E-Catalog - CFL and LED Tester|Photometer|Spectrophotometer

E-Catalog - CFL and LED Tester|Photometer|Spectrophotometer
2016 Catalog
All Rights Reserved
Lisun Group (Hong Kong) Limited
Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon, Hong Kong
Tel: 00852-68852050 Fax: 00852-30785638
Email: SalesHK@Lisungroup.com
Lisun Electronics (Shanghai) Co., Ltd
Add: 113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading District, Shanghai, China
Tel: +86(21)51083341 Fax: +86(21)51083342
Email: SalesSH@Lisungroup.com
Lisun Sales Rep & Show Room (India)
Add: Plot No 362 Industrial Area, Phase II, PANCHKULA, HARYANA, PIN 134112, India
Tel: 0172-5066372
Mobile: 9316473033
Email: Sales@Lisungroup.com
Lisun Sales Rep & Show Room (Korea)
Add: 2F, 20, Guui-ro, Gwangjin-gu, Seoul, Korea
Tel: +82-2-6012-9113 Mobile: +82-10-8542-0447
Email: Sales@Lisungroup.com
Lisun Sales Rep (Russia)
Add: Russia, Saint-Petersburg 22 line VO, 3
Tel: +7(812) 320-25-88
Email: SalesRu@Lisungroup.com
APP Download
APP Download
Lisun Electronics lnc.
Http://www.Lisungroup.com
LISUN GROUP
Company Profile
Lisun Electronics Inc was found by Lisun Group in 2003. We have sales & show room in
Shanghai, Russia, USA, India and Korea. In 2012, we built a high level products show room &
lab center in Shanghai. Lisun Group has set up a new manufactory in China to research and
develop the world high-technology CFL & LED Test Instruments. Its quality system has been
strictly certified by ISO9001:2008. The Lisun Group products have been authenticated by the
third party lab and were awarded by CE certificate. As a CIE Supportive Membership, all of the
test instruments produced by Lisun Group were designed according to CIE Standards.
Our main products are Goniophotometer, Spectrophotometer, Integrating Sphere,
Photometer and Colorimeter, LED Test Instruments, CFL Test Instruments, EMC Testing,
Electronic Ballast Tester, Equipments For Testing Electronic Components, Electrical Safety
Testing, Environmental Testing, AC and DC Power Supply and etc.
Lisun Group's products have been sold to more than 80 countries and regions in Europe,
America, Australia, Africa and Asia. Its quality was well accepted by many of world-famous
companies such as TUV, SGS, UL, GE, Philips, Sharp, OSRAM, SONY and so on. Lisun Group
wins thousands of customers' trust with motto "Right Product, Right Price and Right Service".
We will continue presenting more and more high quality products to our customers in future.
Right Product
Right Price
Right Service
Our Customers
LSG-1600B Goniophotometer in Malaysia
3m Integrating Sphere in USA
EMI and EMC Install & Training in India
LSG-1800B Goniophotometer in Germany
Environmental and Safety Test Chambers in Algeria
LM-79 Goniophotometer in Mexico
Lisun Electronics lnc.
Http://www.Lisungroup.com
LISUN GROUP
CONTENTS
Part 1 Goniophotometer
LM-79 Goniophotometer System
LSG-3000, LSG-2000
1
Goniophotometer for Automotive and Signal Lamps
LSG-1950, LSG-1950S
3
High Precision Rotation Luminaire Goniophotometer
LSG-1800B, LSG-1700B
4
High Precision Goniospectroradiometer
LSG-1800BCCD, LSG-1700BCCD
5
Rotation Luminaire Goniophotometer
LSG-1800, LSG-1700, LSG-1600
6
Compact Goniophotometer
LSG-1200A
7
High Precision CCD Spectroradiometer
LMS-9000B, LMS-9000A
8
Scientific Grade CCD Spectroradiometer
LMS-8500
9
CCD Spectroradiometer
LMS-8000A, LMS-8000
10
Quick-Scan Spectrophotometer Colorimeter
LMS-5000
10
Fiber Optic Spectrometer
LMS-1000
11
Part 3 Integrating Sphere
Integrating Sphere with Testing Holder Base
Integrating Sphere with Side Assistant Opening
IS-*MA
12
IS-*MA**P, IS-*MA**C
13
Constant Temperature Integrating sphere
IS-*MT
14
Integrating Sphere Spectroradiomter System for LED
LPCE-2
15
Lamp Start, Run-up time and Flicker Test
LSRF-1
16
Fast Photo-Electric Tester
LS616S
16
LED Lumen Maintenance and Aging Life Test System
LEDLM-80PL
17
LED Power Driver Tester
WT2080
18
LED Power Driver on line Tester
WT2080-OK
19
LED Driver Online Tester
LSLED-12
19
LED Power Driver Automatic Test System
ATE-2
20
Spectrophotometer & Integrating sphere Test System
LPCE-1
21
High Frequency Fluorescent Lamp Test System
HFP-800, RB-3, LPS-3
22
Adjustable Reference Ballast
DYJ-50HZ, DYJ-60HZ, DYJ-HID
23
Adjustable High Frequency Reference Ballast
HCS-105A
23
Multiplex Temperature Tester
TMP-8, TMP-16
23
Multiway Life Tester
CH316
24
Digital Torsion Meter
CH338
24
GNG-E27
24
Luminance Colorimeter
XYL-VI
25
Photometer
PH2000
25
Pocket Chroma Meter
CHROMA-2
26
Pocket Brightness Meter
PHOTO-100L
26
Pocket Illumiance Meter
PHOTO-100
26
Part 2 Spectroradiometer
Part 4 LED Test Instruments
Part 5 CFL Testing Instrument
“Go” and “Not Go” Gauge
Part 6 Colorimeter and Photometer
Lisun Electronics lnc.
Http://www.Lisungroup.com
LISUN GROUP
Part 7 EMC and EMI Test System
EMI Test System
Magnetic
Shielding Cabinet for EMI Testing
Electrostatic
Discharge Simulator
EFT Immunity Measurement
Surge
Generator
Impulse Withstand Voltage Tester
Voltage Dips and Interruptions Generator
KH3961, KH3962
27
SDR-2000B, SDR-800S
27
ESD61000-2
28
EFT61000-4
28
SG61000-5
29
SUG255LX, SUG255PX
29
CSS61000-11
30
RWG61000-12
31
Electronic Ballast Tester
WT5000
32
Electronic Ballast Analyzer
WT3000
33
Electronic Ballast Automatic Test Equipment
ATE-1
33
HID Ballast Tester
WT2000-HID
33
ZRS-3HS, ZRS-3H
34
ZY-3S, ZY-3
34
HVR-LSS, HVR-LS
35
RSY-LT
35
TTC-1
36
TMP-L
36
LS9934, LS9935
37
Ring Wave Generator
Part 8 Electronic Ballast Tester
Part 9 Electrical Safety Test
Glow-wire Test Apparatus
Needle Flame Test
Horizontal Vertical Flame Tester
Hot Wire Ignition tester
Tracking
Test Chamber
Temperature Meter for Lamp Caps & Luminaires Test
Automatic Safety Test System
Programmable Withstanding Voltage & Insulation Test
LS9922I
37
AC/DC Withstand Voltage Test
WB2671A
38
Insulation Resistance Tester
WB2681A
38
Digital Oscilloscope
JC2202TA
38
High and Low Temperature & Humidity Chamber
GDJS-015A, GDJW-010A
39
Waterproof Testing Machine
JL-X
40
High Temperature & Pressure Jet Waterproof Test
JL-9K1L
41
Aging and Life Test Rack for CFL and LED
SY2036
41
Dustproof Testing Machine
SC-015
42
IK Level Tester
IK01-06, IK07-10
42
Salt Spray Test Machine
YWX/Q-010
43
Electrodynamic Vibration Generator System
LVD-100KG
43
Digital CC and CV DC Power Supply
DC3005
44
AC power Source
LSP-500VA, LSP-500VAR
44
PWM Type AC Power Supply
LSP-3KVA, LSP-5KVA
45
Digital Power Meter
LS2008R, LS2010, LS2012, LS2050
45
Magnetic Material Analyzer
UI9730
46
DC Bias Current Source
FD1772B
46
LCR Digital Bridge
FD2810B
46
Electrolytic Capacitor Meter
HF2686C
46
Part 10 Environmental Test Chamber
Part 11 AC and DC Power Supply
Part 12 Electronic Component Test
Part 1 Goniophotometer
LISUN GROUP
LM-79 Goniophotometer Systems (LSG-3000, LSG-2000)
According to LM-79 clause 9.3.1, only two kinds of type C goniophotometer can be accepted: LSG-3000
Moving Detector Goniophotometer and LSG-2000 Goniophotometer with Moving Mirror. The LSG-3000
and LSG-2000 are automatic light distribution intensity 3D curve testing system. The measuring distance
is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor
and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaries.
Measurement:
Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency,
Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves, Glare, Maximum Ratio
of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela
Diagrams, Efficient Luminescence Angle and so on.
Specification:
• The tested luminaire rotates around the mirror with an angle of (γ) ±180° (or 0~360°)
• The accuracy of angle: 0.0016° Resolution of angle: 0.01°
• Accuracy of photometry: Constant temperature photo detector. CIE class A (Standard Class) or can
be optional Class L
• The test result can be exported as CIE, IES, LDT and other format files. This kind of format files can
be transferred by other illumination and luminaire design software such as DiaLux
• The rotation motor is from Japan MITSUBISHI MOTORS and it uses Germanic Angle decode system; it
will help rotation smoothly and with high accuracy. It is very stable when start and stop.
• LSG-2000 and LSG-3000 completely meet the LM-80, LM-79, LM-75, GB, EN and CIE121-1996.
• RS-232C standard interface connect with PC, English version software can run in Win7 or Win8
• It can be option work with a USB CCD Spectroradiometer to test spatial CCT Distribution and other
Spectral color parameters. We call this system as Goniospectroradiometer
Model Number
LSG-3000/LSG-2000
(Standard Size)
LSG-3000B/LSG-2000B
(Big Size)
LSG-3000S/LSG-2000S
(Small Size)
Measure Non-Flood Lamp Φ1600*800mm, 50kg
Φ1400*500mm, 40kg
Φ1000*460mm, 30kg
Measure Flood Lamp
600*600mm, 50kg
600*600mm, 40kg
400*400mm, 30kg
Measure Power(W)
600V/10A, AC/DC
600V/10A, AC/DC
600V/10A, AC/DC
Test Report:
1
Part 1 Goniophotometer
LISUN GROUP
Test Principle:
LSG-3000 Moving Detector Goniophotometer
LSG-2000 Goniophotometer with Rotating Mirror
2
Part 1 Goniophotometer
LISUN GROUP
Goniophotometer for Automotive and Signal Lamps (LSG-1950, LSG-1950S)
Measurement:
LSG-1950/LSG-1950S is the CIE A-α Goniophotometer which used to to test automotive lighting
industry, traffic signal, bus, train, ship, and aircraft lighting. The photometer head keeps static and
face to the test sample while the test sample rotates around both horizontal axis and vertical axis,
so the luminous intensity and illuminance of the tested lamp or luminaires can be tested.
LSG-1950 Standard Version
LSG-1950S Economic Version
Specifications
•
•
•
•
•
•
It is designed according to EN, IEC, GB, ECE, SAE and FMVSS108
A axis rotating -180~180° and α axis rotating, the accuracy of angle: 0.001° Resolution of angle: 0.01°
Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity 1.0cd~107cd(detector)
Accuracy of photometry: CIE Class A or Class L (option)
Testing Accuracy: 2% (Under Standard lamp); Stray Light: less than 0.1%
Can test max lamp to 35kg and English version software can run in WinXP, Win7 and Win8
3
Part 1 Goniophotometer
LISUN GROUP
High Precision Rotation Luminaire Goniophotometer (LSG-1800X, LSG-1800B, LSG-1700B)
The Rotation Luminaire Goniophotometer is an automatic goniophotometric measurement system for
measuring photometric parameters of luminaires, such as LED road lighting fixture, room lighting fixture
and projecting lighting fixture. The measured data meets IES standard format and can be applied in
lighting design by lighting design software. The measurement system fully satisfies the requirements
of lighting design work.
Measurement:
Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency,
Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio
of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela
Diagrams, Efficient Luminescence Angle, EEI, UGR and so on.
LSG-1800B Goniophotometer with Constant Temperature Detector
Specification:
• Meets the requirements of CIE, IEC, IES LM-79 & GB standards
• Reaching many measurement ways such as B-β and C-γ
• The tested luminaries rotates around an angle of (γ)±180°(or 0~360°) and the tested luminaries
rotates around itself with an angle of (C)±180° (or 0~360°)
7
• Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity 1.0cd~10 cd(detector)
• The accuracy of angle: 0.0017° (LSG-1800X/LSG-1800B) and 0.01° (LSG-1700B)
• Accuracy of photometry: CIE Class A (Class L is optional)
• Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1%
• English version software can run in WinXP, Win7 or Win8
• This system can export data files as following formats: ies, ldt, cie, cib, tm4, cen, excel and so on.
This kind of format files can be transferred by luminaire design software such as DiaLux.
Max Size for the Testing Lamp (mm)
The max size for the Testing Lamp
Max Weight
Non-Flood Lamp (Diameter*Depth) Flood Lamp (L*W)
LSG-1800X
Design according to customer’s lamp size
50kg
LSG-1800B
Φ1600*550
700*600
50kg
LSG-1700B
Φ1600*500
700*600
30kg
4
Part 1 Goniophotometer
LISUN GROUP
High Precision Goniospectroradiometer (LSG-1800XCCD, LSG-1800BCCD, LSG-1700BCCD)
LSG-1800XCCD/LSG-1800BCCD/LSG-1700BCCD Goniospectroradiometer can do the spatial CCT test
when do the intensity distribution test. It is for industrial laboratory measurements the photometric data
of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
LMS-9000B CCD Spectroradiometer
LSG-1800XCCD/LSG-1800BCCD/LSG-1700BCCD Goniospectroradiometer
Specification:
• Meets the requirements of CIE, IEC, IES LM-79 & GB standards
• Reaching many measurement ways such as B-β and C-γ
• The tested luminaries rotates around an angle of (γ)±180°(or 0~360°) and the tested luminaries rotates
around itself with an angle of (C)±180°(or 0~360°)
7
• Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity 1.0cd~10 cd(detector)
• The accuracy of angle: 0.0017° (LSG-1800XCCD and LSG-1800BCCD) and 0.01° (LSG-1700BCCD)
• Work with High Accuracy and quick CCD Spectraidomeeter to measure spatial color parameters.
• Accuracy of chromaticity coordinate: ±0.0015 or ±0.0005(under standard A lamp)
• Spectral Range Wavelength: 380nm~780nm; Accuracy of wavelength: ±0.5nm
• Accuracy of photometry: CIE Class A (Class L is for option)
• Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1%
• English version software can run in WinXP, Win7 or Win8
Test Report:
P.S. The test files can be export as following format: ies, ldt, cib, tm4, cie, cen, csv
5
Part 1 Goniophotometer
LISUN GROUP
Rotation Luminaire Goniophotometer (LSG-1800, LSG-1700, LSG-1600)
The Rotation Luminaire Goniophotometer is an automatic goniophotometric measurement system for
measuring photometric parameters of luminaires, such as LED road lighting fixture, room lighting fixture
and projecting lighting fixture. The measured data meets IES standard format and can be applied in
lighting design by lighting design software. The measurement system fully satisfies the requirements of
lighting design work.
Measurement:
Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency,
Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio of
Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela
Diagrams, Efficient Luminescence Angle, EEI, UGR and so on.
The max size for the Testing Lamp
B-Beta Test with Two Pillars
Max
Weight
Φ1600*550(Dia*Depth)
700*600(L*W)
50kg
LSG-1700
Φ1400*500(Dia*Depth)
N/A
30kg
LSG-1600
Φ1200*350(Dia*Depth)
N/A
20kg
Max Size for the Testing Lamp (mm)
C-Gamma Test with one Pillar
LSG-1800
Specification:
•
•
•
•
Meets the requirements of CIE, IEC, IES LM-79 & GB standards
LSG-1800 can do both B-Beta & C-Gamma and LSG-1700/LSG-1600 only can do C-Gamma test
The accuracy of angle: 0.01° (LSG-1800); 0.1° (LSG-1700 and LSG-1600)
The tested luminaries rotates around an angle of (γ)±180°(or 0-360°) and the tested luminaries rotates
around itself with an angle of (C)±180°(or 0-360°)
7
• Luminosity Testing Range: Illuminance 0.001lx~10,000lx; Light Intensity 1.0cd~10 cd(detector)
• English version software can run in WinXP, Win7 or Win 8
Goniospectroradiometer (LSG-1800CCD, LSG-1700CCD, LSG-1600CCD)
Goniophotometer+Spectroradiometer= Goniospectroradiometer which can do the spatial CCT test when
do the intensity distribution test
LMS-8500 CCD Spectroradiometer
Specification:
•
•
•
•
•
•
•
The accuracy of angle: 0.01° (LSG-1800CCD); 0.1° (LSG-1700CCD and LSG-1600CCD)
Test CCT and Spectrum Distribution Test for the lamp, the data can be export be excel
Spectral Range Wavelength: 380~780nm; Wavelength Accuracy: ±0.2nm
Accuracy of Chromaticity Coordinates x, y: ±0.0015
Correlated Color Temperature Range: 1,000~100,000K, Resolution: 1K
Accuracy of photometry: Class 1
Testing Accuracy: 3%(Under Standard lamp); Stray Light: less than 0.2%
6
Part 1 Goniophotometer
LISUN GROUP
Compact Goniophotometer (LSG-1200A)
The compact goniophotometer of LSG-1200A is applied to measure the luminous intensity distribution
curve, intensity data, spread angle and other parameters for chip LED, LED module, LED sportlight
and all other light which beam angle is no more than 180 degree.
Option Function: The LSG-1200A can work with a Digital Power Meter (LS2012 DC & AC Power Meter
or LS2010 Harmonic Analyzer), LSP Series AC Power Source or DC Series DC Power Source.
Specification:
Meets the requirements of IEC, CIE and LM-79 standards
Measures beam angle automatically: staple half intensity angle as well as 1/4 intensity angle, 3/4
intensity angle and 1/10 intensity angle which meets the special requirements.
Measured data is matched with international standard form (IES) and can be applied for lighting design
by other lighting design software such as DiaLux
LSG-1200A has included a dark chamber, measures the maximum size of lamps: 180mm
Test range of luminosity: 0.1~30,000lx. Test accuracy of detector: Class 1
The distance between the tested lamp and detector is 316mm/1000mm
Angle interval: Horizontal angle: 1°/5°/10°/15°/22.5°/30°/45°/90°, Vertical angle: 0.5°/2°/1.5°
The LSG-1200A horizontal automatic rotating on 0°~360° and Vertical automatic rotating on -90°~+90°
Test accuracy of angle: ±0.2°.
Illuminance
Photometric
7
Isocandela
Part 2 Spectroradiometer
LISUN GROUP
High Precision CCD Spectroradiometer (LMS-9000B, LMS-9000A)
LMS-9000B/LMS-9000A is according to LM-79 clause 9.1. It is designed to have a capability of producing any
visible spectral distribution, mimicking various light sources in the visible region by feedback control of the
radiant power emitted by individual LEDs. This LED test system will be used as a transfer standard for
photometric, colorimetric and radiometric applications.
Specification:
• Spectral Range Wavelength: 380nm~800nm
• Spectral Wavelength Accuracy: ±0.3nm (LMS-9000B), ±0.5nm (LMS-9000A)
Wavelength Reproducibility: ±0.1nm (LMS-9000B), ±0.5nm (LMS-9000A)
• Sample Scanning Steps: ±0.1nm
• Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.002 (LMS-9000B) and ±0.003 (LMS-9000A)
• Correlated Color Temperature CCT: 1,500K~100,000K (LMS-9000B), 1,500K~25,000K (LMS-9000A)
CCT Accuracy: ±0.3% (LMS-9000B), ±0.5% (LMS-9000A)
• Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Photometric linear: ±0.3% (LMS-9000B) and ±0.5% (LMS-9000A)
• Stray light: <0.015%(600nm) and <0.03%(435nm)
• Time of integration: 0μs-10s (LMS-9000B) and 0.1ms~20s (LMS-9000A)
• Total flux measuring ways: Spectrum (LMS-9000B/LMS-9000A), Photometric (LMS-9000B)
and Spectrum with Photometric revision (LMS-9000B)
• It can measure the temperature inside and outside of integrating sphere
LMS-9000B/LMS-9000A High precision CCD Spectroradiometer
LMS-900AB/LMS-9000A used the Band pass-filter Wheel Correcting Technique, Spectrometer &
Broadband-radiometer & photometer Combined Technique, and modified NIST stray light correction
technology, the LMS-9000B/LMS-9000A spectroradiometer can realize ultra low stray light and super
photometry linearity in overall dynamic range.
8
Part 2 Spectroradiometer
LISUN GROUP
Scientific Grade CCD Spectroradiometer(LMS-8500)
LMS-8500 Scientific Grade CCD Spectroradiometer fully meets Energy Star IESNA LM-79 and GB/T
24824 standards etc. It is test for CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach
the scientific grade measurement accuracy. LMS-8500 is composed of Concave Average Diffraction Grating
and Scientific Grade CCD, and uses unique stray light control technology, wide dynamic linear technology,
precision CCD electronic drive technology and complex matrix software technology, the instrument can be
traceable to the Chinese National Institute of Metrology(NIM) and the USA NIST standards.
LMS-8500 can work with LSG-1800/LSG-1700/LSG-1600 series Goniophotometer, to test special CCT
Distribution and other Spectral color parameters.
Specification:
CCD Detector: HAMAMATSU with Back-illuminated CCD
CCD Pixels: 2048. Grating:Flat field holographic concave diffraction grating
It can do spectroscopic methodology, photometric methodology, spectrophotometric methodology
The lumen flux can measure under spectral, photometric or photometric with spectral revision
Spectral Wavelength Range: 380nm~800nm (Optional: 200nm~800nm UV-VIS or 380~1050nm VIS-NIR)
Spectral Wavelength Accuracy: ±0.2nm, Wavelength Reproducibility: ±0.1nm
Sample Scanning Steps: ±0.1nm
Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.0015. Reproducibility: x=±0.00015, y=±0.0002
(based on standard illuminate A)
• Correlated Color Temperature CCT: 1,000K~100,000K, CCT Accuracy: ±0.3%
• Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Luminous Intensity Measurement Range: 1mcd~999.9cd(need to work with Intensity Test Device)
• Flux test range: 0.01lm~999.9klm(according to the size of integrating sphere)
• Photometric Accuracy: Class A
• Time of integration: 0μs-10s
•
•
•
•
•
•
•
•
9
Part 2 Spectroradiometer
LISUN GROUP
CCD Spectroradiometer (LMS-8000A, LMS-8000)
LMS-8000A/LMS-8000 LED Measurement System is
an automated measurement system for identifying
the performance of individual LED. It is designed to
have a capability of producing any visible spectral
distribution, mimicking various light sources in the
visible region by feedback control of the radiant power
emitted by individual LEDs. This LED test system will
be used as a transfer standard for photometric,
colorimetric and radiometric applications.
The LMS - 8000AS/LMS8000S is updated on LMS - 8000A/LMS-8000 . It can connect with two
integrating spheres : the big one is for LED luminaries and the small one is for LEDs & LED modules .
The software can be chosen between the two integrating spheres to test . This new technology can
save a lot of time and length the use life of the optical fiber & detectors.
Specification:
•
•
•
•
•
•
•
•
•
•
Spectral Wavelength Range: 380nm~800nm (Optional: 200nm~800nm or 380~1050nm)
Spectral Wavelength Accuracy: ±0.5nm, Wavelength Reproducibility: ±0.2nm
Sample Scanning Steps: ±0.1nm
Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.003
Correlated Color Temperature CCT: 1,000K~100,000K, CCT Accuracy: ±0.3%
Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
Time of integration: 0.1ms~20s
Built-in a 5000.0mA Constant Current DC Power Source which can light on standard lamp
It can work with an intensity device (ITD-8000) to test the single LED intensity directly
LMS-8000A without the screen windows and button in the front of instrument.
Quick-Scan Spectrophotometer Colorimeter (LMS-5000)
LMS-5000 Quick-Scan Spectrophotometer Colorimeter
is a very widely applied single monochromators
spectrophotometer with high accuracy. A typical measuring
time during the spectral range from 380~800nm is
less than 10 seconds. LMS-5000 used with right size
integrating sphere and standard light source can be
applied to do spectral measurement of LEDs, LED
modules, CFL, Fluorescent Lamp, CCFL, HID lamps and
other luminaries.
Specification:
•
•
•
•
•
•
•
•
•
•
•
High accuracy and high speed test less than 10 seconds for LMS-5000
Spectral Range Wavelength: 380nm~800nm (Option is LMS-5000UV: 200nm~800nm UV-VIS)
Spectral Wavelength Accuracy: ±0.2nm, Wavelength Reproducibility: ±0.1nm
Sample Scanning Steps: 5nm (Optional: 1nm)
Accuracy of Chromaticity Coordinates (Δx, Δy): ±0.0003 (based on standard illuminate A)
Correlated Color Temperature CCT: 1,000K~100,000K, CCT Accuracy: ±0.3%
Color Rendering Index Range: 0~100.0. Accuracy: ±0.3% (based on standard illuminate A)
Photometry linearity: ±0.3%. Photometer detector: Class A
Luminous Flux: 0.01lm~1,999,900lm (Equipped with right size of integrating sphere)
Environment temperature measure range: -10°C~100°C, Accuracy: ±0.1°C
Temperature measure range (In sphere): -10°C~100°C, Accuracy: ±0.1°C
10
Part 2 Spectroradiometer
LISUN GROUP
Fiber Optic Spectrometer (LMS-1000)
LMS-1000 Fiber Optic Spectrometer is applied with TOSHIBA TCD1304DG linear array CCD detector,
measurement speed is very quick and cost-saving.
• The following wavelength range is with 0.8nm FWHM:
LMS-1000UV
LMS-1000UV-VIS
LMS-1000VIS
200~400nm
200~800nm
380~800nm
LMS-1000VIS-NIR LMS-1000UV-VIS-NIR
380~1050nm
200~1050nm
• Integrating time is 1ms to 60s
• CCD Detector is 3648pix which size is 8μm×200mμm
• SNR (Signal to Noise Ratio) is 1000:1 (Full range). A/D is 16bit
• Communicate with PC by USB2.0. The software has a rich re-develop platform which can be run in WinXP
and Win7.
• Optical port is SMA905
Typical Application:
The LMS-1000 is for LED Color & Photo measurement. It works with a small size integrating sphere
and standard lamp as a test system. This system can do the following test.
Measurement:
Colorimetric: Chromaticity Coordinates (x, y) and (u, v), Relative Spectral Power Distribution P(λ),
Correlated Color Temperature (Tc), Color Rendering Index (Ra, R1 to R14), Color Difference, Dominant
Wavelength, Peak Wavelength, Half-bandwidth, Spectral Purity
Photometric: Luminous Flux
Specification:
• Spectral Resolution: ±0.2nm
• Reproducibility: ±0.5nm
• Accuracy of Chromaticity Coordinates (Δx, Δy):
±0.003
• Correlated Color Temperature CCT: 1,500K~
25,000K (±3%)
• High spectral resolution, High sensitivity and
excellent reliability
Other Application:
The LMS-1000 works with other accessories, it can be used to do test and analysis in the following field
and area.
11
Part 3 Integrating Sphere
LISUN GROUP
Integrating Sphere with Testing Holder Base (IS-*MA)
Due to the LED luminaries such as LED street luminaries developed, to do 4π geometry testing, it is hard
to be hold in the traditional integrating sphere design. To solve this problem, Lisun design this new kind of
sphere.
1. The hold base can bear max 20kg, it can expanding to test all lamps such as E27/E40, all tubes such as
T5/T8/T12, and all kinds of luminaries
2. The hold base can be installed in the ceiling or down, it can be adjusted the height
3. Hold base has four power cables connect to the outside Power Supply and max is 5KW
4. The holder base is detachable. For some kinds of light sources you may need to change the position of
the holder base.
5. Diameter: IS-0.3M (Φ0.3m), IS-0.5M (Φ0.5m), IS-1.0MA (Φ1.0m), IS-1.5MA (Φ1.5m), IS-1.75MA
(Φ1.75m), IS-2.0MA (Φ2.0m). Other sizes can be designed according to the customer’s request.
6. The painting of integrating spheres is according to CIE Pub. No.84 (1989)
Integrating Sphere theory and Applications:
The integrating sphere works with a Spectroradiometer to do the photometry, colorimetry and
radiometry parameters measurement:
• IS-0.3M/IS-0.5M is suitable for LEDs, LED modules, High Power LED, mini bulbs and other small
lamps. The flux testing range is 0.001 to 1,999 lm
• IS-1.0MA is for suitable CFL or LED bulbs. The flux testing range is 0.1 to 199,990 lm
• IS-1.5MA/IS-1.75MA is suitable for CFL, LED bulb and tube, fluorescent lamp, CCFL. The flux testing
range is 0.1 to 1,999,900 lm
• IS-2.0MA is suitable for HID lamps or high power lamps. The flux testing range is 0.1 to 1,999,900lm
12
Part 3 Integrating Sphere
LISUN GROUP
Integrating Sphere with Side Assistant Opening (IS-*MA**P, IS-*MA**C)
According to IES LM-79 Clause 9.1.2, it request the 4π geometry configuration and 2π geometry
Integrating Sphere for the LED Testing. Lisun Group developed the integrating sphere with side assistant
Opening in A Molding Technology to meet the requirements.
The traditional integrating sphere is assembled by several pieces. Lisun Group developed A Molding
Technology to produce the sphere. A Molding Integrating Sphere will be more round and the test results
will be more accuracy than the traditional integrating sphere.
Specification:
• Painting material of integrating spheres is according to CIE Pub.No.84(1989)
• The painting material is BaSO4 coating: ρ(λ)≥0.96(450nm~800nm) and ρ(λ)≥0.92(380nm~450nm)
• Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ(λ)<1.5%
• Build-in all functional lamp testing jigs: the vertical is for E40/E27, the horizontal is for T5/T8/T12
tubes and the Testing Holder Base for LED street luminiares. All of the testing jigs can allow the lamp
be tested up and down in the sphere.
• Power Cable, Power Terminal and Auxiliary lamp position has been built-in (Auxiliary lamp is option).
• Two photo detector ports, one optical fiber port and temperature sensor hole are built-in
• Ordering Code: IS-1.5MA55P or IS-1.5MA55C (Φ1.5m, IS-1.5MA55P means square side opening is
0.5x0.5m, IS-1.5MA55C means cycle side opening diameter is 0.5m). IS-1.75MA66P or IS-1.75M66C
(Φ1.75m and side opening is 0.6m). IS-2.0MA77P or IS-2.0MA77C (Φ2.0m and side opening is 0.7m).
Other size such as diameter 2.5m, 3.0m can be special order according to customer’s request.
Fig: LM-79 Clause 9.1.2
13
Part 3 Integrating Sphere
LISUN GROUP
Constant Temperature Integrating Sphere (IS-*MT)
According to requiremenst of IEC standards, the standard test temperature is 25℃, but high power
lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the
temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group
designed the Constant Temperature Integrating Sphere which allows the lamp to be tested in a constant air
temperature.
Specification:
• Diameter: IS-0.3MT (Φ0.3m), IS-0.5MT (Φ0.5m), IS-1.0MT (Φ1.0m), IS-1.5MT (Φ1.5m), IS-1.75MT
(Φ1.75m), IS-2.0MT (Φ2.0m). Other size can be designed according to the customer’s request.
• Painting of integrating spheres is according to CIE Pub. No.84 (1989).
• Material: Pure barium soleplate (BaSO4).
• BaSO4 coating: ρ(λ)≥0.96 (450nm~800nm) and ρ(λ)≥0.92 (380nm~450nm).
• Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ(λ)<1.5%.
• Build-in all functional lamp testing jigs: the vertical is for E40/E27, the horizontal is for T5/T8/T12
tubes and the Testing Holder Base for LED street luminiares. All of the testing jigs can allow the lamp
be tested up and down in the sphere.
• Auxiliary lamp position has been built-in. Auxiliary lamp and Auxiliary lamp device are optional.
• Power cable and socket has been build-in, it is convenient to power the testing lamp.
• Two photo detector ports, one optical fiber port and temperature sensor hole are built-in.
• Constant Temperature controlled range: 25°C~55°C (refer to the environmental temperature at 25°C).
A. Temperature Increasing tolerance: ±1°C
B. Temperature Down tolerance: ±2°C
Application:
The integrating sphere works with a Spectrophotometer to do the photometry, colorimetry and
radiometry parameters measurement:
• IS-0.3MT/IS-0.5MT is suitable for LEDs, LED modules, High Power LED, mini bulbs and other small
lamps. The flux testing range is 0.001 to 1,999 lm.
• IS-1.0MT is suitable for CFL or LED bulbs. The flux testing range is 0.1 to 199,990 lm.
• IS-1.5MT/IS-1.75MT is suitable for CFL, LED bulb and tube, fluorescent lamp, CCFL. The flux testing
range is 0.1 to 1,999,900 lm.
• IS-2.0MT is suitable for HID lamps or high power lamps. The flux testing range is 0.1 to 1,999,900 lm
UV-VIS High lndex of Reflective Coating
14
VIS High Index of Reflective Coating
Part 4 LED Test Instruments
LISUN GROUP
Integrating Sphere Spectroradiometer System for LED (LPCE-2)
LPCE-2 is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of
single LEDs and LED lamps. LED's quality should be tested by checking its photometric, colorimetric and
electrical parameters. According to CIE127-1997, IES LM-79-08 and IES LM-80-08, it recommends to using
an array spectroradiometer with integrating sphere to test SSL products. The LPCE-2 system is applied
with a CCD Spectroradiometer (LMS-9000 or LMS-8000) and worked with A molding integrating sphere
with testing holder base function which will be more circle and the test results will be more accurate than the
traditional integrating sphere
System Configuration:
High Precision CCD Spectroradiometer (LMS-9000 or LMS-8000), Optical Fiber (CFO-1.5M), Digital Power
Meter(LS2012 or LS2050), DC Power Source (DC Series), AC Power Source (LSP-500VAR or LSP-1KVAR),
Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), Optical Path
Converter (LS512B), 19 Inch Cabinet (CASE-19IN)
Measurement:
• Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant
Wavelength, Color Purity, CRI, Spectrum Test
• Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, Pupil Flux, Pupil Flux Efficiency, Pupil
Factor, Cirtopic Flux
• Electric: Voltage, Current, Power, Power Factor (Option: VF, IF, VR, IR)
• LED optical maintenance test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS
time, Power Factor VS time, Current VS time and Flux Efficiency VS time.
Specification:
• Spectral Range Wavelength: 380nm~800nm (LMS-8000 Option: 380nm~1050nm or 200nm~800nm).
• Spectral Wavelength Accuracy: ±0.3nm, Wavelength Reproducibility: ±0.1nm
• Sample Scanning Steps: ±0.1nm
• Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.002
• Correlated Color Temperature CCT: 1,000K~100,000K, CCT Accuracy: ±0.3%
• Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Photometric linear: ±0.3%
• Stray light: <0.015%(600nm) and <0.03%(435nm)
• The system includes the auxiliary lamp device and the software includes self-absorption function
• The system can test the inside and outside integrating sphere temperature
• Connect with PC via USB, English version software can be run under WinXP, Win7 and Win8
• The LM-79 Photometric, Color and Electricity report can be exported PDF and LM-80 LED Optical Maintenance
test report can be exported Excel or PDF
15
LISUN GROUP
Part 4 LED Test Instruments
Lamp Start, Run-up time and Flicker Test System (LSRF-1)
Dated 14th December, 2012, the EU officially released the (EU)
NO 1194/2012rules <Implementing rules of the European Parliament
and the EU Council Directive 2009/125/EC on the eco-design
requirements of directional lights, LED lights and related
equipment requirements>.Compared with
<European Parliament and Council Directive 2005/32/EC
implementing rules for non-directional household lamps
eco-design requirements> which posted by theEuropean
Commission Regulation (EC) NO 244/2009 Regulations dated
18th March, 2009, the new rules have complete mandatory and eco-design requirements. Start and
Run-up time as the two indicators functional requirements in the industry has been more emphasis
by manufacturers.
To meet EU ErP requirements, IEC60969 Self-ballasted Lamps for General Lighting Services Performance
requirements and Energy Star about Lamp Start, Run-up Time and Flicker Test. LISUN developed ErP
test system, the LSRF-1 system hardware include following LISUN insruments: PH3000, IS-1.5MA, SLS-50W
and LSP-500VAC; the software include the Lamp Start, Run-up Time and Lamp Flick Test.
The LSRF-1 system can combined with LISUN LPCE-1 or LPCE-2 to test CFL or LED lamps.
Fast Photo-Electric Tester (LS616S)
The LS616S is designed in a Luggage which can be take out conveniently. The LS616S can be used to test
the CFL, Single LED, LED Spotlight and LED bulb which lamp holder is E27, E40, MR16 and so on.
Specification:
Part 4 LED Test Instruments
LISUN GROUP
LED Lumen Maintenance and Aging Life Test System (LEDLM-80PL)
LEDLM-80PL LED Lumen Maintenance and Aging Life Test System is designed according to standards of
IES-LM-80, IES-LM-82, TM-21 and GB2312-80, and the software is developed base on Arrhenius model.
LED has the features of long life, but with the different working condition and drive current, its life will
be different, but generally the life will be around 50K hours. Differ from the traditional lightsource, LED
light will decay gradually rather than extinguish instantly, so in the standard of LM-80, it introduces L70,
L50 and etc.
1) L70 (hour): time to 70% lumen maintenance
2) L50 (hour): time to 50% lumen maintenance
Features:
1) Record the changing curves of lumen VS time, and colorimetric parameters VS time
2) Test and record the light attenuation data within a short time, then software will predict the LED life
3) Introduce the Arrhenius Model to make the test result more reliable and effective
System Configuration:
LM-80PL LED Aging Control System with Arrhenius software, TMP-8 Multiplex Temperature Meter,
LMS-4000 Quick Test System for Photo and Color, CFO-1.5M Optical Fiber, LS2008R Digital Power Meter,
LSP-18CH The Switching Power System for the LED lamp, CASE-19IN Cabinet
The Life Calculated by TM-21:
P.S The LEDLM-80PL needs to work with a GDJW Series High and Low Temperature Chamber and an LSP
Series AC Power Source.
Lumen Maintenance Life Prediction Report
Lumen Maintenance Graph
17
Part 4 LED Test Instruments
LISUN GROUP
LED Power Driver Tester (WT2080)
WT2080 LED Power Driver Test Instrument is the comprehensive test instrument for LED drive power
which is according to GB/T 24825-2009 and IEC 62384:2006. It can measure the following parameters:
Input Characteristics Test (AC&DC), Output Characteristics Test (AC&DC), Output Start Characteristics
Test (DC)
Specification:
1. Input Characteristics Test (AC)
• To measure the input voltage, current, power, power factor, power grid frequency
• The fundamental frequency scope of the current and voltage: 45Hz~65Hz; Narrow band range:
45Hz~5kHz; Broadband range: 45Hz~1MHz.
• Voltage range: 3~300V (CF=1.67); Current range: 5mA~2.7A (CF=3); Power range: 0.015~800W;
Power factor range: 0.000~+1.000.
2. Input Characteristics Test (DC)
• Measuring voltage, current, power.
• Voltage range: 3~500V; Current range: 5mA~8A; Power range: 0.015~4KW
3. Output Characteristics Test (AC)
• Measuring lamp voltage, lamp current and lamp power.
• Lamp voltage range: 3~300V(CF=3); Lamp current range: 5mA~2.7A(CF=3); Lamp power range:
0.015~800W
4. Output Characteristics Test (DC)
• Measuring output lamp voltage, lamp current, lamp power, ripple wave current.
• Voltage range: 3~500V; Current range: 5mA8A; Power range: 0.015~4KW; Ripple wave current:
5mA~2.5A.
5. Output Start Characteristics Test (DC)
• Change curve and data of the measuring lamp voltage and lamp current within 0~2 seconds.
• Lamp voltage range: 3~500V; Lamp current range: 5mA~8A
6. Harmonic Testing
• Total Harmonic test and harmonic components of 0~50times, wave ratio, initial phase angle and peak
phase angle
Input Characteristics
Start Characteristics
18
Input & Output Characteristics
Part 4 LED Test Instruments
LISUN GROUP
LED Power Driver on line Tester (WT2080-OK)
WT2080-OK LED Power Driver on line Tester is according to GB/T 24825-2009 and IEC 62384:2006. It
suitable for LED Driver production line testing quick test (0.1s finish the testing). The WT2080-OK can
test 1pc LED Driver at one time in the production line.
Specification:
1. Input Characteristics Test (AC)
• To measure the input voltage, current, power, power factor, power grid frequency
• The fundamental frequency scope of the current and voltage: 45Hz~65Hz; Narrowband range:
45Hz~5kHz; Broadband range: 45Hz~1MHz.
• Voltage range: 0.15~300V (CF=1.67); Current range: 1.5mA~2.7A (CF=3); Power range:
0.015~800W; Power factor range: 0.000~1.000.
2. Input Characteristics Test (DC)
• Measuring voltage, current, power.
• Voltage range: 0.15~500V; Current range: 1.5mA~8A; Power range: 0.015~4KW
3. Output Characteristics Test (AC)
• Measuring lamp voltage, lamp current, lamp power.
• Lamp voltage range: 0.15~300V (CF=3); Lamp current range: 1.5mA~2.7A(CF=3); Lamp power
range: 0.015~800W
4. Output Characteristics Test (DC)
• Measuring output lamp voltage, lamp current, lamp power, ripple wave current.
• Voltage range: 3~500V; Current range: 1.5mA~8A; Power range: 0.015~4000W; Ripple wave
current range: 5mA~2.5A.
LED Driver Online Tester (LSLED-12)
LSLED-12 LED Driver on line tester is according to IEC62384:2011 and GB/T 24825-2009.
• The tester includes A Group Measuring Module and B Group Measuring Module. The A Group measuring
module can test 6pcs LED Drivers AC Parameters. The B Group measuring module can test 6pcs LED
Drivers’ AC, DC and AC/DC Parameters.
• There are 12 windows to display the input and output parameters, it is good for comparing and analyses.
• Quick test for all of the parameters in 0.1seconds.
• It can set up the testing parameters PASS/FAIL range, it will have Noise/Light warning if it is Fail. We
also supply handle port (Extra cost)
• Software communicate with PC (Extra cost)
Specification:
1) A Group Measuring Module (For AC Parameters Testing):
• Measuring Input Voltage, Current, Power and Power Factor
• Voltage and Current Fundamental Frequency: 45Hz~65Hz, Response Frequency: 45Hz~1MHz
• Voltage Range: 0.15~300V (CF=1.67), Current Range: 1.5mA~2.7A (CF=3), Power Range:
0.015~800W, Power Factor Range: 0.000~1.000
2) B Group Measuring Module (For AC Parameters Testing):
• Measuring Output Voltage, Current, Power and Power Factor
• Voltage Range: 0.15~300V (CF=1.67), Current Range: 1.5mA~2.7A (CF=3), Power Range:
0.015~800W, Power Factor Range: 0.000~1.000
3) B Group Measuring Module (For DC Parameters Testing):
• Measuring Lamp Voltage, Current, Power and Ripple Current
• Voltage Range: 0.15~500V, Current Range: 1.5mA~8A, Power Range: 0.015~4KW, Ripple
Current Range: 5mA~2.5A.
19
Part 4 LED Test Instruments
LISUN GROUP
LED Power Driver Automatic Test System (ATE-2)
ATE-2 LED driver automatic test system is applied to the production line for the finished products testing.
With features of simplified operation and nice-looking, the workers can operate it at very short time. This
system can meet the requirements of IEC62384, GB24825-2009 and other relative standards.
Specification:
•This system includes 2 groups (left and right); the 2 groups can work in
turn, so that to improve the work efficiency. For example, if the left is on
working, then the right can make wire connection.
•It can test 4 LED drivers input and output at one time.
•The equipment can connect with electronic load and LED lamps, the two
difference loads can be fast switch under the control of computer.
•Enable to print out the series number and parameters of sub-quality
products by working with a micro-printer.
•Enable to achieve the bar-code record function by working with a bar-code
scanner.
•The test report can be saved as Excel file for consult, statistic and analysis
purpose.
•Good software interface to freely choose the difference parameters
combination, so that to meet different demands. All the parameters can set
limit, and with the quality analysis function.
Item
Voltage
Test Range
Tolerance
Test Condition
AC: 3~300V (CF=1.67)
DC: 3~500V
AC: 5mA~2.7A (CF=3)
Current
DC: 5mA~8A
Power
±(0.1%reading+0.1%range+1digit)
AC: 0.015~800W
45~65Hz sine-wave
Calibration validity: 12 months
DC: 0.015~4000W
0.000~1.000
±(0.002+0.001/reading+1digit)
Frequency
45Hz~65Hz
±0.1% Reading
Harmonic
Total harmonic, and 2-11
±(0.1% range+5% Reading)
times harmonic component
Power Factor
Surge Current
Lamp Voltage
50mA~100A
Square wave with pulse width
±(0.5% range+0.5% range+1digit) greater than 10 10μs
Calibration validity: 12 months
AC: 3~300V (CF=1.67)
DC: 3~500V
Lamp Current
AC: 5mA~2.7A (CF=3)
DC: 5mA~8A
Lamp Power
45~65Hz sine-wave
±(0.1%reading+0.1%range+1digit) Calibration validity: 12 months
AC: 0.015~800W
DC: 0.015~4000W
Ripple Current
Max: 5mA~8A
±(1%reading+1%range)
20
20-70kHz sine-wave
Part 5 CFL Test Instruments
LISUN GROUP
Spectrophotometer & Integrating Sphere Test System (LPCE-1)
This Test System is suitable for photometric and colorimetric measurement of luminaries such as Energysaving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps),
CCFL and LED. The measured data meets the requirements of CIE and IES LM-79 for the measurement
of photometry and colorimetry.
System Configuration:
Quick-Scan Spectrophotometer Colorimeter (LMS-5000), Optical Fiber (CFO-1.2M), Digital Power Meter (LS2012
or LS2050), DC Power Supply (DC Series), AC Power Source (LSP-500VAR or LSP-1KVAR), Integrating Sphere
(IS-1.5MA or IS-2.0MA), Standard Lamp Source (SLS-50W), CASE-19IN 19Inch Cabinet
Spectrophotometer integrating sphere system measures photometry, colorimetry and electricity:
• Color parameters: chromaticity coordinates, CCT (correlated color temperature), CRI (color rending index),
color difference, peak wavelength;
• Photometry parameters: luminous flux, luminous power, luminous flux efficiency;
• Electrical parameters: voltage, current, power, power factor.
Specification:
•
•
•
•
•
•
•
•
•
•
•
•
High accuracy and high speed test less than 10 seconds
Spectral Range Wavelength: 380nm~800nm (Option: 200nm~800nm UV-VIS)
Spectral Wavelength Accuracy: ±0.2nm, Wavelength Reproducibility: ±0.1nm
Sample Scanning Steps: 5nm (Optional: 1nm)
Accuracy of Chromaticity Coordinates (Δx, Δy): ±0.0003(based on standard illuminate A)
Correlated Color Temperature CCT: 1,000K~100,000K, CCT Accuracy: ±0.3%
Color Rendering Index Range: 0~100.0, Accuracy: ±0.3%(based on standard illuminate A)
Photometry linearity: ±0.3%, Photometer detector: Class A
Luminous Flux: 0.01lm~1,999,900lm (Equipped with right size of integrating sphere)
Environment temperature measure range: -10°C~100°C, Accuracy: ±0.1°
Communicate with Digital Power Meter to display the Voltage, Current, Power and Power Factor
Connect with PC via USB, English version software can be run under WinXP, Win7 and Win8
Photo, Color & Electric Report
Fluorescent Lamp Start-up Time Report
21
Part 5 CFL Test Instruments
LISUN GROUP
High Frequency Fluorescent Lamp Test System(HFP-800, RB-3 and LPS-3)
This High Frequency Fluorescent Lamp Test System includes HFP-800 (High Frequency Power Supply ),
LPS-3 (Auxiliary Power Supply) and RB-3 (Adjustable Resistance Ballast). This system is applied to all
kinds of fluorescent lamp such as 50Hz/60Hz T8/T12 or 25KHz T5 Tube test. The system is according
to Double end fluorescent lamp adopts the IEC 60081 (GB/T10682) and the single-ended fluorescent
lamp adopts the IEC60901 (GB/T17262), where in the standard of electricity parameters as in Fig 1
S2
S3
A
Adjustable Resistance Ballast
RB-3
Tube
S1
Metal Board to Earth
HFP-800 High Frequency Power Source
LPS-3
Lamp Preheat Assistant Source
A
Fig 1 Preheating Method of Cathode High Frequency Fluorescent Lamp
High Frequency Power Supply (HFP-800):
output power is 20~26kHz (meets the requirements
of IEC 60081:1997), the frequency should be kept in
the range of ±2% at working. Output Power Range
is 0~600V (Adjustable). Range for output current:
0~0.600A. Range for output power: 0~300W
Adjustable Resistance Ballast (RB-3):
impedance values of high frequency reference
ballast which used by any high frequency lamp with
regard to GB/T10682 (IEC 60081) and GB/T17262
(IEC60901), RB-3 conforms to the requirements of
IEC60929 and ANSI C82.11. Available current range:
0~0.700A. Impedance range: 100~2047Ω
Lamp Preheat Assistant Source | Auxiliary
Power Supply (LPS-3): Preheating method of
cathode during the high frequency fluorescent lamp
starting. Adjustable pre-heat time for filament is
0~10.00s.
22
A
Part 5 CFL Test Instruments
LISUN GROUP
Adjustable Reference Ballast (DYJ-50HZ, DYJ-60HZ, DYJ-HID)
According to double end fluorescent lamp of IEC 60081 (GB/T10682), the single-ended
fluorescent lamp of IEC60901 (GB/T17262), ANSI C78.81 and ANSI C82.3, DYJ Reference Ballast is
used to test for 4W~85W fluorescent lamp and electronic ballast test.
Specification:
• Inductance: 0~1240Ω (adjustable)
• Inductance Power Factor COSφ: 0.075~0.120
• Resistance: 0~111Ω (adjustable)
• Current Range 0.150~0.670A (Imax: 1A)
• Order Code: DYJ-50HZ is for 50Hz lamp test
and DYJ-60HZ is for all 60Hz lamps test
According to IEC60188, IEC60662 and ANSI C82.5, Lisun Group developed the DYJ-HID Standard Ballast
(Reference Ballast) to test the HID lamp, HID ballast, High-Voltage Mercury Lamp, High Voltage Sodium
Lamp, Metal Halide Lamp and Halide Reactor. More information, please contact Lisun Group.
Adjustable High Frequency Reference Ballast (HCS-105A)
HCS-105A includes two functions: Adjustable High Frequency Reference Ballast and High Frequency
Digital Power Meter. This instrument is used for high frequency fluorescent lamp such as T5 tube,
power frequency fluorescent lamp such as T8/T12 tube and ballast manufacturing. Comparing to
IEC Test Method, HCS-105A is an Equivalent Test Method which is economic solution. HCS-105A
equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo,
color and electricity parameters for high frequency fluorescent lamp.
Specification for Adjustable High Frequency Reference Ballast:
• Input voltage: 200V~240V, 50/60Hz
• Input power: 150Wmax
• Output frequency: 23~26KHz (meets the requirements of GB/T 10682-2002 and IEC 60081:1997)
• Output current total harmonic wave distortion: THD<2.5% (HF current wave)
• Output current: 100mA~600mA, five ranges can be adjusted continuously
• Output current stability: +/-0.5%
Specification for High Frequency Digital Power Meter:
• Measure Vrms, W, PF/Hz
• Voltage Range: 10~600V, Current Range: 10~2000mA
• Frequency Range: 20kHz~70kHz
• Accuracy: Class 2
Multiplex Temperature Tester (TMP-8, TMP-16)
Specification:
• 8 channels temperature signal(TMP-8) or 16 channels
temperature signal(TMP-16)
• T type or K type thermocouple
• Temperature range: -40~300°C. Testing accuracy: 0.5%
• Channel sequence is displayed by 2 LED and temperature is
displayed by 4 LED
• Freely set up the software with PC and record the change of
temperature and select the channel.
23
Part 5 CFL Test Instruments
LISUN GROUP
Multiway Life Tester (CH316)
Feature:
• Measure 16 samples at the same time, evaluate and record the
life of each sample.
• Very flexible: Samples can be added and changed at anytime.
• The life of each sample is readable at anytime.
• The switch ON/OFF time is adjustable (Test period is min 1s).
• Automatically remember the test result when the power is off,
and resume the old measurement when power is on.
• Sound and light alarm when the products were failed.
Specification:
• Current range (normal load): 30mA~1000mA (RMS). Invalid if the load current is smaller than 30mA.
• Tested sample life range: 0~1,000,000 times.
• Switch on or switch off time can be set at: 1 second~99 hours 59 minutes 59 seconds.
Digital Torsion Meter (CH338)
Digital Torsion Meter is mostly applied to measure the torque of all kinds of luminaries lamp cap. The
CH338 is a newly developed intelligent product with microprocessor built-in.
Specification:
• Range: 0~10N•m; Accuracy≤1%
• Repeatability≤0.5%FS; Over loading: 120%FS
• It can measure the clockwise and anti-clockwise torque of lamp
cap and it can preset upper limit alarm. The data won’t be lost
after shutting down the instrument.
• Instrument is convenient to be used because it has several
mating clamps of various lamp caps such as E27/E26, B22d,
E14/E12, G13/G5 and so on.
"Go" and "Not Go" gauge (GNG-E27)
Specification:
According to the requirement of IEC60061, Lisun produced high
accuracy and high quality "Go" and "Not go" gauge
• GNG-E27 is for E27 lamp cap standard source measurement. It
includes 7006-27B-1, 7006-28A-1, 7006-27C-1, 7006-50-1, 7006
-51A-2, 7006-51-2
• GNG-E27H is for E27 lamp holder standard source measurement.
It includes 7006-25A-2, 7006-26-4, 7006-21-5, 7006-22A-4, 7006
-22B-1, 7006-22C-1, 7006-22D-1
• GNG-E14 is for E14 lamp cap standard source measurement:
7006-27F-1, 7006-54-2, 7006-27G-1, 7006-55-2
• GNG-E40 is for E40 lamp cap standard source measurement:
7006-27-7, 7006-28D-1, 7006-52-1, 7006-53-1
• GNG-B22D is for B22d lamp cap standard source measurement:
7006-12-8, 7006-15-7, 7006-20-4, 7006-12A-2, 7006-12B-2,
7006-15A-2, 7006-13-5, 7006-17B-1
• GNG-B22DH is for B22d lamp holder standard source
measurement: 7006-12A-2,7006-12B-2,7006-15A-2,7005-10-8
24
Part 6 Photometer and Colorimeter
LISUN GROUP
Luminance Colorimeter (XYL-VI)
The XYL-VI Luminance Photoelectric Colorimeter changes the traditional structure thoroughly, employs
the digital X(λ),Y(λ),Z(λ) sensors to replace the traditional analogue sensors, employs the digital signal
measurement system to replace the traditional analogue measurement system. The instrument has no
analogue unit, thus it is very simple to overcome the zero drift that is impossible to be avoided in
traditional colorimeter. The digital sensor has a large dynamic range. Moreover, it possesses strong antiinterference ability and it has high accuracy.
The XYL-VI Luminance Colorimeter contains internal RS232 computer interface. The calibration is done by
software. It is suitable for monitoring and remote applications. The XYL-VI Luminance Colorimeter can be
calibrated by XYL-VI Luminance Colorimeter software to sample the data and print out the results. It can
also be corrected by other standard light sources to obtain very high measuring accuracy of x, y color
coordinates and color temperature. It is a real-time measuring system and run under PC.
Specification:
• Luminance Y:
Relative spectral sensitivity of digital V(λ) sensor: f1<5.5%
Dynamic range: 10~1,000,000 cd/m2. Accuracy: <5%
Sensitivity: 0.01cd/m2. Repeatability: 0.01cd/m2
• Measuring angle: 1 degree. Measuring distance: 0.7m to infinity
• Color Coordinates x, y, u, v(u', v'): (Luminance more than 10cd/m2)
Accuracy(x, y): ±0.002(CIE Standard A-source, 100cd/m2)
Repeatability(x, y): ±0.0005(CIE Standard A-source)
• Color Temperature Tc: (Luminance more than 10cd/m2)
Dynamic range: 1,350~25,000K Sensitivity: 1K
Accuracy: ±20K(CIE Standard A-source, 100cd/m2)
• Temperature effect: -0.1%. No range-changing error
• Refreshing frequency: 1n/s(no less than 10 cd/m2), 1n/3s(less than
10cd/m2 )
• 128×64 LCD display. Data hold function
• RS232 computer interface and software
• Power Supply: 9V Battery, 6V DC adapter
• Size: 270*95*225(mm) (Tripod is option).
Photometer (PH2000)
Specification:
Flux or Lumen measure range depends on the
size of the integrating sphere
-7
• Light current measuring range: 0.005x10 ~
-7
2,000x10 A
• User can do ZERO and Calibrate by operating
the keys on the front of panel
• Photo Detector: Class 1
• High correcting accuracy of photo detector V(λ)
• English Software can be run in Win7 or Win8
by RS-232 (option)
25
Part 6 Photometer and Colorimeter
LISUN GROUP
Pocket Chroma Meter (CHROMA-2)
CHROMA-2 Pocket Chroma Meter is developed based on TOSHIBA TCD1304DG linear array CCD detector.
It makes traditional laboratory instrument available for the production on-line quality acceptance, thus
greatly improved the efficiency of fluorescent lamp, CFL and LED
Measurement:
illuminance (lux), CCT, Chromaticity Coordinates, CRI, Purity, Peak Wavelength,
Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength,
Total Color Difference, Brightness Difference, Red-Green Degree,
Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram
Specification:
•
•
•
•
•
•
•
•
•
It can measure all of the spectrum parameters and illuminance directly
It can test flux with the integrating sphere (option)
Rang of wavelength: 380nm~780nm
Accuracy of wavelength: ±0.5nm; repeatability: ±0.2nm
Accuracy of chromaticity coordinates: ±0.003; resolution: 0.0001
Correlated Color Temperature: 1,500~25,000K(±3%); Resolution: 1K
Power supply: 3.7V Li-Battery
Dimension: (Width×Height×Depth) 9cm×18cm×5cm; Weight: 1kg
The English software can be run in Win7 or Win8 via USB
Pocket Brightness Meter (PHOTO-100L)
Specification:
• Measuring range: 20cd/m2~2,000kcd/m2
• Testing accuracy: Class 1
• Display refresh rate: 1time/sec
• Power source: 9V battery
• Power consumption: less than 20mW
• Normal technical specifications:
1) Temperature: 0~40℃
2) Relative humidity: less than 90%
Pocket Illuminance Meter (PHOTO-100)
Specification:
This Pocket Illuminance Meter has performance of high precision, low consumption, small volume, stable
performance and convenience operation. It's mainly used in industrial field for illumination photometry.
Measurement:
Illuminance
Features:
• Automatic range switching, Low zero drift, high accuracy
• Measuring range: 1.0lx-200Klx Accuracy: Class 1
• Fine V(λ) and cosφ corrected detector
• Low power consumption and automatic power off
• Four-position liquid crystal indication with field angle of
larger than 60 degrees
26
Part 7 EMC and EMI Test System
LISUN GROUP
EMI Receiver System (KH3961, KH3962)
KH3962 is an automatic EMI receiver system. It is a main test system for EMI (Electro Magnetic Interference)
testing. The KH3962 is produced by the full closure structure and strong electro-conductibility material,
which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument
self-EMI problem. The test results are according to the international format test report. The EMI Test System
KH3962 fully meets CISPRl6-1, GB17743, FCC, EN55015 and EN55022.
Specification:
• Detection frequency range:9kHz~30MHz (KH3961) or
9kHz~300MHz (KH3962)
• Frequency stability: 1x 10-6
• Frequency resolution: (9kHz~150kHz) 30Hz;
(150kHz~30MHz) 1kHz
• Test Tolerance: ±2dB
• Measure and detection method: PK, QP and AV
• Measure range from 20dBμV to 140dBμV
• Frequency scanning step length: 20Hz~2MHz
• Sweep bandwidth: 200Hz; 9kHz; 120kHz
• Connect PC via USB and software can be run Win7, Win8.
Magnetic Shielding Cabinet for EMI Testing (SDR-2000B)
The SDR-2000B and SDR-800S Magnetic Shielding Cabinet is designed
according to GB/T12190:2006, GJB5792:2006, IEEE std299 and
EN50147. The shielding cabinet is tested based 9K~100K>70db and
100K~300MHz>100db. The SDR-2000B and SDR-800S can work with
KH3962/KH3961 to reduce the testing load self or environmental EMI.
Specification:
Product Model
SDR-2000B
SDR-800S
P.S. Other size can be design according to customer’s request
Note: Other size Shielding cabinet can be designed according to customer’s request
27
Part 7 EMC and EMI Test System
LISUN GROUP
Electrostatic Discharge Simulator (ESD61000-2)
ESD simulator (Electrostatic Discharge Generator or Electrostatic
Gun) is in full compliance with IEC 61000-4-2, EN61000-4-2,
ISO10605, GB/T17626.2, GB/T17215.301 and GB/T17215.322.
The ESD generator is designed for the assessment of electrical and
electronic equipment to withstand ESD performance. ESD61000-2
/ESD61000-2A has LCD display in both English and Chinese, they
equipped with an infrared remote control which can allow you do
the test in some special place.
Touch screen with super big LCD and built-in Windows CE
Specification:
ESD61000-2A
ESD61000-2
Product Model
Output Voltage
0.1~20kV±5%
0.1~30kV±5%
Polarity
Positive/Negative
Positive/Negative
Energy Storage Capacitance 150pF±10% (Replaceable)
150pF±10% (Replaceable)
Discharge Resistor
330Ω±5% (Replaceable)
330Ω±5% (Replaceable)
Current Rise Time
0.6~1ns
0.6~1ns
Testing Functions
Single, Count, 20pps, Air, Contact, IEC level Single, Count, 20pps, Air, Contact, IEC level
Trigger Mode
MANUAL/AUTO
MANUAL/AUTO
Numbers of Discharge
1~9999
1~9999
Repetition
0.05s~99.99s
0.05s~99.99s
Working Power
AC220V(Option 110V)±10%, 50/60Hz
AC220V(Option 110V)±10%, 50/60Hz
EFT
EFT Immunity
Immunity Measurement
Measurement (EFT61000-4)
(EFT61000-4)
EFT immunity tester EFT61000-4 is specially designed according to the characteristics and requirements of
EFT measurement and it is an ideal disturbance source of EMS measurement. They have fine performance,
such as high stability, high reliability, easy to use and etc. It meets the standard requirements of IEC 61000
-4-4, EN 61000-4-4, GB/T17215.301, GB/T17215.322 and GB/T17626.4. EFT61000-4 has LCD display in
both English and Chinese.
Specification:
• Output voltage: 0~5000V
• Pulse frequency: 1kHz~1000kHz (Adjustable)
• Polarity: Positive, Negative or Positive/Negative, auto
• Source impedance: 50Ω±20% and 1000Ω±20%
• Rise time of a pulse: 5ns±30%
• Pulse width: 50Ω is 50ns±30%, 1kΩ is 35ns~150ns
• Burst duration: 0.01ms~20ms
• Burst period: 100ms~500ms, Test time: 1s~9999s
• Testing functions: Set test mode freely or IEC Level
• Coupling/Decoupling Network: Built-in 20A with
3 phases/5 wires
• Working Power: AC220V (Option 110V), 50/60Hz
28
Touch screen with super big LCD
and built-in Windows CE
Part 7 EMC and EMI Test System
LISUN GROUP
Surge Generator (SG61000-5)
Automatic lightning surge generator (or Lightning surge
immunity) SG61000-5 is used to assess the power cord
and connect the internal switch stood in line to connect
the internal switch to provide a common basis for switching
the natural world and lightning caused by the high-energy
transient interference performance. It is full meets the
IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards.
Touch screen with super big LCD
and built-in Windows CE
Specification:
SG61000-5T
SG61000-5
Product Model
SG61000-5H12
SG61000-5H
SG61000-5H
SG61000-5T
Output Voltage (Open) 1.2/50μs±20%
1.2/50μs±20%
1.2/50μs±20%
1.2/50μs±20%
Output Current (Short) 8/20μs±20%
8/20μs±20%
8/20μs±20%
8/20μs±20%
Output Impedance
2Ω
2Ω
2Ω and 500Ω
2Ω and 500Ω
Output Voltage Range
0~6KV±10%
0~6KV±10%
0~12KV±10%
0~10KV±10%
Output Current Range
0~3KA±10%
0~3KA±10%
0~6KA±10%
0~5KA±10%
Surge Repetition
1~9999 times
1~9999 times
1~9999 times
1~9999 times
Interval Time
20~9999s
20~9999s
20~9999s
20~9999s
Polarity
Positive, Negative or Positive/Negative automatic
Phase Shift
Asynchronous, Synchronization 0°~ 360° or Specific Angle
Coupling/Decoupling
Network (CDN)
Includes a 16A
single phase CDN
Includes a 20A
3phases CDN
Includes a 30A
3phases CDN
Built-in 20A
3phases CDN
Package Size/
Gross Weight
44x45x35cm
About 30kg
44x45x55cm
About 48kg
56x69x165cm
About 300kg
56x69x155cm
About 270kg
Impulse Withstand Voltage Tester (SUG255LX, SUG255PX)
The Impulse Withstand Voltage Tester (or High Voltage
Surge Generator) is designed according to IEC255-5,
IEC60060, GB14711, GBT17215.301 and GBT17215.322.
It is suitable for doing all kinds of electrical and electronic
products insulation performance test.
Specification:
SUG255LX
Product Model
SUG255PX
Voltage Output Waveform
1.2/50μs
1.2/50μs
Range of Output Voltage
0~12kV
0~12kV
Polarity of Output Voltage
Positive or Negative
Positive or Negative
Impedance of Generator
12Ω and 500Ω
2Ω and 500Ω
Operation Mode
Manually or Automatic
Manually or Automatic
Test Repetition
1~9999
1~9999
Interval Time
3~9999s
3~9999s
29
29
Part 7 EMC and EMI Test System
LISUN GROUP
Voltage Dips and Interruptions Generator (CSS61000-11)
The voltage dip and interruptions generator is specially designed according to the characteristics and
requirements of EMS measurement under a sudden reduction or interruption of the voltage at a point,
CSS61000-11/ CSS61000-11T used a big LCD in both English and Chinese operating interface. They have
more fine performance such as high reliability, convenient operation, and fully meet the standard
requirements of IEC 61000-4-11, EN 61000-4-11 and GB/T17626.11
Touch screen with super big LCD and built-in Windows CE
Specification:
CSS61000-11
CSS61000-11T
AC Sine Wave
AC Sine Wave
0~110% of 220V
0~110% of 380V
100%, 80%, 70%, 40%, 0%
100%, 80%, 70%, 40%, 0%
0°~360°(1° Step)
0°~360°(1° Step)
Duration Time of Voltage
Variation
0.5~9999.5T
0.5~9999.5T
Internal Time of Voltage
Variation
1s~9999s
1s~9999s
Voltage Dip Count
0~9999 times
0~9999 times
Operating Mode
Automatic Dip
Choose 1 to 3 phases to automatic
dip at the same time
Product Model
Wave Generator
Range of Voltage Variations
IEC Level Build-in
Dip Phase Set
Trigger Mode
Power Capacity For EUT
Working Power
Manual, Auto and 50ms
Manual, Auto and 50ms
Single Phase AC 220V±10%, 16A max 3 Phase AC 380V±10%, 20A max
AC220V(Option 110V)±10%, 50/60Hz
Dimension (DxWxH)
44x45x90cm
56x58x130cm
Gross Weight
About 90kg
About 150kg
30
Part 7 EMC and EMI Test System
LISUN GROUP
Ring Wave Generator (RWG61000-12)
Ring Wave Generator is the test equipment in conformity to IEC (the International Electro technical
Commission) standard IEC61000-4-12, EN61000-4-12, ANSI-C62-41 and GB/T17626.12. This
instrument is used for the simulative electrical network, the power supply of the reactive load and
the control line switch, as well as sensing the ring wave of the low voltage cables terminal equipment
caused by the disconnection of the power circuit, fault and insulation breakdown or lightning stroke.
The RWG61000-12 series products have LCD display in both English and Chinese.
Touch screen with super big LCD and built-in Windows CE
Specification:
Product Model
RWG61000-12
Output Voltage
RWG61000-12T
0~4KV
RWG61000-12A
RWG61000-12AT
0~6KV (Special Order)
Voltage/Current Wave
Open circuit voltage wave: frontier: 0.5μs±20%. Short circuit current wave:
frontier: ≤1μs. Oscillation frequency: 100kHz±10%
Polarity
Positive, Negative or Positive/Negative automatic
Phase Shift
Asynchronous, Synchronization 0°~360° or Specific Angle
Output Impedance
12Ω, 30Ω, 50Ω ± 20%
Coupling/Decoupling
Network (CDN)
Includes a 16A
single phase
Working Power
AC220V(Option 110V)±10%, 50/60Hz
Dimension (DxWxH)
44x45x35cm
Gross Weight
About 28kg
Includes a 20A
3phases/5wires
Includes a 16A
single phase
Includes a 20A
3phases/5wires
44x45x20cm
44x45x30cm
44x45x30cm
44x45x35cm(CDN) 44x45x20cm(CDN) 44x45x35cm(CDN)
About 46kg
About 45kg
About 48kg
Order Noted:
1. The RWG61000-12 can be assembly with SG61000-5 in one unit to down the cost
2. The 0~6KV Ring Wave Generator is special designed according to the customer request
31
Part 8 Electronic Ballast Tester
LISUN GROUP
Electronic Ballast Tester (WT5000)
WT5000 is the updated version of WT3000
with a super LCD for displaying waveforms
and parameters directly, and it includes all the
functions and technical parameters of WT3000.
Reports can be printed if printer is connected.
It also meets the latest requirements for
electronic ballasts in international standards
IEC 60929, IEC 60969, IEC 61000-3-2, GB/
T15144-2005, GB/T17263-1998 and so on.
Specification:
• WT5000 has expanding analysis for envelope wave
• WT5000 has Super LCD which can display the test report directly but no need to connect with PC
• Communicate the PC via RS-232, the English software can be run in WinXP, Win7 and Win8
• Accuracy for Voltage, Current and Power: ±(0.1% reading+0.1% range+1 word)
• Accuracy for Power Factor: ±(0.002+0.001/reading+1 word); Accuracy for Frequency: ±0.1% reading
• Accuracy for Harmonic (Virtual Value): ±(0.1% range+5% reading)
• Accuracy for Imported Cathodic current: ±(1% reading+1% range+2 word)
• Accuracy for Oscillation frequency: ±0.5% reading
• Input Parameters Measurement:
1) Test voltage, current, power, power factor, power net frequency, total harmonic and 0~39 harmonic.
2) Range of voltage and current basic wave frequency:45Hz~65Hz:
3) Range of voltage: 10.0~300.0V (virtual value); Range of power: NR: 0~450.0W; WR: 0~999.9W
4) Range of current: NR: 0.010~1.500A (virtual value); WR: 0.010- 4.500A (virtual value)
5) Range of power factor: 0.000~1.000
Output Stably Parameters Measurement:
1) Test lamp voltage, current, power, filament current, imported cathodic current, crest factor, oscillatory
frequency
2) Range of lamp voltage: 10.0~300.0V; Range of lamp power: NR:0.5~200.0W, WR:0.5~400.0W
3) Range of lamp current, filament current and imported cathodic current: NR:0.010~0.750A;WR:0.010~
1.500A
Output Startup Parameters Measurement:
1) Test preheats time and lamp voltage, current, filament current, changing curve and data of imported
cathodic current within 0 to 5s.
2) Range of lamp voltage: 10.0~800.0V; NR: 0.010~0.750A, WR: 0.010~1.500A
3) Range of lamp current, filament current and imported cathodic current:
Input & Output Measurement
Start Measurement
32
Preheat Measurement
Part 8 Electronic Ballast Tester
LISUN GROUP
Electronic Ballast Analyzer (WT3000)
WT3000 has all of the function, specification
and measurements as WT4000, but WT3000
hasn’t the super LCD screen. WT3000 has eight
windows to display each parameter of input
and output characteristics.
HID Ballast Tester (WT2000-HID)
WT2000-HID meets the latest requirements for electronic ballasts in international standards IEC 60929,
IEC 60969, IEC 61000-3-2, GB/T15144-2005, GB/T17263-1998 and so on.
Specification:
• Communicate the PC via RS-232, the English
software can be run in WinXP, Win7 and Win8
• Accuracy for Voltage, Current and Power:
±(0.4% reading + 0.1% range + 1 word)
• Accuracy for Power Factor: ±(0.004 + 0.001/
reading 1 word); Accuracy for Frequency:
±0.1% reading
• Accuracy for Lamp Voltage and Current: ±(1%
reading + 1% range +2 words)
• Accuracy for Lamp Power: ±2.5% range
• Accuracy for Oscillation frequency: ±0.5%
reading
Measurement:
• Input Parameters Measurement:
1) Test voltage, current, power, power factor, power line frequency, total harmonic and 0~50 harmonic
2) Range of voltage and current basic wave frequency: 45Hz~65Hz;
3) Range of narrow frequency: 45Hz~5kHz;
4) Range of wide frequency: 45Hz~1MHz;
Electronic Ballast Automatic Test Equipment (ATE-1)
Specification:
Test series connection, parallel connection and series/parallel connections of
the electronic ballast (about 15 kinds of connections), available for various
electronic ballast.
• With a precise resistance box, tube is substituted for the resistance, can
act as many as 6 tubes. Resistance value: 1~4095Ω adjustable.
• Measure input parameters (vrms, irms, W, PF, harmonics, etc), output
parameters (on-circuit voltage, lamp voltage, filament voltage, lamp current,
lamp power, oscillatory frequency), can also test the ballast efficiency,
abnormity protection, and power symmetry of partial rectifier effect and etc.
• Program controlled AC power source to guarantee the smart choice of
input voltage and the frequency.
• Equipped with 17 inch LCD controlled machine, specially designed A/D
combined with special CPU, has the two left and right testing interfaces to
achieve stability of data and high-speed testing.
• Communicate the PC via RS-232, the English softw are can be run in WinXP
or Win7
• We can make the special design product for you and promise to upgrade
the software for free.
33
Part 9 Electrical Safety Tester
LISUN GROUP
Glow-wire Test Apparatus (ZRS-3HS, ZRS-3H)
It is according to IEC60695-2-1, IEC60695-2-10~IEC60695-213(GB/T5169.10-2006~GB/T5169.13-2006), <basic testing methods of
Glow wire, basic testing methods of Glow wire device> and UL 746A,
IEC829, DIN695, VDE0471, the Glow wire tester ZRS-3H is suitable for
resistance to abnormal heat and fire test on lighting lamps, electronic
products and household appliances. Adopting high-temperature coating
spraying on steel structure and imported instrument display, with easy
operation, stable performance. The equipment is applicable to flame
resistance tests of all levels of QC departments and corresponding
enterprises.
Note: The ZRS-3HS Gross weight is 50kg and package size 80*70*50cm
ZRS-3HS Compact Version
Specification:
• Thermocouple diameter: 1mm K type, import insulated thermocouple
which can endure high
temperature, and it can endure about 1100℃ (superior to standard
1050℃)
• Heating temperature: adjustable continuously within the range of≤
500~1000℃, the accuracy of
temperature is 1℃, the resolution of temperature is ±3℃.
• Glowing time: 0.1~999.9s±0.1s (time range is adjustable).
• Burning time: 0.1~999.9s, auto record, manual pause.
• Flame chilling time: 0.1~999.9s, auto record, manual pause.
• Glow wire pressure on test specimen:0.95±0.1N. Limit pressure
depth is 7mm.
• Glow wire: 77%Ni/20±1%Cr and made in specific dimensions.
ZRS-3H Standard Version
Needle Flame Test (ZY-3S, ZY-3)
According to IEC60695-2-2 and IEC60695-11-5, ZY-3 Needle Flame
Test is applied in the production and quality control department of
lighting instrument, hyperpiesia electrical apparatus, domestic
appliance, machine electric appliance, electrical machine, power tool,
electronic instrument, electrician instrument and technical equipment.
Also, it is fit for the industry of insulation material, engineering
plastics and solid combustible material.
Note: The ZY-3S Gross weight is 50kg and package size 80*70*50cm
ZY-3S Compact Version
Specification:
Angle of burner: incline with 45°(when in test) / plumb(when adjust
the flame's height)
• Time of start burning: 0~999.9s±0.1s adjust (30s in general)
• Time of keep burning: 0~999.9s±0.1s, auto mark, pause with hand
• Height of frame: 12mm ± 1mm (test tool with height)
• Burning air: 95% of butagas
• Test range of temperature: 0~1000℃
• Requirement of flame's temperature: within 23.5 seconds±1s when
the temperature rises from 100℃±2℃ to 700℃±3℃
• Temperature testing thermocouple: Φ0.5mm K pattern thermocouple
ZY-3 Standard Version
34
Part 9 Electrical Safety Tester
LISUN GROUP
Horizontal Vertical Flame Tester (HVR-LSS, HVR-LS)
This equipment meets the requirements of ANSI/UL94, IEC60950-1, IEC6952-2 and GB. It is used to test the appliances and plastic materials parts of
electrical equipment for the horizontal, vertical flammability test. The product
tank shell is irony spray, and configured a transparent viewing window, the
digital meter shows the burning time, after flame time, afterglow time, this
device has beautiful appearance, is easy to use and has reliable performance.
Note: The HVR-LSS Gross weight is 50kg and package size 80*70*50cm
Specification:
• Burning Time: 0~999.9S(Adjustable), After flame Time: 0~999.9S
(Adjustable), After-blanch Time: 0~999.9S(Adjustable)
• Burning Angle: 0°, 20°, 45° and optional, Flame Height:
20mm~175mm (Adjustable)
• Gas Flow: 0.03~0.3ml/Min, Gas Pressure: 0~16Kpa pressure gauge
±200mm spout
• Burning Lamp: Internal tube diameter: 9.5±0.3mm,
Length:100mm±10mm
• Time Device: It can be accurate to 0.5S, Linear Measure: In millimeter
• Pressure Gauge: It can measure 0.2m water, taking 5mm as the
increment.
• Flow Meter: The maximum measurement accuracy is ±2%
• Position Adjustment: Sample clamp bracket can be up and down, left
and right controlled, combustion
HVR-LSS Compact Version
HVR-LS Standard Version
Hot Wire Ignition tester (RSY-LT)
.Hot wire ignition tester is according to the standard requirement of IEC60695-2-20 and GB4943, which
meets Standard Test Method for Ignition of Materials by Hot Wire Sources. It is suitable for electric and
electronic products, household appliance materials to do ignition dangerous test. It simulates the heat
source or ignition source of simulates glow component and overload resistance which may cause thermal
stress in a short time
Hot-wire coil ignition test adopts the specific size (Dia: 0.5mm; Length: 250mm) and specific material
(Ni80/Cr20) of heater strip which is pre-annealed with required heating power (0.26W/mm) and
specified time (8s~12s). Then coil heater strip on the specimen for 5 cycles according to certain wire
wrapping tension (5.4N) and certain wire wrapping distance (6.35mm). Then take the specimen with
wrapping heater strip to test until 120s under the stipulate heating power (0.26W/mm) the users can
judge the fire risk according to whether the specimen ignite and the ignite time.
Specification:
• It is according to IEC60695-2-20 and GB4943
• Heating coil: ф0.5mm, Ni80/Cr20, Length: 250mm±5mm , Cold
Resistance: 5.28Ω/m , Anneal holder. Distance: 250mm
• Specimen holder distance and height: 70mm, Height: 60mm (The
distance from stand surface to the connector plate surface)
• Wire wrapping tension and its distance: 5.4N±0.05N, 6.3mm±0.2mm
(within 31.5mm±0.5mm, coil 5 cycle, national standard is 6mm)
• Annealing time and power: 8s~12s (Digital display can be preset).
0.26W/mm±4%(Digital displayis adjustable)
• Testing time and power 120s ( 1s~999.9s Digital display can be
preset),0.26W/mm±4%(Digital display is adjustable)
• Specimen size:
L×W×H: (125±5)×(13.0±0.5)×(0.75+0.075)mm,1.5+0.150mm,3+0.3
0mm) national standard 0.75±0.1 mm, 1.5±0.1 mm, 3±0.2 mm
• Combustion box volume is bigger than 0.5 cubes(other size can
beoption)
35
Part 9 Electrical Safety Tester
LISUN GROUP
Tracking Test Chamber (TTC-1)
It is according to IEC60695 and IEC60112 (GB4207), the Tracking Test Chamber TTC-1 is intended for
determining the degree of protection against formation of conducting paths in solid insulating materials,
due to the electric stress and electrolytic contamination of the surface. This method simulates tracking
currents on insulation material by providing drops between electrodes. During the process of normal use,
insulating material may be exposed to moisture and dirt, if conductive, may cause stress and fire hazard.
Specification:
• It applied with rectangle size of platinum electrode,
each electrode can force to the sample is 1.0±0.05N
• The testing voltage is 100~600V (48~60Hz) which
can be adjustable
• When the short-circuit current in the 1.0±0.1A, the
voltage drops will be no more than 10%
• During the testing, the short-circuit current is more
than 0.5 A to keep 2 seconds, then shut off current,
it will show the sample not pass
• The liquid drop device can make the liquid height
from 30~40mm (adjustable), drops liquid size is 44
~55 drops/1cm3. The interval drops of liquid is 30S
±5S (adjustable)
• Inside dimension: 800x800x800mm and outside
dimension: 1120x520x1250mm (Special size can be
ordered as customer's request)
Temperature Meter for Lamp Caps & Luminaires Test (TMP-L)
TMP-L is according to IEC60360-1998 and GB2512-2001(Standard method of measurement of lamp cap
temperature rise). It is used to test the working and environmental temperature as well as temperaturerise of the burner and lamp. It meets the requirement of IEC and GB Standards
Specification:
• Channel sequence is displayed by 2 LED and temperature is
displayed by 4 LED; Simultaneously display temperature rise curve
• Sensor: K type thermocouple and 8 channels for input temperature
signal
• Temperature range: -40~300℃ and testing accuracy: Class 0.5
• Capable of circle monitoring, single monitoring, printing and RS-232
communication with PC
• Freely set up for channel sequence when circle monitoring
• Application software in Windows can track the changing of the
selected channel temperature and provide print and save operation
• Dimension of standard testing box: 90*90*90cm (inner box) and
105*105*120cm (outer box), or customized; Lamp holder: E14, E27,
E40, B22d and other holders
36
Part 9 Electrical Safety Tester
LISUN GROUP
Automatic Safety Test System (LS9934)
The LS9934/LS9935 Automatic Safety Test System is according to
GB4706.1, IEC/EN60335-1, UL60335, GB7000, IEC60598, GB4943,
IEC60950 and GB9706.1. It used for luminaries, home application
and motor tools safety test in production line or Lab R&D.
Specification:
• Display all setting parameters and testing results in the same big LCD menu
• It can set the PASS/FAIL limit value. It will have light/noisy to warning
• Includes the handle to do remote operate
• Test mode programmable; Quick discharge, 50 memory groups, 8 steps per group
• Support 50Hz and 60Hz frequency; Electric safety wall detecting feature
• The LS9934 can do test for Withstand Voltage (ACW), Insulation Resistance (IR), Leakage Current
(LLC) and Ground Resistance (GR)
• The LS9935 can test for Withstand Voltage (ACW), Insulation Resistance (IR), Leakage Current
(LLC), Ground Resistance (GR) and Power
Withstand Voltage Test (ACW)
Insulation Resistance Test (IR)
Voltage Range
Accuracy
Current Range
IR Range
AC100~5000V
±(1.5%+3V)
0.005~40.00mA
0.50~3000MΩ
Leakage Current Test (LLC)
LLC Range
0.005~20mA
Accuracy
Accuracy
Voltage Range
5%+0.5MΩ
DC100~1000V
Grounding Resistance Test (GR)
Voltage Range
±(1.5%+0.005mA) AC5.0~300.0V
GR Range
Accuracy
Output Current
0~600mΩ
±(1.5%+3mΩ)
AC3.00~30.00A
Power Test
Voltage
Current
Power
PF
Accuracy
Test Time
0~3000V
0~4.5A
2~1000W
0.2~1.000
Class 0.5
0~999.9s
Programmable Withstanding Voltage & Insulation Test (LS9922I)
The LS9922I is a high-performance testing device special for
withstanding voltage and insulation resistance test, allowing
setting the output voltage. The warning value, testing time
and some other parameters can be set in the software. It
with a variety of automatic test functions. The testing is
quick and high accuracy which is not only applied in the
production line but also in the lab develop research.
Output Voltage Range
Output Voltage Accuracy
Withstanding
Breakdown Current Range
Voltage
Insulation
Resistance
AC 0.3~5.00KV
±(2%+3bits)
0.10~10mA
Test time
0~999.9s
Output frequency
50Hz/60Hz
Output Voltage Range
DC 0.30~1.00KV
Output Voltage Accuracy
±(2%+3bits)
Insulation Resistance Range
1.0~1000MΩ
Insulation Resistance Accuracy
±(5% +3bits) <100 MΩ and ±(10% +5bits) >100 MΩ
Test time
0~999.9s
37
Part 9 Electrical Safety Tester
LISUN GROUP
AC/DC Withstand Voltage Test (WB2671A)
Specification:
•
•
•
•
Output voltage: 0~5kV (AC/DC);
Cutoff current range: AC 0~20/100mA; DC 0~20mA;
Test time: 1-60s;
Transformer capacity: 750VA.
Insulation Resistance Tester (WB2681A)
Specification:
• Insulation test voltages: DC250V, DC500V, DC1000V
• Range of open-circuit voltage: ±10% rated voltage
• Testing time: 3~99 seconds or controlled manually
Digital Oscilloscope (JC2202TA)
The JC Series Digital Oscilloscope was designed and produced by high accuracy electronic components
and modules. The test accuracy is world high class. It was used in all kinds of electronic products testing.
Specification:
• Mathematic functions
• 4k/Channel Memory depth
• Automatic setup of the menu
• Menu with multiple languages
• Digital Storage of the waveforms and setups
• Digital Storage Oscilloscope Use Manual
• Mono/Color LCD display 320*240 resolution
• Built-in FFT function digital filter, frequency
counter
• Trigger on edger, video, pulse width, external
and power
• Cursor measurements and automatic cursor
tracking measurements
• Delayed scan function, can display both the full
view and details of the waveforms
Model
Width
Sample Rate
Memory
Display
JC2202TA
200MHz
1GSa/s
4K
TFT
JC2152TA
150MHz
1GSa/s
4K
TFT
JC2102TA
100MHz
1GSa/s
4K
TFT
JC2062TA
60MHz
1GSa/s
4K
TFT
JC2102T
100MHz
500MSa/s
4K
TFT
JC2062T
60MHz
500MSa/s
4K
TFT
JC2042T
40MHz
500MSa/s
4K
TFT
JC2022T
25MHZ
500MSa/s
4K
TFT
38
Part 10 Environmental Test Chamber
LISUN GROUP
High & Low Temperature and Humidity Chamber (GDJS-015A, GDJW-010A)
It is according to IEC60068-2-1(GB/T2423.1) and IEC60068-2-2(GB/T2423.2). It is used to test the CFL/LED
which meets IES LM-80-08, electricity products, electronic components, material and so on.
Specification:
• The chamber is produced by SUS304 Steel, the temperature
keeping material is produced by Polyurethane hard foam and
ultra-fine fiber glass, the doorframe heat insulated by Double
high temperature aging silicone rubber door sealing strip.
• The temperature controller is used by Korean TEMI display in
English/Chinese and German Siemens PLC, it can be
communicated to PC via RS-232. The temperature accuracy is
0.1℃ and humidity is 0.1%R.H
• The temperature sensor is platinum PT100 Ohms/MV resistor
• The heating system is full separately system which produced
by Nickel chromium alloy electric heating type heater
• The cold system is applied by fully enclosed fan cooled single
-stage and cascade refrigeration mode, the compressor is from
France TECUMSEH brand which can allow you get after sales
support from many countries
• The cyclical system is applied by High temperature low noise
air conditioning type motor and Multi blade centrifugal wind wheel
• The safety self-protection function include Electric leakage,
short circuit, over temperature, motor overheating, compressor
pressure, overload, over-current protection
• Power: AC380V±10% 3phases and frequency 50Hz/60Hz
• Condition: Temperature is 5℃~+30℃ Humidity ≤85%R.H
High & Low Temperature and Humidity Chamber with Programmable Function (GDJS Series)
Model (cm)
GDJS-225*
GDJS-500*
GDJS-010*
GDJS-013*
GDJS-015*
Workroom Dimensions
50*60*75
70*80*90
100*100*100
100*100*130
100*100*150
Exterior Dimensions
105*102*200
132*132*217
167*152*231
217*152*231
245*160*231
Work Power
7.0kW
13.5kW
15.0kW
16.5kW
16.5kW
Temperature Range
A: -20℃~150℃
Humidity Range
30%~98% R.H
Fluctuation/Evenness
±0.5℃/±2℃
Humidity Deviation
-2%~-3% R.H
B: -40℃~150℃
C: -60℃~150℃
Temperature Rise Speed 1.0~3.0℃/min
Temperature Fall Speed
0.7~1.0℃/min
High and Low Temperature Chamber with Programmable Function (GDJW Series)
Working Room Size
GDJW-225*
GDJW-500*
GDJW-010*
Workroom Dimensions (cm)
50x60x75
70x80x90
100x100x100 100x100x130
Temperature Range
A: -20℃~150℃
Fluctuation/Evenness
±0.5℃/±2℃
Temperature Rise Speed
1.0℃~3.0℃/min
Temperature Down Speed
0.7℃~1.0℃/min
B: -40℃~150℃
GDJW-013*
GDJW-015*
100x100x150
C: -60℃~150℃
The * in GDJS-225* means the temperature range A: -20℃~150℃, B: -40℃~150℃, C: -60℃~150℃
39
Part 10 Environmental Test Chamber
LISUN GROUP
Waterproof Test (JL-X)
JL-X waterproof test system is according to IEC60529,
IEC60598, IEC60335 and IEC 60034-5:2000. The JL-X
includes the following test grades: IPX1, IPX2, IPX3,
IPX4, IPX5, IPX6, IPX7 and IPX8 (Refer to page 51 of
IEC60529). It is widely used in the authentication test
organization for the products such as electrical &
electronic products such as LED luminaires as well as
in the relevant quality control department for the
waterproof detection of the enclosures protection
grades.
The whole JL-X waterproof test system includes:
• Drip Box (JL-12): The drip box is for IPX1 and IPX2 drip test. The drip box size is 800x800x75mm
(LxWxH). The diameter of drip hole is 0.4mm, distant of drip hole is 20mm, sample can be over 150kg
• Swing Pipe Water Spray Test Equipment (JL-34): It is for IPX3 and IPX4 test, the semi-diameter of swing
pipe is 1meter. IPX3 is 120degree and IPX4 is 180degree. The diameter of inside swing pipe is 0.4mm.
The automatic sample rotating base diameter is 600mm and speed is 1~5rpm which controlled by PLC panel
• Waterproof Jet Test Device (JL-56): With water supply device size is 1000x1000x600mm, the bore diameter
is ф6.3mm (IPX5) and ф12.5mm (IPX6). Diameter of hole is 6.3mm for IPX5 and 12.5mm for IPX6. The
water speed is 12.5±0.626L/min for IPX55 and 100±5L/min for IPX6.
• Immersion tank Waterproof test Device (JL-7): It is for IPX7 test. The top of the water tank size is 1000
x1000x1200mm. The sample testing base is max 120kg. It includes two temperature channels meter and
digital display.
• Immersion tank Waterproof test Device (JL-8): It is for IPX8 test. It can measure 0~50m water depth.
The water immersion size is diameter is 600mm and height is 1200mm, the compressive stress is 10
atmospheric pressures or design customer request
40
Part 10 Environmental Test Chamber
LISUN GROUP
High Temperature & Pressure Jet Waterproof Test Chamber (JL-9K1L)
JL-9K1L High Temperature & Pressure Jet Waterproof Test Chamber is
according to IEC60529, GB4208, DIN40050-9 and ISO20653 for
protection level IPX9K testing. It is a waterproof test machine designed
for vehicle spare parts, electrical and electronic industry, to simulate
natural environment or human factors.
The both interior and exterior material of this chamber is high quality
stainless steel, big glass observation window and elegant appearance.
The turntable and spray lance motor adopt imported motor, rotation speed
can be adjusted according to requirement. .
Specification:
•
•
•
•
•
•
•
•
•
•
Working Chamber: 1000*1000*1000mm
Test time: 30s (Pre-settable and adjustable)
Angle of Water Ring: 0°, 30°, 60°,90°(The testing angle can be adjusted)
Number of blowhole: 4. Testing table: Load bearing 15kg/Φ400~500mm
Based on horizontal line, distribute nozzle hole at anticlockwise±0°±30°±60°±90°with valve on nozzle
Water Temperature in Tank: 80±5°(Adjustable, enhanced temperature and water overflow protection)
Spraying distance:100mm~200mm and can be adjustable nozzle distance by manual
Spraying pressure: 8000~10000kPa (81.5~101.9kg/cm2)
Electrical high temperature flow meter: Flow is 14~16 L/min
Rotation speed of testing table: 5~17r/min (Motor drives turbine slow rotating, control speed and
adjust to appropriate speed by frequency converter)
Aging and Life Test Rack (SY2036)
Specification:
Power supply: 220V AC/50Hz or 120V AC/60Hz
Lamp type: E27 or any other lamp holder, T5/T8/T12 tubes or HID/LED street luminaires.
Lamps holder positions: E27 lamp holder 168pcs or can be design option
Hierarchy number: A total of 3 layers, three groups of independent control.
ON/Off life cycle test: it can be set the lamp ON time or Off time by PLC, then can read the total
aging life in the big display screen.
• Test number: 0~99999 presentable and adjustable
• The voltage of each layer independent display
• Other type lamps being tested: By transforming lamps holder to make test.
•
•
•
•
•
The aging rack can be special designed according customer’s request
41
Part 10 Environmental Test Chamber
LISUN GROUP
Dustproof Testing Machine (SC-015)
The Dustproof Test Chamber SC-015 is according to IEC60529, GB2423.37-89 (Test L: dust test methods),
GB 4208-93 protective casing grade (IP code), GB/T 4942.2-93(protective casing grade of low-voltage
apparatus), GB 7000.1-1996, GB 7001-1986(protective casing grade of lamps), DIN40050 and IP5K0. The
SC-015 is applied in LED or other luminaries for IP5X and IP6X test
Specification:
•
•
•
•
•
•
•
Temperature Range: environmental temperature +5~50℃ (Adjustable)
Humidity Range: 45%~75% (Adjustable)
Metal net standard nominal line diameter: 50μm
Environmental air pressure: 85Kpa~106Kpa
Airflow velocity in the chamber: 1.5m/s (adjustable range 0~4.99m/s)
Test dust: dry talcum powder, portland cement, smoke ash and etc.
Line spacing between the standard: 32μm, 75μm and 250μm (There are
three Metal nets)
• Selecting dust concentration control instrument: get sample through the
optical principle, show the dust concentration and automatic control
powder quantity that entering into the Cabinet according to the
concentration of the set: (needed cleaning compressed air source
configuration, require the pressure: 1~3kg/cm3)
• Power supply: 380V 3phases 50Hz/60Hz
Model Number
Working Room Size (mm)
SC-500
600*700*800
SC-800
800*800*800
SC-010
1000*1000*1000
SC-015
1000*1500*1000
SC-020
1000*2000*1000
Remark
Single door structure
Cabinet can be put in a horizontal direct or vertical direct
IK Level Tester (IK07-10)
The most of luminaires manufactories were requested to do IK
level test (Impact Protection). LISUN can supply the IK test
instrument include IK01-06 and IK07-10.
IK07-10 Impact Pendulum
IK ratings are defined as IKXX, where “XX” is a number from
00 to 10 indicating the degrees of protection provided by
enclosures (including luminaires) against external mechanical
impacts. The different IK ratings relate to the ability of an
enclosure to resist impact energy levels measured in joules (J).
IEC 62262 specifies how the enclosure must be mounted for
testing, the atmospheric conditions required, the quantity and
distribution of the test impacts and the impact hammer to
be used for each level of IK rating. The IK application on lighting
luminaires testing is according to IEC60598 (GB7000) and
IEC60068-2-75 (GB2423.55).
Degrees of protection against external mechanical impacts:
IK01
IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10
0.14J 0.2J
0.35J 0.5J
0.7J 1J
2J
5J
10J
42
20J
IK01-06 Spring Impact Hammber
Part 10 Environmental Test Chamber
LISUN GROUP
Salt Spray Test Machine (YWX/Q-010)
The Salt Spray Test Machine/Chamber is applicable to the salt spray corrosive test for the protection layer
of components, parts, electronic and electrical parts and metal materials and industrial products.
Specification:
• The Salt Spray Test Machine is made of transparent
materials so that the operator can see the tested sample
in it and the spraying situation of the tested sample.
• A waterproof structure is adopted between the chamber
cover and chamber body, thus there is no salt spray
overflow.
• It meets the following standards: IEC60068-2-11(GB/
T2423.17), GB/T10125, ISO9227, ASTM-B117, GB/
T2423-18, IEC 60068-2-52, ASTM-B368, MIL-STD-202,
E I A- 3 6 4 - 2 6 , A S T M - B 1 1 7 , GJB150, DIN50021-75,
ISO3768, 3769, 3770; CNS 3627, 3885, 4159, 7669 etc.
Model
Work Room Size (mm)
Exterior Size (mm)
Voltage
Power (kW)
YWX/Q-150
590*470*400
1070*800*1050
1Phase/220V
2.5
YWX/Q-250
1000*640*500
1400*870*1150
1Phase/220V
3.5
YWX/Q-750
1100*750*500
1680*1030*1260
1Phase/220V
4.5
YWX/Q-010
1300*1000*600
2000*1160*1390
3Phase/380V
6.5
YWX/Q-016
1600*900*720
2320*1280*1500
3Phase/380V
9.5
YWX/Q-020
2000*1000*800
2530*1220*1410
3Phase/380V
11
Electrodynamic Vibration Generator System (LVD-100KG)
Electrodynamic Vibration Generator System is complied
with IEC 60068, IEC68-2-6, JJG189-97, GB/T13309-91,
GB2423 etc. Full-function computer control, it includes
computer and printer, connect computer to do control,
store, record and print function.
Specification:
• Function: Sine Wave, Frequency Modulation, Sweep Frequency, Programmable, Frequency Doubling,
Logarithm, High Acceleration speed, Amplitude Modulation, Time Control, Full-function Computer
Control, simple and easy to set the acceleration and amplitude.
• Vibration table size(cm): L*H*W(Vertical table 50×20×50; horizontal table 50×25×50)
• Maximum test load Capacity: 100KG
• Frequency Modulation function: any frequency must be in the frequency range (maximum acceleration
speed< 20 g; maximum amplitude < 5 mm)
• Sweep Frequency function (0.01 Hz): (Upper frequency, Lower frequency, Time range) It can set real
standard arbitrarily to sweep frequency back and forth.
• Programmable Function (0.01Hz): It can set each segment in 15 segments arbitrarily
(frequency/amplitude/time/acceleration), and it can be recycled.
• Frequency doubling function (0.01 Hz): 15 segments multiplied-increase: 1. Low to high frequency;
2. High to low frequency; 3. Low to high and then to low frequency, it can be recycled.
• Logarithmic function (0.01 Hz), 3 modes of logarithm/can be recycled:
A. Lower to upper frequency
B. Upper to lower frequency
C. Lower to upper and then to lower frequency
43
Part 11 AC and DC Power Supply
LISUN GROUP
Digital CC and CV DC Power Supply (DC3005)
Specification:
The DC Series Power Supplies are with high
stability and high accuracy. The voltage and
current can be adjustable and simple operation.
They are suitable to supply DC Power for the
standard lamp and the large power LED. Other
voltage and current DC Power Supply can be
designed according to customer's request.
DC3010
DC6005
Model
DC3005
DC6010
DC12010
Output Voltage Range
Output Current Range
0.005~30.00V 0.005~30.00V 0.005~60.00V 0.005~60.00V 0.0010~120V
0.005~5.000A 0.005~10.00A 0.005~5.000A 0.005~10.00A 0.005~10.00A
Voltage
0~30V, 0~60V or 0~120V
Resolution of Voltmeter
0.0001V(0.1V~10.000V) 0.001V(10.000V~60.000V)
Accuracy of Voltage and
Current
+/-(0.02% Reading + 0.01% Range +1 Digit)
Stability of Output Voltage
+/-0.01% Reading/3min
Stability of Output Current
+/-0.01% Reading/3min
AC Power Source (LSP-500VAR)
Specification:
•
•
•
•
•
•
•
•
•
•
•
•
AC-DC-AC frequency conversion technology
Output frequency range: 45.00~65.00Hz
Output voltage range: AC 0.0~300.0V
Zero output impedance, equivalent resistance ≤0.1
Insulation for power output to make test safely and steady
Protection for over hot and thundering voltage and current
Input by keyboard, big/small adjustment, fast parameter set-up
Total voltage distortion: ≤0.6%; Voltage stability: ≤0.1%/30 min
Load adjust rate: ≤0.1%; Frequency stability: ≤0.05%/30min
Digital wave synthesis, wave feed-back technology, low power distortion
Controlled and tested by 16 bits MCU, which has high automation
High speed 12 bits A/D sampling technology, exactly display Voltage,
Current, Power, Power factor, Frequency
Output Power
Remark
500W
0~150V: 4.2A, 150~300V: 2.1A
(LSP-500VAR has R-232 port can communicate with
PC with low harmonic and high accuracy)
LSP-1KVAR
1000W
0~150V: 8.4A, 150~300V: 4.2A
(LSP-1KVAR has R-232 port can communicate with
PC with low harmonic and high accuracy)
LSP-2KVA
2000W
0~150V: 16.8A, 150~300V: 8.4A
Model
LSP-500VA
LSP-500VAR
LSP-1KVA
44
Part 11 AC and DC Power Supply
LISUN GROUP
PWM Type AC Power Supply (LSP-5KVA)
Specification:
• Circuit Type: (IGBT) MPWM Pulse Duration Modulation
• Input: 1 Phase 220V±10%, 50Hz/60Hz±5%
• Output Voltage: HIGH/LOW Adjustable
1) 1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V
2) Nominal Voltage: +10%~+25%, -10%~-30%
• Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz
• Load Voltage Stabilization Rate: ≦0.5%
• Frequency Stabilization Rate: 0.1% (Fix Point 50Hz, 60Hz and 400Hz)
• Wave Distortion Rate: ≦2% (Resistor Load); Efficiency:≧85%
• Output Instruments: Frequency Indicator, 4-digits RMS
digital frequency indicator, resolution is 0.1Hz Voltage Meter,
4-digits RMS digital voltage meter, resolution 0.1V Ampere
Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power
indicator, resolution 1W Power Factor Meter Resolution 0.001
• Protective Devices: Over load, short circuit, over voltage, over current, over temperature protective
with alarm
• Operating Environment: Temperature 0~40℃.Relative Humidity:0~90%
Model
Output Power
Specification
LSP-3KVA
3000W
0~150V: 25A, 150~300V: 12.5A
LSP-5KVA
5000W
0~150V: 42A, 150~300V: 21A
PS. More than 5KVA AC Power Source can be designed as customer’s request
Digital Power Meter (LS2008R, LS2010, LS2012, LS2050)
• Measure Voltage, Current, Power and Power Factor
• Voltage range: 10~600V; Current range: 0.005~20A
• Accuracy: ± (0.4%reading + 0.1%range + 1digit). LS2050: ±(0.1%reading+0.1%range+1digit)
• Communicate with PC by RS-232. It can communicate with LISUN other instruments such as LMS-5000,
LMS-8000 and LMS-9000
Model
Measure
Remark
LS2008R AC Parameters: U, I, P, PF
AC model
LS2010
AC Parameters: U, I, P, PF and harmonic
Special Software can show harmonic in Win7 or Win8
LS2012
AC+DC Parameters: U, I, P, PF
DC: 1~600V, DC Current Range: 0.005~20A (small
current 0.005~2A optional), out of limit alarming
LS2050
AC+DC Parameters: U, I, P, PF
and harmonic
High accuracy with Special Software can show
harmonic in Win7 or Win8, out of limit alarming
LS2010 Harmonic Model
LS2012 AC&DC Model
45
LS2050 High Accuracy Model
Part 12 Electronic Component Test
LISUN GROUP
Magnetic Material Analyzer (UI9730)
Specification:
• Parameters to be measured (absolute value): Measure hypoclass U, Iout, Hz, Hc, Br, Bm, Hm, Br/Bm, μm, magnetic core
loss, B-H curve, U curve and I curve
• Output capacity of the high frequency power: Uout: 1~300V,
Iout: 0.05~5A, Pout: 300VA, frequency: 10~300kHz
• Accuracy: 2%
• With 12-bit high-speed A/D, sampling rate up to 40MHz,
ensuring data precise and stable test result
• Super maximal database, suitable for almost all kinds of
magnetic material in market such as: Circle, E, U, ETD-EER,
JAR, RM, EP, PM, EL, ER, PQ, EFD, Plane E and etc
• Perfect software interface enables observation of curve in
detail
• Meet international test requirements for magnetic particle
ASTM E1444, ASTM E709-08.
DC Bias Current Source (FD1772B)
Specification:
•
•
•
•
•
Constant DC output 0~6A
Auto or manual current sweep output
5 current range output
Output voltage range: 0~11.5V
Current accuracy: ±(1%reading+2digit)
LCR Digital Bridge (FD2810B)
Specification:
•
•
•
•
•
•
•
•
Test parameter: C, R, L, Z, D, Q
Test frequency: 100Hz, 120Hz, 1kHz, 10kHz
Test level range: 0.1V, 0.3V, 1.0V
Output impedance: 30Ω, 100Ω
Slow or fast (15 times/s)
Automatic selecting, out of limit alarming
Provide the RS-232 & HANDLER interface
Accuracy: 0.1%
Electrolytic Capacitor Meter (HF2686C)
Specification:
•
•
•
•
•
Test voltage: 0~200V/0~500V
Output current range: 0.1μA~30mA
Maximum charge current: 200mA±10%
Charge time: 0.5s/1s/2s/3s/4s/5s/7s/10s/30s/60s
Accuracy: ±2%
46
Lisun Electronics lnc.
Http://www.Lisungroup.com
LISUN GROUP
Application
LED Luminaires and LED Power Driver Test Solution
Goniophotometer System: LSG-3000, LSG-1800B or LSG-1700B
Spectroradiometer & Integrating Sphere Test System: LPCE-2
LED Life Maintains Test System according to LM-80: LEDLM-80PL
Waterproof Test for IPX5 and IPX6 level testing: JL-56
Dustproof Testing Machine for IP5X and IP6X level testing: SC-015
LED Driver Testers: WT2080 (for LAB) and LSLED-12 (for production line)
Electricity Safety Tester: LS9934, ZRS-3HS, ZY-3S
Single LEDs or LED Chips
CFL and Electronic Ballast Test Solution
Goniophotometer System: LSG-1800B or LSG-1700B
Integrating sphere and Spectrophotometer Test System: LPCE-1
Adjustable Reference Ballast: DYJ-50HZ, HCS-105A and DYJ-HID
Electric Ballast Tester: WT5000 (for LAB) and ATE-1 (for production line)
Digital Torsion Meter and Multiway Life Tester: CH338 and CH316
Electricity Safety Tester: LS9922I, ZRS-3HS, ZY-3S
EMC and EMI Test Solution for CFL and LED Luminaires
EMI Test System: KH3962 or KH3961
Electrostatic Discharge Simulator: ESD61000-2
EFT Immunity Measurement: EFT61000-4
Surge Generator: SG61000-5
Voltage Dips and Interruptions Generator: CSS61000-11
Ring Wave Generator: RWG61000-12
LED Luminaires
LED Power Driver
Certificate & Awards
CIE Supportive Membership
CE-EMC Certificate
CE-LVD Certificate
ISO9001:2008
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising