Keysight FieldFox Combination Analyzers

Keysight FieldFox Combination Analyzers
Keysight
FieldFox Combination Analyzers
4/6.5/9/14/18/26.5 GHz
Technical
Overview
N9913A
N9914A
N9915A
N9916A
N9917A
N9918A
Get Keysight-Quality Microwave Measurements in
the Field
Every piece of gear in your ield kit had to prove its worth. Measuring up and earning
a spot is the driving idea behind Keysight’s FieldFox microwave analyzers. They’re
equipped to handle routine maintenance, in-depth troubleshooting and anything in
between. Better yet, FieldFox delivers Keysight-quality microwave measurements—
wherever you need to go.
On land, sea and air, FieldFox is ready for a wide range of applications: satellite communications, microwave backhaul, military communications, radar systems, and more.
In harsh conditions and hard-to-reach locations, FieldFox delivers precise results that
are consistent with those you’d see on a benchtop analyzer. To get you out of the elements sooner, the task-driven user interface will help you inish the job faster.
For maximum functionality, FieldFox analyzers integrate the microwave capabilities
you need in a single, compact instrument. They also give you—and your budget—more
lexibility: conigure an instrument with the features you need today and add others in
the future.
Cable and antenna analyzer
– Cable fault location and identiication with distance-to-fault (DTF) and time-domain
relectometry (TDR)
– Return loss, VSWR and cable loss (1-port and 2-port)
– Integrated QuickCal – no calibration kit required
– 30 kHz to 26.5 GHz
Spectrum analyzer
– Unprecedented amplitude accuracy (± 0.5 dB) with InstAlign 1 – no warm up
required
– Tracking generator, independent source, and preampliier covering the full frequency
range
– 5 kHz to 26.5 GHz
Vector network analyzer (VNA)
–
–
–
–
1.
All four S-parameters, magnitude and phase
Guided Calibration Wizard, full 2-port cal, TRL, waveguide calibration
Mixed-mode relection S-parameters
30 kHz to 26.5 GHz
With FieldFox InstAlign, internal amplitude alignments occur automatically as environmental conditions change, without any user intervention.
03 | Keysight | FieldFox Combination Analyzers - Technical Overview
Add the World’s Most Precise Handheld Microwave Analyzer to Your Kit
Tracking generator and
built-in independent
signal source
Pulse measurements
using a USB peak power sensor
– CW, CW coupled, and
tracking
– Flat output power across
whole frequency span, in 1
dB steps
– 30 kHz to 26.5 GHz
– Measure peak power,
average power and peak to
average ratio
– Pulse proile characterization with gating
– 50 MHz to 40 GHz
(frequency range sensor
dependent)
Built-in power meter
– Easy to view analog and
digital display
– ± 0.5 dB accuracy with
InstAlign
– 5 kHz to 26.5 GHz
CW and swept-frequency power measurements with USB
power sensor
– Measure power at a CW
frequency
– Measure power versus frequency, including frequency-offset
– Frequency and power
range dependent on USB
power sensor
Vector voltmeter
– Cable trimming, phase
shift and electrical length
measurements
– A/B and B/A ratio measurements
– 30 kHz to 26.5 GHz
Extended range transmission analysis (ERTA)
– Measure long lossy in-situ
cables using two synchronized FieldFoxes
– Measure converters using
ERTA’s frequency-offset
capability
04 | Keysight | FieldFox Combination Analyzers - Technical Overview
Designed For You and the Work You Do Everyday
Carry FieldFox wherever you need to go
Kit friendly 3.0 kg or 6.6 lbs
Large buttons are easy to operate, even when wearing gloves
Field swappable battery lasts up to 3 1/2 hours
Non-slip rubber grip securely its in your hands and won’t slide off the hood of your
vehicle
– Vertical “portrait” orientation makes it easy to hold and operate at the same time
–
–
–
–
Field-proof usability for better answers in less time
– Bright, low-relection display and backlit keys enable easy viewing in direct sunlight
or darkness
– Intuitive user interface is designed for your worklow, enabling measurements in
fewer key presses
– One-button measurements simplify complex setups and ensure quick, accurate
results with conidence
– Calibration Wizard guides user to ensure simple and accurate calibrations
– 3-year warranty ensures ield conidence - especially in harsh environments
Translective display makes it easy to read
measurements in direct sunlight
Large buttons make it easy to perform
spectrum analysis measurements – even
with gloves on
05 | Keysight | FieldFox Combination Analyzers - Technical Overview
Rugged Enough to Meet MIL-Specs
– Completely sealed instrument enclosure provides measurement stability in harsh
environments
– Specially designed connector bay protects RF connectors from damage due to drops
or other external impacts (designed to withstand 4’ drop on concrete surface on all
6 faces)
– Water-resistant chassis, keypad and case withstand wide temperature ranges and
salty, humid environments
– Case withstands shock and vibration
– Wide operating temperature -10 to +55 ºC (14 to 131 ºF)
– Wide storage temperature -51 to +71 ºC (-60 to 160 ºF)
– Meets MIL-PRF-28800F Class 2 requirements
– Type tested and meets MIL-STD-810G, Method 511.5, Procedure I requirements for
operation in explosive environments
– Meets IEC/EN 60529 IP53 requirements for protection from dust and water
Dust-free design with no vents or fans
helps extend instrument reliability
06 | Keysight | FieldFox Combination Analyzers - Technical Overview
Pick Up FieldFox For Its Ergonomics
4
11.5” (292 mm)
1
5
2
3
7.4” (188 mm)
Number Description
Portrait design and large buttons for easy operation – even with gloves on
1
Convenient side strap makes it easy to hold and carry
2
Task-driven keys are grouped to easily perform ield measurements
3
Dedicated marker keys for quick marker function access
4
Anti-glare 6.5 inch LCD display with LED backlight
5
Backlit keypad
07 | Keysight | FieldFox Combination Analyzers - Technical Overview
…and Depend On Its Durability and Convenience
Top view
Number
1
2
3
4
5
6
Description
Connector bay protects RF connectors
Port 1/RF output
Get precise location using the built-in
GPS receiver
External reference and external trigger
input
Port 2/SA RF input
Quick connect shoulder strap clips
1
2
3
4
5
6
Right side
1
2
3
4
5
7
6
Number Description
1
Keep going with ield-swappable batteries that last up to 3 1/2 hours
2
LAN port for data transfer and SCPI
programming
3
Spectrum analyzer 25 MHz IF out
usable for signal analysis
4
External reference and data storage
external trigger output
5
SD lash card for data storage
6
USB ports for easy data storage
7
Gasketed doors protect ports from
moisture
Left side
1
2
Number Description
1
Simplify interference analysis with
AM/FM tune and listen
2
Built-in DC supply for powering
external bias-tees, probes, and active
devices
08 | Keysight | FieldFox Combination Analyzers - Technical Overview
Cable and Antenna Analyzer
Fifty to sixty percent of microwave-link equipment issues are related to cables, antennas
and connectors. Degraded feeder lines cause poor coverage, link failures, and reduced
sensitivity on the receive path. To maintain the quality of a microwave link, it is critical
to keep the cable and antenna systems in good working condition. FieldFox is uniquely
qualiied to provide all the necessary measurements to troubleshoot and maintain these
systems.
Measurements:
– Insertion loss (2-port, when both ends are accessible) and cable loss (1-port, when
only a single port is easily accessible)
– Insertion loss or cable loss characterizes the loss of a jumper cable, feeder cable,
diplexer, or gain of a tower-mounted ampliier (TMA). Also, FieldFox’s ERTA option,
described on page 11, is useful for measuring long lossy in-situ cables.
Return loss and DTF display
– Return loss or VSWR
– Return loss / VSWR is the single most important parameter to measure and verify
a cable and antenna system. This measurement relects the power transfer
eficiency of a given system.
– Distance-to-fault (DTF) and time-domain relectometry (TDR)
– DTF helps users determine the location of discontinuities in feeder lines. TDR
helps users determine the nature of the discontinuities, for example, a short,
open, or water ingress.
With FieldFox, users can make both RL and DTF measurements at the same time. This
helps technicians correlate overall system degradation with speciic faults in the cable
and antenna system. The built-in cable editor allows users to edit existing cable types
on-site, and save them as new cable types with user deined names.
Filter insertion loss display
Measure both DTF and TDR in single sweep
Additionally, FieldFox’s TDR complements RL and DTF measurements. TDR measures
impedance changes along the cable and helps identify speciic faults, while RL exposes
mismatch issues and DTF indicates faults and poor connections. FieldFox is the only
handheld instrument that can measure both DTF and TDR in a single sweep.
Gain insight into faults with TDR measurements
09 | Keysight | FieldFox Combination Analyzers - Technical Overview
Cable and Antenna Analyzer (continued)
CalReady-calibrated at power on and ready to go
Save time and get right to work with FieldFox’s CalReady feature. With CalReady, the analyzer is already calibrated and ready to make measurements such as S11, S22, 1-port cable
loss, and DTF measurements without having to connect/disconnect additional calibration
devices.
Hassle-free calibration in the ield with the industry’s irst and only
QuickCal
FieldFox is the industry’s irst and only handheld network analyzer with a built-in calibration
capability that allows you to calibrate the network analyzer without carrying a calibration
kit (cal kit) into the ield.
Step 1. FieldFox’s QuickCal allows you to
perform calibrations without carrying a cal
kit
With any other test instrument, when you add additional devices to the test port, such as
jumper cables or adapters, you need to recalibrate using a cal kit. FieldFox’s QuickCal supports measurements such as insertion loss/gain, 1-port cable loss, return loss, and DTF.
Broadband calibration
FieldFox allows you to make broadband calibrations, which means the instrument is calibrated over the maximum frequency range. After a broadband calibration, you can change
the frequency range or number of points without recalibrating the instrument. The calibration is interpolated, and accuracy is maintained.
User cal kit support
Step 2
For users who wish to use traditional mechanical calibration kits, FieldFox supports most
HP/Agilent/Keysight cal kits, and also allows you to deine your own custom calibration kits.
Fast and accurate calibration with ECal
The FieldFox calibration engine supports Keysight’s USB ECal modules. ECal support
reduces calibration time and the need to make multiple connections during testing, while
also providing for greater consistency between measurements. For FieldFox users, that
translates into fewer human errors and increased accuracy.
Step 3
10 | Keysight | FieldFox Combination Analyzers - Technical Overview
Spectrum Analyzer
Spectrum analyzer
In microwave, radar, and satellite communications, and commercial microwave backhaul,
engineers are responsible not only for hardware installation and maintenance, but also
over-the-air signal quality. They need to regularly monitor for rogue signals and perform
signal surveillance.
FieldFox’s spectrum analyzer is optimized to excel in the dynamic spectral environment
seen commonly in the ield. In the ield, users face measurement challenges such as the
need to detect a low-level signal under strong signal conditions (requiring high dynamic
range), or close-in small interference signals (requiring excellent phase noise).
Monitor the spectrum using the FieldFox
analyzers
FieldFox’s superior dynamic range (TOI > +15 dBm), close in phase noise (—111 dBc/Hz at
10 kHz), and fast sweep time make these challenging tasks easier. FieldFox’s spectrum
analyzer also provides a full power measurement suite and complete trace and state
control.
Unprecedented amplitude accuracy without instrument warm up –
InstAlign
With FieldFox InstAlign, internal amplitude alignments occur automatically as the environmental conditions change, without any user intervention. This provides unprecedented amplitude accuracy up to ± 0.5 dB for spectrum analysis and power measurements.
Better yet, FieldFox provides this accuracy immediately upon instrument turn on – no
warm up required.
Spectrum analyzer time gating
FieldFox’s time gating is designed for engineers testing the pulse characteristics of their
radar systems. FieldFox’s gated FFT time gating allows for signals with pulse widths as
narrow as 8 μs to be measured. Triggering functions such as burst trigger and pre-trigger delay further ease pulse signal measurements.
IF signal output
FieldFox provides a spectrum analyzer IF output with 25 MHz bandwidth for use as a
frequency down-converter, and to perform wideband signal analysis.
Analyze pulsed-RF signals using the
spectrum analyzer time gating option
11 | Keysight | FieldFox Combination Analyzers - Technical Overview
Spectrum Analyzer (continued)
Field strength measurements
To characterize the electric and magnetic ields, the gain and loss of the antenna and
cables need to be accounted for. With FieldFox, antenna factors and cable loss data can
be loaded using either the front panel or the complimentary Data Link software.
Interference analyzer
Interference can be internal or external, uplink or downlink, and has a direct impact on
the Quality of Service of a communication network. FieldFox’s interference analyzer
is designed to identify interfering signals quickly. Spectrogram and waterfall displays
detect intermittent signals or monitor signals over a period of time. Signal traces can be
recorded into internal memory or external lash memory devices, and the saved traces
can be played back for ofline processing. It has excellent dynamic range with very fast
sweep times under narrow resolution bandwidths (RBWs).
Use the internal microwave signal source
for transponder testing
Independent signal source
FieldFox has a built-in independent signal source, with a frequency range of 30 kHz to
26.5 GHz. The signal source can be tuned to any frequency, independent of the spectrum
analyzer frequency. The signal source can be used to create a test signal to measure
coverage, antenna isolation, antenna direction alignment, shielding effectiveness, and
frequency offset device veriication.
Extended range transmission analysis (ERTA)
Waterfall display makes interference hunting easier
Measuring long in-situ microwave cables such as those on ships is a challenging task,
and requires instruments with high dynamic range and fast measurement speed. These
measurements were traditionally done using benchtop scalar analyzers, which are cumbersome to operate in the ield. Using FieldFox’s ERTA, users can measure dynamic ranges of 108 dB (at 6 GHz) or 77 dB (at 26.5 GHz), with a portable analyzer that requires no
calibration and no warm-up.
ERTA uses two FieldFoxes, one deployed at each end of the cable. One FieldFox acts as a
source, while the other acts as a receiver. By taking advantage of Keysight’s proprietary
InstAlign technique, this coniguration can be used to make cable loss measurements
with accuracy of ± 0.7 dB.
Measure long lossy cables using ERTA
12 | Keysight | FieldFox Combination Analyzers - Technical Overview
Vector Network Analyzer
Vector network analyzer
FieldFox’s Option 210 provides vector transmission and relection measurement (T/R), or
S11 and S21, with magnitude and phase. Adding Option 211 (full 2-port S-parameters)
brings new levels of accuracy and convenience for testing microwave components.
With a full 2-port network analyzer, you can measure the forward and reverse characteristics of your component without having to disconnect, turn around, and reconnect
it to the analyzer. The full 2-port calibration gives you the best measurement accuracy
possible.
FieldFox’s four independent, sensitive receivers provide 94 dB of dynamic
range for measurement of high rejection, narrowband devices such as
cavity ilters. The receivers also enable full 2-port error correction with the
unknown thru method, allowing users to measure non-insertable devices
accurately and easily.
FieldFox’s calibration engine is the same engine that powers the well-respected Keysight ENA and PNA network analyzers. FieldFox leverages Keysight microwave expertise to deliver consistent measurements with Keysight
benchtop VNAs.
Simultaneously measure and view all four
S-parameters, with a single connection
Port 1
Port 2:
SA RF input
Network
analyzer
receivers
A
B
R1
R2
Calibrations
FieldFox’s guided Cal Wizard takes guessing out of calibration and
allows you to easily perform the following calibrations:
– Full 2-port
– OSL, response, enhanced response
– TRL, LRL, offset short
Microwave source
FieldFox microwave analyzer architecture
Spectrum
analyzer
receiver
SA
13 | Keysight | FieldFox Combination Analyzers - Technical Overview
Vector Network Analyzer (continued)
Network analyzer time domain
With the time domain option, FieldFox computes the inverse fourier transform of the
frequency-domain data to display relection or transmission coeicients versus time. Time
domain gating can be used to remove unwanted responses such as connector mismatch
or cable discontinuities, and the results can be displayed in either time or frequency
domain.
Waveguide support
Waveguides are widely used to provide transmission links between microwave transmitters and antennas, as waveguides have less loss than coax. Keysight offers both
high-performance and also economical waveguide calibration kits. The economical kits
are ideal for ield maintenance and troubleshooting, as they provide good measurement
results at lower costs.
Time domain measurements provide insight
into the device under test
Vector voltmeter
Using FieldFox’s vector voltmeter (VVM), the phase shift and electrical length of a device
can be measured. You can view results on the large display as far as ten feet or three
meters away. VVM also provides ratio measurements of magnitude and phase of two
channels, A/B or B/A. You can use this capability to verify the magnitude and phase
differences between multiple signal paths such as in an antenna or phased array.
FieldFox offers all the key functionalities of the HP 8508A, in a handheld form factor, and
without the need for the source/bridge/accessories required with HP 8508A.
Vector voltmeter used for cable trimming
Mixed-mode S-parameters
With FieldFox, you can measure the common and differential mode relections of a
device. Mixed-mode S-parameters are also known as balanced measurements. This
measurement requires the full 2-port VNA and 2-port cal functionality.
Mixed-mode S-parameter measurements
with FieldFox
14 | Keysight | FieldFox Combination Analyzers - Technical Overview
Completing the All-In-One
Built-in power meter
By leveraging InstAlign technology, FieldFox is able to make very accurate channel power
measurements. The channel bandwidth can be set wide to simulate average power meter
measurements. This measurement function provides the lexibility to make user deinable
channel power measurements with accuracy up to ± 0.5 dB.
USB power sensor support
FieldFox can connect with the Keysight USB power sensors to make microwave power
measurements. Using USB peak power sensors, users can measure both the average and
the peak power of a modulated signal.
Easily measure power levels using the builtin channel power meter
USB power measurements versus frequency
In addition to power measurements at a single CW frequency, users can measure power
versus frequency, a swept measurement. FieldFox’s source frequency can be set equal
to the sensor/receiver frequency, or with an offset. The frequency of both the source and
receiver are swept, and the two track each other. The offset frequency can be negative,
zero, or positive.
This capability is useful for characterization of the scalar transmission response of devices such as mixers and converters. The FieldFox source stimulates the DUT and the power
sensor is used as the measurement receiver.
Characterize mixers with FieldFox and a
USB power sensor
Use FieldFox to characterize pulses
Pulse measurements
FieldFox’s pulse measurement option allows users to eficiently characterize pulsedRF signals such as those used in radar and electronic warfare systems, leveraging the
Keysight USB peak power sensors (available in 18 and 40 GHz models). Measurements
include peak power, peak to average ratio, and pulse proile parameters such as rise
time, fall time and pulse repetition frequency.
Characterize mixers with FieldFox and a
USB power sensor
15 | Keysight | FieldFox Combination Analyzers - Technical Overview
Completing the All-In-One (continued)
Remote control capability with iPad or iPhone
Engineers and technicians can now remotely monitor and control their FieldFox using
their iOS device such as an iPhone, iPad, or iPod Touch. FieldFox’s Remote Viewer iOS
app emulates the front panel of the unit, so users can simply press any FieldFox key right
from their iOS device. The app also allows users to instantly access technical documents
such as data sheets.
FieldFox’s Data Link software makes report generation and
documentation easier
FieldFox’s complimentary Data Link software provides data transfer, data deinition and
report generation. Markers and limit lines can be added to the traces. Cable iles and
antenna factors can also be loaded using Data Link.
Control and view your FieldFox via your iPad
Remote control via LAN and FieldFox programming
FieldFox analyzers are fully SCPI compliant and can be controlled over the LAN.
Built-in GPS
A built-in GPS receiver provides geolocation tags to measurements. The geo data – time,
latitude, longitude, and elevation – can be displayed and saved in data iles. In addition
to location information, the GPS provides an accurate frequency reference to improve
accuracy.
Use the complimentary Data Link software
to generate reports
Built-in variable voltage DC bias
FieldFox has a built-in variable voltage DC bias source. The source provides 1 to 32 VDC
with maximum current of 650 mA and 8 W maximum power.
The DC bias source can provide DC power to ampliiers under test and bias tower
mounted ampliiers (TMA) when engineers need to sweep through the TMA to reach the
antenna (bias-tees available separately).
Use the built-in GPS to obtain geo-location
data
16 | Keysight | FieldFox Combination Analyzers - Technical Overview
Speciications In Brief
See the FieldFox Handheld Analyzer Data Sheet for a complete listing of the speciications:
http://literature.cdn.keysight.com/litweb/pdf/5990-9783EN.pdf
See FieldFox Coniguration Guide for option information. Many capabilities listed in this Data Sheet
require options.
Cable and antenna analyzer and vector network analyzer
Models
N9913A
N9914A
N9915A, N9925A
N9916A, N9926A
N9917A, N9927A
N9918A, N9928A
Data points or resolution
System impedance
Test port output power
Frequency
30 kHz to 300 kHz
> 300 kHz to 2 MHz
> 2 MHz to 625 MHz
> 625 MHz to 3 GHz
≥ 3 to 6.5 GHz
≥ 6.5 to 9 GHz
≥ 9 to 14 GHz
≥ 14 to 18 GHz
≥ 18 to 23 GHz
≥ 23 to 26.5 GHz
Power level accuracy
Power range
Power step size
Frequency range
30 kHz to 4 GHz
30 kHz to 6.5 GHz
30 kHz to 9 GHz
30 kHz to 14 GHz
30 kHz to 18 GHz
30 kHz to 26.5 GHz
101, 201, 401, 601, 801, 1001, 1601, 4001, 10,001
Arbitrary number of points settable through SCPI
50 Ω (nominal), 75 Ω with appropriate adapter and calibration kit
Port 1 or port 2, high power, 23 ± 5 °C
Typical
—11 dBm
—3 dBm
—2 dBm
+1 dBm
—1 dBm
—2 dBm
—4 dBm
—6 dBm
—10 dBm
—12 dBm
± 1.5 dB at —15 dBm (typical)
CAT: High, low and manual. Low power is —45 dBm (nominal)
VNA: High, low and manual. Low power is —45 dBm (nominal)
Flat power, in 1 dB steps, is available across the whole frequency span (nominal)
17 | Keysight | FieldFox Combination Analyzers - Technical Overview
Speciications In Brief (continued)
System dynamic range 1: Port 1 or port 2, high power, 300 Hz IF bandwidth, —10 to 55 °C
Frequency
Spec
Typical
95 dB
100 dB
> 300 kHz to 9 GHz 2
≥ 9 to 14 GHz
91 dB
97 dB
≥ 14 to 18 GHz
90 dB
94 dB
≥ 18 to 20 GHz
87 dB
90 dB
≥ 20 to 25 GHz
74 dB
79 dB
> 25 to 26.5 GHz
65 dB
70 dB
Trace noise 3: Port 1 or port 2, high power, 300 Hz IF bandwidth, spec, —10 to 55 °C
Frequency
Magnitude
Phase
> 300 kHz to 10 GHz
± 0.002 dB (rms)
± 0.014 degrees
> 10 to 20 GHz
± 0.004 dB (rms)
± 0.027 degrees
> 20 to 26.5 GHz
± 0.010 dB (rms)
± 0.066 degrees
Measurements
CAT
Distance-to-fault (dB), return loss, VSWR, distance-to-fault (VSWR), cable loss (1-port), insertion loss
(2-port) 4, distance-to-fault (linear or Rho)
VNA T/R
S11, S21 5
VNA S-parameters
S11, S21, S22, S12 6
Connectors
Type-N 50 Ω, Type-N 75 Ω, 7/16, TNC, 3.5 mm, 2.4 mm, waveguide bands: X-band WR-90, P-band WR62, K-band WR-42. Custom coaxial or waveguide calibration kits can be added to any FieldFox analyzer.
1. For CAT mode “Insertion loss (2-port)”, decrease listed dynamic range speciications by 20 dB, as CAT mode IFBW is ixed at 10 kHz. Can obtain full dynamic
range by using S21 measurement in VNA mode with 100 Hz IFBW.
2. < 300 kHz, 63 dB (nominal), 2 MHz to 9 MHz: 85 dB spec, 90 dB typical
3. For CAT mode, increase trace noise by a factor of 5.7, as CAT mode IFBW is ixed at 10 kHz. Can use averaging in CAT mode to reduce trace noise, or use
VNA mode with 300 Hz IFBW.
4. All measurements standard are on N991xA analyzers except insertion loss (2-port). Insertion loss (2-port) requires Option 210. All measurements are available on N992xA analyzers with Option 305.
5. Standard on N992x VNAs. Option 210 required on N991xA analyzers.
6. Option 211 required to obtain all four S-parameters.
18 | Keysight | FieldFox Combination Analyzers - Technical Overview
Speciications In Brief (continued)
Vector voltmeter (VVM)
Models
Frequency range
N9913A
30 kHz to 4 GHz
N9914A
30 kHz to 6.5 GHz
N9915A, N9925A
30 kHz to 9 GHz
N9916A, N9926A
30 kHz to 14 GHz
N9917A, N9927A
30 kHz to 18 GHz
N9918A, N9928A
30 kHz to 26.5 GHz
Spectrum analyzer
Models
Frequency range
N9913A
100 kHz to 4 GHz
Usable to 5 kHz
N9914A
100 kHz to 6.5 GHz
Usable to 5 kHz
N9915A, N9935A
100 kHz to 9 GHz
Usable to 5 kHz
N9916A, N9936A
100 kHz to 14 GHz
Usable to 5 kHz
N9917A, N9937A
100 kHz to 18 GHz
Usable to 5 kHz
N9918A, N9938A
100 kHz to 26.5 GHz
Usable to 5 kHz
The spectrum analyzer is tunable to 0 Hz or DC.
The preampliier covers the full band with nominal gain of 20 dB.
Frequency reference: —10 to 55 ºC
Accuracy
± 0.7 ppm (spec) + aging
± 0.4 ppm (typical) + aging
Accuracy, when locked to GPS
± 0.025 ppm (spec)
Aging rate
± 1 ppm/yr for 20 years (spec), will not exceed ± 3.5 ppm
Frequency span
Spec
Resolution
1 Hz
Spec
Resolution bandwidth (RBW)
Zero span: 10 Hz to 5 MHz
Range (—3 dB bandwidth)
Non-zero span: 1 Hz to 5 MHz
Video bandwidth (VBW)
1 Hz to 5 MHz
Non-zero span: 1, 1.5 ,2, 3, 5, 7.5, 10 sequence
Zero span: RBW/VBW ≤ 100
19 | Keysight | FieldFox Combination Analyzers - Technical Overview
Speciications In Brief (continued)
Phase noise: Stability, SSB phase noise at 1 GHz
Offset
Spec (23 ± 5 ºC)
Spec (—10 to 55 ºC)
Typical (23 ± 5 ºC)
Typical (—10 to 55 ºC)
10 kHz
—106 dBc
—106 dBc
—111 dBc
—111 dBc
30 kHz
—106 dBc
—104 dBc
—108 dBc
—110 dBc
100 kHz
—100 dBc
—99 dBc
—104 dBc
—105 dBc
1 MHz
—110 dBc
—110 dBc
—113 dBc
—113 dBc
3 MHz
—119 dBc
—118 dBc
—122 dBc
—122 dBc
5 MHz
—120 dBc
—120 dBc
—123 dBc
—123 dBc
Displayed average noise level (DANL): RMS detection, log averaging, reference level of —20 dBm, normalized to 1 Hz RBW
Preamp on
Spec (23 ± 5 ºC)
Spec (—10 to 55 ºC)
Typical (23 ± 5 ºC)
Typical (—10 to 55 ºC)
—153 dBm
—151 dBm
—155 dBm
—154 dBm
2 MHz to 4.5 GHz 1
> 4.5 to 7 GHz
—149 dBm
—147 dBm
—151 dBm
—150 dBm
> 7 to 13 GHz
—147 dBm
—145 dBm
—149 dBm
—148 dBm
> 13 to 17 GHz
—143 dBm
—141 dBm
—145 dBm
—144 dBm
> 17 to 22 GHz
—140 dBm
—139 dBm
—143 dBm
—142 dBm
> 22 to 25 GHz
—134 dBm
—132 dBm
—137 dBm
—134 dBm
> 25 to 26.5 GHz
—128 dBm
—126 dBm
—131 dBm
—129 dBm
50 MHz absolute amplitude accuracy
50 MHz, veriied with input level of 0 to —35 dBm, peak detector, 10 dB attenuation, preampliier off, 30 kHz
RBW, all settings auto-coupled, no warm-up required, —10 to 55 ºC
± 0.3 dB (spec)
± 0.10 dB (typical)
Total absolute amplitude accuracy
Veriied with input level of —5 dBm. Peak detector, 10 dB attenuation, preampliier off, 30 kHz RBW, all settings auto-coupled, no warmup required.
Includes frequency response uncertainties.
Spec (23 ± 5 ºC)
Spec (—10 to 55 ºC)
Typical (23 ± 5 ºC)
Typical (—10 to 55 ºC)
100 kHz to 18 GHz
± 0.8 dB
± 1.0 dB
± 0.35 dB
± 0.50 dB
> 18 GHz to 26.5 GHz
± 1.0 dB
± 1.2 dB
± 0.50 dB
± 0.60 dB
Third order intermodulation distortion (TOI)
Two —20 dBm signals, 100 kHz spacing at input mixer,
Spec
Typical
—10 to 55 °C
At 2.4 GHz, +15 dBm
< 1 GHz, +10 dBm
1 to 7.5 GHz, +15 dBm
> 7.5 GHz, +21 dBm
1.
Increase the noise loor 4 dB for frequencies between 2.1 and 2.8 GHz.
20 | Keysight | FieldFox Combination Analyzers - Technical Overview
Speciications In Brief (continued)
Tracking generator or independent source
Model
N9913A
N9914A
N9915A, N9935A
N9916A, N9936A
N9917A, N9937A
N9918A, N9938A
Dynamic range: Typical, —10 to 55 ºC
Frequency
2 MHz to 2 GHz
> 2 to 7 GHz
> 7 to 11 GHz
> 11 to 16 GHz
> 16 to 21 GHz
> 21 to 23 GHz
> 23 to 25 GHz
> 25 to 26.5 GHz
Built-in power meter
Models
N9913A
N9914A
N9915A, N9925A, N9935A
N9916A, N9926A, N9936A
N9917A, N9927A, N9937A
N9918A, N9928A, N9938A
Tracking generator or independent source frequency range
30 kHz to 4 GHz
30 kHz to 6.5 GHz
30 kHz to 9 GHz
30 kHz to 14 GHz
30 kHz to 18 GHz
30 kHz to 26.5 GHz
Preamp off
97 dB
93 dB
88 dB
79 dB
71 dB
55 dB
50 dB
45 dB
Preamp on
112 dB
108 dB
103 dB
94 dB
86 dB
70 dB
65 dB
60 dB
Frequency range
100 kHz to 4 GHz
100 kHz to 6.5 GHz
100 kHz to 9 GHz
100 kHz to 14 GHz
100 kHz to 18 GHz
100 kHz to 26.5 GHz
Usable to 5 kHz
Usable to 5 kHz
Usable to 5 kHz
Usable to 5 kHz
Usable to 5 kHz
Usable to 5 kHz
Amplitude accuracy
100 kHz to 18 GHz
> 18 GHz to 26.5 GHz
General information
Calibration cycle
Weight
Dimensions: H x W x D
Environmental
MIL-PRF-28800F Class 2
MIL-STD-810G, Method 511.5
Altitude – operating
Altitude – non-operating
Complies with European EMC directive
Battery
Warranty
Spec (23 ± 5 ºC)
± 0.8 dB
± 1.0 dB
Typical (23 ± 5 ºC)
± 0.35 dB
± 0.50 dB
Spec (-10 to 55 ºC)
± 1.0 dB
± 1.2 dB
Typical (—10 to 55 ºC)
± 0.50 dB
± 0.60 dB
1 year
3.0 kg or 6.6 lbs including battery
292 x 188 x 72 mm (11.5” x 7.4” x 2.8”)
Operating temperature
Storage temperature
Operating humidity
Random vibration
Functional shock
Bench drop
Type tested and meets Procedure I requirements for operation in explosive environments
9144 m or 30,000 ft (using battery)
15,240 m or 50,000 ft
IEC/EN 61326–1
CISPR Pub 11 Group 1, class B, Group 1 limit of CISPR 11:203/EN
55011:2007
AS/NZS CISPR 11
ICES/NMB–001
Lithium ion, 10.8 V, 4.6 A-h, 3.5 hours (typical)
3-year warranty standard on all FieldFox instruments
21 | Keysight | FieldFox Combination Analyzers - Technical Overview
Coniguration Information in Brief
See the FieldFox Coniguration Guide for complete information on all FieldFox products and accessories.
http://literature.cdn.keysight.com/litweb/pdf/5990-9836EN.pdf
Model
N9913A
N9914A
N9915A
N9916A
N9917A
N9918A
Options
Base unit for N9913/4/5/6/7/8A
analyzers
Option 010 (requires Option 210, recommend 211)
Option 030
Option 112
Option 208 (requires Option 302)
Option 209 (requires Options 210 and 233,
and two FieldFoxes)
Option 210
Option 211 (requires Option 210)
Option 212 (requires Option 211)
Option 215 TDR cable measurements
Option 233
Option 235 (requires Option 233)
Option 236 (requires Option 233)
Option 238 (requires Option 233)
Option 302
Option 307
Option 308 (for A/B and B/A, requires
Option 210 and Option 211)
Option 309
Option 310
Option 330
Description
FieldFox RF combination analyzer, 4 GHz
FieldFox RF combination analyzer, 6.5 GHz
FieldFox microwave combination analyzer, 9 GHz
FieldFox microwave combination analyzer, 14 GHz
FieldFox microwave combination analyzer, 18 GHz
FieldFox microwave combination analyzer, 26.5 GHz
Descriptions
Cable and antenna analyzer
Test port connector
Type-N (f) test ports, 50 ohm
Type-N (f) test ports, 50 ohm
Type-N (f) test ports, 50 ohm
Type-N (f) test ports, 50 ohm
Type-N (f) test ports, 50 ohm
3.5 mm (m) test ports, 50 ohm
Measurements /functions
VSWR, distance-to-fault, Cable loss (1-port),
Insertion loss (2-port, requires Option 210)
Vector network analyzer time domain
Time domain and distance domain data
Gating/windowing
Remote control capability
Remote viewing and control using iPhone, iPad or
iPod Touch
QuickCal
Calibration without using external calibration kit
USB power sensor measurements versus frequency
Includes frequency offset capability
Extended range transmission analysis (ERTA, or
Transmission measurement over long distances,
FoxTrot)
with frequency offset
Vector network analyzer – transmission and relection S11, S21 magnitude and phase
Response cal and enhanced response cal
Vector network analyzer – full 2-port S-parameters
Adds reverse S-parameters, S12 and S22, and full
2-port
Mixed-mode S-parameters
Scc11, Sdd11, Scd11, Sdc11
TDR (lin rho), TDR (ohm)
Spectrum analyzer
Spectrum analyzer, independent source
CHP, ACPR, OBW, ield strength measurements
Preampliier
20 dB gain nominal
Interference analyzer and spectrogram
Spectrogram and waterfall display
Record / playback
Spectrum analyzer time gating
Analyze pulsed signals
External USB power sensor support
Requires Keysight U2000 series power sensor
GPS receiver (receiver built-in, external antenna
Geo location information
required)
Lock internal reference to GPS
Vector voltmeter
Cable trimming, 2-port transmission, A/B and B/A
DC bias variable-voltage source
Built-in power meter
Pulse measurements
+1 to 32 VDC for external bias-tee and other devices
Built-in power measurement, using the built-in
receiver without a power sensor
Requires Keysight USB peak power sensor
22 | Keysight | FieldFox Combination Analyzers - Technical Overview
FieldFox Analyzers
Spectrum analysis
Cable and antenna analysis
Vector voltmeter measurements
Built-in power meter
Vector network analysis
Interference analysis
Channel power measurement
Tracking generator
FieldFox
Model number
Maximum frequency range
Cable and antenna analyzer
Vector network analyzer
Mixed-mode S-parameters
Spectrum analyzer
Interference analyzer
Tracking generator
Independent source
Vector voltmeter
Built-in power meter
Power meter with USB sensor
USB power sensor measurements versus frequency
Pulse measurements
Remote control using iOS device
Extended range transmission analysis
TDR cable measurements
RF & microwave
combination analyzers
N9913/4/5/6/7/8A
4, 6.5, 9, 14, 18, 26.5 GHz
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Microwave vector
network analyzers
N9925/6/7/8A
9, 14, 18, 26.5 GHz
√
√
√
Microwave
spectrum analyzers
N9935/6/7/8A
9, 14, 18, 26.5 GHz
VSWR and relection
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
23 | Keysight | FieldFox Combination Analyzers - Technical Overview
Accessories
The accessories shown here are a subset of the available accessories. For a complete list, visit www.keysight.com/ind/n9910x
Description
N9910X-709
Phase stable cable
– 3.5 mm(f) to 3.5 mm(f)
– 26.5 GHz
N9910X-810
Phase stable cable
– Type-N(m) to Type-N(m)
– 6 GHz
Instrument
Description
N990X-873
AC/DC adaptor
N9910X-874
Bias-tee
N9910X-845
Adaptor kit
N9910X-860
Fixed attenuator
– 40 dB
– 100 W
N9910X-870
Extra battery
N9910X-875
DC car charger and adapter
N9910X-881
Hard transit case
– FieldFox its inside hard
transit case
N9910X-872
External battery charger
N9910X-880
Soft transit case
– Comes standard with each
FieldFox
– Includes backpack and
shoulder straps
Instrument
24 | Keysight | FieldFox Combination Analyzers - Technical Overview
Accessories (continued)
The accessories shown here are a subset of the available accessories. For a complete list, visit www.keysight.com/ind/n9910x
Description
N9910X-800
3-in-1
– OSL
– 6 GHz
– Type-N(m)
– 50 ohm
Instrument
Description
85520A
4-in-1
– OSLT
– 26.5 GHz
– 3.5mm (m)
– 50 ohm
85515A
4-in-1
– OSLT
– 9 GHz
– Type-N(f)
– 50 ohm
85518A
4-in-1
– OSLT
– 18 GHz
– Type-N(m)
– 50 ohm
85521A
4-in-1
– OSLT
– 26.5 GHz
– 3.5mm (f)
– 50 ohm
N9910X-820
Directional antenna
85519A
4-in-1
– OSLT
– 18 GHz
– Type-N(f)
– 50 ohm
N9910X-821
Telescopic whip antenna
Instrument
25 | Keysight | FieldFox Combination Analyzers - Technical Overview
Carry Precision With You
Every piece of gear in your ield kit had to prove its worth. Measuring up and earning a spot is the driving idea behind Keysight’s FieldFox microwave analyzers. They’re
equipped to handle routine maintenance, in-depth troubleshooting and anything in
between. Better yet, FieldFox delivers Keysight-quality microwave measurements wherever you need to go. Add FieldFox to your kit and carry precision with you.
Related literature
FieldFox Handheld Analyzers, Brochure
FieldFox Spectrum Analyzers, Technical Overview
FieldFox Vector Network Analyzers, Technical Overview
FieldFox Handheld Analyzers, Data Sheet
FieldFox Handheld Analyzers, Coniguration Guide
FieldFox N9912A RF Analyzer, Technical Overview
FieldFox N9912A RF Analyzer, Data Sheet
FieldFox N9923A RF Vector Network Analyzer, Technical Overview
FieldFox N9923A RF Vector Network Analyzer, Data Sheet
Publication number
5990-9779EN
5990-9782EN
5990-9781EN
5990-9783EN
5990-9836EN
5989-8618EN
N9912-90006
5990-5087EN
5990-5363EN
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s commitment to superior product quality and lower total cost
of ownership. The only test and measurement company with three-year
warranty standard on all instruments, worldwide.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to five years of protection and no budgetary surprises to ensure your
instruments are operating to specification so you can rely on accurate
measurements.
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008
Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
55 11 3351 7010
001 800 254 2440
(800) 829 4444
Asia Paciic
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
0124 229 2010
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 6375 8100
Europe & Middle East
Austria
Belgium
Finland
France
Germany
Ireland
Israel
Italy
Luxembourg
Netherlands
Russia
Spain
Sweden
Switzerland
United Kingdom
0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-02-06-15)
www.keysight.com/find/fieldfox
This information is subject to change without notice.
© Keysight Technologies, 2014, 2015
Published in USA, March 6, 2015
5990-9780EN
www.keysight.com