GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy™ Uninterruptible Power Supply SitePro 150 – 200 – 250 – 300 kVA 400 VAC CE – Series 6 SP _150 -200 _S E_01 _G PS 6_U SitePro 150 & 200 kVA Manufactured by: GE Consumer & Industrial SA General Electric Company CH – 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 51 44 www.gedigitalenergy.com GE imagination at work _250 SP -300 _S 6_UP E_ S_G 01 SitePro 250 & 300 kVA GENERAL DATA Topology Nominal output power at PF=0.6 ... 0.9 lag. Overall efficiency in VFI mode Overall efficiency in SEM mode Heat dissipation at 100% load in VFI mode, PF=0.8 lag. and charged battery Cooling air (25°C ÷ 30°C) Audible noise level Battery type Operating temperature range Storage temperature range Storage time of the battery without recharge at 20°C Relative humidity Max. altitude without power derating Power derating (according to IEC 62040-3) Protection degree Standards EMC Electrostatic discharge immunity Internal protection Transport Colour Installation Access External cable connections Cooling Paralleling (RPA version) VFI, double conversion with integrated transformer kVA 150 200 250 % Up to 92.5 % Up to 98.6 kW 10.86 14.67 19.30 300 22.58 m3/h 3170 4280 5630 6590 dB(A) 68 68 70 70 Valve regulated lead-acid (VRLA)-standard, Vented lead-acid, wet battery and NiCd UPS: 0°C ÷ 40°C Battery: 20°C ÷ 25°C recommended -25°C ÷ +55°C (higher the temperature, shorter the storage time of the battery) Max. 6 months Max. 95% (non-condensing) 1000m 1500m: -5% / 2000m: -9% / 2500m: -14% / 3000m: -18% IP 20 (IEC 60529) EN 50091 / IEC 62040, CE marking EN 50091-2 / IEC 62040-2 4kV contact / 8kV air discharge All live parts shrouded Cabinet suitable for handling by forklift RAL 9003 (white) Cabinet can be floor fixed Access required at front and rear side of the cabinet Bottom and top (rear) Forced bottom to top by internal blowers Up to 8 units parallelable for redundancy or capacity in RPA configuration (optional) RECTIFIER Rectifier bridge Standard input voltage Other input voltages Input frequency Power factor Inrush current Power walk-in Output voltage tolerance DC voltage ripple DC current ripple Battery charging characteristic Battery charging current limit Input power data Input power at inverter nominal load and charged battery Max. input power at inverter nominal load and max. battery recharge current (programmable) Max. battery charging current (programmable) at the beginning of battery recharge at nominal load Modifications reserved TDS_SPE_XXX_M15_M30_6GB_V060.doc Three phase, 6 thyristors, overtemperature protection (250 - 300 kVA: 12 pulse ready) Nominal: 3 x 380V / 400V / 415V + N Rectifier accepted ph-ph voltage range: 320V ÷ 460V (320V only for 405 VDC battery floating) On request 50/60 Hz +/-10% (45 ÷ 66 Hz) >0.8 lag. Limited by soft-start circuit >30 seconds +/- 1% <1% Max. 5% of the battery capacity [Ah], expressed in A IU (DIN 41773), T° compensated floating voltage Programmable kVA 150 200 250 at PF=0.8 lag. 130.9 174.7 219.3 kW at PF=0.9 lag. 147.2 246.7 196.5 kW at PF=0.8 lag. at PF=0.9 lag. A 300 262.6 295.4 162.5 216.6 271.8 325.9 80 39 106 51 133 65 160 78 Page 2/5 Technical Data Sheets SitePro 150-200-250-300 kVA BATTERY Battery type Number of cells Float voltage at 20°C Min. discharge voltage (programmable) Recharge time “Battery to earth” fault detection Automatic and manual battery test Battery switch Battery power data DC power at full load and PF=0.8 lag. DC power at full load and PF=0.9 lag. DC power at full typical computer load (PF=0.66 lag.) Matching battery cabinets Valve regulated lead-acid (VRLA)-standard, Vented leadacid, wet battery and NiCd 180 to 192, placed in external cabinet 405 ÷ 436V (dependent on the number of blocks) 1.65V / cell <5 hours up to 90% of battery capacity Standard Standard Standard 150 200 250 300 kVA kW 129.0 172.1 215.1 258.1 kW 145.2 193.6 241.9 290.3 kW 106.5 141.9 177.4 212.9 See optional features on page 3 INVERTER Nominal output power at PF=0.6 ... 0.9 lag. Nominal output voltage (on site programmable) Inverter bridge Output transform (for galvanic separation) Output waveform Output voltage tolerance: - static ................................................................................................................ - dynamic (at load step 0 – 100 – 0%) ................................................. - dynamic (at load step 0 – 50 – 0%).................................................... - recovery time to +/-1% ........................................................................... - output voltage THD for 100% linear load ....................................... - output voltage THD for 100% non-linear load (EN 50091) Output voltage tolerance at 100% unbalanced load (Ph-N) Output frequency Output frequency tolerance: - free-running ................................................................................................. - with mains synchronisation adjustable to ..................................... Phase displacement: - at 100% balanced load ........................................................................... - at 100% unbalanced load...................................................................... Overload capability (at PF=0.8) Short-circuit characteristic Protection clearance capability (selectivity) Crest factor 150 – 200 – 250– 300 kVA 3 x 380V / 400V / 415V + N SVM (Space Vector Modulation) and IGBT technology Standard Sine wave +/- 1% +/- 3% +/- 2% 20 ms <1% <2% +/- 3% 50/60 Hz (selectable) +/- 0.1% +/- 4% 120°: +/- 1% 120°: +/- 2% 125% - 10 minutes, 150% - 1 minute Electronic short-circuit protection, current limit to 2.2 times In for 200 ms 20% In within 5-10 ms (with MTCB class C or magnetic trip at max. 10 In) >3:1 BYPASS Input connection Primary components Voltage limits for inverter/bypass load transfers Overload on bypass Separate (dual input-recommended) or common to the rectifier input - Static switch (SCR) on bypass - Electromechanic contactors (backfeed protection) - 2 manual switches for maintenance bypass +/- 10% (adjustable) 200% for 5 minutes (1 minute for 200 kVA) and 1000% for 10 ms, non repetitive INTERFACING 6 programmable signalling voltage-free contacts (available on Delta and block terminals) Serial channel RS232 (on Delta 9 pin connector) Input signals Auxiliary power supply - Standard information for easy integration and signalling - 27 user settable signals Standard - EPO - Emergency Power Off (n/c contact, customer supplied) - GEN ON (emergency power supply ON, n/o contact, customer supplied) - 2 auxiliary signals with settable functionality - 230 VAC single phase outlet (EU type) - 24 VDC auxiliary power supply (optional) Note: all indicated values are typical. Variations may be found from one unit to another. Modifications reserved TDS_SPE_XXX_M15_M30_6GB_V060.doc Page 3/5 Technical Data Sheets SitePro 150-200-250-300 kVA FRONT PANEL CONTROLS, SIGNALS AND ALARMS • • • • Synoptic diagram of the UPS: represents the operational status with integrated LEDs and power flow indicators. SERVICE CHECK (LED): turns on when maintenance is due or the manual bypass is active. COMMON ALARM: visual (LED) and audible signal (buzzer), active when an alarm condition is present. STOP OPERATION: visual (LED) and audible signal (buzzer) active approx. 3 minutes before complete and automatic load disconnection (due to an overtemperature condition or fully discharged battery). • LOAD LEVEL, BATTERY AUTONOMY: status indicator bar graphs. • MONITORING SYSTEM with multi language LCD display and control keys. • Push-buttons: - INVERTER ON - INVERTER OFF - MUTE - LAMP TEST - LOAD OFF (key with protective cover): to be pressed for emergency load disconnection. OPTIONS BUILT-IN UPS OPTIONS: 1. RPA kit 2. 24 VDC Auxiliary Power Supply COMMUNICATION: 1. Advanced SNMP Card 2. JUMP software suite 3. IRIS service 4. Modbus RTU Interface 5. RMS - Remote Monitoring System (Cable for connection to UPS not included) 6. RSB - Remote Signalling Box (Cable for connection to UPS not included) OPTIONS IN ADDITIONAL CABINETS: Dimensions (WxDxH): 680x800x1800 mm 1100x800x1800 mm 1. Rectifier and/or bypass transformer 1550x800x1800 mm (150 – 200 kVA) (250 – 300 kVA) (150 – 200 kVA) (250 – 300 kVA) th 2. 5 harmonic filter 3. 12 pulse rectifier without galvanic separation 4. 12 pulse rectifier with galvanic separation th th th th 5. Distortion Control Unit (DCU) with dynamic filtering of 5 , 7 , 11 , 13 harmonics th th 6. Distortion Control Unit (DCU) “Light” with filtering of 11 and 13 harmonics (Only in combination with 12 pulse rectifier) 7. Special voltages: input and/or output 8. Centralized maintenance bypass for RPA configuration 9. Empty battery cabinets On request On request External accessories: 1. External battery fuses box Modifications reserved TDS_SPE_XXX_M15_M30_6GB_V060.doc On request Page 4/5 Technical Data Sheets SitePro 150-200-250-300 kVA TECHNICAL DATA SitePro 250 & 300 kVA SitePro 150 & 200 kVA UPS weight Floor loading 150 kVA 925 Kg 1050 Kg/m2 200 kVA 995 Kg 1130 Kg/m2 250 kVA 1450 Kg 1170 Kg/m2 300 kVA 1550 Kg 1250 Kg/m2 UPS BLOCK DIAGRAM, PROTECTIONS AND CABLE SECTIONS Separated input Rectifier & Bypass (recommended) 1 Rectifier 2 Inverter 3 Electronic Bypass 4 Manual Bypass 5 Mains 6 Load 7 External Battery F4 External Battery Fuses Common input Rectifier & Bypass Protections and cable sections Cable sections A, B, C, D, E, K Recommended by European Standards Alternatively, local standards to be respected Protections for mains voltages 3x380/220V, 3x400/230V, 3x415/240V 2 Fuses AgL or equivalent MTCB kVA 150 200 250 300 F1 3 x 315 A 3 x 400 A 3 x 500 A 3 x 630 A F2 3 x 250 A 3 x 315 A 3 x 400 A 3 x 500 A F3 3 x 315 A 3 x 400 A 3 x 500 A 3 x 630 A F4 (battery) 2 x 400 A 2 x 500 A 2 x 630 A 2 x 800 A Cable sections (mm ) A B C/E D K 3 x 150 + 95 4 x 120 4 x 150 + 70 4 x 120 + 70 2 x 240 + 120 3 x 240 + 120 4 x 150 4 x 240 + 120 4 x 150 + 95 2 (2x120) + 120 3 (2x120) + 120 4 x 240 4 (2x120) + 120 4 x 240 + 120 2 (2x150) + 150 3 (2x150) + 150 4 (2 x 120) 4 (2x150) + 150 4 (2x120) + 120 2 (2x240) + 240 SEV/ASE cable sections recommended in Switzerland (mm2) kVA A B C/E D 150 3 x 185 + 95 200 3 (2x95) + 95 K 4 x 150 4 x 185 + 95 4 x 150 + 95 2 (2x95) + 95 4 x 185 4 (2x95) + 95 4 x 185 + 95 2 (2x150) + 150 4 (2x95) 4 (2x150) + 150 4 (2x95) + 95 2 (2x185) + 185 F1, F2, F3, A, B, C, D, E: supplied by customer. 250 3 (2x150) + 150 F4: can be supplied by GE. 300 3 (2x185) + 185 4 (2 x 150) 4 (2x185) + 185 4 (2x150) + 150 2 (3x185) + 2x150 Modifications reserved TDS_SPE_XXX_M15_M30_6GB_V060.doc Page 5/5 Technical Data Sheets SitePro 150-200-250-300 kVA
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement