Section 5 Dedicated Timers - Spec

Section 5 Dedicated Timers - Spec
Section 5
Dedicated Timers
De
d
tim icat
er ed
s
Note: DIN Rail Mounting Product pages are not included in this catalog.
Go to: www.ssac.com/sg5.pdf
Click on the Product Name
(ie: CT-SDS) to open the catalog page.
[Adobe Acrobat Reader is required]
Single Function
Delay on Make (ON Delay)
Relay Output...................................... 5.2
Solid State Output............................. 5.16
DIN Rail Mounting............see Note above
Single Shot, Retriggerable
(Watchdog, Zero Speed)
Relay Output.............................................5.96
DIN Rail Mounting....................see Note Above
Delay on Make, Normally Closed
Trailing Edge Interval
Solid State Output............................. 5.34
DIN Rail Mounting................... see Note Above
Delay on Break (OFF Delay)
Interval (Impulse ON)
Relay Output...................................... 5.42
Solid State Output............................. 5.54
DIN Rail Mounting............see Note above
Relay Output.............................................5.100
Solid State Output....................................5.108
DIN Rail Mounting.................... see Note above
True Delay on Break (without auxiliary voltage)
Recycling & Percentage
Relay Output....................see Note above
Solid State Output...........see Note above
Relay Output.............................................5.126
Solid State Output....................................5.138
Single Shot (Pulse Former)
Recycling Flashers
Relay Output...................................... 5.70
Solid State Output............................. 5.84
DIN Rail Mounting.................... see Note above
Sequencer
SQ3 & 4 -- Solid State Output..................5.154
Dual Function
Delay on Make/Delay on Break
TDMB -- Plug-In........................................5.156
DIN Rail Mounting
CT-MXS.xx ............................. see Note above
Delay on Make/Interval
ESD5 -- Solid State...................................5.158
HVAC Timers
Solid State Output
TAC1 -- Anti Short Cycle Random Start...5.160
T2D -- Anti Short Cycle, Random Start....5.162
TAC4 -- Bypass Timing.............................5.164
TA -- Anti Short Cycle (DOB).....................5.166
TL -- Anti Short Cycle (DOB).....................5.168
CT -- Fan Delay.........................................5.170
Vending Timers
HRV -- Relay Output.................................5.172
THC/THS -- Solid State Output................5.94
KSPU -- Solid State Output......................5.176
NHPU -- Solid State Output.....................5.178
Star Delta Motor Starting
Din Rail Mounting
CT-SDS....................................see Note above
CT-SDE ...................................see Note above
CT-YDE....................................see Note above
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com
5.1
1TRC 001 009 C0202
Coin Vending Timer
HRV Accu-Vend
Vending Control
ed
at
c
i
d
rs
De time
Description
The HRV combines the accuracy of microcontroller based circuitry with an electromechanical relay output.
The HRV’s switching capacity allows direct control of loads like compressors, pumps, motors, heaters, and
lighting. The HRV “S” version provides a vend time after the selected number of initiate switch closures to
start is reached. The HRV “A” version includes all of the “S” features and allows the total vend time to be
extended for each additional initiate switch closure. The HRV is ideal for cost sensitive single coin or token
vending machines. The electronic circuitry is encapsulated to protect against humidity and vibration.
Operation
US Patent 6708135
Accumulates 1 ... 256 Coins
Switch Selectable 1 ... 7
Coins to Start
Vend Time from
1 s ... 31.75 m
Coin Switch Can Be
Connected to a Counter
Up to 30 A, 1 Hp at
125 V AC N.O. Contacts
Encapsulated Circuitry
Approvals:
Coin Totalizer & Vending Timer (“S” Version):
Input voltage must be applied prior to & during
operation. When the total number of S1 initiate switch
closures equals the number to start set on the lower 3
DIP switches, the load energizes and the vending time
set on the upper 7 DIP switches begins. At the end of
the vending time, the load de-energizes and the vending
time is reset. Closing the initiate switch during vend
timing will have no affect on vend time delay.
Accumulating Vending Timer (“A” Version):
Input voltage must be applied prior to & during
operation. When the total number of S1 initiate switch
closures equals the number to start set on the lower 3
DIP switches, the load energizes and the vending time
starts. For every initiate switch closure, the HRV unit
adds one time per coin period, as set on the upper 7
DIP switches, to the total vending time.
Operation Note: If S1 is closed when input voltage is
applied, the output remains de-energized and the S1
counter remains at zero closures. At least one “vend
time” and one “closures to start” DIP switch must be in
the “ON” position for proper operation.
Reset: Removing input voltage resets the vend time
delay, the S1 closure counter, and de-energizes the
output relay.
Connection
Isolated Output
Non-Isolated
Output
V = Voltage S1 = Initiate Switch L = Load
UTL = Optional Untimed Load
Accessories
Mounting bracket
P/N: P1023-6
Function
Coin Totalizer & Vending Timer
Accumulating Vending Timer
Female quick
connect P/Ns:
P1015-64 (AWG 14/16)
P1015-13 (AWG 10/12)
Ordering Table
HRV
Series
DIN rail P/Ns:
017322005 (Steel)
C103PM (Al)
←
X
Input
–1 - 12 V DC
–2 - 24 V AC
–3 - 24 V DC
–4 - 120 V AC
–6 - 230 V AC
X
Vend Time
–1 1 ... 127 s
–2 5 ... 635 s
–3 - 0.1 .. 12.7 m
–4 - 0.25 .. 31.75 m
→
DIN rail adaptor
P/N: P1023-20
X
Mode of Operation
–S - Coin Totalizer
Vending Timer
–A - Accumulating
Vending Timer
X
Output Form &
Rating
–C - 30 A SPDT-N.O.
(Isolated)
–E - 30 A SPDT-N.O. (Isolated)
–N - 30 A SPDT-N.O. (Non-Isolated)
Example P/N: HRV43SC, HRV62AN
5.172
1TRC 001 009 C0202
HRVGen
See accessory pages for
specifications.
08.16.04
Quick connect to
screw adaptor
P/N: P1015-18
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com
De
Coin Vending Timer
HRV Accu-Vend
Vending Control
d
tim icat
er ed
s
Technical Data
Count Functions/Switch Type
Mechanical (counts on switch closure)
Minimum Switch Closure Time
≥ 20 ms
Minimum Switch Open (between closures) Time ≥ 20 ms
Count Range to start
1 ... 7 counts
Maximum Counts ("A" Version)
250
Time Delay/Range ***
Adjustable 1 s ... 31.75 m in 4 ranges
Adjustment
7 of a 10 position DIP switch
Setting Accuracy
− 0 to +2% or 50 ms, whichever is greater
Repeat Accuracy
+/-0.1% or 20 ms, whichever is greater
Reset Time
≤ 150 ms
Time vs. Input Voltage & Temperature
≤ +/-2%
Input
Voltage/Frequency
12 or 24 V DC; 24, 120, or 230 V AC/50 ... 60 Hz
Tolerance
12 V DC & 24 V DC/AC
-15% ... +20%
120 & 230 V AC
-20% ... +10%
DC Ripple
≤ 10%
Power Consumption
AC: ≤ 4 VA; DC: ≤ 2 W
Output
TypeElectromechanical relay
Form
Isolated SPDT or Non-isolated SPDT
Ratings:
SPDT-N.O.
SPDT-N.C.
General Purpose
125/240 V AC
30 A
15 A
Resistive
125/240 V AC
30 A
15 A
28 V DC
20 A
10 A
Motor Load
125 V AC
1 hp*
1/4 hp**
240 V AC
2 hp**
1 hp**
LifeMechanical -- 1 x 106
Electrical -- 1 x 105, *3 x 104, ** 6,000
Protection
SurgeIEEE C62.41-1991 Level A
Circuitry
Encapsulated
Dielectric Breakdown≥ 1500 V RMS input to output on isolated units
Insulation Resistance≥ 100 MΩ Mechanical
Mounting
Surface mount with one #10 (M5 x 0.8) screw
Package
3 x 2 x 1.5 in (76.7 x 51.3 x 38.1 mm)
Termination
0.25 in. (6.35 mm) male quick connect terminals
Environmental
Humidity95% relative, non-condensing
Operating/Storage Temperature-40°C ... +70°C / -40°C ... +85°C
Weight≅ 3.9 oz (111 g)
***For CE approved applications, voltage must be removed when a switch position is changed.
Switch Adjustment
Mechanical View
Combine upper seven switches
in “ON” position for vend time in
minutes.
Combine lower three switches
in “ON” position for number of
closures to start.
Example Setting: Range 3 - 1.2 minutes per coin
- 1 coin to start.
HRVGen
Inches (Millimeters)
08.16.04
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com
5.173
1TRC 001 009 C0202
Single Shot (Pulse Former)
THC & THS Series
Power Timing Module
ed
at
c
i
d
rs
De time
Description
The TH series is a solid state relay and timer combined into one compact, easy-to-use control. When mounted
to a metal surface, the TH Series may be used to directly control lamp or heater loads of up to 20 Amps steady
200 Amps inrush. Its single shot function can perform dispensing and pulse shaping operations. The initiate
switch can be a momentary or maintained type of switch. Time delays can be selected from 0.1 seconds to
600 seconds in 4 ranges. The THC Series is used for coin vending applications where fast initiate response
is required.
Operation
High Load Current Capacity,
up to 20 A, 200 A Inrush
Momentary or Maintained
Initiate Switch
+/-2% Repeat Accuracy
+/-5% Factory Calibration
Fixed or Adjustable Delays
From 0.1 ... 600 s in 4
Ranges
Metallized Mounting Surface
for Efficient Heat Transfer
Input voltage must be applied before and during timing.
Upon momentary or maintained closure of the initiate
switch (leading edge triggered), the output energizes for
a measured interval of time. At the end of the delay, the
output de-energizes. Opening or reclosing the initiate
switch during timing has no affect on the time delay.
The output will energize if the initiate switch is closed
when input voltage is applied.
Reset: Reset occurs when the time delay is complete
and the initiate switch opens. Loss of input voltage
resets the time delay and output.
Function
Single Shot
V = Voltage L = Load S1 = Initiate Switch
TD = Time Delay R = Reset
Approvals:
Connection
Accessories
External adjust
potentiometer
P/Ns:
P1004-95 (fig A)
P1004-95-X (fig B)
Female quick
connect
P/Ns:
P1015-64 (AWG 14/16)
P1015-13 (AWG 10/12)
Quick
connect to
screw adaptor
P/N: P1015-18
Versa-knob
P/N: P0700-7
See accessory pages for
specifications.
5.174
1TRC 001 009 C0202
RT is used when external adjustment is ordered.
Dashed lines are internal connections.
S1 = Initiate Switch L = Timed Load
UTL = Optional Untimed Load
Ordering Table
THC/
THS
Series
X
Input
–2 - 24 V AC
–4 - 120 V AC
–6 - 230 V AC
X
Adjustment
–1 - Fixed
–2 - External
Adjust
–3 - Onboard Adjust
Example P/N: THC432C Fixed – THC612A
THS421B Fixed – THS410.5C
X
Time Delay *
–1 - 0.1 ... 3 s
–2 - 0.5 ... 60 s
–3 - 2 ... 180 s
–4 - 5 ... 600 s
X
Output Rating
–A - 6 A
–B - 10 A
–C - 20 A
07.28.04
A
*If Fixed Delay is selected, insert
delay [0.1...600] in seconds.
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com
THSGen2
B
De
Single Shot (Pulse Former)
THC & THS Series
Power Timing Module
d
tim icat
er ed
s
Technical Data
Time Delay
Range
Repeat Accuracy
Tolerance (Factory Calibration)
Reset Time
Initiate Time
Time Delay vs. Temperature & Voltage
Input
Voltage
Tolerance
Line Frequency
Power Consumption
Output
Type
Form
Maximum Load Currents
Minimum Load Current
Voltage Drop
OFF State Leakage Current
Protection
Circuitry
Dielectric Breakdown
Insulation Resistance
Mechanical
Mounting **
Package
Termination
Environmental
Operating Temperature
Storage Temperature
Humidity
Weight
0.1 ... 600 s in 4 adjustable ranges or fixed
+/-2% or 20 ms, whichever is greater
≤ +/- 5%
≤ 150 ms
≤ 20 ms
≤ +/-10%
24, 120, or 230 V AC
+/-15%
50 ... 60 Hz
≤ 2 VA
Solid state
Normally Open, closed during timing
Output
Steady State Inrush**
A
6 A
60 A
B
10 A
100 A
C
20 A
200 A
100 mA
≅ 2.5 V at rated current
≅ 5 mA at 230 V AC
**Must be bolted to a metal surface using the
included heat sink compound. The maximum
mounting surface temperature is 90°C. Inrush:
Non-repetitive for 16 ms.
Encapsulated
≥ 2000 V RMS terminals to mounting surface
≥100 MΩ
Surface mount with one #10 (M5 x 0.8) screw
2 x 2 x 1.51 in. (50.8 x 50.8 x 38.4 mm)
0.25 in. (6.35 mm) male quick connect terminals
-20°C ... +60°C
-40°C ... +85°C
95% relative, non-condensing
≅ 3.9 oz (111 g)
Mechanical View
Fixed & External Adjust
Onboard Adjust
THSGen2
07.28.04
Inches (Millimeters)
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com
5.175
1TRC 001 009 C0202
ProgramaCube
KSPU Series
Timing Module
ed
at
c
i
d
rs
De time
Description
The KSPU Series is a factory programmed module available in any 1 of 14 standard functions. The KSPU
offers a single adjustable timer or counter function. Modules are manufactured without the function assigned.
When an order is received, the function software is added. This approach provides fast delivery on all part
numbers. Switch adjustment allows accurate selection of the time delay or number of counts the first time
and every time. The 1 A steady, 10 A inrush rated solid state output provides 100 million operations, typical.
Its microcontroller timing circuit provides excellent repeat accuracy and stability. Encapsulation protects
against shock, vibration, and humidity. The KSPU Series is a cost effective approach for OEM applications that
require small size, solid state reliability, and accurate switch adjustment. Special time ranges and functions
are available; contact Technical Assistance (see below) for more information.
Connection
US Patent 6708135
Choose 1 of 14 Standard
Functions
Special Time Ranges and
Functions Available
Factory Programmed
Microcontroller Circuitry,
+/-0.1% Repeat Accuracy
Solid State Output 1 A Steady, 10 A Inrush
Accurate Switch Adjustment
12 ... 240 V in 3 Ranges
Delays from 100 ms...1023 h in 6 ranges
Counts to 1023 in 3 Ranges
(For Negative Switching)
(For Positive Switching)
Inches (Millimeters)
V = Voltage S1 = Initiate Switch
L = Load UTL = Untimed Load
The untimed load is optional. S1 is not used for some
functions. Dashed lines are internal connections.
Switch Adjustment
Accessories
Female quick
connect
P/Ns:
P1015-64 (AWG 14/16)
P1015-14 (AWG 18/22)
DIN rail P/Ns:
017322005 (Steel)
C103PM (Al)
←
→
One or more switches must be ON for proper operation.
5.176
1TRC 001 009 C0202
M
B
RE
RD
S, SD
I
TS
US
UB
AM
PSD
C
CI
For a Complete List of Functions with Descriptions,
see Timer Function Section.
Ordering Table
KSPU
Series
X
Input
– A - 24 ... 240 V AC
– P - 12 ... 120 V DC
Positive Switching
– N - 12 ... 120 V DC
Negative Switching
DIN rail adaptor
P/N: P1023-20
See accessory pages for
specifications.
Code
X
X
Time Delay/Counts
Function**
– 1 - 0.1 ... 102.3 s
–Specify Function
– 2 - 1 ... 1023 s
(Refer to Function
Chart for Code)
– 3 - 0.1 ... 102.3 m
– 4 - 1 ... 1023 m
– 5 - 0.1 ... 102.3 h
– 6 - 1 ... 1023 h
– 7 - 1 ... 165 counts (straight) w/pulsed output
– 8 - 1 ... 1023 counts (binary) w/pulsed output
– 9 - 1 ... 7 counts to start 1 ... 63 s or m interval time
Example P/N: KSPUA2RE
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com
06.06.05
Quick connect to
screw adaptor
P/N: P1015-18
**Function Chart
Delay on Make
Delay on Break
Recycle (ON Time First, Equal Times) Recycle ( OFF Time First, Equal Times)
Single Shot
Interval
Trailing Edge Single Shot
Inverted Single Shot
Inverted Delay on Break
Accumulative Delay on Make
Motion Detector/Retriggerable
Single Shot Counter/Pulsed Output
Counter/Interval Output
KSPUGen
Approvals:
Mechanical View
ProgramaCube
KSPU Series
Timing Module
De
d
tim icat
er ed
s
Technical Data
Time Delay
Type
Range
Microcontroller circuitry
0.1 ... 102.3 s, m or h in 0.1 s, m or h increments
1 ... 1023 s, m or h in 1 s, m or h increments
1 ... 63 s or m in 1 s or m increments
+/-0.1% or 20 ms, whichever is greater
≤ +/-1% or 20 ms, whichever is greater
≤ 150 ms
≤ 20 ms
≤ +/-2%
1 ... 1023 in 3 ranges
≤ 25 counts per second
Repeat Accuracy
Setting Accuracy
Reset Time
Initiate Time
Time Delay / Temp. & Voltage Count Range
Count Rate
Input
Voltage
12 ... 120 V DC; 24 ... 240 V AC
Tolerance
≤ +/-15%
Frequency/DC Ripple
50 ...60 Hz / ≤ 10%
Power Consumption
AC ≤ 2 VA; DC ≤ 1 W
Output
Type
Solid state output
Rating
1 A steady, 10 A inrush for 16 ms
Voltage Drop
AC ≅ 2.5 V at 1 A; DC ≅ 1 V at 1A
OFF State Leakage Current AC ≅ 5 mA at 240 V AC; DC ≅ 1mA
Counter Output
Output Pulse width: 300 ms +/-20%
(P/N Variable 7 & 8)
Function Diagrams
M
B
Protection
Circuitry
Dielectric Breakdown
Insulation Resistance
Polarity
Encapsulated
≥ 2000 V RMS terminals to mounting surface
≥ 100 MΩ
DC units are reverse polarity protected
Mechanical
Mounting
Package
Termination
Surface mt. with one #10 (M5 x 0.8) screw
2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
0.25 in. (6.35 mm) male quick connects
Environmental
Operating Temp.
Storage Temp.
Humidity
Weight
-40°C ... +60°C
-40°C ... +85°C
95% relative, non-condensing
≅ 2.4 oz (68 g)
For a Complete List of Functions with Descriptions, see Timer Function Section.
S
Delay On Make
Delay On Break
SD
RE
Recycling (ON First)
I
RD
Recycling (OFF First)
TS
KSPUGen
Note: If S1 is closed when input
voltage is applied, the function
starts and the time delay begins.
(B, S, TS, US, UB, AM, PSD, C, CI)
US
06.06.05
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com
Single Shot
Operates same as S except will not
energize and start timing if initiate
switch is closed when input voltage
is applied.
Interval
Trailing Edge Single Shot
UB
Inverted Delay On Break
AM
Accumulative Delay On Make
PSD
Motion Detector
Retriggerable Single Shot
C/CI
Counter with Pulsed Output
Counter with Interval Output
Legend
Inverted Single Shot
V
R
S1
L TD,TD1, TD2
t
Voltage
Reset
Initiate Switch
Output & Load
Time Delay
Incomplete Time Delay
Undefined time
5.177
1TRC 001 009 C0202
ProgramaCube
NHPU Series
Power Timing Module
ed
at
c
i
d
rs
De time
Description
The NHPU Series is a factory programmed module available in any 1 of 14 standard functions. The NHPU offers
a single adjustable timer or counter function. Modules are manufactured without the function assigned. When
an order is received, the function software is added, making the modules complete. This approach provides fast
delivery on all part numbers. Switch adjustment allows accurate selection of the time delay or number of counts,
the first time and every time. The NHPU includes a high current solid state output. It can switch motors, lamps
and heaters directly without the addition of a contactor. It can switch up to 20 A with up to 100 million operations,
typical. Its microcontroller timing circuit provides excellent repeat accuracy and stability. Encapsulation protects
against shock, vibration, and humidity. The NHPU Series is a cost effective approach for OEM applications that
require small size, solid state reliability, and accurate switch adjustment. Special time ranges and functions are
available; contact Technical Assistance (see below) for more information.
Mechanical View
V = Voltage L = Load
UTL = Untimed Load S1 = Initiate Switch
Inches (Millimeters)
The untimed load is optional. S1 is not used for some
functions. Dashed lines are internal connections.
Approvals:
Accessories
Female quick connect
P/Ns:
P1015-13 (AWG 10/12)
P1015-64 (AWG 14/16)
P1015-14 (AWG 18/22)
Quick connect to
screw adaptor
P/N: P1015-18
See accessory pages for
specifications.
5.178
1TRC 001 009 C0202
**Function Chart
Code
Delay on Make
Delay on Break
Recycle (ON Time First, Equal Times)
Recycle ( OFF Time First, Equal Times)
Single Shot
Interval
Trailing Edge Single Shot
Inverted Single Shot
Inverted Delay on Break
Accumulative Delay on Make
Motion Detector/Retriggerable
Single Shot
Counter/Pulsed Output
Counter/Interval Output
Switch Adjustment
One or more switches must be ON for proper operation.
M
B
RE
RD
S, SD
I
TS
US
UB
AM
PSD
C
CI
For a Complete List of Functions with
Descriptions, see Timer Function Section.
Ordering Table
NHPU
Series
X
Output/
Rating
–A - 6 A
–B - 10 A
–C - 20 A
X
Input
–A - 24 ... 240 V AC
X
X
Time Delay/Counts
Function**
–1 - 0.1 ... 102.3 s
–Specify Function
–2 - 1 ... 1023 s
(Refer to Function
–3 - 0.1 ... 102.3 m
Chart for Code)
–4 - 1 ... 1023 m
–5 - 0.1 ... 102.3 h
–6 - 1 ... 1023 h
–7 - 1 ... 165 counts (straight) w/pulsed output
–8 - 1 ... 1023 counts (binary) w/pulsed output
–9 - 1 ... 7 counts to start 1 ... 63 s or m interval time
06.15.05
High Load Currents up to
20 A, 200 A Inrush
Factory Programmed
Choose 1 of 14 Standard
Functions
Special Time Ranges and
Functions Available
Microcontroller Circuitry,
+/-0.1% Repeat Accuracy
Accurate Switch Adjustment
24 ... 240 V AC
Delays from 100 ms...1023 h
in 6 Ranges
Counts to 1023 in 3 Ranges
Connection
NHPUGen
US Patent 6708135
Example P/N: NHPUBA3TS, NHPUCA7C
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com
ProgramaCube
NHPU Series
Power Timing Module
De
d
tim icat
er ed
s
Technical Data
Time Delay
Type
Range
Microcontroller circuitry
0.1 ... 102.3 s, m or h in 0.1 s, m or h increments
1 ... 1023 s, m or h in 1 s, m or h increments
1 ... 63 s or m in 1 s or m increments
Repeat Accuracy
+/-0.1% or 20 ms, whichever is greater
Setting Accuracy
≤ +/-1% or 20 ms, whichever is greater
Reset Time ≤ 150 ms
Initiate Time
≤ 20 ms
Time Delay vs. Temp. & Voltage ≤ +/-2%
Count Range
1 ... 1023 in 3 ranges
Count Rate
≤ 25 counts per second
Input
Voltage
24 ... 240 V AC
Tolerance
≤ +/-15%
Line Frequency
50 ... 60 Hz
Output
Type
Solid state
Rating
Output
Steady State
Inrush***
A
6A
60 A
B
10 A
100 A
C
20 A
200 A
Minimum Load Current
100 mA
Voltage Drop
≅ 2.5 V at 1 A
OFF State Leakage Current
≅ 5 mA at 230 V AC
Counter Output
(P/N Variable 7 & 8)
Pulse width: 300 ms +/-20%
Function Diagrams
M
B
Delay On Make
Protection
Circuitry
Encapsulated
Dielectric Breakdown ≥ 2000 V RMS terminals to mounting surface
Insulation Resistance ≥ 100 MΩ
Mechanical
Mounting ***
Package
Termination
Environmental
Operating Temp. Storage Temp.
Humidity
Weight -40°C ... +60°C
-40°C ... +85°C
95% relative, non-condensing
≅ 3.9 oz (111 g)
***Must be bolted to a metal surface
using the included heat sink compound.
The maximum mounting surface temperature is 90°C. Inrush: Non-repetitive
for 16 ms.
For a Complete List of Functions with Descriptions, see Timer Function Section.
S
UB
Inverted Delay On Break
Single Shot
Delay On Break
SD
I
RE
Operates same as S except will not
energize and start timing if initiate
switch is closed when input voltage
is applied.
Interval
Recycling (ON First)
RD
Surface mt. with one #10 (M5 x 0.8) screw
2 x 2 x 1.51 in. (50.8 x 50.8 x 38.4 mm)
0.25 in. (6.35 mm) male quick connects
Recycling (OFF First)
NHPUGen
Note: If S1 is closed when input
voltage is applied, the function
starts and the time delay begins.
(B, S, TS, US, UB, AM, PSD, C, CI)
06.15.05
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • Technical assistance 800-377-7722 • www.ssac.com
TS
Trailing Edge Single Shot
AM
Accumulative Delay On Make
PSD
C/CI
Motion Detector
Retriggerable Single Shot
Counter with Pulsed Output/
Counter with Interval Output
US
Inverted Single Shot
Legend
V
R
S1
L
TD,TD1, TD2
t
Voltage
Reset
Initiate Switch
Output & Load
Time Delay
Incomplete Time Delay
Undefined time
5.179
1TRC 001 009 C0202
Publication SS3
No. 1TRC001009C0202
Printed in USA, January, 2007
Sales Information:
ABB Inc.
1206 Hatton Road
Wichita Falls, TX 76302
Telephone 888-385-1221; 940-397-7000
Fax 940-397-7085
http://www.abb-control.com
Technical Help and Product Support
ABB Inc.
Telephone 315-638-1300
Technical Help 800-377-SSAC (7722)
Fax 315-638-0333
http://www.ssac.com
Sales Information (Canada)
ABB Inc.
2105 32nd Avenue
Lachine, Quebec H8T 3J1
Canada
Telephone
Atlantic & Quebec Region: 800-567-0203
Ontario Region: 866-460-3300
Mid-West & Pacific Region: 866-222-8368
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement