ATC-1400A Transponder/DME Test Set
The ATC-1400A is a microprocessor-based test set designed to accomplish comprehensive testing
of modern ATC transponder and DME equipment
•
Continuous display of UUT, PRF, % reply
and transmitter frequency and power
SIGNAL GENERATOR
•
Variable SLS and Echo Pulse Level
•
Digital display of decoded transponder
reply pulses
User selectable L-Band Output Frequency can be selected by direct
MHz, VOR paired and TACAN channel designation.
•
Acceleration, velocity and range DME
Modes
•
TACAN modulation and reference bursts
•
Two-year limited warranty
Frequency Select Modes
∆F Capability
The selected frequency can be varied ±9.99 MHz in 0.01 MHz
increments.
Manual/Automatic Stepping
The selected frequency can be automatically varied in 1 MHz increments.
Aeroflex is a leader in the design, manufacture
and marketing of Avionics test systems.
Suppressor ON/OFF
The ATC-1400A is a microprocessor-controlled
test set designed to accomplish complete testing of modern ATC Transponder and DME
equipment.
DME MODE
The suppressor pulse output may be switched ON or OFF and the
level adjusted from the front panel.
Range Delay
Switch selectable -1.00 to 399.90 NMi
Velocity
Select inbound or outbound. Inbound and outbound velocity decrements range to 0 NM, then increments range 9990 KTS.
Acceleration
Non-zero acceleration decrements the selected velocity to 0 KTS,
then increments velocity to 9990 KTS.
Squitter
Digitally implemented to provide stable rate distribution and
repeatability
For the very latest specifications visit
www.aeroflex.com
atc1400aiss3.qxd
02/Dec/2004
10:23
Page 2
TACAN Simulation
Transmitter Frequency Discriminator
When TACAN/On is selected, output pulses are AM modulated with
15 and 135 Hz signals.
View frequency variation within the measured pulse
Echo Pulses
Transmitter power of P1 or P2 in DME Mode and/or F1 or F2 in XPDR
Mode may be selected and displayed on the front panel.
Front panel selectable
Ident Pulses
Select continuous pulse or Morse code from front panel
Transmitter Power Meter
Added Features
• IEEE-488-1978 GPIB
•
Automatic frequency stepping
•
TACAN Channel: VOR pairing, or direct UHF frequency
selection
•
The serial BCD distance word is generated to correspond to the
range distance programmed in the test set. This serial BCD word is
available at the back panel through a 25 pin D type connector.
Variable interference and double interrogation pulse position
•
DME serial data output
•
DME serial data input
Frequency Channelling
•
2-out-of-5 code frequency channeling outputs
The 2-out-of-5 VOR Paired Channel Frequency is available for control of the DME UUT when the test set is in the automatic frequency stepping mode.
ATC-1400A
Pulse Characteristics
DME Pulses are formed by filtering, which provides superior representation of Gaussian shaped pulses.
DME Serial Data Interface
ARINC 568 compatible
Transponder Mode
Modes 1, 2, T, A, B, C, D, AC1 and AC2 are available.
Variable Pulse Spacing
P2 and P3 pulse spacing may be varied in the “+” or “-” direction or
may be selected to the calibrated spacing from individual switches on
the front panel.
Accessory Units
When interfaced with the T-1401, I-1402, S-1403DL/MLD or
SI-1404 accessory units, the ATC-1400A becomes a comprehensive
test system for TACAN, Mode 4 XPDR/RADAR and Mode S XPDR
avionics equipment. For more information see separate data sheets.
Non-Coherent SLS Option
P2 provided on separate 200 MHz carrier, phase unsynchronized.
(Factory or factory service center installed option.)
SPECIFICATIONS
Pulse Width
The generated pulse width may be varied or selected for a calibrated
width by a front panel switch.
Side Lobe Suppression
On/Off selectable P2 pulse
Interference/DBL Interrogation
The Interference pulse and double interrogation functions are combined in a single switch and are exclusively selectable.
UUT Pulse Spacing Detector
SIGNAL GENERATOR CHARACTERISTICS
Range
952.01 to 1222.99 MHz, selectable in 0.01 MHz increments
Accuracy
±0.001%
∆F
±9.99 MHz in 0.01 MHz increments from the selected frequency
OUTPUT CHARACTERISTICS
Transponder reply pulses are verified for proper position by selection
of a narrow window. A wide window is provided when pulse position
accuracy verification is not desired.
Range
Suppression Recovery
Overall Accuacy
Selection of double interrogation and suppressor pulse provides a single interrogation after suppressor pulse spacing may be varied by
interference/DBL interrogation switch.
UUT MEASUREMENTS
Transmitter Frequency Counter
The average frequency of one pulse in a reply (XPDR Mode) or an
interrogation (DME Mode) is counted and continuously displayed.
In the DME Mode either P1 or P2 may be selected to be counted. In
XPDR Mode the F1 or F2 may be counted.
0 to -127 dBm (into 50 Ω) in 1 dB increments
±2.0 dB 0 to -90 dBm
±2.5 dB -90 to -110 dBm
Frequency Flatness
±0.6 dB Maximum
ON/OFF Ratio
80 dB minimum
Output Impedance
50 Ω, VSWR < 1.2:1
atc1400aiss3.qxd
02/Dec/2004
10:23
Page 3
Residual FM
TACAN SIMUALATION CHARACTERISTICS
(INTERNATIONAL)
5 kHz peak to peak maximum
AM Modulation Frequencies
Phase Noise
15 and 135 Hz ±0.02%
> 90 dBc/Hz measured at 150 kHz from the carrier
AM Modulation %
Spurious
21% (±3%) each component
>60 dBc from 350 to 1800 MHz
Bearing Output
SUPPRESSOR PULSE OUTPUT CHARACTERISTICS
180° (approx)
Pulse Width
ECHO PULSE CHARACTERISTICS
33 µs (±3 µs)
Position
Amplitude
30 NM (±1 NM) after the interrogation is received in X channel
Adjustable from 3 to 27 V
Amplitude
Timing
-19 to +6 dB, referring to the desired reply, selectable in 1 dB increments
DME function nominally 3.5 µs prior to P1 of range reply
XPDR Function
Accuracy
0.8 µs prior to P3
±0.2 dB (0 to -10 dB)
±0.5 dB (-11 to -19 dB)
DME MODE CHARACTERISTICS
REPLY EFFICIENCY CHARACTERISTICS
RANGE DELAY
Range
Range
0 to 399.99 NM selectable in 0.01 NM increments. -1 NM selected
by individual switch
0% to 100% selectable in 10% increments (1% under GPIB control)
Accuracy
±1.0% of interrogations 0% and 100%
±5.0% of interrogations 10% and 90% Typical
Accuracy
±0.02 NM plus ±0.005% of selected range
PULSE CHARACTERISTICS
VELOCITY
Range
Spacing
0 to 9990 KT selectable in 10 KT increments
12 µs ±0.1 µs (X channel), P1 to P2, 50% pk
Accuracy
30 µs ±0.1 µs (X channel), P1 to P2, 50% pk
±0.05%
P2 Deviation
ACCELERATION
±7.9 µs in 0.1 µs increments (X and Y Channel)
Range
Note: in X channel, P1 and P2 merge when P2 is deviated greater than
-5.0 µs
0 to 399 ft/sec2 selectable in 1 ft/sec2 increments
Accuracy
Rise Time
±0.5 ft/sec2
2.0 µs (±0.25 µs) (10% to 90%)
SQUITTER
Fall Time
Range
2.5 µs (±0.25 µs) (90% to 10%)
Selectable from 10 to 5999 Hz in 1 Hz increments (Ave. squitter)
Accuracy
Width
3.5 µs (±0.5 µs) (50% to 50%)
±2%
Spectrum
Distribution
>55 dB down from center frequency measured at ±800 kHz
At 2700 Hz the distribution is in compliance with the requirements presented in ARINC characteristics 568
R-NAV CHARACTERISTICS
Spacing
50 µs (±0.25 µs) at 0 NM (X Channel) 56 µs (±0.25 µs) at 0 NM (Y
Channel)
P1 at time of interrogation
P2 at time of reply
For the very latest specifications visit
www.aeroflex.com
atc1400aiss3.qxd
02/Dec/2004
10:23
Page 4
Width
7 µs (±1 µs)
IDENT PULSE CHARACTERISTICS
Rate
1350 Hz (±0.02%)
EQUALIZER PULSED CHARACTERISTICS
100 µs after ident pulse
DOUBLE INTERROGATION CHARACTERISTICS
Range
Measured from P1 first interrogation to P1 second interrogation, selectable to 0.1 µs increments
Accuracy
±5 ns plus 0.05%
UUT PULSE SPACING DETECTOR
Window Width
TRANSPONDER MODE CHARACTERISTICS
INTERROGATION RANGE
Range
10 to 7999 Hz selectable in 1 Hz increments
Accuracy
±0.005%
PULSE CHARACTERISTICS
Mode Spacing
3.0 µs (±5 ns) (Mode 1)
5.0 µs (±5 ns) (Mode 2)
6.5 µs (±5 ns) (Mode T)
8.0 µs (±5 ns) (Mode 3/A)
17.0 µs (±5 ns) (Mode B)
21.0 µs (±5 ns) (Mode 1)
25.0 µs (±5 ns) (Mode 1)
Variable Pulse Spacing
±1.85 µs selectable in 0.05 µs increments for P1 to P2, P1 to P2 independently variable in direction relative to P1
Width
0.8 µs (±5 ns) (CAL switch position)
0.20 to 1.85 µs selectable in 0.05 µs increments (VAR Switch
Position)
Rise Time
70 ns (+10 ns, -20 ns) (10% to 90%)
Fall Time
70 ns (+10 ns, -20 ns) (90% to 10%)
SIDE LOBE SUPPRESSION (SLS)
Amplitude
-19 to +6 dB, relative to P1, selectable in 1 dB increments
Accuracy
±0.2 dB for -10 to +3 dB
INTERFERENCE PULSE CHARACTERISTICS
Position Range
-17.5 to +399.0 µs referenced to P1, selectable in 0.1 µs increments
Accuracy
±0.05 µs
Width
Continuously adjustable from 0.2 to 5 µs by front panel control
Narrow: 220 ns nominal, referenced to P1
Wide: 750 ns nominal, referenced to P1
UUT MEASUREMENT CHARACTERISTICS
TRANSMITTER FREQUENCY COUNTER CHARACTERISTICS
Range
1020 to 1155 MHz
Accuracy
±20 kHz (DME Mode)
±50 kHz (XPDR Mode)
TRANSMITTER FREQUENCY DISCRIMINATOR OUTPUT
Response
1 MHz/V ±10% into open load
2 MHz/V ±10% into a 50 Ω load
Bandwidth
10 MHz minimum
TRANSMITTER POWER METER CHARACTERISTICS
Frequency Range
1020 to 1155 MHz
Amplitude Range
0 to 3999 W pk
Accuracy
±0.5 dB (from 50 Ω source) 100 to 3999 W
±0.7 dB (from 50 Ω source) 1 to 99 W
GENERAL
Power
Source Voltage and Frequency
100 to 120 VAC, 60 Hz
220 to 240 VAC, 50 Hz.
Power Consumption
120 W maximum
94 W nominal at 115 VAC
86 W nominal at 230 VAC
Nominal Input Current
1.49 A at 115 VAC
0.88 A at 230 VAC
Electromagnetic Compatibility
Complies with the limits specified in the following standards:
EN 55011:1991 Class B
EN 50082-1
atc1400aiss3.qxd
02/Dec/2004
10:23
Page 5
Safety
VERSIONS AND ACCESSORIES
Conforms with EN 61010-1 for class 1 portable equipment.
When ordering please quote the full ordering number information.
Temperature
5° to 40°C
Ordering Numbers
Relative Humidity
Versions
≤80% for temperatures upto 31°C, decreasing linearly to 50% at 40°C
1400-110
ATC-1400A Transponder/DME
Equipment, 110 VAC operation
Bench
Test
1400-220
ATC-1400A Transponder/DME
Equipment, 220 VAC operation
Bench
Test
Altitude
≤4000 m (13,124 ft)
Mains Supply Fluctuations
≤±10% of the nominal voltage
Transient Overvoltages
Accessories
1401-110
T-1401 TACAN Bearing and DME Simulation,
110 VAC operation
1401-220
T-1401 TACAN Bearing and DME Simulation,
220 VAC operation
1402-110
I-1402 Mode 4 Transponder/Interrogator, 110 VAC
operation
1402-220
I-1402 Mode 4 Transponder/Interrogator, 220 VAC
operation
1403-110
S-1403DL Mode S Transponder, 110 VAC operation
1403-220
S-1403DL Mode S Transponder, 220 VAC operation
According to installation category II
Pollution Degree
2
Dimensions
426 mm wide, 185 mm high, 467 mm deep
16.8 in. wide, 7.3 in. high, 18.4 in. deep
Weight
20 kg (44 lbs.) approximately
1403MLD-110 S-1403DL/MLD Mode S with Level Diversity,
110 VAC operation
1403MLD-220 S-1403DL/MLD Mode S with Level Diversity,
220 VAC operation
1404-110
SI-1404 Modes S & 4 Transponder with MLD,
110 VAC
1404-220
SI-1404 Modes S & 4 Transponder with MLD,
220 VAC
Options
AC1000
Non-coherent SLS option
All Aeroflex Avionics products delivered with Factory Certificate Of Calibration
For the very latest specifications visit
www.aeroflex.com
atc1400aiss3.qxd
02/Dec/2004
10:23
Page 6
atc1400aiss3.qxd
02/Dec/2004
10:23
Page 7
For the very latest specifications visit
www.aeroflex.com
atc1400aiss3.qxd
02/Dec/2004
10:23
Page 8
.
CHINA Beijing
Tel: [+86] (10) 6467 2761 2716
Fax: [+86] (10) 6467 2821
GERMANY
Tel: [+49] 8131 2926-0
Fax: [+49] 8131 2926-130
SCANDINAVIA
Tel: [+45] 9614 0045
Fax: [+45] 9614 0047
CHINA Shanghai
Tel: [+86] (21) 6282 8001
Fax: [+86] (21) 62828 8002
HONG KONG
Tel: [+852] 2832 7988
Fax: [+852] 2834 5364
SPAIN
Tel: [+34] (91) 640 11 34
Fax: [+34] (91) 640 06 40
FINLAND
Tel: [+358] (9) 2709 5541
Fax: [+358] (9) 804 2441
INDIA
Tel: [+91] 80 5115 4501
Fax: [+91] 80 5115 4502
UK Burnham
Tel: [+44] (0) 1682 604455
Fax: [+44] (0) 1682 662017
FRANCE
Tel: [+33] 1 60 79 96 00
Fax: [+33] 1 60 77 69 22
KOREA
Tel: [+82] (2) 3424 2719
Fax: [+82] (2) 3424 8620
As we are always seeking to improve our products,
the information in this document gives only a general
indication of the product capacity, performance and
suitability, none of which shall form part of any contract. We reserve the right to make design changes
without notice. All trademarks are acknowledged.
Parent company Aeroflex, Inc. ©Aeroflex 2004.
UK Stevenage
Tel: [+44] (0) 1438 742200
Fax: [+44] (0) 1438 727601
Freephone: 0800 282388
USA
Tel: [+1] (316) 522 4981
Fax: [+1] (316) 522 1360
Toll Free: 800 835 2352
w w w.aeroflex.com
[email protected]
Part No. 46891/033, Issue 3, 08/03
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement