colony® pro installation instructions

colony® pro installation instructions
COLONY® PRO
INSTALLATION
INSTRUCTIONS
7075.100
7075.102
7075.104
SINGLE LEVER MONOBLOCK
LAVATORY FAUCET
Thank you for selecting American Standard...
the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly-please read
these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1M
RECOMMENDED TOOLS
Screwdriver
1 INSTALL FAUCET CAUTION
Channel Locks
Adjustable Wrench
Tubing Cutter
Turn off hot and cold water
supplies before begining.
• Seat SEAL (2) into under side of FAUCET BODY (1).
• Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN ASSEMBLY
(8) through the mounting hole of lavatory. Figure A.
• From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6), pulling
faucet to front of sink, so SUPPLIES (3) rests against mounting hole.
Before final tightening, make sure collar on MOUNTING NUT (6) is
seated into RETAINING WASHER (5).
Figure A
(OPTIONAL
DECK PLATE)
2000102P-YYY
• Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)
to complete faucet mounting.
1
4
2
MOUNTING
SURFACE
3
5
8
7
5
COLLAR ON
MOUNTING NUT
6
4
Figure B
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2016
-1-
M965764 (8/16)
2 INSTALL POP-UP DRAIN
2a
• Push TAIL PIECE (11) down into TRAP (C) (threaded end up).
1
• Thread LOCKNUT (5), WASHER (4) and GASKET (3)
(Bevel side up) onto DRAIN BODY (10).
2
• Apply a bead of PUTTY (D) to underside of FLANGE (2).
A
• Feed DRAIN BODY (10) up through SINK (A) and thread
the FLANGE (2) fully onto DRAIN BODY (10).
D
• Tighten LOCKNUT (5) firmly, keeping the pivot rod hole pointed
towards the back of the sink.
3
6
4
7
• Assemble PIVOT ROD (9) as shown in Figure-2a.
Notice the position of the CONCAVE WASHER (G).
5
• Insert PIVOT ROD (9) into DRAIN BODY (10) and tighten
PIVOT NUT (F).
10
• Pull TAIL PIECE (11) up and thread tightly into
DRAIN BODY (10).
11
G
E
F
8
F
C
1-1/4"
• Position EXTENSION ROD (7) onto POP-UP ROD (E) and tighten
THUMBSCREW (6).
9
• Remove one end of CLIP (8) from PIVOT ROD (9) by squeezing ENDS TOGETHER WHILE SLIDING.
• Insert PIVOT ROD (9) into second or third hole in EXTENSION ROD (7) and reassemble CLIP (8).
• DROP STOPPER (1) into DRAIN BODY (10).
• Adjust stopper height by repositioning EXTENSION ROD (7) and tightening THUMBSCREW (6).
3 CHECK OPERATION OF POP-UP
• Operate LIFT KNOB (1) to verify that
STOPPER (2) opens and closes.
1
2
4 MAKE WATER SUPPLY AND WASTE CONNECTIONS
• Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression.
Connect left SUPPLY (1) to Hot (Marked with a Red Band)
and right supply to COLD (2) wall supply.
• Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
APPROX. 20"
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
2
1
RED
BAND
BLUE
BAND
3/8" COMPRESSION
HOT
-2-
COLD
M965764 (8/16)
5 TEST INSTALLED FITTING
ON
OFF
1
• With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
COLD
HOT
• Remove AERATOR (3).
• Operate HANDLE (1) to flush water lines thoroughly.
3
• Replace AERATOR (3).
4
CHECK DRAIN CONNECTIONS
• Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in Sink.
• Release POP-UP KNOB (4) down and check all drain
connections and “P” trap for leaks.
Tighten
if necessary.
WASTE
OUTLET
2
2
6 SERVICE
CAUTION
“P” TRAP
Turn off hot and cold water
supplies before beginning.
• To remove or replace cartridge:
– Turn valve to OFF position.
– Pull out PLUG BUTTON (1) and remove HANDLE SCREW (2).
– Pull off HANDLE (3) and CAP (4).
– Pull out CARTRIDGE (5).
– Inspect CARTRIDGE (5) and O-RINGS (6) for debris and
clean if necessary.
– Clean MANIFOLD (7) and rinse clean.
– Reinstall CARTRIDGE (5) and O-RINGS (6) onto
MANIFOLD (7).
– Reinstall CAP (4) and HANDLE ASSEMBLY (3).
• If spout drips, operate handle several times from OFF to ON
and HOT to COLD position. Do not force - handle turns only 90˚.
ADJUST HOT LIMIT SAFETY STOP
By restricting HANDLE rotation and limiting the amount of
hot water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP (8) reduces risk of accidental scalding. To lower the
maximum hot water temperature of your faucet, all you need to
do is adjust the setting on the HOT LIMIT SAFETY STOP (8).
Note: The HOT LIMIT SAFETY STOP (98 is set at the neutral
setting from the factory. Fig. A.
2.5mm HEX KEY
1
3
2
8
COLDER
9
4
A
+HOTTER
9
SETTING
MARKS
10
8
B
5
6
7
• To adjust HOT LIMIT SAFETY STOP:
– Remove HANDLE ASSEMBLY (3), CAP (4)
– Set the CARTRIDGE STEM (9) to the OFF position.
– Lift up the HOT LIMIT SAFETY STOP 8).
– Place the HOT LIMIT SAFETY STOP (8) in the desired GRAY
SHADED AREA (10) to limit the hot water. Fig. B.
– Reinstall CAP (4) and HANDLE ASSEMBLY (3).
7 CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
-3-
M965764 (8/16)
COLONY® PRO
SINGLE LEVER
MONOBLOCK
LAVATORY FAUCET
M970184-YYY0A
HANDLE KIT
MODEL NUMBERS
M970194-YYY0A
SET SCREW & BUTTON
& INDEX BUTTON RED/BLUE
M907315-YYY0A
CARTRIDGE CAP
7075.100
7075.102
7075.104
Replace the “YYY” with
appropriate finish code
M918511-0070A
CARTRIDGE SCREWS
POLISHED CHROME
002
LEGACY BRONZE
278
SATIN NICKEL
295
M951483-0070A
CARTRIDGE
M970185-YYY0A
POP-UP ROD
M964479-0070A
AERATOR (1.2 GPM)
(OPTIONAL DECK PLATE)
2000102P-YYY
M962090-0070A
MOUNTING KIT
M953465-YYY0A
PLASTIC DRAIN ASSEMBLY
M953450-YYY0A
METAL DRAIN ASSEMBLY
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST
Saturday 10:00 a.m. to 4:00 p.m. EST
IN CANADA 1-800-387-0369
(TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
-4-
M965764 (8/16)