REED SD 4023 Sound Level Meter Instruction Manual

REED SD 4023 Sound Level Meter Instruction Manual

Below you will find brief information for Sound Level Meter SD 4023. The Sound Level Meter SD 4023 is a powerful and versatile tool for measuring sound levels in accordance with IEC61672 Class 2 specifications. It features A/C frequency weighting, fast/slow time weighting, Peak hold, Data hold and Max/Min record functions. The SD 4023 also boasts a real-time data logger with integral 4GB SD memory card, which can be used to record sound levels over time. The data can be easily downloaded to a computer in EXCEL format for analysis. The Sound Level Meter SD 4023 is ideal for a wide range of applications, including noise monitoring, occupational health and safety, product testing, and environmental assessments.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

REED Sound Level Meter SD 4023 Instruction Manual | Manualzz

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Blue - 100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Blue - 100/80/30/5

Rich Black -

20/20/20/100

Model

SD-4023

Sound Level Meter/

Data logger

Only if you REALLY need them:

Instruction

Manual

reedinstruments

www.reedinstruments.com

www

1-877-849-2127 | [email protected]

INSTRUMENTS

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Table of Contents

Features ......................................................................................... 3

Specifications .............................................................................4-5

Instrument Description .................................................................. 6

Operating Instructions ..............................................................7-11

Function Selection ...................................................................... 7

Data Hold ................................................................................... 7

Data Record (Max., Min. reading) ................................................ 8

Backlight ON/OFF ....................................................................... 8

Datalogger ...............................................................................8-9

Auto Datalogger .......................................................................... 9

Manual Datalogger .................................................................9-10

Checking the Time .................................................................... 10

Check Sampling Time Information ............................................. 10

SD Card Data Structure ............................................................ 10

Data Transfer from SD card to Computer .................................. 11

Advanced Settings .................................................................11-13

PC Serial Interface ....................................................................... 14

System Reset .............................................................................. 15

Battery Replacement ................................................................... 15

Blue - 100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0 reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

INSTRUMENTS

2

Features

• Measures sound levels in accordance with IEC61672 Class 2 specifications

• A/C frequency weighting

• Fast/Slow time weighting

• Peak hold, Data hold and Max/Min record

• Easy to read LCD with backlight

• Real time data logger with integral 4GB SD memory card

(OPTIONAL)

• Just plug the SD card into the computer and it downloads directly to

EXCEL

• RS232 and USB computer interface

• Easy to read LCD with backlight

• Auto or manual power off

• Includes Batteries

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Blue - 100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0 reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

INSTRUMENTS

3

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Specifications

Measuring Range:

Resolution:

Accuracy:

Frequency Weighting:

Time Weighting:

Frequency Range:

Auto Sampling Time:

Memory Card:

Data Output:

AC Output:

Output Impedance:

Power Supply:

Dimensions:

Weight:

Optional Accessories:

Blue - 100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Pantone 534 Blue

Black

30 to 130 dB

0.1 dB

31.5Hz ± 3.5 dB; 63 Hz ± 2.5 dB;

125 Hz ± 2.0 dB; 250 Hz ± 1.9 dB;

500 Hz ± 1.9 dB; 1 kHz ± 1.4 dB;

2 kHz ± 2.6 dB; 4 kHz ± 3.6 dB;

8 kHz ± 5.6 dB

A: Human Ear Listening; C: FLAT Response

Fast: 200ms; Slow: 500ms

31.5 to 8,000Hz

1, 2, 5, 10, 30, 60, 120, 300, 600, 1800,

3600 seconds

SD memory card, 1 GB to 16 GB

USB/RS232 PC computer interface

0.5Vrms corresponding to each range step

600Ω

6 x 1.5V UM3/AA batteries

Meter: 245 x 68 x 45mm (9.65 x 2.68 x 1.77”);

Microphone: 12.7mm (0.5”) dia.

489g (1.08 lb)

4G SD Card (SD-4GB)

Sound calibrator (R8090)

Wind shield ball (SB-01)

USB cable (USB-01)

Power adapter (AP-9VA-110V)

Data Acquisition Software (SW-U801-WIN)

Soft carrying case (CA-05A)

Tripod (BS-6) reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

continued...

4

INSTRUMENTS

Frequency Hz

31.5

63

125

250

500

1K

2K

4K

8K

A Weighting

-39.4 dB

-26.2 dB

-16.1 dB

-8.6 dB

-3.2 dB

0 dB

1.2 dB

1 dB

-1.1 dB

C Weighting

-3 dB

-0.8 dB

-0.2 dB

0 dB

0 dB

0 dB

-0.2 dB

-0.8 dB

-3 dB

Fast Time Weighting Max Response: -1.0 dB

Fast Time Weighting Tolerance: +1 dB/ -2 dB

Slow Time Weighting Max Response: -4.1 dB

Slow Time Weighting Tolerance: ±2 dB

Tolerance

±3.5 dB

±2.5 dB

±2.0 dB

±1.9 dB

±1.9 dB

±1.4 dB

±2.6 dB

±3.6 dB

±5.6 dB

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Pantone 534 Blue

Pantone 123 Yellow

Blue - 100/80/30/5

Yellow - 0/27/100/0

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Red - 10/100/100/5

For service on this or any other REED product or information on other

REED products, contact REED Instruments at [email protected]

Black reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

5

INSTRUMENTS

Instrument Description

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

1. Display

2. Power, ESC, & Backlight Button

3. Hold & Next Button

4. REC & Enter Button

5. Range, Up, & Time Check

Button

6. A/C, Down, & Sampling Time

Check Button

Yellow - 0/27/100/0

Yellow - 0/27/100/0

9. Microphone

10. AC Output

11. Calibration VR

12. USB/RS232 Output

13. AC/DC 9V Power Adapter Input

Socket

14. Tripod Fix Nut

15. Battery Cover Screws

16. Stand

17. Battery compartment/Cover

18. SD card slot reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

6

INSTRUMENTS

Operating Instructions

Turn the meter on by pressing the Power button. Press and hold the

Power button to turn the meter off.

Function Selection

1. The meter’s function defaults are set to “Auto Range, “A Frequency Weighting”, and Fast Time Weighting”. The screen will display

“A. Fast Auto”.

2. Switch between “A” or “C” Frequency Weighting by pressing the

“A/C Button”.

3. Determine proper measuring range by pressing the Range Button.

Press the Range Button to scroll through the Four range types.

There are three manual ranges (range 1, range 2, range 3) and auto range in this sequence:

Range 1:

30 - 80 dB range

Range 2:

50 - 100 dB range

Range 3:

80 - 130 dB range

4. Select the Time Weighting (Fast or Slow) by pressing the Time

Weighting Button. The screen will display either “FAST” or

“SLOW”, depending on your selection.

Data Hold

While taking a measurement, press the Hold Button once and the measured value will hold on the screen, and a HOLD symbol will appear.

Press the Hold Button once again will release the data hold function.

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Blue - 100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0 reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

INSTRUMENTS

7

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Data Record (Max., Min. reading)

The data record function records the maximum and minimum readings.

Press the REC Button once to start the Data Record function and a “REC” symbol will appear on the display. With the “REC” symbol on the display:

1. Press the REC Button once, and a ”REC. MAX.” symbol along with the maximum value will appear on the display. To delete the maximum value, press the Hold Button once and the display will show a “REC.” symbol only and execute the memory function continuously.

2. Press the REC Button again, and a “REC. MIN.” symbol along with the minimum value will appear on the display. To delete the minimum value, press the Hold Button once, and the display will show a “REC.” symbol only and execute the memory function continuously.

3. To exit the memory record function, press the REC button for 2 seconds. The display will revert to the current reading.

Backlight ON/OFF

After powering the meter ON, the LCD Backlight will turn on automatically. While taking measurements, press the Backlight Button and the LCD

Backlight will turn off. Press the Backlight Button once again to turn the

LCD Backlight back ON.

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Datalogger

Preparation Before Executing the Datalogger Function:

1. Insert the optional SD card into the SD card socket.

2. Before you use an SD card with this meter for the first time, it is recommend to format the SD card. See Advanced Settings section of this manual for instructions.

3. If this is the first time the meter is used you need to adjust the clock. See Advanced Settings section of this manual for instructions.

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Pantone 534 Blue

Black reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

continued ...

8

INSTRUMENTS

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

4. Now you need to set the decimal format. The numerical data structure downloaded to the SD card is defaulted used the “.” as the decimal, for example “20.6” “1000.53”. But in certain countries the “,” is used as the decimal point, for example

“20, 6” “1000,53”. See Advanced Settings section of this manual for instructions on how to change the Decimal Character.

Auto Datalogger (Set sampling time ≥1 second)

1. Start Datalogging; press the REC Button, and the “REC” symbol will appear on the LCD screen, then press the Logger Button, the

“REC” symbol will flash while the measuring data and time information is being saved in memory. To set the sampling time, and to toggle the beeper sound on or off, refer to the Advanced Settings section of this manual.

2. Pause the Datalogging; while Datalogging, if press the Logger

Button once. While paused, the “REC” symbol will stop flashing.

Press the Logger Button again to resume Datalogging, and the

“REC” symbol will begin to flash again.

3. Stop Datalogging; while the Datalogger function is paused, press the REC Button for 2 seconds. The “REC” symbol will disappear indicating the Datalogging function has stopped.

Pantone 534 Blue

Pantone 123 Yellow

Manual Datalogger (Set sampling time = 0 seconds)

1. Set sampling time is to 0 second; Press the REC Button, and the

“REC” symbol will appear on the LCD screen. Press the Logger

Button, and the “REC” symbol will flash once and one Beep will sound, at the same time the measuring data along the time information will be saved in memory. The lower Display will show the

Position (record) number, which is saved as well.

2. To Change the Position Number; press the Down Button and the lower position number will flash on the display. Press the Up or

Blue - 100/80/30/5

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black to 99). After the position number is selected, press the Enter button to confirm.

continued ...

reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

9

INSTRUMENTS

3. Stop Datalogging; press the REC Button for 2 seconds, and the

“REC” symbol will disappear indicating the Datalogging function has stopped.

Checking the Time

During normal functions (not Datalogging), press the Time Check Button and the lower LCD display will show the Year, Month/Date, Hour/Minute.

Check Sampling Time Information

During normal functions (not Datalogging), press the Sampling Button and the lower LCD display will show the Sampling Time Information.

SD Card Data Structure

1. The first time the SD card is used in the meter, the SD card will generate a folder: “SLA01”.

2. The first time you use the Datalogger, in the folder “SLA01”, a new file name “SLA01001.xls” will be created. The Datalogger will use this file until the Data has reached to 30,000 rows. The meter will then will generate a new file with a subsequent number, for example “SLA01002.xls”.

3. The folder SLA01 can hold “99.xls” files. When that number has been reached, the meter will then will generate a new folder with a subsequent number, for example “SLA02”. Max number of

“SLA--” folders is 10.

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Blue - 100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0 reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

INSTRUMENTS

10

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Data Transfer from SD card to Computer (EXCEL Software)

1. After Datalogging, remove the SD card from the SD card slot.

2. Plug in the SD card into the Computer’s SD card slot or insert the

SD card into the optional SD card adapter and connect to your

Computer. Turn your computer on and a folder will appear on your desktop representing you SD card.

3. Open “Microsoft EXCEL”. Download the EXCEL files from the SD

Card to the computer by opening up the SD folder and selecting the desired EXCEL files, and drag-and-drop them onto your

Computer. Open the files with EXCEL (File – Open).

4. The EXCEL file will have the following column headers in this order: Place (Position Number), Date (Year/Month/Day), Time (in

24h clock), Value, and Unit.

Advanced Settings

During normal functions (not Datalogging), press and hold the SET Button for 2 seconds to enter the “Advanced Setting” mode. Press the Next Button scroll through eight main functions, shown on the lower display:

dAtE Set clock time (Year/Month/Date, Hour/Minute/Second)

dEC Set SD card Decimal character

PoFF Auto power OFF management

bEEP Set beeper sound ON/OFF

SP-t Set sampling time (Hour/Minute/Second)

Sd F SD memory card Format

Pantone 534 Blue

Pantone 123 Yellow

While in the “Advanced Setting” function, press the Esc Button to exit and to return to normal functioning.

Blue - 100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

INSTRUMENTS

11

Set Clock Time

1. When the lower display shows “dAtE”, press the Enter Button.

Use the Up and Down Buttons to adjust the Year. After the desired value is set, press the Enter Button to adjust the Month, Date,

Hour, Minute, and Second values.

2. After all the time values have been set the screen will jump to “SD card Decimal character” setting screen.

Note: After the time value is set, the internal clock will run even when the power is off, if the battery is under normal conditions.

Setting the Decimal Point on the SD Card

1. When the lower display shows “dEC”, use the Up or Down Buttons to toggle between “bASIC” (“.” Decimal Point) or “Euro” (“,”

Decimal Point).

2. After the Decimal point character has been selected, press the

Enter Button to save the setting as the default.

Auto Power OFF Management

1. When the lower display shows “PoFF”, use the Up or Down Buttons to select the value “yES” (Enable Auto Power Off) or “no”

(Disable Auto Power Off.

2. After selecting “yES” or “no”, press the Enter Button to save the setting as the default.

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Pantone 534 Blue

Pantone 123 Yellow

Set Beeper Sound ON/OFF

1. When the lower display shows “bEEP”, use the Up or Down Buttons to select “yES” (Beeper Sound is ON) or “no” (Beeper Sound is OFF).

2. After selecting “yES” or “no”, press the Enter Button to save the

Blue - 100/80/30/5

Red - 10/100/100/5

Yellow - 0/27/100/0

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

INSTRUMENTS

12

Set Sampling Time

1. When the lower display shows “SP-t”, use the Up or Down Buttons to adjust the value to either 0, 1, 2, 5, 10, 30,60, 120, 300,

600, 1800, or 3600 seconds.

2. After the Sampling value is selected, press the press the Enter

Button to save the setting as the default.

SD Memory Card Format

Please Note: Formatting the SD card erases all data from that SD card.

1. When the lower display shows “Sd F”, use the Up or Down Buttons to select “yES” (format the SD card) or “no” (do not format the SD card).

2. To format your SD card, select “yES” and press the Enter Button.

The Display will show “yES Enter”, to confirm. Press the Enter

Button to confirm.

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Blue - 100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0 reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

INSTRUMENTS

13

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

PC Serial Interface

The instrument features an PC output via 3.5 mm terminal. The connector output is a 16 digit data stream which can be utilized to the user’s specific application. An USB RS232 lead with the following connection will be required to link the instrument with the PC serial input.

Meter (3.5mm Jack Plug) PC (9W “D” Connector)

Center Pin Pin 2

Ground/Shield Pin 5

The 16 digit data stream will be displayed in the following format:

D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0

D10

D11

D12

D13

D14

D15

D0 End Word

D1 to D4 Upper Display reading, D1= LSD, D4= MSB

D5 to D8 D5=? D6=? D7=? D8=?

D9 Decimal Point ( DP) for display

0 = No DP, 1 = 1 DP, 2 = 2 DP, 3 = 3 DP

D10 = 0

D11 = 0

D12 = 0

D13 = 0

D14 = 0

Start Word

Blue - 100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0 reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

INSTRUMENTS

14

System Reset

If an error occurs, press the Reset Button with a Pin. If the Reset Button does not fix the error, please send in the unit to our Calibration Lab for repair. E-mail [email protected] for more information.

Battery Replacement

1. When the left corner of LCD display shows , it is necessary to replace the battery

2. Loosen the screws of the Battery Cover and remove

3. Remove the batteries and replace with six DC 1.5 V batteries

(UM3, AA, Alkaline/heavy duty)

4. Make sure the battery cover is properly secured after changing the battery

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Blue - 100/80/30/5

Yellow - 0/27/100/0

For service on this or any other REED product or information on other

Red - 10/100/100/5

REED products, contact REED Instruments at [email protected]

reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

15

INSTRUMENTS

Pantone 534 Blue - 100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Notes _________________________________________

________________________________________________

________________________________________________

________________________________________________

________________________________________________

________________________________________________

________________________________________________

________________________________________________

________________________________________________

________________________________________________

________________________________________________

________________________________________________

________________________________________________

________________________________________________

________________________________________________

________________________________________________

Yellow - 0/27/100/0

Yellow - 0/27/100/0 reedinstruments com

www.reedinstruments.com

Only if you REALLY need them:

INSTRUMENTS

16

advertisement

Key Features

  • Measures sound levels in accordance with IEC61672 Class 2 specifications
  • A/C frequency weighting
  • Fast/Slow time weighting
  • Peak hold, Data hold and Max/Min record
  • Real time data logger with integral 4GB SD memory card
  • Just plug the SD card into the computer and it downloads directly to EXCEL
  • RS232 and USB computer interface
  • Easy to read LCD with backlight
  • Auto or manual power off
  • Includes Batteries

Frequently Answers and Questions

How do I turn the Sound Level Meter SD 4023 on and off?
Press the Power button to turn the meter on. Press and hold the Power button to turn the meter off.
What is the difference between A and C frequency weighting?
A weighting is used to measure sound levels in a way that simulates how the human ear perceives sound. C weighting measures all frequencies equally.
How do I use the data logger function?
First, insert an SD card into the SD card slot. Then, press the REC button to start recording. Press the Logger button to pause or resume recording. Press the REC button for 2 seconds to stop recording.
How do I download the data from the SD card to my computer?
Remove the SD card from the meter. Insert the SD card into your computer's SD card slot. Open the SD card folder and select the desired EXCEL files. Drag-and-drop the files onto your computer. Open the files with EXCEL.
How do I change the time on the Sound Level Meter SD 4023?
Press and hold the SET button for 2 seconds to enter the “Advanced Setting” mode. Press the Next button to scroll through the settings. When the lower display shows “dAtE”, press the Enter button. Use the Up and Down buttons to adjust the Year, Month, Date, Hour, Minute, and Second values.

Related manuals

Download PDF

advertisement