units geräte - Marco D`Polo

units geräte - Marco D`Polo
UNITS
GERÄTE
16
www.ackermanninstrumente.de
Cameras
CAMERAS
16-2008PAL
Economy 1CCD camera, 1/3’’ chip, PAL version
16-2008NTSC
Economy 1CCD camera, 1/3’’ chip, NTSC version
Including
- C-Mount camera head with cable (3 m)
- BNC cable
- Y/C cable
- Power cord
- Operating Manual
Please note that coupler has to be ordered separately (see page 16-5)
Technical Data
Features
Resolution
752 x 582 PAL; 768 x 494 NTSC
Definition
825 lines
Sensitivity
0,9 lux
Signal / Noise ratio
64 dB
Electronic shutter
1/100 000 sec.
White Balance
Automatic push
Cable length
3.0 meters
Outputs
1 x Y/C / 1 x BNC
Size of the control unit
300 x 300 x 66 mm
Weight of the control unit
2,5 kg
Main voltage
115 - 230 VAC
Power consumption
25 VA
Frequency
50 - 60 Hz
Fuses
2 x T 800 mA - 250 V
Standards
Classification 93/42 EG
> Electronic shutter for camera controlled brightness regulation
> Noise free image resolution
> HAD chip technology (Hyper Active Digital)
> No flickering image or loss of signal data due to digital processing
> Easy and safe handling due to user friendly design and function
> One hand quick focusing
> For left and right hands use
> Aperture and boost function
> Automatic white balance
> Water proof camera head
Protection Class 1
Type BF
IEC 601.1, IEC 601.1.2
MPG
16-2
www.ackermanninstrumente.de
Cameras
CAMERAS
16-2010PAL
1CCD camera, 1/3’’chip, PAL version
16-2010NTSC
1CCD camera, 1/3’’chip, NTSC version
16-2010DV-PAL
1CCD camera, 1/3’’chip, PAL version,
with DV output (Firewire)
16-2010DV-NTSC
1CCD camera, 1/3’’chip, NTSC version,
with DV output (Firewire)
Including
- C-Mount camera head with cable (3,6 m)
16
- BNC cable
- Y/C cable
- Firewire connection cable (on DV models only)
- Power cord
- Operating Manual
Please note that coupler has to be ordered separately (see page 16-5)
Technical Data
Features
Resolution
752 x 582 PAL; 768 x 494 NTSC
Definition
855 lines
Sensitivity
0,23 lux
Signal / Noise ratio
49 dB
Electronic shutter
1/100 000 sec.
Auto exposure
5 window areas
White Balance
Automatic push
Video enhancement
Yes
Cable length
3,6 meters
Outputs
2 x Y/C / 2 x BNC
Size of the control unit
300 x 300 x 66 mm
Weight of the control unit
2,5 kg
Main voltage
115 - 230 VAC
Power consumption
25 VA
Frequency
50 - 60 Hz
Fuses
2 x T 800 mA - 250 V
Standards
Classification 93/42 EG
> Electronic shutter for camera controlled brightness regulation
> Noise free image resolution
> HAD chip technology (Hyper Active Digital)
> No flickering image or loss of signal data due to digital processing
> Easy and safe handling due to user friendly design and function
> One hand quick focusing
> For left and right hands use
> Many parameters (like brightness, aperture, red shift, blue shift
etc.) can be adjusted via on-screen-menu.
> 10 different users can save their own settings
> Programmable buttons on the camera head
> Automatic white balance
> Water proof camera head
Protection Class 1
Type BF
IEC 601.1, IEC 601.1.2
MPG
IPX 0
www.ackermanninstrumente.de
16-3
Cameras
CAMERAS
16-2011PAL
3CCD camera, 1/4” chip, PAL version
16-2011NTSC
3CCD camera, 1/4” chip, NTSC version
16-2011DV-PAL
3CCD camera, 1/4” chip, PAL version,
with DV output (Firewire)
16-2011DV-NTSC 3CCD camera, 1/4” chip, NTSC version,
with DV output (Firewire)
Including
- C-Mount camera head with TV coupler and cable (3,6 m)
- RGB cable
- BNC cable
- Y/C cable
- Firewire connection cable (on DV models only)
- Power cord
- Operating Manual
Technical Data
Features
Resolution
3 x 752 x 582 PAL; 3 x 768 x 494 NTSC
Definition
1155 lines
Sensitivity
0,18 lux
Signal / Noise ratio
60 dB
Electronic shutter
1/100 000 sec.
Auto exposure
Variable
White Balance
Automatic push
Video enhancement
Yes
Cable length
3,6 meters
Outputs
1 x RGB / 1 x Y/C / 1 x BNC
Size of the control unit
300 x 300 x 66 mm
Weight of the control unit
2,5 kg
Main voltage
115-230 VAC
Power consumption
25 VA
Frequency:
50 - 60Hz
Fuses
2 x 800 mA - 250 V
Standards
Classification 93/42 EG
> Electronic shutter for camera controlled brightness regulation
> Noise free image resolution
> HAD chip technology (Hyper Active Digital)
> No flickering image or loss of signal data due to digital processing
> Easy and safe handling due to user friendly design and function
> One hand quick focusing
> For left and right hands use
> Many parameters (like brightness, aperture, red shift, blue shift
etc.) can be adjusted via on-screen-menu.
> 10 different users can save their own settings
> Programmable buttons on the camera head
> Automatic white balance
> Water proof camera head
Protection Class 1
Type BF
IEC 601.1, IEC 601.1.2
MPG
IPX 0
16-4
www.ackermanninstrumente.de
TV Coupler
TV COUPLER
15-1702CLD-15
TV coupler
F = 15 mm
15-1702CLD
TV coupler
F = 23 mm
15-1702CLD-26
TV coupler
F = 26 mm
15-1702CLD-28
TV coupler
F = 28 mm
16
www.ackermanninstrumente.de
15-1702ZM
Zoom TV coupler
F = 25-40 mm
15-1705
Beam splitter
F = 25 mm
16-5
Video laparoscope
VIDEO LAPAROSCOPE
16-2032PAL
Video Laparoscope 10mm 0°, PAL Version
16-2032NTSC
Video Laparoscope 10mm 0°, NTSC Version
Including
- BNC cable
- Y/C cable
- Power cord
- Operating Manual
Features
Technical data
Diameter
10 mm
Direction of view
0°
Working length
350mm
Image Sensor
1CCD 1/4“
Resolution
752 x 582 PAL; 768 x 454 NTSC
Definition
520 Lines
Outputs
1 x Y/C / 1 x BNC
Signal / Noise Ratio
> 46 dB
High-Speed-Shutter
max. 1/100.000 sec
White balance
Automatic push
Illumination
Standard : 2.500 lux F8 (3.000K)
> Chip-on-tip technology provides a rod-lens-free image
> The optical quality has reached a new level, due to
dramatically reduced number of optical interfaces
> Provides a brilliant depth of focus
> Extremely bright picture
> Excellent sharpness of the picture
> Very good reproduction of the colous and a high contrast
> Modular system
> Fully autoclavable
Minimum : 3 lux / F 1.4 (AGC on)
Main voltage
115 – 230 VAC
Power consumption
20 W
Frequency
50 - 60 Hz
Fuses
2 x T 2 A – 250 V
Weight control unit
2,5 kg
Scope: 500g
Dimensions
Control unit 60 x 300 x 300 mm
Standard camera cable
3m
Protection class
I
Classification
BF without function group
with 1 Patient circuit
Test standard
16-6
IEC 601-1, IEC 601-1-2, MPG
www.ackermanninstrumente.de
Light sources
LIGHT SOURCES
16-2023
2 x 250 W Halogen light source
Including
- Power cord
- Operating Manual
16
Features
Technical data
Type of lamp
Halogen lamp
Perfoformance
2 x 250 W
Colour temperature
3200° Kelvin
Lamp lifetime:
50 hours (Average value at:
> In case of malfunction of one lamp you can easy changeover
to the second lamp by an ergonomic front switch.
> Mechanical iris = constant colour temperature
> Simple and fast lamp change
30 min. ON and 15 min. OFF)
Light cable connection
Storz/Ackermann (others on request)
Electrical requirements
105 or 230 V ~ / 50 or 60 Hz (manual switch
on the rear panel)
Power Consumption
maximum 270 VA
Dimensions
300 x 311 x 90 mm
Weight
3,9 kg
Fuses
2 x T 4A
Temperature range:
+10°C to +35°C - in function
Max. relative air humidity
85% - in function
Temperature range:
-20°c to +45°C - in storage
Max. relativee air humidity
85% in storage
Electr. protection class
(IPXO) Not protected against water
CE standard
Conform to the European directive 93/42/CEE
Safety measurements
Not adapted to a use close to a mixture of
inflammable anaesthetic with air, oxygen or
nitrous oxide
www.ackermanninstrumente.de
16-7
Light sources
LIGHT SOURCES
16-2020
100 W Xenon light source
Including
- Power cord
- Operating Manual
Technical Data
Features
Type of lamp
Xenon lamp
Performance
100 W / comparable with 300 W
Lamp geometry
Ackermann® Xenon lamp with focusing mirror
Colour temperature
6000° Kelvin
Light cable connection
Ackermann (Wolf, Olympus with other adapters)
Lamp life time
500 hours (Av. value: 30 min ON / 15 min. OFF)
Main voltage
100 - 230 VAC
Power consumption
260 VA
Frequency
50 - 60 Hz
Fuses
2 x T 4A
Dimensions
300 x 311 x 125 mm
Weight
5,0 kg
Temperature range
+10° C to +40° C - in function
Max. relative air humidity
85% - in function
Temperature range
-20° C to +45° C - in storage
Max. relative air humidity
85% - in storage
Classification
CF (cardiac floation)
Electr. protection class
IPX0, not protected against waterfalls
CE standard
Conform to the European directive 93/42/CEE
Safety measurements
Not adapted to a use close to a mixture of
>
>
>
>
>
>
>
>
Manual increase and decrease of light intensity
Stand by function to protect the lamp for longer life
Power on/off LED indicator
LCD display for the technical functions
Mechanical iris = constant colour temperature
Indication of the minimal and maximal levels of light
Continuous service
All Electromagnetic Compatibility (EMC) requirements were hold
into account in the development of this light source.
> Simple and fast lamp change
High focus light equivalent to 300 W light
sources due to parabolic mirror focusing the
light.
Competitors (no focus)
inflammable anaesthetic with air, oxygen or
nitrous oxide
16-8
www.ackermanninstrumente.de
Light sources
LIGHT SOURCES
16-2021
180 W Xenon light source
Including
- Power cord
- Operating Manual
16
Technical Data
Features
Type of lamp
Xenon lamp
Performance
180 W / comparable with 600 W
Lamp geometry
Ackermann® Xenon lamp with focusing mirror
Colour temperature
6000° Kelvin
Ligth cable connection
Ackermann (Wolf, Olympus with other adapters)
Lamp life time
500 hours (Av. value: 30 min ON / 15 min. OFF)
Main voltage
100 - 230 VAC
Power consumption
260 VA
Frequency
50 - 60 Hz
Fuses
2 x T 4A
Dimensions
300 x 311 x 125 mm
Weight
5,0 kg
Temperature range
+10° C to + 40° C - in function
Max. relative air humidity
85% - in function
Temperature range
-20° C to +45° C - in storage
Max. relative air humidity
85% - in storage
Classification
CF (cardiac floation)
Electr. protection class
IPX0, not protected against waterfalls
CE standard
Conform to the European directive 93/42/CEE
Safety measurements
Not adapted to a use close to a mixture of
>
>
>
>
>
>
>
>
Manual increase and decrease of light intensity
Stand by function to protect the lamp for longer life
Power on/off LED indicator
LCD display for the technical functions
Mechanical iris = constant colour temperatur
Indication of the minimal and maximal levels of light
Continuous service
All Electromagnetic Compatibility (EMC) requirements were hold
into account in the development of this light source.
> Simple and fast lamp change
High focus light equivalent to 600 W light
sources due to parabolic mirror focusing the
light.
Competitors (no focus)
inflammable anaesthetic with air, oxygen or
nitrous oxide
www.ackermanninstrumente.de
16-9
Light sources
LIGHT SOURCES
16-2022
300 W Xenon light source
Including
- Power cord
- Operating Manual
Technical Data
Features
Type of lamp
Xenon lamp
Performance
300 W / comparable with 900 W
Lamp geometry
Ackermann® Xenon lamp with focusing mirror
Colour temperature
6200° Kelvin
Ligth cable connection
Ackermann (Wolf, Olympus with other adapters)
Lamp life time
500 hours (Av. value: 30 min ON / 15 min. OFF)
Main voltage
100 - 230 VAC
Power consumption
260 VA
Frequency
50 - 60 Hz
Fuses
2 x T 4A
Dimensions
300 x 311 x 125 mm
Weight
5,0 kg
Temperature range
+10° C to + 40° C - in function
Max. relative air humidity
85% - in function
Temperature range
-20° C to +45° C - in storage
Max. relative air humidity
85% - in storage
Classification
CF (cardiac floation)
Electr. protection class
IPX0, not protected against waterfalls
CE standard
Conform to the European directive 93/42/CEE
Safety measurements
Not adapted to a use close to a mixture of
>
>
>
>
>
>
>
>
Manual increase and decrease of light intensity
Stand by function to protect the lamp for longer life
Power on/off LED indicator
LCD display for the technical functions
Mechanical iris = constant colour temperature
Indication of the minimal and maximal levels of light
Continuous service
All Electromagnetic Compatibility (EMC) requirements were hold
into account in the development of this light source.
> Simple and fast lamp change
High focus light equivalent to 900 W light
sources due to parabolic mirror focusing the
light.
Competitors (no focus)
inflammable anaesthetic with air, oxygen or
nitrous oxide
16-10
www.ackermanninstrumente.de
Laparoscopy insufflator
LAPAROSCOPY INSUFFLATOR
16-2040N
Insufflator 20 L
Including
- 4 pcs. disposable Y-tubing set fitted with a viral filter
- Open-end spanner
- Power cord
- Operating Manual
16
Technical Data
Features
Main voltage
100-240 VAC
Power consumption
40 VA
Frequency
50 – 60 Hz
Fuses
2 x 2,5 AT – 250 V time-lag fuses - UR
Dimensions
300 x 340 x 145 mm
Weight
5 kg
Max. gas flow
20 L
Pressure selection
0 – 24 mmHg (accuracy of 1 mmHg)
Temperature range
+10°C to +40°C - in function
Max. relative air humidity
30 to 75 % - in function
Temperature range
+10°C to +40°C – in storage
Max. relative air humidity
20 to 85 % - in storage
Standards
Classification 93/43 EG
Accessories
Protection Class 1
16-2040-2000
High pressure hose with US bottle connection
Type BF
16-2040-2001
High pressure hose with DIN bottle connection
IEC 601.1
16-2040-2002
High pressure hose with Pin Index
16-2040-100YD
Disposable Y-Tubing set with viral filter (10 pcs.)
>
>
>
>
Inbuilt gas pre-heating system
External desufflation valve to avoid cross-contamination
Pressure controlled insufflation
Large display showing all the important measures during
operation
> Bottle pressure monitoring
> Adjustment and pre-selection possibilities
MPG
IPX 0
www.ackermanninstrumente.de
bottle connection
16-11
Laparoscopy insufflator
LAPAROSCOPY INSUFFLATOR
16-2041N
Insufflator 30 L
Including
- 4 pcs. disposable Y-tubing set fitted with a viral filter
- Open-end spanner
- Power cord
- Operating Manual
Technical Data
Features
Main voltage
100-240 VAC
Power consumption
40 VA
Frequency
50 – 60 Hz
Fuses
2 x 2,5 AT – 250 V time-lag fuses - UR
Dimensions
300 x 340 x 145 mm
Weight
5 kg
Max. gas flow
30 L
Pressure selection
0 – 24 mmHg (accuracy of 1 mmHg)
Temperature range
+10°C to +40°C - in function
Max. relative air humidity
30 to 75 % - in function
Temperature range
+10°C to +40°C – in storage
Max. relative air humidity
20 to 85 % - in storage
Standards
Classification 93/43 EG
Accessories
Protection Class 1
16-2040-2000
High pressure hose with US bottle connection
Type BF
16-2040-2001
High pressure hose with DIN bottle connection
IEC 601.1
16-2040-2002
High pressure hose with Pin Index
16-2040-100YD
Disposable Y-Tubing set with viral filter (10 pcs.)
>
>
>
>
Inbuilt gas pre-heating system
External desufflation valve to avoid cross-contamination
Pressure controlled insufflation
Large display showing all the important measures during
operation
> Bottle pressure monitoring
> Adjustment and pre-selection possibilities
MPG
IPX 0
16-12
bottle connection
www.ackermanninstrumente.de
Laparoscopy insufflator
LAPAROSCOPY INSUFFLATOR
16-2042N
Insufflator 45 L
Including
- 4 pcs. disposable Y-tubing set fitted with a viral filter
- Open-end spanner
- Power cord
- Operating Manual
16
Technical Data
Features
Main voltage
100-240 VAC
Power consumption
40 VA
Frequency
50 – 60 Hz
Fuses
2 x 2,5 AT – 250 V time-lag fuses - UR
Dimensions
300 x 340 x 145 mm
Weight
5 kg
Max. gas flow
45 L
Pressure selection
0 – 24 mmHg (accuracy of 1 mmHg)
Temperature range
+10°C to +40°C - in function
Max. relative air humidity
30 to 75 % - in function
Temperature range
+10°C to +40°C – in storage
Max. relative air humidity
20 to 85 % - in storage
Standards
Classification 93/43 EG
Accessories
Protection Class 1
16-2040-2000
High pressure hose with US bottle connection
Type BF
16-2040-2001
High pressure hose with DIN bottle connection
IEC 601.1
16-2040-2002
High pressure hose with Pin Index
16-2040-100YD
Disposable Y-Tubing set with viral filter (10 pcs.)
>
>
>
>
Inbuilt gas pre-heating system
External desufflation valve to avoid cross-contamination
Pressure controlled insufflation
Large display showing all the important measures during
operation
> Bottle pressure monitoring
> Adjustment and pre-selection possibilities
MPG
IPX 0
www.ackermanninstrumente.de
bottle connection
16-13
Hysteroscopy insufflator
HYSTEROSCOPY INSUFFLATOR
15-1731
Hysteroflator
Including
- Disposable insufflation hose
- Silicone insufflation tube
- Luer Lock connector
- Hydrophobic sterile filter (2 pcs.)
- Open-end wrench set
- Power cord
- Operating manual
Technical Data
Features
Main voltage
100-240 VAC
Power consumption
60 VA
Frequency
50 - 60 Hz
Safety class
1
Dimensions
320 x 300 x 145 mm
Weight
5 kg
Max. gas flow
0 - 100 ml/min (CO2)
Pressure selection
0 - 150 mm Hg
MedGeVO-Group
3
Standards
Made of UL listed components
VDE 0750/IEC 601, GS/TÜV, CE
16-14
> The Hystero-Insufflator is used for safe distension of the uterine
cavity.
> The unit is based on the results of many clinical studies and was
developed in close collaboration with eminent gynecologists.
> The use of state-of-the-art microprocessor technology and sensor
systems are further advantages of this unit.
> The unit is very simple to use, due to the direct digital selections of
the required pressure and flow rate. An “intelligent“ control
system regulates and monitors these parameters.
> Absolute safety is achieved by the electronic and mechanical safety
features, which monitor each other (redundant safety).
> Continuous insufflation without pulsation.
> Gas pressure and gas flow are seperately adjustable.
> Ergonomic layout of displays and controls, in combination with
self-explanatory graphical readouts, allow intuitive operation.
> Compact system size offers mechanical stability and shielding
against RF interference as well as attachment options for various
accessories.
www.ackermanninstrumente.de
Urology irrigation pump
UROLOGY IRRIGATION PUMP
15-1715
UroSurgiSystem
Including
- Autoclavable tubing set
- Autoclavable measuring chamber
- Autoclavable membrane protector
- Power cord
- Operating manual
16
Technical Data
Features
Main voltage
100 - 240 VAC
Power consumption
60 VA
Frequency
50-60 Hz
Device type
BF
Safety class
II a
Dimensions
300 x 260 x 93 mm
Weight
5 kg
Casing safety standard
IPX 1
Flow rate
0 - 1000 ml/min
Pressure range
10-150 mm Hg
Temperature range
+10 to +40° C
Accessories
Humidity
30% - 70%
15-1720-100
Tubing set autoclavable
Standards
in accordance with DIN IEC 601/1,
15-1720-300
Tubing set disposable (10 pcs.)
EN 55011 (CISPR); EN 50082, parts 1 + 2
15-1720-500
Measuring chamber autoclavable (10 pcs.)
CE 0297
15-1720-700
Membrane protector autoclavable (10 pcs.)
www.ackermanninstrumente.de
>
>
>
>
Touch free pressure measurement
Leakage liquid compensation
Preselection of pressure and flow
Continuous pressure roller pump system
16-15
Hysteroscopy irrigation pump
HYSTEROSCOPY IRRIGATION PUMP
15-1719
HysteroSurgiSystem
Including
- Autoclavable tubing set
- Autoclavable measuring chamber
- Autoclavable membrane protector
- Power cord
- Operating manual
Technical Data
Features
Main voltage
100 - 240 VAC
Power consumption
60 VA
Frequency
50-60 Hz
Device type
BF
Safety class
II a
Dimensions
300 x 260 x 93 mm
Weight
5 kg
Casing safety standard
IPX 1
Flow rate
0 - 500 ml/min
Pressure range
10-200 mm Hg
Temperature range
+10°C to +40°C
Accessories
Humidity
30% - 70%
15-1720-100
Tubing set autoclavable
Standards
in accordance with DIN IEC 601/1,
15-1720-300
Tubing set disposable (10 pcs.)
EN 55011 (CISPR); EN 50082, parts 1 + 2
15-1720-500
Measuring chamber autoclavable (10 pcs.)
CE 0297
15-1720-700
Membrane protector autoclavable (10 pcs.)
16-16
>
>
>
>
Touch free pressure measurement
Leakage liquid compensation
Preselection of pressure and flow
Continuous pressure roller pump system
www.ackermanninstrumente.de
Arthroscopy irrigation pump
ARTHROSCOPY IRRIGATION PUMP
15-1720
ArthroSurgiSystem
Including
- Autoclavable tubing set
- Autoclavable measuring chamber
- Autoclavable membrane protector
- Power cord
- Operating manual
16
Technical Data
Features
Main voltage
100 - 240 VAC
Power consumption
60 VA
Frequency
50-60 Hz
Device type
BF
Safety class
II a
Dimensions
300 x 260 x 93 mm
Weight
5,0 kg
Casing safety standard
IPX 1
Flow rate
0 - 1500 ml/min
Pressure range
10-150 mm Hg
Temperature range
+10 to +40° C
Accessories
Humidity
30% - 70%
15-1720-100
Tubing set autoclavable
Standards
in accordance with DIN IEC 601/1,
15-1720-300
Tubing set disposable (10 pcs.)
EN 55011 (CISPR); EN 50082, parts 1 + 2,
15-1720-500
Measuring chamber autoclavable (10 pcs.)
CE 0297
15-1720-700
Membrane protector autoclavable (10 pcs.)
www.ackermanninstrumente.de
>
>
>
>
Touch free pressure measurement
Leakage liquid compensation
Preselection of pressure and flow
Continuous pressure roller pump system
16-17
Laparoscopy suction/irrigation pump
LAPAROSCOPY SUCTION/IRRIGATION PUMP
-FOR USE WITH IRRIGATION BAGS16-2080
Double roller pump
Including
- Silicone suction/irrigation tubing set, non sterile, autoclavable
- Suction/irrigation cannula diam. 5 mm / 10 mm, autoclavable
- Adapter duct, autoclavable
- Pneumatic manual control with double-lumen control tube
autoclavable
- Fuses
- Power cord
- Operating manual
Technical Data
Features
Frequency
50-60 Hz
Power consumption
36 VA
Device typ
BF
Main voltage
100 - 240 VAC
Mains fuse T3, 15 A
Safety class
IIa
Construction
DIN EN 60601-1 (03.1996)
Radio interference suppression
DIN EN 60601-1-2 (10.2002)
Irrigation capacity
0 – 3.000 ml/min
Suction capacity
0 – 3.000 ml/min
Max. pressure
0 – 1.000 mm Hg
Temperature range
+10 to +40°C
Humidity
30 to 70%
Protection against sprinkler water
IPX 1
> The device, a suction-irrigation pump without pressure
monitoring is used in minimal invasive surgery.
> It can be utilized in all areas of endoscopic surgical operation
procedures where the body cavities are not completely filled
with fluid and where the volume of rinsing fluid is small in
proportion to the volume of the anatomical cavity.
> The pump system is well suited for utilization in the abdomen
and in the thorax.
Certificates
Dimensions (w x h x d)
300 mm x 93 mm x 260 mm
Accessories
Weight
approx. 6.5 kg
16-2080-100
Autoclavable tubing set
16-2080-1000
Pneumatic double footswitch
16-2080-200
Pneumatic manual control, autoclavable
16-2080-201
Suction/Irrigation cannula 5 mm
16-2080-202
Suction/Irrigation cannula 10 mm
16-2080-203
Adapter duct, autoclavable
16-2080-204
Double lumen control tube, autoclavable
16-18
www.ackermanninstrumente.de
Laparoscopy suction/irrigation pump
LAPAROSCOPY SUCTION/IRRIGATION PUMP
-FOR USE WITH IRRIGATION BOTTLES15-1730
Suction/irrigation pump (240 VAC)
15-1730-110V
Suction/irrigation pump (100 VAC)
Including
- Bottle holder for 2 L suction receptacle
- Bottle holder for 1 L rinsing bottle
- Reusable 2 L suction receptacle
- 2 Sterile filters with LL-connectors at both sides
- Puncture tube
16
- Autoclavable tubing set
- Power cord
- Operating manual
Technical Data
Features
Main voltage
100 or 240 VAC
Power consumption
120 VA
Frequency
50 - 60 Hz
Safety class
1
Dimensions
320 x 300 x 145 mm
Weight
5 kg
Rinsing performance
up to 3000 ml/min
MedGeVO-Group
3
Standards
Made of UL listed components
> Highest efficiency
> Aspirates and irrigates at up to 3 l / min
> Special filters ensure sterility
> No special adjustment necessary. Aspiration and irrigation are
regulated and selected by the instrument controls
> “Stand-by“ function for low noise level
> High quality components
VDE 0750, IEC 601, GS, TÜV, CE
Accessories
www.ackermanninstrumente.de
15-1730-1000
Disposable filter (50 pcs.)
15-1730-1001
Autoclavable tubing set
15-1730-1002
Disposable suction receptacle (25 pcs.)
15-1730-1003
Reusable suction receptacle
16-19
Sony DVD-Recorder
SONY DVD-RECORDER
15-1736
DVD-Recorder Sony DVO-1000MD
Including
Operation Manual, Protocol Manual
Technical Data
Quick Recording with Internal HDD
Main voltage:
100 - 240 VAC
Power Consumption:
35 VA
Frequency:
50 - 60 Hz
Operating temperature:
+5°C to +40°C
Storage Temperature:
-20°C to +60°C
Operating Humidity:
20% to 80%
Dimensions:
212 x 128.5 x 382 mm
Weight:
6 kg
Recording System:
DVD Recording, NTSC/PAL Switchable
Recording Format: Video:
MPEG-2 compression
Audio:
Dolby Digital format
Recordable Media:
DVD+RW (2.4 x and 4 x speed)
Recording Time:
HQ Mode: 60 minutes
SP Mode:
120 minutes
LP Mode:
180 minutes
Accessories
Medical Standards:
EN60601-1, EN60601-1-2, UL60601-1,
15-1736-102
SVRM-100A, Remote Control
CSA C22.2 No.60601.1
15-1736-103
FS-20, Foot Switch
16-20
The DVO-1000MD is equipped with an internal HDD (Hard Disk Drive) so
that recording always starts the moment the record button is pressed. The
DVO-1000MD begins recording to its HDD while the inserted DVD disc is
initialising itself for recording. Once the DVD disc is ready to record, the
DVO-1000MD starts writing onto the DVD disc using the data temporarily
stored on the HDD. This mechanism, not available on typical DVD recorders,
means it is possible to start recording right after the DVD disc is inserted, as
well as when resuming the unit from „stop“ mode. The HDD can also be
used for data recovery in the unlikely event that a recording fails on the
DVD disc.
www.ackermanninstrumente.de
Video printer
VIDEO PRINTER
15-1735
Video printer Sony UP 21 MD
The 15-1735 Sony videoprinter is the ideal choice for the endoscopy
application, it is very compact and will help to free the space in
medical carts.
Including
- Colour printing set
- Paper tray
- Thermal head cleaning kit
16
- Power cord
- Operating manual
Technical Data
Printing method
Dye Sublimation
Thermal head
403 dpi
Graduation
256 graduations, over 16 millions colours
Resolution
325 dpi
Printed area (NTSC)
S Size: Full 95,8 x 72,4 mm
L Size: Full 126,9 x 91,5 mm
Print speed
UPC-21S approx. 16 sec.
(High speed mode, NTSC)
UPC-21L approx. 16 sec.
Paper capacity
S Size tray: max. 80 sheets
L Size tray: max. 50 sheets
Power consumption
100 - 120 V 1,8 A | 220 - 240 V 1,0 A
Dimensions
212 x 125 x 395 mm
Weight
6,5 kg
Safety strandards
UL 1950, UP 2601-1 Listed (UC),
CSA C22.2 No. 950 (UC), EN60950,
EN60601-1 (UC)
www.ackermanninstrumente.de
16-21
Shaver System
SHAVER SYSTEM
Technical Data
16-2050
Shaver system complete with foot switch and
hand piece
16-2050-100
Hand piece only
16-2050-200
Foot pedal only
Features
Dimensions
90 x 360 x 268 mm
Weight
6 kg
Power input
230 V AC / 50 Hz
Capacity
50 VA
Primary fuse
2 x 1,6 AT
Type
Type B
Operating mode
Continous operation
IP Protection class
IXP 0
EN-class
2a
Connections
2 x hand piece
> Speed adjustable from 800 – 8000 RPM
> Ergonomic and light weight hand piece
> Silent and smooth motion
> Hand piece (with cable) autoclavable
> All functions can be either commanded on the control unit
or with the foot switch
> Shaver offers the possibility to connect 2 tools at the
same time (for example hand piece and saw).
1 x foot switch
Power cord
16-22
230 V, 10 A, 3-pole
www.ackermanninstrumente.de
Flat screens
FLAT SCREENS
16-2030
Flat screen for medical applications 17“
Including
- Power transformer
- Y/C and RGB connection cable
- Power cord
- Operating manual
16
Technical Data
Features
Screen
17“
Definition
920 lines
Max. output resolution
1280 x 1024 Pixels
Max. numbers of colours
16,7 Mio.
Automatic selection
PAL / SECAM / NTSC / M-NTSC
Input
Y/C, RGB
Dimensions
392 x 338 x 123 mm
Weight
5,6 kg
Power supply
85 - 265 Volt, 47 - 63 Hz
Power consumption
35 VA
Standards
Complies with IEC 601 / VDE 0750
www.ackermanninstrumente.de
> For medical cameras
> Many parameters can be adjusted via on-screen-menu
16-23
Flat screens
FLAT SCREENS
16-2031
Flat screen for medical applications 19“
Including
- Power transformer
- Y/C and RGB connection cable
- Power cord
- Operating manual
Technical Data
Features
Screen
19“
Definition
1090 lines
Max. output resolution
1280 x 1024 Pixels
Max. numbers of colours
16,7 Mio
Automatic selection
PAL / SECAM / NTSC / M-NTSC
Input
Y/C, RGB
Dimensions
442 x 338 x 123 mm
Weight
6,6 kg
Power supply
85 - 265 Volt, 47 - 63 Hz
Power consumption
35 VA
Standards
Complies with IEC 601 / VDE 0750
16-24
> For medical cameras
> Many parameters can be adjusted via on-screen-menu
www.ackermanninstrumente.de
Equipment trolley
EQUIPMENT TROLLEY
15-1740
Equipment trolley
Including
- 4 shelves
- 1 deposit console 60 x 49 cm adjustable, with handle
- 3 deposit consoles 60 x 49 cm, adjustable
- 1 drawer unit with storage tray 60 x 49 cm
- 4 wheels, 2 with brakes
16
Technical Data
Accessories
Dimensions
142,8 x 71,4 x 62,5 cm
15-1741-100
Holder for gas bottles (5 and 10 L)
Load
50 kg
15-1741-200
Holding arm for flat screens
Colour
light grey
15-1741-400
Holder for camera head
Standards
CE
15-1741-500
Cable/tube holding arm
15-1741-600
Holder for infusion bottles
15-1741-700
Isolating Transformer
www.ackermanninstrumente.de
16-25
Cleaning Accessories
CLEANING ACCESSORIES
16-26
15-1681
Cleaning gun
15-1680
Adapters for cleaning gun
13-1678
Cleaning brush for 3 mm instruments, 330 mm
13-1678-45
Cleaning brush for 3 mm instruments, 450 mm
13-1679
Cleaning brush for 5 mm instruments, 330 mm
13-1679-45
Cleaning brush for 5 mm instruments, 450 mm
13-1680
Cleaning brush for 10 mm instruments, 330 mm
13-1680-45
Cleaning brush for 10 mm instruments, 450 mm
www.ackermanninstrumente.de
Cleaning Accessories
CLEANING ACCESSORIES
15-1690
Aluminium container for endoscopes
465 x 280 x 135 mm
16
www.ackermanninstrumente.de
15-1695
Endoscope case, 44 x 9 x 5 cm
15-1696
Instrument-sterilizing case, 52 x 25 x 17 cm
16-27
Cleaning Accessories
CLEANING ACCESSORIES
Endoscope wire basket
15-1697
290 x 80 x 52 mm with silicone position pad
15-1697-100
460 x 80 x 52 mm with silicone position pad
15-1697-200
670 x 80 x 52 mm with silicone position pad
15-1699
Instrument-sterilizing case for 16 instruments,
Ø 5 or 10 mm and 64 x 31 x 15 cm
16-28
www.ackermanninstrumente.de
Notes
NOTES
16
www.ackermanninstrumente.de
16-29
Notes
NOTES
16-30
www.ackermanninstrumente.de
Notes
NOTES
16
www.ackermanninstrumente.de
16-31
Finest Surgical Technology
ACKERMANN INSTRUMENTE GmbH, GERMANY
Eisenbahnstraße 65-67
78604 Rietheim-Weilheim
Phone: ++49 (0) 74 61 / 9 66 17-0
Fax:
++49 (0) 74 61 / 9 66 17-70
[email protected]
www.ackermanninstrumente.de