning fire detection. FAAST LT EB includes high
sensitivity laser fire detection, ultrasonic flow sensors, and internal design features to protect
vulnerable components from environmental and human threats. The device is fast to install and
easy to commission thanks to PipeIQ LT pipe design and configuration software which is included
as standard.
The FAAST LT esserbus will be connected direct on the esserbus. All devices are member from
the esserbus loop and will be easy programmed with Commissioning Software tools8000.
A range of customisable settings are geared towards maximising device performance and
meeting different application needs. To accommodate local installation standards or environments,
flow and general fault delays can also be set.
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Operation sound level @ 24 V DC
Area to be monitored
Max. single pipe length
Max. total branched pipe length
Max. air inlet holes
Ambient temperature
Aspirated air temperature
Air humidity
Type of protection
Housing
Color
Weight
Specification
Dimensions
Declaration of Performance
18.5 ... 31.5 V DC
approx. 182 mA
approx. 480 mA
26 dB (A) (fan level 1)
max. 1600 m²
100 m
160 m
18
-10 °C ... 55 °C
-20 °C ... 60 °C
10 ... 95 % (non-condensing)
IP65
Plastic (ABS)
black/gray
approx. 4 kg
EN 54-20, Class A,B, C
W: 356 mm H: 403 mm D: 135 mm
DOP-ASP004
24 language foils are included
Accessories
FL-IF-6 FAAST LT replacement integral filter
801722
ASD FAAST LT EB, dual channel
Features
Technical Data
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Operation sound level @ 24 V DC
Declaration of Performance
As 801722, but with 2 independant channels and one laser smoke detector per channel.
• 2 independant detection chambers w. individual
laser smoke detector, fan, filter, sensor and
monitor
approx. 282 mA
approx. 690 mA
28 dB (A) (fan level 1)
DOP-ASP005
• 2 channel system for connection of max. 2 pips
per channel
FL-IF-6
Replacement integral filter for FAAST LT EB
Replacement integral filter for aspirating smoke detector FAAST LT EB.
6 x Integral filter
174
www.hls-austria.com
Detectors for Special Applications
801544.10
Aspirating Smoke Detectors
1
Air filter for aspirating smoke detectors
1
Air filter for usage in areas with interfering environmental influences e.g. dust.
Technical Data
Application temperature
Material
Color
Dimensions
2
-30 °C ... 60 °C
ABS plastic
gray, similar to RAL 7035
W: 122 mm H: 194 mm D: 96 mm
3
Suitable for FAAST products
4
Filter cartridges (1 x 60 ppi, 1 x 45 ppi, 1 x 25 ppi)
5
801604
Replacement air filter pads for 801544.10
1
Replacement cartridge for air filters (801544.10), consisting of one fine, medium and coarse ​filter
pad each.
6
Suitable for FAAST products
7
Filter cartridges (1 x 60 ppi, 1 x 45 ppi, 1 x 25 ppi)
1 Set
8
9
10
11
12
13
14
175
Detectors for Special Applications
VLP-400
Aspirating Smoke Detectors
VESDA VLP
Approval: G 298024
1
The VESDA VLP detector has an alarm sensitivity range of 0.005%–20% obscuration/m
(0.0015%–6.25% obscuration/ft). The VLP is classed as a “Very Early Warning Smoke Detector”,
which means that it detects fire at the earliest possible stage and reliably measures very low to
extremely high concentrations of smoke.
The detection chamber uses a stable Class 1 laser light source and carefully positioned sensors to
achieve the optimum response to a vast range of smoke types. The status of the detector, and all
alarm, service and fault events, are transmitted to displays and external systems via VESDAnet.
Features
• Wide sensitivity range
• Laser based smoke detection
• 4 configurable alarm levels
• High efficiency aspirator
• Four inlet pipes
• Airflow supervisor per sampling pipe
• Clean air barrier optics protection
• Easy to replace air filter
• 7 programmable relays
• AutoLearn™
• Event log – up to 18000 events
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Area to be monitored
Contact load relay
Alarm sensitivity
Cable termination
Max. single pipe length
Max. total branched pipe length
Ambient temperature
Aspirated air temperature
Air humidity
Type of protection
Weight
Specification
Dimensions
18 ... 30 V DC
max. 340 mA
max. 390 mA
max. 2000 m²
2 A @ 30 V DC NO/NC contacts
0.005%–20% obs/m (0.0015%–6.25% obs/ft)
0.2–2.5 sq mm
100 m
200 m
0 °C ... 38 °C
-20 °C ... 60 °C
10 ... 95 % (non-condensing)
IP30
approx. 4 kg
EN 54-20, Class A, B, C
W: 350 mm H: 225 mm D: 125 mm
Filter included in detector
Accessories
VSP-005 VESDA Filter for VLP, VLS, VLF, VLC
VLS-600
VESDA VLS
As VLP-400 (VESDA VLP) , but also includes a valve mechanism in the inlet manifold and software
to control the airflow from the four sectors (pipes). This configuration enables a single VESDA zone
to be divided into four separate sectors, for example, distinguishing between separate voids within
a room.
1
Technical Data
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Alarm sensitivity
Features
• 4 configurable alarm levels
• Four inlet pipes
• 7 or 12 programmable relay options
176
www.hls-austria.com
max. 280 mA
max. 300 mA
0.005%–20% obs/m (0.0015%–6% obs/ft)
Detectors for Special Applications
VLC-500RO
Aspirating Smoke Detectors
1
VESDA VLC
Approval: G 298024
1
Features
• Absolute smoke detection
• Wide sensitivity range
• Single pipe inlet
• Five status LEDs
• Clean air barrier optics protection
• Three alarm levels
• Three programmable relays
• Air flow monitoring
• Simple mounting design
• AutoLearn™
• Event log – up to 12000 events
The VESDA VLC detector has been specifically designed to provide all the benefits of aspirating
smoke detection, including very early warning, in single environment small areas and where space
is a premium.
The VLC combines the well-proven VESDA VLP detection technology with a modified aspirator
design, and incorporates them into a compact enclosure with a simplified display.
The detector interfaces via relays only.
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Area to be monitored
Contact load relay
Alarm sensitivity
Cable termination
Max. single pipe length
Ambient temperature
Aspirated air temperature
Air humidity
Type of protection
Weight
Specification
Dimensions
2
3
4
18 ... 30 V DC
approx. 225 mA
approx. 245 mA
max. 800 m²
2 A @ 30 V DC NO/NC contacts
0.005%–20% obs/m (0.0015%–6.25% obs/ft)
0.2–2.5 sq mm
80 m
0 °C ... 38 °C
-20 °C ... 60 °C
10 ... 95 % (non-condensing)
IP30
approx. 1,9 kg
EN 54-20, Class A, B, C
W: 225 mm H: 225 mm D: 85 mm
5
6
7
8
Filter included in detector
Accessories
VSP-005 VESDA Filter for VLP, VLS, VLF, VLC
VLF-250
9
VESDA VLF-250
Approval: G 205060
1
Features
• Out-of-the-Box installation and commissioning
• Ultrasonic airflow sensing
• Laser-based absolute smoke detection
• Programmable alarm thresholds
• Clean air barrier optics protecti
• AutoLearn™ Flow
• AutoLearn™ Smoke
• Event log – up to 18000 events
10
The VESDA VLF-250 detector is a very early warning smoke detector designed to protect small,
business-critical environments of up to 250 m2.
The VLF can be installed and commissioned out-of-the-box without the need for a special interface
or software programming tools. The patent-pending Ultrasonic Flow Sensing used in the VLF
provides a direct reading of the sampling pipe fl ow rate. The system is immune to air temperature
and pressure changes and is unaffected by contamination. The VLF is the first air sampling smoke
detector to use ultrasonic flow sensing.
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Area to be monitored
Contact load relay
Cable termination
Max. single pipe length
Ambient temperature
Aspirated air temperature
Air humidity
Type of protection
Weight
Specification
Dimensions
11
12
18 ... 30 V DC
approx. 220 mA
approx. 295 mA
max. 250 m²
2 A @ 30 V DC NO/NC contacts
0.2–2.5 sq mm
25 m
0 °C ... 38 °C
-20 °C ... 60 °C
5 ... 95 % (non-condensing)
IP30
approx. 2 kg
EN 54-20, Class A, B, C
W: 256 mm H: 183 mm D: 92 mm
13
14
Filter included in detector
Accessories
VSP-005 VESDA Filter for VLP, VLS, VLF, VLC
VLF-500
VESDA VLF-500
As VLF-250 but for areas up to 500 m2.
Technical Data
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
approx. 410 mA
approx. 490 mA
177
Detectors for Special Applications
VLI-880
Aspirating Smoke Detectors
VESDA VLI Relay only
Approval: G 212155
1
The VESDA VLI is an early warning aspirating smoke detection (ASD) system, designed to protect
industrial applications and harsh environments of up to 2000 m2.
The VLI detector combines a fail-safe intelligent filter (patent pending) with an advanced clean-air
barrier for optics protection allowing the use of absolute detection and a long detection chamber
life without the need for re-calibration.
Features
• Suitable for Class 1 Division 2 applications
- Groups A,B,C & D
• Up to 4 inlet pipes
• Five high intensity status LEDs for greater visibility
• Robust absolute smoke detection
• Intelligent Filter (patent pending)
• Lint Trap to capture fibrous particulates
• Secondary filter
• Clean air barrier for optics protection
• AutoLearn™ Smoke and Flow
• Clean Air Zero™
• Air-path monitoring
• Five relays (Fire, Fault and 3 configurable)
• Ultrasonic flow sensing
The intelligent filter:
• reduces the level of pollution in the air sample before it enters the detection chamber, which
dramatically extends the operational life of the detector in harsh and polluted environments.
• is fully monitored, providing consistent sensitivity over the entire operational life of the detector.
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Area to be monitored
Contact load relay
Cable termination
Alarm sensitivity
Max. single pipe length
Max. total branched pipe length
Ambient temperature
Aspirated air temperature
Air humidity
Type of protection
Weight
Specification
Dimensions
18 ... 30 V DC
approx. 415 mA
approx. 440 mA
max. 2000 m²
2 A @ 30 V DC NO/NC contacts
0.2–2.5 sq mm
0.005%–20% obs/m (0.0015%–6.25% obs/ft)
120 m
360 m
0 °C ... 38 °C
-20 °C ... 60 °C
10 ... 95 % (non-condensing)
IP66
approx. 6 kg
EN 54-20, Class A, B, C
W: 426.5 mm H: 316.5 mm D: 180 mm
Filter included in detector
VLI-885
VESDA VLI with VesdaNet
As VLI-880 but with VesdaNet implemented.
178
www.hls-austria.com
Detectors for Special Applications
VEU-A00
Aspirating Smoke Detectors
1
VESDA VEU with LEDs
Approval: G 214010
1
The VEU series of aspirating smoke detectors are the premium detector of the VESDA-E range.
An Ultra-wide sensitivity range; 15 times greater than VESDA VLP, and provision for more
sampling holes provide an increased coverage in high airflow applications by at least 40%. Considerably longer linear pipe runs and extended branched pipe network configurations cater perfectly
to applications with higher ceilings providing an increased coverage by up to 80% whilst allowing
convenient detector mounting for ease of service and maintenance. A range of revolutionary new
features provide unsurpassed detection performance, flexibility, field programmability, connectivity
and reduced total cost of ownership.
2
3
4
Features
• Multi stage filtration and optical protection with
clean air barriers
• Four alarm levels and an ultra wide sensitivity
range
• Secondary monitoring and maintenance via WiFi
• USB for PC configuration, and firmware upgrade
using a memory stick
• Remote monitoring with iVESDA
• Fully backward compatible with VLP and
VESDAnet
• AutoLearn™ smoke and flow
• Extensive event log - 20 000 events
Flair Detection Technology
Flair is the revolutionary new detection chamber that forms the core of VESDA-E VEU, providing
better detection, fewer nuisance alarms, higher stability, increased longevity and particle characterisation. Direct imaging of the sampled particles using a CMOS imager combined with multiple
photo-diodes provides vastly more data that can be used to derive actionable information about the
observed particles using analytics.
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Area to be monitored
Contact load relay
Cable termination
Alarm sensitivity
Max. single pipe length
Max. total branched pipe length
Number of holes (A/B/C)
Ambient temperature
Aspirated air temperature
Air humidity
Type of protection
Weight
Specification
Dimensions
5
6
18 ... 30 V DC
max. 613 mA
max. 646 mA
max. 6 500 m²
2 A @ 30 V DC NO/NC contacts
0.2–2.5 sq mm
0.001%–20% obs/m (0.0003%–6.25% obs/ft)
160 m
800 m
80/80/100
0 °C ... 38 °C
-20 °C ... 60 °C
10 ... 95 % (non-condensing)
IP40
approx. 4,83 kg
EN 54-20, Class A, B, C
W: 350 mm H: 225 mm D: 135 mm
7
8
9
10
Filter included in detector
11
Accessories
VSP-962 VESDA Filter for VEU, VEP
12
VEU-A10
VESDA VEU with Display
As VEU-A00 but with a 3,5" display.
13
1
Technical Data
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Weight
approx. 658 mA
approx. 692 mA
approx. 4,9 kg
14
179
Detectors for Special Applications
VEP-A00-P
Aspirating Smoke Detectors
VESDA VEP 4 pipe with LEDs
Approval: G 214010
1
The VESDA-E VEP series of smoke detectors bring the latest and most advanced detection technology to provide very early warning and the best nuisance alarm rejection to a wide range of
applications. Built on the Flair detection technology and years of application experience, VEP
detectors achieve consistent performance over their lifetime via absolute calibration. In addition,
the VEP delivers a range of revolutionary features that provide user value.
Features
• Multi stage filtration and optical protection with
clean air barriers
• Four alarm levels and an ultra wide sensitivity
range
• Secondary monitoring and maintenance via WiFi
• USB for PC configuration, and firmware upgrade
using a memory stick
• Remote monitoring with iVESDA
• Fully backward compatible with VLP and
VESDAnet
• AutoLearn™ smoke and flow
• Extensive event log - 20 000 events
Flair Detection Technology
Flair is the revolutionary new detection chamber that forms the core of VESDA-E VEP, providing
better detection, fewer nuisance alarms, higher stability, increased longevity and particle characterisation. Direct imaging of the sampled particles using a CMOS imager combined with multiple
photo-diodes allow vastly more data that can be used to derive actionable information about the
observed particles using analytics.
Technical Data
Operating voltage
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Area to be monitored
Contact load relay
Cable termination
Alarm sensitivity
Max. single pipe length
Max. total branched pipe length
Number of holes (A/B/C)
Ambient temperature
Aspirated air temperature
Air humidity
Type of protection
Weight
Specification
Dimensions
18 ... 30 V DC
max. 367 mA
max. 400 mA
max. 2 000 m²
2 A @ 30 V DC NO/NC contacts
0.2–2.5 sq mm
0.005%–20% obs/m (0.00016%–6.25% obs/ft)
110 m
560 m
40/80/100
0 °C ... 38 °C
-20 °C ... 60 °C
10 ... 95 % (non-condensing)
IP40
approx. 4 kg
EN 54-20, Class A, B, C
W: 350 mm H: 225 mm D: 135 mm
Filter included in detector
Accessories
VSP-962 VESDA Filter for VEU, VEP
VEP-A10-P
VESDA VEP 4 pipe with display
As VEP-A00 but with a 3,5" display.
Technical Data
Quiescent current @ 24 V DC
Alarm current @ 24 V DC
Weight
VEP-A00-1P
max. 417 mA
max. 483 mA
approx. 4,1 kg
VESDA VEP 1 pipe with LEDs
As VEP-A00 but with one pipe.
Technical Data
Max. single pipe length
Max. total branched pipe length
Number of holes (A/B/C)
180
www.hls-austria.com
100 m
130 m
30/40/45
Detectors for Special Applications
Aspirating Smoke Detectors
761517
VESDAnet™ connection box
1
1
This connection box enables external devices to be connected to the VESDANet™. For example, ​
a handheld programmer or a PC can be connected in conjunction with the PC interface to program ​
the system.
2
3
4
761506
VESDA 300 PC interface
1
Used as an alternative to the programming unit. All components on the VESDAnet™ can be ​
programmed via the interface.
5
Technical Data
Current consumption
Dimensions
6
70 mA
W: 190 mm H: 100 mm D: 40 mm
The two required connectors are included.
7
VSP-962
VESDA filter for VEU, VEP
8
Replacement air filter for VESDA VEU and VEP detectors.
1 piece
9
10
VSP-005
VESDA filter for VLP, VLS, VLF, VLC
Replacement air filter for VESDA VLP, VLS, VLF and VLC detectors.
11
1 piece
12
761509
Air filter for VESDA aspirating systems
13
1
External filter for VESDA aspirating system for extremely polluted environments.
Technical Data
Color
Dimensions
14
gray, similar to RAL 7035
W: 206 mm H: 59 mm D: 33 mm
761514
Replacement filter for 761509
1
Replacement filter cartridge for air filter Item No. 761509. 1 set consisting of 4 filter cartridges.
181
Detectors for Special Applications
Aspirating Smoke Detectors
Accessories
950101
1
Pipe (PVC), diameter 25 mm
Length = 25 m (each 5 m)
Technical Data
Ambient temperature
-10 °C ... 60 °C
5 pcs
761520.10
Pipe (ABS), diameter 25 mm
1
Length = 30 m (each 3 m)
Technical Data
Ambient temperature
-40 °C ... 70 °C
10 pcs
950119
90° bend (PVC) for 25 mm pipe
1
Technical Data
Ambient temperature
-10 °C ... 60 °C
10 pcs
761521.10
1
90° bend (ABS) for 25 mm pipe
As 950119 but ABS material.
Technical Data
Ambient temperature
950104
-40 °C ... 70 °C
90° angle (PVC) for 25 mm pipe
1
Technical Data
Ambient temperature
-10 °C ... 60 °C
10 pcs
761522.10
90° angle (ABS) for 25 mm pipe
1
As 950104 but ABS material.
Technical Data
Ambient temperature
182
www.hls-austria.com
-40 °C ... 70 °C
Detectors for Special Applications
950107
Aspirating Smoke Detectors
1
45° angle (PVC) for 25 mm pipe
1
Technical Data
Ambient temperature
-10 °C ... 60 °C
2
10 Pcs.
3
4
761523.10
45° angle (ABS) for 25 mm pipe
5
1
As 950107 but ABS material.
Technical Data
Ambient temperature
950110
-40 °C ... 70 °C
6
7
T-Piece (PVC) for 25 mm pipe
1
Technical Data
Ambient temperature
-10 °C ... 60 °C
8
10 pcs
9
10
761524.10
T-Piece (ABS) for 25 mm pipe
11
1
As 950110 but ABS material.
Technical Data
Ambient temperature
950116
-40 °C ... 70 °C
12
13
Sleeve (PVC) for 25 mm pipe
1
Technical Data
Ambient temperature
-10 °C ... 60 °C
14
10 Pcs.
761525.10
Sleeve (ABS) for 25 mm pipe
1
As 950116 but ABS material.
Technical Data
Ambient temperature
-40 °C ... 70 °C
183
Detectors for Special Applications
950113
Aspirating Smoke Detectors
End cap (PVC) for 25 mm pipe
1
Technical Data
Ambient temperature
-10 °C ... 60 °C
10 pcs
761526.10
End cap (ABS) for 25 mm pipe
1
As 950113 but ABS material.
Technical Data
Ambient temperature
-40 °C ... 70 °C
761549
Ceiling lead-through adapter (ABS)
1
Ceiling lead-through adapter (ABS) for suction hose set (Part No. 761542.10).
Almost invisible integration into false ceilings
761542.10
Suctions hose set for 25 mm pipe
1
For flexible installation in object surveillance or suspended ceilings.
All components are pre-mounted, but not glued; to enable cut and adaptation on-site.
Technical Data
Dimensions
L: 3000 mm
1 x T piece (761524), 3 m corrugated polyester hose, (761543), 1 x ceiling lead-through adapter with ​
threaded joint
T-piece
False
ceiling
Suspended ceiling
Application example: monitoring of room
184
www.hls-austria.com
Pipe
Polyester hose
Aspirator sampling
assembly
Detectors for Special Applications
Aspirating Smoke Detectors
1
801602
3-way ball valve (PVC)
1
For manual disconnection of aspirating smoke detectors from connected piping system during the ​
blow cleaning process with compressed air.
2
Technical Data
Ambient temperature
Material
Dimensions
3
0 °C ... 50 °C
ABS
L: 131 mm
includes three transition screw joints for connection to a 25 mm piping system
4
5
801607
1
3-way ball valve (ABS)
As 801602 but ABS material.
6
7
801606
Condensate trap for aspirating smoke detectors
1
Condensate trap with sintered metal filter for separation and absorption of condensed liquids, used ​
for protecting aspirating smoke detectors including threaded cable connection and mounting ​
bracket.
Features
• Plastic housing with manual outlet valve
• Plug connectors for attaching to a piping system
Technical Data
Ambient temperature
Material
Color
Weight
Dimensions
8
0 °C ... 80 °C
ABS
light gray
approx. 620 g
W: 68 mm H: 680 mm D: 36 mm
9
10
Air filter
11
12
Inlet
Outlet
Aspirating
smoke
detector
13
Condensate separator
14
Outlet
Application example
185
Detectors for Special Applications
Aspirating Smoke Detectors
761535
Adhesive, 0.5 kg can with brush-in-cap
1
Adhesive for connecting ABS and PVC pipes.
761536
PVC detergent, 1l
1
Detergent for cleaning ABS and PVC pipes and fittings before gluing.
761537.10
Mounting clip for 25 mm pipe
1
100 pcs
761546.10
Pipe cutter for PVC and ABS pipes
1
Technical Data
Material
ABS
Tool for clean, fast pipe cuts. For thin-walled pipes also, Ø ≤ 63 mm Ø ≤ 2".
186
www.hls-austria.com
Detectors for Special Applications
Aspirating Smoke Detectors
1
Reducing Film Sheets
1
Only 10 mm drill necessary
No annoying whistling
Defined diameter, easilyreadable on site
Finely graduated for optimal flow balance
2
10 pcs
3
4
801551
Aspiration reducing film sheet, 2.0 mm
801552
Aspiration reducing film sheet, 2.5 mm
801553
Aspiration reducing film sheet, 3.0 mm
7
801554
Aspiration reducing film sheet, 3.2 mm
8
801555
Aspiration reducing film sheet, 3.4 mm
9
801556
Aspiration reducing film sheet, 3.6 mm
10
801557
Aspiration reducing film sheet, 3.8 mm
801558
Aspiration reducing film sheet, 4.0 mm
801559
Aspiration reducing film sheet, 4.2 mm
5
6
11
12
13
14
801560
Aspiration reducing film sheet, 4.4 mm
801561
Aspiration reducing film sheet, 4.6 mm
801562
Aspiration reducing film sheet, 5.0 mm
801563
Aspiration reducing film sheet, 5.2 mm
801564
Aspiration reducing film sheet, 5.6 mm
187
Detectors for Special Applications
188
Aspirating Smoke Detectors
801565
Aspiration reducing film sheet, 6.0 mm
801566
Aspiration reducing film sheet, 6.8 mm
801567
Aspiration reducing film sheet, 7.0 mm
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
11
Alarm Devices
Conventional ENscape
Intelligent Addressable IQ8Alarm
190-196 12
197-206
Intrinsically Safe
207
Remote Indicators
208
13
14
189
Alarm Devices
CWSO-RR-S1
Conventional ENscape
Acoustic alarm signaling device, red
Approval: G 215015
1
The acoustic alarm signaling device is EN 54-3 compliant, in red housing, and offers a selection of ​
32 signal tones including the DIN tone and other country-specific tones. All tones comply with EN ​
54-3. Configuration takes place via a 6-pin DIP switch. Up to two different signal tones may be ​activated. Signaling device with flat base, suitable for wall and ceiling mounting.
77
mm
102
mm
100 mm
Features
• EN 54-3 compliant
• Suitable for 12 V and 24 V DC service voltage
• Synchronous sound trigger
• Volume adjustable to 2 levels at the device
CWSO-WW-S1
Technical Data
Operating voltage
Current consumption @ 12 V DC
Current consumption @ 24 V DC
Sound level @ 12 V DC
Sound level @ 24 V DC
Connection terminal
Ambient temperature
Air humidity
Type of protection
Material
Color
Weight
Specification
Dimensions
9 ... 29 V DC
approx. 14.9 mA (@ DIN tone)
approx. 33.4 mA (@ DIN tone)
96.2 dB(A) (@ DIN tone)
102.1 dB(A) (@ DIN tone)
0.5 ... 2.5 mm2
-25 °C ... 70 °C
< 96 % (non-condensing)
IP21C, IP65 with CWR and accessories
PC/ABS, UL94-V0
red, similar to RAL 3020
approx. 190 g
EN 54-3 acoustic signaling device
Ø: 100 mm H: 77 mm
Ø: 100 mm H: 102 mm (incl. IP base)
Not suitable for use outdoors or in damp areas. Please use therefore the optional bases and ​
accessories (Part No. CWR, PS188, PS189). Use of the deep IP socket reduces the dB ​
output by an average of 4 dB. Replacement for Part No. 766225.
Accessories
CWR Base deep IP65, red
PS188 Base deep, O-Ring
PS189 Base deep, seal
Acoustic alarm signaling device, white
Approval: G 215015
1
As CWSO-RR-S1, but white color.
Technical Data
Color
Accessories
CWW Base deep IP 65, white
190
www.hls-austria.com
white, similar to RAL 9003
Alarm Devices
CWST-RR-S5
Conventional ENscape
1
Optical alarm signaling device EN 54-23 cat. W+C, red flash, red housing
Optical signaling device compliant with EN 54-23 for wall and ceiling mounting with red lamp color ​
and flat base. The signaling device is suitable for square signal ranges W-2.4-6.2 and cylindrical ​
signal ranges C-3-9.4 / C-6-8.2.
To help define your conventional Visual Alarm Devices (VADs) requirements in line with the EN54-​
23 standard, we have developed an easy to use online guide. Simply enter the room dimensions ​
and ambient light conditions and the guide will help your device selection:
http://www.kac.co.uk/EN54-device-chooser.htm
1
72
mm
97
mm
100 mm
Features
• EN 54-23 compliant
• C & W category
• Synchronous flash trigger
• Up to 6.2 m room width for wall mounting
• Up to 9.4 m room diameter for ceiling mounting
Technical Data
Operating voltage
Current consumption @ 24 V DC
Frequency of flash
Flash color
Connection terminal
Ambient temperature
Air humidity
Type of protection
Material
Category wall
Mounting height wall
Room width
Category ceiling
Mounting height ceiling
Room diameter
Color
Weight
Specification
Dimensions
2
3
12 ... 29 V DC
approx. 37 mA (@ DIN tone)
approx. 0.5 Hz
red
0.5 ... 2.5 mm2
-25 °C ... 70 °C
< 96 % (non-condensing)
IP21C, IP65 with CWR and accessories
PC/ABS, UL94-V0
PC, UL94-V0 (Lens)
W-2,4-6,2
2.4 m
6.2 m
C-3-9,4 / C-6-8,2
3m/6m
9,4 m / 8,2 m
base red, similar to RAL 3020
cap: transparent
approx. 164 g
EN 54-23 optical signaling device
Ø: 100 mm H: 72 mm
Ø: 100 mm H: 97 mm (incl. IP base)
4
5
6
7
8
9
Not suitable for use outdoors or in damp areas. Please use therefore the optional bases and ​
accessories (Part No. CWR, PS188, PS189). Replacement for Part No. 766420, 766422, ​
766410.
10
Accessories
CWR Base deep IP65, red
PS188 Base deep, O-Ring
PS189 Base deep, seal
CWST-RW-S5
11
12
Optical alarm signaling device, EN 54-23 cat. W+C, white flash, red housing
As CWST-RR-S5, but with a white flash.
1
13
CWST-WR-S5
Optical alarm signaling device EN 54-23 cat. W+C, red flash, white housing
14
As CWST-RR-S5, but in a white housing.
1
Technical Data
Color
base white, similar to RAL 9003
cap: transparent
Accessories
CWW Base deep IP65, white
PS188 Base deep, O-Ring
PS189 Base deep, seal
CWST-WW-S5
Optical alarm signaling device, EN 54-23 cat. W+C, white flash
As CWST-WR-S5, but with a white flash.
1
191
Alarm Devices
Conventional ENscape
Combined acoustic/optical alarm device EN 54-23 cat. W+C, red flash, red
housing
CWSS-RR-S5
Combined acoustic and optical alarm signaling device is EN 54-3 & EN 54-23 compliant, in red ​
housing, and offers a selection of 32 signal tones including the DIN tone and other country-specific ​
tones. All tones comply with EN 54-3. Tone configuration takes place via a 6-pin DIP switch. Up to ​
two different signal tones may be activated. The optical signaling device with red signal lamp is ​
suitable in accordance with EN 54-23 for square signal ranges W-2.4-6.0 and cylindrical signal ​
ranges C-3-8.9 / C-6-8.2. Signaling device with flat base, suitable for wall and ceiling mounting.
To help define your conventional Visual Alarm Devices (VADs) requirements in line with the EN54-​
23 standard, we have developed an easy to use online guide. Simply enter the room dimensions ​
and ambient light conditions and the guide will help your device selection:
http://www.kac.co.uk/EN54-device-chooser.htm
1
98
mm
122
mm
100 mm
Features
• EN 54-3 and 54-23 compliant
• Synchronous sound and flash trigger
• Volume adjustable to 2 levels at the device
• C & W category
• Signal range up to 6.0 m room width for wall ​
mounting
• Signal range up to 8.9 m room diameter for ​
ceiling mounting
Technical Data
Operating voltage
Current consumption @ 12 V DC
Current consumption @ 24 V DC
Sound level @ 12 V DC
Sound level @ 24 V DC
Frequency of flash
Flash color
Connection terminal
Ambient temperature
Air humidity
Type of protection
Material
Category wall
Mounting height wall
Room width
Category ceiling
Mounting height ceiling
Room diameter
Color
Weight
Specification
Dimensions
12 ... 29 V DC
approx. 63.9 mA (@ DIN tone)
approx. 69.9 mA (@ DIN tone)
97 dB(A) (@ DIN tone)
102.7 dB(A) (@ DIN tone)
approx. 0.5 Hz
red
0.5 ... 2.5 mm2
-25 °C ... 70 °C
< 96 % (non-condensing)
IP21C, IP65 with CWW and accessories
PC/ABS, UL94-V0
W-2,4-6,0
2.4 m
6m
C-3-8,9 / C-6-8,2
3m/6m
8,9 m / 8,2 m
red, similar to RAL 3020
cap: transparent
approx. 248 g
EN 54-3 acoustic signaling device
EN 54-23 optical signaling device
Ø: 100 mm H: 98 mm
Ø: 100 mm H: 122 mm (incl. IP base)
Not suitable for use outdoors or in damp areas. Please use therefore the optional bases and ​
accessories (Part No. CWR, PS188, PS189). Use of the deep IP socket reduces the dB ​
output by an average of 4 dB. Replacement for Part No. 766430.
Accessories
CWR Base deep IP 65, red
PS188 Base deep, O-Ring
PS189 Base deep, seal
CWSS-RW-S5
Combination signaling device EN 54-23 cat. W+C, white flash
As CWSS-RR-S5, but with a white flash.
1
CWSS-WR-S5
Combined acoustic/optical alarm device EN 54-23 cat. W+C, red flash,
white housing
As CWSS-RR-S5, but in a white housing.
Technical Data
Color
white, similar RAL 9003
cap: transparent
Accessories
CWW Base deep IP65, white
PS188 Base deep, O-Ring
PS189 Base deep, seal
CWSS-WW-S5
Combined acoustic/optical alarm device EN 54-23 cat. W+C, white flash,
white housing
As CWSS-WR-S5, but in a white housing with white flash.
192
www.hls-austria.com
Alarm Devices
CWST-WA-S7
Conventional ENscape
1
Optical alarm signaling device, amber flash
Optical alarm device for wall and ceiling mounting with amber signal flash and flat base.
The ​device does not comply with EN 54-23.
1
Technical Data
Operating voltage
Current consumption @ 24 V DC
Frequency of flash
Flash color
Ambient temperature
Air humidity
Type of protection
Material
Color
72
mm
97
mm
Weight
Dimensions
• Flat design
• Synchronous flash trigger
• Low alarm power
12 ... 29 V DC
approx. 3 mA (@ DIN tone)
approx. 0.5 Hz
yellow
-25 °C ... 70 °C
< 96 % (non-condensing)
IP21C, IP65 with CWW and accessories
PC/ABS, UL94-V0
PC, UL94-V0 (Lens)
base: white, similar RAL 9003
cap: amber
approx. 164 g
Ø: 100 mm H: 72 mm
Ø: 100 mm H: 97 mm (incl. IP base)
3
4
5
6
Not suitable for use outdoors or in damp areas. Please use therefore the optional bases and ​
accessories (Part No. CWW, PS188, PS189). Replacement for Part No. 766411.
100 mm
Features
2
Accessories
CWW Base deep IP 65, white
PS188 Base deep, O-Ring
PS189 Base deep, seal
7
8
9
CWST-RA-S7
1
Optical alarm signaling device, amber flash, red housing
As CWST-WA-S7 but in a red housing.
All tones comply with EN 54-3. Tone configuration takes place via a 6-pin DIP switch. The optical
signaling device with amber signal lamp is suitable for applications where a sounder is required as
the primary method of alarm, but a supplementary light indicator would also be of benefit.
Technical Data
Type of protection
Material
Color
10
11
IP21C, IP65 with CWR and accessories
PC/ABS, UL94-V0
PC, UL94-V0 (Lens)
base: red, similar RAL 3020
cap: amber
12
Not suitable for use outdoors or in damp areas. Please use therefore the optional bases and ​
accessories (Part No. CWR, PS188, PS189).
13
Accessories
CWR Base deep IP 65, red
PS188 Base deep, O-Ring
PS189 Base deep, seal
14
193
Alarm Devices
CWSS-WA-S7
Conventional ENscape
Combined acoustic/optical alarm device, red flash, white housing
Combined acoustic and optical alarm signaling device in white ​housing, and offers a selection of 32
signal tones including the DIN tone and other country-specific ​tones. All tones comply with EN
54-3. Tone configuration takes place via a 6-pin DIP switch. The optical signaling device with
amber signal lamp is ​suitable for applications where a sounder is required as the primary method
of alarm, but a supplementary light indicator would also be of benefit.
The ​device does not comply with EN 54-23.
98
mm
122
mm
100 mm
Features
• Approved to EN54-3 for sound
• 32 approved tones including bell tone
• LED technology & advanced optics provides
light indication at very low current draw
• Synchronisation of flash and sound.
• Operates on 12V and 24V systems
194
www.hls-austria.com
Technical Data
Operating voltage
Current consumption @ 24 V DC
Sound level @ 1 m
Flash color
Connection terminal
Ambient temperature
Air humidity
Type of protection
Material
Color
Weight
Specification
Dimensions
12 ... 29 V DC
approx. 22 mA (@ DIN tone 7)
107 dB(A) (@ DIN tone 23)
red
0.5 ... 2.5 mm2
-25 °C ... 70 °C
< 96 % (non-condensing)
IP21C, IP65 with CWW and accessories
PC/ABS, UL94-V0
base: white, similar RAL 9003
cap: amber
approx. 242 g
EN 54-3 acoustic signaling device
Ø: 100 mm H: 98 mm
Ø: 100 mm H: 122 mm (incl. IP base)
Not suitable for use outdoors or in damp areas. Please use therefore the optional bases and ​
accessories (Part No. CWW, PS188, PS189).
Accessories
CWW Base deep IP 65, white
PS188 Base deep, O-Ring
PS189 Base deep, seal
Alarm Devices
CWSS-RR-S3
1
Conventional ENscape
Combined acoustic/optical alarm device EN 54-3, open class, red flash,
red housing
1
Combined acoustic alarm signaling device is EN 54-3 compliant with additional optical display, in ​
red housing, and offers a selection of 32 signal tones including the DIN tone and other country-​
specific tones. All tones comply with EN 54-3. Tone configuration takes place via a 6-pin DIP ​
switch. Up to two different signal tones may be activated. Signaling device with flat base, suitable ​
for wall and ceiling mounting.
2
The integrated optical display with red signal flash is only authorized under EN 54-23 in open ​category O for 24–29 V DC operating voltage. Below 24 V DC, the device is classified as an ​acoustic
signaling device with additional display. To help define your conventional Visual Alarm ​Devices
(VADs) requirements in line with the EN54-23 standard, we have developed an easy to ​use online
guide. Simply enter the room dimensions and ambient light conditions and the guide will ​help your
device selection:
http://www.kac.co.uk/EN54-device-chooser.htm.
98
mm
122
mm
100 mm
Features
• EN 54-3 compliant
• Cat. O under EN 54-23
• Synchronous sound and flash trigger
• Volume adjustable to 2 levels at the device
• Suitable for wall and ceiling mounting
Technical Data
Operating voltage
Current consumption @ 12 V DC
Current consumption @ 24 V DC
Sound level @ 12 V DC
Sound level @ 24 V DC
Frequency of flash
Flash color
Connection terminal
Ambient temperature
Air humidity
Type of protection
Material
Color
Weight
Specification
Dimensions
3
4
5
12 ... 29 V DC
approx. 15.5 mA (@ DIN tone)
approx. 35.4 mA (@ DIN tone)
96.5 dB(A) (@ DIN tone)
102.5 dB(A) (@ DIN tone)
approx. 0.5 Hz
red
0.5 ... 2.5 mm2
-25 °C ... 70 °C
< 96 % (non-condensing)
IP 21C, IP 65 with CWR and accessories
PC/ABS, UL94-V0
red, similar RAL 3020
cap: transparent
approx. 236 g
EN 54-3 acoustic signaling device
EN 54-23 optical signaling device, (Cat O, 24 ... 29 V ​
DC)
Ø: 100 mm H: 98 mm
Ø: 100 mm H: 122 mm (incl. IP base)
6
7
8
9
10
Not suitable for use outdoors or in damp areas. Please use therefore the optional bases and ​
accessories (Part No. CWR, PS188, PS189). Use of the deep IP socket reduces the dB ​
output by an average of 4 dB. Replacement for Part No. 766240.
11
Accessories
CWR Base deep IP 65, red
PS188 Base deep, O-Ring
PS189 Base deep, seal
12
13
CWSS-WR-S3
Combined acoustic/optical alarm device EN 54-3, open class, red flash,
white housing
14
As CWSS-RR-S3, but in a white housing.
195
Alarm Devices
CWR
Conventional ENscape
Base deep IP 65, red
Base, red, for ENscape signaling device with IP 65 protection rating and sm cable entry.
1
Technical Data
Type of protection
Material
Color
Weight
Dimensions
IP65 (with accessories)
PC/ABS, UL94-V0
red, similar to RAL 3020
approx. 47 g
Ø: 100 mm H: 53 mm
5 pcs
Accessories
PS 188 Base deep, O-Ring
PS 189 Base deep, seal
SC076 Grounding bridge for deep base
CWW
Base deep IP 65, white
As CWR, but white color.
1
Technical Data
Color
white, similar to RAL 9003
5 pcs
PS188
O-Ring for deep base
Replacement O-ring for use with deep CWR or CWW base.
1
Technical Data
Material
Color
MBR 70
black
5 pcs
PS189
Seal for deep base
Seal for use with deep CWR or CWW base for IP 65 protection rating.
1
Technical Data
Material
Color
closed-cell neoprene
black
5 pcs
SC076
Ground jumper for deep base
Grounding strap for use with deep CWR or CWW base.
1
Technical Data
Material
5 pcs
196
www.hls-austria.com
Stainless steel
Alarm Devices
32
Intelligent Addressable IQ8Alarm
25
75
90
1
The IQ8Alarm range offers distinct advantages, which will surely convince every user straight ​
away.
2
112
112
60
IQ8Alarm enables IQ8Quad detector application with integrated alarm signaling and other advant­
ages. No matter whether multilingual speech alarm, flexible signal combination or user-friendly ​
programming interfaces, all these features are also available when using IQ8Alarm.
60
75
Features
• Completely bus supplied alarm device
• Powered loop compatible
• Low power consumption
• 5 different signaling device types - acoustic - ​
optical- acoustic / optical- acoustic / optical- ​
acoustic / optical / speech
• Multilingual speech alarm in 5 different ​languages
• Alarm signaling, evacuation, and test alarm can ​
each be programmed in different languages
• Up to 32 alarm devices for each powered loop
• Each alarm device has built-in isolator
• Individual control of the sounder and beacon
• Tones can be used for other purposes in addi­
tion to warning of fire, making the device ideal ​
for use in schools etc.
• Soft start option, ideal for hospitals and nursing ​
homes
Acoustic alarm signaling:
• Acoustic pressure up to 99 dB(A) @ 1 m
• Volume programmable in 8 steps via tools 8000
• Up to 26 different languages are available
• 20 different signaling tones, including DIN tone
• Speech alarm, 5 pre-programmed alarm texts ​
and other country-typical alarm signals
Advantages with IQ8Alarm at a glance:
3
Simple programming enabled by a standardized programming interface for all IQ8Systems ​
(IQ8Quad + IQ8Alarm) alarm signaling devices
-Voltage supply on the loop
4
-Time-tested, unobtrusive design
Signaling device in compliance with EN 54 with 20 different signaling tones including DIN tone in ​
compliance with DIN 33404-3
5
On the following pages, you will find more detailed information about IQ8Alarm features.
6
Please consider:
- Admissible maximum loop length
- Admissible maximum number of single alarm device types
- Maximum number of 127 bus devices for each loop
7
Systems requirements:
FACP IQ8Control from version V3.04
FACP FlexES Control
esserbus-Plus functionality
Programming software tools 8000 from version V1.09
8
Attention - an operation with the FACP'S 8000 C/M is not possible!!!
9
For upgrading 8000 C/M control units, IQ8Lumivox signaling devices must be used. If ​
required, please contact our returns department.
10
For checking the battery capacity of FACP, the value “quiescent current @ FACP battery“ can ​
be added.
11
Optical alarm signaling:
• Flash intensity equivalent to 3W Xenon flash ​
light
• Light intensity: max. 3.87 cd effective, max. 24 ​
cd peak
12
13
14
197
Alarm Devices
Intelligent Addressable IQ8Alarm
Intelligent Addressable IQ8Alarm
Country code
acc. to ISO
3166 -Alpha-2
Language
code acc.
to ISO 639-1 Evacuation 1
de
Germany
(DE)
en
Great Britain
(GB)
fr
France
(FR)
es
Spain
(ES)
it
Italy
(IT)
Evacuation 2
Alarm
Test-message
All-Clear
Dies ist ein
Feueralarm. Bitte
verlassen Sie das
Gebäude umgehend über die
nächsten Fluchtwege. Die Feuerwehr ist alarmiert.
Achtung, Achtung!
Dies ist eine Gefahrenmeldung. Bitte
verlassen Sie das
Gebäude über die
nächsten
Ausgänge.
Achtung, im Gebäude ist eine
Gefahrensituation
gemeldet worden.
Bitte bleiben Sie
ruhig, und warten
Sie auf weitere
Anweisungen.
Dies ist eine
Testdurchsage.
Die Gefahrensituation
ist jetzt behoben. Wir
entschuldigen uns
für jegliche
Unannehmlichkeiten.
This is a fire alarm.
Please leave the
building immediately by the nearest
available exit.
Attention please.
This is an emergency. Please leave the
building by the
nearest available exit.
An incident has
been reported in the
building. Please
await further
instructions.
This is a test
message.
No action is
required.
The emergency is
now cancelled. We
apologize for any
inconvenience.
Ceci est une alarme
incendie,veuillez
évacuer
immédiatement les
locaux par la sortie
la plus proche.
Votre attention s'il
vous plaît, ceci est
une alarme. Veuillez
évacuer les locaux
par la sortie la plus
proche.
Un incident est
signalé dans le
batiment. Merci de
garder votre calme
et attendez les
prochaines
instructions.
Ceci est un test.
L'alarme est à
présent annulée.
Veuillez nous excuser
pour le désagrément.
Esto es una alarma
de incendio.
Abandonen
por favor el edificio
inmediatamente
por la salida de
evacuación
más cercana.
Atención. Esto es
una emergencia.
Por favor
abandonen el
edificio por la
salida de
evacuación
más cercana.
Atención, se ha
reportado un
incidente
en el edificio.
Aguarden por favor
otras instrucciones.
Esto es un
mensaje
de prueba.
No se requiere
ninguna acción.
La emergencia ha
sido cancelada.
Pedimos disculpas
por las molestias
causadas.
Attenzione.
Allarme incendio.
Abbandonare
l'edificio tramite
l'uscita di
emergenza più
vicina.
Attenzione.
Allarme in corso.
Vi preghiamo di
recarvi presso
l'uscita di
emergenza più
vicina.
Attenzione.
E' stato rilevato un
allarme.Ulteriori
disposizioni vi
verranno
comunicate
appena possibile.
Attenzione.
E' in corso una
prova di allarme.
Non è richiesta
alcuna azione.
Attenzione. Cessato
allarme.La situazione
di normalità è stata
ripristinata.
Standard speech messages of IQ8Quad detectors and IQ8Alarm - for other languages also refer to the appendix!
No.
Description
Frequency
School bell
complex
2
FP 1063.1 Telecoms
BS 5839 Pt1
Alternating 800 / 970 Hz at 2 Hz
3
BS 5839 Pt1
Alternating 800 / 970 Hz at 1 Hz
f
4
BS 5839 Pt1
Intermittent 970 Hz at 1 Hz 0.5 sec.
f
5
BS 5839 Pt1
Intermittent 2850 Hz at 1 Hz 0.5 sec.
f
6
BS 5839 Pt1
Intermittent 970 Hz 1/4 sec. ON - 1 sec. OFF
f
7
BS 5839 Pt1
Continuous 970 Hz
f
8
BS 5839 Pt1
Sweep tone 800 Hz tp 970 Hz at 7 Hz
f
9
BS 5839 Pt1
Sweep tone 800 Hz to 970 Hz at 1 Hz
f
1.0 sec.
10
DIN Tone
DIN 33404 Part 3
1200 - 500 Hz at 1 Hz
f
1.0 sec.
11
French fire sound
554 Hz / 100 ms + 440 Hz / 400 ms + 10 %
f
12
NL - Slow Whoop
500 Hz - 1200 Hz at 3.5 sec. break of 0.5 sec.
f
13
US - Horn
Continuous 485 Hz
f
14
US - Horn with
Temporal Pattern
Intermittent 485 Hz
(0,5 sec. ON; 0.5 sec. OFF; 3 times; 1.5 sec. OFF; Repeat)
f
15
US - March
Time
Alternating 485 Hz
(0,25 sec. ON; 0.25 sec. OFF; Repeat)
f
16
US - Slow
Whoop
Sweep tone 500 Hz to 1200 Hz
(4.0 sec. ON; 0.5 sec. OFF; Repeat)
f
17
US - Siren
f
18
US - Hi/Lo
Sweep tone 600 Hz to 1200 Hz
(1,0 sec. ON, Repeat)
Alternating 100 Hz / 800 Hz
(0.25 sec. ON; Alternate; 0.25 sec. ON; Alternate; Repeat)
19
US - NFPA
Whoop
IMO
GA-Signal
Sweep tone 422 Hz to 775 Hz
(upwards sweep 0.85 sec.; 3 times; 1 sec. OFF; Repeat)
Intermittent 800 Hz (1,0 sec. ON; 1,0 sec.
OFF: 7 times; 2.0 sec. ON: 2.0 sec. OFF; Repeat)
f
20
IQ8Quad detectors and IQ8Alarm tone table
198
Pulse rate
1
www.hls-austria.com
complex
f
0.25 sec.
0.25 sec.
t
0.5 sec.
0.5 sec.
t
0.5 sec.
1.5 sec.
0.5 sec.
0.5 sec.
t
1.5 sec.
0.5 sec.
0.25 sec.
t
1.0 sec.
t
t
10 ms
t
t
t
0.4 sec. 0.1 sec.
t
3.5 sec.
0.5 sec.
t
t
0.5 sec.
1.5 sec.
0.5 sec.
t
0.25 sec.
0.25 sec.
t
4.0 sec. 0.5 sec.
t
1.0 sec.
t
f
0.25 sec.
0.25 sec.
0.85 sec.
t
1.0 sec.
t
f
1.0 sec.
1.0 sec.
t
Alarm Devices
Intelligent Addressable IQ8Alarm
1
IQ8Alarm - Acoustical Alarm Devices
Features
• Completely bus supplied alarm device
• Powered loop compatible
• Low power consumption
• Up to 32 alarm devices for each powered loop
• Each alarm device has built-in isolator
• Tones can be used for other purposes in addi­
tion to warning of fire, making the device ideal ​
for use in schools etc.
• Soft start option, ideal for hospitals and nursing ​
homes
Acoustic alarm signaling (dependent on type):
• Acoustic pressure up to 99 dB(A) @ 1 m
• Volume programmable in 8 steps via tools 8000
• Up to 26 different languages are available
• 20 different signaling tones, including DIN tone
• Multilingual speech alarm in 5 different ​languages
• Alarm signaling, evacuation, and test alarm can ​
each be programmed in different languages
• Speech alarm, 5 pre-programmed alarm texts ​
and other country-typical alarm signals
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Quiescent current @ FACP battery
Load factor
Sound level
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Weight
Specification
Dimensions
Declaration of Performance
2
8 ... 42 V DC (via powered loop)
approx. 55 μA
approx. 300 μA @ 42 V
3
97 dB(A) +/- 2 dB @ 1 m
-5 °C ... 50 °C
-10 °C ... 55 °C
< 95 % (non-condensing)
IP 30
(IP 65 with socket 806201 / 806202)
ABS plastic
approx. 300 g
EN 54-3 acoustic signaling device
EN 54-3 acoustic speech signaling device (Q2/2011)
Ø: 112 mm D: 75 mm
Ø: 112 mm D: 90 mm (with IP 65 base)
DoP-20213130701
3
4
5
6
7
8
807205
IQ8Alarm/So signaler with isolator, white
1
Approval: VdS
9
Addressable, completely bus supplied and short circuit / open circuit resilient alarm signaling ​
device in compliance with EN 54-3 with up to 20 different programmable signaling tones including ​
DIN tone in accordance with DIN 33404 Part 3 for acoustic alarm signaling. The volume can be set ​
to 8 different levels. Its flat design enables optimum adaptation to the environments. It is made of ​
shock and scratch resistant plastic. Optionally, bases Part No. 806201 and 806202 with side cable ​
entry and weatherproof protection can be installed.
Technical Data
Color
Specification
10
11
white, similar to RAL 9010
EN 54-3 acoustic signaling device
EN 54-3
12
Accessories
806201 IP65 base, white
13
807206
IQ8Alarm/So signaler with isolator, red
14
1
Approval: VdS
Same as 807205, but red.
Technical Data
Color
Specification
red, similar to RAL 3020
EN 54-3 acoustic signaling device
EN 54-3
Accessories
806202 IP65 base, red
199
Alarm Devices
807322
Intelligent Addressable IQ8Alarm
IQ8Alarm/Sp signaler with isolator, white
1
Approval: VdS
Same as 807205, but with additional speech alarm function.
Technical Data
Color
Specification
white, similar to RAL 9010
EN 54-3 acoustic signaling device
EN 54-3 acoustic speech signaling device (Q2/2011)
Programmed with an individual selection of up to 5 national languages
Accessories
806201 IP 65 base, white
807322.SV98
IQ8Alarm/Sp signaler with isolator, white, composed version
1
Approval: VdS
Same as 807322, but with individual text and/or sounds. The maximum recording time per device ​
is 169 seconds.
Technical Data
Specification
EN 54-3
EN 54-3
When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in ​
“Order form for individual combination of languages” printed in the appendix.
Cancellations or returns are not possible.
Programmed with an individual selection of up to 5 national languages
Accessories
806201 IP65 base, white
200
www.hls-austria.com
Alarm Devices
807332
Intelligent Addressable IQ8Alarm
1
IQ8Alarm/Sp signaler with isolator, red
1
Approval: VdS
Same as 807322, but red.
Technical Data
Color
Specification
2
red, similar to RAL 3020
EN 54-3 acoustic signaling device
EN 54-3 acoustic speech signaling device (Q2/2011)
3
Programmed with an individual selection of up to 5 national languages
4
Accessories
806202 IP65 base, red
5
807332.SV98
IQ8Alarm/Sp signaler with isolator, red, composed version
6
1
Approval: VdS
Same as 807322.SV98, but with an individual combination of up to 5 languages, see special order ​
form in the appendix.
Technical Data
Specification
7
EN 54-3
EN 54-3
8
When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in ​
“Order form for individual combination of languages” printed in the appendix.
Cancellations or returns are not possible.
807332.SV99
9
Accessories
806202 IP65 base, red
10
IQ8Alarm/Sp signaler with isolator, red, customized version
11
1
Approval: VdS
Same as 807322, but with individual text and/or sounds. The maximum recording time per ​device
is 169 seconds.
Technical Data
Specification
12
13
EN 54-3
EN 54-3
When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in ​
“Order form for individual combination of languages” printed in the appendix.
Costs for the recording of customer specific texts and/or tones can be obtained on request.
Cancellations or returns are not possible.
14
Accessories
806202 IP65 base, red
201
Alarm Devices
Intelligent Addressable IQ8Alarm
IQ8Alarm - Combined Alarm and Speech Signaling Devices
Features
• Completely bus supplied alarm device
• Powered loop compatible
• Low power consumption
• Up to 32 alarm devices for each powered loop
• Each alarm device has built-in isolator
• Tones can be used for other purposes in addi­
tion to warning of fire, making the device ideal ​
for use in schools etc.
• Soft start option, ideal for hospitals and nursing ​
homes
Acoustic alarm signaling (dependent on type):
• Acoustic pressure up to 99 dB(A) @ 1 m
• Volume programmable in 8 steps via tools 8000
• Up to 26 different languages are available
• 20 different signaling tones, including DIN tone
• Multilingual speech alarm in 5 different ​languages
• Alarm signaling, evacuation, and test alarm can ​
each be programmed in different languages
• Speech alarm, 5 pre-programmed alarm texts ​
and other country-typical alarm signals
Optical alarm signaling:
• Flash intensity equivalent to 3W Xenon flash ​
light
807224
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Quiescent current @ FACP battery
Load factor
Sound level
Frequency of flash
Lighting energy
Luminous intensity
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Weight
Specification
Dimensions
Declaration of Performance
8 ... 42 V DC (via powered loop)
approx. 55 μA
approx. 300 μA @ 42 V
3
97 dB(A) +/- 2 dB @ 1 m
approx. 3 Hz
approx. 3 Y
max. 24.4 cd peak/ 4.1 cd effektive (red flash)
-10 °C ... 50 °C
-10 °C ... 55 °C
< 95 % (non-condensing)
IP 30
(IP 65 with socket 806201 / 806202)
ABS plastic
approx. 300 g
EN 54-3 acoustic signaling device
EN 54-3 acoustic speech signaling device (Q2/2011)
Ø: 112 mm D: 75 mm
Ø: 112 mm D: 90 mm (with IP 65 base)
DoP-20213130701
IQ8Alarm/FSo signaler with isolator, red
1
Approval: VdS
Addressable, completely bus supplied and short circuit / open circuit resilient alarm signaling ​
device in compliance with EN 54-3 with up to 20 different programmable signaling tones including ​
DIN tone in accordance with DIN 33404 Part 3 for acoustic and optical alarm signaling. The ​volume
can be set to 8 different levels. Its flat design enables optimum adaptation to the environ­ments. It is
made of shock and scratch resistant plastic. Optionally, bases (Part no. 806201 white ​or 806202
red) with side cable entry and weatherproof protection (IP65) can be installed.
Technical Data
Luminous intensity
Color
Specification
Accessories
806202 IP65 base, red
202
www.hls-austria.com
max. 24.4 cd peak/ 4.1 cd effektive (red flash)
red, similar to RAL 3020
EN 54-3 acoustic signaling device
EN 54-3
Alarm Devices
807372
Intelligent Addressable IQ8Alarm
1
IQ8Alarm/FSp signaler with isolator, red
1
Approval: VdS
Same as in 807224, but with programmed speech alarm for powered loop connection.
2
Technical Data
Luminous intensity
Color
Specification
3
max. 24.4 cd peak/ 4.1 cd effektive (red flash)
red, similar to RAL 3020
EN 54-3 acoustic signaling device
EN 54-3 acoustic speech signaling device (Q2/2011)
4
Programmed with 5 languages: German, English, French, Spanish and Italian.
Accessories
806202 IP65 base, red
5
6
807372.SV98
IQ8Alarm/FSp signaler with isolator, red, composed version
1
Approval: VdS
7
Same as 807372, but with an individual combination of up to 5 languages, see special order form ​
in the appendix.
Technical Data
Color
Specification
8
red, similar to RAL 3020
EN 54-3
EN 54-3
9
When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in ​
“Order form for individual combination of languages” printed in the appendix.
Cancellations or returns are not possible.
10
Programmed with 5 languages in accordance with composed combination.
807372.SV99
Accessories
806202 IP65 base, red
11
IQ8Alarm/FSp signaler with isolator, red, customized version
12
1
Approval: VdS
Same as 807372, but with individual texts and/or sounds. The maximum recording time per device ​
is 169 seconds.
13
Technical Data
Color
Specification
14
red, similar to RAL 3020
EN 54-3
EN 54-3
When ordering, please note the "Ordering information for IQ8Quad and IQ8Alarm" and fill in ​
“Order form for individual combination of languages” printed in the appendix.
Costs for the recording of customer specific texts and/or tones can be obtained on request.
Cancellations or returns are not possible.
Programmed according to customer specifications.
Accessories
806202 IP65 base, red
203
Alarm Devices
Intelligent Addressable IQ8Alarm
IQ8Alarm - Optical Alarm Signaling Devices
807212
IQ8Alarm/F signaler with isolator, amber flash
1
Approval: VdS
Addressable, completely bus supplied and short circuit / open circuit resilient alarm signaling ​
device for optical alarm signaling. Its flat and unobtrusive design enables optimum adaptation to ​
the environments.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Quiescent current @ FACP battery
Load factor
Frequency of flash
Lighting energy
Luminous intensity
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
Declaration of Performance
8 ... 42 V DC (via powered loop)
approx. 55 μA
approx. 300 μA @ 42 V
3
approx. 3 Hz
approx. 3 Y
max. 24 cd peak/ 3.87 cd effective
-10 °C ... 50 °C
-10 °C ... 55 °C
< 95 % (non-condensing)
IP 30
IP 65 (with base 806201/806202)
ABS plastic
base: white, similar to RAL 9010
cap: amber
approx. 300 g
Ø: 112 mm D: 75 mm
Ø: 112 mm D: 90 mm (with IP 65 base)
DoP-20213130701
806201 IP65 base, white
807213
IQ8Alarm/F signaler with isolator, blue/green/white flash
1
Approval: VdS
Same as 807212, but transparent, blue and green.
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Quiescent current @ FACP battery
Load factor
Frequency of flash
Lighting energy
Luminous intensity
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
Declaration of Performance
Replacement: 807214WW
806201 IP65 base, white
204
www.hls-austria.com
8 ... 42 V DC (via powered loop)
approx. 55 μA
approx. 300 μA @ 42 V
3
approx. 3 Hz
approx. 3 Y
transparent: max. 17.39 cd peak/ 2.16 cd effektive
blue: max 5,06 cd peak/0,62 cd effektive
green: max. 2,72 cd peak/0,33 cd effektive
-10 °C ... 50 °C
-10 °C ... 55 °C
< 95 % (non-condensing)
IP 30
IP 65 (with base 806201/806202)
ABS plastic
base: white, similar to RAL 9010
cap: blue, green, transparent
approx. 300 g
Ø: 112 mm D: 75 mm
Ø: 112 mm D: 90 mm (with IP 65 base)
DoP-20213130701
Alarm Devices
Intelligent Addressable IQ8Alarm
1
807214WW
Optical alarm signaling device IQ8Alarm EN 54-23 Kat. W, white f​ lash
Approval: requested
2
1
Optical signaling device compliant with EN 54-23 for wall mounting with white signal flash and flat ​
base. The signaling device is suitable for square signal ranges W-2.4-5.0.
Features
• Completely bus supplied alarm device
• Powered loop compatible
• Low power consumption
• Up to 32 alarm devices for each powered loop
• Each alarm device has built-in isolator
• EN 54-23 compliant
• W category
• Synchronous flash control
• Up to 5 m, room width
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Load factor
Frequency of flash
Flash color
Ambient temperature
Air humidity
Type of protection
Material
Category wall
Mounting height wall
Room width
Color
Weight
Specification
Dimensions
3
8 ... 42 V DC
approx. 55 μA
3
approx. 0.5 Hz(factory) /1 Hz
white
-25 °C ... 70 °C
< 95 % (non-condensing)
IP 41
Flash lamp PC
W-2,4-5,0 (factory)
2.4 m
5m
white, similar to RAL 9010
cap: transparent
approx. 275 g (with base)
EN 54-23 optical alarm signaling device
Ø: 112 mm H: 75 mm
4
5
6
7
Replacement for 807213
8
807214RR
Optical alarm signaling device IQ8Alarm EN 54-23 Kat. W, red f​ lash
Approval: requested
9
Optical signaling device compliant with EN 54-23 for wall mounting with red signal flash and flat ​
base. The signaling device is suitable for square signal ranges W-2.4-5.0.
10
1
Features
• Completely bus supplied alarm device
• Powered loop compatible
• Low power consumption
• Up to 32 alarm devices for each powered loop
• Each alarm device has built-in isolator
• EN 54-23 compliant
• W category
• Synchronous flash control
• Up to 5 m, room width
Technical Data
Operating voltage
Quiescent current @ 19 V DC
Load factor
Frequency of flash
Flash color
Ambient temperature
Air humidity
Type of protection
Material
Category wall
Mounting height wall
Room width
Color
Weight
Specification
Dimensions
11
8 ... 42 V DC
approx. 55 μA
3
approx. 0.5 Hz(factory) /1 Hz
red
-25 °C ... 70 °C
< 95 % (non-condensing)
IP 41
Flash lamo PC
W-2,4-5,0 (factory)
2.4 m
5m
red, similar to RAL 3020
cap: transparent
approx. 275 g (with base)
EN 54-23 optical alarm signaling device
Ø: 112 mm H: 75 mm
12
13
14
Replacement for 807214
205
Alarm Devices
Intelligent Addressable IQ8Alarm
Accessories IQ8Alarm
806201
IQ8Alarm IP 65 base, white
1
White base, for IQ8Alarm device with protection type IP65 and surface mount cable entry.
Technical Data
Type of protection
Color
IP 65
white, similar to RAL 9010
806202
IQ8Alarm IP 65 base, red
1
Red base, for IQ8Alarm device with protection type IP65 and surface mount cable entry.
Technical Data
Type of protection
Color
IP 65
red, similar to RAL 3020
767800
Mounting bracket for lintel installation
1
Mounting bracket for all bases/detectors of the IQ8Quad group, series 9x00, RAS 2103 for ​
IQ8Alarm including all alarm devices.
The distance between the mounting holes is 6 cm and the diameter is about 5 mm. Detector side L ​
x W 175 x 90 mm; Wall side H x W 65 x 90 mm.
Technical Data
Material
Color
Mounting bracket and installation material
206
www.hls-austria.com
aluminum
white, similar to RAL 9010
Alarm Devices
Conventional
1
Intrinsically Safe
045040
Ex signaling device DS10, 12 V DC
2
1
Approval: VdS (FDT)
3
The sound generator is especially suitable for hazardous industrial areas (zone 2 and 22). The ​
robust aluminum die-cast housing is resistant to chemicals and environmental factors. The DS10 ​
complies with the technical requirements of DIN 33404 - 3 "hazard signals for workplaces".
Features
• 9 tone sequences can be programmed:
• Continuous tone
• Alternating tone
• Intermittent tone
• Siren
• Fire alarm (different national regulations taken ​
into account)
Technical Data
Ex-category
Explosion protection
Operating voltage
Current consumption @ 12 V DC
Sound level
Ambient temperature
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
Specification
Dimensions
4
II 3GD
EEx nA II T5
11 ... 14 V DC
10 V DC
approx. 300 mA
110 dB (A) +- 3 dB (A)
-25 °C ... 55 °C
-40 °C ... 70 °C
< 90 % (non-condensing)
IP 66, IP 67
aluminum die cast
red, similar to RAL 3000
approx. 1.95 kg
EN 54-3
W: 150 mm H: 150 mm D: 143 mm
5
6
7
8
According to the conformity declaration, the alarm devices can be used in zones 2 and 22.
See tone table on our download website.
9
766253
Ex sounder, 12 V DC
1
KEMA 99 ATEX 7906 design certificate
10
The ex sounder is especially suitable for application in hazardous areas at industrial workplaces ​
category 2G or 3G (formerly zones 1 and 2) and complies with the technical requirements of DIN ​
33404 - 3. The robust aluminum die-cast housing is resistant to chemicals and environmental ​
factors.
Features
• 32 tone sequences can be programmed:
• Quartz controlled sound synchronization
• ATEX approved
• LM6 aluminum die-cast housing
• Self-extinguishing aluminum cone, similar to UL ​
94 VO
Technical Data
EC-type examination certificate
Explosion protection
Operating voltage
Current consumption
Current consumption @ 12 V DC
Sound level
Ambient temperature
Storage temperature
Air humidity
Type of protection
Material
Color
Weight
Dimensions
11
12
KEMA 99ATEX 7906
II 2G Ex de IIC T4
12 V DC
typ. 195 mA;
approx. 195 mA
110 dB(A) ± 3 dB @ 1 m (depending on signaling ​
type)
-50 °C ... 55 °C
-50 °C ... 70 °C
< 90 % (non-condensing)
IP67
aluminum die cast LM6
red, similar to RAL 3000
approx. 3.16 kg
Ø: 181 mm L: 263 mm
13
14
According to the conformity declaration, the alarm devices can be used in zones 2 and 22.
See tone table on our download website.
207
Alarm Devices
Remote Indicators
Remote Indicators
• Shapely, light-weight and compact design
• Prism with all around 180° visible LEDs with a ​
wide area of illumination and high on/off contrast
These indicators are used primarily for signaling alarms of smoke detectors installed above ​
suspended ceilings, between floors or in other inaccessible locations. The indicators have an ​
elegant plastic housing with a clearly visible illuminated field. It comprises two parts - the base ​
which is installed onto a wall or soffit and the lid which is fitted to the base with a clip plug.
781814
Remote indicator for Series 9000, 9200 and IQ8Quad, red
1
Red prism is continuously or pulsed illuminated by 3 LEDs.
Features
Features
• 3 continuously or pulsed LEDs
• Power-saving compact indicator
Cable length of the remote indicators to detector base or voltage supply max. 100 m.
Technical Data
Operating voltage
Current consumption
Alarm display
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
1.8 V DC
approx. 9 mA
3 red LEDs
-20 °C ... 70 °C
-35 °C ... 85 °C
< 95 % (non-condensing)
IP 50
ABS plastic
white, similar to RAL 9010
approx. 60 g
W: 85 mm H: 82 mm D: 27 mm
Detectors series IQ8Quad
- Standard base Part No. 805590 required for series IQ8Quad
- max. 1 remote indicator per detector
- max. 60 remote indicators per zone (with max. 30 detectors)
- Indicator flashes if activated (Pulse frequency approx.1 Hz)
801824
Remote indicator esserbus-PLus for detector series 9200 and ​IQ8Quad, red
1
Red prism is illuminated by 4 pulsed LEDs for operation on esserbus and esserbus-PLus to ​
increase the energy efficiency.
Features
• 4 pulsed LEDs
• Ultra power-saving compact indicator
• Powered loop alarm device
Technical Data
Operating voltage
Quiescent current @ 12 V DC
Alarm current
Frequency of flash
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
8 ... 42 V DC
approx. 0.007 mA
150 µA
approx. 1.5 Hz
-20 °C ... 70 °C
-35 °C ... 85 °C
< 95 % (non-condensing)
IP 50
ABS plastic
white, similar to RAL 9010
approx. 60 g
W: 85 mm H: 82 mm D: 27 mm
Detectors series IQ8Quad
- Standard base Part No. 805590 required for series IQ8Quad
- max.3 remote indicator per detector
- max. 103 remote indicators per loop
208
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
11
Door Release System
Automatic Door Systems
Door Holding Devices
Triggering Devices
210-212 12
213-217
218
13
14
209
Door Release System
Features
• Low profile design
• Easy cable entry & exit
• Electronic connection via a terminal clamp
• Door retainers have an integrate release button
• The door retainer can be mounted to the wall, to
the floor or to the ceiling behind the door. Due to
the large product range almost any requirement
profile can be met
• The counterpart is the armature (keeper plate)
which is mounted on the door
• Door retainer magnets are delivered with a
suitable keeper plate
• Electrical Protection IP54
• Anti-remanence pin
• Integrated reverse polarity and spark suppression diode
• Plastic parts consist of Bayblend material with
30% PA6 glass fiber
210
www.hls-austria.com
Automatic Door Systems
Automatic door closing systems for the demarcation of buildings and objects in closed fire ​compartments for the protection of people and valuables in case of fire.
Automatic door systems consist of triggering devices and locking devices.
In the event of fire, signals created by automatic triggering device cause a ​release of locking
device. Actuation by the manual triggering device also leads to ​release of locking device.
Fire doors close and prevent the spreading of fires and of any present smoke to ​bordering areas in
a building. This way, fire and dangerous fire aerosols are contained ​and human life as well as
valuables are protected.
Locking device consists of e.g. a clamping magnet with corresponding anchor plate and/​or of an
automatic door closer. Triggering device consists of a controller, fire detector and release key
pushbutton (manual triggering device).
In terms of building directives in Germany, automatic door systems are subject to approval by
Deutschen ​Institut for Bautechnik in Berlin and need a system authorization (for this, see certificates ​of approval from the DIBt).
The door holding magnets from Honeywell product line are generally vacuum cast and feature
IP64 protection class by the basic device.
Door holding magnets are fitted with an integral manual release button, allowing the door to be
closed without operating the fire alarm.
All the electromagnets are designed to comply with the latest requirements of EN1155 and DIN
EN14637.
Door Release System
Automatic Door Systems
1
Connection Examples
2
3
4
5
6
Release
pushbutton
7
8
9
10
11
12
13
14
Release
pushbutton
Release
pushbutton
211
Door Release System
Release
pushbutton
Release
pushbutton
212
www.hls-austria.com
Automatic Door Systems
Door Release System
Door Holding Devices
1
Holding Magnets with 400 N Holding Force
The door holding magnets from this product line are generally vacuum cast and feature ​IP65
protection class by the basic device. The magnets are quality-controlled and are ​subjected to
sampling tests twice per year by the VdS. In addition, all dimensions are in ​accordance with European specifications and tested in compliance with the EN1155.
2
3
960120
Door magnet with release button incl. flexible anchor, 400 N
1
Release button changeable to the left or right from the base. Cable entry is ​possible from behind
the unit, as well as through the base, left or right side using ​included grommets.
In combination with angled mounting plates the unit can be installed to either floor or wall.
4
Integrated reverse-polarity protection diode and spark supressing diode.
Technical Data
Operating voltage
Power consumption
Type of protection
Dimensions
CE certificate
5
24 V DC
1.6 W
IP54 (magnet); IP42 (connection)
W: 85 mm H: 110 mm D: 38 mm
0786-CPD-20435
6
7
960121
Door magnet with distance pipe incl. flexible anchor, 400 N, 175 mm
1
Approval: VdS
8
Magnet rotary head is fully rotational and is thus suitable for both floor ​and wall installations.
Customer may shorten distance pipe if necessary.
Integrated reverse-polarity protection diode and spark supressing diode.
Manual release button on pipe available.
Wall distance: 175 mm
Floor distance: 150 mm
9
Technical Data
Operating voltage
Power consumption
Type of protection
Dimensions
CE certificate
960122
10
24 V DC
1.6 W
IP54 (magnet); IP42 (connection)
W: 90 mm H: 80 mm Distance: 150/175 mm
0786-CPD-20435
11
12
Door magnet with distance pipe incl. flexible anchor, 400 N, 325 mm
1
As 960121, but with wall distance 325 mm or floor distance 300 mm.
Technical Data
Dimensions
960130
13
W: 90 mm H: 80 mm Distance: 300/325 mm
14
Door magnet with distance pipe incl. flexible anchor, 400 N, 475 mm
1
As 960121, but with wall distance 475 mm or floor distance 450 mm.
Technical Data
Dimensions
960124
W: 90 mm H: 80 mm Distance: 450/475 mm
Door magnet w/o release button incl. flexible anchor, 400 N
1
Version with terminal clamp and installation plate.
Integrated reverse-polarity protection diode and spark supressing diode.
Suitable for wall installation.
Technical Data
Operating voltage
Power consumption
Type of protection
Dimensions
CE certificate
24 V DC
1.6 W
IP54 (magnet); IP42 (connection)
W: 55 mm H: 55 mm D: 33 mm
0786-CPD-20435
213
Door Release System
Door Holding Devices
Holding Magnets with 490 N Holding Force
960126
Wall mounted door magnet w/o release button, 490 N
1
Wall mounted direct current door magnet.
Technical Data
Operating voltage
Power consumption
Dimensions
Approvals
767010
24 V DC
1.5 W
W: 75 mm H: 116 mm D: 43 mm
EN155, CPR, EN14637
Door retainer DH50-N490-WM
1
Door retainer with polarity reversal protection and connecting terminal including fixing plate for wall
mounting.
Technical Data
Operating voltage
Power consumption
Dimensions
24 V DC
1.5 W
Ø: 50 mm H: 30 mm
Holding Magnets with 800 N Holding Force
960119
Door magnet with release button incl. flexible anchor, 800 N
1
Release button changeable to the left or right from the base. Cable entry is ​possible from behind
the unit, as well as through the base, left or right side using ​included grommets.
In combination with angled mounting plates the unit can be installed to either floor or wall.
Integrated reverse-polarity protection diode and spark supressing diode.
Technical Data
Operating voltage
Power consumption
Type of protection
Dimensions
Approvals
214
www.hls-austria.com
24 V DC
2.2 W
IP54 (magnet); IP42 (connection)
W: 85 mm H: 110 mm D: 38 mm
EN155, CPR, EN14637
Door Release System
960127
Door Holding Devices
Wall and floor swivel bracket for door magnet 960119 and 960120, angled,
150 mm
1
1
This swivel bracket is specially intended for use with 960120 door magnet and thus allows floor or
wall installa­tion by means of distance pipe.
Technical Data
Dimensions
Weight
960128
2
W: 100 mm H: 150 mm D: 140 mm
approx. 0.65 kg
3
4
Wall and floor swivel bracket for door magnet 960119 and 960120,
angled, 300 mm
1
As 960127, but with 300 mm pipe length.
Technical Data
Dimensions
Weight
5
W: 100 mm H: 300 mm D: 140 mm
approx. 1 kg
6
7
960129
Floor mounted bracket for door magnet 960119 and 960120
8
1
This brackt is especially intended for 960119 and 960120 door magnet. Thus a parallel door installation is possible. Magnet ​can either be installed within the side panels (to protect from vandalism)
or adjacent to the ​side panels (standard). Due to the increased gauge of steel used, this base is
suitable for ​heavy use (schools etc).
Technical Data
Dimensions
Weight
9
W: 95 mm H: 128 mm D: 80 mm
approx. 0.65 kg
10
11
Explosion-Proof
12
767153
Ex door magnet, 1588 N
Approval: VdS, TÜV ATEX
13
Explosion-proof and encapsulated holding magnet for explosion endangered areas.
Wall-mounted with cable entry via cable gland.
Technical Data
Operating voltage
Power consumption
Holding force
Ambient temperature
Ex-category
Explosion protection
Type of protection
Dimentions
EC-type examination certificate
14
24 V DC
3W
1588 N
0 °C ... 35 °C
II 2G (gas) and 2D (dust)
EExme II T6 (gas) and T73°C IP6X (dust)
IP56
W: 130 mm H: 117 mm D: 106 mm
TÜV01 ATEX 1778 X
Delivery without anchor plate.
on demand
Approved anchor plates must be used in EX zones.
215
Door Release System
Door Holding Devices
Keeper Plates
960110
Flexible keeper plate for door magnets, Ø 55 mm
1
The flexible keeper plate is designed for doors with an angle. The anchor plate is 60° adjustable
and fixable in each direction through an articulated joint. The surface is grounded and protected
against corrosion.
Technical Data
Weight
Dimensions
767030
approx. 0.15 kg
Ø: 55 mm W: 55 mm H: 55 mm D: 50 mm
Anchor plate DH50-AP-S
1
Fixing plate for door retainers with a diameter of 50 mm.
Technical Data
Dimensions
767031
Ø: 50 mm W: 55 mm H: 55 mm D: 18 mm
Anchor plate DH70-AP-S
As 767030, but with Ø 70 mm anchor plate.
Technical Data
Dimensions
216
www.hls-austria.com
Ø: 70 mm W: 75 mm H: 75 mm D: 26 mm
Door Release System
Door Holding Devices
Power Supply Units for Door Release System
765612
1
Power supply unit for automatic door release systems, 12 V, 3 A
2
1
Surface mount housing for fire door release systems.
Technical Data
Rated voltage
Rated frequency
Output voltage
Output current
Ambient temperature
Storage temperature
Air humidity
Type of protection
Housing
Color
Weight
Dimensions
230 V AC/115 V AC
50 ... 60 Hz
12 V DC
max. 3 A
-10 °C ... 40 °C
-20 °C ... 85 °C
≤ 95 % (without condensation)
IP20
ABS plastic
white, similar to RAL 9010
approx. 800 g
W: 195 mm H: 140 mm D: 70 mm
3
4
5
6
765624
Power supply unit for automatic door release systems, 24 V, 1.5 A
1
7
As 765612, but with 24 Volt.
Technical Data
Output voltage
Output current
24 V DC
max 1.5 A
8
9
10
11
12
13
14
217
Door Release System
Triggering Devices
Release Pushbuttons
767813.10
Surface mount release pushbutton for automatic door release system, ​
German
1
Surface mount release key for manual actuation of locking devices with double rocker ​switch
insert.
Technical Data
Contact load
Type of protection
Housing
Color
Weight
767814.10
250 V AC/10 A
IP44
ABS plastic
gray, similar to RAL 7035
approx. 120 g
Flush mount release pushbutton for automatic door release system, ​
German
1
Flush mount release pushbutton for manual actuation of locking devices with double rocker switch ​
insert.
Technical Data
Contact load
Type of protection
Housing
Color
Weight
796349
250 V AC/10 A
IP44
ABS plastic
white
approx. 95 g
Label for release pushbutton
1
Red sticker label for release pushbutton 767813 and 767814.
10 pcs
218
www.hls-austria.com
1
2
3
4
5
6
7
8
9
10
11
Installation & Service
Installation Accessories
Housings
220-224 12
225-226
13
14
219
Installation & Service
Installation Accessories
Surge Protection
764730
OVP module for TTY interfaces and conventional zones
1
Overvoltage protection module as 4-pin, rail-mounted device.
Space-saving combined surge protector module for the protection of two wire pairs of symmetrical ​
interfaces with electrical isolation.
Technical Data
Rated voltage
Rated current
max. cont. operating voltage a.c.
max. cont. operating voltage d.c.
Nom. discharge current (80/20)/line
Total nom. discharge current
Total lightning imp. current (10/350)
Lightning imp. current (10/350)/line
Ambient temperature
Air humidity
Type of protection
24 V
1 A @ 45 °C
23.3 V AC
33 V DC
10000 A
20 kA
10 kA
2.5 kA
-40 °C ... 85 °C
< 95 % (non-condensing)
IP 20
Low resistance ground connection is a must for proper surge protection functioning.
Accessories
764737 Base for overvoltage protection module
764731
OVP module for essernet and RS485 interfaces
1
Space-saving combined surge protector with LifeCheck for the protection of one wire of radio-​
frequency bus systems, with either direct or indirect shield grounding.
Technical Data
Rated voltage
Rated current
max. cont. operating voltage a.c.
max. cont. operating voltage d.c.
Nom. discharge current (80/20)/line
Total nom. discharge current
Total lightning imp. current (10/350)
Lightning imp. current (10/350)/line
Ambient temperature
Air humidity
Type of protection
5V
1 A @ 45 °C
4.2 V AC
6 V DC
10000 A
20 kA
9 kA
2.5 kA
-40 °C ... 85 °C
< 95 % (non-condensing)
IP 20
Accessories
764737 Base for overvoltage protection module
764732
OVP module including base support for 230 V power supply line
1
Two-pin surge protector comprising base element and connected protection module, with potential-​
free telecommunications contact for independent fault forwarding.
Technical Data
Rated voltage
max. cont. operating voltage a.c.
max. cont. operating voltage d.c.
Nominal load current a.c.
Total discharge current (8/20) [L+N-PE]
Combined impulse
Combined impulse [L+N-PE]
Voltage protection level [L/N-PE]
Voltage protection level [L-N]
Response time [L/N-PE]
Response time [L-N]
Ambient temperature
Air humidity
Type of protection
230 V AC
255 V AC
255 V DC
25 A
5 kA
6 kV
10 kV
≤ 1500 V
≤ 1250 V
≤ 100 ns
≤ 25 ns
-40 °C ... 85 °C
< 95 % (non-condensing)
IP 20
Low resistance ground connection is a must for proper surge protection functioning.
Base element and connected protection module
220
www.hls-austria.com
Installation & Service
Installation Accessories
764733
OVP module for esserbus/esserbus-PLUS loop
1
1
Space-saving combined surge protector module for the protection of two wire pairs symmetrical ​
interfaces with electrical isolation.
Two overvoltage protection module of this type is required for each loop.
2
Technical Data
Rated voltage
Rated current
max. cont. operating voltage a.c.
max. cont. operating voltage d.c.
Nom. discharge current (80/20)/line
Total nom. discharge current
Total lightning imp. current (10/350)
Lightning imp. current (10/350)/line
Ambient temperature
Air humidity
Type of protection
48 V
1 A @ 45 °C
38.1 V AC
54 V DC
10000 A
20 kA
10 kA
2.5 kA
-40 °C ... 85 °C
< 95 % (non-condensing)
IP 20 (connected)
3
4
5
Accessories
764737 Base for overvoltage protection module
764734
OVP module
1
Space-saving combined surge protector module for the protection of one wire pair of symmetrical ​
interfaces with electrical isolation.
Technical Data
Rated voltage
Rated current
max. cont. operating voltage a.c.
max. cont. operating voltage d.c.
Nom. discharge current (80/20)/line
Total nom. discharge current
Total lightning imp. current (10/350)
Lightning imp. current (10/350)/line
Ambient temperature
Air humidity
Type of protection
6
7
8
180 V
0.75 A @ 45 °C
127 V AC
180 V DC
10000 A
20 kA
5 kA
2.5 kA
-40 °C ... 85 °C
< 95 % (non-condensing)
IP 20 (connected)
9
10
Accessories
764737 Base for overvoltage protection module
11
12
764736
OVP module for control outputs
1
Power-coordinated combined surge protector for the protection of ungrounded DC power supplies ​
for mounting-rail installation.
Protection of monitored and potential-free control outputs up to 36 volts.
Technical Data
Rated voltage
Rated current
max. cont. operating voltage d.c.
Nom. discharge current (80/20)/line
Total nom. discharge current
Total lightning imp. current (10/350)
Lightning imp. current (10/350)/line
Ambient temperature
Air humidity
Type of protection
13
36 V
7 A @ 40 °C
45 V DC
10000 A
20 kA
5 kA
2.5 kA
-40 °C ... 85 °C
< 95 % (non-condensing)
IP 20
14
No base support is required for the connection.
221
Installation & Service
Installation Accessories
764737
Base module for OVP modules
1
Base part as very space-saving, 4-pin, universal feed-through terminal to accommodate the surge ​
protector module without signal interruption.
The secure grounding of the surge protector module is established via the mounting rail support ​
base by means of a snap-on attachment.
As no components of the protection circuit are located in the base part, maintenance work is ​
restricted to the protection modules.
Technical Data
Ambient temperature
Air humidity
Type of protection
-40 °C ... 85 °C
< 95 % (non-condensing)
IP 20
Tool-free attachment on 35 mm mounting rails.
Junction Box Module
382040
8-fuse-card
1
Approval: VdS
Fuse card with 8 x 0.5 A fuses for individual power supply protection of each area, zone and ​
component. It can be used with all ESSER mains units, fire and intrusion detection panels.
Technical Data
Contact load
Connection terminal
Ambient temperature
Storage temperature
Air humidity
Weight
Dimensions
30 V DC / 1 A
0.6 mm to max. 1.5 mm²
-5 °C ... 50 °C
-25 °C ... 75 °C
< 95 % (non-condensing)
approx. 85 g
W: 65 mm H: 72 mm D: 15 mm
Possible installation in housings: Part No. 120240, 120242, 120244, 788600, 788601, ​
788650, 788650.10, 788651, 788651.10, 788603 and 788603.10
222
www.hls-austria.com
Installation & Service
Installation Accessories
1
Accessories
050510
Network interference suppression filter type 2VK3
1
The mains interference suppression filter is intended for later installation in all mains-operated ​
devices in which problems due to HF power failure arise.
Technical Data
Rated voltage
Rated current
Rated frequency
Ambient temperature
Dimensions
2
3
115 V-250 V AC
2A
50 ... 60 Hz
-10 °C ... 40 °C
W: 52.6 mm H: 46 mm D: 23.1 mm (without flange)
4
Mains interference suppression filter and terminal block
5
6
788602
Top-hat rail
1
Technical Data
Dimensions
7
L: 400 mm
Mounting kit
8
788652
Mounting rail for FACP
1
The top hat rail installation kit can be retrofitted into the IQ8Control and FlexES Control unit ​
housing. The hat rail is fitted to the mounting board via two screws. A maximum of two (Part No. ​
788603.10) module housings (option) can be mounted to the control unit housing.
Technical Data
Dimensions
9
10
L: 35 mm W: 175 mm (standard-snap-on mounting ​
rail)
11
Mounting rail and accessories
12
13
14
Application example
223
Installation & Service
Installation Accessories
788603.10
Module housing for top-hat mounting rail
1
For snap-on mounting rail of several electronic modules with 82 x 72 mm PCB size. Angled cable ​
entry.
Technical Data
Material
Color
plastic
green
1 x UM-profile and 2x side panels
Application example with transponder
788605
Mounting kit
1
Mounting kit required for mounting esserbus transponders in extension housings.
4 x spacer bolts and 2 x fixing screws
704147
Cable gland M12 with nut
1
Polyamide cable gland to increase the protection level.
Technical Data
Ambient temperature
Type of protection
Material
Color
Cable diameter
704148
Cable gland M16 with nut
1
Polyamide cable gland to increase the protection level.
Technical Data
Ambient temperature
Type of protection
Material
Color
Cable diameter
224
-20 °C ... 95 °C
IP 67
Polyamide
gray
3 mm
www.hls-austria.com
-20 °C ... 95 °C
IP 67
Polyamide
gray
8 mm
Installation & Service
Housings
1
Housings
788600
Housing surface mount, gray
1
Small distributor housing for esserbus transponders.
2
The following esserbus transponder types can be used:
- 2 esserbus transponders each of dimensions (W x H x D) 82 x 72 x 20 mm
- 1 esserbus transponder of dimensions (W x H x D) 150 x 82 x 20 mm
Technical Data
Type of protection
Material
Color
Dimensions
3
4
IP 40
ABS
gray, similar to RAL 7035
W: 189 mm H: 131 mm D: 47 mm
5
788601
Housing flush mount, gray
1
Same as 788600, but flush-mounted version.
6
Technical Data
Type of protection
Material
Color
Dimensions
7
788650.10
Housing surface mount, white
1
Same as 788600, but white.
Technical Data
Type of protection
Material
Color
Dimensions
IP 40
ABS
gray, similar to RAL 7035
W: 189 mm H: 131 mm D: 47 mm
W: 207 mm H: 149 mm (cover)
8
9
10
IP 40
ABS
white, similar to RAL 9003
W: 189 mm H: 131 mm D: 47 mm
11
12
788651.10
Housing flush mount, white
1
Same as 788601, but white.
Technical Data
Type of protection
Material
Color
Dimensions
13
IP 40
ABS
white, similar to RAL 9003
W: 189 mm H: 131 mm D: 47 mm
W: 207 mm H: 149 mm (cover)
14
225
Installation & Service
Housings
788655
IP55 base adapter for 788656
1
IP base adapter for extreme environmental conditions.
Technical Data
Type of protection
788656
IP55
High IP housing
1
Housing for esserbus transponder to increase IP rating in connection with 788655.
Technical Data
Type of protection
IP55
Housing + front cover
788655 base must be ordered separatelly for IP55 protection.
M200SMB
Surface mounting housing for one IQ8FCT XS module
1
Surface enclosure for one module with semi-transparent cover to see module label, address and
LED.
Technical Data
Dimensions
SMB6-V0
1
Surface mount housing for 6 IQ8FCT XS modules
Surface enclosure for 6 modules with semi-transparent cover to see module address and LEDs.
Technical Data
Dimensions
226
www.hls-austria.com
H: 143mm W: 130 mm D: 49 mm
H: 180 mm W: 245 mm D: 100 mm
1
2
3
4
5
6
7
8
9
10
11
Appendix
Planning Guide
Order Forms
228 12
229-234
Part Number Index
235-237
Index
238-245
13
14
227
Appendix
Planning Guide
Planning Guide for Loop Installation
This is a planning guide for loop-powered alarm devices.
The alarm current of each alarm device is defined as a load factor. When added up, the total load factor defines the
loop length and the maximum number of alarm devices.
The maximum load factor of all alarm devices may not exceed 96. Altogether up to 127 bus devices per loop can still
be connected. The "load factor" download file for easier load factor calculation is available within our customer section
at http://www.esser-system.com. The examples shown below refer to a wire diameter of 0.8 mm.
The Excel spread sheet for downloading contains as well the maximum powered loop length for wires with a cross
section of 1.0, 1.5, 2.5 mm².
Load factors:
Part No.
802382
802383
802384
802385
802386
807205
807206
807212
807213
807214
807322
807224
807332
807372
Type of alarm signaling device
Load factor
O/So optical smoke detector IQ8Quad with isolator.................................. 2
O2T/F multisensor fire detector IQ8Quad with isolator ............................. 2
O2T/So multisensor fire detector IQ8Quad with isolator ........................... 2
O2T/FSp multisensor fire detector IQ8Quad with isolator......................... 3
O2T/Sp multisensor fire detector IQ8Quad with isolator ........................... 3
IQ8Alarm/So signaler with isolator, white.................................................. 3
IQ8Alarm/So signaler with isolator, red .................................................... 3
IQ8Alarm/F signaler with isolator, amber flash.......................................... 3
IQ8Alarm/F signaler with isolator, blue/green/white flash ......................... 3
IQ8Alarm/F signaler with isolator, red flash............................................... 3
IQ8Alarm/Sp signaler with isolator, white.................................................. 3
IQ8Alarm/FSo signaler with isolator, red................................................... 3
IQ8Alarm/Sp signaler with isolator, red ..................................................... 3
IQ8Alarm/FSp signaler with isolator, red................................................... 3
Table 1.1: Maximum loop length depending on the total load factor
Maximum powered loop length
Total load factor
up to 700 m .................................................................................................................
91 up to 96
up to 800 m .................................................................................................................
85 up to 90
up to 900 m .................................................................................................................
79 up to 84
up to 1,000 m...............................................................................................................
73 up to 78
up to 1,100 m...............................................................................................................
67 up to 72
up to 1,300 m...............................................................................................................
61 up to 66
up to 1,500 m...............................................................................................................
55 up to 60
up to 1,700 m...............................................................................................................
49 up to 54
up to 2,000 m...............................................................................................................
43 up to 48
up to 2,500 m...............................................................................................................
37 up to 42
up to 3,000 m ..............................................................................................................
31 up to 36
up to 3,500 m...............................................................................................................
1 up to 30
Example 1:
How many IQ8Alarm alarm signaling devices with load factor 3.0 can be connected to one analog loop?
Max. total load factor 96 : 3.0 (load factor)= up to 32 pcs. IQ8Alarm devices can be connected
to each loop depending on the loop length (up to 700 m at a wire gauge 0.8 mm)
Example 2:
Various types of alarm signaling devices are connected to one loop:
Load factor
4 x 807205 alarm devices with load factor 3.0
= 4 x 3.0
27 x O2T/So multisensor fire detector IQ8Quad (802384) with load factor 2.0 = 27 x 2.0
= 12
+
= 54
total load factor = 66
As shown in table 1.1, the maximum loop length for a total load factor of 66 is 1,300 m (at a wire gauge 0.8 mm)
Example 3:
For alarm signaling with sounder, 25 x 802384 IQ8Quad O²T/So
detectors are installed - each in one office. What is the maximum loop length?
Load factor for one 802384 IQ8Quad O²T/So detector = 2 (load factor)
25 pcs. IQ8Quad O²T/So x 2 (load factor)
total load factor = 50
As shown in table 1.1, the maximum loop length is 1,700 m (at a wire gauge 0.8 mm)
228
www.hls-austria.com
Appendix
Order Forms
Order Information for Alarm Signaling Devices IQ8Quad and IQ8Alarm composed combination of other languages and customized version
1
1. The IQ8Quad O²T/FSp multisensor fire detector (Part No. 802385 ) and the IQ8Alarm "Combi" Speech Alarm
(Part No. 802385) can also be ordered with a different combination of languages.
2
The following five languages are the programmed standard for these speech alarms. The respective languages are
assigned with the five standard speech announcements for the IQ8Quad (Part No. 802385) and the IQ8Alarm
(Part No. 807372).
3
Country code
acc. to ISO
3166 -Alpha-2
Language
code acc.
to ISO 639-1 Evacuation 1
de
Germany
(DE)
en
Great Britain
(GB)
4
Evacuation 2
Alarm
Test message
Dies ist ein
Feueralarm. Bitte
verlassen Sie das
Gebäude umgehend über die
nächsten Fluchtwege. Die Feuerwehr ist alarmiert.
Achtung, Achtung!
Dies ist eine Gefahrenmeldung. Bitte
verlassen Sie das
Gebäude über die
nächsten
Ausgänge.
Achtung, im Gebäude ist eine
Gefahrensituation
gemeldet worden.
Bitte bleiben Sie
ruhig, und warten
Sie auf weitere
Anweisungen.
This is a fire alarm.
Please leave the
building immediately by the nearest
available exit.
Attention please.
This is an emergency. Please leave the
building by the
nearest available exit.
An incident has
been reported in the
building. Please
await further
instructions.
Ceci est une alarme
incendie,veuillez
évacuer
immédiatement les
locaux par la sortie
la plus proche.
Votre attention s'il
vous plaît, ceci est
une alarme. Veuillez
évacuer les locaux
par la sortie la plus
proche.
Un incident est
signalé dans le
batiment. Merci de
garder votre calme
et attendez les
prochaines
instructions.
Esto es una alarma
de incendio.
Abandonen
por favor el edificio
inmediatamente
por la salida de
evacuación
más cercana.
Atención. Esto es
una emergencia.
Por favor
abandonen el
edificio por la
salida de
evacuación
más cercana.
Atención, se ha
reportado un
incidente
en el edificio.
Aguarden por favor
otras instrucciones.
Esto es un
mensaje
de prueba.
No se requiere
ninguna acción.
La emergencia ha
sido cancelada.
Pedimos disculpas
por las molestias
causadas.
Attenzione.
Allarme incendio.
Abbandonare
l'edificio tramite
l'uscita di
emergenza più
vicina.
Attenzione.
Allarme in corso.
Vi preghiamo di
recarvi presso
l'uscita di
emergenza più
vicina.
Attenzione.
E' stato rilevato un
allarme.Ulteriori
disposizioni vi
verranno
comunicate
appena possibile.
Attenzione.
E' in corso una
prova di allarme.
Non è richiesta
alcuna azione.
Attenzione. Cessato
allarme.La situazione
di normalità è stata
ripristinata.
Dies ist eine
Testdurchsage.
This is a test
message.
No action is
required.
All-Clear
Die Gefahrensituation
ist jetzt behoben. Wir
entschuldigen uns
für jegliche
Unannehmlichkeiten.
5
6
The emergency is
now cancelled. We
apologize for any
inconvenience.
7
fr
France
(FR)
es
Spain
(ES)
it
Italy
(IT)
Ceci est un test.
L'alarme est à
présent annulée.
Veuillez nous excuser
pour le désagrément.
8
9
10
11
Standard speech messages of IQ8Quad detectors and IQ8Alarm
No.
Description
Frequency
1
School bell
complex
2
FP 1063.1 Telecoms
BS 5839 Pt1
Alternating 800 / 970 Hz at 2 Hz
Pulse rate
12
complex
f
0.25 sec.
0.25 sec.
t
0.5 sec.
3
BS 5839 Pt1
Alternating 800 / 970 Hz at 1 Hz
f
4
BS 5839 Pt1
Intermittent 970 Hz at 1 Hz 0.5 sec.
f
5
BS 5839 Pt1
Intermittent 2850 Hz at 1 Hz 0.5 sec.
f
6
BS 5839 Pt1
Intermittent 970 Hz 1/4 sec. ON - 1 sec. OFF
f
7
BS 5839 Pt1
Continuous 970 Hz
f
8
BS 5839 Pt1
Sweep tone 800 Hz tp 970 Hz at 7 Hz
f
9
BS 5839 Pt1
Sweep tone 800 Hz to 970 Hz at 1 Hz
f
10
DIN Tone
DIN 33404 Part 3
1200 - 500 Hz at 1 Hz
f
1.0 sec.
11
French fire sound
554 Hz / 100 ms + 440 Hz / 400 ms + 10 %
f
0.4 sec. 0.1 sec.
12
NL - Slow Whoop
500 Hz - 1200 Hz at 3.5 sec. break of 0.5 sec.
f
13
US - Horn
Continuous 485 Hz
f
14
US - Horn with
Temporal Pattern
Intermittent 485 Hz
(0.5 sec. ON; 0.5 sec. OFF; 3 times; 1.5 sec. OFF; Repeat)
f
15
US - March
Time
Alternating 485 Hz
(0.25 sec. ON; 0.25 sec. OFF; Repeat)
f
16
US - Slow
Whoop
Sweep tone 500 Hz to 1200 Hz
(4.0 sec. ON; 0.5 sec. OFF; Repeat)
f
17
US - Siren
f
18
US - Hi/Lo
Sweep tone 600 Hz to 1200 Hz
(1.0 sec. ON, Repeat)
Alternating 100 Hz / 800 Hz
(0.25 sec. ON; Alternate; 0.25 sec. ON; Alternate; Repeat)
19
US - NFPA
Whoop
IMO
GA-Signal
Sweep tone 422 Hz to 775 Hz
(upwards sweep 0.85 sec.; 3 times; 1 sec. OFF; Repeat)
Intermittent 800 Hz (1,0 sec. ON; 1,0 sec.
OFF: 7 times; 2.0 sec. ON: 2.0 sec. OFF; Repeat)
f
20
0.5 sec.
t
0.5 sec.
1.5 sec.
0.5 sec.
13
t
0.5 sec.
1.5 sec.
0.5 sec.
0.25 sec.
t
1.0 sec.
t
t
14
10 ms
t
1.0 sec.
t
t
t
3.5 sec.
0.5 sec.
t
t
0.5 sec.
1.5 sec.
0.5 sec.
t
0.25 sec.
0.25 sec.
t
4.0 sec. 0.5 sec.
t
1.0 sec.
t
f
0.25 sec.
0.25 sec.
0.85 sec.
t
1.0 sec.
t
f
1.0 sec.
1.0 sec.
t
IQ8Quad detectors and IQ8Alarm tone table
229
Appendix
Order Forms
Order Information: Composed Combination of Languages
Up to five languages can be provided per alarm signaling device.
Other combinations of languages can be ordered in accordance with the following order form.
The delivery time is approximately four weeks. Please note that returns or cancellations are not possible.
Order numbers for individual combination of languages
O²T/FSp multisensor fire detector IQ8Quad with isolator, composed version
IQ8Alarm/FSp signaler with isolator, red, composed version
IQ8Alarm/Sp signaler with isolator, white, composed version
IQ8Alarm/Sp signaler with isolator, red, composed version
O²T/Sp multisensor fire detector IQ8Quad with isolator, composed version
802385.SV98
807372.SV98
807322.SV98
807332.SV98
802386.SV98
Description:
Individual combination of languages
For example:
Phrase 1 Phrase 6 Phrase 11 Phrase 16 Phrase 21 -
802385.SV98
NL_nl
GB_en
DE_de
TR_tr
RU_ru
_____
5
10
15
20
25
NL_nl
GB_en
DE_de
TR_tr
RU_ru
The message type per language is always the
same as mentioned in the chart
"Additional languages for individual combination”:
1 Evacuation 1
2 Evacuation 2
3 Alarm
4 Test message
5 All-Clear
Order Information: Customized Combination of Language
In case you should need customized texts differing from the standard speech messages, additional signal tones or other
languages which are not listed in the order form, please contact international sales support.
Order numbers for customized programming of specific announcements/signals
O²T/FSp multisensor fire detector IQ8Quad with isolator, customized version
802385.SV99
IQ8Alarm/FSp signaler with isolator, red, customized version
807372.SV99
IQ8Alarm/Sp signaler with isolator, white, customized version
807322.SV99
IQ8Alarm/Sp signaler with isolator, red, customized version
807332.SV99
O²T/Sp multisensor fire detector IQ8Quad with isolator, customized version
802386.SV99
Description:
Customer specific announcements/signals
802385.SV99
NL_nl
GB_en
DE_de
TR_tr
RU_ru
Extra
For example:
Phrase 1 Phrase 6 Phrase 11 Phrase 16 Phrase 21 Phrase 26 -
5
10
15
20
25
31
NL_nl
GB_en
DE_de
TR_tr
RU_ru
Extra
(customer specific texts / special tones)
Information about delivery time and price of recording customized announcements and signals available upon request.
Please note that the maximum recording time is 169 seconds. Also please note that returns or cancellations are
not possible.
The programming of speech and/or tone data is carried out at the factory according to your specifications.
The programming of the customer data is carried out via the tools 8000 programming software.
Please take a look at the relevant instructions in the online help.
230
www.hls-austria.com
Appendix
Order Forms
Additional Languages for Individual Combination Page 1
Country code
acc. to ISO
3166 -Alpha-2
Language
code acc.
to ISO
639-1
1
Evacuation 1
Evacuation 2
Alarm
Test Message
All-Clear
2
SA
ar
---
3
Arabia
BA
bs
Ovo je požarni alarm Molimo da odmah napustite
zgradu koristeći najbliži
raspoloživi izlaz.
Pažnja. Ovo je
obavještenje o opasnosti.
Molimo napustite zgradu
koristeći najbliži raspoloživi
izlaz.
U zgradi se dogodio
incident.
Molimo sačekajte dalja
uputstva.
Ovo je poruka za
ispitivanje sistema.
Možete nastaviti sa vašim
akltivnostimo.
Opasnost je prestala.
Izvinjavamo se radi eventualnih neugodnosti.
pt
Atenção. Esta é uma
emergência. Por favor,
abandonem o edifício pela
saída de emergência mais
próxima.
Isto é um alarme de
incêndio. Abandonem por
favor, o edifício
imediatamente pela
saída de emergência mais
próxima
Atenção foi reportado um
incidente no edifício.
Aguardem, por favor,
outras instruções.
Esta é uma mensagem
de teste.
Não se requer nenhuma
ação.
A emergência foi cancelada.
Pedimos desculpas pelos
problemas causados
Bosnia
BR
Brasil
4
5
CN
6
zh
China Mandarin
7
DK
Brandalarmen er aktiveret
forlad venligst bygningen,
anvend nærmeste
nødudgang.
Dette er en nødsituation,
forlad bygningen brug de
opmærkede flugtveje.
Et varsel om brand bliver
undersøgt, afvent nærmer
besked.
fi
Huomio, kiinteistössä on
havaittu automaattinen
paloilmoitus. Poistu
rakennuksesta käyttäen
ohjattuja reittejä. Hissien
käyttö on kielletty.
Huomio, turvallisuussyistä
kiinteistöstä on poistuttava
välittömästi. Käytä ohjattuja reittejä.
Huomio, paloilmoitin on
ilmoittanut mahdollisesta
Paloilmoitinjärjestelmää
vaaratilanteesta.
Tutkimme asiaa ja annam- testataan.
me pian lisätietoja.
Palohälytys on ohi. Tilanne
on palautunut normaaliksi.
el
Αυτό είναι ένα μήνυμα
συναγερμού για πυρκαγιά.
Παρακαλώ εγκαταλείψτε το
κτίριο αμέσως από τις εξόδους
κινδύνου. Η πυροσβεστική
έχει δοποιηθεί.
Προσοχή, προσοχή!
Αυτό είναι ένα μήνυμα
για κατάσταση κινδύνου.
Παρακαλώ εγκαταλείψτε
το κτίριο από τις επόμενες
εξόδους.
Προσοχή στο κτίριο υπάρχει
κατάσταση κινδύνου.
Παρακαλώ παραμείνετε
ψύχραιμοι και περιμένετε
επόμενες οδηγίες.
Η κατάσταση κινδύνου έχει
αρθεί. Ζητούμε συγγνώμη
για τυχόν δυσάρεστες
καταστάσεις που
προκλήθηκαν.
ca
Aixó es una alarma
d´incendi.
Siusplau abandonin
l´edifici inmediatament per
la sortida d´evacuació més
propera.
Atenció. Aixó es una
emergencia.
Siusplau abandonin
l´edifici per la sortida
d´evacuació més propera.
Atenció. S´ha notificat un
incident a l´edifici.
Siusplau, esperin altres
instruccions.
Aixó es un missatge de
prova. No es requereix
cap acció.
hr
Ovo je pozarni alarm.
Molimo odmah napustite
objekt koristeci najblizi
izlaz za nuzdu. Vatrogasna
postaja je alarmirana.
Pozor! Pozor! Ovo je
priopcenje o neposrednoj
opasnosti. Molimo
odmah napustite objekt
koristeci najblizi izlaz za
nuzdu.
Pozor! U objektu je prijavljena opasnost. Molimo
ostanite mirni i pricekajte
daljnje upute.
Ovo je probno priopcenje.
Nikakve mjere nisu
neophodne.
Opasnost je prestala.
Ispricavamo se radi
eventualnih neugodnosti.
nl
Attentie,
er is een brandalarm.
Verlaat het gebouw via de
dichtstbijzijnde uitgang.
Attentie,
er is een calamiteit.
Verlaat het gebouw via de
dichtstbijzijnde uitgang.
Attentie,
er volgt een blussing,
verlaat de ruimte.
Dit is een testalarm,
dit is een testalarm.
Einde alarmmelding,
einde alarmmelding.
no
Brannalarmen er utløst,
forlat bygget, bruk de
oppmerkede
rømningsveiene.
Dette -er en nødsituasjon,
forlad bygget, bruk de
oppmerkede rømningsveiene.
Et automatisk varsel om
brann blir undersøkt,
avvent nærmere beskjed.
Dette er en testmelding,
ingen tiltak nødvendig.
Normaltilstand er
gjenopprettet, faren er
over.
da
Denmark
Fi
Finland
GR
Greece
ES
Catalonia
HR
Croatia
NL
Netherlands
NO
Norway
Dette er en test melding
ingen tiltag nødvendig.
Αυτή είναι μια δοκιμαστική
ανακοίνωση.
Normal tilstand er genoprettet, faren er overstået.
8
9
10
11
L´alarma ha estat
cancel.lada. Preguem
disculpin les molesties.
12
13
14
231
Appendix
Order Forms
Additional Languages for Individual Combination Page 2
Country code
acc. to ISO
3166 -Alpha-2
Language
code acc.
to ISO
639-1
PL
Evacuation 1
Evacuation 2
Stan alarmu został
odwołany. Przepraszamy
za wszelkie niedogodności
i utrudnienia.
Proszę o uwagę! To jest
komunikat alarmowy.
Proszę opuścić budynek
najbliższym dostępnym
wyjściem ewakuacyjnym.
Uwaga. W budynku
wystąpiło zdarzenie alarmowe. Proszę spokojnie
oczekiwać dalszych
instrukcji.
To jest komunikat testowy.
Nie są wymagane żadne
działania.
pt
Isto é um alarme de incêndio. Por favor abandonem
o edifício imediatamente
pela saída de evacuação
mais próxima.
Atenção. Isto é uma
emergência. Por favor
abandonem o edifício
pela saída de emergência
mais próxima.
Atenção, ocorreu um
incidente no edifício. Por
favor aguardem mais
instruções.
O alarme foi cancelado.
Atenção, isto é apenas um Queiram desculpar o
ensaio
inconveniente.
ro
Atenţiune, atenţiune! S-a
declanşat o alarmă de incendiu. Vă rugăm părăsiţi imediat
clădirea pe cea mai apropiată
cale de evacuare. Alarma a
fost transmisă la pompieri.
Atenţiune! Acesta este un
mesaj de
urgenţă. Vă rugăm părăsiţi
clădirea
pe cea mai apropiată cale
de ieşire.
Atenţiune. În clădire a fost
semnalat
un incident. Vă rugăm să vă
păstraţi
calmul şi să aşteptaţi noi
instrucţiuni.
Situaţia de urgenţă a luat
sfârşit. Ne cerem scuze
pentru eventualele
inconveniente.
sr
Ovo je požarni alarm!
Molimo vas da odmah
napustite zgradu koristeći
najbliži raspoloživi izlaz.
Pažnja! Ovo je
obaveštenje o opasnosti.
Molimo vas da naupustite
zgradu koristeći najbliži
raspoloživi izlaz.
U zgradi se desio incident.
Molimo vas da sečekate
dalja uputsva.
Ovo je poruka za ispitivan- Opasnost je prestala.
je sistema.
se zbog
Možete nastaviti sa vašim Izvinjavamo
eventualnih neugodnosti.
aktivnostima.
ru
Внимание. Пожарная
тревога. Пожалуйста
покиньте помещение
через ближайшие
аварийные выходы.
Внимание. Это
предупреждение о
пожарной опасности.
Пожалуйста покиньте
помещение через
ближайшие выходы.
Внимание. Поступило
предупреждение о
пожарной опасности.
Пожалуйста сохраняйте
спокойствие и ждите
дальнейшей информации.
Отмена пожарной
тревоги. Ситуация
Тестовое сообщение.
нормализовалась.
Идет проверка системы
Извините за причинённые пожарной сигнализации.
неудобства.
sv
Brandlarmet är utlöst, lämna omedelbart byggnaden
genom närmaste utgång.
Detta är en nödsituation,
lämna omedelbart byggnadengenom närmaste
utgång.
Larm om brand i byggna- Detta är ett testmeddeden blir undersökt, invänta lande, ingen åtgärd är
närmare besked.
nödvändig.
sk
Toto je požiarny poplach.
Opusťte prosim okamžite
budovu najbližším
núdzovým východom!
Pozor, hrozí
nebezpečenstvo.
Opusťte prosim budovu
najbližším núdzovým
východom!
V budove bola vyhlásená
pohotovosť. Počkajte
prosim na ďalšie pokyny.
Toto je testovacie hlásenie. Pohotovosť bola odvolaná.
Nie je potrebne naň
Ospravedlňujeme sa za
reagovať.
pripadne ťažkosti.
cs
Toto je požární poplach.
Prosím, opusťte okamžitě
budovu nejbližším únikovým východem.
Pozor, hrozí nebezpečí.
Prosím, opusťte budovu
nejbližším únikovým
východem.
V budově byla vyhlášena
pohotovost. Prosím,
vyčkejte dalších instrukcí.
Toto je testovací hlášení.
Není třeba na něj
reagovat.
Pohotovost je nyní
odvolána. Omlouváme se
za případné obtíže.
tr
Pohotovost je nyní
odvolána. Omlouváme se
za případné obtíže.
Acil bir durum var. Lütfen
binayı en yakın çıkış
noktasından terkedin.
Bu bir yangın uyarısıdır.
Bu bir yangın uyarısıdır.
Talimatlar için beklemede
kalın. Talimatlar için
beklemede kalın.
Yangın uyarısı test
edilmektedir. Bir şey
yapmanız gerekmiyor.
Bir şey yapmanız
gerekmiyor.
Tehlike geçmiştir. Tehlike
geçmiştir. Bir şey
yapmanız gerekmiyor.
hu
Tűzriadó! Kérem, azonnal
hagyják el az épületet az
Önökhöz legközelebb eső
kijáraton!
Figyelem! Vészhelyzet!
épületben váratlan
Kérem, azonnal hagyják el Az
esemény történt. További
az épületet az Önökhöz
legközelebb eső kijáraton! utasításig kérem várjanak!
Ez egy tesztüzenet.
Vészhelyzet törölve. Az
esetleges
kellemetlenségekért
elnézésüket kérjük.
Portugal
RO
Romania
RS
Serbia
Ru
Russia
Se
Sweden
SK
Slovakia
CZ
Czech Republic
TR
Turkey
HU
www.hls-austria.com
All-Clear
pl
PT
232
Test Message
Uwaga! Wystąpił alarm
pożarowy. Proszę
natychmiast opuścić
budynek najbliższym
dostępnym wyjściem
ewakuacyjnym.
Poland
Hungary
Alarm
Acesta este un mesaj de test.
Normalt tillstånd är återupprättat, faran är över.
ORDER FORM FOR IQ8 COMPOSED LANGUAGES
Honeywell Life Safety Austria GmbH
Customer
Data
Fax +43 1 600 6030-900
hls-austria@honeywell.com
1
2
Please fill out the following form for the registration of these data.
Company:
Customer ID:
Street:
Zip Code/City:
Contact Person:
E Mail:
Telephone:
Fax:
3
4
Order Number/Order Text:
Object:
Order
Combined
Version
___
802385.SV98
Quantity______
___
807372.SV98
Quantity______
___
807322.SV98
Quantity______
___
807332.SV98
Quantity______
___
802386.SV98
Quantity______
5
6
7
Languages
Choose
max. 5 languages
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
___
Repeat
Orders
or Additions
Country Code acc.
to Speech ISO 3166
Arabic
Bosnian
Catalan
Chinese Mandarin
Croatian
Czech
Danish
Dutch
English
Finnish
French
German
Greek
Hungarian
Italian
Norwegian
Polish
Portuguese
Portuguese/Brazil
Romanian
Russian
Serbian
Swedish
Slovak
Slovenian
Spanish
Turkish
For repeat orders or additions please
give the Order No. or the serial
number of the detector with special
languages.
Code acc. to ISO 639-1
8
ar
bs
ca
zh
hr
cs
da
nl
en
fi
fr
de
el
hu
it
no
pl
pt
pt
ro
ru
sr
sv
sk
sl
es
tr
SA
BA
ES
CN
HR
CZ
DK
NL
GB
FI
FR
DE
GR
HU
IT
NO
PL
PT
BR
RO
RU
RS
SE
SK
SL
ES
TR
9
10
11
12
13
14
Order Number:
Serial Number:
To be filled out by Honeywell Life Safety Austria GmbH:
Please forward to Novar GmbH when filled out!
Order number:
Date/Signature
Position:
233
ORDER FORM FOR IQ8 COMPOSED LANGUAGES
Honeywell Life Safety Austria GmbH
Customer
Data
Fax +43 1 600 6030-900
hls-austria@honeywell.com
Please fill out the following form for the registration of these data.
Company:
Customer ID:
Street:
Zip Code/City:
Contact Person:
E Mail:
Telephone:
Fax:
Order Number/Order Text:
Order
Combined
Version
___
802385.SV99
Quantity______
___
807372.SV99
Quantity______
___
807322.SV99
Quantity______
___
807332.SV99
Quantity______
___
802386.SV99
Quantity______
Technical Specifications
File with announcements/signals sent to
contact person in Neuss/Germany:
Sample should be approved by
(customer contact details):
Name:
Contact Person:
Telephone:
Address:
Email:
E Mail:
Address:
Remark:
Take note, these standards have to be followed:
•
max. length of all 5 announcements/signals is 25 seconds per file; one IQ8Quad or IQ8Alarm can record 169 seconds in total
Specifications for tone recording studio:
• WAVE or AIFF files mono with a sampling rate of 48kHz and a word width of 16-24bits
• Hi-pass: 220 Hz, 12 dB/oct.
• Lo-pass: 5 kHz, 12 dB/oct.
• Multi-band-compressor, 3-band
•
a. 25 Hz - 350 Hz. - 5,3 dB
b. 350 Hz - 5kHz. - 2,9 dB
c. 5 kHz - 18 kHz. - 6,4 dB
Brickwall-limiter
Info:
Depending on the sound quality we might have to pass it through an EQ, to make some modifications.
Additional costs for recording and/or fine tuning will be charged onetime per new file with a first order!
Second order with the same file without additional costs!
___
Repeat
Orders or
Additions
For repeat orders or additions please give
the Order No. or the serial number of the
detector with special languages.
Order Number:
Serial Number:
To be filled out by Honeywell Life Safety Austria GmbH:
Please forward to Novar GmbH when filled out!
Order number:
Position:
Date/Signature
234
www.hls-austria.com
Part Number Index
Part No.
Page
8100E172
013405.2046
01360150
01360350
01360451
01360551
01360652
01360752
01360851
01360950
01361049
01361152
01361252
01361353
01361649
01361749
01361852
01362453
01362553
01362650
01363149
01363557
01363657
01364350
01365053
01365253
01365354
01365554
01366151
01800134
01800234
01800434
01800634
01800734
01800934
01801134
045040207
050510223
06042689
06042790
06042995
06043195
382040222
701040104
704070105
704147224
Part No.
Page
704148224
704477.10103
704801.10102
704804102
704854102
704870102
70490099
70490199
70490299
70490399
70490499
704910104
704911105
704912105
704915104
704917105
704950111
704951111
704952111
704953111
704954111
704960115
704964115
704965
116, 135
704966116
704967
116, 143
704975115
704980112
704981
112, 134
704982112
704983112
73623520
74321220
74324520
74324821
74402721
74402821
74402921
74403021
761300170
761302170
761303170
761304170
761305170
761310171
761312167
Part No.
Page
761314167
761315164
761316164
761317165
761317.50165
761317.50.H167
761317.H166
761330171
761331171
761401.10166
761402.10166
761403166
761404.10168
761405.10168
761406168
761407168
761440167
761441167
761506181
761509181
761514181
761517181
761520.10182
761521.10182
761522.10182
761523.10183
761524.10183
761525.10183
761526.10184
761535186
761536186
761537.10186
761542.10184
761546.10186
761549184
761694117
761697121
764730220
764731220
764732220
764733221
764734221
764736221
764737222
76474480
76474580
Part No.
1
Page
76475281
76475481
76479036
765612217
765624217
766253207
767010214
767030216
767031216
767153215
767800206
767813.10218
767814.10218
76908095
769910106
769911106
76991420
76991521
769916106
769921104
77167019
77238646
77238746
77244520
77247618
77247718
77247818
77247918
78133532
78133633
78133733
781443154
781444155
781445156
781446156
781447156
781448156
781449156
78148287
78155088
781682106
781692106
781693107
781694107
781698107
781699107
2
3
4
5
6
7
8
9
10
11
12
13
14
235
Part Number Index
Part No.
Page
781814208
782302147
782306148
782307148
782308148
782310147
782311146
782315146
783312148
783313148
784382.D019
78438519
78471038
784710.CZ38
784710.PL38
784725.PL39
784743.CZ39
784743.PL39
78474440
78475340
78476644
784840.1043
784841.1043
78484219
78484343
78485544
78485645
78485945
78486543
78489220
78510137
78510737
78510937
78511337
78600017
78600216
78610017
78610216
78630217
78680217
78753119
78753219
788012.4025
788013.4025
788013.40.RU25
788014.4027
236
www.hls-austria.com
Part No.
Page
788014.40.CZ27
788014.40.GB27
788014.40.PL27
788014.40.RO27
78801628
788023.1028
78809317
78840028
78840128
78840228
78840428
78840628
788600225
788601225
788602223
788603.10224
788605224
78860646
788612133
788650.10225
788651.10225
788652223
78865328
78865428
788655226
788656226
78930011
78930111
78930212
78930315
789860.1022
78986122
789862.1023
78986323
78986424
78986624
796349218
80017161
80017761
80027161
800361.1063
80037162
80037462
80037562
801544.10175
801551187
Part No.
Page
801552187
801553187
801554187
801555187
801556187
801557187
801558187
801559187
801560187
801561187
801562187
801563187
801564187
801565188
801566188
801567188
801602185
801604175
801606185
801607185
801711174
801722174
801824208
80217165
80217765
80227166
80237166
80237366
80237467
80237567
802379155
80238273
80238373
80238473
80238574
802385.SV9874
802385.SV9974
80238675
802386.SV9875
802386.SV9975
80247368
803271.EX77
803371.EX77
803374.EX78
804382.D019
804473.10103
Part No.
Page
80474479
80479136
804868134
804870133
804900100
804901100
804902100
804905101
804906101
804920.EX120
804950113
804951113
804955114
804956114
804960.EX119
804961110
804970108
804971109
804973109
80555092
80555191
80555292
80555393
80556087
80557085
80557183
805572.5086
80557386
80557484
80557684
80557785
80558089
80558189
80558293
80558393
80558493
80558594
80558690
80558783
80558883
80558983
80559082
80559182
80559263
805593.10139
805594.10140
Part Number Index
Part No.
Page
805595.10141
80559734
805601.10142
805602.10143
805603143
805604144
805605144
80568332
806201206
806202206
807205199
807206199
807212204
807213204
807214RR205
807214WW205
807224202
807322200
807322.SV98200
807332201
807332.SV98201
807332.SV99201
807372203
807372.SV98203
807372.SV99203
80800310
80800415
80813910
80821915
808606128
808610.10129
808611.10130
808615130
808619.10131
808621127
808623125
808623.10126
808624133
808626133
808630.10132
808631.10132
85005488
85005588
950101182
950104182
950107183
Part No.
Page
950110183
950113184
950116183
950119182
960000.10.GB30
960001.10.GB30
960002.10.GB30
960003.10.GB31
960004.10.GB31
960005.10.GB31
960006.10.GB31
960007.10.GB31
960008.10.GB31
960110216
960119214
960120213
960121213
960122213
960124213
960126214
960127215
960128215
960129215
960130213
970120.IN157
970121.IN157
970123.IN157
970124.IN157
970125.IN157
970129.IN158
970130.IN158
970132.IN158
970133.IN158
970134.IN157
970135158
970137159
970138159
970139159
970140.IN162
970142.IN162
970143.IN162
970144.IN163
970146.IN163
970147.IN163
970148163
970150.IN160
Part No.
Page
970151160
970151.IN160
970153.IN160
970154160
970154.IN161
970161161
970165.IN161
970166158
970167158
BME2Z00224
CWR196
CWSO-RR-S1190
CWSO-WW-S1190
CWSS-RR-S3195
CWSS-RR-S5192
CWSS-RW-S5192
CWSS-WA-S7194
CWSS-WR-S3195
CWSS-WR-S5192
CWSS-WW-S5192
CWST-RA-S7193
CWST-RR-S5191
CWST-RW-S5191
CWST-WA-S7193
CWST-WR-S5191
CWST-WW-S5191
CWW196
DASA6-N152
F-A3384-000173
F-A-LC-A173
F-A-LC-E173
F-A-LC-G173
F-A-LC-H173
FL-IF-6
174
FS20X-211-23-6150
FS20X-211-24-6150
FS24X-911-23-6149
FS24X-911-24-6149
FSL100-IR3151
FSL100-SM21153
FSL100-TL153
FSL100-UV152
FSL100-UVIR152
FSX-A001152
M200SMB226
PS188196
Part No.
1
Page
PS189196
PS200122
PSU-12153
SC070122
SC076196
SH-001153
SM4 152
SMB6-V0
226
TL-1055153
TL-2055153
VEP-A00-1P180
VEP-A00-P180
VEP-A10-P180
VEU-A00179
VEU-A10179
VLC-500RO177
VLF-250177
VLF-500177
VLI-880178
VLI-885178
VLP-400176
VLS-600176
VSP-005181
VSP-962181
W1A-R1K0SG-E019-81
118
W1A-R1K0SG-U007-01
117
2
3
4
5
6
7
8
9
10
11
12
13
14
237
Index
Keyword
Page
3.6 V Lithium battery
34
3-way ball valve (ABS)
185
3-way ball valve (PVC)
185
4" trim ring and snap-in mounting clips for IQ8Quad
detector base
84
45° angle (ABS) for 25 mm pipe
183
45° angle (PVC) for 25 mm pipe
183
90° angle (ABS) for 25 mm pipe
182
90° angle (PVC) for 25 mm pipe
182
90° bend (ABS) for 25 mm pipe
182
90° bend (PVC) for 25 mm pipe
182
110/220VAC wallcharger test lamp
153
A
Acoustic alarm signaling device, red
Acoustic alarm signaling device, white
Adapter for pole 769813
Adapter module ADP-N3E
Adapter module ADP-PRS-422
Addressable MCP electronic module with zone
isolator, Series 9200
Addressable MCP, IP66
Adhesive, 0.5 kg can with brush-in-cap
Air filter for aspirating smoke detectors
Air shield assembly 6MM
Alarm and monitoring module for IQ8FCT XS,
IQ8FCT LP
Analog loop module
Analog loop module powered loop (PL)
Anchor plate DH50-AP-S
Anchor plate DH70-AP-S
Anchor setting tool
ASD FAAST LT EB, dual channel
ASD FAAST LT EB, single channel
ASD FAAST XM
Aspiration reducing film sheet, 2.0 mm
Aspiration reducing film sheet, 2.5 mm
Aspiration reducing film sheet, 3.0 mm
Aspiration reducing film sheet, 3.2 mm
Aspiration reducing film sheet, 3.4 mm
Aspiration reducing film sheet, 3.6 mm
Aspiration reducing film sheet, 3.8 mm
Aspiration reducing film sheet, 4.0 mm
Aspiration reducing film sheet, 4.2 mm
Aspiration reducing film sheet, 4.4 mm
Aspiration reducing film sheet, 4.6 mm
Aspiration reducing film sheet, 5.0 mm
238
www.hls-austria.com
190
190
89
40
40
103
117
186
175
152
133
19
19
216
216
163
174
174
172
187
187
187
187
187
187
187
187
187
187
187
187
Keyword
Aspiration reducing film sheet, 5.2 mm
Aspiration reducing film sheet, 5.6 mm
Aspiration reducing film sheet, 6.0 mm
Aspiration reducing film sheet, 6.8 mm
Aspiration reducing film sheet, 7.0 mm
Page
187
187
188
188
188
B
Base cover for IQ8Quad
Base deep IP 65, red
Base deep IP 65, white
Base module for OVP modules
Basic license for WINMAGplus USB port
Battery 12 V DC/1.2 Ah capacity
Battery 12 V DC/2.1 Ah capacity
Battery 12 V DC/7 Ah capacity
Battery 12 V DC/12 Ah capacity
Battery 12 V DC/17 Ah capacity
Battery 12V DC/24Ah capacity
Battery 12 V DC/38 Ah capacity
Battery extension housing
83
196
196
222
49
34
34
34
34
34
34
34
11
C
Cable gland for housing 764752
81
Cable gland M12 with nut
224
Cable gland M16 with nut
224
Carrying bag for test equipment
90
Ceiling holder for LRMX, for distances from 40 to 70
cm168
Ceiling holder for LRMX, for distances from 70 to
150 cm
168
Ceiling lead-through adapter (ABS)
184
Ceiling pendant mount for Fireray
167
CO capsule for multi-stimulus detector tester 805551
93
Combination signaling device EN 54-23 cat. W+C,
white flash
192
Combined acoustic/optical alarm device EN 54-3,
open class, red flash, red housing
195
Combined acoustic/optical alarm device EN 54-3,
open class, red flash, white housing
195
Combined acoustic/optical alarm device EN 54-23
cat. W+C, red flash, red housing
192
Combined acoustic/optical alarm device EN 54-23
cat. W+C, red flash, white housing
192
Combined acoustic/optical alarm device EN 54-23
cat. W+C, white flash, white housing
192
Index
Keyword
Page
Combined acoustic/optical alarm device, red flash,
white housing
194
Condensate trap for aspirating smoke detectors 185
Connection server developers kit
52
Control center software CD WINMAGplus basic kit49
Conventional MCP compact, small, red, glass pane
108
Conventional MCP electronic module
100, 113
Conventional MCP electronic module with 2nd microswitch100
Conventional MCP electronic module, with 2nd
micro-switch113
Conventional MCP electronic module with 2nd microswitch, Series 9000
103
Conventional MCP electronic module w/o snap-on
function100
CO test gas for smoke detector tester 805582
93
Cutting tool for FO steel sensor cable 970153.IN 161
D
Data points package
52
DC/DC converter 12 V/24 V DC
32
DC/DC converter output voltage 12 V DC
33
DC/DC converter output voltage 24 V DC
33
Detector base with relay contact for IQ8Quad
82
Detector base with relay output for ES Detect
800631.1063
Detector cover for IQ8Quad with built-in alarm
sounder83
Detector cover for IQ8Quad w/o built-in alarm
sounder83
Detector removal tool
89
Door magnet with distance pipe incl. flexible anchor,
400 N, 175 mm
213
Door magnet with distance pipe incl. flexible anchor,
400 N, 325 mm
213
Door magnet with distance pipe incl. flexible anchor,
400 N, 475 mm
213
Door magnet with release button incl. flexible anchor,
400 N
213
Door magnet w/o release button incl. flexible anchor,
400 N
213
Door magnet w/o release button incl. flexible anchor,
800 N
214
Door retainer DH50-N490-WM
214
Double head cable ties, 500 pcs
163
DTS evaluation unit warranty extention, 3 years 158
Keyword
1
Page
DTS evaluation unit warranty extention, 5 years 158
DTS interface box
158
Dummy cover 19", 2 HU
21
Dummy cover 19", 3 HU
21
Dummy cover 19", 5 HU
21
Dummy cover 19", 9 HU
21
2
3
4
E
E2000 APC 8° pigtail, 5 m
161
E2000 APC adapter to connect two connectors
970154.IN161
EMV isolator for IQ8Quad, ES Detect detector base
87
End cap (ABS) for 25 mm pipe
184
End cap (PVC) for 25 mm pipe
184
EOL-I terminating device
133
EOL-O terminating device
133
esserbus alarm transponder, 4 IN/2 OUT with isolator
125
esserbus communication transponder for ECP 8010
130
esserbus FSA transponder for fire doors
131
esserbus transponder 12 relays (8 bit)
129
esserbus transponder 32 LED
130
esserbus transponder for UniVario with isolator 126
esserbus transponder IQ8FCT LP
127, 128
esserbus transponder IQ8FCT XS
128
esserbus transponder RZT, 12 V
132
esserbus transponder RZT, 24 V
132
essernet® module, 62.5 kBd for IQ8Control
43
essernet® module, 500 kBd for IQ8Control
43
essernet repeater, 62.5 kBd
43
essernet repeater, 500 kBd
43
Ex barrier for intrinsic safe detectors Series IQ8Quad
Ex (i)
79
Ex barrier for intrinsic safe detectors Series IQ8Quad
Ex (i) and 9100
80
Ex door magnet, 1588 N
215
Ex manual call point IP67, small housing, red
118
Explosion-proof conventional MCP, IP66
121
Ex signaling device DS10, 12 V DC
207
Ex sounder, 12 V DC
207
Extension housing
15
Extension housing for batteries with 192 detector
zones11
Extension housing for SZI 192 detector zones
IQ8Control12
5
6
7
8
9
10
11
12
13
14
239
Index
Keyword
Page
Extension module with 1 additional micromodule slot
18
Extension module with 3 additional micromodule
slots18
Extention ATEX approval for Honeywell DTS detector
158
External power supply 2 A / 24 V DC 17Ah EN 54-4
30
External power supply 3 A / 24 V DC 17Ah EN54-430
External power supply 3 A / 24 V DC 28Ah EN 54-4
30
External power supply 5 A / 24 V DC 17Ah EN 54-4
31
External power supply 5 A / 24 V DC 28Ah EN 54-4
31
External power supply 5 A / 24 V DC 40Ah EN 54-4
31
External power supply 7 A / 24 V DC 17Ah EN 54-4
31
External power supply 7 A / 24 V DC 28Ah EN 54-4
31
External power supply 7 A / 24 V DC 40Ah EN 54-4
31
External power supply DCU 2403
32
Extinguishing control panel 8010 Series 4 with
operating unit, Czech
27
Extinguishing control panel 8010 Series 4 with
operating unit, Polish
27
Extinguishing control panel 8010 Series 4 with
operating unit, Romanian
27
Extinguishing control panel, Series 4, English
27
Extinguishing control panel, Series 4, German
27
Extinguishing panel 8010, Series 4, with operating
unit, German
25
Extinguishing panel 8010, Series 4, with operating
unit, Russian
25
Extinguishing panel 8010, Series 4, w/o operating
unit25
F
FACP IQ8Control C
10
FACP IQ8Control C for 19" rack
10
FACP IQ8Control M
15
FACP IQ8Control M for 19" rack
15
FACP remote SEI serial essernet interface
45
FB information and operating system, DIN A4, Polish
39
240
www.hls-austria.com
Keyword
Page
Field bus interface PLus
23
Filler panel front, neutral
17
Filter cartridge for air duct module 781443
155
Fire brigade operating panel, Czech
38
Fire brigade operating panel, German
38
Fire brigade operating panel, Polish
38
Fire department indicating panel FAT3000, Czech 39
Fire department indicating panel FAT3000, Polish 39
Fireray 50 RV with one prism
164
Fireray 100 RV with four prisms
164
Fireray 5000 detector head
166, 167
Fireray 5000, line smoke detector, incl. controller, 50
m165
Fireray 5000, line smoke detector, incl. controller,
100 m
165
Fixed heat detector ES Detect
61
Fixed heat detector ES Detect, Class B
61
Fixed heat detector IQ8Quad (class B), with higher
operating temperature with isolator
65
Fixed heat detector IQ8Quad with isolator
65
Flexible keeper plate for door magnets, Ø 55 mm216
Floor mounted bracket for door magnet 960119 and
960120215
Flush mount kit for base IQ8Quad
83
Flush mount release pushbutton for automatic door
release system, German
218
FO converter for essernet, single-mode
44
Foil for front face with universal text for large MCP
ABS, black lettering
105
FO sensor cable Safety FRNC
160
FO sensor cable Steel FRNC
160
Front foil with universal text for large MCP ABS,
white lettering
105
FS20X-211 IR/UV AL M25 FM/EN54
150
FS20X-211 IR/UV SS M25 FM/EN54
150
FS24X-911 3IR AL M25 FM/EN54
149
FS24X-911 3IR SS M25 FM/EN54
149
FSL100 Series Flame Detectors
151
FSL100 swivel mount
153
FSL100 test lamp, charger & case; non EX
153
FSX kit with Interface, RS485,USB cables
152
8-fuse-card222
G
Ground jumper for deep base
196
Index
Keyword
Page
H
Hardware option TCP/IP converter, Ethernet RS232 /
RS48546
Heat detector UniVario
147
Heat detector UniVario, 2 m
148
Heat detector UniVario, 6 m
148
Heat detector UniVario, 9 m
148
Heat detector UniVario, 200 mm
147
High dense I/O interface set for Honeywell DTS
detector159
High IP housing
226
Honeywell DTS Detector
157
Housing flush mount, gray
225
Housing flush mount, white
225
Housing for Ex barrier
81
Housing for SEI
46
Housing for small MCP, blue, similar to RAL 5015111
Housing for small MCP, green, similar to RAL 6002
111
Housing for small MCP, orange, similar to RAL 2011
111
Housing for small MCP, red, similar to RAL 3020 111
Housing for small MCP, yellow, similar to RAL 1021
111
Housing surface mount, gray
225
Housing surface mount, white
225
I
Indicating and operating panel for ECP 8010, Czech
28
Indicating and operating panel for ECP 8010, English
28
Indicating and operating panel for ECP 8010,
German28
Indicating and operating panel for ECP 8010, Polish
28
Indicating and operating panel for ECP 8010, Romanian28
Interface-Module RS232 / V24
46
Interface module TTY/CL 20 mA
46
IP43 damp room base adapter for IQ8Quad, ES
Detect detector base
86
IP43 protection for detector base IQ8Quad, deep
design86
IP43 protection for detector base IQ8Quad, flat
design85
Keyword
1
Page
IP54 kit for large MCP 7048xx
105
IP55 base adapter for 788656
226
IP55 kit for protective cover
107
IP66 housing for OSID image sensor (imager) 171
IP66 housing for OSID standard light source (emitter)
171
IQ8Alarm/F signaler with isolator, amber flash 204
IQ8Alarm/F signaler with isolator, blue/green/white
flash
204
IQ8Alarm/FSo signaler with isolator, red
202
IQ8Alarm/FSp signaler with isolator, red
203
IQ8Alarm/FSp signaler with isolator, red, composed
version203
IQ8Alarm/FSp signaler with isolator, red, customized
version203
IQ8Alarm IP 65 base, red
206
IQ8Alarm IP 65 base, white
206
IQ8Alarm/So signaler with isolator, red
199
IQ8Alarm/So signaler with isolator, white
199
IQ8Alarm/Sp signaler with isolator, red
201
IQ8Alarm/Sp signaler with isolator, red, composed
version201
IQ8Alarm/Sp signaler with isolator, red, customized
version201
IQ8Alarm/Sp signaler with isolator, white
200
IQ8Alarm/Sp signaler with isolator, white, composed
version200
IQ8MCP compact IP 66, small, red, with isolator
glass pane
110
IQ8MCP compact, small, red, with isolator and glass
pane109
IQ8MCP compact, small, red, with resettable
element109
IQ8MCP electronic module
114
IQ8MCP electronic module with isolator
101
IQ8MCP electronic module w/o isolator, with relay
101, 114
IQ8TAL with isolator, 1 contact IN/1 OUT
134
IQ8Wireless cover for wireless interface, red and
white144
IQ8Wireless detector base
139
IQ8Wireless gateway for devices
140
IQ8Wireless mounting frame for IQ8Quad detectors,
white144
IQ8Wireless mounting frames for IQ8Alarm, red and
white143
2
3
4
5
6
7
8
9
10
11
12
13
14
241
Index
Keyword
Page
IQ8Wireless transponder for devices, wall mount141
IQ8Wireless universal interface w/o cover, red 142
IQ8Wireless universal interface w/o cover, white 143
IR3 flame detector RED, ATEX FM EN54
151
Isolation and assembly block for safety Ex barrier 80
K
Kit for suspended installation
87
L
Label for release pushbutton
218
Label plate for detector base IQ8Quad
84
Language package Estonian, Latvian, Lithuanian,
Russian173
Language package German, French, Italian, Dutch
173
Language package Polish, Czech, Slovakian,
Hungarian173
Language package Slovenian, Croatian, Romanian,
Hungarian173
Large Conventional MCP Ex (i) IP 66/67, red with
glass pane
120
LCD indicator panel, Czech
37
LCD indicator panel, English
37
LCD indicator panel, Hungarian
37
LCD indicator panel, Polish
37
Lever lock - type 17 for key no. 801
20
Lever lock - type for key no. 901
21
Line heat detector Honeywell DTS - evaluation unit,
distance range 1 km
157
Line heat detector Honeywell DTS - evaluation unit,
distance range 2 km
157
Line heat detector Honeywell DTS - evaluation unit,
distance range 4 km
157
Line heat detector Honeywell DTS - evaluation unit,
distance range 6 km
157
Line heat detector Honeywell DTS - evaluation unit,
distance range 10 km
157
Loop isolator for transponder
133
Loop LED remote indicator panel for 32 messages36
M
Management software WINMAGPlus licence for
Honeywell DTS detector
51
Manual call point IP67, small housing, red
117
Master box interface module
19
Master box interface module, 8007/8008, ESSER 19
242
www.hls-austria.com
Keyword
Page
MCP housing ALU, large, glass pane
102
MCP housing ALU, large, neutral
102
MCP housing large with glass pane, blue, similar to
RAL 5015
99
MCP housing large with glass pane, green, similar to
RAL 6002
99
MCP housing large with glass pane, orange, similar
to RAL 2011
99
MCP housing large with glass pane, red, similar to
RAL 3020
99
MCP housing large with glass pane, yellow, similar to
RAL 1021
99
MCP housing with glass, print: house alarm
102
Metal key for large MCP
106
Micro splice-box IP20 for Honeywell DTS sensor
cables163
Modbus TCP/IP interface for Honeywell DTS
detector158
Module housing for top-hat mounting rail
224
Mounting adapter for intermediate ceilings
85
Mounting bracket for lintel installation
206
Mounting bracket for UniVario flame detectors 148
Mounting clip for 25 mm pipe
186
Mounting frame 19" IQ8Control C/M
20
Mounting frame for small MCP, red and white 116,
143
Mounting kit
224
Mounting plate for ceiling bracket for detector/single
reflector
168
Mounting rail for FACP
223
Mounting set for round and insulated air ducts 156
Mounting spider for ceiling bracket
168
Multiple-sector interface in housing
28
Multi-stimulus detector tester TF 1001
92
Multi-stimulus detector tester TF 2001
91
N
Network interference suppression filter type 2VK3
223
O
O2T/F multisensor IQ8Quad
73
O2T/FSp multisensor detector IQ8Quad, customized
version74
O2T/FSp multisensor detector IQ8Quad with composition of other languages
74
Index
Keyword
Page
O2T/FSp multisensor IQ8Quad
74
O2T multisensor detector ES Detect
62
O2T multisensor fire detector IQ8Quad Ex (i) w/o
isolator78
O2T multisensor fire detector IQ8Quad with isolator
67
O2T/So multisensor IQ8Quad
73
O2T/Sp multisensor IQ8Quad
75
O2T/Sp multisensor IQ8Quad, customized version75
O2T/Sp multisensor IQ8Quad, special language 75
Operating foil for large MCP 80490x, neutral
104
Operating front, English
16
Operating front for printer and w. take-up reel,
English17
Operating front with single zone indication 64,
English16
Operating front w. printer, w/o take-up reel - ESSER,
English17
Optical alarm signaling device, amber flash
193
Optical alarm signaling device, amber flash, red
housing193
Optical alarm signaling device EN 54-23 cat. W+C,
red flash, red housing
191
Optical alarm signaling device EN 54-23 cat. W+C,
red flash, white housing
191
Optical alarm signaling device, EN 54-23 cat. W+C,
white flash
191
Optical alarm signaling device, EN 54-23 cat. W+C,
white flash, red housing
191
Optical alarm signaling device IQ8Alarm EN 54-23
Kat. W, red flash
205
Optical alarm signaling device IQ8Alarm EN 54-23
Kat. W, white flash
205
Optical Smoke Detector Detect ES with relay
contact, 48 V DC operation
63
Optical smoke detector ES Detect
62
Optical smoke detector IQ8Quad Ex (i) w/o isolator
77
Optical smoke detector IQ8Quad with isolator
66
Option – ability for customized interface rights (clientside)53
Optional 2nd sensor channel for Honeywell DTS
detector158
Option – client
53
Option control group indication and alarm counter for
ECP 8010, German
28
Option – escalation
53
Keyword
1
Page
Option for 4 sensor channel for Honeywell DTS
detector158
Option IP55 shrink sleeve for large MCP 80490x105
Option - notification
53
Option – redundance
53
O-Ring for deep base
196
OSID Emitter standard power
170
OSID Emitter standard power, battery version 170
OSID Emitter, high power
170
OSID Imager - 7° coverage
170
OSID Imager - 80° coverage
170
OSID installation kit
171
O/So optical smoke detector IQ8Quad
73
OTblue-LKM multisensor fire detector IQ8Quad with
isolator155
OTblue multisensor detector ES Detect
62
OTblue multisensor fire detector IQ8Quad with
isolator67
OTG multisensor fire detector (CO) IQ8Quad with
isolator68
OT multisensor fire detector IQ8Quad with isolator66
"Out of order" sign, multilingual for 7047xx, 7048xx
and 70490x
104
OVP module
221
OVP module for control outputs
221
OVP module for esserbus/esserbus-PLUS loop 221
OVP module for essernet and RS485 interfaces 220
OVP module for TTY interfaces and conventional
zones220
OVP module including base support for 230 V power
supply line
220
2
3
4
5
6
7
8
9
10
11
12
13
P
14
Peripheral module
18
Peripheral module with 1 additional micromodule slot
18
Pipe (ABS), diameter 25 mm
182
Pipe cutter for PVC and ABS pipes
186
Pipe (PVC), diameter 25 mm
182
Plastic key for large MCP
106
Plastic spare key for small MCP
116
Plastic telescopic extension
89
Plastic telescopic rod
90
Plate for 1 prism
167
Plate for 4 prism
167
Power supply unit for automatic door release
systems, 12 V, 3 A
217
243
Index
Keyword
Page
Power supply unit for automatic door release
systems, 24 V, 1.5 A
217
Printer kit with paper take-up reel for IQ8Control C/M
20
Printer paper for printer 736234/784892
20
Programming cable for ECP 8010
24
Programming software tools 8000
22
Protective cage
88
Protective cover for manual call points, English 107
Protective cover for manual call points, German 107
Protective kit for MCP and TAL, transparent 116, 135
PVC detergent, 1l
186
R
19” rack mounting kit for SZI 192 detector zones 17
Rate-of-rise detector ES Detect
61
Rate-of-rise heat detector IQ8Quad Ex (i) w/o
isolator77
Rate-of-rise heat detector IQ8Quad with isolator 66
Reflector set for LRMX, for ranges of up to 80 m 166
Reflector set for LRMX, for ranges of up to 100 m166
3-relay common fault module
19
3-relay module
19
Relay controller set for Honeywell DTS detector 159
Relays extension set for Honeywell DTS detector159
Remote indicator esserbus-PLus for detector series
9200 and IQ8Quad, red
208
Remote indicator for Series 9000, 9200 and
IQ8Quad, red
208
Replacement air filter for FAAST XM
173
Replacement air filter pads for 801544.10
175
Replacement filter for 761509
181
Replacement integral filter for FAAST LT EB
174
Resettable element for small MCP
115
S
Seal for deep base
196
SEI serial essernet interface EDP, bidirectional
45
SEI serial essernet interface EDP, unidirectional 44
Sensor cable connectors for FO sensor cable
970150.IN160
Sensor cable connectors for FO sensor cable
970153.IN160
Sensor cable testing tool
160
Serial connecting cable for 789862.10
24
Service key for electronic module (Part No. 80490x)
106
244
www.hls-austria.com
Keyword
Page
Single reflector for LRMX
166
Sleeve (ABS) for 25 mm pipe
183
Sleeve (PVC) for 25 mm pipe
183
Small Conventional MCP Ex (i) IP 66/67, red with
glass pane
119
Smoke capsule for multi-stimulus detector tester
805550/5192
Smoke detector tester
93
Smoke pellets for testing purposes
95
Smokesabre test gas for smoke detectors
94
Spare battery baton
95
Spare glass pane for MCP housing 70490x, 7048xx
und 761694
104
Spare glass pane for small MCP, EN54
115
Spare glass pane for small MCP, EN54, neutral 115
Spare glass pane red for MCP housings 7047xx and
7048xx104
Spare key 1D009 for FACP
20
Spare key 801 for FACP
20
Spare key 901 for FACP
21
Spare keys pack for MCP
122
Special painting IQ8Quad
88
Special painting IQ8Quad detector base
88
Splice-box IP67 for Honeywell DTS sensor cables
163
Stainless steel anchor with plastic clamp for
Honeywell DTS cable
162
Standard base UniVario
148
Standard detector base for IQ8Quad
82
Standard LED remote indicator panel
36
Starter kit equipment PLus with programming software tools 8000
22
Steel anchor with plastic clamp for Honeywell DTS
cables162
Steel anchor with steel clamp for Honeywell DTS
cables162
Suctions hose set for 25 mm pipe
184
Sun shield SS SS2/SS4/FS24X
153
Surface mount housing for 6 IQ8FCT XS module226
Surface mount housing for small MCP and TAL, blue,
similar to RAL 5015
134
Surface mount housing for small MCP, blue, similar
to RAL 5015
112
Surface mount housing for small MCP, gray, similar
to RAL 7035
112
Surface mount housing for small MCP, orange,
similar to RAL 2011
112
Index
Keyword
Page
Surface mount housing for small MCP, red, similar to
RAL 3020
112
Surface mount housing for small MCP, yellow, similar
to RAL 1021
112
Surface moun. housing for 1 IQ8FCT XS module226
Surface mount release pushbutton for automatic
door release system, German
218
Surface spacer for protective cover
107
Switched-mode power supply with cylindrical plug 24
Swivel mount
152
SZI front for 192 detector zones
17
T
Terminal card for panel 8010 in 19" rack, 1 m
28
Terminal card for panel 8010 in 19" rack, 2 m
28
Test gas for smoke detector tester 805582
93
Test head for heat detector w.battery and charger 95
Test lamp FS18X/FS20X/FS24X EXP
153
Test lamp FS18X/FS20X/FS24X NON-EXP
153
Three-channel infrared flame detector UniVario 146
Top-hat rail
223
T-Piece (ABS) for 25 mm pipe
183
T-Piece (PVC) for 25 mm pipe
183
Transparent cover for MCP
122
U
Univ. bracket for F5000 or prism plate
761440/761441167
USB cable A/B for 789862.10 field bus and panel
interface23
UV flame detector RED, ATEX FM EN54
152
UV flame detector UniVario
146
UVIR flame detector RED, ATEX FM EN54
152
UVIR flame detector RED, ATEX FM EN54
152
V
Venturi air duct module for IQ8Quad OTblue-LKM
(802379)154
Venturi tube for IQ8Quad air duct construction set
781443, 0.6 m
156
Venturi tube for IQ8Quad air duct construction set
781443, 1.5 m
156
Venturi tube for IQ8Quad air duct construction set
781443, 2.8 m
156
VESDA 300 PC interface
181
VESDA filter for VEU, VEP
181
VESDA filter for VLP, VLS, VLF, VLC
181
VESDAnet™ connection box
181
Keyword
VESDA VEP 1 pipe with LEDs
VESDA VEP 4 pipe with display
VESDA VEP 4 pipe with LEDs
VESDA VEU with Display
VESDA VEU with LEDs
VESDA VLC
VESDA VLF-250
VESDA VLF-500
VESDA VLI Relay only
VESDA VLI with VesdaNet
VESDA VLP
VESDA VLS
1
Page
180
180
180
179
179
177
177
177
178
178
176
176
2
3
4
5
6
W
Wall and floor swivel bracket for door magnet 960119
and 960120, angled, 150 mm
215
Wall and floor swivel bracket for door magnet 960119
and 960120, angled, 300 mm
215
110/220VAC wallcharger test lamp
153
Wall mounted door magnet w/o release button, 490
N214
Wall mount housing IP66 for Honeywell DTS
157
Weather protection housing for air duct construction
set 781443
156
Weather protective cover for MCP housings
7047/48xx, blue
106
Weather protective cover for MCP housings
7047/48xx, red
106
WINMAG installation upgrade as of version 6
49
WINMAGLite upgrade to WINMAGplus full version57
WINMAGLite with USB dongle
57
WINMAGplus – 4-monitor support option
54
WINMAGplus – AutoCAD option
54
WINMAGplus control center software - subsequent
upgrade50
WINMAGplus license - access control
50
WINMAGplus license connection server
52
WINMAGplus license - fire detection technology 50
WINMAGplus license - Galaxy Dimension
50
WINMAGplus license - intrusion detection technology50
WINMAGplus license – OPC client
52
WINMAGplus license – OPC server
52
WINMAGplus license - rescue route technology/
escape door control
51
WINMAGplus license - RTD
51
WINMAGplus license - video technology
51
WINMAG upgrade to WINMAGplus
49
7
8
9
10
11
12
13
14
245
Honeywell Life Safety Austria GmbH
Technologiestrasse 5, Building F, 3rd floor
1120 Vienna, Austria
Phone: +43 1 600 6030
Fax:
+43 1 600 6030-900
www.hls-austria.com
hls-austria@honeywell.com
Part No. 054581.AT.G0
June 2017
Subject to change without notice
©2017 Honeywell International Inc.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising