R410A Split Series
OWNER'S MANUAL
MODEL
FTXV25AV1
FTXV35AV1
FTXV50AV1
FTXV60AV1
RXV25AV1
RXV35AV1
RXV50AV1
RXV60AV1
English
Disposal requirements
Your product and the batteries supplied with the controller are marked with this symbol.
This symbol means that electrical and electronic products and batteries shall not be mixed
with unsorted household waste. For batteries, a chemical symbol can be printed beneath
the symbol. This chemical symbol means that the battery contains a heavy metal above
a certain concentration. Possible chemical symbols are:
■ Pb: lead (>0.004%)
Do not try to dismantle the system yourself: the dismantling of the product, treatment of the refrigerant,
of oil and of other parts must be done by a qualified installer in accordance with relevant local and national
legislation. Units and waste batteries must be treated at a specialized treatment facility for re-use,
recycling and recovery. By ensuring correct disposal, you will help to prevent potential negative
consequences for the environment and human health. Please contact the installer or local authority
for more information.
Content
Operation Notices
Safety Precautions..................................................................................................1
Parts Name.............................................................................................................3
Installation Notice
Installation dimension diagram ...............................................................................4
Tools for installation................................................................................................5
Selection of installation location..............................................................................5
Requirements for electric connection .....................................................................6
Installation
Installation of indoor unit.........................................................................................7
Installation of outdoor unit.....................................................................................12
Vacuum pumping..................................................................................................15
Leakage detection ................................................................................................15
Check after installation .........................................................................................16
English
Test and operation
Test operation.......................................................................................................16
Attachment
Configuration of connection pipe ..........................................................................17
Pipe expanding method ........................................................................................18
Screen Operation Guide
Buttons on remote controller.................................................................................19
Introduction to icons on display screen.................................................................19
Introduction to buttons on remote controller .........................................................20
Introduction to functions of combination buttons ..................................................23
Operation guide ....................................................................................................24
Replacement of batteries in remote controller ......................................................24
Emergency operation............................................................................................25
Maintenance
Cleaning and Maintenance ...................................................................................25
Malfunction
Malfunction analysis .............................................................................................28
Wiring....................................................................................................................32
Safety Precautions
• The precautions described herein are classified as WARNING and CAUTION. They both contain important information
regarding safety. Be sure to observe all precautions without fail.
• Meaning of WARNING and CAUTION notices
WARNING ..........Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION ...........Failure to observe these instructions properly may result in property damage or personal injury,
which may be serious depending on the circumstances.
• The safety marks shown in this manual have the following meanings:
Be sure to follow the instructions.
Be sure to establish an earth connection.
Never attempt.
• After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate
the air conditioner and take care of it with the aid of the operation manual.
• The English text is the original instruction. Other languages are translations of the original instructions.
WARNING
• Ask your dealer or qualified personnel to carry out installation work.
Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.
• Install the air conditioner in accordance with the instructions in this installation manual.
Improper installation may result in water leakage, electric shocks or fire.
Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.
• Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equipment falling and causing injury.
• Electrical work must be performed in accordance with relevant local and national regulations and with instructions
in this installation manual. Be sure to use a dedicated power supply circuit only.
Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire.
• Use a cable of suitable length.
Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire.
• Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal
connections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or fire.
• When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires
so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals.
• If refrigerant gas leaks during installation, ventilate the area immediately.
Toxic gas may be produced if the refrigerant comes into contact with fire.
• After completing installation, check for refrigerant gas leakage.
Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater,
stove or cooker.
• When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air,
and use only the specified refrigerant (R410A).
The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even
injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal pressure in the
refrigeration cycle, which may result in equipment damage and even injury.
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.
• Be sure to earth the air conditioner.
Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks or fire.
• Do not touch any electronic component or terminal when the machine is running, stopping or has been powered off
for less than 30 minutes to prevent the risk of electric shock!
1
English
• Be sure to use only the specified accessories and parts for installation work.
CAUTION
• Do not install the air conditioner at any place where there is a danger of flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
• While following the instructions in this installation manual, install drain piping to ensure proper drainage and insulate
piping to prevent condensation.
Improper drain piping may result in indoor water leakage and property damage.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.
• Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals.
Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the
unit clean.
• This appliance is intended to be used by expert or trained users in shops, in light industry and on farms,
or for commercial and household use by lay persons.
• Sound pressure level is less than 70 dB(A).
• NOTE: Motor ground only applies to the iron shell motor.
English
• This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children shall be supervised to ensure that they do not play with the appliance.
Working temperature range
Maximum cooling
Maximum heating
Indoor side DB/WB(°C)
32/23
27/-
Outdoor side DB/WB(°C)
43/26
24/18
● The operating temperature range (outdoor temperature) is 18 - 43°C for cooling
and -7 - 24°C for heating operation.
2
Parts Name
Indoor Unit
air inlet
panel
filter
aux. button
horizontal louver
cooling
indicator
receiver
window
air outlet
heating
indicator
power
indicator
English
display
TURBO
ON/OFF
MODE
+
SAVE
-
FAN
SWING
SLEEP
TIMER
LIGHT
X-FAN
remote controller
Outdoor Unit
air inlet
handle
air outlet
3
At least 15cm
Space to the ceiling
Installation dimension diagram
Space to the wall
At least 15cm
At least 15cm
ac
the
o
tr
bs
uc
tio
n
Space to the obstruction
Sp
o
et
lea
the
to n
e
ac ctio
Sp stru
st
ob
lea
At cm
30
At least 50cm
English
At
Space to the floor
cm
00
3
st
Drainage pipe
At least 30cm
Space to th
Sp
a
t
ce
ot
h
eo
At least 250cm
Space to the wall
e wall
tr
bs
At
uc
tio
n
At least 50cm
cm
00
2
st
Space to the
obstruction
lea
4
Tools for installation
1 Level meter
4 Drill head
7 Open-end wrench
10 Vacuum pump
13 Inner hexagon spanner
Note:
2 Screw driver
3 Impact drill
5 Pipe expander
6 Torque wrench
8 Pipe cutter
9 Leakage detector
11 Pressure meter
12 Universal meter
14 Measuring tape
● Please contact the local agent for installation.
● Don’t use unqualified power cord.
Basic requirement
Installing the unit in the following places
may cause malfunction. If it is
unavoidable, please consult the
local dealer:
1. The place with strong heat sources,
vapors, flammable or explosive gas,
or volatile objects spread in the air.
2. The place with high-frequency
devices (such as welding machine,
medical equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special
circumstances.
7. The appliance shall not be installed in
the laundry.
Indoor unit
1. There should be no obstruction near
air inlet and air outlet.
2. Select a location where the
condensation water can be dispersed
easily and won't affect other people.
3. Select a location which is convenient
to connect the indoor unit and near the
power socket.
4. Select a location which is out of reach
for children.
5. The location should be able to
withstand the weight of indoor unit and
won't increase noise and vibration.
6. The appliance must be installed 2.5m
above floor
7. Don't install the indoor unit right above
the electric appliance.
8. Please try your best to keep away
from fluorescent lamp.
Outdoor unit
1. Select a location where the noise and outflow air emitted by the outdoor unit will
not affect the neighborhood.
2. The location should be well ventilated and dry, in which the outdoor unit won't be
exposed directly to sunlight or strong wind.
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirements of installation dimension
diagram.
5. Select a location which is out of reach for children and far away from animals or
plants.If it is unavoidable, please add the fence for safety purpose.
5
English
Selection of installation location
Requirements for electric connection
English
Safety precaution
1. The electric safety regulations must be followed when installing the unit.
2. According to the local safety regulations, use qualified power supply circuit
and earth leakage circuit breaker.
3. Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring may result in electric shock, fire hazard
or malfunction. Please install proper power supply cables before using the air
conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
6. Do not put through the power before finishing installation.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid hazard.
8. The temperature of refrigerant circuit will be high, please keep the interconnection
cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
Grounding requirement
1. The air conditioner is the first class electric appliance. It must be properly
grounded with specialized grounding device by a professional. Please make sure
it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used for
other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
all poles should be connected in fixed wiring.
6. Be sure to install an earth leakage breaker capable of handling maximum rated
current. (One that can handle higher harmonics.)
6
Installation of indoor unit
Step one: choosing installation location
Recommend the installation location to the client and then confirm it with the client.
Step two: install wall-mounting frame
Step three: open piping hole
1. Choose the position of piping hole according to the direction of outlet pipe.
The position of piping hole should be a little lower than the wall-mounted frame,
shown as below.
Wall
Space
to the
wall
above
150mm
Level meter
Mark in the middle of it
Wall
Space
to the
wall
above
150mm
Right
Left
ø55mm or ø70mm
ø55mm or ø70mm
(Rear piping hole)
(Rear piping hole)
2. Open a piping hole with the diameter of Ø55 or Ø70 on the selected outlet pipe
position. In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10°.
7
English
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
level meter and then point out the screws fixing holes on the wall.
2. Drill the screw fixing holes on the wall with impact drill (the specification of drill
head should be the same as the plastic expansion particle) and then fill the plastic
expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
then check if the frame is firmly installed by pulling the frame. If the plastic
expansion particle is loose, please drill another fixing hole nearby.
Installation of indoor unit
Piping hole
Model
Ø55
Cooling capacity < 6000W
Ø70
Cooling capacity ≥ 6000W
Note:
● Pay attention to dust prevention and
take relevant safety measures when
opening the hole.
● The plastic expansion particles are
not provided and should be bought
locally.
ø55/
ø70
5-10
English
Step four: outlet pipe
2. When selecting leading out the
pipe from left or right, please cut off
the corresponding hole on the
bottom case.
1. The pipe can be led out in the
direction of right, rear right, left
or rear left.
left
right
left
rear right
right
rear left
cut off
the hole
Step five: connect the pipe of indoor unit
1. Aim the pipe joint at the corresponding
bellmouth.
pipe joint
2. Pretightening the union nut with hand.
union nut
pipe
3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten
the union nut with torque wrench.
8
Installation of indoor unit
open-end
wrench
union nut
torque wrench
pipe
indoor pipe
Hex nut diameter Tightening torque (N·m)
Ø6
15~20
Ø 9.52
30~40
Ø 12
40~55
Ø 16
60~65
Ø 19
70~75
4. Wrap the indoor pipe and joint of
connection pipe with insulating pipe,
and then wrap it with tape.
English
insulating pipe
Step six: install drain hose
1. Connect the drain hose to the outlet pipe of
indoor unit.
outlet pipe
drain hose
2. Bind the joint with tape.
tape
outlet
pipe
Note:
● Add insulating pipe in the indoor
drain hose in order to prevent
condensation.
● The plastic expansion particles
are not provided.
drain hose
drain hose
insulating pipe
Step seven: connect wire of indoor unit
panel
screw
1. Open the panel, remove the screw on
the wiring cover and then take down
the cover.
wiring cover
9
Installation of indoor unit
2. Make the power connection wire go
through the cable-cross hole at the back
of indoor unit and then pull it out from the
front side.
cablecross hole
power connection
wire
3. Remove the wire clip; connect the power
connection wire to the wiring terminal
according to the color; tighten the screw
and then fix the power connection wire
with wire clip.
wiring board
Outdoor unit connection
(for reference)
3
English
N(1) 2
grounding
wire
N(1)
2
3
blue black brown
yellowgreen
wire clip
Note: the wiring board is for reference only,
please refer to the actual one.
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Note:
● All wires of indoor unit and outdoor unit should be connected by a professional.
● If the length of power connection wire is insufficient (see table below), please
contact the supplier for a new one. Avoid extending the wire by yourself.
Class:
Length of Connecting Wire (mm)
25
1800
35
1800
50
1800
60
1800
● A circuit breaker must be installed for the air conditioner in serial connection.
10
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power
cord and drain hose with the band.
indoor unit
connection pipe
drain hose
band
indoor and
outdoor power cord
gas
pipe
3. Bind them evenly.
4. The liquid pipe and gas pipe should
be bound separately at the end.
Note:
● The power cord and control wire
can't be crossed or winding.
● The drain hose should be bound
at the bottom.
band
drain hose
2. Reserve a certain length of drain hose
and power cord for installation when
binding them. When binding to
a certain degree, separate the indoor
power and then separate the drain
hose.
Step nine: hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the
wall hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
indoor
wall pipe
upper hook
outdoor
sealing gum
lower hook of
wall-mounted frame
Note:
● Do not bend the drain hose too excessively in order to prevent blocking.
11
English
indoor power cord
liquid pipe
Installation of outdoor unit
Step one: fix the support of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
English
Note:
● Take sufficient protective measurements
when installing outdoor unit.
● Make sure the support can withstand at
least four times of the unit weight.
● The outdoor unit should be installed at least
3cm above the floor in order to install drain
joint.
● For the unit with cooling capacity of 2300W
~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10000W
~16000W, 10 expansion screws are
needed.
Step two: install drain joint
(Only for cooling and heating
unit)
Step three: fix outdoor unit
1. Place the outdoor unit on the
support.
2. Fix the foot holes of outdoor unit
with bolts.
1. Connect the outdoor drain joint into
the hole on the chassis, as shown in
the picture below.
2. Connect the drain hose into the
drain vent.
drain vent
Drain hose
at least 3cm above the floor
foot holes
foot holes
chassis
outdoor drain joint
12
Installation of outdoor unit
Step four: connect indoor and outdoor pipes
1. Remove the screw on the right
handle of outdoor unit and then
remove the handle.
3. Pretightening the union nut with
hand.
pipe joint
screw
yellowgreen
handle
4. Tighten the union nut with torque
wrench by referring to the sheet
below.
Hex nut diameter
liquid pipe
Ø6
Ø 9.52
Ø 12
Ø 16
Ø 19
gas pipe
liquid
valve
gas valve
Tightening torque
(N·m)
15~20
30~40
40~55
60~65
70~75
Step five: connect outdoor electric wire
1. Remove the wire clip; connect the
power connection wire and signal
control wire (only for cooling and
heating unit) to the wiring terminal
according to the color; fix them with
screws.
wiring board
Indoor unit connection
(for reference)
grounding
wire
blue
N(1) 2
handle
3
wire clip
13
black brown
yellowgreen
English
2. Remove the screw cap of valve and
aim the pipe joint at the bellmouth of
pipe.
union nut
Installation of outdoor unit
2. Fix the power connection wire and signal control wire with wire clip (only for
cooling and heating unit).
Note:
● After tightening the screw, pull the power cord slightly to check if it is firm.
Step six: neaten the pipes
English
1. The pipes should be placed along the wall,
bent reasonably and hidden possibly. Min.
semidiameter of bending the pipe is 10cm.
2. If the outdoor unit is higher than the wall
hole, you must set a U-shaped curve in the
pipe before pipe goes into the room, in
order to prevent rain from getting into the
room.
wall
U-shaped curve
drain hose
Note:
● The through-wall height of drain
hose shouldn't be higher than the
outlet pipe hole of indoor unit.
● Slant the drain hose slightly
downwards. The drain hose can't be
curved, raised and fluctuant, etc.
the drain hose
can’t point
upwards
The drain hose can’t be fluctulant
● The water outlet can't be placed in
water in order to drain smoothly.
The drain hose
can’t be
fluctulant
The water outlet
can’t be placed in
water
14
The water
outlet can’t
be fluctulant
Vacuum pumping
1. Remove the valve caps
on the liquid valve and
piezometer
liquid valve
Lo
Hi
gas valve and the nut of
refrigerant charging vent.
gas valve
2. Connect the charging
valve cap
hose of piezometer to
refrigerant charging
the refrigerant charging vent
vent of gas valve and
nut of refrigerant
charging vent
then connect the other
charging hose to the
vacuum pump
vacuum pump.
3. Open the piezometer
completely and operate
inner hexagon
for 10-15min to check if
spanner
the pressure of
piezometer remains
close
in -0.1MPa.
open
4. Close the vacuum pump
and maintain this status
for 1-2min to check if the
pressure of piezometer
remains in -0.1MPa.
If the pressure decreases, there may be leakage.
5. Remove the piezometer, open the valve core of liquid valve and gas valve
completely with inner hexagon spanner.
6. Tighten the screw caps of valves and refrigerant charging vent.
Leakage detection
1. With leakage detector:
Check if there is leakage with leakage detector.
2. With soap water:
If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more
than 3min. If there are air bubbles coming out of this position, there's a leakage.
15
English
Use vacuum pump
Check after installation
● Check the following requirements after finishing installation.
Items to be checked
Possible malfunction
Has the unit been installed firmly?
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage
test?
It may cause insufficient cooling
(heating) capacity.
Is heat insulation of pipeline sufficient?
It may cause condensation and water
dripping.
Is water drained well?
It may cause condensation and water
dripping.
English
Is the voltage of power supply according
It may cause malfunction or damage the
to the voltage marked on the
parts.
nameplate?
Is electric wiring and pipeline installed
correctly?
It may cause malfunction or damage the
parts.
Is the unit grounded securely?
It may cause electric leakage.
Does the power cord follow the
specification?
It may cause malfunction or damage the
parts.
Is there any obstruction in the air inlet
and outlet?
It may cause insufficient cooling
(heating) capacity.
The dust and sundries caused during
installation are removed?
It may cause malfunction or damage the
parts.
The gas valve and liquid valve of
connection pipe are open completely?
It may cause insufficient cooling
(heating) capacity.
Test operation
1. Preparation of test operation
● The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
16
Configuration of connection pipe
1. Min. length of connection pipe is 3m.
2. Max. length of connection pipe and max. height difference.
25 class
9000Btu/h
(2637W)
35 class
12000Btu/h
(3516W)
50 class
18000Btu/h
(5274W)
60 class
24000Btu/h
(7032W)
Max length
of connection pipe
Max height
difference
15
10
15
10
25
10
25
10
English
Cooling
capacity
3. The additional refrigerant oil and refrigerant charging required after lengthening
connection pipe
● The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):
Additional refrigerant charging amount = extra length of liquid pipe × additional
refrigerant charging amount per meter
● When the length of connection pipe is above 10m, add refrigerant according to
the extra length of liquid pipe. The additional refrigerant charging amount per
meter is different according to the diameter of liquid pipe. See the following
sheet.
● Additional refrigerant charging amount for R22, R407C, R410A and R134a
Diameter of connection pipe
Liquid pipe(mm) Gas pipe(mm)
Ø6
Ø9.52 or Ø12
Ø6 or Ø9.52
Ø16 or Ø19
Ø12
Ø19 or Ø22.2
Outdoor unit throttle
Cooling only(g/m) Cooling and heating(g/m)
15
20
15
50
30
120
17
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
A: Cut the pipe
E: Expand the port
● Confirm the pipe length according to
● Expand the port with expander.
the distance of indoor unit and
hard
outdoor unit.
mold
● Cut the required pipe with pipe cutter.
expander
pipe
pipe
pipe cutter
uneven
burr
English
leaning
Note:
● "A" is different according to the
diameter, please refer to the sheet
below:
A(mm)
Max
Min
1.3
0.7
1.6
1.0
1.8
1.0
2.4
2.2
Outer diameter
(mm)
B: Remove the burrs
● Remove the burrs with shaper and
prevent the burrs from getting into
the pipe.
Ø6 - 6.35(1/4")
Ø9.52(3/8")
Ø12 - 12.7(1/2")
Ø15.8 - 16(5/8")
pipe
shaper
downwards
F: Inspection
● Check the quality of expanding port.
If there is any blemish, expand the
port again according to the steps
above.
smooth surface
C: Put on suitable insulating pipe
D: Put on the union nut
● Remove the union nut on the indoor
connection pipe and outdoor valve;
install the union nut on the pipe.
union pipe
improper expanding
leaning
the length is equal
pipe
18
damaged
surface
crack
uneven
thickness
Buttons on remote controller
ON/OFF button
MODE button
+/- button
FAN button
SWING button
SAVE button
X-FAN button
TIMER button
SLEEP button
LIGHT button
Introduction to icons on display screen
Child Lock
Dry mode
Auto mode
Set temp
Cool mode
Heat mode
Fan mode
X-fan
Up & down swing
Sleep mode
Set time
Timer ON/Timer OFF
19
Fan speed
English
TURBO button
Introduction to buttons on remote controller
Note:
● After putting through power, the air conditioner will give out a sound and operation
indicator " " is ON (red indicator). You can operate the air conditioner through
the remote controller.
● At ON status, after pressing a button on the remote controller, the signal icon " "
on the remote controller will flash once. The air conditioner will give out a sound,
which indicates the signal has been sent to the air conditioner.
● At OFF status, display screen on the remote controller displays the set
temperature. At ON status, display screen on the remote controller displays the
corresponding startup function icon.
English
1
ON/OFF button
Press this button to turn on or turn off the air conditioner. After turning on the unit,
the operation indicator " " on the indoor unit is ON (blue indicator. Color may be
different for different models) and indoor unit gives out a sound.
2
MODE button
Press this button to select your required operation mode.
● After selecting auto mode, the air conditioner will operate automatically according
to ambient temperature. The set temperature can’t be adjusted and also can’t be
displayed. Press the "FAN" button to adjust fan speed. Press the "SWING" button
to adjust swing angle.
● After selecting the cool mode, the air conditioner operates under cool mode. The
cool indicator " " on the indoor unit is ON. You can press the "+" or "-" buttons
to adjust the set temperature. Press the "FAN" button to adjust fan speed. Press
the "SWING" button to adjust the swing angle.
● After selecting the dry mode, the air conditioner operates under dry mode at low
speed. The dry indicator " " on the indoor unit is ON. Under dry mode, fan speed
can’t be adjusted. Press the "SWING" to adjust the swing angle.
● After selecting the fan mode, the air conditioner operates only under fan mode,
the other mode indicators on indoor unit are OFF. Press the "FAN" button to
adjust fan speed. Press the "SWING" button to adjust the swing angle.
● After selecting the heat mode, the air conditioner operates under heat mode. The
heat indicator " " on the indoor unit is ON. You can press the "+" or "-" buttons
to adjust the set temperature. Press the "FAN" button to adjust fan speed. Press
the "SWING" button to adjust the swing angle. (Cooling only unit can’t receive the
signal for heating mode.)
20
Introduction to buttons on remote controller
Note:
The air conditioner is designed to start discharging air only after it has reached
a certain temperature in heating mode (usually 1-5min depending on indoor ambient
temperature). Temperature setting range on remote controller: 16°C-30°C. Fan
speed setting range: auto, low speed, medium speed and high speed.
3
"+" or "-" button
4
FAN button
Press this button to select the fan speed in sequence: auto (AUTO), low speed (
medium speed ( ), high speed (
).
),
Note:
● Under auto mode, the air conditioner will select proper fan speed according to
ex-factory setting automatically.
● Low speed under dry mode.
5
SWING button
● Press this button to select up&down swing. In auto swing mode, the horizontal
louver of the air conditioner will swing up&down automatically at maximum angle.
This mode will be indicated on the display of the remote controller by an icon.
● Pressing "SWING" on the remote controller again will cause the horizontal louver
of the air conditioner to stop moving and stay fixed at that angle. In this mode,
the icon on the remote controller will disappear.
21
English
● Each pressing of the "+" or "-" button can increase or decrease the set
temperature by 1°C. Hold the "+" or "-" button for at least 2s and the set
temperature on the remote controller will change quickly. After reaching to
the required time, release the button.
● Under TIMER ON, TIMER OFF or Clock setting, you can press the "+"or "-" button
to adjust time. (Refer to TIMER button for details)
Introduction to buttons on remote controller
6
SAVE button
SAVE function:
Under cool mode, press the SAVE button and the unit will operate under SAVE
mode. The remote controller will display "SE" and the air conditioner will operate at
auto speed. The set temperature can’t be adjusted. Press the SAVE button again to
exit the SAVE mode. The air conditioner will return to the original set speed and set
temperature.
● This function is only applicable to some models.
7
X-FAN button
English
After pressing this button under cooling or dry mode, the remote controller displays
the "X-FAN" icon and the X-FAN function is started up. Press this button again to
cancel the X-FAN function. The "X-FAN" icon will disappear.
Note:
● After starting up the X-FAN function, when turning off the unit, the indoor fan will
continue to operate for a while at low speed to dry the residual water inside the
indoor unit.
● When the unit operates under the X-FAN mode, press "X-FAN" button to turn off
the X-FAN function. The indoor fan will stop operating immediately.
8
TIMER button
● At ON status, press this button once to set TIMER OFF. The character of HOUR
and OFF will flash. Press the "+" or "-" button within 5s to adjust the time of TIMER
ON. Each time the "+" or "-" button is pressed, time will increase or decrease by
half an hour. When holding the "+" or "-" button for at least 2s, the time will change
quickly until the required time is reached. After that, press the "TIMER" button
to confirm it. The character of HOUR and OFF won’t flash again. Cancel
TIMER OFF: Press the "TIMER" button again under TIMER OFF status.
● At OFF status, press this button once to set TIMER ON. Please refer to
TIMER OFF for detailed operation.
Cancel TIMER ON: Press the "TIMER" button again under TIMER ON status.
Note:
● Time setting range: 0.5-24 hours.
● Time interval between two operations can’t exceed 5s, otherwise the remote
controller will exit the setting status automatically.
● The TIMER OFF function is resetted when the CHILD LOCK function is unlocked.
22
Introduction to buttons on remote controller
9
TURBO button
When pressing this button under cooling or heating mode, the air conditioner will
enter into quick cooling or quick heating mode. The "TURBO" icon is displayed on
the remote controller. Press this button again to exit turbo function and the "TURBO"
icon will disappear on the remote controller.
10
SLEEP button
Press this button under cooling, heating or drying mode to start up sleep function.
The " " icon will be displayed on the remote controller. Press this button again to
cancel the sleep function. The " " icon on the remote controller will be displayed.
LIGHT button
Press this button to turn off the light on the display of the indoor unit. Press this
button again to turn on the light on the display of the indoor unit.
Introduction to functions of combination buttons
Child lock function
Pressing the "+" and "-" buttons simultaneously can turn the child lock function on or
off. When the child lock function is started up, the " " icon will be displayed on the
remote controller. If any buttons are then pressed on the remote controller, the " "
icon will flash three times, while the remote controller won’t send any signal.
Switchover function for temperature display
After turning off the unit with the remote controller, press the "-" button and the
"MODE" button simultaneously to switch between °C and °F.
23
English
11
Operation guide
1. After putting through the power, press "
" button on remote controller to turn
on the air conditioner.
2. Press "
" button to select your required mode: AUTO, COOL, DRY, FAN,
HEAT.
3. Press "+" or "-" button to set your required temperature. (Temperature can’t be
adjusted under auto mode).
4. Press "
" button to set your required fan speed: auto, low, medium and
high speed.
5. Press the "
" button to select fan blowing angle.
English
Replacement of batteries in remote controller
1. Press the back side of remote controller marked
with " ", as shown in the fig, and then push out
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and
make sure the position of "+" polar and "-" polar
are correct.
3. Reinstall the cover of battery box.
signal sender
battery
reinstall
remove
Cover of battery box
Note:
● During operation, point the remote control signal sender at the receiving
window on indoor unit.
● The distance between signal sender and receiving window should be no more
than 8m, and there should be no obstacles between them.
● Signal may be interfered easily in the room where there is fluorescent lamp
or wireless telephone; remote controller should be close to indoor unit during
operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the
batteries.
● If the display on remote controller is fuzzy or there’s no display, please replace
batteries.
24
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn on or
turn off the air conditioner. The operation in details are as below: As shown in the
fig. Open panel, press aux. button to turn on or off the air conditioner. When the
air conditioner is turned on, it will operate under auto mode.
panel
Cleaning and Maintenance
Note:
■ Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditioner.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth or
wet cloth to wipe it.
Note:
● Do not remove the panel when cleaning it.
25
English
aux. button
Cleaning and Maintenance
Clean filter
English
1
2
Open panel
Clean filter
3
Pull out the panel to a certain
angle as shown in the fig.
● Use dust catcher or water to clean
the filter
● When the filter is very dirty, use
the water (below 45°C) to clean it,
and then put it in a shady and cool
place to dry.
Remove filter
Remove the filter as indicated
in the fig.
4
Install filter
Install the filter and then close the
panel cover tightly.
Note:
■ The filter should be cleaned every three months. If there is much dust in the
operation environment, cleaning frequency can be increased.
■ After removing the filter, do not touch fins to avoid injury.
■ Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard.
26
Cleaning and Maintenance
Checking before active season
1. Check whether air inlets and air outlets are blocked.
2. Check whether earth leakage circuit breaker, plug and socket are in good
condition.
3. Check whether filter is clean.
4. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
5. Check whether drainage pipe is damaged.
1. Disconnect power supply.
2. Clean filter and indoor unit’s panel.
3. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
Notice for recovery
1. Many packing materials are recyclable materials.
Please dispose of them in appropriate recycling unit.
2. If you want to dispose of the air conditioner, please contact local dealer
or consultant service center for the correct disposal method.
27
English
Checking after active season
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
can’t be eliminated, please contact local dealer or qualified professionals.
English
Phenomenon
Indoor unit
can’t receive
remote
controller’s
signal or
remote
controller
doesn’t seem
to work.
Check items
Solution
● Whether it's interfered
● Switch the power off. After
severely (such as static
about 3min, switch the unit
electricity, stable voltage)?
on again.
● Whether remote controller is
within the signal receiving
● Signal receiving range is 8m.
range?
● Whether there are obstacles? ● Remove obstacles.
● Select proper angle and point
● Whether remote controller is
the remote controller at the
pointing at the receiving
receiving window on indoor
window?
unit.
● Is sensitivity of remote
● Check the batteries. If the
controller low; fuzzy display
power of batteries is too low,
and no display?
please replace them.
● Check whether remote
● No display when operating
controller appears to be
remote controller?
damaged. If yes, replace it.
● Take the remote controller
close to indoor unit.
● Fluorescent lamp in room?
● Turn off the fluoresent lamp
and then try it again.
● Air inlet or air outlet of indoor
● Eliminate obstacles.
unit is blocked?
● Under heating mode, indoor ● After reaching to set
temperature is reached to set
temperature, indoor unit will
No air emitted
temperature?
stop blowing out air.
from indoor
● In order to prevent blowing
unit
out cold air, indoor unit will be
● Heating mode is turned on
started after delaying for
just now?
several minutes, which is
a normal phenomenon.
28
Malfunction analysis
Phenomenon
Check items
Solution
●
●
Air conditioner
can’t operate ●
●
● Wait until power recovery.
● Ask professional to replace
Earth leakage circuit breaker
earth leakage circuit breaker
trips off or fuse is burnt out?
or fuse.
Wiring has malfunction?
● Ask professional to replace it.
Unit has restarted
● Wait for 3min, and then turn
immediately after stopping
on the unit again.
operation?
Whether the function setting
for remote controller is
● Reset the function.
correct?
Mist is emitted
● Indoor temperature and
from indoor
humidity is high?
unit’s air outlet
Set
temperature
can’t be
adjusted
Cooling
(heating)
effect is
not good.
● Unit is operating under auto
or save mode?
● Because indoor air is cooled
rapidly. After a while, indoor
temperature and humidity will
decrease and mist will
disappear.
● Temperature can’t be
adjusted under auto and save
modes. Please switch the
operation mode if you need to
adjust temperature.
● Your required temperature
● Set temperature range:
exceeds the set temperature
16°C~30°C .
range?
● Voltage is too low?
● Filter is dirty?
● Set temperature is in proper
range?
● Door and window are open?
29
● Wait until the voltage
resumes to normal.
● Clean the filter.
● Adjust temperature to proper
range.
● Close door and window.
English
● Power failure?
Malfunction analysis
Phenomenon
Odours are
emitted
Check items
Solution
● Whether there’s odour
● Eliminate the odour source.
source, such as furniture and
● Clean the filter.
cigarette, etc.
Air conditioner ● Whether there’s interference, ● Disconnect power, put back
operates
such as thunder, wireless
power, and then turn on the
suddenly
devices, etc.
unit again.
English
Outdoor unit
has vapor
● Heating mode is turned on?
"Water
● Air conditioner is turned on or
flowing" noise
turned off just now?
Cracking
noise
● During defrosting under
heating mode, it may
generate vapor, which is
a normal phenomenon.
● The noise is the sound of
refrigerant flowing inside the
unit, which is a normal
phenomenon.
● This is the sound of friction
caused by expansion and/or
● Air conditioner is turned on or
contraction of panel or other
turned off just now?
parts due to the change of
temperature.
30
Malfunction analysis
Malfunction
● When the air conditioner status is abnormal, please refer to the list below for
identification of error code.
The indicator diagram on
the left is only for reference.
Indoor
display Please refer to the actual
product for the actual indicator
and position.
The error codes listed below are only examples of error codes. Please refer to error
code list in service manual for more information.
Troubleshooting
Means defrosting status. It’s the normal phenomenon.
Power indicator blinks
11 times every 3s
It can be eliminated after restarting the unit. If not, please
contact qualified professionals for service.
It can be eliminated after restarting the unit. If not, please
contact qualified professionals for service.
It can be eliminated after restarting the unit. If not, please
contact qualified professionals for service.
It can be eliminated after restarting the unit. If not, please
contact qualified professionals for service.
Power indicator blinks
15 times every 3s
Please contact qualified professionals for service.
Cooling indicator blinks
1 time every 3s
Please contact qualified professionals for service.
Cooling indicator blinks
Please contact qualified professionals for service.
Power indicator blinks
5 times every 3s
Power indicator blinks
8 times every 3s
Power indicator blinks
17 times every 3s
Warning
■ When the following phenomenon occurs, please turn off the air conditioner and
disconnect power immediately, and then contact the dealer or qualified
professionals for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Earth leakage circuit breaker trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
■ Do not repair or refit the air conditioner by yourself.
■ If the air conditioner operates under abnormal conditions, it may cause
malfunction, electric shock or fire hazard.
31
English
Error code
Heating indicator
ON 10s OFF 0.5s
Wiring
● Do not turn ON the safety breaker until all work is completed.
1) For both outdoor and indoor units, strip the insulation from the
wire (40mm).
2) Connect the connection wires between the indoor and outdoor units
so that the terminal numbers match. Tighten the terminal screws
securely. We recommend a flathead screw driver be used to tighten
the screws.
3) For connecting outdoor unit to indoor unit use standardized supply
cable H05RN.
Firmly fix the wires with
the terminal screws.
Indoor unit
When wire length exceeds 10m,
use 2.0mm diameter wires.
1 23
English
1
Safety
breaker
Outdoor 2
3
unit
Firmly fix the wires with
the terminal screws.
Earth leakage
circuit breaker
H05RN
Earth
32
Power supply
50Hz 220-240V
Wiring
Indoor Unit
Outdoor Unit
AP..............................................Printed Circuit Board
AP ............................................. Printed Circuit Board
TEM.Sensor...............................Temperature Sensor
TEM.Sensor .............................. Temperature Sensor
RT..............................................Thermistor
RT ............................................. Thermistor
W ...............................................Wire
OVC-COMP .............................. Compressor Overload Protector
DISP ..........................................Display
EKV........................................... Electronic expansion valve coil
CN .............................................Connector
CN............................................. Connector
AC-L ..........................................Alternating current-live line
AC-L.......................................... Alternating current-live line
K ................................................Relay
AC-N ......................................... Alternating current-neutral line
PG .............................................Pulse Generator
YV ............................................. Way valve
PGF ...........................................Pulse Generator Feedback
OFAN ........................................ Outdoor Fan
M................................................Motor
DC............................................. Direct Current
L-OUT........................................Line-out
WH ............................................ White
COM-OUT .................................Communication-Out
COM-OUT................................. Communication-Out
N ................................................Naught
N ............................................... Naught
XT ..............................................Terminal Block
XT ............................................. Terminal Block
PE..............................................Protective earth
PE ............................................. Protective earth
BN..............................................Brown
BN ............................................. Brown
BU..............................................Blue
BU ............................................. Blue
BK..............................................Black
BK ............................................. Black
YEGN ........................................YellowGreen
YEGN........................................ YellowGreen
RD .............................................Red
RD............................................. Red
YE..............................................Yellow
YE ............................................. Yellow
VT ..............................................Violet
VT ............................................. Violet
L.................................................Live line
L ................................................ Live line
Jump Cap ..................................The cap of the jumper
4V ............................................. Four-way valve
(U.D) ..........................................Up, Down
COM ......................................... Communication
GN .............................................Green
COMP ....................................... Compressor
SAT ........................................... Overload protection service
OG ............................................ Orange
FA ............................................. Electric expansion interface
INDC ......................................... Port of reactor
33
English
Wiring Diagram
66129915424
Copyright 2013 Daikin