Engineer`s Desktop™ Software Version 5000.1.7.0

Add to my manuals
423 Pages

advertisement

Engineer`s Desktop™ Software Version 5000.1.7.0 | Manualzz
Engineer’s Desktop™
Software Version 5000.1.7.0
Release Notes
Contents
2
Introduction To Engineer’s Desktop™ ..................................................................
3
System Requirements ............................................................................................
14
Third-Party Software ...............................................................................................
24
Other Requirements ...............................................................................................
27
Before You Install ....................................................................................................
31
Installation: 32-Bit Operating Systems .................................................................
35
Installation: 64-Bit Operating Systems .................................................................
45
Licensing .................................................................................................................
63
Enhancements, Fixed Issues, and Known Issues ...............................................
65
International Trade Compliance ............................................................................ 416
Contacting Landmark Customer Support ............................................................ 418
5000.1.7
May 2010
Draft
What’s In This Release? .........................................................................................
What’s In This Release?
EDT™ Software Release Notes
What’s In This Release?
The 5000.1.7 update release of the Engineer’s Desktop™ (EDT™) suite of products
provides major usability enhancements and bug fixes for OpenWells. There are bug fixes
only for the following applications: PROFILE, COMPASS, WELLCAT, Well Cost,
WELLPLAN, and StressCheck. The EDM data model has been modified to support the
changes to these applications, and the installation has also been modified.
The supported platforms were updated in the 5000.1.3 release. Descriptions of
Enhancements, Fixed Problems, and Known Issues for each application in the EDT suite
are provided.
Draft
To go directly to the enhancements, bug fixes, and known issues for individual
applications, click on the blue links below:
CasingSeat™
Enhancements
Fixed Issues
Known Issues
COMPASS™
Enhancements
Fixed Issues
Known Issues
Data Analyzer™
Enhancements
Fixed Issues
Known Issues
EDM™
Enhancements
Fixed Issues
Known Issues
Engineer’s Desktop™
(EDT™)
Integration
Enhancements
Integration
Fixed Issues
Integration
Known Issues
OpenWells®
Enhancements
Fixed Issues
Known Issues
PROFILE™
Enhancements
Fixed Issues
Known Issues
Real-Time View™
Enhancements
Fixed Issues
Known Issues
StressCheck™
Enhancements
Fixed Issues
Known Issues
WELLCAT™
Enhancements
Fixed Issues
Known Issues
Well Cost™
Enhancements
Fixed Issues
Known Issues
WELLPLAN™
Enhancements
Fixed Issues
Known Issues
An Introduction to the Engineer’s Desktop release, System Requirements, Installation
Instructions, and Licensing for all products is also covered in this document.
5000.1.7
Page 2 of 423
May 2010
Introduction To Engineer’s Desktop™
EDT™ Release Notes
Go To “What’s In This Release?”
Introduction To Engineer’s Desktop™
Welcome to the 5000.1.7 update release of the 5000.1.0 version of Engineer's Desktop™
(EDT™) software. The Windows-based Engineer’s Desktop software enables the Drilling
& Completions applications—Well Engineering, Tubular Design, and Well Data
Management—to run on a shared data model.
Engineer’s Desktop software contains the following application areas:
•
Engineer's Data Model™ software—EDM Administration Utility, SQL Server Utility,
Drilling and Well Services Data Migration
•
Drilling Engineering—CasingSeat™, COMPASS™, StressCheck™, WELLPLAN™,
WELLCAT™, and Well Cost™ applications
•
Data Management—OpenWells®, Data Analyzer™, PROFILE™, and Real-Time
View™ applications.
EDT release 5000.1.7 update is installed via a WinZip® file obtained via the Electronic
Software Delivery system, using Landmark Software Manager.
IMPORTANT:
•
EDT 5000.1.7 software is an update release of 5000.1.0 and higher. If you are currently using
an EDM database version that is 2003.14 through 5000.0.0, you must first install EDT 5000.1.0 and
then upgrade your database using the new Multi-Version Database Upgrade Utility
(EDMPatchDB.exe) before installing the 5000.1.7 upgrade. Refer to the EDT™ Version 5000.1.0
Summary Level Release Notes for complete details on installing and upgrading to 5000.1.0.
•
EDT 5000.1.7 applications can co-exist with previous versions of EDT applications on the same
machine with no issues. To run EDT 5000.1.7 and a 2003.x version of EDT on the same machine,
you must point one or both versions of EDT software to a LAM server located on a remote
machine, since only one LAM server can run locally. LAM 2003 and LAM 5000 cannot run on the
same machine.
The following sections of this document provide more information about the Engineer’s
Desktop release and the enhancements, issues fixed and known issues for releases
5000.1.0 through 5000.1.7. Contact your Landmark Sales or Support Representative for
further information on upcoming EDT release plans.
5000.1.7
Page 3 of 423
May 2010
Draft
The function of the 5000.1.7 update release is to provide major usability enhancements
and bug fixes for the OpenWells application. There are bug fixes only for the following
applications: PROFILE, COMPASS, WELLCAT, Well Cost, WELLPLAN, and
StressCheck. The EDM data model has been modified to support the changes to these
applications, and the installation has also been modified.
Introduction To Engineer’s Desktop™
EDT™ Release Notes
Go To “What’s In This Release?”
Applications Included in the Engineer’s Desktop Software Release
The WinZip® Patch Installer will install WELLCAT™ software (new in EDT for the
5000.1.3 release) and will overwrite all Engineer’s Desktop 5000.1.0 and higher files
installed on your system with the 5000.1.7 versions of the files. Files that did not exist will
be created.
All of the EDT software applications in the release are described briefly below. They are
grouped into three natural combinations:
Engineer’s Data Model
•
Drilling Engineering
•
Data Management
Draft
•
Engineer’s Data Model Applications
EDM Database
EDM (Engineer’s Data Model) is Landmark’s newest integrated database product.
This release of Engineer’s Desktop enables the migration of legacy data from
COMPASS, WELLPLAN, and DIMS applications into the new common database.
CasingSeat and StressCheck applications can directly import legacy data files.
Common data from each legacy database can be merged into one set of shared
business objects, preventing future duplication of information.
Click here to view the EDM enhancements, fixed issues, and known issues for
5000.1.7.
The EDM database allows for centralization of Drilling application data sets and
enables naturally integrated engineering workflows. Integrated workflows are
available between Drilling applications.
EDM AutoSync Server and EDM AutoSync Client (available separately from LSM)
Available separately from Landmark Software Manager are the 5000.1.5 versions
of EDM AutoSync Server and EDM AutoSync Client. These applications provide
bi-directional updates between Rig and Regional EDM databases. By ensuring the
AutoSync Client application from the Rig is updating the Regional database, these
changes can be automatically pushed to the Corporate database by AutoSync
Server.
5000.1.7
Page 4 of 423
May 2010
Introduction To Engineer’s Desktop™
EDT™ Release Notes
Go To “What’s In This Release?”
The synchronization process is truly bi-directional in that the Regional office can
send any changes to wells under AutoSync control to the Rig upon
synchronization. Only data that is changed is transmitted. Additionally, Rigs may
choose to accept Read Only Control to be kept aware of changes to a well at the
Regional level.
Regional offices updated with OpenWells 5000.1.5 can make direct well
assignments to the AutoSync Client. Otherwise, the EDM Administrator can assign
permissions to an AutoSync Client user to browse the connected database and
select wells to be placed under AutoSync Control.
EDM™ AutoSync Server software is an application that supports database
synchronization of versions 2003.16.1.15 and higher, and 5000.1.0 and higher of
the shared EDM™ data model. AutoSync Server software is installed on a machine
running Windows 2003 or 2008 Server. Windows Vista servers are not supported.
EDM™ AutoSync Client software runs on Windows XP or Windows Vista 32-bit or
64-bit platforms.
Catalog Editor
(Drilling) Catalogs are used as equipment selection lists to design a casing, tubing,
liner, or drillstring. Read-only system catalogs are distributed with the software.
Additional custom catalogs can be created that will allow changes. A catalog can
be copied and pasted (including read-only catalogs); copied catalogs are editable
and can be customized. Custom catalogs are useful because the catalog content
can be customized to the available pipes or other drilling products used by the
company. A catalog can be locked to prevent changes. You can also merge
catalogs.
The Catalog Editor application allows you to edit the catalog selected in the Well
Explorer.
Rig Editor
The Rig Editor utility allows you to enter information regarding the identity and
properties of the rig, derrick, related equipment, and capacities. In the WELLPLAN,
StressCheck, and CasingSeat applications, this utility opens when you right-click
5000.1.7
Page 5 of 423
May 2010
Draft
AutoSync Server addresses the problem of discrepancies in data updates between
the Rig and the Regional Office and determines whose data to keep by way of
policies set at the Regional level. These policies are configurable by EDM
Administrators to conform to company policies. Several policy templates are
provided as starting points; configurations may be saved and imported to apply to
new Rig connections.
Introduction To Engineer’s Desktop™
EDT™ Release Notes
Go To “What’s In This Release?”
on a contractor. COMPASS software users can enter rig information by selecting
Rig Editor from the Start > Landmark Engineer’s Desktop 5000.1 > Tools menu. In
the OpenWells application, rig and contractor information can be modified in the
Contractor’s tab of the Well Explorer.
Unit Converter
Use the Unit Converter application to convert a numeric value from one unit
measurement system to an equivalent unit measurement system based on unit
types (categories) defined in the database.
Field Office Data Transfer (Drilling)
The Field Office Data Transfer application is used to transfer the database
hierarchy, wells, wellbores, events, and reports between EDM databases. It also
has an option to import and export site and picklist metadata information. Data can
be sent through the LAN or through Dial Up Networking. Data can be transferred
through email or FTP. Two Windows Services must be run in the background for
the receiving EDM database: Email Watcher, and Data Receiver. A dedicated PC
is normally used for this purpose.
Email Watcher scans the recipient's email for attached data transfer files. Once a
file is received, it is moved to the “receiving” directory. When using FTP, the data
is ftp’d to the “receiving” directory. The Data Receiver service monitors for newly
imported files in the receiving directory and automatically uploads the data transfer
file contents into the EDM database.
Additionally, the Field Office Data Transfer allows for Status updates, so when data
is sent the sender can come back at a later time and update the status information,
which grabs the log file on the receiver and updates the sender with the current
status of the transfer.
The Field Office Data Transfer application also contains a Well Explorer, from
which you can Import or Export, create nodes, edit properties, etc., as you can in
the other EDM applications.
5000.1.7
Page 6 of 423
May 2010
Draft
EDM Report Manager
This application is used to generate, view, save, and send Output Reports created
with the EDT Drilling and Completions applications and is available to applications
such as OpenWells, PROFILE, WELLPLAN, and COMPASS. Landmark plans to
implement this Report Manager in other EDM applications in future releases.
Introduction To Engineer’s Desktop™
EDT™ Release Notes
Go To “What’s In This Release?”
EDM to OpenWorks Link
EDM-OpenWorks Link is a tool that enables you to map wells in the selected EDM
database to projects in the selected OpenWorks® database. This association
between databases is called “mapping.” EDM to OpenWorks Link supports
OpenWorks version 5000.0.1.
EDM Publishing Service
The EDM Publishing Service is a configuration utility and Windows service that
enables automated or manual generation and/or email distribution of OpenWells
Reports in printed (hard copy) or electronic (.PDF) format.
Draft
EDM Services Controller
The EDM Services Controller runs in the Windows System Tray and enables EDM
Services to be configured, started, stopped, and restarted. The following Services
are managed by the EDM Services Controller: LGC EDM Data Receiver (Email),
LGC EDM Data Receiver (File System), LGC EDM Simultaneous Activity Monitor,
and LGC EDM Publishing.
SQL Server Utility
This utility replaces the MSDE Administration Utility, and is used with SQL Server
2005 and SQL Server 2005 Express. Use the SQL Server Utility to perform the
following functions:
•
Install Microsoft SQL Server 2005 Express if it is not present on the local
machine
•
Create a blank copy of the EDM database
•
Attach an EDM database file to Microsoft SQL Server 2005 Express
•
Create two default users for new Microsoft SQL Server 2005 Express
databases:
•
— username: EDM, password: landmark (Default application user)
— username: EDM_SA, password: landmark (Administration only).
Compress existing Microsoft SQL Server 2005 Express databases
•
Detach existing Microsoft SQL Server 2005 Express databases
5000.1.7
Page 7 of 423
May 2010
Introduction To Engineer’s Desktop™
EDT™ Release Notes
Go To “What’s In This Release?”
Drilling Data Migration Utility
The migration of pre-2003.5 COMPASS and WELLPLAN legacy data to the EDM
database is a three-step process using the Data Migration Toolkit provided with the
Engineer’s Desktop 5000.1 release. Legacy DIMS data can also be migrated using
this toolkit. Tubular casing design data from StressCheck and CasingSeat
applications is not migrated using this process. After installing EDM, CasingSeat
and StressCheck software, users may import legacy data sets in either .SCK, .PDI,
or .XML format from previous versions directly into the EDM database using the
File > Import menu within the applications. To accomplish the migration of data
from pre-2003.5 databases to the EDM database, the following tools are used:
Drilling Field Mapping Tool
•
Drilling Data Migration Tool
•
EDM Data Merging Tool
Draft
•
This data migration process is critical to ensure integrity of the EDM data set
created. Further information of the Data Migration process is available in the
EDT™ Drilling Data Migration Guide document included with the EDT 5000.1.0
Release.
After the data migration, the first time that the COMPASS application is launched
it re-calculates definitive surveys for new data based on the survey program and
survey station data.
If you install WELLPLAN software, the “WELLPLAN 2000 wfw Migration” utility will
also be installed. This utility allows you to migrate .wfw transfer files from
WELLPLAN 2000 into the EDM database.
Drilling Engineering Applications
COMPASS Software
The COMputerized Planning and Analysis Survey System software is a
comprehensive tool used by oil companies and directional drilling contractors for
directional well design and construction. COMPASS software offers a fast and
accurate means of well planning and identification of potential directional drilling or
anti-collision problems at the earliest possible stage.
It includes all the features required for complex well trajectory design, survey and
anti-collision monitoring, and analysis. COMPASS software also includes tools for
survey data management, multiple planning methods, torque-drag optimization,
anti-collision plotting, and analysis, and platform optimization.
5000.1.7
Page 8 of 423
May 2010
Introduction To Engineer’s Desktop™
EDT™ Release Notes
Go To “What’s In This Release?”
Click here to view the COMPASS enhancements, fixed issues, and known issues
for 5000.1.7.
CasingSeat software is fully integrated with StressCheck software, enabling a
precise engineering workflow for more detailed design and stress load analysis of
the casing design.
Click here to view the CasingSeat enhancements, fixed issues, and known issues
for 5000.1.7.
StressCheck Software
Landmark’s StressCheck software is a graphics-based casing design product for
Microsoft Windows. It incorporates an array of attributes to enable the user to
quickly, systematically, and accurately evaluate casing wear limits, minimum cost
design, and working-stress design for burst, collapse, axial installation, and
service-life load cases.
StressCheck software is based on casing design principles that are broadly
accepted and employed in the petroleum industry. CasingSeat and StressCheck
software are referred to as ‘Tubular’ applications.
Click here to view the StressCheck enhancements, fixed issues, and known issues
for 5000.1.7.
Well Cost Software
Landmark created Well Cost software so that Drilling and Completion Engineers
could quickly perform accurate and efficient cost and planning operation analysis
throughout the life of a well. Well Cost software provides engineers with the ability
to generate cost estimates for either low-level budgeting purposes (such as during
initial project scope), or the more detailed Authorization for Expenditure (AFE).
5000.1.7
Page 9 of 423
May 2010
Draft
CasingSeat Software
Landmark’s CasingSeat software is used to design viable schemes consisting of
casing shoe setting depths and casing sizes. It provides rigorous shoe selection
calculation routines to optimize shoe locations based on pore pressure, fracture
gradients and user-defined design constraints. It features inventory-based
management of permissible hole and casing size combinations. The application
provides layer- and lithology-based characterization of subsurface boundary
conditions and operating constraints, including those associated with wellbore
stability, minimum overbalance, and differential sticking.
Introduction To Engineer’s Desktop™
EDT™ Release Notes
Go To “What’s In This Release?”
Well Cost is Landmark's replacement for DrillModel™ software, a tool that provides
deterministic Cost AFE analysis but does not offer probabilistic modeling and is not
integrated with other applications or databases. Well Cost software places a
powerful tool in the hands of engineers that is:
•
integrated with OpenWells and EDM software
•
capable of performing deterministic and probabilistic analysis
•
flexible and easy to configure
•
intuitive and easy to use with an interface that is similar to other Engineer's
Desktop applications.
WELLCAT Software
WELLCAT™ software provides precise solutions for both wellbore analysis and
integrated casing and tubing design. The software calculates accurate downhole
temperature and pressure profiles which can be used for pipe-body movement and
casing and tubing load analysis. WELLCAT software is the tool of choice for many
companies operating in high-pressure, high-temperature (HPHT) deepwater or
heavy oil drilling and production environments. The software integrates five
modules into a common environment to provide more accurate and reliable
solutions to complex design problems. Thermal effects are modeled for drilling and
production operations. A comprehensive analysis of loads and stresses on casing
and tubing is provided, including service life analysis. Detailed analysis of the entire
casing system is provided to understand the effects of annular pressure buildup
and the interaction in the casing and tubing systems within a well. Loads and their
resulting wellhead movement are evaluated to determine the integrity of the well
tubulars.
Click here to view the WELLCAT enhancements, fixed issues, and known issues
for 5000.1.7.
WELLPLAN Software
WELLPLAN software is a drilling engineering analysis system designed for use at
the rig site and the office to provide both well planning and operations analysis. The
different engineering modules of WELLPLAN software are seamlessly integrated
and address aspects of data collection, analysis, well planning, and modeling.
WELLPLAN software can be used to improve well designs, prevent stuck pipe and
BHA failures, prevent drilling problems, and essentially drill the right wells the first
time at a lower cost. General well information is entered through common editors
5000.1.7
Page 10 of 423
May 2010
Draft
Click here to view the Well Cost enhancements, fixed issues, and known issues for
5000.1.7.
Introduction To Engineer’s Desktop™
EDT™ Release Notes
Go To “What’s In This Release?”
to enable basic Case data components to be entered (e.g., wellbore editor, string
editor, fluid editor, and survey editor). These editors are generally available in most
WELLPLAN modules depending on which module or mode of analysis is being
used. Additional data required for particular analyses are entered using editors
available within each analysis module (e.g., Torque/Drag Actual Loads, Cement
Job Editor, etc.).
Click here to view the WELLPLAN enhancements, fixed issues, and known issues
for 5000.1.7.
Draft
Data Management Applications
Data Analyzer Software
Data Analyzer software provides an easy-to-use, powerful tool for EDT Drilling &
Completions users, which enables them to realize maximum value from their
captured well operations and engineering information. Data Analyzer software
provides all user levels the ability to quickly and easily build simple and complex
ad-hoc queries against drilling and well services data. Ad-hoc queries can be
generated, with the user selecting from the same user-defined labels and data
input structure that they are familiar with in the applications.
Click here to view the Data Analyzer enhancements, fixed issues, and known
issues for 5000.1.7.
OpenWells Software
OpenWells software is our latest Drilling, Completions, and Well Services—and
now Construction and Reclamation—operations reporting application. It is a fully
integrated and comprehensive, communications, analysis and corporate
engineering information data management system. It is used to capture
information for all operations across the entire well life cycle.
Wellsite operations reporting offers a new look and feel by taking advantage of the
flexibility of a new Java-based architecture and our Engineers Data Model (EDM)
software to provide integration between Drilling, Completions, Well Services, and
Production products. OpenWells software shares a common database with the
CasingSeat, StressCheck, COMPASS, WELLPLAN, WELLCAT, Data Analyzer,
PROFILE, Well Cost, and Real-Time View applications. All products also have
consistent Data Management, Navigation, Security, Data Synchronization, Unit
Management, Geodetic, and Depth Reference Datum Elevation systems.
Consistent user interface components and methods have been implemented
wherever possible between all EDM applications to provide the user with a
consistent experience across applications.
5000.1.7
Page 11 of 423
May 2010
Introduction To Engineer’s Desktop™
EDT™ Release Notes
Go To “What’s In This Release?”
You can configure the OpenWells application to meet the specific needs of a
company through customizable Data Entry Forms, Preview Panes, Output
Reports, and the Unit Management System.
The following components are available in OpenWells software:
•
— Details - Performance Indicators (Yes/No values)
— Drilling - Drilling Methods and Techniques

Once the performance data has been prepared for Submission, a DPR
Submission Wizard enables the user to generate an Excel spreadsheet to the
5000.1.7
Page 12 of 423
May 2010
Draft
OpenWells Performance Reviews: OpenWells Performance Reviews
software assists operators, performance engineers, supervisors, and system
administrators to extract, edit and manage drilling performance information for
review and submission to the Rushmore Reviews operations performance
benchmarking system. Engineers are able to quickly extract, modify and
manage Rushmore submissions sourced directly from their OpenWells
operations reports saving them time and money. 

Using Rushmore Drilling Performance Reviews (DPR), operators are able to
measure and compare their known drilling performance, for all wells in a given
region or country over a given year, against the drilling performance of their
peers in the industry. This enables operators to determine best-in-class
performance as well as improve benchmarks for future well planning
processes. OpenWells Performance Reviews provides engineers with a
valuable utility to populate their submissions direct from their well operations
reports. This first release of Performance Reviews is limited to the Drilling
Performance Reviews (DPR) submission only. A future release (2007) will
extend the offering to support Rushmore's Completions Performance Review
(CPR).

A separate application developed on the OpenWells software framework,
OpenWells Performance Reviews enables the user to create a new DPR data
set for one or more selected operations (Events). This includes the ability to
segment an Event by date where it includes multiple operations e.g., 'Drill &
Complete'. Once the operations and wellbores have been selected for the new
DPR extract, the operations performance data is extracted from the
OpenWells-entered reports and saved to a separate DPR data set. An editor
enables the engineer to review the extracted performance data, make additions
to Rushmore-specific areas and save the data. To support Rushmore reporting.
the Wellbore Properties area of OpenWells Well Explorer in Performance
Reviews (only) has also been extended to support two new data entry tabs:
Introduction To Engineer’s Desktop™
EDT™ Release Notes
Go To “What’s In This Release?”
Rushmore Reviews DPR format. Data can be submitted to 'ft' or 'm' depth units.
Once generated, the Excel spreadsheet is saved with the submission data set
as an internal attachment which can be opened up within the module.
•
Property Loader: Property Loader is a financials integration utility provided
with the OpenWells application that enables operators to initialize new Wells,
Events and AFEs using information auto-populated from 3rd party financials
systems. A 'PL' staging area within the EDM database schema is available
which operators can configure their financials systems to populate. Once
populated, the Property Loader application is used by the Well Planner to
validate the staged data and create new wells.
PROFILE Software
PROFILE software enables any engineer, from a rig supervisor to a completions
engineer to a business analyst, to quickly visualize currently installed and historical
wellbore information and downhole equipment in the form of wellbore schematics
and reports. This allows them to be updated quickly with the current well
configuration and history.
Click here to view the PROFILE enhancements, fixed issues, and known issues for
5000.1.7.
Real-Time View Software
Real-Time View software is a new time-based log viewing environment integrated
into the Engineer’s Desktop software. The Real-Time View application provides
operators with the ability to display and output configurable drilling, completions,
and workover data logs integrated with operations report information entered at the
rigsite. Using WITSML, real-time data can be imported into the EDM database via
the OpenWire® application. LAS or ASCII log data can also be imported into the
EDM database. The Real-Time View application provides a user-configurable log
viewing environment with various display options available to enable engineers to
review rig and downhole equipment operations in context with the rigsite
supervisor’s interpretation of the rig operation. Therefore, the Real-Time View
application enables operations and well-planning teams to review decisions taken
at the wellsite, perform detailed after-action reviews, and identify situations that
may lead to NPT.
Click here to view the Real-Time View enhancements, fixed issues, and known
issues for 5000.1.7.
5000.1.7
Page 13 of 423
May 2010
Draft
Click here to view the OpenWells enhancements, fixed issues, and known issues
for 5000.1.7.
System Requirements
EDT™ Release Notes
Go To “What’s In This Release?”
System Requirements
The 5000.1.7 update release supports the platform roll that was done for the 5000.1.3
release. Supported platforms and databases are listed below.
Supported Platforms and Databases for 5000.1.7
Windows XP SP3, 32-bit
•
Windows Vista SP1, 32-bit
•
Windows Vista SP1, 64-bit
•
Windows 2003 Server SP2, 32-bit
•
Windows 2008 Server SP1, 64-bit
•
Citrix Presentation Server 4.5
•
Citrix XenApp 5.0
•
Oracle 10.2.0.4 Server, 64-bit
•
Oracle 10.2.0.4 Client, 32-bit (64-bit Client not supported)
•
SQL Server 2008, 64-bit
•
SQL Server Express 2005, SP3, 32-bit
Draft
•
Hardware Requirements
The minimum and recommended system requirements for these platforms follow.
5000.1.7
Page 14 of 423
May 2010
System Requirements
EDT™ Release Notes
Go To “What’s In This Release?”
Network Clients or Standalone
Minimum for Windows XP 32-Bit Platform
•
Windows® XP Professional, SP3, 32-Bit
•
Windows® XP Professional, SP3, 32-Bit
•
2 GHz processor
•
1 GHz processor
•
2 GB RAM or greater
•
1 GB RAM
•
SVGA Color Monitor
•
SVGA Color Monitor
•
106-key Windows-ready integrated
keyboard
•
106-key Windows-ready integrated
keyboard
•
MS-compatible mouse or pointing device
•
MS-compatible mouse or pointing device
•
TCP/IP based network connection 100
Mbps,
or
FLEXid dongle (bitlock), FLEXnet Publisher
version 11.2 (for licensing)
•
TCP/IP based network connection 100
Mbps,
or
FLEXid dongle (bitlock), FLEXnet Publisher
version 11.2 (for licensing)
•
3 GB or better disk space
•
2.1GB disk space (with everything
installed)
•
CD-ROM drive (not required if installing
from a network location)
•
CD-ROM drive (not required if installing
from a network location)
•
For Standalone systems, should have
parallel port or USB port if dongle/bitlock
license used
•
For Standalone systems, should have
parallel port or USB port if dongle/bitlock
license used
•
•
•
•
Recommended for Windows Vista 32-Bit
Platform
Minimum for Windows Vista 32-Bit Platform
•
Windows® Vista Enterprise, SP1, 32-Bit
•
Windows® Vista Enterprise, SP1, 32-Bit
•
2 GHz processor
•
1 GHz processor
•
2 GB RAM or greater
•
1 GB RAM
•
SVGA Color Monitor
•
SVGA Color Monitor
•
106-key Windows-ready integrated
keyboard
•
106-key Windows-ready integrated
keyboard
•
MS-compatible mouse or pointing device
•
MS-compatible mouse or pointing device
•
TCP/IP based network connection 100
Mbps, 
or
FLEXid dongle (bitlock), FLEXnet Publisher
version 11.4 (for licensing)
•
TCP/IP based network connection 100
Mbps, 
or
FLEXid dongle (bitlock), FLEXnet Publisher
version 11.4 (for licensing)
•
5000.1.7
•
Page 15 of 423
May 2010
Draft
Recommended for Windows XP 32-Bit Platform
System Requirements
EDT™ Release Notes
Go To “What’s In This Release?”
Recommended for Windows Vista 32-Bit
Platform
Minimum for Windows Vista 32-Bit Platform
•
3 GB or better disk space
•
2.1GB disk space (with everything
installed)
•
CD-ROM drive (not required if installing
from a network location)
•
CD-ROM drive (not required if installing
from a network location)
•
For Standalone systems, should have
parallel port or USB port if dongle/bitlock
license used
•
For Standalone systems, should have
parallel port or USB port if dongle/bitlock
license used
Minimum for Windows Vista 64-Bit Platform
•
Windows® Vista Enterprise, SP1, 64-Bit
•
Windows® Vista Enterprise, SP1, 64-Bit
•
2 GHz processor
•
1 GHz processor
•
2 GB RAM or greater
•
1 GB RAM
•
SVGA Color Monitor
•
SVGA Color Monitor
•
106-key Windows-ready integrated
keyboard
•
106-key Windows-ready integrated
keyboard
•
MS-compatible mouse or pointing device
•
MS-compatible mouse or pointing device
•
TCP/IP based network connection 100
Mbps, 
or
FLEXid dongle (bitlock), FLEXnet Publisher
version 11.4 (for licensing)
•
TCP/IP based network connection 100
Mbps, 
or
FLEXid dongle (bitlock), FLEXnet Publisher
version 11.4 (for licensing)
•
3 GB or better disk space
•
2.1GB disk space (with everything
installed)
•
CD-ROM drive (not required if installing
from a network location)
•
CD-ROM drive (not required if installing
from a network location)
•
For Standalone systems, should have
parallel port or USB port if dongle/bitlock
license used
•
For Standalone systems, should have
parallel port or USB port if dongle/bitlock
license used
•
•
A video card with 3-D rendering capability is required, with a minimum of 128MB video
RAM. This should be an actual video card (not a motherboard clip). Note that the graphics
card must reside on the server if you are using PROFILE software.
5000.1.7
Page 16 of 423
May 2010
Draft
Recommended for Windows Vista 64-Bit
Platform
System Requirements
EDT™ Release Notes
Go To “What’s In This Release?”
Servers
Minimum for Windows 2003 Server Standard
Edition, 32-Bit Platform
•
Windows® 2003 Server, SP2, 32-Bit
•
Windows® 2003 Server, SP2, 32-Bit
•
2 GHz or higher
•
1.5 GHz processor
•
4 GB RAM (4 is the maximum allowed for
Standard Edition)
•
2 GB RAM
•
VGA Color Monitor
•
VGA Color Monitor
•
106-key Windows-ready integrated
keyboard
•
106-key Windows-ready integrated
keyboard
•
MS-compatible mouse or pointing device
•
MS-compatible mouse or pointing device
•
TCP/IP based network connection 100
Mbps
•
TCP/IP based network connection 10 Mbps
•
2-4 GB or better disk space
•
2 GB disk space
•
CD-ROM drive (not required if installing
from a network location)
•
CD-ROM drive (not required if installing
from a network location)
Recommended for Windows 2003 Server
Enterprise Edition, 32-Bit Platform
Minimum for Windows 2003 Server Enterprise
Edition, 32-Bit Platform
•
Windows® 2003 Server, SP2, 32-Bit
•
Windows® 2003 Server, SP2, 32-Bit
•
2 GHz or higher
•
1.5 GHz processor
•
8 GB RAM or greater (32 is the maximum
allowed for Enterprise Edition)
•
4 GB RAM
•
VGA Color Monitor
•
VGA Color Monitor
•
106-key Windows-ready integrated
keyboard
•
106-key Windows-ready integrated
keyboard
•
MS-compatible mouse or pointing device
•
MS-compatible mouse or pointing device
•
TCP/IP based network connection 100
Mbps
•
TCP/IP based network connection 10 Mbps
•
2-4 GB or better disk space
•
2 GB disk space
•
CD-ROM drive (not required if installing
from a network location)
•
CD-ROM drive (not required if installing
from a network location)
5000.1.7
Page 17 of 423
May 2010
Draft
Recommended for Windows 2003 Server
Standard Edition, 32-Bit Platform
System Requirements
EDT™ Release Notes
Go To “What’s In This Release?”
Minimum for Windows 2008 Server, 64-Bit
Platform
•
Windows® 2008 Server, SP1, 64-Bit
•
Windows® 2008 Server, SP1, 64-Bit
•
2 GHz or higher
•
1.5 GHz processor
•
8 GB RAM or greater
•
4 GB RAM
•
VGA Color Monitor
•
VGA Color Monitor
•
106-key Windows-ready integrated
keyboard
•
106-key Windows-ready integrated
keyboard
•
MS-compatible mouse or pointing device
•
MS-compatible mouse or pointing device
•
TCP/IP based network connection 100
Mbps
•
TCP/IP based network connection 10 Mbps
•
2-4 GB or better disk space
•
2 GB disk space
•
CD-ROM drive (not required if installing
from a network location)
•
CD-ROM drive (not required if installing
from a network location)
A video card with 3-D rendering capability is required, with a minimum of 128MB video
RAM. This should be an actual video card (not a motherboard clip). Note that the graphics
card must reside on the server if you are using PROFILE software.
Note: Windows Vista servers are not supported. Only standalone Vista is supported.
Citrix
The 5000.1.7 Engineer’s Desktop applications have been tested in 2 separate Citrix thinclient environments. The test environments consisted of three server-class PCs:
Environment 1 (Primary Test Environment):
Server 1 (Database server, SAM server)
Operating System:
•
Windows 2008 Server Enterprise Edition, SP1, 64-Bit
Services:
•
•
•
Oracle 10g (10.2.0.4), 64-Bit
EDM database
(SAM) Simultaneous Access Monitor (Note that the SAM server
should not be on the same server with Citrix and the published
applications)
5000.1.7
Page 18 of 423
May 2010
Draft
Recommended for Windows 2008 Server, 64-Bit
Platform
System Requirements
EDT™ Release Notes
Go To “What’s In This Release?”
Server 2 (Citrix and Applications)
Operating System:
•
Windows 2008 Server Enterprise Edition, SP1, 64-Bit
Services:
•
•
•
Citrix XenApp 5.0
Citrix Resource Manager
Citrix License Server components
Server 3 (Citrix and Applications)
•
Windows 2003 Server Enterprise Edition, SP2
Services:
•
•
•
Citrix XenApp 5.0
Citrix Resource Manager
Citrix License Server components
Draft
Operating System:
Citrix Client
Version:
11.00 (do not use the 9.23 Client version used for the 5000.1.0 release;
if you use 9.23, there will be issues with XenApp)
Environment 2 (Secondary Test Environment):
Server 1 (Database server, SAM server)
Operating System:
•
Windows 2003 Server Enterprise Edition, SP2, 32-Bit
Services:
•
•
•
SQL Server 2008, 64-Bit
EDM database
(SAM) Simultaneous Access Monitor (Note that the SAM server
should not be on the same server with Citrix and the published
applications)
Server 2 (Citrix and Applications)
Operating System:
•
Windows 2003 Server Enterprise Edition, SP2, 32-Bit
Services:
•
•
•
Citrix Presentation Server 4.5
Citrix Resource Manager
Citrix License Server components
Server 3 (Citrix and Applications)
Operating System:
•
Windows 2003 Server Enterprise Edition, SP2, 32-Bit
Services:
•
•
•
Citrix Presentation Server 4.5
Citrix Resource Manager
Citrix License Server components
Citrix Client
Version:
5000.1.7
11.00
Page 19 of 423
May 2010
System Requirements
EDT™ Release Notes
Go To “What’s In This Release?”
Citrix Servers (Tested Machine Configuration 1)
• Windows® 2008 Server Enterprise Edition, SP1, 64-Bit
• 2 x 933 MHz Intel Pentium III processors
• 8 GB RAM
• TCP/IP-based network connection 100 Mbps (both NICs)
• 18 GB disk space
Draft
Citrix Servers (Tested Machine Configuration 2)
• Windows® 2003 Server Enterprise Edition, SP2, 32-Bit
• 2 x 933 MHz Intel Pentium III processors
• 4 GB RAM
• TCP/IP-based network connection 100 Mbps (both NICs)
• 18 GB disk space
Note: Citrix can be configured in a number of different ways. We have only tested the
configurations outlined above.
When no C drive is present on the system, Microsoft® Windows® Installer (MSI) requires
you to run the install from a command line, with a switch. The syntax is:
setup.exe /v"DIRPROPERTY5=[DRIVE]:\\"
where [DRIVE] denotes the destination drive letter. For example, if your drive is M:
setup.exe /v”DIRPROPERTY5=M:\\"
For more details on Citrix issues, refer to the EDT™ Software on Citrix Guide
(EDT_Citrix.pdf).
5000.1.7
Page 20 of 423
May 2010
System Requirements
EDT™ Release Notes
Go To “What’s In This Release?”
ODBC Drivers and Database Server Versions
The following table lists ODBC Drivers and Database Server versions and their
corresponding version numbers used during our testing of the Engineer’s
Desktop 5000.1.7 release. This table describes which ODBC drivers our test labs have
certified and which drivers we support for use with EDT applications.
Operating System
ODBC Driver
Version
SQL Native Client
2005.90.4035.00
Windows Vista SP1, 32-bit
SQL Native Client
2005.90.4035.00
Windows Vista SP1, 64-bit
SQL Native Client
2005.90.4035.00
Windows 2003 Server SP2, 32-bit
SQL Native Client
2005.90.4035.00
Windows 2003 Server SP2, 64-bit
N/A (not a tested platform)
Windows 2008 Server SP1, 64-bit
SQL Native Client
2005.90.4035.00
Oracle 10g Client, 32-bit ODBC Driver
Oracle Client
10.02.00.04
Server
Version
Oracle 10g Server, 64-bit
10.2.0.4
SQL Server 2008, 64-bit
10.0.1600.22
SQL Server Express 2005, SP3, 32-bit (or systems
with SQL Server Express installed)
9.00.3042
SQL Server Express 2005, SP3, 64-bit (or systems
without SQL Server Express installed
9.00.4035
No longer supported: Oracle 9i, Microsoft MSDE, Microsoft SQL Server 2000, Windows
2000.
5000.1.7
Page 21 of 423
May 2010
Draft
Windows XP SP3, 32-bit
System Requirements
EDT™ Release Notes
Go To “What’s In This Release?”
Configuration Combinations For Engineer’s Desktop™, DecisionSpace®, 
and OpenWorks® Applications
Engineer’s Desktop
5000.1.7, on
Oracle 10g
Engineer’s Desktop
5000.1.7
on SQL Server 2008
or SQL Server 2005
Express
DecisionSpace®
5000.0.3.0 and
OpenWorks®
5000.0.2.2 on
Oracle 10g
Windows Vista
Enterprise, 32-bit
yes*
yes*
yes
Windows Vista
Enterprise, 64-bit
yes*
yes*
yes
Windows XP
Professional, 32-bit
yes
yes
yes
Windows 2003
Server, 32-bit
yes
not tested
not tested
Windows 2003
Server, 64-bit
yes
yes
yes
Windows 2008
Server, 64-bit
yes*
yes*
yes
Draft
Operating System
Applications
* COMPASS Live Link does not work on Windows Vista 32- or 64-bit
Supported for EDT 5000.1.6 on all tested platforms are:
•
EDM™ AutoSync Client/Server (latest version is 5000.1.6) is supported for EDT
5000.1.6 (however, does not support the new Well Cost tables added in EDT
5000.1.6)
Not supported for EDT 5000.1.6 are:
•
DecisionSpace® 3D Drill View KM™ (latest version is 5000.0.3.0) is supported for
EDT 5000.1.5, but not for EDT 5000.1.6
•
DecisionSpace® Wellplanning (latest version is 5000.0.4.0) is supported for EDT
5000.1.5, but not for EDT 5000.1.6
•
iWellFile™ (latest version is 5000.1.5) not supported for EDT 5000.1.6
•
EDM™ SDK (latest version is 5000.1.5) not supported for EDT 5000.1.6
•
OpenWire® Client (latest version is 5000.1.3) not supported for EDT 5000.1.6
5000.1.7
Page 22 of 423
May 2010
System Requirements
EDT™ Release Notes
Go To “What’s In This Release?”
•
OpenWire® Server (latest version is 5000.1.3) not supported for EDT 5000.1.6
•
OpenWire® Data Flow Manager (latest version is 5000.1.0) not supported for EDT
5000.1.6
Third-Party Applications
A number of third-party applications must be installed for Engineer’s Desktop applications
to function properly. These were installed as part of the EDT version 5000.1.0 full
installation.
•
•
•
•
•
5000.1.7
Microsoft Data Access Components 2.8 (MDAC)
Crystal Reports 11.5, SP3
Microsoft .NET Framework 2.0
Landmark LAM 5000
Microsoft Visual J# .NET Redistributable Package 2.0
Page 23 of 423
May 2010
Draft
The third-party applications that were installed in the 5000.1.0 installation are listed below.
(Refer to the EDT™ Version 5000.1.0 Summary Level Release Notes for complete
details.)
Third-Party Software
EDT™ Release Notes
Go To “What’s In This Release?”
Third-Party Software
Landmark uses various third-party applications in the development of its software.
Landmark acknowledges that certain third party code has been bundled with, or
embedded in, Landmark’s software. The licensors of this third party code, and the terms
and conditions of their respective licenses, may be found at the following location:
[Installdir]\Documentation\Third_Party.pdf
Products that are Embedded in or Installed by Release 5000.1.7
Installed Product/Package
Version for all
supported
Operating Systems
Apache/XML Xerces
1.4.x
Blue Marble Geographic Calculator
6.2
Commons BeanUtils
1.4.1
Commons Collections
2.0
Commons Logging
1.0.2
ComponentOne LLC Chart™
7.0
Crystal Project, © 2008 The Yellow Icon. All rights reserved.
N/A
Crystal Reports™ (note that one Crystal Reports™ Developer license per site
is required if you want to customize reports)
XI SP3
DEX
2003.14.3.70
Geobase® (Digital Elevation Data, and Satellite Imagery)
N/A
Hewlett-Packard Development Company, L.P., Compaq Visual Fortran
6.1a
iText
2.1.6
Macrovision™ Corporation FLEXnet Publisher™
11.6
Macrovision™ InstallShield Admin Studio™
6.0
Microsoft® Data Access Components (MDAC)
2.8 SP1
Microsoft® J# FrameWork
1.1
Microsoft® SQL Server 2005 Express Edition (replaces MSDE)
SP2
Microsoft® .NET Framework 2.0
2.0
5000.1.7
Page 24 of 423
May 2010
Draft
The following table describes the third party applications that are installed by Release
5000.1.7.
Third-Party Software
EDT™ Release Notes
Go To “What’s In This Release?”
Products that are Embedded in or Installed by Release 5000.1.7
Version for all
supported
Operating Systems
Microsoft® Visual C++ 2005 Service Pack 1 Redistributable Package ATL
Security Update (filename: vcredist_x86.exe)
2005 SP1 (v. 8.0)
Rogue Wave
6.0.4
Rogue Wave™ Software, Inc., Stingray Studio – Objective Grid PRO
8
Rogue Wave™ Software, Inc., Stingray Studio – Objective Grid Standard
8
Rogue Wave™ Software, Inc., Stingray Studio – Objective Toolkit Standard
8
SCGrid.com, SCGrid Active X grid Control
4.5.0.3
Silicon Graphics®, Inc. OpenGL®
1.2
Sun Microsystems, Inc., JOGL (Java Bindings for OpenGL). Copyright © 20032007 Sun Microsystems, Inc. All rights reserved.
1.1.1a
TCL Library (Tclib)
8.2.3
Draft
Installed Product/Package
The following table describes prerequisite applications (these are not included in the
release 5000.1.7 install). Some are required for all features (for example, operating
system, Adobe Acrobat, Microsoft® Internet Explorer) and some are required only for
certain applications or to enable specific features.
Prerequisite Products (not installed by Release 5000.1.7)
Prerequisite Product/Package
Version
Certified operating system
•
•
•
•
•
•
Adobe® Systems Inc., Adobe®
Reader®
7.0.9 or later
Hummingbird® Ltd., Exceed®/
Exceed 3D
2007 

If OpenWorks Basic is installed (instead of the Full install), then
not required
Microsoft® Internet Explorer
7.0
Microsoft® SQL Server 2005
SP2
5000.1.7
Windows® Vista Enterprise, SP1, 32-bit
Windows® Vista Enterprise, SP1, 64-bit
Windows® XP Professional, SP3
Windows® 2003 Server Standard, SP2, 32-bit
Windows® 2003 Server Enterprise, SP2, 32-bit
Windows® 2008 Server Enterprise, SP1, 64-bit
Page 25 of 423
May 2010
Third-Party Software
EDT™ Release Notes
Go To “What’s In This Release?”
Prerequisite Products (not installed by Release 5000.1.7)
Version
MKS Inc., MKS Toolkit® for
Enterprise Developers (formerly
known as NuTCRACKER)
9.2.0100

If OpenWorks Basic is installed (instead of the Full install), then
not required
Oracle Corporation, ORACLE®
Client
10g, 32-bit
Oracle Corporation, ORACLE®
Server
10g, 64-bit
Sun Microsystems™ Inc., Java ™ 2
Runtime Environment, Standard
Edition
1.6.1
5000.1.7
Page 26 of 423
Draft
Prerequisite Product/Package
May 2010
Other Requirements
EDT™ Release Notes
Go To “What’s In This Release?”
Other Requirements
Space Requirements for Individual Applications and Tools
The table below shows the minimum disk space requirements for various installation
combinations (this includes space needed for Installation temporary files):
Approximate Disk Space Needed to Install
Engineer’s Data Model (EDM)
• Administration Utility (required)
• SQL Server Utility (required)
• Drilling Data Migration
• Database Upgrade Utilities
780 MB

(Required support files will be copied into the
Windows installation directory; the installation of
EDM software and SQL Server 2005 support and
temporary installation files requires 400 MB of disk
space)
Drilling & Completions: Engineering
• COMPASS
• CasingSeat
• StressCheck
• Well Cost
• WELLCAT
• WELLPLAN
335 MB
Drilling & Completions: Well Data Management
• OpenWells
• PROFILE
• Data Analyzer
• Real-Time View
250 MB
TOTAL: Everything
~2.0 GB

Screen Resolutions/Video
Recommended
Minimum
•
•
1024 x 768 or higher
1024 x 768
A video card with 3-D rendering capability is required, with a minimum of 128MB video
RAM. This should be an actual video card (not a motherboard clip). Note that the graphics
card must reside on the server if you are using PROFILE software.
If you experience display problems when running PROFILE, PROFILE Symbol Manager,
or graphs in WELLPLAN Critical Speed module, upgrade your video driver to the latest
version.
5000.1.7
Page 27 of 423
May 2010
Draft
Applications
Other Requirements
EDT™ Release Notes
Go To “What’s In This Release?”
Miscellaneous
Applications require you to install a current Landmark LAM or a FLEXnet Publisher
dongle (bitlock) for licensing purposes. Landmark does not distribute FLEX dongle
bitlocks for use on application servers.
•
Windows XP and Vista users must install all Critical and Recommended Windows
Updates.
•
You need Internet Explorer 7.0 for a successful installation.
•
You need Acrobat Reader to view the release notes and other documentation in .PDF
format. If you already have version 7.0.9 or later of the Reader installed, you do not
need to re-install it. You can download the latest Reader from Adobe’s website: http:/
/www.adobe.com/products/acrobat/readstep2.html.
Upgrading the EDM Database
This installation is an upgrade from the 5000.1.0 Engineer’s Data Model version. If you
are currently using a pre-2003.14 version of the EDM database, you must upgrade your
EDM database to at least 2003.14 prior to running the Multi-Version Database Upgrade
Utility (EDMPatchDB.exe) to upgrade to the 5000.1.0 release. Once you are on version
5000.1.0 (or higher), you can install EDT 5000.1.7.
Note that once the EDM database has been upgraded to 5000.1.7, you will no longer be
able to access it using the earlier applications.
Installing With Previous Versions
EDT 5000.1.7 software is an update—it will update your EDT 5000.1.0 or higher software.
5000.1.7 can co-exist with previous versions of EDT software on the same machine.
However, LAM 5000 will not co-exist with earlier versions of LAM (FLEXlm license server)
on the same machine.
To run EDT 5000.1.7 applications and a previous version of the EDT applications on the
same machine, you must point one or both versions of EDT software to a LAM server
located on a remote machine, since only one version of LAM can run locally. Refer to the
EDT™ Version 5000.1.0 Summary Level Release Notes for details.
Microsoft Security Warnings When Installing
A security warning may appear when trying to install software, due to security restrictions
imposed by recent Microsoft security updates:
5000.1.7
Page 28 of 423
May 2010
Draft
•
Other Requirements
EDT™ Release Notes
Go To “What’s In This Release?”
“Security Warning: Do you want to run this software?”
Simply click Run to proceed with the EDM software installation.
Data Execution Prevention
Data Execution Prevention helps protect against damage from viruses and other threats.
However, some programs may not run correctly when this is turned on. If there is a
conflict, you will see an error similar to this:
Draft
It is recommended that Data Execution Prevention be set to “Turn on DEP for essential
Windows programs and services only”
To set DEP:
1. Right-click My Computer.
2. Select Properties > Advanced tab.
3. Under Performance, click the Settings button. Select Data Execution Prevention
tab.
4. Select Turn on DEP for essential Windows programs and services only.
5. Click OK.
5000.1.7
Page 29 of 423
May 2010
Other Requirements
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
5000.1.7
Page 30 of 423
May 2010
Before You Install
EDT™ Release Notes
Go To “What’s In This Release?”
Before You Install
EDT 5000.1.0 or higher must be installed before installing this release.
The 5000.1.7 release is an update release. You must have 5000.1.0 or higher installed on your machine
to install 5000.1.7.
Before installing Engineer’s Desktop 5000.1.7, review these release notes entirely. The
release notes provide you with necessary information about:
the applications in Engineer’s Desktop 5000.1.7 software
•
the hardware and operating systems on which you can run Engineer’s Desktop
5000.1.7 software
•
product dependencies
Installation on Microsoft Vista
Running EDT applications as a non-Admin user on Microsoft Vista, 32-and-64-bit, SP1
was not supported on EDT versions prior to 5000.1.3.
The 5000.1.5 update release can be installed by a non-Admin user account.
EDT 5000.1.0
When installing EDT 5000.1.0 on Vista, you must run the executables with the “Run as
administrator” option. To run as Administrator, right-click on the “Setup.exe” for EDM,
Drilling, and Third-Party Tools. You must enter the password for the installation
machine’s Administrator account.
5000.1.7
Page 31 of 423
May 2010
Draft
•
Before You Install
EDT™ Release Notes
Go To “What’s In This Release?”
Right-click on the “Setup.exe” file, and
then select Run as administrator.
When prompted, enter the Administrator
account for the installation machine.
Draft
Note: During the 3rd Party Tools installation on EDT 5000.1.0, the following screen may
appear:
Click on “This program
installed correctly”
Click on the “This program installed correctly” option and continue with the installation.
5000.1.7
Page 32 of 423
May 2010
Before You Install
EDT™ Release Notes
Go To “What’s In This Release?”
Installation Checklist
The following checklist outlines the phases of the installation process.
1. Upgrade the Operating System, if necessary. For Windows XP, SP3 must be
installed; for Windows Vista, SP1; for Windows 2003 Server, SP2; for Windows 2008
Server, SP1.
2. Install Oracle client. For Oracle 10g, you need the 10.2.0.432 version, 32-bit (64-bit
client is not supported).
4. Before installing products you must have Adobe Acrobat Reader (you can download
the latest Reader from Adobe’s website: http://www.adobe.com/products/acrobat/
readstep2.html.) to read the available documentation.
5. Run the ZIP file to install the updated files.
6. Your 5000.1.0 product licenses are still valid for the 5000.1.7 release.
7. If you don’t have an existing EDM database and want to create one on Oracle, see
the EDM™ Drilling Database Guide (EDM_Drilling_Database.pdf) for details.
8. You need to upgrade existing 5000.1.0 or higher databases to 5000.1.7. The MultiVersion Database Upgrade Utility will upgrade your database automatically. The
utility will upgrade your database from 5000.1.0 (database version 09.00.00.115) or
higher to 5000.1.7.
IMPORTANT: If you have ever
upgraded from a 2003.11 Oracle database...
then you cannot run the upgrade utility to upgrade to 5000.1 (due to a
significant 2003.14 tablespace definitions change). In this case, call
Landmark Support.
9. Before attempting to run the PROFILE application, if you need to export PROFILE
WallPlot Composer schematics to JPG file format, Windows color depth should be
adjusted to a resolution higher than 256-bit.
10. If you have an Oracle Database: Before attempting to run the StressCheck or
CasingSeat applications, you need to upload StressCheck and CasingSeat templates
to the database manually.
5000.1.7
Page 33 of 423
May 2010
Draft
3. Set Data Execution Prevention status to “Turn on essential Windows programs and
services only.” Here is the procedure.
Before You Install
EDT™ Release Notes
Go To “What’s In This Release?”
Official 5000.1.7 Database Version
The official 5000.1.5 release database version is 09.03.04.185.
Contents of the EDT 5000.1.7 Release Software Download
Engineer’s Desktop 5000.1.7 software download contains:
A .ZIP file comprising the 5000.1.7 update. The update will add new files and update
existing EDT 5000.1.0 and higher files. Applications to be installed are described here.
•
EDT™ Software Version 5000.1.7 Release Notes. This document, which also
includes enhancements, fixed issues, and known issues for all EDT applications.
5000.1.7
Page 34 of 423
May 2010
Draft
•
Installation: 32-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
Installation: 32-Bit Operating Systems
The Engineer’s Desktop software is delivered via Electronic Delivery System using the
Landmark Software Manager tool. This is an update release, so you can install the EDT
version 5000.1.7 only if EDT 5000.1.0 or higher is already installed on your machine.
Installation Instructions (32-Bit Only)
This install consists of a self-extracting WinZip® file which includes all the updated files to
apply the required files to your system.
1. Make sure that you have EDT 5000.1.0 or higher already installed. It is prudent to
make a back up of your database files at this time.
2. Make sure that no EDT applications are running when you run this install including
Windows Services e.g., SAM, EPS.
3. Run R5000_EDT_5000.1.7.0.exe.
4. Wait for the "5000.1.7.0 Install" window to appear. Click the OK button to begin (or
Cancel to cancel the installation).
5. A second "WinZip Self-Extractor" window will open. Select Setup to proceed (Cancel
to stop the installation). 

This application will extract the updated and additional files required to a temporary
directory. and install the files being updated. A DOS Window will appear prompting
you to continue (start) the install process. Press any key to start the install. The DOS
window will then show patch install process for each file updated in this patch.
6. The next screens involve an End-User License Agreement (EULA) between
Landmark and you, the licensee. Follow the prompts to read the agreement. At the
end of the agreement, you are asked whether you accept or decline the terms within
the EULA.
5000.1.7
Page 35 of 423
May 2010
Draft
These instructions are for 32-bit systems only. If you have a 64-bit system, either Vista,
XP, or Windows 2008 Server, skip this entire section and go here for installation
instructions.
Installation: 32-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
Specify A to accept the agreement, and then press Enter.
IMPORTANT: Specific keyboard input is required to complete the installation
Only “A”, “a”, “ACCEPT”, “Accept”, or “accept” (without the quotation
marks) is allowable input to continue the installation.
To decline the agreement, press D and then press Enter. This will cancel the
installation and abort the EDT update.
7. The pertinent updated files will be installed. This will take a few minutes.
9. Your system will be checked to see if you have MSXML 4.0 SP2 Parser and SDK. If
not found, you will be prompted to set it up by clicking Next in the Wizard and
accepting the EULA (if you do not accept the EULA, the install will abort). Follow the
Wizard prompts to install this package now. Click Finish when complete.
10. Your system will be checked to see if you have Crystal Reports XI SP3 installed. If not
found, it will be installed.
11. After a few minutes, your system will be checked to see if you have SQL Server 2005
Express installed.
• If it is found, you will skip to Step 13.
• If it is not found, you are prompted to install the SQL Server Express 2005/
Management Studio components. Select Yes to install these components. Note: if
you only use Oracle for your database, you may select not to install SQL Server
2005 Express. If you select No, the EDT installation will continue without installing
SQL Server Express 2005 and Management Studio components.
12. Your system will be checked to see if you have SQL Server Management Studio
installed.
• If not found: You are prompted to install the SQL Server 2005 Express/
Management Studio components.
When the ‘SQL Server Management Studio Express’ wizard opens, click Next.
When the EULA appears, accept it and click Next; when the Registration
Information screen appears, fill in your information and click Next; when the Feature
5000.1.7
Page 36 of 423
May 2010
Draft
8. Your system will be checked to see if you have Microsoft Visual C++ 2005 SP1 and
2005 Runtime Libraries installed. If not found, you will be prompted to read and
accept an End User License Agreement for these packages. Click Yes to proceed
and install them (if you do not accept, the install will abort.)
Installation: 32-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
Selection screen appears, click Next; when the Install screen appears, click Install.
When the installation is complete, click Finish.
Rarely, a registry error might appear, which you should ignore:
Draft
Ignore this error
During the SQL Server Express 2005 install, you may see this error message:
SQL Server Express 2005 will install correctly if you
click the Run Program button
5000.1.7
Page 37 of 423
May 2010
Installation: 32-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
13. You are prompted “Would you like to create desktop shortcuts (Y/N)?” Specify Y to
create shortcuts; specify N if you don’t want shortcuts placed on the desktop.
14. Next you are prompted “Would you like to install EDM Historian now (Y/N)?”, which is
required by the OpenWells and PROFILE Data Approval feature. Specify Y to install
EDM Historian; specify N if you do not want to install EDM Historian.
Just for your information, you are informed that you may need to update your database
to support the 5000.1.7 release. (The location of the appropriate .exe scripts used to
upgrade the SQL and/or Oracle databases, respectively, are displayed.)
16. You are prompted to run the update for SQL Server and/or Oracle databases; specify
Y (yes) or N (no) options appropriately each time you are prompted. In either case, a
WinZip Self-Extractor window opens. Click Unzip to unzip files; click OK when
finished unzipping. In both cases, a WinZip Self-Extractor window opens. Click Unzip
to unzip files; click OK when finished unzipping.
If you did not elect to run SSUTILS earlier in the install

Once the EDT 5000.1.7 patch has finished running, if you want to have a
SQL Server Express 2005 database installed locally, you need to go to
Start Menu > Programs > Landmark Engineer's Desktop 5000.1 >
Tools and select the SQL Server Utility. All you do is enter is the
Database Name, i.e. 'edm' or any other name, and then press OK,
accepting the default values for all the other selections.
5000.1.7
Page 38 of 423
May 2010
Draft
15. You are prompted “Would you like to run SQL Server Utilities (SSUTILS) now (Y/N)?”
This allows you to create a SQL Server Express database instance. If you just need
to update your database, specify N and proceed to the next prompt. (Note that
specifying Y and electing to replace a database will overwrite an existing attached
database.) Specify Y if you have another SQL Server/SQL Server Express database
that you want to attach, or if this is a new database.
Installation: 32-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
Click Unzip to unzip the
files
Draft
17. The Database Update Program window opens (it may open behind the open
Cmd.exe window).
18. Oracle Only—If you are updating an Oracle database, you must run the
HIST_TBS.SQL script prior to upgrading the database. The script is extracted to the
EDT installation directory in the EDM\Updates\Oracle\EDM_5000_1_7_Update
folder.
Important if you are running
an Oracle update
Click
19. For either SQL Server or Oracle, click Run Automated to update your 5000.1.0 or
higher database to 5000.1.7.
5000.1.7
Page 39 of 423
May 2010
Installation: 32-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
20. You will be prompted to login as System Administrator to update the database.
Draft
Enter the System Administrator User Name and Password. For SQL Server the User
name is sa and the default password is Landmark1; for Oracle the default user name
shipped by Landmark was edmadmin and the password was Landmark1 (check with
your system administrator to see if the user name and password have been changed).
Select the DSN (Data Source Name) from the dropdown list (e.g., EDM 5000.1 Single
User Db for SQL Server) and click OK.
21. You will be prompted as follows (version numbers will differ depending on what
version you currently have):
5000.1.7
Page 40 of 423
May 2010
Installation: 32-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
22. Click Yes to continue. The following screen opens, showing the update in progress:
Draft
When the update concludes, click OK. The DOS window reports that the 5000.1.7
code changes were successfully installed.
23. You are prompted to press any key to exit out of the DOS session. Please review the
information in the DOS window to ensure no errors were reported. After pressing any
key, the temporary patch install directory will be deleted.
24. This concludes the patch/update installation. Next, perform the required postinstallation tasks, outlined on page 42.
Troubleshooting the Installation
If you run into problems, please refer to the “Installation Troubleshooting” section of the
EDM™ Software Installation Guide or the EDT™ Drilling Software Installation Guide.
Microsoft SQL Server Express 2005 Install Behavior With SQL Server
2008 Client/Server 2008
Microsoft SQL Server Express 2005 (Microsoft’s replacement for MSDE)
is the standalone database provided with the Engineer’s Desktop 5000.1.7
release. Microsoft SQL Server Express 2005 is a technology that provides
local data storage that is compatible with Microsoft SQL Server 2008. It is
designed and optimized for use on smaller computer systems, including a
single-user computer or small workgroup server.
Microsoft SQL Server Express 2005 installation issues impacting PCs with
SQL Server installed are listed in “Microsoft SQL Server Express 2005
Installation Issues” in the EDM Installation Guide.
5000.1.7
Page 41 of 423
May 2010
Installation: 32-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
Post-Installation Required Tasks
1. Before attempting to run the PROFILE application, if you need to export PROFILE
Wall Plot Composer schematics to JPG file format, Windows color depth should be
adjusted to a resolution higher than 256-bit.
2. Remember to reboot your computer before attempting to use the Engineer’s Desktop.
Site Configuration File Import Required Post-Install
If you are upgrading from a previous version of the database, both Oracle and Microsoft
SQL Server 2005 Express (replacement for MSDE) users will have the latest configuration
files imported automatically; you do not have to do anything. Skip to Workspaces and
Templates Import Required Post-Install on page 44.
If you have a new Oracle installation, you must import site configuration files after building
a new database. Site configuration files are imported using the EDM Administration Utility.
For an Oracle database creation, these configuration files must be imported using the EDM
Administration Utility. The files are located in the following folder once the installation is
complete: <install directory>\EDM\Site Configuration Files. The procedure to import
these files follows.
1. Launch the EDM Administration Utility.
2. Create a database connection for the upgraded database (i.e., use the File > New >
Data Source command).
3. Login to the installed database as edm/Landmark1 (user name/ password).
4. Select the Database icon in the hierarchy for the opened EDM Data Source.
5. Follow the menu path, Tools > Import and Export.
6. Select Import configuration data from local directory.
7. Click Next.
5000.1.7
Page 42 of 423
May 2010
Draft
Landmark configurations (site configuration files) are contained within the EDM database
and installed with the Microsoft SQL Server 2005 Express database. These files contain
default and customized configurations for EDM Output Reports, OpenWells Preview
Panes, OpenWells Data Entry Forms, OpenWells Shortcut Bars, and Administration
Utility input screens.
Installation: 32-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
8. Use the Browse button to navigate to the top level directory (i.e., <install
directory>\EDM\Site Configuration Files) and click OK.
9. Leave the path to the XML file descriptor blank. This will cause the default
files_descriptor.xml file to be used. The XML file descriptor (files_descriptor.xml)
populates specific columns in the table that would normally not be populated.
10. Activate the checkbox to overwrite existing files in the EDM database.
12. Close and then re-open the EDM Administration Utility to view the newly imported
files, which are now visible.
5000.1.7
Page 43 of 423
May 2010
Draft
11. Click Finish. Once the import is complete, the ImportResults.log file appears. This file
summarizes the results of the import. The beginning of the file states how many Site
Configuration files are to be imported (e.g., 659 files). The end of the file states how
many files were imported. These two numbers should be the same. If there is a
discrepancy between these numbers, contact Landmark Support. The
ImportResults.log file is located in the <EDM install directory>\Common Files folder.
Installation: 32-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
Workspaces and Templates Import Required Post-Install
Following the installation of EDT 5000.1.7, system workspaces and templates for
applications such as WELLPLAN, StressCheck, CasingSeat, and WELLCAT are
automatically uploaded to SQL Server databases, but will need to be imported to Oracle
databases.
1. In the EDM Administration Utility, select the Oracle database in the tree, then select
Tools > Import and Export. The Import and Export Wizard will open.
2. Use the “Import System Workspaces” option in the Wizard to import workspaces
and templates.
Draft
This concludes the installation of EDT software on 32-bit systems.
5000.1.7
Page 44 of 423
May 2010
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
Installation: 64-Bit Operating Systems
Skip this entire section if you have a 32-bit operating system.
Installation Instructions (64-bit Only)
These instructions are for 64-bit systems only. If you have a 32-bit system, either Vista,
XP, or Windows 2008 Server, skip this entire section and go here for installation
instructions.
Step 1. Install EDT 5000.1.0
If you already have EDT 5000.1.0 installed on your 64-bit machine, skip this Step and go
to Step 2.
Because Engineer’s Desktop did not previously support 64-bit operating systems, you will
have to first install the EDT 5000.1.0 release before you can apply the 5000.1.7 update.
Order of installation is:
•
Third-Party Components
•
EDM
•
Drilling and Completions applications
Refer to the 5000.1.0 EDT Drilling Installation Guide for detailed procedures.
Because the 5000.1.0 release was not developed for 64-bit, you will encounter a number
of error messages. These errors are shown below, using a 64-bit Vista SP1 system
example.
n Third-Party Install: Logged in as Non Admin, Not Administrator
•
Right click on Third Party Setup.exe and Run as Administrator:
5000.1.7
Page 45 of 423
May 2010
Draft
If you are installing on a 64-bit Vista or Windows 2008 Server system, follow these
instructions. There are two major steps in this process: install 5000.1.0, then install
5000.1.7.
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
Right-click and select
Run as administrator
Draft
You are still prompted for Admin login:
5000.1.7
Page 46 of 423
May 2010
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
n Third-Party Install: Logged in as Admin, Not Administrator error
•
Login again, this time as an Admin, not Administrator.
•
Right click on Third Party Setup.exe and Run as Administrator:
•
You are still prompted for Admin login, but no login is required. Click Allow.
Click Allow.
5000.1.7
Page 47 of 423
May 2010
Draft
Right-click and select
Run as administrator
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
n Third-Party Install: Program incompatibility error
You may see this error, indicating a Program incompatibility.
Draft
• Click This program installed correctly.
• Right click on EDM Setup.exe and Run as Administrator.
5000.1.7
Page 48 of 423
May 2010
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
Right-click and select
Run as administrator
Draft
• You are prompted again for permission. Click Allow.
.
Click Allow.
5000.1.7
Page 49 of 423
May 2010
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
• Right click on Drilling Setup.exe and Run as administrator.
Right-click and select
Run as administrator
Draft
You are prompted again for permission. Click Allow.
5000.1.7
Page 50 of 423
May 2010
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
n Drilling and Completions Install: on reboot errors
After the Drilling and Completions Install, click Yes when prompted to reboot. On reboot,
the following errors occur:
• After reboot—SQL Server fails (64-bit only):
Draft
and
5000.1.7
Page 51 of 423
May 2010
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
and
Draft
and
• After reboot—Applications fail to launch (64-bit only). That’s OK; it will all be fixed
after you install the 5000.1.7 update.
Step 2. Install EDT 5000.1.7
This install consists of a self-extracting WinZip® file which includes all the updated files to
apply the required files to your system.
5000.1.7
Page 52 of 423
May 2010
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
1. Make sure that EDT 5000.1.0 or higher has previously been installed. It is prudent to
make a back up of your database files at this time.
2. Make sure that no EDT applications are running when you run this install including
Windows Services e.g., SAM, EPS.
3. Run R5000_EDT_5000.1.7.0.exe. and log in as an admin user (not the machine
Administrator). You are still prompted for Admin login:
Draft
4. Wait for the "5000.1.7.0 Install" window to appear. Click the OK button to begin or
Cancel to cancel the installation.
5. A second "WinZip Self-Extractor" window will open. Select Setup to proceed, Cancel
to stop the installation. 

This application will extract the updated and additional files required to a temporary
directory. and install the files being updated. A DOS Window will appear prompting
you to continue (start) the install process. Press any key to start the install. The DOS
window will then show patch install progress for each file updated in this patch.
6. The next screens involve an End-User License Agreement (EULA) between
Landmark and you, the licensee. Follow the prompts to read the agreement. At the
5000.1.7
Page 53 of 423
May 2010
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
end of the agreement, you are asked whether you accept or decline the terms within
the EULA.
Specify A to accept the agreement, and then press Enter.
IMPORTANT: Specific keyboard input is required to complete the installation
Only “A”, “a”, “ACCEPT”, “Accept”, or “accept” (without the quotation
marks) is allowable input to continue the installation.
7. The pertinent updated files will be installed. This will take a few minutes.
8. Your system will be checked to see if you have Microsoft Visual C++ 2005 SP1 and
2005 Runtime Libraries installed. If not found, you will be prompted to read and
accept an End User License Agreement for these packages. Click Yes to proceed
and install them (if you do not accept, the install will abort).
9. Your system will be checked to see if you have MSXML 4.0 SP2 Parser and SDK. If
not found, you will be prompted to set it up by clicking Next in the Wizard and
accepting the EULA (if you do not accept, the install will abort). Follow the Wizard
prompts to install this package now. Click Finish when complete.
10. Your system will be checked to see if you have Crystal Reports XI SP3 installed. If not
found, it will be installed.
11. After a few minutes, your system will be checked to see if you have SQL Server
Express 2005 (32-bit) installed:
• If it is found, you will skip to Step 12.
• If it is not found, your system will be scanned for SQL Server 2008 (64-bit). If SQL
Server 2008 (64-bit) is found, you will skip to Step 12. If neither SQL Server 2005
Express nor SQL Server 2008 are found, you will be prompted “Would you like to
install SQL Server 2005 Express on this machine Y(yes) or N(No)?” Type Y to install
32-bit SQL Server 2005 Express. Note: if you only use Oracle for your database,
you may elect not to install SQL Server Express 2005. If you type N, the EDT
installation will continue, without installing SQL Server Express and Management
Studio components.
12. Your system will be checked to see if you have SQL Server Management Studio
installed.
5000.1.7
Page 54 of 423
May 2010
Draft
To decline the agreement, press D and then Enter. This will cancel the installation and
abort the EDT update.
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
• If not found: You are prompted to install the SQL Server 2005 Express/
Management Studio components.
When the ‘SQL Server Management Studio Express’ wizard opens, click Next.
When the EULA appears, accept it and click Next; when the Registration
Information screen appears, fill in your information and click Next; when the Feature
Selection screen appears, click Next; when the Install screen appears, click Install.
When the installation is complete, click Finish.
Rarely, a registry error might appear, which you should ignore:
Draft
Ignore this error
5000.1.7
Page 55 of 423
May 2010
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
During the SQL Server Express 2005 install, you may see this error message:
Draft
SQL Server Express 2005 will install correctly if you
click the Run Program button
13. Your system is checked for the SQL Server Backward Compatibility fix. If not found,
the ‘SQL Server Backward Compatibility Setup’ wizard opens. Click Next. When the
EULA appears, accept it and click Next; when the Registration Information screen
appears, enter your information and click Next; when the Feature Selection screen
appears, click Next; when the Install screen appears, click Install. When the
installation is complete, click Finish.
14. You are prompted “Would you like to create desktop shortcuts (Y/N)?” Specify Y to
create shortcuts; specify N if you don’t want shortcuts placed on the desktop.
15. Next you are prompted “Would you like to install EDM Historian now (Y/N)?”, which is
required by the OpenWells and PROFILE Data Approval feature. Specify Y to install
EDM Historian; specify N if you do not want to install EDM Historian.
Just for your information, you are informed that you may need to update your database
to support the 5000.1.7 release. (The location of the appropriate .exe scripts used to
upgrade the SQL and/or Oracle databases, respectively, are displayed.)
16. You are prompted “Would you like to run SQL Server Utilities (SSUTILS) now (Y/N)?”
This allows you to create a SQL Server Express database instance. If you just need
to update the database, specify N and proceed to the next prompt. (Note that
specifying Y and electing to replace a database file will overwrite an existing
attached database.) Specify Y if you have another SQL Server/SQL Server Express
database that you want to attach, or if this is a new database.
5000.1.7
Page 56 of 423
May 2010
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
17. You are prompted to run the update for SQL Server and/or Oracle databases; specify
Y (yes) or N (No) options appropriately each time you are prompted. If you select Y
for either database type, a WinZip Self-Extractor window opens. Click Unzip to unzip
files; click OK when finished unzipping.
Upgrading your SQL Server Database
If you have SQL Server 2008, you will have to attach the EDM database
to your SQL Server 2008 instance using the EDM Database Creation tool
(refer to the 5000.1.0 version of the EDM Drilling Database Guide for
details).
Click Unzip to unzip the
files
The Database Update Program window opens (it may open behind the open Cmd.exe
window).
5000.1.7
Page 57 of 423
May 2010
Draft
Note that 5000.1.3 was the first time that 64-bit operating systems were
supported for an EDT release; prior to that release there were no
previously existing SQL Server Express 2005 installations on the box—so
there was nothing to update. 

If you did not elect to run SSUTILS earlier in the install

Once the EDT 5000.1.7 patch has finished running, if you want to have a
SQL Server Express 2005 database installed locally, you need to go to
Start Menu > Programs > Landmark Engineer's Desktop 5000.1 >
Tools and select the SQL Server Utility. All you do is enter is the
Database Name, i.e. 'edm' or any other name, and then press OK,
accepting the default values for all the other selections.
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
18. If you are updating an Oracle database, you must run the HIST_TBS.SQL script
prior to upgrading the database. The script is extracted to the EDT installation
directory in the EDM\Updates\Oracle\EDM_5000_1_7_Update folder.
Draft
Important if you are running
an Oracle update
Click
19. For either SQL Server or Oracle, click Run Automated to update your 5000.1.0 or
higher database to 5000.1.7.
20. You will be prompted to login as System Administrator to update the database (for
SQL Server 2005 Express, this is sa; for Oracle, you will be prompted to login as the
schema owner, which is edmadmin by default).
Enter the System Administrator User Name and Password. The default password for
sa user is Landmark1; for Oracle the default user name shipped by Landmark was
5000.1.7
Page 58 of 423
May 2010
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
edmadmin and the password was Landmark1 (check with your system administrator to
see if the user name and password have been changed). Select the DSN (Data Source
Name) from the dropdown list (e.g., EDM 5000.1 Single User Db for SQL Server) and
click OK.
21. You will be prompted as follows (version number will change depending on what
version you currently had installed):
Draft
22. Click Yes to continue. The following screen opens, showing the update in progress:
When the update concludes, click OK. The DOS window reports that the 5000.1.7
code changes were successfully installed.
23. You are prompted to press any key to exit out of the DOS session. Please review the
information in the DOS window to ensure no errors were reported. After pressing any
key, the temporary patch install directory will be deleted.
24. This concludes the patch/update installation. Next, perform the required postinstallation tasks, outlined on page 60.
5000.1.7
Page 59 of 423
May 2010
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
Troubleshooting the Installation
If you run into problems, please refer to the “Installation Troubleshooting” section of the
EDM™ Software Installation Guide or the EDT™ Drilling Software Installation Guide.
Microsoft SQL Server Express 2005 Install Behavior With SQL Server
2008 Client/Server 2008
Microsoft SQL Server Express 2005 installation issues impacting PCs with
SQL Server installed are listed in “Microsoft SQL Server Express 2005
Installation Issues” in the EDM Installation Guide.
Post-Installation Required Tasks
1. Before attempting to run the PROFILE application, if you need to export PROFILE
WallPlot Composer schematics to JPG file format, Windows color depth should be
adjusted to a resolution higher than 256-bit.
2. Remember to reboot your computer before attempting to use the Engineer’s Desktop.
Note: On 64-bit machines, you still need to select 32-bit drivers for
EDT software.
On 64-bit machines, you need to go to a different location than in the past
to launch the ODBC Administration dialog. Do not use the
Control Panel> Administrative Tools> Data Sources (ODBC)—instead,
browse for and launch the ODBCAD32.EXE from the
WINDOWS\SYSWOW64 folder.

\Windows\SysWOW64\odbcad32.exe
5000.1.7
Page 60 of 423
May 2010
Draft
Microsoft SQL Server Express 2005 (Microsoft’s replacement for MSDE)
is the standalone database provided with the Engineer’s Desktop 5000.1.7
release. Microsoft SQL Server Express 2005 is a technology that provides
local data storage that is compatible with Microsoft SQL Server 2008. It is
designed and optimized for use on smaller computer systems, including a
single-user computer or small workgroup server.
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
Site Configuration File Import Required Post-Install
Landmark configurations (site configuration files) are contained within the EDM database
and installed with the Microsoft SQL Server 2005 Express database. These files contain
default and customized configurations for EDM Output Reports, OpenWells Preview
Panes, OpenWells Data Entry Forms, OpenWells Shortcut Bars, and Administration
Utility input screens.
If you are upgrading from a previous version of the database, both Oracle and Microsoft
SQL Server 2005 Express (replacement for MSDE) users will have the latest configuration
files imported automatically; you do not have to do anything. Skip to Workspaces and
Templates Import Required Post-Install on page 62.
1. Launch the EDM Administration Utility.
2. Create a database connection for the upgraded database (i.e., use the File > New >
Data Source command).
3. Login to the installed database as edm/Landmark1 (user name/ password).
4. Select the Database icon in the hierarchy for the opened EDM Data Source.
5. Follow the menu path, Tools > Import and Export.
6. Select Import configuration data from local directory.
7. Click Next.
8. Use the Browse button to navigate to the top level directory (i.e., <install
directory>\EDM\Site Configuration Files) and click OK.
9. Leave the path to the XML file descriptor blank. This will cause the default
files_descriptor.xml file to be used. The XML file descriptor (files_descriptor.xml)
populates specific columns in the table that would normally not be populated.
10. Activate the checkbox to overwrite existing files in the EDM database.
5000.1.7
Page 61 of 423
May 2010
Draft
If you have a new Oracle installation, you must import site configuration files after building
a new database. Site configuration files are imported using the EDM Administration Utility.
For an Oracle database creation, these configuration files must be imported using the EDM
Administration Utility. The files are located in the following folder once the installation is
complete: <install directory>\EDM\Site Configuration Files. The procedure to import
these files follows.
Installation: 64-Bit Operating Systems
EDT™ Release Notes
Go To “What’s In This Release?”
11. Click Finish. Once the import is complete, the ImportResults.log file appears. This file
summarizes the results of the import. The beginning of the file states how many Site
Configuration files are to be imported (e.g., 659 files). The end of the file states how
many files were imported. These two numbers should be the same. If there is a
discrepancy between these numbers, contact Landmark Support. The
ImportResults.log file is located in the <EDM install directory>\Common Files folder.
12. Close and then re-open the to view the newly imported files, which are now visible.
Workspaces and Templates Import Required Post-Install
1. In the EDM Administration Utility, select the Oracle database in the tree, then select
Tools > Import and Export. The Import and Export Wizard will open.
2. Use the “Import System Workspaces” option in the Wizard to import workspaces
and templates.
This concludes the installation of EDT software on 64-bit systems.
5000.1.7
Page 62 of 423
May 2010
Draft
Following the installation of EDT 5000.1.7, system workspaces and templates for
applications such as WELLPLAN, StressCheck, CasingSeat, and WELLCAT are
automatically uploaded to SQL Server databases, but will need to be imported to Oracle
databases.
Licensing
EDT™ Release Notes
Go To “What’s In This Release?”
Licensing
Landmark's Application Manager (LAM) is the license system used to control access to
Landmark applications. LAM is based on Macrovision's FLEXnet Publisher. LAM version
5000 is required for release 5000.1.0 and higher. You do not need to re-license for this
release; your 5000.1.0 licenses will work. Refer to the EDT™ Software Version 5000.1.0
Summary Level Release Notes for licensing details.
Accessing Both 2003.x and 5000.x EDT Releases
LM_LICENSE_FILE : c:\landmark\lam\license2003.dat;
\\remote_machine\c:\landmark\lam\license5000.dat;
Make sure that the 2003 license is the first one specified in the path.
Mobile Checkout
LAM 5000.1.7 for Windows includes a utility called Mobile Checkout, which allows you to
“Borrow” (temporarily check out) a network license to use when a computer, such as a
laptop, is disconnected from the network. Performing a Borrow writes encrypted
information on your laptop which preserves a mobile license for the user when
disconnected from the network. The license can then be used on an individual computer
for a time specified when the user checks out the license. The license is returned to the
server licenses when either the user uses the early return procedure or the specified time
limit is reached. When a license is checked out the number of available licenses on the
server is reduced by one. All Drilling applications except OpenWire® Client, OpenWire®
Server, and Well Cost™ can utilize the “Borrow” feature in the Mobile Checkout utility. For
more information, refer to the LAM Guide—Linux, Solaris, and Windows.
Instructions for using the Mobile Checkout feature are in the LAM Guide—Linux, Solaris
and Windows.
5000.1.7
Page 63 of 423
May 2010
Draft
Only one LAM server can run per machine. If access is desired to both 2003.x and
5000.x Engineer’s Desktop applications, then LM_LICENSE_FILE must point to two
distinct LAM servers: either one local and one remote, or two remote servers. The license
path to the LAM 2003 Server must precede the path to the LAM 5000 Server, separated
by a semi-colon, in LM_LICENSE_FILE. For example (all on one line):
Licensing
EDT™ Release Notes
Go To “What’s In This Release?”
Mobile Checkout fails to remove the Registry entries left behind after the borrowed licenses
expire.
This is a known FLEX issue, and should be resolved in future releases of FLEX.
To remove corrupted or expired Borrow entries from the Borrow client machine registry:
1. Run regedit.exe.
2. Go to HKEY_CURRENT_USER\Software\FLEXlm License Manager\Borrow.
3. Delete the "infoborrow" key and contents.
Draft
3a. Delete any other remaining keys and contents (one per feature that is readable).
4. NOTE: If you do this by mistake with active borrows, you will need to wait until they expire at the
server before you can get the client and server synchronized again.
5000.1.7
Page 64 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Enhancements, Fixed Issues, and Known Issues
Descriptions of Enhancements, Fixed Issues, and Known Issues for the applications in the
EDT software suite are provided.
To go directly to the enhancements, bug fixes, and known issues for individual
applications, click on the blue links below:
CasingSeat™
COMPASS™
Draft
Data Analyzer™
EDM™
Engineer’s Desktop™
(EDT™)
OpenWells®
PROFILE™
Real-Time View™
StressCheck™
WELLCAT™
Well Cost™
WELLPLAN™
5000.1.7
Page 65 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
CasingSeat™ Software, Release 5000.1.7
Enhancements
Fixed Issues
Known Issues
The 5000.1.7 release includes all 5000.1.3 supported platforms, plus enhancements,
fixes, and known issues from the 5000.1.0 and subsequent EDT releases. There were no
additional changes made to the CasingSeat software for the 5000.1.7 release.
The CasingSeat enhancements and new functionality for releases 5000.1.0 through
5000.1.7 are described below.
Release 5000.1.7
There are no enhancements to CasingSeat software for the 5000.1.7 release.
Release 5000.1.6
Workspaces
Workspaces—User and System workspace functionality previously available only
in WELLPLAN has been added to WELLCAT, StressCheck, and CasingSeat. A
workspace is a layout that defines how you want tabs, panes, arrangement of plots
within panes, etc. to appear in the software application.
User and System
Workspaces
5000.1.7
Page 66 of 423
May 2010
Draft
CasingSeat Enhancements and New Functionality
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Unlike templates, workspaces do not include data, but only the display
configurations that control the look and feel of the interface.
System Workspaces are read-only, and are shipped with the EDM database. You
may apply them, but not alter them. Additional System workspaces can be
imported using the EDM Administration Utility. When you import System
workspaces, the existing System workspaces are retained.
User Workspaces can be created, changed, or deleted at any time. Importing user
workspaces is an add/replace function; that is, if the name already exists on the
target, the imported workspace will overwrite it.
Draft
Release 5000.1.5
There are no enhancements to CasingSeat software for the 5000.1.5 release.
Release 5000.1.4
There are no enhancements to CasingSeat software for the 5000.1.4 release.
Release 5000.1.3
•
New platforms are supported.
•
Mobile Checkout licensing feature was added.
Release 5000.1.2
There are no enhancements to CasingSeat software for the 5000.1.2 release.
Release 5000.1.1
WELLCAT was added to the EDT suite of applications for the first time in the 5000.1.1
release. Also, some Common Well Explorer enhancements were made. (See EDT™
Software for details). This update release improves the import/export and sharing of
Grades, Pipes/Connections between StressCheck and WELLCAT, improves the
integration between StressCheck and WELLCAT, and repairs critical defects affecting
key StressCheck and WELLCAT application functions. There were no additional
enhancements for the CasingSeat software.
5000.1.7
Page 67 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.0
The 5000.1.0 release of Engineer’s Desktop supports the Microsoft Vista operating
system, has new LAM (FLEXnet Publisher) licensing and contains some critical bug fixes.
Well Cost was added to the EDT suite of applications for the first time in this release. For
the CasingSeat application, there are no additional enhancements.
CasingSeat Fixed Issues
The CasingSeat issues fixed for releases 5000.1.0 through 5000.1.7 are described below.
Draft
Release 5000.1.7
No CasingSeat issues have been fixed for the 5000.1.7 release.
Release 5000.1.6
Defect No.
Description
819193
CasingSeat fails to launch/display “no valid license” with expired bitlock/nodelocked
license file.
Release 5000.1.5
No CasingSeat issues have been fixed for the 5000.1.5 release.
Release 5000.1.4
The following issues were fixed for the 5000.1.4 release of CasingSeat software.
Defect No.
Description
810162
Update current message in reference to well inclination higher than 90 degrees.
810332
Modify CasingSeat template to allow selecting pore and frac tables in read-only
mode.
Release 5000.1.3
CasingSeat fixes from the 5000.1.2 release are included in the 5000.1.3 release. No
additional fixes have been made.
5000.1.7
Page 68 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.2
CasingSeat fixes from the 5000.1.1 release and the 5000.1.1.1 patch are included in
the 5000.1.2 release.
Defect No.
Description
785576
Right-click Save from the Well Explorer causes CasingSeat to crash. (fixed in
5000.1.1 Build 1598)
788402
CasingSeat checks out an EDM license when other EDT applications already have
a license checked out. (fixed in 5000.1.1 Build 1598)
Draft
Release 5000.1.1
CasingSeat fixes from the 5000.1.0 release are included in the 5000.1.1 release. No
additional fixes have been made.
Release 5000.1.0
The following CasingSeat issues were either fixed or have workarounds for the 5000.1
release.
Defect No.
Description
753088
Differences in Layer Type of Lithology causes application crash.
768242
Datum Shifts - Slant Well Behavior - Design incorrectly opens at a new datum
although a warning correctly tells the user that the Design can be opened at the
original datum only.
770521
Licensing - EDT software Licensing does not take advantage of the functionality
that will warn users that their license is set to expire in x days
770907
CasingSeat software does not remember custom changes to spreadsheet column
widths unless the Defaults checkbox is deactivated.
Workaround: To preserve custom column width configurations, deactivate the
Column Widths “Defaults” checkbox on spreadsheet Properties.
779007
Save As - Crash when performing a Save As operation with some Designs.
782288
File Import (PDI file) does NOT respect EDM security tokens
5000.1.7
Page 69 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
CasingSeat Known Issues
The following CasingSeat known issues for releases 5000.1.0 through 5000.1.7 are
described below.
Release 5000.1.7
There are no additional CasingSeat known issues for the 5000.1.7 release.
Release 5000.1.6
Draft
There are no additional CasingSeat known issues for the 5000.1.6 release.
Release 5000.1.5
There are no additional CasingSeat known issues for the 5000.1.5 release.
Release 5000.1.4
There are no additional CasingSeat known issues for the 5000.1.4 release.
Release 5000.1.3
There are no additional CasingSeat known issues for the 5000.1.3 release.
Release 5000.1.2
There are no additional CasingSeat known issues for the 5000.1.2 release. There are
no CasingSeat known issues in the 5000.1.1.1 patch that rolled up into the 5000.1.2
release.
Release 5000.1.1
There are no additional CasingSeat known issues for the 5000.1.1 release.
5000.1.7
Page 70 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.0
The following are CasingSeat known issues for the 5000.1.0 release.
Description
83739
Design Constraints Upper curve is not drawn correctly.
105286
Switching to metric with manual x-scale settings yields a blank Design Plot.
105652
Need validation for X Grid Steps on Scaling Tab of Properties for Design Plot.
105659
Need more validation for True Vertical Depth in Design Parameters.
139659
Some casing schemes are being generated w/ 2 strings the exact same length.
153225
F1 brings up wrong Help topic on the Print Preview window.
155298
CasingSeat software does not allow users to delete cells in the Drilling Parameters
table.
155753
CasingSeat software should not display the Datum Adj. Warning Message if the 
New Datum = Old Datum.
161353
Unnecessary error message appears when tabbing from cleared field in Pore
Pressure spreadsheet.
161354
Unnecessary error message appears when tabbing from cleared field in Fracture
Gradient spreadsheet.
161626
The Design Plot pore pressure curve still plots although a blank record is inserted in
the Pore Pressure spreadsheet.
161630
Design Constraints Lower Curve displays in Design Plot displays when is should
not.
621698
Changing unit systems changes casing names in the Well Schematic but not in the
solutions drop down list (prior unit system displays).
625032
Help dialogs no longer dismiss with the Escape key.
625041
Inconsistent 'Always on Top' behavior for HTML Help dialogs.
625067
The Print dialog now has a non-working Help button where there had been no Help
button before.
625069
The Print Setup dialog now has a non-working Help button where there had been
no Help button before.
625805
CasingSeat software fails to release about 5 MB memory after closing a Design.
630745
Well Schematic leaves a PROFILE.log file in the current working directory.
700006
CasingSeat software grabs an additional 5 to 20 MB memory for each Save As
operation performed.
700110
Section View - Vertical scaling does not work correctly when the view is split
vertically.
5000.1.7
Page 71 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
721022
Missing item in dialog list.
724265
Cannot successfully save Audit Info under Well or Wellbore when a Design is open.
728689
Missing data dictionary button and menu item in CasingSeat software.
728867
CasingSeat software uses 6 to 8MB more memory at any given state than it did in
version 2003.14.1.0.
729354
Find toolbar button stays depressed and the Find menu item appears checked for a
long time after the Find dialog is closed.
729360
Non-results dependent report items should print only once instead of repeated for
each solution.
729857
Unwanted Well Explorer movement - loss of focus with Unit System changes.
730379
Casing and Hole Size Selector - Context menu lacks Maximize and Restore
functions.
730900
Adding a new casing to the highest (48”) hole causes CasingSeat software to
crash.
730984
Casing and Hole Size Selector - There is no report item for this new view.
731048
Accessing the Unit System Editor dialog can later cause the Open Template dialog
to hang or prevent Designs from opening.
731054
Crash applying a newly imported template to a particular newly imported Design in
a new, empty database.
741673
Well Schematic overlaps into any neighboring pane in Print Preview of Current Tab.
744925
Hole Sizes entered in PROFILE software are not displayed in CasingSeat software.
744945
Changes in the Hole Size made in PROFILE software are not displayed in
CasingSeat software or COMPASS software.
745832
First hole section MD Top depth displayed in PROFILE software is incorrect and
should start at the depth where the earth begins.
745843
All MD Top and MD Base depths displayed in PROFILE software are greater than
they should be by the value of the Datum.
746660
Updating the Active Casing Configuration in CasingSeat software can cause old
Hole Section records to be left behind.
746696
In the Well Schematic, casings appear to violate the boundaries of surrounding
casing strings when the Non-Deviated option is unchecked.
747254
Missing menu command: Virtual Folders.
747733
Correct delimiter is not immediately displayed in the plot views. Possible refresh
issue.
747737
Date format in reports header does not change based upon selected Regional
Settings.
5000.1.7
Page 72 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
748555
Odd Registry entry appears in HKCU when using Norwegian (Nynorsk).
753078
Refresh is required in Well Schematic to display it correctly.
753388
Applying a template to a Design does not set the state of the Design as one that
contains unsaved changes.
753399
In the Casing and Hole Size Selector, nodes can be drug into invalid locations
when a template is applied to a Design.
757396
Undo button active just after a Design is opened.
760391
CasingSeat software does not set CD_ASSEMBLY.plan_depth_type.
762310
CasingSeat software crashes when attempting to add additional temperature data.
768882
No exclamation sound is heard as expected when the application prompts the user
to save.
769218
Well Schematic does not generate until the user deliberately re-selects it from the
menu when running CasingSeat software on Microsoft Vista.
769740
Border Thickness in Well Schematic in CasingSeat application is different from the
2003.16.1.0 release.
771513
CasingSeat software crashes when performing an export via DEX™ software from
some Designs.
773629
The symbol size of Casing Shoe shows twice the size of the 2003.21.0 release in
the CasingSeat and StressCheck™ applications.
776574
Allowable Hole Size and Allowable Casing OD's spreadsheets are not validated
after a Template import unless the user knows to press the Calculate button.
776700
Print Range is no honored when printing reports.
778773
CasingSeat software does not load a wellpath trajectory created in PROFILE
software.
779367
Differences in Well Schematic and Casing and Tubing Schemes.
783812
Intermittent “Memory could not be read” error while running CasingSeat software
on Citrix.
5000.1.7
Page 73 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
COMPASS™ Software
Enhancements
Fixed Issues
Known Issues
The 5000.1.7 release includes all 5000.1.3 supported platforms, plus enhancements,
fixes, and known issues from the 5000.1.0 and subsequent EDT releases. Bug fixes were
made to the COMPASS software for the 5000.1.7 release.
The COMPASS enhancements and new functionality for 5000.1.0 through 5000.1.7 are
described below.
Release 5000.1.7
There are no enhancements to COMPASS software for the 5000.1.7 release.
Release 5000.1.6
There are no enhancements to the COMPASS 5000.1.6 software.
Release 5000.1.5
•
Includes a new Report Manager version, which will reduce memory consumption
and contains various improvements for report generation.
Release 5000.1.4
•
The COMPASS software can be configured to send an email notification indicating
when an anticollision alert has been triggered. This functionality allows you to:
•
Specify the required anticollision criteria for generating anticollision email
notifications using the Anticollision Alerts Tab.
•
Define Partners and Contacts using the Partners Tab (Company Properties
Dialog).
•
Indicate which Contact(s) should receive an email anticollision notification for a
particular well using the Associated Partners Tab (Well Properties Dialog).
5000.1.7
Page 74 of 423
May 2010
Draft
COMPASS Enhancements and New Functionality
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
Determine the offset well generating the alert using several methods, including:
•
Ranging tools can now be used in the COMPASS software. To use a ranging tool,
specify the accuracy of the tool (as a %) over a specified radial distance. When the
distance between the wells is less than the specified radial distance, the ranging
tool accuracy will be used on the anticollision reports and plots. If the distance
between the wells is greater than the specified radial distance, the accuracy of the
tool specified in the Survey Program will be used. For more information, refer to
‘Using Ranging Tools’ in the online Help.
•
It is now possible to specify the MD, Inclination, Azimuth, TVD, N/S, and E/W for
one or more survey stations within the Survey Editor. The remaining survey
stations can be input using MD, Inclination, and Azimuth. 

To specify MD, Inclination, Azimuth, TVD, N/S, and E/W for one or more survey
stations:
•
— First select Normal (SAGD Wells) on the Survey Properties Dialog.
— Then using the Survey Editor, select Tie On as the Station Type for the
survey data point.
BGS has published code and data for a new 20 coefficient model. This has been
incorporated into the COMPASS software.
•
A BGS license feature has been added to the COMPASS software. If you are using
the BGS model in the COMPASS 5000.1.4 software, or later you must have a
license from the BGS to use the model, and a license from Landmark (the
COMPASS license feature is CFWBGS). Note that a Landmark BGS license will
be issued only after verification with the BGS.
•
Default values can be automatically used for data entry fields left blank on the
Survey Editor by setting a configuration option on the Tools > User Setup dialog.
5000.1.7
Page 75 of 423
May 2010
Draft
— The name of the offset well is included in the email notification. (The
separation distance, reference datum, and the measured depth where
the alert is triggered is also provided in the email notification.)
— The name of the offset well is included in a message dialog the
COMPASS software displays when an alert is triggered. (The separation
distance and measured depth where the alert is triggered is also
provided in the message.)
— The name of the offset well will be listed in the Offset Well column in the
Survey Editor. Look for yellow cells in the Offset Distance column
indicating when the distance between wells is small enough to trigger the
email notification. Note: If these columns are not displayed on the
Survey Editor, use View > Show Columns to display the columns. 
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.3
•
New platforms are supported.
•
Mobile Checkout licensing feature libraries were added.
Release 5000.1.2
There are no enhancements to the COMPASS 5000.1.2 software.
WELLCAT was added to the EDT suite of applications for the first time in the 5000.1.1
release. Also, some Common Well Explorer enhancements were made. (See EDT™
Software for details). This update release improves the import/export and sharing of
Grades, Pipes/Connections between StressCheck and WELLCAT, improves the
integration between StressCheck and WELLCAT, and repairs critical defects affecting
key StressCheck and WELLCAT application functions. There were no additional
enhancements for the COMPASS software.
Release 5000.1.0
The 5000.1.0 release of Engineer’s Desktop supports the Microsoft Vista operating
system, has new LAM (FLEXnet Publisher) licensing and contains some critical bug fixes.
Well Cost was added to the EDT suite of applications for the first time in this release. For
the COMPASS application, the following enhancements were made:
•
Formation surfaces are now supported; this includes GOCAD Tsurf files,
OpenWorks faults and fault planes
•
Live graphs have been replaced with Wall Plot Composer-based plots
•
Changes made to Data Boxes will simplify target data selection and add additional
options and controls.
•
The COMPASS application will add appropriate default values if values are not
specified.
•
Definitive Survey locking implemented (see General Integration Enhancements for
details).
•
Implemented the ‘Draw Wellpaths From Sidetrack Depth’ feature for the 3D View.
5000.1.7
Page 76 of 423
May 2010
Draft
Release 5000.1.1
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
COMPASS Fixed Issues
The COMPASS issues fixed for 5000.1.0 through 5000.1.7 are described below.
Release 5000.1.7
The following issues were fixed for the 5000.1.7 release of COMPASS software.
Defect No.
Description
825653
Wallplots do not remember the size of casing shoes.
Draft
Release 5000.1.6
The following issues were fixed for the 5000.1.6 release of COMPASS software.
Defect No.
Description
737187
Issues with low-angle projection
818744
Input and Output Error Confidence Ranges
823645
Wellbore intercepts are not being calculated correctly
825617
Plan Editor: Can’t do free-form editing (insert and edit cells to compute)
825619
Undo Button in plan editor does not work more than 1 undo.
825623
The new method of zooming and tracking of well trajectory is not convenient in
COMPASS 5000.1.5 (Toggle Cross, Toggle Wellbore Center, Set Center).
825646
Template Slot Editor: can’t change names of individual slots.
825655
Survey Editor AC Columns: Toolface, XY offset columns are wrong (inverted)
825656
Sperry-Type Ellipse separation is wrong when the ellipses overlap
825657
Problem with Inertial surveys tied and spliced in survey program, incorrect
coordinates
825658
Sperry want Project Ahead to work against driller’s target (where present), not
standard target
5000.1.7
Page 77 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.5
The following issues were fixed for the 5000.1.5 release of COMPASS software.
Defect No.
Description
807857
COMPASS does not update SC_WELLBORE.ko_md (Kick Off MD), resulting in
PROFILE updating CD_DEFINITIVE_SURVEY_HEADER.ko_md (the definitive
survey MD Kick Off) with the wrong value.
810813
Some XY Graphs show jagged lines with Wellpath Smoothing turned on.
812030
Nudging a locked target ignores user input inclination or azimuth.
Draft
Release 5000.1.4
•
The following COMPASS issues were either fixed or have workarounds for the
5000.1.4 release:
Defect No.
Description
613899
Vertical Section will let you save a null azimuth
613901
Vertical Section: allows duplicate entries for the same TVD
726056
Crash when entering a very large MD in Plan Editor
752848
Unit Editor not showing the COMPASS active unit set in dropdown menu
770416
Live Link: not importing "manual planning" sections from TracPlanner when Auto
Export Plan on save is active
772293
COMPASS crashes when plots containing polylines are selected and deleted
775804
Surface Properties widgets should be disabled until a surface is selected
780204
Wall Plot Template: Default settings are not saved
781831
AUTO: Icons in the 3D View menu are not displayed properly
783908
Delete Point from Line functionality in Section and Plan views can disable plots.
783919
Wellpath selected in Legend is not highlighted in Section / Plan or 3D view
784293
Data Box in a Wall Plot Composer file that includes a 'Plan Section Annotations'
Data Type from 2003.16 is not parsed in 5000.1
784318
Data Box in a Wall Plot Composer file that includes a 'Wellbore Targets Map
TVDSS' Data Type from 2003.16 is not parsed in 5000.1
784361
Error models can be imported into a locked Company.
784429
When a gyro survey is run back into the original well, COMPASS 2003.16 doesn't
seem to work properly.
5000.1.7
Page 78 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
784852
Reference design is not shown in offset selection dialog if it has no program and
you filter out designs with no program.
785487
Plots don’t show the current Plan row selected in red
785489
Plots don’t change if Unit System is changed in main application dropdown menu
785497
Systematic Error tied onto ISCWSA gives incorrect depth error component
786495
COMPASS crashes when user displays graph objects properties in the Wall Plot
Composer.
786574
Large number of change history records slows down the Well Explorer
786726
For new surveys, the default tie-on for a survey is from wellhead; it should be from
the last survey (when present)
786730
Use of TBR is inconsistent in anti-collision calculations with different error models
786733
For a sidetrack, if the Tie Back option is chosen, so that user can enter sidetrack
depth, it’s not possible to recover the original hole surveys in the survey program
786736
Multiple datums are allowed with the same name--this is an integration issue
786739
With new wellbore, the tie sidetrack is not filled in (default) like in COMPASS 2000
786741
Oracle: Unable to see projects in COMPASS Well Explorer tree when use_risk field
is not NULL.
786743
Locking a survey via the properties dialog in the Survey Editor does not save or
enable the Save button.
787280
Risk Separation Factor and Probability of Collision columns are blank in the report.
787284
Change a line in the Wellpath Editor - Azi from 50 to 47 deg in line 7.
788322
Plan Editor MD should retain MD not CL for projections if ST depth changes (as an
option)
788401
COMPASS Recalculate truncates some WELLPLAN/StressCheck Prototype
Designs to RKB
788458
Standard wall plot data boxes are poor quality - need to be improved
792404
Need Help with COMPASS
793027
COMPASS is overwriting time portions of stored date with midnight
796927
Horizontal Drillers Target Different in 2003.21
796931
Projection created from Survey Editor - Project Ahead will not compute when saved
and opened in Plan Editor
796943
COMPASS plots go out of bounds when sent to a printer or a PDF printer
799256
Magnetic Model not using NADCON type calculations for Lat/Long to WGS84
800938
COMPASS Survey Editor does not refresh after a SAM reload message is accepted
5000.1.7
Page 79 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
800966
COMPASS crashes when Survey Properties OK'd after receiving SAM notification
that the survey header was changed by another application.
802796
Need support for the MGRS geodetic system
803558
When casings are added to the error radii in the ratio calculation, we need to display
this on the AC report
803612
Map <--> Lat/Long conversions are incorrect for geodetic systems with a PM shift.
804053
Targets do not get imported when plan is imported over an existing plan
804687
Unit set selection not staying selected.
804688
Shifting associated site data message on the site properties
804689
Cannot unassign a target on a plan after Save As
804690
BP engineer (who does not have rights to create a Principal Plan) is able to do so
within EDM COMPASS 2003.16.1.17
804691
Datum shifts from default to another datum when create a new plan by using
Lookhead (Actual+Plan)
805204
Depth Ratio is not working correctly. No one uses it, should be eliminated.
805214
The maximum dogleg is stored in the CD_SURVEY_HEADER_T table, it's depth
CD_SURVEY_HEADER_T.maximum_dls_depth needs to be stored as per System
datum (usually MSL).
805497
A plan created using Optimum Align option in the Project Ahead dialog box doesn't
get saved properly and gives error message on reopening. Note: this problem is
also seen in EDM 5000.1.2, COMPASS build 33.
805807
Multi-Design Export using Interpolate Interval TVD has issues; first well's data OK,
the ones to follow do not interpolate or contain no data at all.
806175
The planning method (Nudge) DLS, INC, AZI (Const-TFO) does not work properly
above 60 AZM.
807291
Cannot control color of Additional Survey wellpath lines.
807434
When you interpolate local coordinates from the plan editor, you get incorrect
results
807570
Project Ahead option in Design generates a design labeled as 'No Planned Data'
containing only a tie-on line.
807573
The 'Make Definitive ...' option in the Actual Design Survey Program Tab generates
a 'Survey do not tie back to surface' error
807654
Sperry Ellipse reports wrong North and East error columns - not including surface
error
807659
Re-survey functionality to update dependent wellbore programs with re-survey from
sidetrack
5000.1.7
Page 80 of 423
Draft
Defect No.
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
807661
Magnetic notepad report shows depth below datum, which is confusing; should
show elevation above MSL
807665
When you interpolate local coordinates from the Plan Editor, you get incorrect
results
807666
COMPASS 2003.11 used to do pie-shaped target; COMPASS 2003.16 and
2003.21 cannot do it.
807668
Magnetic equivalent distance line does not include convergent points
807669
Survey Editor Quickscan feature. For SAGD DDs want to be able to select the well
as offset.
807728
Anti-Collision scanning using different plan methods produce different separation
factor results.
807735
Changing the confidence level does not refresh the Anti-Collision report
807770
Error shadow distance in travelling cylinder has issues.
Release 5000.1.3
There are no additional COMPASS known issues for the 5000.1.3 release.
Release 5000.1.2
A COMPASS fix from the 5000.1.1.1 patch was rolled into the 5000.1.2 release.
Defect No.
Description
798462
COMPASS deletes planned survey from other applications (fixed in 5000.1.1.1
Build 33)
Release 5000.1.1
There are no additional COMPASS fixed issues for the 5000.1.1 release.
5000.1.7
Page 81 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.0
The following issues were either fixed or have workarounds for the COMPASS
5000.1.0 release:
Description
781765
2D Varying Curvature plot missing data.
767507
Change History can be turned off using EDM System Setting.
752507
When you perform an Instant Survey in COMPASS, the Well Explorer does not
display anything below Well level. Wellbore and Design are missing until the user
refreshes the Well Explorer tree.
753689
User comments in Change History are not saved.
754232
When saving a Wall Plot Composer template, changes to the lease line color or
adding fill patterns are not saved.
734201
COMPASS does not retain the slot assignment when the slot name is changed.
757457
COMPASS does not honor regional settings for decimal mark.
754687
COMPASS loses survey data when hiding the CL column.
752569
Crash after copied folder is deleted.
753209
Depth slice view in tRaveling Cylinder incorrectly displays errors.
730000
Survey program optimizer incorrectly handled confidence limits for horizontal drilling
targets.
783888
Error in project ahead calculations.
754229
Fill functionality needed on lease line import.
748519
Data will not be imported when using Field Office Transfer to import data created
using Instant Plan in COMPASS because COMPASS does not assign a Tight
group.
754218
Plan data is lost when a target is updated with the Plan Editor open.
749440
Saved well slot assignments created using Optimize are lost when Template Editor
is closed.
781759
Indicate in the online help that Angus Jamieson’s algorithm for Varying Curvature is
used.
5000.1.7
Page 82 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
COMPASS Known Issues
The following COMPASS known issues for releases 5000.1.0 through 5000.1.7 are
described below.
Release 5000.1.7
There are no additional COMPASS known issues for the 5000.1.7 release.
Release 5000.1.6
Draft
There are no additional known issues for the COMPASS 5000.1.6 release.
Release 5000.1.5
There are no additional known issues for the COMPASS 5000.1.5 release.
Release 5000.1.4
There are no additional known issues for the COMPASS 5000.1.4 release.
Release 5000.1.3
There are no additional known issues for the COMPASS 5000.1.3 release.
Release 5000.1.2
There are no additional known issues for the COMPASS 5000.1.2 release.
Release 5000.1.1
There are no additional known issues for the COMPASS 5000.1.1 release.
5000.1.7
Page 83 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.0
The following are known issues for the COMPASS 5000.1.0 release:
Description
716966
Negative air gap for offshore wells when sea level is below MSL (Caspian Sea).
720317
User locked out of properties dialog when another application has a design open in
the case of same user same machine.
726056
Crash when entering a very large MD in plan editor.
729931
COMPASS MD plots do not shift with Datum flip in Datum tool bar.
737594
Cannot create pie-shaped targets.
742632
When a sidetrack is open, original hole annotations are not visible on plots.
753642
COMPASS crashes when adding offsets to lease lines in WPC while working in
hosted environment (i.e. Team Workspace).
754449
Target section missing from COMPASS Custom Survey Report when Design
Targets selected.
754840
Some annotations close to TD are not displayed on plots.
755115
COMPASS crashes after about every 9 to 10 imports.
761308
Survey program optimization not giving correct results.
763154
Deleted Actual plan appears when choosing offset design.
764048
Application crashes while activating wellbore with two surveys open.
765422
COMPASS hangs if deleting a company with large number of projects.
765426
Anticollision results are affected if zero casing is entered.
765480
9i OpenWells causes COMPASS to crash upon closing it.
766902
COMPASS hangs when exporting a site with the find dialog open.
770416
Live Link, not importing “manual planning” sections from TracPlanner when Auto
Export Plan on save is active.
772293
COMPASS crashes when plots containing polylines are selected and deleted.
773397
Oracle: Unable to see projects in COMPASS well explorer tree when use_risk field
is not NULL.
775102
COMPASS crashes on Citrix when creating a lookahead plan or doing a project
ahead from a survey.
777898
Draw wellpath from sidetrack option is not working for 3D Live view.
779594
Using intermediate survey station as “tie in point” has problems.
5000.1.7
Page 84 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
779656
Locking a survey via the properties dialog in the survey editor does not save or
enable the save button.
782153
Error models can be imported into a locked Company.
782441
Unable to delete a project with a large number of pads, wells and targets.
782875
Cannot save or append a projection when you project ahead from an existing plan.
783908
Delete Point from Line functionality in Section and Plan views can disable plots.
784187
Size of fonts in background plots increases each time the active plot is displayed in
print preview or print option selected.
784429
When a gyro survey is run back into the original well, COMPASS doesn't seem to
work properly.
784358
Exported DXF file cannot be loaded into AutoCad.
5000.1.7
Page 85 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Data Analyzer™ Software
Enhancements
Fixed Issues
Known Issues
The 5000.1.7 release includes all 5000.1.3 supported platforms, plus enhancements,
fixes, and known issues from the 5000.1.0 and subsequent EDT releases. There were no
additional changes made to the Data Analyzer software for the 5000.1.7 release.
The Data Analyzer enhancements and new functionality for releases 5000.1.0 through
5000.1.7 are described below.
Release 5000.1.7
There are no enhancements to Data Analyzer software for the 5000.1.7 release.
Release 5000.1.6
There are no enhancements to Data Analyzer software for the 5000.1.6 release.
Release 5000.1.5
There are no enhancements to Data Analyzer software for the 5000.1.5 release.
Release 5000.1.4
There are no enhancements to Data Analyzer software for the 5000.1.4 release.
Release 5000.1.3
•
New platforms are supported.
•
Mobile Checkout licensing feature libraries were added.
5000.1.7
Page 86 of 423
May 2010
Draft
Data Analyzer Enhancements and New Functionality
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.2
There are no enhancements to Data Analyzer software for the 5000.1.2 release.
Release 5000.1.1
Release 5000.1.0
The 5000.1.0 release of Engineer’s Desktop supports the Microsoft Vista operating
system, has new LAM (FLEXnet Publisher) licensing and contains some critical bug fixes.
Well Cost was added to the EDT suite of applications for the first time in this release. For
the Data Analyzer application, the following enhancement was made:
•
Find in Tree Feature: User now has the ability to run a text search against the
Selection Tree. When performing a search of the Selection Tree, you must enter
text that is applicable to the currently selected Tree View.
5000.1.7
Page 87 of 423
May 2010
Draft
WELLCAT was added to the EDT suite of applications for the first time in the 5000.1.1
release. Also, some Common Well Explorer enhancements were made. (See EDT™
Software for details). This update release improves the import/export and sharing of
Grades, Pipes/Connections between StressCheck and WELLCAT, improves the
integration between StressCheck and WELLCAT, and repairs critical defects affecting
key StressCheck and WELLCAT application functions. There were no additional
enhancements for the Data Analyzer software.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Data Analyzer Fixed Issues
The Data Analyzer issues fixed for 5000.1.0 through 5000.1.5 are described below.
Release 5000.1.7
No Data Analyzer issues have been fixed for the 5000.1.7 release.
Release 5000.1.6
Draft
No Data Analyzer fixes were done for the 5000.1.6 release.
Release 5000.1.5
No Data Analyzer fixes were done for the 5000.1.5 release.
Release 5000.1.4
No Data Analyzer fixes were done for the 5000.1.4 release.
Release 5000.1.3
No Data Analyzer fixes were done for the 5000.1.3 release.
Release 5000.1.2
For the 5000.1.2 release, the following Data Analyzer fix was done.
Defect ID
Subject
Comp Level 1
727822
Users need to be able to change Query Timeout value (reported in 2003.14.1.0).
Core App
Comp Level 2
Release 5000.1.1
No Data Analyzer fixes were done for the 5000.1.1 release.
5000.1.7
Page 88 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.0
The following Data Analyzer issues were either fixed or have workarounds for the
5000.1.0 release.
Subject
Comp Level 1
736669
Find Function on Data Analyzer Selection Tree
Selection Tree
746136
Add Stimulation Flow Backs to "DA/DV Well
Explorer mode" tree
Selection Tree
Tree View
763839
Data Analyzer EDM help refers repeatedly to
DIMS
Help/
Documentation
Online Help
770529
Licensing - EDT Licensing does not take
advantage of the functionality that will warn
users that their license is set to expire in x days
Licensing
771959
Data Analyzer Graph wizard dies not recognize
derived or grouped numeric fields as numeric.
Graphics
775701
Table linkage between
DM_OPER_EQUIP_FAIL and DM_ACTIVITY is
wrong.
Core App
776401
Update the Data Analyzer Metadata for Hole
Plan section in the Well Planning Report
Selection Tree
776936
Update Data Analyzer for the new fields added
to the Daily Operation Report's general section.
Selection Tree
782756
Data Analyzer Selection Tree - Closing a query
before closing the Tree Find dialog can cause
DA to shut down.
Selection Tree
5000.1.7
Page 89 of 423
Comp Level 2
Draft
Defect ID
Graph Wizard
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Data Analyzer Known Issues
The following Data Analyzer known issues for releases 5000.1.0 through 5000.1.5 are
described below.
Release 5000.1.7
There are no additional Data Analyzer known issues for the 5000.1.7 release.
Release 5000.1.6
Release 5000.1.5
No additional Data Analyzer known issues were reported for the 5000.1.5 release.
Release 5000.1.4
No additional Data Analyzer known issues were reported for the 5000.1.4 release.
Release 5000.1.3
No additional Data Analyzer known issues were reported for the 5000.1.3 release.
Release 5000.1.2
No additional Data Analyzer known issues were reported for the 5000.1.2 release.
Release 5000.1.1
No additional Data Analyzer known issues were reported for the 5000.1.1 release.
5000.1.7
Page 90 of 423
May 2010
Draft
No additional Data Analyzer known issues were reported for the 5000.1.6 release.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.0
The following Data Analyzer known issues were reported for the 5000.1.0 release.
Subject
Comp Level 1
772574
Need "find" function in Open query windows
Query
782031
Waste Management Tree in Hierarchy should
show the recycling icon used in the OpenWells
Selection Tree
Tree View
783193
Graph Wizard - Just walking through all the
steps enables the Save button even though no
Graphics
Graph Wizard
762100
OpenWells stimulation report copied from
library is not displaying in Data Analyzer
Query
Filter
764319
Data Analyzer - User request ability to break/
stop large query process
Query
771228
2nd (NPT free) line in TvD graph
Graphics
761014
User option under OPTIONS in Data Analyzer
to allow the user to re-map the excel path if the
Core App
720335
Data Analyzer should record and display the
creation and modification date of a query along
Core App
727464
Need a token to allow user to save DA queries
as iWellfile queries.
Core App
727637
Request change to the links between the rig
and the well information.
Query
178704
Need multi-graph print option to print all graphs
Graphics
757262
User wants to add the company logo to the
query reports created with Data Analyzer.
Printing
730479
Graphs in iWellFile have different graphs than
are configured in Data Analyzer
iDIMS Query
733889
IWellFile not showing Date/Time only Date for
Spud Date and Update Date.
Query Results
Spreadsheet
5000.1.7
Page 91 of 423
Comp Level 2
Draft
Defect
ID
Graph Properties
Key Joins
Print Setup
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
EDM™ Software
Enhancements
Fixed Issues
Known Issues
The 5000.1.7 release includes all 5000.1.3 supported platforms, plus enhancements,
fixes, and known issues from the 5000.1.0 and subsequent EDT releases. Changes were
made to the EDM data model to support enhancements and bug fixes in 5000.1.7.
The EDM enhancements and new functionality for releases 5000.1.0 through 5000.1.7
are described below.
Release 5000.1.7
•
Data model changes in support of enhancements.
Release 5000.1.6
•
Data model changes were made primarily in support of Well Cost, as well as a few
enhancements and bug fixes for other products. Contact Landmark Support if you
would like the details of the database changes.
•
EDM AdminUtility—Workspaces in the form of XML files can now be imported as
System Workspaces.
Release 5000.1.5
•
Data model changes in support of enhancements.
Release 5000.1.4
•
Data model changes in support of COMPASS enhancements and OpenWells
(WITSML) were made, as well as a couple bug fixes.
Release 5000.1.3
•
New platforms are supported.
5000.1.7
Page 92 of 423
May 2010
Draft
EDM Enhancements
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
Mobile Checkout licensing feature libraries were added.
Release 5000.1.2
For 5000.1.2 there were EDM data model changes to support the OpenWells 5000.1.2
enhancements. EDM 5000.1.0.1 patch bug fixes were also rolled up into the 5000.1.2
release.
Release 5000.1.1
Release 5000.1.0
The 5000.1.0 release of Engineer’s Desktop supports the Microsoft Vista operating
system, has new LAM (FLEXnet Publisher) licensing and contains some critical bug fixes.
Well Cost was added to the EDT suite of applications for the first time in this release. For
EDM software, the following enhancements were made:
5000.1.7
Page 93 of 423
May 2010
Draft
WELLCAT was added to the EDT suite of applications for the first time in the 5000.1.1
release. Also, some Common Well Explorer enhancements were made. (See EDT™
Software for details). This update release improves the import/export and sharing of
Grades, Pipes/Connections between StressCheck and WELLCAT, improves the
integration between StressCheck and WELLCAT, and repairs critical defects affecting
key StressCheck and WELLCAT application functions. There were no additional
enhancements for the EDM software.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
EDM Fixed Issues
The EDM issues fixed for 5000.1.0 through 5000.1.7 are described below.
Release 5000.1.7
The following issues were fixed or have workarounds for the 5000.1.7 release.
Description
754529
Customising OpenWells Test data entry form layout results in fields disappearing in
form.
800239
Missing alternate currencies against 4 unit classes.
806856
REQUEST: Add new unit to Class 171 aka "Concentration (Chlorides)".
807464
EDM Admin - Property Dialogs changes are not being saved/respected.
812940
System Settings are not included in a Configuration Tranfer export.
Release 5000.1.6
The following issues were fixed or have workarounds for the 5000.1.6 release.
Defect No.
Description
820263
Import Workspaces deletes SCK/CS/WELLCAT templates
821897
A number of picklists on Oracle are defined without Primary Key constraints
Release 5000.1.5
The following issues were fixed for the 5000.1.5 release of EDM software.
Funnel Viscosity (sec/liter) Units Conversion Error
Previous versions of the EDM database incorrectly stored Funnel Viscosity values
entered using the SI unit stem (seconds/liter). This was due to the database using
the inverse multiplier .94635290 when converting the seconds/liter value to
seconds/quart to store in the database. The correct multiplier 1.0566882 is now
used to convert second/liter to seconds/quart.
5000.1.7
Page 94 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Any data previously entered in SI Units is stored incorrectly and must be manually
corrected.
Please contact Landmark support for information on a solution document outlining
the steps to identify and correct this data.
The following fields are affected:
CD_CEMENT_FLUID.viscosity
•
CD_FLUID.viscosity_funnel
•
DM_DST.viscosity
•
DM_PIT_OP.viscosity
•
DM_WELL_PLAN_MUD.funnel_viscosity_max
•
DM_WELL_PLAN_MUD.funnel_viscosity_min
Draft
•
Copy/Paste Performance Improvements
Enhancements have been made to the Copy/Paste operations to improve
performance and memory usage. These issues are most notable in WELLPLAN,
CasingSeat and StressCheck.
Defect No.
Description
796635
Catalog Editor: Duplication of Columns in Casing Connector C. One column needs
to be removed.
803236
User-created System Templates are lost after running the EDT 5000.1.x SQL
database update.
809350
Unit Converter: Funnel Viscosity - incorrect unit conversion.
813922
EDM_GROUP_MEMBERS.child_seq attribute and field names are capitalized in
MD_SYS_ATTR_DICTIONARY.
815211
Copying a well with Tubular applications and WELLPLAN data is taking 10+ hours.
5000.1.7
Page 95 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.4
The following EDM issues were either fixed or have workarounds for the 5000.1.4
release.
Defect No.
Description
810985
The default precision for K’ (consistency index) for the unit lb*s^n’/ft2, is not precise
enough. Fixed: The default precision for K’when using the unit lb*s^n’/ft2 has been
increased by 2 decimal points.
811205
When using SI unit system, default unit for K’ was displayed in lb*s^n’/ft2. Fixed: The
default SI unit for K’ is now Pa*s^n'.
Draft
Release 5000.1.3
No additional EDM issues were fixed for the 5000.1.3 release.
Release 5000.1.2
The following EDM issues were either fixed or have workarounds for the 5000.1.2
release.
Defect No.
Description
175051
Changes to OpenWells status colors do not prompt for Save.
728457
Localization (Russian, Chinese), Creating a Group, and Tight Group in MSDE as
edmadmin/landmark shows ????
782534
EDM Output Reports Visible picklist changed value, Display text modified values are
not updating in the report Config xml file.
783800
WITSML Log Object import and export unit test failing with latest source in StarTeam
784311
EUROLAMBERT geodetic system has incorrect parameters
784588
Clone to add min and max standpipe pressure to DM_BIT_OP and DM_BHA_OP
785078
The function that deletes the temporary files in Working Directory should be added in
Email Configuration of FOT.
785173
Clone of 743415- Need support for Perf Gun w/ Stim Sleeve, Stim Gun Wellbore
Equipment component types. Need to add to default lists and provide PROFILE
symbol for.
785178
Clone of 725892 - Add a new field for “Construction Date". DM_CR_CONSTRUCTION.access_construction_date (date/time - date only).
785180
Clone of 754211 - Need 'OPEN' & 'CLOSED' items added to
MD_PK_COMPONENT_STATUS system picklist.
5000.1.7
Page 96 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
785187
Clone of 705972 - Cement Fluids Calculated Sacks does not have a unit defined should be 'sacks'
785189
clone of 625250 - Need CO2 Concentration field for DST Rates
785192
clone of 731491 - Need Top and bottom TVD for Annular Fluids
785193
clone of 734660 - Could you please increase the length of the field
DM_PERSONNEL, squad_member, in Daily Operations, Personnel.
785195
clone of 760710 - CD_ASSEMBLY_COMP.grade_name and
CD_EXTERNAL_COMP_UMB VIRTUAL FIELD is only 16 chars long where as the
Grade length is 60 chars long
785197
clone of 760725 - CD_WEQP_GAS_LIFT_MANDREL.assembly_comp_name IS 50
chars, but the hard coded picklist's
785200
clone of 731977 - Field for liner top md
785202
clone of 725648 - Nowhere to enter #wellheads on pad or wellhead requirements
description
785203
clone of 721800 - Require new fields in Test Form
785268
clone of 630078 - Need additional Duration columns (3) for Planned Operations
785301
clone of 632731 - Additions for Offshore Marine Currents tracking
785308
clone of 726251 - Need additional equipment components supported for certain
Section Types
785310
clone of 622388 - Field for Max OD in Casing Report
785312
clone of 623207 - Please add Rate of Penetration to the Peak Gas tab of Daily
Geolog Report.
785315
clone of 622729 - Need additional Tubing Pressure field for Flowing Test Sheet
785317
clone of 756041 - Allow zone order in the wellbore properties to be saved
785322
clone of 623206 - Need range of depths for peak gas.
787426
Enhancement request For Field office Data Transfer
787540
clone of 760179 - Additional fields required for Material Transfer
784600
In EPS, If there is a filter selected, there is an Exception pops up when select
Interactive tab. 5) 774368 - In EPS, Filtered as Company name, cannot generate all
reports (fixed in 5000.1.0.1 patch)
787559
Data Migration Tool won't build java classes on a machine where the time zone is +
GMT (fixed in 5000.1.0.1 patch)
787711
Migrating into an R5000.1 EDM Oracle 10G database counts special characters as
more than 1 character when staging (fixed in 5000.1.0.1 patch)
788088
Postmigration Query #111b in Oracle has SQL Server function calls (fixed in
5000.1.0.1 patch)
5000.1.7
Page 97 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
788711
Enhancement - EPS Service -User wants option to print files to directory based on
report date and not system date
790077
EDM Data Receiver File Processing during Network Outages
790401
SQL Server Utility failing to attach database for non-English Windows and returning
an overflow error
791175
Is there anywhere in OpenWells where you can enter information about "prefrac"?
791272
EDM - JDataServices. getUserTightGroupInfo() method NOT work for WinAuthentication.
792714
MD_SITE_USER.user_name needs to be changed to NVARCHAR to store Unicode
characters
792949
Increase the width of CD_WELLBORE.api_suffix to 4 characters
794604
Add command line option to EDM Custom Transfer to hide Success Dialog
794647
When we delete a user through EDM Administration Utility, the token assignments
for that user are not getting deleted in database.
794915
EDM - Audit Trail Not Registering Imports
795957
Increase CD_WELL.well_purpose to 40 char long to support WITSML types
797065
WITSML Survey Import: phase is not populated with 'ACTUAL'
Release 5000.1.1
No additional EDM issues were fixed for the 5000.1.1 release.
Release 5000.1.0
The following EDM issues were fixed for the 5000.1.0 release.
Defect
No.
Description
738209
Users Full name should be shown in list of users.
748640
Need additional units added to Volume and Density Unit Class.
749650
Wrong label in CD_DATUM.well_name.
751815
WITSML Import/Export need support for Barite field.
754455
Group properties update performance is very poor when custom DEF's are used
extensively.
754566
In EDM User Security, Application Tokens Section, the Column Headers for Application
Tokens should not scroll; they should be a fixed row.
5000.1.7
Page 98 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
755612
Wellbore equipment component spreadsheet and properties capturing and displaying
different fields for component Min ID.
759742
Drop CD_ASSEMBLY_COMP.min_id field from 5000.1 onwards.
760984
Weight per Unit in Mud Inventory should be unitless.
761671
Need to include Mudbase Type for WITSML import.
761801
WITSML Fluid import issues (Testing from Shell Group).
762833
A DEX file from the Summit application has fields in the unit lbm. However, the Field
Mapping option in EDM Administration under Stimulation specifies that the unit is ton
(FPS) for these fields which caused the fields to be multiplied by 2 which is incorrect.
765063
CD_GRADE records that have no relevant data to them are affecting the performance
of casing catalogs.
766202
The current association of Grade material and temperature deration in EDM software
requires you to create multiple material pseudo names to handle multiple temperature
deration schedules (for the same grade).
766392
Landed Weight & Weight in Slips fields should be associated to Large Force unit class,
not Force.
768779
Redundant <TOPLEVEL> XML Export/Import Issue around XML Catalogs.
768780
Use only the Grade, Class, Materials, Temp Deration/Lithologies tables that are a part
of the Entity being exported via XML Export.
769205
Import Export Config Dialog title bar is confusing: the title bar says error even after a
successful import or export. Change the title bar to “Status.”
769677
Changes in Grade_Material_Temp Deration dependency.
770922
Clone of 759603-Database upgrade: load CD_ASSEMBLY_COMP.min_id to id_min
instead.
771157
CD_STRAT_UNIT, CD_ZONE & CD_RESERVOIR data in <TOPLEVEL> data set of
EDM Transfer files should be included in the body of the data set being exported.
771454
Need 5000.1 database update wrapper called EDM_5000_1_0_0_DB_Update.exe.
772458
Data Services - Need to create new pipe name: Scab Liner pipe VIT pipe.
772537
Need two new fields in CD_LOCATION_CONGRESS to record quarter/quarter.
772629
Missing 2 lithology types: Avg. Permafrost and Silty Sand.
773489
Add a new field to CD_RIG.
773881
Create all iWellFile Tokens for iWellFile R5000.1 software.
773960
UNIT CLASS = Create a new unit class "Gas Production rate (Large)" unit.
774020
Request Operator and Reporting Time fields in the Event Properties.
5000.1.7
Page 99 of 423
May 2010
Draft
Defect
No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
774021
NPT Title in NPT dialog is a memo, but in Time Summary spreadsheet it is 255 only.
774023
Need 'Formation Gradient' field to support alternate MASICP workflow.
774025
Need to change some default labels in stimulation form.
774026
Gas Concentration (class_id=186).
774028
No place to record Off Bottom Circulating Pressure.
774029
'Actives Stages' should be labelled 'Active Stages'.
774031
Require Communication Y/N and Communication Remarks field in Stages section.
774189
Unit of measure MEASURE_Mft3_d has issues.
774811
User needs creation of 6 new units in EDM (GL/L, L/ SK 100LB, KVA).
775375
Some fields in CD_ASSEMBLY_COMP need to have labels updated.
776307
String Fluids Export should only export relevant data just like Catalogs - In <TOP
LEVEL> as well as in the body.
776716
New location code for US ROCKIES for MD_PK_LOCATION_TYPE_CODE.
777251
DM_EVENT.event_no needs to be increased from 20 characters to 30 characters.
777279
(Clone of 777235) In oracle materials exp. coeff. are incorrect for non-steel materials.
777497
Additional tokens needed for Definitive Survey Locking support.
778798
Table linkage between DM_OPER_EQUIP_FAIL and DM_ACTIVITY is wrong.
779358
Copy/Paste needs to handle COMPASS link tables.
779885
New displayed units for EDM software.
780365
- Support new RPG field in Bit Operations(DM_BIT_OP.rpg - double (rev/volume e.g.
rev/gal).
780791
Need "Sampling Depth Interval" added to the following tables CD_WELLBORE>rt_samp_depth_interval - CLASS_DEPTH.
782048
Change the class_id from Flow Rate (Cement) to Flow Rate (Mud).
5000.1.7
Page 100 of 423
May 2010
Draft
Defect
No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
EDM Known Issues
The following EDM known issues for releases 5000.1.0 through 5000.1.7 are described
below.
Release 5000.1.7
There are no additional EDM known issues for the 5000.1.7 release.
Release 5000.1.6
Draft
There are no additional EDM known issues for the 5000.1.6 release.
Release 5000.1.5
There are no additional EDM known issues for the 5000.1.5 release.
Release 5000.1.4
There are no additional EDM known issues for the 5000.1.4 release.
5000.1.7
Page 101 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.3
The following is a known issue for the 5000.1.3 release.
Defect No.
Description
800234
General: On a 64-bit machine, when you try to configure the data source
as you normally would in a 32-bit environment, the 32-bit ODBC drivers
are not showing as a valid Data Source on the login screens--only 64-bit
drivers are shown. When you launch an application, the Data Source
dropdown does not include the ODBC entries as expected. See screen
shot with both the ODBC window and the login window displayed:
Draft
WORKAROUND: On 64-bit machines, you now go to a different location
than in the past to launch the ODBC Administration dialog:

\Windows\SysWOW64\odbcad32.exe.
EDM currently works only with 32-bit drivers.
5000.1.7
Page 102 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Defect No.
Description
804333
EDM Admin Utility, Picklist Editor, Oracle databases: When you edit a
Picklist and then Save, there is an exception in the log file regarding
“insufficient privileges.”. WORKAROUND:
grant EDMROLE to <user>;
alter user <user> default role ALL;
Example:
grant EDMROLE to EDM;
alter user EDM default role ALL;
Draft
Example:
grant EDMROLE to EDMADMIN;
alter user EDMADMIN default role ALL;
Explanation:
EDMROLE contains the required permissions to update picklist contents.
It must be granted to the database user, and enabled. The two statements
above will do that.
Note: These statements require administrative privileges. To run them,
log in to Oracle as SYSTEM or another sufficiently privileged user. For
security reasons, log out (of Oracle) immediately after.
807180
Database Update: Running a dbUpdate against a SQL Server Express
database having a space in the file name, after the install, the template
table (WP_WORKSPACE) is completely blank. Preexisting templates are
deleted and the updated/new ones are not added. 

WORKAROUND: Workspaces and templates can be loaded from the
EDM Admin utility. DT tables (migration mappings) can be loaded by
running dt_data_tables.sql using 
osql.osql -U sa -P Landmark1 -D EDMDB -n -i dt_data_tables.sql
Release 5000.1.2
There were no additional known issues for the EDM 5000.1.2 release.
Release 5000.1.1
There were no additional known issues for the EDM 5000.1.1 release.
5000.1.7
Page 103 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.0
The following are known issues for the EDM 5000.1.0 release.
Description
762579
On the Field/Office Transfer process, EDM Data Receiver is not working
as expected in it that it does not check the directory AND its
subdirectories for new transfer files but only the root directory.
761665
WITSML import does not import certain mud check data into OpenWells
software such as time of mud check, and mud check depths.
767436
Footage Depths are .01 to .03 different from v2003.16 to Release
5000.1.0.The default US Survey Feet is not correct, its Depth, Distances,
Heights has unit selected to standard feet not US survey feet.
754529
Customizing OpenWells Test data entry form layout may result in fields to
be hidden so that only one sub-sections is left.
761801
WITSML Fluid import may have issues with daily operations report in
EDM software.
754965
Exporting/Importing picklists does not work correctly when numeric fields
are being set to Integer format, and when non values are not being set
regardless of original format.
765990
Catalogue export files contain may data which should not be present in
this type of transfer file.
751252
One Chinese character is handled as two Latin characters in OpenWells
software. 

1. Launch OpenWells software.
2. Go to Lesson Properties > Input 128 Chinese characters in Summary/
Comments and click Apply.

There is an Exception generated in the log file. However, highlight
Summary/Comments in Properties page >Press F7 > Check the field
length is 255. It means 255 Chinese characters should be input normally.
631277
ImportTightGroup system setting description inadequate
635520
Problem formatting BINARY_DATA (attachments) in EDM Data Transfer
File leads to Import Validation Error
699865
Duplicate Company names allowed via import
717189
Rename select MD_SITE entities that store system metadata that
customers are changing
719171
The well reference point has to be added at well level
720091
A second pipe catalog with same Properties as the API Casing/Tubing
catalog does not appear as expected in the Import from Catalog dialog.
5000.1.7
Page 104 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
720297
Uncaught Java Exception when attempting database back-up in
COMPASS software
721230
Creating new folder in WITSML file export dialog does not retain focus
721417
EDM Data Services not deleting BHA Operations and Bit Operations
records when Drillstring deleted
729872
WITSML Wellbore level Import/Export. Fields not getting imported
733293
Can not copy/paste site level
740882
Documentation - Database - dbUpdate - SQL Server - Unable to run
update from Client. The workaround for this problem is as follows: If the
user selects 'Run Manually', the resulting script requires the following
filled in:

- username, password, ODBC data source name, and server name.

If the server name is filled in correctly, these tables will be loaded
correctly.
766372
SQL Server Utility throws Run-time error 75 (Path/file access error) at
launch. Non-Administrator windows users do not have rights to create an
ODBC Data Source. This is a Windows restriction.
777277
If you install full SQL Server 2005 with an instance NOT named
EDM5000, database will fail to attach because it is expecting an instance
named EDM5000. To prevent this error, please create an EDM5000
instance.
784122
EDM Software Installation: EDM Database “Restore” functionality does
not work for edmadmin user, because edmadmin does not have the
proper rights (dbcreator) assigned by default. WORKAROUND: Before
attempting to do an EDM database Restore, either login as Database
Administrator or grant dbcreator rights to the edmadmin user.
EDM Table Extensions are currently implemented to support upcoming ARIES®
software functionality and is restricted to selected ARIES tables only at this time.
To create ARIES table extensions you must be logged in as the schema owner,
EDMADMIN.
5000.1.7
Page 105 of 423
May 2010
Draft
•
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
Other EDM applications will not recognize the extension columns for update or
display.
•
Windows Authentication on Oracle: If you have Oracle Wallet (Used by the
OpenWorks client in conjunction with the EDM to OpenWorks Link utility) installed
on a client, Windows Authentication for Oracle will not work.
Draft
5000.1.7
Page 106 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
EDT™ Software
Enhancements
Fixed Issues
Known Issues
EDT Enhancements and New Functionality (Integration)
The EDT integration enhancements and new integration functionality for releases
5000.1.0 through 5000.1.7 are described below.
Release 5000.1.7
Enhancements and bug fixes were made for OpenWells. Bug fixes were made for
PROFILE. Changes were made to the EDM data model in support of the above
changes.
EDM Administration Utility Enhancements
For 5000.1.7, the following enhancements were made to the EDM Administration
Utility:
•
Well Site Canvases - To support the new OpenWells® Interactive Well Site, a
number of "pre-configured" canvases are shipped with the EDM database.
Administrators can also create their own within the EDM Administration Utility.
Canvases can be assigned to EDM Groups based on Event Type. 

For more information, see “OpenWells Enhancements and New Functionality”
on page 135.
•
Improvements to performance for EDM Publishing Service - Report
generation performance was improved by an average of greater than 85% for
all reports.
•
Improvements to WYSIWYG Layouts - WYSIWYG form layouts can now be
build and configured directly in the EDM Administration Utility’s Layout
Manager. These layouts can be assigned to the OpenWells Classic Data Entry
5000.1.7
Page 107 of 423
May 2010
Draft
The 5000.1.7 release includes all new 5000.1.3 supported platforms, plus enhancements,
fixes, and known issues from the 5000.1.0 and subsequent releases. There were major
usability enhancements to the OpenWells application. Bug fixes were made for PROFILE
software, and changes were made to the EDM data model to support 5000.1.7. EDM
Publishing Service report generation was improved by greater than 85% for all reports.
The EDT installation script was also modified for 5000.1.7.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Forms or to the new Interactive Well Site canvases. A number of WYSIWYG
layouts are shipped:
•
•
Access Online Help from a Server - OpenWells Client installation now
automatically calls the Online help from the Server location.
•
Picklist Security Levels - Administrator can now restrict an EDM Group or
User's ability to edit picklists in the Picklist Editor.
•
Internal Picklist Filter Clause - Administrators can now further filter Internal
picklists using the And Filter Clause field in the Data Dictionary.
•
Internal Picklist Configuration Additions - Users can now edit some areas
of an Internal Picklist.
•
Date Picklist Support - Date fields can now be configured as Data Driven
picklists allowing for more flexibility in defining data entry parameters.
•
New Unit Type Format for Time - A new format has been added to the Unit
Management System and applied to the Small Time units Class. This format
displays time as HH:MM.
•
Caching Output Report Files - Administrators are no longer required to delete
the Output Report cache when an Output Report file has been replaced or
changed. EDM now recognizes changes to the Output Report files and reloads
automatically.
•
Calculate Cement Stage Top/Base MD based on the Pumping Schedule Two new system settings have been added to the EDM Administration Utility
that determines the Top and Base MD of a Cement Stage, based on the Fluids
entered in the Pumping Schedule.
5000.1.7
Page 108 of 423
May 2010
Draft
— WYSIWYG form layouts used in OpenWells Classic are located in the
Daily Operations, Stimulations, Casing and Cementing folders.
— WYSIWYG form layouts used in the Interactive Well Site are found in the
Casing, Cementing, Recordings and Rig Equipment folders.
Bi-directional Data Synchronization - EDM AutoSync Client addresses the
problem of discrepancies in data updates between the Rig and the Regional
Office and determines whose data to keep by way of policies set at the Regional
level. These policies are configurable by EDM Administrators to conform to
company policies. Several policy templates are provided as starting points;
configurations may be saved and imported to apply to new Rig connections.

AutoSync is used in the new OpenWells Interactive Well Site and can be turned
on in Classic OpenWells, using the AutoSync system setting. In addition
AutoSync requires access to a number of security tokens and roles to operate.

For more information refer to the documentation shipped with EDM AutoSync
software.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
— OpenWells.NPT.add,
— OpenWells.NPT.delete,
— OpenWells.NPT.edit,
— OpenWells.NPT.view
— EDM.Explorer.NPT.lock.
New System Settings - A number of new system settings have been added to
the EDM database. For more information see the Shipped Parameters topic.
—
—
—
—
—
—
—
—
—
—
—
—
AutoIncrementSurveyMD
AutoSync
AutoCatalogSelect
CheckRigAssociation
ComponentOrder
DisableFishTubular
DisablePicklistReadonly
FluidProduced
OpenHolePlug
TopBaseSlurryAndTestsCodes
TopBaseSlurryAndTests
WbEquipAutoInsCompStatus
Release 5000.1.6
Enhancements were made for CasingSeat, StressCheck, WELLCAT, and
WELLPLAN. Major enhancements and GUI changes were made for Well Cost. Bug
fixes were also made for these applications, and bug fixes only were made for
COMPASS.
Well Explorer Enhancements
For 5000.1.6, Well Explorer has been enhanced to support Workspaces for
CasingSeat, StressCheck, and WELLCAT; these Workspaces operate exactly as
they have always done in WELLPLAN in the past.
5000.1.7
Page 109 of 423
May 2010
Draft
•
— TopBaseSlurryAndTestsCodes
— TopBaseSlurryAndTests
Non Productive Time (NPT) Administration Tokens - New tokens have been
added to the EDM Administration Utility to allow administrators to restrict a
user's rights to add, edit, view, delete and lock NPT data. The tokens are:
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.5
Report Manager Enhancements
For 5000.1.5, Report Manager has been optimized to greatly reduce the time and
memory consumption needed to generate reports. Of all EDT applications that use
the EDM Report Manager, OpenWells software benefits the most from the
performance improvements.
Stability—Because EDM Report Manager is solely responsible for any Crystal
Reports related operation, no EDT application crashes related to reports will occur.
If the EDM Report Manager crashes, the hosting EDT application will launch it
again for next report generation.
Performance—In general, there is a minimum of 1 – 2 seconds or 10 – 20%
performance improvement (if cache is present) due to the simplified interface
redesign between the EDM Report Manager and the calling EDT application.
OpenWells software can achieve a greater performance improvement with
additional optimization.
Cache Issues—Individual Report Cache files are now shipped with the EDT
installation and loaded into EDM database. This greatly reduces the time to
generate the first report of any type if the cache is deleted from user’s local folder.
The time saved with this change is between 10 seconds to more than 1 minute.
3rd party reports benefit from this change when they manually generate each
report once from any user’s workstation, and then import all files into each EDM
database with the site import feature.
Benefits to OpenWells Software
For a single report, two additional optimizations now exist in the OpenWells
application: ‘PreLoad’ and ‘PreQuery’.
5000.1.7
Page 110 of 423
May 2010
Draft
General Benefits
Memory consumption—In previous versions, EDT applications load the Crystal
Reports engine into memory when invoking the first report. This memory (about
50MB) is not released until you close the EDT application. In EDT 5000.1.5, the
EDM Report Manager is solely responsible for all Crystal Reports operations
related to report generation, thus freeing 50 MB of memory from any hosting EDT
application.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
It was observed in the past that the first report of any type typically took more time
than the 
second report, even from a different well. The two causes for this delay were that
the database needs to compile the queries for the specific type reports (PreQuery),
and the EDM Report Manager needs to load the Crystal Reports file into memory
(PreLoad).
PreQuery and PreLoad settings are configured from the Report tab on the “Report
Setup” dialog in OpenWells software, which is accessed from the Tools menu >
Report Setup command. On the Report tab, each report can be configured
independently as seen below.
Draft
5000.1.7
Page 111 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
PreQuery and
PreLoad
individual
report options
Draft
Because of the specific nature of each report, not all reports will see an observable
reduction in time if the PreQuery or PreLoad options are applied. Landmark
includes a configuration of PreQuery and PreLoad options, which apply settings
that maximize optimization of reports that benefit most from the features.
Optimize only the reports you need
If you select all reports to Pre Load and Pre Query, expect a 1-2 minute
wait after launch before you preview any reports. Therefore only enable
those reports you frequently use.
5000.1.7
Page 112 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
In order to apply any changes made to the PreQuery or PreLoad options, you must
restart the OpenWells application.
PROFILE software takes advantage of the PreQuery and PreLoad options, but
uses the 
configuration settings applied in OpenWells software.
In addition to the PreQuery and PreLoad optimizations for individual reports
mentioned above, OpenWells software’s batch options also benefit when sorting
reports by type. The batch Export to PDF and batch Print features now balance
performance and memory consumption by restarting the EDM Report Manager
after every 10 reports.
Beginning with EDT 5000.1.5, the OpenWells application will restart the EDM
Report Manager automatically for every 10 reports during a batch printing and
batch export job and release the memory. Thus, when EDM Report Manager
restarts it will preload the reports you previously selected again and there should
not be any memory issues related to batch printing and batch export.
5000.1.7
Page 113 of 423
May 2010
Draft
The Preloading option significantly improves OpenWells software’s performance.
However, this may result in excessive memory consumption by EDM Report
Manager. Memory consumption greatly increases when you either manually
preview or batch preview a lot of reports (for example, 20 reports) without closing
the report window. If the report window is closed after a batch preview, the EDM
Report Manager will automatically restart to release the consumed memory.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
OpenWells software allows you to configure each type of report to display specific
sections with the Tools menu > Report Setup command. Once the view options are
set, reports will print with the same sections all the time. PROFILE uses the options
configured in OpenWells software.
Click this button to view
individual report options
Draft
Benefits to Other EDT Software Applications
— WELLPLAN reports that used to crash the WELLPLAN application when invoked
for the first time after installation no longer cause a crash.
— Over 100 known issues in EDM Publishing Service were re-verified and any failing
verification were fixed.
5000.1.7
Page 114 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
— All EDM Publishing Service 5000.1.2.x fixes were included in EDT 5000.1.5.
— iWellFile 5000.1.5 Report invocation logic/architecture has also changed to support
the new EDM Report Manager.
— If using Adobe Writer Pro 9 to print a report in English text, the Table of Contents
will print on the first page rather than on the last page. Due to limitations with
Adobe Reader, the TOC will continue to print on the last page.
General Integration Enhancements
For 5000.1.5, various integration improvements were made for this release. These
features include:
COMPASS, OpenWells, PROFILE, Well Cost, and WELLPLAN applications
have added enhancements, including the new version of Report Manager
which reduces memory consumption, increases report generation speed, and
adds other improvements (described above).
•
Bug fixes were made for most applications.
•
Changes were made to the EDM data model in support of the above changes.
EDM Administration Utility Enhancements
For 5000.1.5, the following enhancements were made to the EDM Administration
Utility:
•
Catalog Editor System Settings - Two new Catalog Editor system settings—
GenerateAssemblyItemDesc and AlternateCCNConfig—can now be added to
the EDM database. Used together these system settings allow administrators
to define whether the component’s item description is populated by the
concatenated catalog data or with the description only. To only use the item
description, both system settings must be added to the EDM Administration
Utility and configured as follows:
— GenerateAssemblyItemDesc must be set to NO
— AlternateCCNConfig must be set to YES
•
Approval Process Tokens - New tokens have been added to the EDM
Administration Utility to support the new OpenWells and PROFILE Approval
feature. EDM.Explorer.approve, EDM.Explorer.Well.prepare,
EDM.Explorer.Event.prepare, EDM.Explorer.Report.prepare and
EDM.Explorer.Well.viewapprovalhistory.
•
Approval Point Stamp Location - The location of the Approval Point PDF
stamps in the OpenWells and PROFILE applications can be configured using a
system setting.
5000.1.7
Page 115 of 423
May 2010
Draft
•
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
PROFILE Schematic Tokens - Three new PROFILE system settings can now
be added to the EDM database.
— Dual Centered Components - assign specific components to always
draw centered on dual completions.
— Low Priority Components - assign lower priority to certain components
drawn in a schematic that can be smaller than others to make more room
for the more important symbols.
— Use 2D Symbol Scaling - render the 2D packer symbols, expand the
casing so it doesn’t need to bend the dual completions and also use a
few other options only normally needed by the 2D symbol set. 
AutoSync Well Assignment - OpenWells users are now able to assign Wells
to an AutoSync Client for bi-directional updates between Rig and Regional
EDM databases. New tokens have been added to support AutoSync and it's
integration with OpenWells software. AutoSync.AssignWell,
AutoSync.Requestwell, AutoSync.remoteConnect and AutoSync.start.
Release 5000.1.4
•
COMPASS enhancements and bug fixes were made.
•
OpenWells enhancements and bug fixes were made.
•
Changes were made to the EDM data model in support of the above changes.
Release 5000.1.3
•
New platforms are supported.
•
Mobile Checkout licensing feature libraries were added.
Release 5000.1.2
For 5000.1.2 there are no integration enhancements to the EDT software.
Release 5000.1.1
WELLCAT was added to the EDT suite of applications for the first time in the 5000.1.1
release. Also, some Common Well Explorer enhancements were made. This update
release improves the import/export and sharing of Grades, Pipes/Connections
5000.1.7
Page 116 of 423
May 2010
Draft
•
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
between StressCheck and WELLCAT, improves the integration between StressCheck
and WELLCAT, and repairs critical defects affecting key StressCheck and WELLCAT
application functions.
•
Casings/Tubing Catalog—Added Critical Dimensions (Collapse, Axial, Triaxial
Longitudinal and Triaxial Hoop) to the Casings/Tubings Catalog.
•
Grades spreadsheet—Added Cost Factor
•
Materials spreadsheet—Added Thermal Conductivity and Specific Heat
Capacity.
•
Catalogs—Catalogs were added for Well Completion components, and support
for these catalogs was added to OpenWells, PROFILE, WELLPLAN, and
Catalog Editor.
Release 5000.1.0
The 5000.1.0 release of Engineer’s Desktop supports the Microsoft Vista operating
system, has new LAM (FLEXnet Publisher) licensing and contains some critical bug
fixes. Well Cost was added to the EDT suite of applications for the first time in this
release.
In addition to EDM database changes, a number of workflow improvements and
usability enhancements were made to the Drilling & Completions applications to
provide for consistent data management and user interaction with these products.
More complete enhancement descriptions for each of the Engineer’s Desktop
applications are provided in their respective sections. This section will detail new EDT
software functionality and user interface components shared between the Drilling
applications.
Enhancements for EDT release 5000.1 include the following:
5000.1.7
Page 117 of 423
May 2010
Draft
Well Explorer Enhancements
• Tubular Properties Changes—Temperature Deration, Anistropic Radial Yield,
and Anistropic Hoop Yield moved from Material Properties to Grade Properties.
Also, XML import/exports enhanced to not carryover unnecessary tubular
properties that are not used by corresponding assemblies. This simplifies the
process of copying tubular grades, pipes, and connections between the EDM
database and StressCheck or WELLCAT software inventories.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
EDT 5000.1.0 Common Well Explorer Enhancements
Located by default on the left side of the application window, the Well Explorer
functions much like the Microsoft® Windows Explorer. Specifically, it is organized
as a hierarchical data tree, and you can browse the EDM database at seven
descending levels, though this varies between applications.
For 5000.1.0, the following new features were added to Well Explorer:
•
Location Information—Added a ‘Location’ tab to Site and Well Properties
dialogs. This tab displays any location information that was added in the
COMPASS application.
Draft
Location tab added to Well
Properties Dialog (read
only in all applications
except the WELLPLAN
application)
Location Uncertainty and
Azimuth Reference added
to Site Properties Dialog
5000.1.7
Page 118 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
Tubular Properties Changes—Anisotropic Radial, Hoop Yields, and
Temperature Deration have been moved from Material Properties to Grade
Properties. Also, XML imports/exports have been modified so that they don’t
carry unnecessary tubular properties that are not used by the corresponding
assemblies.
•
Implementation in Real-Time View: The Well Explorer implementation in
Real-Time View software exposes logs, and any associated curves, from the
Wellbore level.
Filter
Draft
shows currently
selected filter
(notice “funnel”
indicating a filter is
applied to this node)
Hierarchical
“Tree”
Virtual Folder
Currently selected
data item (a Well, in
this example)
Log
Log Curves
Associated Data Viewer
Components “associated
with” the selected data
item (the Well, in this
example). Double-clicking
on Lesson Learned, or
Attachments opens the
respective editor on
demand.
A file or folder
linked to the
selected Well
as an
“attachment”
Figure 1: Well Explorer, shown in the Real-Time View application
•
5000.1.7
Well Explorer was added to Real-Time View with the following special
features:
Page 119 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
— New icons added for log (
) and log curves (
). Logs can now be
opened by double-clicking on the Log icon in the Well Explorer.
— Also, logs can now be opened from a right-click menu command on the
Log icon in the Well Explorer.
— Drag and Drop individual log curves onto the log viewing area
— ASCII, LAS (Time), and LAS (Depth) log import from the Wellbore level
right-click menu. The functions are now accessed via context menu
commands from the Well Explorer.
— Logs can be opened, imported, renamed, and deleted from the Well
Explorer
•
License Expiration—Users will now be warned when their product license is
about to expire. This option is configured through the LAM Environment
variable.
.
License expiration information
shown in the Help > About
dialog.
Figure 2: License Expiration
•
5000.1.7
Password Expiration—Password Expiry option now available for EDM users,
configured through the EDM Administration Utility. EDM Administrators have
the option to set an expiration on user passwords. This option is configured in
the EDM Administration Utility. Starting 14 days prior to the password expiry,
the user receives the following message each time they log in, and can change
the password or defer the notification an additional day.
Page 120 of 423
May 2010
Draft
General Integration Enhancements
For 5000.1, various integration improvements were made for this release. These
features include:
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Figure 3: Password Expiration Notice
“Mobile Checkout” licensing—This new feature allows users to check out a
license from the license server before disconnecting from the network.
Licenses can be borrowed for a specific period, after which the license is no
longer valid on the offline computer and is made available again on the license
server.
•
Definitive Survey Locking—The Definitive Survey is the composite survey for
a wellbore from surface to bottom hole (TD). It is used as the reference survey
in anti-collision calculations, which are regarded as safety critical in well
operations. The Definitive Survey is shared across several applications
(OpenWells, PROFILE, StressCheck, WELLPLAN) but can only be edited in
the COMPASS application, which is the main application for managing
directional survey information. To improve security of the definitive survey, a
two-pronged approach has been taken: (1) Token-based locking mechanism,
and (2) Definitive Survey locking mechanism.

The Token-Based Lock mechanism is an alternative to the password protected
method of managing and using the ‘Lock’ checkboxes in the Well / Contractor
Explorer property dialogs. This new mechanism makes it possible to define who
can lock any particular item within the Well / Contractor explorer hierarchy on a
per group and/or user basis.
— The Token-Based Lock mechanism is enabled by setting the
‘UseLockSecurityTokens’ system setting to ‘TRUE’.
— To support this new method ‘lock’ tokens have been added to EDM for
each property dialog. If a group or user is granted the ‘lock’ token for a
property dialog they will have the ability to lock the information within that
dialog. If the token is revoked the lock field for that property dialog will be
disabled for that user or group.
The Token-Based Lock mechanism operates independently of any ‘Locked
Data’ passwords set at the Company level. Users will not be prompted with
warning or password dialogs when enabling or disabling a locked field. 

The Definitive Survey Lock field is a new checkbox added to the Survey
Program tab in the Actual Design properties dialog. Enabling the Definitive
Survey Lock performs the following actions:
5000.1.7
Page 121 of 423
May 2010
Draft
•
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
— The Survey Program for the Actual Design is locked
— The Vertical Section for the Actual Design is locked
— Any Survey that contributes to the Survey Program is locked. This
includes surveys in parent wellbore designs that contribute to the
sidetrack definitive path defined by the locked survey program.
The Definitive Survey Lock field is only available within the COMPASS Actual
Design properties dialog. If the Definitive Survey Lock has been set in the
COMPASS application, the OpenWells application will treat the affected survey
data as read only.
Upgraded WITSML support—Ability to import/export WITSML 1.2.0 and 1.3.1
objects supported by the OpenWire application. (For the file based WITSML
1.2.0 and 1.3.1 Import/Export, only five objects are supported: Well, Wellbore,
Trajectory, Fluids, Target. OpenWire software supports many more. The
attribute mapping has greater coverage for 1.3.1. Well, Wellbore, and
Trajectory can be imported and exported through the COMPASS and
OpenWells applications. Fluids can only be imported and exported through the
OpenWells application. Targets can only be imported and exported through the
COMPASS application.)
•
Geodetic Information transfer—Geodetic information is now exported in
transfer files.
EDM Administration Utility Enhancements
For 5000.1, the following enhancements were made to the EDM Administration
Utility:
•
Survey Locking —Configuration to support Definitive Survey Locking was
added.
•
Password Expiration—Administrator can set expiration on user password,
forcing the user to change their passwords at regular intervals.
•
Enhanced User Management—Added EDM Security > Users node > Sort
Users right-click menu command to the EDM Administration Utility. EDM
Administrators can now sort users by User Name or Full Name.
•
Security Tokens—these were added to support Sub-Assemblies in the
PROFILE application.
•
New System Setting—NPD_CDRS_LOG_TEMPTYPE has been added to
support CDRS Report Generation (for the OpenWells application).
•
Rig Type Images—Administrators can assign the four available OpenWells
Rig Equipment Editor images to any Rig Type Code (for the OpenWells
application).
5000.1.7
Page 122 of 423
May 2010
Draft
•
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
Shakers in WYSIWYG—Shaker Operations have been added to the
WYSIWYG layout (for the OpenWells application).
•
Custom WYSIWYG—Administrators can add custom WYSIWYG forms that
can be assigned to OpenWells report layouts.
Draft
5000.1.7
Page 123 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
EDT Fixed Issues (Integration)
The EDT integration issues fixed for releases 5000.1.0 through 5000.1.7 are described
below.
Release 5000.1.7
The following issue was fixed for the 5000.1.7 release of EDT software.
Description
828886
Remove any parameters that are no longer valid logging items for SAM.
830469
EDT 5000.1.5.x and higher upgrade unpacks Historian files to Temp folder
irrespective of whether user wants to install Historian or not.
Draft
Defect No.
Release 5000.1.6
The following issue was fixed for the 5000.1.6 release of EDT software.
Defect No.
Description
826558
EDM AutoSync has problems with text data that contains ASCII control codes.
Release 5000.1.5
The following issues were fixed for the 5000.1.5 release of EDT software.
Defect No.
Description
813355
Well Explorer: Drilling applications should search filter file (*.qry) from the default
shared folder (\Documents and Settings\All Users\Application
Data\Landmark\OpenWells\Queries\Drilling).
814584
EDM Publisher: EDM Publisher will not generate reports or send emails if the
service is running on Windows 2003 Server.
Release 5000.1.4
There were no integration issues fixed in the 5000.1.4 release.
5000.1.7
Page 124 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.3
Defect
Subject
Product
Version
Reported
Comp
Level 1
Comp
Level 2
786220
Fails to install SQL Server
Express 2005 successfully for
64-bit operating system. This
has been fixed in 5000.1.3.
EDT
5000.1.0
EDM
Installation
Release 5000.1.2
Defect
Subject
Product
Version
Reported
Comp
Level 1
633125
BHA Summary Report
performance improved by
producing exact Schematic plots
EDT
2003.14.0.
0
Reporting
Engine
786220
Install: Update the EDT
installation to handle 64-bit OS.
Fixed for the 64-bit versions of
Windows Vista and XP in the
5000.1.3 update release.
EDT
5000.1.0
Install
788983
Need to reduce Report Manager
memory footprint
EDT
5000.1.0
Reporting
Engine
796814
OpenWells reports are read only
when actual design is open in
PROFILE
EDT
2003.16.1.
17
Integration
Requiremen
ts
796814
OpenWells reports are read only
when actual design is open in
PROFILE
EDT
2003.16.1.
17
Integration
Requiremen
ts
797041
Add the ability to place a
{today’s} date in the Reports
config file
EDT
5000.1.0.0
02
Reporting
Engine
797044
Ability to store "partner" email list
in the xml config
EDT
5000.1.0.0
02
Reporting
Engine
797702
Request for EDT R5000 that all
the Application login screens
display only ODBC Data Source
Names that are using the ODBC
Driver: SQL Native Client.
EDT
5000.1.0
General
5000.1.7
Page 125 of 423
Comp
Level 2
Data
Generation
May 2010
Draft
The following EDT integration issues were either addressed or have workarounds for
the 5000.1.2 release.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Defect
Subject
Product
Version
Reported
Comp
Level 1
798156
Request for EDT R5000 and
above versions that all C/C++
Application login screens display
only ODBC Data Source Names
that are using the ODBC Driver:
SQL Native Client.
EDT
5000.1.0
General
799430
SQL Server Utility - No longer
launches after installing the
Windows Update Hotfix 3073 for
MS SQL Server 2005 SP2.
EDT
5000.1.0
General
Comp
Level 2
Draft
Release 5000.1.1
No EDT integration fixes were done for the 5000.1.1 release.
Release 5000.1.0
Defect No.
Description
161642
Integration: SAM indicator stays green after the SAM service has stopped.
(Fixed)
634540
Reporting Engine: Report Manager not staying active for reports run in
PROFILE. (Fixed)
701247
Runtime: A number of picklists get deleted from the database after a
migration. (Fixed)
702735
Well Explorer: Hazards selection interface in Well Properties implemented
inconsistently. (Fixed)
703081
Data Services: WELLPLAN software crashes on deleting (in OpenWells
software) an Instant Case created in WELLPLAN software. (Fixed)
703379
Reporting Engine: Web/scroll wheel doesn’t work when previewing the
COMPASS reports. (Fixed)
715048
Data Services: COMPASS software crashes when you do a backup at the
default location. (Fixed)
719181
Data Services: Daily Operations Data Entry forms Arrive/Depart Checklist
data not visible after Wellbore level export. (Fixed)
721451
Data Model: Manual run of database update (Oracle) throws missing or
invalid option error. (Fixed)
721543
Data Model: MEASURE_GAL_HR unit is incorrect on database update.
(Fixed)
5000.1.7
Page 126 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
722852
Data Model: Coring report fields DM_CORE.interval_base and
DM_CORE.interval_top need to be flagged as depth datum affected.
(Fixed)
725895
Data Services: Copying wellpath from another design creates duplicate 0
depths. (Fixed)
723612
Data Synchronization: OpenWells and Field/Office Data Transfer track
Report Transfer status differently. (Fixed)
726576
Citrix: Error generated in Citrix environment when migrating data
(COMPASS For Windows software import). Workaround: Assign read/
write rights to the data transfer properties file on the Citrix server. (Fixed)
727011
Reporting Engine: After a few reports are open in Report Manager,
additional reports fail with “out of memory” issues.
727988
Citrix: Citrix Virtual Memory Optimization incompatible with some
applications; applications fail to launch; the logon dialog box does not
appear. This is a known issue with Citrix MetaFrame Presentation
Manager 4’s new “Virtual Memory Optimization” feature. Workaround:
Either turn off the Virtual Memory Optimization feature, and re-install the
applications. Applications will now launch properly. Alternatively, a list of
specific DLLs and executables can be disabled without requiring Virtual
Memory Optimization to be turned off (refer to the EDT Citrix Guide). Citrix
may address this issue in future releases. (Fixed)
728606
Localization: For Chinese localization, OpenWells software hangs while
changing language in status bar when OpenWells Well Explorer dialog is
open. Workaround: Add the following environment variable—
EnableMultiLanguage (MUST be set to the value 'true')—to allow multilanguage input system, such as Chinese, to work correctly with
OpenWells software. Other Drilling applications that re-use parts of
OpenWells software (Lessons Learned and Find dialogs, for example) will
also need this environment variable. (Fixed)
728802
All applications: System filters for the new “Find” feature in the Well
Explorer tree are only available for the installed user. Other users (for
example, Citrix or client-server users who did not install the software using
their userid) will have to copy the system filter *.query files to their local
user directory. The local user directory is where the applications look for
the *.query files used for by the Find feature. These *.query files can be
copied from the following location (which is the local user directory of the
person who installed the software):

C:\Documents and Settings\
<InstallUserID)\ApplicationData\Landmark\OpenWells\Queries\Drilling.
(Fixed)
729229
Runtime: Data Migration Tool shuts down automatically during postmigration process (Oracle only). No errors. (Fixed)
5000.1.7
Page 127 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
729949
Runtime: For the 2003.14.1.0 to 2003.16 Oracle 9i upgrade, EDM system
settings - Project Data Locking setting information is lost. (Fixed)
730051
Field/Office Data Synchronization: Custom configuration import doesn’t
create picklists. (Fixed)
733747
Reporting Engine: Report Manager should filter fields used in .rpt file.
(Fixed)
737110
Admin Utility: When importing Site Configuration files, the Date is invalid.
(Fixed)
775560
Installation: “Error 1718: File <filename> was rejected by signature
policy.” This Windows 2003 Server issue occurs when the Windows
Installer has insufficient memory allocated and therefore cannot verify that
the *.msi or *.msp package contains a valid digital signature.
WORKAROUND: Install Microsoft hotfix KB925336 at http://
support.microsoft.com/kb/925336.
781431
A SQL Server/MSDE/SQL Server Express Database Name cannot have
a dot (.) in it. If your EDM Database Name has a dot (.) in it, the Database
Upgrade will not work properly. (For example, the Database Name
‘EDMDB’ will work, ‘EDM.DB’ will not). This does not affect your database
Description (for example, ‘EDM 2003.21’)
5000.1.7
Page 128 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
EDT Known Issues (Integration-related)
The Engineer’s Desktop software release has been a significant development effort
intended to realize the primary strategy of supplying integrated applications to the client
that enable engineering workflows. For each product, changing the application to support
a new data model was a significant challenge.
Release 5000.1.7
There are no additional EDT integration-related known issues for the 5000.1.7
release.
Release 5000.1.6
The following EDT integration known issue was reported for the 5000.1.6 release.
Defect No.
Description
831966
Uncaught Java Exception (Java heap space) error on applying
'COMPASS Designs' filter to a large data set in Well Explorer
Release 5000.1.5
There are no additional EDT integration-related known issues for the 5000.1.5
release.
Release 5000.1.4
There are no additional EDT integration-related known issues for the 5000.1.4
release.
5000.1.7
Page 129 of 423
May 2010
Draft
Engineer’s Desktop software is being released with some outstanding issues that are
known, but not thought to prevent users from achieving the efficiency gains provided by
these applications. The following list of issues enables clients to compare observed
application behavior against issues known to us at the time of release. These issues will
be addressed in future releases of EDT software together with any additional issues
reported by clients.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.3
The following EDT integration known issues were reported for the 5000.1.3 release.
Defect No.
Description
800234
General: On a 64-bit machine, when you try to configure the data source
as you normally would in a 32-bit environment, the 32-bit ODBC drivers
are not showing as a valid Data Source on the login screens--only 64-bit
drivers are shown. When you launch an application, the Data Source
dropdown does not include the ODBC entries as expected. See screen
shot with both the ODBC window and the login window displayed:
Draft
WORKAROUND: On 64-bit machines, you now go to a different location
than in the past to launch the ODBC Administration dialog:

\Windows\SysWOW64\odbcad32.exe.
EDM currently works only with 32-bit drivers.
804750
EDT 5000.1.3 does not support COMPASS Live Link on Vista 32-bit or
64-bit (because OpenWorks is not officially supported in these
environments).
804781
Install: With SQL Server installed (not SQL Server 2005 Express) with the
EDT required EDM5000 Named Instance, when the user runs the EDT
5000.1.3 install, an error is thrown with:
“An instance with the same name is already installed on this computer. To
proceed with SQL Server Setup, provide a unique instance name.”
SQL Server Express install then fails and is not installed.
5000.1.7
Page 130 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Defect No.
Description
804878
Install: On 64-bit systems, during SQL Server Express 2005 install, error
message is thrown citing “known compatibility issue”.
Draft
SQL Server Express 2005 will install correctly if you click Run Program button.
804913
VISTA 64 / W2K8 SERVER 64 -Inform user how to launch the correct
version of the ODBC administrator for creating 32-bit DSNs. EDT
applications require 32-bit DSNs. On 64-bit OS's such as Vista and
Windows 2008 server, the ODBC Administrator launched by default is the
64-bit version. In addition, the ODBC administrator exe
(ODBCAD32.EXE) is called the same name for both the 32 and 64 bit
versions.
When adding 32-bit DSNs on 64-bit OS's such as Vista and Windows
2008 Server, user should not use the Control Panel->Administrative
Tools->Data Sources (ODBC) and instead browse for and launch the
ODBCAD32.EXE from their WINDOWS\SYSWOW64 folder.
805460
Citrix XenApp: Drilling Data Migration hangs upon login with a “Using
default log file” message. Pressing OK on the message does not clear it,
so the utility is effectively hung and must be killed. WORKAROUND: Use
a non-Citrix environment, or be the Administrator.
805461
Citrix XenApp: Drilling Data Migration hangs upon exit with a “Using
default log file” message. Pressing OK on the message does not clear it,
so the utility is effectively hung and must be killed. WORKAROUND: Use
a non-Citrix environment, or be the Administrator.
805467
Citrix XenApp: EDM Publishing issues a “file privileges” error upon exit.
This happens when logged in as a non-Administrator user. Pressing OK
on the message does not clear it, so the utility is effectively hung and must
be killed. WORKAROUND: Use a non-Citrix environment, or be the
Administrator.
5000.1.7
Page 131 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Defect No.
Description
806236
Install: With SQL Server 2008 installed (not SQL Server 2005 Express) on
user’s machine: during the install and afterwards, when you try to launch
SSUTILS (SQL Server Utility) from the Start Menu, an error is thrown with:
“SSUtils
Must abort due to SQL Server version issues.
This may be expected in this environment.
Environment is
Windows 2008 Server - 64 Bit
SQL Server 2008 - 64 Bit installed”
SQL Server Utility is not compatible with SQL Server 2008.
806348
5000.1.7
Install: Vista systems: On Vista systems, running with User Access
Control on, a standard user is not able to run SQL Server Utility (SSUtils).
Running SSUtils prompts the user for an Administrator login (username/
password). A standard user is unable to run SSUtils without an Admin
login with UAC enabled.
Page 132 of 423
May 2010
Draft
With SQL Server already installed, the 5000.1.3 install detects it and skips
installing SQL Server Express. When you try to launch SQL Server Utility,
the utility tries to launch with SQL Server 2008 and that fails with this
error:
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.2
No additional EDT integration known issues were reported for the 5000.1.2 release.
Release 5000.1.1
No additional EDT integration known issues were reported for the 5000.1.1 release.
Release 5000.1
Defect No.
Description
724913
Data Services: Some Data Services operations fail with long user names.
725544
Installation: None of the EDM/Drilling and Completions applications
launch if installation folder contains Russian, Chinese character set.
726641
Installation: Uninstalling Drilling will prevent EDM Publishing Service from
launching.
728737
Installation: Regarding 2003.14.1.0 to 2003.16 peaceful co-existence,
2003.16 installation renders 2003.14.1.0 COMPASS Report Manager
non-functional after uninstalling 2003.16.
729311
Installation: Real-Time View and Field/Office Data Transfer are not
removed when the single application install they are identified with is
removed.
729667
Data Services: Long datum names causes Wellbore Copy/Paste to fail
with error.
730135
Well Explorer: When working in the Well Explorer between applications
(for example, WELLPLAN and StressCheck), each application does not
recognize the others’ changes in the Change History until the tree is
refreshed. Workaround: refresh the tree before looking at Change History
properties.
730283
Targets are not imported when a plan is imported over an existing plan.
761495
Catalogs imported with custom tubular properties will display INVALID in
the custom tubular properties field.
765781
Data Migration: The second application that is migrating data from R2000
within the same session of the Data Migration Utility fails, throwing
multiple errors. WORKAROUND: If the customer wants to migrate data
from more than one legacy application, they must close the Data
Migration Utility in between migrations.
5000.1.7
Page 133 of 423
May 2010
Draft
The following EDT integration known issues were reported for the 5000.1.0 release.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
775560
On Windows 2003 Server (specifically systems running Citrix; not known
if Citrix is related or not), an error is thrown during the install with: 

Landmark Engineer's Desktop 5000.1 (EDM) Installer I...
Error 1718.File C:\WINDOWS\Installer\2a9142e.msi was rejected by
digital signature policy

WORKAROUND: see the EDT Drilling Installation Guide’s
Troubleshooting section. The workaround includes creation of a local
Security policy to allow for these bad digital signatures
777277
If you install full SQL Server 2005 with an instance NOT named
EDM5000, database will fail to attach because it is expecting an instance
named EDM5000. To prevent this error, please create an EDM5000
instance.
781795
Windows Vista Only—Integration issue: The connection to the SQL
database via the OpenWire Server panel in the Admin Utility fails.
WORKAROUND: Do not run OpenWire software through the links in the
COMPASS or WELLPLAN applications.
785258
Windows Authentication on Oracle: If you have Oracle Wallet (Used by
the OpenWorks client in conjunction with the EDM to OpenWorks Link
utility) installed on a client, Windows Authentication for Oracle will not
work.
786220
Install: EDM - Update the EDT installation to handle 64-bit OS when
installing SQL Server Express 2005.
5000.1.7
Page 134 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
OpenWells® Software
Enhancements
Fixed Issues
Known Issues
The 5000.1.7 release includes support for all 5000.1.3 supported platforms, plus fixes
from the 2003.16.1.26, 2003.16.1.27 and 5000.1.5.2 patches, as well as, enhancements,
fixes and known issues from the 5000.1.0 through 5000.1.6 releases. Major usability
enhancements and bug fixes have also been made to OpenWells for the 5000.1.7
release.
Draft
OpenWells Enhancements and New Functionality
The OpenWells enhancements and new functionality for releases 5000.1.0 through
5000.1.7 are described below.
Release 5000.1.7
The Interactive Well Site
The OpenWells application can now be launched to an interactive data entry area
called the Interactive Well Site. This new view of OpenWells has been designed to
enhance and simplify data entry at the Rig site.
The Interactive Well Site simplifies data entry for users at the Rig Site by providing
intuitive data entry that is consistent with real-world activity at a well, lending itself
to both trained and untrained staff. Users no longer need to understand the
OpenWells Well Explorer tree as they can now access data entry areas in one or
two clicks.
The Interactive Well Site:
•
reduces data entry time and duplication
•
applies “surface canvases” based on whether the rig is a land rig or an offshore
rig and for offshore rigs the Rig Type
•
subsurface canvases are based on the Canvas assigned to Event Types
•
creates Classic Reports in the background so users do not have to concern
themselves with the Well Explorer tree
•
provides direct access to Well, Wellbore, Event and Rig properties
5000.1.7
Page 135 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
clearly displays the current Day's start and end time as defined by the Reporting
Standard
•
uses WYSIWYG (What You See Is What You Get) and Classic Data Entry
forms
•
WYSIWYG forms are now customizable in the EDM Administration Utility
•
contains visual indicators for where data has been entered and what data entry
is completed on a given day
•
provides users with easily accessible buttons to begin (
Operations
•
supports schematics, data validation, batch output report printing and XML data
import
) or end (
)
5000.1.7
Page 136 of 423
May 2010
Draft
Figure 4: The Interactive Well Site showing an Offshore Rig
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Canvases
The Interactive Well Site presents OpenWells data on a graphical interface called
a Canvas. Each Canvas is made up of a surface image, a subsurface image and
a number of links to data entry areas, such as Properties dialogs, WYSIWYG forms
and Classic Data Entry forms.
A number of “pre-configured” canvases are shipped with the EDM database.
Administrators can also create their own in the EDM Administration Utility.
Canvases are assigned to EDM Groups based on Event Type.
Land Rig
Jackup Rig
Semi-Submersible Rig
Drillship Rig
Figure 5: Interactive Well Site Canvases
•
The Land image appears if the Well's Datum is set to Land (i.e., the Offshore
checkbox is not selected in the Well Properties Depth Reference tab).
•
The Semi-submersible image appears if the Well's Datum is set to Offshore.
•
The Drillship image appears on offshore wells if the Rig Type (in the Rig
Properties) selected is Drillship.
•
The Jackup image appears on offshore wells if the Rig Type selected is Jackup.
5000.1.7
Page 137 of 423
May 2010
Draft
The Interactive Well Site uses one of four surface images to represent a well site:
Land, Semi-submersible, Jackup and Drillship.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
From the Rig picture the user can select the subsurface image, in the bottom left
corner, to transition downhole to the wellbore.
Draft
Click to transition
downhole
Figure 6: Transition downhole
One of the three subsurface wellbore images appear based on the canvas
configuration and EDM Group assignment to the Event Type.
Drilling Subsurface
Completions Subsurface
Workover Subsurface
Figure 7: Interactive Well Site Downhole canvases
5000.1.7
Page 138 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Toolbar
The tool bar running down the left side of the Interactive Well Site
provides users with easy access to navigation, as well as, quick
access to a number of OpenWells features.
Select Date Button - Quickly navigate to a specified reporting
day. This button also displays the currently selected date
•
Select Well Button - Search for and select a Well
•
Wellbore/Event Button - Select the Wellbore and Event
•
Start and Finish Buttons - Begin or End Operations
•
Wellbore Schematic Button - Display the Wellbore
Schematic
•
Print Reports Button - Print one or more Output Reports
•
AFE and Plan Buttons - Open the Cost Estimate and AFE or
Well Planning reports
•
Refresh Button - Get any recent changes made to the
EDM™ database
•
Data Validation Button - Validate data by runing a set of
rules against it
•
Import Button - Import data from an EDM data transfer file
(edm.XML, rig.XML or .XML).
•
Options Button - configure the mode OpenWells launches in,
Date Preference in the Interactive Well Site, Auto Catalog
selection and view SAM connection information.
•
OpenWells Classic Button - Switch the application to OpenWells Classic
mode
5000.1.7
Page 139 of 423
Draft
•
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Properties
The current Well, Wellbore, Event, Rig, Rig On Location date and the reporting
interval are displayed at the top left corner of the surface image. The items listed
in blue are also links that open various pages when selected. The Well, Wellbore,
Event and Rig links open their respective Properties dialogs and the On Location
link opens the Rig Operations dialog.
Draft
Figure 8: Identify the current context
Data Entry Links
Each canvas contains links to WYSIWYG and Report forms where data is entered
by the users. Clicking on a link displays a form where data can be entered on the
item. Forms can be opened in the following ways:
•
click on one of the colored images
Figure 9: Select the Cement truck to open the Cementing Details form
5000.1.7
Page 140 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
click on the blue Activities link and then select the activity type
Draft
Figure 10: Select the Activities link to access WYSIWYG and Report entry forms for
numerous well site activities
•
click on the blue Daily Operations link and then select the daily activity type
Figure 11: Select the Daily Operations link to access WYSIWYG entry forms for a
number of Daily activities
A complete listing of clickable items is available in the OpenWells online help topic,
Image Map.
Data Indicators
The Surface and subsurface canvases also contain visual indicators showing
users what data has been entered and what data entry is complete on a given day.
5000.1.7
Page 141 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
A yellow checkmark appears next to an item on the Interactive Well Site to indicate
that data exists on the current day for the item. Once all data has been entered and
reviewed, activate the Section Complete checkbox located at the top of the form.
The yellow checkmark turns green to indicate that the data entered today for the
item is complete.
Draft
Figure 12: Yellow checkmarks indicating data exists and green checkmarks indicating
data is complete
Data Entry
WYSIWYG and other forms are now only one or two clicks away from the main
Canvas window.
EDM Administrators can create their own WYSIWYG forms in the EDM
Administration Utility and assign them to canvases. For the 5000.1.7.0 release, the
creation of WYSIWYG forms is limited to certain database tables. Contact
Landmark Support for more information.
WYSIWYG forms help increase data entry ease and efficiency. Each WYSIWYG
form can also be printed from the form window and will print out exactly as it is
appears in the data entry window.
5000.1.7
Page 142 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 13: Sample of the BHA Run WYSIWYG Form including the Wellbore Schematic
Synchronize Data
EDM AutoSync has been fully integrated into the Interactive Well Site. Data can
now be synchronized between the Rig and Regional Office via EDM AutoSync with
a single-click on the Satellite Dish found on each of the Canvases.
For more information on EDM AutoSync, see “EDM AutoSync Server and EDM
AutoSync Client (available separately from LSM)” on page 4.
Figure 14: AutoSync Satellite Dish
5000.1.7
Page 143 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
New Select Partners Button
A new Select Partners button allows users to select Partners and Contacts to add
to the Associated Partners spreadsheet. This button is available in the Event,
Wellbore and Well Properties dialogs.
Draft
Figure 15: Select Partners feature
New Copy Plan Formations Button
A new Copy Plan Formations button has been added to the Wellbore Properties
Formation tab. This button allows users to copy formations from planned designs
created in COMPASS™ for use by the Wellbore. This feature overwrites any
existing formations. During the copy process, if the application detects that a
formation is already associated with a report, the copy process is cancelled.
Figure 16: Copy Planned Formations feature
5000.1.7
Page 144 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Wellbore Status Notes
A new column has been added to the Wellbore Status spreadsheet in the Wellbore
Properties dialog.
Draft
Figure 17: New Notes column
Close Rig Event Association
When an Event is closed (i.e., its End Date is entered), the application prompts the
user to close the associated Rig Operation.
Final Report Checkbox Populates Event End Date
When the Final Report checkbox is activated in the Daily Operations General
section, the Daily Report's Date is copied to the Event End Date field.
This feature only works if the system setting SetEndDatesToFinalReport is set to
YES in the EDM Administration Utility.
Figure 18: Final Report / Event End Date feature
Update Time Summary Button
To reduce data entry time and duplication, the Update Time Summary button has
been added to the OpenWells application. This button allows users to push data
entered in specific reports directly into a new row in the Time Summary
spreadsheet.
5000.1.7
Page 145 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Using the EDM Administration Utility’s Layout Manager, Administrators can
configure the source fields where the data will be entered and the destination
DM_ACTIVITY fields the data will be pushed to. The Update Time Summary button
is available in the following areas:
•
Classic Entry Form General Section: Casing, Cementing, Perforation,
Stimulations and Wellbore Equipment
•
WYSIWYG Forms: Casing, Cementing and Stimulations
1. Enter data and select the Update Time Summary button.
Draft
2. Verify the data has been entered correctly.
3. The date is pushed to the
Time Summary spreadsheet.
The link will open the reot.
Figure 19: Update Time Summary Feature
New Time Summary Fields
Three new fields have been added to the Time Summary spreadsheet to record
descriptions of Class, Code and Subcode. The fields are Class Description, Code
Description and Subcode Description. These fields are not included in the default
layouts and must be added in the OpenWells Layout Manager.
5000.1.7
Page 146 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Calculation Change in Time Summary
The Total Time field now calculates the total Duration for the selected Activity
Group Filter, instead of for all Critical Path rows regardless of the selected Activity
Group Filter.
Total Time for All Groups
Draft
Total Time for “Group A” only when selected in Filter
Figure 20: Time Summary Total Activity Time Calculation
Personnel Data Entry Improvements
The layout of the Personnel section in the Daily Operations report and WYSIWYG
has changed to improve daily workflows and previous limitations. Company and
Employee information is now managed from in a separate dialog.
•
Data recorded in the Personnel section now correctly represents the Company
or Personnel's presence on site for that reporting day.
•
Deleting a row in the Company Onsite or Personnel Onsite tabs no longer
deletes the Company or Personnel; it only deletes the record of their presence
at the well site on that day.
•
A new Edit Company/Personnel button allows users with the correct
permissions to add, modify or delete the list of available Companies and
Employees. This button also allows users to copy Companies and Employees
from other existing Events.
5000.1.7
Page 147 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 21: Edit Company/Personnel feature
•
A new Select Company/Personnel button allows users to select a number of
Companies and Employees and adds them to the Companies Onsite and
People On Board spreadsheets.
Figure 22: Company/Personnel quick picker
BHA Length Calculation Change
The BHA Length calculation has been changed to include Drill Pipe located
between other components in the string. The BHA Length is now calculated as
follows:
BHA Length = ∑ all Component Lengths - the Drill Pipe Component Length at
the top of the string
5000.1.7
Page 148 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Only the first section of Drill Pipe located at the top of the string is not included in
the calculation.
Drill Pipe not used
in BHA Length Calc.
Draft
Drill Pipe used
in BHA Length Calc.
Figure 23: BHA Length Calculation and Drill Pipe components
New Bit Operations Calculated Fields
Three new Calculated Fields added to Bit Operations table DM_BIT_OP: Guided
Percent, Op Sum Hours and Op Sum Progress.
Bit Details Total Flow Area Calculation
The TFA (Total Flow Area) is now an editable calculated field. By default, the field
is calculated, but a user can override the calculation by editing the field directly. If
the user changes fields that this calculation depends on or selects the calculated
field and clicks the Calculated Current Field button in the toolbar, the application
re-calculates the TFA.
Flip Component Order Feature
A new button Flip BHA (or Flip Order) has been added to reverses the order of the
Components in the spreadsheet, as well as, in the database. This button helps
users correct a simple mistake without having to manually move each component
or reenter their data. The Flip BHA button is available on the Components tab of
the Drillstrings section and the Work Strings sections in the Daily Operations,
Coring, Logging, Perforation, Sidewall Coring and Stimulations forms.
5000.1.7
Page 149 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
1. Component Order Before
2. Select Flip BHA Button
Draft
3. Component Order After
Figure 24: Flip BHA (or Flip Order) Button
Non Productive Time (NPT) Administration Tokens
New tokens have been added to the EDM Administration Utility to allow
administrators to restrict a user's rights to add, edit, view, delete and lock NPT data.
The tokens are:
•
OpenWells.NPT.add,
•
OpenWells.NPT.delete,
•
OpenWells.NPT.edit,
•
OpenWells.NPT.view
•
EDM.Explorer.NPT.lock.
Kick Tests
A new area has been added to the Daily Operations Report's Safety section. This
section allows users to records Kick Tests on a daily basis.
5000.1.7
Page 150 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Fluid Produced Spreadsheet
A new spreadsheet has been added to the Fluid Handling tab to record fluids
produced. Two new calculated fields: Mud Produced and Mud Discharge have
been added to the Fluid Losses tab. These new items only appear if the
FluidProduced System Setting is set to YES. For information on the system setting,
see the EDM Administration Utility online help.
Work Strings Section
A new Work String section has been added to the Coring, Logging, Perforation,
Sidewall Coring and Stimulations areas. These sections allows users to enter
details of the assemblies run downhole directly in the related report. The Work
String section operates in the same way as the Daily BHA Run area.
Cement Plug for Open Hole
The Casing Assembly picklist includes a “None” item for all Cement Job Types.
This item allows users to create a cement job that is not associated to the Casing
assembly string.
Any Job Type selected
-None- option in Assembly picklist
Figure 25: No Casing Assembly associated ot Cement Job
Cement Plug Drill Out Date
A checkbox and date field have been added to the Cement report to record the date
a cement plug was drilled out.
5000.1.7
Page 151 of 423
May 2010
Draft
Job Activity Section
A new Job Activity section has been added to the Coring, Logging, Perforation,
Sidewall Coring and Stimulation reports. This new section allows users to enter
specific Time Summary operation details directly in the report form.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Cement Intermediate Circulations Section
A new section has been added to the Cementing report to record circulation
operations during the cementing.
Calculate Cement Stage Top/Base MD based on the Pumping Schedule
Two new system settings have been added to the EDM Administration Utility
(TopBaseSlurryAndTests and TopBaseSlurryAndTestsCodes), which determine
the Top MD and Base MD of a Cement Stage, based on the Fluids entered in the
Pumping Schedule.
Results Section
A new section has been added to the Fishing Report to record the outcome of the
fishing operation.
Auto Save Feature
A new AutoSave system setting has been added to allow Administrators to sets the
number of minutes between the OpenWells Reports saving automatically. This
setting is only applicable to OpenWells Classic mode. It does not apply to the
Interactive Well Site. For more information see the EDM Administration Utility
online help.
Figure 26: AutoSave System Setting
Internal Picklist Configuration Additions
Prior to this release, Internal Picklists were not editable by Administrator or users.
Now users with appropriate permission to the Data Dictionary Picklist
configuration, can add data to supplement the picklist
5000.1.7
Page 152 of 423
May 2010
Draft
Responsible Parties Section
A new section has been added to the Fishing Report to identify those responsible
for the fishing operation. These names can be carried over from one Fishing report
to the next.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
The following rules apply to internal picklists:
And Filter Clause
Add, Delete, Sort Internal Picklist
Figure 27: Internal Picklist Changes
New Hole Plan Calculations
Four new calculations have been added to the Hole Plan spreadsheet in the Well
Planning report: Cum Target Duration, Cum AFE Duration, Cum AFE Cost and
Cum Target Cost. Cum Target Duration.
5000.1.7
Page 153 of 423
May 2010
Draft
— Table Name and Picklist Type cannot be changed
— Filter clauses cannot be added
— And Filter clauses can be added. The And Filter is applied after the Filter
Clause and any internal filters
Note: The And Filter Clause may be greyed out for any internal picklists,
whose internal filtering is too complicated to run additional SQL queries
against.
— Picklist Options cannot be changed
— Columns displayed in the dropdown defined by the application cannot be
edited or removed
— New Columns Displayed in the dropdown can be added and deleted
— Fields Updated defined by the application cannot be edited or removed
— New Fields Updated can be added and edited
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 28: New Hole Plan calculated fields
Access Online Help from a Server
When OpenWells is installed using the Client installation, the application now
automatically calls the Online Help from the Server location. During the installation
the registry key HKEY_LOCAL_MACHINE\SOFTWARE\Landmark Graphics
Corporation\EDT\<version number>\Installation Type is checked to verify if the
installation mode is client or local. If it is Client the registry key retrieved is
“ServerFolder”. Otherwise, the registry key retrieved is “Installation Folder”.
Release 5000.1.6
There are no enhancements for the OpenWells 5000.1.6 release.
Release 5000.1.5
•
Multiple MAASP Status Readings - The OpenWells® application now allows
Well Engineers to record the changing state of Maximum Allowable Annular
Surface Pressure (MAASP) values over the life cycle of a Well. 

The new spreadsheet fields use a different EDM™ table (CD_WELL_MAASP)
than the old fields (CD_WELL) appearing in the General tab.
•
Approval Process - The OpenWells and PROFILE applications now includes a
feature to mark and identify Wells, Events and Reports that have gone through an
5000.1.7
Page 154 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
approval process. The approval process preserves and locks the information
recorded about the Well/Event/Report at the time of approval.
•
AutoSync Well Assignment - Defined OpenWells'® users are now able to assign
Wells to an AutoSync Client for bi-directional updates between Rig and Regional
EDM databases.
•
New Report Manager Version - A new Report Manager version, which will reduce
memory consumption, increase report generation speed, and contains various
other improvements.
This new feature has been added as a spreadsheet in the Well Properties - Status
tab.
The old MAASP entry fields are still available in the Well Properties - General tab
and should be hidden or made read-only by the EDM™ Administrator as not to
confuse users. If MAASP values have been entered in the General tab entry fields,
a row is automatically be created in the MAASP spreadsheet.
The new spreadsheet fields use a different EDM™ table (CD_WELL_MAASP)
than the old fields (CD_WELL) appearing in the General tab.
5000.1.7
Page 155 of 423
May 2010
Draft
Multiple MAASP Status Readings
The OpenWells® application now allows Well Engineers to record the changing
state of Maximum Allowable Annular Surface Pressure (MAASP) values over the
life cycle of a Well. Recording changes to MAASP on a Well creates a history that
can be used in recognizing any concerning trends in changes to these pressure
values.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Data Approval
The OpenWells® and PROFILE™ applications now include a feature to mark and
identify Wells, Events and Reports that have gone through an approval process.
The approval process preserves and locks the information recorded about the
Well/Event/Report at the time of approval. The information preserved for a Well
includes the Well’s data and its Events, Wellbores, Completions, Designs and
Reports data. The information preserved for an Event includes the Event’s data
and its Reports.
Note:
Reports can only be approved within the OpenWells® application.
Further edits to any of the locked data requires unlocking of the Well, Event,
Wellbore, Completion, Design or Report by a user with the appropriate privileges.
5000.1.7
Page 156 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
During the approval process the data is preserved via a database snapshot,
creating an approval point. Approval points can be compared to a previous
approval points of the same data element. For example, a Well’s approval point
can be compared to the last approval point of that same Well. Well, Event and
Report approval points cannot be compared to one another.
Any PDF files that are attached to an approval point are electronically signed when
a Well, Event or Report is prepared for approval and when the Well, Event or
Report is approved. The location of the Approval Point PDF stamps in the
OpenWells and PROFILE applications can be configured using a system setting.
See the PDF Approval Stamp topic in the EDM™ Administration Utility online help.
The approval process consists of two separate workflows:
•
the preparation of the data for approval,
•
and the approval (or rejection) of the prepared data.
These processes are outlined in the OpenWells and PROFILE online help
systems.

New tokens have been added to the EDM™ Administration Utility to support the
new Approval feature.
Updating an Oracle Database to use the Historian Service
Prior to running a database upgrade on Oracle, the Database Administrator will
have to run the hist_tbs.sql script to create the EDMHIST1 tablespace. Without this
tablespace the database update will fail. This script is extracted during the 5000.1.5
install, with the Database Upgrade scripts to
C:TEMP\EDM_5000_1_2_SQL_Update folder.
Configure the Wrapper.conf File
The Wrapper.conf file defines the service parameters for the Historian Service.
This file requires access to the EDT Installation folder and is installed in the same
location as the EDT Installation folder, in the Historian/conf folder.
By default, the wrapper.conf looks for the EDT installation folder named
‘EDT_5000.1’. If the EDT installation folder is not named ‘EDT_5000.1’, then the
wrapper.conf file must be edited to look for the correct folder containing the EDT
installation.
5000.1.7
Page 157 of 423
May 2010
Draft
Prior to preparing a Well, Event or Report for approval, the LGC EDM Historian
service must be configured.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
To edit the wrapper.conf file, open the file in a text editor, such as Notepad, and
change the value of the following line.
wrapper.java.command=../../EDT_5000.1/Common Files/JDK/bin/javaw
For example, if the EDT installation folder in named ‘Landmark Apps’, then this line
should read as follows:
wrapper.java.command=../../Landmark Apps/Common Files/JDK/bin/javaw
Configure the LGC EDM Historian Service
Only one instance of the LGC EDM Historian service needs to be configured for
each database being used.
1. To configure the Historian service on the machine hosting the service,
open the Windows Computer Management > Services interface and
stop the LGC EDM Historian service.
2. Check the security permissions for the Historian Service via the Log On tab
in the historian service properties dialog. If the COE does not permit
services to run as a local system account, then appropriate account
credentials must be configured here for the service to run.
3. Launch the EDM Administration Utility and select the Historian Service ()
node.
Security Note:
The Administrator must be granted access to the Admin.Historian.edit token
to access the Historian Service in the EDM Administration Utility.
4. Enter the credentials for the database connections and ports.
5000.1.7
Page 158 of 423
May 2010
Draft
The LGC EDM Historian service stores approval point snapshots and compares
differences between approval points. Prior to the preparing an approval point or
approving a Well, Event or Report, this service must be configured.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
5. Click the Save button to save the credentials.
7. Once the service has started, wait approximately 10 seconds to verify that
the service continues to run. If any of the above connection details are
incorrect the service will stop shortly after starting.
Log Note:
The historian service logs events and errors to <Historian Installation Directory>\Historian\logs. In the event of a service failure it may be useful to inspect these logs to determine the cause (e.g., incorrect connection
information, username password not accepted etc.).
Release 5000.1.4
The OpenWells® 5000.1.4 release is an incremental update to the Engineer’s
Desktop™ 5000.1.0 release. The primary focus of this release has been to enhance
the user experience and to expedite user workflows. This has been accomplished
through the addition of the following features:
•
Rig to Event/Report Association Improvements - A number of changes have
been made to the Rig Event/Report associations to improve the usability and
flexibility of associations. The changes are summarized in the following scenarios
outlined later in this document.
—
—
—
—
—
5000.1.7
Only Currently Active Rigs are Available for Association
Associate Rig Operations to an Event with existing Daily Reports
The Wrong Rig is Associated to an Event
Rig Operations “On Location” Date Change
Associate a Rig Operation to an Event that already has an “active” Rig
Operation
Page 159 of 423
May 2010
Draft
6. Open the Windows Computer Management > Services interface and
start the LGC EDM Historian service.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
•
— Deleting Rig Operations
— Changing the Daily Operations Report Properties
TVD Calculations System Setting - A new System Setting
“AllowProjectedTvdCalc”, has been added to allow Administrators to select how
they want the application to respond when the current MD does not have an active
survey available to calculate the current TVD.
WITSML Halliburton SUMMIT™ Integration - OpenWells® software now
supports the import of WITSML Stimulations data from the Halliburton SUMMIT™
application into the OpenWells® application.
•
Associating Rig Operations to Events - Rigs can be associated to Events
from a number of locations in the application. The scenarios outlined in this
document deal with Rig associations using the Associate Rig Operation to
Event Wizard and the Associate Rig to Daily Wizard. These Wizards are
accessed from a number of locations in the application:
•
Associate Rig Operation to Event Wizard
— select the Event, follow the menu path: File > Associate > Rig
Operation...
— right-click the Event and select Associate >
Rig Operation
— in the Event Properties dialog’s Associated Rig Operations Tab, click the
(Add Rig Operation) button.
•
Associate Rig to Daily Wizard - These options are only available if a Rig has
not already been associated to the Daily Operations report.
— in the Create Daily Report Wizard, select the Associate Rig... button.
— in the Daily Operations report's Rig Equipment sections (e.g., Pump
Operations section), click the Associate Rig button.
Scenario A: Only Currently Active Rigs are Available for Association
When creating an association between an Event or Daily Operations report and
a Rig Operation, the list of Rigs with available Rig Operations that CAN be
associated are now filtered. The OpenWells® application will only show Rigs
which are currently active.
A Rig is defined as currently active if:
5000.1.7
Page 160 of 423
May 2010
Draft
Rig Changes
This section contains important information on changes to the Rig and Event
associations in the OpenWells® 5000.1.4 application. These changes inform the
users of the effects of associating a Rig to an Event, when Daily Operations reports
exist for the Event.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
its Start Date is null OR less than OR equal to the current date
AND
its End Date is null OR greater than OR equal to the current date
Draft
Figure 29: Of the 5 GLOBAL MARINE DRILLING Rigs, only 3 are available in the
Associate Rig Operation to Event Wizard. This is a result of the new Rig filtering feature.
Scenario B: Associate Rig Operations to an Event with existing Daily Reports
At the time a Rig Operation is associated to an Event, any existing Daily
Operations reports within the Event that fall within the “Rig On Location” date
range WILL be updated with the new associated Rig Equipment data. The
following example illustrates this new feature.
An Event that has no Rig Operations associated to it contains two Daily
Operations reports. As a result of the lack of an association these Daily
Operations reports do not have Rig Equipment listed.
5000.1.7
Page 161 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
No Rig Association
Draft
Figure 30: Event showing no associations and Daily Operations reports showing no
Rig Equipment.
When the Event is associated to the ALPINE/N15 Rig a dialog appears
informing the user that the two existing Daily Operations reports will be updated
with the new Rigs data.
Figure 31: Associate Rig Operation to Event Wizard with message showing the Daily
Operations reports that will be updated.
After the Association has been made, the reports now display the Rig Name in
the title bar and any equipment “installed” on the Rig are listed within the report.
5000.1.7
Page 162 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Associated Rig
Draft
Figure 32: Rig association shown in the Event Properties and the Daily Operations
Report showing the associated Rig and Rig Equipment data.
Scenario C: The Wrong Rig is Associated to an Event
After a Rig Operation is associated to an Event, the user realizes that they had
selected the wrong Rig. The OpenWells® application allows the user to remove
the associated Rig and select the correct Rig for association.
In the Event Properties > Associated Rig Operations tab, the user selects the
row containing the Rig Operation to be removed and clicks the
(Remove
Associated Rig Operation) button. All Daily Operations reports, within the
Event, that are currently associated with the Rig and within the Rig’s date
range, will have their Rig Equipment operations data deleted and Rig
association remove. A message appears showing the reports affected by the
removal.
If this was the only association for the Rig Operation, then the Rig Operation is
also deleted.
5000.1.7
Page 163 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Figure 33: Message listing the Daily Operations reports affected by the Rig Association removal.
As in Scenario B, when the Event is associated to the correct Rig a dialog
appears informing the user that the existing Daily Operations reports will be
updated with the new Rig’s data.
Figure 34: Associate Rig Operation to Event Wizard with message showing the Daily
Operations reports that will be updated.
Scenario D: Rig Operations “On Location” Date Change
When a user changes the Rig Operation’s Rig On Location date, existing Daily
Operations reports may be affected in one of the following ways.
Reports fall outside the Rig “On Location” date range
The new Rig On Location date puts currently associated Daily Operations
reports outside of the Rig Operation’s “On Location” date range. The
OpenWells ® application responds to this action by displaying a message
notifying the user of any Daily Operations reports that are now outside of the
“On Location” date range. The reports are NOT updated by the change in date.
5000.1.7
Page 164 of 423
May 2010
Draft
The use can now associate the correct Rig/Rig Operation with the Event.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 35: Rig On Location date is changed from 02/15/2009 to 03/15/2009, which
pushes two Daily Operations reports outside the Rig “On Location” date range.
Reports that were outside the Rig “On Location” date range are now within
range
The new Rig On Location date puts currently associated Daily Operations
reports, which were outside of the Rig Operation’s “On Location” date range,
within the date range. The OpenWells® application responds to this action by
displaying a message notifying the user of any Daily Operations reports that are
now within the “On Location” date range. The reports are NOT updated by the
change in date if they were previously within range.
5000.1.7
Page 165 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 36: Rig On Location date is changed from 03/15/2009 to 02/15/2009, which
pushes two Daily Operations reports within the Rig “On Location” date range.
Scenario E: Associate a Rig Operation to an Event that already has an “active”
Rig Operation
A new Rig Operation is associated to an Event that has an existing “active” Rig
Operation association. The OpenWells® application prompts the user to update
any affected Daily Operations reports with the new Rig Operation data or leave
the report with its existing Rig Operation data.
Once the new association is complete, the application displays a dialog where
the user can choose whether or not to update each affected Daily Operations
report.
— If the user chooses to update a report, then the Update button next to
that report should be clicked.
— If the user does not want to update a report, then the Update button
should NOT be clicked. 
When a report is updated its text turns blue in the dialog.
Figure 37: Dialog allowing the user to choose which reports are to be associated to the
5000.1.7
Page 166 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
new Rig Operation. The blue text indicates the report has been updated.
•
Deleting Rig Operations
If a Rig Operation is associated to an Event/Daily it can no longer be deleted in
the Contractors tree. When a user attempts to delete the Rig Operation in the
Contractors tab the following message appears.
To delete a Rig Operation that is associated to an Event, the user must remove
it in the Event Properties dialog.
In the Event Properties > Associated Rig Operations tab, the user selects the
row containing the Rig Operation to be removed and clicks the
(Remove
Associated Rig Operation) button. All Daily Operations reports, within the
Event that are currently associated with the Rig will have their Rig Equipment
deleted and the association is removed. If this was the only association for the
Rig Operation, then the Rig Operations is also deleted.
Figure 39: Message listing the Daily Operations reports affected by the Rig Association
•
Changing the Daily Operations Report Properties
The OpenWells® application now allows users to change the Rig/Rig Operation
associations from the Report Properties dialog of a Daily Operations report.
The Daily Operations Report Properties dialog is accessed from the following
locations:
5000.1.7
Page 167 of 423
May 2010
Draft
Figure 38: Message indicating the Rig Operation cannot be deleted due to it’s association with one or more Events.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
— From within the report window follow the menu path: File > Properties...
— Right-click on the report in the Report List and select Properties... from
the menu that appears
Changing the Rig and Rig Operation from the Report Properties Dialog
The Rig Contractor, Name, No field’s picklist displays a list of Rig’s available
for association to the Daily Operations report. Only Rigs which are “On
Location” during the Report’s date are shown in this list. The selected Rig is
currently associated to the report.
Draft
Figure 40: Report Properties dialog showing the Rig picklist.
The currently associated Rig Operation can be changed using this picklist.
When the user selects a different rig from this picklist and the current
associated Rig has Rig Equipment Operations, the application informs the user
of the equipment operations that will be deleted. The users can then choose to
delete the operations or cancel the change.
5000.1.7
Page 168 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Figure 41: Message indicating how many Rig Operations will be affected by the
change in association.
Changing the Report Date from the Report Properties Dialog
Figure 42: Message indicating how many Rig Operations will be affected by the
change in Report Date.
If the user chooses to proceed with the date change, the Rig Contractor,
Name, No picklist will be set to --None-- and any related Rig Equipment
Operations will be deleted from the Report.
OpenWells® TVD Calculations
The OpenWells® application now allows Administrators to selected how they want
the application to respond when the current MD does not have an active survey
available to calculate the current TVD.
A new System Setting “AllowProjectedTvdCalc” has been added to the EDM™
Administration Utility to define how OpenWells handles the calculation of the
current TVD when a survey is not available for the current MD.
The “AllowProjectedTvdCalc” System Setting defines the TVD calculation as
follows:
•
5000.1.7
When set to FALSE, the application will not calculate the TVD for a MD that has
no active survey and will display a null value.
Page 169 of 423
May 2010
Draft
When the user changes the Report Date in the Properties dialog, and the new
date falls outside of the Rig “On Location” date range, the application informs
the user of the equipment operations that will be deleted. The users can then
choose to delete the operations or cancel the change.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
When set to TRUE, the application uses the closest survey to calculate the TVD
of a MD that has no active survey.
The following table illustrates TVD calculations when using the new System
Setting.
Scenario
TVD Calculation Behavior
Calculate TVD using the survey being recorded by the
drilling supervisor. (Independent of the system setting for
survey projection)
MD has been recorded by the drilling
supervisor on a day with no survey
stations being recorded.
Calculate TVD using the survey being recorded by the
drilling supervisor, even though a station was not recorded
today. (Independent of the system setting for survey
Days with ongoing operations (i.e.
Casing/Cementing) but no progress in
MD and no further survey stations
recorded past the last station during
drilling.
TVD is that of the last day of drilling prior to the operations
with no progress. This TVD should not change until
progress is made and a new survey entered (i.e. even if a
survey is entered for a deeper interval it should not affect
the TVD during ongoing operations with no progress).
(Independent of system setting for survey projection)
Vertical well ("post hole") with a survey
in a depth interval drilled prior to the
current depth interval.
Calculate TVD using the survey from the previous interval
when the system setting for survey projection is enabled.

TVD is blank when the system setting for survey projection
is disabled.
A depth interval that does not deviate
from the last inclination and azimuth of
the previous interval (non-vertical, nondeviating hole section).
Calculate TVD using the survey from the previous interval
when the system setting for survey projection is enabled.

TVD is blank when the system setting for survey projection
is disabled.
A depth interval that deviates from the
last inclination and azimuth in the
previous interval.
Calculate TVD using the survey from the previous interval
when the system setting for survey projection is enabled.

TVD is blank when the system setting for survey projection
is disabled.
Vertical well ("post hole") with no
surveys for any depth intervals.
Calculate TVD equal to MD when the system setting for
survey projection is enabled.

TVD is blank when the system setting for survey projection
is disabled.
5000.1.7
Page 170 of 423
May 2010
Draft
MD and today's survey station have
been recorded by the drilling supervisor.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Halliburton SUMMIT™ Integration
OpenWells® software allows for the import of Stimulations data from the
Halliburton SUMMIT™ application using WITSML 1.3.1.1 standards.
WITSML 1.3.1.1 Standards:
The workflow outlined here is still in the process of being approved by the
WITSML community.
Stimulation data imported includes:
—
—
—
—
—
—
—
—
•
DM_STIM_FET_TEST
DM_STIM_FLOWPATH
DM_STIM_FLOWPATH_STAGE
DM_STIM_PUMP_FB_TEST
DM_STIM_PUMPING_DIAG
DM_STIM_RES_INTERVAL
DM_STIM_STAGE_SUPPLEMENT
DM_STIM_STEP_TEST
Importing Halliburton SUMMIT™ WITSML XML into OpenWells® software
The following flowchart outlines the workflow for importing Stimulations data
from into the OpenWells® application using WITSML XML files generated by
the Halliburton SUMMIT™ application.
5000.1.7
Page 171 of 423
May 2010
Draft
— Intervals
— Flow Paths
— Stages
— Fluids
— Proppant
— Additives
— PDAT Session
— Step Tests
— Reservoir Intervals
— Stimulation FET Tests
— Pump Flowback Tests
Some of the Halliburton SUMMIT™ data imported is not exposed in the
OpenWells® application. This data can still be queried in the Data Analyzer™
application from the following OpenWells® tables:
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
A step by step guide to importing Halliburton SUMMIT™ WITSML XML data
into OpenWells® can be found in the “Importing Halliburton SUMMIT
Stimulations Data” online help topic.
Draft
5000.1.7
Page 172 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Obtain WITSML XML
files from Halliburton
Log into OpenWells.
Do I have a
Stimulations Report?
No
Draft
Create a Stimulations
Report.
Select the Create New Report
button in the Wizard toolbar.
Select “Stimulation” in the
Report Type list.
Yes
Select the Company, Project,
Site, Well, Wellbore and Event.
Click the Next button.
Enter the correct Report
Date and a brief
description.
Open the Stimulation Report.
Click the Finish button.
The Stimulation Report
opens.
5000.1.7
In the Report window, follow
the menu path, File >
WITSML > Import.
Page 173 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Navigate to and select the
WITSML XML export file.
Click the Open button.
Draft
Click the Import button.
Select the XML file containing
the datum information and
click the Select button.
Yes
Do you have a XML file
containing the Well’s
datum information?
Click the Select button.
Click the Cancel button.
If the Well file selected does not
contain a valid datum (i.e., missing
or zero), then the EDM™ Default
Datum is used.
If the EDM™ Default Datum does
not give the correct offset for the
data being imported, all depths
being imported will be incorrect.
5000.1.7
No
Page 174 of 423
OpenWells® software uses the
EDM™ Default Datum defined in
the Well Properties, Depth
Reference Tab.
If the EDM™ Default Datum does
not give the correct offset for the
data being imported, all depths
being imported will be incorrect.
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Does data already exist in
the Stimulations report?
Replace
Do you want to Replace the
existing data or Append to the
existing data?
Draft
Yes
No
The Stimulations data is
imported from the XML file into
the Stimulations Report.
Append
The Stimulations data is imported
from the XML file into the Stimulations
Report an overwrites all existing data.
The Stimulations data is imported from the XML
file into the Stimulations Report and appended
to the existing data. With the exception of data
appearing in the General section of the report.
This data is updated or overwritten.
5000.1.7
Page 175 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
WITSML to OpenWells Mappings
The following table outlines the mappings used to move data from the WITSML
1.3.1 XML file generated in the Halliburton SUMMIT™ application to the EDM™
Database.
WITSML Schema
WITSML Attribute
EDM Table
EDM Column
obj_stimJob.xsd
EDM Import Rule
Set
DM_STIM_JOB.PHASE
to ACTUAL
nameWell
obj_stimJob.xsd
name
obj_stimJob.xsd
version
obj_stimJob.xsd
uid
obj_stimJob.xsd
uidWell
obj_stimJob.xsd
uidWellbore
Draft
obj_stimJob.xsd
grp_stimJob.xsd
grp_stimJob.xsd
jobType
DM_REPORT_JOURNAL
description
update existing field
and truncate to 50
from 64 if needed
grp_stimJob.xsd
serviceCompany
DM_STIM_JOB
contractor
update existing field
and truncate to 60
from 64 if needed
grp_stimJob.xsd
supervisor
DM_STIM_JOB
supervisor
update existing field
grp_stimJob.xsd
apiNumber
grp_stimJob.xsd
nameStimJob
grp_stimJob.xsd
customerName
grp_stimJob.xsd
timeOnLocation
DM_STIM_JOB
contractor_arrival_date
update existing field
grp_stimJob.xsd
startTime
DM_STIM_JOB
job_date
update existing field
grp_stimJob.xsd
totalPumpTime
grp_stimJob.xsd
MaxJobPressure
DM_STIM_TREATMENT
max_job_pressure
used in the calculation
of
DM_STIM_JOB.max_tr
eating_pressure
grp_stimJob.xsd
MaxFluidRate
DM_STIM_JOB
max_injection_rate
not imported
(calculated from
DM_STIM_TREATMENT
.inject_rate_max)
grp_stimJob.xsd
AvgJobPressure
DM_STIM_JOB
avg_treating_pressure
not imported
(calculated)
grp_stimJob.xsd
volJob
DM_STIM_JOB
total_fluid_pumped
not imported
(calculated)
grp_stimJob.xsd
totalProppantWt
DM_STIM_JOB
total_proppant_used
update existing field
grp_stimJob.xsd
proppantName
5000.1.7
Page 176 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Schema
WITSML Attribute
EDM Column
EDM Import Rule
grp_stimJob.xsd
totalPerfBalls
grp_stimJob.xsd
totalN2
DM_STIM_JOB
n2_total
not imported
(calculated)
grp_stimJob.xsd
totalCO2
DM_STIM_JOB
co2_total
not imported
(calculated)
grp_stimJob.xsd
hhpOrdered
grp_stimJob.xsd
hhpUsed
DM_STIM_JOB
total_hydraulic_hp
not imported
(calculated)
grp_stimJob.xsd
fluidEfficiency
DM_STIM_TREATMENT
fluid_efficiency
Carry over for each
interval
grp_stimJob.xsd
flowBackPressure
DM_STIM_FLOWBACK
pressure_30_min
create a
DM_STIM_FLOWBACK
record for this job if
there is data. Populate
sequence_no.
grp_stimJob.xsd
flowBackRate
DM_STIM_FLOWBACK
flowback_rate
create a
DM_STIM_FLOWBACK
record for this job if
there is data.
grp_stimJob.xsd
flowBackVolume
DM_STIM_FLOWBACK
flowback_volume
create a
DM_STIM_FLOWBACK
record for this job if
there is data.
grp_stimJob.xsd
numOfTreatmentInterv
als
grp_stimJob.xsd
bhStaticTemperature
grp_stimJob.xsd
treatingBHTemperatur
e
cs_stimJobInterval.xsd
cs_stimJobInterval.xsd
avgFractureWidth
DM_STIM_TREATMENT
prop_width_average
update existing field
cs_stimJobInterval.xsd
avgConductivity
DM_STIM_TREATMENT
conductivity_average
do not import since
WITSML units cannot
be converted to EDM
units
cs_stimJobInterval.xsd
netPressure
DM_STIM_TREATMENT
net_pressure
update existing field
cs_stimJobInterval.xsd
closurePressure
DM_STIM_TREATMENT
closure_pressure
update existing field
cs_stimJobInterval.xsd
closureDuration
cs_stimJobInterval.xsd
uidTreatmentInterval
cs_stimJobInterval.xsd
treatmentIntervalNam
e
DM_STIM_TREATMENT
job_type
Format with "Interval:
", truncate to 50
cs_stimJobInterval.xsd
treatmentNumber
DM_STIM_TREATMENT
sequence_no
Start at max existing
plus 1 and increment,
to avoid duplicates. If
none present, start at
0.
cs_stimJobInterval.xsd
treatmentIntervalStart
Time
DM_STIM_TREATMENT
time_start
cs_stimJobInterval.xsd
formationName
DM_STIM_TREATMENT
zone
5000.1.7
Page 177 of 423
truncate to 50 if
necessary
May 2010
Draft
EDM Table
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Attribute
EDM Table
EDM Column
EDM Import Rule
cs_stimJobInterval.xsd
mdFormationTop
DM_STIM_TREATMENT
interval_top
rdl depth
cs_stimJobInterval.xsd
mdFormationBottom
DM_STIM_TREATMENT
interval_base
rdl depth
cs_stimJobInterval.xsd
tvdFormationTop
cs_stimJobInterval.xsd
tvdFormationBottom
cs_stimJobInterval.xsd
mdPerforationsTop
cs_stimJobInterval.xsd
mdPerforationsBottom
cs_stimJobInterval.xsd
tvdPerforationsTop
cs_stimJobInterval.xsd
tvdPerforationsBottom
cs_stimJobInterval.xsd
numberOfPerfs
cs_stimJobInterval.xsd
perfSize
cs_stimJobInterval.xsd
perfFrictionFactor
cs_stimJobInterval.xsd
mdJetTargetTop
cs_stimJobInterval.xsd
mdJetTargetBottom
cs_stimJobInterval.xsd
tvdJetTargetTop
cs_stimJobInterval.xsd
tvdJetTargetBottom
cs_stimJobInterval.xsd
numberOfJetTargets
cs_stimJobInterval.xsd
jetTargetSize
cs_stimJobInterval.xsd
totalFrictionPressureLo
ss
cs_stimJobInterval.xsd
totalPumpTime
cs_stimJobInterval.xsd
maxPressureTubing
cs_stimJobInterval.xsd
maxPressureCasing
cs_stimJobInterval.xsd
maxPressureAnnulus
cs_stimJobInterval.xsd
maxFluidRateTubing
cs_stimJobInterval.xsd
maxFluidRateCasing
cs_stimJobInterval.xsd
maxFluidRateAnnulus
cs_stimJobInterval.xsd
breakPressure
DM_STIM_TREATMENT
break_pressure
cs_stimJobInterval.xsd
averagePressure
DM_STIM_JOB
avg_treating_pressure
cs_stimJobInterval.xsd
avgCleanReturnRate
may accumulate from
lower levels
cs_stimJobInterval.xsd
avgSlurryReturnRate
may accumulate from
lower levels
cs_stimJobInterval.xsd
totalVolume
may accumulate from
lower levels
cs_stimJobInterval.xsd
maxProppantConcSurfa
ce
may accumulate from
lower levels
5000.1.7
Draft
WITSML Schema
Page 178 of 423
not imported
(calculated)
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Attribute
cs_stimJobInterval.xsd
maxProppantConcBotto
mHole
cs_stimJobInterval.xsd
avgProppantConcSurfa
ce
cs_stimJobInterval.xsd
avgProppantConcBotto
mHole
cs_stimJobInterval.xsd
proppantConcAtPerfs
cs_stimJobInterval.xsd
totalProppant
cs_stimJobInterval.xsd
totalProppantUsage
cs_stimJobInterval.xsd
proppantName
cs_stimJobInterval.xsd
totalMassUsed
cs_stimJobInterval.xsd
percentProppantPumpe
d
cs_stimJobInterval.xsd
proppantInWellbore
cs_stimJobInterval.xsd
proppantName
cs_stimJobInterval.xsd
proppantInFormation
cs_stimJobInterval.xsd
totalPerfBalls
cs_stimJobInterval.xsd
EDM Table
EDM Column
EDM Import Rule
may accumulate from
lower levels
DM_STIM_TREATMENT
prop_conc_average
DM_STIM_JOB
total_proppant_used
not imported
(calculated)
DM_STIM_FLUID_SCH
EDULE
proppant_name
not imported, complex
type, 1:n
DM_STIM_JOB
total_proppant_in_for
mation
not imported
(calculated)
totalN2
DM_STIM_TREATMENT
gas_total_n2
cs_stimJobInterval.xsd
totalCO2
DM_STIM_TREATMENT
gas_total_co2
cs_stimJobInterval.xsd
fluidName
cs_stimJobInterval.xsd
fractureGradient
DM_STIM_TREATMENT
frac_gradient
cs_stimJobInterval.xsd
finalFractGradient
cs_stimJobInterval.xsd
initialShutInPressure
DM_STIM_TREATMENT
initial_shut_in_pressur
e
cs_stimJobInterval.xsd
shutInPressure
cs_stimJobInterval.xsd
pressure
DM_STIM_TREATMENT
int_shut_in_pressure_
1,
int_shut_in_pressure2
(note spelling),
int_shut_in_pressure_
3
Import first 3 then
ignore
cs_stimJobInterval.xsd
timeAfterShutIn
DM_STIM_TREATMENT
int_shut_in_pressure1
_time, then 2 then 3
Import first 3 then
ignore
cs_stimJobInterval.xsd
screenOutPressure
cs_stimJobInterval.xsd
hhpOrderedCO2
cs_stimJobInterval.xsd
hhpOrderedFluid
cs_stimJobInterval.xsd
hhpUsedCO2
cs_stimJobInterval.xsd
hhpUsedFluid
5000.1.7
units must go to
measure 55
not imported (complex
type)
Page 179 of 423
May 2010
Draft
WITSML Schema
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Schema
WITSML Attribute
EDM Table
EDM Column
EDM Import Rule
cs_stimJobInterval.xsd
perfBallSize
DM_STIM_FLUID_SCH
EDULE
proppant_size
not imported (note formerly created stage
& fluid records)
cs_stimJobInterval.xsd
screenedOut
DM_STIM_TREATMENT
is_screened_out
WITSML values of
True, False, 0 or 1 will
be converted to Y or N
in EDM consecutively.
If this value is missing
it will be NULL in EDM.
cs_stimFlowPath.xsd
cs_stimFlowPath.xsd
pipeFrictionFactor
DM_STIM_FLOWPATH
pipe_friction_factor
cs_stimFlowPath.xsd
stimFlowPathType
DM_STIM_FLOWPATH
stim_flowpath_type
cs_stimFlowPath.xsd
stimFlowPathName
DM_STIM_FLOWPATH
stim_flowpath_name
cs_stimFlowPath.xsd
flowpathDescription
DM_STIM_FLOWPATH
flowpath_description
cs_stimFlowPath.xsd
maxTreatmentPressure
DM_STIM_FLOWPATH
max_treatment_pressu
re
cs_stimFlowPath.xsd
maxSlurryRate
DM_STIM_FLOWPATH
max_slurry_rate
cs_stimFlowPath.xsd
maxWHRate
DM_STIM_FLOWPATH
max_wh_rate
cs_stimFlowPath.xsd
maxN2StdRate
DM_STIM_FLOWPATH
max_n2_std_rate
cs_stimFlowPath.xsd
maxCO2LiquidRate
DM_STIM_FLOWPATH
max_co2_liquid_rate
cs_stimFlowPath.xsd
maxGelRate
DM_STIM_FLOWPATH
max_gel_rate
cs_stimFlowPath.xsd
maxOilRate
DM_STIM_FLOWPATH
max_oil_rate
cs_stimFlowPath.xsd
maxAcidRate
DM_STIM_FLOWPATH
max_acid_rate
cs_stimFlowPath.xsd
maxPropConc
DM_STIM_FLOWPATH
max_prop_conc
cs_stimFlowPath.xsd
maxSluryPropConc
DM_STIM_FLOWPATH
max_slurry_prop_conc
cs_stimFlowPath.xsd
avgTreatPres
DM_STIM_FLOWPATH
avg_treatment_pressu
re
cs_stimFlowPath.xsd
avgCleanRate
DM_STIM_FLOWPATH
avg_clean_rate
cs_stimFlowPath.xsd
avgSlurryRate
DM_STIM_FLOWPATH
avg_slurry_rate
cs_stimFlowPath.xsd
avgWHRate
DM_STIM_FLOWPATH
avg_wh_rate
cs_stimFlowPath.xsd
avgN2StdRate
DM_STIM_FLOWPATH
avg_n2_std_rate
cs_stimFlowPath.xsd
avgCO2LiquidRate
DM_STIM_FLOWPATH
avg_co2_std_rate
cs_stimFlowPath.xsd
avgGelRate
DM_STIM_FLOWPATH
avg_gel_rate
cs_stimFlowPath.xsd
avgOilRate
DM_STIM_FLOWPATH
avg_oil_rate
cs_stimFlowPath.xsd
avgAcidRate
DM_STIM_FLOWPATH
avg_acid_rate
cs_stimFlowPath.xsd
avgPropConc
DM_STIM_FLOWPATH
avg_prop_conc
5000.1.7
Page 180 of 423
May 2010
Draft
new
DM_STIM_FLOWBACK
record for every flow
path (new child of
DM_STIM_TREATMENT
)
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Attribute
EDM Table
EDM Column
cs_stimFlowPath.xsd
avgSlurryPropConc
DM_STIM_FLOWPATH
avg_slurry_prop_conc
cs_stimFlowPath.xsd
avgTemperature
DM_STIM_FLOWPATH
avg_temperature
cs_stimFlowPath.xsd
avgIntervalPhaseFracti
on
DM_STIM_FLOWPATH
avg_interval_phase_fr
action
cs_stimFlowPath.xsd
avgCleanQuality
DM_STIM_FLOWPATH
avg_clean_quality
cs_stimFlowPath.xsd
avgN2CleanQuality
DM_STIM_FLOWPATH
avg_n2_clean_quality
cs_stimFlowPath.xsd
avgCO2CleanQuality
DM_STIM_FLOWPATH
avg_co2_clean_quality
cs_stimFlowPath.xsd
avgHydraulicPower
DM_STIM_FLOWPATH
avg_hydraulic_power
cs_stimFlowPath.xsd
cleanVol
DM_STIM_FLOWPATH
clean_vol
cs_stimFlowPath.xsd
slurryVol
DM_STIM_FLOWPATH
slurry_vol
cs_stimFlowPath.xsd
WHVol
DM_STIM_FLOWPATH
wh_vol
cs_stimFlowPath.xsd
N2StdVol
DM_STIM_FLOWPATH
n2_std_vol
cs_stimFlowPath.xsd
CO2Mass
DM_STIM_FLOWPATH
co2_mass
cs_stimFlowPath.xsd
gelVol
DM_STIM_FLOWPATH
gel_vol
cs_stimFlowPath.xsd
oilVol
DM_STIM_FLOWPATH
oil_vol
cs_stimFlowPath.xsd
acidVol
DM_STIM_FLOWPATH
acid_vol
cs_stimFlowPath.xsd
cleanBypassVol
DM_STIM_FLOWPATH
clean_bypass_vol
cs_stimFlowPath.xsd
propMass
DM_STIM_FLOWPATH
prop_mass
cs_stimFlowPath.xsd
maxPmaxPacPres
DM_STIM_FLOWPATH
max_pmax_pac_press
ure
cs_stimFlowPath.xsd
maxPmaxWLPres
DM_STIM_FLOWPATH
max_pmax_wl_pressur
e
cs_stimFlowPath.xsd
avgPmaxPacPres
DM_STIM_FLOWPATH
avg_pmax_pac_pressu
re
cs_stimFlowPath.xsd
avgPmaxWLPres
DM_STIM_FLOWPATH
avg_pmax_wl_pressur
e
cs_stimFlowPath.xsd
SIPres5Min
DM_STIM_FLOWPATH
si_press_5_min
cs_stimFlowPath.xsd
SIPres10Min
DM_STIM_FLOWPATH
si_press_10_min
cs_stimFlowPath.xsd
SIPres15Min
DM_STIM_FLOWPATH
si_press_15_min
cs_stimFlowPath.xsd
breakDownPressure
DM_STIM_FLOWPATH
break_down_pressure
cs_stimFlowPath.xsd
percentPad
DM_STIM_FLOWPATH
percent_pad
cs_stimFlowPath.xsd
fractureGradient
DM_STIM_FLOWPATH
fracture_gradient
cs_stimFlowPath.xsd
tubingSize
DM_STIM_FLOWPATH
tubing_size
cs_stimFlowPath.xsd
tubingWeight
DM_STIM_FLOWPATH
tubing_weight
cs_stimFlowPath.xsd
casingSize
DM_STIM_FLOWPATH
casing_size
cs_stimFlowPath.xsd
casingWeight
DM_STIM_FLOWPATH
casing_weight
5000.1.7
Page 181 of 423
EDM Import Rule
Draft
WITSML Schema
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Schema
WITSML Attribute
cs_stimFlowPath.xsd
jobStage
EDM Table
EDM Column
cs_stimJobStage.xsd
EDM Import Rule
New DM_STIM_STAGE
record, child of
DM_STIM_TREATMENT
, FK link to
DM_STIM_FLOWPATH
through new
DM_STIM_FLOWPATH_
STAGE record. 
stimStageType
DM_STIM_STAGE
stage_type
cs_stimJobStage.xsd
stimStageName
DM_STIM_STAGE
stage_comments
cs_stimJobStage.xsd
stageDescription
DM_STIM_STAGE
stage_comments
Append to
stimStageName and
place in square
brackets [ ]
cs_stimJobStage.xsd
numStage
DM_STIM_STAGE
sequence_no
do not import but
generate a unique
ascending sequence
number instead
cs_stimJobStage.xsd
startTime
DM_STIM_FLUID_SCH
EDULE
time_start
Generate sequence_no
in new
DM_STIM_FLUID_SCH
EDULE record
cs_stimJobStage.xsd
endTime
DM_STIM_FLUID_SCH
EDULE
time_end
cs_stimJobStage.xsd
pumpTime
DM_STIM_STAGE_SUP
PLEMENT
pump_time
cs_stimJobStage.xsd
startRateSurfaceLiquid
DM_STIM_STAGE_SUP
PLEMENT
start_rate_surface_liqu
id
cs_stimJobStage.xsd
endRateSurfaceLiquid
DM_STIM_STAGE_SUP
PLEMENT
end_rate_surface_liqui
d
cs_stimJobStage.xsd
avgRateSurfaceLiquid
DM_STIM_FLUID_SCH
EDULE
average_fluid_rate
cs_stimJobStage.xsd
startRateSurfaceCO2
DM_STIM_STAGE_SUP
PLEMENT
start_rate_surface_co2
cs_stimJobStage.xsd
endRateSurfaceCO2
DM_STIM_STAGE_SUP
PLEMENT
end_rate_surface_co2
cs_stimJobStage.xsd
avgRateSurfaceCO2
DM_STIM_FLUID_SCH
EDULE
avg_gas_rate_co2
cs_stimJobStage.xsd
startRateSurfaceN2
DM_STIM_STAGE_SUP
PLEMENT
start_rate_surface_n2
cs_stimJobStage.xsd
endRateSurfaceN2
DM_STIM_STAGE_SUP
PLEMENT
end_rate_surface_n2
cs_stimJobStage.xsd
avgRateSurfaceN2
DM_STIM_FLUID_SCH
EDULE
avg_gas_rate_n2
5000.1.7
Page 182 of 423
Truncate to 20 if
necessary; longest
type in enumeration is
length 21
May 2010
Draft
cs_stimJobStage.xsd
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Attribute
EDM Table
EDM Column
EDM Import Rule
cs_stimJobStage.xsd
startPressureSurface
DM_STIM_FLUID_SCH
EDULE
see import rule
casing_pressure_initial
for a Casing flowpath,
tubing_pressure_initial
for a Tubing flowpath. 
Also goes to
DM_STIM_STAGE_SUP
PLEMENT.start_pressur
e_surface.
cs_stimJobStage.xsd
endPressureSurface
DM_STIM_FLUID_SCH
EDULE
see import rule
casing_pressure_final
for a Casing flowpath,
tubing_pressure_final
for a Tubing flowpath. 
Also goes to
DM_STIM_STAGE_SUP
PLEMENT.end_pressure
_surface.
cs_stimJobStage.xsd
averagePressureSurfac
e
DM_STIM_FLUID_SCH
EDULE
avg_inj_pressure
cs_stimJobStage.xsd
startPumpRateBottom
Hole
DM_STIM_STAGE_SUP
PLEMENT
start_pump_rate_botto
m_hole
cs_stimJobStage.xsd
endPumpRateBottomH
ole
DM_STIM_STAGE_SUP
PLEMENT
end_pump_rate_botto
m_hole
cs_stimJobStage.xsd
avgPumpRateBottomH
ole
DM_STIM_STAGE_SUP
PLEMENT
avg_pump_rate_botto
m_hole
cs_stimJobStage.xsd
startPressureBottomHo
le
DM_STIM_STAGE_SUP
PLEMENT
start_pressure_bottom
_hole
cs_stimJobStage.xsd
endPressureBottomHol
e
DM_STIM_STAGE_SUP
PLEMENT
end_pressure_bottom_
hole
cs_stimJobStage.xsd
averagePressureBotto
mHole
DM_STIM_STAGE_SUP
PLEMENT
average_pressure_bott
om_hole
cs_stimJobStage.xsd
startProppantConcSurf
ace
DM_STIM_FLUID_SCH
EDULE
proppant_concentratio
n_start
cs_stimJobStage.xsd
endProppantConcSurfa
ce
DM_STIM_FLUID_SCH
EDULE
proppant_concentratio
n_end
cs_stimJobStage.xsd
avgProppantConcSurfa
ce
DM_STIM_FLUID_SCH
EDULE
proppant_concentratio
n
cs_stimJobStage.xsd
startProppantConcBH
DM_STIM_STAGE_SUP
PLEMENT
start_proppant_conc_b
h
cs_stimJobStage.xsd
endProppantConcBH
DM_STIM_STAGE_SUP
PLEMENT
end_proppant_conc_bh
cs_stimJobStage.xsd
avgProppantConcBH
DM_STIM_STAGE_SUP
PLEMENT
avg_proppant_conc_bh
cs_stimJobStage.xsd
startFoamRateN2
DM_STIM_FLUID_SCH
EDULE
start_foam_rate_n2
cs_stimJobStage.xsd
endFoamRateN2
DM_STIM_FLUID_SCH
EDULE
end_foam_rate_n2
cs_stimJobStage.xsd
startFoamRateCO2
DM_STIM_FLUID_SCH
EDULE
start_foam_rate_co2
cs_stimJobStage.xsd
endFoamRateCO2
DM_STIM_FLUID_SCH
EDULE
end_foam_rate_co2
cs_stimJobStage.xsd
fluidVolClean
DM_STIM_FLUID_SCH
EDULE
fluid_volume_clean
5000.1.7
Page 183 of 423
import to EDM
Calculated Editable
field
May 2010
Draft
WITSML Schema
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Attribute
EDM Table
EDM Column
cs_stimJobStage.xsd
fluidVolDirty
DM_STIM_STAGE_SUP
PLEMENT
fluid_vol_dirty
cs_stimJobStage.xsd
fluidVolSlury
DM_STIM_FLUID_SCH
EDULE
volume_pumped
cs_stimJobStage.xsd
dirtyRateBegin
DM_STIM_FLUID_SCH
EDULE
pumping_rate_initial
cs_stimJobStage.xsd
dirtyRateEnd
DM_STIM_FLUID_SCH
EDULE
pumping_rate_final
cs_stimJobStage.xsd
proppantMassWellHead
DM_STIM_STAGE_SUP
PLEMENT
proppant_mass_well_h
ead
cs_stimJobStage.xsd
proppantMass
DM_STIM_STAGE
proppant_used
cs_stimJobStage.xsd
maxPressure
DM_STIM_STAGE_SUP
PLEMENT
max_pressure
cs_stimJobStage.xsd
maxSlurryRate
DM_STIM_STAGE_SUP
PLEMENT
max_slurry_rate
cs_stimJobStage.xsd
maxWHRate
DM_STIM_STAGE_SUP
PLEMENT
max_wh_rate
cs_stimJobStage.xsd
maxN2Rate
DM_STIM_STAGE_SUP
PLEMENT
max_n2_rate
cs_stimJobStage.xsd
maxCO2LiquidRate
DM_STIM_STAGE_SUP
PLEMENT
max_co2_liquid_rate
cs_stimJobStage.xsd
maxPropConc
DM_STIM_STAGE_SUP
PLEMENT
max_prop_conc
cs_stimJobStage.xsd
maxSlurryPropConc
DM_STIM_STAGE_SUP
PLEMENT
max_slurry_prop_conc
cs_stimJobStage.xsd
avgPropConc
DM_STIM_STAGE_SUP
PLEMENT
avg_prop_conc
cs_stimJobStage.xsd
avgSlurryPropConc
DM_STIM_STAGE_SUP
PLEMENT
avg_slurry_prop_conc
cs_stimJobStage.xsd
avgTemperature
DM_STIM_STAGE_SUP
PLEMENT
avg_temperature
cs_stimJobStage.xsd
avgInternalPhaseFracti
on
DM_STIM_STAGE_SUP
PLEMENT
avg_internal_phase_fr
action
cs_stimJobStage.xsd
avgCleanQuality
DM_STIM_STAGE_SUP
PLEMENT
avg_clean_quality
cs_stimJobStage.xsd
avgN2CleanQuality
DM_STIM_STAGE_SUP
PLEMENT
avg_n2_clean_quality
cs_stimJobStage.xsd
avgCO2CleanQuality
DM_STIM_STAGE_SUP
PLEMENT
avg_co2_clean_quality
cs_stimJobStage.xsd
avgHydraulicPower
DM_STIM_STAGE_SUP
PLEMENT
avg_hydraulic_power
cs_stimJobStage.xsd
avgCleanRate
DM_STIM_STAGE_SUP
PLEMENT
avg_clean_rate
cs_stimJobStage.xsd
avgDirtyRate
DM_STIM_STAGE_SUP
PLEMENT
avg_dirty_rate
cs_stimJobStage.xsd
avgWHRate
DM_STIM_STAGE_SUP
PLEMENT
avg_wh_rate
5000.1.7
Page 184 of 423
EDM Import Rule
import to EDM
Calculated Editable
field
Draft
WITSML Schema
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Attribute
EDM Table
EDM Column
cs_stimJobStage.xsd
avgN2Rate
DM_STIM_STAGE_SUP
PLEMENT
avg_n2_rate
cs_stimJobStage.xsd
avgCO2Rate
DM_STIM_STAGE_SUP
PLEMENT
avg_co2_rate
cs_stimJobStage.xsd
cleanVol
DM_STIM_STAGE_SUP
PLEMENT
clean_vol
cs_stimJobStage.xsd
slurryVol
DM_STIM_STAGE_SUP
PLEMENT
slurry_vol
cs_stimJobStage.xsd
wellheadVol
DM_STIM_STAGE_SUP
PLEMENT
wellhead_vol
cs_stimJobStage.xsd
maxPmaxPacPres
DM_STIM_STAGE_SUP
PLEMENT
max_pmax_pac_pres
cs_stimJobStage.xsd
maxPmaxWLPres
DM_STIM_STAGE_SUP
PLEMENT
max_pmax_wl_pres
cs_stimJobStage.xsd
maxGelRate
DM_STIM_STAGE_SUP
PLEMENT
max_gel_rate
cs_stimJobStage.xsd
maxOilRate
DM_STIM_STAGE_SUP
PLEMENT
max_oil_rate
cs_stimJobStage.xsd
maxAcidRate
DM_STIM_STAGE_SUP
PLEMENT
max_acid_rate
cs_stimJobStage.xsd
avgGelRate
DM_STIM_STAGE_SUP
PLEMENT
avg_gel_rate
cs_stimJobStage.xsd
avgOilRate
DM_STIM_STAGE_SUP
PLEMENT
avg_oil_rate
cs_stimJobStage.xsd
avgAcidRate
DM_STIM_STAGE_SUP
PLEMENT
avg_acid_rate
cs_stimJobStage.xsd
gelVolume
DM_STIM_STAGE_SUP
PLEMENT
gel_volume
cs_stimJobStage.xsd
oilVolume
DM_STIM_STAGE_SUP
PLEMENT
oil_volume
cs_stimJobStage.xsd
acidVolume
DM_STIM_STAGE_SUP
PLEMENT
acid_volume
cs_stimJobStage.xsd
cleanBypassVolume
DM_STIM_STAGE_SUP
PLEMENT
clean_bypass_volume
cs_stimJobStage.xsd
frictionFactor
DM_STIM_STAGE
friction_casing
cs_stimJobStage.xsd
stageFluid
cs_stimFluid.xsd
When the cs_stimFluid
object is found in the
file, create a new
DM_STIM_FLUID
record with a unique
sequence number. Put
its key into the current
DM_STIM_FLUID_SCH
cs_stimFluid.xsd
nameFluid
DM_STIM_FLUID
fluid_name
cs_stimFluid.xsd
fluidVol
DM_STIM_FLUID
volume_pumped
cs_stimFluid.xsd
waterSource
5000.1.7
EDM Import Rule
Draft
WITSML Schema
Page 185 of 423
do not import. Create a
new schedule record.
Link to the current fluid
record (fill in the key).
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Schema
WITSML Attribute
cs_stimFluid.xsd
stimAdditive
cs_stimFluid.xsd
stimProppant
EDM Table
EDM Column
cs_stimAdditive.xsd
EDM Import Rule
New
DM_STIM_FLUID_ADD
record
nameAdd
DM_STIM_FLUID_ADD
additive_name
truncate to 25 if
necessary; schema
allows 64
cs_stimAdditive.xsd
typeAdd
DM_STIM_FLUID_ADD
additive_type
truncate to 32 if
necessary
cs_stimAdditive.xsd
volume
DM_STIM_FLUID_ADD
amount_used
import without unit
conversion and add
uom (e. g. "galUS") to
DM_STIM_FLUID_ADD.
additive_unit
truncate to 32 if
necessary
cs_stimProppant.xsd
nameProppant
DM_STIM_FLUID_SCH
EDULE
proppant_name
truncate to 16 if
necessary; schema
allows 64
cs_stimProppant.xsd
typeProppant
DM_STIM_FLUID_SCH
EDULE
proppant_name
Append the type to the
name inside square
brackets. If the result
exceeds 16 characters,
truncate to 16.
cs_stimProppant.xsd
weight
DM_STIM_FLUID_SCH
EDULE
proppant_used
cs_stimProppant.xsd
sieveSize
DM_STIM_FLUID_SCH
EDULE
proppant_size
cs_stimProppant.xsd
cs_stimPDatSession.xs
d
New
DM_STIM_PUMPING_D
IAG under
DM_STIM_TREATMENT
cs_stimPDatSession.xs
d
sessionName
DM_STIM_PUMPING_D
IAG
session_name
cs_stimPDatSession.xs
d
description
DM_STIM_PUMPING_D
IAG
description
cs_stimPDatSession.xs
d
sessionNumber
DM_STIM_PUMPING_D
IAG
session_number
cs_stimPDatSession.xs
d
pumpOnTime
DM_STIM_PUMPING_D
IAG
pump_on_time
cs_stimPDatSession.xs
d
pumpOffTime
DM_STIM_PUMPING_D
IAG
pump_off_time
cs_stimPDatSession.xs
d
shutInTime
DM_STIM_PUMPING_D
IAG
shutin_time
cs_stimPDatSession.xs
d
fracCloseTime
DM_STIM_PUMPING_D
IAG
frac_close_time
cs_stimPDatSession.xs
d
pumpDuration
DM_STIM_PUMPING_D
IAG
pump_duration
cs_stimPDatSession.xs
d
avgBottomHoleTreatm
entPressure
DM_STIM_PUMPING_D
IAG
avg_bh_treatment_pre
ssure
5000.1.7
Page 186 of 423
May 2010
Draft
cs_stimAdditive.xsd
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Attribute
EDM Table
EDM Column
cs_stimPDatSession.xs
d
BhHydrostaticPressure
DM_STIM_PUMPING_D
IAG
bh_hydrostatic_pressu
re
cs_stimPDatSession.xs
d
bubblePointPressure
DM_STIM_PUMPING_D
IAG
bubble_point_pressure
cs_stimPDatSession.xs
d
fractureClosePressure
DM_STIM_PUMPING_D
IAG
fracture_close_pressur
e
cs_stimPDatSession.xs
d
frictionPressure
DM_STIM_PUMPING_D
IAG
friction_pressure
cs_stimPDatSession.xs
d
initialSIPressure
DM_STIM_PUMPING_D
IAG
initial_si_pressure
cs_stimPDatSession.xs
d
porePressure
DM_STIM_PUMPING_D
IAG
pore_pressure
cs_stimPDatSession.xs
d
avgBHTreatmentRate
DM_STIM_PUMPING_D
IAG
avg_bh_treatment_rat
e
cs_stimPDatSession.xs
d
fluidDensity
DM_STIM_PUMPING_D
IAG
fluid_density
cs_stimPDatSession.xs
d
cleanVolume
DM_STIM_PUMPING_D
IAG
clean_volume
cs_stimPDatSession.xs
d
wellBoreVolume
DM_STIM_PUMPING_D
IAG
wellbore_volume
cs_stimPDatSession.xs
d
surfaceMD
DM_STIM_PUMPING_D
IAG
surface_md
cs_stimPDatSession.xs
d
bottomHoleMD
DM_STIM_PUMPING_D
IAG
bottom_hole_md
cs_stimPDatSession.xs
d
midPerforationsMD
DM_STIM_PUMPING_D
IAG
mid_perforations_md
cs_stimPDatSession.xs
d
midPerforationsTVD
DM_STIM_PUMPING_D
IAG
mid_perforations_tvd
cs_stimPDatSession.xs
d
surfaceTemperature
DM_STIM_PUMPING_D
IAG
surface_temperature
cs_stimPDatSession.xs
d
bottomHoleTemperatur
e
DM_STIM_PUMPING_D
IAG
bottom_hole_temperat
ure
cs_stimPDatSession.xs
d
surfaceFluidTemperatu
re
DM_STIM_PUMPING_D
IAG
surface_fluid_temperat
ure
cs_stimPDatSession.xs
d
fluidCompressibility
DM_STIM_PUMPING_D
IAG
fluid_compressibility
cs_stimPDatSession.xs
d
resevoirTotalCompressi
bility
DM_STIM_PUMPING_D
IAG
res_total_compressibili
ty
cs_stimPDatSession.xs
d
fluidNPrimeFactor
DM_STIM_PUMPING_D
IAG
fluid_nprime_factor
cs_stimPDatSession.xs
d
fluidKPrimeFactor
DM_STIM_PUMPING_D
IAG
fluid_kprime_factor
cs_stimPDatSession.xs
d
fluidSpecificHeat
DM_STIM_PUMPING_D
IAG
fluid_specific_heat
cs_stimPDatSession.xs
d
fluidThermalConductivi
ty
DM_STIM_PUMPING_D
IAG
fluid_thermal_conducti
vity
cs_stimPDatSession.xs
d
fluidThermalExpansion
Coefficient
DM_STIM_PUMPING_D
IAG
fluid_thermal_expansio
n_coef
5000.1.7
Page 187 of 423
EDM Import Rule
Draft
WITSML Schema
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Schema
WITSML Attribute
EDM Table
EDM Column
cs_stimPDatSession.xs
d
fluidEfficiency
DM_STIM_PUMPING_D
IAG
fluid_efficiency
cs_stimPDatSession.xs
d
foamQuality
DM_STIM_PUMPING_D
IAG
foam_quality
cs_stimPDatSession.xs
d
percentPad
DM_STIM_PUMPING_D
IAG
percent_pad
cs_stimPDatSession.xs
d
stageNumber
DM_STIM_PUMPING_D
IAG
stage_number
cs_stimPDatSession.xs
d
temperatureCorrelated
Calculations
DM_STIM_PUMPING_D
IAG
is_temp_correlated_cal
c
New
DM_STIM_STEP_TEST
under current
DM_STIM_PUMPING_D
IAG
cs_stimStepTest.xsd
pressure
DM_STIM_STEP_TEST
pressure
cs_stimStepTest.xsd
bottomHoleRate
DM_STIM_STEP_TEST
bottom_hole_rate
cs_stimStepTest.xsd
fractureExtensionPress
ure
DM_STIM_STEP_TEST
fracture_extension_pre
ssure
cs_stimReservoirInterv
al.xsd
New
DM_STIM_RES_INTER
VAL under current
DM_STIM_TREATMENT
cs_stimReservoirInterv
al.xsd
lithTopMD
DM_STIM_RES_INTER
VAL
lith_top_md
cs_stimReservoirInterv
al.xsd
lithBottomMD
DM_STIM_RES_INTER
VAL
lith_bottom_md
cs_stimReservoirInterv
al.xsd
lithFormationPermeabil
ity
DM_STIM_RES_INTER
VAL
lith_formation_permea
bility
cs_stimReservoirInterv
al.xsd
lithYoungsModulus
DM_STIM_RES_INTER
VAL
lith_youngs_modulus
cs_stimReservoirInterv
al.xsd
lithPorePressure
DM_STIM_RES_INTER
VAL
lith_pore_pressure
cs_stimReservoirInterv
al.xsd
lithNetPayThickness
DM_STIM_RES_INTER
VAL
lith_net_pay_thickness
cs_stimReservoirInterv
al.xsd
lithName
DM_STIM_RES_INTER
VAL
lith_name
cs_stimReservoirInterv
al.xsd
netPayTopMD
DM_STIM_RES_INTER
VAL
net_pay_top_md
cs_stimReservoirInterv
al.xsd
netPayBottomMD
DM_STIM_RES_INTER
VAL
net_pay_bottom_md
cs_stimReservoirInterv
al.xsd
netPayGrossThickness
DM_STIM_RES_INTER
VAL
net_pay_gross_thickne
ss
cs_stimReservoirInterv
al.xsd
netPayNetPayThicknes
s
DM_STIM_RES_INTER
VAL
net_pay_net_pay_thick
ness
cs_stimReservoirInterv
al.xsd
netPayPorePressure
DM_STIM_RES_INTER
VAL
net_pay_pore_pressur
e
cs_stimReservoirInterv
al.xsd
netPayFluidCompressib
ility
DM_STIM_RES_INTER
VAL
net_pay_fluid_compres
sibility
5000.1.7
Page 188 of 423
May 2010
Draft
cs_stimStepTest.xsd
EDM Import Rule
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Attribute
EDM Table
EDM Column
cs_stimReservoirInterv
al.xsd
netPayFluidViscosity
DM_STIM_RES_INTER
VAL
net_pay_fluid_viscosity
cs_stimReservoirInterv
al.xsd
netPayName
DM_STIM_RES_INTER
VAL
net_pay_name
cs_stimReservoirInterv
al.xsd
netPayFormationPerme
ability
DM_STIM_RES_INTER
VAL
net_pay_formation_pe
rmeability
cs_stimReservoirInterv
al.xsd
lithPoissonsRatio
DM_STIM_RES_INTER
VAL
lith_poissons_ratio
cs_stimReservoirInterv
al.xsd
netPayFormationPorosi
ty
DM_STIM_RES_INTER
VAL
net_pay_formation_po
rosity
cs_stimReservoirInterv
al.xsd
lithFormationPorosity
DM_STIM_RES_INTER
VAL
lith_formation_porosity
cs_stimFetTest.xsd
New
DM_STIM_FET_TEST
under current
DM_STIM_PUMP_DIAG
cs_stimFetTest.xsd
startTime
DM_STIM_FET_TEST
start_time
cs_stimFetTest.xsd
endTime
DM_STIM_FET_TEST
end_time
cs_stimFetTest.xsd
endPDLDuration
DM_STIM_FET_TEST
end_pdl_duration
cs_stimFetTest.xsd
fractureClosingDuratio
n
DM_STIM_FET_TEST
fracture_closing_durati
on
cs_stimFetTest.xsd
fractureClosingPressur
e
DM_STIM_FET_TEST
fracture_closing_press
ure
cs_stimFetTest.xsd
fractureExtensionPress
ure
DM_STIM_FET_TEST
fracture_extension_pre
ssure
cs_stimFetTest.xsd
netPressure
DM_STIM_FET_TEST
net_pressure
cs_stimFetTest.xsd
porePressure
DM_STIM_FET_TEST
pore_pressure
cs_stimFetTest.xsd
pseudoRadialPressure
DM_STIM_FET_TEST
pseudo_radial_pressur
e
cs_stimFetTest.xsd
fractureLength
DM_STIM_FET_TEST
fracture_length
cs_stimFetTest.xsd
fractureWidth
DM_STIM_FET_TEST
fracture_width
cs_stimFetTest.xsd
fluidEfficiency
DM_STIM_FET_TEST
fluid_efficiency
cs_stimFetTest.xsd
pDLCoef
DM_STIM_FET_TEST
pdl_coef
cs_stimFetTest.xsd
residualPermeability
DM_STIM_FET_TEST
residual_permeability
cs_stimPumpFlowBack
Test.xsd
New
DM_STIM_PUMP_FB_T
EST under current
DM_STIM_PUMP_DIAG
cs_stimPumpFlowBack
Test.xsd
fractureCloseDuration
DM_STIM_PUMP_FB_T
EST
fracture_close_duratio
n
cs_stimPumpFlowBack
Test.xsd
fractureClosePressure
DM_STIM_PUMP_FB_T
EST
fracture_close_pressur
e
•
5000.1.7
EDM Import Rule
WITSML to EDM Unit Mappings
Page 189 of 423
May 2010
Draft
WITSML Schema
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
The following table outlines the units used when mapping data from the
WITSML 1.3.1 XML file generated in the Halliburton SUMMIT™ application to
the EDM™ Database
WITSML Unit Type
WITSML Unit of
Measure
EDM ID
EDM Label
EDM Type
1/psi
93
1/psi
Type 19, fluid compressibility
1/Pa
90
1/Pa
Type 19, fluid compressibility
1/bar
358
1/bar
Type 19, fluid compressibility
1/kPa
91
1/kPa
Type 19, fluid compressibility
51
kg/m³
Type 14, density
dAPI
62
deg API
Type 14, density
g/cm3
49
g/cc
Type 14, density
555
g/L
Type 14, density
58
kg/L
Type 14, density
lbm/bbl
50
lbm/bbl
Type 14, density
lbm/ft3
52
lbm/ft³
Type 14, density
compressibilityUom
1/upsi
densityMeasure
densityUom
kg/m3
10Mg/m3
g/dm3
g/galUK
g/galUS
g/L
g/m3
grain/ft3
grain/galUS
grain/100ft3
kg/dm3
kg/L
Mg/m3
lbm/10bbl
lbm/galUK
lbm/1000galUK
5000.1.7
Page 190 of 423
May 2010
Draft
1/pPa
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Unit Type
WITSML Unit of
Measure
EDM ID
EDM Label
EDM Type
lbm/galUS
57
ppg
Type 14, density
lbm/1000galUS
463
lbm/1000gal
Type 14, density
61
mg/L
Type 14, density
154
%
Type 29, dimensionless
Pa.s
254
Pa*s
Type 48, viscosity
cP
256
cp
Type 48, viscosity
259
mPa*s
Type 48, viscosity
lbm/in3
lbm/Mbbl
mg/dm3
mg/galUS
mg/L
Draft
mg/m3
ug/cm3
dimensionlessUom
Euc
%
cEuc
mEuc
nEuc
uEuc
dynamicViscosityMeasure
dynamicViscosityUom
P
psi.s
dyne.s/cm2
kgf.s/m2
lbf.s/ft2
lbf.s/in2
mPa.s
N.s/m2
forcePerVolumeUom
N/m3
atm/100m
5000.1.7
Page 191 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Unit Type
WITSML Unit of
Measure
EDM ID
EDM Label
EDM Type
174
bar/m
Type 33, pressure gradient
kPa/100m
381
kPa/100m
Type 70, frictional loss
kPa/m
168
kPa/m
Type 33, pressure gradient
167
psi/ft
Type 33, pressure gradient
54
psi/kft
Type 14, density
121
m
Type 24, length
127
cm
Type 24, length
122
ft
Type 24, length
atm/m
bar/km
bar/m
GPa/cm
lbf/ft3
Draft
lbf/galUS
MPa/m
psi/ft
psi/100ft
psi/kft
psi/m
Pa/m
atm/ft
lengthMeasure
lengthUom
m
angstrom
chBnA
chBnB
chCla
chSe
chUS
cm
dm
fathom
fm
ft
ftBnA
ftBnB
5000.1.7
Page 192 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Unit Type
WITSML Unit of
Measure
EDM ID
EDM Label
EDM Type
124
in
Type 24, length
in/16
126
16th"
Type 24, length
in/32
120
32nd"
Type 24, length
in/64
123
64th"
Type 24, length
inUS
124
in
Type 24, length
km
303
km
Type 24, length
304
mi
Type 24, length
128
mm
Type 24, length
nautmi
462
nM
Type 24, length
nm
462
nM
Type 24, length
ftBr(65)
ftCla
ftGC
ftInd
ftInd(37)
ftInd(62)
ftInd(75)
Draft
ftMA
ftSe
ftUS
in
in/10
lkBnA
lkBnB
lkCla
lkSe
lkUS
mGer
mi
mil
miUS
mm
Mm
pm
5000.1.7
Page 193 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Unit Type
WITSML Unit of
Measure
EDM ID
EDM Label
EDM Type
um
125
µm
Type 24, length
yd
340
yard
Type 24, length
135
kg
Type 25, mass
131
gram
Type 25, mass
klbm
132
klbm
Type 25, mass
lbm
136
lbm
Type 25, mass
sack94
315
94lb sacks
Type 25, mass
t
130
ton
Type 25, mass
ydBnA
ydBnB
ydCla
ydIm
ydInd
Draft
ydInd(37)
ydInd(62)
ydInd(75)
ydSe
massMeasure
massUom
kg
ag
ct
cwtUK
cwtUS
g
grain
Mg
mg
oz(av)
oz(troy)
ozm
tonUK
tonUS
5000.1.7
Page 194 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Unit Type
WITSML Unit of
Measure
EDM ID
EDM Label
EDM Type
139
kg/m
Type 26, mass per distance
138
lbm/ft
Type 26, mass per distance
kg.m/cm2
357
kg/cm²m
Type 14, density
PercentUom
154
%
Type 29, dimensionless
D
63
darcy
Type 15, effective permeability
mD
65
md
Type 15, effective permeability
W
159
Watt
Type 31, power
hhp
225
MJ
Type 44, ton-mile
hp
160
hp
Type 31, power
158
kW
Type 31, power
ug
massPerLengthMeasure
massPerLengthUom
kg/m
klbm/in
lbm/ft
Mg/in
Draft
permeabilityMeasure
permeabilityUom
powerMeasure
powerUom
ch
CV
ehp
GW
kcal/h
kW
MJ/a
MW
mW
nW
ton of refrig
TW
uW
5000.1.7
Page 195 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Unit Type
WITSML Unit of
Measure
EDM ID
EDM Label
EDM Type
Pa
190
Pa
Type 34, pressure
atm
367
atm
Type 34, pressure
bar
186
bar
Type 34, pressure
179
GPa
Type 34, pressure
191
inH2O
Type 34, pressure
177
in-Hg
Type 34, pressure
182
kgf/cm²
Type 34, pressure
kPa
188
kPa
Type 34, pressure
kpsi
189
ksi
Type 34, pressure
187
lbf/100ft²
Type 34, pressure
mbar
184
mbar
Type 34, pressure
mmHg(0C)
178
mm-Hg
Type 34, pressure
mPa
425
MPa
Type 74, pressure change
MPa
181
MPa
Type 34, pressure
Mpsi
180
Mpsi
Type 34, pressure
pressureMeasure
pressureUom
at
cmH2O(4degC)
GPa
Draft
dyne/cm2
hbar
inH2O(39.2F)
inH2O(60F)
inHg(32F)
inHg(60F)
kgf/cm2
kgf/mm2
kN/m2
lbf/ft2
lbf/100ft2
lbf/in2
N/m2
N/mm2
Pa(g)
pPa
5000.1.7
Page 196 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Unit Type
WITSML Unit of
Measure
EDM ID
EDM Label
EDM Type
psi
185
psi
Type 34, pressure
370
psig
Type 34, pressure
359
E-06/bar
Type 19, fluid compressibility
362
E-06/psi
Type 19, fluid compressibility
J/kg.K
331
joule/gK
Type 63, specific heat capacity
Btu/lbm.degF
333
BTU/lbm°F
Type 63, specific heat capacity
334
kcal/kg°C
Type 63, specific heat capacity
373
kW-hr/kg-°C
Type 63, specific heat capacity
335
BTU/hft°F
Type 64, thermal conductivity
K
429
K
Type 75, temperature change
degC
212
°C
Type 41, temperature
degF
213
°F
Type 41, temperature
degR
376
°R
Type 41, temperature
psia
psig
tonfUS/ft2
tonfUS/in2
torr
ubar
Draft
umHg(0C)
uPa
upsi
specificHeatCapacityMeasure
specificHeatCapacityUom
Btu/lbm.degR
cal/g.K
J/g.K
kcal/kg.degC
kJ/kg.K
kW.h/kg.degC
thermalConductivityUom
W/m.K
Btu/hr.ft.degF
cal/h.cm.degC
kcal/h.m.degC
cal/s.cm.degC
thermodynamicTemperatureMeasure
thermodynamicTemperatureUom
5000.1.7
Page 197 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Unit Type
WITSML Unit of
Measure
EDM ID
EDM Label
EDM Type
s
215
sec
Type 42, time
218
days
Type 42, time
214
hr
Type 42, time
min
216
min
Type 42, time
ms
47
mS
Known issues (type 12), do not
use
248
m/s
Type 47, velocity
ft/d
251
ft/day
Type 47, velocity
ft/h
246
ft/hr
Type 47, velocity
ft/min
249
ft/min
Type 47, velocity
250
ft/s
Type 47, velocity
timeMeasure
timeUom
a
cs
d
Ga
Draft
h
100s
Ma
ms/2
ns
ps
us
wk
100ka
velocityMeasure
velocityUom
m/s
cm/a
cm/s
dm/s
ft/ms
ft/s
ft/us
in/a
5000.1.7
Page 198 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Unit Type
WITSML Unit of
Measure
EDM ID
EDM Label
EDM Type
241
kft/hr
Type 47, velocity
252
km/hr
Type 47, velocity
knot
244
knots
Type 47, velocity
m/d
242
m/day
Type 47, velocity
m/h
245
m/hr
Type 47, velocity
m/min
247
m/min
Type 47, velocity
243
mph
Type 47, velocity
m3/s
70
m³/s
Type 16, flow
bbl/d
66
bbl/D
Type 16, flow
bbl/hr
453
bbl/hr
Type 16, flow
bbl/min
80
bbl/min
Type 16, flow
cm3/30min
455
cc/30min
Type 16, flow
68
ft³/D
Type 16, flow
78
ft³/min
Type 16, flow
in/min
in/s
kft/h
kft/s
km/h
km/s
Draft
m/ms
mi/h
mil/yr
mm/a
mm/s
nm/s
um/s
volumeFlowRateMeasure
volumeFlowRateUom
cm3/h
cm3/min
cm3/s
dm3/s
ft3/d
ft3/h
ft3/min
5000.1.7
Page 199 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Unit Type
WITSML Unit of
Measure
EDM ID
EDM Label
EDM Type
ft3/s
77
ft³/s
Type 16, flow
75
gpm
Type 16, flow
79
L/min
Type 16, flow
m3/d
72
m³/D
Type 16, flow
m3/h
73
m³/hr
Type 16, flow
287
m³
Type 53, volume
285
bbl
Type 53, volume
cm3
292
cc
Type 53, volume
dm3
492
dm³
Type 53, volume
284
ft³
Type 53, volume
galUK/d
galUK/hr
galUK/min
galUS/d
galUS/hr
galUS/min
Draft
kbbl/d
1000ft3/d
1000m3/d
1000m3/h
L/h
L/min
L/s
m3/min
Mbbl/d
M(ft3)/d
M(m3)/d
volumeMeasure
volumeUom
m3
acre.ft
bbl
bcf
flozUK
flozUS
ft3
5000.1.7
Page 200 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Unit Type
WITSML Unit of
Measure
EDM ID
EDM Label
EDM Type
286
gal
Type 53, volume
288
in³
Type 53, volume
291
L
Type 53, volume
283
mL
Type 53, volume
289
mm³
Type 53, volume
154
%
Type 29, dimensionless
39
ppm
Type 10, concentration
galUK
galUS
ha.m
hL
in3
1000ft3
km3
Draft
L
Mbbl
Mcf
M(ft3)
mi3
mL
M(m3)
mm3
MMbbl
ptUK
ptUS
qtUK
qtUS
tcf
um2.m
yd3
volumePerVolumeMeasure
volumePerVolumeUom
Euc
%
permil
ppdk
ppk
ppm
5000.1.7
Page 201 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Unit Type
WITSML Unit of
Measure
EDM ID
EDM Label
EDM Type
477
bbl/bbl
Type 61, liquid concentration
(vol/vol)
ft3/bbl
310
scf/bbl
Type 60, volume ratio
ft3/ft3
321
ft³/ft³
Type 61, liquid concentration
(vol/vol)
323
L/m³
Type 61, liquid concentration
(vol/vol)
396
m³/m³
Type 60, volume ratio
38
mL/mL
Type 10, concentration
bbl/acre.ft
bbl/bbl
bbl/ft3
bbl/100bbl
bbl/k(ft3)
bbl/M(ft3)
Draft
cm3/cm3
cm3/m3
dm3/m3
galUS/kgalUS
galUK/kgalUK
galUK/ft3
galUK/Mbbl
galUS/bbl
galUS/10bbl
galUS/ft3
galUS/Mbbl
1000ft3/bbl
ksm3/sm3
L/10bbl
L/m3
m3/ha.m
m3/m3
M(ft3)/acre.ft
mL/galUK
mL/galUS
mL/mL
5000.1.7
Page 202 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WITSML Unit Type
WITSML Unit of
Measure
EDM ID
EDM Label
EDM Type
473
Mscf/bbl
Type 60, volume ratio
MMbbl/acre.ft
MMscf60/stb60
Mscf60/stb60
ptUK/Mbbl
ptUS/10bbl
pu
scm15/stb60
Draft
sm3/ksm3
sm3/sm3
stb60/MMscf60
stb60/MMscm15
stb60/Mscf60
stb60/Mscm15
stb60/scm15
Release 5000.1.3
•
New platforms are supported.
•
Mobile Checkout licensing feature libraries were added.
Release 5000.1.2
The 5000.1.2 release is an incremental update of OpenWells software. The primary
focus of this update has been to enhance the user experience and to expedite user
workflows. This has been accomplished through the addition of a number of features
including:
•
Stimulation Report
— Treatments area in the Stimulation Report - The Treatments area allows users
to record multiple treatment intervals in one Stimulation Report.
— WYSIWYG - The Stimulation report now comes with a WYSIWYG (What You
See Is What You Get) data entry form.
— Volume Pumped calculation - The Volume Pumped calculation has a new
System Setting to allow administrator to change how this field is calculated. 
5000.1.7
Page 203 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
Batch Printing

Batch printing has been improved to help to free up the users time so they can
concentrate on other important aspects of their job. Output Reports can now:
—
—
—
—
be printed for multiple Projects, Sites, Wells, Wellbores and Events,
be collated into one print job,
be saved to one or multiple PDF files,
have sections included/removed during the print job.
•
Improved Default Security
Changes to the Administration tokens allow Companies to delegate the
Administration role among a number of different users.
Stimulations Report
The Stimulation Report has a number of improvements and additions to better
enable users to enter stimulation jobs in a manner that better reflects the actual
process of running a stimulation job and improves on the ease of use of the report.
•
Treatment Intervals
A Treatments section has been added to the form, to enable users to enter
multiple Treatment Intervals for each Stimulation Job. This will help to alleviate
the creation of multiple Stimulation reports for one Stimulation Job.
5000.1.7
Page 204 of 423
May 2010
Draft

In addition, once a Batch print job has been set up, the application can be set to
remember it for the next time the Print Wizard is opened.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 1: New Stimulation Treatments section
•
WYSIWYG (What You See is What You Get)
A WYSIWYG form has been added for the Stimulations report. This form is
meant to simplify data entry and allow rig users to enter data on a form that is
similar to the spreadsheet generally used in the field.
5000.1.7
Page 205 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 2: Upper section of the Stimulation WYWIWYG form
The WYSIWYG form also has an area that shows Rollup data. This area is color
coordinated to show users which fields are used in the rollup.
Figure 3: Mid section of the Stimulation WYWIWYG form. The fields used in the calculations are color coordinated within the rollup area
5000.1.7
Page 206 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
The WYSIWYG form can be configured to automatically add a specified
number of Fluids and Treatments and schedule Steps in the form when it is
created.
The number of fluids, treatments and subsequent steps can be customized by
modifying the StimulationLayout.xml WYSIWYG file and importing the modified
file as a custom WYSIWYG for the Stimulation report. This is done through the
EDM Administration Utility (see the online help system for detailed instructions).
By default, the WYSIWYG that ships with the application defines one Fluid and
one Treatment that includes a multiple step schedule encompassing a PAD, a
FET, Several Pad-Laden stages and a FLUSH.
Draft
Figure 4: Lower section of the Stimulation WYWIWYG form. This screenshot shows a
form that has been configured to automatically create two Treatments when the report
was created along with a pre-defined list of Steps.
•
Volume Pumped Calculation
A new system setting, “StimTreatmentVolumeMethod”, has been added that
defines the calculation method of the Volume Pumped in the Stimulation report
as follows:
5000.1.7
Page 207 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
— When set to “Default”, Volume Pumped is calculated as the sum of the
volumes recorded in the Volume Pad, Volume Body, and Volume
Afterflush.
— When set to “VolumePumpedRollup”, Volume Pumped is calculated as
the sum of the Clean Stage column in the WYSIWYG form's Step
spreadsheet.
Batch Printing has been implemented in the Print Wizard, accessed from the File
> Print Wizard command or from the
toolbar button.
Printing Reports from Multiple Projects, Sites, Wells, Wellbores and Events
From the Print Wizard, a users can find a Well using the
button and
select the appropriate Wellbore and Event. The user can then select the reports to
be printed and move them into the Reports selected area. Once all the reports have
been selected, the users can change the Well, Wellbore and/or Event to add more
reports to be printed.
Remember the List of Selected Reports
The Remember Selected Reports checkbox causes the application to remember
the list of selected reports. This enables the user to come back to the Print Wizard
the next day and print the same list of Reports for the current day.
5000.1.7
Page 208 of 423
May 2010
Draft
Batch Printing
The process for printing multiple Output Reports in the OpenWells® application
has been streamlined in this release. Output Reports can now be printed for
multiple Projects, Sites, Wells, Wellbores and Events and collated into one print
job. Reports can be saved to one or multiple PDF files and sections can be
removed during the print job. In addition, once the print job has been set up, the
application can be set to remember it the next time the Print Wizard is opened.
Each aspect of batch printing helps to free up the users time allowing them to take
care of other important aspects of their job.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 5: Print Wizard showing the “remembered” Output Reports, only the date
changes
Print to PDF
Once the Output Reports have been selected, the user can choose to send these
reports to a printer or exported to a PDF file. When exporting to a PDF file you have
the choice to save all of the reports to one PDF file or create a PDF file for each
individual report. The individual PDF files will be saved to the same folder.
5000.1.7
Page 209 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Define Sections to be Printed
Whether sending the Output Reports to a printer or saving them to a PDF file, users
can choose the sections of each report to be included in the Output Report. In
addition, users can choose to include a Cover Page and Table of Contents for the
report. To send multiple reports at one time without any intervention select the Hide
report options dialog checkbox. During batch printing, the most recent user choices
regarding sections will be honored. The user can set up choices by individually
printing a report via Print or Print Preview. If no choices have been made the
defaults (print all sections) will be used.
5000.1.7
Page 210 of 423
May 2010
Draft
Figure 6: Export to PDF allows you to merge the reports into one PDF file
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 7: Report Options appears for each report; user can select sections that will
appear in the PDF or Printed version. The Hide report options dialog checkbox can
also be used to skip the Report Options dialog.
Improved Default Security
Improvements have been made to the EDM Security model to allow EDM
Administrators to control who has access to the different areas of the EDM
Administration Utility. This helps to alleviate the possibility of unintended changes
within the configuration on a potential daily basis.
The Admin.start token controls which users area able to launch the EDM
Administration Utility application. The Admin.Security.edit token now controls
which uses are able to grant and revoke access to the various EDM Administrators.
These administrators can grant or revoke access to the various parts of the EDM
Administration Utility using the following list of tokens.
Token
Description
Admin.CarryOver.edit
Controls access to the OpenWells Carryover area
Admin.DataValidation.edit
Controls access to the OpenWells Data Validation area
Admin.JobTypes.edit
Controls access to the OpenWells Job Types area
Admin.LayoutManager.edit
Controls access to the OpenWells Layout Manager area
Admin.OpenwireConfig.edit
Controls access to the OpenWire Configuration area
Admin.OutputReports.edit
Controls access to the Output Reports area
5000.1.7
Page 211 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
Admin.OutputReports.Landmark.e
dit
Controls access to the Landmark shipped Output Reports
area
Admin.PreviewPanes.edit
Controls access to the OpenWells Preview Panes area
Admin.ReportTypes.edit
Controls access to the OpenWells Report Types area
Admin.SAM.edit
Controls access to the Simultaneous Activity Monitor area
Admin.ShortcutBars.edit
Controls access to the OpenWells Shortcut Bars area
Admin.StatusColors.edit
Controls access to the OpenWells Status Colors area
Admin.SystemLookups.edit
Controls access to the System Lookups area
Admin.SystemSettings.edit
Controls access to the System Settings area
Draft
Token
Release 5000.1.1
WELLCAT was added to the EDT suite of applications for the first time in the 5000.1.1
release. Also, some Common Well Explorer enhancements were made. (See EDT™
Software for details). This update release improves the import/export and sharing of
Grades, Pipes/Connections between StressCheck and WELLCAT, improves the
integration between StressCheck and WELLCAT, and repairs critical defects affecting
key StressCheck and WELLCAT application functions. There were no additional
enhancements for the OpenWells software.
Release 5000.1.0
The 5000.1 release of Engineer’s Desktop supports the Microsoft Vista operating
system, has new LAM (FLEXnet Publisher) licensing—including the Mobile Checkout
utility which gives you the ability to “borrow” a license for offsite work—and contains
some critical bug fixes.
The following enhancements were added to the OpenWire 5000.1 release. In addition,
features added in 2003.22, which were not included in the 5000.0 release are now
available in this 5000.1 release.
The primary focus of this release has been to enhance the user experience and to
expedite user workflows. This has been accomplished through the addition of a
number of features including:
•
Wizards for common workflows,
— Create a Well
— Create a Wellbore
— Create an Event
5000.1.7
Page 212 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
— Create a Rig
— Create a Daily Operations report
— Create a Report
“Today’s Wells” interactive graphic
•
Graphical Rig Equipment Editor
•
Inherent Rig Operations and Equipment entry
•
Improved Hole Sections data entry
•
Integration between the Engineering Hole Plans and Hole Sections area of the
OpenWells Well Planning Report,
•
Sub Assembly support
•
Output Reporting has been enhanced in thee following areas:
— Allow for inclusion of COMPASS Plots and Wall Plot Composer Plots within the
OpenWells output reports.
— Reformat several of the reports to look more technical and cleaner (e.g. Casing,
Cementing)
Wizard Toolbar
OpenWells offers a number of Wizards that enable you create, edit and view data,
without having to navigate through the Well Explorer tree. These Wizards are
accessed from the main application window toolbar. The toolbar can be toggled off
and on using the View > Wizard Bar command. A check mark appears next to the
menu item when the Status Bar is visible.
Figure 1: Wizard Toolbar
The Wizards available in the Wizard toolbar include the following:
•
Create Well - create a new Well and configure the Well Datum
•
Create Wellbore - create a new Wellbore
•
Create Event - create a new Event
•
Create Rig - create a new Rig
5000.1.7
Page 213 of 423
May 2010
Draft
•
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
Edit Rig - edit a Rig using the new Rig Equipment Editor (For more information
see Rig Equipment Editor on page 217.)
•
Create Daily Report - create a new Daily Operations report, associate a Rig and
create an AFE. The feature is discussed further in relation to Rig Operations
Association on page 225.
•
Create Report - create any one of the available OpenWells reports
•
Today’s Wells - determine the accuracy and completeness of your Well(s). This
feature is discussed further below.
Type names here
and
they are created here
Figure 2: Manually enter the Company, Project and Site names to create them in the
Well Explorer
5000.1.7
Page 214 of 423
May 2010
Draft
Creation of Company, Project, Site and Contractor
Within the Create Well Wizard, a user with permission to the proper security
tokens, can create a new Company, Project and Site. This can be accomplished
by typing the name of the Company, Project and Site into the text boxes, instead
of selecting from the picklists. Using the same method, a user with permission to
the proper security tokens, can also create a Contractor within the Create Rig
Wizard.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Find a Well
Each Wizard allows you to select the location in the hierarchy where the item will
be created. If you are unsure as to where a particular Well is in the hierarchy, then
use the Find a Well feature to perform a text based search for the Well.
The Find Well feature is accessed by clicking on the
button. This button is
located in the Create Wellbore wizard, Create Event wizard, Create Daily Report
Wizard, Create New Report Wizard, Today’s Wells dialog and the Today’s Wells
Favorites dialog.
Figure 3: Find Well dialog
Today’s Wells (How is my Well Doing?)
The Today’s Wells feature allows OpenWells users quickly determine the accuracy
and completeness of their “Morning Report” data, without having to navigate
through a number of Wells and Daily Operations reports in the application or their
printed Daily Drilling reports.
This feature displays a pictorial representation of the Well along with pertinent data
on the operation state of the Well for a given day. Based on the Well’s Datum
information, either a Land or Offshore picture is displayed.
5000.1.7
Page 215 of 423
May 2010
Draft
Enter the name or partial name of the Well you are looking for and click the Find
button. A list of Wells matching the text is displayed. Select a Well and click OK.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 4: Today’s Wells for an Offshore Well
From the Today's Wells dialog a user can:
•
review the daily status of Wells and Daily reports across multiple Events
•
review the daily status of each of the Wells with Daily reports on the chosen
date by scrolling through “Favorites”
•
create and maintain a list of “Favorite Wells” that are available each time the
Today’s Wells dialog is opened per user
•
remove wells from the “Favorites” list after a well is no longer active
•
immediately identify and navigate to Non-Productive Time and Safety incidents
•
navigate to the day’s Operations Summary, Survey data, Bit Details and
Operations, Pump and Shaker Operations
•
identify costs that have gone over the AFE estimate
•
identify measured depths that are behind plan
•
view a schematic of the Well
•
view planned and actual Depth vs Days or Cost vs Days graphs
5000.1.7
Page 216 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
launch available Output reports for the Well associated with the Daily report
•
transfer the Well or Daily report to the office
•
refresh the Today’s Wells data
Four variations of the Rig Equipment Editor are available and appear based on the
Rig Type defined. The assignment of rig types to the four graphics is done through
the System Setting RigTypeImages. Detailed information regarding utilization of
that setting is documented in the EDM Administration Utility online help, “Configure
Rig Equipment Editor Images” topic.
Generic types supported are Land Rig, Semi-Submersible, Jack-Up and Drill Ship.
The OpenWells System Administrator must map their “Rig Types” to one of these
through the above System Setting.
Figure 5: Rig Type as defined in the Rig Properties dialog
5000.1.7
Page 217 of 423
May 2010
Draft
Rig Equipment Editor
The Rig Equipment Editor provides a simple way to locate, edit and enter Rig data
in OpenWells using an interactive picture of a Rig. This feature is available from the
main applications window and from the Data Entry Form window. The Rig
Equipment Editor allows users to easily view and maintain their Rig and Rig
Equipment inventory, without having to navigate through the Contractor’s Tab
within the main application window.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 6: Land Rig image
Figure 7: Semi-Submersible Rig Image
5000.1.7
Page 218 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 8: Drillship Rig Image
Figure 9: Jackup Rig Image
5000.1.7
Page 219 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Each Rig picture contains ‘hotspots’ for Rig Equipment. When the mouse hovers
over a ‘hotspot’, the equipment type turns red and a brief summary of the
Equipment type is displayed.
Draft
Figure 10: Hover mouse over Pump displays read-only summary
Clicking on a ‘hotspot’ opens a historical summary dialog for the Equipment type.
From this Summary dialog equipment can be created, edited and deleted.
5000.1.7
Page 220 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 11: Equipment Summary dialog for Pumps
To access the Rig Equipment Editor, click the
Wizard Toolbar or the Data Entry form toolbar.
button appearing in the
Edit Rig button
Figure 12: Edit Rig Button in the Wizard Toolbar and the Daily Operations form
If a Rig has not been associated with the Event, OpenWells allows you to associate
one when the
button is selected from within the Daily Operations form.
5000.1.7
Page 221 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
The Rig Properties dialog can also be accessed from the Rig Nav Aid, by clicking
on the Rig Properties button, located below the picture.
The following links are available from each picture:
Land Rig - Boilers, BOP, Centrifuges, Degassers, Hydrocyclones, Motors, Pits,
Pumps and Shakers
•
Semi-submersible - Anchors, BOP, Centrifuges, Degassers, Hydrocyclones,
Motors, Pits, Pumps and Shakers
•
Drillship - BOP, Centrifuges, Degassers, Hydrocyclones, Motors, Pits, Pumps
and Shakers
•
Jackup - BOP, Centrifuges, Degassers, Hydrocyclones, Motors, Pits, Pumps
and Shakers
Improved Hole Sections Data Entry
The Daily Operations report, Hole Sections area has been changed to allow users
to more easily enter Hole Sections with an alternate entry layout. Administrators
can now configure the Hole Sections area to record detailed hole section data,
including annular details or to expedite the entry of hole section data, when annular
details area not required.
OpenWells offers the following two sample layouts in the EDM Administration
Utility:
•
Daily Non Complex Well - This configuration simplifies the Holes Sections
data entry to one spreadsheet. Using this spreadsheet a user could enter all
their information on a hole section, including Last and Next Casing data, in
under a minute.
Figure 13: Non Complex Well Hole Sections layout for quick data entry
5000.1.7
Page 222 of 423
May 2010
Draft
•
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
Daily Drilling - This configuration is intended for users who will be entering
detailed information on the hole section, including Next and Last Casing and the
details of the annulus.
Draft
Figure 14: Daily Drilling Hole Sections layout for detailed data entry
Integration between the Well Planning Report and Hole Sections
Hole Section data entered in PROFILE planned and prototype Designs are now
available from the OpenWells Well Planning report, Hole Plan section.
Simultaneous Activity Monitor (SAM) rules apply to multiple users viewing or
editing the Hole Plan data in either application.
When a Well Planning report is created in OpenWells and linked to a planned or
prototype Design, Hole Section data entered in PROFILE will automatically appear
in the Well Planning report. Likewise, changes and additions made to the Hole Plan
in OpenWells are reflected in the appropriate PROFILE Design.
5000.1.7
Page 223 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 15: OpenWells and PROFILE Hole Plan
Within the Hole Sections of the Daily Report, the user will have the ability to copy
casings from a planned Casing for the Next Planned Casing information.
Figure 16: OpenWells Hole Section Select Planned Casing
Sub Assembly Support
Sub Assemblies created in PROFILE can be added or inserted into an OpenWells
Wellbore Equipment report if they were created in the ACTUAL design in
PROFILE.
5000.1.7
Page 224 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 17: Sub Assembly shown in PROFILE
Figure 18: Sub Assembly menu opened and Sub Assembly inserted into Wellbore
Equipment Report in OpenWells
New Rig Association Options
Rig Association functionality has been improved upon through the following two
new features: Rig Association in the Create Daily Report wizard and the Daily
Operations report.
5000.1.7
Page 225 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Rig Association in the Create Daily Report Wizard
Rigs can now be associated when creating a Daily report using the Create Daily
Report button, available in the Wizard Toolbar. The
button is now
available on the second page of the wizard. Clicking this button launches the
Associate Rig to Daily Wizard, which guides the user through the Rig Association
process. Once the association to the Rig has been made, the Daily Operations
form exposes Rig Equipment, such as Pumps and Shakers.
Draft
Figure 19: Associate Rig to Event in the Create Daily Report Wizard
Rig Association in the Daily Operations Report
Rigs can now be associated in the Daily Operations report form. The
button found can be found in each of the Daily report’s Equipment Operations
section. Clicking this button launches the Associate Rig to Daily Wizard, which
guides the user through the Rig Association process. Once the association to the
Rig has been made, the Daily Operations form is automatically updated and
instantly exposes the Pumps, Shakers, etc.
5000.1.7
Page 226 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Associate
Rig Button
Draft
Figure 20: Associate Rig Button gives the user the choice to select a rig or create a
new one from within the Daily Operations form
Figure 21: Rig has been selected and the Rig Operation is created
5000.1.7
Page 227 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Figure 22: Rig Equipment Operations sections are refreshed and operations data can
be entered
Draft
Output Report Enhancements
The following output reports have been reformatted to include cover sheets, tables
of contents and have an overall cleaner and more technical look. Further
reformatting will continue in upcoming releases.
•
Casing
•
Cementing
•
Stimulation
•
Wellbore Equipment
•
Well Test
•
Well Planning
•
Perforation
5000.1.7
Page 228 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 23: OpenWells 5000.1 Casing Report Page 1
A new feature to include both PROFILE Wall Plot Composer Plots and COMPASS
Plots within OpenWells output reports is now available. Below is an example of a
simple report which demonstrates a COMPASS 3D plot and a WallPlot called
“Directional Plot” from PROFILE.
5000.1.7
Page 229 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 24: OpenWells 5000.1 COMPASS Plots and WPC Plots Example
Documentation on implementing this feature or the general schematics feature can
be found in the EDM Reporting User Manual.doc file distributed in the
Documentation folder under your EDT_5000.1 install directory (i.e.
C:\landmark\edt_5000.1\Documentation).
5000.1.7
Page 230 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
OpenWells Fixed Issues
The OpenWells issues fixed for 5000.1.0 through 5000.1.7 are described below.
Release 5000.1.7
The following issues were fixed for the 5000.1.7 release of OpenWells software.
Description
172804
Implement BHA History as per DIMS
619699
Make the Hole Sections editor available somewhere outside of the Daily Ops DEF
622729
Need additional Tubing Pressure field for Flowing Test Sheet
623206
Need range of depths for peak gas.
623207
Please add Rate of Penetration to the Peak Gas tab of Daily Geology Report.
624555
BHA Operations records not always deleted when they are tied to a BHA and the
BHA is deleted.
625259
Need Volume of Oil Stored field in DST
631697
Enhancement needed to record fuel usage and run time of all motors.
631968
"Time Summary", "Total Time" should be dependent on "Group Activity Filter"
698566
Only one user can edit a report at one time
699704
Need ability to enter a DISTINCT clause in picklist filter
699899
Provide 'Days since shut in' field displayed in Jobs List
700561
Need a Remarks section in Event and Wellbore Properties
700697
Extend EPS to only output 'approved' reports
705566
Add "Cost Editor" similar to existing Survey Editor to display all costs entered for
event and allow editing without having to go back through all reports
717864
New Contractor field required in Casing Form
720414
703232 continuation: Allow to fill Work Strings and operations information from
Stimulation, coring and, logging reports.
721387
Request Min and Max fields for WOB, RPM, and RPM Rotating.
721800
Require new fields in Test Form
722180
Drillstrings planned in Profile Should be available in OpenWells in Well Planning
report and from there available to be imported as actuals.
726285
Wb Equip - Completion Notes support required
728203
Need sorting on Primary Work Unit internal picklist. NOTE: User can now provide
their own sorting on user picklists.
5000.1.7
Page 231 of 423
May 2010
Draft
DE
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
730057
Read Only User can still perform Unlock All or Lock All on reports.
730416
Dates should have a 'unit' showing the date format
730614
Customer would like an NPT logon to be created. This logon would grant RW access
to the NPT sections of reports and limit all other sections of the report as Read Only.
732631
EPS needs to handle Partnership Start & End Dates
739289
Coring Reference Log field not exposed in Coring form
743453
Cumulative Cost Issue when creating 2 report for One Day
745102
Request that the Event End Date be populated when the Final Report checkbox is
selected. Note: controlled by System Setting
748482
EPS generates error and does not create PDF's
750224
Publishing takes too much time to create .pdf report files
750359
CEMENT - Stage pumping schedule, auto-create first row when stage created.
750445
Need 'Flip Assembly' feature to resolve issue where user entering components in
wrong order
750510
Drillstrings - Require 'Show All' feature (toggle) to list all BHA runs for the Event.
Should include BHA Runs in parent Wellbores. Enables 'hidden; BHAs to be edited/
corrected.
750634
Have Drillstrings section auto populate the Progress in Bit Ops.
754529
Customizing OpenWells Test data entry form layout results in fields disappearing in
form
755089
Internal picklists require better support for Design Phase values
755488
Assembly in Located Inside picklist in Casing Report doesn't appear in sidetrack
757370
Accessing EPS Interactive takes hours for the Interactive tab to fully list all DEF's in a
10,000 Well database
759691
No individual security on Pick tables
760179
Additional fields required for Material Transfer
760602
Unit system can be edited even with "EDIT" application default token set to revoked
763605
The tabbing order of the arrival/ departure checklist of the New Job wizard is not
intuitive. It would be better if it went to add row, down the arrival, then add row, down
departure list as opposed to across the way.
763757
Request for Enhancement to Assigning Partners into the Wellbore and Event
Properties
764932
Expose the letter code field in the Offload Pipe Tally spreadsheet.
769756
Enhancement request for OpenWells Input data to be saved automatically to prevent
from losing data in case of power off. Note: Controlled by a System Setting. See
Online Help
5000.1.7
Page 232 of 423
May 2010
Draft
DE
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
770759
Event Transition: When Transitioning Events using Copy Records from Event Tool, it
is not possible to carry over costs.
773825
OpenWells needs to filter actuals vs planned and prototypes in the Copy from
Previous/Planned Drillstrings dialog.
785214
The "Create a new rig" option after creating a contractor in the contractor tab does
not check the EDM.Explorer.Rig.add security token.
785215
The "Create a new rig operation" option after creating a contractor and a rig in the
contractor tab does not check the EDM.Explorer.RigOperation.add security token.
795342
Users have no ability to control the sorting of Daily Costs. Even if the up/down
arrows are used, the sequence is not carried over to the next day.
795722
Clients cannot configure displayed columns in internally defined picklists - for
example Umbilicles tab hard to identify components -
796627
Missing Summary Property pages for some Rig Equipment
798029
Can not generate Wellbore Schematic and BHA Schematic in a single Report
798858
BHAs out of order on OpenWells Daily Output Report when Options Screen is
removed.
799036
There is an Exception pops up when you add more than 300 rows in Cost Estimate
and AFE report.
799155
Add CD_DEFINITIVE_SURVEY_HEADER to WYZWIG
799487
Deleting pump does not delete pump op in the database.
799507
If no casing section is added to the Hole Section Details spreadsheet, Length equal
Depth, should be MD base - MD Top.
799914
Casing Output Report - Not showing Job Activity section.
799917
Wellhead Output report - missing "total component cost"
799941
General Work Output report - doesn't show Work Operation "duration" field.
799958
Daily Geology Output report - No Value on Daily Cost and Cumulative Total field.
The DEF shows a value on these calculated fields.
800043
Cementing Output report - doesn't have Workstring and Job activity
800114
Daily Drilling Output Report - No Fluid Management Content.
800239
Missing alternate currencies against 4 unit classes
800945
Cementing Output Report Fluid Pumped Out of Order - sort by sequence_no
801170
Association between a custom Data Entry Forms and WYSIWYG to show is lost
after upgrade.
801418
Proposed Set MD in Drillers Running Pipe Tally Report
801831
PUMP OPERATIONS - The Pump Efficiency is not defaulting from Pump definition in
Rig tab
5000.1.7
Page 233 of 423
May 2010
Draft
DE
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
801885
Clone of 731662 Would like to have more Rig Operation fields in Associate Rig
Operation wizard to avoid navigation to Contractor tab
802006
Additional fields needed to capture various information in CD_WELL. Need to add
them to the Well Property dialog too.
802110
Clone of Defect 767874 - Filter the list of contractors/rigs available in the Associate
Rig Wizard off of event by start date and end date
802370
Clone of 750474 - Drillstrings - Show a warning listing Bit and BHA Ops associated
prior to deleting the BHA Run.
802609
Clone of defect 755091 - Well Explorer does not refresh to show found Search item
802622
Clone of 801881: Sibling records not deleted when section type is changed
802668
Add field: Excess Lime to the Water Based Mud Properties tab in the Fluids Section
of the Daily Operations Data Entry Form and Daily Operations Output Report.
802774
Clone of 802003 Application crashing when the Military Grid Reference System is
used
802800
CLONE of 735476 Request that User Audit information be added in the Daily Cost
Spreadsheet.
802915
CLONE of 801379 Bit Summary and BHA Summary output reports do not show all
bit runs/bha runs if there are no bit/bha ops under them.
802927
CLONE of 750615 Copy To/Move To command should automatically navigate to the
node above the item you are trying to copy.
802950
CLONE of 796360 Confusion for users on what date format is required for different
fields
802965
CLONE of 750638 - Drillstrings - Convoluted workflow required when sidetracking so
that sidetrack BHA can be seen in sidetrack wellbore
803202
In the Daily WYSIWYG's BHA section, changing a Section Type of a component and
then cancelling out of the Catalog Selector still change the data on the Assembly
row.
803367
CLONE of 799500 Eff. Hole Dia should be used to calculate Linear Capacity for
Open Hole.
803375
Clone of 802379 - Deleting a BIT component only deletes the Bit Operations for the
current Daily
803376
Clone of 802811 Rig Operation Summary does not check if rig operation is in use
before deletion
803378
Clone of 750476 - Survey Station MD is being auto populated. Someone thought this
would be a good idea, but the users find it inconvenient.
803503
How can we get the formation tops report?
803735
Clone of 755089 - Internal picklists require better support for Design Phase values
803838
Cost Est AFE Output Report - Est Base Currency Not Calculated Correctly
5000.1.7
Page 234 of 423
May 2010
Draft
DE
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
803843
CLONE of 749709 Changing Rig On Location date for associated Rig Operation
results in Daily forms not showing Rig in the Data Entry Form Window Title Bar; <NO
RIG> shown instead.
804310
CLONE of 804087 TVD is not showing on the DDR output report.
804320
No TVD calculated when no surveys can be found. This is related to D/E 769197.
This works well when surveys are entered, but not well between surveys. Need a
compromise on the behavior
804375
CLONE of 750467 Deleting Rig Op-Event link data is impossible, OpenWells states
you can't do it as reports already exist.
804380
CLONE OF 731661 Need method to associate a Report(s) to a different rig to clear
up instances where a report is associated to the wrong rig
804544
CLONE OF 803198 -When a Assembly Component's Section Type is change, the
associated data with the previous section are deleted immediately (not able to
recover).
804624
CLONE of 804496 Datum is not refreshing after import.
804626
CLONE of 804092 Table of Contents and Cover page options should be disabled by
default
804645
CLONE OF 803838 Cost Est AFE Output Report - Est Base Currency Not
Calculated Correctly
804908
Mud Product Transaction calculated values can be off if there are duplicated
daily_id's
804908
Mud Product Transaction calculated values can be off if there are duplicated
daily_id's
804971
CLONE OF 804647 - Associate Rig Operation to Event should force the user to
close off previous rig ops for same rig
805418
User wants to add Safety - Incidents spreadsheet in WYSIWYG that is in Form View
805421
Please add spreadsheet for Notifications in WYSIWYG
805450
Proper fix for the DE801285 - ArrayIndexBoundsException and Could Not Save
Form.
805502
Old Rental Summary Report
805557
Clone for Rocket - "Could not save the form" error relating to Bulks and Mud
Inventory after using VCR Next and Previous buttons
805559
LOT Summary Report in OpenWells giving wrong values on base axis.
805618
Clone (766760) to Test in Rocket - Unable to select no assembly (blank) in
Cementing report
805829
D/E Report times out after 15 minutes
805974
User can edit Read Only Daily Operations DEF by double clicking in Hole Section
fields
5000.1.7
Page 235 of 423
May 2010
Draft
DE
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
806032
Perforation - Intervals - MD Top and MD Base are not showing up unless CCL@ and
CCL-TS are populated
806318
Bit Summary Report Heading is listing all wellbores for the well when it should only
show wellbores for the selected event.
806546
Final Pipe Tally Report - "Attach Section" functionality is incorrect and affects the
Tally No in the output report
806641
Event Property-When adding rig op, then default time on Rig on Location is 00:00
806676
Creating Geology Report Creates Orphan CD_FLUID_T record
806719
BHA Deletion is not refreshed when no is selected on Save Changes Window.
806735
NPT Summary Properties / NPT Equipment Failure Properties- Format issue when
Contractor Section is hidden.
806856
REQUEST: Add new unit to Class 171 aka "Concentration (Chlorides)"
807015
MMS Well Activity Form 133 Output Report - request that Section 13 be sorted by
date.
807288
Datums may show default datum checked when table cd_datum.is_default = 'N'
807409
Casing Reports - Incorrect Hole Size appearing
807464
EDM Admin - Property Dialogs changes are not being saved/respected
808036
ENHANCEMENT: OpenWells 2003.16.1.17 - Selecting casing assemblies whilst
sidetracking
808379
Pipe Tally Report shows only 110 records instead of 136
808395
Add more audit field to daily cost spreadsheet
808545
In Drilling pipe tally report the cumulative length calculate the length of first joint
although it is flagged out.
808802
Not able to enter CD_CONTRACTOR information on wysiwyg
808990
Enhancement: increase event_type on the MD_SITE_EVENT_TYPE to 40 character
809043
Recorder information in Drill Stem Test report is not being shown properly.
809291
Increase length of Age Code on Company Properties for Strat Units
809638
Wysiwyg needs to accommodate fann data readings
809874
PK_STATE should be the default picklist for State/Prov in Well and Site properties
810045
Fluid Hauling Data Entry Form does not keep Fluid Source and/or Fluid Destination
name if add a new line in form
810354
The total AFE shows up correct value whereas when you take the print preview of
Operations Summary CharT, the total AFE mentioned is way much more than the
correct value.
810655
Removing Surveys from Well Designer/Trajectory tab once added (no Compass).
5000.1.7
Page 236 of 423
May 2010
Draft
DE
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
811700
The total AFE shows up correct value whereas when you take the print preview of
Operations Summary CharT, the total AFE mentioned is way much more than the
correct value.
811703
Pipe Tally Report shows only 110 records instead of 136
811800
CLONE OF 808551 Fluid Management - Fluid Disposal. Request to be added to
WYSIWYG Form
811801
CLONE OF 811732 Add DM_CUTTINGS, DM_SPILLS, DM_FLUID_DISPOSAL,
and DM_FLUID_DISCHARGE to Wysiwyg
812063
Require the ability for PROFILE to be able to display Stimulations across multiple
Events
812085
Cement rendering issue due to bottom depth comparison
812940
System Settings are not included in a Configuration Transfer export
813325
Clone of 813325 If Rig op has been removed from the associated rig (event
properties) - the rig key should be deleted from ALL reports not just DEF
813353
Text area name are not customized for Partner Contacts Editor
813595
Site Properties defect. Notes Field (cd_site.Remarks) is not visible in EDMAdmin
814134
Well Obstruction Component Ordering not working
814134
Well Obstruction Component Ordering not working
814620
Obtain NPT hours as a percentage of the event total hours in a single report.
814773
Error in Create New Report wizard if no tokens granted
814958
Deleting company data in POB causes orphan data without using the "Clear
Company Daily Information" button. POB general workflow is not intuitive to uses.
815060
OpenWells AFEvs Actual Report - Currency field missing. Our ref #121
815108
Add CO2 presence CHECK BOX for a Well
815397
Extend Associated Data Viewer so that it shows Report Level Attachments at Event
Level
815401
Allow internal picklists to have Sort and Filter Clause
815914
DO - Workstrings - no place to enter parameters for Progress Summary
815922
Copying Daily Operations report also copies associated rig
816165
Need BHA Operations fields for off and on bottom circulation pressure
817090
Wellbore equipment report blank fields
817594
Need UI Drill days in DM_RIG_OPERATION
818145
The last page of report has no page number.
818205
Profile draws Packer outside wellbore equipment string, when it should be located
inside
5000.1.7
Page 237 of 423
May 2010
Draft
DE
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
818615
PROFILE 2003.16.1.23 We have issues with the Stimulations data entered against a
specific event that appears to be related to dates of event yet all stim data is within
the start end date of specific event
818829
Enhancement - Additional fields in Time Summary
818841
PROFILE issue rendering Cement around Slotted Liner Completion in Multi-Lateral
Well displayed incorrect on interactive schematic
818843
LOT Summary Output Report - Test Data does not grow correctly to the next page.
819195
Please provide "Auto Catalog Select" On/Off Option in OW for the whole company
as well as per user basis
819347
PCP Report DEF > General > Landed MD depth does not use Datum
819387
Wellbore No. field cannot be made read only - Wellplanning Report/Hole Sections
OR 251
819605
Using the Create Wellbore Wizard does not populate Wellbore API like if use File New -Wellbore or by right clicking on a Well to create new Wellbore
819794
OpenWells - Progressing Cavity Pump Report - Rod Guides indication is not present
on R5000 OP report. Shell OR#186
819799
OpenWells-Today's Wells Screen - How to configure the transfer button.
819812
OpenWells 5000.1.4: MD sort order messed up in BHA section (output report)
819825
Pumping Schedule on Cementing output report not in correct order as entered on
Data Entry Form
820149
Custom Water Based Mud tab in fluids section of Daily input form does not change
after applying customization
821389
Need spare fields in DM_ACTIVITY
821907
Client wants to add a field on a Data Entry Form that calculates a value based on
other fields.
821988
Dm_Safety.remarks - Enhancement request to increase Dm_Safety.remarks test
field from 225 to 500.
822218
RELATED TO 750445: Profile: Need 'Flip Assembly' feature to resolve issue where
user entering components in wrong order
822265
Remove WYSIWIG Button from DEF when WYSIWIG disabled
822530
The schematic in the Cementing output report is not showing the hole section,
casing, cement, etc. entered on the same day as the Cement Report Date.
823723
CDRS report generation unable to generate Norwegian characters correctly in
2003.16.1.25.
824868
UPGRADE: "Casing Name" picklist in OpenWells Cement Program Details to
include Liners from StressCheck design.
825096
Changing Active Unit System in Profile changes Datum stored in database
5000.1.7
Page 238 of 423
May 2010
Draft
DE
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
825335
User wants NPT Summary report to have a column for duration type ET = Equipment
Failure and a column for other NPT types e.g ODHP
825412
Wellbore schematic does not appear if datum missing - User wants a warning
message added to crystal report to let user know datum is missing like in Profile
826507
Create new from copy button should automatically put in new BHA Date and Time In
from the previous BHA Date and Time Out.
826898
Request Northing and Easting on Anchor Position in Daily Anchor Operations.
826901
Copy plan formations from Compass design to OpenWells, Wellbore Properties,
Formations tab
828195
Duplicate daily_id from different wells cause error in cum hrs and cum footage
828358
Request wellbore name, corrections to graph, headings on the cover page, and Rig
Name and No. are not printing on the LOT ( Leak Off Test Summary ) Output Report.
828577
DEFECT: PROFILE: Crash Opening Designs - application crashes with no error
828586
PROFILE SCHEMATIC: schematic draw incorrect - conflict caused by cement and
casing shown incorrect
829718
OPENWELLS > DATA ENTRY FORMS > PERFORATION REPORT > Intervals
spreadsheet is not remembering data entry order. > Index should be created on this
table to retain order that this data is entered on spreadsheet
829725
OPENWELLS - OUTPUT REPORT - PERFORMATION - not sorting the data
adequately - should sort intervals by MD Top
830264
Parent wellbore blanking in Compass after OpenWells save
830468
SQL Server 64 bit Install's keep installing every time I run EDT 5000.1.7 install on top
of EDT 5000.1.5
830469
EDT 5000.1.5+ upgrades unpack Historian files to Temp folder irrespective of
whether user wants to install Historian or not
831061
CD_ASSEMBLY.remarks field exposed for ACTUAL designs
831288
Copying Cost Records from another well results in incorrect cost_date.
831399
Daily Data Entry Form Cost fields do not always recalculate and/or refresh from Mud
Inventory updates.
831461
Multiple Reports with the same date from the same well aren't being sent out
832097
A valid time may not be accepted when entering a time on a Survey.
832112
New Wellbore Wizard - place Wellbore No. field before Well Legal Name and
Wellbore Common Name fields
832113
New Event Wizard - Add DM_EVENT.event_type to bottom of New Event
Information area
832120
New Rig Operation Wizard - default Contractor and Rig Name picklists to null.
832122
Extend Event Reporting Standard to Jobs
5000.1.7
Page 239 of 423
May 2010
Draft
DE
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
832136
NPT Properties, Equipment Failure tab - make Failure MD field available on this tab
(as well as General tab)
832287
Daily Operation > Drillstring (BHA/Bits) > Components > BHA length needs to
include Drill Pipe and Drill Collar if the Drill Pipe is within the BHA
832288
Daily Operations Report POB needs to be redesigned.
832350
Graphical Well Summary Report
832643
MUD INVENTORY: Add two columns Vendor & Function
832783
Cannot delete Perfs out of the Wellbore Openings tab if they were created in a
Perforation Data Entry Form
832846
Display issue with Well Planning Report - number of rows shown in Planned
Operations
832847
Need cum totals on Wellplanning Report for Hole Plan time and cost numbers
832875
Clone of 830692 to track fix in Rocket: Rows lost from
DM_WELL_PLAN_WELLBORE_LINK during upgrade from 2003.16.1 to 5000.1.5.2
833091
select a casing from parent wellbore in Cementing Report.
833189
BHA's are not sorted correctly in WellPlanning Report - Drillstring Program.
833881
CLONE OF 805186 TO VERIFIY IN 5000.1.7 DEFECT: Related to DE#803185
Compass 2003.16.1.17 Build 68, causing corruption of OpenWells 'Build
2003.16.1.17.8055 'entered Casing reports
834768
Wellhead report - API Temp Rating picklist display wrong characters for
temperatures (-50¿F/-46¿C to 180¿F/ 82¿C)
Release 5000.1.6
No OpenWells issues have been fixed for the 5000.1.6 release.
Release 5000.1.5
The following issues were fixed for the 5000.1.5 release of OpenWells software.
Defect No.
Description
741059
Modifications to the Perforations Report do not get reflected in the Wellbore
Openings tab
812106
Clone of 766760: Unable to select no assembly (blank) in Cementing report
797133
OpenWells incorrectly calculating well surface location when well location is defined
by reference to slot.
5000.1.7
Page 240 of 423
May 2010
Draft
DE
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
805541
Require component "description" field to be available in all catalog types.
814332
Navigating between Daily Ops reports loses focus on the active section
798340
ENHANCEMENT - add AFE Number and Description to Event Operation Summary
Report
812240
wrong calculation of total pages in Material Transfer Report
812243
There is no option to let user hide cover page and index page when user previewing
the Daily Well Operations Report
812246
Report content error-Leak Off Test Summary Report
812296
EPS fails to generate reports filtered by reporting standard on the next day resulting
in lost reports
812808/
812810
After installing the software, log into OpenWells as a standard user; application
throws error “...file path is not a directory...\Queries\Drilling...” or “...file path is not a
directory...\Queries\Rushmore...”. This only occurs on the FIRST launch of
OpenWells after installation (and then only if the user logs in as a ‘standard user’—
i.e., not Administrator). 
WORKAROUND: After installation, log into OpenWells as Administrator one time.
All subsequent launches of OpenWells will now work when user is logged in as a
standard user.
813089
5000.1.2 AFE vs Actual report: A loop was evaluated more than the maximum
number
815232
Cost vs. Days stops "growing" at a certain point for no reason
811389
OpenWells R5000 Memory Usage Performance Problems
813407
Clone If Rig op has been removed from the associated rig (event properties) - the rig
key should be deleted from ALL reports not just DEF
814542
CITRIX - User can login to OpenWells w/o username and password or Win Auth
815840
Finish button won't activate unless selecting a different event when Dragging and
Dropping Report from one event on one well to another Event on a different Well
816812
Drillstrings - Create New From Copy doesn't show strings from other wells
814764
Report Cover Page logic not working
815037
Time Distribution Report displaying incorrect values
816495
Unable to add a survey in OpenWells in certain situations.
5000.1.7
Page 241 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.4
The following issues were either addressed or have workarounds for the 5000.1.4
release
Description
801881
Sibling records not deleted when section type is changed
802003
Application crashing when the Military Grid Reference System is used
801741
AFE v Actual crashes with supplement AFE
802379
Deleting a BIT component only deletes the Bit Operations for the current Daily
796360
Confusion for users on what date format is required for different fields
801379
Bit Summary and BHA Summary output reports do not show all bit runs/bha runs if
there are no bit/bha ops under them.
799500
Eff. Hole Dia should be used to calculate Linear Capacity for Open Hole.
804091
No TVD calculated when no surveys can be found. This is related to D/E 769197.
This works well when surveys are entered, but not well between surveys. Need a
compromise on the behavior. System Setting required. See documentation
804087
TVD is not showing on the DDR output report.
804496
Datum is not refreshing after import.
804092
Table of Contents and Cover page options should be disabled by default
802811
Rig Operation Summary does not check if rig operation is in use before deletion
749709
Changing Rig On Location date for associated Rig Operation results in Daily forms
not showing Rig in the Data Entry Form Window Title Bar; <NO RIG> shown instead.
750467
Deleting Rig Op/Event link data is impossible, OpenWells states you can't do it as
reports already exist.
735476
Request that User Audit information be added in the Daily Cost Spreadsheet.
750476
Survey Station MD is being auto populated. Someone thought this would be a good
idea, but the users find it inconvenient.
750474
Drillstrings - Show a warning listing Bit and BHA Ops associated prior to deleting the
BHA Run.
731661
Need method to associate a Report(s) to a different rig to clear up instances where a
report is associated to the wrong rig
714409
Copy Existing String should default to current Well and Wellbore
732834
Date/Time fields should have masking format so that the user only has to type the
numbers.
731662
Would like to have more Rig Operation fields in Associate Rig Operation wizard to
avoid navigation to Contractor tab
755091
Well Explorer does not refresh to show found Search item
5000.1.7
Page 242 of 423
May 2010
Draft
DE
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
755090
Internal Picklists require better support for Is Hidden columns
786797
Rig Key in DM_REPORT_JOURNAL is not deleted if Rig Operations has been
removed
767874
Filter the list of contractors/rigs available in the Associate Rig Wizard off of event by
start date and end date
750615
Copy To/Move To command should automatically navigate to the node above the
item you are trying to copy.
750498
PUMP OPERATIONS - The Pump Efficiency is not defaulting from Pump definition in
Rig tab
755089
Internal picklists require better support for Design Phase values
750638
Drillstrings - Convoluted workflow required when sidetracking so that sidetrack BHA
can be seen in sidetrack wellbore
805431
Could not save the form error relating the Bulks and Mud Inventory when using the
VCR Next and Previous Buttons
Release 5000.1.3
No OpenWells issues were fixed for the 5000.1.3 release.
Release 5000.1.2
The following OpenWells issues were either addressed or have workarounds for the
5000.1.2 release.
Defect
Description
165404
Request: AFE vs. Actual cost printout report should be dual currency compatible.
612757
Cannot use a network drive in File Monitor Directory.
622388
Field for Max OD in Casing Report
627775
Need to be able to assign planned Rigs to Job via Rig Operation when previous Rig
Op(s) are not yet completed
630078
Need additional Duration columns (3) for Planned Operations
632010
Field to Office Data Transfer tool needs to show if reports have attachments
700873
Request that the Cost Estimate and AFE spreadsheet entry be changed to allow the
insertion of items in between other items, sorting of items, and have the items be
saved in the order that they were entered.
700935
Implement automatic re-connect support to SAM when it goes down
5000.1.7
Page 243 of 423
May 2010
Draft
DE
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
705972
Cement Fluids Calculated Sacks does not have a unit defined - should be 'sacks'
716777
Report locks are not flagged to other con-current users
720881
EPS Login Failure dialog inconsistent w/ other EDT applications
723609
Encrypted transfer files not deleted automatically by Receiver service
725216
Unit system does not have lbm/cuft or g/cc for Density. Please add these units
725356
Field Office Data Transfer and Report Locking
731641
Field to Office Transfer Utility needs some file cleanup functionality.
733028
Extend EPS Configuration Dialog to support new Option to only send outputs once
Report is Locked
733554
Output Reports from Publishing Service need to be configurable by Event Type
733579
Need better error/process logging in EPS to diagnose adverse behavior
735063
Request to show all NPT reports available for day/well
736897
Request that Data Requester remember the data source for log in to the office.
737125
Encryption Check Box and Working Directory FTP settings not saved correctly for
FOT Configuration
742263
TVD BH, Depth Tab, Wellbore Properties Not Updated from COMPASS
746214
Incorrect Class Assignment for Swell Period on the weather input screen - should be
Time with a unit of Seconds
747097
With AutoCatalog Off in DEF, Bit Operations tab in Drillstrings does not get activated
as a Bit row is added
747339
Need to restart OW for WP DEF's Total Target Duration, Target Cost and AFE Cost
to be correctly calculated (after navigating from WP DEF to AFE DEF and back)
748759
Test Report: Test Method Swabbing does not show all Fields in Swabbing Test
749141
Last Hole Section's last Leak Off Test spreadsheet is not always highlighted
749347
Spell Check not working
749613
Bits Information grayed out after you copy the string from a different well
749714
Component row copy results in user changes not being adequately saved as seen
from PROFILE
750354
Cannot delete BHA Components unless BHA Sensor tab is visible
750454
Wellbore Properties - trip Surface Location calculation (from KOP MD value = 0)
when new Wellbore created
750454
Wellbore Properties - trip Surface Location calculation (from KOP MD value = 0)
when new Wellbore created
750461
FODT does not recognize dropped VPN connection
5000.1.7
Page 244 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
750464
LGC EDM Data Receiver Service - Does not check for database connection when
processing an import. Result is that transfer files go into 'Fail' folder and are no
longer able to be processed.
750466
LGC EDM Data Receiver Service - does not recognize old files, they are ignored. If
the files are in the folder, process them.
750490
Spell Check feature does not process correctly when there is only 1 spelling mistake
in field - displays "No Error" but makes but then loses the correction
750505
Rig equipment updated on field machine e.g., new pump not updated on office
system after transfer from the field
750569
Daily Operations DEF: If we add Surveys in Survey section, TVD value is not
refreshing in General section.
750605
Refresh issue. Wellbore Equipment components don't show in ESP. Have to exit out
of OpenWells and restart.
750661
When opening OpenWells, remembers last selection, but tree does not automatically
navigate to that selection.
750695
Wellbore Equipment / Casing components had been entered into the DEF are
missing in the spreadsheet but the MD Landed shows a calculated depth.
750928
Survey - new survey defaults the Azimuth to the Convergence
751423
EPS cannot generate the reports when transfer the Event level report.
752099
EDM File System Service doesn't pickup and append manual EDM export XML files
753348
If the customer doesn't refresh the data in Receiver's OpenWells, the locked
transferring data also can be edited.
753856
Transferring a Casing/Test/AFE/DO DEF does not update the Section Complete
status in an OW session on the receiver
753857
AFE DEF does not get updated in open OW session after Successful Import
754211
Need 'OPEN' & 'CLOSED' items added to MD_PK_COMPONENT_STATUS system
picklist.
754967
Layout Manager - Making the Approvals or Associated Completions tabs invisible
will adversely affect the layout and functionality of the entire Event/Job Properties
window
754968
Expose all DM_EVENT fields to Layout Manager.
755014
The updating component details in PROFILE cannot be populated in the Wellbore
Equipment DEF, unless region OpenWells.
755085
Data Validation display does not show Depths adjusted to the current RDL
755109
Online Help needs a correction concerning Contingency Costs.
755574
Parent Wellbore field does not support multiple Sidetracks in the same day
758967
Firing up multiple DSIMP.bat can cause the Receiver machine to hang or be
responsive for long periods of time
5000.1.7
Page 245 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
760163
Field/Office Transfer Status Dialog when using FTP not showing file transfer to
remote site.
760166
Would like ability to merge output reports when saving to file.
760230
Batch Print Wizard should enable selection of reports from other Wells and Events
just like DIMS
760631
Is there anywhere in OpenWells where you can enter information about "prefrac"?
760895
Issue with hole sections on Daily Drilling Report after side track.
763436
14.1.5 onwards: Cannot Save or close DEF after entering LOT - Pumping Details
763436
14.1.5 onwards: Cannot Save or close DEF after entering LOT - Pumping Details
763477
Changing Time Summary Time, causes incorrect NPT Times as Nested NPT and
Net Time is not automatically calculated
764053
D/E Request new jobs, job transfer tool issues
765683
Hole section MD base defaults to MD current when creating a new hole section.
765845
Perforation Report - Why do MD Top and MD Base Default to the Datum Value?
766384
Rig Op Release Date Limitation hinders Pad Drilling Workflow
767043
Need application security support to control user access to Move/Copy Report
feature
767169
We need to honor the sequence_no in CD_VG_METER
768492
Changes to Casing Output Report - Add MD Base, change column order
769197
TVD Values change when switching between Daily Operations DEF's.
769582
EDM Data Receiver Service needs SAM support to automatically notify active
OpenWells users when new reports have come in and when updates have been
made to existing reports
769630
Enhancement - Ability to edit EPS Email Subject Line
770939
Daily Cost records do not carry over to a new wellbore.
772325
Duplicate default datums created
772435
Well Planning DEF, Sidetracks Area, Spreadsheet, Design field combo box change
is not changing detail panel
774866
Make it possible to attach the custom java code (class/jar) for a single table along
with the Report file instead of putting in commonext.jar
775645
Annulus details - depths do not respect viewing datum, results in incorrect
calculation of open hole length.
776059
WYSIWYG Bit "Bottom to Top" Button
776155
NPT Gross/Net Time Defect
777668
PSA CDRS report - unable to map a field to gasReadingInfo/gasHigh
5000.1.7
Page 246 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
779707
Right Click Options (Cut, Paste, Copy, etc) are not available on the forms
781778
Well Planning DEF, Directional Drilling Plan section
CD_SURVEY_PROGRAM.hole_name picklist is not updating
782298
Request that the Well Explorer delete message tell which nodes are locked when
delete will not execute due to locked nodes.
782601
Rig Op Release Date Limitation hinders two active rigs on the same Well Workflow
783492
Daily Drilling Output Report should show all AFE Numbers associated with the
Event.
783493
Request that the AFE No. field be added in the cost detail lines in the Daily Cost
Output Report.
783929
Need a link to Rig Operations for editing from the Rig Equipment Editor
784212
C:\temp\dsmail not automatically created and not automatically purged
785125
Tie on point does not use the reporting standard, but all other survey stations do.
785341
SAM message not sent for new rigs
785419
OpenWells Exchange Rate should be utilized to view cost oriented reports.
785868
Extra white space displayed for Time Summary
785888
Locked fields in Well Explorer can be edited through Daily Operations WYSIWYG
DEF
786933
Duplicate Datum when copying Well Planning Report
787323
Cannot access BHA Ops, Bit Ops and BHA Sensors tab in Layout manager to
customize
787362
Custom WYSIWYG not being imported with configuration import
787797
Clone of 773149: NPT ending activity missing values for new report scenario.
787799
Clone of 773150:Improve wording on NPT copy/move warning dialog.
788941
UPGRADE: Automate a process to clean up used temp files created by FOT.
790188
Clone of 790084 - Daily Personnel Section - People on Board tab should look up
company using well_id, event_id, and company_id.
790442
Report Generation Error - Java Running Out of Memory
791329
Rig Association not always updating unless close and restart OpenWells
791471
FOT audit update Date/Time displays one digit for time(Minutes) like 10.1am.
791533
Time Summary - Duration column sometimes updates
791799
Surface Tanks Calculations do not calculate correctly from one day to the next in the
Daily Workover Fluids Section
792105
Clone of 790338:Memory increase while browsing around OpenWells Hierarchy
causing slow performance
5000.1.7
Page 247 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
792467
The Actual Design has no associated datum when the user deletes the associated
datum.
792556
R5000.1 does not depth shift log collar depths
792809
When the MD in the Daily Entry Form - General Section is raised, then the Hole Size
and BHP fields no longer calculate.
792903
Adding a new NPT without an end date disabled the NPT button and doesn't display
the NPT created
793222
Deficiency in Save Logic for Time Summary
794369
When a survey is imported, then the Save icon does not activate.
794414
When entering a Perforation Interval, the Top MD and Base MD cannot be entered
794965
Clone of 793109: Need to enter value for <drillReport><versionKind>.
794967
Clone of 793110- Need to enter values for <porePressure><readingKind>
794968
Clone of 793112 - Need to be able to report values for <gasReadingInfo><gasLow>.
794994
Data displayed in the Operation Summary Chart incorrect
795044
Hiding of BHA Sensors tab (in Drillstrings of Daily Operations Data Entry for) causes
newly added BHAs to not show up
795243
Metadata is not loading for output reports when network userid has a special
character
795296
Request option to not print the TOC on the Casing and Cementing Reports.
795341
OpenWells FTP needs to support Passive mode
795346
D/E Not being able to add DM_ACTIVITY.wellbore_zone_id to spreadsheet
795355
Well Planning Report Hole Plan Section records should stay in the order entered.
795357
WellPlanning - Wellbore Formation - TVD and Base TVD not displayed on output rpt
unless fill in MD and MD Base
795408
PK_EQUIP_FAILURE_TYPE cannot be ordered how we want it.
795642
Need tree model for Under-Balanced Drilling WYSIWYG
795663
Associated Partners Contacts, Data Disappears on Picklist Fields
795695
Depth Reference tab allows multiple Default Datums to be selected
796154
Cannot delete BHA Components unless BHA Sensor tab is visible
796155
Picklist will not disappear after a Section Type is selected in the
Drillstrings>Components tab
796592
Supplemental AFE cost records remain after Supplemental Header is deleted.
796889
Unable to customize or hide Reporting Tab in Event Properties
797013
OpenWells Event Property page not picking up configuration upon Event creation
5000.1.7
Page 248 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
797050
AFE vs. Actual Report should not include daily cost amounts that are related to
another AFE.
797053
Multi-Well AFE vs. Actual report should not drop daily cost items when there is no
matching item in the AFE.
797199
Created NPT/Failures in Time Summary does not display
797417
When a Project, Site, and Well that is sent has no tight group selected, then the
Receiver fails with no error message.
797998
Print Wizard Print Queue dialog minimizes when the Options dialog comes up.
798049
CDRS report generation unable to generate Norwegian characters correctly.
798057
Cementing Report add Slurry Top TVD and Slurry Base TVD to Fluids section
798213
Add Flowback model to Stimulation Wysiwyg
798778
Clone of 791606: Error copying/pasting assembly component spreadsheets in a
customized spreadsheet or importing after copying out to Excel
798889
OpenWells is caching too many wells
799227
Making changes and immediately cancelling changes to Tie-on-point can cause
Wellbore Properties to show wrong values for Top of Hole KO
799303
Clone of 798818 - OpenWells and COMPASS interaction with SAM and surveys
creating too many SAM messages and OpenWells marking surveys edited that are
not
799614
Tie on point is not showing up on newly created Survey.
Release 5000.1.1
No OpenWells issues were fixed for the 5000.1.1 release
Release 5000.1.0
The following OpenWells issues were either fixed or have workarounds for the
5000.1.0 release.
Defect ID
Description
178457
Can you pass parameters to the shortcuts in the launch bar
619710
For Wellbore Equip reports, need ability to store these assemblies to a library
619913
Need the ability to import from a Library on the Components Casing Screen.
622375
Threads Tested Field
622381
New Field in Casing Report
5000.1.7
Page 249 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
622384
TV Depth in Casing Report
626495
DM_COMPANY_DAILY.num_people is not updated correctly when removing all
personnel
628904
User can't see this new Rig Equipment on the report.
705993
Well Planning Hole Sections do not integrate w/ PROFILE and the Tubular
applications
722401
Request that the Hole Sections Section of the Daily Report be changed to make it
easier to understand for beginning users.
726999
No area available to enter free text comments for an installed component
731341
Wellbore KOP Coordinates should be local to Well location, not Site location
731358
When promoting site to FINAL append the scouting description text instead of
overwriting.
733398
Need Drilling Mud Motor RPG stored against Motor definition and Total RPM
calculated in each Daily Report Bit Operation
733458
Layout Manager - need DM_DAILY.liner_top field exposed
745332
Need fields to support IHMP and FHMP
746745
Nowhere to enter Tag MD when installing ESPs below Underreamed section
747263
Leak Off Test calculation in SI units differing by a number as compared to API
747433
WP DEF - Hole Plan Totals should be subtotaled by the current wellbore/design as
that design is shown in the dropdown
747474
Include Tool Description in Survey Tool Picklist, Survey Properties Page
749130
Survey Properties dialog showing wrong TVD value for Side Tracks.
749174
Print Report Wizard--Save the Print Report Wizard Preferences and have ability to
see complete Summary Reports section
749621
AFE Report should not be deleted when AFE association is deleted in Event.
750453
Support simple Hole Sections data entry w/out requiring Details spreadsheet.
750495
Pump Operations sub-spreadsheets not intuitive to use.
750854
Gas Concentration (class_id=186)
752198
If possible we need to have an option to invoke Rig Equipment Properties (Pump
Ops, Centrifuge Ops etc) from DO DEF
753590
OpenWells 2003: New units required 100 lib. Sack & 50 lib. Sack
753694
Need to change some default labels in stimulation form
755377
Loss of cursor Focus in Spreadsheet Headers
755413
No place to record Off Bottom Circulating Pressure
5000.1.7
Page 250 of 423
May 2010
Draft
Defect ID
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
755431
Document 702876 - Need EPS support for Auto Publishing 'Changed' Reports so
that reports can be re-cached when reports are changed in office
755441
Cleanup DEF - Site Cleanup section - Spills tab - Button is not called "Import from
Daily Operations", but "Import from Event(s)
755442
Documentation: If required the new elegant Import from Event(s) dialog in Cleanup
DEF - Site Cleanup section's - Spills tab - "Append and Replace Spills" options
755448
Document the new feature of how OW is unique in bring in Well Name/API number
from Well Properties to Well bore Properties
755449
Documentation: New feature: Contractor/Rig properties now has Start and End Date
fields
757232
Cannot start and end the Hole Section on the same day
757325
Request Operator and Reporting Time fields in the Event Properties.
758092
Document how to Increase the maximum JVM size (-Xmx) to 1024m in the
OpenWells batch file
758202
Require Communication Y/N and Communication Remarks field in Stages section
758206
'Actives Stages' should be labelled 'Active Stages'.
758353
Find feature won't find items contained within Virtual Folders
758734
Site Location for Romanian, Belgian and Bell Wire geographic reference systems
are different between Open Wells and COMPASS
759196
Daily Mud Cost does Not get recalculated when we delete the rows in Mud Inventory
even after saving and reopening
760168
Survey selector in Survey Properties problems w/ SI units
760175
Casing form does not see Pipe Tally form that was just created
763095
MD_PK_PROD_FAILURE_TYPE has no way to be internationalize without breaking
the functionality
763107
OpenWells Survey Header Tie-On Point Coordinates for Wellhead origin does not
respect 'Well Centre' coordinate setting for Local Coordinate System configuration in
Project Properties.
763275
WYSIWYG DDR - Print Data Entry form: Print of page view does not fill the 81/2 x 11
sheet. Printed text area is only 4/14 x 7 1/2.
764928
User requests Final Pipe Tally Output Report and Driller's Running Pipe Tally Output
Report have separate column for spare joints listed in the Pipe Information section
766385
Need 'Formation Gradient' field to support alternate MASICP workflow
768500
Add Wellbore Name to Bit Summary Output Report
768617
Request that EDM Publishing Service not select reports in the future.
768892
OpenWells spreadsheet import does not honor any customized settings in regional
settings with regards to digit and decimal separators
5000.1.7
Page 251 of 423
May 2010
Draft
Defect ID
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
769081
Clear transaction description is missed under help menu.
769347
Daily occurrence of SAM error
769593
Update/Highlight in the Online Help that the Wellbore Schematic displays the well
status at the end of the Reporting Period
770137
OpenWells Survey Header Tie-On Point Coordinates for Wellhead origin does not
respect 'Well Centre' coordinate setting for Local Coordinate System configuration in
Project Properties."
770262
Must close and re-open OpenWells for deleted pit to go away on Fluid Volumes.
Refresh problem."
770525
In WYSIWYG, by default Survey Tie-On is User Defined and MD is set to the Datum
Elevation, not to 0.
770771
Wellbore Status History no longer updating Plugback MD
770903
New resistivity fields are needed for the Logging Report.
770937
unable to delete rows from Personnel section with People on Board tab hidden in
DEF
771010
OpenWells, output report doesn’t show the last saved days length for drill pipe in
daily operations drill string section
771037
Unit System Editor: Gas-Oil Ratio. where is m3/m3 unit?
771071
<Set default values for Mud Inventory Cost Description on Daily Cost Section>"
771091
Need the ability to support multiple WYSIWYG forms and assign them per preferred
data entry form
771159
Dsimpserv.xml could grow to an unmanageable size
771187
Copy/Paste problem in Time Summary spreadsheet
771469
CDRS wellAlias does not allow for user to pull from CD_WELL
771471
CDRS mappings do not allow for literals in the mappings
771505
Daily Cost not populating in Daily Cost Output Report for items not in AFE
771558
Hole Section, MD Base field does not autopopulate/update from current MD until the
DEF in closed and reopened.
771625
On Daily Operations report, field DM_ACTIVITY.Time_To of Time Summary tab is
not working properly.
771631
Copy Well Planning report workflow results in 2 'Planned' Designs within the same
Wellbore."
771999
Allow validation rules to be defined as mandatory.
772005
FOT takes about 10 minutes to transfer a simple company after a long time in idle
state.
5000.1.7
Page 252 of 423
May 2010
Draft
Defect ID
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
772323
Survey Properties - OpenWells enables users to tie-on Surveys associated to
Wellbores not tied to the current Wellbore
772488
Daily Air Drilling Output Report does not show Sections if Hole Section not Present.
772515
Require support for "Rockies" location descriptions.
772658
Move DO DEF from Well 1 / Well bore 1/ Event 1 to Well 1 / Wellbore 2/ Event 1
causes NPT to disappear
772753
Wysiwyg showing same wellbore for all rows in the hole section spreadsheet
772954
Datum Elevation Should Read 'from Mean Sea Level'
772990
Security Tokens are not working for Attachments
773014
Duplicate Casing OD and MD Shoe values are shown in Actual Casing section of
Depth vs Days Graph
773117
Attachments to NPT and attachments to lessons attached to NPT do not get moved
when a DO report is moved.
773125
Deleting a report with an associated NPT does not delete the NPT nor the lesson
associated to the NPT.
773598
OutOfMemeryError while copy/move a daily report for Oracle.
774506
CDRS wellboreAlias/name and wellboreAliasNamingSystem will not honor two
records
774507
CDRS wellboreInfo/RigAlias information missing tag for NPD Code
774523
Problems with wellDatum tab in CDRS XML result
774543
Casing Output Report issues: MD Top label is missing and Top Connection OD &
Bottom Connection OD values are interchanged in Output Report.
774922
DDR Printed Report - Report Options Dialog needs select all and clear selection
options.
775072
Schematic in Well Planning DEF shows the actual and not the planned data.
775073
MD vs Cost graph needs to display details of NPT and casing.
775896
Details Sections Do Not Appear In LOT, BHA Ops, Bit Ops Until Header Line Is
Clicked For The First Time In OpenWells
777044
OpenWells PSA CDRS report, need to map a database field to what is currently a
hard-coded value in Time Summary
777048
PSA CDRS report, unable to map field for temperature tool depth value
777049
PSA CDRS, Logging section is invalid for temperature details
777093
Report Manager Error when Cost Estimate and AFE has no entered cost rows.
777218
PSA CDRS report, unable to map fields for lithShowInfo/tvdTop or tvdBottom
777308
PSA CDRS report - need to map a field to formTestInfo/dominateComponent
5000.1.7
Page 253 of 423
May 2010
Draft
Defect ID
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
777668
PSA CDRS report - unable to map a field to gasReadingInfo/gasHigh
777786
PSA CDRS report, unable to map fields for wellTestInfo/tvdTop or tvdBottom
777792
PSA CDRS, unable to map wellTestInfo/presFlowing
777956
PSA CDRS report - access DM_ACTIVITY table from controlIncidentInfo
778103
PSA CDRS, 6 mandatory fields in wellTestInfo with no way to map them
778994
Daily Actual Costs items do not show on AFE vs. Actual Report if there is no
matching AFE item.
779171
Off-Load Pipe Tally Output Report Corrections
779265
Online Help lists the incorrect directory path that the .bar file is saved in when
creating new system shortcuts
779341
Cost Records are not sorted according to Code and Subcode.
779388
Copying a well planning report into a different well misses planned designs &
surveys for side-track wellbores in the well planning report.
779580
Survey Header - Tie-on Point not calculated correctly when tie-on point is on a
survey in another wellbore.
779901
WYSIWYG form allows user to change fields that they don't have access to.
781366
CDRS Change the output unit of gasReadingInfo/gasHigh to '%'
783909
Use label to indicate Wellbore Properties General Tab Vertical Section is referenced
from Well-Center.
783989
A user who does not have EVENT.LOCK right is able to lock ALL reports via the right
click menu from EVENT.
5000.1.7
Page 254 of 423
May 2010
Draft
Defect ID
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
OpenWells Known Issues
The following OpenWells known issues for releases 5000.1.0 through 5000.1.7 are
described below.
Release 5000.1.7
There are no additional OpenWells known issues for the 5000.1.7 release.
Release 5000.1.6
Draft
There are no additional OpenWells known issues for the 5000.1.6 release.
Release 5000.1.5
There are no additional OpenWells known issues for the 5000.1.5 release.
Release 5000.1.4
There are no additional OpenWells known issues for the 5000.1.4 release.
Release 5000.1.3
There are no additional OpenWells known issues for the 5000.1.3 release.
Release 5000.1.2
The following are known issues for the Engineer’s Desktop 5000.1.2 release.
Defect
Description
792911
Refresh issue. Wellbore Equipment components schematic image doesn't show up
in ESP. Have to close and reopen the ESP DEF to see the schematic.
795050
Error printing WYSIWYG Print Data entry form on Vista to a file
795590
Deleting Fluids on Stimulation Report doesn't remove them from them from the
Schedules area Fluid Dropdown in Form View until form is reloaded
797323
Report Manager - Cancelling action - an exception error is generated
797988
OpenWells Daily Operations DEF: Hole Section Depth is not automatically
recalculated.
5000.1.7
Page 255 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
798029
Can not generate Wellbore Schematic and BHA Schematic in a single Report
798295
Prompted to save form whenever a spreadsheet date gets focus
798314
3D wellbore graph does not show other wellbores
798877
Default User Symbol Folder for Save Symbol pointing to old folder
798982
Creating a new design - entering a new hole section - if you switch between Unit
Systems - hole section disappears
799036
There is an Exception pops up when you add more than 300 rows in Cost Estimate
and AFE report.
799391
Time Summary Total time (Calculated field) is not updating, when switching from
WYSIWYG to Form View
799424
In Daily Operation Report, when a Bulk item is deleted, the corresponding Bulk
Transaction records are not deleted from the database
799425
LayoutDDR wysiwyg - Report number + report date is inconsistent between the
Report frame title bar and the report drop down box (beside the vcr buttons), when
using the vcr button to navigate between reports.
799487
Deleting pump does not delete pump op in the database.
799555
LayoutDDR-wysiwyg, able to Add row to spreadsheet even if Report is Locked
799572
NULL Date displayed as 12/31/1969 in WISYWYG Shaker
799575
In DDR, deleting a tie on point of a survey gives a wrong error message.
799589
OpenWells well explorer - grammar mistake in dialog
799590
OpenWells well explorer allows blank names if renaming directly in tree instead of
from right click Rename menu
799595
In Create Daily Report Wizard, Help button and F1 display Report Command help
instead of Create Daily Report Wizard help
799723
EDM Admin Tool: does not show updated files in XML Preview Panel after import
site config files without a restart
799766
The ComBox in Template Time Related Setting should not allow user to type text
799779
Tab "Approvals" in Event Properties dialog not updated correctly with report
referenced ON
799914
Casing Output Report - Not showing Job Activity section.
799917
Wellhead Output report - missing "total component cost"
799941
General Work Output report - doesn't show Work Operation "duration" field.
799946
Report can be locked using Event Lock All even without a particular report lock token
granted.
799957
Stimulation DEF, Fluids section calculations not updating for
DM_STIM_FLUID.volume_squeezed DM_STIM_FLUID.volume_washed without F9
5000.1.7
Page 256 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
799958
Daily Geology Output report - No Value on Daily Cost and Cumulative Total field.
The DEF shows a value on these calculated fields.
799959
Daily Geology Output report - doesn't show Lithology "Interval length" field.
799977
Tight Group's description does not show non-Latin characters correctly
800064
Daily Cost Output Report doesn't show Dual Currency Fields
800114
Daily Drilling Output Report - No Fluid Management Content.
800147
BOP list not refreshed without a restart after import
800156
Cannot tab from field to field in Hydrocyclone Details entry form
800401
Copy WellPlanning report generates exception in a certain obscure workflow
Release 5000.1.1
There are no additional OpenWells known issues for the 5000.1.1 release.
Release 5000.1.0
The following are OpenWells known issues for the 5000.1.0 release.
Defect
Description
772941
CD_MATERIAL.temp_deration_sched_id, radial_yield_factor, and hoop_yield_factor
were moved to CD_GRADE. Update OpenWells with this change.
773979
Cleanup: User defined 'Sump Sampling' from Construction DEF is not getting
associated
774866
Make it possible to attach the custom java code (class/jar) for a single table along
with the Report file instead of putting in commonext.jar
774965
Jobs tab, Can not delete Job attachments from Associated Data Viewer.
774966
WYSIWYG, DDR: Data Dictionary is showing by default Date only for Survey Start &
End fields in Survey Data section but the fields are displaying Date and Time.
775222
Virtual Folders created in PROFILE are displayed in OpenWells if we disable the VF
feature also.
775337
New Job Wizard, Exceptions are throwing while importing data in Arrival & Departure
Checklist Configuration spreadsheets.
775492
Drill Stem Test Output report, needs to remove column lines in Flow Period section.
Some of the Flow Rate section column lines are displaying in Flow Period section.
776120
Contractors tab, can not access Rig Operation Properties using shortcut key
(Ctrl+Shift+O). It is always opening the Air Package Properties because the shortcut
key for Air package Properties also same.
5000.1.7
Page 257 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
776389
Entering a Casing row below the Open Hole and selecting from Casing Report
causes Length to populate incorrectly
776444
Cannot Copy/Paste attachments from one node to another node.
776594
OpenWells, Contractor tab, Rig equipment should be sorted by install date in the
preview pane
777354
Copying the Rows in Hole Plan area of the Well Planning Report moves the focus to
Offset Wells
778281
IndexBoundsException when you switch to Wells tab after deleting wells node from
jobs tab
778350
User should not be allowed to cut the rows using shortcut keys and save the
changes in System Catalogs
778930
Some fields are not importing the values once we Export and Import the Wellhead in
Wellhead DEF.
778931
Clicking on Empty Formation Name picklist in Kick DEF is throwing Null Pointer
Exception.
778932
Event/Job Preview Pane is not displaying completely, it is displaying some white
patch.
779226
Multiple Rheology sections not supported from the WITSML 1.3.1 Fluids file
780361
Need to restrict the field length for Sidetrack No. field in Add Sidetrack/Multilateral
Wizard. Sidetrack No. field is accepting more than two numbers (eg: 001) and
throwing exception on screen.
780362
Need to restrict the field length for Version No. field in new Design dialog. Entering
more than 20 characters throwing unexpected exception.
780948
Daily Ops DEF personnel section shrinks every time you select a row
781186
Well planning casing program spreadsheet sorting is messed up
781540
We can delete DPR Submissions in OW Performance Reviews after Revoking
'OpenWellsPerfReviews.DPRSubmission.delete' token also.
781685
OpenWells- VISTA only. Color scheme messages.
781778
Well Planning DEF, Directional Drilling Plan section
CD_SURVEY_PROGRAM.hole_name picklist is not updating without a refresh
781927
Streamline the SAM message dialog for Well Planning Report when more than one
OpenWells have the same report opened.
781966
Creating a well planning DEF, cancel button is not working properly in the new
design window
782009
Copy Stimulation report from Library is not copying many fields.
782013
ADV, for Lessons, click on X button in Confirm Delete dialog is deleting the lesson.
5000.1.7
Page 258 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
782058
Copyright information is wrong on all preview panes - says 2006
782369
OpenWells Well / Rig Explorer 'Rename' functionality allows entries in the explorer
tree to be renamed with a null value.
782389
Clone of 777925 - PSA CDRS - unable to map equipFailureInfo/equipClass - default
value is not usable.
782494
OpenWells output reports- Well Planning Reports - final page - highlighting
strangely.
782503
Wellbore properties - bottom hole location not populated first time
782683
Actual Design doesn't get created from OW Daily Ops or Well Planning Report
782688
Well Planning Report/ launching PROFILE
782777
For a user with no add (token) right for any reports, the 'Next' button in the Create
Report Wizard dialog is messed up.
782965
OW display Multiple default Datum on import.
783177
In consistent wizard dialogs. Some has OpenWells icon and some doesn’t
783180
Rig name in rig properties dialog doesn’t get refresh on the rig image title bar when
using the wizards
783195
Hole Section add/delete rows appends if not saved after deletion
783293
Daily Operations DEF, Survey station for a new survey header always default to
Normal instead of Tie-on
783371
Convert Unit (F4) should be disabled for read-only and calculated fields
783409
Lock Wellbore Properties in RTV and clicking on OK button throwing 'OpenWells
could not refresh tree correctly. Please check log message' on OpenWells screen.
783632
Problem: While entering data in Fluids FANN table Daily Report, after tab out from
the deflection field to next row, the prior field (deflection field) it is still focus as active
while the next row (RPM field) first field is also focus but apparently no
783643
Save Failure while creating a Company and adding a Partner without saving
Company first
783718
Number of decimal places should dynamically change with unit system change.
783721
Wellplanning Report Directional Drilling is setting the TVD of the first survey station
equal to the md
783929
Need a link to Rig Operations for editing from the Rig Equipment Editor
784011
OW, Wizards has a disabled <Back> button next to finish button which will never be
used. Remove the back button if there is no next button on the wizards
784095
Selecting Rig Type in the Create New Rig Wizard without using the mouse doesn’t
display in the Rig properties dialog, hence wrong Rig image displays
784178
Moving Daily Operations DEF from one Well to another Well throwing exceptions
with a particular data set.
5000.1.7
Page 259 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
784211
Standardize shortcut for Delete to match rest of D&C
784222
DDR WYSIWYG - Mud Inventory Spreadsheet Invalid Value Message Box is not
closing when clicking "Yes" to continue editing the cell.
784224
DDR - WYSIWYG - Ctrl C/ Ctrl V - should not be working for these Spreadsheets, no
copy and paste available from menu
784231
WYSIWYG survey data section, user shouldn’t be able to insert survey stations
same as in Form view
784267
Wellbore Properties ask for Save even though no changes have been made.
784308
Catalog button should be disable when the Drillstring Section is Locked by SAM.
784338
OW Performance Review (Rushmore) - Wrong tab index order
5000.1.7
Page 260 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
PROFILE™ Software
Enhancements
Fixed Issues
Known Issues
The 5000.1.7 release includes all supported platforms, plus enhancements, fixes, and
known issues from the 5000.1.0 and subsequent EDT releases. Bug fixes were made to
PROFILE for the 5000.1.7 release.
The PROFILE enhancements and new functionality for releases 5000.1.0 through
5000.1.7 are described below.
Release 5000.1.7
There are no enhancements for the PROFILE 5000.1.7 release.
Release 5000.1.6
There are no enhancements for the PROFILE 5000.1.6 release.
Release 5000.1.5
•
Includes several PROFILE schematic fixes and 3 WELLPLAN defects from
2003.16.1.22.
•
Fixed issues showing status of strings/components in the schematic.
•
Approval Process - The OpenWells and PROFILE applications now includes a
feature to mark and identify Wells, Events and Reports that have gone through an
approval process. The approval process preserves and locks the information
recorded about the Well/Event/Report at the time of approval. The information
preserved for a Well includes the Well’s data and its Events, Wellbores,
Completions and Reports data. The information preserved for an Event includes
the Event’s data and its Reports. 

Any PDF files that are attached to an approval point are electronically signed when
a Well, Event or Report is prepared for approval and when the Well, Event or
Report is approved.
5000.1.7
Page 261 of 423
May 2010
Draft
PROFILE Enhancements and New Functionality
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Approval Tokens - New tokens have been added to the EDM™ Administration
Utility to support the new Approval feature. Admin.Historian.edit,
EDM.Explorer.approve, EDM.Explorer.Well.prepare,
EDM.Explorer.Event.prepare, EDM.Explorer.Report.prepare and
EDM.Explorer.Well.viewapprovalhistory.
•
Approval Point Stamp Location - The location of the Approval Point PDF stamps
in the OpenWells and PROFILE applications can be configured using a system
setting. See the PDF Approval Stamp topic in the EDM™ Administration Utility
online help.
•
New Report Manager Version - A new Report Manager version, which will reduce
memory consumption, increase report generation speed, and contains various
other improvements.
•
PROFILE Schematic Tokens - Three new PROFILE system settings can now be
added to the EDM database.
— Dual Centered Components - assign specific components to always draw
centered on dual completions.
— Low Priority Components - assign lower priority to certain components drawn
in a schematic that can be smaller than others to make more room for the more
important symbols.
— Use 2D Symbol Scaling - render the 2D packer symbols, expand the casing so
it doesn’t
— need to bend the dual completions and also use a few other options only
normally needed by the 2D symbol set.
Release 5000.1.4
There are no enhancements for the PROFILE 5000.1.4 release.
Release 5000.1.3
•
New platforms are supported.
•
Mobile Checkout licensing feature libraries were added.
Release 5000.1.2
The PROFILE™ 5000.1.2 release is an incremental update of the 5000.1 version of
the PROFILE software release. A number of enhancements and new features have
been added for this release. New features provided with this release include:
5000.1.7
Page 262 of 423
May 2010
Draft
•
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Sequential Schematics - Sequential Schematics enable users to display
schematics with a large number of components in a neat and easily readable
fashion. The Sequential Schematic object allows users to break a schematic down
into a number of sections, thereby improving the schematic displayed.
•
Concentric and Dual completions display sequentially in the Wall Plot, a line
appears across the schematic showing where the overlapping equipment occurs
or where the second completion begins.
•
Stimulation Treatments - The Stimulations tab now contains a spreadsheet to
enter Treatments data. This allows users to record multiple treatments being used
during a Stimulation Job.
•
Workspaces - Workspaces can now be used to create a group of Wall Plot
templates that can be applied to any Design in a specific order.
In addition the following enhancements have been added to this release:
•
The Wall Plot Composer's 3D Graph now shows all of the Well's sidetracks, with
the current wellbore displayed in blue and all other wellbore paths are displayed in
black.
•
The Components spreadsheet of the Drillstrings/BHA tab can now be set to
automatically calculate the Drill Pipe length. See the “Auto Calculate Drill Pipe
Length” topic in the online help.
•
A number of enhancements have been added to the Wellbore Schematic Tracks
tab, the Sequential Schematic Tracks tab, the Wellhead Schematic Object
Properties Tracks tab and the Multi-Lateral Schematic Properties - Tracks tab,
including:
— Text Wrap Limit: A text wrap limit has been added to the Tracks tab to reduce
overlapping schematic tracks.
— Import Schematic Track: An Import Schematic Track button has been added to
allow users to import pre-configured Schematic Tracks from a .STRACK file.
— Export Schematic Track: An Export Schematic Track button has been added to
allow users to export pre-configured Schematic Tracks to a .STRACK file.
These tracks can then be imported and used in another Wall Plot.
— Duplicate Track: A Duplicate Track button has been added to allow users to
make a copy of the selected track.
5000.1.7
Page 263 of 423
May 2010
Draft
•
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Sequential Schematics
Often, a Wellbore containing numerous components does not display in the Wall
Plot Composer in a neat and easily readable fashion. The Sequential schematic
object solves this problem by allowing users to break a schematic down into a
number of sections, thereby improving the schematic displayed.
A visual example of the difference between a schematic displayed using the
Wellbore Schematic and the same schematic displayed using the Sequential
Schematic is outlined below. This example shows a Dual completion, but the
Sequential schematic works the same way for Concentric completions as well.
5000.1.7
Page 264 of 423
May 2010
Draft
Concentric and Dual completions display sequentially in the Wall Plot, a line
appears across the schematic showing where the overlapping equipment occurs
or where the second completion begins.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 1: Dual Completion as shown using the Sequential Schematic
Alternative methods to add a Sequential schematic to the wall plot page:
•
Right-click on the wall plot page, select Schematic > Sequential Equipment
from the drop-down menu. Move the cursor to the wall plot page, click and drag
an opening for the schematic to be placed on the wall plot.
•
Click the Sequential Schematic button ( ) in the Object Toolbar. Move the
cursor to the wall plot page, click and drag an opening for the schematic to be
placed on the wall plot.
The Sequential schematic object can contain a number of tracks which may include
Casing Details, Casing Depths, Wellbore Equipment Depths and other information
as well as the drawing itself. A number of different schematic track types are
supported. Tracks can be selected using the Tracks tab in the Schematic Object
Properties dialog.
5000.1.7
Page 265 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Stimulation Treatments
The Stimulations tab now contains an additional spreadsheet to enter Treatments
data. This allows users to record multiple treatments being used during a
Stimulation Job.
The top spreadsheet provides a means to enter the Stimulation Job. The middle
area of the tab provides a means to record one or more Stimulation Treatments
that are pumped into the Well for each Stimulation Job. The bottom spreadsheet
allows you to enter specific Stages of each Treatment.
Figure 2: Stimulations Tab in the PROFILE™ application
5000.1.7
Page 266 of 423
May 2010
Draft
Each of these spreadsheets are inter-linked, meaning that you must select a
Stimulation Job to view the Treatments used during the Job and you must select a
specific Treatment to view the Stages occurring during the Treatment.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Workspaces
In the PROFILE™ application, workspaces are used to create a group of Wall Plot
templates that can be applied to any Design in a specific order.
Note:
Workspaces in the PROFILE application perform much the same way as
they do in the WELLPLAN™ application, but are different than the
WELLPLAN Workspaces.
Workspace Folder Notes:
Local drives, mapped network drives and UNC paths are supported.
The Workspace folder defined must already exist. The PROFILE
application will not create the folder.
The user must have permission to change the registry setting
HKEY_LOCAL_MACHINE\Software\Landmark\EDT\5000.1\Profile string
value Workspace Folder. By default, most users should have permission.
In the case of a Citrix environment, the Citrix Administrator may have to
set the Workspace folder for the Citrix PROFILE users.
Caution: If the Workspace Folder location has been set by the
Administrator in a Citrix environment, check with them before changing it,
as you may affect other users.
Working with Workspaces
Workspaces are created when a group of existing Wall Plots is saved using the
View > Tabs > Save Workspace command. Each Wall Plot is saved to an individual
.PPC file in a folder named for the workspace. For example, the following
screenshot shows the files that make up a Workspace called “Completion”. This
workspace contains 4 pre-defined Wall plots BHA Summary 2, Directional
Completion, Wellhead Summary and Summary. A .PPC file appears for each of the
defined Wall Plot templates.
5000.1.7
Page 267 of 423
May 2010
Draft
Workspace Folder
Prior to creating a Workspace a location where the Workspaces will reside must be
defined. The location is defined using the Edit > Workspace Folder command and
entering the location.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 3: Workspace and the template Wall Plots.
Notice the numbering on the Wall Plot file names. This numbering defines the order
in which the Wall Plot will appear in the application.
If a user were to apply the sample Workspace shown above to an open Design, the
four Wall Plot templates would be applied to the Design.
Figure 4: Sample “Completions” Workspace applied to a Design. Notice each of the
Wall Plot templates that have been applied to the Design.
The number appearing before the .PPC file indicates the order in which the Wall
Plots appear in the design.
5000.1.7
Page 268 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.1
WELLCAT was added to the EDT suite of applications for the first time in the 5000.1.1
release. Also, some Common Well Explorer enhancements were made. (See EDT™
Software for details). This update release improves the import/export and sharing of
Grades, Pipes/Connections between StressCheck and WELLCAT, improves the
integration between StressCheck and WELLCAT, and repairs critical defects affecting
key StressCheck and WELLCAT application functions. No enhancements were made
to the PROFILE software.
The 5000.1.0 release of Engineer’s Desktop supports the Microsoft Vista operating
system, has new LAM (FLEXnet Publisher) licensing and contains some critical bug fixes.
Well Cost was added to the EDT suite of applications for the first time in this release. For
the PROFILE application, the following enhancements were made:
•
Sub Assemblies are now supported within PROFILE. This allows for portions of a
Completion String (i.e., the Sub Assembly) to be planned independently and then
inserted into the overall wellbore equipment string.
•
Added or enhanced content of Data Boxes for the following objects:
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
•
Sub Assemblies
Wellbore Details for Multi-Lateral Wells
Perforations
Cementing
Reference Datums
Wellbore Formations/Wellbore Zones
Wellbore Equipment Details
Wellhead Equipment
Casing Assembly Details
Well Summary
Hole Sections
Mud Program
Well Remarks
Stimulations
Wellbore Openings
Other Data Track and Data Box enhancements to Wall Plot Composer
— allow sorting of components in Wellbore Equipment Details and Casing Details
— allow insertion of current date/time
5000.1.7
Page 269 of 423
May 2010
Draft
Release 5000.1.0
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
— allow control of decimal places
— filter out cement that has been drilled out
— multiple pages of a PPC can be grouped and printed out at once
Sub Assemblies
A Sub Assembly is a sub-set of the completion assembly. It is made up of a group
of adjacent tools, provided by a single service company, that are constructed,
assembled, tested and then sent to the Well site to be installed with other Sub
Assemblies. Engineers designing and installing completion assemblies need to be
able to manage completion make-up by Sub Assembly.
The Sub Assembly tab displays a visual representation of the selected Sub
Assembly string in the Well Designer tab and allows for the collection of Sub
Assembly data, such as:
•
name,
•
number,
•
number of sub assemblies delivered,
•
identify the primary Sub Assembly run (in the case where more than one is
delivered),
•
the vendor who provided the Sub Assembly, along with their contact details,
•
comments,
•
and installation instructions.
5000.1.7
Page 270 of 423
May 2010
Draft
To address this, PROFILE now contains a Sub Assembly tab. This tab allows users
to build a Sub Assembly from a list of components, using the same methods
available to the Wellbore Equipment tab (i.e., drag/drop, manual entry and/or
catalog integration). Jewelry and Umbilical properties are also available from the
Sub Assembly tab. Users can add and edit Sub Assemblies or use the Sub
Assembly Library to Import or Export Sub Assemblies.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 1: Sub Assembly Tab in PROFILE
Sub Assemblies in the Wellbore Equipment tab
In the Wellbore Equipment tab, a Sub Assembly can be inserted or added to the
end of the string using the Add Sub Assembly button ( ) and the Insert Sub
Assembly button ( ) located in the Component Details spreadsheet. PROFILE
does not allow components to be added to the middle of an existing Sub Assembly.
The Sub Assembly mode button ( ), in the Wellbore Equipment tab, allows users
to see what components belong to each Sub Assembly. Each Sub Assembly is
highlighted in a different color. Components that are not part of a Sub Assembly
are highlighted in grey.
5000.1.7
Page 271 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 2: Schematic showing two sub assemblies; one in blue and one in green
When this mode it turned on, users can click on adjacent components and create
a Sub Assembly from in the Wellbore Equipment tab. This can be accomplished by
selecting a number of adjacent components, right-clicking on the components and
selecting the Create New Sub Assembly command from the menu that appears.
Once created users can click the Sub Assembly button ( ) at the top of the
Wellbore Equipment tab; select the new Sub Assembly; and click the Copy to Sub
Assembly Tab button ( ) to add the Sub Assembly to the Sub Assembly tab to
use it in building more Wellbore Equipment strings.
5000.1.7
Page 272 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 3: Select Components to create new Sub Assembly
Figure 4: Click Copy to Sub Assembly Tab button to add new Sub Assembly
5000.1.7
Page 273 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Sub Assemblies can be added to the Wall Plot Composer using the Wall Plot
Composer’s Object Toolbar. A schematic of all components supported in the Sub
Assembly can be added using the Sub Assembly Object button ( ) and tracks
can be added using the Data Box button ( ). An example of a Sub Assembly Wall
Plot Composer layout (SubAssembly.ppc) is included with the installation. By
default, this file is located in the <5000.1 install directory>\Profile folder.
Draft
Figure 5: SubAssembly.ppc sample
Wellbore Equipment tracks can be configured to highlight Sub Assemblies in the
Wall Plot Composer.
5000.1.7
Page 274 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 6: Sub Assembly components highlighted in the Wall Plot Composer
Data Box Enhancements
Several fields have been added to Data Boxes to support more Wellbore details.
Additionally, the following new Data Boxes are now available for Perforation tracks:
Planned Cement Program, Mud Program, Well Remarks, Wellbore Formations
and Wellbore Zones within Perforation tracks.
Users can also filter cement that has been drilled out, control decimal places on
numeric fields in data tracks and control detailed string component sorting.
5000.1.7
Page 275 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Multi Page printing
PROFILE now allows users to print multiple pages of a PPC file at one time. By
default, this feature is turned off. It can be enabled through the File > Enable MultiPage Printing menu command.
Draft
Figure 7: Enable Multi-Page Printing command
PROFILE notifies the user if any pages are set to different printer page size and
verify scaling options.
New Completion Symbols
Four new completion symbols are now available in PROFILE. These symbols were
developed in conjunction with the Halliburton Completions Engineering team.
Figure 8: New Completion symbols
5000.1.7
Page 276 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
PROFILE Fixed Issues
The PROFILE issues fixed for 5000.1.0 through 5000.1.7 are described below.
Release 5000.1.7
The following issues were fixed for the 5000.1.7 release of PROFILE software.
Description
810655
Removing Surveys from Well Designer/Trajectory tab once added (no Compass).
812063
Require the ability for PROFILE to be able to display Stimulations across multiple
Events
812085
Cement rendering issue due to bottom depth comparison
818615
PROFILE 2003.16.1.23 We have issues with the Stimulations data entered against a
specific event that appears to be related to dates of event yet all stim data is within
the start end date of specific event
818841
PROFILE issue rendering Cement around Slotted Liner Completion in Multi-Lateral
Well displayed incorrect on interactive schematic
822218
RELATED TO 750445: Profile: Need 'Flip Assembly' feature to resolve issue where
user entering components in wrong order
825096
Changing Active Unit System in Profile changes Datum stored in database
828577
DEFECT: PROFILE: Crash Opening Designs - application crashes with no error
828586
PROFILE SCHEMATIC: schematic draw incorrect - conflict caused by cement and
casing shown incorrect
831061
CD_ASSEMBLY.remarks field exposed for ACTUAL designs
Release 5000.1.6
No additional PROFILE issues were fixed for the 5000.1.6 release.
Release 5000.1.5
The following issues were fixed for the 5000.1.5 release of PROFILE software.
Defect No.
Description
95126
PROFILE should be able to draw ‘Y’ blocks and ‘H’ members of a completion string
777656
Event dates in OpenWells causing problems in Profile
784951
Symbols are being squashed in the schematic so they only show a straight line.
5000.1.7
Page 277 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
790056
Pip tag information does not show up on the Wall Plot Composer
790273
Error in Well sketch with Production Liner and Fish
795610
Components appearing at the wrong locations in the schematic on diagrams in
Profile.
800563
Schematic scaling issue with units.
806531
EPS Configuration screen - Well list filters should be stored in and used from a
shared folder.
807697
EPS does not name file exports correctly if report_no is null
808734
EPS can not generate reports against some large Oracle databases
809947
ReportManager does not generate more then one Profile or Compass WallPlots
810631
Enhancements to the schematic engine to better support drawing of dual
completions and Y-Tools using 2D symbols.
Note: See required system settings above to enable and control the behavior of
Profile when drawing schematics.
810633
Provide the option to draw schematics with a constant diameter based on the
assembly size.
Note: This change requires the user to enable the "Use Assembly Size for
Component Diameters" option in the "Well Designer" > "Schematic Detail" menu in
Profile.
810634
Provide a way to include the users credentials as a signature when generating
wellplots.
811016
Status of strings/components (Installed / Pulled / Partial Pulled) is not always
respected in Schematic i.e Retrievable Packer & Casing cut
812752
PROFILE 5000.1.2 crashes in the Citrix environment
813738
PROFILE closes when adding wellbore equipment - Vista only.
817151
Clone of 759384:Profile WPC become unusable across application
Draft
Defect No.
Release 5000.1.4
No additional PROFILE issues were fixed for the 5000.1.4 release.
Release 5000.1.3
No additional PROFILE issues were fixed for the 5000.1.3 release.
5000.1.7
Page 278 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.2
The following PROFILE issues were fixed for the 5000.1.2 release.
Description
Version
Comp Level 1
Comp Level 2
726251
Need additional equipment components
supported for certain Section Types
2003.14.1.
0
Well Designer
Wellbore/
Completion
Tab
730570
Depth Reference Datum Shows -0.00ft
Air Gap
2003.14.1.
0
General
731481
Need to be able to include Change
History as a data box in a profile template
2003.16.0.
0
Templates/
Frames
732918
Would like to filter schematic content by
Section & Component type same as
Wellbore Equipment track
2003.16.0.
0
Wall Plot
Composer
733264
No symbol available for solid block xmas
trees - UPDATE: symbols are created need to be put into the install
2003.16.0.
0
Symbols
738481
Incorrect schematic after installing
wellbore equipment components
(transfer)
2003.16.0.
0
Well Designer
741746
Manual text entries being overwritten by
value from picklist
2003.16.0.
1
Well Designer
Wellbore/
Completion
Tab
744640
Chinese Locale: Invoking Event
Properties dialog in FOT/Profile causes
Uncaught Java exception and crash
2003.21.0.
0
Core App
Well Explorer
745088
Casing Design copy from Actual Design
to a different Prototype Design does not
show Casings at the Prototype Design
2003.21.0.
0
Core App
Well Explorer
746242
Need to store the symbol width setting
with a schematic
2003.16.0.
1
Wall Plot
Composer
748665
PROFILE:Casing Jewelry column is not
showing selected fields information. If we
add any field it is showing only blank.
2003.21.0.
0
Wall Plot
Composer
Data Tracks
749429
Stimulation Stage Comments fields is
required for Wall Plot Composer in
PROFILE. Currently there is no way to
see Stimulation Stage Comments in
PROFILE.
2003.21.0.
0
Wall Plot
Composer
Data Tracks
750368
PROFILE - Drillstrings should show Bit
number in assembly spreadsheet.
2003.14.1.
0
Well Designer
Drillstrings/
BHA
5000.1.7
Page 279 of 423
Schematic
Object
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
Version
Comp Level 1
Comp Level 2
726251
Need additional equipment components
supported for certain Section Types
2003.14.1.
0
Well Designer
Wellbore/
Completion
Tab
751122
751122, Request capabilities to auto
calculate Drill Pipe length in PROFILE
Drill strings/BHA spread sheet as
individual BHA Component length is
changed
2003.21.0.
0
Well Designer
Drillstrings/
BHA
751906
Separator Properties has no effect on
Schematic
2003.21.0.
0
Wall Plot
Composer
Data Tracks
751911
Changing Label properties of Line Data
for Plan All Wellbores plot has no effect
on graph and the entered Label is gone
next time the Properties dialog is opened
2003.21.0.
0
Wall Plot
Composer
753100
PROFILE has no default symbols for Adj.
Near Bit Reamer and Core Barrel
2003.21.0.
0
Symbol
Management
753305
In Mapped Symbols Update button does
not call for Save action and hence
Symbols cannot be saved
2003.21.0.
0
Symbol
Management
755539
Live schematic displays differently on
change of active unit system
2003.16.1.
2
Well Designer
756839
Umbilical functionality unstable.
2003.16.1.
2
Well Designer
756880
WPC Schematic Toolbar Problem
2003.21.0.
0
Wall Plot
Composer
757405
Installed Tieback Packer causing design
to become crooked when it is not a dualcompletion
2003.16.0.
2
Well Designer
Interactive
Schematic
757557
Comp Type Code Default Behavior for
Centralizer Jewelry
2003.21.0.
0
Well Designer
Casing Tab
758023
Wall Plot Composer tab: Wellhead
Hangers Data Track is not showing data
for Single Schematic Drawing.It is
showing data only for Wellhead
Schematic Drawing.
2003.21.0.
0
Wall Plot
Composer
Data Tracks
758350
Need a Formations databox in Wall Plot
Composer
2003.16.1.
2
Well Designer
Trajectory Tab
758583
Wrong formation texture being drawn in
WPC
2003.16.1.
2
Well Designer
Trajectory Tab
5000.1.7
Page 280 of 423
Draft
Defect
Symbol
Mappings
Editor
Interactive
Schematic
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
Version
Comp Level 1
Comp Level 2
726251
Need additional equipment components
supported for certain Section Types
2003.14.1.
0
Well Designer
Wellbore/
Completion
Tab
758748
String Component Item Description
created from Catalogue selection does
not include Unit Labels
2003.21.0.
0
Unit
Management
System
759525
PROFILE invalid state This Section >
Total Number of Sections
2003.16.1.
4
Wall Plot
Composer
Schematic
Object
760770
Length from Catalog selection does not
update MD Landed on the fly and
schematics not correct
2003.16.1.
4
Well Designer
Wellbore/
Completion
Tab
762961
Wall Plot Composer Days v. Depth graph
functionality
2003.14.1.
0
Wall Plot
Composer
764203
Need support for BHA Program data box
in Wall Plot Composer
2003.21.0.
0
Wall Plot
Composer
Data Box
Object
764631
Default.ppc Template specifies Drilling on
last day of Completion Event.
2003.16.0.
5
Wall Plot
Composer
Data Box
Object
765894
Component Install Date should default to
the Install Date for the assembly.
2003.21.0.
0
Well Designer
Wellhead Tab
765945
PROFILE does not show the name of the
Drill string/Work String in Data Quality
Date Ranges tab
2003.21.0.
0
Well Designer
Drillstrings/
BHA
767408
Java Exception when trying to copy/paste
PROFILE Template
2003.16.0.
4
Core App
Well Explorer
778782
Enhancements to support StatoilHydro
evaluation of PROFILE.
2003.16.1.
6
Wall Plot
Composer
Schematic
Object
781985
User can not select Zone Name in
Wellbore Openings data box in PROFILE
2003.16.0.
6
Wall Plot
Composer
Data Box
Object
783392
Tubing Hanger Assembly picklists need
to show more description of each
assembly - should list by Assembly Name
(Current Status).
2003.21.0.
1
Well Designer
Wellhead Tab
784439
Well Designer, Well Plot shows
sidetracks not yet kicked off
2003.21.0.
0
Core App
784780
Show Wellbore Properties fields in WPC
Data Box
2003.22.0.
0
Wall Plot
Composer
786799
The top of the casing in the 9 5/8" casing
string below the casing hanger has be
2003.16.1.
8
Well Designer
789647
The cement overlaps the hole and some
of the casing/ casing equipment.
2003.16.1.
8
Symbols
5000.1.7
Page 281 of 423
Data Box
Object
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
Version
Comp Level 1
Comp Level 2
726251
Need additional equipment components
supported for certain Section Types
2003.14.1.
0
Well Designer
Wellbore/
Completion
Tab
790976
PROFILE Stimulation Display Issue
2003.16.0.
1
Core App
Date Bar
792417
Invalid Data QA errors displayed for Hole
Section & Sidetracks due to MD
2003.16.0.
3
Well Designer
Hole Sections
Tab
792937
Comp Group picklist is blank on
Wellheads Tab - PROFILE
PROFILE
5000.1.2.0
Well Designer
793123
Enhancement - Make Section, Township,
and Range available in PROFILE
5000.1.0.0
Wall Plot
Composer
Data Box
Object
793169
Top of cement not correctly showing in
track for 9 5/8" intermediate casing
2003.16.1.
12
Well Designer
Interactive
Schematic
797107
Font colouring is not preserved with
template
2003.16.1.
14
Templates/
Frames
797605
When you attempt to create or load a
workspace prior to setting the workspace
folder you do not get a message and
nothing happens.
5000.1.2.0
Wall Plot
Composer
General Wall
Plot Composer
Functionality
Release 5000.1.1
No additional PROFILE issues were fixed for the 5000.1.1 release.
Release 5000.1.0
The following problems were either fixed or have workarounds for the 5000.1 release.
728578
Performance issue - Lesson Properties
722519
Event Objective 2 in Well Explorer Event Properties dialog is empty
772396
Can not hide the Wall Plot Composer toolbar, deselecting the Wall Plot Composer
toolbar option from View menu is not hiding the WallPlot Composer toolbar and it is
hiding the Schematic Options toolbar.
783711
Easting value is displaying wrong and Longitude value is not displaying in PROFILE,
Well Properties
730571
Blank Datum Elevation Record
771642
Clone of 762750 -PROFILE, custom SI catalogs, column sorting is messed up
783365
Survey data inconsistent between PROFILE and COMPASS applications
5000.1.7
Page 282 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Need to be able to copy and paste components between assemblies
770533
Licensing - EDT software Licensing does not take advantage of the functionality that
will warn users that their license is set to expire in x days
759703
PROFILE software connects Umbilicals to wrong components if Components have
same Item Description; hooking up to Item Description Name and not Id
772693
Output Report preview list on Date Bar displays the incorrect report name
741064
Symbol Map - need to introduce application security token to control access. Most
users will not be customizing Symbol Maps.
723768
Drawings are distorted if repeat symbols have not been defined. Message in Data
Quality window would help with finding this problem.
731492
PROFILE software should report max dogleg, inclination and azimuth in a data box
702512
CD_CEMENT_FLUID data should be available in PROFILE as a track or data box.
731482
Well Status should be available as a data box in PROFILE template
759376
Unable to see data on a custom template for Wellhead data.
758116
Need ability to sort Component Order on Wellbore Equipment Details, Wellhead
Equipment, Casing Assembly Details tables
758114
Unable to remove Time portion of Date/Time Value
758346
Need Cement Slurry Date available in Cementing Databox.
758117
Need Zone, Reservoir and Formation supported in Perforation Intervals data box
777246
Filter out cement that has been drilled out in the cement intervals track
782033
PROFILE software out of memory and poor performance when wellbore openings
overlap
780801
Add TVD Current, Sacks Used, Cement Grade to Data Box
764202
Need support for Mud Program data box in WPC
759908
With large number of Well bore EQs and with the new Split Section feature, opening a
WPC shows the entire Completion assembly instead of X out of Y
771371
WPC tab, Tool Tip text is not displaying for buttons in Schematic Object Properties
dialog.
741749
Need Wellbore Details data table for multi-lateral summary for the Well
740702
OpenWells data missing from PROFILE Data Box & Tracks
742868
Material value in Component Properties not available under Wellbore Equipment
Details
742444
Font scaling problems in wall plots
731557
Need a selection criteria to select only specific items into data boxes e.g. Reference
Datum Boxes
5000.1.7
Page 283 of 423
May 2010
Draft
758680
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
PROFILE software must show wellbore formations and wellbore zones from the
perforation report
732997
Need to be able to specify decimal precision on numeric fields on tracks and data
boxes.
732920
Need ability to group PPC pages into a Template
716527
Component TVDs & Inc not available in WPC Wellbore Equip Assembly Component
Details data box
700055
Need to add support for outputting current date/time to WPC formats
622114
Need WPC data box support for the Well Remarks table
746220
Lithology wont show up unless both top and bottom depth information is entered.
700054
Need the ability to differentiate planned & actual Formations/Lithologies
726272
Need support for completion sub-assemblies
701000
Sub-Assembly Support: need ability to copy other assembly in Design into current
assembly (merge).
755077
Enhance support for Stimulations data
755075
Enhance support for Wellbore Openings
755492
Need to hook Help ID to Assembly Status Dialog topic
755541
Tabs displaying skewed on data box in WPC
758347
WPC Perforations Data Box - Cannot access header fields in master detail
729939
PROFILE software does not handle Depth Correction in Interactive Schematic and
WPC for Casing and Wellbore Equipment's
755062
Support additional Assembly Component fields
751023
Need to segregate Formations by Design
746229
Want to be able to select either prognosed depths or actual depths
749109
Catalog selection windows should be re-sizable
746240
Add the caption label to the tracks listed in the schematic track properties.
743429
Extend PROFILE Actual Design Support to create Report Headers
749109
Catalog selection windows should be re-sizable
746240
Add the caption label to the tracks listed in the schematic track properties.
752498
Umbilicals Component Selection Picklist should show MD Top of each Tool listed for
better differentiation
5000.1.7
Page 284 of 423
May 2010
Draft
728751
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
PROFILE Known Issues
The following PROFILE known issues for releases 5000.1.0 through 5000.1.7 are
described below.
Release 5000.1.7
No additional PROFILE known issues were reported for the 5000.1.7 release.
Release 5000.1.6
Release 5000.1.5
No additional PROFILE known issues were reported for the 5000.1.5 release.
Release 5000.1.4
No additional PROFILE known issues were reported for the 5000.1.4 release.
Release 5000.1.3
No additional PROFILE known issues were reported for the 5000.1.3 release.
Release 5000.1.2
No additional PROFILE known issues were reported for the 5000.1.2 release.
Release 5000.1.1
No additional PROFILE known issues were reported for the 5000.1.1 release.
5000.1.7
Page 285 of 423
May 2010
Draft
No additional PROFILE known issues were reported for the 5000.1.6 release.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.0
The following are PROFILE known issues for the 5000.1 release.
Need support for recording and rendering cellar geometry and schematics for land
wells
750149
Need a comment field for Umbilicals and Jewelry
746244
Long casing components only stretch when the number of joints is 0 or Null.
741740
Need Drag & Drop support for copy/paste of Wellheads between Designs
741741
Perf Status display issue when you have overlapping Perfs
741065
Wellbore Equipment Depths Track should support interpolated inclination and other
directional parameters
741737
Need electronic import support for Surveys
744201
Need WPC template that fits all printers
741750
need spreadsheet import feature same as OpenWells software for Wellbore
Equipment
742088
PROFILE spreadsheets don't support keyboard Delete button or right-click Delete
menu item
781413
Attachments can not Open/Delete/Save As from the Date bar Attachments dialog if we
minimize the ADV.
781410
PROFILE software: Virtual Folder attachments are opened blank.
781521
We can add new Wellbores in PROFILE using Insert key after Revoking
'EDM.Wellbore.add' token also.
776624
OpenWells software vs PROFILE software: ADV, Right click menu item 'Save As' is
always disabled for attachments.
774962
Accessing Properties for the Database node by shortcut key (Alt+Enter) is not working.
778456
change the label "locked" on the Event properties to be consistent with other levels
783972
Launching Help from Sub Assembly button doesn't work properly
783531
PROFILE software, Symbol Manager, Sketch Mode, disable the Options item in View
menu. Currently it is enabled and selecting Options is not showing Options dialog.
782062
Cannot copy a subassembly from one design to another
781965
Drag & Drop vs. Spreadsheet - Deleting rows.
781972
PROFILE software, Hole section, data is not updating properly once it gets dirty with
bad data
5000.1.7
Page 286 of 423
May 2010
Draft
744204
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Real-Time View™ Software
Enhancements
Fixed Issues
Known Issues
The 5000.1.7 release includes all supported platforms, plus enhancements, fixes, and
known issues from the 5000.1.0 and subsequent EDT releases. There were no changes
made to the Real-Time View software for the 5000.1.7 release.
The Real-Time View enhancements and new functionality for releases 5000.1.0 through
5000.1.7 are described below.
Release 5000.1.7
There are no new enhancements to the 5000.1.7 Real-Time View software.
Release 5000.1.6
There are no new enhancements to the 5000.1.6 Real-Time View software.
Release 5000.1.5
There are no new enhancements to the 5000.1.5 Real-Time View software.
Release 5000.1.4
There are no new enhancements to the 5000.1.4 Real-Time View software.
Release 5000.1.3
•
New platforms are supported.
•
Mobile Checkout licensing feature libraries were added.
5000.1.7
Page 287 of 423
May 2010
Draft
Real-Time View Software Enhancements
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.2
For 5000.2 there are no enhancements to the Real-Time View software.
Release 5000.1.1
Release 5000.1.0
The 5000.1.0 release of Engineer’s Desktop supports the Microsoft Vista operating
system, has new LAM (FLEXnet Publisher) licensing and contains some critical bug fixes.
Well Cost was added to the EDT suite of applications for the first time in this release. For
the Real-Time View application, a number of new features were added that include
improved integration with EDT™ software applications through the common Well
Explorer, better access to log curve visualization, and a more streamlined approach to
ASCII and LAS log file import.
•
Well Explorer added to Real-Time View software to enhance usability and leverage
EDT software integration with other drilling applications
•
Drag and Drop individual log curves from the Well Explorer onto the log track in the
log viewing area
•
Logs can be opened, imported, renamed, and deleted from the Well Explorer
•
Added new toolbar buttons
•
Removed some File menu commands
•
Added new View menu command
Additional details follow.
Added the Well Explorer to Real-Time View
Located by default on the left side of the application window, the Well Explorer
functions much like the Microsoft® Windows Explorer. Specifically, it is organized
as a hierarchical data tree, and you can browse the EDM database at seven
5000.1.7
Page 288 of 423
May 2010
Draft
WELLCAT was added to the EDT suite of applications for the first time in the 5000.1.1
release. Also, some Common Well Explorer enhancements were made. (See EDT™
Software for details). This update release improves the import/export and sharing of
Grades, Pipes/Connections between StressCheck and WELLCAT, improves the
integration between StressCheck and WELLCAT, and repairs critical defects affecting
key StressCheck and WELLCAT application functions. There were no additional
enhancements for the Real-Time View software.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
descending levels, though this varies between applications. The Well Explorer
implementation in Real-Time View software exposes logs, and any associated
curves, from the Wellbore level.
Filter
shows currently
selected filter
(notice “funnel”
indicating a filter is
applied to this node)
Currently selected
data item (a Well, in
this example)
Log
Log Curves
Associated Data Viewer
Components “associated
with” the selected data
item (the Well, in this
example). Double-clicking
on Lesson Learned, or
Attachments opens the
respective editor on
demand.
A file or folder
linked to the
selected Well
as an
“attachment”
Figure 1: Well Explorer in Real-Time View
The following special features are associated with the Well Explorer in Real-Time
View software:
•
New icons added for log (
) and log curves (
). Logs can now be opened
by double-clicking on the Log icon in the Well Explorer.
•
Drag and Drop individual log curves onto the log viewing area.
5000.1.7
Page 289 of 423
May 2010
Draft
Hierarchical
“Tree”
Virtual Folder
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
ASCII, LAS (Time), and LAS (Depth) log import from the Wellbore level rightclick menu. The functions are now accessed via context menu commands from
the Well Explorer. For more information, see the “Well Explorer Right-Click
Menus” topic in the online Help for the Real-Time View application.
Import commands from Wellbore
level. Types of log available to
import include ASCII (Time), LAS
(Time), and LAS (Depth).
Draft
Open command from Log level.
Also, the log import menu
commands are shown. The type
of log determines which import
command is enabled. In this
example, the log is LAS depth.
Figure 2: Open and Import Commands Available from Well Explorer
•
Logs can be opened, imported, renamed, and deleted from the Well Explorer
Click here to view a complete description of the EDT 5000.1.0 Well Explorer
enhancements for all EDT applications.
5000.1.7
Page 290 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
New toolbar buttons in the Real-Time View software
Two new buttons were added to the main interface, as seen below.
Open New View - opens
a blank log view pane
View/Hide Well Explorer
- toggles on/off the Well
Explorer
Draft
Figure 3: New Toolbar Buttons
Removed File menu commands
With the addition of the Well Explorer, the following File menu commands were
removed to support a new view/import log workflow from the Well Explorer.
•
Open
•
ASCII Import
•
LAS Import
•
LAS (Depth) Import
5000.1.7
Page 291 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
New View menu command
A new menu command was added to the View menu: Show Well Explorer.
Draft
Show Well Explorer - toggles 
on/off Well Explorer display. This
is the same function as the
toolbar button (
).
Figure 4: New View Menu Command
5000.1.7
Page 292 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Real-Time View Fixed Issues
The Real-Time View issues fixed for 5000.1.0 through 5000.1.7 are described below.
Release 5000.1.7
For 5000.1.6 no Real-Time View software issues were fixed.
Release 5000.1.6
Draft
For 5000.1.6 no Real-Time View software issues were fixed.
Release 5000.1.5
For 5000.1.5 no Real-Time View software issues were fixed.
Release 5000.1.4
For 5000.1.4 no Real-Time View software issues were fixed.
Release 5000.1.3
For 5000.1.3 no Real-Time View software issues were fixed.
Release 5000.1.2
For 5000.1.2 no Real-Time View software issues were fixed.
Release 5000.1.1
For 5000.1.1 no Real-Time View software issues were fixed.
5000.1.7
Page 293 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.0
The following Real-Time View issues were either fixed or have workarounds for the
5000.1.0 release.
Description
720354
If you launch multiple Log Viewer applications from different Daily
Operations in succession, the Log Viewer crashes
720356
Importing multiple logs at the same time to different nodes from multiple or
same instances causes Out of Memory exception
731084
Need to restart the application to view Lessons Learned; Reload Data
does not work
731107
At any given time, if NPT is going on (Nested NPT) and there is no End
specified, Real-Time View Equipment Failure should not show the End
Time as Start Time
731727
Real-Time View software not showing Fluids in Mud Check track from
OpenWire 2003.0.7.1 software
733574
Once curve does not exist in Real-Time View software and corresponding
message is displayed, the same entry should be removed from Recent
Menu list
733575
Track Labels not saved when moving from one Track to another in Track
Parameters
737553
If we create BHA Run and BHA Operation with same Time. The values in
the Real-Time View software are displayed wrong & mixed values.
744271
Help cannot be launched after clicking Help button in Time Shift dialog.
745518
There is a "%d" displayed in Delete confirmation message.
746602
No Help support provided for new Log Editor feature
750757
ALL (ALL Unplanned Operations) is different from All in Time Summary
Filter
751892
File menu Recent list does not show units for Depth-based logs
751975
Provide one message only if data invoked from MRU does not exists any
more
751977
Display text truncated in UI - need to print full name in Curve Display
Parameters for Normal and Symbol
751980
After File Import, Real-Time View software should expand the Well bore
node and put focus on the log that was imported successfully
751981
Real-Time View software won’t show any data if LAS Depth file is
imported again
751992
Need proper error message for LAS Depth Calculation errors
5000.1.7
Page 294 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
752032
Real-Time View software not taking “ARC Gamma Ray, Real-Time” as
Track Label
752051
Real-Time View software vanishes/crashes from screen after importing a
LAS Depth file on top of an ASCII file
752213
Next Day and Last Day buttons still can be clicked when Last Day data is
displayed.
752216
When you select LAS(Depth) Import, LAS(TIME) file can be imported.
752224
ACSII Import help is launched when you click help in LAS file import
window.
753159
Math Calculator doesn't work when input Chinese Description and
Chinese Output name in Function.
753180
There is no relevant help document for Define Data Points Connection in
REal-Time View software.
753182
After inserting, the button should be “Hide” in Define Curve Fills.
753546
Real-Time View software crashes after clicking Delete button in Math
Calculator dialog 3 times.
753550
ASCII(TIME) log file with the invalid date still can be imported in RealTime View software.
753553
After importing an invalid date ASCII file in append mode, the previous
data cannot be displayed normally anymore.
753554
Real-Time View software crashed when select Curve layout after inserting
a row in Horizontal Grid Lines.
753559
There is a minus displayed in the notification when you modify a value in
Horizontal Grid Lines dialog.
753647
Unit is displayed inconsistent in Real-Time View software when SI unit
system selected in Well level.
753668
Unit is displayed truncated in Horizontal Grid Lines dialog.
753874
LAS Depth Files not showing data for a trajectory data LAS file
753877
Default to Screen Settings is always disabled by default in the Set Fonts
properties dialog
753878
Log Curve Labels and Text Track Labels do not have a mechanism to
change Font Colors in Set Fonts dialog; i.e, the entire 'Effects' area is
missing
753880
ASCII (Time) + LAS (Depth) file: Right click Select Curves to Display
crashes the app
753882
Need to warn users if something got changed in template prior to closing
a log
5000.1.7
Page 295 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
753883
Dragging and dropping a track automatically draws grid/border
755143
When cancel to open the second log file, the previous opened log will be
closed automatically.
755145
A series Memory Exception will pop up after doing some operations with
Real-Time View software.
755148
The decimal point is displayed as “.” in the curve in Hungarian OS. (I18NHungarian)
755149
The decimal point “,” cannot be recognized in the imported file. (I18NHungarian)
755778
Real-Time View software will not copy over new files if 2003.21 is installed
on top of 2003.16.1.0 (LAS Depth not possible)
762343
Real-Time View software disappears from screen after opening a specific
LAS file
762344
Real-Time View software does not import a specific ASCII file - Invalid File
Detected
770534
Licensing - EDT software Licensing does not take advantage of the
functionality that will warn users that their license is set to expire in x days
776358
Real-Time View software launches even with no EDM software license
and shows incorrect licensing usage for Real-Time software View licenses
in use and for check out
777164
There are some conflicts in “Math Calculator” chapter of help document.
5000.1.7
Page 296 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Real-Time View Known Issues
The following Real-Time View known issues for releases 5000.1.0 through 5000.1.7 are
described below.
Release 5000.1.7
There are no additional Real-Time View known issues for the 5000.1.7 release.
Release 5000.1.6
Release 5000.1.5
There are no additional Real-Time View known issues for the 5000.1.5 release.
Release 5000.1.4
There are no additional Real-Time View known issues for the 5000.1.4 release.
Release 5000.1.3
There are no additional Real-Time View known issues for the 5000.1.3 release.
Release 5000.1.2
There are no additional Real-Time View known issues for the 5000.1.2 release.
Release 5000.1.1
There are no additional Real-Time View known issues for the 5000.1.1 release.
5000.1.7
Page 297 of 423
May 2010
Draft
There are no additional Real-Time View known issues for the 5000.1.6 release.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.0
The following are Real-Time View known issues for the 5000.1.0 software release.
Description
730561
Bit Op MD value is not being unit converted
750482
The data cannot be displayed with the current Unit in Real-Time View
software after changing the unit in OpenWells software.
750483
Real-Time View software cannot be launched with the current Datum
when launching it via Daily Operations.
751894
Real-Time View software requires better Units support for displaying
depths
753165
Using Real-Time View software after 15-20 minutes, opening a log will
take almost 100% CPU usage
779382
LAS imports always fail because the expected format defined in the
importLAS.ini file is not the same as the file being imported. Need to
proactively inform the user describing why the import failed.
779982
Real Time Viewer, Well Explorer, lock the Properties dialog and move to
next tab and click OK is not locking the Properties dialog.
781757
Missing Search toolbar button in Real-Time View software
782051
Remove Fluids from Associated Data Viewer
5000.1.7
Page 298 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
StressCheck™ Software
Enhancements
Fixed Issues
Known Issues
The 5000.1.7 release includes all 5000.1.3 supported platforms, plus enhancements,
fixes, and known issues from the 5000.1.0 and subsequent EDT releases. Bug fixes were
made to the StressCheck software for the 5000.1.7 release.
The StressCheck enhancements and new functionality for releases 5000.1.0 through
5000.1.7 are described below.
Release 5000.1.7
There are no new enhancements to the 5000.1.7 StressCheck software.
Release 5000.1.6
Workspaces
Workspaces—User and System workspace functionality previously available only
in WELLPLAN has been added to WELLCAT, StressCheck, and CasingSeat. A
workspace is a layout that defines how you want tabs, panes, arrangement of plots
within panes, etc. to appear in the software application.
User and System
Workspaces
5000.1.7
Page 299 of 423
May 2010
Draft
StressCheck Enhancements and New Functionality
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Unlike templates, workspaces do not include data, but only the display
configurations that control the look and feel of the interface.
System Workspaces are read-only, and are shipped with the EDM database. You
may apply them, but not alter them. Additional System workspaces can be
imported using the EDM Administration Utility. When you import System
workspaces, the existing System workspaces are retained.
User Workspaces can be created, changed, or deleted at any time. Importing user
workspaces is an add/replace function; that is, if the name already exists on the
target, the imported workspace will overwrite it.
Figure 1: Differential Pressure Table Example
Switching Between Plots and Tabular Views
Thirteen (13) of the plot views now toggle to tabular view of the data being displayed in
the plot view. To toggle between the plot and tabular views, click the Switch Plot/
5000.1.7
Page 300 of 423
May 2010
Draft
Differential Pressure Table
The Differential Pressures table displays the internal, external and differential
pressure per load case (only burst and collapse load cases) in tabular format.
Differential pressures are defined by the internal and external pressure selected for
each load case. For burst load cases, differential pressure is the difference
between internal and external pressure profiles. For collapse load cases, it is
defined as the difference between external and internal pressure profiles. To
access this table, use View > Tabular Results > Differential Pressures.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Spreadsheet button) located on the Engineering Toolbar. You can also right-click on the
plots and table that support this feature and select Switch.
Draft
Figure 2: Switch Plot/Spreadsheet Button on the Engineering Toolbar
Figure 3: Example of right-click menu containing Switch option to toggle between plot
and tabular views.
5000.1.7
Page 301 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.5
There were no StressCheck enhancements for the 5000.1.5 release.
Release 5000.1.4
There were no StressCheck enhancements for the 5000.1.4 release.
Release 5000.1.3
New platforms are supported.
•
Mobile Checkout licensing feature libraries were added.
Draft
•
Release 5000.1.2
There were no StressCheck enhancements for the 5000.1.2 release.
Release 5000.1.1
WELLCAT was added to the EDT suite of applications for the first time in the 5000.1.1
release. Also, some Common Well Explorer enhancements were made. (See EDT™
Software for details). This update release improves the import/export and sharing of
Grades, Pipes/Connections between StressCheck and WELLCAT, improves the
integration between StressCheck and WELLCAT, and repairs critical defects affecting
key StressCheck and WELLCAT application functions.
Enhanced Integration between StressCheck and WELLCAT software
Enhancements are in the following areas:
•
Fluids
•
Cementing and Landing Data
•
Design Parameters
•
Loads
•
Packers
•
Sharing Pipe and Connection
•
"Save as" Complex WELLCAT Well Configurations
5000.1.7
Page 302 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Tubular Properties
Tubular Properties Import and Export were enhanced to simplify the process of
copying tubular grades, pipes, and connections between the EDM database and
StressCheck or WELLCAT software inventories.
Release 5000.1.0
•
Temperature Deration is now related as a child of Grade in the database. This
accommodates changes to the Temperature Deration schedule for a Grade
without changing the Material.
•
Added Tubular Properties import/export logic, and custom Tubular Properties are
now stored in inventories associated with each Design. Tubular Properties from a
Design can now be exported/imported to the Well Explorer independently or as part
of export/import of 
pipe/connections to catalogs
Temperature Deration
Temperature Deration is now a child of Grade instead of Material, so both Material
and Temperature Deration are children of Grade. This allows changes to the
Temperature Deration schedule for a Grade to be changed without changing the
Material.
Figure 1: Parent-Child Relationship of Grade, Material, Temperature Deration
5000.1.7
Page 303 of 423
May 2010
Draft
The 5000.1.0 release of Engineer’s Desktop supports the Microsoft Vista operating
system, has new LAM (FLEXnet Publisher) licensing and contains some critical bug fixes.
Well Cost™ software was added to the EDT suite of applications for the first time in this
release. For the StressCheck application, the following enhancements were made:
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Import/Export Logic for Grades
The logic used when exporting grades from the inventories to the EDM Tubular
Properties or importing from the EDM Tubular Properties to the inventories has
been enhanced. Also, inventories for Grades, Materials, and Temperature
Deration have been added so that custom Tubular Properties do not clutter up the
EDM database.
The figures below show the full logic applied to import/export of Pipes/Connections
and associated Tubular Properties in several parts. Logic specified with dashed
line borders will be implemented in future releases, but is not included with this
release.
Draft
The operations that employ import/export logic are:
•
Export/Import Strings (Pipe/Casing) and Connections
•
Export/Import Grades, Materials, and Temperature Derations
Exporting/Importing Grades, Materials, and Temperature Derations follows the
same logic as importing/exporting Strings.
Exporting/Importing Materials and Temperature Derations are done by association
while exporting Grades.
Grade, Material, and Temperature Deration inventories are stored under Tubular
menu options per Design so users can create the Tubular Properties in the Design
without affecting common EDM Tubular Properties tables in the Well Explorer.
The logic checks for the existence of the Tubular Properties Name, Grade,
Material, and Temperature Deration (when exporting Grades from inventories to
EDM Tubular Properties, or importing from EDM Tubular Properties to the
inventories). If the Name, Grade, Material, and/or Temperature Deration exist, the
logic prevents creation of duplicates. If the Name, Grade, Material, and/or
Temperature Deration do not exist, the Tubular Properties are created. If the
Tubular Properties Name exists, but the Grade, Material, and/or Temperature
Deration do not match, the export/import operation is stopped.
Check existing Tubular Properties
It is always a good practice prior to exporting/importing a string or
connection, to check the contents of the common Grades/Materials/
Temperature Derations in the Well Explorer and the Design.
5000.1.7
Page 304 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
For a full view of the logic applied to Export to Catalog and Import to Inventory
operations, see the “Import from Catalog Dialog” topic in the Help for the
StressCheck application.
Draft
5000.1.7
Page 305 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Exporting/Importing Strings (Pipe/Casing) and Connections
The following shows a case where the Grade Name exists and Grade Properties
match.
Draft
5000.1.7
Page 306 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Figure 2: Grade Name Exists and Grade Properties Match
The following shows a case where the Grade Name exists but the Grade
Properties do not match. Currently the import/export operation will not occur.
Draft
Figure 3: Grade Name Exists and Grade Properties Do Not Match
5000.1.7
Page 307 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
The following shows a case where the Grade Name does not exist.
Draft
Figure 4: Grade Name Does Not Exist
5000.1.7
Page 308 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
EDT 5000.1 Software Common Well Explorer Enhancements
Click here to view a description of the EDT 5000.1.0 Well Explorer enhancements.
Draft
5000.1.7
Page 309 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
StressCheck Fixed Issues
The StressCheck issues fixed for 5000.1.0 through 5000.1.7 are described below.
Release 5000.1.7
The following issues were either fixed or have workarounds for the 5000.1.7 release.
Description
829500
Different results when DLS Overrides and Wellpath Editor DLS are equal.
832318
Allow user to launch Catalog Editor while applying Catalog Editor import
token.
833335
Cannot export Designs to StressCheck files with double quotes in the
name.
833336
Incorrect Poisson’s absolute maximum allowable value.
833939
Save button does not become active after deleting a row in an input
spreadsheet.
834023
When planning a U-shaped well, it was noticed that the Pore, Fracture &
MW Plot was giving an incorrect result.
834024
StressCheck Design export—transfer file can fail to receive the .XML file
extension.
Release 5000.1.6
The following issues were either fixed or have workarounds for the 5000.1.5.1 release
(includes fixes from the 5000.1.5.1 patch release).
Defect No.
Description
819187
StressCheck fails to launch/display no valid license message with expired
bitlock/node-locked license file.
820942
SC crashes with no error because an empty custom load has been left
active when the design was closed.
829489
Burst/Collapse plots partially displayed and incorrect properties dialog
don’t allow access to data selection dialog.
819671
StressCheck Normalized Minimum Safety Factor plot does not match
values. (Fixed in 5000.1.5.1)
821779
StressCheck displays unsupported Section Type error and prevents
Save. (Fixed in 5000.1.5.1)
5000.1.7
Page 310 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Defect No.
Description
822144
Triaxial Safety Factor Plot displays normalized safety factors
by design, however the toggle button to display absolute safety
factors is enabled. (Fixed in 5000.1.5.1)
Release 5000.1.5
The following issues were fixed for the 5000.1.5 release of StressCheck software.
Description
729224
Wall Plot Composer - change Wall Plot Composer menu item names to be
consistent with Plot dropdown names
729247
Wall Plot Composer - remove ability to delete wall plot objects with Edit > Delete
Row command
730994
Design Limits Plot - only one section of multi-section strings prints
730996
Von Mises Equivalent Stress Plot - only one section of multi-section strings prints
741615
Convert Depth - keyboard input of the decimal point not accepted
741927
Classic Well Schematic - the schematic image can overlap into the title bar area
751255
Design Limit Plot - unexpected X and Y graph scale units
775752
Design Limits Plot - re-scales and changes the X and Y ranges
789064
Von Mises Equivalent Stress Plot - unexpected X and Y graph scale units
798125
Incorrect Maximum Anticipated Surface Pressure (MASP) Calculation with Two
Production Liners
812111
Inconsistent behavior of unit conversion dialog box in StressCheck
812117
Unit conversion dialog box - incorrect values display after selecting the Cancel
button.
812126
Cannot delete the last tab in a StressCheck template.
813157
Wall Plot Composer - Refreshing issue when switching from a StressCheck design
tab to the Wall Plot tab
813988
Wellbore > General dialog - some static fields are not long enough to display the
'usft' unit label
816359
Spikes appear in Triaxial Safety Factors view due to incorrect Minimum Safety
Factors.
817326
Wall Plot Composer - unit not shown on X & Y axis for all Design plots.
5000.1.7
Page 311 of 423
Draft
Defect No.
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.4
The following issues were either fixed or have workarounds for the 5000.1.2 release.
Description
772809
Modify StressCheck template to allow selecting pore and frac tables in
read-only mode.
810192
Invalid argument while opening a design created in StressCheck
2003.16.1.X.
810193
Frac Margin of Error becoming read-only.
810194
Curves missing in Triaxial Safety Factors for a specific pipe.
810410
Memory leak associated with safety factor calculations.
810430
StressCheck crashes while importing wellpath in a tab-delimited
document.
811170
On Temperature Deration Help topic, indicate how temperature deration
is used.
Draft
Defect No.
Release 5000.1.3
No additional StressCheck issues have been fixed for the 5000.1.3 release.
Release 5000.1.2
The following issues were either fixed or have workarounds for the 5000.1.2 release.
Defect No.
Description
796019
Problem with the Axial Force Apparent w/Bending calculation for
the negative neutral point depth row in Triaxial Results.
796897
String Section data in some older SCK files can become corrupted
after saving to EDM.
797343
Tool passage report "force required to pass" in a scenario where
it is not applicable.
797976
Problem with the Axial Force Apparent w/Bending calculation for the
negative neutral point depth row in Triaxial Results.
797978
String Section data in some older SCK files can become corrupted after
saving to EDM.
797979
Tool passage report "force required to pass" in a scenario where it is not
applicable.
5000.1.7
Page 312 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.1
The following issues were either fixed or have workarounds for the 5000.1.1 release.
Description
762571
StressCheck Permeable Zones Issue
775741
The default value for MW for the next hole section for DrillAhead. Burst
load case is incorrect.
775742
The default value for MW for the next hole section for DrillAhead. Collapse
load case is incorrect.
775743
MMS report field can be overwritten as indicated in the help, but when the
report is printed the report is regenerated to give default values for certain
fields.
775753
The default value for max mud weight for gas kick load case should
change according to the influx depth value.
775971
Changing mud weight in Casing Scheme doesn't automatically change
the default values for mud weights in external pressure profile such as
"Fluid Gradients with pore pressure" for both burst and Collapse load
cases.
784533
License Failure Message - Update the version number in the title bar to
5000.1.0.0
786273
All Depth-related Plot Views - Vertical axis depth label does not change
when toggling from MD mode to TVD mode.
787667
Difference in SF results observed if the well schematic or other plots are
toggled from MD to TVD.
787915
Uncaught Java Exception when opening a Design, mentioning
convertYTrueToGridNorth, followed by a crash.
788403
StressCheck checks out an EDM license when other EDT apps already
have a license checked out.
Release 5000.1.0
The following issues were either fixed or have workarounds for the 5000.1.0 release.
Defect No.
Description
720091
A second pipe catalog with same Properties as the API Casing/Tubing
catalog does not appear as expected in the Import from Catalog dialog.
5000.1.7
Page 313 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
750190
Need to have a global inventory (no editable by Engineer in the Business
Unit except EPTG Engineers with the right access. This include pipe
inventory or pipe catalog, as wells as grades and associated tables
(material, deration).
754023
Cannot change grades when the first four symbols are the same, i.e. C110_IMP cannot be changed to C-110.
754067
File Import (SCK file) does not respect EDM security
755499
Pressure test = Pressure test Axial Safety factor in 16.1.1.(2) does not
match 2000. Max dogleg is not applied in calculations.
756244
The triaxial results still does not match the issue is at below TOC depth.
Apparently 2000 is correct. In 2000 there is a discontinuity at 1948 in axial
load for 20" surface casing
756355
A vertical well in StressCheck 2000 software does not apply the maximum
dog leg that version 2003.16.1 applies. Once max dogleg is removed, SF
matches between the StressCheck 2000 and 2003.16.1.1 software
versions.
756651
Difference in Lowest axial safety factor reported between StressCheck
software version 2000 and 2003.16.1
756663
After import SCK file it shows that “Shut in” is checked to be use in
Collapse Calculation and “Evacuate” is checked for burst calculation
756984
The addition of an extra row in survey editor causes all min. safety factors
to not match between builds
757903
Incorrect default temperature profile in 16.1 for lost return with mud drop
scenario
758299
StressCheck 2000 software version vertical well is shown as a deviated
well in version 2003.16.1. Once the wellpath definition is the same in both
versions, the results match.
760856
Pipe with wall thickness other than 87.5% are imported with the wall
thickness field blank
762289
EDM 2003.16.1.4 software Custom Loads Pressure Issue - Save as
764307
Copy and paste from Excel to the Material Table
764309
System Template export function failed
764887
WELLPLAN software User Defined WorkSpace VS StressCheck software
User Defined Template
766440
Save As of the Design crashes the application.
766929
Imported special pipe from catalog is not honored in StressCheck
software
5000.1.7
Page 314 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
768241
Datum Shifts - Slant Well Behavior - Design incorrectly opens at a new
datum although a warning correctly tells the user that the Design can be
opened at the original datum only.
770535
Licensing - EDT software Licensing does not take advantage of the
functionality that will warn users that their license is set to expire in x days
775238
Differences in Min Safety Factors
780524
Inconsistency of Triaxial Graphs and results
781055
Connection table: Connection safety factor only reports the lowest safety
factor in tension while the String summary table reports the absolute
lowest safety factor (from tension and compression).
781893
Application does not refresh imported special connections in connection
pick list. User has to refresh the views to make available recently
imported special connection
781895
StressCheck software does not refresh results while changing tubular
properties
783023
Save As is very slow in StressCheck software
5000.1.7
Page 315 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
StressCheck Known Issues
The following StressCheck known issues for releases 5000.1.0 through 5000.1.7 are
described below.
Release 5000.1.7
The following are StressCheck known issues for the 5000.1.7 release.
Description
831086
StressCheck Collapse Load (full/partial evac) changes significantly with
mud depth change.
834385
StressCheck Detailed report creation failure “Cropping”.
Release 5000.1.6
The following are StressCheck known issues for the 5000.1.6 release.
Defect No.
Description
829500
Different results when the DLS Overrides and Wellpath Editor DLS are
equal
831086
StressCheck Collapse Load (full/partial evac) changes significantly with
mud depth change
Release 5000.1.5
The following are StressCheck known issues for the 5000.1.5 release.
Defect No.
Description
802420
Casings, liners and tie-backs are re-sorted (in the wrong order) in the
StressCheck application when surveys are changed / replaced in
COMPASS software.
809961
Stresscheck Error - Currently selected Design Datum is different than the
datum used to store data in version 2003.1.21.04
812133
The service load profile in the axial loads plot doesn't seem to be following
the correct trends.
812134
User can modify tab information even if they are locked.
813596
StressCheck is reporting different results on the detailed and summary
pages of specific dataset
5000.1.7
Page 316 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Defect No.
Description
816537
StressCheck Design takes too long to save when doing a Save As.
Release 5000.1.4
There are no additional StressCheck known issues for the 5000.1.4 release.
Release 5000.1.3
Draft
There are no additional StressCheck known issues for the 5000.1.3 release.
Release 5000.1.2
There are no additional StressCheck known issues for the 5000.1.2 release.
Release 5000.1.1
The following are StressCheck known issues for the 5000.1.1 release (build 1937).
Defect No.
Description
730994
Design Limits Plot: Only one section of multi-section strings is printed.
730996
Von Mises Equivalent Stress Plot: Only one section of multi-section
strings is printed.
741615
Convert Depth: Keyboard input of the decimal point is not accepted.
741620
Convert Units: The unit “ft” is displayed three times in the dialog.
747744
Internationalization: Correct delimiter is not immediately displayed in the
plot and spreadsheet views. Possible refresh issue.
748933
Casing and Tubing Scheme spreadsheet: Inputs into the Shoe Depth,
TOC Depth, and MW at Shoe fields are not “accepted” until the user
switches
tabs.
751255
Ellipse graph tries to change graph scales. Right click for properties, the
graph scale ranges are in wrong units (both X & Y axes are in “ft”
instead of kip and psi).
753096
Copy casing assemblies or tubing assemblies from a source Design to a
target “Opened Design” does not display the pasted assemblies unless
the targeted
Design is closed and reopened.
5000.1.7
Page 317 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
757716
Pressure test load calculation is incorrect when applying plug option.
769221
Well Schematic does not generate until the user deliberately re-selects it
from the menu when running StressCheck software on Microsoft Vista.
773271
Differences in one of the depth in Collapse Load - Temperature Tab.
775752
Design Limits plot re-scales and changes the X and Y ranges.
775965
The default value for “Pore Pressure @ Lost Returns Depth” in “Lost
Returnswith Mud Drop” collapse load case does not refresh in certain
scenarios when the lost returns depth is changed.
776902
The border size in the Well Schematic shows twice the size of the
previous release in the CasingSeat and StressCheck applications.
778537
Print Preview of Wall Plot does not display XY plot correctly.
778928
When you freeze a line, then change the current string, the legend and
plot still shows the line.
781646
Wall Plot Composer template does not update when changing current
string.
783811
Citrix - Intermittent “Memory could not be read” error.
Release 5000.1.0
The following are StressCheck known issues for the 5000.1.0 release.
Defect No.
Description
730994
Design Limits Plot: Only one section of multi-section strings is printed.
730996
Von Mises Equivalent Stress Plot: Only one section of multi-section
strings is printed.
741615
Convert Depth: Keyboard input of the decimal point is not accepted.
741620
Convert Units: The unit “ft” is displayed three times in the dialog.
747744
Internationalization: Correct delimiter is not immediately displayed in the
plot and spreadsheet views. Possible refresh issue.
748933
Casing and Tubing Scheme spreadsheet: Inputs into the Shoe Depth,
TOC Depth, and MW at Shoe fields are not “accepted” until the user
switches tabs.
751255
Ellipse graph tries to change graph scales. Right click for properties, the
graph scale ranges are in wrong units (both X & Y axes are in “ft” instead
of kip and psi).
5000.1.7
Page 318 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
753096
Copy casing assemblies or tubing assemblies from a source Design to a
target “Opened Design” does not display the pasted assemblies unless
the targeted Design is closed and reopened.
757716
Pressure test load calculation is incorrect when applying plug option.
762571
StressCheck software Permeable Zones issue where Burst design load
line does not appear to be correct.
769221
Well Schematic does not generate until the user deliberately re-selects it
from the menu when running StressCheck software on Microsoft Vista.
772411
Additional filters are required while exporting importing tubular properties/
pipe and connections.
773271
Differences in one of the depth in Collapse Load - Temperature Tab.
775741
The default value for MW for the next hole section for DrillAhead Burst
load case is incorrect.
775742
The default value for MW for the next hole section for DrillAhead Collapse
load case is incorrect.
775743
MMS report field can be overwritten as indicated in the help, but when the
report is printed the report is regenerated to give default values for certain
fields.
775752
Design Limits plot re-scales and changes the X and Y ranges.
775753
The default value for max mud weight for gas kick load case should
change according to the influx depth value.
775965
The default value for “Pore Pressure @ Lost Returns Depth” in “Lost
Returns with Mud Drop” collapse load case does not refresh in certain
scenarios when the lost returns depth is changed.
775971
Changing mud weight in Casing Scheme does not automatically change
the default values for mud weights in external pressure profile such as
“Fluid Gradients with Pore pressure” for burst and collapse load cases.
776902
The border size in the Well Schematic shows twice the size of the
previous release in the CasingSeat and StressCheck applications.
778248
When entering too large a pipe OD, an error message for Gas Kick Profile
is properly received. However, the error message is still received after
deactivating the Gas Kick Profile option.
778359
Defaults design factors not recognized in Design Parameters.
778537
Print Preview of Wall Plot does not display XY plot correctly.
778928
When you freeze a line, then change the current string, the legend and
plot still shows the line.
781646
Wall Plot Composer template does not update when changing current
string.
5000.1.7
Page 319 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Defect No.
Description
783811
Citrix - Intermittent “Memory could not be read” error
Draft
5000.1.7
Page 320 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WELLCAT™ Software
Enhancements
Fixed Issues
Known Issues
The 5000.1.7 release includes all 5000.1.3 supported platforms, plus enhancements,
fixes, and known issues from the 5000.1.0 and subsequent EDT releases. Bug fixes were
made to the WELLCAT software for the 5000.1.7 release.
The WELLCAT enhancements and new functionality for releases 5000.1.0 through
5000.1.7 are described below. Also described are enhancements added in the
2003.21.1.0 limited release that were rolled into the 5000.1.1 release.
Release 5000.1.7
There are no new enhancements to the 5000.1.7 WELLCAT software.
Release 5000.1.6
Workspaces
Workspaces—User and System workspace functionality previously available only
in WELLPLAN has been added to WELLCAT, StressCheck, and CasingSeat. A
workspace is a layout that defines how you want tabs, panes, arrangement of plots
within panes, etc. to appear in the software application.
User and System
Workspaces
5000.1.7
Page 321 of 423
May 2010
Draft
WELLCAT Enhancements and New Functionality
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Unlike templates, workspaces do not include data, but only the display
configurations that control the look and feel of the interface.
System Workspaces are read-only, and are shipped with the EDM database. You
may apply them, but not alter them. Additional System workspaces can be
imported using the EDM Administration Utility. When you import System
workspaces, the existing System workspaces are retained.
User Workspaces can be created, changed, or deleted at any time. Importing user
workspaces is an add/replace function; that is, if the name already exists on the
target, the imported workspace will overwrite it.
5000.1.7
Page 322 of 423
May 2010
Draft
Packer Envelope
It is now possible to define, apply and save a packer operating envelope using the
WELLCAT™ Tube module. The packer operating envelope is defined using the
Operating Envelope tab on the Packer Details dialog. The packer envelope can be
viewed using the Packer Operating Envelope plot. Access this plot using Results
> Multiple Loads > Packer Operating Envelope.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Every packer has an operating envelope based on vendor specifications. Packers
are rated in terms of annular pressure differential across the packer, and load
transfer from the tubing to the packer. In well completion configurations, packers
are exposed to temperature and pressure loading conditions. These loading
conditions may fall outside of the vendor specified packer operating envelope.
Draft
5000.1.7
Page 323 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Figure 1: Packer Operating Envelope Example (Packer Details dialog)
Minimum Safety Factor Table
The Minimum Safety Factors table displays minimum safety factors as a function
of depth for all sections of the currently selected string. For any depth displayed,
the burst, collapse, axial, and triaxial safety factors shown represent the minimum
5000.1.7
Page 324 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
safety factor for all load cases. To access this table, use Results > Summaries >
Minimum Safety Factor. This functionality is available in the Casing, Tube, and
MultiString modules.
Draft
Figure 2: Minimum Safety Factor Table Example
5000.1.7
Page 325 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Cementing
To meet the requirements of today’s cementing operations, the WELLCAT
software can now model more complex cement job descriptions that include
multiple spacers and displacement fluids, multiple slurries and rates, as well as
elapse shut in time, and heat of hydration rates per slurry.
Draft
Figure 3: Primary Cementing tab for Complex Cement jobs
5000.1.7
Page 326 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Steam Circulation
It is now possible to circulate steam (wet or dry) while analyzing production tubing
or workstring operations using the Prod module. Both forward and reverse
circulation can be modeled. All appropriate single, multiple, and summary
circulation results will display results for the steam circulation. A separate license
feature (WELLCAT_STEAM) is required to access this functionality.
Draft
Figure 4: Steam Circulation Results Example
Release 5000.1.5
In this release, extended support to handle densities, pressures and temperatures
from Prod to Casing Custom Loads in Tubing Less Scenarios was added to
WELLCAT.
This enhancement supports sharing densities, pressures and temperatures between
Prod simulations and Casing Custom Loads for Tubing less monobore and non
monobore configurations.
5000.1.7
Page 327 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.4
There were no WELLCAT enhancements for the 5000.1.4 release.
Release 5000.1.3
•
New platforms are supported.
•
Mobile Checkout licensing feature libraries were added.
Draft
Release 5000.1.2
There were no WELLCAT enhancements for the 5000.1.2 release.
Release 5000.1.1
WELLCAT was added to the EDT suite of applications for the first time in the 5000.1.1
release. Also, some Common Well Explorer enhancements were made. (See EDT™
Software for details). This update release improves the import/export and sharing of
Grades, Pipes/Connections between StressCheck and WELLCAT, improves the
integration between StressCheck and WELLCAT, and repairs critical defects affecting
key StressCheck and WELLCAT application functions. It also includes enhancements
and bug fixes from the 2003.21.1.0 release (a limited release).
Enhanced Tubular Properties Import and Export
To simplify the process of copying tubular grades and related properties between
the EDM database and WELLCAT inventories, a wizard has been developed. The
wizard employs a logical set of rules when importing and exporting grades, pipes,
and connections to preserve the integrity between tubular properties inventories
and EDM tubular properties and to prevent mismatches.
Specifically, the logic checks for the existence of the Tubular Properties Name,
Grade, Material, and Temperature Deration (when exporting Grades from
inventories to EDM Tubular Properties, or importing from EDM Tubular Properties
to the inventories). If the Name, Grade, Material, and/or Temperature Deration
exist, the logic prevents creation of duplicates. If the Name, Grade, Material, and/
or Temperature Deration do not exist, the Tubular Properties are created. If the
Tubular Properties Name exists, but the Grade, Material, and/or Temperature
Deration detailed properties do not match, the Import/Export Wizard opens. Refer
to the online help for more information.
5000.1.7
Page 328 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Additionally, WELLCAT software examines other material properties when
checking grades (Young’s Modulus, UTS, Poisson's Ratio). If there is a mismatch
between EDM Tubular Properties and the Design’s Tubular Properties Inventory,
the WELLCAT software import/export operation may not occur. For example, if two
or more grades are exported that use the same material, but the material properties
of Young’s Modulus, UTS, and/or Poisson's Ratio mismatch, the import/export
operation is skipped. For additional information, refer to Exporting and Importing
Grade, Pipe, and Pipe With Connections Between WELLCAT and EDM in the
WELLCAT online help.
Enhanced Integration Between StressCheck and WELLCAT Software in the
following areas:
All software included in the Engineer's Desktop Drilling Applications share data
stored in the EDM Database. In addition to this shared data, the integration and
data sharing between the WELLCAT and StressCheck software has been
enhanced in the following areas. For additional details, please refer to the
StressCheck/WELLCAT section in the online help Table of Contents.
•
Fluids: The sharing of fluid density is bi-directional between the WELLCAT and
StressCheck software. Therefore, a change to fluid density made by either
software will be visible in the other software. When a Design created by the
StressCheck software is opened using the WELLCAT software, default fluid
names and rheological properties are assigned based on the fluid type (mud or
cement). (Because the StressCheck software does not support rheological
properties or fluid names, this data cannot be shared between the applications.)
•
Cementing and Landing Data: The following data is shared bi-directionally
between WELLCAT and StressCheck software.
—
—
—
—
—
—
—
—
—
—
5000.1.7
Mix water density
Lead slurry density
Tail slurry density
Tail slurry length
Displacement fluid density
Applied surface pressure
Float failed check box indicator
Pickup force
Slackoff force
Initial conditions temperature profile data 
Page 329 of 423
May 2010
Draft
For a flowchart of the import and export procedure, refer to Import/Export Logic for
Grades on page 304.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
Design Parameters: All design parameters are shared bi-directionally between
WELLCAT and StressCheck software. The only Design Parameter Analysis
Option shared between WELLCAT and StressCheck software is the
Temperature Deration option.
•
Loads: The following is a brief summary of load sharing between the
StressCheck and WELLCAT software. For more information, refer to the Load
Integration Between WELLCAT and StressCheck, or the Integrated Load Data
topics in the online help.
If a Design is created using StressCheck software, several burst, collapse, and
axial loads for casing and tubing created by StressCheck software are shared
with WELLCAT software. However, any subsequent changes made to the
shared loads by either application will not be reflected in the other application.
The following loads are shared from StressCheck to the WELLCAT software:
Burst Loads:
—
—
—
—
—
Displacement to Gas (Casing, Liner)
Gas Kick Profile (Casing, Liner)
Lost Returns with Water (Casing, Liner)
Surface Protection (BOP) (Casing)
Pressure Test (Casing, Liner, Tubing)
Collapse Loads:
— Full/Partial Evacuation (Casing, Liner, Tubing)
— Lost Returns with Mud Drop (Casing, Liner)
— Annular Pressure Test (Tubing)
Axial Loads:
— Overpull Force (Casing, Liner, Tubing)
— Running in Hole (Casing, Liner, Tubing)
— Green Cement Pressure Test (Casing, Liner)
External Pressure Profiles:
— Mud and Cement Mix Water
5000.1.7
Page 330 of 423
May 2010
Draft
Sharing of load data is “one-way” only from the StressCheck software to the
WELLCAT software. If a Design is created using WELLCAT software, none of
the loads created using WELLCAT software are available to StressCheck
software.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
—
—
—
—
—
Permeable Zones
Minimum Formation Pore Pressure
Above/Below Prior Shoe
Pore Pressure with Seawater Gradient
Fluid Gradients with Pore Pressure (Although this profile is common to
both WELLCAT and StressCheck software, the calculation methodology
differs.)
— Mud and Cement Slurry
— Mud and Cement Mix-Water
Packers: The sharing of packer data is “one-way” only - from StressCheck
software to WELLCAT software, but only the first time you open the design
using WELLCAT software. When using StressCheck software, packers are
defined by default for tubing strings. This packer will be available to the
WELLCAT software the first time a design created using StressCheck software
is opened using WELLCAT software. If WELLCAT software was used to enter
or edit a packer, that packer information is not available in StressCheck
software.
•
Pipes, and Connections: Tubular applications (StressCheck and WELLCAT)
do not share Pipe/Connection Inventories or Tubular Properties. In order to
work on the same Design with both tubular applications, always synchronize
inventories using the export to catalog feature. Designs that contain pipes and
connections, or partially defined pipe and connection properties with no
common tubular properties, that are opened by another tubular application but
do not exist in the Design's inventories and EDM database, exhibit certain
conditions. Refer to Sharing Pipes and Connections Across Tubular
Applications in the online help for more information.
•
“Save As” Complex WELLCAT Well Configurations: To protect WELLCAT
complex Well Configuration designs that include complex string type
configurations, VIT (Vacuum Insulated Tubing), Dual Completions, Scab Liner,
Tieback to Tieback, Tieback to Casing, Tiebacks on TLP Well Configurations,
LIP (Liner Isolation Packer), and ISO Connections, StressCheck software user
is limited to “Save As” these Designs. However, the user is allowed to perform
modifications and “Save As” these Designs to be valid in StressCheck.
DeepWater and Steam License Check Out
License check-out for DeepWater and Steam functionality was modified. If an
available license exists, it will be checked out when the license is required to
perform specific functionality. In the past, a license was automatically checked out
when the WELLCAT software was opened.
5000.1.7
Page 331 of 423
May 2010
Draft
•
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Improved, Default, Minimum, and Maximum Values Implemented for Casing Loads
Improved default values, as well as minimum and maximum input data ranges,
were implemented for several data fields associated with four casing loads
(Displacement to Gas, Gas Kick, Lost Returns with Water and Lost Return With
Mud Drop) available in the Casing module.
When WCD files generated using previous versions of WELLCAT software are
opened using WELLCAT software version 5000.1.1:
User entered values for these loads input in the previous version will be
honored.
•
New default, minimum, and maximum values will be replace the previous
defaults used in prior releases.
•
Results may change after you recalculate using the new defaults.
Engineering Enhancements Rolled into 5000.1.1 From the 2003.21.1.0 Release
VIT Tubing
It is now possible to define VIT tubing in the new VIT Tubing Pipe Inventory and
then use the tubing in the wellbore configuration by selecting in on the Casing and
Tubing Configuration Spreadsheet. To model VIT tubing in previous versions of
WELLCAT, it was necessary to create a composite string with an OD equivalent to
the outside diameter of the VIT tubing, ID equivalent to the inside diameter of the
tubing, and weight representative of the overall VIT tubing (outer and inner pipes,
plus insulation).
With this release, the definition of VIT has been streamlined. Using the VIT Tubing
Pipe Inventory, the proper geometry, weight, and grade for both the inner and outer
pipes, as well as the location of the connection in the VIT can be specified. In
addition, the overall thermal properties (k-value) can be specified for both tubing
and connection(s).
For information on VIT tubing, including analysis assumptions, calculations, and
references, please refer to VIT Tubing topic in the online help.
Notes:
•
VIT can be used as part of a dual tubing configuration for stress analysis in the
Tube module.
•
VIT Tubing Pipe Inventory - Use the VIT Tubing Inventory spreadsheet to define
the available VIT tubing. The VIT tubing is created using the standard pipe and
grade inventories. All VIT tubing defined in this spreadsheet can be used as
5000.1.7
Page 332 of 423
May 2010
Draft
•
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
part of the tubing defined in the well configuration by selecting it on the Casing
and Tubing Configuration Spreadsheet. For more information, refer to the VIT
Tubing Pipe Inventory topic in the online help.
•
Well Schematic - VIT tubing can be displayed on the Well Schematic. To
display the VIT Tubing, click the VIT box on the Well Schematic Properties
Dialog.
Casing With Stabilization (Centralizer)
Buckling represents a string movement resulting from a combination of mechanical
forces and pressure induced forces. Because centralizers placed along the string
impact the string movement, the position of the string in the wellbore, and therefore
the contact points between the string and the wellbore, their placement also impact
buckling.
Centralizers impact the analysis in the following ways:
•
The weight of the centralizer has been included in the axial force calculations
and the contact force calculations.
•
The effect of the “springy-ness” of bowed centralizers has been included to
increase the contact force in stress calculations, as well as for tubing movement
calculations.
•
A minimum radial clearance is determined for centralized tubing. This radial
clearance is used for buckling calculations for stabilized pipe, including buckling
length change and contact force.
•
Friction forces may be different for centralizers compared to bare pipe. The user
can input a scaling factor (for rigid centralizers only) to modify the nominal
friction value for the stabilized pipe intervals.
Centralizers can be manually entered into the Centralizer dialog, or they can be
imported from the Centralizer Catalog. Use the Centralizers dialog to specify the
location of the centralizers. Using the Centralizers dialog, you can define the
5000.1.7
Page 333 of 423
May 2010
Draft
Multiple Hanger Depths
To improve thermal modeling of subsea well configurations, up to 20 hanger
depths can be modeled. Once the proper temperatures have been determined,
thermal and flow analysis results are presented in tabular form in reference to each
string hanger depth. Further analysis, such as Annular Fluid Expansion Wellhead
Movement can be performed. Be aware that multiple hanger depths can be
specified for TLP wells, however this will result in the loss of some TLP analysis
options because TLP analysis expects one common hanger depth.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
interval containing centralizers by specifying the start and end distance from the
casing shoe depth, and then specify the number of centralizers per joint. It is not
necessary to specify each centralizer separately.
Using Prod Operations for Casing Custom Loads
Production operations can cause loads to the casings. It is now possible to select
a Prod load to map temperatures and density/pressure profiles for a Custom
Casing Load.
If You Select a Prod Operation:
The annular fluid content for the casing being analyzed (current string) is based
on entries in the Casing and Tubing Configuration Spreadsheet and Annulus
Contents Spreadsheet, including any gas intervals, or un-cemented intervals.
— Cemented intervals will be assumed to be set cement, and the mix-water
density will be used.
— The Annulus Fluid density will be used in un-cemented intervals. 
•
The internal fluid content for the casing being analyzed is based on:
— The annular fluid content for the casing inside the casing being
analyzed.
— Cemented intervals will be assumed to be set cement, and the mix-water
density will be used.
— If there is tubing inside the casing being analyzed, the internal contents
are based on the Prod load selected.
Hanger Lift Off In Wellhead Movement Analysis
WELLCAT Wellhead Movement Analysis has been enhanced to account for lockrings, lift-off analysis, point of fixity, and load compensators. Use the Installation
and Static Load Definition dialog to specify the parameters associated with these
items.
Point of Fixity
This is the depth below which the selected outermost string has zero displacement,
and is in full contact with the formation or cement. By default, the point of fixity is
assumed to be at the mudline for drive pipe. For other internal strings selected to
be the Outermost string, the point of fixity is assumed to be the top-of-cement as
indicated on the Casing and Tubing Configuration Spreadsheet.
5000.1.7
Page 334 of 423
May 2010
Draft
•
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Using this option to change the point of fixity, you can quickly evaluate the effect
that altering the point of fixity has on wellhead movement load and displacement
analysis without recalculating the thermal loads.
Note: If you change the point of fixity, the thermal loads will still reference the
original point of fixity (mudline for drive pipe, or TOC for internal strings).
If you have checked the Soil-Interaction Model box on the Calculate Multax dialog,
the point of fixity is not applicable.
For a comprehensive analysis, specify a lock-ring rating for each string as part of
the wellhead.
If the Lock-Ring Rating box on the Installation and Static Load Definition dialog is
not checked, this comparison is still performed to report conditions in which the
contact forces exceed the lock-ring rating. However, progressive failure analysis
will not be done unless the Lift-Off box is checked.
Lock-Ring Rating
Lock-rings are intended to help keep a slip assembly together. A lock-ring allows
negative contact forces within a slip, up to the lock-ring rating limit. Thus, in the
progressive failure analysis (see Lift-Off), the contact force + lock-ring rating is the
criterion for failure, rather than simply the contact force. Default values for lock-ring
rating are zero.
The rating corresponds to the highlighted string in the Strings list on this dialog. The
lock-ring is applied between the selected string, and the next outer string. This field
is only enabled when the outer-most string is not selected (highlighted) in the
Strings list.
Inner String Cementing
WELLCAT has been enhanced to allow for cementing operations where a small
diameter drillpipe or stringer set-up is used to convey cementing fluids within a
large diameter casing. Inner string cementing allows for faster pumping times, and
5000.1.7
Page 335 of 423
May 2010
Draft
Lift-Off
This option performs a progressive failure analysis. In this analysis, slips with
negative contact force between strings are assumed to come apart. When lockrings are present, a negative value for contact force + lock ring rating is used as
the failure criterion (See Lock-Ring Rating). The program finds the worst case
negative failure criterion and recalculates the wellbore loads assuming no contact
at that point. The process continues until there are no failure points remaining.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
potentially smaller pumping displacement volumes down the inner string when
compared to pumping down a large diameter casing. Inner string cementing
functionality within WELLCAT is intended to predict the temperatures, pressures,
and densities of flowing cement during an inner string cementing job of casing and
tiebacks. This functionality is not intended to be used to model running casing, or
to model inner string cementing for liners or scab liners. Refer to the Inner String
Cementing help topic in the online help for more information.
Load envelopes for the ISO connection selected in the String Sections are
automatically displayed in the Design Limits plot. Other envelopes can also be
displayed on the Design Limits Plot for comparison. See the Design Limits Plot, or
ISO Service Load Test Data Dialog help topics in the online help for more
information.
Multiple Packer Setting Sequences
In addition to traditionally setting packers from the deepest to shallowest depth,
packers can now be set in any order. Refer to the Packers Dialog help topic for
more information.
Hydrostatically Set Packers
Hydrostatically set packers can now be used in WELLCAT. A hydrostatic set
packer uses available well hydrostatic pressure to set it in place. This type of
packer is deployed on casing or tubing using regular completion techniques. Once
the packer has reached the intended setting depth, a pre-determined tubing or
annulus surface pressure is applied to increase the hydrostatic pressure at the
packer. As the hydrostatic pressure approaches the setting pressure of the packer,
the setting will begin. This process is performed in an un-perforated or isolated liner
without any well intervention or tubing plugging devices. Refer to the Packers
Dialog help topic for more information.
Synthetic Based Fluids
Synthetic fluids can now be easily input using the WELLCAT user interface. Refer
to the Synthetic Muds Tab help topic for more information.
5000.1.7
Page 336 of 423
May 2010
Draft
ISO Service Load Safety Factor
Safety factors are now calculated for ISO connections based on the input load
data. ISO connections can be imported directly into the String Sections. If the
connection is selected, it is applied to the stress calculations. ISO safety factors are
reported when the ISO safety factors are less than the corresponding pipe body
triaxial safety factor.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Three main definition modes are supported, including overall fluids, user-defined,
or default fluid property description. Thermal, solid contents, and rheological
properties specific to the fluids can be specified depending on the fluid definition
mode selected. Diesel thermal properties can be used instead of fluid thermal
properties if these are not available.
The analysis returns the polynomial equation and coefficients which are used by
the MultiString AFE analysis.
Tips for EDM WELLCAT Users
Well Explorer
Current users of other EDT applications will notice the Well Explorer is now part of
the WELLCAT user interface. The Well Explorer is used to browse, open, copy,
delete, and manage the main data items in the database hierarchy, including
Companies, Projects, Sites, Wells, Wellbores, Wells, Designs, Cases, Virtual
Folders, Contractors, Catalogs, and Templates. Please refer to Working with Well
Explorer for more information.
Creating and Saving a New Design
1. First of all, you must have a template saved to the database. Perform the
following steps to save a template to the database.
•
Use File > Template > Open From File. Navigate to the location of the
template file you want to import, select the file, and click Open. Example
templates are provided with the software.
•
Use File > Template > Save to save the template to the database as a User
Defined Template.
•
Use File > Close to close the template.
2. Create a design. You can use File > New > Instant Design or you can create
on step-by-step from company to design using File > New > Company, then
File > New > Project, etc.
5000.1.7
Page 337 of 423
May 2010
Draft
Now that WELLCAT is on EDM, you can take advantage of the integration between
WELLCAT, and the other Engineer's Desktop (EDT) Drilling Applications based on the
EDM platform. EDM is the platform for fully integrated well engineering and data
analysis. EDM provides one-time data entry, a system to promote best practices, and
an environment for managing and accessing operational knowledge and lessons
learned.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
3. Select the module (Drill, Prod, etc.) you want to use, input data, and to
calculate and analyze results as you did in the past with a WCD file. If you are
creating a TLP, refer to the Creating a TLP section in this help topic.
4. Now, save the Design. You can use File > Save > Save to Database to save
the design to the database, or use File > Save > Save to File to save to a
WCD file. Note that the design must be open in order to save it to a WCD file.
Importing a WCT Template, and Saving it to the EDM Database
1. Open the WCT template file using File > Template > Open From File.
3. Save the template as a System template using Template > Save As System
Template, or as a User-Defined template using Template > Save As.
4. The templates will be available for use after they are saved to the database.
Exporting and Saving Designs as WCD Files
You can export a design as a WCD file if the design is open. If the design is closed,
you can export as an xml file, but not as a WCD file. Use File > Export > WCD File
to export the design as a WCD file. You can also use File > Save > Save to File to
save as a WCD file. To export as an xml file, right-click on the design in the Well
Explorer, and select Export.
Working with WCD Files
You can open a WCD file using File > Open > Open From File or File > Import >
WCD File. Both of these options function in the same way. When you open the
WCD file, you can use the WELLCAT modules, and tools to perform your analysis
as you have done in the past without saving to the database. Upon completion of
your analysis, you can save as a WCD file (external to the database), or to the
database. To save to a WCD file, use File > Save > Save to File. To save to the
database, use File > Save > Save to Database.
5000.1.7
Page 338 of 423
May 2010
Draft
2. Select the template using the Import Template File dialog that displays.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Creating a TLP
To create a TLP design, perform the following steps.
1. Initially, create the design as a platform with the appropriate information for
water depth, wellhead depth, and air gap.
2. Use the Wellbore > General dialog and change the Location field to be TLP/
Hybrid.
3. Notice that the Wellbore > Offshore dialog has changed to allow input for a
TLP.
Previous File or Folder Location
WELLCAT 2003.21.1 File and Folder Locations
Client Folder and Files
With the exception of example WCD and template files,
all files previously located in the Client folder are now
located in Documents and Settings\Your User ID\Local
Settings\Application Data\Landmark\WELLCAT.
Server Folder and Files
This folder and files are now located in the
WELLCAT\Server folder in the folder where you installed
EDT. For default installations, this is
Landmark\EDT_xxx\WELLCAT\Server where xxx is the
version number of the EDT install.
Example Files
These files are by default stored in the
WELLCAT\Example Files folder in the folder where you
installed EDT. For default installations, this is
Landmark\EDT_xxx\WELLCAT\Example Files where xxx
is the version number of the EDT install.
Template Files
These files are by default stored in the
WELLCAT\Templates folder in the folder where you
installed EDT. For default installations, this is
Landmark\EDT_xxx\WELLCAT\Templates where xxx is
the version number of the EDT install.
Now that WELLCAT is on EDT, templates must be stored
in the database before they can be used to create new
designs. Refer to the section titled Creating and Saving
a New Design in these Release Notes, or to Using
WELLCAT Templates in the online help for more
information.
5000.1.7
Page 339 of 423
May 2010
Draft
WELLCAT File Structure
Now that WELLCAT is on EDM, the data file locations are different from the file
locations in previous versions. Please note the following changes
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Previous File or Folder Location
WELLCAT 2003.21.1 File and Folder Locations
Report.rpt
Default copies of these files that are not used are placed
in the WELLCAT\User Defaults folder in the folder where
you installed EDT. For default installations, this is
Landmark\EDT_xxx\WELLCAT\User Defaults where xxx
is the version number of the EDT install.
Library.lib
The files that are used are located in Documents and
Settings\Your User ID\Local Settings\Application
Data\Landmark\WELLCAT.
Unit Systems
WELLCAT now uses the EDT Unit System. As a result, stress default units have
been changed from ksi to psi.
5000.1.7
Page 340 of 423
May 2010
Draft
Changing Data File Locations
Now that WELLCAT is on EDM, the data file locations are different from the file
locations in previous versions. Use File > Data File Locations to point to the data
file locations you want to use. This option is only available when you first start
WELLCAT, before any files or designs have been opened.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Importing and Exporting Grades Flowcharts
The following shows a case where the Grade Name exists and Grade Properties
match.
Draft
5000.1.7
Page 341 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
The following shows a case where the Grade Name exists but the Grade
Properties do not match.
Draft
5000.1.7
Page 342 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
The following shows a case where the Grade Name does not exist.
Draft
5000.1.7
Page 343 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WELLCAT Fixed Issues
The WELLCAT issues fixed for 5000.1.0 through 5000.1.7 are described below. Also
described are the issues that were fixed in the 2003.21.1.0 limited release.
Release 5000.1.7
The following WELLCAT issues were fixed or have a workaround for the 5000.1.7
release.
Description
145721
Report says no bit data, while the Drilling operation had a bit defined.
775695
Incorrect calculation of Dogleg values in Casing and Load Summary if the
current string is inside more than one string.
802747
CASING card mapped incorrectly in configurations associated with liner
strings.
830573
DEX import survey > 90 degrees creates problems in PROD and TUBE
calculations.
832356
Change of precision between versions causes incorrect pressures in AFE
tubing external pressures.
832659
Misspelling in Tube Movement Summary header.
832662
Water Saturation Plot scaling not correct for inlet conditions point in SI
units.
832665
Drill input report incorrectly shows Yes for inner string when it is not used
in cementing operation.
832746
Volume cell highlighted in operation input details when spacer ahead in
volume placement method is fully pumped out for a fully cemented pipe in
new cement job table.
832760
Initial Conditions parameters are not properly initialized on opening
StressCheck Design (refresh issue).
833341
Tubing initial conditions temperature data is not shared properly between
StressCheck and WELLCAT.
833398
StressCheck file, when imported directly in WELLCAT, is not updating the
initial conditions temperature data for TUBE properly.
833679
Update Help description of Pressure Test Load in CASING and TUBE
modules.
833685
Synthetic-based mud shows correct unit but incorrect value.
834087
Incorrect handling of regional computer setting (Norwegian) causes bogus
message.
5000.1.7
Page 344 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Defect No.
Description
834162
MULTISTRING Initial Conditions loads do not approximate/match
CASING module Initial Conditions loads.
834626
Incorrect force sign convention in Packer Envelope and Loads in EDM
5000.
Release 5000.1.6
Defect No.
Description
149075
Missing formation temperature output displayed in GUI in Drilling
Operations
614758
The maximum allowable pressure input value in custom loads needs to be
greater than 30,000 psi
799727
Coiled Tubing Inventory - ID is no longer calculated after entering OD and
Wall Thickness
799816
Changing PROD Fluid Pressures plot thru output wizard in presence of
Heat Conduction Properties in paned view causes abnormal termination
799827
Coiled Tubing Inventory - Information in memory is no longer refreshed
after a new record is added
805268
Current Well Schematic DRILL module does not show the correct picture
for some drill operations
813666
Incorrect annulus pressure assumed by TUBE when plug is set below
packer depth but prior to EOT
817726
Tube Custom Loads - ESP Pumped, External Pressure Profile below
packer incorrect
818320
WELLCAT crashes when selecting a tubing string from Selection toolbar
820988
Safety Factor summary table displays wrong Bust Safety Factor when
available connection has lower safety factor
821595
Annular contents - a crash can occur if Casing and Tubing Configuration
data is not present
821602
Centralizers - a crash can occur if Casing and Tubing Configuration data
is not present
822060
Questionable MULTISTRING Progress failure analysis results
823101
WELLCAT 5000.1.5: performance issue VLE Hydrocarbon
823199
UPGRADE: Unit convertor to be available in all fields of WELLCAT.
5000.1.7
Page 345 of 423
May 2010
Draft
The following WELLCAT issues were fixed or have a workaround for the 5000.1.6
release.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
823845
Burst Safety Factor in MSF/ Safety Factor Summary results differ from
Multiple Loads > Burst Safety Factor
824967
Cannot enter Save then use trajectory in WELLCAT
825281
Differences in final temperature of the VIT tubing (VIT) from TUBE results
825282
Discrepancies of axial load plots/tabular with/with out bending
825283
Questionable zero pump pressure in an inner string subsea cementing job
operation
825286
Presence of plug ignored in a specific scenario
825288
Incorrect annulus fluid in a gas lift scenario
825290
Centralizer applied seems to not have an effect on axial load/buckling
results on a specific multi-section scenario
826025
The packer Latching Force differs in the TUBE Results tables
827823
AFE calculations failed due to exceeding maximum number of
compositional fluid allowed
829113
Performance problem saving WELLCAT release 2003 file into EDM 5000
database
829228
Questionable Heat of Hydration released trend when same slurry is used
both as lead and tail
829879
Need to change the reporting depths in certain load cases (Gas Kick) in
CASING module to improve the usability of a consolidated MSF table
829924
Incorrect Casing temperature Profile in Initial Conditions when using the
Fill button.
830032
WELLCAT PROD: VLE Hydrocarbon: phase envelope problem
830136
TUBE displacement calculation not working
830139
Inventories: Synthetic Muds: Legend Temperature issue
830331
WHM load history referencing to conductor drive pipe instead of
conductor driven for legacy files
830413
In SI units cannot reselect OD of API connections in string sections of
casing and tubing configuration
5000.1.7
Page 346 of 423
Draft
Defect No.
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.5
The following issues were fixed for the 5000.1.5 release of WELLCAT software.
Description
755697
Review Well Head Movement calculations methodology when a full thermal history
of drilling operations is included in Multistring Wellhead Movement calculations.
773956
Common Well Explorer: WELLPLAN Design/Cases created from WELLCAT
Designs do not display "String OD and string type name" for running cases in the
Common Well Explorer.
798148
Irregular axial load with depth reported for Running in Hole load.
807523
Pressure increment logic for production operations not working properly.
813152
Invalid argument caused by incorrect auto-generated wellpath stations.
813155
Zero external pressure after applying default custom load option.
813300
VLE puts secondary correlation label where production rates label should be in
Details.
813414
AFE custom loads dialog show wrong external fluid below packer.
813415
Frac screen out load does not take annulus pressure input.
814670
Import pipe editor displays zero on burst and collapse fields of standard pipe records
when it should display as grayed out.
814679
Lack of synchronization of pipe and annulus tabs within Custom load main dialog
options and fill pipe annulus associated tabs.
814805
WELLCAT General dialog box has incorrect well total depth for a file created in
COMPASS thereby not allowing a user to work with the Design in Prod or Drill
module.
814824
WELLCAT crashes while trying to view certain kinds of reports.
815052
5000.1.2.2 WSTUBE closes with many load cases.
815526
Diagnostics options Help button and F1 key displays the edit input file topic instead
of the displayed option.
816269
Missing time reference on reported HCT files.
816270
Depth precision discrepancies if old WCD files are modified in WELLCAT 5000 prior
to reset units system.
816272
Slackoff defined for continuous string appears to be ignored in Multistring Wellhead
Movement Analysis.
816387
WELLCAT crashes when applying switch Plot/ Spreadsheet button in Prod mode.
816524
PROD calculation process stopped due to adding unnecessary number of depths of
interest.
5000.1.7
Page 347 of 423
Draft
Defect No.
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
816663
Tubing Less_Custom Loads casing Prod link workflows fail to map densities,
pressure and temperatures.
816667
Invalid tubing leak load option allowed in tubing less scenario causes zero internal
pressure profile.
817217
Multistring locks up while executing calculations due to flaw in configuration logic.
817332
Duplicated Cement slurry fluids are auto-generated 2003.0.4 WCD files are
imported.
817624
Incorrect outer VIT pipe temperature profile reported.
817820
Incorrect data was displayed for Lead Slurry in Cementing and Landing dialog
819010
Incorrect synthetic fluid density calculations for mix fluids.
819174
Incorrect Axial load applied in a suspension mud system
Release 5000.1.4
The following WELLCAT issues were fixed or have a workaround for the 5000.1.4
release.
Defect No.
Description
787853
Selecting F1a second time brings up the wrong Help topic.
792669
Improve Gas Kick load case details
793037
For Gas Kick, Displacement to Gas, and any other load (Lost Return: With
Water/Mud Drop), the old values should be honored.
802964
Pipe weight in string section is removed on switching to default SI viewing
unit system.
803985
Packer resets on saving WCD file to database.
806922
Copy to EXCEL (Shell) for safety factor views w/ flags in spreadsheet
option ON copies flags in each column of EXCEL spreadsheet.
810088
WELLCAT crashes when entering synthetic mud data to Inventory.
810155
Gel injection control input error during calculation.
810156
Missing connection data when opening a design created in WELLCAT
2003_0_4 in the WELLCAT 5000 version.
810401
Incorrect conversion value applied to water density (synthetic).
810425
Verify K’ unit input change in the WELLCAT 5000 release.
810427
Inconsistency on Packer reported results (Packer Schematic and Packer
Summary) vs other reports.
5000.1.7
Page 348 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
810452
Pressing F1, without a design open fetches the wrong Help topic.
810454
Significant performance issues when opening a file across the WAN.
810708
Need to update the following help documents: Application of Temperature
Deration, Temperature Deration, Tubing to Packer Force, and AFE Gas
Cap Volume Annular reference.
810780
Can’t open StressCheck files directly in WELLCAT 5000.1.2.
811240
The right side of the dialog (Load History) does not update automatically
to SI units.
811321
Load (RIH) position in Load list dialog affects results in CASING module.
811608
Incorrect flag reported in displacement study calculations.
811713
Entering a VLE from scratch is causing a crash when the user specifies
heavy components.
Release 5000.1.3
No WELLCAT issues were fixed for the 5000.1.3 release.
Release 5000.1.2
The following WELLCAT issues were fixed or have a workaround for the 5000.1.2
Defect No.
Description
797983
Wall-thickness Geometry dialog box sheet, which would not populate the
material when a Wall-thickness is chosen.
797981
Importing catalog data does not enable the save button.
release.
Release 5000.1.1
The following WELLCAT issues were fixed or have a workaround for the 5000.1.1
release.
Defect No.
Description
172852
Inventory window divides into several headers when using the mouse to
scroll upwards.
5000.1.7
Page 349 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
615717
Steady-state solution differs appreciably from long term transient solution
for circulation.
618639
Performance issue for Production operation including VLE.
622138
Subsea wells are not correctly handled when the wellhead is above the
mudline.
622736
Wellhead movement pressure calculations are initiated at zero depth
reference for outer-most string.
626003
Displacement to Gas load - When the current casing is followed by a liner
and then by another hole section below that liner, the Influx Depth cannot
be set to a depth within the second hole section situated below the liner
base.
626007
Displacement to Gas load - Incorrect Pore Pressure default
626312
Displacement to Gas load - Incorrect Fracture at Shoe default
634474
When using the Tube module, the Movement Summary is incorrect for
Overpull load case.
702189
Adding a new line to the Formation Properties spreadsheet produces a
crash.
703462
Gas Kick load - When using scab liners, the maximum allowable Influx
Depth value is incorrect.
703685
Fluids Inventory - The presence of the PVT Table Properties data is
confusing because it is not used in WELLCAT.
704137
Casing Design Limit plot is not displayed in the report print preview when
pagination set to one item and sorted by loads.
714938
When the hanger depth of strings are below the mudline during drilling
calculations, a negative cross-section error occurs.
715047
Tubing Leak load case linked to Undisturbed maps to incorrect
temperature.
716193
When more than one report document (besides the packer diagram) is
added to the report, the packer diagram is not displayed in the report
unless it is on the first page.
719557
When using the Tube module, zero pressure values are incorrectly
reported in internal/external pressure column when duplicate surveys
exist.
719932
Incorrect Axial Load is displayed below packer depth in Packer Load
Summary table and Packer Schematic “Tubing To Packer View”.
720509
Report N/A, rather than zero, for packer forces in Overpull load cases in
the Multiple Packer Loads view.
5000.1.7
Page 350 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
721211
Implement hanger lift off and axial load redistribution analysis. Refer to
the Engineering Enhancements section of these Release Notes for more
information.
721268
Implement stress analysis for VIT configurations.
721383
WELLCAT abnormally terminates during calculations when there are
more than 20 tubing loads defined.
721384
When there are duplicate names in the Fluids drop-down list and the
duplicate names were deleted, an invalid argument was encountered
when displaying details for a properly defined shut-in load case.
721385
Incorrect internal pressures for some shut-in load cases.
721496
The Prod module should output the perforation depth for annular flow path
in addition to the tubing flow path.
721523
Incorrect Critical Burst rating values are reported in the Rating Summary
table
721549
Drill calculations exceed time warning and halt while displaying progress
bar.
721555
When a slackoff force is applied after the first stage of cement, but prior to
the second cement stage, the effect this force has on string buckling
during the second stage cementing is ignored.
721579
Incorrect fluid distribution in a shut-in annulus following hydrocarbon
production.
722092
Full Gas displacement load scenario selecting incorrect EMW and
reference depth values for pore pressure and fracture gradient.
722127
Multax AFE custom loads for liners, in certain configurations, has
incorrect final temperatures.
722128
For Casing Custom Loads, the Prod temperature results cannot be
shared using the Fill Temp option.
722132
When a void at the bottom of the tieback is simulated by using the
Uncemented Gap option in Cementing And Landing dialog of the Casing
module, there are incorrect results for axial loads.
722134
For Lost Returns Casing loads, the pore pressure input changes when
tabbing out of the Loss Zone field.
722138
Copy load functionality for Running in Hole load case does not copy the
average running speed.
722296
The Casing Module fails to while performing stress analysis calculations
for some TLP/hybrid type configurations.
722297
Incorrect input temperature mapping for AFE custom loads leads to
incorrect results for stress analysis.
5000.1.7
Page 351 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
722405
MultiString does not recognize available PROD results and requires
results to be recalculated.
722408
Calculation of Multistring results are not completed when the string
includes VIT pipe with many tubing string sections.
722484
Multistring module was using temperatures for the wrong casing from the
Prod results.
728795
Incorrect results when well is killed after production of HC/shut-in. Refer to
the section titled Modeling Kill Operations Following an HC/Shut-In
Scenario following this list of Fixed Problems.
728805
Incorrect buckling length reported when using the Tube module.
729269
Incorrect axial load distribution in when the expansion joint is set close to
the packer.
730802
The Mudline suspension landing data when applied from surface to
subsea wellhead is not handled correctly.
730802
The mudline suspension landing data when applied from surface to
subsea well head is not mapped correctly.
731176
WELLCAT locks up when trying to access AFE Custom Loads.
732248
Capstan effect is not calculated correctly when there are many survey
points.
733012
The In-House Connection Test Data envelope is not appearing on the
Design Limits Plot.
733854
Multistring cannot analyze continuous strings suspended at the mudline
and the surface.
736122
Coiled tubing input volume data is not retained after input.
736144
Multistring calculations failed while defining AFE custom loads.
736611
Pressure mapping is incorrect while applying Capstan effects.
737895
Gas kick pressure profile requires additional interpolation point.
738379
When document history is turned off using Windows configurations,
WELLCAT abnormally terminates when the File menu item is selected.
742779
Calculations with Seal Movement allowed, but with nogo present and
movement equal to zero, differs from calculations with no movement
allowed.
745794
Incorrect Axial Load result below packer.
747574
Differences observed in results when compared to past releases due to
modifications to wellhead movement calculations.
5000.1.7
Page 352 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
748657
Error occurs, and execution halts when running displacement study
calculations using the Tube module.
749038
Slow execution time using Steam module.
749926
Casing card error in coiled tubing operations.
755901
When using the Design Limit plot, multiple plot views are generated by
scrolling the mouse wheel.
756549
Status Bar is missing SAM, Datum Elevation, Unit System, and User
icons.
757776
WELLCAT is not able to check out more than 3 licenses simultaneously
using redundant license servers.
758140
When using the Tube module, inaccurate results are displayed for annular
pressure for packer loads on the Results Summary.
763527
Expansion Joint stress analysis as the same axial load distribution when
compared to packer only scenario.
766919
AFE Custom Load Report format and mapping should be done according
to the new AFE custom load interface format.
766931
Incorrect temperature versus time results while circulating the same
equivalent amount of time as drilling days specified with multiple tripping
operations.
767655
Incorrect calculation of general fluid properties.
768073
Riser can no longer gel if there is flow in the annulus. This fix may result in
different predicted temperatures when compared to previous software
release where riser gel was on by default.
769713
Inaccurate discontinuity (TOC) in axial load plot
769731
Axial results differ depending on how the string is split into sections.
770119
Incorrect temperature profile for custom loads linked to Drill operations.
770667
For specific workflows, inaccurate contact forces reported for Wellhead
Movement.
783356
External Pressure spikes back to zero at the top of cement.
788817
Incorrect default fracture gradient in a casing liner configuration for a
Displacement To Gas scenario.
792453
Difference in temperature in the vicinity of mudline.
5000.1.7
Page 353 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Reported MultiString Wellhead Axial Loads
Prior to this release, (1161) WELLCAT Wellhead Movement Axial Forces have
been calculated assuming Float failed scenario during Primary cement (landing
scenario). Also the application assumes the Datum elevation as the water surface
level. Also should the Cementing and Landing dialog is not checked while building
a wellhead movement analysis, the application would assume a default
displacement density for Primary cementing calculations (Landing scenario) in
wellhead movement calculations.
Well Inclinations Greater than 90 Degrees
WELLCAT can analyze well paths with inclinations less than 90°. Some EDT
drilling applications analyze well paths over 90°. If you are using WELLCAT to
analyze a well path greater than 90° created with another EDM application, a copy
of the well path will be reduced to 89.9° for analysis within WELLCAT. The actual
well path will not be altered. If you perform additional analysis with an EDT
application that does analyze well paths greater than 90°, the original well path will
be used.
Modeling Kill Operations Following an HC/Shut-In Scenario
When modeling a kill operation following an HC/shut-in scenario, WELLCAT
replaces the wellbore fluid (hydrocarbon column with GOR = 0 below the kill fluid)
with the injected fluid when calculations are initiated. This approach can lead to
inaccurate analysis if the injection time is short, or injection volume is small. To
minimize inaccuracies, it is recommended the injected volume be several times the
wellbore volume.
Hanger Depths
WELLCAT now honors and performs appropriate calculations of hanger depths for
offshore, subsea, and TLP wells, which were not honored by earlier versions. All
earlier versions extended mid-sea hangers either to the water level or to the
mudline. Because of this calculation change current results can be different from
results produced by earlier versions of WELLCAT depending on hanger locations
and input data. This difference is expected to be noticeable near the hanger top
and decrease with the depth.
5000.1.7
Page 354 of 423
May 2010
Draft
This release, has removed all these assumptions, now it honors the float status as
defined in the cementing and landing dialog in casing module. I also honor the
mean sea level depth and the displacement fluid as defined in the cementing and
landing dialog with not need for the user to check the dialog.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 2003.21.1.0 (Limited Release)
The following WELLCAT issues were fixed or have a workaround for the 2003.21.1.0
limited release.
Description
172852
Inventory window divides into several headers when using the mouse to
scroll upwards.
622138
Subsea wells are not correctly handled when the wellhead is above the
mudline.
634474
When using the Tube module, the Movement Summary is incorrect for
Overpull load case.
719557
When using the Tube module, zero pressure values are incorrectly
reported in internal/external pressure column when duplicate surveys
exist.
719932
Incorrect Axial Load is displayed below packer depth in Packer Load
Summary table and Packer Schematic “Tubing To Packer View”.
720509
Report N/A, rather than zero, for packer forces in Overpull load cases in
the Multiple Packer Loads view.
721211
Implement hanger lift off and axial load redistribution analysis. Refer to
the Engineering Enhancements section of these Release Notes for more
information.
721268
Implement stress analysis for VIT configurations.
722296
The Casing Module fails to while performing stress analysis calculations
for some TLP/hybrid type configurations.
722297
Incorrect input temperature mapping for AFE custom loads leads to
incorrect results for stress analysis.
721383
WELLCAT abnormally terminates during calculations when there are
more than 20 tubing loads defined.
721384
When there are duplicate names in the Fluids drop-down list and the
duplicate names were deleted, an invalid argument was encountered
when displaying details for a properly defined shut-in load case.
721385
Incorrect internal pressures for some shut-in load cases.
721496
The Prod module should output the perforation depth for annular flow path
in addition to the tubing flow path.
721549
Drill calculations exceed time warning and halt while displaying progress
bar.
722127
Multax AFE custom loads for liners, in certain configurations, has
incorrect final temperatures.
5000.1.7
Page 355 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
722128
For Casing Custom Loads, the Prod temperature results cannot be
shared using the Fill Temp option.
722132
When a void at the bottom of the tieback is simulated by using the
Uncemented Gap option in Cementing And Landing dialog of the Casing
module, there are incorrect results for axial loads.
722134
For Lost Returns Casing loads, the pore pressure input changes when
tabbing out of the Loss Zone field.
722405
MultiString does not recognize available PROD results and requires
results to be recalculated.
722408
Calculation of Multistring results are not completed when the string
includes VIT pipe with many tubing string sections.
722484
Multistring module was using temperatures for the wrong casing from the
Prod results.
728795
Incorrect results when well is killed after production of HC/shut-in. Refer to
the section titled Modeling Kill Operations Following an HC/Shut-In
Scenario following this list of Fixed Problems.
728805
Incorrect buckling length reported when using the Tube module.
729269
Incorrect axial load distribution in when the expansion joint is set close to
the packer.
730802
The mudline suspension landing data when applied from surface to
subsea well head is not mapped correctly.
732248
Capstan effect is not calculated correctly when there are many survey
points.
733854
Multistring cannot analyze continuous strings suspended at the mudline
and the surface.
736144
Multistring calculations failed while defining AFE custom loads.
736611
Pressure mapping is incorrect while applying Capstan effects.
738379
When document history is turned off using Windows configurations,
WELLCAT abnormally terminates when the File menu item is selected.
747574
Differences observed in results when compared to past releases due to
modifications to wellhead movement calculations.
749926
Casing card error in coiled tubing operations.
755901
When using the Design Limit plot, multiple plot views are generated by
scrolling the mouse wheel.
757776
WELLCAT is not able to check out more than 3 licenses simultaneously
using redundant license servers.
5000.1.7
Page 356 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
758140
When using the Tube module, inaccurate results are displayed for annular
pressure for packer loads on the Results Summary.
763527
Expansion Joint stress analysis as the same axial load distribution when
compared to packer only scenario.
768073
Riser can no longer gel if there is flow in the annulus. This fix may result in
different predicted temperatures when compared to previous software
release where riser gel was on by default.
769713
Inaccurate discontinuity (TOC) in axial load plot
770119
Incorrect temperature profile for custom loads linked to Drill operations.
770667
For specific workflows, inaccurate contact forces reported for Wellhead
Movement.
5000.1.7
Page 357 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WELLCAT Known Issues
The following WELLCAT known issues for releases 5000.1.0 through 5000.1.7 are
described below. Also described are known issues for the 2003.21.1.0 limited release.
Release 5000.1.7
The following are WELLCAT known issues for the 5000.1.7 release.
Description
834174
Unexpected behavior of TUBE displacement calculations.
834355
Modeling reverse circulation after a fracture operation delivers an error.
834578
Incorrect External Pressure Profile in dual completion custom load.
834580
Missing results in dual tubing scenario Multiple loads, Packer Loads table.
834822
Packer setting sequence causing incorrect external pressure in Annular
Press Test.
834835
Packer setting sequence causing incorrect external pressure for a
Pressure Test Load.
Release 5000.1.6
The following is a WELLCAT known issue for the 5000.1.6 release. .
Defect No.
Description
830573
DEX import of a survey > 90 deg creates problems
Release 5000.1.5
The following are WELLCAT known issues for the 5000.1.5 release.
Defect No.
Description
813666
Incorrect annulus pressure assumed by TUBE when plug is set below
packer depth
815866
Incorrect annular temperature in a PROD only OIL operation at a specific
OIL API.
5000.1.7
Page 358 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.4
There are no additional known WELLCAT issues for the 5000.1.4 release.
Release 5000.1.3
There are no additional known WELLCAT issues for the 5000.1.3 release.
Release 5000.1.2
Draft
There are no additional known WELLCAT issues for the 5000.1.2 release.
Release 5000.1.1
The following are WELLCAT known issues for the 5000.1.1 release.
Defect No.
Description
180610
Scab liner ignored for tubing stress analysis.
619895
Casing Load Summary fails to report data at Plug Depth from Pressure
Test case.
628970
Production and injection wellhead loads use the undisturbed temperature
profile rather than the corresponding PROD temperatures.
701665
Buckling restriction is not correctly applied when multiple string section
outside diameter sizes exist.
705217
An error occurs when calculating the displacement study in TUBE if the
Running in Hole load is included.
755697
Review Well Head Movement calculations methodology when a full
thermal history of drilling operations is included in Multistring Wellhead
Movement calculations.
756471
Insert and Delete keys do not work on the Well Explorer nodes.
756786
Incorrect float collar depth when operation is copied.
756870
The Apply button does not work in Custom loads Fill dialog for any option
(internal or external).
760285
Tubing cross section areas in packer schematic incorrect if cross-over
present.
760628
Undo does not work in Centralizer spreadsheet after deleting rows from
the spreadsheet or after changing a value in any field.
5000.1.7
Page 359 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
761603
By default, no unit system is indicated as selected by default after new
install.
762475
Display may flicker when tabbing between fields on the Casing and
Tubing Configuration spreadsheet.
762489
The ISO envelope is un-selected when switching between string sections.
763475
The Max DLS for MD-TVD type input in legacy files is set to NULL or
blank when importing into WELLCAT EDM. It is not possible to edit or
delete these rows after import.
764618
Change history is not updated to reflect changes made in WELLCAT.
767287
Refresh issue when exporting ISO connection to ISO library. User may
have to re-open the ISO library to see the exported connection.
767344
Drill and Prod operations results are lost when user selects Casing/Tube
connections in String Section table.
767345
In SI units, the Nozzle Size on the Drilling Operations > Drill String tab is
shown as 1/32 in.
767789
File > Import > Transfer File is disabled when re-opening WELLCAT after
closing when the Well Explorer is closed.
768178
Typing in prior operation drop-down in Drill Operations can cause
WELLCAT software to abnormally terminate.
770070
When using the Casing or Tube modules, and a new casing or tubing load
is added, it should display in the Design Limits Plot after results are
calculated.
773956
WELLPLAN Cases created from WELLCAT casing designs do not display
the string name in the Well Explorer Associated Data Viewer for running
scenarios.
775646
VIT tubing details (OD, ID, Weight, Grade, and all other properties) should
be added to the EDM database.
788070
When changing input values in AFE analysis, user needs to recalculate to
update plots.
793403
Slight difference in calculated Packer to Casing Force results (during
initial conditions) caused by rounding error of differential pressure in some
specific datasets.
5000.1.7
Page 360 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 2003.21.1.0 (Limited Release)
The following are WELLCAT known issues for the 2003.21.1.0 limited release.
Description
761318
Help > About WELLCAT does not display licenses in use.
761603
By default, no unit system is indicated as selected by default after new
install.
761910
Import edm.xml file does not display a progress bar.
760681
Although the spreadsheet are now displayed in reports, the fonts and grid
need to be adjusted.
756870
The Apply button does not work in Custom loads Fill dialog for any option
(internal or external).
764171
A scrollbar pops is unnecessarily displayed in the middle of the screen
when switching designs using tubing assembly.
764618
Change history is not updated to reflect changes made in WELLCAT.
767789
File > Import > Transfer File is disabled when re-opening WELLCAT after
closing when the Well Explorer is closed.
756549
The Status Bar does not display SAM, Datum Elevation, Unit System, and
User icons.
769845
WELLCAT should not be able to edit locked designs.
770339
Copied design on same wellbore creates a second partially defined tubing
row.
763475
The Max DLS for MD-TVD type input in legacy files is set to NULL or
blank when importing into WELLCAT EDM. It is not possible to edit or
delete these rows after import.
768770
WELLCAT abnormally terminates when opening designs copied from a
dated planned design.
762871
Undo (Ctrl-Z) fails to remove a record pasted into the last row in the Pore
Pressure spreadsheet.
756471
Insert and Delete keys do not work on the Well Explorer nodes.
765324
When the well total depth in WELLCAT is deeper than the wellpath depth
specified in COMPASS, WELLCAT abnormally terminates when
calculating results.
769168
WCD files with file names containing more than 56 characters cannot be
saved to the EDM database after importing. Workaround: Before
importing the WCD file, rename it using a name containing less than 56
characters.
5000.1.7
Page 361 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
756511
The VLE Phase Diagram displays a message indicating the calculation
failed when the compositions are not normalized.
761745
Tables do not preserve their size when the data is changed.
767277
When using Citrix, ISO libraries cannot be imported even if the extension
is changed manually to the correct (*.lib) extension. Workaround: Place
library files that you want to import in a shared local folder. Contact
Landmark Customer Support for more information if necessary.
768610
Drill String Grade Properties fail to be created in EDM when exporting
HWDP or Drill Pipe items to an EDM catalog.
768178
Typing in prior operation drop-down in Drill Operations can cause
WELLCAT to abnormally terminate.
771190
When exporting Inventories to Catalogs, an incorrect message is
displayed that indicates data was exported. However, duplicates are
skipped.
5000.1.7
Page 362 of 423
May 2010
Draft
Defect
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Well Cost™ Software
Enhancements
Fixed Issues
Known Issues
The 5000.1.7 release includes all 5000.1.3 supported platforms, plus enhancements,
fixes, and known issues from the 5000.1.0 and subsequent EDT releases. Bug fixes were
made to the Well Cost software for the 5000.1.7 release.
The Well Cost enhancements and new functionality for releases 5000.1.0 through
5000.1.7 are described below.
Release 5000.1.7
There are no new enhancements to the 5000.1.7 Well Cost software.
Release 5000.1.6
Well Cost software version 5000.1.6 is a major update that:
•
improves configurability and further streamlines existing workflows,
•
builds on the strength of the program's integration with OpenWells and
COMPASS software, and
•
greatly enhances the analytical components with advanced Probabilistic
functionality.
This release fixes critical issues, listed in the Well Cost software section of the
Engineer’s Desktop Software Version 5000.1.6.0 Release Notes, and contains the
following new functionality:
5000.1.7
Page 363 of 423
May 2010
Draft
Well Cost Enhancements and New Functionality
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Production and Dry Hole Time and Cost
The production and dry hole costs are now included in the time and cost analysis
with the addition of Completions and Abandonment Events. The new Event types
can now be added to the active Design in the General Info pane.
General Info pane with new
Completion and Abandon event
types
Draft
5000.1.7
Page 364 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Active Well Status Monitoring
This new feature provides the ability to monitor an active well using the Offset Well
Selector in conjunction with the Planned vs Actual (Time vs Depth) plot's Hide Line
feature.
Draft
In this example, the offset well’s P50 line is shown with the active well, “GZ 1/16”.
5000.1.7
Page 365 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Partially Complete Well (Look Ahead)
A new section in the Deterministic pane allows you to configure the Design as
partially complete either manually, or automatically by synchronizing time with
OpenWells daily reporting. This feature is integral with Active Well Status
Monitoring and is used to evaluate future time and cost options after phases are
complete.
Partially Complete Well option checked
with the well completed up through drilling
the surface hole.
Partial well status is updated
from the OpenWells Operations
reporting system.
Draft
5000.1.7
Page 366 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Configurability Improvements
This release includes an enhanced Probabilistic analysis workflow that is made
possible through the new Probabilistic Options dialog. This multi-tabbed dialog
allows you to run simulations with a simpler configuration at the Phase level, or a
more detailed analysis at the Activity level.
Probabilistic Options dialog - default
Monte Carlo tab.
Draft
One of the first things you should do to familiarize yourself with this release is to
learn about the options available in this dialog.
The dialog also provides options that configure the Well Cost application to run
Probabilistic simulations, which includes the flexibility to model several types of
input variations such as:
•
Phase level analysis only - This option is good for simple analysis on the phase
level and can take input from offset wells without too much user intervention.
•
Activity level analysis - This option allows you to perform a more detailed
analysis for each operation. Activity analysis allows complex operations to be
defined like risk events (probable), scheduled activities and multiple threads
(one of a risk event happens and alternate if it goes well).
•
Correlations available to insert variable for:
— Time: This option influences the correlation effect on times (phase or
activities) with the same well construction. Normally a value of 60% will
model the P10/P90 spread realistically.
5000.1.7
Page 367 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
— Multiple Wells: This multiple well correlation operates between wells on top
of the single well time correlation. Normally a lower value like 30% is
adequate because multi-well correlation is at a lower value than correlation
in the same (single) well.
•
— Cost - Costs may be correlated if there is an association between the costs
like rising market rates, inflation or exchange rate dependency (local
prices).
Risks: Global risk expressed as:
Probabilistic Options dialog - Variation Input tab. The
current setup is for Phases, which provides a quick
estimate for projects with less detail.
For more detail, the Activities level
would be chosen.
Correlations applied
independently for Time,
Risks, and Costs
In addition to the new options found on the Probabilistic Options dialog, Well Cost
users will notice some familiar options available on the dialog that exist in the
previous release.
Landmark includes a default configuration with parameters and settings
reasonable for most simple well costing exercises.
5000.1.7
Page 368 of 423
May 2010
Draft
— probability per well, like Waiting on Weather or Rig Repair in Phase
variations, or
— per day probability, for events like tight hole, pack-off fishing, and sidetrack,
which you might experience with formation-related NPT.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Streamlined Interface
Several changes related to Well Cost workflows were made to the interface for the
purpose of improving the overall user experience.
•
New Panel Views and Spreadsheet - this version of the Well Cost application
integrates phase/activity and cost information in panels that display while
working in a new tree control hierarchy.
Tree control hierarchy for Phases and
Activities.
Each tree node has a coresponding
panel for data entry.
5000.1.7
Draft
The tree allows input of probable risk
events by percent probability to two
levels, including remedial activities
Page 369 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
— Most input occurs in the Time Configuration and Cost Configuration tree
panels. Some exceptions exist, such as configuration of partially complete
wells in the Deterministic pane, or modification of offset well information in
the Probabilistic pane.
Ability to choose offset wells from EDM
database or add custom user wells
Editable fields for
offset well data
Draft
5000.1.7
Page 370 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
— Added Tieback and Tubing production string section types to the Casing
pane.
.
Production Tubing
type added to Casing
scheme
Draft
•
Well Cost Wizard - the Well Cost Wizard was redesigned to support a more
intuitive workflow-driven experience that incorporates tree controls and simple
input panels, which removes the former method of data entry in complex
spreadsheets.
Wizard changes include:
— Time input is now completely driven through the new Time Configuration
panel. Previous versions of Well Cost software allowed input in the
Deterministic and Probabilistic pane spreadsheets, which are now available
primarily for review and analysis.
— Cost input is now completely driven through the new Cost Configuration
panel. Previous versions of Well Cost software allowed input in the Cost
pane spreadsheet, which is now available primarily for review and analysis.
Variations on Time, Cost, and Casing Depths
Well Cost software can be configured to use Phases or Activities to compute
probabilistic outcome. This release adds options to use variations on Time
(activities with risks), Cost, and Casing Depths.
5000.1.7
Page 371 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
The screen below shows the Time Configuration tree’s Phase panel. Notice the
new Casing Depth Variation option.
Draft
Variation on depth used.
Note the Query wizard option
available to use depths from
offset well data
5000.1.7
Page 372 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
The screen below shows the Time Configuration tree’s Activity panel. Notice the
variation on time is used with a specified distribution. In this example, a variation
on Flat Time is available.
Draft
Time based activities, both
planned and risk types, are
now represented in a tree.
5000.1.7
Variation on time used.
Note the Query wizard option
available to use times from
offset well data
Page 373 of 423
Ability to add probability to
risk.
In this case, there is a 90%
probability that this risk
activity will occur
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Distribution on drilling progress rate is also available, when Trip Rate and/or ROP
is greater than zero.
Variation on
time used.
Likewise, costs are presented in the Cost Configuration tree’s Cost panel. Notice
the variation on cost is used with a specified distribution. Multiple distribution types
are available, such as Uniform, Triangular, Weibull, Normal, Lognormal, PERT,
and Discrete.
Menu and Toolbar Changes
Some changes were made to the Well Cost menu and toolbar. The changes reflect
the redesign of the application to incorporate more powerful probabilistic analysis
options, and the improvement towards a more workflow-driven interface.
•
Removed the Edit menu. The cut, copy, and paste functions that were found in
the Edit menu are still available in the Composer menu.
•
Renamed the Planning and AFE menu to Input, and added the following new
commands:
— Probabilistic Options: The main options for the Monte Carlo simulation are
controlled through the Probabilistic Options dialog.
— Time Configuration: The Time Configuration pane contains a tree that
represents the activities and risks sorted by Rig Events. The pane is split
vertically, with the tree on the left and a panel on the right. The content
5000.1.7
Page 374 of 423
May 2010
Draft
This
variation
applies to
drilling
activities
with a
positive
value for
trip rate
and/or
ROP.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
viewed in the panel area depends on the selected item in the tree. For
example, if you select an activity in the tree, then the panel displays all
activity related data Well Cost software uses to perform calculations.
— Cost Configuration - The Cost Configuration pane contains a tree that
represents the costs sorted by cost categories. The default configuration
contains Intangible and Tangible categories, which you can modify via the
EDM Administrator Utility's Picklist Editor. The pane is split vertically, with
the tree on the left and a panel on the right. The content viewed in the panel
area depends on the selected item in the tree. For example, if you select a
cost item in the tree, then the panel displays all data Well Cost software
uses related to the selected item.
Renamed the Time and Cost Configuration command in the Input menu to
Config Spreadsheets.
•
Added a new Well Cost toolbar button (
simulation.
New menus: Input and Actions
) that runs the Monte Carlo
New button: Run Monte Carlo
Query Tool
This release adds a Query Wizard used to analyze offset well data, which can
come from other databases, or tabular files such as a Microsoft® Excel
spreadsheet. The Query Wizard allows you to perform statistical analysis of costs,
casing depths, activity times, and NPT frequencies for the purpose of using the
distribution parameters, such as Minimum/Likely/Maximum, as the basis for
variations on time or cost.
5000.1.7
Page 375 of 423
May 2010
Draft
•
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Some users will recognize the general layout of the Well Cost Query Wizard, which
is similar to the layout found in COMPASS software. The main difference is the last
screen, shown above, which includes a roll-up of the data returned by the query. In
this screen you can filter the data and apply various distributions to perform a more
in-depth analysis before accepting the values for the variation.
Open Query System
Well Cost software also extends keywords that can be used to request Offset well
Cost and Time data.
Cost Item Multiplier
Two new features are now available that allow you to compute cost items with
either a:
5000.1.7
Page 376 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
Global multiplier: to apply a rate for currency exchange in the Probabilistic
Options dialog's, or
•
Cost specific multiplier: to apply a formula to a single cost item in the Cost
Configuration pane's Cost Item panel, or the Cost Sheet.
Global multipliers in the Probabilistic
Options dialog’s Cost Calculation tab.
Draft
Global multiplier or custom formula
specified in the Cost panel
Global multiplier or custom formula
specified in the Cost sheet
5000.1.7
Page 377 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Monte Carlo Results
The full results of the Monte Carlo simulation output is too large for all possible
graphs or reports to contain, but can be reported to a text file. In order to generate
Monte Carlo Results, the Monte Carlo simulation must be run at least once in a
Design. The text file output can then be pasted/loaded into Excel as tab separated
text.
In order to use the Microsoft Excel
example spreadsheet that Landmark
ships with the product, open the
"WellCostOutput.xls" file located in the
Well Cost installation directory.
Enable macros if prompted, and then
select Load WellCost File button to
open the text file you saved.
5000.1.7
Page 378 of 423
May 2010
Draft
Accessed by the Well Cost Wizard, or
menu command. This command
saves the Monte Carlo results to a
text file.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Notice that with the data loaded, all the tabs are now populated. In this example,
the Phase Cost data and the corresponding charts display.
Draft
Plots and Charts
With this release, additional plots and charts were added to the existing ones.
Well Cost Plots
Wellpath
XY Graphs
Wellpath Section
Time vs Depth
Wellpath Plan
Time vs Cost
Cost vs Depth
Planned vs Actual (Time vs Depth)
Time vs P. Value (New!)
Cost vs P. Value (New!)
5000.1.7
Page 379 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
5000.1.7
Page 380 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Well Cost Charts and Histograms
Pie Charts
Histograms
Deterministic Phase Time Pie Chart
Well Time Histogram (New!)
Probabilistic Phase Time Pie Chart
Well Cost Histogram (New!)
Probabilistic Intangible Costs Pie Chart
Single Phase Histogram
Probabilistic Tangible Costs Pie Chart
Offset Well Times
Phase Time Histogram (New!)
Draft
Phase Cost Histogram (New!)
Split Cost Histogram (New!)
Risk Time Histogram (New!)
Risk Cost Histogram (New!)
5000.1.7
Page 381 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Online Help
An update to the Help includes a significant refactoring of the previous help system,
including the following new topics:
•
New approach to a Well Cost Workflow
— How to configure Well Cost software, found in the new Workflow
Configuration topic
— Replacement of the previous workflows with a new Example Workflow
•
List of all Well Cost specific tables found in the EDM database
•
List of formulas and constants available to alter the Cost Sheet and Probabilistic
cost calculations
Release 5000.1.5
•
Includes a new Report Manager version, which will reduce memory consumption,
increase report generation speed, and contains various other improvements.
5000.1.7
Page 382 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.4
There were no enhancements for Well Cost for the 5000.1.4 release.
Release 5000.1.3
•
New platforms are supported.
•
Mobile Checkout licensing feature libraries were added.
Draft
Release 5000.1.2
There were no enhancements for Well Cost for the 5000.1.2 release.
Release 5000.1.1
WELLCAT was added to the EDT suite of applications for the first time in the 5000.1.1
release. Also, some Common Well Explorer enhancements were made. (See EDT™
Software for details). This update release improves the import/export and sharing of
Grades, Pipes/Connections between StressCheck and WELLCAT, improves the
integration between StressCheck and WELLCAT, and repairs critical defects affecting
key StressCheck and WELLCAT application functions. There were no additional
enhancements for the Well Cost software.
Release 5000.1.0
The 5000.1.0 release of Engineer’s Desktop supports the Microsoft Vista operating
system, has new LAM (FLEXnet Publisher) licensing and contains some critical bug fixes.
Well Cost was added to the EDT software suite for the first time in this release. Well Cost
enhancements include the following:
Integration Enhancements
• Well Cost is now included with the Engineer’s Desktop suite of Drilling
applications, starting with this release.
5000.1.7
Page 383 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
Well Cost can now construct a sequential Operations Program, and transfer
Well Planning information to OpenWells.
On the Deterministic pane, click
on the Transfer To Well
Planning button to transfer
planning data to OpenWells.
Draft
Figure 1: Transfer to Well Planning
Probabilistic Workflow Improvements
• Offset wells can now be reordered chronologically in the Probabilistic pane,
with changes reflected in the Offset Well Times plot.
5000.1.7
Page 384 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
.
Select a row to move, then drag and drop
to the desired location.
Notice the Well is now
newly ordered in the
Plot and Legend.
Figure 2: Reorder Offset Wells
5000.1.7
Page 385 of 423
May 2010
Draft
Reordering the well
will also reorder the
Legend
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
Well Explorer Filtering applied to data tree in the Offset Wellbore Data Selector
dialog.
If a Filter is applied to
the Well Explorer, it is
also seen in the Offset
Wellbore Data
Selector.
Draft
Figure 3: Well Explorer Filtering Applied to Offset Wellbore Selector Dialog
•
Added picklists to the Probabilistic pane that allow you to apply three different P
values, and display as many as three probabilistic time lines (without doing a freeze
line) on the Time vs. Depth plot.
From these picklists, select either the arithmetic Mean, or a host of probability
estimates from P5 to P95 (increasing in 5 percentage point increments). The three
P values are applied to the Monte Carlo calculation. For example, if you select a
P90 probability estimate then there is a 90 percent chance that actual results are
greater than the P90 estimate. Therefore, P50 would be the median and P10 would
indicate a 10 percent likelihood that the actual results are greater than the P10
estimate.
5000.1.7
Page 386 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
Three P values on Probabilistic
spreadsheet.
Each P value is represented with
a line on the Time vs. Depth plot
Figure 4: Additional P Values on Probabilistic Spreadsheet and in Plot Results
The calculated results using the three P values display in the “Monte Carlo Value”
columns in the lower Probabilistic spreadsheet. For example, P2 calculated results
are seen in the “Monte Carlo Value 2” column fields. Also, the three P values are
represented with an individual line for each value on the Time vs. Depth plot.
Freeze line functionality is still available, but this feature allows you to quickly see
the result differences when three distinct P values are applied to the data.
Note
Only the first P value is used to calculate results in the Time vs. Cost
plot, and is differentiated in the spreadsheet with a darker
background color than the other Monte Carlo column fields.
5000.1.7
Page 387 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Plots
• For the Planned vs. Actual (Time vs. Depth) plot, the Offset wells are now
representative of the actual depths, not cut off at the same depth for all.
Activate the “Show Offset
Depths” checkbox to include
offset depths in the plot.
Draft
Figure 5: Show Offset Well Depths on Planned vs. Actual Plot
5000.1.7
Page 388 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
Added Offset Well Times plot, which includes plot controls that allow you to
display unplanned time and individual phase time for histograms directly from
the plot.
“Phase” picklist
“Show Only Unplanned
Time” checkbox
Draft
Figure 6: Individual Phases, Unplanned Time in Offset Wells Total Time Plot
Toolbar Buttons
The following new buttons were added to the Well Cost toolbar.
•
Auto Calculate - added the Auto Calculate toolbar button (
), which acts as
an on/off toggle to either allow data updates display dynamically in plots when
toggled on, or to improve performance when toggled off.
•
Calculate - added the Calculate toolbar button (
of changes in memory to the Design.
5000.1.7
Page 389 of 423
) to allow a manual save
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
SI Units
Implemented support for SI units.
Regional Settings
Implemented support for regional settings to support Internationalization functions
based on the Windows Regional Settings locale. When the Windows Regional
Settings is set to a non-English language, translations stored by Well Cost allow
the application to display in the specified language. Well Cost includes
internationalized text translations in the following languages:
English
Spanish
Portuguese
Chinese
Russian
Draft
—
—
—
—
—
Additional languages can be added as required.
Spreadsheet Improvements
The following spreadsheet enhancements were made in this release.
•
Deterministic time is now differentiated for clarity in the Deterministic
spreadsheet.
Deterministic Time differentiated from Probabilistic
Time in Deterministic spreadsheet.
Figure 7: Deterministic Time in Deterministic Spreadsheet
5000.1.7
Page 390 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
Bit types are now linked to EDM and displayed as a picklist in the Formation
spreadsheet.
Bit Type picklist in the Formation spreadsheet.
Draft
Figure 8: Bit Type Picklist in Formation Spreadsheet
EDT 5000.1 Software Common Well Explorer Enhancements
Click here to view a description of the EDT 5000.1.0 Well Explorer enhancements.
5000.1.7
Page 391 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Well Cost Fixed Issues
The Well Cost issues fixed for 5000.1.0 through 5000.1.7 are described below.
Release 5000.1.7
The following Well Cost issue has been fixed for the 5000.1.7 release.
Description
832667
Rounding and precision problems with cost and time entries in Cost and
Cost Tree dialogs.
832669
In the Query wizard, if some input values are zero, then the model comes
up with probable distribution. But, the wizard does not have this in the
menu.
832822
Under specific conditions, attempting to launch multiple copies of Well
Cost can cause the application to terminate.
832984
Unit Lengths in Time Calculation Probabilistic Options do not fully support
unit conversion.
833052
Selection of a number of XY Graph options in Wall Plot Composer leads
to termination of Well Cost.
833053
Three of the XY Graphs options do not add/display a plot in Wall Plot
Composer.
Release 5000.1.6
The following Well Cost issue has been fixed for the 5000.1.6 release.
Defect No.
Description
831035
User Configuration files and Monte Carlo Results maintained in common
directory location on Citrix environment.
832632
Activity data lost on data import due to incorrect Well Cost table meta
data.
Release 5000.1.5
No Well Cost issues have been fixed for the 5000.1.5 release.
5000.1.7
Page 392 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.4
No Well Cost issues have been fixed for the 5000.1.4 release.
Release 5000.1.3
No Well Cost issues have been fixed for the 5000.1.3 release.
Release 5000.1.2
Draft
No Well Cost issues have been fixed for the 5000.1.2 release.
Release 5000.1.1
No Well Cost issues have been fixed for the 5000.1.1 release.
Release 5000.1.0
The following Well Cost issues have been fixed for the 5000.1.0 release.
Defect No.
Description
733966
Add a picklist for Bit Type in formation spreadsheet.
739003
Add a column that displays the row number in Deterministic tabs.
740226
All spreadsheets in Well Cost should have numbers in first column like
other applications.
741839
Wall Plot tab does not save with a Design.
742610
Duplicate depths populated in formation on import.
743339
Display Deterministic/P10/P90 values on the TVD charts as standard,
rather than having to run the Monte Carlo 3 times & freeze lines.
744649
Reload for Casing updates not consistent with other EDT applications.
User must close and reopen Design to see Casing data copied from
another application.
744696
Add picklists for entering cost codes and sub cost codes in cost
spreadsheet.
745046
EDM or User selected wells in offset selector are not preserved.
746824
Need the ability to sort or arrange offset Wells.
747705
Tabs do not resize for long names.
5000.1.7
Page 393 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
747993
Performance issue with opening, copying, saving and creating a Design.
748274
Need a title for well schematic.
750319
Metric entry displayed as feet in Mixed API view.
751877
Flickering issue in Citrix environment for certain Well Cost pages.
752577
Phases Load save warning should be handled from within the dialog.
753143
Time for Deterministic should mention Deterministic for clarity in
Deterministic spreadsheet.
754198
Adding “no” User wells removes EDM wells.
756969
Cost spreadsheet has issue with regional settings where comma and
decimal are flipped.
767554
Deterministic filter does not work.
767560
Plots should update live with data entry, not after save.
767562
Need way to deselect offset Wells in the Probabilistic cost section.
767567
Transfer AFE to OpenWells creates two Events. Should populate the
Event Est. AFE Date and Est. Cost.
767569
Create AFE does not populate cumulative costs
(DM_AFE.cumulative_costs).
767576
Implement an auto calculate button similar to Data Analyzer and
WELLPLAN.
767577
Associated data well path stations are invalid.
767791
Freeze line does not work on the plots. Need to show P10, P50, and P90
lines on the plot.
767793
Planned vs. Actual plot for offset Wells needs to represent the actual
depths, and not cut off at the same depth for all.
767796
Add a Well Cost start token to the EDM Administration Utility.
767844
Regional and Language Options now recognize comma as a decimal
separator for Russian regional settings in Well Cost.
768201
Auto Phase loading not working.
768233
The name of the offset Well should use the Well names, not the Wellbore
names.
768321
Unable to delete User created offset Wells.
768324
Well Cost can now construct a sequential Operations Program, similar to
the same operation in Landmark’s DrillModel application. The Operations
Program that Well Cost creates feeds directly into the Operations
Program in the OpenWells Well Planning form.
5000.1.7
Page 394 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Description
770307
Now able to save plot settings for Offset Well Times, and Single Phase
Histogram.
770921
Transfer AFE to Event's Choose Event Dialog appears only once, and
Cancel button no longer crashes Well Cost.
771337
Wall Plots reflect unit conversions when Units are changed.
771416
Tubing/Casing Size are now disabled if open hole is selected.
771565
Users can now enter values in the Monte Carlo iteration field completely
before attempting to validate the data entry.
772348
Well Cost now supports Norwegian locale in the Well Path Editor.
772349
Fixed the problem of casing section picklists containing a “.” instead of “,”
in Non - English locale in over to allow selection of these types of values.
772363
Corrected cost discrepancies in Deterministic Intangible Pie Chart.
773457
Line colors can now be changed in plots.
776863
Well and Wellbore names now display correctly in the Offset Well dialog.
777192
Unit system in reports now match the active unit system.
777193
Deterministic cost table is no longer truncated in the report.
778038
Well Cost Detailed Report now includes the TVD Top field populated from
data in the Formations tab.
5000.1.7
Page 395 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Well Cost Known Issues
The following Well Cost known issues for releases 5000.1.0 through 5000.1.7 are
described below.
Release 5000.1.7
There are no additional Well Cost known issues for the 5000.1.7 release.
Release 5000.1.6
Draft
The following is a Well Cost known issue for the 5000.1.6 release.
Defect No.
Description
831592
Text output from Well Cost analysis for phases show random depths for
graphs when depth variation is turned on.
832066
When accessing Well Cost help by using the shortcut Help > Release
Notes, there is an error opening the help document if your system is
running Acrobat 8.
Release 5000.1.5
There are no additional Well Cost known issues for the 5000.1.5 release.
Release 5000.1.4
There are no additional Well Cost known issues for the 5000.1.4 release.
Release 5000.1.3
There are no additional Well Cost known issues for the 5000.1.3 release.
Release 5000.1.2
There are no additional Well Cost known issues for the 5000.1.2 release.
5000.1.7
Page 396 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.1
There are no additional Well Cost known issues for the 5000.1.1 release.
Draft
5000.1.7
Page 397 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.0
The following are Well Cost known issues for the 5000.1.0 release.
Description
770173
Need to improve the performance to load the Offset Well Data Selector.
770993
Well Cost should handle <Invalid> Grade Names and not throw
exceptions while opening a Design.
771207
F7 click on Time and Cost Configuration dialog crashes the Well Cost
application.
774491
Custom Rows added after disabling everything in Costs tab is not shown
at all.
776851
Plot legends do not resize with plot window.
780156
Negligible Total Estimate value difference between Cost Spreadsheet,
Well Cost Detailed Report, and Well Cost AFE Report ($0.20 difference
with $4.18 million estimate)
5000.1.7
Page 398 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WELLPLAN™ Software
Enhancements
Fixed Issues
Known Issues
The 5000.1.7 release includes all 5000.1.3 supported platforms, plus enhancements,
fixes, and known issues from the 5000.1.0 and subsequent EDT releases. Bug fixes were
made to the WELLPLAN software for the 5000.1.7 release.
The WELLPLAN enhancements and new functionality for releases 5000.1.0 through
5000.1.7 are described below.
Release 5000.1.7
There are no new enhancements to the 5000.1.7 WELLPLAN software.
Release 5000.1.6
There are no new enhancements to the 5000.1.6 WELLPLAN software.
Release 5000.1.5
•
•
•
More flexibility in calculating friction factors is now possible using the new Manual
Friction Calibration/Hook Load Chart. Using this chart, you can:
— Calibrate friction factors for multiple cased and open hole sections
— Calculate a weighted average of calibrated friction factors
— Create new sections corresponding to user defined intervals with individual
calibrated friction factors
— Automatically update the Hole Section Editor using the calibrated friction
factors. A weighted average of the calibrated friction factors can be applied to
existing hole sections, or new sections using calibrated friction factors can be
added.
Includes a new Report Manager version, which will reduce memory consumption,
increase report generation speed, and contains various other improvements.
Friction Factor upper limit has been increased to 5.
5000.1.7
Page 399 of 423
May 2010
Draft
WELLPLAN Enhancements and New Functionality
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
The following is a screenshot of the new Manual Friction Calibration/Hook Load Chart.
The Calculated Tripping In curve (red) is the calculated load line using the friction
factors specified on the Hole Section Editor. The Calculated Pinning Line (green) is the
load line using the calibrated friction factors displayed in the Manually Adjusted
Friction Factors section of the view. The calibrated friction factors can be manually
updated at any time. When updating the Hole Section Editor, the weighted average of
calibrated friction factors can be applied to existing hole sections. Alternatively, new
sections with calibrated friction factors can be added to the Hole Section Editor.
Draft
Release 5000.1.4
There were no WELLPLAN enhancements for the 5000.1.4 release.
5000.1.7
Page 400 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.3
•
New platforms are supported.
•
Mobile Checkout licensing feature libraries were added.
Release 5000.1.2
There were no WELLPLAN enhancements for the 5000.1.2 release.
WELLCAT was added to the EDT suite of applications for the first time in the 5000.1.1
release. Also, some Common Well Explorer enhancements were made. (See EDT™
Software for details). This update release improves the import/export and sharing of
Grades, Pipes/Connections between StressCheck and WELLCAT, improves the
integration between StressCheck and WELLCAT, and repairs critical defects affecting
key StressCheck and WELLCAT application functions. There were no additional
enhancements for the WELLPLAN software.
Release 5000.1.0
The 5000.1.0 release of Engineer’s Desktop supports the Microsoft Vista operating
system, has new LAM (FLEXnet Publisher) licensing and contains some critical bug fixes.
Well Cost was added to the EDT suite of applications for the first time in this release. For
the WELLPLAN application, the following enhancements were made:
Cementing
•
OptiCem™ software enhancements:
—
—
—
—
Update version to 6.1.4
Enhance Animation when mud cake is present
Recommend back pressure if float equipment fails
Mud Erodibility calculations enhanced when compressible or synthetic fluids
are present in the wellbore
Torque/Drag
•
WELLPLAN TDA includes a stretch calculation in its Summary Loads table which
shows stretch solely due to mechanical forces (weight/drag). WELLPLAN stretch
calculations have been enhanced to include stretch due to thermal expansion of
5000.1.7
Page 401 of 423
May 2010
Draft
Release 5000.1.1
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
materials in order to predict more realistic stretch. This will yield a true calculation
of the difference between drillers depth and wireline depth (compensated).
•
Options for entering Friction Factors in Torque Drag have been simplified. If data
from a previous version utilized User-Defined or Calibrated coefficients of friction,
these coefficients will automatically be input into the Hole Section Editor.
•
Geothermal Gradient dialog was added.
Hydraulics
Mud Pits added to Hydraulics Circulating System. This functionality provides the
option to calculate the flowing fluid temperature from the mud pit to the drillstring at
the surface using the mud tank geometry and environmental conditions such as
wind speed, ambient temperature.
•
Maximum Pump Power, Maximum Allowable Pump Rate, and Standpipe Pressure
were added to applicable Hydraulics modes for reference.
•
Minimum flowrate to clean hole added to Pressure Loss plot as a line of interest for
quick reference.
Surge
•
Optimize trip speed option was removed from Surge/Swab Operations Data. It is
now possible to use the Optimized Trip Schedule to view results for entire open
hole.
•
Surge/Swab Optimized Trip Schedule plot is enhanced to show Maximum and
Minimum Trip Speeds.
•
All the Transient Response Plots are grouped together.
•
Plots are enhanced to allow usage of MD/TVD, and EMW/PSI toggles, and legends
now display trip speeds.
Well Control
•
Well Control: Kill Sheet quick view results are enhanced to show the Kill Mud
Weight Details, with and without Trip Margin.
•
Well Control Plots are enhanced to show the Casing Burst and BOP Pressure
Ratings.
Stuck Pipe
•
Stuckpipe calculations were enhanced to show the Jar positioning.
5000.1.7
Page 402 of 423
May 2010
Draft
•
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
BHA
•
Overgauge field was removed from BHA modules. Use Volume Excess in the Hole
Section Editor to define the amount of washout.
Real Time
•
Real time hydraulics calculations were enhanced to support Mud Temperature
Effects and Back Pressure.
•
Real Time Plots were enhanced to configure the actual scatter data.
Draft
Reports
•
All reports have been organized to display tables in logical order and are
sequentially numbered.
•
All reports were updated to accommodate new changes, address outstanding
defects, and improve format.
General Engineering
•
Convert Depth/EMW is updated with Maximum Pore Pressure and Minimum
Fracture Pressure for engineering analysis.
•
PSI/EMW and MD/TVD toggles support across all of the engineering plots and
tables (within the application, Wall Plots).
•
Right-click copy to clipboard support for all the grid data.
•
Geothermal Gradient Plot added to Geothermal Gradient dialog.
•
WELLPLAN software status messages are Case-specific and color-coded to
denote Errors, Warnings, and Information.
•
Bit Specifications dialog is enhanced with Bi-Center bit parameters.
•
Simplified the design of the Hole Section Editor.
•
— The number of hole section types was simplified to Riser, Casing, and Open
Hole. If a Case created with an earlier version is opened using the 5000.1
version, any non-supported components will be treated as casings.
— Excess % is now used to represent an overgauge hole.
— A number of columns can be hidden by checking the Additional Columns box
on the Hole Section Editor.
Maximum Allowable Pump Rate added to Circulating System.
•
Enhanced the design of the Fluid Editor by presenting a Simplified Fluid Editor for
Solid Mechanics modules, and an Advanced Fluid Editor for Fluid Mechanics
modules.
5000.1.7
Page 403 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
•
A ‘Close All’ option was added to the File Menu, allowing the user to close several
open Cases at the same time.
•
Disable icons for modules that are not licensed.
•
Now supports negative string components in the String Editor.
•
Various engineering bug fixes were done.
Draft
5000.1.7
Page 404 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WELLPLAN Fixed Issues
The WELLPLAN issues fixed for 5000.1.0 through 5000.1.7 are described below.
Release 5000.1.7
The following issues were fixed for the 5000.1.7 release of WELLPLAN software.
Description
833765
Difference in load results for a “Tripping In” operation
833954
Differences in "Calculated Tripping In Hook Load (kip)" values in Manual
Friction Calibration plot and its data
Release 5000.1.6
The following issues were fixed for the 5000.1.6 release of WELLPLAN software.
Defect No.
Description
702772
Ability to model cuttings loading and temperature affects together
816981
WELLPLAN Kill Sheet report results does not match with calc. values
816983
Depth interval to check in KT mode is confusing as it is not depth
816984
Final density plot should not have lines for frac and pore as they wrongly
represent in the plot
828318
Hole Cleaning operations results change for the same input data
828946
Remove String ECD line from the ECD chart plot
828947
STU-Backoff Analysis, "Rotary Table Torque" wrong label
828949
Only ECD chart does not display and all other hydraulics results are okay
829295
Directory path truncated when viewing single or multiple slurries
829653
Removed the “top/bottom” stabilizer sections from the Advanced Mud
Motor details dialog
830602
WELLPLAN Toolbars changing position and order at random.
5000.1.7
Page 405 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.5
The following issues were fixed for the 5000.1.5 release of WELLPLAN software.
Description
782260
TDA centralizer placement calculation uses the 1/1 freq and joint making the TDA
calculation override the spacing from centralizer placement.
791337
Clicking OK after entering DB Credentials to local SQL Server 2005 causes
WELLPLAN to crash in jnilibu.dll.
793361
Pore pressure in the Pore Pressure Editor exceeded the limit of 1200 rows.
799855
Application crashes when selecting a Custom Bit catalog.
799859
Bit Nozzles: Application crashes when you click the Copy to String button.
800822
Operational plot generates errors when using a port collar in the string.
805884
WELLPLAN crashes when trying to open a catalog that contains data including
double quotes in a character field.
808661
Hydraulics Module, Security Failure accessing module without rights.
812990
Incorrect hole section defined in dual tubing design configuration.
812993
WELLPLAN ignores the presence of VIT pipe in the well configuration, which is OK;
however, pipes other than VIT shown to have problems defining the correct open
hole section length.
813617
Help button does not work on Picklist Editor.
815096
OpenWells-WELLPLAN integration: CD_HOLE_SECT.cof not coming from
OpenWells in WELLPLAN - create case from Daily Operations Daily Entry Form.
816587
In both R5000 and 2003.16.1, WELLPLAN report data within tables is not aligned
correctly within the boxes.
Draft
Defect No.
Release 5000.1.4
No WELLPLAN issues were fixed or have workarounds for the 5000.1.4 release.
Release 5000.1.3
No WELLPLAN issues were fixed or have workarounds for the 5000.1.3 release.
Release 5000.1.2
No WELLPLAN issues were fixed or have workarounds for the 5000.1.2 release.
5000.1.7
Page 406 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.1
No WELLPLAN issues were fixed or have workarounds for the 5000.1.1 release.
Release 5000.1.0
The following issues were fixed or have work-arounds for the 5000.1.0 release.
Draft
5000.1.7
Page 407 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
General Fixed Issues
Description
726666
WELLPLAN Schematic does not show correct depths with custom unit
set.
728769
The Status Message Toolbar can become greyed out when selecting a
Swab Surge (Steady State) Wall Plot Composer data box without
entering any input data. To re-activate the Status Message Toolbar,
close and re-open the WELLPLAN application.
743759
The String Editor will now set the top component(s) length to zero if the
string depth is less than the hole section depth.
747532
The toggle MD and EMW toolbars buttons will remove all frozen lines
from a plot. (A curve is “frozen” by right-clicking on the curve and
selecting Freeze Line.)
749011
When creating a design and case from OpenWells software, it is not
possible to select pore pressure or fracture gradient data.
751479
It is possible to create multiple fluids with the same name.
751851
Custom base fluid name and compressibility data is not imported with
the fluid library (*.lib.xml).
752214
Convergence angle/location should be exposed in the Well Explorer
for engineering applications
752443
When a Case is created, the first row (0 for MD, Inc, and Azi) of the
wellpath should not be editable.
752437
In a Citrix environment, an incorrect parameter error is thrown, and the
operation is aborted when importing a Caliper log from the local drive.
753796
Remove Tau0 from yield point description.
764205
Default file name of Library export file is not intuitive to users.
768007
Software crashes when using undereamer and checking diverter
through component percentage different than 75%.
772371
Crash when importing a workstring from a library after importing using
DEX™ software.
772539
The Well Explorer displays Russian characters as question marks.
773975
Bit TFA does not change when Jet nozzle row is deleted.
779899
Tab name is not correct when tab order is changed.
782311
Custom labels and descriptions entered using Russian characters in
the Data Dictionary are displayed as question marks.
Page 408 of 423
May 2010
Draft
5000.1.7
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Torque Drag Fixed Issues
Description
757751
For Tripping In operation (Using SOD's) drag chart torque does not
match with that of Normal analysis for Rigid Centralizers.
773646
Torque Drag Analysis Tortuosity Magnitude now allows 10 rows.
774165
WELLPLAN software will only take into account buoyancy effects
when the first survey point is defined at MSL as MD=0
774345
Abnormal program termination when focus is on the STF column in
TDA Load Summary and then the F2 key is clicked.
775739
The tension limit line in the effective tension plot in T&D module has a
limit of 2000 kips.
777588
Bucking lines are not displayed on the Effective Tension plots.
781701
Torque results for Drag Chart analysis using standoff devices may
change slightly as a result of modified calculation.
Hydraulics Fixed Issues
Defect No.
Description
732200
MD Calculation Interval was increased to 500 rows/ intervals.
773542
In the Hydraulics module, the ECD and circulating pressure
calculations were not performed correctly when an undereamer was in
the string.
780488
For some data sets, the Transport Analysis Data dialog is validating
against the wrong fields.
Well Control Fixed Issues
5000.1.7
Defect No.
Description
772593
Kick calculation model showing wrong depth for pore pressure and
fracture lines of interest.
778074
Well Control Influx Volume results may change because volume
interval calculation increments are now based on barrels.
Page 409 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Surge Fixed Issues
Description
730213
Stand frequency scaling improved in trip schedule when there is no
variance over trip schedule.
731477
When using the Surge Module, there is an abnormal software
termination if one of the moving pipe depths is close to the additional
Depth of Interest.
744572
SrgGraphUI error is thrown on activating Surge module or report the
very first time on a new database. Workaround: Close and re-open the
case.
753423
When using the Surge module, if the Depth of Interest equals the Shoe
Depth, the Depth of Interest will be increased five (5) feet and
calculations will proceed. A warning message will also be displayed in
the Status Messages area.
768337
Swab/Surge results are not calculated when an undereamer is
included in the string.
772322
Inaccurate results when viewing plots using EMW when the units class
for pressure is changed to psig.
782255
Accuracy improved for Optimized Trip Speed using oil based muds.
OptiCem Software Fixed Issues
5000.1.7
Defect No.
Description
748745
In OptiCem software, the Quality Surface plot is missing data for some
data sets.
748754
Displaying an animation plot on top of another animation plot that has
been fully played may take a significant amount of time.
749373
If you no longer have the centralizer that was used when the
centralizer data was transferred to the standoff devices (for Torque
Drag Analysis), a warning is displayed.
784003
For some data sets using synthetic mud, the circulating pressure is
over-predicted on the Circulating Pressure and Density plot when
using the erodibility option.
Page 410 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Stuck Pipe Fixed Issues
Defect No.
Description
769620
Display the Stuck position (below or above the jar centerline) as quick
view in the analysis results.
Real Time Fixed Issues
Description
750232
Mnemonics defined are not transferred via xml files for the Real Time
cases.
778578
Real Time ECD at TD and the standpipe pressure results do not match
the results from the Hydraulics module.
782345
The calculated ECD at TD using the Real Time Module does not match
the ECD calculated using the Hydraulics Module (Pump Rate Fixed).
Reports Fixed Issues
5000.1.7
Defect No.
Description
730691
On rare occasions, data may not display on a report launched for a
non-active module. Workaround: Activate module, trigger calculations,
and then relaunch reports relevant to the module.
730942
Foam flag added to fluid rheology data block in report for Generalized
Herschel-Bulkley fluids to indicate when fluid is foamed.
739399
Random abnormal terminations when launching the reports the first
time resolved.
740616
Occasionally, it takes a long while to launch the Pressure losses report
the very first time. Workaround: Launching the report second time does
not take as long.
Page 411 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
WELLPLAN Known Issues
The following WELLPLAN known issues for releases 5000.1.0 through 5000.1.7 are
described below.
Release 5000.1.7
There are no additional WELLPLAN known issues for the 5000.1.7 release.
Release 5000.1.6
Draft
Defect No.
Description
830796
User will run into an import failed error message while importing
historical XML files (from 2003.16.1.14 and later) due to a real-time
depth interval field. The import is working properly; user needs to
refresh the Well Explorer and continue working with the Case.
Release 5000.1.5
There are no additional WELLPLAN known issues for the 5000.1.5 release.
Release 5000.1.4
There are no additional WELLPLAN known issues for the 5000.1.4 release.
Release 5000.1.3
There are no additional WELLPLAN known issues for the 5000.1.3 release.
Release 5000.1.2
There are no additional WELLPLAN known issues for the 5000.1.2 release.
Release 5000.1.1
There are no additional WELLPLAN known issues for the 5000.1.1 release.
5000.1.7
Page 412 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Release 5000.1.0
The following are WELLPLAN known issues for the 5000.1.0 release.
Draft
5000.1.7
Page 413 of 423
May 2010
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
General Known issues
Description
769678
VAM catalogs are not up to date with vendor's list.
776472
Duplicates in Casing/Tubing catalog (Halliburton Redbook Casing) due
to Body ID not being added to list of catalog.
778580
Hole Sections incorrectly populated in WELLPLAN software with
Create Cases from Casing Design feature when BHA length is
designed greater than Casing length in PROFILE.
780699
Wall Plots tabs can only be deleted from the bottom of the list in Tab
Manager.
782086
The kick off depth is not refreshed correctly in wellbore properties
unless WELLPLAN software is closed and reopened.
783590
Radio buttons on the Mud Pits dialog are occasionally disabled when
user does not tab out of last focused field.
Torque Drag Known issues
Defect No.
Description
782260
Torque Drag centralizer placement calculation uses the 1/1 frequency
per joint making the Torque Drag calculation override the spacing from
centralizer placement.
Hydraulics Known Issues
5000.1.7
Defect No.
Description
782603
Hydraulics ECD vs Depth and SPP vs Depth in Drag Chart results do
not match when changing the base type from Synthetic to water and
back to Synthetic.
785348 & 785350
Occasionally the Pressure Loss plot (if present in active view) changes
to a plot without grids or crashes when rheology model is changed
from Bingham Plastic to Herschel Bulkley or Generalized Herschel
Bulkley model and only 2 Fann data points are defined. Workaround:
Define three (3) Fann data readings, which are needed for Herschel
Bulkley and Generalized Herschel Bulkley Rheology models, before
changing the rheology model.
Page 414 of 423
May 2010
Draft
Defect No.
Enhancements, Fixed Issues, and Known Issues
EDT™ Release Notes
Go To “What’s In This Release?”
Well Control Known Issues
Defect No.
Description
730584
Map pore pressure data from kick analysis report to a new row in kick
case created from OpenWells® software in WELLPLAN software.
782613
Mud Pits are shown in Well Control module, even though they are not
used in this module.
Surge Known Issues
Description
781978
Reciprocation Mode calculation is not based on the acceleration and
deceleration fields.
783985
Occasionally a com object error occurs the first time Surge results are
calculated.
OptiCem Known issues
Defect No.
Description
775970
Importing and saving some OptiCem (OTC) file via CITRIX ICA
interface causes abnormal software termination.
Reports Known Issues
5000.1.7
Defect No.
Description
780657
MD/TVD and EMW/PSI toggle buttons will not have any effect on the
tables in the reports.
782256
Occasionally reports may take long time to generate. This usually
happens on larger reports.
782470
WELLPLAN reports exported to Microsoft Word are now 40% larger in
size than in the previous releases.
Page 415 of 423
May 2010
Draft
Defect No.
International Trade Compliance
EDT™ Release Notes
Go To “What’s In This Release?”
International Trade Compliance
This application is manufactured or designed using U.S. origin technology and is therefore
subject to the export control laws of the United States. Any use or further disposition of
such items is subject to U.S. law. Exports from the United States and any re-export
thereafter may require a formal export license authorization from the government. If there
are doubts about the requirements of the applicable law, it is recommended that the buyer
obtain qualified legal advice. These items cannot be used in the design, production, use,
or storage of chemical, biological, or nuclear weapons, or missiles of any kind.
Under the U.S. Export Administration Regulations (EAR), the U.S. Government assigns
your organization or client, as exporter/importer of record, responsibility for determining
the correct authorization for the item at the time of export/import. Restrictions may apply
to shipments based on the products, the customer, or the country of destination, and an
export license may be required by the Department of Commerce prior to shipment. The
U.S. Bureau of Industry and Security provides a website to assist you with determining the
need for a license and with information regarding where to obtain help.
The URL is: http://www.bis.doc.gov
Definitions
CCATS (Commodity Classification Automated Tracking System) - the tracking number
assigned by the U.S. Bureau of Industry and Security (BIS) to products formally reviewed
and classified by the government. The CCATS provides information concerning export/reexport authorizations, available exceptions, and conditions.
ECCN - Export Control Classification Number - The ECCN is an alpha-numeric code, e.g.,
3A001, that describes a particular item or type of item, and shows the controls placed on
that item. The CCL (Commerce Control List) is divided into ten broad categories, and each
category is further subdivided into five product groups. The CCL is available on the EAR
Website.
5000.1.7
Page 416 of 423
May 2010
Draft
The ECCN's provided in Release Notes represent Landmark Graphics' opinion of the
correct classification for the product today (based on the original software and/or original
hardware). Classifications are subject to change. If you have any questions or need
assistance please contact us at [email protected]
International Trade Compliance
EDT™ Release Notes
Go To “What’s In This Release?”
Product/Component/R5000
ECCN
Number
License
CCATS
Number
Last Date
Updated
Engineer’s Data Model (EDM)
5D002
ENC
G060075
3/29/2010
Engineer’s Data Model Software
Development Kit (EDM SDK)
5D002
ENC
G060075
3/29/2010
5000.1.7
Page 417 of 423
May 2010
Draft
The ECCN number, License Type, and the CCATS Numbers for this product are included
in the table below. Also included is the date the table was last updated.
Contacting Landmark Customer Support
EDT™ Release Notes
Go To “What’s In This Release?”
Contacting Landmark Customer Support
Landmark software operates Technical Assistance Centers (TACs) in Australia, the
United Kingdom, and the United States. Additional support is also provided through
regional support offices around the world.
the “Support Via Web Portal” section
•
the “Technical Assistance Centers” section
•
the “Regional Offices” section
•
the “Helpful Links” section
Draft
•
Support Via Web Portal
Support information is always available on the Landmark Customer Support internet
page. You can also submit a support request directly to Landmark Customer Support
though the Landmark Customer Support Portal:
http://css.lgc.com/InfoCenter/index?page=home
To request support in the Landmark Customer Support Portal:
1. In the PIN and Password text boxes in the Please Sign In area, enter your registered
personal identification number and password.
2. Click the Sign In button.
3. In the Case & Defect Information area, click the Create A New Case link.
4. In the Create Case area, fill in the necessary information. Provide details about your
technical concern, including any error messages, the workflow steps where the
problem occurred, and attachments of screen shots that display the problem. To help
understand the concern, you can also attach other files too, such as example data
files.
5. Click the Submit button. A support analyst in the nearest Technical Assistance
Center will respond to your request.
5000.1.7
Page 418 of 423
May 2010
Contacting Landmark Customer Support
EDT™ Release Notes
Go To “What’s In This Release?”
Technical Assistance Centers
61-8-9481-4488 (Perth, Australia)
Toll Free 1-800-448-488
Fax: 61-8-9481-1580
Email: [email protected]
Europe, Africa, Middle East
9:00 am - 5:30 pm Local Time
Monday - Friday, excluding holidays
44-1372-868686 (Leatherhead, UK)
Fax: 44-1224-723260 (Aberdeen, UK)
Fax: 44-1372-868601 (Leatherhead, UK)
Email: [email protected]
Latin America
(Spanish, Portuguese, English)
7:00 am - 5:00 pm Local Time
713-839-3405 (Houston, TX, USA)
Fax: 713-839-3646
Email: [email protected]
North America
7:30 am - 5:30 pm Central Standard Time
Monday - Friday, excluding holidays
713-839-2200 (Houston, TX, USA)
Toll Free 1-877-435-7542
(1-877-HELP-LGC)
Fax: 713-839-2168
Email: [email protected]
Draft
Asia, Pacific
8:00 am - 5:00 pm Local Time
Monday-Friday, excluding holidays
Regional Offices
For contact information for regional offices, see the Contact Support page located at:
http://css.lgc.com/InfoCenter/index?page=contact&section=contact
If problems cannot be resolved at the regional level, an escalation team is called to
resolve your incidents quickly.
5000.1.7
Page 419 of 423
May 2010
Contacting Landmark Customer Support
EDT™ Release Notes
Go To “What’s In This Release?”
Helpful Links
Website Address
Landmark Software & Services home page
http://www.halliburton.com/landmark
Landmark Support Portal
http://css.lgc.com/InfoCenter/index?page=home
Oracle home page
http://www.oracle.com
FLEXNet Publisher (Flexera Software, Inc.)
http://www.flexerasoftware.com
Microsoft SQL Server home page
http://www.microsoft.com/sqlserver
Adobe Acrobat Reader
http://www.adobe.com
Microsoft SQL Server Express home page
http://www.microsoft.com/express/sql
5000.1.7
Page 420 of 423
Draft
Name
May 2010
Contacting Landmark Customer Support
EDT™ Release Notes
Go To “What’s In This Release?”
© 2010 Halliburton
All Rights Reserved Worldwide
This publication has been provided pursuant to an agreement containing restrictions on its use. The publication is also
protected by Federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed,
stored in a retrieval system, or translated into any human or computer language, in any form or by any means,
electronic, magnetic, manual, or otherwise, or disclosed to third parties without the express written permission of:
Halliburton | Landmark Software & Services
2107 CityWest Blvd., Building 2, Houston, Texas 77042-3051, USA
P.O. Box 42806, Houston, Texas 77242, USA
Phone:713-839-2000, FAX: 713-839-2015
Internet: www.halliburton.com/landmark
5000.1.7
Page 421 of 423
May 2010
Draft
Trademarks
3D Drill View, 3D Drill View KM, 3D Surveillance, 3DFS, 3DView, Active Field Surveillance, Active Reservoir
Surveillance, Adaptive Mesh Refining, ADC, Advanced Data Transfer, Analysis Model Layering, ARIES, ARIES
DecisionSuite, Asset Data Mining, Asset Decision Solutions, Asset Development Center, Asset Development Centre,
Asset Journal, Asset Performance, AssetConnect, AssetConnect Enterprise , AssetConnect Enterprise Express ,
AssetConnect Expert , AssetDirector, AssetJournal, AssetLink, AssetLink Advisor, AssetLink Director, AssetLink
Observer, AssetObserver, AssetObserver Advisor, AssetOptimizer, AssetPlanner, AssetPredictor, AssetSolver,
AssetSolver Online, AssetView, AssetView 2D, AssetView 3D, BLITZPAK, CasingLife, CasingSeat, CDS Connect,
Channel Trim, COMPASS, Contract Generation, Corporate Data Archiver, Corporate Data Store, Data Analyzer,
DataManager, DataStar, DBPlot, Decision Management System, DecisionSpace, DecisionSpace 3D Drill View,
DecisionSpace 3D Drill View KM, DecisionSpace AssetLink, DecisionSpace AssetPlanner, DecisionSpace
AssetSolver, DecisionSpace Atomic Meshing, DecisionSpace Nexus, DecisionSpace Reservoir, DecisionSuite, Deeper
Knowledge. Broader Understanding., Depth Team, Depth Team Explorer, Depth Team Express, Depth Team Extreme,
Depth Team Interpreter, DepthTeam, DepthTeam Explorer, DepthTeam Express, DepthTeam Extreme, DepthTeam
Interpreter, Design, Desktop Navigator, DESKTOPPVT, DESKTOPVIP, DEX, DIMS, Discovery, Discovery 3D,
Discovery Asset, Discovery Framebuilder, Discovery PowerStation, DMS, Drillability Suite, Drilling Desktop, DrillModel,
Drill-to-the-Earth-Model, Drillworks, Drillworks ConnectML, DSS, Dynamic Reservoir Management, Dynamic
Surveillance System, EarthCube, EDM, EDM AutoSync, EDT, eLandmark, Engineer's Data Model, Engineer's Desktop,
Engineer's Link, ESP, Event Similarity Prediction, ezFault, ezModel, ezSurface, ezTracker, ezTracker2D, FastTrack,
Field Scenario Planner, FieldPlan, For Production, FrameBuilder, FZAP!, GeoAtlas, GeoDataLoad, GeoGraphix,
GeoGraphix Exploration System, GeoLink, Geometric Kernel, GeoProbe, GeoProbe GF DataServer, GeoSmith, GES,
GES97, GESXplorer, GMAplus, GMI Imager, Grid3D, GRIDGENR, H. Clean, Handheld Field Operator, HHFO, High
Science Simplified, Horizon Generation, I2 Enterprise, iDIMS, Infrastructure, Iso Core, IsoMap, iWellFile,
KnowledgeSource, Landmark (as a service), Landmark (as software), Landmark Decision Center, Landmark Logo and
Design, Landscape, Large Model, Lattix, LeaseMap, LogEdit, LogM, LogPrep, Magic Earth, Make Great Decisions,
MathPack, MDS Connect, MicroTopology, MIMIC, MIMIC+, Model Builder, NETool, Nexus (as a service), Nexus (as
software), Nexus View, Object MP, OpenBooks, OpenJournal, OpenSGM, OpenVision, OpenWells, OpenWire,
OpenWire Client, OpenWire Server, OpenWorks, OpenWorks Development Kit, OpenWorks Production, OpenWorks
Well File, PAL, ParallelVIP, Parametric Modeling, PetroBank, PetroBank Explorer , PetroBank Master Data Store,
PetroStor, PetroWorks, PetroWorks Asset, PetroWorks Pro, PetroWorks ULTRA, PlotView, Point Gridding Plus,
Pointing Dispatcher, PostStack, PostStack ESP, PostStack Family, Power Interpretation, PowerCalculator,
PowerExplorer, PowerExplorer Connect, PowerGrid, PowerHub, PowerModel, PowerView, PrecisionTarget, Presgraf,
PressWorks, PRIZM, Production, Production Asset Manager, PROFILE, Project Administrator, ProMAGIC, ProMAGIC
Connect, ProMAGIC Server, ProMAX, ProMAX 2D, ProMax 3D, ProMAX 3DPSDM, ProMAX 4D, ProMAX Family,
ProMAX MVA, ProMAX VSP, pSTAx, Query Builder, Quick, Quick+, QUICKDIF, Quickwell, Quickwell+, Quiklog,
QUIKRAY, QUIKSHOT, QUIKVSP, RAVE, RAYMAP, RAYMAP+, Real Freedom, Real Time Asset Management
Center, Real Time Decision Center, Real Time Operations Center, Real Time Production Surveillance, Real Time
Surveillance, Realtime View, Reference Data Manager, Reservoir, Reservoir Framework Builder, RESev, ResMap,
RTOC, SCAN, SeisCube, SeisMap, SeisModel, SeisSpace, SeisVision, SeisWell, SeisWorks, SeisWorks 2D,
SeisWorks 3D, SeisWorks PowerCalculator , SeisWorks PowerJournal , SeisWorks PowerSection, SeisWorks
PowerView, SeisXchange, Semblance Computation and Analysis, Sierra Family, SigmaView, SimConnect,
SimConvert, SimDataStudio, SimResults, SimResults+, SimResults+3D, SIVA+, SLAM, SmartFlow, smartSECTION,
Spatializer, SpecDecomp, StrataAmp, StrataMap, StrataModel, StrataSim, StratWorks, StratWorks 3D, StreamCalc,
Contacting Landmark Customer Support
EDT™ Release Notes
Go To “What’s In This Release?”
StressCheck, STRUCT, Structure Cube, Surf & Connect, SynTool, System Start for Servers, SystemStart, SystemStart
for Clients, SystemStart for Servers, SystemStart for Storage, Tanks & Tubes, TDQ, Team Workspace, TERAS, TGrid,
The Engineer's DeskTop, Total Drilling Performance, TOW/cs, TOW/cs Revenue Interface, TracPlanner, TracPlanner
Xpress, Trend Form Gridding, Trimmed Grid, Turbo Synthetics, VESPA, VESPA+, VIP, VIP-COMP, VIP-CORE,
VIPDataStudio, VIP-DUAL, VIP-ENCORE, VIP-EXECUTIVE, VIP-Local Grid Refinement, VIP-THERM, WavX, Web
Editor, Well Cost, WellDirect, Well H. Clean, Well Seismic Fusion, Wellbase, Wellbore Planner, Wellbore Planner
Connect, WELLCAT, WELLPLAN, WellSolver, WellXchange, WOW, Xsection, You're in Control. Experience the
difference, ZAP!, and ZMAP Plus are trademarks, registered trademarks, or service marks of Halliburton.
All other trademarks, service marks, and product or service names are the trademarks or names of their respective
owners.
[Installdir]\Documentation\Third_Party.pdf
Disclaimer
The programs and documentation may provide links to external web sites and access to content, products, and services
from third parties. Halliburton is not responsible for the availability of, or any content provided on, third party web
sites. You bear all risks associated with the use of such content. If you choose to purchase any products or services
from a third party, the relationship is directly between you and the third party. Halliburton is not responsible for: (a)
the quality of third party products or services; or (b) fulfilling any of the terms of the agreement with the third party,
including delivery of products or services and warranty obligations related to purchased products or services.
Halliburton is not responsible for any loss or damage of any sort that you may incur from dealing with any third party.
5000.1.7
Page 422 of 423
May 2010
Draft
Note
The information contained in this document is subject to change without notice and should not be construed as a
commitment by Halliburton. Halliburton assumes no responsibility for any error that may appear in this manual. Some
states or jurisdictions do not allow disclaimer of expressed or implied warranties in certain transactions; therefore, this
statement may not apply to you.
Contacting Landmark Customer Support
EDT™ Release Notes
Go To “What’s In This Release?”
Draft
5000.1.7
Page 423 of 423
May 2010

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project