WASHER/DRYERSAFETY
27 IN. (69CM)ELECTRIC WAStlER/DRYER
INSTAILATION INSTRUCTIONS
Tableof Contents
WASHER/DRYER
SAFETY .............................. 1
INSTALLATION INSTRUCTIONS .................... 2
Tools and Parts ............................................. 2
Alternate Parts ...............................................
Install Leveling Legs ....................................
Connect the Drain Hose ..............................
Connect the Inlet Hoses .............................
10
10
11
2
Secure the Drain Hose ................................
11
Location Requirements ................................ 2
Drain System .................................................
3
Plan Vent System ........................................
Install Vent System ......................................
12
13
Electrical Requirements ................................. 4
Electrical Connection .................................... 5
Level Washer/Dryer .....................................
Connect Vent ..............................................
14
14
Venting Requirements ................................... 9
Remove Shipping Strap .............................. 10
Complete Installation ..................................
14
WASHER/DRYER
SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
8542746
INSTAILATIONINSTRUCTIONS
Check that you have everything necessary for correct installation.
Proper installation is your responsibility.
Your installation may require additional parts. For ordering
information, please refer to the toll free phone numbers on the
front page of your "Washer/Dryer User Instructions."
Tools needed:
•
#2 Phillips and flat-blade
screwdriver
•
Adjustable wrench that
opens to 1 in. (2.5 cm) or
9/16in. open-end wrench
(for adjusting dryer feet)
Level
•
•
•
Knife
•
Safety glasses
•
•
Vent clamps
Caulking gun and
compound (for installing
new exhaust vent)
1/4in. nut driver or socket
wrench
•
•
Gloves
Pliers
•
Wood block(for
leveling)
•
Scissors
•
Ruler or measuring tape
•
Tin snips (for new vent
•
Wire stripper (direct wire
installations)
6
Water inlet hoses (2)
Inlet hose flat washers (4)
Front leveling feet with nuts (2)
Shipping strap (not in parts bag,
see "Remove Shipping Strap")
You Will Need to Buy
Laundry tub or
standpipe taller than
96 in. (2.4 m)
Sump pump system (if not already
available)
1 in. (2.5 cm)
diameter standpipe
2 in. (5 cm) diameter to 1 in. (2.5 cm)
diameter standpipe adapter, Part
Number 3363920
Overhead sewer
Standard 20 gal. (76 L) 34 in. (86.4 cm)
tall drain tub or utility sink and sump
pump (available from local plumbing
suppliers)
Floor drain
Siphon break, Part Number 285320,
additional drain hose, Part Number
285702 and connector kit,
Part Number 285442
Drain hose too short
Drain hose, Part Number 285664 and
connector kit, Part Number 285442
Lint clogged drain
Drain protector, Part Number 367031
Water faucets
beyond reach of fill
hoses
2 longer water fill hoses:
6 ft (1.8 m) Part Number 76314,
10 ft (3.0 m) Part Number 350008
installations)
Parts supplied:
Remove parts package from the washer basket. Check that all
parts were included.
!.
2.
3.
4.
If You Have
7
5. Drain hose
6. Yellow, single wire hose
clamp
7. Silver, double wire hose
clamp
Parts needed:
Check local codes, electrical supply and venting, and read
"Electrical Requirements" and "Venting Requirements" before
purchasing parts.
Mobile home installations require metal exhaust system hardware
available for purchase from the dealer from whom you purchased
your washer/dryer. For further information, please reference the
"Assistance or Service" section of your "Washer/Dryer User
Instructions."
Explosion
Hazard
Keep flammable materiaBs and vapors, such as
gasoline, away from dryer.
Failure to do so can result in death, expmosion, or fire.
You will need
•
A location that allows for proper exhaust installation. See
"Venting Requirements."
•
A separate 30 amp circuit.
•
A grounded electrical outlet located within 2 ft (61 cm) of
either side of the washer/dryer. See "Electrical Requirements."
•
A sturdy floor to support the washer/dryer weight (washer/
dryer, water and load) of 500 Ibs (226.8 kg).
• Alevelfloorwithamaximum
slopeof1in.(2.5cm)under
entirewasher/dryer.
Clothes
maynottumble
properly
and
automatic
sensor
cyclesmaynotoperate
correctly
ifdryeris
notlevel.Installing
oncarpetisnotrecommended.
• Awaterheater
settodeliver
120°F
(49°C)
watertothewasher.
• Hotandcoldwaterfaucets
located
within4ft (1.2m)ofthe
hotandcoldwaterfillvalves,
andwaterpressure
of5-100psi
(34.5-689.6
kPa).
Thewasher/dryer
mustnotbeinstalled
orstored
inanareawhere
itwillbeexposed
towaterand/orweather.
Donotoperate
yourwasher
intemperatures
atorbelow32°F
(0°C).
Somewatercanremain
inthewasher
andcancause
damage
inlowtemperatures.
See"Washer/Dryer
Care"inyour
"Washer/Dryer
UserInstructions"
forwinterizing
information.
Donotoperate
yourdryerattemperatures
below45°F(7°C).
At
lowertemperatures,
thedryermightnotshutoffattheendofan
automatic
cycle.Thiscanresultinlonger
dryingtimes.
Check
coderequirements.
Somecodeslimit,ordonotpermit,
installation
ofthewasher/dryer
ingarages,
closets,
mobile
homes,
orsleeping
quarters.
Contact
yourlocalbuilding
inspector.
Installation Clearances
The location must be large enough to fully open the dryer door.
Washer/Dryer
Dimensions
Rear clearance may be 0 in. when house exhaust system is
lined up directly with dryer exhaust.
_(15=2era)
(3!0
3" (7=6cm)
cm _)
(155 cra)
3" (7=_¢m)
(0era
69=5em
0¢rn)
(2.5cm) (81=9cm)
(14cm)
2
1. Recessed area
2. Side view - closet or confined area
3. Closet door with vents
Mobile Home - Additional Installation Requirements
This washer/dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
Safety, Title 24, HUD Part 280).
Mobile home installations
require:
•
Metal exhaust system hardware which is available for
purchase from your dealer.
•
and
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
723/4"
(184=8cm)
The washer/dryer can be installed using the standpipe drain
system (floor or wall), the laundry tub drain system, or the floor
drain system. Select the drain hose installation method you need.I
See "Alternate Parts."
* Most installations require a minimum 51/2in. (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Standpipe drain system - wall or floor (view I & 2)
The standpipe drain requires a minimum diameter standpipe of
2 in. (5 cm). The minimum carry-away capacity can be no less
than 17 gal. (64 L) per minute. A 2 in. (5 cm) diameter to 1 in. (2.5
cm) diameter standpipe adapter kit is available. See "Alternate
Parts."
The top of the standpipe must be at least 39 in. (99 cm) high and
no higher than 96 in. (2.4 m) from the bottom of the washer.
Minimum installation spacing for recessed area or closet
installation
The following dimensions shown are for the minimum spacings
allowed.
•
Additional spacing should be considered for ease of
installation and servicing.
•
Additional clearances might be required for wall, door and
floor moldings.
•
Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Laundry tub drain system (view 3}
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top
of the laundry tub must be at least 34 in. (86.4 cm) above the floor
and no higher than 96 in. (2.4 m) from the bottom of the washer.
Floor drain system (view 4)
The floor drain system requires a siphon break that may be
purchased separately. See "Alternate Parts."
The siphon break must be a minimum of 28 in. (71 cm) from the
bottom of the washer. Additional hoses might be needed.
If your outlet looks like this:
4-wire receptacle
(14-30R)
Then choose a 4-wire power supply cord with ring or spade
terminals and UL approved strain relief. The 4-wire power supply
cord, at least 4 ft (1.22 m) long, must have 4, 10-gauge solid
copper wires and match a 4-wire receptacle of NEMA Type 1430R. The ground wire (ground conductor) may be either green or
bare. The neutral conductor must be identified by a white cover.
If your outlet looks like this:
3-wire receptacle (10-30R)
It is your responsibility
•
To contact a qualified electrical installer.
•
•
To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
To supply the required 3 or 4 wire, single phase, 120/240-volt,
60-Hz., AC-only electrical supply (or 3 or 4 wire, 120/208-volt
electrical supply, if specified on the serial/rating plate) on a
separate 30-ampere circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
•
Flexible armored cable or nonmetallic sheathed copper cable
(with ground wire), protected with flexible metallic conduit. All
current-carrying wires must be insulated.
•
10-gauge solid copper wire (do not use aluminum.)
•
At least 5 ft (1.52 m) long.
Do not use an extension cord.
•
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Electrical
Connection
To properly install your washer/dryer, you must determine the type
of electrical connection you will be using and follow the
instructions provided for it here.
•
If local codes do not permit the connection of a cabinet
ground connector to the neutral wire, see "Optional 3-wire
Connection."
•
This washer/dryer is manufactured with a 3-wire, cabinetground conductor connected to the NEUTRAL (white or
center wire) of the wiring harness at the terminal block.
•
Use a 4-wire conductor cord when the washer/dryer is
installed in a mobile home or an area where local codes do not
permit grounding through the neutral.
If using a power supply cord:
•
Use a UL approved power supply cord kit marked for use with
clothes dryers. The kit should contain:
•
a 3-wire power supply cord with ring or spade
UL approved strain relief. The 3-wire power supply
4 ft (1.22 m) long, must have 3, 10-gauge solid
and match a 3-wire receptacle of NEMA Type 10-
A copy of the above code standards can be obtained from:
National Fire Protection Association, Batterymarch Park,
Quincy, MA 02269.
•
•
Then choose
terminals and
cord, at least
copper wires
30R.
A UL approved 30 amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be at
least 4 ft (1.22 m) long. The wires that connect to the dryer
must end in ring terminals or spade terminals with upturned
ends.
A UL approved strain relief.
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected washer/dryer:
This washer/dryer must be grounded. Hnthe event of malfunction or breakdown, grounding will reduce the risk of electric
shock by providing a path of least resistance for electric
current. This washer/dryer uses a cord having an equipmentgrounding conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
[] For a permanently connected washer/dryer:
This washer/dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected
to the equipment_grounding terminal or lead on the
washer/dryer.
WARNING:
Hmproper connection of the equipmentgrounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the washer/dryer
is properly grounded. Do not modify the plug on the power
supply cord: if it wiiI not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE
THESE
INSTRUCTIONS
Power
Supply
Cord
DirectWire
Fire Hazard
Fire Hazard
Use a new UL approved
Use a UL approved
Disconnect
30 amp power supply
Use t0 gauge somid copper
cord,
Use a UL approved
strain retief.
power before making
Disconnect
emectrical connections.
power before making emectricamconnections.
Ground wire (green or bare wire) must be connected
green ground connector,
to
Connect remaining 2 suppmy wires to remaining
2 terminals (gored).
Connect remaining 2 suppmy wires to remaining
2 terminals (gold).
Securemy tighten
Securely tighten
aimeJectrical
connections,
Disconnect power.
Remove the hold-down
to
aimemectrica{ connections.
Failure to do so can result in death, fire, or
electrica_ shock.
Failure to do so can resumt in death, fire, or
emectrical shock,
1.
2.
retief,
Connect neutral wire (white or center wire) to center
terminal (simver).
Connect neutram wire (white or center wire) to center
terminal (silver),
Ground wire (green or bare wire) must be connected
green ground connector.
strain
wire,
3.
screw and terminal block cover.
I
Assemble a 3/, in. (1.9 cm) UL approved strain relief (UL
marking on strain relief) into the hole below the terminal block
opening. Tighten strain relief screws just enough to hold the
two clamp sections together. Put power supply cord through
the strain relief, The strain relief should have a tight fit with the
dryer cabinet.
2
Now complete installation following instructions for your type
of electrical connection:
5
1. Center,silver-colored terminal block screw
2. Hold-down screw
3. Terminalblock cover
4. Neutral grounding wire (green/yellow)
5. Externalground connector
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
If your home has:
And you will be
connecting to:
Go to Section
4-wire receptacle
(NEMA Type 14-30R)
A UL listed, 120/
240 volt
4-wire connection:
Power supply cord
1.
Remove center terminal block screw.
2.
Remove appliance ground wire (green with yellow stripes)
from external ground connector screw. Fasten it under center,
silver-colored terminal block screw.
1
2
amp., dryer
power
supply
minimum,
30
cord*
4-wire direct
3-wire receptacle
(NEMA type 10-30R)
A fused
disconnect or
circuit breaker
box*
4-wire connection:
Direct Wire
A UL listed, 120/
240 volt
3-wire connection:
1. Neutral grounding wire (green/yellow)
2. Center silver-colored terminal block screw
3. External ground connector
4.
amp., dryer
power supply
minimum, 30
cord*
3-wire direct
A fused
disconnect or
circuit breaker
box*
3=
Power supply cord
Connect ground wire (green or bare) of power supply cord to
external ground conductor screw. Tighten screw.
Connect neutral wire (white or center wire) of power supply
cord under center screw of the terminal block. Tighten screw.
4
3-wire connection:
Direct Wire
2
* If local codes do not permit the connection of a framegrounding conductor to the neutral wire, go to "Optional 3-wire
Connection" section.
6
4-wire connection: Power supply cord
IMPORTANT: A 4-wire connection is required for all mobile
homes and where local codes do not permit the use of 3-wire
connections.
2
3
1. External ground connector
2. Green or bare copper wire of power supply cord
3. Neutral grounding wire (green/yellow)
4. Center silver-colored terminal block screw
5. Neutral wire (white or center)
6. 3/4in. (1.9 cm) UL listed, strain relief
6
4
5
1.4-wire receptacle (NEMA type !4-30R)
2. 4-prong plug
3. Ground prong
4. Neutral prong
5. Spade terminals with upturned ends
6. ¾ in. (1.9 cm) UL approved strain relief
7. Ring terminals
7
5.
6.
7.
Connect the other wires to outer terminal block screws.
Tighten screws.
Tighten strain relief screws.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
3=
Connect ground wire (green or bare) of power supply cable to
external ground conductor screw. Tighten screw.
4.
Place the hooked end of the neutral wire (white or center wire)
of power supply cable under the center screw of terminal
block (hook facing right), Squeeze hooked end together.
Tighten screw.
4-wire connection: Direct Wire
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 5 in. (12.7 cm) of outer covering from end of cable, leaving
bare ground wire at 5 in. (12.7 cm). Cut 11/2in. (3.8 cm) from 3
remaining wires. Strip insulation back 1 in. (2.5 cm). Shape ends
of wires into a hook shape.
6
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw.
1.
Remove center terminal block screw.
2.
Remove appliance ground wire (green with yellow stripes)
from external ground connector screw. Fasten it under center,
silver-colored terminal block screw.
t
!.
2.
3.
4.
5.
6.
External ground connector
Green or bare copper wire of power supply cord
Neutral grounding wire (green/yellow)
Center sliver-colored terminal block screw
Neutral wire (white or center)
3/4in. (1.9 cm) UL listed, strain relief
Place the hooked ends of the other power supply cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!! !!
2
6.
7.
1. Neutral grounding wire (green/yellow)
2. Center silver-colored terminal block screw
3. External ground connector
Tighten strain relief screws.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw,
3-wire connection: Direct Wire
3-wire connection: Power supply cord
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
2
5
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 31/2in. (8.9 cm) of outer covering from end of cable. Strip
insulation back 1 in. (2.5 cm) If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of wires
into a hook shape.
3
1. 3-wire receptacle (NEMA type 10-30R)
2. 3-wire plug
3. Neutral prong
4. Spade terminals with up turned ends
5. ¾ in. (1.9 cm) UL approved strain relief
6. Ring terminals
7. Neutral (white or center wire)
1.
2.
Loosen or remove center terminal block screw.
Connect neutral wire (white or center wire) of power supply
cord to the center, silver-colored terminal screw of the terminal
block. Tighten screw.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw. See example
below.
3
2
?
1.
2.
Loosen or remove center terminal block screw.
Place the hooked end of the neutral wire (white or center wire)
of power supply cable under the center screw of terminal
block (hook facing right). Squeeze hooked end together.
Tighten screw.
3
J
1.
2.
3.
4.
5.
3.
4.
5.
External ground connector
Neutral grounding wire (green/yellow)
Center silver-colored terminal block screw
Neutral wire (white or center wire)
¾ in. (1.9 cm) UL-listed strain relief
4
Connect the other wires to outer terminal block screws.
Tighten screws.
Tighten strain relief screws.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
1.
2.
3.
4.
5.
External ground connector
Neutral grounding wire (green/yellow)
Center silver-colored terminal block screw
Neutral wire (white or center wire)
¾in. (1.9 cm) UL-listed strain relief
Place the hooked ends of the other power supply cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!! !!
4.
Tighten strain relief screws.
5.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
Optional 3-wire connection
Use for direct wire or power supply cord where local codes do
not permit connecting cabinet-ground conductor to neutral
wire.
1.
Remove center terminal block screw,
2.
Remove appliance ground wire (green with yellow stripes)
from external ground connector screw, Connect appliance
ground wire and the neutral wire (white or center wire) of
power supply cord/cable under center, silver-colored terminal
block screw. Tighten screw.
Connect the other wires to outer terminal block screws,
Tighten screws,
3.
Fire Hazard
Use a heavy metal vent.
Do not use a plastic
vent.
Do not use a metal foil vent.
Failure to follow
or fire.
4.
5.
Tighten strain relief screws.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6.
Connect a separate copper ground wire from the external
ground connector screw to an adequate ground.
these instructions
can resumt in death
WARNING:
To reduce the risk of fire, this washer/dryer
MUST BE EXHAUSTED OUTDOORS.
4 in. (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE TM venting products are recommended.
DURASAFE TM vent products can be purchased from your dealer
or by calling Whirlpool Parts and Accessories. For more
information, see the "Assistance or Service" section of your
"Washer/Dryer User Instructions."
•
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, or a concealed space of a building.
•
Do not use an exhaust hood with a magnetic latch.
•
Do not install flexible metal vent in enclosed walls, ceilings or
floors.
•
Use clamps to seal all joints. Exhaust vent must not be
connected or secured with screws or other fastening devices
which extend into the interior of the duct. Do not use duct
tape.
IMPORTANT: Observe all governing codes and ordinances,
1.
2.
3.
4.
External ground connector
Neutral grounding wire (green/yellow)
Neutral wire (white or center wire)
Grounding path determined by a qualified electrician
_mproper venting can cause moisture
indoors, which may resumt in:
[]
Moisture damage to woodwork,
paper, carpets, etc=
[]
Housecleaning
and mintto co,meet
furniture, paint, waif
problems and health problems.
Use a heavy metal vent. Do not use plastic or metal foil vent.
Rigid metal vent is recommended to prevent crushing and kinking.
Flexible metal vent must be fully extended and supported when
the washer/dryer is in its final position. Remove excess flexible
metal vent to avoid sagging and kinking that may result in reduced
airflow and poor performance.
An exhaust hood should cap the vent to prevent rodents and
insects from entering the home.
Exhaust hood must be at least 12 in. (30.5 cm) from the ground or
any object that may be in the path of the exhaust (such as flowers,
rocks or bushes, etc.).
If using an existing vent system, clean lint from the entire length of
the system and make sure exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid metal or flexible
metal vent.
Excessive Weight Hazard
Use two or more people to move and install
washer/dryer.
Failure to do so can result in back or other injury.
To prevent floor damage, set washer/dryer onto cardboard before
moving across floor. Move washer/dryer close to its final location.
1. Do not cut yellow strap. Pull yellow strap firmly, until
completely removed from washer/dryer. There should be 2
cotter pins on the end of the shipping strap. The electrical
plug is attached to this shipping strap.
2.
3.
Tilt the washer/dryer forward. Move each of the 2 rear legs in
an up-down motion to check the self-adjusting leveling legs
for free movement. This is required for proper leveling. Gently
lower the washer/dryer to the floor.
Cut the shipping strap about 16 in. (40.6 cm) from the plug
end. Look for the words "CUT HERE." Discard end with cotter
pins. You will use the remaining piece of shipping strap to
secure the drain hose.
Proper connection of the drain hose protects your floors from
damage due to water leakage. To prevent the drain hose from
coming off or leaking, it must be installed per the following
instructions:
IMPORTANT: To ensure proper installation, this procedure must
be followed exactly.
1.
Check the drain hose to see whether it is the proper length.
2.
Wet the inside of the straight end of the drain hose with tap
water. DO NOT USE ANY OTHER LUBRICANT.
3.
Squeeze ears of the silver, double-wire clamp with pliers to
open. Place clamp over the straight end of the drain hose
1Ain. (6.4 mm) from the end.
4.
Open clamp. Twist hose back and forth while pushing onto
drain connector on the side of the washer/dryer. Continue until
hose contacts the ribbed stops on the cabinet.
5.
Place clamp over the area marked "CLAMR" Release clamp.
For laundry tub or standpipe drain systems
1. Open the yellow, single-wire clamp and slide over the hooked
end of the drain hose to secure the rubber and corrugated
sections together.
Install the front leveling feet
1. Prop up the front of the washer/dryer about 4 in. (10.2 cm)
with a wood block or similar object. The block needs to
support the weight of the washer/dryer.
2. Screw the lock nut onto each foot to within I in. (2.5 cm) of the
base.
!. Hooked end
2. Drain hose
1 "
(2.5crn)
2.
s
Put hooked end of drain hose into laundry tub or standpipe.
Rotate hook to eliminate kinks.
To prevent drain water from going back into the washer:
3.
Screw the feet into the correct holes at the front corner of the
washer/dryer until the nuts touch the washer.
NOTE: Do not tighten the nuts until the washer/dryer is level.
4.
Tilt the washer/dryer back and remove the wood block, Gently
lower the washer/dryer to the floor.
10
•
Do not straighten hooked end of the drain hose and force
excess drain hose into standpipe. Hose should be secure but
loose enough to provide a gap for air.
•
Do not lay excess hose on the bottom of the laundry tub.
For use with floor drain
Remove the drain hose hook from the corrugated drain hose. You
may need additional parts. See "Floor Drain" under "Alternate
Parts."
_,_
1.
_j=
_/_t, t,,=C_ _
Insert a new flat washer (supplied) into each end of the inlet
hoses. Firmly seat the washers in the couplings.
1
2
1. Coupling
2. Washer
Connect
the inlet hoses to the water faucets
Make sure the washer basket is empty.
2. Attach the hose with the red coupling to the hot water faucet.
Screw on coupling by hand until seated on the washer.
3. Attach the hose with the blue coupling to the cold water
faucet. Screw on coupling by hand until seated on the washer.
4. Using pliers, tighten the couplings with an additional twothirds turn.
NOTE: Do not overtighten.
6.
NOTE: Replace inlet hoses after 5 years of use to reduce the risk
of hose failure. Record hose installation or replacement dates for
future reference.
•
If you connect only one water hose, you must cap off the
remaining water inlet port.
•
Periodically inspect and replace hoses if bulges, kinks, cuts,
wear, or leaks are found.
1.
Move the washer/dryer to its final location and remove any
cardboard used to move the washer/dryer.
2.
Locate the remaining piece of shipping strap (see "Remove
Shipping Strap").
Shipping Strap
Run water through both faucets and inlet hoses, into a bucket
or laundry tub, to get rid of particles in the water lines that
might clog the inlet valve screens.
Connect
Check for leaks
8. Turn on the water faucets and check for leaks. A small amount
of water might enter the washer. You will drain this later.
Damage to the valves can result.
Clear the water lines
5.
If you are working in a closet or recessed area
Move the washer/dryer into its final position and remove
cardboard from under washer/dryer. Remove the access panel by
removing 3 Phillips-head screws and one bumper, located at the
top of the access panel. Set panel, screw, and bumper aside.
Complete hookup of water hoses and (on gas models) the flexible
gas connector through the access area. Replace access panel
upon completion of washer/dryer installation.
Wrap the drain hose to the laundry tub leg or standpipe with
the shipping strap (1 or 2 below). Push fastener into the
nearest hole in the shipping strap (see illustration above).
the inlet hoses to the washer
Attach the hose with the blue coupling to the cold water (top)
inlet valve. Screw on coupling by hand until seated on the
washer. Using pliers, tighten the couplings with an additional
two-thirds turn.
NOTE: Do not overtighten.
Damage to the valves can result.
If the water faucets and the drain standpipe are recessed, put
the hooked end of the drain hose in the standpipe. Tightly
wrap the shipping strap around the water inlet hoses and the
drain hose (3 above). Push fastener into the nearest hole in the
shipping strap (see illustration above).
1. Cold water inlet valve (blue)
2. Hot water inlet valve (red)
7.
Attach the hose with the red coupling to the hot water
(bottom) inlet valve. Screw on coupling by hand until seated
on the washer. Using pliers, tighten the couplings with an
additional two-thirds turn.
NOTE: Do not overtighten.
Damage to the valves can result.
11
Alternate
Typical exhaust installations
Typical installations vent the dryer from rear of the washer/dryer.
Other installations are possible.
installations
for close clearances
Venting systems come in many varieties. Select the type best for
your installation, Three close-clearance installations are shown.
Refer to the manufacturer's instructions provided with the vent
system.
4
I .....................
!
1. Loop system with standard elbows
2. Loop system with one offset & one standard elbow
3. Vent system with one periscope [2 in. (5 cm) clearance]
1. Dryer
2. Rigid metal or
flexible metal vent
3. Clamps
4. Wall
5.
6.
7.
8.
Elbow
Clamps
Elbow
Exhaust hood
NOTE: The following kits for close clearance alternate installations
are available for purchase. Please reference the "Assistance or
Service" section of your "Washer/Dryer User Instructions."
•
Over thetop Installation:
Part Number 4396028
Optional exhaust installations
This washer/dryer can be converted to exhaust out the right or left
side. To convert the washer/dryer, use Side Exhaust Kit Part
Number 279823. If four washer/dryer was previously exhausted
from the right or left side, it can be converted to rear exhaust by
using standard offset connections. To cover the hole in the side,
one of the following plugs can be added:
692790 (white)
3977784 (biscuit)
Follow the instructions in the kit to install. Kits are available from
the dealer from whom you purchased your washer/dryer.
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0 in, (0 cm) to 18 in. (45,72 cm)
mismatch
Part Number 4396011 - 18 in, (45.72 cm) to 29 in. (73.66 cm)
mismatch
Part Number 4396014 - 29 in. (73.66 cm) to 50 in. (127 cm)
mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home, Terminate the exhaust vent outside.
L
K
1. Standard rear offset exhaust installation
2. Rear exhaust for offset close clearance connection
3. Left or right side exhaust installation
12
Determine Vent Length
1. Select the route that will provide the straightest and most
direct path outdoors. Plan the installation to use the fewest
number of elbows and turns. When using elbows or making
turns, allow as much room as possible. Bend vent gradually to
avoid kinking. Avoid 90 ° turns.
3.
Determine the number of elbows you will need.
IMPORTANT" Do not use vent runs longer than those
specified in Vent Length Chart.
The following chart helps you determine your maximum vent
length based on the number of 90 ° turns or elbows you will
need and the type of vent (rigid or flexible metal) and hood
that you will use.
Vent Length Chart
2=
No. of
go° turns
or elbows
Type of Vent
Box or
Louvered
hoods
Angled
hoods
0
Rigid metal
Flexible metal
37 ft (11.3 m)
25 ft (7.6 m)
35 ft (10.7 m)
20 ft (6.1 m)
1
Rigid metal
Flexible metal
32 ft (9.7 m)
21 ft (6.4 m)
27 ft (8.2 m
16 ft (4.9 m)
2
Rigid metal
Flexible metal
24 ft (7.3 m)
15 ft (4.6 m)
19 ft (5.8 m)
10 ft (3.0 m)
Determine vent length.
The maximum length of the exhaust system depends upon:
•
•
The type of vent (rigid metal or flexible metal).
The number of elbows used.
•
Type of hood.
Recommended hood styles are shown here.
2
NOTE: Side exhaust adds a 90 ° turn inside the washer/dryer. To
determine maximum exhaust length, add one 90 ° turn to the
chart.
1.
2.
(10.2 or#)
1. Louvered hood style
2. Box hood style
3.
4.
The angled hood style (shown following) is acceptable.
(Optional) Put on safety glasses and gloves.
Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4 in. (10.2 cm) clamp.
Run vent to dryer location. Use the straightest path possible.
see "Determine Vent Length." Avoid 90 ° turns. Use clamps to
seal all joints. Do not use duct tape, screws or other fastening
devices that extend into the interior of the vent to secure vent.
See the exhaust vent length chart that matches your hood
type for the maximum vent lengths you can use.
Exhaust systems longer than specified will:
•
Shorten the life of the dryer.
•
Reduce performance, resulting in longer drying times and
increased energy usage.
13
Properly leveling your washer/dryer
vibration.
1.
prevents excessive noise and
1.
Check the levelness of the washer/dryer by placing a level on
the top edge of the washer, first side to side, then front to
back.
2.
2=
If the washer/dryer is not level, prop up the front with the
wood block and adjust the feet up or down as necessary.
Remove wood block.
3.
(On gas models) Check to be sure there are no kinks in the
flexible gas line.
1.
Check to be sure all parts are now installed. If there is an extra
part, go back through the steps to see which step was
skipped.
2.
3.
Check to be sure you have all of your tools.
Dispose/recycle all packaging materials. Keep the plastic
foam for use if the washer/dryer should be transported.
Check the washer/dryer's final location. Be sure the vent is not
crushed or kinked.
4.
5.
6.
7.
Check to be sure the washer/dryer is level and front leveling
feet are tight. See "Level Washer/Dryer."
Plug into a grounded outlet. Turn power on.
Check to be sure the water faucets are on.
8.
Check for leaks around faucets and inlet hoses.
9.
Remove the blue protective film on the console and any tape
remaining on the washer/dryer.
Read your "Washer/Dryer User Instructions."
Wipe the dryer drum interior thoroughly with a damp cloth to
remove any dust.
To test the washer, measure 1/2the normal recommended
amount of detergent and pour it into the washer. Close the lid.
Select HEAVY DUTY and pull out the Cycle Control knob.
Allow the washer to complete one whole cycle.
To test the dryer, set the dryer on a full heat cycle (not an air
cycle) for 20 minutes and start the dryer.
If the dryer will not start, check the following:
10.
11.
3.
Tilt the washer/dryer forward until the rear of the washer/dryer
is at least 4 in. (10.2 cm) off the floor. You may hear the selfadjusting rear feet click into place. Lower the washer/dryer to
the floor. Check the levelness of the washer/dryer with a level
as shown above.
If washer/dryer will not level, recheck rear leveling legs for free
movement as described in the "Install Leveling Legs" section.
Repeat until the washer/dryer is level.
4.
Using a 4 in. (10.2 cm) clamp, connect vent to exhaust outlet
in washer/dryer. If connecting to existing vent, make sure the
vent is clean. The vent must fit over the exhaust outlet and
inside the exhaust hood. Make sure the vent is secured to
exhaust hood with a 4 in. (10.2 cm) clamp.
Move washer/dryer into final position. Do not crush or kink
vent. Make sure washer/dryer is level.
12.
13.
NOTE: It may be necessary to level the dryer again after it is
moved into its final position.
•
Controls are set in a running or "On" position.
•
Start button has been firmly pushed.
After the washer/dryer is in the final location and level, use an
adjustable or open-end wrench to turn the nuts on the front
feet tightly against the washer cabinet.
If the nuts are not tight against the washer cabinet, the
washer/dryer may vibrate.
•
Washer/dryer is plugged into a grounded outlet.
•
Electrical supply is connected.
•
House fuse is intact and tight; or circuit breaker has not
tripped.
•
Dryer door is closed.
14. When the dryer has been running for 5 minutes, open the
dryer door and feel for heat.
If you do not feel heat, turn the dryer off and check the
following:
•
There may be 2 fuses or circuit breakers for the dryer.
Check to make sure both fuses are intact and tight, or that
both circuit breakers have not tripped. If there is still no
heat, contact a qualified technician.
NOTE: You may notice a burning odor when dryer is first heated.
This odor is common when the heating element is first used. The
odor will go away.
14
15
8542746
(c) 2003.
All rights reserved.
Benton Harbor, Michigan 49022
TM DURASAFE is a trademark of Whirlpool,
U.S.A.
7/03
Printed in U.S.A.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project