Performance Data Sheet
AE4460U-FZ1C
General Information
Model
AE4460U-FZ1C
Refrigerant
R-290
Test Condition
EN12900 ASERCOM
Performance Test Voltage
240V ~ 50HZ
Return Gas
20°C (68°F) RETURN GAS
Motor Type
CSIR
Performance Information
Condensing Temperature (°C)
Evap
Temp (°C)
Watts
(Capacity)
-15
675
572
411
449
482
2.91
3.01
Lb/h
11.5
11.0
11.0
10.7
1090
951
828
689
Watts (Power)
389
440
489
534
Amps
2.72
2.87
3.05
3.21
Lb/h
13.8
13.3
13.1
12.7
1240
1090
946
785
Watts (Power)
400
458
514
567
Amps
2.76
2.93
3.14
3.34
Lb/h
15.5
15.0
14.8
14.2
1320
1160
1010
840
Watts (Power)
405
466
526
583
Amps
2.78
2.97
3.19
3.40
Lb/h
16.4
15.9
15.6
15.0
1570
1390
1220
1020
Watts (Power)
416
487
559
628
Amps
2.82
3.05
3.31
3.58
Lb/h
19.1
18.7
18.4
17.7
1830
1640
1450
1220
Watts (Power)
421
502
585
667
Amps
2.84
3.10
3.42
3.75
Lb/h
21.8
21.6
21.4
20.7
1950
1750
1550
1310
420
506
594
682
(Capacity)
Watts
(Capacity)
Watts
(Capacity)
Watts
7.2
769
2.77
Watts
5
889
370
(Capacity)
0
60
2.65
Watts
-5
50
Amps
(Capacity)
-6.7
40
Watts (Power)
Watts
-10
30
(Capacity)
Watts (Power)
Amps
2.84
3.12
3.46
3.81
Lb/h
23.0
22.9
22.7
22.0
2110
1900
1690
1440
Watts (Power)
417
509
603
698
Amps
2.84
3.13
3.50
3.88
Lb/h
24.5
24.5
24.4
23.8
2380
2170
1940
1670
Watts (Power)
402
505
612
720
Amps
2.79
3.13
3.54
3.98
Lb/h
27.1
27.4
27.5
26.9
Watts
(Capacity)
10
Watts
(Capacity)
15
COEFFICIENTS
CAPACITY
POWER
CURRENT
MASS FLOW
C1
2.50113E+03
2.29605E+02
2.82959E+00
2.59150E+01
C2
5.30747E+01
-3.17057E+00
-1.13890E-03
3.75221E-01
C3
-4.79259E+01
5.10300E+00
-2.57337E-02
-4.73897E-01
C4
1.17363E-01
-1.49732E-01
-4.93620E-04
-3.27555E-03
C5
1.30418E-01
1.24210E-01
-4.96462E-05
8.27661E-03
C6
7.40627E-01
4.94275E-02
1.05728E-03
1.07788E-02
C7
-6.86543E-03
-2.28298E-03
-1.05177E-05
-1.13907E-04
C8
5.59384E-03
5.02003E-04
1.62516E-06
1.37850E-04
C9
-6.34256E-03
1.16089E-03
1.08156E-05
-8.52281E-05
C10
-5.89860E-03
-3.96557E-04
-6.97652E-06
-8.59692E-05
Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3
Te = Evaporator Temperature
Tc = Condensing Temperature

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project