Transmitters: Honeywell ST 3000 Smart Transmitter Series 100

Transmitters: Honeywell ST 3000 Smart Transmitter Series 100
ST 3000 Smart Transmitter
Series 100 Remote Diaphragm Seals Models
STR12D
STR13D
STR14G
STR17G
STR14A
0-10 to 0-400 inH2O
0-5 to 0-100 psid
0-5 to 0-500 psig
0-100 to 0-3000 psig
0-5 to 0-500 psia
0-25 to 0-1000 mbar
0-0.35 to 0-7 bar
0-0.35 to 0-35 bar
0-7 to 0-210 bar
0-0.35 to 0-35 bar
34-ST-03-64
7/04
Specification and
Model Selection
Guide
Introduction
In 1983, Honeywell introduced the first
Smart Pressure Transmitter― the ST
3000®. In 1989, Honeywell launched
the first all digital, bi-directional protocol
for smart field devices. Today, its ST
3000 Series 100 Remote Seal
Transmitters continue to bring proven
“smart” technology to a wide spectrum
of measurement applications. Typical
applications include high accuracy level
measurement in pressurized vessels in
the chemical and hydrocarbon
processing industries. A second
application consists of accurate flow
measurement for slurries and high
viscosity fluids in the chemical industry.
Honeywell remote seal transmitters
demonstrate proven reliability in
hundreds on installations in a wide
variety of industries and applications
with a wide variety of secondary fill
fluids for corrosive or high temperature
process fluids.
All ST 3000 transmitters can provide a
4-20 mA output, Honeywell Digitally
Enhanced (DE) output, HART* output,
or FOUNDATION™ Fieldbus output.
When digitally integrated with
Honeywell’s Process Knowledge
System™, EXPERION PKS™,
ST 3000 instruments provide a more
accurate process variable as well as
advanced diagnostics.
Honeywell’s high-performance ST 3000
S100 transmitters lead the industry in:
• Accuracy
• Stability
• Reliability
• Rangeability
• Warranty
Includes Lifetime Tranmsitters:
• Accuracy = +/-0.0375%
• Stability = +/-0.01% per year
• Reliability = 470 years MTBF
• Rangeability = 400 to 1
• Lifetime Warranty = 15 years
Figure 1—Series 100 Remote Seal Pressure Transmitters feature proven
piezoresistive sensor technology.
The devices provide comprehensive self-diagnostics to help users
maintain high uptime, meet regulatory requirements, and attain high
quality standards. S100 transmitters are ideal for critical applications,
such as custody transfer of natural gas and energy and material
balances, where accuracy and stability are of the utmost importance.
"Our commitment to Honeywell field instruments is based on
seamless integration with our Honeywell system and the enhanced
fault detection that the Honeywell DE protocol offers. Honeywell
instruments also offer us a better way of ensuring database integrity
over simple analog instruments. In addition, Honeywell's high-quality
support has enabled us to better implement solutions to some of our
more difficult problems. We have used Honeywell differential pressure
smart transmitters for the past eight years. Based on their accuracy
and low failure rates, we are now targeting critical flow applications
that require the robustness that these transmitters bring.”
DCS Systems Engineer
International Integrated Oil Company
34-ST-03-64
Page 2
Description
The ST 3000 transmitter can replace any 4 to 20 mA output transmitter in
use today and operates over a standard two-wire system.
The measuring means is a piezoresistive sensor, which actually contains
three sensors in one. It contains a differential pressure sensor, a
temperature sensor, and a static pressure sensor.
Features
•
Choice of linear or square
root output conformity is a
simple configuration selection.
•
Direct digital integration with
Experion PKS and other
control systems provides local
measurement accuracy to the
system level without adding
typical A/D and D/A converter
inaccuracies.
•
Unique piezoresistive sensor
automatically compensates
input for temperature and
static pressure.Added “smart”
features include configuring
lower and upper range
values, simulating accurate
analog output, and selecting
preprogrammed engineering
units for display.
•
Smart transmitter capabilities
with local or remote
interfacing means significant
manpower efficiency
improvements in
commissioning, start-up, and
ongoing maintenance
functions.
Microprocessor-based electronics provide higher span-turndown ratio,
improved temperature and pressure compensation, and improved
accuracy.
The transmitter’s meter body and electronics housing resist shock,
vibration, corrosion, and moisture. The electronics housing contains a
compartment for the single-board electronics, which is isolated from an
integral junction box. The single-board electronics is replaceable and
interchangeable with any other ST 3000 Series 100 or Series 900 model
transmitter.
Like other Honeywell transmitters, the ST 3000 features two-way
communication between the operator and the transmitter through our
Smart Field Configurator (SFC). You can connect the SFC anywhere that
you can access the transmitter signal lines.
The SCT 3000 Smartline® Configuration Toolkit provides an easy way to
configure instruments using a personal computer. The toolkit enables
configuration of devices before shipping or installation. The SCT 3000 can
operate in the offline mode to configure an unlimited number of devices.
The database can then be loaded downline during commissioning.
34-ST-03-64
Page 3
Specifications
Operating Conditions – All Models
Parameter
Reference Condition
Ambient Temperature *
Humidity
% RH
Maximum Allowable
Working Pressure (MAWP)
Supply Voltage, Current,
and Load Resistance
Operative Limits
°C
°F
°C
°F
°C
°F
25 ±1
77 ±2
—
—
—
—
10 to 55
0 to 100
0 to 100
Transportation and
Storage
°C
°F
–55 to 90 –67 to 194
0 to 100
MAWP is minimum of Body Rating or Seal Rating (See Model Selection Guide for Seal
MAWP)
Body
STR12D
STR13D
STR14G
STR17G
STR14A
Vacuum Region - Minimum
Pressure
mmHg absolute
Rated Condition
MAWP
2500 psig (172 bar)
2500psig (172 bar)
500 psig (35 bar)
3000psig (207 bar)
500 psia (35 bar).
Atmospheric (See Figure 4 for vacuum limitations.)
Voltage Range:
Current Range:
Load Resistance:
10.8 to 42.4 Vdc at terminals
3.0 to 21.8 mA
0 to 1440 ohms (as shown in Figure 5)
* Ambient Temperature Limit is a function of Process Interface Temperature. (See Figure 2.)
34-ST-03-64
Page 4
Performance Under Rated Conditions * - Model STR12D (0-10 to 0-400 inH2O)
Parameter
Description
Upper Range Limit **
inH2O
mbar
400 (39.2°F/4°C is standard reference temperature for inH2O range.)
1000
Minimum Span
inH2O
mbar
10 Note: Recommended minimum span in square root mode is 20 inH2O (50 mbar).
25
Turndown Ratio
40 to 1
Zero Elevation and Suppression
No limit except minimum span within ±100% URL.
Accuracy (Reference – Includes
combined effects of linearity,
hysteresis, and repeatability)
In Analog Mode: ±0.2% of calibrated span or upper range value (URV), whichever is
greater, terminal based.
• Accuracy includes residual error
after averaging successive
readings.
50 inH2O
±0.1 + 0.1  span inH O or ±0.1 + 0.1
2 

• For FOUNDATION Fieldbus use
Digital Mode specifications. For
HART use Analog Mode
specifications.
In Digital Mode: ±0.175% of calibrated span or upper range value (URV), whichever is
greater, terminal based.
Combined Zero and Span
Temperature Effect per 28°C
(50°F) ***
In Analog Mode: ±1.2% of span.
For URV below reference point (50 inH2O), accuracy equals:
125 mbar
( span
mbar) in % span
For URV below reference point (50 inH2O), accuracy equals:
50 inH2O
±0.075 + 0.10  span inH O or ±0.075 + 0.10
2 

125 mbar
( span
mbar) in % span
For URV below reference point (100 inH2O), effect equals:
100 inH2O
±0.2 + 1.0  span inH O or ±0.2 + 1.0
2 

250 mbar
( span
mbar) in % span
In Digital Mode: ±1.175% of span.
For URV below reference point (100 inH2O), effect equals:
100 inH2O
±0.175 + 1.0  span inH O or ±0.175 + 1.0
2 

250 mbar
( span
mbar) in % span
* Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and
316L Stainless Steel barrier diaphragm.
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.
*** Apply 1.5 times factor to capillary lengths greater than 10 feet.
34-ST-03-64
Page 5
Performance Under Rated Conditions * - Model STR13D (0-5 to 0-100 psid)
Parameter
Description
Upper Range Limit **
psid
bar
100
7
Minimum Span
psid
bar
5
0.35
Turndown Ratio
20 to 1
Zero Elevation and Suppression
No limit except minimum span within –18% and +100% of URL. Specifications valid from
–5% to 100% of URL.
Accuracy (Reference – Includes
combined effects of linearity,
hysteresis, and repeatability)
In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is
greater, terminal based.
• Stated accuracy does not apply
for models with 2.9 inch
diameter remote seal
diaphragms.
• Accuracy includes residual error
after averaging successive
readings.
• For FOUNDATION Fieldbus use
Digital Mode specifications. For
HART use Analog Mode
specifications.
Combined Zero and Span
Temperature Effect per 28°C
(50°F) ***
For URV below reference point (30 psi), accuracy equals:
±0.05 + 0.05
30 psi
2 bar
( span
psi) or ±0.05 + 0.05 ( span bar) in % span
In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is
greater, terminal based.
For URV below reference point (30 psi), accuracy equals:
±0.025 + 0.05
30 psi
2 bar
( span
psi) or ±0.025 + 0.05 ( span bar) in % span
In Analog Mode: ±0.33% of span.
For URV below reference point (30 psi), effect equals:
±0.05 + 0.28
30 psi
2 bar
( span
psi) or ±0.05 + 0.28 ( span bar) in % span
In Digital Mode: ±0.305% of span.
For URV below reference point (30 psi), effect equals:
±0.025 + 0.28
*
30 psi
2 bar
( span
psi) or ±0.025 + 0.28 ( span bar) in % span
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and
316L Stainless Steel barrier diaphragm.
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.
*** Apply 1.5 times factor to capillary lengths greater than 10 feet.
34-ST-03-64
Page 6
Performance Under Rated Conditions * - Model STR14G (0-5 to 0-500 psig)
Parameter
Description
Upper Range Limit **
psig
bar
500
35
Minimum Span
psig
bar
5
0.35
Turndown Ratio
100 to 1
Zero Elevation and Suppression
No limit except minimum span from absolute zero to 100% of URL. Specifications valid
over this range.
Accuracy (Reference – Includes
combined effects of linearity,
hysteresis, and repeatability)
In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is
greater.
• Accuracy includes residual error
after averaging successive
readings.
• For FOUNDATION Fieldbus use
Digital Mode specifications. For
HART use Analog Mode
specifications.
Combined Zero and Span
Temperature Effect per 28°C
(50°F) ***
For URV below reference point (20 psi), accuracy equals:
±0.05 + 0.05
20 psi
1.4 bar
( span
psi) or ±0.05 + 0.05 ( span bar) in % span
In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is
greater.
For URV below reference point (20 psi), accuracy equals:
±0.025 + 0.05
20 psi
1.4 bar
( span
psi) or ±0.025 + 0.05 ( span bar) in % span
In Analog Mode: ±1.88% of span.
For URV below reference point (75 psi), effect equals:
±0.2 + 1.68
75 psi
5.25 bar
( span
psi) or ±0.2 + 1.68 ( span bar) in % span
In Digital Mode: ±1.855% of span
For URV below reference point (75 psi), effect equals:
±0.175 + 1.68
*
75 psi
5.25 bar
( span
psi) or ±0.175 + 1.68 ( span bar) in % span
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and
316L Stainless Steel barrier diaphragm.
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.
*** Apply 1.5 times factor to capillary lengths greater than 10 feet.
34-ST-03-64
Page 7
Performance Under Rated Conditions * - Model STR17G (0-100 to 0-3000 psig)
Parameter
Description
Upper Range Limit **
psig
bar
3000
210
Minimum Span
psig
bar
100
7
Turndown Ratio
30 to 1
Zero Elevation and Suppression
No limit except minimum span from absolute zero to 100% of URL. Specifications valid
over this range.
Accuracy (Reference – Includes
combined effects of linearity,
hysteresis, and repeatability)
In Analog Mode: ±0.15% of calibrated span or upper range value (URV), whichever is
greater.
• Accuracy includes residual error
after averaging successive
readings.
• For FOUNDATION Fieldbus use
Digital Mode specifications. For
HART use Analog Mode
specifications.
Combined Zero and Span
Temperature Effect per 28°C
(50°F) ***
For URV below reference point (300 psi), accuracy equals:
±0.10 + 0.05
300 psi
21 bar
( span
psi) or ±0.10 + 0.05 ( span bar) in % span
In Digital Mode: ±0.125% of calibrated span or upper range value (URV), whichever is
greater.
For URV below reference point (300 psi), accuracy equals:
±0.075 + 0.05
300 psi
21 bar
( span
psi) or ±0.075 + 0.05 ( span bar) in % span
In Analog Mode: ±0.70% of span.
For URV below reference point (500 psi), effect equals:
±0.20 + 0.50
500 psi
34.5 bar
( span
psi) or ±0.2 + 0.50 ( span bar) in % span
In Digital Mode: ±0.675% of span.
For URV below reference point (500 psi), effect equals:
±0.175 + 0.50
*
500 psi
34.5 bar
( span
psi) or ±0.175 + 0.50 ( span bar) in % span
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and
316L Stainless Steel barrier diaphragm.
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.
*** Apply 1.5 times factor to capillary lengths greater than 10 feet.
34-ST-03-64
Page 8
Performance Under Rated Conditions * - Model STR14A (0-5 to 0-500 psia)
Parameter
Description
Upper Range Limit **
psia
bar absolute
500
35
Minimum Span
5
0.35
psia
bar absolute
Turndown Ratio
100 to 1
Zero Elevation and Suppression
No limit except minimum span from 0 to 100% URL.
Accuracy (Reference – Includes
combined effects of linearity,
hysteresis, and repeatability)
In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is
greater.
• Accuracy includes residual error
after averaging successive
readings.
• For FOUNDATION Fieldbus use
Digital Mode specifications. For
HART use Analog Mode
specifications.
Combined Zero and Span
Temperature Effect per 28°C
(50°F) ***
For URV below reference point (20 psi), accuracy equals:
±0.05 + 0.05
20 psi
1.4 bar
( span
psi) or ±0.05 + 0.05 ( span bar) in % span
In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is
greater.
For URV below reference point (20 psi), accuracy equals:
±0.025 + 0.05
20 psi
1.4 bar
( span
psi) or ±0.025 + 0.05 ( span bar) in % span
In Analog Mode: ±1.88% of span.
For URV below reference point (50 psi), effect equals:
±0.2 + 1.68
50 psi
3.5 bar
( span
psi) or ±0.2 + 1.68 ( span bar) in % span
In Digital Mode: ±1.855% of span
For URV below reference point (50 psi), effect equals:
±0.175 + 1.68
*
50 psi
3.5 bar
( span
psi) or ±0.175 + 1.68 ( span bar) in % span
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and
316L Stainless Steel barrier diaphragm.
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.
*** Apply 1.5 times factor to capillary lengths greater than 10 feet.
34-ST-03-64
Page 9
Performance Under Rated Conditions – General for all Models
Parameter
Description
Output (two-wire)
Analog 4 to 20 mA or digital communications DE mode. Options available for
FOUNDATION Fieldbus and HART protocol.
Supply Voltage Effect
±0.005% span per volt.
Damping Time Constant
Adjustable from 0 to 32 seconds digital damping.
RFI Protection (Standard)
Negligible (20 to 1000 MHz at 30 volts per meter).
CE Conformity (Europe)
89/336/EEC, Electromagnetic Compatibility (EMC) Directive.
Physical and Approval Bodies
Parameter
Description
Process Interface
See Model Selection Guide for Material Options for desired seal type.
Seal Barrier Diaphgram
316L Stainless Steel, Monel, Hastelloy C, Tantalum
Seal Gasket Materials
Klinger C-4401 (non-asbestos)
Mounting Bracket
Carbon Steel (Zinc-Chromate plated) or Stainless Steel.
Fill Fluid (Meter Body)
Silicone (DC 200)
CTFE (Chlorotrifluoroethylene)
S.G. @ 25°C = 0.94
S.G. @ 25°C = 1.89
Fill Fluid (Secondary)
Silicone (DC 200)
CTFE (Chlorotrifluoroethylene)
Silicone (DC 704)
NEOBEE M-20
Syltherm 800
S.G. @ 25°C = 0.94
S.G. @ 25°C = 1.89
S.G. @ 25°C = 1.07
S.G. @ 25°C = 0.90
S.G. @ 25°C = 0.93
Electronic Housing
Epoxy-Polyester hybrid paint. Low copper-aluminum alloy. Meets NEMA 4X (watertight)
and NEMA 7 (explosion proof). Stainless steel optional.
Capillary Tubing
Armored Stainless Steel or PVC Coated Armored Stainless Steel.
Length: 5, 10, 15, 20, 25, and 35 feet (1.5, 3, 4.6, 6.1, 7.5, and 10.7 meters).
A 2 inch (51 millimeter) S.S. close-coupled nipple is also available. See Model
Selection Guide. Refer to Figure 3 for guide to maximum capillary length vs. diaphragm
diameter.
Wiring
Accepts up to 16 AWG (1.5 mm diameter).
Mounting
See Figure 6.
Dimensions
Transmitter: See Figures 9 and 10. Seal: See Model Selection Guide.
Net Weight
Transmitter: 15.4 pounds (7 Kg). Total weight is dependent on seal type and capillary
length.
Approval Bodies
Grafoil
-
Hazardous Areas
Approved as explosion proof and intrinsically safe for use in Class I, Division 1, Groups
A, B, C, D locations, and nonincendive for Class I, Division 2, Groups A, B, C, D
locations. Approved EEx ia IIC T4, T5, T6 and EEx d IIC T5, T6 per ATEX standards.
See attached Model Selection Guide for options.
-
Canadian Registration
Number (CRN)
- All ST 3000 model designs, except STG19L, STG99L, STG170, STG180, have been
registered in all provinces and territories in Canada and are marked CRN: 0F8914.5C.
Pressure Equipment Directive
(97/23/EC)
The ST 3000 pressure transmitters listed in this Specification have no pressurized
internal volume or have a pressurized internal volume rated less than 1,000 bar (14,500
psig) and/or have a maximum volume of less than 0.1 liter. Therefore, these
transmitters are either; not subject to the essential requirements of the directive
97/23/EC (PED, Annex 1) and shall not have the CE mark, or the manufacturer has the
free choice of a module when the CE mark is required for pressures > 200 bar (2,900
psig).
NOTE: Pressure transmitters that are part of safety equipment for the protection of piping (systems) or vessel(s) from
exceeding allowable pressure limits, (equipment with safety functions in accordance with Pressure Equipment Directive
97/23/EC article 1, 2.1.3), require separate examination.
34-ST-03-64
Page 10
Maximum Ambient
Temperature (°F)
200
180
160
140
120
100
80
60
40
20
0
185 185
165
165
140 140
ST3000
DP/I
LGP/I & AP/I
200
350
450
Process Interface Temperature (°F)
20385
Figure 2—Ambient temperature and process interface chart.
S100 Remote Seal Maximum Capillary Length
35
This chart is intended to serve
as a guide in selecting the
appropriate diaphragm size for
the required capillary length.
30
Maximum
Length (ft.)
25
20
15
ST3000
10
DP/I
5
0
LGP/I & AP/I
1.9
2.4
3.5
2.9
Diaphragm Size (in.)
4.1
Figure 3—Maximum capillary length and diaphragm size chart.
20337
34-ST-03-64
Page 11
Maximum Pressure Limited
by Flange Rating of Seal
10000
9000
8000
7000
6000
5000
193
psig
Silicone DC704
30 to 450°F
4000
3000
Silicone DC200
-40 to 350°F
2000
1000
900
800
700
600
500
400
1Atm
0
psig
CTFE
5 to 300°F
-9
psig
300
200
100 90
80
70
60
50
40
30
Special High Vacuum
Construction required.
Consult STC.
20
Pressure
(mmHgA)
10
-40
5
25 30
0
-100
175
100
450
350
200
300
500
400
Process Temperature (Degrees F)
-14
psig
Maximum Pressure Limited
by Flange Rating of Seal
10000
9000
8000
7000
6000
5000
193
psig
Syltherm 800
-40 to 600°F
90
psig
4000
NEOBEE M-20
30 to 400°F
3000
2000
1000
900
800
700
600
500
400
1Atm
0
psig
-9
psig
300
200
100 90
80
70
60
50
40
30
20
Pressure
(mmHgA)
10
-40
-100
5
0
25 30
175
100
550
450
200
400
Process Temperature (Degrees F)
Figure 4—ST 3000 Remote Seals operable limits for pressure vs. temperature.
500
-14
psig
600
20335
34-ST-03-64
Page 12
1440
Operating
Area
1200
Loop Resistance 800
(ohms)
650
NOTE: A minimum of 250
ohms of loop resistance is
necessary to support
communication. Loop
resistance equals barrier
resistance plus wire
resistance plus receiver
resistance. Also, 45 volt
operation is permitted if not
an intrinsically safe
installation.
450
250
0
10.8
16.28
37.0
25
28.3
20.63
42.4
Supply Voltage
20338
Figure 5—Supply voltage/loop resistance chart.
LP Side
Maximum level
H2
Fixed
ref. leg
Variable
Head
H1
Minimum level
.
HP Side
24249
NOTE: Lower flange seal should not be mounted over 22 feet below or above
the transmitter for silicone fill fluid (11 feet for CTFE fill fluid) with tank at one
atmosphere. The combination of tank vacuum and high pressure capillary
head effect should not exceed 9 psi vacuum (300 mmHg absolute).
Consult Honeywell for installation of STR13D.
Figure 6—The ST 3000 transmitter with remote diaphragm seals shown mounted on a tank.
34-ST-03-64
Page 13
Application Data*
Liquid Level: Closed Tank
Determine the minimum and
maximum pressure differentials to
be measured (Figure 7).
PMin = (SGp x a) – (SGf x d)
= LRV when HP at bottom
of tank
= –URV when LP at
bottom of tank
PMax = (SGp x b) – (SGf x d)
= URV when HP at bottom
of tank
= –LRV when LP at bottom
of tank
Max
Level
LP
b
Min
Level
a
HP
Transmitter above datum
Max
Level
LP
Where:
Minimum level at 4 mA
Maximum level at 20 mA
a = distance between bottom
tap and minimum level
b
Min
Level
a
HP
Transmitter at datum
b = distance between bottom
tap and maximum level
d = distance between taps
SGf = Specific Gravity of capillary
fill fluid (see page 8 for
values)
SGp = Specific Gravity of
process fluid
Max
Level
LP
b
Min
Level
a
HP
Transmitter below datum
24253
Figure 7—Closed tank liquid level measurement distances.
* Contact STC-Phoenix concerning
applications for model STR13D.
34-ST-03-64
Page 14
Density or Interface*
Calculate the minimum and
maximum pressure differentials to
be measured.
Pmin = (SGmin - SGf) x (d);
minimum density, 4mA
output
LP
Pmax = (SGmax - SGf) x (d);
maximum density, 20mA
output
Where:
HP
d = distance between the
taps
24257
SGmax = maximum Specific
Gravity
SGmin = minimum Specific
Gravity
SGf = Specific Gravity of
capillary fill fluid (see
page 8 for values)
Figure 8—Density, direct acting instrument configuration.
* Contact STC-Phoenix concerning
applications for model STR13D.
34-ST-03-64
Page 15
With Smart meter
Removal 45.7
Clearance 1.8
for All Caps
82.9
3.26
53.1
2.09
Without
meter
94.9
3.74
65.1
2.56
With Analog
meter
Reference
Dimensions:
millimeters
inches
Without
meter
3.6
0.14
Plug
135
5.32
55.3
2.18
Optional
meters
23.5
.925
Optional external
ground
Rotational
lock
STR12D, STR13D
DP/I Remote Seal
with Horizontal
Pipe Mount
LP seal
omitted for
clarity
85
3.35
42.5
1.67
With Smart meter
Removal 45.7
Clearance 1.8
for All Caps
82.9
3.26
53.1
2.09
Without
meter
94.9
3.74
65.1
2.56
With Analog meter
135
5.32
Without
meter
55.3
2.18
23.5
.925
Optional external
ground
71.1
2.80 SQ.
With Smart meter
Removal 45.7
Clearance 1.8
for All Caps
50
1.97
82.9
3.26
53.1
2.09
Without
meter
94.9
3.74
65.1
2.56
3.6
Plug
0.14
Optional
meters
STR14A
AP/I Remote Seal
with Horizontal
Pipe Mount
Rotational
lock
Seal
omitted
for clarity
With Analog meter
135
5.32
Without
meter
23.5
.925
STR14G, STR17G
LGP/I Remote Seal
with Horizontal
Pipe Mount
55.3
2.18
Optional external
ground
3.6 Plug
0.14
Optional
meters
Rotational
lock
Seal
omitted
for clarity
24261
Figure 9a —Approximate horizontal mounting dimensions for Remote Seal Transmitter.
34-ST-03-64
Page 16
With Smart meter
Removal 45.7
Clearance 1.8
for All Caps
82.9
3.26
53.1
2.09
Without
meter
94.9
3.74
65.1
2.56
With Analog
meter
Reference
Dimensions:
millimeters
inches
Without
meter
3.6
135
5.32
0.14
Plug
55.3
2.18
Optional
meters
23.5
.925
Rotational
lock
Optional external
ground
STR12D, STR13D
DP/I Remote Seal
with Vertical
Pipe Mount
LP seal
omitted
for clarity
85
3.35
SQ
42.5 50
1.67 1.97
With Smart meter
Removal 45.7
Clearance 1.8
for All Caps
82.9
3.26
53.1
2.09
Without
meter
94.9
3.74
65.1
2.56
With Analog
meter
Without
meter
STR14A
AP/I Remote Seal
with Vertical
Pipe Mount
23.5
.925
135
5.32
55.3
2.18
Optional
meters
Rotational
lock
Optional external
ground
71.1
2.80 SQ.
With Smart meter
Removal 45.7
Clearance 1.8
for All Caps
82.9
3.26
53.1
2.09
Without
meter
94.9
3.74
65.1
2.56
3.6
0.14 Plug
Seal
omitted
for clarity
With Analog
meter
Without
meter
23.5
.925
STR14G, STR17G
LGP/I Remote Seal
with Vertical Pipe
Mount (Flat Bracket)
135
5.32
55.3
2.18
Optional external
ground
3.6
Plug
0.14
Optional
meters
Rotational
lock
Seal
omitted
for clarity
24262
Figure 9b —Approximate vertical mounting dimensions for Remote Seal Transmitter.
34-ST-03-64
Page 17
Options
Mounting Bracket
The angle mounting bracket is
available in either zinc-plated
carbon steel or stainless steel and
is suitable for horizontal or vertical
mounting on a two inch (50
millimeter) pipe, as well as wall
mounting. An optional flat
mounting bracket is also available
in carbon steel for two inch (50
millimeter) pipe mounting.
Indicating Meter
(ME and SM Options)
Two integral meter options are
available. An analog meter (option
ME) is available with a 0 to 100%
linear scale. The Smart Meter
(option SM) provides an LCD
display for both analog and digital
output and can be configured to
display pressure in pre-selected
engineering units.
HART Protocol Compatibility
(Option HC)
An optional electronics module is
available for the ST 3000 that
provides HART Protocol
compatibility. Transmitters with
the HART Option are compatible
with the AMS System. (Contact
your AMS Supplier if an upgrade
is required.)
Lightning Protection
(Option LP)
A terminal block with circuitry that
protects the transmitter from
transient surges induced by
nearby lightning strikes is
available.
Indicator Configuration
(Option CI)
Provides custom configuration of
Smart Meters
Tagging (Option TG)
Ordering Information
Contact your nearest Honeywell sales
office, or
In the U.S.:
Honeywell
Industrial Automation & Control
16404 North Black Canyon Hwy.
Phoenix, AZ 85053
1-800-288-7491
Up to 30 characters can be added
on the stainless steel nameplate
mounted on the transmitter’s
In Canada:
electronics housing at no extra cost.
The Honeywell Centre
Note that a separate nameplate on
155 Gordon Baker Rd.
the meter body contains the serial
North York, Ontario M2H 3N7
number and body-related data. A
1-800-461-0013
stainless steel wired on tag with
additional data of up to 4 lines of 28 In Latin America:
Honeywell Inc.
characters is also available. The
480
Sawgrass
Corporate Parkway,
number of characters for tagging
Suite 200
includes spaces.
Sunrise, FL 33325
Transmitter Configuration
(Option TC)
The factory can configure the
transmitter linear/square root
extraction, damping time, LRV,
URV and mode (analog/digital) and
enter an ID tag of up to eight
characters and scratchpad
information as specified.
Custom Calibration and ID in
Memory (Option CC)
The factory can calibrate any range
within the scope of the transmitter’s
range and enter an ID tag of up to
eight characters in the transmitter’s
memory.
FOUNDATION Fieldbus
(Option FF)
Equips transmitter with FF
protocol for use in 31.25 kbit/s
FF networks. See document
34-ST-03-72 for additional
information on ST 3000
Fieldbus transmitters.
(954) 845-2600
In Europe and Africa:
Honeywell S. A.
Avenue du Bourget 1
1140 Brussels, Belgium
In Eastern Europe:
Honeywell Praha,
s.r.o. Budejovicka 1
140 21 Prague 4,
Czech Republic
In the Middle East:
Honeywell Middle East Ltd.
Khalifa Street,
Sheikh Faisal Building
Abu Dhabi, U. A. E.
In Asia:
Honeywell Asia Pacific Inc.
Honeywell Building,
17 Changi Business Park Central 1
Singapore 486073
Republic of Singapore
In the Pacific:
Honeywell Pty Ltd.
5 Thomas Holt Drive
North Ryde NSW Australia 2113
(61 2) 9353 7000
In Japan:
Honeywell K.K.
14-6 Shibaura 1-chrome
Minato-ku, Tokyo, Japan 105-0023
Specifications are subject to change without notice.
Or, visit Honeywell on the World Wide
Web at: http://www.honeywell.com
34-ST-03-64
Page 18
34-ST-16-32 Issue 24
Instructions
Select the desired Key Number. The arrow to the right marks the selection available.
Make one selection from each Table I and II using the column below the proper arrow.
Select as many Table III options as desired (if no options or approvals are desired, specify 9X).
A (Š) denotes unrestricted availability. A letter denotes restricted availability.
Restrictions follow Table IV.
Key Number
______
I
-
___
II
-
____________
III (Optional)
-
IV
_ _, _ _
+
KEY NUMBER
Description
0-10" to 0-400" H2O/0-25 to 0-1000 mbar
Body Rating*: 3000 psi (172 bar) Compound Characterized
0-5 to 0-100 psi/0-0.34 to 0-7 bar
Body Rating*: 3000 psi (172 bar)
Note: With Model STR12D, Table III, Option CM must be specified.
XXXX
Selection
Availabil
STR12D (Note)
STR13D
* Remote seal system pressure rating is body rating or seal rating, whichever is less.
TABLE I - METER BODY
1 Remote Seal (High Side)
Number of Seals
2 Remote Seals
Fill Fluid
(Meter Body)
Construction
Standard Dual Head
1 Remote Seal (Low Side)
Silicone (DC 200)
CTFE
Non-Wetted Adapter Head Material
316 St. St.
Carbon St. (zinc-plated)
316 St. St. for Close-Couple
See Specification Sheet 34-ST-03-64 for figures on construction.
1__
2__
3__
_1_
_2_
Š
Š
Š
Š
__A
__B
__D
Š Š
Š Š
Š
Š
Š
Š
q q
y
y
34-ST-03-64
Page 19
STR1_D
TABLE II - SEALS
Format for Seal Selection:
Specify 12 characters
Selection
2
3
____________
Common
Required Seal
Note:
The first 3 characters are common to all seals.
When selecting required seal, you must specify
only the 9 selections within the required seal.
Silicone (DC 200)
Secondary
CTFE
Fill
Silicone (DC 704)
Neobee(M20) **
1___________
2___________
3___________
4___________
5___________
Š Š
Š Š
_A__________
_B__________
_C__________
_D__________
_E__________
_F__________
_G__________
_H__________
_J__________
_K__________
_L__________
_M__________
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
_2__________
__0_________
z
z
Š Š
_ _ _ AFA _ _ _ _ _ _
_ _ _ AFC _ _ _ _ _ _
_ _ _ AFM _ _ _ _ _ _
Š Š
Š Š
Š Š
_ _ _ _ _ _ AA _ _ _ _
_ _ _ _ _ _ AB _ _ _ _
_ _ _ _ _ _ AC _ _ _ _
_ _ _ _ _ _ AE _ _ _ _
________1___
Š
Š
Š
Š
Š
316 St. St.
________2___
Š Š
No Selection
_________0__
Š Š
Sytles
No Selection
__________0_
Š Š
Gasket
No Selection
___________0
Š Š
Syltherm 800 ***
5 feet
10 feet
15 feet
20 feet
25 feet
Connection
of Remote
Seal to
Meter Body
Capillary
Length
35 feet
5 feet
10 feet
15 feet
20 feet
25 feet
1.5 m
3.0 m
4.5 m
6.1 m
7.5 m
SS Armor
10.7 m
1.5 m
3.0 m
4.5 m
6.1 m
7.5 m
PVC Coated
SS Armor
35 feet
10.7 m
2 inch long SS nipple close-coupled
No Selection
Flush
Diaphragm
Flange
Diameter
Size
3.5"
3"
Flanged
Seal
p p
Š Š
p p
Flange Pressure
Rating *
ANSI Class 150
ANSI Class 300
DIN DN80-PN40
Diaphragm
Upper
Insert
Wetted Material
Non-Wetted
Material (upper)
Bolts
316L SS
316 St. St.
Hastelloy C 316 St. St.
Hastelloy C Hastelloy C
Monel
Monel
CS with Polyester
Powder Coating
*
Standard facing 125-250 AARH RF (raised face) serrated surface finish.
**
Limited vacuum availability.
***
Minimum static pressure requirement. No vacuum allowed. See Specifications' Figure 4.
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
Š
Š
Š
Š
Š
Table II co
34-ST-03-64
Page 20
STR1_D
TABLE II - SEALS (continued)
2
3
_ _ _ CAA _ _ _ _ _ _
_ _ _ CCA _ _ _ _ _ _
_ _ _ CCC _ _ _ _ _ _
_ _ _ CGA _ _ _ _ _ _
_ _ _ CGC _ _ _ _ _ _
_ _ _ CDA _ _ _ _ _ _
_ _ _ CDC _ _ _ _ _ _
t
t
t
t
t
t
t
t
t
t
t
t
t
t
_ _ _ DAA _ _ _ _ _ _
_ _ _ DCA _ _ _ _ _ _
_ _ _ DCC _ _ _ _ _ _
_ _ _ DGA _ _ _ _ _ _
_ _ _ DGC _ _ _ _ _ _
_ _ _ DDA _ _ _ _ _ _
_ _ _ DDC _ _ _ _ _ _
_ _ _ DFA _ _ _ _ _ _
_ _ _ DFC _ _ _ _ _ _
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
_ _ _ _ _ _ BA _ _ _ _
_ _ _ _ _ _ BB _ _ _ _
_ _ _ _ _ _ BC _ _ _ _
_ _ _ _ _ _ BE _ _ _ _
_ _ _ _ _ _ BF _ _ _ _
_ _ _ _ _ _ BG _ _ _ _
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
________4___
________5___
Š Š
Š Š
_________0__
__________0 _
Š Š
Š Š
__________7_
Š Š
___________K
c
___________G
d d
Flange
Flange
Const. - See
Construction - See Spec.
Diameter
Size
Pressure
Spec. Figure
34-ST-03-64 figure
Rating *
34-ST-03-64
ANSI 150
ANSI 150
ANSI 300
ANSI 150
ANSI 300
ANSI 150
12
12
12
11
11
11
ANSI 300
ANSI 150
ANSI 150
ANSI 300
ANSI 150
ANSI 300
ANSI 150
ANSI 300
ANSI 150
11
12
12
12
12
12
12
11
11
1/2"
1"
2.9"
1-1/2"
2"
1/2"
1"
Flush
Flanged
Seal with
Lower
Selection
Diaphragm
1-1/2"
4.1"
2"
3"
Wetted Material
ANSI 300
11
Diaphragm
Lower
316L SS
Hastelloy C
Hastelloy C
Monel
Tantalum
316 St. St.
316 St. St.
Hastelloy C
Monel
316 St. St.
Tantalum
Hastelloy C
Non-Wetted
Material (upper,
316 St. St.
316 St. St.
upper insert)
CS
316 St. St.
Bolts
No Selection
Without 1/4" NPT Flushing
Connection
With 1/4" NPT Flushing
Connection
Klinger C-4401
(non-asbestos)
Styles
Gasket
Upper
Grafoil
Upper Insert
Table II continued next page
* Standard facing 125-250 AARH RF (raised face) serrated finish.
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
c
34-ST-03-64
Page 21
STR1_D
TABLE II - SEALS (continued)
Selection
2
3
_ _ _ EFA _ _ _ _ _ _
_ _ _ EFC _ _ _ _ _ _
_ _ _ EFM _ _ _ _ _ _
t
t
t
t
t
t
_ _ _ FGA _ _ _ _ _ _
_ _ _ FGC _ _ _ _ _ _
_ _ _ FGP _ _ _ _ _ _
Š Š
Š Š
Š Š
_ _ _ _ _ _ EA _ _ _ _
_ _ _ _ _ _ EB _ _ _ _
_ _ _ _ _ _ EC _ _ _ _
Š
Š
Š
Š
Š
Š
Š
Š
6"
__________2 _
__________4_
__________6_
Š
Š
Š
Š
Š
Š
Š
Š
No Selection
___________0
Š Š
_ _ _ GFA _ _ _ _ _ _
Š Š
_ _ _ _ _ _ GA _ _ _ _
_ _ _ _ _ _ GB _ _ _ _
_ _ _ _ _ _ GC _ _ _ _
_ _ _ _ _ _ GE _ _ _ _
________0___
Š
Š
Š
Š
Š
No Selection
_________0__
Š Š
No Selection
__________0 _
Š Š
___________0
Š Š
Diaphragm
Flange
Flange Pressure
Diameter
Size
Rating *
2.9"
(2.85")
3"
ANSI Class 150
(2.85" OD ANSI Class 300
extension) DIN DN80-PN40
Flange
Seal with
4"
3.5"
Extended
Diaphragm
ANSI Class 150
(3.70" OD ANSI Class 300
extension) DIN DN100-PN40
Diaphragm
Lower
Wetted Material
316L SS
316 St. St.
Hastelloy C 316 St. St.
Non-Wetted
Material (flange)
Hastelloy C Hastelloy C
CS with Polyester Powder
Coating
Bolts
Extension
Length
No Selection
2"
4"
Diaphragm
________7___
_________0__
Flange Flange Pressure Rating
Diameter
Size
3.5"
3"
Dependent on customer
flange
ANSI Class 150/300/600
Diaphragm
Pancake
Seal
Wetted Material
Non-Wetted
Material
Bolts
Styles
Body
316L SS
316 St. St.
Hastelloy C 316 St. St.
Hastelloy C Hastelloy C
Monel
Monel
No Selection
No Selection
Table II continued next page
* Standard facing 125-250 AARH RF (raised face) serrated finish.
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
Š
Š
Š
Š
Š
34-ST-03-64
Page 22
STR1_D
TABLE II - SEALS (continued)
Selection
2
3
_ _ _ EFA _ _ _ _ _ _
_ _ _ EFC _ _ _ _ _ _
_ _ _ EFM _ _ _ _ _ _
t
t
t
t
t
t
_ _ _ FGA _ _ _ _ _ _
_ _ _ FGC _ _ _ _ _ _
_ _ _ FGP _ _ _ _ _ _
Š Š
Š Š
Š Š
_ _ _ _ _ _ EA _ _ _ _
_ _ _ _ _ _ EB _ _ _ _
_ _ _ _ _ _ EC _ _ _ _
Š
Š
Š
Š
Š
Š
Š
Š
6"
__________2 _
__________4_
__________6_
Š
Š
Š
Š
Š
Š
Š
Š
No Selection
___________0
Š Š
_ _ _ GFA _ _ _ _ _ _
Š Š
_ _ _ _ _ _ GA _ _ _ _
_ _ _ _ _ _ GB _ _ _ _
_ _ _ _ _ _ GC _ _ _ _
_ _ _ _ _ _ GE _ _ _ _
________0___
Š
Š
Š
Š
Š
No Selection
_________0__
Š Š
No Selection
__________0 _
Š Š
___________0
Š Š
Diaphragm
Flange
Flange Pressure
Diameter
Size
Rating *
2.9"
(2.85")
3"
ANSI Class 150
(2.85" OD ANSI Class 300
extension) DIN DN80-PN40
Flange
Seal with
4"
3.5"
Extended
Diaphragm
ANSI Class 150
(3.70" OD ANSI Class 300
extension) DIN DN100-PN40
Diaphragm
Lower
Wetted Material
316L SS
316 St. St.
Hastelloy C 316 St. St.
Non-Wetted
Material (flange)
Hastelloy C Hastelloy C
CS with Polyester Powder
Coating
Bolts
Extension
Length
No Selection
2"
4"
Diaphragm
________7___
_________0__
Flange Flange Pressure Rating
Diameter
Size
3.5"
3"
Dependent on customer
flange
ANSI Class 150/300/600
Diaphragm
Pancake
Seal
Wetted Material
Non-Wetted
Material
Bolts
Styles
Body
316L SS
316 St. St.
Hastelloy C 316 St. St.
Hastelloy C Hastelloy C
Monel
Monel
No Selection
No Selection
Table II continued next page
* Standard facing 125-250 AARH RF (raised face) serrated finish.
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
Š
Š
Š
Š
Š
34-ST-03-64
Page 23
STR1_D
TABLE II - SEALS (continued)
Diaphragm
Diameter
Selection
2
3
_ _ _ HM0 _ _ _ _ _ _
v
v
_ _ _ _ _ _ HA _ _ _ _
_ _ _ _ _ _ HB _ _ _ _
Š Š
Hastelloy C 316 St. St.
No Selection
________0___
Š Š
No Selection
_________0__
Š Š
No Selection
No Selection
__________0 _
Š Š
___________0
Š Š
Flange
Flange Pressure
Size
Rating
Taylor
3.5"
Chemical
Tee "Taylor"
Wedge
750 psi
Wedge
5" O.D.
Diaphragm
Wetted Material
Non-Wetted
316L SS
Lower
316 St. St.
Š Š
Material
Bolts
Styles
Diaphragm Threaded Process
Diameter
Pressure
Connection Size
(NPT Female)
Rating
CS Bolts 304 SS
Bolts
_ _ _ KJG _ _ _ _ _ _
t
t
1250
_ _ _ KKG _ _ _ _ _ _
t
t
psi
_ _ _ KLG _ _ _ _ _ _
t
t
_ _ _ LJG _ _ _ _ _ _
Š Š
1/2" NPT
2.9"
3/4" NPT
1" NPT
2500
psi
1/2" NPT
4.1"
Seal with
Threaded
1500
750
_ _ _ LKG _ _ _ _ _ _
Š Š
1" NPT
psi
psi
_ _ _ LLG _ _ _ _ _ _
Š Š
Diaphragm
Process
Connection
3/4" NPT
Wetted Material
Lower
316L SS
CS
_ _ _ _ _ _ JA _ _ _ _
Š Š
316L SS
316 St. St.
_ _ _ _ _ _ JB _ _ _ _
Š Š
Hastelloy C 316 St. St.
Š Š
Hastelloy C Hastelloy C
_ _ _ _ _ _ JC _ _ _ _
_ _ _ _ _ _ JD _ _ _ _
Monel
Monel
_ _ _ _ _ _ JE _ _ _ _
Š Š
Tantalum
316 St. St.
Hastelloy C.
_ _ _ _ _ _ JF _ _ _ _
_ _ _ _ _ _ JG _ _ _ _
Š Š
Tantalum
Š Š
Š Š
Non-Wetted
CS with Polyester
Material
Powder Coating
(upper)
Stainless Steel
________A___
________C___
w w
Bolts
C.S.
_________C__
Š Š
304 St. St.
_________D__
Š Š
W/O Flushing Connection
__________A _
Š Š
With Flushing Connection
__________F _
Š Š
Klinger C-4401
___________K
c
___________G
d d
Styles
Gasket
Š Š
c
(non-asbestos)
Grafoil
Table II continued next page
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
34-ST-03-64
Page 24
STR1_D
TABLE II - SEALS (continued)
Flange
Diameter
Size
2.9"
3"
Customer clamp rating or
4.1"
4"
600 psi, whichever is less
Sanitary
Seal
Selection
Diaphragm
2
3
t
t
Pressure Rating
_ _ _ PF0 _ _ _ _ _ _
_ _ _ QG0 _ _ _ _ _ _
Š Š
______NA____
Š Š
________0___
Š Š
No Selection
_________0__
Š Š
Tri-Clover Tri-Clamp
__________8 _
Š Š
No Selection
___________0
Š Š
Diaphragm
Wetted Material
316L SS
Non-Wetted
No Selection
Body
316 St. St.
Material
Bolts
Styles
Gasket
Note: All sanitary seals have dairy grade 3A approval.
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
TABLE III - OPTIONS
None
00
FOUNDATION Fieldbus Communications
FF
HART Protocol compatible electronics
HC
Analog Meter (0-100 Even 0-10 Square Root)
ME
Smart Meter
SM
Customer Configuration of Smart Meter
CI
Local Zero & Span
ZS
Local Zero
LZ
Lightning Protection
LP
Custom Calibration and I.D. in Memory
CC
Transmitter Configuration - non-Fieldbus
TC
Write Protection
WP
End Cap Live Circuit Warning Label in Spanish (only with ATEX 3D)
SP
PG
End Cap Live Circuit Warning Label in Portuguese (only with ATEX 3D)
TL
End Cap Live Circuit Warning Label in Italian (only with ATEX 3D)
GE
End Cap Live Circuit Warning Label in German (only with ATEX 3D)
A286SS (NACE) Bolts and 302/304SS (NACE) Nuts for Heads
CR
Stainless Steel Customer Wired-On Tag
TG
(4 lines, 28 characters per line, customer supplied information)
TB
Stainless Steel Customer Wired-On Tag (blank)
Mounting Bracket - Carbon Steel
MB
Mounting Bracket - ST. ST.
SB
Flat Mounting Bracket
FB
316 ST.ST. Electronics Housing - with M20 Conduit Connections
SH
1/2" NPT to M20 316SS Conduit Adapter (BASEEFA EEx d IIC)
A1
1/2" NPT to 3/4" NPT 316 SS Conduit Adapter
A2
Stainless Steel Housing with M20 to 1/2" NPT 316 SS Conduit
A3
Adapter (use for FM and CSA Approvals)
Clean Transmitter for Oxygen or Chlorine Service with Certificate
0X
Marine Type Approvals (DNV, ABS, BV & LR)
MT
Over-Pressure Leak Test with F3392 Certificate
TP
Calibration Test Report and Certificate of Conformance (F3399)
F1
Certificate of Conformance (F3391)
F3
Certificate of Origin (F0195)
F5
FMEDA (SIL) Certificate
F6
NACE Certificate (F0198)
F7
Additional Warranty - 1 year
W1
Additional Warranty - 2 years
W2
Additional Warranty - 3 years
W3
Additional Warranty - 4 years
W4
Š
r
e
Š
Š
f
Š
r
e
Š
Š
f
m m
x x
Š
Š
Š
Š
Š
Š
Š
Š
a
a
a
a
a
a
a
a
b
b
b
b
Š Š
Š Š
Š
Š
Š
Š
Š
Š
Š
Š
n n
n n
u u
i i
b
b
h h
2 2
Š
Š
Š
Š
Š
Š
Š
Š
Š
Š
b
o o
Š
Š
Š
Š
Š
Š
Š
Š
b
34-ST-03-64
Page 25
STR1_D
TABLE III - OPTIONS (continued)
Selection
2
3
Approval
Body
Approval Type
No hazardous location approvals
Explosion Proof
Factory
Dust Ignition Proof
Mutual
Non-Incendive
Intrinsically Safe
CSA
Explosion Proof
Dust Ignition Proof
Intrinsically Safe
SA
Intrinsically Safe
(Australia) Non-Sparking
Intrinsically Safe, Zone
0/1
Flameproof, Zone 1
Location or Classification
Class I, Div. 1, Groups A,B,C,D
Class II, III Div. 1, Groups E,F,G
Class I, Div. 2, Groups A,B,C,D
Class I, II, III, Div. 1, Groups
A,B,C,D,E,F,G
Class I, Div. 1, Groups B,C,D
Class II, III, Div. 1, Groups E,F,G
Class I, II, III, Div. 1, Groups
A,B,C,D,E,F,G
Ex ia IIC T4
Ex n IIC T6 (T4 with SM option)
Ex II 1G
EEx ia IIC T4, T5,T6
Int. Safe, Zone 0/1, or
Ex II 2G
EEx d IIC T5, T6,
Enclosure IP 66/67
Ex II 3G
EEx nA, IIC T6
(Honeywell). Enclosure IP 66/67
Ex II 1 G EEx ia IIC T4, T5, T6
Ex II 2 G EEx d IIC T5, T6
Flameproof, Zone 1, or
Ex II 3 G EEx nA, IIC T6 (Honeywell)
Non-Sparking, Zone 2
Enclosure IP 66/67
Ex d IIC T5
ATEX*
Non-Sparking, Zone 2
Multiple Marking**
INMETRO Flameproof, Zone 1
(Brazil)
9X
Š Š
1C
Š Š
2J
Š Š
4G
Š Š
3S
Š Š
3D
Š Š
3N
Š Š
3H
Š Š
6D
Š Š
b
*See ATEX installation requirements in the ST 3000 User's Manual
**The user must determine the type of protection required for installation of the equipment. The
user shall then check the box [a] adjacent to the type of protection used on the equipment
certification nameplate. Once a type of protection has been checked on the nameplate, the
equipment shall not then be reinstalled using any of the other certification types.
TABLE IV
Factory Identification
XXXX
Š Š
34-ST-03-64
Page 26
RESTRICTIONS
Restriction
Table
Letter
a
III
b
c
d
Available Only With
Not Available With
Selection
Table
Selection
3D or 3H
Select only one option from this group
II
_ _ _ _ _ _ BF _ _ _ _,
_ _ _ _ _ _ BG _ _ _ _,
_ _ _ _ _ _ JF _ _ _ _,
_ _ _ _ _ _ JG _ _ _ _,
II
_ _ _ _ _ _ BF _ _ _ _,
_ _ _ _ _ _ BG _ _ _ _,
_ _ _ _ _ _ JF _ _ _ _,
_ _ _ _ _ _ JG _ _ _ _,
f
III
h
I, II
SM
_2_-2___________
i
III
1C or 2J
e
m
n
o
p
q
r
s
t
III
III
4G
III
III
ME, FF
1C, 2J
CR
II
II
DC704 and Syltherm 800
fills and close-couple require
SS seal upper.
_ _ _ CAA _ _ 5 _ _ _,
_ _ _ CCA _ _ 5 _ _ _,
_ _ _ CCC _ _ 5 _ _ _,
_ _ _ DAA _ _ 5 _ _ _,
_ _ _ DCA _ _ 5 _ _ _,
_ _ _ DCC _ _ 5 _ _ _,
_ _ _ DGA _ _ 5 _ _ _,
_ _ _ DGC _ _ 5 _ _ _,
_ _ _ DDA _ _ 5 _ _ _,
_ _ _ _ _ _ GE _ _ _ _,
________A___
2 _ _ _ _ _ _ _ _ _ _ _ _,
4____________
III
TC, ME, 4G, 3S
Must be specified with Model STR12D
I
2__
II
_ B _ _ _ _ _ _ _ _ _ _,
_ C _ _ _ _ _ _ _ _ _ _,
_ D _ _ _ _ _ _ _ _ _ _,
_ E _ _ _ _ _ _ _ _ _ _,
_ F _ _ _ _ _ _ _ _ _ _,
_ H _ _ _ _ _ _ _ _ _ _,
_ J _ _ _ _ _ _ _ _ _ _,
_ K _ _ _ _ _ _ _ _ _ _,
_ L _ _ _ _ _ _ _ _ _ _,
_M__________
34-ST-03-64
Page 27
RESTRICTIONS Continued
u
III
1C, 2J
w
x
III
FF, SM
y
I
1 _ _, 3 _ _
II
_2__________
z
I
III
II
_ _ _ _ _ _ JA _ _ _ _
MB, SB, FB
DC704 and Syltherm 800
fills and close-couple require
SS seal upper.
_ _ _ CAA _ _ 5 _ _ _,
_ _ _ CCA _ _ 5 _ _ _,
_ _ _ CCC _ _ 5 _ _ _,
_ _ _ DAA _ _ 5 _ _ _,
_ _ _ DCA _ _ 5 _ _ _,
_ _ _ DCC _ _ 5 _ _ _,
_ _ _ DGA _ _ 5 _ _ _,
_ _ _ DGC _ _ 5 _ _ _,
_ _ _ DDA _ _ 5 _ _ _,
_ _ _ _ _ _ GE _ _ _ _,
________A___
__D
2
Note:
II
III
FB
See ST-83 for Published Specials with pricing.
See ST-89 and User's Manual for part numbers.
See ST-OE-9 for OMS Order Entry Information including TC, manuals, certificates,
drawings and SPINS.
See ST-OD-1 for tagging, ID, Transmitter Configuration (TC) and calibration including
factory default values.
To request a quote for a non-published "special", fax RFQ w/ Application Data Sht
(34-ST-18-01) to Mktg. Applications.
See Specification 34-ST-03-64 for Seal dimensions.
34-ST-03-64
Page 28
TABLE 1 - Flush Flanged Seals
Number of
Seals
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
Diaphragm Diameter = 3.5"
Seal Materials
Flange Size - Pressure Rating - Code
Wetted
Non-wetted
AFA
AFC
AFM
AA
AB
AC
AE
AA
AB
AC
AE
AA
AB
AC
AE
AA
AB
AC
AE
1
1
1
1
2
2
2
2
1
1
1
1
2
2
2
2
407
464
640
549
580
638
741
681
814
928
1279
1098
1161
1275
1481
1363
421
478
741
563
638
696
828
740
843
957
1481
1126
1275
1391
1656
1479
473
530
780
615
647
706
860
748
947
1061
1561
1230
1289
1412
1720
1495
TABLE 2 - Flush Flanged Seals with Lowers
Number of
Seals
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
Diaphragm Diameter = 2.9"
Seal Materials
Flange Size - Pressure Rating - Code
Wetted
Non-wetted
CAA
CCA
CCC
CGA
CGC
CDA
CDC
BA
BB
BC
BE
BF
BG
BA
BB
BC
BE
BF
BG
BA
BB
BC
BE
BF
BG
BA
BB
BC
BE
BF
BG
4
4
4
4
4
4
5
5
5
5
5
5
4
4
4
4
4
4
5
5
5
5
5
5
496
516
1002
567
548
1032
357
378
865
429
409
895
990
1032
2004
1134
1094
2064
714
758
1729
860
819
1789
496
516
1002
567
548
1032
357
378
865
429
409
895
990
1032
2004
1134
1094
2064
714
758
1729
860
819
1789
496
516
1002
567
548
1032
357
378
865
429
409
895
990
1032
2004
1134
1094
2064
714
758
1729
860
819
1789
496
516
1002
567
548
1032
357
378
865
429
409
895
990
1032
2004
1134
1094
2064
714
758
1729
860
819
1789
496
516
1002
567
548
1032
357
378
865
429
409
895
990
1032
2004
1134
1094
2064
714
758
1729
860
819
1789
635
658
983
722
687
1013
411
432
759
498
463
788
1271
1315
1967
1444
1375
2027
822
866
1517
995
926
1577
685
708
1027
810
738
1057
432
455
773
556
485
803
1371
1415
2053
1619
1477
2114
866
909
1546
1111
970
1607
34-ST-03-64
Page 29
TABLE 3 - Flush Flanged Seals with Lowers
Number of
Seals
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
Diaphragm Diameter = 4.1"
Seal Materials
Flange Size - Pressure Rating - Code
Wetted
Non-wetted
DAA
DCA
DCC
DGA
DGC
DDA
DDC
DFA
DFC
BA
BB
BC
BE
BF
BG
BA
BB
BC
BE
BF
BG
BA
BB
BC
BE
BF
BG
BA
BB
BC
BE
BF
BG
4
4
4
4
4
4
5
5
5
5
5
5
4
4
4
4
4
4
5
5
5
5
5
5
748
748
770
748
770
685
599
881
1082
814
814
835
814
835
751
853
947
1146
1379
1379
1429
1379
1429
1280
1294
1490
1669
891
891
979
891
979
866
968
1047
1246
857
857
879
857
879
795
896
990
1190
1422
1422
1473
1422
1473
1323
1338
1533
1712
596
596
618
596
618
533
533
577
655
662
662
683
662
683
600
600
643
719
1227
1227
1278
1227
1278
1128
1041
1186
1241
740
740
826
740
826
714
714
743
820
706
706
727
706
727
643
643
685
763
1270
1270
1320
1270
1320
1172
1084
1094
1285
1496
1496
1540
1496
1540
1371
1575
1763
2164
1627
1627
1671
1627
1671
1502
1706
1893
2293
2757
2757
2859
2757
2859
2559
2589
2979
3337
1783
1783
1958
1783
1958
1731
1935
2093
2493
1715
1715
1758
1715
1758
1590
1791
1961
2381
2845
2845
2947
2845
2947
2647
2675
3067
3423
1192
1192
1236
1192
1236
1068
1068
1155
1309
1323
1323
1367
1323
1367
1199
1199
1286
1438
2641
2641
2555
2641
2555
2255
2255
2373
2481
1479
1479
1652
1479
1652
1427
1427
1486
1640
1411
1411
1455
1411
1455
1286
1286
1371
1525
2541
2541
2641
2541
2641
2343
2343
2459
2569
TABLE 4 - Price Add for Flush Flanged Seals with Lowers and Flushing Connection: Code = 7
Seal Materials
Number of
Seals
Wetted
Flange Size - Pressure Rating - Code
Diaph. Dia. = 2.9"
Diaph. Dia. = 4.1"
CAA, CCA, CCC, CGA,
DAA, DCA, DCC, DGA,
CGA, CDA, CDC
DGC, DDA, DDC,
DFA, DFC
1
1
1
1
1
1
2
2
2
2
2
2
BA
BB
BC
BE
BF
BG
BA
BB
BC
BE
BF
BG
44
44
138
131
44
138
88
88
274
260
88
274
115
115
159
145
115
159
231
231
318
290
231
318
34-ST-03-64
Page 30
TABLE 5 - Flanged Seals with Extended Diaphragms
Number of
Seals
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
Seal Materials
Wetted
EA
EB
EC
EA
EB
EC
EA
EB
EC
EA
EB
EC
EA
EB
EC
EA
EB
EC
Flange Size - Pressure Rating - Code
Extension
2
2
2
4
4
4
6
6
6
2
2
2
4
4
4
6
6
6
Diaphragm Diameter = 2.9"
Diaphragm Diameter = 3.5"
EFA
EFC
EFM
FGA
FGC
FGP
744
766
1135
787
810
1346
831
853
1559
1488
1531
2271
1575
1619
2693
1663
1706
3117
760
781
1151
803
825
1364
847
869
1577
1519
1563
2301
1607
1650
2727
1694
1737
3155
811
832
1201
854
876
1412
898
920
1623
1621
1665
2401
1709
1752
2823
1796
1839
3246
807
865
1973
865
922
2252
922
980
2533
1613
1729
3945
1729
1843
4505
1843
1960
5064
832
890
2001
890
948
2282
948
1006
2560
1665
1781
4004
1781
1895
4563
1895
2012
5120
890
948
2057
948
1006
2338
1006
1064
2618
1781
1895
4114
1895
2012
4676
2012
2129
5238
TABLE 6 - Seals with Threaded Process Connection with Carbon Steel Uppers: Code = A
Number of
Material -
Seals
Wetted without
Diaph. Dia. = 2.9"
Flange Size - Pressure Rating - Code
Diaph. Dia. = 4.1"
Flushing
KJG, KKG, KLG
LJG, LKG, LLG
173
233
254
605
307
285
658
348
466
508
1209
614
570
1315
371
459
523
1089
553
567
1199
743
919
1047
2179
1105
1134
2397
Connection
1
1
1
1
1
1
1
2
2
2
2
2
2
2
JA
JB
JC
JD
JE
JF
JG
JA
JB
JC
JD
JE
JF
JG
34-ST-03-64
Page 31
TABLE 7 - Seals with Threaded Process Connection with Stainless Steel Uppers: Code = C
Number of
Material -
Seals
Wetted without
Diaph. Dia. = 2.9"
Flange Size - Pressure Rating - Code
Diaph. Dia. = 4.1"
Flushing
KJG, KKG, KLG
LJG, LKG, LLG
370
393
743
445
422
795
741
784
1486
888
845
1590
611
676
1241
705
719
1349
1221
1353
2483
1409
1438
2699
Connection
1
1
1
1
1
1
2
2
2
2
2
2
JB
JC
JD
JE
JF
JG
JB
JC
JD
JE
JF
JG
TABLE 8 - Price Add for Seals with Threaded Process Connection and Flushing Connection: Code = F
Seal Materials
Number of
Seals
1
1
1
1
1
1
1
2
2
2
2
2
2
2
Wetted
JA
JB
JC
JD
JE
JF
JG
JA
JB
JC
JD
JE
JF
JG
Flange Size - Pressure Rating - Code
Diaph. Dia. = 2.9"
Diaph. Dia. = 4.1"
KJG, KKG, KLG
LJG, LKG, LLG
19
30
30
55
30
30
55
40
58
58
110
58
58
110
88
88
88
159
88
88
159
174
174
174
318
174
174
318
34-ST-03-64
Page 32
Type
Size
Nonwetted
Material
3” 150
CS
SS
3” 300
Flush
Flanged
Seal
CS
SS
DIN
DN80PN40
CS
SS
Wetted Materials
Construction
Diaphragm
Upper Insert
See Figure
316 LSS
Hast C
Hast C
Monel
Monel
316 LSS
Hast C
Monel
316 LSS
Hast C
Hast C
Monel
Monel
316 LSS
Hast C
Monel
316 LSS
Hast C
Hast C
Monel
Monel
316 LSS
Hast C
Monel
SS
SS
Hast C
SS
Monel
10a
N/A
10b
10a
10b
SS
SS
Hast C
SS
Monel
10a
N/A
10b
10a
10b
SS
SS
Hast C
SS
Monel
10a
N/A
10b
10a
10b
Dimension
3.5” Diaphragm
Dia. (in.)
A
B
7.50
1.10
0.94
1.10
0.94
8.25
1.31
1.12
1.31
1.12
7.87
1.07
0.94
1.07
0.94
Instrument
Connection
Upper
(Non-wetted)
A
Upper
(Non-Wetted)
Instrument
Connection
A
1.7"
B
B
Upper Insert
(Wetted)
Diaphragm
(Wetted)
Figure 10a. Flush Flanged Seal
22839
20395
Diaphragm
(Wetted)
Figure 10b. Flush Flanged Seal
34-ST-03-64
Page 33
Model Selection Guide, cont.
Type
2.4"
Diaph.
Dia. (in.)
2.9"
Diaph.
Dia. (in.)
4.1"
Diaph.
Dia. (in.)
A
B
C
… 3.50
… 2.00
… 4.00
… 1.90
… 5.30
… 2.10
A
B
C
■ 4.00
■ 1.70
■ 1.10
… 4.00
… 2.00
… 5.30
… 2.10
A
B
C
■ 5.00
■ 1.80
■ 1.20
■ 5.00
■ 1.80
■ 1.20
… 5.30
… 2.10
A
B
C
■ 6.00
■ 1.90
■ 1.40
■ 6.00
■ 1.80
■ 1.30
… 5.80
… 2.00
3"
A
B
C
■ 7.50
■ 2.30
■ 1.90
■ 7.50
■ 2.30
■ 1.90
■ 7.50
■ 2.00
■ 1.60
1"
A
B
C
■ 4.90
■ 1.90
■ 1.30
… 4.50
… 2.10
… 5.30
… 2.10
A
B
C
■ 6.10
■ 1.80
■ 1.20
■ 6.10
■ 1.80
■ 1.30
… 5.80
… 2.30
2"
A
B
C
■ 6.50
■ 1.90
■ 1.50
■ 6.50
■ 1.80
■ 1.40
■ 6.50
■ 2.30
■ 1.90
3"
A
B
C
■ 8.30
■ 2.70
■ 2.10
■ 8.30
■ 2.40
■ 1.80
■ 8.30
■ 2.30
■ 2.10
Size
1/2"
1"
150 1-1/2"
2"
Flush
Flanged
Seal
with
Lower
1-1/2"
300
Dim.
—
—
—
—
—
—
A
Instrument
Connection
Upper Insert
(Non-Wetted)
Upper
(Non-Wetted)
C
Lower
(Wetted)
Diaphragm
(Wetted)
Gasket
(Wetted)
—
B
20396
Figure 11. Flush Flanged Seal with Lower (■ )
—
—
Instrument
Connection
—
A
Bolt*
Upper
(Non-Wetted)
B
Diaphragm
(Wetted)
Gasket
Lower
(Wetted)
Stud
User Supplied
Flange and Nut
*Bolts and Upper are same material.
20397
Figure 12. Flush Flanged Seal with Lower (…)
34-ST-03-64
Page 34
Model Selection Guide, cont.
Type
Dim.
2.4"
Diaph.
Dia. (in.)
2.9"
Diaph.
Dia. (in.)
3"
150
A
B
C*
7.50
0.94
2.85
—
—
—
3"
300
A
B
C*
8.25
1.12
2.85
—
—
—
A
B
C*
7.87
0.94
2.85
—
—
—
A
B
C*
—
—
—
9.00
0.94
3.70
4"
300
A
B
C*
—
—
—
10.00
1.25
3.70
DIN
DN100PN40
A
B
C*
—
—
—
9.25
0.94
3.70
Size
DIN
Flanged
DN80Seal with
PN40
Extended
Diaphgram 4"
150
A
Instrument
Connection
Flange
(Non-Wetted)
B
Extension
Length
Raised Face
(Wetted)
Extension
(Wetted)
Diaphragm
(Wetted)
C
20398
Figure 13. Flanged Seal with Extended Diaphragm
*Designed to mate with Sch 40 pipe.
User Supplied Flange and
Bolt (3/8 -24 NF threads)
Type
Pancake
Seal
Size
Dimension
3.5" Diaph.
Dia. (in.)
3"
150/300/600
A
B
5.00
0.90
Instrument
Connection
B
Body
(Wetted)
Diaphragm
(Wetted)
A
20399
Figure 14. Pancake Seal
A
Type
Size
Dimension
3.5" Diaph.
Dia. (in.)
Chemical
Tee
"Taylor
Wedge"
Seal
750 psi
A
B
5.00
0.50
Body
(Wetted)
Diaphragm
(Wetted)
Instrument
Connection
B
20400
Figure 15. Chemical Tee "Taylor Wedge"
34-ST-03-64
Page 35
Model Selection Guide, cont.
Instrument
Connection
Type
Seal with
Threaded
Process
Connection
Size
Dim.
1/4"
or
1/2"
A
B
3/4"
or
1"
A
B
2.4"
Diaph.
Dia. (in.)
2.9"
Diaph.
Dia. (in.)
4.1"
Diaph.
Dia. (in.)
3.50
1.80
4.00
1.80
5.30
1.80
3.50
2.10
4.00
2.10
Upper
B (Non-Wetted)
Bolt
Lower
(Wetted)
5.30
2.10
Gasket
Wetted
Diaphragm
(Wetted)
A
20401
Figure 16. Seal with Threaded Process Connection
Type
Sanitary
Seal
Size
Dim.
1.9"
Diaph.
Dia. (in.)
2.4"
Diaph.
Dia. (in.)
2.9"
Diaph.
Dia. (in.)
4.1"
Diaph.
Dia. (in.)
2"
A
B
2.50
1.20
—
—
—
—
—
—
2-1/2"
A
B
—
—
3.00
1.20
—
—
—
—
3"
A
B
—
—
—
—
3.60
1.20
—
—
4"
A
B
—
—
—
—
—
—
4.7
1.0
Instrument
Connection
Body
(Wetted)
B
Diaphragm
(Wetted)
A
20402
Figure 17. Sanitary Seal
34-ST-03-64
Page 36
Model Selection Guide, cont.
A
Instrument
Connection
Bolts
Body
(Non-Wetted)
B
Lower Housing
(Wetted)
Weld
by User
Type
Saddle
Seal
Size
Dimension
2.4" Diaph.
Dia. (in.)
3"
A
B
3.50
2.30
4" or
larger
A
B
3.50
2.40
Diaphragm
(Wetted)
Gasket
(Wetted)
20403
Figure 18. 3" Saddle Seal
A
Body
(Non-Wetted)
Instrument
Connection
Bolt
B
Weld
by User
Lower Housing
(Wetted)
Diaphragm
(Wetted)
Gasket
(Wetted)
20404
Figure 19. 4" or larger Saddle Seal
ST 3000 is a registered trademark of Honeywell International Inc.
HART* is a trademark of the Hart Communication Foundation.
FOUNDATION™ is a trademark of the Fieldbus Foundation.
Industrial Measurement and Control
Honeywell International Inc.
2500 W. Union Hill Drive
Phoenix, Arizona 85027
Honeywell International Inc.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement