EVSemE Range

EVSemE Range
EVSemE Range
Emergency fluorescent
fitting
■
■
■
Product characteristics
▼▼▼▼▼
TYPICAL
APPLICATIONS
Refineries
Marine
Petrochem/Chemical
Pharmaceutical
Gas & Dust
EVS-E family design
Battery duration: 1h30
Disconnectable gear tray on EVSem version
■
■
■
■
■
■
Grey fibreglass reinforced polyester body with polycarbonate injected diffuser
White painted metal gear tray with:
- G13 lampholder (bi-pin) or Fa6 (single pin)
- electronic ballast + inverter, power factor 0.98
- power supply: standard 220V to 240V, 50 to 60Hz (120V option)
Ni-Cad 1h30 duration battery
Two M20 polyamide cable glands
One M20 polyamide plug
Set of 2 fixing brackets
CERTIFICATION STANDARD: CENELEC EN 50014, 50017, 50018, 50019, 50281-1-1
EC TYPE EXAMINATION CERTIFICATE: under the new directive 94/9/EC: LCIE 97
ATEX 6001
II 2 G and D, IP6x T6 (85°C) for D
EExed IIC T4 or EExedq IIC T4 (with Fa6 lampholder)
EExeds IIC T4 or EExedqs IIC T4 (with G13 lampholder)
Ingress protection: IP66
Shock resistance: IK09 10Joules
Glow wire test: 960°C
36
Z.I. - Avenue Henri Beaudelet B.P. 27 - 77831 Ozoir Cedex - France - Tel. +33 (0)1 64 40 27 26 - Fax +33 (0)1 64 40 20 11
Zone 1
+ zone 2
EEx “e”
Increased
safety
Technical specifications for EVSem-E
Enclosure
Options: M20 polyamide cable gland for non-armoured
cable, Ø 10-15mm
M25 polyamide cable gland for non-armoured cable,
Ø 13-19 mm
M20 – M25 metallic cable gland for non-armoured
cable series PE (see page 123)
M20 – M25 metallic cable gland for armoured cable
series PEP (see page 123), with brass connecting plate
Fibreglass reinforced polyester body
Polycarbonate diffuser (protective coating optional)
Ingress rating: IP66 (EN60529), EPDM cellular gaskets
Stainless steel screws
Brass fixing inserts and nickel chromed brass
locking bar (stainless steel optional)
Temperature
Terminal block
Ambient temperature range: -10°C to +40°C
Surface temperature classification:T4 (gas),T6 85°C (dust)
Up to 4mm2 (rigid wire), 2.5mm2 (flexible wire)
Standard:Terminals supplied for L, N, PE, terminal 1 and
terminal 2 and looping.
Options: 5 poles through wiring L1, L2, L3, N, PE
(Imax=16A) for 40 W only.
The L terminal is the battery charging terminal, wich will
be permanently switched on.
A non-polarised/switch, connected between terminals 1 and
2, selects function: contact closed, lighting in maintained
mode; contact open; lighting in non-maintained mode.
Protection class: I
Automatic switch off of power supply and battery on
opening
Rated voltages
Standard: single / dual tube electronic ballast
AC 220 – 240V, 50-60Hz
Options: twin tube electronic ballast (automatic
cut-out of failed lamp)
AC220 to 240V, 50 to 60Hz
Twin tube electronic ballast AC 120V, 50-60Hz
Battery: Ni-Cad 7.2V 4Ah in flameproof case
(automatic cut-out of defective lamp)
Lumen output in emergency mode (1 tube lit): 40%
at 18W, 33% at 36W
Battery duration in emergency mode: 18W = 3h,
36W = 1h30’
Battery charge monitored by LED
Photometric
data
90
110
100
70
60
50
50
30
30
20
10
0
10
20
For 1000 lm, with 1 lamp
90
Standard: 2 chromed zinc ceiling mounting brackets (V015)
Options:
Stainless steel ceiling mounting brackets (V016)
1 1/4” and 1 1/2” (V018), 2” (V019) chromed zinc pole
mountings
1 1/4” and 1 1/2” (V021), 2” (V022) stainless steel pole
mountings
Steel hinged bracket + cataphoresis (V023)
Rapid ceiling mounting bracket with aluminium clip (V014)
Chromed zinc ceiling suspension hook (VO24)
Standard:Two M20 polyamide cable glands for nonarmoured cable, Ø 8-13mm
One M20 polyamide plug
60
40
Fixing
Cable entries
70
0.68 H + 0.10 T
Tube G13 bi-pin T8 Ø 26 coolwhite 4000°k
(other colour temperatures on request)
Fa6 single pin tube T12 Ø 38 coolwhite 4000°k
(other colour temperatures on request)
Superior to 0.98
100 90
80
40
Lamps (supplied on request)
Power factor
110
25
50
75
100
125
150
175
200
80
1
100
110
25
50
75
100
125
150
175
200
10
80
70
60
50
100 90
80
70
60
50
40
40
0.63 G + 0.07 T
30
30
20
10
0
10
20
For 1000 lm, with 2 lamps
Installation and maintenance instruction leaflet NT 34 available on request
Technical specifications for EVSem
The technical specifications are the same as the
EVSem-E except for:
Terminal block
Up to 6mm2 (rigid wire), 4mm2 (flexible wire)
Terminals for L, N, PE, terminal 1 and terminal 2
Looping and through wiring not available
- Disconnectable gear tray
Installation and maintenance instruction leaflet NT 34 available on request
Reference *
Bi-pin
Single pin
(G13)
(Fa6)
EVS120emE
EVS140emE
EVS220emE
EVS240emE
EVM120emE
EVM140emE
EVM220emE
EVM240emE
Rating
Nominal
(in W)
current
Dimensions (in mm)
Weight
A
B
C
D
E
(in kg)
785
1370
785
1370
170
170
170
170
137
137
137
137
400
700
400
700
432
900
432
900
7.5
9.5
8.5
10.5
(in A)
1
1
2
2
x
x
x
x
18/20
36/40
18/20
36/40
0.09
0.17
0.17
0.33
* Disconnectable gear tray version 36/40W, remove E (eg.: EVS 240em)
Spare Parts
Note
004
005
003
002
007
001
V001
V002
V004
V005
Transparent diffuser
Gasket
Complete gear tray*
XIN switch
*Define type, rating and operating voltage
Fixing accessories
and dimensions:
see EVS-E page 35
004
008
009
V006
V012
V008
V009
002
EExe terminal block
Electronic ballast EExd*
G13 bi-pin lampholder
Single pin lampholder Fa6
37
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement