MS8265 Digital Multimeter Operator’s Instruction Manual
Below you will find brief information for Digital Multimeter MS8265. The Digital Multimeter MS8265 is a handheld digital multimeter that can be used to measure a variety of electrical parameters, including AC and DC voltage, resistance, capacitance, frequency, and current. It is also equipped with a diode test function, a continuity check function, and a transistor test function.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
HANDHELD
DIGITAL MULTIMETER
OPERATOR’S
INSTRUCTION MANUAL
Table of Contents
TITLE
1. GENERAL INSTRUCTIONS
1.1 Precaution safety measures
1.1.1 Preliminary
1.1.2 During use
1.1.3 Symbols
1.1.4 Instructions
1.2 Protection mechanisms
2. DESCRIPTION
2.1 Instrument Familiarization
2.2 LCD Display
2.3 Key pad
2.4 Terminals
2.5 Accessories
3. FUNCTION DESCRIPTION
3.1 General Functions
3.1.1 Misconnection Alarm
3.1.2 DATA HOLD mode
3.1.3 Battery saver
3.2 Measurement Functions
3.2.1 AC and DC Voltage measurement
3.2.2 Resistance measurement
3.2.3 Diode Test
3.2.4 Continuity Check
PAGE
1
6
9
10
10
11
11
11
11
12
13
14
6
7
8
8
2
4
1
1
5
6
TITLE
Table of Contents
3.2.5 Capacitance measurement
3.2.6 Transistor measurement
3.2.7 Frequency measurement
3.2.8 Current measurement
4. TECHNICAL SPECIFICATIONS
4.1 General specifications..
4.2 Measurement specifications
4.2.1 DC Voltage
4.2.2 AC Voltage
4.2.3 Frequency
4.2.4 Resistance
4.2.5 Diode Test
4.2.6 Continuity Check
4.2.7 Transistor
4.2.8 Capacitance
4.2.9 DC Current
4.2.10 AC Current
5. MAINTENANCE
5.1 General maintenance
5.2 Battery replacement
PAGE
14
15
16
16
17
17
18
19
19
19
20
20
20
20
21
21
21
22
22
22
1. GENERAL INSTRUCTIONS
This instrument complies with IEC 1010-1 (61010-1@IEC:
2001), CAT. II 1000V and CAT. III 600V overvoltage standards. See Specifications.
To get the best service from this instrument, read carefully this user's manual and respect the detailed safety precautions.
International symbols used on the Meter and in this manual are explained in chapter 1.1.3
1.1 Precautions safety measures
1.1.1 Preliminary
* Measurement category III is for measurements performed in the building installation.
NOTE: Examples are measurements on distribution boards, circuit-breakers, wiring, including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation, and equipment for industrial use and some other equipment, for example, stationary motors with permanent connection to the fixed installation.
* Measurement category II is for measurements performed on circuits directly connected to the low voltage installation.
NOTE: Examples are measurements on household appliances, portable tools and similar equipment.
* Measurement category I is for measurements performed on circuits not directly connected to MAINS.
NOTE: Examples are measurements on circuits not derived from MAINS, and specially protected (internal)
MAINS derived circuits. In the latter case, transient stresses
1 are variable; for that reason, requires that the transient withstand capability of the equipment is made known to the user.
* When using this Multimeter, the user must observe all normal safety rules concerning:
― protection against the dangers of electric current.
― protection of the Multimeter against misuse.
* For your own safety, only use the test probes supplied with the instrument. Before use, check that they are in good condition.
1.1.2 During use
* If the meter is used near noise generating equipment, be aware that display may become unstable or indicate large errors.
* Do not use the meter or test leads if they look damaged.
* Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be impaired.
* Use extreme caution when working around bare conductors or bus bars.
* Do not operate the meter around explosive gas, vapor, or dust.
* Verify a Meter's operation by measuring a known voltage.
Do not use the Meter if it operates abnormally. Protection may be impaired. When in doubt, have the Meter serviced.
* Uses the proper terminals, function, and range for your measurements.
* When the range of the value to be measured is unknown, check that the range initially set on the multimeter is the highest possible or, wherever possible, choose the autoranging mode.
2
* To avoid damages to the instrument, do not exceed the maximum limits of the input values shown in the technical specification tables.
* When the multimeter is linked to measurement circuits, do not touch unused terminals.
* Caution when working with voltages above 60Vdc or 30Vac rms. Such voltages pose a shock hazard.
* When using the probes, keep your fingers behind the finger guards.
* When making connections, connect the common test lead before connecting the live test lead; when disconnecting, disconnect the live test lead before disconnecting the common test lead.
* Before changing functions, disconnect the test leads from the circuit under test.
* For all dc functions, to avoid the risk of shock due to possible improper reading, verify the presence of any ac voltages by first using the ac function. Then select a dc voltage range equal to or greater than the ac range.
* Disconnect circuits power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance.
* Never perform resistance or continuity measurements on live circuits.
* Before measuring current, check the meter's fuse and turn off power to the circuit before connecting the meter to the circuit.
3
* In TV repair work, or when carrying out measurements on power switching circuits, remember that high amplitude voltage pulses at the test points can damage the multimeter.
Use of a TV filter will attenuate any such pulses.
* Use the 9V NEDA battery, properly installed in the Meter's battery case, to power the Meter.
* Replace the battery as soon as the battery indicator ( ) appears. With a low battery, the Meter might produce false readings that can lead to electric shock and personal injury.
* Do not measure voltages above 600V in Category III, or
1000V in Category II installations.
* Do not operate the Meter with the case (or part of the case) removed.
1.1.3 Symbols:
Symbols used in this manual and on the instrument:
Caution: refer to the instruction manual.
Incorrect use may result in damage to the device or its components.
~
AC (Alternating Current)
DC (Direct Current)
DC (Direct Current) or AC (Alternating Current)
Earth ground
Double insulated
Fuse
Conforms to European Union directives
4
1.1.4 Instructions
* Remove test leads from the Meter before opening the
Meter case or battery cover.
* When servicing the Meter, use only specified replacement parts.
* Before opening up the instrument, always disconnect from all sources of electric current and make sure you are not charged with static electricity, which may destroy internal components.
* Any adjustment, maintenance or repair work carried out on the meter while it is live should be carried out only by appropriately qualified personnel, after having taken into account the instructions in this present manual.
* A "qualified person" is someone who is familiar with the installation, construction and operation of the equipment and the hazards involved. He is trained and authorized to energize and de-energize circuits and equipment in accordance with established practices.
* When the instrument is opened up, remember that some internal capacitors can retain a dangerous potential even after the instrument is switched off.
* If any faults or abnormalities are observed, take the instrument out of service and ensure that it cannot be used until it has been checked out.
* If the meter is not going to be used for a long time, take out the battery and do not store the meter in high temperature or high humidity environment.
5
1.2 Protection mechanisms
* Fused by the resettable fuse (F400mA/250V) during capacitance, temperature, mA and hFE measurements.
* A PTC resistor protects against permanent overvoltages of up to 250V during resistance, Frequency, continuity and diode test measurements.
2. DESCRIPTION
2.1 Instrument Familiarization
1. LCD display 2. Keypad 3. Rotary switch 4. Terminals
6
2.2 LCD Display
See Table 1 indicated for information about the LCD display.
Symbol hFE
Figure 1.Display
Table 1. Display Symbols
Meaning
The battery is low.
Warning: To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the battery indicator appears.
Indicates negative readings.
The Meter is in the Continuity Check mode.
The Meter is in the Data Hold mode
The Meter is in the Diode Test mode
The Meter is in the Transistor Test mode
7
V, mV
Table 1. Display Symbols (continued)
V: mV:
Volts. The unit of voltage.
Millivolt. 1x10
-3
or 0.001 volts.
A, mA,
μA
Ω, k
Ω,
M
Ω kHz
A: mA:
μA:
Amperes (amps). The unit of current.
Milliamp. 1x10
-3
Microamp. 1x10
or 0.001 amperes.
-6
or 0.000001 amperes
Ω: k
Ω:
M
Ω:
Ohm. The unit of resistance.
Kilohm. 1x10
3
or 1000 ohms.
6
Megohm. 1x10 or 1,000,000 ohms.
KHz: Kilohertz. 1x10
3
or 1000 hertz.
μF, nF
F:
μF: nF:
Farad. The unit of capacitance.
Microfarad.1x10
-6
Nanofarad. 1x10
or 0.000001 farads.
-9
or 0.000000001 farads.
2.3 Keypad
See Table 2 indicated for information about the keypad operations.
Table 2. Keypad
ON/OFF Any switch position turn the meter on or off
Press HOLD to enter and
HOLD Any switch position exit the Data Hold mode.
LIGHT Any switch position
Press LIGHT to turn the backlight on. After about
5 seconds, the backlight is auto-off.
2.4 Terminals
See Table 4 indicated for information about the terminals.
8
Terminal
COM
Table 4. Terminals
Description
Return terminal for all measurements.
(Receiving the black test lead or the “com” plug of the special multi-function socket)
V
ΩHz
℃mA hFE
Input for voltage, resistance, frequency, diode and continuity measurements. (Receiving the red test lead)
Input for capacitance, Temperature, hFE and
0.001mA to 200mA current measurements.
(Receiving the red test lead or the “+” plug of the special multi-function socket)
10A
Input for 200mA to 10A current measurements.
(Receiving the red test lead)
2.5 Accessories
Delivered with the multimeter:
¥ User's manual
¥ Test leads
¥ Special Multi-function socket
9
One piece
One piece
One piece
advertisement
Key Features
- Handheld design
- Measures AC/DC voltage, resistance, capacitance, frequency, and current
- Diode test function
- Continuity check function
- Transistor test function
- Data Hold mode
- Battery saver mode
- Backlight