New Product NiMH “H” Type Batteries “H” Type Nickel Metal Hydride Battery September 2004 HHR60AAAH, HHR210AH, HHR370AH, HHR250SCH, HHR300CH Matsushita Battery Industrial Co., Ltd. Improved Low Rate Charge Characteristics at Higher Temperatures Model Number Nominal Voltage Size HHR60AAAH Discharge Capacity1 (mAh) Dimensions (mm) Average Minimum Diameter Height Approx. Weight (g) AAA 1.2 550 500 10.5 + 0/-0.7 44.5 + 0/-1.0 12 HHR210AH A 1.2 2050 1900 17.0 + 0/-0.7 50.0 + 0/-1.5 38 HHR370AH L-fat A (18670) 1.2 3700 3500 18.2 + 0/-0.7 67.0 + 0/-1.5 60 SC 1.2 2650 2500 23.0 + 0/-1.0 43.0 + 0/-1.5 55 C 1.2 3300 3100 25.8 + 0/-1.0 50.0 + 0/-1.5 80 HHR250SCH HHR300CH 1. 0.2It discharge capacity after charging at 0.1It for 16 hours. Panasonic introduces a new line of NiMH cells that are superior to standard NiMH products in applications with low-rate charge at high temperatures. Improvements were made in existing Panasonic NiMH cells to the negative plate alloy and, separator fiber density. A new electrolyte composition was achieved to improve performance. Superior long-life characteristics can be achieved when combined with appropriate intermittent charge control circuitry. The intermittent charge consumes 1/30th the electricity compared to trickle charge and more than doubles the expected life of the NiMH cells compared to NiCd cells that have been trickle charged. Features Applications • Higher capacity in a smaller size and lighter weight than other battery back-up solutions (Lead-Acid, NiCd) • Efficient Charging at high temperatures (up to 60°C) • 8-12 year expected life when used with the proper charge control circuitry • • • • • Network storage-cache memory back-up Uninterruptable power supply units (UPS) - (HHR250SCH) Emergency lights Communication base stations (Micro cell, Pico cell) Load leveling Examples of characteristics Charging Characteristics by Temperature (HType vs. Standard NiMH Cell) Cycle Life Characteristics H-Type vs. Valve Regulated Lead-Acid Batteries 120 Ni-MH Capacity Ratio (%) (100% = Nominal Capacity) Charging Efficiency (%) 100 80 HHR210AH ("H" Type Ni-MH) HHR210A (Standard Ni-MH) 60 40 Test Condition Charge: 0.1It x 15h Rest: 3h Discharge: 0.2It to 1.0V at 25˚C 20 100 80 60 VRLA 40 20 Discharge capacity charged at 25˚C is 100 0 20 Discharge depth of 50% 0 25 30 35 40 45 50 55 60 Ambient Temperature During Charging (˚C) 0 100 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 Charge/Discharge Cycles Cycle Life Characteristics (H-Type vs. Standard NiMH Cell) 120 Charging Efficiency (%) 100 80 HHR210AH ("H" Type Ni-MH) HHR210A (Standard Ni-MH) 60 Test Condition 40 (1) Charge: 0.1It x 16h Rest: 1h Discharge: 0.2It to 1.0V 20 0 (2) Charge: 0.25It x 3h10m Rest: 0h Discharge: 0.25It x 2h20m 0 200 400 600 800 1000 1200 1400 Cycles NiMH “H” Series Recommended Charge System for back-up power applications (Applies to HHR60AAAH, HHR210AH, HHR370AH, HHR250SCH & HHR300CH Cylindrical cells) The optimal charge system for the NiMH “H” Series for back-up power applications is an intermittent timer charge. An intermittent timer charge improves charge efficiency, extends battery life (-vs- trickle charge) and reduces electricity consumption up to 30% compared to *trickle charge. Intermittent Timer Charge: (see diagram) At the beginning of the charge, an IC timer is started and charging is activated at a current of 0.1It until the timer stops and the charge is terminated. When the batteries self discharge down to a set point (1.3V), the timer charge is re-activated. *Trickle charge is not recommended for NiMH batteries. Please consult Panasonic on any NiMH applications requiring trickle charge. • Example of intermittent timer charger system: Average Charge Current: 0.1ItA Re-charge Time: 16 hours Pulse charging can be used Intermittent Charge VB VB 0 [h] This literature contains information concerning cells and batteries manufactured by Matsushita Battery Industrial Co., Ltd. This information is generally descriptive only and is not intended to make or imply any representation guarantee or warranty with respect to any cells and batteries. Cell and battery designs are subject to modification without notice. Contact Panasonic for safety precautions and the latest specifications before purchase and/or use. 2004 Copyright Matsushita Battery Industrial Co., Ltd. All rights reserved. Panasonic Industrial Company A Division of Matsushita Electric Corporation of America Toll Free: 877-726-2228 E-mail: [email protected] Web: www.panasonic.com/batteries NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET HHR60AAAH Cylindrical AAA size (HR 11/45) Dimensions (with Tube) Typical Charge Characteristics (mm) 2.0 Charge: 0.5 It(265mA) x 2.4h at 20, 45, 65˚C Rest: 1-3h 1.8 Voltage (V) 10.5 +- 00.7 (+) 1.6 1.4 1.2 20˚C 45˚C 60˚C 1.0 0.8 0 100 200 300 +0 1.0 44.5 - 400 500 600 700 800 900 1000 Capacity (mAh) Typical Discharge Characteristics ( ) 2.0 Charge: 1/3 It(177mA) x 3.8h at 20˚C Rest: 1h Discharge: 0.2It(106mA), 1It(530mA), 2It(1060mA) to 1.0V at 20˚C 1.8 mm inch Diameter 10.5 +0/-0.7 0.41 +0/-0.03 Height 44.5 +0/-1.0 1.75 +0/-0.04 Approximate Weight Grams Ounces 12 0.42 Voltage (V) Specifications 1.6 1.4 1.2 0.2It 1It 2It 1.0 0.8 Nominal Voltage Average2 Discharge Rated (Min.) Capacity1 Approx. Internal impedance at 1000Hz at charged state. Standard Rapid3 Charge Ambient Temperature Low Rate Charge Standard Rapid Discharge < 1 year < 6 months Storage < 1 month < 1 week 1.2V 550 mAh 500 mAh 0 100 200 300 400 500 600 700 800 900 1000 Capacity (mAh) 35mΩ 50mA x 16hrs. 250mA x 2.4 hrs.4 25mA x 32 hrs. 17mA x 48 hrs. ˚C ˚F 14˚F to 140˚F -10˚C to 60˚C 14˚F to 113˚F -10˚C to 45˚C -10˚C to 60˚C 14˚F to 140˚F -4˚F to 95˚F -20˚C to 35˚C -4˚F to 113˚F -20˚C to 45˚C -4˚F to 131˚F -20˚C to 55˚C -4˚F to 149˚F -20˚C to 65˚C 1 After charging at 0.1It for 16 hours, discharging at 0.2It. 2 For reference only. 3 Need specially designed control system Control System: dT/dt cut-off; 1 to 2°C/min -UV cut-off; -UV per cell = 5 to 10 mV T-control; T=65°C Rapid charger timer; 2.4h (at 1.25a) Trickle timer; within 2h 4 With control system Battery performance and cycle life are strongly affected by how they are used. In order to maximize battery safety, please consult Panasonic when determining charge / discharge specs, warning label contents and unit design. Note: [It] was previously expressed as [C]. [It] is an IEC standard expression for the amount of charge or discharge current and is expressed as: It(A) = Cn (Ah)/1h * [It] is the reference test current in ampres * [Cn] is the rated capacity of the cell or battery in Ampere-hours. n = the time base [hours] for which the rated capacity is declared NICKEL METAL HYDRIDE HANDBOOK SEPTEMBER 2004 This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification without notice. Contact Panasonic for the latest information. NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET Typical Charge Characteristics HHR210AH Cylindrical A size (HR 17/50) Dimensions (with Tube) (mm) 2.0 1.9 Charge:210mA(0.1 It)✕16hrs. 1.8 Voltage (V) 1.7 1.6 1.5 1.4 1.3 1.2 1.1 +0 0.7 17.0 - -10˚C 25˚C 60˚C 1.0 (+) 0.9 0.8 0 2 4 6 8 10 12 14 16 18 20 Charge Time (hours) Typical Discharge Characteristics 50.0 +- 01.5 120 Capacity Ratio (%) 110 ( ) Specifications 100 90 80 70 60 50 40 Diameter mm inch 17.0+0/-0.7 0.67+0/-0.03 Height 50.0+0/-1.5 1.97+0/-0.06 Approximate Weight Grams Ounces 38 1.34 2.0 1.9 1.8 Rated (Min.) 1900mAh 1.7 1.6 Ambient Temperature Charge Standard 210mA (0.1It) x 16 hrs. ˚C ˚F -10˚C to 60˚C 14˚F to 140˚F - - -10˚C to 60˚C 14˚F to 140˚F < 1 year -20˚C to 35˚C -4˚F to 95˚F < 3 months -20˚C to 45˚C -4˚F to 113˚F < 1 month -20˚C to 55˚C -4˚F to 131˚F < 1 week -20˚C to 60˚C -4˚F to 140˚F Rapid Discharge Storage 20mΩ Voltage (V) 1.2V 2050mAh Approx. internal Impedance at 1000Hz at charged state. Standard Charge Rapid - 10 0 10 20 30 40 50 60 70 Temperature (˚C) Average2 Nominal Voltage Discharge Capacity1 30 - 20 Charge: 210mA(0.1 It)✕15hrs Disharge: 420mA(0.2 It),cut off voltage 1.0V Disharge Temperature: 25˚C Charge: 210mA(0.1 It)✕16hrs,25˚C Disharge: 420mA(0.2 It) 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0 0˚C 25˚C 60˚C 1 2 3 4 5 6 Charge Time (hours) 1 After charging at 0.1It for 16 hours, discharging at 0.2It. 2 For reference only. Battery performance and cycle life are strongly affected by how they are used. In order to maximize battery safety, please consult Panasonic when determining charge / discharge specs, warning label contents and unit design. Note: [It] was previously expressed as [C]. [It] is an IEC standard expression for the amount of charge or discharge current and is expressed as: It(A) = Cn (Ah)/1h. • [It] is the reference test current in ampres • [Cn] is the rated capacity of the cell or battery in Ampere-hours. n = the time base [hours] for which the rated capacity is declared NICKEL METAL HYDRIDE HANDBOOK SEPTEMBER 2004 This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification without notice. Contact Panasonic for the latest information. NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET HHR370AH Cylindrical L-Fat A size (HR 18/67) (mm) 2.0 1.9 Voltage (V) Dimensions (with Tube) Typical Charge Characteristics 18.2 +- 00.7 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0 (+) Charge: 330mA(0.1 It)✕16hrs. -10˚C 25˚C 60˚C 2 4 6 8 10 12 14 16 18 20 Charge Time (hours) Typical Discharge Characteristics 67.0 +- 01.5 120 Capacity Ratio (%) 110 ( ) 80 70 60 40 Nominal Voltage Average2 Discharge Rated (Min.) Capacity1 Approx. Internal impedance at 1000Hz at charged state. Standard Rapid3 Charge Low Rate Standard Rapid Discharge < 1 year < 6 months Storage < 1 month < 1 week mm 18.2+0/-0.7 inch 0.72+0/-0.03 67.0+0/-1.5 Grams 2.64+0/-0.06 Ounces 60 2.12 30 - 20 Charge: 330mA(0.1 It)✕15hrs Disharge: 660mA(0.2 It),cut off voltage 1.0V Disharge Temperature: 20˚C - 10 0 10 20 30 40 50 60 70 Temperature (˚C) 2.0 1.2V 3700 mAh 3500 mAh Charge: 330mA(0.1 It)✕16hrs,25˚C Disharge: 660mA(0.2 It) 1.9 1.8 20mΩ Voltage (V) Diameter Height Approximate Weight Ambient Temperature 90 50 Specifications Charge 100 370mA x 16hrs. 1750mA x 2.4 hrs.4 185mA x 32 hrs. 123mA x 48 hrs. ˚F ˚C 14˚F to 140˚F -10˚C to 60˚C 14˚F to 113˚F -10˚C to 45˚C -10˚C to 60˚C 14˚F to 140˚F -4˚F to 95˚F -20˚C to 35˚C -4˚F to 113˚F -20˚C to 45˚C -4˚F to 131˚F -20˚C to 55˚C -4˚F to 149˚F -20˚C to 65˚C 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 0 0˚C 25˚C 60˚C 1 2 3 4 5 6 Charge Time (hours) 1 After charging at 0.1It for 16 hours, discharging at 0.2It. 2 For reference only. 3 Need specially designed control system Control System: dT/dt cut-off; 1 to 2°C/min -UV cut-off; -UV per cell = 5 to 10 mV T-control; T=65°C Rapid charger timer; 2.4h (at 1.25a) Trickle timer; within 2h Note: 4 With control system Battery performance and cycle life are strongly affected by how they are used. In order to maximize battery safety, please consult Panasonic when determining charge / discharge specs, warning label contents and unit design. [It] was previously expressed as [C]. [It] is an IEC standard expression for the amount of charge or discharge current and is expressed as: It(A) = Cn (Ah)/1h. • [It] is the reference test current in ampres • [Cn] is the rated capacity of the cell or battery in Ampere-hours. n = the time base [hours] for which the rated capacity is declared NICKEL METAL HYDRIDE HANDBOOK SEPTEMBER 2004 This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification without notice. Contact Panasonic for the latest information. NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET Typical Charge Characteristics HHR250SCH Cylindrical SC size (HR 23/43) Dimensions (with Tube) (mm) 2.0 Charge: 0.1It x 15h at 25, 40, 60˚C Discharge: 0.1It to 1.0V at 25˚C Voltage (V) 1.8 23.0 +- 01.0 1.6 1.4 1.2 25˚C 40˚C 60˚C 1.0 (+) Rest: 3h 0.8 0 500 1000 1500 2000 2500 3000 3500 4000 4500 Capacity (mAh) 43.0 +- 01.5 Typical Discharge Characteristics 2.0 Charge: 0.5It x 2.4h at 25˚C Rest: 1h Discharge: 1, 2, 3It to 0.8V at 25˚C Voltage (V) 1.8 ( ) Specifications 1.4 1.2 mm inch Diameter 23.0+0/-1.0 0.91+0/-0.04 1.0 Height 43.0+0/-1.5 1.69+0/-0.06 0.8 Approximate Weight Grams Ounces Low Rate Charge Standard Rapid Discharge < 1 year < 6 months Storage < 1 month < 1 week 55 1It 2It 3It 0 500 1000 1500 2000 2500 3000 3500 4000 4500 Capacity (mAh) 1.94 1.2V 2650 mAh 2500 mAh 5mΩ 1.6 250mA x 16hrs. 1250mA x 2.4 hrs.4 125mA x 32 hrs. 83mA x 48 hrs. ˚F ˚C 14˚F to 140˚F -10˚C to 60˚C 14˚F to 113˚F -10˚C to 45˚C -10˚C to 60˚C 14˚F to 140˚F -4˚F to 95˚F -20˚C to 35˚C -4˚F to 113˚F -20˚C to 45˚C -4˚F to 131˚F -20˚C to 55˚C -4˚F to 149˚F -20˚C to 65˚C Charge: 0.5It x 2.4h Rest: 1h Discharge: 10, 20, 30A to 0.8V at 20˚C 1.5 1.4 Voltage (V) Nominal Voltage Average2 Discharge Rated (Min.) Capacity1 Approx. Internal impedance at 1000Hz at charged state. Standard Rapid3 Charge Ambient Temperature 1.6 1.3 1.2 10A 1.1 20A 30A 1.0 0.9 0.8 0.7 0.6 0 500 1000 1500 2000 2500 3000 Capacity (mAh) 1 After charging at 0.1It for 16 hours, discharging at 0.2It. 2 For reference only. 3 Need specially designed control system Control System: dT/dt cut-off; 1 to 2°C/min -UV cut-off; -UV per cell = 5 to 10 mV T-control; T=65°C Rapid charger timer; 2.4h (at 1.25a) Trickle timer; within 2h 4 With control system Battery performance and cycle life are strongly affected by how they are used. In order to maximize battery safety, please consult Panasonic when determining charge / discharge specs, warning label contents and unit design. Note: [It] was previously expressed as [C]. [It] is an IEC standard expression for the amount of charge or discharge current and is expressed as: It(A) = Cn (Ah)/1h * [It] is the reference test current in ampres * [Cn] is the rated capacity of the cell or battery in Ampere-hours. n = the time base [hours] for which the rated capacity is declared NICKEL METAL HYDRIDE HANDBOOK SEPTEMBER 2004 This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification without notice. Contact Panasonic for the latest information. NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET HHR300CH Cylindrical C size (HR 26/50) for backup use Dimensions (with Tube) Typical Charge Characteristics (mm) 2.0 Charge: 300mA(0.1 It) x 16hrs. Voltage (V) 1.8 1.6 1.4 1.2 25.8 +- 01.0 10˚C 25˚C 60˚C 1.0 (+) 0.8 0 2 4 6 8 10 20 30 40 50 60 60 70 Charge Time (hours) 50.0 +- 01.5 120 Capacity Ratio (%) 110 ( ) Specifications Diameter 25.8+0/-1.0 Height 50.0+0/-1.5 Ounces 80 2.82 Charge 3300 mAh Rated (Min.) 3100 mAh Ambient Temperature Charge 155mA x 32 hrs. 100mA x 48 hrs. 1 2 < 1 year < 3 months < 1 month Charge: 300mA (0.1 It) x 16 hrs. Charge Temperature: -10 to 60˚C Discharge: 600mA (0.2 It) Cut-off Voltage: 1.0V Discharge Temperature: 25˚C -10 0 10 20 30 40 50 Charge: 300mA(0.1It) x 16 hrs., 25°C Discharge: 10A, 20A, 25°C 1.6 300mA (0.1It) x 16hrs. Low Rate Discharge Storage 5mΩ 1500mA (1It) x 2.4 hrs.4 Rapid Low Rate 50 1.8 Standard Rapid3 Standard 60 Typical Discharge Characteristics 1.2V Average2 Approx. Internal impedance at 1000Hz at charged state. 70 Temperature (°C) ˚C ˚F 0˚C to 45˚C 10˚C to 40˚C -10˚C to 45˚C -10˚C to 65˚C 32˚F to 113˚F 32˚F to 104˚F 14˚F to 149˚F 14˚F to 113˚F -20˚C to 35˚C -20˚C to 35˚C -20˚C to 55˚C -4˚F to 95˚F -4˚F to 95˚F -4˚F to 131˚F Voltage (V) Discharge Capacity1 80 30 -20 Grams Nominal Voltage 90 40 mm Approximate Weight 100 1.4 1.2 1.0 10A 20A 0.8 0 5 10 15 20 25 30 Discharge Time (minutes) After charging at 0.1It for 16 hours, discharging at 0.2It. For reference only. 3 Need specially designed control system Control System: dT/dt cut-off; 1 to 2°C/min -UV cut-off; -UV per cell = 5 to 10 mV T-control; T=65°C Rapid charger timer; 2.4h (at 1.25a) Trickle timer; within 2h 4 With control system Battery performance and cycle life are strongly affected by how they are used. In order to maximize battery safety, please consult Panasonic when determining charge / discharge specs, warning label contents and unit design. Note: [It] was previously expressed as [C]. [It] is an IEC standard expression for the amount of charge or discharge current and is expressed as: It(A) = Cn (Ah)/1h. • [It] is the reference test current in ampres • [Cn] is the rated capacity of the cell or battery in Ampere-hours. n = the time base [hours] for which the rated capacity is declared NICKEL METAL HYDRIDE HANDBOOK SEPTEMBER 2004 This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification without notice. Contact Panasonic for the latest information.
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement