GAT Access 6500 Access Control Terminal

GAT Access 6500 Access Control Terminal
GAT Access 6500
Access Control Terminal
Applicaion
The GAT Access 6500 is a stylish terminal for access control in leisure
facilities such as swimming pools, spas and gyms. Identification at
the terminal is by contact-free RFID data carrier (Radio Frequency
Identification).
The clear interface guides the user through the various, well-structured
levels. The different versions (see order information) give technological
flexibility.
Function description
Order information
The GAT Access 6500 reads contact-free data carriers and checks and
Description
grants authorisations. The user holds the data carrier over the round
scan field and selects the required service via the acknowledge key. The
integrated traffic light display and acoustic signal indicate authorisation.
Further functions:
• Activation of turnstiles, doors etc. via relay outputs
• Feedback inputs
• Illuminated, round scan field
• Secure data transmission between reader and data carrier
PartNo.
GAT Access 6500 B
652278
Access control terminal with monochrome display and
contact-free reader for LEGIC® data carriers
GAT Access 6500 F
828889
Access control terminal with monochrome display and
contact-free reader for MIFARETM data carriers
• Security via mechanical lock
GAT Access 6500 ISO
• Plug & Play installation
Access control terminal with monochrome display and
652379
contact-free reader for ISO 15693 data carriers
Accessories
Description
Manual GAT Access 6200/6350/6500 EN
PartNo.
169028
Installation, configuration and operating instructions in
english
GAT Holder 6050
654179
For mounting the GAT Access 6500 on a turnstile or
other applications
www.gantner.com
Valid as from August 1st 2013 • Technical data subject to modifications without notice!
DB_GAT-ACCESS6500--EN_13.indd • PartNo.: 679287
1
Technical data
Nominal voltage:
12/24 VDC (SELV - safety extra-low
voltage)
Permitted input voltage:
10 to 28 VDC
Aver. power consumption:
10 W
Data storage:
Internal flash memory for configuring
and booking memory, data preser­
vation min. 10 years
Internal clock:
Data preservation approx. 12 h
(Gold-Cap)
Reader type:
See order information
Control elements:
-4 function keys
-RFID reader
Display elements:
-Full graphics monochrome display
with white LED background lighting,
resolution 128 x 128 pixels,
visibile area 65 x 65 mm
-RFID reader (illuminated)
-Acoustic signal
-Large integrated traffic light display
(green = access granted, red =
access denied)
Host interface:
Signal inputs:
3 x optocouplers (configurable)
- Input voltage: 0 to 30 VDC
ULow < 2 VDC, UHigh > 6 VDC
- Input current: 4.5 mA
Signal outputs:
4 x relays (configurable NO/NC)
- Switching voltage: max. 30 VAC/DC
- Continuous current: max. 2 A
- Switching power: max. 60 VA
Connection terminals:
0.5 to 1.5 mm 2
Housing material:
Plastic (PC-ABS), halogen-free
Dimensions:
197 x 199 x 79 mm
(7.76 x 7.83 x 3.11 inch)
Permitted ambient temperature: -10 to +55°C
Storage temperature:
-20 to +70°C
Relative humidity:
20 to 80%, non-condensing
Protection type:
IP 54
Protection class:
III
Weight:
0.8 kg
Environment class
based on VDS 2110:
II (conditions in indoor areas)
Ethernet 10/100 Mbit/s and RS 485
Dimensions
2
199 mm (7.83“)
2
1
1. Monochrome display
5
2. Traffic light display (red/green)
6
3. Function keys
4. Illuminated, round scan field
3
5. Mounting frame
6. Display unit
4
197 mm (7.76“)
79 mm (3.11“)
Typical application
GAT Access 6500
Power supply
Network
RFID data carriers
Turnstile
2
Valid as from August 1st 2013 • Technical data subject to modifications without notice!
DB_GAT-ACCESS6500--EN_13.indd • PartNo.: 679287
www.gantner.com
Mounting and installation instructions
The mounting frame is secured by screws to the wall or the GAT Holder
Required mounting space
6050. Recommended mounting height see pictuers below. Please use the
On securing the mounting frame please ensure the specified clearances
supplied drilling template when mounting the device.
are observed to allow for removal and locking.
Wall mounting
Cables can be flush (1) or surface-mounted (2).
65.0 mm (2.56“)
When surface mounting please check whether the cables can still be
inserted once the frame has been mounted, otherwise run the cables
through the cable lead-ins prior to securing.
118 mm (4.65“)
“)
.2
(0
Cable duct for
surface-mounting
m
min. 70.0 mm (2.76“)
m
40 mm (1.57“)
101 mm (3.98“)
17.0 mm (0.67“)
Back box
Mounting frame
5
Reserve
Cable duct for
surface-mounting
2
Ø
Recommended
mounting height 1.25 m (50“)
2.5 mm (0.1“)
1
2
Back box
116 mm (4.57“)
Terminal connector with safety cap
max. 20.0 mm (0.79“)
Mounting the display unit
Once the connecting cables are wired up, the display unit is fixed onto the
mounting frame and secured with the built-in mechanical lock.
3.
4.
Cable duct for
surface-mounting
Back box
Back box
Mounting frame
2.
Cable duct for
surface-mounting
Mounting frame
Cable duct for
surface-mounting
Back box
Remove safety cap
Back box
1.
Instructions:
1. Only remove the terminal connector safety cap shortly before mounting
the display unit.
2. Rest the display unit with its top edge on the mounting frame and
swing down.
3. Push down the display unit until it clicks into the mounting frame.
4. Lock the terminal with the key and keep it in a safe place!
5. Once mounting is complete, the protective film can be removed.
www.gantner.com
Valid as from August 1st 2013 • Technical data subject to modifications without notice!
DB_GAT-ACCESS6500--EN_13.indd • PartNo.: 679287
3
Electrical connections
TCP/IP with external power supply
GAT Access 6500
e.g. Turnstile
Motor control
M
Feedback contact
TCP/IP
B
A
GND
VOut+
Mains power
Power supply unit
e.g. GAT Power Supply SP014/1
RS 485 with power supply via interface converter
Relay outputs
For activation of devices like turnstiles etc.. The relay contacts NC (breaker
B
A
0V24
to PC/server
+24 VDC
RS 232/USB
COM
Mais power
contact) and NO (maker contact) of each relay are on the same screw
terminal. To determine which contact is used set jumpers Jx below the
cover of the mounting frame. The default setting is NO.
Interface converter
ISK 200
Please observe the max. permitted switching voltages and currents (see
technical data).
Optocoupler inputs
Inputs for status acquisition. For using the input a supply voltage must be
Network
RS 485 bus connection or Ethernet.
Attention: The two interfaces must not be operated at the same time!
When using RS 485 bus connection only connect the signal lines A and B.
applied. This voltage can be taken from the terminal‘s supply or from an
external power source. Please observe the max. permitted input voltages
and currents (see technical data).
Power supply
DC supply (see technical data), e.g. via GANTNER GAT Power Supply
SP014/1 or via the interface converter ISK 200. The two screw terminals
Safety instructions
“VIN +“ are directly connected with each other internally. The power input
- This device must be installed by qualified personnel only.
is protected against reverse-polarity.
- The applicable safety and accident prevention regulations
Recommended cables
- Safety devices must not be removed.
Ethernet: min. CAT 5 (STP) for 100 MBit
- Please observe the technical data of the device specified
must be observed.
RS 485: min. CAT 5 (STP), power supply via 2 wire pairs
on the data sheet.
- The device must be disconnected from the power supply
prior to installation, assembly or dismantling.
4
Valid as from August 1st 2013 • Technical data subject to modifications without notice!
DB_GAT-ACCESS6500--EN_13.indd • PartNo.: 679287
www.gantner.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising