TECHNICAL SPECIFICATIONS
ENVIRONMENTAL CONDITIONS
EN
Ambient/Storage temperature 0 ... +50 / °C -25... +70 °C
Max. humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
Relative Humidity
Protection Class
According to EN60529; Front panel: IP65 Rear panel : IP20
Height
Max. 2000m
Instruction Manual
RS Pro 35 x 77mm Digital Timer
Stock Number: 124-1077, 124-1078
Do not use the device in locations subject to corrosive and flammable gasses.
Please read this document carefully before using this product. The guarantee will be invalidated if the device is
damaged by not following instructions detailed in the manual. The company shall not be responsible for any damage
or losses however caused, which may be experienced as a result of the installation or use of this product.
* 77 x 35mm sized.
* Dual contact output for timing control.
* External start, reset, and gate inputs.
* Hours - minutes and minutes - seconds indications can be selected.
* Scale 0:01 .... 99:59 minutes
OUT1
OUT1
HOUR
H
OUT2
ELECTRICAL CHARACTERISTICS
Supply
Power Consumption
Wiring
Scale
Sensitivity
Time Accuracy
Indıcator
EMC
Safety Requirements
MIN
M
START
SET
SET
0:01 .... 99:59 hours
* Time increasing and decrement steps can be adjusted.
* Counting in downward direction.
* Start and stop process can be controlled by the front panel.
* 8 different warning tones.
* Upper and lower limits can be adjusted to setpoint value.
* CE marked according to European Norms.
STOP
230V AC ±%10, 50/60Hz or 24V AC/DC ±%10, 50/60Hz
Max. 7VA
2.5mm² screw-terminal
Selectable 99:59 min. or hour.
1 second.
±%1
4 digits, 12.5mm, 7 segment red LED
EN 61326-1: 2013 (Performance criterion B is satisfied for EN 61000-4-3)
EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)
OUTPUT
Out
Life Expectancy for Relay
2 Relays: 250V AC, 8A (for resistive load), NO and NC control output.
30.000.000 Switching for no-load operation; 300.000 switching for 8A resistive load at 250VAC.
START INPUT
Input Type
Mechanical contact (Minimum = 50ms)
RESET INPUT
Input Type
Mechanical contact (Minimum = 50ms)
GATE INPUT
230V ac
CONNECTION DIAGRAM
2x Relays
Input Type
2x Relays
HOUSING
Mechanical contact (Minimum = 50ms)
Housing Type
Dimensions
Weight
Enclosure Materials
1241077 & 1241078 is intended for installation within control panels. Make sure that the device is
used only for intended purpose. The shielding must be grounded on the instrument side. During an
installation, all of the cables that are connected to the device must be free of electrical power. The
device must be protected against inadmissible humidity, vibrations, severe soiling. Make sure
that the operation temperature is not exceeded. All input and output lines that are not connected to
the supply network must be laid out as shielded and twisted cables. These cables should not be close to the
power cables or components. The installation and electrical connections must be carried out by a qualified staff
and must be according to the relevant locally applicable regulations.
While cleaning the device, solvents (thinner, gasoline, acid etc.) or corrosive materials must not be used.
Dimensions
DIGITAL TIMER
DIGITAL TIMER
Made In Turkey
5
6
7
8
10
+12V
START
RESET
9
11 12
2
Made In Turkey
Fuse should
be connected.
SN: XXXXXXXXX
Neutral
FOR MORE INFORMATION VISIT THIS SITE
http://www.rs-components.com/index.html
1/4
1
Phase
Note 1) Mains supply cords shall meet the requirements
of IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the
230V AC
power supply switch shall bring the identification of
Supply
the relevant instrument and it should be easily
accessible by the operator.
Cable size: 1,5mm²
Switch
5mm
2
Panel
Rubber
Packing
Panel Cut-out
71,5mm
1
DIGITAL TIMER
184-253V AC 7
50/60Hz 5VA 8
Fuse
F 100 mA
250V AC
1241077
NOTE :
SUPPLY:
OUT1
OUT2
GATE
+12V
RESET
Holding screw
0.4-0.5Nm.
Flush mounting
clamp
Flush mounting
clamp
29,5mm
4
START
Equipment is protected throughout by
DOUBLE INSULATION
3
GATE
OUT2
+12V
START
GATE
RESET
OUT2
OUT1
OUT1
2
250V AC 8A RESISTIVE LOAD
1
11 12
11 12
10
10
9
9
8
8
230V AC +10% -20%
50/60Hz
7
7
6
6
5
STOP
5
4
START
24V AC/DC +10% -20%
50/60Hz
250V AC 8A RESISTIVE LOAD
60mm
- Push the flush-mounting clamp
in direction 1 as shown in the
figure below.Then, pull out the
clamp in direction 2 .
SET
SET
4
3
SN: XXXXXXXXX
3
230V AC +10% -20%
50/60Hz
1
35mm
1241078
MIN
M
HOUR
H
OUT2
For removing mounting clamps:
2
2
SN: XXXXXXXXX
Made In Turkey
250V AC 8A RESISTIVE LOAD
1
1
Depth
77mm
OUT1
OUT1
1241077
Suitable for flush-panel mounting according to DIN 43 700.
W77xH35xD71mm
Approx. 198g (After packing)
Self extinguishing plastics
1
124-1077
124-1078
Note: 1) Panel thickness should
be maximum 7mm.
2) If there is not 60mm free
space at the back side of
the device,it would be
difficult to remove it from
the panel.
1241077/78-E-01-161006
SET
OUT1
OUT1
OUT2
HOUR
H
OUT1 LED : Specifies the output OUT1.
MIN
M
START
OUT2 LED : Specifies the output OUT2.
SET
SET
STOP
HOUR LED : Selected time unit is HOUR.
MIN LED
: Selected time unit is MINUTE.
Timer value can be set in Running Mode , Parameter values can be set in Programming Mode and newly assigned parameter values can be saved .
SET
After parameter values are changed , new values are saved to memory and Running Mode is returned either by pressing
button or by waiting 10
seconds.
Timer is started by pressing
button for 1 second , when Str.2 is selected (Except,either parameter or time set value changing) .
Menu parameters can be accessed in Programming Mode. Parameter set values can be increased. Timer set value can be increased in Time Config
Mode. Timer set value increases gradually accelerated by pressing continuously.
Timer and audible warning are stopped by pressing button for 1 second. when Str.2 is selected (Except,either parameter or time set value changing) .
Menu parameters can be accessed in Programming mode. Parameter set values can be decreased. Timer set value can be decreased in Time Config
Mode. Timer set value decreases gradually accelerated by pressing continuously.
TIME CONFIG MODE
28 :00
Timer
set
value
SET
SET
27 :59
28 :00
28 :00
SET
SET
Running Mode switches to Time Config Mode by pressing
button. Display indicates configuration mode is opened by flashing. Desired timer set value can be set by pressing
SET
new timer set value is saved to memory and Running Mode is returned either by pressing
button or by waiting 10 seconds.
Programing Menu is opened and Confparameter is seen by pressing
sub-menu parameter is opened when pressing
button.
SET
and
buttons at same time. Switching between menu parameters is done by pressing
SET
SET
buttons. After desired timer value set,
button. While one of menu parameter is seen,
SET
In order to change sub-menu parameters value, press
buttons while holding button down.When
button is released , all changes will be saved to memory and related sub-menu parameter is returned.
Programming Menu is returned from sub-menu parameters by pressing
buttons at same time. In the sub-menu , all changes will be saved to memory and Running Mode is returned from sub-menu
SET
if no key is pressed for 10 seconds. In programming menu , all changes can be saved to memory and Running Mode can be returned from programming menu either by pressing
buttons at same time or
if no key is pressed for 10 seconds.
SET
Programming Menu
Parameter Configuration Diagram
SET
SET
SET
SET
Conf
tIME
5tr.t
0ut.t
5ond
p.5EC
t.5Et
Time unit ;
hour (hour) or
min (minute)
t.lol
If Str.t is Str.1, digital inputs
(start,reset,gate) are enabled.
If Str.t is Str.2,
START/STOP buttons are enabled.
t.upl
Output type ;
9 different output type
can be selected.
(Out.1, Out.2, Out.3, . . , Out.9 )
Detailed in page 3/4.
In.dE
time
Time config lower limit ;
can be selected between
0:01 and t.uPL parameter
value.
Time config upper limit ;
can be selected between
t.loL parameter value
and 99:59.
Time config increase/decrease
step;
can be selected between
1 and 30.
5.Cod
(dPArmessage is seen and
factory reset is started
if holding
button down for 4
seconds while S.Cod is 0.)
a. -t.5.
a. -t.c.
Audible Warning Config ;
8 different sound type
can be selected.
If sd. is 1,
audible warning is enabled.
FOR MORE INFORMATION VISIT THIS SITE
http://www.rs-components.com/index.html
Parameter security code ;
Parameter value must be
432.
2/4
hour
SET
min
hour
SET
In order to set related parameter to desired value , hold
button down,
when display is started to flash use
buttons.
Value increases/decreases gradually accelerated by pressing
buttons continuously.
t.SEt security parameter ;
nonE: Programming Menu
invisible.
P.YES: Programming Menu
parameter can be changed.
P.no : Programming Menu
parameter can only be seen.
ConF and tSEt security parameter ;
nonE: Programming Menu
invisible.
P.YES: Programming Menu
parameter can be changed.
P.no : Programming Menu
parameter can only be seen.
1241077/78-E-01-161006
1241077 & 1241078 DIGITAL TIMER OUTPUT TYPES
NOTE : Selected area indicates the moment of power-up, if the external "START" input is active.
START
STOP
RESET
OUT1
OUT2
POWER
When device is powered, If START input is set
OUT1 and OUT2 relays are turned on.
When timer set value is expired ,
OUT1 and OUT2 relays are turned off.
If RESET input is set before timer set value
expires OUT1 and OUT2 relays are turned off
and timer set value is renewed.
Out.6
Out.1
POWER
START
START
START
STOP
RESET
OUT1
OUT2
DISPLAY
DISPLAY
%100
%100
%0
START
STOP
RESET
OUT1
OUT2
DISPLAY
%100
%0
Out.3
POWER
START
START
STOP
RESET
OUT1
OUT2
DISPLAY
Out.7
START
POWER
When device is powered, If START input is set
OUT1 and OUT2 relays are turned on.
When timer set value is expired,
OUT1 and OUT2 relays are turned off.
If RESET input is set before timer set value
is expired OUT1 and OUT2 relays are turned off
and timer set value is renewed.
If START input is set before timer set value
is expired , relays remain turned-on and timer set
value is renewed and timer starts counting down.
START
START
STOP
RESET
OUT1
OUT2
DISPLAY
%100
%0
When device is powered , If START input is set
timer starts counting down.
When timer set value is expired,
OUT1 and OUT2 relays are turned on and
timer set value is renewed. If START input is
set again, OUT1 and OUT2 relays are turned off
and timer starts counting down.
İf RESET input is set OUT1 and OUT2 relays are
turned off and timer stops counting down.
POWER
Out.8
Out.2
POWER
%0
START
START
STOP
RESET
OUT1
OUT2
DISPLAY
%100
%100
%0
%0
START
START
STOP
RESET
OUT1
OUT2
When device is powered, If START input is set
OUT1 and OUT2 relays are turned on.
When timer set value is expired,
OUT1 and OUT2 relays are turned off , timer
set value is renewed and timer starts counting
down again.This process periodically continues.
If RESET input is set OUT1 and OUT2 relays are
turnef off and timer stops counting down.
POWER
Out.9
Out.4
POWER
START
START
STOP
RESET
OUT1
OUT2
DISPLAY
%100
%0
%0
START
START
STOP
RESET
OUT1
OUT2
DISPLAY
%100
%0
When device is powered, If START input is set
OUT1 and OUT2 relays are turned on.When START
input is reset timer starts to counting down.
When timer set value is expired,
OUT1 and OUT2 relays are turned off and
timer set value is renewed.
If START input is set while timer counts down,
timer set value is renewed. When START input is
reset timer starts to counting down.
If RESET input is set OUT1 and OUT2 relays are turned off
and timer stops counting down.
POWER
GATE USAGE
POWER
Out.5
DISPLAY
%100
3/4
START
START
STOP
RESET
GATE
When device is powered, If START input is set
OUT1 and OUT2 relays are turned on and timer starts
counting down.
If START input is reset , timer value is renewed to
timer set value and timer starts to counting down.
If START input is set again , timer value is renewed
to timer set value.When timer set value is expired,
OUT1 and OUT2 relays are turned off and timer
value is renewed to timer set value.
If RESET input is set,OUT1 and OUT2 relays are turned off
and timer value is renewed to timer set value.
When device is powered, If START input is set
OUT1 and OUT2 relays are turned on and timer starts
counting down from timer set value .When timer set value is
expired,OUT1 and OUT2 relays are turned off.If START input
is reset after an timer set value is expired,timer value is
renewed to timer set value.If START input is reset while
timer counts down ,OUT1 and OUT2 relays are turned off.
If RESET input is set while START input is set ,
OUT1 and OUT2 relays are turned off and
timer value is renewed to timer set value.If RESET input is
reset while START input is set , OUT1 and OUT2
relays are turned on and timer starts counting down
When device is powered, If START input is set
OUT1 relay is turned on and timer starts counting
down from timer set value.When timer set value is expired,
OUT2 relay is turned on.If START input is reset when
timer set value is expried, timer value is renewed to
timer set value . If START input is reset
while timer counts down OUT1 and OUT2 relays are turned off.
If RESET input is set while START input is set ,
OUT1 and OUT2 relays are turned off and timer value
is renewed to timer set value. If RESET input is reset
while START input is set , OUT1 relay is turned on and
timer starts counting down.
When device is powered, If START input is set ,
timer starts counting down. When timer set value is expired,
OUT1 and OUT2 relays are turned on.
If START input reset when timer set value is expired,
OUT1 and OUT2 relays are turned off and timer value is
renewed to timer set value.If START input is reset
while timer counts down , timer value is renewed to
timer set value.
If RESET input is set while START input is set , timer value is
renewed to timer set value.
If RESET input is reset while START input is set , timer value is
renewed to timer set value.and starts counting down.
When device is powered, If GATE input is set ,timer
set value is seen on display and timer stops counting down.
If GATE input is reset , timer continue where it remains.
If RESET input is set while GATE input is reset, OUT1
and OUT2 relays are turned off and timer value is
renewed to timer set value.
OUT1
OUT2
DISPLAY
%100
%0
1241077/78-E-01-161006
1241077 & 1241078 DIGITAL TIMER PARAMETERS
CONFIGURATION PARAMETERS
Parameter
Name
Functional Specification
Min.
Max.
timE
Device time config
00:01
99 :59
5tr.t
Device input control parameter
5tr.1
5tr.2
0ut.t
Device output control parameter
0ut.1
5ond
Device audible warning control parameter
5d.1
Factory
Settings
Unit
hr:min
min
min:sec.
5tr.1
Out.9
0ut.1
5d.8
5d.1
TIMER CONFIGURATION PARAMETERS
t.LoL
Time config lower limit define parameter
00 :01 99 :59
00:01
t.uPL
Time config upper limit define parameter
00 :02
99 :59
99 :59
in.dE
Time config increase/decrease coefficient parameter
0
9999
SECURITY PARAMETERS
5.Cod
Security code parameter
A.-t.5.
Time config security parameter
P.YE5
A.-t.c.
Menu security parameter
P.YE5
0
Note 1:
If 5tr.tselected 5tr.1, Control is provided with START - RESET - GATE inputs.
Note 2:
If 5tr.t selected 5tr.2 ,Control is provided with device front panel START ( ) - STOP ( ) buttons.
Note 3:
GATE input can be used for all 5tr.t and 0ut.t types.
Note 4:
When 5tr.t parameter switched from 5tr.1 to 5tr.2 , device continue to work with present 0ut.t output setting.
Timer can be stopped with device front panel STOP( ) button in case of need.
Note 5:
Cases in Note 4 also valid for 5tr.tparameter switched from 5tr.2 to 5tr.1,
digital RESET input can be used instead of STOP button.
Note 6:
SET
In Running Mode, if the
,
and
keys are pressed together, revision number appears on display.
(In order to show the revision number, 5tr.t parameter must be set to 5tr.1 in Conf menu).
FOR MORE INFORMATION VISIT THIS SITE
http://www.rs-components.com/index.html
4/4
1241077/78-E-01-161006