FEATURES

● Full-featured console suitable for office environments or dispatch centers

● Accommodates up to 12 channels with a mix of control types: DC remote, tone remote, local control, E&M control

● Fully field programmable with "Any Button, Any

Function":

Individual volume adjustment, mute, and instant transmit per channel

Simul-Select, All-Mute, Alerts, and Site

Intercom

• Built-in encoder with optional single button paging steers tones to proper channel and frequency

• Channel-to-channel patch and optional phone patch

● Interfaces with outside phone line or analog PBX port - ideal for phone patches or administrative calls

● Optional Telephone/Radio Headset Interface allows one common headset to operate both radio console and separate telephone set

● Optional ANI decode/display shows unit identification of calling units

● MDC-1200 Signaling. ANI and Emergency Alert/

Acknowlege features

OVERVIEW

The Zetron Model 4010 Dispatch Console is a selfcontained, multichannel, radio control console which is available in both desktop or rackmount styles. It provides dispatchers with an efficient means of monitoring and dispatching for a system comprised of up to twelve radio channels. The M4010 presents the operator with both aural and visual cues to simplify the task of supervising a multichannel communications system.

The Model 4010 Dispatch Console offers a costeffective high-performance solution for a wide range of public safety, utility, and private land mobile radio applications. It is specifically designed for police, fire,

EMS, railroad, and plant security operations. Attractive enough for office environments, the Model 4010 is rugged enough for sustained, "24/7" communications center use.

The Model 4010 can be configured with as few as two channels and grow to twelve channels with the addition of modular channel cards. Channel cards may be specified to be compatible with all common local and remote control standards. The rackmount 4010 may be equipped with an optional 60 button expansion panel (if required).

OPERATION

The Model 4010 has been designed to simplify the task of operating a multichannel system, allowing operators to concentrate on the content of their dispatching activities.

MultiFunction LCD — The backlit, wide viewing angle

LCD serves several purposes. It normally shows the time and the audio level. During paging, it indicates the pager code being sent. In the event of a self-diagnosed problem, the display spells out the problem in plain

English. ANI codes may be displayed as well.

Buttons — Button functions are clearly labeled and color coded on the key’s surface to provide easy function association. All primary functions are performed by a single keystroke.

Indicators — The indicators for the button’s function are located next to the button for clear association. For dual functions, the adjacent LED indicators use different colors to ensure positive identification. The wide viewing angle ensures excellent visibility even across the room.

Select/Unselect Speakers — Two speakers provide a left/right audio effect, making it easy to distinguish whether the call was from the primary (Selected) channel or some other channel. Selecting a channel moves its monitor audio to the Select speaker.

Individual Channel Volume/Mute — The volume on each channel may be set independently, allowing the operator to prioritize listening based on volume. The LCD display shows volume percentage, allowing accurate settings. Single button muting instantly reduces the volume of a channel to a predetermined level.

Call — When channel activity is present, the channel's

"CALL" indicator blinks, making it easy to locate the source of the call. The call indication remains for a few seconds after the call stops in the event the operator is busy with another activity.

Patch — The simplex, VOX operated patch can patch together channels-to-channels or channels-to-telephone lines. The operator may monitor the patch and operate on other channels.

Transmit — The operator may transmit over the selected channel(s) by pressing the “Transmit” button or by pressing the optional foot-operated transmit switch.

With “Instant Transmit”, the operator may transmit over a non-selected channel to reply to a call without changing channel selection.

Monitor — This allows the operator to disable coded squelch on the selected channel so the channel may be monitored for traffic prior to transmitting.

Alert — Up to four different alert tones may be transmitted to indicate the type or priority of the dispatch to follow.

Auxiliary Input/Output — Operators may control various contact-closure operated devices (such as lights, door locks, and voter controls) from the console. External inputs (such as voter displays and alarms) may be monitored at the console.

Instant Call Paging — The operator may “tone out” an entire sequence of pages with the press of a single

Instant Call button. Paging sequences are automatically routed to the proper channel and frequency, eliminating potential human errors. Paging sequences may contain self-initiating alert tones for indicating specific types of events. The button's indicators provide a “check list” to verify that the proper pages were sent. Multiformat capability eliminates the need to have a different encoder for each type of pager/decoder.

PROGRAMMING

One of the unique features of the Model 4010 system is that it is FULLY field programmable with the Console

Programming System (CPS) and an IBM-compatible personal computer. CPS not only allows channels to be configured for various types of base stations, but it also allows any button to be assigned any available function.

This eliminates costly upgrades while allowing the buttons to be reconfigured at any time to accommodate new operating procedures or radio system changes. Key top labels are removable and do not require engraving, allowing the keys to be relabeled as easily as they are programmed. Standard key top legends are supplied by

Zetron while custom legends may be created in the field using transparent key tops.

Zetron Model 4010 Console Programming System

Select [E] Read Write Drive New Edit List Upload Program ? Help

KEY DEFINITION

Key Number 12

Channel Mute / Adjust for next channel key pressed

[D] Define Erase Move Copy Spare

[X]

[X]

[X]

[X]

[X]

[X]

[X]

[X]

[X]

[X]

[X]

[X]

[X]

[X]

[X]

[X]

[X]

[X]

[ ]

[ ]

[ ]

[ ]

[ ]

[ ]

[X]

[ ]

[ ]

[ ]

[ ]

[ ]

[ ]

[ ]

[ ]

[ ]

[ ]

[ ]

SYSTEM FUNCTIONS

A. Transmit Keys

B. Monitor

C. Site Intercom

D. Alert

E. Mute Keys

F. Simultaneous Select

G.Group Keys

H. Priority Marker

I. Speaker/Headset

J. Diagnostics Reset

K. Clock Set

L. ANI Keys

M. Channel Test

N. Phone Keys

O.Paging Keys

P. Burst Tone Select Key

Selection [E]

The console is shipped from the factory programmed and labeled to customer specifications, with a diskette containing the Console Programming System and the factory programming files. CPS runs under DOS with a minimum of 512K of memory, a 3.5" disk drive, and an

RS-232 serial port.

Changing the function of a key is simply a matter of using the cursor to select a new function from a menustyle list on the computer screen. When all selections are made, the new configuration is saved on the diskette and printed out for a paper copy. When ready, the stored configuration may be downloaded to the console in a matter of seconds. Configurations can also be uploaded from a console to a PC for storage or modification.

INSTALLATION AND MAINTENANCE

The Model 4010 is fully self-contained requiring no external electronics. It uses industry standard 25-pair cables and punchdown blocks for interfacing to radios and leased lines. Standard or lightning-protected connectorized punchdown blocks are available. External options, such as desk-mic and headset jack are also connectorized. All line adjustments, status LEDs and configuration switches are accessible through the rear panel without any disassembly.

The Console operates from 12 Volts DC, which is available from Zetron’s universal power-supply that accepts any voltage from 95 to 250 VAC at 47 to 440 Hz.

The universal power-supply has UL, CSA and VDE approvals.

The “clam-shell” design of the desktop Model 4010 and the easily-removed back and top of the rackmount model make access for maintenance and upgrades easy. All channel electronics are contained on plug-in circuit cards for easy replacement or expansion. Audio throughout the console remains analog and is not digitized. In addition to providing superior audio fidelity, this makes audio troubleshooting easier. The service manual contains full schematics, parts IDs, parts lists and theory of operation.

Factory service, spare boards, and spare parts kits are available.

OPTIONS

The wide variety of options available for the Model 4010 allow it to be tailored to any dispatch environment.

MDC-1200 Signaling — Allows for an ID code to be transmitted every time a radio is keyed, providing useridentification for each radio. ID transmission may be programmed to occur at the beginning or end of transmission, or both. When combined with emergency alert/acknowledge signaling, mobile and portable radios equipped with MDC-1200 protocol can transmit an emergency ANI signal with the press of a button to request immediate help. MDC-1200 signaling provides an efficient way for the dispatcher to receive the identification information, send an acknowledgment back to the radio, and respond to the emergency.

Gooseneck Microphone — The unidirectional 12-inch gooseneck mounts directly to the Model 4010.

Desk Microphone — The omnidirectional dynamic desk microphone has its own transmit and monitor bars.

Handset and Cradle — When the PTT handset is in the console mounted cradle, the console’s “select” speaker is live. When the handset is lifted, the “select” audio reverts to the handset earpiece.

Headset Jack — The headset jackbox may be mounted to the side of the console or under a desk writing surface. When a headset is not plugged into the jack, the console’s “select” speaker is live; when it is plugged in, the “select” audio reverts to the headset earpiece.

Telephone Radio Headset Interface — The telephone radio headset interface allows one common headset to be used for both radio and telephone, with a volume control for each. When the telephone set indicates that it is connected to a line (off- hook), the common headset is switched to the telephone and the console’s “select” speaker becomes live. If the operator transmits on the console, the headset is momentarily switched back to the radio console. When the telephone is disconnected from the line, the headset reverts back to the console and the console’s “select” speaker becomes muted.

Requires off-hook contact closure from telephone.

Footswitch — Footswitches are available for controlling selected channel transmit and monitor, allowing handsfree operation.

Automatic Number Identification (ANI) — ANI codes generated by mobile or portable radios are shown on the console's LCD display, when M4010 is equipped with an

ANI decoder.

Phone Patch — The phone patch option allows the console operator to establish a patch between any radio channel and a telephone line. This option also allows the operator to originate and answer telephone calls using the console.

Paging Formats — The built-in paging encoder is capable of generating all popular signaling formats. The two most popular, Motorola/GE two-tone, and DTMF are standard. Optional formats include 1500 Hz or 2805 Hz rotary dial, Plectron, Quick-Call I (2+2), and 5/6 Tone.

Expansion Panel — The Model 4115 Console Expander provides 60 extra programmable keys for controlling radio channels and instant call paging functions. With the

Expansion Panel installed, the Model 4010R features 136 programmable keys.

SPECIFICATIONS

TRANSMIT ELECTRICAL SPECIFICATIONS

Audio Output +10dBm max. into 600 ohm line

Output Impedance Transmit: 600 ohm balanced.

Idle: 600 or 3500 ohms

Distortion

Microphone Input

<2% at full output. Hum, Cross-Talk all -50 dB at full output

-65 dBm for full output

Aux. Mic Input

Page/Spare Input

Frequency Response

Compression

-20 dBm for full output

-15 dBm, not compressed

-3 to +1dB from 250-5000 Hz except guard tone notch

Input level increase of 30 dB above knee of compression causes <3 dB output increase

RECEIVE ELECTRICAL SPECIFICATIONS

Input Impedance 600 or 10K ohm (4-wire)

Line Balance

Rx Sensitivity

Frequency Response

Compression

3500 ohm (2-wire)

66 dB at 1000 Hz

-30 dBm max. at knee of compression; adjustable

-3 to 1 dB from 250-5000 Hz except guard tone notch

Input level increase of 30 dB above knee of compression causes <3 dB output increase

Distortion

Call Light

Audio Outputs

Mute

<2%

Sensitivity 20 dB below knee of compression

5 watts into 4 ohms

Programmable from 0 to -28 dB or full mute

“All-mute” time programmable

PHYSICAL SPECIFICATIONS

Size: Desktop 9" high x 18" wide x 14" deep

Rackmount

Weight

Dust/Liquid Ingress

Operating Temp

10.5" high x 19" w x 10.5" deep

15 lbs.

NEMA 1, IEC 60529 IP 30

5 to 50 degrees Celsius

OTHER ELECTRICAL SPECIFICATIONS

Channel Interface Tx/Rx Audio pair (for 2w/4w

Rx Audio pair (for 4w)

PTT relay contact

Busy out

Busy in / X-Mute in

Channel Control

Local Control

E & M Control

Tone Control

DC Control

Busy Chan. Detect

Power Input

Aux Output

Aux Inputs

Supv control / main-stby

Recorder Out

Local, E & M, Tone Remote, DC Remote,

Telephone (tip/ring)

PTT normally open relay contact rated

1.0 A at 24 VAC/DC

Tx control via PTT relay, external 48V required

15 standard tones supported, programmable (no trimmer adjustment)

650-2050 Hz. High Level Guard Tone duration 120-600 msec. Function Tone

Duration 40 msec. Guard Tone Freq.

2175 Hz, alterable. Tone freq. accuracy

+/-0.2%; timing accuracy +/-1.0 %

Programmable for +/-2.5, 5.5, 6.0, 11, 12.5, and 15.5 mA. Operable up to 8K ohm loop resistance

Accuracy +/-.25mA

Local Cross-Busy detection; Guard Tone or

DC Control detection (LOTL) optional

11.5 to 15 VDC, 3.5A max or

95 to 250 VAC, 47 to 440 Hz

64 watts max

4-Form C contacts rated

0.5 Ampere

4-Open collector outputs rated

0.25 Ampere

8-TTL inputs (0-5 VDC)

For more information on this and other Zetron products, contact:

ZETRON USA

PO Box 97004

Redmond, WA

98073-9704

USA

TEL

FAX

425 820 6363

425 820 7031 [email protected]

WWW.ZETRON.COM

ZETRON UK

27-29 Campbell Court

Bramley TADLEY

Basingstoke RG26 5EG

UK

TEL

FAX

+44 (0)1256 880663

+44 (0)1256 880491 [email protected]

ZETRON AUSTRALASIA

PO Box 3045

Stafford Mail Centre

Stafford QLD 4053

Australia

TEL +61 7 3856 4888

FAX +61 7 3356 6877 [email protected]

All trademarks and registered trademarks are the property of their respective owners.

See Zetron price list for option pricing. Specifications subject to change without notice 005-0447M February 2005

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement